WorldWideScience
1

Heart Valve Replacement  

Medline Plus

X-Plain Heart Valve Replacement Reference Summary Introduction Sometimes people have serious problems with their heart valves. A heart valve repair or ...

2

Prognostic implications of pulmonary hypertension in patients with severe aortic stenosis  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...

2011-01-01

3

Total prosthetic replacement of atrioventricular valves in the dog  

UK PubMed Central (United Kingdom)

The metal parts of cardiac valve prostheses cause reactions in the surrounding tissues of the heart. In some dogs rather abnormal reactions were found, and were attributed to corrosion of the stainless...Full Text Available

1972-01-01

4

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic ...

2009-04-15

5

Percutaneous mitral valve repair: the beginning of the end or the end of the beginning?  

UK PubMed Central (United Kingdom)

The new percutaneous mitral valve repair techniques are at an early stage. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary...Full Text Available

6

On the Improved Plasma Confinement in Toroidal Systems. Measuring of the Plasma Density Inhomogeneities Near the Gas Valve  

International Nuclear Information System (INIS)

Comparison of plasma density increase was carried out in outer and inner channels of the interferometer in T-11M tokamak. There were two cases of gas puffing: by outer valve or upper one. Amplitude of difference of the plasma density increase consisted of 9% near the outer valve. Perturbation of the electric potential e?1/Te can have similar value. This perturbation can lead to appearance of the additional losses.

2006-01-01

7

Chylopericardium after cardiac surgery can be treated successfully by oral dietary manipulation: a case report  

UK PubMed Central (United Kingdom)

We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available

8

Freeze protection valve and system  

Energy Technology Data Exchange (ETDEWEB)

The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.

1985-12-10

9

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. ...

10

An analysis and evaluation of differential pressure calculation of motor operated valve using system flow model  

Energy Technology Data Exchange (ETDEWEB)

As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.

1999-11-01

11

Flow characteristics and dynamics of swing check valves in compressible flow applications (Part-1)  

Energy Technology Data Exchange (ETDEWEB)

In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle vs. mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements in compressible flows. This paper presents results of steady compressible flow testing of an NPS 4 swing type check valve in air. Mean flow velocities vs. ...

1996-12-01

12

Effects of compressibility on flow characteristics and dynamics of swing check valves. Part 1  

Energy Technology Data Exchange (ETDEWEB)

In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle versus mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements involving fluids of relatively higher compressibility. This paper presents results of steady flow testing of an NPS 4 swing-type check valve in air. Mean ...

1997-05-01

13

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive ...

1995-09-01

14

Evaluation of the flow forces on a direct (single stage) proportional valve by means of a computational fluid dynamic analysis  

International Nuclear Information System (INIS)

The aim of this paper is to investigate the fluid dynamic behaviour of a commercial hydraulic proportional valve in order to evaluate and justify its global performances and, in particular, to analyze the effects of some additional design features on the reduction of the force required to maintain the valve open. The proposed analysis has been performed by applying the commercial computational fluid dynamics (CFD) code, Fluent, to the solution of the three dimensional turbulent flow field through a circumferential sector of the entire valve for different spool strokes. The reliability of the employed modelization is demonstrated by the comparison between the computed flow rate curve and the corresponding experimental data provided by the manufacturer. With regard to the metering edge design, it is shown that the cylindrical hole provided on the top of the hemi-spherical notch to improve metering at ...

2007-03-01

15

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

16

TECHNICAL REPORT - NASA Technical Reports Server  

Science.gov (United States)

VORTEX VALVE FLOW CHARACTERISTICS. 49. VENTED VORTEX VALVE. 50. VORTEX DIVERTER VALVE- ... 46 AND VORTEX MIXING VALVE FLOW CHARACTERISTICS ...

17

Brazilian onshore pipelines rehabilitation program  

Energy Technology Data Exchange (ETDEWEB)

Brazil currently has an oil and transport system with approximately 15,000 km of pipeline. However, energy needs are now increasing due to rapid population growth and expanding industrial activities in the country. This paper provided details of a pipeline rehabilitation program conducted across 424 km of pipeline in northeastern Brazil. The pipeline crossed 32 municipal districts. Over 37 replacements and upgrades were completed as part of the rehabilitation program. Surveys were completed to verify depth of pipeline cover, as well as to examined the condition of the external pipe coating, and the operational status of the cathodic protection (CP) system. Shutdown of the pipeline was completed during a 14 hour period, and included depressurization, cutting work, welding, and repressurization. Services included pigging to evaluate pipe-wall thickness; corrosion section replacement; an investigation of class locations during the operating life ...

2004-07-01

18

Freeze protection valve for solar heaters  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway ...

1987-07-21

19

Thermal analysis of spent fuel in rehearsal and emergency storage facility (RESF) under station blackout (SBO) in TAPS - 4  

International Nuclear Information System (INIS)

The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the ...

2006-11-13

20

RESEARCH STUDY OF THE VORTEX VALVE FOR - NASA Technical Reports Server  

Science.gov (United States)

Vortex Valve Flow Characteristics. Basic Circuit Schematic. System Test Installation. Flight-Weight Design of SITVC System. Staged Vortex Valve SITVC ...

21

//s /~7 - NASA CR-  

Science.gov (United States)

Valve Flow Characteristics. 3-68. 3-40. Valve Operating Current Vs. Temperature ...... VALVE FLOW CHARACTERISTICS. Acceptance Test 4/29/74. SINs 002 & 004 ...

22

Computerized pressure monitoring and control of Hydro-Quebec`s fluid-filled high-voltage underground cable network in Montreal  

Energy Technology Data Exchange (ETDEWEB)

The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management tools. 1 ref., 1 tab., 4 figs.

1996-08-01

23

Study of the properties of in-situ sodium activated and organomodified bentonite clay - SBR rubber nanocomposites - part II: Physical property  

British Library Electronic Table of Contents (United Kingdom)

In-situ sodium activated organo modified bentonite clay was also used for partial replacement of the carbon black (N330). Detailed study with the black filled compound revealed that, with slight modification of the curing package, up to 10 phr of the carbon black replacement is possible. At equivalent loading of 5 and 10 phr of in-situ sodium activated organo modified bentonite clay exhibited better properties in comparison to carbon black filled compound.

2010-01-01

24

Evolution of ASTEC V1.2 rev.1 code for WWER-1000 reactors/SBO sequence  

International Nuclear Information System (INIS)

In this paper a comparison between calculations of severe accidents occurred from WWER-1000 with ASTEC code specified for an event of full unloading with relief valves stuck opened with no hydroaccumulators intervention is presented. The purpose of the analyses provided is to present the relationship between the improvements of the actual version (ASTEC Vl.2 rev. 1) and ASTEC V1.1 p2 like: code modifications, incoming data improvements. Such discrepancies are to be examined. Case by case suggestions for ASTEC improvements are to be provided.

2006-06-14

25

The French design code: RCC-M status and on-going developments  

International Nuclear Information System (INIS)

Since 1978, an important effort has been on-going between Framatome and Electricite de France (EDF) to develop and update technical rules for the design and construction of nuclear power plants. Two design codes are developed, one for PWRs: RCC-M and one for FBRs: RCC-MR. After some comments on the organization of RCCM Commission, the paper presents: (1) the major differences with the ASME Section III Code for fatigue, plastic shakedown and rupture analysis; (2) the review of some important facts in terms of availability or maintenance costs (in-service inspection, replacements, repairs, etc.) of operating plants like underclad cracking, stratification, CRDM nozzles, cast elbows, steam generator tubes, etc.; (3) how can one take into consideration this operating feedback in RCC-M Code; and (4) few examples of major on-going developments for fracture analysis on different components and fatigue analysis of valves. In conclusion, the ...

1996-07-21

26

Study of the properties of in-situ sodium activated and organomodified bentonite clay - SBR rubber nanocomposites - Part I: Characterization and rheometric properties  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a detailed characterization and rheometric property study of in-situ sodium activated, organomodified bentonite clay - styrene-butadiene rubber (SBR) nanocomposite. It was found that around 10phr loading was the optimum level for maximum effect of the organo clay. The WAXD data indicated that at higher loading there was formation of agglomerations in the matrix. It was found that organo clay compound exhibited lower maximum torque in comparison to equivalent amount of carbon black loaded compound. The nanocomposites were also used for partial replacement of N330 carbon black in a highly black loaded compound. Part replacement of the carbon black with nano-clay reduced the maximum rheometric torque in comparison to the control compound. Detail study revealed that with sl...

2010-01-01

27

Summary of ACSL Simulations of the MSRE Auxiliary Charcoal Bed Vacuum System  

Energy Technology Data Exchange (ETDEWEB)

The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance acceptable; (1) Remove valve PCV4. (2) Modify the flow controllers ...

2000-10-26

28

A study on modelling of a butterfly-type control valve by a pneumatic actuator  

Energy Technology Data Exchange (ETDEWEB)

This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.

2009-07-01

29

Improved detection of myocardial infarction with technetium-99m stannous pyrophosphate and serum MB creatine phosphokinase  

International Nuclear Information System (INIS)

The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK activity. Serum MB CPK activity increased after cardiac surgery in 6 patients undergoing ...

30

Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event  

International Nuclear Information System (INIS)

In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle heat transfer model, decay heat model and ...

2001-10-01

31

In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves  

DEFF Research Database (Denmark)

BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native ...

2010-01-01

32

Preliminary Fabry Perot testing - 1986  

Science.gov (United States)

Fabry Perot interferometry is a method of determining instantaneous velocities of an object in motion. The interferometer system is composed of the Fabry Perot interferometer, a laser, an electronic streak camera, and several focusing lenses. The first tests discussed were done on exploding bridgewire devices. During these tests, several system parameters were changed. These changes did not seem to affect the data, which appeared to be consistent. The second tests performed focused on slapper-type devices. It was determined that sandblasted, vapor-deposited aluminum on the slapper material would be required to yield quality data. Streak camera failure prevented much data from being collected. An effort is being made to replace the current streak camera. After it is replaced, a Fabry Perot and velocity interferometry system for any reflector comparison will be made. The results will be published as the conclusion to this ...

1987-04-30

33

Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve  

UK PubMed Central (United Kingdom)

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available

2010-06-28

34

Optimization of Valve Disc Using Orthogonal Array and Kriging Model  

Science.gov (United States)

A butterfly valve is a type of flow control device, typically used to regulate a fluid flowing. Currently, FEA is often used to predict the safety in the design of valve disc. Also, the study about the affection of butterfly valve's disc to the valve flow characteristics by using CFD has been done by many researchers. Along with the development of computer technique, design and analysis of computer experiments has becoming more and more important in engineering design and optimization. Hereinto Kriging model is one popular analysis approach for the purpose of creating a cheap ``meta-model'' as a surrogate to a computationally expensive simulation model. In this paper, the numerical analysis considered the strength, pressure loss coefficient and weight of valve disc simultaneously is investigated to improve the shape of a traditional butterfly valve disc. ...

2008-10-01

35

Large scale steam valve test: Performance testing of large butterfly valves and full scale high flowrate steam testing  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned ...

1995-05-01

36

Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants  

International Nuclear Information System (INIS)

This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV ...

1992-07-01

37

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a ...

38

Technical Lio - NASA Technical Reports Server  

Science.gov (United States)

Mod IE did not affect the valve flow characteristics. C. BIPROPELLANT -VALVE EVALUATION. 1. Ball and Shaft Seal Evaluation ...

39

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability  

CERN Document Server

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability

1989-01-01

40

Development of linear flow rate control system for eccentric butter-fly valve  

Energy Technology Data Exchange (ETDEWEB)

Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)

1999-12-01

41

Evaluation of a solid hydrophone cable  

Energy Technology Data Exchange (ETDEWEB)

In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage causes buoyancy loss and the need for immediate replacement. Salt water intrusion causes electrical ...

1982-07-01

43

Newly developed control and stop valves  

International Nuclear Information System (INIS)

... bwr type reactors closures fluidic control devices operation performance pwr

44

Electromagnetic fluid valve  

International Nuclear Information System (INIS)

... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic

46

Thermal-hydraulic analysis following a safety flapper valve's fault for a pool-type research reactor  

International Nuclear Information System (INIS)

One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)

47

Recycling flow control device for a nuclear reactor  

International Nuclear Information System (INIS)

Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and ...

48

An experimental study on stable flow control for multi-stage expansion device  

Energy Technology Data Exchange (ETDEWEB)

An Experimental study was performed to investigate flow characteristic of multi-stage expansion valve applied with inverter heat pump. Multi-stage expansion consists of parallel valve which is controlled on/off type of solenoid valve. Expansion valve open one solenoid the other closed in low frequency region and open two solenoid valve in high frequency region. In rated frequency region always open one solenoid valve and control period and on-off time ratio for the other solenoid valve. Flow characteristics of a orifice expansion was measured as a function of orifice diameter and operating conditions. As a results multi-stage expansion device can control a stable flow with period and on-off time ratio. (author). 4 refs., 7 figs., 1 tab.

1998-04-01

49

Linearization of Valve Flow Characteristics for Steam Turbine Control  

Energy Technology Data Exchange (ETDEWEB)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)

2009-10-15

50

Linearization of Valve Flow Characteristics for Steam Turbine Control  

International Nuclear Information System (INIS)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)

2009-10-01

51

Oil pipeline valve automation for spill reduction  

Energy Technology Data Exchange (ETDEWEB)

Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application ...

2003-07-01

52

Scintigraphical observation of femoral head in femoral neck fractures. Comparison with histological findings  

Energy Technology Data Exchange (ETDEWEB)

In 10 cases of femoral neck fracture treated with prosthetic replacement, the preoperative sup(99m)Tc-MDP scintigraphs were investigated and then compared with each histological findings of the extracted femoral head. The appearances of the scintigraphs were classified into following 3 patterns; increased activity pattern of sup(99m)Tc-MDP uptake in the overall femoral head (type I) in 4 cases, deficient activity pattern at the lateral side correspond to weight-bearing area (type II) in 2 cases and considerably deficient activity pattern in the whole femoral head (type III) in remaining 4 cases. Histological examination of the extracted femoral heads revealed the narrow part of ischemic necrosis in type I. However type II showed extensive necrosis in the portion of deficient activity by scintigraphs and in type III, the femoral heads except articular cartilage were entirely necrotic. This classification of sup(99m)Tc-MDP scintigraphy is correlated with the degree ...

1984-06-01

53

Loss of flow incident - Simulation and measurements in the MPR  

International Nuclear Information System (INIS)

As part of the Probabilistic Safety Analysis of the Multi Purpose Reactor, MPR, the list of Postulated Initiating Events was analyzed and one of these PIEs corresponds to the Loss of Coolant Flow. It is well known that during the operation life of a research reactor a LOFA could eventually occur and, once this event takes place, in time detection and automatic actions, thanks to the engineering safety features of the system, will mitigate the incident evolution. The postulated event corresponds to a loss of flow due to a total loss of power supply. The goal of the present work is to provide a general description and the engineering safety features of the MPR, as well as describe the sequence of scenarios during a LOFA. Temporal evolution of main parameters is presented, also. During Stage A of the Commissioning Program measurements of the core cooling system pump coast-down were performed in order to validate previous simulation results, as well as, flap valves ...

1999-10-26

54

Evaluation of spark ignition of a gas cooktop flame  

Science.gov (United States)

One of the energy-saving devices used on gas cooking appliances to eliminate the standing pilot is a spark ignition system. For safety, an ignition system must start promptly and be active whenever flowing gas is not ignited. To minimize noise and nuisance shock hazard, ignition must occur quickly and the sparking must be stopped as soon as ignition occurs and remain off as long as the flame is present. To accomplish both of these requirements, ignition systems have been devised which use the electrical current rectification property of a flame to sense it. These systems spark whenever the gas valve is on and a flame is not present. The factors affecting the performance of a spark ignition system are numerous, complex, and transient. All of these properties make quantification of performance difficult. A system is described which can evaluate the overall performance of ignition systems over significant periods of time and varieties of operating conditions and ...

1996-01-01

55

Anterior Approach Total Hip Replacement  

Medline Plus

... of the Taperloc Microplasty stem and E-poly antioxidant-infused technology during a hip replacement through the ...

56

Selecting the right pumps and valves for flue gas desulfurization  

Science.gov (United States)

Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.

2006-07-15

57

Latent Tricuspid Valve Rupture after Motor Vehicle Accident and Routine Echocardiography in All Chest-Wall Traumas  

UK PubMed Central (United Kingdom)

Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available

2009-01-01

58

Heterotopic transcatheter tricuspid valve implantation: first-in-man application of a novel approach to tricuspid regurgitation  

UK PubMed Central (United Kingdom)

AimsTranscatheter treatment of heart valve disease is well established today. However, for the treatment of tricuspid regurgitation (TR), no effective catheter-based approach is...Full Text Available

2011-05-01

59

Cavitation guide for control valves  

Energy Technology Data Exchange (ETDEWEB)

This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of ...

1993-04-01

60

Observation of Fluorescence for some lanthanides in LiCl-KCl molten salt media at high temperature  

Energy Technology Data Exchange (ETDEWEB)

To our knowledge, the fluorescence studies of lanthanides in LiCl-KCl eutectic molten salt at a high temperature are not reported yet. The fluorescence of the lanthanide-ions was generally decreased when the temperature was increased. Moreover, the fluorescence of the lanthanides was strong when the sample was solidified to or from the melt. The temperature, where the fluorescence was decreased, was identified to be different depending on the species of the lanthanides and the substrates was considered to possibly be from quenching of the fluorescence due to either the collisions of melted samples induced by high temperature media or the re-absorption of fluorescence by the samples. Several comparison experiments were performed to explain and understand this phenomenon and improve the fluorescence. In this way, an on-line monitoring of chemical species and the concentration for lanthanides elements in molten salt media of pyrochemical process can be accomplished, ...

2008-08-15

61

Casimir repulsion beyond the dipole regime  

CERN Document Server

We extend a previous result [Phys. Rev. Lett. 105, 090403 (2010)] on Casimir repulsion between a plate with a hole and a cylinder centered above it to geometries in which the central object can no longer be treated as a point dipole. We show through numerical calculations that as the distance between the plate and central object decreases, there is an intermediate regime in which the repulsive force increases dramatically. Beyond this, the force rapidly switches over to attraction as the separation decreases further to zero, in line with the proximity force approximation. We demonstrate that this effect can be understood as a competition between an increased repulsion due to a larger polarizability of the central object interacting with increased fringing fields near the edge of the plate, and attractive forces due primarily to the nonzero thickness of the plate. In comparison with our previous work, we find that using the same plate geometry but ...

2011-01-01

62

A novel medium devoid of ruminant peptone for high yield growth of Mycoplasma ovipneumoniae  

British Library Electronic Table of Contents (United Kingdom)

Mycoplasma ovipneumoniae is considered an emerging veterinary pathogen causing pneumonia in sheep and goats worldwide. Currently it has not been possible to define a growth medium that yields the maximum growth of M. ovipneumoniae within a short incubation period. Growth yields of M. ovipneumoniae in Eatons medium are variable and not as consistently high as those seen with other Mycoplasma spp. This study investigated the ability of different M. ovipneumoniae field strains to grow in various media formulations, where PPLO broth was replaced by a vegetable protein source, and comparisons were made in terms of strain viability in Eatons medium. Studies were also conducted to determine the optimal carbohydrate source for use in the M. ovipneumoniae medium. Generally, it was found that differ...

2008-01-01

63

A cost of energy comparison of single and multi cavity solar central receiver systems  

Energy Technology Data Exchange (ETDEWEB)

Variations in thermal energy costs of single module solar central receiver systems using one, two, three, and four aperture cavity receivers at a location corresponding to Barstow, California are investigated for nominal power ratings ranging from 100 MWt to 900 MWt. Also considered are the effects on energy costs of changes in plant latitude, and the energy cost impact of the replacement of the single module design with multiple connected modules producing the same thermal power. The results, obtained with the aid of the DELSOL2 computer program, indicate that solar central receiver plant energy costs are insensitive functions of power level, latitude, and configuration. No clear cost of energy advantage between single and multiple modules is seen.

1983-06-01

64

Gunsof - NASA  

Science.gov (United States)

end of the barrel. The petal valve and ring seal are inserted behind it, and the gun barrel assembly and HP section are clamped together with hydraulic collars. ...

65

Evaluation of the fluid force in main feed water control valve for APWRs  

International Nuclear Information System (INIS)

... 2432 v. 43(1) SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

2006-01-01

66

Active Shimmy Control System  

Science.gov (United States)

... Both effects are undoubtedly caused by the ahaping of the spool valve flow characteristics The linear region of response corresponds to ...

1975-12-01

67

Effects on fatigue life of gate valves due to higher torque switch settings during operability testing  

Energy Technology Data Exchange (ETDEWEB)

Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond the scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and ...

1995-12-01

68

Dynamic performance testing of control valves  

International Nuclear Information System (INIS)

Response of control valves plays an important role in the dynamics of the flow system as a whole. Knowledge of its transfer function would facilitate analysis of the behaviour of the system. This paper presents the application of Levy's complex curve fitting method for determination of the transfer function of control valves used in Liquid Zone Control System of 540 MWe PHWR. (author)

2005-02-01

69

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

70

Linearization of Valve Flow Characteristics for Steam Turbine Control  

Energy Technology Data Exchange (ETDEWEB)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.

2009-05-15

71

Linearization of Valve Flow Characteristics for Steam Turbine Control  

International Nuclear Information System (INIS)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.

2009-05-01

72

Dynamic modelling of check valves in shipping terminals; Modelagem dinamica de valvulas de retencao em terminais maritimos  

Energy Technology Data Exchange (ETDEWEB)

As usual a shipping terminal contains a header and its diameter is smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves without dynamic modeling may introduce some error in the maximum pressure results without a dynamic model approach. The current paper uses commercial pipeline simulation software to model the dynamic behavior of the check valves. It was studied the header diameter influence and how the check valve model type may change the maximum pressure in the pipeline. It was proved that even a pipeline that works with low pressure and small elevation drop needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)

2005-07-01

73

Experimental parametric equation for the prediction of valve coefficient (C_v) for choke valve trims  

International Nuclear Information System (INIS)

The calculation of nominal choke valve size determines the effective capacity for an oil and gas production system. The degree of restriction for the controlling area in the valve is a function of the surrounding geometry. In an orifice plate this is known as the 'velocity of approach' and can be used to determine the meter coefficient (C_m). This paper presents a technique for choke valves, based on the meter velocity of approach parameter, which can be used to predict the Valve Coefficient (C_v) for new trim designs. The prediction method uses a data trend based on a number of flow tests conducted on various trim characteristics. The resultant parametric equation is used to predict the C_v of a new trim geometry. The method relies on experimental data determined per IEC 60534-2-3, with calculations per IEC 60534-2-1. This paper further investigates the effect of varying upstream geometry on C_v for a ...

74

Opportunistic replacement of fusion power system parts  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a maintenance problem in a fusion power plant. The problem is to specify which life limited parts should be replaced when there is an opportunity. The objective is to minimize the cost rate of replacement parts and of maintenance actions while satisfying a power plant availability constraint. The maintenance policy is to look ahead and replace all parts that will reach their life limits within a time called a screen. Longer screens yield greater system availabilities because more parts are replaced prior to their life limits.

1981-10-26

75

A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results  

UK PubMed Central (United Kingdom)

BackgroundHip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly...Full Text Available

76

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular ...

77

Embryonic Retinal Cells and Support to Mature Retinal Neurons  

UK PubMed Central (United Kingdom)

Purpose.There is a paucity of neuron replacement studies for retinal ganglion cells. Given the complex phenotype of these neurons, replacement of ganglion cells may be impossible....Full Text Available

2010-04-01

78

Development of new three way valve using vacuum for liquid transfer  

International Nuclear Information System (INIS)

The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)

2008-07-01

79

Training aids: the motor operator valve trainer  

International Nuclear Information System (INIS)

The spectrum of training aids used in the nuclear industry runs the gamut from the very basic (i.e., valve training aids - gate, globe, check) to the highly complex (i.e., nuclear full scope simulator). Designing and purchasing the best training aids take much time, detailed investigation, and good understanding of plant operations. The training aid that has given the New York Power Authority the best results has been the motor operator valve (MOV) trainer. Some of the items that make the MOV trainer a good choice are: (1) large number of MOVs in the plant, (2) importance of MOVs to safe plant operation, (3) detailed MOV procedures used by the plant, (4) history of MOV problems, and (5) ability to demonstrate important concepts and operation - hammer blow effect, torque and limit switch adjustment and functions, and actual sequence of operation of the limitorque valve operator.

1987-06-07

80

The National Shipbuilding Research Program Task S-20: A ...  

Science.gov (United States)

... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...

1979-05-01

81

Flow mapping for assessment of native and repaired valves  

International Nuclear Information System (INIS)

Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.

82

Control rod drives  

International Nuclear Information System (INIS)

Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the ...

84

3 - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011... properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. ...

85

Report on commissioned business for fiscal 1997. Development of new power storage system for cells and development of technology for distributed power storage (research for a zinc/air cell system for automobiles); 1997 nendo itaku gyomu hokokusho. Shingata denchi denryoku chozo system kaihatsu bunsangata denryoku chozo gijutsu kaihatsu (denki jidoshayo aen kuki denchi system chosa)  

Energy Technology Data Exchange (ETDEWEB)

Concerning the above, it is discussed whether such a system is feasible in Japan. A zinc/air cell system requires some special plants for zinc regeneration, etc. It is necessary to build a zinc refining plant and to install dozens of electrode replacing facilities in an area dozens of kilometers in diameter with the plant at the center. For such a system to be functional, there have to be several tens of thousands of automobile users in a limited area. In Japan, so large a number will not be found anywhere even if the appeal is directed to those in the postal service and electric utilities. There will be no economic success in Japan, different from in Germany. As for the economic comparison between a zinc/air cell system and natural gas system, the two will be equivalent to each other as far as the use of the quick filling stations for the natural gas automobiles remains as it is. When the number in consideration is so large as several tens of ...

1998-03-01

86

Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor  

Energy Technology Data Exchange (ETDEWEB)

Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel design, the heat exchanger efficiency ...

2005-07-01

87

Design improvements and operational experience of programmable digital comparator system  

International Nuclear Information System (INIS)

Application of Programmable Digital Comparator System (PDCS) in NPP is to monitor large number of plant parameters and generate contact outputs for reactor trip, reactor setback, process interlocks etc. when parameters cross their operational bounds. Till NAPS these functions are achieved through individual Indicating Alarm Meters (IAM). PDCS used for the first time in KAPS replaces these IAMs. Since its inception, PDCS has undergone improvements in design, incorporates additional functionalities/enhanced features. Dedicated PDCS is provided in TAPP-3 and 4 for protection function. System re-configurability, on-line inter channel comparison of safety critical process parameters' values, Graphic User Interface etc. are other enhancements. From KAPS to TAPP-4 system has given many years of almost trouble-free operation. Commissioning of TAPP-3 system has been very smooth. Objective of the paper is to describe the advantage of the new system, its ...

2006-11-13

88

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS ...

1995-08-01

89

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS ...

1995-01-01

90

Additive effects common to radiation grafting and wood plastic composite formation  

Energy Technology Data Exchange (ETDEWEB)

A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium salts, multifunctional ...

1996-08-01

91

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel: In natural convection dominated flow regimes  

Energy Technology Data Exchange (ETDEWEB)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated in the natural convection dominated region for a wide range of Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.02 {<=} w{sub in} {<=} 0.025 m/s) using a flow rate control valve so that Reynolds number was always about Re = 250. Experiments were conducted for modified Rayleigh numbers 3 x 10{sup 7} < Ra{sup *} < 6 x 10{sup 8} and Richardson number ...

2009-10-15

96

Use of endobronchial one-way valves reveals questions on etiology of spontaneous pneumothorax: report of three cases  

UK PubMed Central (United Kingdom)

Spontaneous pneumothoraces are believed to arise when air from the supplying airway exit via a ruptured visceral pleural bleb into the pleural cavity. Endobronchial one-way valves (EBVs) allow air exit...Full Text Available

97

Studies of neural networks for engine control: application to the electromechanical valves engine; Etudes des reseaux de neurones pour le controle moteur: application a soupapes electromecaniques  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)

1997-12-31

98

Multilayer structures with giant magnetoresistance  

International Nuclear Information System (INIS)

The phenomenological description of the giant magnetoresistance effect as well as discussion of the requirements which must be fulfilled in giant magnetoresistance thin film structures are given in the first part of our review. In the second part the magnetization reversal and giant magnetoresistance effect of antiferromagnetically coupled multilayers, spin Valve and pseudo-spin valve thin film structures are explained. For these structures we also discuss the influence of the structure defects such as surface roughness and pinholes on the giant magnetoresistance effect. (author)

2001-09-23

99

Hydraulic device for control rod drive mechanisms  

International Nuclear Information System (INIS)

Purpose: To improve the reliability of control rod drive mechanisms for use in BWR type reactors by preventing erroneous insertion of control rods caused by the increase in the coolant pressure. Constitution: A pressure-releaf valve mechanism is provided which opens its valve when a detected difference between the pressure of the coolants flowing through coolant pipeways and the reactor pressure exceeds a predetermined pressure difference. If the coolant pressure increases abnormally, coolants in the coolant pipeway are released to lower the pressure. (Aizawa, K.).

1981-07-31

100

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography  

UK PubMed Central (United Kingdom)

AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available

2008-10-01

101

Use of explosive quick depressurization valves in the SBWR project. Dynamic loads induced by their operation  

International Nuclear Information System (INIS)

In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...

102

Comparison and validation of two high-resolution weather forecast models at Frankfurt Airport  

Energy Technology Data Exchange (ETDEWEB)

In recent years the 'Nowcasting Wake Vortex Impact Variables' model NOWVIV has been developed at the Deutsches Zentrum fuer Luft- und Raumfahrt, DLR, to forecast weather parameters in airport environments. The German Meteorological Service, DWD, employs his COSMO-DE model (COnsortium for Small scale Modelling-DEutschland) for operational forecasts in Germany. A systematic comparison of model output from NOWVIV and a derivate of COSMO-DE, named COSMO-FRA, is presented. Both models are centred at Frankfurt Airport with horizontal resolutions of 2.1 km and 2.8 km, respectively. In the DLR Project Wetter and Fliegen the COSMO-FRA model will replace the NOWVIV model and become a key component in the future rapid update cycle for adverse weather predictions at the airports of Frankfurt and Munich. The forecast vertical profiles of runway crosswind, head/tail wind, temperature, and turbulent kinetic energy (TKE) are validated against ...

2009-10-15

103

Optimising the flow characteristic of a coke-oven flue-gas valve by means of Computational Fluid Dynamics (CFD); Stroemungsoptimierung eines Abgasventils von Koksoefen durch Computational Fluid Dynamics (CFD)  

Energy Technology Data Exchange (ETDEWEB)

In coke-oven operations flue-gas valves are used to switch the regenerator function from rich gas firing to lean gas firing. Compared with the simple geometry of the other parts of the flow path, which comprise flues and regenerators, the narrow and winding passages of the flue-gas valves give rise to relatively high losses in pressure. Without the construction of high (and therefore expensive) chimneys, this means that operating problems may well arise due the inadequate suction capacity. The project focused on the theoretical and experimental analysis of a coke-oven flue-gas valve. The primary aim was to reduce the pressure drop through the valve without modifying its external geomerty. The internal flow characteristics created by different valve geometries under a variety of operating conditions were simulated using the commercial CFD code Fluent/UNS, which provided velocity and ...

1999-06-01

104

Surge pressure behavior in reduced diameter segments of shipping terminals; Comportamento de pulsos de pressao em trechos de diametro reduzido de dutos de terminais maritimos  

Energy Technology Data Exchange (ETDEWEB)

In a shipping terminal, the pipeline in the pier usually has a diameter smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves placed in the pier may introduce some error in the maximum pressure when it was modeled in a conventional fashion. The dynamic check valve model had been added to a commercial pipeline simulation software and the results was compared with a similar model using the method of characteristics. Considering a real state shipping terminal case, it was proved even a pipeline that works with low pressure and smooth elevation profile needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)

2004-07-01

105

Modeling of a self-excited pulse combustor and stability analysis  

British Library Electronic Table of Contents (United Kingdom)

The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...

2011-01-01

106

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to the reference level and the possibility ...

1981-11-18

107

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).

1981-11-12

108

FIELD CORROSION TESTS FOR COMPARISON OF ...  

Science.gov (United States)

... Accession Number : ADD457408. Title : FIELD CORROSION TESTS FOR COMPARISON OF CORROSIVITY IN JAPAN AND CHINA. ...

109

Proposal for the award of a contract, without competitive tendering, for the replacement of lift machine room equipment and the installation of remote monitoring systems  

CERN Document Server

Proposal for the award of a contract, without competitive tendering, for the replacement of lift machine room equipment and the installation of remote monitoring systems

2011-01-01

110

Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury  

UK PubMed Central (United Kingdom)

IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available

2009-01-01

111

Clinical review: Patency of the circuit in continuous renal replacement therapy  

UK PubMed Central (United Kingdom)

Premature circuit clotting is a major problem in daily practice of continuous renal replacement therapy (CRRT), increasing blood loss, workload, and costs. Early clotting is related to bioincompatibility,...Full Text Available

2007-01-01

112

Changes in Tetracycline Susceptibility of Enteric Bacteria following Switching to Nonmedicated Milk Replacer for Dairy Calves?  

UK PubMed Central (United Kingdom)

A randomized intervention study was conducted to determine if discontinuing use of calf milk replacer medicated with oxytetracycline results in increased tetracycline susceptibility in Salmonella...Full Text Available

2008-06-01

113

Keratoconus: Frequently Asked Questions  

Science.gov (United States)

... a new cornea? As many of you know stem cell research and efforts to develop a replacement cornea have ...

114

Diffusion Zink Planting of Steels  

International Science & Technology Center (ISTC)

Research on Diffusion Zinc Cladding of Structural Steels, as Well as Their Mechanical and Corrosion Properties to Replace Their Cyanic Cadmium Plating

116

CARBON DIOXIDE REDUCTION SYSTEM  

Science.gov (United States)

... be easily replaceable, and its compartment or container ... in a simple, efficient manner for storage or disposal. ... and enters the reactor at approximatel ...

1963-01-01

117

Relationships of valve histology and mitochondrial and myofibril volume densities to hypertrophy of copper-deficient rat hearts  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four male weanling rats were fed either copper-adequate or -deficient diets until 9 or 11 weeks of age. Deficient rat hearts had increased mitochondria: myofibril compared to adequate rats. Eleven week old deficient rat hearts had decreased mitochondria: myofibril as the hearts increased in weight, but the larger hearts had greater myofibril volume densities. Cardiac mitochondria of deficient rats appeared vacuolated with fragmented cristae and translucent matrix. Valves from copper deficient rats appeared to have less connective tissue and were fragmented in areas. For deficient rats, heart:body weights of 9 wk old rats were negatively correlated with bicuspid valve pathology scores, whereas tricuspid valve scores from 11 wk old rats were negatively correlated with myofibril volume densities. These data suggest that the enlargement of the copper-deficient rat heart is due to: larger (1) mitochondria and (2) ...

1991-03-15

118

Primary coolant depressurization facility  

Energy Technology Data Exchange (ETDEWEB)

In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible ...

1992-10-14

119

Platelet thrombosis in cardiac-valve prostheses  

International Nuclear Information System (INIS)

The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue ...

1989-06-08

120

Malfunction of a Heimlich flutter valve causing tension pneumothorax: case report of a rare complication  

UK PubMed Central (United Kingdom)

BackgroundThoracic injuries play an important role in major trauma patients due to their high incidence and critical relevance. A serious consequence of thoracic trauma is pneumothorax,...Full Text Available

121

Lower Urinary Obstruction in Infancy  

UK PubMed Central (United Kingdom)

This paper reviews 165 cases of lower urinary obstruction in infancy. The commonest lesions were posterior urethral valves (91) and ectopic ureterocele (34), stenosis or atresia of the urethra (8),...Full Text Available

1972-04-01

122

Hydraulic system for driving control rods  

International Nuclear Information System (INIS)

Purpose: To enable safety reactor shut down upon occurrence of an abnormal excess pressure in a hydraulic control unit. Constitution: The actuation pressure for a pressure switch that generates a scram signal is set lower than the release pressure set to a pressure release valve. Thus, if the pressure of nitrogen gas in a nitrogen container increases such as upon exposure of the hydraulic control unit to a high temperature, the pressure switch is actuated at first to generate the scram signal and a scram valve is opened to supply water at high pressure to control rod drives under the driving force of the nitrogen gas at high pressure to rapidly insert the control element into the reactor and shut down it. If the pressure of the nitrogen gas still increases after the scram, the pressure release valve is opened to release the nitrogen gas at high temperature to the atmosphere. Since the scram is attained before the actuation ...

1980-11-07

123

EDF's experience in the operation of pump-storage plants  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.

1992-01-01

124

Double-Valve Libman-Sacks Endocarditis Causing Ventricular Fibrillation Cardiac Arrest  

UK PubMed Central (United Kingdom)

Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available

2011-01-01

125

Development of new decompression brake for large diesel engine. Part 2. Evaluation on durability and reliability; Ogata diesel engine yo shingata asshukuatsu kaihoshiki brake no kaihatsu. 2. Taikyu shinraisei no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This report deals with the establishment of durability and reliability for the new type decompression brake system for large diesel engines. By testing engines on the bench, it has been found that the cylinder pressure, with the cylinder at the compression stroke upper dead center, imposed on the exhaust valve bevel section during brake operation constitutes the maximum load on the valve train system, that the cylinder pressure, with the cylinder at the compression stroke upper dead center, rises in proportion to a rise in the engine rpm, and that the load on the valve train system is at its maximum when the exhaust valve opens by brake operation. By examining the conditions whereunder a real vehicle was allowed to run, it has been found that the brake is applied approximately four times more often when the vehicle runs in a city area than on an expressway and that when running on the expressway the ...

1995-04-20

126

Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT): a non-surgical method of lung volume reduction  

UK PubMed Central (United Kingdom)

BackgroundLung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently,...Full Text Available

127

Decrease in dust content and removal of sludge during drilling ascending shafts in coal  

Energy Technology Data Exchange (ETDEWEB)

Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.

1983-01-01

128

40 CFR 63.322 - Standards.  

Science.gov (United States)

...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...

2009-07-01

129

Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods  

Energy Technology Data Exchange (ETDEWEB)

Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.

1996-12-31

130

Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A  

Energy Technology Data Exchange (ETDEWEB)

Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

1986-10-01

131

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

132

A study on the optimal replacement periods of digital control computer's components of Wolsung nuclear power plant unit 1  

International Nuclear Information System (INIS)

Due to the failure of the instrument and control devices of nuclear power plants caused by aging, nuclear power plants occasionally trip. Even a trip of a single nuclear power plant (NPP) causes an extravagant economical loss and deteriorates public acceptance of nuclear power plants. Therefore, the replacement of the instrument and control devices with proper consideration of the aging effect is necessary in order to prevent the inadvertent trip. In this paper we investigated the optimal replacement periods of the control computer's components of Wolsung nuclear power plant Unit 1. We first derived mathematical models of optimal replacement periods to the digital control computer's components of Wolsung NPP Unit 1 and calculated the optimal replacement periods analytically. We compared the periods with the replacement periods currently used at Wolsung NPP Unit 1. The periods used ...

1993-01-01

133

Safe ageing management of nuclear power plants: An European synthesis  

International Nuclear Information System (INIS)

Ageing of nuclear power plants means evolution of material or equipment properties on one side, and evolution of personnel skill and procedure adequacy on the other side, both of which, after a certain time, may not be compatible with the required safety provisions, or with an economic operation of the plant. Repair or replacement of components, as well as change in service conditions for a better compatibility with component reduced capabilities can be used to mitigate ageing effects. The paper summarises the results of a study conducted in this field with the support of the European Commission. It presents: the synthesis of the work done under international auspices, and in the European context; the comparison of ageing management approaches used in several European countries with international recommendations; the summary of the various potential phenomena and their governing parameters, the methods of in-service ageing identification and ...

2002-11-04

134

Primary structures of four trypsin inhibitor E homologs from venom of Dendroaspis angusticeps: structure-function comparisons with other dendrotoxin homologs.  

Science.gov (United States)

Four trypsin inhibitor homologs, the first known from Dendroaspis angusticeps venom, were characterized using a combination of gel filtration, cation exchange, reverse-phase liquid chromatography, Edman degradation and mass spectrometry. The four toxins comprise two 57 residue and two 59 residue isoforms. The long toxins possess a Lys-Gln N-terminal extension lacked by the short toxins. The only other structural difference is an Arg/His replacement at position 55. The long Arg55 variant is identical to trypsin inhibitor E from the venom of Dendroaspis polylepis. The name epsilon-dendrotoxin is suggested so as to follow the nomenclature of Benishin, C.G., Sorensen, R.G., Brown, W.E., Krueger, B.K., Blaustein, M.P., 1988. Four polypeptide components of green mamba venom selectively block certain potassium channels in rat brain synaptosomes. Mol. Pharmacol. 34, 152-159. Among snake venom protease inhibitors, the epsilon-dendrotoxins are structurally most like the ...

2002-03-01

135

Nephrogenic systemic fibrosis after application of gadolinium-based contrast agents - a status paper; Nephrogene systemische Fibrose nach Anwendung gadoliniumhaltiger Kontrastmittel - ein Statuspapier zum aktuellen Stand des Wissens  

Energy Technology Data Exchange (ETDEWEB)

Recently the association of a rare disease named ''nephrogenic systemic fibrosis'' (NSF) with the administration of gadolinium-containing contrast media, especially gadodiamide (Omniscan, GE-Healthcare), was described. NSF is a scleroderma-like disease characterised by widespread tissue fibrosis. Until now, NSF cases were observed only in patients with kidney disease. Almost all patients were suffering from chronic renal insufficiency, 90 % of them required renal replacement therapy. The true incidence of the disease is unknown. First retrospective analyses of selected collectives of patients with end-stage renal disease showed 2 - 5 % cases of NSF after administration of Gadolinium-containing contrast agents with an odds ratio of 20 - 50 in comparison to non-exposed controls. NSF is a serious adverse reaction, which may result in severe disabilities and even death. Therefore all radiologists applying ...

2007-06-15

136

Future needs and requirements for AMS "1"4C standards and reference materials  

International Nuclear Information System (INIS)

"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth International Radiocarbon ...

2004-08-01

137

Evaluation of a novel radiopacifiying agent on the physical properties of surgical spineplex.  

Science.gov (United States)

Polymethlylmethacrylate (PMMA) is the most frequently used cement for percutaneous vertebroplasty and kyphoplasty. To aid visualisation during surgery cements are doped with radiopacifying agents such as Barium sulphate (Ba(2)SO(4)) or Zirconium Dioxide (ZiO(2)). Mounting research suggests that these agents may impair the biocompatibility of the cements. However, incorporating an alternative radiopacifier agent with excellent biocompatibility would be a significant step forward. Bioactive radiopaque glasses incorporating elements such as strontium (Sr) and zinc (Zn), known to have beneficial and therapeutic effects on bone, are of great interest in this respect. In this study, the Ba(2)SO(4) of the commercially available Spineplex was incrementally replaced with a radiopaque therapeutic glass composition. The resulting effects on cement setting time, peak isotherm, ultimate compressive strength, Young's modulus (up to 30 days cement maturation) and radiopacity were ...

2009-08-18

138

Development requirements for absorption processes for effective CO{sub 2} capture from power plants  

Energy Technology Data Exchange (ETDEWEB)

Effective commercial liquid absorption technology currently applicable for CO{sub 2} capture from power plant flue gases uses a conventional chemical solvent, MEA(monoethanolamine), which was developed over 60 years ago as general non selective solvent to remove acid gases from natural gas streams. The application to CO{sub 2} capture from almost atmospheric pressure flue gases required modification of the technology on account of the oxygen content to incorporate inhibitors to resist solvent degradation and equipment corrosion, as well as upstream treatment of the flue gases to remove both SO{sub x} and NO{sub x} present. The solvent strength used by such processes is relatively low in comparison with high strength modern chemical solvents. The resultant effect is large equipment and high regeneration energy requirements which is a parasitic load on the power plant. Using current technology for CO{sub 2} capture from flue gas derived from conventional pulverized ...

1997-12-31

139

Comparative tissue distribution and excretion of orally administered ["3H]diacetoxyscirpenol (anguidine) in rats and mice  

International Nuclear Information System (INIS)

A quantitative comparison of tissue distribution and excretion of an orally administered sublethal dose of [3H]diacetoxyscirpenol (anguidine) was made in rats and mice 90 min, 24 hr, and 7 days after treatment. Total recoveries of 95-100% were obtained. Approximately 90% of the dose was excreted in urine and feces during the first 24 hr with a feces:urine ratio of about 1:4.5 in both species. Carcass and tissue radioactivity dropped rapidly during the first 24 hr but remained relatively constant at low, but detectable, levels over the course of the experiment. Few substantive interspecies differences were noted in tissue distribution. At 90 min the highest percentage of dose was in tissues involved in sequestering diacetoxyscirpenol because of high body water/lipid content or the absorption, metabolism, or excretion of the toxin. The rank order of these tissues was generally stable over the course of the experiment. When data were expressed as specific ...

143

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations  

International Nuclear Information System (INIS)

The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam quality, the following set of clinically relevant dose-volume values was reported: (i) minimal, median, ...

2006-09-01

144

Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable ...

2006-11-13

145

Remote replacement of TF (toroidal field) and PF (poloidal field) coils for the compact ignition tokamak  

Energy Technology Data Exchange (ETDEWEB)

The use of deuterium-tritium fuel in the Compact Ignition Tokamak will require applying remote handling technology for ex-vessel maintenance and replacement of machine components. Highly activated and contaminated components of the fusion devices auxiliary systems, such as diagnostics and RF heating, must be replaced using remotely operated maintenance equipment in the test cell. In-vessel remote maintenance included replacement of divertor and first wall hardware, faraday shields, and for an in-vessel inspection system. Provision for remote replacement of a vacuum vessel sector, toroidal field coil or poloidal field ring coil was not included in the project baseline. As a result of recent coil failures experienced at a number of facilities, the CIT project decided to reconsider the question of remote recovery from a coil failure and, in January of 1990, initiated a coil replacement ...

1990-01-01

146

Replacement of bearing journals on heat transport pumps at the Wolsung nuclear generating station  

International Nuclear Information System (INIS)

The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.

1987-11-22

147

Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test  

Energy Technology Data Exchange (ETDEWEB)

Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.

2008-10-15

148

Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test  

International Nuclear Information System (INIS)

Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.

2008-10-01

149

Liquid zone system events at Wolsong Unit 2  

International Nuclear Information System (INIS)

On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) ...

1998-09-07

150

Dynamic load in suppression pool during BWR main steam safety relief valve actuation  

International Nuclear Information System (INIS)

BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure with jet deflector were installed. The test plan and the test result with an actual ...

1979-01-01

151

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable ...

1986-06-09

152

SPACEWARN Bulletin 682 - the NSSDC! - NASA  

Science.gov (United States)

Oct 1, 2010 ... AEHF 1 is the first of four Advanced Extremely High Frequency (AEHF) satellites that will replace the earlier Milstar system. The AEHF ...

153

REVIEW OF EXPLOSIVE (CHEMICAL) FORMING  

Science.gov (United States)

... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...

1965-04-01

154

Prestin and high frequency hearing in mammals  

UK PubMed Central (United Kingdom)

Recent evidence indicates that the evolution of ultrasonic hearing in echolocating bats and cetaceans has involved adaptive amino acid replacements in the cochlear gene prestin. A substantial...Full Text Available

2011-03-01

155

Malaspina University-College's green building strategy  

Energy Technology Data Exchange (ETDEWEB)

This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance ...

2000-01-01

156

FR Doc 2010-24310  

Science.gov (United States)

and used to reduce or replace petroleum-based transportation fuel, heating oil or jet fuel). In addition, this rule includes a new regulatory provision establishing a...

2010-09-27

157

Cryogenic trick for enhanced cooling using liquid nitrogen  

International Nuclear Information System (INIS)

The thermal transpiration method has been employed to replace the temperature of liquid nitrogen by #approx#12 K. This is done by bubbling He (g) through the liquid nitrogen.

1993-01-01

158

Coast Guard. Challenges Affecting Deepwater Asset ...  

Science.gov (United States)

... Deepwater Program is a 25-year, $24 billion plan to replace or modernize its fleet of vessels, aircraft, and information management capabilities. ...

2007-06-01

159

BIG BEAR SOLAR OBSERVATORY - NASA Technical Report Server (NTRS)  

Science.gov (United States)

replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...

160

Army Communicator. Volume 32, Number 2, Spring 2007  

Science.gov (United States)

... Introduction to the Signal Regiment Cisco Academy 1-4 (CCNA) Engineering Math Basic Electronics/Digital Logic (replaced C Programming ...

2011-05-14

161

In vitro investigation of biological and technical prosthetic heart valves in MRI: evaluation of possible deflection and heating of the implants; In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung moeglicher Anziehung und Erhitzung der Implantate  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: ...

2000-02-01

162

Successful transcatheter coil embolization of coronary artery to left ventricular fistula associated with absent pulmonary valve with tricuspid atresia in early infancy.  

Science.gov (United States)

Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713

2004-12-01

163

Special features of control and protection for large saturated steam turbines  

International Nuclear Information System (INIS)

For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).

164

Liquid level control system of fast reactor secondary cooling system  

International Nuclear Information System (INIS)

Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).

165

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

166

Grafoil applications on-plant  

International Nuclear Information System (INIS)

Presented in this report are the quantitative and qualitative aspects of the more than 5,800 applications of Grafoil on-plant. The subject all-graphite product was originally made by the Union Carbide Corporation. Its utilization in the forms of valve packing, gasketing and sealant tapes for leak repair and prevention on-plant since March 1970 is marked with typical zero-leak results. For all practical purposes, the successful results with Grafoil implementation indicate an unqualified control of leakage problems that began in 1967 with the V-11 and V-12 valves in the primary system of N Reactor. Meaningfully, the accruals of savings with existing and future applications shall continue to be incalculable in personnel exposure, maintenance, and capital. Inherent in the savings are the devised methodology and innovative developments coordinately employed in resolving the leak repair problems.

167

Fast leak in channel H9  

International Nuclear Information System (INIS)

The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.

168

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

169

Development and application of a diaphragm micro-pump with piezoelectric device  

British Library Electronic Table of Contents (United Kingdom)

In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...

2008-01-01

170

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).

1983-08-26

171

A vortex valve ejector combination for fluidic two diode pumps  

International Nuclear Information System (INIS)

Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).

172

Rack and pinion based fuelling machine of 540 MWe PHWR-from concept to refuelling  

International Nuclear Information System (INIS)

On-power refuelling is an integral feature of PHWR units. The most notable aspect of refuelling system of 540 MWe PHWR (TAPP-3 and 4) is that the FM Head is based on rack and pinion mechanism for B-ram and C-ram of Ram assembly. Latch ram used during plug operations, is assembled in between B-ram and C-ram and is moved by a ballscrew driven by oil hydraulic motors. This unique design has been employed for the first time in a PHWR unit. In comparison, B-ram is ballscrew driven and C-ram is moved by heavy water hydraulic force in FM Heads of 220 MWe PHWR units. Over the years, a number of design improvements have been carried out in the 220 MWe Fuelling Machines to meet the challenge of increasing demands of higher refuelling rates. However, in 540 MWe unit, the average refuelling rate for an equilibrium core is nearly twice that of 220 MWe units. Apart from other assemblies in FM Head, the performance of Ram assembly plays a key role in meeting this demand. The ...

2006-11-13

173

Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor  

International Nuclear Information System (INIS)

Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a tendency to degradation of the SG thermal efficiency was improved. On the other hand, it was clarified that ...

2009-10-01

174

Complexity of the microstructure evolution for optimization cBN growth in a four-step ion-assisted deposition process  

International Nuclear Information System (INIS)

The changes in microstructure of a specially prepared boron nitride (BN) film as a function of film depth were studied by high resolution transmission electron microscopy (HRTEM) and other materials analysis tools. These changes were then correlated to the changes in processing parameters during film growth. The analyzed film was fabricated by the four-step ion-assisted deposition procedure known to be effective in film-stress engineering for the formation and retention of a thick cubic BN (cBN) layer with a three-step buffer-layer deposition. In this deposition, the energy of the ions assisting cBN formation was increased stepwise from 200 to 280, and then to 360 eV [S.F. Wong, C. W. Ong, G.K.H. Pang, K.Z. Baba-Kishi, W. M. Lau, J. Vac. Sci. Technol. A 22 (2004) 676]. The nominal thickness of the cBN layer was 650 nm and that for each of the three buffer layers was about 160 nm. Both the HRTEM and electron diffraction results confirmed that the top cBN layer, with a thickness of 643 ...

2005-10-01

175

Wide cross-species aminoacyl-tRNA synthetase replacement in vivo: yeast cytoplasmic alanine enzyme replaced by human polymyositis serum antigen.  

UK PubMed Central (United Kingdom)

Because of variations in tRNA sequences in evolution, tRNA synthetases either do not acylate their cognate tRNAs from other organisms or execute misacylations which can be deleterious in vivo. We report...Full Text Available

1995-05-23

176

The tele-robotics system MT200-TAO replaces mechanical tele-manipulators in COGEMA/AREVA-La Hague hot cells  

International Nuclear Information System (INIS)

We present here for the first time the tele-robotics system for hot-cells MT200-TAO (TAO stands for Teleoperation Assistee par Ordinateur or Computer Assisted Tele-robotics), able to replace a conventional telescopic medium tele-manipulator (extension 4 m; capacity 20 kg). The system is currently under evaluation in COGEMA/AREVA- La Hague hot-cells. (authors)

2005-12-11

177

Selection and Implementation of a Replacement Cutting Tool Selection Application  

Energy Technology Data Exchange (ETDEWEB)

A new commercial cutting tool software package replaced an internally created legacy system. This report describes the issues that surfaced during the migration and installation of the commercial package and the solutions employed. The primary issues discussed are restructuring the data between two drastically different database schemas and the creation of individual component graphics.

2008-10-06

178

Effect of replacing dietary fish oil with soybean oil on production performance and fillet lipid and fatty acid composition of juvenile cobia Rachycentron canadum  

British Library Electronic Table of Contents (United Kingdom)

Abstract As a marine carnivore exhibiting exceptionally high growth rates, cobia are considered a species for which fish oil (FO) replacement may be difficult. However, partial, if not complete, FO replacement is necessary to ensure sustainability. We evaluated the effects of graded substitution of dietary FO with soybean oil (SO) in cobia culture. Feeds contained FO (100% FO), SO (0% FO) or blends of the two (67% FO, 33% FO) as the supplemental lipid source. Production performance was largely unaffected by partial replacement of FO with SO: feed intake and final weight were reduced only in the 0% FO dietary treatment. Fillet total lipid fatty acid (FA) composition differed among the dietary treatments, closely approximating dietary FA profile. As increasing amounts of FO were replaced, SO...

2011-01-01

179

The specific heat consumption and the loss mechanisms at the nozzle-group regulation of steam turbines; Zum spezifischen Waermeverbrauch und den Verlustmechanismen bei der Duesengruppenregelung von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue ...

1995-07-01

180

The safety concept of public gas supply in Germany  

Energy Technology Data Exchange (ETDEWEB)

The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)

1997-09-01

181

The potential of power fluidics for plant protection  

International Nuclear Information System (INIS)

The possibility of using Direct Flow Control (DFC) to avoid catastrophic accidents due to containment breaches in chemical plant is discussed. Recommendations are made for locating fluidic elements, and the effectiveness of simple DFC protection is analysed. More powerful methods of protection are outlined using spin diversion and the complementary properties of fluidic and conventional valves are exploited. (author).

182

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

183

Pressure surge analyses for conventional and nuclear power plants. Druckstossanalysen fuer konventionelle und nukleare Kraftwerke  

Energy Technology Data Exchange (ETDEWEB)

There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)

1993-09-01

184

Power fluidics and the environment  

International Nuclear Information System (INIS)

This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.

185

New safety device announced for nuclear power plants  

International Nuclear Information System (INIS)

An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.

186

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

187

Gas-diesel dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a gas-diesel dual fuel engine apparatus having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode.

1986-08-05

188

Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).

1987-01-01

189

Device for advancing the base of a stoping unit  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.

1980-12-13

190

Investigation of flora and fauna species of Lake Baikal by electron-probe microanalysis  

International Nuclear Information System (INIS)

Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. ...

191

Comparison of the UHF Follow-on and MILSTAR Satellite Communication Systems.  

Science.gov (United States)

The author compares the UHF Follow-on and MILSTAR satellite communication systems. The comparison uses an analytical hierarchy process. Although the two systems have been tasked with different missions, a comparison of cost, capability, and orbit is condu...

1991-01-01

192

Comparison of international source-term codes  

International Nuclear Information System (INIS)

Source-term codes to predict the release of radionuclides from nuclear waste packages have been developed and implemented worldwide. A survey and initial comparison of the attributes and capabilities of 13 international source-term codes was recently completed. This preliminary analysis focused on comparison of transport factors/processes and solution methods. This initial comparison is a necessary first step in a properly-conceived, systematic benchmarking of source-term codes. Advantages of such a comparison include assurance of the mathematical correctness of implemented models, comparison and quantification of variances introduced by different types of simplifications, and identification and quantification of the impact of near-field processes.

193

Radical Behaviorism and Buddhism: Complementarities and Conflicts  

UK PubMed Central (United Kingdom)

Comparisons have been made between Buddhism and the philosophy of science in general, but there have been only a few attempts to draw comparisons directly with the philosophy of radical behaviorism....Full Text Available

2008-01-01

194

IDSS: deformation invariant signatures for molecular shape comparison  

UK PubMed Central (United Kingdom)

BackgroundMany molecules of interest are flexible and undergo significant shape deformation as part of their function, but most existing methods of molecular shape comparison (MSC)...Full Text Available

195

COMPARISONS OF ... - NASA Technical Report Server (NTRS)  

Science.gov (United States)

W. Wayne Scott and R. G. Alsmiller, Jr. RADIATION SHIELDING ..... W. Wayne Scott and R. G. Alsmiller, Jr., "Comparisons of Results Ob- tained with Several ...

196

A comparison of benthic biodiversity in the North Sea, English ...  

Science.gov (United States)

A comparison of benthic biodiversity in the North Sea, English Channel, and Celtic Seas. ICES J. Mar. Sci./J. Cons. int. Explor. Mer 56: 228-246. ...

197

A Comparison of Some Demand Subject Searches: Machine vs. Human  

UK PubMed Central (United Kingdom)

A comparison of the results of machine and human information retrieval using MEDLARS and the printed Index Medicus indicates that at present neither method is entirely satisfactory...Full Text Available

1967-10-01

198

The replacement reaction controlling the fractal assembly of copper nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

In this paper we describe a fractal assembly of copper nanoparticles on different substrates by controlling the chemical replacement reaction. Through calculation, we found that the 'fractal dimensions' of copper dendrites synthesized by us were about 1.832, which agreed well with the 'fractal dimensions' of natural fern leaves (fractal dimension, 1.826), suggesting that the fern fractal model was useful to describe the self-assembly of our copper nanoparticles during the chemical replacement reaction process. These results will be beneficial for the understanding of the role that highly nonequilibrium conditions play in the formation of fractal clusters as well as the self-assembly mystique of metallic nanoparticles in nonequilibrium conditions and also helpful in the future assembly of complicated nanoarchitectures of metallic nanoparticles for potential applications.

2008-04-02

199

Studies on scintigraphic findings after femoral head replacement  

Energy Technology Data Exchange (ETDEWEB)

Femoral head replacement was performed for femoral neck fracture or femoral head necrosis on 36 hips of 34 patients on whom Tc-99m MDP scintigraphy was done for analysis of radioisotope uptake around the prosthesis. In the cases with satisfactory clinical course after replacement surgery the uptake was high in the area between the prosthesis and the trochanter, in the area of the stem tip of the prosthesis and in the acetabular area. The high uptake decreased gradually and reached a normal level by 8 months after surgery. The cases with no decrease of high uptake by 8 months after surgery were considered to have had an eventful postoperative course associated with some complication such as infection, fracture, loosening etc. Tc-99m MDP scintigraphy was useful for early detection of complications and to evaluate progress of the operated patients. (author)

2001-03-01

200

Effect of an Active Abdominal Pulse Generator on Defibrillation Thresholds with a Dual-Coil, Transvenous ICD Lead System  

British Library Electronic Table of Contents (United Kingdom)

Effect of Abdominal Active Can on DFTs. Introduction: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. Methods and Results: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ...

2006-01-01

204

Interstellar PAH Analogs in the Laboratory: Comparison with Astronomical Data  

Science.gov (United States)

Polycyclic Aromatic Hydrocarbons (PAHs) are an important and ubiquitous component of carbon-bearing

2005-01-01

217

A Stress-Dependent Hysteresis Model for Ferroelectric ...  

Science.gov (United States)

... Attributes and limitations of the charac- terization framework are illustrated through comparison with experimental PLZT data. ...

2011-05-13

218

Update of acute kidney injury: intensive care nephrology  

UK PubMed Central (United Kingdom)

Albeit the considerable progress that has been made both in our understanding of the pathophysiology of acute renal failure (ARF) and in its treatment (continuous renal replacement therapies), the morbidity...Full Text Available

2011-01-01

219

Thermal stability and acid resistance of aluminosilicophosphate zeolites  

Energy Technology Data Exchange (ETDEWEB)

By isomorphous replacement of silicon by phosphorus the authors have synthesized crystalline aluminosilicophosphates with structures of the zeolites type A and faujasite. They determine the adsorption capacity of specimens treated at 575-1275/sup 0/K. They show that the thermal stability and acid resistance of aluminosilicophosphates depend on the quantity of phosphorus in their structure.

1987-04-01

220

The zebrafish heart regenerates after cryoinjury-induced myocardial infarction  

UK PubMed Central (United Kingdom)

BackgroundIn humans, myocardial infarction is characterized by irreversible loss of heart tissue, which becomes replaced with a fibrous scar. By contrast, teleost fish and urodele...Full Text Available

221

THE EFFECTS OF RESPONSE EFFORT ON SAFE PERFORMANCE BY THERAPISTS AT AN AUTISM TREATMENT FACILITY  

UK PubMed Central (United Kingdom)

The effects of response effort on safe behaviors (i.e., glove wearing, hand sanitizing, and electrical outlet replacement) exhibited by therapists at an autism treatment center were examined. Participants...Full Text Available

2010-01-01

222

Sugar Efflux from Maize (Zea mays L.) Pedicel Tissue 1  

UK PubMed Central (United Kingdom)

Sugar release from the pedicel tissue of maize (Zea mays L.) kernels was studied by removing the distal portion of the kernel and the lower endosperm, followed by replacement of the...Full Text Available

1985-03-01

223

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

224

Research influence on antimalarial drug policy change in Tanzania: case study of replacing chloroquine with sulfadoxine-pyrimethamine as the first-line drug  

UK PubMed Central (United Kingdom)

IntroductionResearch is an essential tool in facing the challenges of scaling up interventions and improving access to services. As in many other countries, the translation of research...Full Text Available

226

Red mud as a catalyst for coal liquefaction  

Energy Technology Data Exchange (ETDEWEB)

In order to replace industrial cobalt and nickel and molybdenum catalysts, more economical catalysts, red muds, are used. Comparative data about the chemical, structural and thermal properties of different samples of red muds, which are important for catalytic hydrogenation, are cited. The different conditions for hydrogenation of coals in a reactor are examined.

1983-01-01

227

Rates of glucose utilization and glucogenesis in rats in the basal state induced by halothane anaesthesia.  

UK PubMed Central (United Kingdom)

1. Rates and rate coefficients of glucose utilization and replacement were determined with [5-3H]- and [U-14C]-glucose in rats starved for 24h, either conscious or under halothane anaesthesia, in a...Full Text Available

1977-03-15

228

Rare Homologous Gene Targeting in Histoplasma capsulatum: Disruption of the URA5Hc Gene by Allelic Replacement  

UK PubMed Central (United Kingdom)

URA5 genes encode orotidine-5′-monophosphate pyrophosphorylase (OMPpase), an enzyme involved in pyrimidine biosynthesis. We cloned the Histoplasma capsulatum URA5...Full Text Available

1998-10-01

229

Raised plasma glutathione S-transferase values in hyperthyroidism and in hypothyroid patients receiving thyroxine replacement: evidence for hepatic damage.  

UK PubMed Central (United Kingdom)

Using plasma glutathione S-transferase measurements hepatocellular integrity was assessed in groups of hyperthyroid and hypothyroid patients before and after treatment. Ten of 14 hyperthyroid patients...Full Text Available

1985-08-17

230

Lubricants respectful to environment  

Energy Technology Data Exchange (ETDEWEB)

The future lubricants could be vegetable oils in order to replace the petroleum products. Vegetable oils are biodegradable and inoffensive for environment and for people. The main uses of vegetable oils are indicated. (O.L.). 3 refs., 3 tabs.

1995-09-01

231

Left Main Coronary Stenosis as a Consequence of Bentall Operation: Percutaneous Treatment  

UK PubMed Central (United Kingdom)

A 65-year-old man suffering from ascending aorta aneurysm and atherosclerotic three vessel disease without left main involvement underwent aortic root replacement with coronary ostia reimplantation...Full Text Available

2009-01-01

232

Glucose turnover in the post-absorptive rat and the effects of halothane anaesthesia.  

UK PubMed Central (United Kingdom)

1. Rates and rate coefficients of glucose utilization and replacement in post-absorptive rats, either conscious or under halothane anaesthesia, were determined in a thermoneutral environment by using...Full Text Available

1977-03-15

233

Genotype-specific responses in Atlantic salmon (Salmo salar) subject to dietary fish oil replacement by vegetable oil: a liver transcriptomic analysis  

UK PubMed Central (United Kingdom)

BackgroundExpansion of aquaculture is seriously limited by reductions in fish oil (FO) supply for aquafeeds. Terrestrial alternatives such as vegetable oils (VO) have been investigated...Full Text Available

234

From high enriched to low enriched uranium fuel in research reactors  

International Nuclear Information System (INIS)

Since the 1970's, global efforts have been going on to replace the high-enriched (>90% "2"3"5U), low-density UAlx research reactor fuel with high-density, low enriched (<20% "2"3"5U) replacements. This search is driven by the attempt to reduce the civil use of high-enriched material because of proliferation risks and terrorist threats. American initiatives, such as the Global Threat Reduction Initiative (GTRI) and the Reduced Enrichment for Research and Test Reactors (RERTR) program have triggered the development of reliable low-enriched fuel types for these reactors, which can replace the high enriched ones without loss of performance. Most success has presently been obtained with U_3Si_2 dispersion fuel, which is currently used in many research reactors in the world. However, efforts to search for a replacement with even higher density, which will also allow the conversion of some high flux ...

235

Exploring the impact of a decision support intervention on vascular access decisions in chronic hemodialysis patients: study protocol  

UK PubMed Central (United Kingdom)

BackgroundIn patients with Stage 5 Chronic Kidney Disease who require renal replacement therapy a major decision concerns modality choice. However, many patients defer the decision...Full Text Available

236

Experimental autoimmune encephalomyelitis mobilizes neural progenitors from the subventricular zone to undergo oligodendrogenesis in adult mice  

UK PubMed Central (United Kingdom)

The destiny of the mitotically active cells of the subventricular zone (SVZ) in adult rodents is to migrate to the olfactory bulb, where they contribute to the replacement of granular and periglomerular...Full Text Available

2002-10-01

237

Examining the Phonological Neighborhood Density Effect Using Near Infrared Spectroscopy  

UK PubMed Central (United Kingdom)

Phonological density refers to the number of words that can be generated by replacing a phoneme in a target word with another phoneme in the same position. Although the precise nature of the...Full Text Available

2011-09-01

238

Efficacy of a meal replacement diet plan compared to a food-based diet plan after a period of weight loss and weight maintenance: a randomized controlled trial  

UK PubMed Central (United Kingdom)

BackgroundObesity has reached epidemic proportions in the United States. It is implicated in the development of a variety of chronic disease states and is associated with increased...Full Text Available

239

Effects of the direct thrombin inhibitor dabigatran on ex vivo coagulation time in orthopaedic surgery patients: a population model analysis  

UK PubMed Central (United Kingdom)

AimsTo describe the pharmacokinetic–pharmacodynamic (PK–PD) characteristics of the direct thrombin inhibitor dabigatran in hip replacement patients by assessing coagulation...Full Text Available

2006-11-01

240

Effects of a growth hormone-releasing hormone antagonist on telomerase activity, oxidative stress, longevity, and aging in mice  

UK PubMed Central (United Kingdom)

Both deficiency and excess of growth hormone (GH) are associated with increased mortality and morbidity. GH replacement in otherwise healthy subjects leads to complications, whereas individuals with...Full Text Available

2010-12-21

241

Effect of hypophysectomy on liver nuclear ribonucleic acid synthesis in aging rats.  

UK PubMed Central (United Kingdom)

Changes in RNA synthesis in liver nuclei were observed at different ages and after hypophysectomy and hormone replacement in female Sprague-Dawley rats. As determined by the incorporation of [3H]UMP...Full Text Available

1979-12-15

242

Downregulation of Serum Gonadotropins is as Effective as Estrogen Replacement at Improving Menopause-Associated Cognitive Deficits  

UK PubMed Central (United Kingdom)

While estrogen (E2) is thought to play an important role in age-related cognitive decline, neuronal plasticity, as well as the pathogenesis of Alzheimer disease (AD), the mechanisms by which...Full Text Available

2010-02-01

243

Dosing Recommendations for Continuous Venovenous Hemodiafiltration with AN69 Filter Membranes and Prismaflex Dialyzers  

UK PubMed Central (United Kingdom)

Background:Continuous renal replacement therapy is used to manage fluid and solute imbalances in critically ill patients but may affect the clearance of concurrently administered...Full Text Available

2009-11-01

244

Replace the Carburetor Diaphragm. Pulsa-Jet Style with Automatic Choke. Fuel System. Student Manual 2. Small Engine Repair Series. First Edition.  

Science.gov (United States)

This student manual, part of a small-engine repair series on servicing fuel systems, is designed for use by special needs students in Texas. The manual explains in pictures and short sentences, written on a low reading level, the job of replacing carburetor diaphragms. Along with the steps of this repair job, specific safety and caution information is frequently noted. To reinforce consistency in material presented to the slow learners, the pictures and written words correspond exactly with the pictures and wording on a corresponding audiovisual presentation. A progress chart for rating the students is included in the manual. (KC)

1981-12-01

245

Optimization of inspection and replacement period by using Bayesian statistics  

International Nuclear Information System (INIS)

This study describes the formulations to optimize the time interval of inspections and/or replacements of equipment/parts taking into account the probability density functions (PDF) for failure rates and parameters of failure distribution functions (FDF) and evaluates the optimized results of these time intervals using our formulations by comparing with those using only representative values of failure rates and the parameters of FDF instead of using these PDFs. The PDFs are obtained with Bayesian method and the representative values are obtained with likelihood estimation method. However, any significant difference is not observed between both optimized results within our preliminary calculations. (author)

2006-07-01

246

Fording Coal reduces preparation plant downtime with wear resistant lining  

Energy Technology Data Exchange (ETDEWEB)

Prior to 1986, the abrasive coking coal processed in the coal preparation plant at the Fording River operation at Elkford, British Columbia, was destroying the mild steel straight pipe and elbows at such a rate that they were having to be replaced annually and every 6-8 months respectively. To solve the problem, Fording River began to replace existing pipe and elbows with fused-cast, basalt-lined abrasion-resistant pipe, elbows and fittings manufactured by Abresist Corp. of Urbana, Indiana. The Abresist straight pipe has lasted 7 seven years and the Abresist elbows 5 years and both are still in use. 2 photos.

1994-04-01

247

The new BMW 4-cylinder engine in the 318i; Der neue BMW Vierzylindermotor im 318i  

Energy Technology Data Exchange (ETDEWEB)

The BMW four-cylinder two-valve engine was first launched in September 1987 as a 1.8 l engine and was described in detail in [1]. After initial optimisation for model year 94, four years later the engine has undergone a complete technical revision. From model year 98, the four-cylinder two-valve engine with appropriate exhaust emission technology will satisfy the EU3 class for exhaust emissions. (orig.) [Deutsch] Der BMW Vierzylinder-Zweiventilmotor wurde im September 1987 als 1,8-l-Motor erstmals vorgestellt und in [1] ausfuehrlich beschrieben. Nach einer ersten Optimierungsueberarbeitung zum Modelljahr 1994 wurde nun eine grundlegende technische Ueberarbeitung vorgenommen. Der Vierzylindermotor mit Zweiventiltechnik erfuellt als Antriebsaggregat in Verbindung mit einer entsprechenden Abgastechnik bereits ab Modelljahr 1998 die EU 3-Stufe fuer Abgasemissionen. (orig.)

1998-05-01

248

The influence of the layout-admission pressure loss on the control-statical properties of steam turbines; Der Einfluss des Auslegungs-Einstroemdruckverlustes auf die regelstatischen Eigenschaften von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The complete determination of stroke/throughput curves at steam turbines for arbitrary valve positions usually only follows after the fundamental layout of the control valves, of the possible nozzle segments and of the turbine blading. A general fundamental equation and some design norms based on it are presented which may serve already before a fluidic layout of the turbine in detail as an optimizing predetermination of the properties concerning pressure loss and control statics of the metering components in the admission area. (orig.) [Deutsch] Die vollstaendige Bestimmung der Hub-/Durchsatzkurven an Dampfturbinen fuer beliebige Ventilstellungen erfolgt ueblicherweise erst nach der Grundauslegung der Stellventile, etwaiger Duesensegmente und der Turbinenbeschaufelung. Es werden eine allgemeine Grundgleichung und einige auf ihr aufbauende Entwurfsregeln angegeben, die zu einer optimierenden Vorabbestimmung der druckverlustbezogenen ...

1997-06-01

249

Some medical applications of thermomechanically treated titanium nickelide  

Energy Technology Data Exchange (ETDEWEB)

An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first ...

2001-11-01

250

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

Energy Technology Data Exchange (ETDEWEB)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

251

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

International Nuclear Information System (INIS)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

252

Radioisotopic techniques for noninvasive detection of platelet deposition in bovine-tissue mitral-valve prostheses and in vitro quantification of visceral microembolism in dogs  

International Nuclear Information System (INIS)

Platelet deposition on bovine pericardial-tissue mitral-valve prostheses in 11 dogs was observed noninvasively by use of "1"1"1In-labeled platelets and quantified after sacrifice at one (n . 3), 14 (n . 3), and 30 (n . 5) days postimplantation (300-400 microCi of labeled platelets having been injected 24 hours previously). Thrombosis on the sewing ring and pericardial leaflets at one and 14 days and on the leaflets at 30 days was delineated in scintiphotos. In vitro quantification (% injected dose) indicated that the leaflets, sewing ring, and perivalvular tissue retained 0.904% of labeled platelets at one day postimplantation, 0.198% at 14 days, and 0.040% at 30 days. Platelet half-life was reduced to 38 hours at 21 days postimplantation but returned toward the normal (50 hours) with fibrous ingrowth in the sewing ring. Microembolism in lung and kidney, as measured by tissue/blood radioactivity ratio, also was decreased significantly at 30 days. "1"1"1In-labeled ...

253

Modeling the internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A flexible and computationally economical model of the internal combustion engine was developed for use on large digital computer systems. It is based on a system of ordinary differential equations for cylinder-averaged properties. The computer program is capable of multicycle calculations, with some parameters varying from cycle to cycle, and has restart capabilities. It can accommodate a broad spectrum of reactants, permits changes in physical properties, and offers a wide selection of alternative modeling functions without any reprogramming. It readily adapts to the amount of information available in a particular case because the model is in fact a hierarchy of five models. The models range from a simple model requiring only thermodynamic properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. Among its many features the model includes heat transfer, valve timing, ...

1985-03-01

254

Fault detection and fault diagnosis system for engine; Engine no kosho yochi shindan system  

Energy Technology Data Exchange (ETDEWEB)

The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and degradation of engine parts, it can transfer ...

1996-03-29

255

Establishment of Database Program for In-service Test Management in Nuclear Power Plants  

International Nuclear Information System (INIS)

In-service Test (IST) of the nuclear power plant is very important to maintain the safety of the plants. The safety features of nuclear power plant are based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves. Because of the importance of the IST, most of nuclear power plants should designate the IST department and personnel. Because the nuclear power plants of Korea have several types and the designs and operations are different from each other, the methods and experiences are various for the management of the IST program. However, there are no medium to communicate with each other and exchange the tips and information about IST program and education and discussion would be required to apply a consistent code. The nature of the IST Standardization Management Data Base (SMDB) is to exchange opinions and documents about IST program and ...

2010-10-01

256

Development of an efficient, low-NOx domestic gas-range cooktop. Phase 3. Annual technical report, January 1986-December 1986  

Science.gov (United States)

The objective of the program is to develop a domestic cooktop with low-NOx emissions and high efficiency. During the first two phases of the program, three design concepts were developed, and two versions of developmental prototypes using the IR-Jet approach were fabricated and tested. The third phase was initiated to address the design issues of burner turndown and modulation and to conduct the field test of a prototype with one IR-Jet and three conventional burners. Two prototypes containing one IR-Jet and three conventional burners and utilizing blower speed control for air/gas modulation were fabricated. One unit employed a brushless dc motor and the other a 2-pole ac motor. The ac motor prototype was field tested. Field testing showed the need for a mechanical air/gas valve for modulation and for a 1500 Btu/hr simmer setting. A 4-inch-diameter stepped-tile configuration provided input rates from 1500 to 8000 Btu/hr. A manufacturer, Copreci of Spain, started ...

1987-06-01

257

Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon  

Energy Technology Data Exchange (ETDEWEB)

To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and ...

1991-10-15

258

Combustion system for dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

This patent describes in an dual gas-liquid fuel four cycle engine having cylinders and wherein each cylinder is operatively connected thereto and each cylinder has a piston, two inlet valves, two exhaust valves and a first liquid fuel injector. It comprises: at least one fuel torch cell operatively connected to at least one cylinder, the torch cell having a torch cell nozzle at one end thereof and the other end having appropriate means to connect the torch cell to a fuel supply, a second fuel injector mounted in the torch cell at a predetermined angle to an axis of the torch cell, the torch cell defining an auto-ignition chamber, the second fuel injector being in operative communication with the auto-ignition chamber by an injector nozzle passageway, the injector nozzle passageway entering the auto-ignition chamber at a predetermined angle relative to the axis, and a torch nozzle passage connecting the auto-ignition chamber with the cylinder ...

1990-10-30

259

Synthesis, characterization and optical properties of a high NIR reflecting yellow inorganic pigment: Mo"6"+ doped Y_2Ce_2O_7 as a cool colorant  

International Nuclear Information System (INIS)

Full text: Pigments possessing the ability to confer high solar reflectance have received considerable attention in recent years. The inorganic class of NIR reflective pigments are mainly metal oxides and are primarily employed in two applications: (i) visual camouflage and (ii) reducing heat build up. More than half of the solar radiation consists of near-infrared radiation (52%), the remaining being 43% visible light and 5% ultraviolet radiation. Over heating due to solar radiation negatively affects comfort in the built environment and contributes substantially to electrical consumption for air conditioning and release of green house gases. A pigment which has strong reflections in the NIR region (780-2500 nm) can be referred to as a 'cool' pigment. However, most of the NIR reflective inorganic pigments particularly yellow (eg. cadmium yellow, lead chromate, chrome titanate yellow etc.) contain toxic metals and hence their consumption is being limited. Replacing ...

2010-11-24

260

Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for low-level and mixed low-level wastes has been restricted to lined trenches and the Navy reactor-compartment ...

2006-03-30

261

The Bevatron liquid nitrogen circulation system  

Science.gov (United States)

A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.

1987-03-01

262

Testing of the 1-MWth bench-model cavity-receiver steam generator  

Science.gov (United States)

A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)

263

Seconds capacity reserve and heat consumption with different operating procedures of steam turbines. Sekundenleistungsreserve und Waermeverbrauch bei verschiedenen Betriebsarten von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).

1989-09-01

264

Reducing the breakdowns and energy consumption in pressure regulating stations by rationalizing the heating of gas  

Energy Technology Data Exchange (ETDEWEB)

Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.

1982-04-01

265

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

266

Method and apparatus for operation of a dual fuel compression ignition combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A dual fuel engine control system for controlling the power output of a dual fuel compression ignition engine. The engine includes mixing means for combining an oxidizer and a primary fuel at a substantially constant ratio of oxidizer to primary fuel. The power output of the engine is controlled through the use of a throttle valve controlling the quantity of combustible mixture delivered to the combustion chamber. The fuel control system minimizes the quantity of ignition fuel required by controlling the quantity of combustible mixture rather than the fuel of air ratio. (author) figs.

1994-03-03

267

Isolated laevocardia and corrected transposition of the great vessels with total situs inversus  

International Nuclear Information System (INIS)

Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).

268

Improvement of assessment methodology for fluid flow characteristics of passive flow control device  

International Nuclear Information System (INIS)

The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.

2002-10-01

269

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1989-01-01

270

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1988-01-01

271

Error evaluation of the linearized equation of servo valve in hydraulic control systems  

International Nuclear Information System (INIS)

In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.

2001-11-01

272

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

273

Computer aided monitoring of pump efficiency by using ART2 neural networks; ART2 nyurarunettowaku niyoru ponpuseino no rekka shindan shien  

Energy Technology Data Exchange (ETDEWEB)

As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)

2000-05-10

274

Autogenous electrolyte, non-pyrolytically produced solid capacitor structure  

Energy Technology Data Exchange (ETDEWEB)

A solid electrolytic capacitor having a solid electrolyte comprising manganese dioxide dispersed in an aromatic polyamide capable of further cure to form polyimide linkages, the solid electrolyte being disposed between a first electrode made of valve metal covered by an anodic oxide film and a second electrode opposite the first electrode. The electrolyte autogenously produces water, oxygen, and hydroxyl groups which act as healing substances and is not itself produced pyrolytically. Reduction of the manganese dioxide and the water molecules released by formation of imide linkages result in substantially improved self-healing of anodic dielectric layer defects.

1998-01-01

275

W-12 valve pit decontamination demonstration  

Energy Technology Data Exchange (ETDEWEB)

Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste connection. Remote ...

1995-12-01

276

The direct comparison of health and ulcerated stomach tissue: A multiple probe microdialysis sampling approach  

UK PubMed Central (United Kingdom)

The ability to directly compare gastric ulcerated and healthy tissue would aid in the understanding of the physiological differences between these tissue types. Presently, these comparisons...Full Text Available

2008-09-10

277

Comparison of Soil Surface Temperature Measurements by Means of Standard Soil Mercury Thermometers and a Barnes Prt-5 Infrared Thermometer.  

Science.gov (United States)

A short account is given of the difficulties encountered in temperature measurement of boundary layers and a comparison of two types of thermometers, an infrared radiometer and mercury in glass thermometer. (Author)

1972-01-01

283

NOTICE THIS DOCUMENT HAS BEEN REPRODUCED FROM - NASA Technical ...  

Science.gov (United States)

The series hybrid vehicles were found to be relatively expensive in comparison to the parallel or parallel-flywheel hybrids. ...

284

Inter-comparison of some environmental radioactivity monitoring items for Guangdong Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear power plant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well

2003-01-01

285

Flue Gas Desulfurization and Low Btu Gasification - A ...  

Science.gov (United States)

... Accession Number : ADD419503. Title : Flue Gas Desulfurization and Low Btu Gasification - A Comparison Appendix G. ...

1975-05-01

291

A Comparison of the Technical Communications Practices of ...  

Science.gov (United States)

... Scientists. NASA/DoD Aerospace Knowledge Diffusion Research Project. Descriptive Note : Technical memo. rept. no. 29,. ...

1994-12-01

293

Comparison of SAND-II and FERRET  

Science.gov (United States)

A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters.

294

Replacement of fishmeal in cobia (Rachycentron canadum) diets using poultry by-product meal  

British Library Electronic Table of Contents (United Kingdom)

An 8-week feeding trial was conducted to evaluate the use of local poultry by-product meal (PBM) in replacement of imported fishmeal in the diets of cobia, Rachycentron canadum. Six isolipidic (12%) and isoproteic (45%) experimental diets were formulated using PBM to replace fishmeal at 20, 40, 60, 80 and 100% dietary protein. Eleven juvenile cobia (initial mean weight of 30.7???0.78?g) were randomly stocked in 300-L circular fibreglass tanks and hand-fed based on the total biomass of each tank, twice a day at 0900?h and 1500?h. The fish were group weighed at 2-week intervals to monitor their growth performance in order to adjust the feeding ratio. At the end of the feeding trial, weight gains (WGs) ranging from 221 to 322% were obtained. The specific growth rate (SGR), WG and protein effi...

2011-01-01

295

Optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 with an optimized cost perspective  

Energy Technology Data Exchange (ETDEWEB)

In this work, a model for determining the optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 is developed, which is to minimize economic loss caused by inadvertent trip and the system failure. This model uses cost benefit analysis method and the part for optimal inspection period considers the human error. The model is based on three factors as follows: (i) The cumulative failure distribution function of the safety system, (ii) The probability that the safety system does not operate due to failure of the system or human error when the safety system is needed at an emergency condition and (iii) The average probability that the reactor is tripped due to the failure of system components or human error. The model then is applied to evaluate the safety system in Wolsung Nuclear Power Plant Unit 1. The optimal replacement periods which are calculated with proposed model differ from those used in ...

1996-01-01

296

Evolution of the triangle zone in the Rocky Mountains Foothills near Coalspur, Central Alberta  

Energy Technology Data Exchange (ETDEWEB)

A triangle zone, which commonly occurs along the external margin of a foreland thrust and fold belt with a buried thrust front, is underlain by a subhorizontal, blind, foreland-verging thrust that ends against a foreland-dipping, hinterland-verging thrust. These contemporaneous thrusts, active towards the end of orogenesis, enclose an intercutaneous wedge that moved towards the foreland. During orogenesis, a triangle zone evolves through periodic replacement of faults bounding the active wedge. Replacements occur in cycles during each of which a lower fault tends to be replaced by one in a lower stratigraphic horizon, an upper fault by one farther away from the foreland. Each cycle ends with the lower fault moving to a younger horizon where it joins a new, more external upper fault. Near Coalspur, the triangle zone exposes the remnants of several wedges involving Upper Cretaceous and Palaeocene molasse. Most of these wedges ...

1987-08-01

297

Evaluation of red mud as pozzolanic material in replacement of cement for production of mortars; Avaliacao da lama vermelha como material pozolanico em substituicao ao cimento para producao de argamassas  

Energy Technology Data Exchange (ETDEWEB)

Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of ...

2010-07-01

298

Evaluation of red mud as pozzolanic material in replacement of cement for production of mortars  

International Nuclear Information System (INIS)

Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of ...

2010-11-21

299

Electron spin resonance probe for the solvation of ionomer membranes and other microscopically heterogeneous systems. Cu[sup 2+] in nafion, sephadex and silica gel  

Energy Technology Data Exchange (ETDEWEB)

Cu[sup 2+] is a sensitive electron spin resonance (ESR) probe for the penetration of various polar solvents in membranes made of Nafion and as an indicator for the replacement of one solvent by another. The ESR parameters (g and [sup 63]Cu hyperfine tensors) can be translated into a structure of the solvent around the cation. The replacement of a solvent in the membrane by another depends on the polarity of the two solvents. The solvent with the largest dielectric constant, N-methylformamide (NMF), can be replaced by water but not by methanol or acetonitrile (dielectric constants 182, 78.5, 32.7, and 37.5, respectively). Preferential solvation of the cation by water in three water/acetonitrile mixtures (9:1, 1:1, and 1:9 by volume) in contact with silica gel, Sephadex, and Nafion has been observed in various degrees. Nafion is most selective, followed by Sephadex and by silica gel. The selectivity appears to be related to ...

1992-01-01

300

Economic and reliability analysis in determining a programme for the technological renovation of gas networks  

International Nuclear Information System (INIS)

Gas Distribution Companies have long paid great attention to improving the quality of gas supply service to the consumer. This has involved them in an on-going attempt to successfully define and establish a clear computer assisted replacement programme which, when drawn up on a reliability basis, may also prove cost effective. The reasons which drive any gas line replacement programme are mainly related to the necessity: to improve the gas network asset so as to face a striking expected growth in gas demand; to refurbish old distribution systems with the purpose not only to increase the reliability and continuity of gas supply but also to reduce the rate of maintenance costs due to frequent repair works; to prevent the possibility of massive replacement works for a progressing ageing of the network. This paper will present the computer assisted procedure being implemented by Italgas. It ranks well defined network areas ...

1997-06-10

301

Cell volume regulation in hemoglobin CC and AA erythrocytes  

International Nuclear Information System (INIS)

Swelling hemoglobin CC erythrocytes stimulates a ouabain-insensitive K flux that restores original cell volume. Studies were performed with the K analog, "8"6Rb. This volume regulatory pathway was characterized for its anion dependence, sensitivity to loop diuretics, and requirement for Na. The swelling-induced K flux was eliminated if intracellular chloride was replaced by nitrate and both swelling-activated K influx and efflux were partially inhibited by 1 mM furosemide or bumetanide. K influx in swollen hemoglobin CC cells was not diminished when Na in the incubation medium was replaced with choline, indicating Na independence of the swelling-induced flux. Identical experiments with hemoglobin AA cells also demonstrated a swelling-induced increase in K flux, but the magnitude and duration of this increase were considerably less than that seen with hemoglobin CC cells. The increased K flux in hemoglobin AA cells was likewise sensitive to ...

302

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

303

Mobile offshore drilling rig newbuild and replacement cost functions  

British Library Electronic Table of Contents (United Kingdom)

Mobile offshore drilling rigs are used to drill, complete and workover wellbores in marine environments. The fleet that exists today consists of a wide variety of vessels built to various specifications over the past three decades, and because they operate in harsh, corrosive environments, they wear out structurally and require periodic maintenance. Rig designs have evolved with changes in operating requirements and new technology and rigs are frequently modified and upgraded, depending upon market conditions, operator preferences and other factors. The construction and replacement costs of offshore rigs are often used for management planning, financial valuation and insurance analysis, and because of the wide variety of designs, specifications and upgrades, cost estimates vary widely. In ...

2010-01-01

304

Micromachined electrostatic vertical actuator  

Energy Technology Data Exchange (ETDEWEB)

A micromachined vertical actuator utilizing a levitational force, such as in electrostatic comb drives, provides vertical actuation that is relatively linear in actuation for control, and can be readily combined with parallel plate capacitive position sensing for position control. The micromachined electrostatic vertical actuator provides accurate movement in the sub-micron to micron ranges which is desirable in the phase modulation instrument, such as optical phase shifting. For example, compact, inexpensive, and position controllable micromirrors utilizing an electrostatic vertical actuator can replace the large, expensive, and difficult-to-maintain piezoelectric actuators. A thirty pound piezoelectric actuator with corner cube reflectors, as utilized in a phase shifting diffraction interferometer can be replaced with a micromirror and a lens. For any very precise and small amplitudes of motion` micromachined electrostatic actuation may be ...

1999-10-19

305

Low enrichment fuel conversion for Iowa State University. Progress report, August 1, 1991--July 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the UTR-10 reactor at Iowa State University which went critical on low enriched uranium (LEU) fuel on August 14, 1991. However, subsequent to the criticality experiments the fuel plates started to discolor. In addition, roll pins used to lift the fuel assemblies were discovered to be cracked. It was determined that these problems were due to chemical agents in the primary coolant water. The roll pins were replaced by solid stainless steel pins. The primary coolant was replaced and the reactor is currently in operation. Surveillance specimens will be used to monitor any possible future discoloration. The high enriched fuel (HEU) is being prepared for eventual shipment to a high enriched fuel receiving facility.

1992-08-01

306

Low enrichment fuel conversion for Iowa State University  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the UTR-10 reactor at Iowa State University which went critical on low enriched uranium (LEU) fuel on August 14, 1991. However, subsequent to the criticality experiments the fuel plates started to discolor. In addition, roll pins used to lift the fuel assemblies were discovered to be cracked. It was determined that these problems were due to chemical agents in the primary coolant water. The roll pins were replaced by solid stainless steel pins. The primary coolant was replaced and the reactor is currently in operation. Surveillance specimens will be used to monitor any possible future discoloration. The high enriched fuel (HEU) is being prepared for eventual shipment to a high enriched fuel receiving facility.

1992-08-01

307

Life extension of boilers using weld overlay protection  

Energy Technology Data Exchange (ETDEWEB)

The presentation describes the status of modern weld overlay technology for refurbishment, upgrading and life extension of boilers. The approaches to life extension of boilers include field overlay application, shop-fabricated panels for replacement of the worn, corroded waterwall and shop-fabricated overlay tubing for replacement of individual tubes in superheaters, generating banks and other areas. The characteristics of weld overlay products are briefly described. Also discussed are successful applications of various corrosion-resistant overlays for life extension of boiler tubes in waste-to-energy boilers, coal-fired boilers and chemical recovery boilers. Types of corrosion and selection of weld overlay alloys in these systems are also discussed. (orig.) 14 refs.

1998-12-31

308

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

309

In situ ligand exchange of thiol-capped CuInS2/ZnS quantum dots at growth stage without affecting luminescent characteristics  

British Library Electronic Table of Contents (United Kingdom)

An aliphatic thiol ligand of CuInS2/ZnS core/shell quantum dots is replaced with a hydroxyl-terminated thiol ligand by utilizing `on-off state' of ligands during growth stage of the quantum dots. After the ligand-exchange, negligible differences were observed on both photoluminescence spectrum and luminescent quantum efficiency. The reason for the high retention of luminescent efficiency comes from no local agglomeration and no surface deterioration of QDs. It is also observed that 70% of initial ligands are exchanged by the replacing ligand, determined by FT-IR and 1H NMR. The proposed method provides the quantum dots with an excellent dispersibility in polar solvents, supported by identical luminescence decay characteristics of the QDs.

2011-01-01

310

Global Existence of Weak Solutions to a Nonlocal Cahn-Hilliard-Navier-Stokes System  

CERN Document Server

A well-known diffuse interface model consists of the Navier-Stokes equations nonlinearly coupled with a convective Cahn-Hilliard type equation. This system describes the evolution of an incompressible isothermal mixture of binary-fluids and it has been investigated by many authors. Here we consider a variant of this model where the standard Cahn-Hilliard equation is replaced by its nonlocal version. More precisely, the gradient term in the free energy functional is replaced by a spatial con- volution operator acting on the order parameter phi. Therefore the coupling with the Navier-Stokes equations is difficult to handle even in two spatial dimensions because of the lack of regularity of phi. We establish the global existence of a weak solution.

2011-01-01

311

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is considered the method ...

312

A method for producing a filtering material for organic substances  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for making a filtering material (FM) through applying bitumen or tar to a porous substance and subsequent roasting. Blast furnace slag, pumice and other inorganic substances are used as the porous substance. The method makes it possible to acquire an inexpensive filtering material with a developed surface (Pv), which replaces activated charcoal. Example. Blast furnace slag is heated to 200 to 300 degrees and with mixing is impregnated by 5 to 15 percent bitumen or tar. The impregnated slag is roasted at 800 to 1,000 degrees until full carbonization of the bitumen or tar, acquiring in this way a filtering material, which is characterized by a specific surface of 700 to 1,000 square centimeters per gram and suitable as a replacement for activated charcoal for removing organic components and heavy metals from gaseous and liquid phases. The cost of the filtering material is one eighth to one tenth of that of activated charcoal.

1981-06-27

313

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam ...

1999-05-01

314

Tickover speed controller for car engines  

Energy Technology Data Exchange (ETDEWEB)

In general, the tickover speed of a car engine is made sufficiently high, in order to permit an assumed maximum load to be taken from the engine at tickover. This setting of the tickover speed is usually done by stops in the fuel supply. Matching the actual load would lead to lower fuel consumption, without any danger of the engine stalling. The purpose of the invention is to provide a tickover speed controller, so that the tickover speed is adjusted by electronic control equipment, independently of the machine load. The fuel consumption on tickover is reduced and the emission of noxious substances is decreased. The electro-magnetic control of the throttle valve tickover setting is explained by extensive section drawings of the system. This process dispenses with the special tickover cams for a cold start.

1980-05-22

315

The influence of bowl offset on air motion in a direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The influence of bowl offset on motored mean flow and turbulence in a direct injection diesel engine has been examined with the aid of a multi-dimensional flow code. Results are presented for three piston geometries. The bowl geometry of each piston was the same, while the offset between the bowl and the cylinder axis was varied from 0.0 to 9.6% of the bore. The swirl ratio at intake valve closing was also varied from 2.60 to 4.27. It was found that the angular momentum of the air at TDC was decreased by less than 8% when the bowl was offset. Nevertheless, the mean (squish and swirl) flows were strongly affected by the offset. In addition, the distribution of turbulent kinetic energy (predicted by the /delta/-e model) was modified. Moderate increases (10% or less) in mass averaged turbulence intensity at TDC with offset were observed.

1988-01-01

316

The chance finding of an aneurysm of the right sinus of Valsalva in an 11-year-old child with a ventricular septal defect and a pericardial effusion  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...

2011-01-01

317

Surge-line thermal stratification: Displacements and fatigue damage computations  

Energy Technology Data Exchange (ETDEWEB)

Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. Alternative solutions for coping with ...

1989-01-01

318

Start safety apparatus for internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.

1986-09-09

319

Powertrain and apparatus using a continuously variable ratio transmission to improve fuel economy  

Energy Technology Data Exchange (ETDEWEB)

An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are optimized to produce exceptional fuel economy.

1981-07-28

320

New technology for purging the steam generators of nuclear power plants  

British Library Electronic Table of Contents (United Kingdom)

A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...

2011-01-01

321

Natural radioactive materials in oil and gas industry  

International Nuclear Information System (INIS)

Oil and gas production and processing operations sometimes cause naturally occurring radioactive materials (NORM) to accumulate at elevated concentrations in by-product waste streams. The sources of most of the radioactivity are isotopes of "2"3"8U and "2"3"2Th series, which are naturally present in the subsurface formations from which oil and gas are produced. NORM waste may cause problems in the operations of installations by plugging perforations, clogging tubular and valves then restricting flow. Therefore, plants or equipment have to be refurbished and decontaminated before reuse to avoid radioactive waste or surface contaminated object. There are two options for safe disposal of scale and sludge produced from NORM Descaling Facility : 1- Injection into an abandoned production well. 2- The construction of a near surface depository. These options are assumed to be environmental friendly disposal options. (author)

2010-03-01

322

Method of feeding a coolant into a reactor  

International Nuclear Information System (INIS)

Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).

323

Measuring air movement locally in the combustion chambers of a direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

Measurements of smoke and NO emissions from a direct-injection diesel engine have shown that they are indeed influenced by inlet port design, even though the swirl numbers for the ports may be identical. The swirl numbers of the three ports used (tangential port, helical port and helical port with masked valve) were measured on a steady-state test rig using a paddle-wheel anemometer and impulse swirl meter. Flow measurements were carried out under motoring conditions with a constant-temperature, hot-wire anemometer. Is was possible to find a correlation between flow data and exhaust data as far as the in-cylinder air motion over a certain time interval is concerned.

1983-02-01

324

Influence of performance characteristic of a gaseous fuel supply system on hydrocarbon emissions of a dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

The performance of the gaseous fuel supply and its influence on hydrocarbon (HC) emissions of dual-fuel engines have been investigated. A new design of manifold respirators with mixers is also presented in the paper. The design of the gaseous fuel supply system has a great influence on HC emissions in the dual-fuel engine at light load. The problem of scavenging is discussed and solved by using the manifold respirators in the dual-fuel engine. It performs the function of retarding the gaseous fuel entry timing from the moment of intake valve opening, and its delaying effects have been measured and tested. Experimental results show that the manifold respirator gives the best performance in reducing HC emissions compared with a common pipe mixer and a respirator with bo miser. In addition, the mixing effects are sensitive to the mixer configuration. (Author)

2000-11-01

325

Gene Regulation of Extracellular Matrix Remodeling in Human Bone Marrow Stem Cell-Seeded Tissue-Engineered Grafts  

British Library Electronic Table of Contents (United Kingdom)

Tissue-engineered heart valves are prone to early structural deterioration. We hypothesize that cell?scaffold interaction and mechanical deformation results in upregulation of genes related to osteogenic/chondrogenic differentiation and thus changes extracellular matrix (ECM) composition in human bone marrow mesenchymal stem cell (hBMSC)-derived tissue-engineered grafts. hBMSC were expanded and seeded onto poly-glycolic acid/poly-lactic acid scaffold for 14 days. Seeded tissue-engineered constructs (TEC) were subjected to cyclic flexure for 24?h, whereas control TEC was maintained in roller bottles for the same duration. hBMSC, TEC, and mechanically deformed TEC were subjected to gene-array and histological analysis. Expression levels of RNA and/or protein markers related to chondrogenesis...

2011-01-01

326

Fuel injection control for diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.

1987-11-10

327

Friction in ultra-thin conjunction of valve seals of pressurised metered dose inhalers  

British Library Electronic Table of Contents (United Kingdom)

In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...

2010-01-01

328

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel  

British Library Electronic Table of Contents (United Kingdom)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...

2010-01-01

329

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...

330

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

331

Detection of intracardiac calcification using Fuji computed radiography  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).

1986-01-01

332

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

333

Chitons (Mollusca, Polyplacophora) du Pleistocene tardif et de l'Holocene d'Uruguay : paleobiogeographie et reconstruction paleoenvironnementale aux latitudes moyennes de l'Atlantique du sud-ouest  

British Library Electronic Table of Contents (United Kingdom)

Here we present a revision of the fossil record of chitons (Mollusca, Polyplacophora) of Late Pleistocene and Holocene marine deposits of Uruguay and discuss their potential for palaeoenvironmental reconstruction. Chitons were recorded as isolated valves in bivalve- and gastropod-rich assemblages. They are represented by the species Chaetopleura angulata (Spengler), C. isabellei (d'Orbigny), C. asperrima (Gould) and Ischnochiton striolatus (Gray). The last two species are recorded for the first time as fossils not only in Uruguay but also in South America. Exclusively recorded for the Late Pleistocene is the warm water species I. striolatus, whose current southern range limit is located in Santa Catarina, Brazil. Higher temperatures than at present are inferred for the Uruguayan coast duri...

2011-01-01

334

Characterization and effect of using cotton methyl ester as fuel in a LHR diesel engine  

International Nuclear Information System (INIS)

In the present study, surfaces of cylinder head, piston, exhaust and inlet valve of a four-stroke, direct injection, single cylinder diesel engine were coated with molybdenum (Mo) by plasma spray method. Thus, thermal barrier characteristic was brought to these parts. Variances in performance and emission values of cotton methyl ester and 2D fuel mixtures were studied in the ceramic coated and uncoated engines under the same running conditions. Performance (6.0% for specific fuel consumption) and emission values (up to 18.0% for CO, 8.0% for smoke density) of the test fuel were improved in the coated engine compared with the uncoated engine. NO_x increase (4.5%) with the increased temperatures expected in the coated engine.

2011-01-01

335

Calculation model testing for the case of rcs hot collector rupture inside the horizontal steam generator of VVER-440 NPP  

Energy Technology Data Exchange (ETDEWEB)

The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).

1993-12-31

336

Calculation model testing for the case of rcs hot collector rupture inside the horizontal steam generator of VVER-440 NPP  

International Nuclear Information System (INIS)

The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).

1992-09-29

337

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.

1985-07-03

338

An historical view of the pineal gland and mental disorders  

British Library Electronic Table of Contents (United Kingdom)

Since Classical Antiquity numerous authors have linked the origin of some mental disorders to physical and functional changes in the pineal gland because of its attributed role in humans as the connection between the material and the spiritual world. The pineal organ was seen as a valve-like structure that regulated the flow of animal spirits through the ventricular system, a hypothesis that took on more vigour during the Middle Ages and the Renaissance. The framework for this theory was ''the three cells of the brain'', in which the pineal gland was even called the ''appendix of thought''. The pineal gland could also be associated with the boom, during this period, of certain legends about the ''stone of folly''. But the most relevant psychopathological role of this organ arrived with Des...

2011-01-01

340

XLPE cables move in on underground transmission  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in cross-linked polyethylene cables mean they can be used at higher voltages and are starting to replace some oil-filled cables. Their good thermal and electrical properties, easy installation and minimal maintenance have helped their growth. A group at Sumitomo Electric Industries Ltd., Japan is studying the performance of these cables. (author).

1986-02-01

341

The scintigraphy of the brain: development, methods and present consequence  

International Nuclear Information System (INIS)

Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).

342

Production of "2"0"3Pb by proton irradiation of Bi  

International Nuclear Information System (INIS)

Production of lead-203 by proton irradiation of bismuth metal has been investigated as a replacement method for commercially available lead-203. Targets of bismuth metal (0.1 cm thick) were irradiated for periods of 1-3 hours with 90 MeV protons. After processing of the target, the estimated yield of lead-2-3 was 30 millicuries/microamp.

1990-06-24

343

Procedure for economic evaluation of steam turbine drives versus electric drives  

Energy Technology Data Exchange (ETDEWEB)

This EPRI sponsored report describes factors that influence the selection of drives in process industry. These factors include economics, safety aspects, speed control and the plant steam balance. Since the economics play a key-role in the decision, this report provides a quick way of estimating the economics of replacing steam turbines with electric motors. The tools to carry out economic analyses have been provided in the form of graphs and nomographs for quick estimation.

1992-10-01

344

Power and ecological aspects of hydrogen and hydrogenous gas usage  

International Nuclear Information System (INIS)

General trends of developing hydrogen power engineering and technology in Ukraine are considered. Based on a general level of power consumption and real opportunities for hydrogen production, a conclusion is derived that there are possibilities in the near future to partially replace conventional hydrocarbon fuels by hydrogen. Besides, developed technologies for burning hydrogenous gases and hydrogen-fuel systems when applied to transport installations allow one to improve essentially their power and ecological characteristics. 5 refs.

345

Organ transplantation and replacement  

Energy Technology Data Exchange (ETDEWEB)

This book contains 49 chapters. Some of the titles are: Molecular, Genetic, and Clinical Aspects of the HLA System; The Normal Immune Response; Significance of the ABO Antigen System; The Role of Dialysis in the Management of End-Stage Renal Disease; Access for Dialysis; Patient Selection for Renal Transplantation; The Living Donor in Kidney Transplantation; and Kidney Preservation by Cold Storage.

1988-01-01

346

Optimizing semiconductor devices by self-organizing particle swarm  

CERN Document Server

A self-organizing particle swarm is presented. It works in dissipative state by employing the small inertia weight, according to experimental analysis on a simplified model, which with fast convergence. Then by recognizing and replacing inactive particles according to the process deviation information of device parameters, the fluctuation is introduced so as to driving the irreversible evolution process with better fitness. The testing on benchmark functions and an application example for device optimization with designed fitness function indicates it improves the performance effectively.

2005-01-01

347

On-line replacement of a particle accelerator control computer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the conversion from an existing production control computer, an SEL 840, to a DEC VAX 11/780. The plan is to add a layer of hardware to accomplish a smooth and gradual transition from the 840 to the VAX while leaving the underlying equipment unchanged. The architecture of the control system software is discussed for a large linear accelerator from the standpoint of its requirements and the particular design philosophy chosen.

1981-01-01

348

New uses for coal  

Energy Technology Data Exchange (ETDEWEB)

As oil supplies diminish, Britain will have to rely more and more on coal as one of the energy alternatives. To burn coal cleanly and efficiently coal will have to be converted into gas and liquid fuels to replace natural gas and oil. The research and development programme of the National Coal Board is directed towards meeting these new challenges. This paper outlines some of the Coal Board's current projects in the fields of industrial combustion, power generation, domestic combustion, coal gasification and coal liquefaction. 10 figs.

1981-01-01

349

Mechanism of denting corrosion  

International Nuclear Information System (INIS)

The rapid corrosion of carbon steels in high temperature, acid chloride solutions is shown to be rate limited by the anodic reaction, 3Fe + 4H_2O = Fe_3O_4 + 8H"+ + 8e"-, based on experiments which find that the corrosion rate in 0.1M NiCl_2 solution has an activation energy of 60 kJ/ mole and is unaffected by adding NaCl or by replacing NiCl_2 with PtCl_4. (author).

350

Kevlar and carbon composites compared  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of advanced composites are investigated. The fibers considered are Kevlar and carbon. The greatest advantage of composites over metals is emphasized, and lies in their permitting designers to obtain properties in exactly the locations desired. Kevlar replaced S-glass on the Trident 2 missile, saving 800 lbs. and adding 800 miles to its range. Military aircraft builders find that advanced carbon composites more often than not win out over Kevlar.

1985-02-01

351

Kaluza-Klein mixmaster universes  

Energy Technology Data Exchange (ETDEWEB)

We analyze the behavior of some Bianchi type-IX, mixmaster cosmological models possessing extra dimensions. We find that, unlike the three-dimensional case, they do not exhibit chaotic behavior on approach to their initial singularity. A finite sequence of stochastic mixmaster oscillations is, in general, replaced by monotonic contraction of the three-space scale factors on approach to a singularity whenever additional spatial dimensions exist with the metric form we consider.

1985-09-15

352

Kaluza-Klein mixmaster universes  

International Nuclear Information System (INIS)

We analyze the behavior of some Bianchi type-IX, mixmaster cosmological models possessing extra dimensions. We find that, unlike the three-dimensional case, they do not exhibit chaotic behavior on approach to their initial singularity. A finite sequence of stochastic mixmaster oscillations is, in general, replaced by monotonic contraction of the three-space scale factors on approach to a singularity whenever additional spatial dimensions exist with the metric form we consider.

353

Improving cost-effectiveness for the furnace in a full-scale refinery plant with reuse of waste tail gas fuel  

Energy Technology Data Exchange (ETDEWEB)

The waste tail gas fuel emitted from refinery plant in Taiwan e.g. catalytic reforming unit, catalytic cracking unit and residue desulfurization unit, was recovered and reused as a replacement fuel. In this study, it was slowly added to the fuel stream of a heater furnace to replace natural gas for powering a full-scale distillation process. The waste tail gas fuel contained on average 60 mol% of hydrogen. On-site experimental results show that both the flame length and orange-yellowish brightness decrease with increasing proportion of waste gas fuel in the original natural gas fuel. Moreover, the adiabatic flame temperature increases as the content of waste gas fuel is increased in the fuel mixture since waste gas fuel has a higher adiabatic flame temperature than that of natural gas. The complete replacement of natural gas by waste gas fuel for a heater furnace operating at 70% loading (i.e. 3.6 x 10{sup 7} kcal/h of ...

2010-02-15

354

Enzyme discovery in hybrid aspen for fibre engineering  

Environmental Research Database

DescriptionEnzymes are natural catalysts that are used increasingly to replace environmentally harmful chemicals and to achieve better catalytic selectivity during pulp and paper processing. The main objective of this project is to identify novel plant enzymes for deeper understanding of the process of fibre formation and for future improvement of the quality parameters of wood fibres. Specific modification of the fibre characteristics will facilitate their use as raw materials for the current pulp and pap [continued...

2005-01-31

355

Diffusion absorption heat pump. Diffusion-Absorptions-Waermepumpe  

Energy Technology Data Exchange (ETDEWEB)

The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.

1992-02-01

356

D-Glyceraldehyde-3-Phosphate Dehydrogenase: Three-Dimensional Structure and Evolutionary Significance  

UK PubMed Central (United Kingdom)

A 3.0-Å resolution electron density map of lobster glyceraldehyde-3-phosphate dehydrogenase (EC 1.2.1.12) was computed. The essentially single isomorphous replacement map was very substantially...Full Text Available

1973-11-01

357

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

358

Coatings with controlled porosity and chemical properties  

Energy Technology Data Exchange (ETDEWEB)

Coatings and sensors having both steric and chemical selectivity. Controlled porosity provides the steric selectivity, whereas chemically tailored film properties, using controlled composition or modification by coupling agents, chemical species replacement, or chemical species within pores, provide the chemical selectivity. Single or multiple layers may be provided.

1996-01-01

359

Characterization of wood polymer composites (WPC) as an engineering material  

International Nuclear Information System (INIS)

Radiation processed wood-polymer composites (WPC) can replace conventional wood in many industrial applications. However, for proper utilization of the composites, adequate testing and evaluation programmes are essential. The paper briefly describes the development of WPC at the Bhabha Atomic Research Centre, Bombay, and the evaluation of WPC for various applications in greater details. The various mechanical properties and their significance in overall performance of WPC are also discussed. (author).

1980-08-01

360

Biochemical changes in human cervical connective tissue after local application of prostaglandin E2  

DEFF Research Database (Denmark)

Intracervical application of prostaglandin E2 in the late first trimester induces (1) softening of the cervix tissue; (2) increase in sulfated glycosaminoglycans (18 +/- 12%, mean +/- SEM); (3) no change in hyaluronic acid and water; (4) decrease in pepsin-extractable collagen, and (5) apparent decrease in collagenase. A high activity of collagenase in combination with a replacement of collagen with sulfated glycosaminoglycans may be of importance for the ripening process.

1983-01-01

361

Bio gasification of industrial bio waste and sewage sludge-management of biogas quality  

International Nuclear Information System (INIS)

Bio gasification, i. e. anaerobic digestion, is a well known sustainable option for the management of organic solid wastes and sludges. the produced biogas is a valuable bio fuel to replace fossil fuels in different technical applications (like heating, electricity, transport fuel generation) which in turn determine its quality requirements. (Author)

362

AUTOMATIC LIQUID NITROGEN PUMPING SYSTEM FOR PARTICLE ACCELERATORS  

Science.gov (United States)

A description is given of an automatic liquid nitrogen pumping system. Pamping of liquid nitrogen iato cooling traps up to a predetermined level is achieved by an automatically controlled compressed air system. An impontant feature of the equipment is the ability to switch automatically from an empty liquid nitrogen reservoir to a full one. This allows for a much more flexible operation than in conventional systems where the reservoir has to be replaced manually when empty. (auth)

1963-04-16

363

ALARA Center of Technology -- resource guide  

Energy Technology Data Exchange (ETDEWEB)

The purpose is to provide a source of information that can be used to assist personnel in the planning, training, and execution of radiological work using the principles of ALARA. This document is not intended to replace HNF or WHC Control Manual requirements. The ALARA Tools-List provides detailed information on the use and procurement of engineered controls, mockup training guidelines, and good radiological work practices that have been proven to be ALARA.

1998-02-05

364

The new 2.2 l ECOTEC aluminium engine by Opel; Der neue 2,2-l-ECOTEC-Aluminium-Motor von Opel  

Energy Technology Data Exchange (ETDEWEB)

The ECOTEC combustion system and the architecture of the new Opel 2.2 l aluminum engine have been configured to achieve low noise and exhaust emissions. This power unit, employed in Germany for the first time in the Astra Coupe, already complies with the Euro IV emissions standard. It features minimum maintenance requirements and a long operating life. The DOHC spark-ignition engine with four valves per cylinder has two chain-driven camshafts, valve gear with roller cam followers and hydraulic lash adjusters. Two chain driven balancer shafts have been integrated into the engine block. The cylinder head and block, lower crankcase, oil pan, and cylinder head cover are all made of aluminum. A modular concept makes it possible to adapt the engine effectively to different vehicle concepts and markets. (orig.) [German] Das ECOTEC-Verbrennungssystem und die Motorarchitektur des neuen 2,2-l-Aluminium-Triebwerks von Opel sind auf niedrige Geraeusch- und ...

2000-09-01

365

Simulations of the design basis accident at conditions of power increase and the o transient of MSIV at overpressure conditions of the Laguna Verde Power Station; Simulaciones del accidente base de diseno a condiciones de aumento de potencia y del transitorio de cierre de MSIV a condiciones de sobrepresion de la Central Laguna Verde  

Energy Technology Data Exchange (ETDEWEB)

This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is concluded that the integrity of the containment is not challenged during a loss of coolant accident at ...

2001-07-01

366

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat pipe, in which the return of the condensate to the evaporator section is achieved by the movement of the heat pipe. The ...

2004-07-01

367

HT technology -- All-metal sealing answers safety and environmental concerns  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the ...

1995-12-31

368

Gas-diesel dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

A gas-diesel dual fuel engine apparatus is described having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including a gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine through the control of fuel supplied to the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode. The improvement of the governing and controlling device consists of: (a) at least one electronic governor means adapted to compare a speed signal representing the actual operating speed of the diesel engine with a set speed signal representing the set speed thereof; (b) a pair of electric actuator means having respective power amplifier circuits and mechanically connected to the diesel fuel injection pump and the gaseous fuel regulating valve, respectively, for the actuation thereof; (c) mode ...

1986-03-18

369

Electron-beam welding of valve bodies; Elektronenstrahlschweissen von Armaturengehaeusen  

Energy Technology Data Exchange (ETDEWEB)

In early March, 2000 a modern electron-beam welding facility for both series and one-off production of valves bodies (500 kg, up to 50 mm wall thickness) was commissioned at Josch Strahlschweisstechnik. Welding is performed under a fine vacuum. This permits not only the welding of components subject to acceptance inspection (HP0 approval), but also of special materials such as titanium, molybdenum, tungsten, Hastelloy and copper, and also their pairings. Products are developed and readied for production using modern 3D CAD software. A modern nine-axis control system makes it possible to produce sockets in pipe-on-pipe joints. (orig.) [German] Anfang Maerz 2000 wurde eine moderne Elektronenstrahlschweissanlage fuer die Herstellung von Armaturengehaeusen in Grossserien oder auch fuer Einzelfertigung (500 kg, bis 50 mm Wanddicke) bei der Josch Strahlschweisstechnik in Betrieb genommen. Die Schweissungen erfolgen im Feinvakuum. Somit koennen neben dem Schweissen ...

2000-03-01

370

A Human Reliability Analysis of Pre-Accident Human Errors in the Low Power and Shutdown PSA of the KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified pre-accident human ...

2003-04-20

371

Performance evaluation and enhancement of SuperLU{_}DIST 2.0  

Energy Technology Data Exchange (ETDEWEB)

We present the runtime comparison of the two versions of Super LU{_}DIST, using up to 128 processors of the IBM SP at NERSC. One version provides the global input interface, and another provides the distributed input interface. The comparison includes the total runtime of the solver with both 32-bit and 64-bit addressing modes, the time breakdown for different phases of the solver. We also present an in-depth comparison off our sparse matrix-vector multiplication methods in the context of iterative refinement. Finally, we describe our Fortran 90 interface that enhances the usability of the software.

2003-08-28

372

Performance Comparisons of PSO based Clustering  

CERN Document Server

In this paper we have investigated the performance of PSO Particle Swarm Optimization based clustering on few real world data sets and one artificial data set. The performances are measured by two metric namely quantization error and inter-cluster distance. The K means clustering algorithm is first implemented for all data sets, the results of which form the basis of comparison of PSO based approaches. We have explored different variants of PSO such as gbest, lbest ring, lbest vonneumann and Hybrid PSO for comparison purposes. The results reveal that PSO based clustering algorithms perform better compared to K means in all data sets.

2010-01-01

373

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy X-rays  

International Nuclear Information System (INIS)

A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)

2010-12-01

374

Comparison of the green- and infrared-stimulated luminescence of feldspar  

Energy Technology Data Exchange (ETDEWEB)

The differences are highlighted of various aspects of behaviour of the luminescence signal from feldspar when stimulated by green light and when stimulated by infrared radiation. In respect of bleaching, a comparison is made of the influence of white light (daylight) on the two stimulated luminescence signals, as well as a comparison of the influence of infrared exposure on the green-stimulated signal with the influence of green exposure on the infrared-stimulated signal. The influence of preheating on the two stimulated signals is also compared. Light-emitting diode systems were used for both green and infrared stimulation. The observations are considered in relation to the mechanism relevant to green- and infrared-stimulated luminescence from feldspar. (author).

1994-04-01

375

Comparison of the green- and infrared-stimulated luminescence of feldspar  

International Nuclear Information System (INIS)

The differences are highlighted of various aspects of behaviour of the luminescence signal from feldspar when stimulated by green light and when stimulated by infrared radiation. In respect of bleaching, a comparison is made of the influence of white light (daylight) on the two stimulated luminescence signals, as well as a comparison of the influence of infrared exposure on the green-stimulated signal with the influence of green exposure on the infrared-stimulated signal. The influence of preheating on the two stimulated signals is also compared. Light-emitting diode systems were used for both green and infrared stimulation. The observations are considered in relation to the mechanism relevant to green- and infrared-stimulated luminescence from feldspar. (author).

1993-07-01

376

Comparison of Atmospheric Dispersion Models Between PHWR and PWR  

International Nuclear Information System (INIS)

The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences

2010-10-01

377

W-7405 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

W. Wayne Scott and R. G. Alsmiller, Jr. ABSTRACT. Comparisons of the results obtained for a hypothetical problem with four different proton penetration ...

380

Sample manuscript showing specifications and style - NASA ...  

Science.gov (United States)

Figure 7: Horak Cost Estimating Relationship with Statistical Details. For this comparison, we ignore the Material (glass vs metal) and Design (on vs ...

381

RESEARCH MEMORANDUM - NASA Technical Report Server (NTRS)  

Science.gov (United States)

lytical Comparison of Turbine-Blade Cooling System Designed for a. TurboJet Engine Operat- at Supersonic Speed and Altitude. I1 -. Air-C~Oling Systems. ...

382

Preliminary representation of world population by spherical harmonics.  

UK PubMed Central (United Kingdom)

The geographical arrangement of people on the surface of the earth is approximated by a mathematical equation of 361 terms. This is a convenient form for comparison with other distributions and for...Full Text Available

1992-07-15

383

O-Plan2 VS Sipe-2 - A General Comparison  

Science.gov (United States)

... At that time, it seemed obvious to us that the Missionaries and Cannibals puzzle (MC puzzle) would qualify as a simple classical Al planning ...

1994-07-01

385

Land Cover Classification Comparison with Different Resolution ...  

Science.gov (United States)

Dec 9, 2005 ... Classification of high resolution imagery is not as straightforward as more ... The challenges of classifying high resolution imagery stems ...

386

In-situ micro-FTIR study of thermal changes of organics in Tagish ...  

Science.gov (United States)

FT-IR spectroscopic studies of major organic matter in carbonaceous chondrites using microscopic technique and comparison with terrestrial kerogen. ...

387

In vitro activity and human pharmacokinetics of teicoplanin.  

UK PubMed Central (United Kingdom)

The in vitro activity of teicoplanin, a new antibiotic related to vancomycin, was determined against 456 gram-positive cocci. The activity of teicoplanin in comparison with that of vancomycin was similar...Full Text Available

1984-12-01

390

DECEMBER 2002 Paul Menzel - MODIS - NASA  

Science.gov (United States)

A comparison of MODIS Terra regression-based surface skin temperature with that measured by the infrared thermometer (IRT) at the SGP ARM-CART ...

391

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

393

Actinide transmutation in nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.

1993-12-31

394

Actinide transmutation in nuclear reactors  

International Nuclear Information System (INIS)

Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.

1992-09-14

395

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

396

A Comparison of Chinese and American Indian (Chumash) Medicine  

UK PubMed Central (United Kingdom)

Chinese and Chumash traditional medical approaches are similar in terms of disease causation, use of acupuncture or healing touch, plants, spiritual and philosophical approaches. This article provides...Full Text Available

2010-06-01

397
398

Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV  

Energy Technology Data Exchange (ETDEWEB)

The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

1994-07-11

399

Strain differences in the embryotoxicity of "2"3"9Pu  

International Nuclear Information System (INIS)

Comparison of the embryolethality of monomeric "2"3"9Pu injected at 9 days of gestation demonstrated that the sensitivity of Charles River CD strain was greater than that of Hilltop Wistar rats. Subsequent comparisons showed that rats derived from the Hilltop Fischer strain were more sensitive than the Wistar and, although not directly compared, more sensitive than the CD.

1977-05-01

400

On new methods for standardization of samples in activation analysis of biological materials  

International Nuclear Information System (INIS)

New standardization techniques of samples in multielement instrumental neutron-activation analysis (INAA) of biological materials (BM) are considered. New methodical developments of sample preparation techniques, BM tableting, creation of comparison standards and standardization of packing material are suggested. Correlated data on concentration of different elements in standard specimens-comparison standards are presented for mass INAA, that is: for phenol-formaldehyde resin-base and human blood-base synthetic standards. 7 refs.; 3 tabs.

1988-06-26

401

Intracellular activity of the peptide antibiotic NZ2114: studies with Staphylococcus aureus and human THP-1 monocytes, and comparison with daptomycin and vancomycin  

DEFF Research Database (Denmark)

Staphylococcus aureus survives inside eukaryotic cells. Our objective was to assess the activity of NZ2114, a novel peptidic antibiotic, against intracellular S. aureus in comparison with established antistaphylococcal agents acting on the bacterial envelope with a distinct mechanism.

2010-01-01

402

Comparison of ion chromatography and titrimetry for determination of sulfur in fuel oils  

Energy Technology Data Exchange (ETDEWEB)

A comparison was made of Parr bomb ion chromatographic and titrimetric methods to determine sulfur in fuel oils. The two methods are comparable in precision and accuracy. When rapid sulfur determination in a number of samples is desired, the titrimetry method appears to be an appropriate choice between the two methods. l3 tables.

1982-12-01

403

Comparison of calculated and measured irradiated wire data for HEU and mixed HEU/LEU cores in the ORR (Oak Ridge Research Reactor)  

Energy Technology Data Exchange (ETDEWEB)

Low power wire activations are being performed in the Oak Ridge Research Reactor (ORR) as part of the whole-core LEU demonstration experiments. Calculations of the demonstration cores, including simulation of the wire activations, are being performed at Argonne National Laboratory (ANL). This paper presents the results of comparisons for 293 wires from five cores and shows that, on the average, the integrated activities agree within 6%.

1986-01-01

404

Biological network analysis and comparison: mining new biological knowledge  

British Library Electronic Table of Contents (United Kingdom)

The mechanisms underlying life machinery are still not completely understood. Something is known, something is ?probably? known, other things are still unknown. Scientists all over the world are working very hard to clarify the processes regulating the cell life cycle and bioinformaticians try to support them by developing specialized automated tools. Within the plethora of applications devoted to the study of life mechanisms, tools for the analysis and comparison of biological networks are catching the attention of many researchers. It is interesting to investigate why.

2011-01-01

405

Tri-State Synfuels Project Review: Volume 8. Commercial status of licensed process units. [Proposed Henderson, Kentucky coal to gasoline plant; licensed commercial processes  

Energy Technology Data Exchange (ETDEWEB)

This document demonstrates the commercial status of the process units to be used in the Tri-State Synfuels Project at Henderson, Kentucky. The basic design philosophy as established in October, 1979, was to use the commercial SASOL II/III plants as a basis. This was changed in January 1982 to a plant configuration to produce gasoline via a methanol and methanol to gasoline process. To accomplish this change the Synthol, Oil workup and Chemical Workup Units were eliminated and replaced by Methanol Synthesis and Methanol to Gasoline Units. Certain other changes to optimize the Lurgi liquids processing eliminated the Tar Distillation and Naphtha Hydrotreater Units which were replaced by the Partial Oxidation Unit. The coals to be gasified are moderately caking which necessitates the installation of stirring mechanism in the Lurgi Dry Bottom gasifier. This work is in the demonstration phase. Process licenses either have been obtained or must be ...

1982-06-01

406

Tri-State Synfuels Project Review: Volume 8. Commercial status of licensed process units. [Proposed Henderson, Kentucky coal to gasoline plant; licensed commercial processes  

Science.gov (United States)

This document demonstrates the commercial status of the process units to be used in the Tri-State Synfuels Project at Henderson, Kentucky. The basic design philosophy as established in October, 1979, was to use the commercial SASOL II/III plants as a basis. This was changed in January 1982 to a plant configuration to produce gasoline via a methanol and methanol to gasoline process. To accomplish this change the Synthol, Oil workup and Chemical Workup Units were eliminated and replaced by Methanol Synthesis and Methanol to Gasoline Units. Certain other changes to optimize the Lurgi liquids processing eliminated the Tar Distillation and Naphtha Hydrotreater Units which were replaced by the Partial Oxidation Unit. The coals to be gasified are moderately caking which necessitates the installation of stirring mechanism in the Lurgi Dry Bottom gasifier. This work is in the demonstration phase. Process licenses either have been obtained or must be ...

1982-06-01

407

Stability analysis based on expanded displacement method for pile foundations; Kakucho hen`iho ni yoru kui kiso no jitsuyo antei keisanho ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

Method is proposed for expanding the pile foundation elastic analysis method (displacement method) to cover a larger displacement region, and its appropriateness is verified by a field test. In this report, stability calculation is discussed in which the present displacement method is expanded by assuming an equivalent plastic hinge on the pile head and by replacing the soil spring in the large displacement region with an equivalent linear elastic spring. A static horizontal loading test is conducted for a foundation using a real pile, which is an application of this method. On the assumption that a hinge is generated on the pile head, the pile spring constant of the current displacement method is replaced with a value that takes into consideration the plastic hinge region, and this enables the analysis of pile behavior even after breakdown. This method is applied to the result of a loading test using a real foundation, and it is found that it ...

1997-06-21

408

Scintigraphical observation of femoral head in femoral neck fractures  

International Nuclear Information System (INIS)

In IO cases of femoral neck fracture treated with prosthetic replacement, the preopera tive sup(99m)Tc-MDP scintigraphs were investigated and then compared with each histological findings of the extracted femoral head. The appearances of the scintigraphs were classified into following 3 patterns; increased activity pattern of sup(99m)Tc-MDP uptake in the overall femoral head (type I) in 4 cases, deficient activity pattern at the lateral side correspond to weight-bearing area (type II) in 2 cases and considerably deficient activity pattern in the whole femoral head (type III) in remaining 4 cases. Histological examination of the extracted femoral heads revealed the narrow part of ischemic necrosis in type I. However type II showed extensive necrosis in the portion of deficient activity by scintigraphs and in type III, the femoral heads except articular cartilage were entirely necrotic. This classification of sup(99m)Tc-MDP scintigraphy is correlated with the degree ...

409

Safety analysis program for steam generators replacement and power uprate at Tihange 2 nuclear power plant  

International Nuclear Information System (INIS)

The Belgian Tihange 2 nuclear power plant went into commercial operation in 1983 producing a thermal power of 2785 MW. Since the commissioning of the plant the steam generators U-tubes have been affected by primary stress corrosion cracking. In order to avoid further degradation of the performance and an increase in repair costs, Electrabel, the owner of the plant, decided in 1997 to replace the 3 steam generators. This decision was supported by the feasibility study performed by Tractebel Energy Engineering which demonstrated that an increase of 10% of the initial power together with a fuel cycle length of 18 months was achieved. Tractebel Energy Engineering was entrusted by Electrabel as the owner's engineer to manage the project. This paper presents the role of Tractebel Energy Engineering in this project and the safety analysis program necessary to justify the new operation point and the fuel cycle extension to 18 months re-analysis of FSAR chapter 15 accidents ...

2002-08-11

410

Replacement of nickel sealing rings by expanded graphite sealing rings -upgrading of SG primary collector flange connection  

Energy Technology Data Exchange (ETDEWEB)

One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation experience proved relatively low service of bolts, damage of thread holes and ...

1997-12-31

411

Replacement of leucine-93 by alanine or threonine slows down the decay of the N and O intermediates in the photocycle of bacteriorhodopsin: Implications for proton uptake and 13-cis-retinal----all-trans-retinal reisomerization  

Energy Technology Data Exchange (ETDEWEB)

The authors report that the replacement of Leu-93 in bacteriorhodopsin by Ala (L93A) or Thr (L93T) slows down the photocycle by approximately 100-fold relative to wild-type bacteriorhodopsin. Time-resolved visible absorption spectroscopy and resonance Raman experiments, respectively, show the presence of long-lived O-like and N-like intermediates in the photocycles of the above mutants. We infer the existence of an equilibrium between the N and O intermediates in the photocycles of these mutants. The L93A and L93T mutants exhibit normal proton pumping under continuous illumination, suggesting that the decay of the N and/or O intermediate, and consequently, proton translocation, can be accelerated by the absorption of a second photon. Since the 13-cis----all-trans reisomerization of retinal is completed during the decay of the N and O intermediates, they conclude that the interaction of Leu-93 with retinal is important in this phase of the photocycle. This ...

1991-08-01

412

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in ...

2006-11-13

413

Problems encountered in welding Inconel 625 bridgewire material  

Energy Technology Data Exchange (ETDEWEB)

Welding problems occurred while resistance welding Inconel 625 to Inconel 600 pins in the MC3462A header at Unidynamics/Phoenix (UPI). The bridgewire showed transverse and longitudinal cracks, a condition called hot cracking, at the weld area. Welding studies at Mound confirmed a best effort could not produce welds without hot cracking. Two new bridgewire materials, Tophet C and Alloy 800, were then introduced to replace Inconel 625. Samples of both bridgewired headers welded at Unidynamics were studied at Mound to determine which was the better material. Results showed that Alloy 800 was subject to the same hot cracking phenomenon as Inconel 625, whereas all samples of Tophet C except one showed no cracks. The only Tophet C sample showing cracks showed only minor cracks. Langley tests performed with Tophet C as the bridgewire showed that the no-fire characteristics can be met. Tophet C was therefore chosen to replace Inconel 625.

1982-05-10

414

Paleo-botanical evidence for ecosystem disruption at the Cretaceous-Tertiary boundary from Wood Mountain, Saskatchewan, Canada  

Energy Technology Data Exchange (ETDEWEB)

A continuous, subsurface Cretaceous-Tertiary boundary section, including the boundary clay within an 87 cm thick lignite, has been recovered from a core hole near Wood Mountain, Saskatchewan, Canada. The lignite-encompassed clay layer with geochemical anomaly indicates that peat deposition was continuous across the boundary. Core data indicate that, locally, a pre-boundary, conifer-dominated swamp was abruptly replaced by an angiosperm-dominated, herbaceous wetland. Sudden extermination of the dominant forest elements indicates mass kill at the level of the boundary and supports the theory of extraterrestrial impact accompanied by catastrophic destruction. Devastation of the standing vegetation may have been caused by one or more of the killing agents predicted to have accompanied impact, including freezing temperatures caused by atmospheric dust, acid rain, thermal pulse, and shock waves. There is no evidence supporting wildfires as a killing agent. Vegetational ...

1999-05-01

415

News from the world; Echos du monde  

Energy Technology Data Exchange (ETDEWEB)

This document gathers a series of very short articles concerning nuclear industry around the world. Areva company is investing 30 million euros in its Chalon-Saint-Marcel plant, it is the consequence of the extension of service life of nuclear power plants in the Usa. Areva holds 40% of the American market concerning the replacement of steam generators and 50% of that concerning the replacement of closure heads. The Obrigheim nuclear power plant was definitely closed down on may 2004, this decommissioning is a step forward in the German policy of progressively stepping out of nuclear energy. Chinese authorities are willing to construct 40 nuclear reactors in 15 years, despite that, the contribution of nuclear energy to the generation of electricity will reach only 4% in 2020. In 2007 Cea will begin the construction works of a new research reactor (Jules Horowitz reactor) in the Cadarache site. Prices of the yellow cake have been going up during ...

2005-04-01

416

Measures for reliability improvement of on-site power plant at steel works  

Energy Technology Data Exchange (ETDEWEB)

This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in separate sections of the facilities which are divided in ...

1988-04-15

417

Low-temperature brown rice storage by using renewable energy from snow  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of stored rice was almost similar to that of freshly harvested rice. The study showed that renewable energy generated from snow ...

2010-07-01

418

Looking back on 30 years of experience in the decontamination of radioactive, liquid effluents at KfK. The vapour compression evaporator, for example; 30 Jahre Abwasserdekontamination KfK, Erfahrung mit Bruedenkompressionsverdampfern  

Energy Technology Data Exchange (ETDEWEB)

The first equipment installed at KfK-HDB was a system with a thin-film evaporator. This was later replaced by two vapor compression evaporating units with forced circulation, for evaporation of liquid LAW, and a steam-heated natural circulation evaporator, for evaporation of liquid MAW. Nuclear activities of the Karlsruhe Nuclear Research Center phasing out, the liquid radwaste quantities to be treated have been shrinking accordingly, so that the current system is planned to be replaced by a smaller system with a thin-film evaporator. (orig./HP) [Deutsch] Im Laufe der Jahre wurde die Anlage mit Duennschichtverdampfer durch zwei Bruedenkompressionsverdampfer mit Zwangsumwaelzung fuer die Eindampfung leicht aktiver waessriger Abfaelle und einem dampfbeheizten Naturumlaufverdampfer fuer die Eindampfung mittelaktiver waessriger Abfaelle ersetzt. Mittlerweile sinkt der Abwasseranfall seit Jahren stetig aufgrund der sinkenden Aktivitaeten des ...

1994-05-01

419

Innovative coke oven gas cleaning system for retrofit applications. Quarterly environmental monitoring report No. 1, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia ...

1992-08-24

420

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia ...

1992-08-24

421

Environmental assessment of the brine pipeline replacement for the Strategic Petroleum Reserve Bryan Mound Facility in Brazoria County, Texas  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0804, for the proposed replacement of a deteriorated brine disposal pipeline from the Strategic Petroleum Reserve (SPR) Bryan Mound storage facility in Brazoria County, Texas, into the Gulf of Mexico. In addition, the ocean discharge outfall would be moved shoreward by locating the brine diffuser at the end of the pipeline 3.5 miles offshore at a minimum depth of 30 feet. The action would occur in a floodplain and wetlands; therefore, a floodplain/wetlands assessment has been prepared in conjunction with this EA. Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969 (42 USC. 4321, et seg.). Therefore, the preparation of an Environmental Impact Statement (EIS) is not required, and the Department ...

1993-09-01

422

Electroweak Supersymmetry with an Approximate U(1)_PQ  

CERN Document Server

A new predictive framework for supersymmetry at the TeV scale is presented. The \\mu parameter of the MSSM is replaced by (\\lambda S), where S is a singlet field, and the axion becomes a heavy pseudoscalar, G, by adding a mass, m_G, by hand. The explicit breaking of Peccei--Quinn (PQ) symmetry is assumed to be sufficiently weak at the TeV scale that the only observable consequence is the mass m_G. Three models for the explicit PQ breaking are given; but the utility of this framework is that the predictions for all physics at the electroweak scale are independent of the particular model for PQ breaking. The MSSM parameters \\mu, B are replaced by \\lambda, A_\\lambda. Taking the scalar mass m_S^2 to be sufficiently small and \\lambda = A_\\lambda \\sin (2 \\beta) /2. Our framework leads to a theory similar to the MSSM, except that \\mu is predicted and there are light, weakly-coupled states that lie dominantly in the superfield S. The ...

2004-01-01

423

Effect of prolactin on the attractiveness of male odors to females in meadow voles: independent and additive effects with testosterone.  

Science.gov (United States)

This study investigated the roles of testosterone and prolactin in seasonal changes in the attractiveness of odors of male meadow voles to long-photoperiod females. Prolactin was reduced in long-photoperiod males by treatment with bromocryptine (Experiment 1) and increased in short-photoperiod males by replacement with ovine prolactin (Experiment 2). Testosterone was manipulated by castration and testosterone replacement. During long photoperiods, the attractiveness of the odor produced by male meadow voles depends on the circulating titers of both prolactin and testosterone. Males with high titers of both hormones produced scents that were highly attractive to females; those with low titers of both hormones produced unattractive scents. When the concentration of one hormone was high and the other low, long-photoperiod males produced scents of intermediate attractiveness. During short photoperiods, the attractiveness of the male's scents ...

1997-02-01

424

Effect of Cr content, hardness and micro structure on flow-accelerated corrosion in carbon steel pipes. Examination of replaced carbon steel pipes  

International Nuclear Information System (INIS)

68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not correlated with wall thinning rate. (3) The micro structure was ...

2008-10-01

425

Bilateral femoral neck fractures following pelvic irradiation  

International Nuclear Information System (INIS)

Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was found out, but thickness of the internal ...

426

Alteration of installation of reactors (alteration of No. 1 and No. 2 reactor facilities) in the Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The Nuclear Safety Commission presented the report to the Minister of International Trade and Industry on April 5, 1984, after the careful investigation and deliberation on the alteration of installation of No.1 and No.2 reactor facilities in the Sendai Nuclear Power Station. The technical capability of Kyushu Electric Power Co., Inc., was recognized to be adequate. It was judged that the safety after this alteration of installation of the reactor facilities can be ensured. The main items of examination were as follows. The mechanical, nuclear and thermo-hydraulic designs of 17 x 17 B-type fuel assemblies were regarded as adequate. The coexistence of A-type and B-type fuel assemblies does not cause any problem about the safety. The safety at the time of abnormal transient change and accident in the mixed fuel assembly core was confirmed. In No.2 reactor, the degree of enrichment of the fuel for replacement and the number of fuel assemblies to be ...

1984-08-01

427

Comparison of blade materials for a small stall controlled turbine. Vergelijking van bladmaterialen voor een kleine overtrekgeregelde turbine  

Energy Technology Data Exchange (ETDEWEB)

This report surveys the possibilities and restrictions of different construction materials for the purpose of the blades of a small stall regulated turbine. For example scaling up, material saving at decreasing of static or dynamic loads, comparisons of global costs based on prices per unit of weight, etc. For the mutual comparison of construction materials for turbine blades the starting point is a stall regulated horizontal axis turbine with a rotor diameter of 16 m and a tipvane speed of about 64 m/s. Short descriptions are given of the materials and of the applied production methods with the resulting blade geometry. The blade skins are dimensionized for storm loads after the optimalization of the blade geometry, needed for the design wind speed, is recorded. The resulting blade skins are mutually compared as for weight, mass inertia and bending stiffness. Also a comparison took place of the resulting reserve factors ...

1988-02-01

428

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

2008-10-15

429

Waste management considerations for fusion power reactors  

International Nuclear Information System (INIS)

To estimate the waste management needs of a fusion power reactor, a scheme for handling radioactive waste from a fusion plant has been devised. The handling scheme proceeds with radioactive waste, primarily from blanket replacement, being stored on-site; waste in cooled and shielded casks is then isolated off-site; finally, the materials are recycled. Using activities and component lifetimes supplied by designers, several conceptual fusion power reactors have been analyzed and their waste streams compared to fission reactors with regard to total activity, specific activity, and lifetimes of activity.

430

Waste management considerations for fusion power reactors  

Science.gov (United States)

To estimate the waste management needs of a fusion power reactor, a scheme for handling radioactive waste from a fusion plant has been devised. The handling scheme proceeds with radioactive waste, primarily from blanket replacement, being stored on-site; waste in cooled and shielded casks is then isolated off-site; finally, the materials are recycled. Using activities and component lifetimes supplied by designers, several conceptual fusion power reactors have been analyzed and their waste streams compared to fission reactors with regard to total activity, specific activity, and lifetimes of activity.

1978-02-01

431

Understanding and protecting steam generator materials  

Science.gov (United States)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-01-01

432

Understanding and protecting steam generator materials  

International Nuclear Information System (INIS)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-11-16

433

The need for action in the housing ventilation area is essential; Bei der Wohnungslueftung besteht grosser Handlungsbedarf  

Energy Technology Data Exchange (ETDEWEB)

This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.

2003-07-01

434

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

435

Steam turbines. Calculation, construction, partial performance and performance in service, condensation. Dampfturbinen. Berechnung, Konstruktion, Teillast- und Betriebsverhalten, Kondensation  

Energy Technology Data Exchange (ETDEWEB)

All sections of the third edition of this well-known textbook have been revised and enlarged in consequence of the change-over to SI units. Numerous examples and illustrations have been included or replaced by new ones. The book considers the latest research results as well as the constructive developments of industrial steam turbine construction. On a scientific basis, this plain book imparts basic knowledge of the design, calculation, execution, condensation and performance in service of steam turbines of all types. The well-founded introduction, together with many calculated examples addresses the student as well as the engineer.

1980-01-01

436

Singularities and Closed String Tachyons  

Energy Technology Data Exchange (ETDEWEB)

A basic problem in gravitational physics is the resolution of spacetime singularities where general relativity breaks down. The simplest such singularities are conical singularities arising from orbifold identifications of flat space, and the most challenging are spacelike singularities inside black holes (and in cosmology). Topology changing processes also require evolution through classically singular spacetimes. I briefly review how a phase of closed string tachyon condensate replaces, and helps to resolve, basic singularities of each of these types. Finally I discuss some interesting features of singularities arising in the small volume limit of compact negatively curved spaces and the emerging zoology of spacelike singularities.

2006-03-17

437

Single parameter analysis of hysteretic magnetic flux trapping in high T{sub c} superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-10-01

438

Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon  

International Nuclear Information System (INIS)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-07-19

439

Single parameter analysis of hysteretic magnetic flux trapping in high T[sub c] superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-01-01

440

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

441

Reaction pathways of the dissociation of methylal: A DFT study  

Energy Technology Data Exchange (ETDEWEB)

Schemata for modelling combustion processes do not yet include reaction rates for oxygenated fuels like methylal (DMM) which is considered as an additive or replacement for diesel due to its low sooting propensity. Density functional theory (DFT) studies of the possible reaction pathways for different dissociation steps of methylal are presented. Cleavage of a hydrogen bond to the methoxy group or the central carbon atom were simulated at the BLYP/6-311++G{sup **} level of theory. The results are compared to the experiment when dissociating and/or ionising DMM with femtosecond pulses. (author) 1 fig., 1 tab., 1 ref.

1999-08-01

442

Radiation and thermal analysis of superconducting quadrupoles in the interaction region of linear collider  

Energy Technology Data Exchange (ETDEWEB)

CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.

2008-06-01

443

Oral histories at the Hanford Nuclear Reservation  

Energy Technology Data Exchange (ETDEWEB)

The founding of the Hanford Engineering Works to produce plutonium is described. The 45-year defense mission has now been replaced with a peaceful mission, that of being the first site for massive cleanup of the 45-year nuclear waste. In order to establish a remedial investigation and feasibility plan, a process of discovery named the Technical Baseline Report must be performed; the task of this process is to discover all that is known about a proposed cleanup site (what the waste was, where did it go). When none of the documentation can answer the question, oral history is utilized. Some of the problems associated with the conduct of oral history interviews are described, particularly Hanford`s legacy of secrecy.

1992-03-01

444

Open-pit explosives  

Energy Technology Data Exchange (ETDEWEB)

This paper explains how mine operators are taking a closer look at the power of explosives and how primary breakage affects other open-pit mining costs. Slurries have overcome most of the disadvantages attributed to them in their early years and may replace Anfo. Effective blasting is the key to an efficient, low-cost mining operation. Reviews are presented on research in crater studies, computer-aided design, the expanding gas theory, and high-speed motion picture cameras that show the importance of shock energy in fracturing the rock interfaces throughout the burden. The paper concludes with MSHA-approved courses in blasting offered throughout the US.

1982-07-01

445

Nuclear fuel assembly identification using computer vision  

Science.gov (United States)

This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.

1985-11-01

446

Nonrelativistic reduction and interpretation of the Klein-Gordon equation of tachyons  

International Nuclear Information System (INIS)

A one-dimensional tachyon Klein-Gordon equation is reduced to a nonrelativistic-tachyon equation of motion. The interpretation of this reduced equation leads to the following conclusions: 1) tachyons can be localized in time instead of in space as compared with bradyons, 2) space representation and momentum representation of bradyonic quantum equation of motion are replaced by time representation and energy representation in tachyon quantum equation of motion and 3) with the aid of these results, it has been found that the solutions of the tachyon Klein-Gordon equation of motion form a complete set. (author).

447

Natural convection cooling of circumferentially finned transport casks  

International Nuclear Information System (INIS)

It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.

1983-12-01

448

Moving toward personalized cell-based interventions for adrenal cortical disorders: Part 2 - Human diseases and tissue engineering  

British Library Electronic Table of Contents (United Kingdom)

Transdifferentiation of an individual's own cells into functional differentiated cells to replace an organ's lost function would be a personalized approach to therapeutics. In this two part series, we will describe the progress toward establishing functional transdifferentiated adrenal cortical cells. In this article (Part 2), we describe the disorders of the adrenal cortex, therefore establishing why there is the need for personalized cell-based therapy for individuals with these disorders. We then present our pilot studies of cell transdifferentiation toward an adrenal cortical fate using genes described in the first article of this pair (Part 1).

2011-01-01

449

Moving toward personalized cell-based interventions for adrenal cortical disorders: Part 1 - Adrenal development and function, and roles of transcription factors and signaling proteins  

British Library Electronic Table of Contents (United Kingdom)

Transdifferentiation of an individual's own cells into functional differentiated cells to replace an organ's lost function would be a personalized approach to therapeutics. In this two part series, we will describe the progress toward establishing functional transdifferentiated adrenal cortical cells. In this article (Part 1), we describe adrenal development and function, and discuss genes involved in these processess and selected for use in our pilot studies of transdifferentiation that are presented in the second article (Part 2).

2011-01-01

450

Luminescence characteristics of LiCaAlF6:Eu phosphor  

British Library Electronic Table of Contents (United Kingdom)

A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2007-01-01

451

Life management of power plant based on structural damage testing  

Energy Technology Data Exchange (ETDEWEB)

Life management system is based on the valid nowadays in Estonian power plants regulation documentation. The system allows to estimate stress distribution in components, find computational assessment of cumulated creep damage, determine when and where it is necessary to cut off the particular number of microsamples or take replicas. Finally, the real metal condition may be assessed on the basis of metallographic specimen research and reasonable 3-R decision - run, repair, replacement - made on further component use. (orig.) 6 refs.

1998-12-31

452

Lead oxides-lithium cells  

Science.gov (United States)

The possibility of using lead and lead-bismuth mixed oxides as positive active materials in organic electrolyte lithium cells with a working voltage similar to those of silver zinc cells has been considered. Button cells of SR 44 size have been developed as a test vehicle and studied under various conditions of discharge rate and storage. This paper describes the performance characteristics obtained under these conditions and suggests in conclusion the possible replacement of silver zinc cells by such systems for a large range of low-rate applications on the basis of cost effectiveness.

1979-01-01

453

Kevlar, the 'universal fiber'. Properties and applications in industry, sports and recreation. Kevlar - die 'Alleskoenner-Faser'. Eigenschaften und Anwendung in Industrie, Sport und Freizeit  

Energy Technology Data Exchange (ETDEWEB)

This article gives a survey of the history, properties and applications of 'Kevlar' aramide fibers. For example, the 'Kevlar' para-aramide fiber is used in compound materials in ship-, aircraft- and vehicle construction. 'Kevlar' is used as a replacement for asbestos, for example in brakes, clutches and seals or as rubber reinforcement (tyres, conveyor belts, hoses). The aramide fibers also offer manufacturers of ropes, hawsers and cables a near ideal range of properties. (MM).

1988-12-01

454

Integration of direct solar steam collectors in steam cycle power plants; Einkopplung von direktverdampfenden Parabolrinnenkollektoren in Dampfkraftwerke  

Energy Technology Data Exchange (ETDEWEB)

The restricted temperature stability of the synthetic thermal oil which is used as heat carrier fluid in parabolic trough collectors so far limits the live steam parameters in the steam cycle to approximately 375 Celsius. In order to break through this limit, already for quite some time it is researched to replace the thermal oil by boiler feeding waters and to accomplish the evaporation in the collectors. The contribution under consideration gives an overview on the direct evaporation concept and summarizes the past operational experiences. Moreover, the challenges with the integration of this technology in a steam turbine cycle are elaborated.

2008-07-01

455

Industrial processing of complex fluids: Formulation and modeling  

Energy Technology Data Exchange (ETDEWEB)

The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.

1997-08-01

456

Increased use of natural gas has positive effects for the environment  

International Nuclear Information System (INIS)

Increased use of natural gas has positive effects for the environment and the climate, because it primarily replaces petroleum products. Moreover, the natural gas does not pose a threat to bio fuel in Norway. But introducing CO2 taxes on natural gas will significantly increase the emission of greenhouse gases, concludes a report conducted by Norsk Energi (Norwegian Energy) on behalf of Norsk Naturgassforening (Norwegian Natural Gas Association) and Norsk Gassforum (Norwegian Gasforum). A brief presentation of the main conclusions in the report (ml)

2006-01-01

457

In situ monitoring of grouted electrolytes  

Energy Technology Data Exchange (ETDEWEB)

Cement-based composites are widely used in applications which demand long-term service life. One important example is in immobilization matrices for low-level radioactive and other hazardous wastes, which demands long-term retention and durability. The authors describe conductivity measurements of grouts flooded with water and in contact with a sink that consists of pure water. The conductivity measurements were designed and carried out in parallel with present quality verification methods and standard leach tests of the nuclear waste management industry. For the first time, the authors show that the method of replacing intrusive chemical analysis with conductivity measurements of the leaching samples yields equivalent results.

1996-04-01

458

Improved four-stage accel-decel production of low energy highly stripped heavy ions  

Energy Technology Data Exchange (ETDEWEB)

The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.

1983-04-01

459

Fourth international seminar on horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

The general objective of the International Seminars of Horizontal Steam Generator Modelling has been the improvement in understanding of realistic thermal hydraulic behaviour of the generators when performing safety analyses for VVER reactors. The main topics presented in the fourth seminar were: thermal hydraulic experiments and analyses, primary collector integrity, feedwater distributor replacement, management of primary-to-secondary leakage accidents and new developments in the VVER safety technology. The number of participants, representing designers and manufacturers of the horizontal steam generators, plant operators, engineering companies, research organizations, universities and regulatory authorities, was 70 from 10 countries.

1997-12-31

460

Estimation of armature condition in concrete with gamma-absorption method  

International Nuclear Information System (INIS)

Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers

461

Entrained Solids, Strontium-Transuranic Precipitation, and Crossflow Filtration of AN102 Small C  

Energy Technology Data Exchange (ETDEWEB)

This work is the first active crossflow filter testing of the new strontium-permanganate process for Envelope C at the Savannah River Technology Center. Extreme filtration difficulties with the ferric hydroxide precipitation led to investigations of other chemistries with simulants. The current process includes the isotopic dilution by precipitation from inactive strontium nitrate addition. A permanganate strike to replace ferric reagents was found to provide practical filterability and good lanthanide or transuranic decontamination. That work had been supported with simulant and active beaker testing.

2000-09-27

462

Deploying innovative technologies to improve DOE D&D project baselines  

Energy Technology Data Exchange (ETDEWEB)

The insertion of innovative technologies to replace baseline technologies used in cost estimation and planning of DOE D&D projects is considered a high risk endeavor by project and programmatic decision makers. It is almost always considered safer to go with the {open_quotes}devil you know{close_quotes} than use a new or untried technology, methodology or system. The decision on the specific technology to be utilized to remediate a problem is often made months or years in advance of execution, and the highly proscriptive documentation of agreements necessary to obtain stakeholder and regulator approval of remedial plans is often counterproductive to considering improved technologies.

1997-05-01

463

Database management system for instrument data management  

Energy Technology Data Exchange (ETDEWEB)

Data from many measuring devices throughout the Savannah River Site (SRS) is transmitted to a central location for processing as a vital component in the SRS emergency preparedness and response program. The data processing is currently accomplished using VAX-based FORTRAN programs with the data stored in Digital's Record Management System (RMS) files which is shared using global COMMON. A program is underway to store and process this data using a Structured Query Language (SQL)-based Database Management System (DBMS). The advantages of replacing the current system with one using an SQL-based DBMS are discussed.

1990-01-01

464

DOE reports on feasibility of generic oil shale test facility  

Energy Technology Data Exchange (ETDEWEB)

In order to assess whether an oil shale test facility would be of significant use to private sector oil shale developers, the US DOE has studied the past history of oil shale development and its potential for replacing petroleum supplies. A generic test facility's primary function would be to test concepts of mining, retorting, upgrading, and environmental aspects at the engineering scale. This paper summarizes the US oil shale resources, gives a technology analysis, and discusses the potential for a test facility.

1987-03-01

465

Clones to replace forest seedlings  

Energy Technology Data Exchange (ETDEWEB)

A considerable time can elapse between initial selection of candidate plus trees and harvest of improved seed. The technique showing the greatest promise of shortening this interval is vegetative propagation. Stock plants are grown for two years from seed before the first propagation cycle begins and each plant can be bulked-up 300-500 times over two cycles. An initial stock of 2500 superior Sitka Spruce plants can be multiplied to yield between 300,000 and 750,000 rooted cuttings for forest use within four years from the start of propagation.

1985-01-01

466

Canadian nuclear review  

International Nuclear Information System (INIS)

Progress in the construction of Candu reactors at home and abroad is surveyed. Some A.E.C.L. research projects are also mentioned. During 1979, Candu reactors again showed their superior capacity factors, four of them being among the ten most reliable reactors in the world. Progress in construction at Pickering B, Bruce B, Point Lepreau, Gentilly-2, Darlington, Wolsung (Korea), Cordoba (Argentina), and Cernavoda (Romania) is recounted. In 1979, it was unfortunately necessary to replace installed steam generators at Pickering B, Bruce B, Point Lepreau and Gentilly-2. At Wolsung, the reactor was pre-assembled before installation, which is a new technique. (N.D.H.).

1979-01-01

467

CT-pathologic correlation of focal area of ground-glass attenuation (GGA) in the peripheral lung  

Energy Technology Data Exchange (ETDEWEB)

We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)

2001-07-01

468

Advances and innovations in dialysis in the 21st century.  

Science.gov (United States)

Patients with end stage renal failure (ESRD) require renal replacement therapy in the form of dialysis or renal transplantation. There is an increasing number of people receiving maintenance dialysis as patients with ESRD are increasing faster than the supply of transplantable organs. The mortality rate on dialysis is 4-6 times that of the general population and is substantially reduced by transplantation. For the past 8 years, dialysis research has focused on improving patient outcomes and quality of life on dialysis. This review examines recent advances in haemodialysis and peritoneal dialysis in a historical context and considers future research possibilities. PMID:19329705

2009-02-01

469

A simplified proof of the relation between scaling exponents in first-passage percolation  

CERN Document Server

In a recent breakthrough work, Chatterjee proved a long standing conjecture that relates the transversal exponent \\xi and the fluctuation exponent \\chi in first-passage percolation on Z^d. The purpose of this paper is to introduce a new and intuitive idea that replaces Chatterjee's main argument and gives an alternative proof of this relation. Specifically, we show that under the assumption that exponents (as defined by Chatterjee) exist, one has the relation \\chi \\leq 2\\xi -1. One advantage of our argument is that it does not require a `nearly Gamma' assumption on the edge-weight distribution.

2011-01-01

470

A multilayered acoustic hyperlens with acoustic metamaterials  

British Library Electronic Table of Contents (United Kingdom)

The acoustic hyperlens can be realized by an alternating layered structure of water and fluid with negative mass density. Based on this alternating layered principle, we propose that an acoustic metamaterial consisting of three layers in water background can be designed to replace the fluid with negative mass density. The effective mass density and bulk modulus of the system which is composed of acoustic metamaterial and water are functions of the frequency. The effective mass density of such a system is close to the negative mass density of the fluid at a specific frequency; thus an acoustic metamaterial hyperlens can be achieved.

2011-01-01

471

A framework for the financial evaluation of household biogas plants in India  

Energy Technology Data Exchange (ETDEWEB)

A generalised procedure for quantifying the benefits of household biogas plants is presented. The sensitivity of the procedure to the uncertainty in input prices is reduced through the assumption of incremental benefits from the biogas plant. These benefits are quantified in terms of the quantity of fuelwood for which the biogas substitutes in cooking, the quantity of kerosene replaced through the use of biogas for lighting and the diesel fuel displaced through the use of a biogas fuelled dual-fuel engine for motive power. Sensitivity of the monetary benefits for these parameters is examined in order to identify variables which influence the viability of the technology to the end user. (author).

1990-01-01

472

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

473

Visualization and measurement of pressurized multiphase flow using neutron radiography of JRR-3M system  

Energy Technology Data Exchange (ETDEWEB)

Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in ...

1998-01-01

474

Utilization of emulsified rapeseed oil in a direct injection diesel engine; Chokufunshiki diesel kikan deno nataneyu nyuka nenryo no riyo  

Energy Technology Data Exchange (ETDEWEB)

With an objective to use reproducible vegetable oil as a substitute fuel, studies were performed to use emulsified rapeseed oil at an optimal mixing ratio with water in a direct injection diesel engine. The experiment used a water cooled, lateral installation, single-cylinder, direct injection, four-cycle diesel engine, and the tested fuel used an emulsified rapeseed oil fuel with rapeseed oil added with water at a rate of 20% by weight. As a result of the experiment using the emulsified rapeseed oil, it was found that reducing the injection opening diameter smaller than the standard opening diameter improves the engine performance and simultaneously reduces concentrations of HC, CO and exhaust smoke. The optimal opening diameter was about 0.22 mm. Increasing the valve opening pressure reduced the NOx concentration, but increased the HC concentration. Using the emulsified rapeseed oil fuel accumulated more carbon below the head, but much smaller amount on the ...

1994-09-30

475

Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to ...

2008-11-15

476

The year 2000 embedded systems problem to maintain the safety of nuclear installations  

International Nuclear Information System (INIS)

The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a valve, may control the flow of cooling system to reactor core. Embedded systems in our organization are also be found in Batan ...

1999-02-01

477

The effects of Al{sub 2}O{sub 3}-TiO{sub 2} coating in a diesel engine on performance and emission of corn oil methyl ester  

Energy Technology Data Exchange (ETDEWEB)

Today, as a result of increase in oil prices, limited fossil fuel resources, environmental consideration and global warming, the methyl ester fuels have been focused on alternative fuels. Methyl ester fuels can be used more efficiently in low heat rejection engines (LHR), in which the temperature of combustion chamber is increased by creating a thermal barrier. In this study, the piston, cylinder head, exhaust and inlet valves of a diesel engine were coated with the ceramic material Al{sub 2}O{sub 3}-TiO{sub 2} by the plasma spray method. Thus, a thermal barrier was provided for the parts of the combustion chamber with these coatings. The effects of corn oil methyl ester that produced by the transesterification method, and No. D2 fuels' performance and exhaust emissions' rate were studied by using equal in every respect coated and uncoated engines. Tests were performed on the uncoated engine, and then repeated on the coated engine and the results ...

2010-10-15

478

Study on the application of a geothermal heat pump; Etude sur l`application d`une pompe a chaleur geothermique  

Energy Technology Data Exchange (ETDEWEB)

The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, which is very low compared to the consumption of electric heating (0.286 GJ per sq.m) or oil heating (0.419 GJ per sq.m). 4 figs., 1 tab.

1996-12-01

479

Sealing of nuclear plant electrical equipment: Final report  

International Nuclear Information System (INIS)

The nuclear power industry has many applications where electrical equipment is required to operate in environments which contain high relative humidity, steam and water or chemical sprays. Equipment is susceptible to these environments by moisture entering through inherent design provisions such as O-rings and through the electrical interface. The objective of this research is to review electrical interface sealing techniques and to recommend methods for providing effective electrical interface sealing. The most common methods of sealing are the use of electrical fittings containing sealants, add-on assemblies and hardware changeout. The experience gained in several years of testing electrical interface seals on such devices as limit switches, solenoid valves and transmitters is presented to provide information on seal effectiveness and preferred application. The effectiveness of various sealing methods is discussed, each of which is dependent upon the device being ...

480

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of radiation dose equivalent based ...

1990-03-01

481

Reduction of nitrogen oxides (NO{sub x}) production in a liquid fuel-oil diffusion flame by acoustic excitation; Reduction de la production des oxydes d`azote (NO{sub x}) dans une flamme de diffusion a fioul liquide par excitation acoustique  

Energy Technology Data Exchange (ETDEWEB)

The control of nitrogen oxides (NO{sub x}) emissions will become a major challenge in the forthcoming years, in the domain of automotive industry or industrial burners. Pulsed combustion offers an imaginative solution which does not affect the combustion efficiency. In this paper, the efficiency of this method is demonstrated using the burner of a 20 kW domestic boiler. The actuator is simply installed on the air intake. Two types of actuators have been tested successfully: a loudspeaker and a rotative valve. Both can produce 100 to 1000 Hz frequencies and can lead to a reduction of 20% of NO{sub x} emissions. The feasibility of the concept is also demonstrated on a 840 kW liquid fuel-oil burner. The mechanisms involved during an excitation are explained using the CH{sup *} radical imaging. Results show an important reorganization of the flow and of the flame structure. During each excitation cycle, an annular swirl occurs at the leading edge of the flame catching ...

1996-12-31

482

Recent increased use of polybutylene terephthalate (PBT) resin in automotive field. Jidosha bun prime ya de kinnen kakudai shimesu PBT jushi  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation grade is wanted. Valves for exhaust control require high-temperature rigidity, ...

1992-06-18

483

Preliminary Guideline for the High Temperature Structure Integrity Assessment Procedure Part I. High Temperature Structure Design Guide  

Energy Technology Data Exchange (ETDEWEB)

A preliminary guideline for the design and evaluation of LMR high temperature structure is presented based upon ASME B and PV Code, Section III, Subsection NH. The main contents of this guideline are the materials, general design, vessel, piping, core support structure, pumps, valves, fabrication, examination, and testing for the class 1 components. The ratcheting evaluation, enhanced creep assessment, welds design and evaluation, inelastic analysis approach, piping design alternatives, and bellows design method are described in appendices. A user of this guideline should follow the essential procedures and may refer to other pertinent codes, standards, laws, regulations, or other pertinent documents when this guideline does not lead to proper design of the structure. While this guideline adopts major procedures of Subsection NH, it refers to the RCC-MR and/or DDS in some amount for the items where these codes have excellency to improve this guideline.

2007-02-15

484

Methane gas engine  

Energy Technology Data Exchange (ETDEWEB)

The fuel-injection system of the Niigata 6L 16X-AG dual-fuel engine is structured to steadily supply injected fuel during diesel-engine operation, and to distribute oil at a low rate to all the cylinders during gas-engine operation. The dual-fuel engine is started by the diesel engine operation and is changed over to gas-engine operation when the load increases. This change over is done automatically with a link mechanism. Regarding the gas-supply system, the changing pressure of supply gas is controlled by a pressure control valve which is stable and most adequate for the engine. The dual-fuel engine has the following features: (1) a high compression ratio is adopted, which reduces fuel consumption and thermal efficiently; (2) if the supply of gas decreases or stops, while continuing loaded operations, it can immediately shift to diesel engine operation automatically and continue the operation; (3) ignition is done by the injection of pilot oil, thus eliminating ...

1980-01-01

485

Metallic implants and exposure to radiofrequency radiation  

International Nuclear Information System (INIS)

There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in ...

486

Measurement of swirling flow in direct injection diesel engine (Part 2). Effect of piston cavity diameter and top clearance volume  

Energy Technology Data Exchange (ETDEWEB)

Swirling flow in a direct injection diesel engine was measured by a laser doppler velocimeter. Piston cavity diameter and top clearance volume were changed as factors affecting swirling flow to study the distribution of swirling flow speed. When using the same intake port and changing the opening ratio of piston cavity, the distribution of swirling flow speed was different by the cavity during intake process but these agree just after opening intake valve and then become again different by cavity. When increasing top clearance and decreasing compression ratio, the axial symmetry of flow during commpression process increases. When changing piston cavity, and also when changing intake port, the mean swirling ratio in inside and outside areas of combustion chamber has common tendency to increase and decrease respectively. The mean swirling flow in the combustion chamber may be capable to be predicted by devising a model which can describe this tendency. 3 refs., 9 ...

1989-05-31

487

Measurement of swirling flow in direct injection diesel engine (Part 1). Effect of intake port geometry and engine speed  

Energy Technology Data Exchange (ETDEWEB)

Swirling speed in a direct injection diesel engine was measured by a laser doppler velocimeter. Intake port geometry and engine speed were changed as factors affecting the swirling flow to study the distribution of swirling flow speed. The distribution of swirling flow speed changes complicatedly owing to axial nonsymmetry during intake process but becomes simple shape of axial symmetry during compression process after closing intake valve. But if this is assumed as the rigid swirl shape, the difference due to each intake port cannot be expressed but also large error may be possible to appear close to the cylinder wall. The distribution of swirling flow speed during compression process changes similarly, nearly proportinal to engine speed. But the similarity is higher at the middle period in compression process than at the end period in compression period. Axial distribution of local swirling ratio during compression process is nearly uniform. 8 refs., 10 figs., 1 ...

1989-05-31

488

Ion exchange at TNX using the SKID unit  

Energy Technology Data Exchange (ETDEWEB)

An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination factor (DF) will be measured for a non-radioactive, simulated, ...

1993-10-21

489

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by BSC and DSO and will not be placed until ...

1990-09-10

490

Higher order time-frequency analysis as a tool for health monitoring  

Energy Technology Data Exchange (ETDEWEB)

In machine condition monitoring many fault-related vibration signals are highly non-stationary. Time-frequency representations comprise the natural signal-processing tool traditionally used for representing such non-stationary signals. The methods used in this analysis are based on the second order statistics of a signal. This paper discusses the use of higher order time frequency methods in the context of a condition monitoring application. The paper outlines the two classes of higher order representations: the L-Wigner distribution and the sliced Wigner higher order distribution. The use of higher order distributions introduces the possibility of non-oscillating cross-terms, a problem not encountered in conventional bilinear time-frequency methods. Techniques for reducing these cross-terms are presented. The paper compares the performance of bilinear and higher order time-frequency methods using synthetic data and vibration signals measured on the engine block of the passenger car ...

2003-07-01

491

HC cylinder to cylinder deviation at idling condition in a direct injection diesel engine. Chokusetsu funshashiki diesel kikan mufuka untenji no HC kitokan hendo  

Energy Technology Data Exchange (ETDEWEB)

Causes of variation of hydrocarbon (HC) concentration in cylinder to cylinder at idling condition in a direct injection diesel engine were studied. The ratio of l/d=6 gives larger HC variation in cylinder to cylinder than the l/d=2, where l means the nozzle hole length and d means the nozzle hole diameter. This is because the condition of l/d=6 can result in the large spray penetration and increase the fuel on the combustion chamber. The spray structure changes between nozzles and also changes between nozzle holes. This is not caused by the shape of nozzle hole but is affected by the pressure change near the inlet of nozzle hole when the needle valve is lifted. The change of spray structure can change the injection volume between nozzle holes. The injection volume is less for a nozzle hole where the curved angle becomes sharp to the nozzle central angle, and is more at the opposite side. When the injection volume of the nozzle hole near the chamber wall increases, ...

1992-07-01

492

GRI's Gas Appliance Technology Center: 1989 annual report, February 1989-April 1990 (Activity at Battelle)  

Science.gov (United States)

The goal of GRI's Gas Appliance Technology Center is to encourage the introduction of highly efficient, cost-effective, convenient gas appliances for residential and commercial gas users. The report covers activity at Battelle from February 1989 to April 1990 in broad support tasks, residential and commercial appliances, and residential space conditioning. Broad support tasks included the G/A/S Newsletter; the GATC InfoBase; and technology transfer, workshops, and GATC coordination. Residential appliance tasks included burner technology research, gas appliance venting, gas lighting, and plastics durability. Commercial appliance tasks included development of a commercial cooktop fuel/air mixing valve. Residential space conditioning tasks included a corrosion test method for gas appliances and vents, generic technology for condensing heat exchangers, and technology for self-powered appliances. These tasks are described briefly, with references to reports and ...

1990-12-01

493

Fast diagnosis and treatment of crack-like defect injuriousness in nuclear power plant equipment  

Energy Technology Data Exchange (ETDEWEB)

Increasingly stringent safety requirements governing the nuclear industry have made it essential to gain in-depth knowledge of the injuriousness of cracking phenomena in auxiliary and secondary nuclear power plant systems, and to devise methods of rapidly evaluating potentially injurious flaws. The Defect Injuriousness Diagnosis and Treatment Package (DIDTP) discussed in this paper was developed by Framatome, a French-based PWR builder, with this goal in mind. A general description is given of the DIDTP, which is made up of tables and nomographs illustrating the injuriousness of flaws liable to be encountered in the most severely loaded regions of plant systems. The basic principles underlying the DIDTP, together with computational methods and application procedure, are detailed. Two practical examples illustrating the use of the diagnostic system are presented, one applied to the main steam line, the other to gate valve wedges. The types of results obtained and ...

1985-01-01

494

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, loss of the GDCS pool water is prevented and ...

1990-10-29

495

Device for controlling water supply to nuclear reactor  

International Nuclear Information System (INIS)

Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator generating signals for indicating whether one or two water supply pumps are operated. A low value preferential circuit passes the lower of the values generated from the ...

496

Development of a 1200 KW/CYL low pressure dual fuel engine for LNG carriers  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant fouling of the combustion chamber is still ...

1998-12-31

497

Characterization and nanopatterning of Ni{sub 2}MnIn Heusler films  

Energy Technology Data Exchange (ETDEWEB)

The Heusler alloy Ni{sub 2}MnIn is a promising material as spin injector because of its predicted half-metallicity at the interface to InAs. We grow thin films of this Heusler alloy by thermal coevaporation of Nickel and the alloy MnIn. The alloy is grown on Si{sub 3}N{sub 4} membranes and amorphous carbon films for transmission-electron microscopy (TEM) as well as on Si and InAs. The degree of the transport spin polarization of the films grown on Si(100), InAs(100) and in-situ cleaved (110) surfaces of InAs is determined by point-contact Andreev reflection spectroscopy (PCAR). The almost perfect lattice match between InAs and Ni{sub 2}MnIn supports highly oriented growth, as we have proven by electron diffraction under grazing incidence. Lateral spin valves with Heusler electrodes are lithographically defined. In view of the temperature-sensitivity of the optical and electron-beam resists, the samples are grown at substrate temperatures of 50 C and annealed up to ...

2008-07-01

498

An analysis of PZR and related system design features for KNGR  

Energy Technology Data Exchange (ETDEWEB)

The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were higher and lower, respectively than those of UCN 3 and 4. Also, it ...

1995-12-01

499

Advanced PWR technology development -Development of advanced PWR system analysis technology-  

Energy Technology Data Exchange (ETDEWEB)

The primary scope of this study is to establish the analysis technology for the advanced reactor designed on the basis of the passive and inherent safety concepts. This study is extended to the application of these technology to the safety analysis of the passive reactor. The study was performed for the small and medium sized reactor and the large sized reactor by focusing on the development of the analysis technology for the passive components. Among the identified concepts the once-through steam generator, the natural circulation of the integral reactor, heat pipe for containment cooling, and hydraulic valve were selected as the high priority items to be developed and the related studies are being performed for these items. For the large sized passive reactor, the study plans to extend the applicability of the best estimate computer code RELAP5/MOD3 which is widely used for the safety analyses of the reactor system. The improvement and supplementation study of ...

1995-07-01

500

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both extensibility and flexibility. As a result, the complexity of the hardware is ...

2001-07-20