WorldWideScience
1

The inhibition of staphylococcus epidermidis biofilm formation by vancomycin-modified titanium alloy and implications for the treatment of periprosthetic infection  

UK PubMed Central (United Kingdom)

Peri-prosthetic infections are notoriously difficult to treat as the biomaterial implant is ideal for bacterial adhesion and biofilm formation, resulting in decreased antibiotic sensitivity....Full Text Available

2008-12-01

2

Early Post-operative Periprosthetic Femur Fracture in the Presence of a Non-cemented Tapered Wedge Femoral Stem  

UK PubMed Central (United Kingdom)

Non-cemented femoral fixation in hip arthroplasty has become the standard of practice in the USA. However, recent literature has brought attention to an increasing incidence of periprosthetic femur...Full Text Available

2010-09-01

3

Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event  

International Nuclear Information System (INIS)

In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle heat transfer model, ...

2001-10-01

4

Grafoil applications on-plant  

International Nuclear Information System (INIS)

Presented in this report are the quantitative and qualitative aspects of the more than 5,800 applications of Grafoil on-plant. The subject all-graphite product was originally made by the Union Carbide Corporation. Its utilization in the forms of valve packing, gasketing and sealant tapes for leak repair and prevention on-plant since March 1970 is marked with typical zero-leak results. For all practical purposes, the successful results with Grafoil implementation indicate an unqualified control of leakage problems that began in 1967 with the V-11 and V-12 valves in the primary system of N Reactor. Meaningfully, the accruals of savings with existing and future applications shall continue to be incalculable in personnel exposure, maintenance, and capital. Inherent in the savings are the devised methodology and innovative developments coordinately employed in resolving the leak repair problems.

5

Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application includes heat transfer ...

2001-03-01

6

Friction in ultra-thin conjunction of valve seals of pressurised metered dose inhalers  

British Library Electronic Table of Contents (United Kingdom)

In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...

2010-01-01

7

TECHNICAL REPORT - NASA Technical Reports Server  

Science.gov (United States)

VORTEX VALVE FLOW CHARACTERISTICS. 49. VENTED VORTEX VALVE. 50. VORTEX DIVERTER VALVE- ... 46 AND VORTEX MIXING VALVE FLOW CHARACTERISTICS ...

8

Heart Valve Replacement  

Medline Plus

X-Plain Heart Valve Replacement Reference Summary Introduction Sometimes people have serious problems with their heart valves. A heart valve repair or ...

9

Freeze protection valve for solar heaters  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway ...

1987-07-21

10

CHLOROPICRIN LEAKAGE TEST OF THE M17 PROTECTIVE ...  

Science.gov (United States)

... CHLOROPICRIN LEAKAGE TEST Of THE M17 PPRDOtCTIVE MASK EQUIPPED WITH DRINKING AND RESUSCITATION DEVICIS WORN BY ...

1965-10-01

11

Wear particles, periprosthetic osteolysis and the immune system  

British Library Electronic Table of Contents (United Kingdom)

The immune system modulates many key biological processes in humans. However, the exact role of the immune system in particle-associated periprosthetic osteolysis is controversial. Human tissue retrieval studies, in vivo and in vitro experiments suggest that the immune response to polymer particles is non-specific and macrophage-mediated. Lymphocytes may modulate this response. However direct lymphocyte activation by polymer particle-protein complexes seems unlikely. However, metallic byproducts may complex with serum proteins and lead to a Type IV, lymphocyte-mediated immune reaction. In predisposed individuals, this reaction may rarely lead to persistent painful joint effusions, necessitating debridement and excision of the bearing surfaces of the prosthesis. In these patients, retrieved...

2007-01-01

12

RESEARCH STUDY OF THE VORTEX VALVE FOR - NASA Technical Reports Server  

Science.gov (United States)

Vortex Valve Flow Characteristics. Basic Circuit Schematic. System Test Installation. Flight-Weight Design of SITVC System. Staged Vortex Valve SITVC ...

13

//s /~7 - NASA CR-  

Science.gov (United States)

Valve Flow Characteristics. 3-68. 3-40. Valve Operating Current Vs. Temperature ...... VALVE FLOW CHARACTERISTICS. Acceptance Test 4/29/74. SINs 002 & 004 ...

14

A study on modelling of a butterfly-type control valve by a pneumatic actuator  

Energy Technology Data Exchange (ETDEWEB)

This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.

2009-07-01

15

Alopecia associated with unexpected leakage from electron cone  

Energy Technology Data Exchange (ETDEWEB)

Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

1989-06-01

16

In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves  

DEFF Research Database (Denmark)

BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native ...

2010-01-01

18

PROSPECTS AND CHALLENGES IN THE  

Wastenet

Country-led, national-based (programmatic) approach to avoid in-country in country leakage BUT also accepts

19

A case of noble gas leakage searching and analysis in Daya Bay NPP  

International Nuclear Information System (INIS)

The author reports briefly a noble gas leakage searching process in which a person was contaminated in Daya Bay NPP, the radionuclide causing contamination was ascertained as the daughter product of "8"8Kr, the "8"8Rb; By taking air contamination sampling and measuring the "8"8Rb concentration in the room, the leakage source was predetermined and the leakage rate of primary coolant was estimated

1999-09-01

20

Helium/solid powder O-ring leakage correlation experiments using a radiotracer  

Energy Technology Data Exchange (ETDEWEB)

UO/sub 2/ definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table.

1984-01-01

21

Computed Tomography of the complications of prosthetic surgery of the abdominal aorta  

International Nuclear Information System (INIS)

Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...

1997-01-01

22

Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve  

UK PubMed Central (United Kingdom)

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available

2010-06-28

23

Optimization of Valve Disc Using Orthogonal Array and Kriging Model  

Science.gov (United States)

A butterfly valve is a type of flow control device, typically used to regulate a fluid flowing. Currently, FEA is often used to predict the safety in the design of valve disc. Also, the study about the affection of butterfly valve's disc to the valve flow characteristics by using CFD has been done by many researchers. Along with the development of computer technique, design and analysis of computer experiments has becoming more and more important in engineering design and optimization. Hereinto Kriging model is one popular analysis approach for the purpose of creating a cheap ``meta-model'' as a surrogate to a computationally expensive simulation model. In this paper, the numerical analysis considered the strength, pressure loss coefficient and weight of valve disc simultaneously is investigated to improve the shape of a traditional butterfly valve disc. ...

2008-10-01

24

Large scale steam valve test: Performance testing of large butterfly valves and full scale high flowrate steam testing  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned ...

1995-05-01

25

Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants  

International Nuclear Information System (INIS)

This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV ...

1992-07-01

26

Technical Lio - NASA Technical Reports Server  

Science.gov (United States)

Mod IE did not affect the valve flow characteristics. C. BIPROPELLANT -VALVE EVALUATION. 1. Ball and Shaft Seal Evaluation ...

27

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability  

CERN Document Server

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability

1989-01-01

28

Development of linear flow rate control system for eccentric butter-fly valve  

Energy Technology Data Exchange (ETDEWEB)

Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)

1999-12-01

30

Newly developed control and stop valves  

International Nuclear Information System (INIS)

... bwr type reactors closures fluidic control devices operation performance pwr

31

Electromagnetic fluid valve  

International Nuclear Information System (INIS)

... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic

33

Thermal-hydraulic analysis following a safety flapper valve's fault for a pool-type research reactor  

International Nuclear Information System (INIS)

One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)

34

Recycling flow control device for a nuclear reactor  

International Nuclear Information System (INIS)

Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and ...

35

An experimental study on stable flow control for multi-stage expansion device  

Energy Technology Data Exchange (ETDEWEB)

An Experimental study was performed to investigate flow characteristic of multi-stage expansion valve applied with inverter heat pump. Multi-stage expansion consists of parallel valve which is controlled on/off type of solenoid valve. Expansion valve open one solenoid the other closed in low frequency region and open two solenoid valve in high frequency region. In rated frequency region always open one solenoid valve and control period and on-off time ratio for the other solenoid valve. Flow characteristics of a orifice expansion was measured as a function of orifice diameter and operating conditions. As a results multi-stage expansion device can control a stable flow with period and on-off time ratio. (author). 4 refs., 7 figs., 1 tab.

1998-04-01

36

Distinguishing between parenchymal and anastomotic leakage at duct-to-mucosa pancreatic reconstruction in pancreaticoduodenectomy  

UK PubMed Central (United Kingdom)

AIM: To distinguish anastomotic from parenchymal leakage at duct-to-mucosa reconstruction of the pancreatic remnant.METHODS: We reviewed the charts of 68 pancreaticod-uodenectomies performed...Full Text Available

2008-11-21

37

Changes in the surface fine structure of ependyma of the rat third ventricle following operative leakage of cerebrospinal fluid.  

UK PubMed Central (United Kingdom)

The role of the ventricular ependyma in the elaboration of cerebrospinal fluid under resting conditions is well documented. In an attempt to elucidate its response to cerebrospinal fluid leakage, male...Full Text Available

1985-01-01

38

Temperature Dependences of Leakage Currents of ZnO Varistors Doped with Rare-Earth Oxides  

British Library Electronic Table of Contents (United Kingdom)

Rare-earth oxides are doped into ZnO varistors as grain growth inhibitors for increasing the varistors' voltage gradients. However, their leakage currents become large and their nonlinear coefficients decrease at the same time. The reasonable explanation for such a phenomenon has not yet been available. In this paper, the temperature dependences of varistor samples' leakage currents are investigated, which reveal that the increased leakage currents of ZnO varistors with Y2O3 doping are mainly due to the bypass paths through the intergranular materials at grain corners.

2010-01-01

39

Prognostic implications of pulmonary hypertension in patients with severe aortic stenosis  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...

2011-01-01

40

Linearization of Valve Flow Characteristics for Steam Turbine Control  

Energy Technology Data Exchange (ETDEWEB)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)

2009-10-15

41

Linearization of Valve Flow Characteristics for Steam Turbine Control  

International Nuclear Information System (INIS)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)

2009-10-01

42

Nomographs for the rapid prediction of salt quality and influent water quality impacts on hardness leakage in steamflood water  

Energy Technology Data Exchange (ETDEWEB)

Counter-current regeneration of 2-stage sodium zeolite softeners has been employed in reducing hardness leakage level of steamflooding water to less than 1 ppm when raw water contains as much as 5,000 ppm of the total dissolved solids. Hardness leakage is caused by sodium displacement of calcium and magnesium from the bottom of the exchanger bed. This study presents nomographs providing for rapid calculations to be made, for which a convenient operational mode does not already exist. The nomographs relate the hardness leakage as a function of salt quality and influent water quality and present solutions for predicting the leakage level, salt quality requirement or the treatability of raw water required for steamflooding projects.

1982-08-01

43

Oil pipeline valve automation for spill reduction  

Energy Technology Data Exchange (ETDEWEB)

Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application ...

2003-07-01

44

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic ...

2009-04-15

45

Challenges in commissioning and operation of 'first-of -its- kind' liquid zone control system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level measurement of one of the ZCCs (ZCC - 1) was found erratic and inconsistent. Methodologies were developed to identify the problem and investigations revealed ...

2006-11-13

46

Total prosthetic replacement of atrioventricular valves in the dog  

UK PubMed Central (United Kingdom)

The metal parts of cardiac valve prostheses cause reactions in the surrounding tissues of the heart. In some dogs rather abnormal reactions were found, and were attributed to corrosion of the stainless...Full Text Available

1972-01-01

47

Selecting the right pumps and valves for flue gas desulfurization  

Science.gov (United States)

Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.

2006-07-15

48

Percutaneous mitral valve repair: the beginning of the end or the end of the beginning?  

UK PubMed Central (United Kingdom)

The new percutaneous mitral valve repair techniques are at an early stage. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary...Full Text Available

49

Latent Tricuspid Valve Rupture after Motor Vehicle Accident and Routine Echocardiography in All Chest-Wall Traumas  

UK PubMed Central (United Kingdom)

Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available

2009-01-01

50

Heterotopic transcatheter tricuspid valve implantation: first-in-man application of a novel approach to tricuspid regurgitation  

UK PubMed Central (United Kingdom)

AimsTranscatheter treatment of heart valve disease is well established today. However, for the treatment of tricuspid regurgitation (TR), no effective catheter-based approach is...Full Text Available

2011-05-01

51

Cavitation guide for control valves  

Energy Technology Data Exchange (ETDEWEB)

This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of ...

1993-04-01

52

Gunsof - NASA  

Science.gov (United States)

end of the barrel. The petal valve and ring seal are inserted behind it, and the gun barrel assembly and HP section are clamped together with hydraulic collars. ...

53

Evaluation of the fluid force in main feed water control valve for APWRs  

International Nuclear Information System (INIS)

... 2432 v. 43(1) SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

2006-01-01

54

Active Shimmy Control System  

Science.gov (United States)

... Both effects are undoubtedly caused by the ahaping of the spool valve flow characteristics The linear region of response corresponds to ...

1975-12-01

55

On the Improved Plasma Confinement in Toroidal Systems. Measuring of the Plasma Density Inhomogeneities Near the Gas Valve  

International Nuclear Information System (INIS)

Comparison of plasma density increase was carried out in outer and inner channels of the interferometer in T-11M tokamak. There were two cases of gas puffing: by outer valve or upper one. Amplitude of difference of the plasma density increase consisted of 9% near the outer valve. Perturbation of the electric potential e?1/Te can have similar value. This perturbation can lead to appearance of the additional losses.

2006-01-01

56

Effects on fatigue life of gate valves due to higher torque switch settings during operability testing  

Energy Technology Data Exchange (ETDEWEB)

Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond the scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and ...

1995-12-01

57

Dynamic performance testing of control valves  

International Nuclear Information System (INIS)

Response of control valves plays an important role in the dynamics of the flow system as a whole. Knowledge of its transfer function would facilitate analysis of the behaviour of the system. This paper presents the application of Levy's complex curve fitting method for determination of the transfer function of control valves used in Liquid Zone Control System of 540 MWe PHWR. (author)

2005-02-01

58

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

59

Neutron leakage benchmarks for water moderators  

Energy Technology Data Exchange (ETDEWEB)

Fission reaction rates for four nuclides were measured in the leakage spectrum outside spherical water moderators of various radii surrounding a {sup 252}Cf neutron source. Using the MCNP transport code, matching calculations were made with highly detailed modeling of the measurement apparatus. The calculations predicted significantly higher leakage of neutrons in the epicadmium energy range than was found in the measurements. A discrepancy of the same sign but weaker magnitude was found for thermal neutrons. These discrepancies may be relevant to problems with criticality calculations in special cases.

1994-12-31

60

Wi!''lrm!m REPORT - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Moreover, when the gun barreL is swung through an an~1e ran~e, ... the ta~jerin the gun barrel and 'theair leakage throlughthe ...

61

Process for repairing a cryogenic heat exchanger  

International Nuclear Information System (INIS)

The patent describes a method for repairing leakage-causing cracks and fissures in a cryogenic heat exchanger. It comprises: reducing the interior pressure of the heat exchanger to a level which does not exceed the external pressure upon the hear exchanger while maintaining the temperature of the heat exchanger at a low level relative to the ambient external temperature; applying a curable liquid filler composition to the surface of the heat exchanger proximal the leakage site for seepage into the cracks and fissures located at the leakage. The composition upon a relatively short period of cure at low temperature forming a solid material which fills the cracks and fissures; curing the filler composition; and, applying a sealant composition to the surface of the heat exchanger at the filled leakage site. The sealant composition having long-term sealing performance under cyrogenic conditions.

1987-10-13

62

Containment integrated leakage rate test (ILRT) of Indian PHWR  

International Nuclear Information System (INIS)

Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian Pressurized Heavy Water Reactor (PHWR) ...

2005-12-01

63

Linearization of Valve Flow Characteristics for Steam Turbine Control  

Energy Technology Data Exchange (ETDEWEB)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.

2009-05-15

64

Linearization of Valve Flow Characteristics for Steam Turbine Control  

International Nuclear Information System (INIS)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.

2009-05-01

65

Dynamic modelling of check valves in shipping terminals; Modelagem dinamica de valvulas de retencao em terminais maritimos  

Energy Technology Data Exchange (ETDEWEB)

As usual a shipping terminal contains a header and its diameter is smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves without dynamic modeling may introduce some error in the maximum pressure results without a dynamic model approach. The current paper uses commercial pipeline simulation software to model the dynamic behavior of the check valves. It was studied the header diameter influence and how the check valve model type may change the maximum pressure in the pipeline. It was proved that even a pipeline that works with low pressure and small elevation drop needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)

2005-07-01

66

Experimental parametric equation for the prediction of valve coefficient (C_v) for choke valve trims  

International Nuclear Information System (INIS)

The calculation of nominal choke valve size determines the effective capacity for an oil and gas production system. The degree of restriction for the controlling area in the valve is a function of the surrounding geometry. In an orifice plate this is known as the 'velocity of approach' and can be used to determine the meter coefficient (C_m). This paper presents a technique for choke valves, based on the meter velocity of approach parameter, which can be used to predict the Valve Coefficient (C_v) for new trim designs. The prediction method uses a data trend based on a number of flow tests conducted on various trim characteristics. The resultant parametric equation is used to predict the C_v of a new trim geometry. The method relies on experimental data determined per IEC 60534-2-3, with calculations per IEC 60534-2-1. This paper further investigates the effect of varying upstream geometry on C_v for a ...

67

Management considerations of the large primary-to-secondary leakage accidents  

Energy Technology Data Exchange (ETDEWEB)

The management procedure of a large PRISE (Primary-to-Secondary) leakage accident at Loviisa nuclear power plant taking into account the plant modifications which are expected to be realized during 1995-96 is described. The management procedure has been validated by performing thermal hydraulic analyses with the computer code RELAP5/MOD3 and the results from these analyses are also shortly discussed. (4 refs., 6 figs., 1 tab.).

1993-12-31

68

Assessment of pipeline integrity and associated hazards  

Energy Technology Data Exchange (ETDEWEB)

This paper outlines aspects of the procedures adopted within Nuclear Electric plc for the assessment of Leak before Break arguments and the consequences arising from leakage and/or pipe failure. Only new aspects are considered such as creep, leakage, temperature and over pressure assessments and pipe whip. 7 refs.

1995-12-31

69

Effect of Hydrogen on leakage current characteristics of (Pb, La) (Zr, Ti)O{sub 3} (PLZT) thin film capacitors with Pt or Ir-based top electrodes  

Energy Technology Data Exchange (ETDEWEB)

The leakage current behaviors of PLZT capacitors with top electrodes of Pt, Ir, and IrO{sub 2} are investigated before and after hydrogen forming gas anneal. The P-E hysteresis and fatigue properties of Pt/PLZT/Pt capacitors are almost recovered after recovery anneal in O{sub 2} ambient. The leakage current mechanisms of PLZT capacitors with Pt and IrO{sub 2} top electrodes are consistent with space-charge influenced injection model showing the strong time dependence irrespective of annealing conditions. On the other hand, the leakage current behavior of Ir/PLZT/Pt capacitor shows steady state independent of time because IrPb, conducting phase, formed at interface between Ir top and PLZT is a high conduction path. Teh leakage current mechanism of Ir/PLZT/Pt capacitor is consistent with Schottky barrier model. (author). 15 refs., 6 figs.

2001-02-01

70

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular ...

71

Development of new three way valve using vacuum for liquid transfer  

International Nuclear Information System (INIS)

The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)

2008-07-01

72

Training aids: the motor operator valve trainer  

International Nuclear Information System (INIS)

The spectrum of training aids used in the nuclear industry runs the gamut from the very basic (i.e., valve training aids - gate, globe, check) to the highly complex (i.e., nuclear full scope simulator). Designing and purchasing the best training aids take much time, detailed investigation, and good understanding of plant operations. The training aid that has given the New York Power Authority the best results has been the motor operator valve (MOV) trainer. Some of the items that make the MOV trainer a good choice are: (1) large number of MOVs in the plant, (2) importance of MOVs to safe plant operation, (3) detailed MOV procedures used by the plant, (4) history of MOV problems, and (5) ability to demonstrate important concepts and operation - hammer blow effect, torque and limit switch adjustment and functions, and actual sequence of operation of the limitorque valve operator.

1987-06-07

73

The National Shipbuilding Research Program Task S-20: A ...  

Science.gov (United States)

... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...

1979-05-01

74

Flow mapping for assessment of native and repaired valves  

International Nuclear Information System (INIS)

Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.

75

Flow characteristics and dynamics of swing check valves in compressible flow applications (Part-1)  

Energy Technology Data Exchange (ETDEWEB)

In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle vs. mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements in compressible flows. This paper presents results of steady compressible flow testing of an NPS 4 swing type check valve in air. Mean flow velocities vs. ...

1996-12-01

76

Effects of compressibility on flow characteristics and dynamics of swing check valves. Part 1  

Energy Technology Data Exchange (ETDEWEB)

In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle versus mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements involving fluids of relatively higher compressibility. This paper presents results of steady flow testing of an NPS 4 swing-type check valve in air. Mean ...

1997-05-01

77

Control rod drives  

International Nuclear Information System (INIS)

Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the ...

78

An analysis and evaluation of differential pressure calculation of motor operated valve using system flow model  

Energy Technology Data Exchange (ETDEWEB)

As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.

1999-11-01

80

3 - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011... properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. ...

81

Percolation-theory and fuzzy rule-based probability estimation of fault leakage at geologic carbon sequestration sites  

Energy Technology Data Exchange (ETDEWEB)

Leakage of CO{sub 2} and displaced brine from geologic carbon sequestration (GCS) sites into potable groundwater or to the near-surface environment is a primary concern for safety and effectiveness of GCS. The focus of this study is on the estimation of the probability of CO{sub 2} leakage along conduits such as faults and fractures. This probability is controlled by (1) the probability that the CO{sub 2} plume encounters a conductive fault that could serve as a conduit for CO{sub 2} to leak through the sealing formation, and (2) the probability that the conductive fault(s) intersected by the CO{sub 2} plume are connected to other conductive faults in such a way that a connected flow path is formed to allow CO{sub 2} to leak to environmental resources that may be impacted by leakage. This work is designed to fit into the certification framework for geological CO{sub 2} storage, which represents vulnerable resources such as ...

2009-05-01

82

Influence of the strain-relaxation induced defect creation on the leakage current of embedded Si{sub 1-x}Ge{sub x} source/drain junctions  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to evaluate the role of the strain-relaxation processes on the leakage current of embedded SiGe S/D junctions. Current-voltage (I-V) and capacitance-voltage (C-V) characteristics were measured to further investigate the relaxation degree of embedded SiGe S/D junctions in the regime where partial relaxation by misfits dislocations is assumed, yielding a reduction of the leakage current density. Further, the impact of the ion implantation-related defects on the electrical performance is discussed. The analysis is complemented with structural characterization based on High Resolution Transmission Electron Microscopy (HRTEM) and Nomarski microscopy. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2009-08-15

83

Use of endobronchial one-way valves reveals questions on etiology of spontaneous pneumothorax: report of three cases  

UK PubMed Central (United Kingdom)

Spontaneous pneumothoraces are believed to arise when air from the supplying airway exit via a ruptured visceral pleural bleb into the pleural cavity. Endobronchial one-way valves (EBVs) allow air exit...Full Text Available

84

Studies of neural networks for engine control: application to the electromechanical valves engine; Etudes des reseaux de neurones pour le controle moteur: application a soupapes electromecaniques  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)

1997-12-31

85

Multilayer structures with giant magnetoresistance  

International Nuclear Information System (INIS)

The phenomenological description of the giant magnetoresistance effect as well as discussion of the requirements which must be fulfilled in giant magnetoresistance thin film structures are given in the first part of our review. In the second part the magnetization reversal and giant magnetoresistance effect of antiferromagnetically coupled multilayers, spin Valve and pseudo-spin valve thin film structures are explained. For these structures we also discuss the influence of the structure defects such as surface roughness and pinholes on the giant magnetoresistance effect. (author)

2001-09-23

86

Hydraulic device for control rod drive mechanisms  

International Nuclear Information System (INIS)

Purpose: To improve the reliability of control rod drive mechanisms for use in BWR type reactors by preventing erroneous insertion of control rods caused by the increase in the coolant pressure. Constitution: A pressure-releaf valve mechanism is provided which opens its valve when a detected difference between the pressure of the coolants flowing through coolant pipeways and the reactor pressure exceeds a predetermined pressure difference. If the coolant pressure increases abnormally, coolants in the coolant pipeway are released to lower the pressure. (Aizawa, K.).

1981-07-31

87

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, ...

88

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography  

UK PubMed Central (United Kingdom)

AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available

2008-10-01

89

The Use of Self-Expanding Plastic Stents in the Management of Oesophageal Leaks and Spontaneous Oesophageal Perforations  

UK PubMed Central (United Kingdom)

Leakage after oesophageal anastomosis or perforation remains a challenge for the surgeon. Traditional management has been operative repair or intensive conservative management. Both treatments are...Full Text Available

2011-01-01

90

Effects of Sildenafil and Tadalafil on Intraocular Pressure in Sheep: Implications for Aqueous Humor Dynamics  

UK PubMed Central (United Kingdom)

Purpose.To determine the effects of vasodilators on intraocular pressure (IOP) and the protein content of sheep aqueous humor (AH), because the vasodilators may increase fluid leakage...Full Text Available

2010-06-01

91

A Case of Myelopathy after Intrathecal Injection of Fluorescein  

UK PubMed Central (United Kingdom)

We present a case with seizure, confusion, hypesthesia and paraplegia after intrathecal injection of fluorescein. A 41-year-old man was admitted to our institution for the management of the CSF leakage....Full Text Available

2007-12-01

92

Use of explosive quick depressurization valves in the SBWR project. Dynamic loads induced by their operation  

International Nuclear Information System (INIS)

In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...

93

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve ...

1995-09-01

94

New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems  

International Nuclear Information System (INIS)

Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

95

Influence of the humidity on leakage current under accelerated aging of polymer insulating materials  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.

1996-12-31

96

Optimising the flow characteristic of a coke-oven flue-gas valve by means of Computational Fluid Dynamics (CFD); Stroemungsoptimierung eines Abgasventils von Koksoefen durch Computational Fluid Dynamics (CFD)  

Energy Technology Data Exchange (ETDEWEB)

In coke-oven operations flue-gas valves are used to switch the regenerator function from rich gas firing to lean gas firing. Compared with the simple geometry of the other parts of the flow path, which comprise flues and regenerators, the narrow and winding passages of the flue-gas valves give rise to relatively high losses in pressure. Without the construction of high (and therefore expensive) chimneys, this means that operating problems may well arise due the inadequate suction capacity. The project focused on the theoretical and experimental analysis of a coke-oven flue-gas valve. The primary aim was to reduce the pressure drop through the valve without modifying its external geomerty. The internal flow characteristics created by different valve geometries under a variety of operating conditions were simulated using the commercial CFD code Fluent/UNS, which provided velocity and ...

1999-06-01

97

Evaluation of the flow forces on a direct (single stage) proportional valve by means of a computational fluid dynamic analysis  

International Nuclear Information System (INIS)

The aim of this paper is to investigate the fluid dynamic behaviour of a commercial hydraulic proportional valve in order to evaluate and justify its global performances and, in particular, to analyze the effects of some additional design features on the reduction of the force required to maintain the valve open. The proposed analysis has been performed by applying the commercial computational fluid dynamics (CFD) code, Fluent, to the solution of the three dimensional turbulent flow field through a circumferential sector of the entire valve for different spool strokes. The reliability of the employed modelization is demonstrated by the comparison between the computed flow rate curve and the corresponding experimental data provided by the manufacturer. With regard to the metering edge design, it is shown that the cylindrical hole provided on the top of the hemi-spherical notch to improve metering at small ...

2007-03-01

98

Surge pressure behavior in reduced diameter segments of shipping terminals; Comportamento de pulsos de pressao em trechos de diametro reduzido de dutos de terminais maritimos  

Energy Technology Data Exchange (ETDEWEB)

In a shipping terminal, the pipeline in the pier usually has a diameter smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves placed in the pier may introduce some error in the maximum pressure when it was modeled in a conventional fashion. The dynamic check valve model had been added to a commercial pipeline simulation software and the results was compared with a similar model using the method of characteristics. Considering a real state shipping terminal case, it was proved even a pipeline that works with low pressure and smooth elevation profile needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)

2004-07-01

99

Modeling of a self-excited pulse combustor and stability analysis  

British Library Electronic Table of Contents (United Kingdom)

The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...

2011-01-01

100

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to the reference level and the possibility ...

1981-11-18

101

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).

1981-11-12

102

Relationships of valve histology and mitochondrial and myofibril volume densities to hypertrophy of copper-deficient rat hearts  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four male weanling rats were fed either copper-adequate or -deficient diets until 9 or 11 weeks of age. Deficient rat hearts had increased mitochondria: myofibril compared to adequate rats. Eleven week old deficient rat hearts had decreased mitochondria: myofibril as the hearts increased in weight, but the larger hearts had greater myofibril volume densities. Cardiac mitochondria of deficient rats appeared vacuolated with fragmented cristae and translucent matrix. Valves from copper deficient rats appeared to have less connective tissue and were fragmented in areas. For deficient rats, heart:body weights of 9 wk old rats were negatively correlated with bicuspid valve pathology scores, whereas tricuspid valve scores from 11 wk old rats were negatively correlated with myofibril volume densities. These data suggest that the enlargement of the copper-deficient rat heart is due to: larger (1) mitochondria and (2) ...

1991-03-15

103

Primary coolant depressurization facility  

Energy Technology Data Exchange (ETDEWEB)

In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible ...

1992-10-14

104

Platelet thrombosis in cardiac-valve prostheses  

International Nuclear Information System (INIS)

The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue ...

1989-06-08

105

Malfunction of a Heimlich flutter valve causing tension pneumothorax: case report of a rare complication  

UK PubMed Central (United Kingdom)

BackgroundThoracic injuries play an important role in major trauma patients due to their high incidence and critical relevance. A serious consequence of thoracic trauma is pneumothorax,...Full Text Available

106

Lower Urinary Obstruction in Infancy  

UK PubMed Central (United Kingdom)

This paper reviews 165 cases of lower urinary obstruction in infancy. The commonest lesions were posterior urethral valves (91) and ectopic ureterocele (34), stenosis or atresia of the urethra (8),...Full Text Available

1972-04-01

107

Hydraulic system for driving control rods  

International Nuclear Information System (INIS)

Purpose: To enable safety reactor shut down upon occurrence of an abnormal excess pressure in a hydraulic control unit. Constitution: The actuation pressure for a pressure switch that generates a scram signal is set lower than the release pressure set to a pressure release valve. Thus, if the pressure of nitrogen gas in a nitrogen container increases such as upon exposure of the hydraulic control unit to a high temperature, the pressure switch is actuated at first to generate the scram signal and a scram valve is opened to supply water at high pressure to control rod drives under the driving force of the nitrogen gas at high pressure to rapidly insert the control element into the reactor and shut down it. If the pressure of the nitrogen gas still increases after the scram, the pressure release valve is opened to release the nitrogen gas at high temperature to the atmosphere. Since the scram is attained before the actuation ...

1980-11-07

108

EDF's experience in the operation of pump-storage plants  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.

1992-01-01

109

Double-Valve Libman-Sacks Endocarditis Causing Ventricular Fibrillation Cardiac Arrest  

UK PubMed Central (United Kingdom)

Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available

2011-01-01

110

Development of new decompression brake for large diesel engine. Part 2. Evaluation on durability and reliability; Ogata diesel engine yo shingata asshukuatsu kaihoshiki brake no kaihatsu. 2. Taikyu shinraisei no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This report deals with the establishment of durability and reliability for the new type decompression brake system for large diesel engines. By testing engines on the bench, it has been found that the cylinder pressure, with the cylinder at the compression stroke upper dead center, imposed on the exhaust valve bevel section during brake operation constitutes the maximum load on the valve train system, that the cylinder pressure, with the cylinder at the compression stroke upper dead center, rises in proportion to a rise in the engine rpm, and that the load on the valve train system is at its maximum when the exhaust valve opens by brake operation. By examining the conditions whereunder a real vehicle was allowed to run, it has been found that the brake is applied approximately four times more often when the vehicle runs in a city area than on an expressway and that when running on the expressway the ...

1995-04-20

111

Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT): a non-surgical method of lung volume reduction  

UK PubMed Central (United Kingdom)

BackgroundLung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently,...Full Text Available

112

Decrease in dust content and removal of sludge during drilling ascending shafts in coal  

Energy Technology Data Exchange (ETDEWEB)

Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.

1983-01-01

113

Chylopericardium after cardiac surgery can be treated successfully by oral dietary manipulation: a case report  

UK PubMed Central (United Kingdom)

We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available

114

40 CFR 63.322 - Standards.  

Science.gov (United States)

...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...

2009-07-01

115

Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods  

Energy Technology Data Exchange (ETDEWEB)

Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.

1996-12-31

116

Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A  

Energy Technology Data Exchange (ETDEWEB)

Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

1986-10-01

117

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

118

Freeze protection valve and system  

Energy Technology Data Exchange (ETDEWEB)

The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.

1985-12-10

119

Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model.  

Science.gov (United States)

Percutaneous osseointegrated prostheses are being investigated as an alternative strategy to attach prosthetic limbs to patients. Although the use of these implants has shown to be promising in clinical trials, the ability to maintain a skin seal around an osseointegrated implant interface is a major challenge to prevent superficial and deep periprosthetic infections. The specific aim of this study was to establish a translational load-bearing ovine model to assess postoperative limb compensation and gait symmetry following a percutaneous osseointegrated implant. We tested the following hypotheses: (1) the animals would return to pre-amputation limb loads within 12-months; (2) the animals would return to a symmetrical gait pattern (stride length and time in stance) within 12-months. The results demonstrated that one month following surgery, the sheep loaded their amputated limb to a mean value of nearly 80% of their pre-amputation loading condition; by 12-months, ...

2011-09-13

120

Sodium leak detector  

International Nuclear Information System (INIS)

Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset value of the liquid level within the ...

121

Seal Monitoring System for an Explosive Containment Vessel  

Energy Technology Data Exchange (ETDEWEB)

Researchers at Lawrence Livermore National Laboratory are developing high-performance explosive firing vessels to contain (one time) explosive detonations that contain toxic metals and hazardous gases. The filament-wound polymer composite vessels are designed to contain up to 80 lb (TNT equivalent) explosive in a 2-meter sphere without leakage. So far, two half-scale (1-meter diameter) vessels have been tested; one up to 150% of the design explosive limit. Peak dynamic pressures in excess of 280 MPa (40 Ksi) in the vessel were calculated and measured. Results indicated that there was a small amount of gas and particle leakage past the first two of the seven o-ring seals. However, the remaining five seals prevented any transient leakage of the toxic gases and particulates out of the vessel. These results were later confirmed by visual inspection and particulate analysis of swipes taken from the sealing surfaces.

2004-06-28

122

Water-seal vacuum pumps as compact units for deaeration of steam turbine condensers in conventional and nuclear plants  

International Nuclear Information System (INIS)

On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).

123

Emissions and efficiency from production cooktop burners firing natural gas  

Energy Technology Data Exchange (ETDEWEB)

Investigations were conducted on the range of emission rates of NO, NO[sub 2], CO and hydrocarbons, and the thermal efficiencies produced by each burner on three production cookers, supplied by different Australian manufacturers. It was found that the emissions and efficiencies were markedly affected by (1) the thermal input, both with and without a load on the burner, and (2) the load-height to flame-length ratio, with a load on the burner. The effect of hydrocarbon leakage into the secondary/dilution air was investigated, to explain the observed correlation of hydrocarbon emission rate with dilution air flow. The hydrocarbons were found to arise from two sources: -leakage from the stabilisation ports at the base of the burner, which was found to be significant at the higher thermal input; -incomplete combustion of the fuel in the premix, which was the dominant source of hydrocarbons emissions at the lower thermal input. (author)

1994-12-01

124

Application of hydro-geochemical simulator to the issues on geological environment  

International Nuclear Information System (INIS)

Recently, it has become clear that the chemical circumstances under which long-term geological evolution occurs must be properly evaluated in order to develop effective remediation programs for contaminated soil, landfills, radioactive waste repositories, and carbon dioxide capture and storage. The issue of acidic leakage from excavated rock stuck was assessed using a hydro-geochemical simulator, TOUGHREACT. We concluded that in order to properly investigate the phenomenon of acidic leakage from excavated pyrite-containing rock stuck, it is important to obtain accurate information about the following factors: intensity of rainfall, unsaturated flow properties of the excavated rock stuck, specific surfaces for oxidation reaction of pyrite, the species and the quantity of other minerals contained in the rock, and secondary minerals produced. (author)

125

A finite element study of gamma ray transport  

Energy Technology Data Exchange (ETDEWEB)

A complete code based on the finite element method (FEM) is used to study the attenuation of gamma rays, of source energy 9 MeV, in simple homogeneous lead and water systems. The results are compared, in tables and graphs, with those produced by a Monte Carlo method of solution. In the comparison, particular attention is paid to the annihilation gamma rays generated by the pair production process, to energy deposition, and to the leakage spectra. A model, multilayer, slab shield, having a fission neutron source impinging on the left-hand face, is also solved by the FEM code, using data from a coupled neutron/gamma ray cross section library. The resulting neutron and gamma ray flux distributions, and the leakage spectra, are shown graphically. (author).

1990-01-01

126

Second international seminar of horizontal steam generator modelling  

Energy Technology Data Exchange (ETDEWEB)

The Second International Seminar on Horizontal Steam Generator Modelling was arranged to continue the international cooperation that was started during the first seminar in March 1991. The main topics of the seminar were: (1) further experimental results on horizontal steam generator behaviour, (2) resent developments in modelling, (3) results on analyses and studies on primary-to-secondary side leakages, and (4) results of the common exercise calculations.

1993-12-31

127

Oil cable pumping plant. Pumpestasjon  

Energy Technology Data Exchange (ETDEWEB)

The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.

1988-12-27

128

Mobile leakage detection with absorbed tracer without supply disconnection; Mobile Lecksuche mit geloesten Tracern ohne Versorgungsunterbrechung  

Energy Technology Data Exchange (ETDEWEB)

For location of leakage at district heating pipelines several techniques are available today. If there is no wire bound lead monitoring system installed, the DH company has to apply mobile methods for detection and location and if possible characterization of leakage. Most mobile methods available today are restricted in application and often they cause supply disconnections, especially the location of very small leaks is difficult. The Institute for Environmental, Safety and Energy Technology (UMSICHT) has tested a new developed method that can be executed by own employees of DH companies that can be realised parallel to normal supply mode, and that is able to locate and characterize even very small leakages. (orig.) [Deutsch] Zur Lecksuche an Fernwaermeleitungen stehen verschiedene Techniken zur Verfuegung. Wurde beim Bau der Fernwaermetrasse kein drahtgebundenes Ueberwachungssystem eingebaut, ist der Netzbetreiber auf ...

1997-06-01

129

Marine cables for high power; Sjoekabel med hoeyere effekt  

Energy Technology Data Exchange (ETDEWEB)

A new type of impregnation jelly can be used instead of traditional oil may reduce the formation of cavities in marine high-voltage direct current cables. This provides a foundation for the development of cables with improved insulation and for higher power. This was a conclusion of the Norwegian ''EFFEKT''-project. Using the jelly reduces the size of the cavities substantially and no discharges seem to occur during formation, growth and collapse of cavities. It is also environmentally friendly, since there is no leakage of oil.

2001-07-01

130

Integral testing of the evaluated data files for silicon, zirconium, niobium and iron  

Energy Technology Data Exchange (ETDEWEB)

The evaluated data testing for Si, Zr, Nb and Fe materials has been performed through the analyses of the neutron leakage spectrum from spherical assemblies measured in integral benchmark experiments with (d,t) and Cf fission neutron sources. Intercomparisons of the calculated from BROND-2, ENDF/B-6 and JENDL-3 data files with experimental results are presented.

1994-12-31

131

Influence of MeV electron irradiation on the properties of by ion implantation hydrogenated polysilicon TFTs  

Energy Technology Data Exchange (ETDEWEB)

The influence of MeV electrons irradiation on the gate oxide layers of hydrogenated polysilicon thin film transistors (TFTs) was investigated by measuring gate leakage currents and threshold voltages. The experimental data revealed a decrease of oxide trap density and increase of positive oxide charge. Improvement in the interface roughness and in the oxide quality near the bottom interface was observed.

2006-02-15

132

Influence of MeV electron irradiation on the properties of by ion implantation hydrogenated polysilicon TFTs  

International Nuclear Information System (INIS)

The influence of MeV electrons irradiation on the gate oxide layers of hydrogenated polysilicon thin film transistors (TFTs) was investigated by measuring gate leakage currents and threshold voltages. The experimental data revealed a decrease of oxide trap density and increase of positive oxide charge. Improvement in the interface roughness and in the oxide quality near the bottom interface was observed.

2006-02-01

133

Ceramic dome receiver technology developments  

Energy Technology Data Exchange (ETDEWEB)

The development and experimental demonstration of a high-temperature seal for the SHARE ceramic dome cavity receiver is reported. The mechanical contact seal which was tested on one-foot-diameter silicon-carbide ceramic-dome hardware at pressure differentials to four atmospheres and dome temperatures to 2200/sup 0/F (1200/sup 0/C) showed negligible leakage at expected receiver operating conditions. Potential solar receiver applications for the technology are illustrated.

1980-01-01

134

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

135

Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable ...

2006-11-13

136

Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test  

Energy Technology Data Exchange (ETDEWEB)

Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.

2008-10-15

137

Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test  

International Nuclear Information System (INIS)

Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.

2008-10-01

138

Liquid zone system events at Wolsong Unit 2  

International Nuclear Information System (INIS)

On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) ...

1998-09-07

139

Dynamic load in suppression pool during BWR main steam safety relief valve actuation  

International Nuclear Information System (INIS)

BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure with jet deflector were installed. The test plan and the test result with an actual ...

1979-01-01

140

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable ...

1986-06-09

141

In vitro investigation of biological and technical prosthetic heart valves in MRI: evaluation of possible deflection and heating of the implants; In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung moeglicher Anziehung und Erhitzung der Implantate  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: ...

2000-02-01

142

Successful transcatheter coil embolization of coronary artery to left ventricular fistula associated with absent pulmonary valve with tricuspid atresia in early infancy.  

Science.gov (United States)

Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713

2004-12-01

143

Special features of control and protection for large saturated steam turbines  

International Nuclear Information System (INIS)

For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).

144

Liquid level control system of fast reactor secondary cooling system  

International Nuclear Information System (INIS)

Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).

145

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

146

Fast leak in channel H9  

International Nuclear Information System (INIS)

The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.

147

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

148

Development and application of a diaphragm micro-pump with piezoelectric device  

British Library Electronic Table of Contents (United Kingdom)

In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...

2008-01-01

149

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).

1983-08-26

150

A vortex valve ejector combination for fluidic two diode pumps  

International Nuclear Information System (INIS)

Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).

151

The specific heat consumption and the loss mechanisms at the nozzle-group regulation of steam turbines; Zum spezifischen Waermeverbrauch und den Verlustmechanismen bei der Duesengruppenregelung von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue ...

1995-07-01

152

The safety concept of public gas supply in Germany  

Energy Technology Data Exchange (ETDEWEB)

The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)

1997-09-01

153

The potential of power fluidics for plant protection  

International Nuclear Information System (INIS)

The possibility of using Direct Flow Control (DFC) to avoid catastrophic accidents due to containment breaches in chemical plant is discussed. Recommendations are made for locating fluidic elements, and the effectiveness of simple DFC protection is analysed. More powerful methods of protection are outlined using spin diversion and the complementary properties of fluidic and conventional valves are exploited. (author).

154

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

155

Pressure surge analyses for conventional and nuclear power plants. Druckstossanalysen fuer konventionelle und nukleare Kraftwerke  

Energy Technology Data Exchange (ETDEWEB)

There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)

1993-09-01

156

Power fluidics and the environment  

International Nuclear Information System (INIS)

This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.

157

New safety device announced for nuclear power plants  

International Nuclear Information System (INIS)

An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.

158

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

159

Gas-diesel dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a gas-diesel dual fuel engine apparatus having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode.

1986-08-05

160

Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).

1987-01-01

161

Device for advancing the base of a stoping unit  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.

1980-12-13

162

Thin TiO2 grown by metal?organic chemical vapor deposition on (NH4)2S x -treated InP  

British Library Electronic Table of Contents (United Kingdom)

The electrical characteristics of thin TiO2 films prepared by metal?organic chemical vapor deposition grown on a p-type InP substrate were studied. For a TiO2 film of 4.7?nm on InP without and with ammonium sulfide treatment, the leakage currents are 8.8?10?2 and 1.1?10?4?A/cm2 at +2 V bias and 1.6?10?1 and 8.3?10?4?A/cm2 at ?2?V bias. The lower leakage currents of TiO2 with ammonium sulfide treatment arise from the improvement of interface quality. The dielectric constant and effective oxide charge number density are 33 and 2.5?1013?cm2, respectively. The lowest mid-gap interface state density is around 7.6?1011?cm?2?eV?1. The equivalent oxide thickness is 0.52?nm. The breakdown electric field increases with decreasing thickness in the range of 2.5 to 7.6?nm and reaches 9.3?MV/cm at 2.5?n...

2011-01-01

163

Pressure based leak detection system implanted on the business Unit Exploration and Production of PETROBRAS in Rio Grande do Norte e Ceara; Sistema de deteccao de vazamentos em dutos baseado em pressao implantado na Unidade de Negocios de Exploracao e Producao da PETROBRAS no Rio de Grande do Norte e Ceara  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the test results, the recommendations to ...

2003-07-01

164

Potential for containment leak paths through electrical penetration assemblies under severe accident conditions  

International Nuclear Information System (INIS)

The leakage behavior of containments beyond design conditions and knowledge of failure modes is required for evaluation of mitigation strategies for severe accidents, risk studies, emergency preparedness planning, and siting. These studies are directed towards assessing the risk and consequences of severe accidents. An accident sequence analysis conducted on a Boiling Water Reactor (BWR), Mark I (MK I), indicated very high temperatures in the dry-well region, which is the location of the majority of electrical penetration assemblies. Because of the high temperatures, it was postulated in the ORNL study that the sealants would fail and all the electrical penetration assemblies would leak before structural failure would occur. Since other containments had similar electrical penetration assemblies, it was concluded that all containments would experience the same type of failure. The results of this study, however, show that this conclusion does not hold for PWRs ...

165

Polarised foreground removal at low radio frequencies using rotation measure synthesis: Uncovering the signature of hydrogen reionisation  

CERN Document Server

Measurement of redshifted 21-cm emission from neutral hydrogen promises to be the most effective method for studying the reionisation history of hydrogen and, indirectly, the first galaxies. These studies will be limited not by raw sensitivity to the signal, but rather, by bright foreground radiation from Galactic and extragalactic radio sources and the Galactic continuum. In addition, leakage due to gain errors and non-ideal feeds conspire to further contaminate low-frequency radio obsevations. This leakage leads to a portion of the complex linear polarisation signal finding its way into Stokes I, and inhibits the detection of the non-polarised cosmological signal from the epoch of reionisation. In this work, we show that rotation measure synthesis can be used to recover the signature of cosmic hydrogen reionisation in the presence of contamination by polarised foregrounds. To achieve this, we apply the rotation measure synthesis technique to ...

2010-01-01

166

Hydrological evaluation of landfill performance (HELP) model assessment of the geology at Los Alamos National Laboratory, Technical Area 54, Material Disposal Area J  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is: (1) conduct HELP model variations in weather data, profile characteristics, and hydraulic conductivities for major rock units; (2) compare and contrast the results of simulations; (3) obtain an estimation of leakage through the landfill from the surface to the aquifer; and (4) evaluate contaminant transport to the aquifer utilizing leakage estimation. The conclusions of this paper are: (1) the HELP model is useful to assess landfill design alternatives or the performance of a pre-existing landfill; (2) model results using site-specific data incorporated into the Weather Generator (Trail 4), varied significantly from generalized runs (Trials 1-3), consequently, models that lack site-specific data should be used cautiously; and (3) data from this study suggest that there will not be significant downward percolation of leachate from the surface of the landfill cap to the aquifer-leachate transport rates have been ...

2002-01-01

167

Fuel storage basin seismic analysis  

International Nuclear Information System (INIS)

The 105-KE and 105-KW Fuel Storage Basins were constructed more than 35 years ago as repositories for irradiated fuel from the K East and K West Reactors. Currently, the basins contain irradiated fuel from the N Reactor. To continue to use the basins as desired, seismic adequacy in accordance with current US Department of Energy facility requirements must be demonstrated. The 105-KE and 105-KW Basins are reinforced concrete, belowground reservoirs with a 16-ft water depth. The entire water retention boundary, which currently includes a portion of the adjacent reactor buildings, must be qualified for the Hanford Site design basis earthquake. The reactor building interface joints are sealed against leakage with rubber water stops. Demonstration of the seismic adequacy of these interface joints was initially identified as a key issue in the seismic qualification effort. The issue of water leakage through seismicly induced cracks was also ...

1991-10-15

168

Electrical characteristics of AlxGa1-xN Schottky diodes prepared by a two-step surface treatment  

Science.gov (United States)

Near-ideal Schottky barrier contacts to n-type Al0.22Ga0.78N have been developed by a two-step surface treatment technique. Plasma etching of the AlxGa1-xN surface prior to Schottky metal deposition, combined with sequential chemical treatment of the etched surface, holds promise for developing high quality low-leakage Schottky contacts for low noise applications and for recessed gate high electron mobility transistors. In this work, the effect of postetch chemical treatment of the n-type Al0.22Ga0.78N surface on the performance of the Ni/Au based Schottky contact has been investigated. Three different types of chemical treatment: viz, reactive ion etching, reactive ion etching plus dipping in hot aqua regia, and reactive ion etching plus dipping in hot KOH, are studied. Detailed current-voltage studies of three different surface treated diodes and a comparison with as-deposited diodes reveal significant improvement in the diode characteristics. The latter surface ...

2004-09-01

169

Effects of gamma irradiation on the physical properties of laminated packaging materials. 2. polypropylene-polypropylene, polypropylene-polyethylene, and polyester-polyethylene  

International Nuclear Information System (INIS)

This experiment was done to determine the effects of irradiation on the physical properties of three kinds of laminated packaging materials, i.e. polypropylene-polypropylene, polypropylene-polyethylene, polyester-polyethylene. Observations were made on pinhole production, leakage, oil resistance, resistance against insect penetration, colour, odour tensile strength, elongation at break, seal strength and tear resistance. The samples were irradiated with doses of 0, 5 and 10 kGy, then stored at room temperature and examined after 0, 3, 6 and 12 months of storage. The results showed that irradiation doses up to 10 kGy, as well as storage up to 12 months, did not create pinholes, or leakage in pouches prepared from laminated films. The resistance of the films to oil and insect penetration, the colour, and the odour were also unchanged. Both irradiation and storage treatments had a significant effect on physical properties of the laminated films. ...

170

Combined peritoneography and computerized tomography for evaluating abdominal complications in patients undergoing continuous peritoneal dialysis  

International Nuclear Information System (INIS)

Continuous ambulatory peritoneal dialysis (CAPD) is a generally well-tolerated treatment. However, some patients exhibit such complications as to prevent the continuation of treatment. Peritonitis is the major problem, but the continuation of treatment may also be undermined by different complications, such as peritoneal leakage, hernia, catheter malfunctioning, and scrotal-penile edema; a careful investigation of the patient is always needed in such cases. From November 1985 to February 1990, we examined 20 patients, who had presented with different types of complications in the course of dialysis. Peritoneography demonstrated 3 cases of abdominal hernias, 2 cases of patency of the peritoneal-vaginal duct, and 2 cases of catheter obstruction. Peritoneal CT allowed the identification of leakage in 3 patients, while the combined use of the two techniques showed adhesions or pathologic peritoneal recesses in 7 cases. In 3 patients normal patterns ...

1985-11-01

171

The application of platinum-silicide anode layer to decrease the static and turn-off losses in high-power P-i-N diode  

Energy Technology Data Exchange (ETDEWEB)

The platinum-silicide layer was investigated as the anode contact of a high-power P-i-N diode. The thermal stability at 700 deg. C was found sufficient for the purpose of Pt in-diffusion from the platinum-silicide layer into the volume. The diffusion, which was controlled using the radiation defects resulting from the 10 MeV alpha particle irradiation, represents a new local lifetime control in the float zone silicon with very low-leakage current, while keeping the benefits of traditional approaches.

2003-06-02

172

Self-optimized Coverage Coordination and Coverage Analysis in Femtocell Networks  

CERN Document Server

This paper proposes a self-optimized coverage coordination scheme for two-tier femtocell networks, in which a femtocell base station adjusts the transmit power based on the statistics of the signal and the interference power that is measured at a femtocell downlink. Furthermore, an analytic expression is derived for the coverage leakage probability that a femtocell coverage area leaks into an outdoor macrocell. The coverage analysis is verified by simulation, which shows that the proposed scheme provides sufficient indoor femtocell coverage and that the femtocell coverage does not leak into an outdoor macrocell.

2009-01-01

173

Modified spontaneous emission rate in three-dimensional layer-by-layer photonic crystals with planar defects  

Science.gov (United States)

A finite three-dimensional layer-by-layer photonic crystal with planar defects in a layer is shown to drastically modify the spontaneous emission rate of an embedded dipole. Finite-difference time-domain calculations with one quarter symmetric boundary condition and perfectly matched layer demonstrate the strong enhancement effects induced by the cavity resonance of defect modes and band-edge resonant modes. Simulation shows that the emission spectra are quite different when the position or polarization of the dipole is changed. Moreover, the extraction efficiency is calculated to observe the percentage of light leakage through a substrate.

2010-01-01

174

Fourth international seminar on horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

The general objective of the International Seminars of Horizontal Steam Generator Modelling has been the improvement in understanding of realistic thermal hydraulic behaviour of the generators when performing safety analyses for VVER reactors. The main topics presented in the fourth seminar were: thermal hydraulic experiments and analyses, primary collector integrity, feedwater distributor replacement, management of primary-to-secondary leakage accidents and new developments in the VVER safety technology. The number of participants, representing designers and manufacturers of the horizontal steam generators, plant operators, engineering companies, research organizations, universities and regulatory authorities, was 70 from 10 countries.

1997-12-31

175

Compilation and appraisal of methods to assess thermal aging in computer controls before and during their operation in nuclear power plants  

International Nuclear Information System (INIS)

The intention is to define what is required as evidence of continuous resistance to malfunction to ensure operational safety according to Rule KTA 3706 'Proof of electrical component safety under leakage conditions'. As a supporting part of this task, a recognized scientific and engineering basis on which to define the requirements has to be set up. The report is a compilation of studies and development work which could contribute useful improvements to the assessment methodology applied to thermal aging (Arrhenius model, ndeg-rule, Eyring model, Inverse-power model, according to KTA Rule 3505) of electronic controls or electrical components. (orig./DG).

176

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the ...

2008-02-21

177

CRC handbook of nuclear reactors calculations. Vol. II  

International Nuclear Information System (INIS)

This handbook breaks down the complex field of nuclear reactor calculations into major steps. Each step presents a detailed analysis of the problems to be solved, the parameters involved, and the elaborate computer programs developed to perform the calculations. This book bridges the gap between nuclear reactor theory and the implementation of that theory, including the problems to be encountered and the level of confidence that should be given to the methods described. Volume II: Monte Carlo Calculations for Nuclear Reactors. In-Core Management of Four Reactor Types. In-Core Management in CANDU-PHW Reactors. Reactor Dynamics. The Theory of Neutron Leakage in Reactor Lattices. Index.

178

CMOS/SOI hardening at 100 MRAD (SiO_2)  

International Nuclear Information System (INIS)

Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.

1990-07-16

179

Investigation of flora and fauna species of Lake Baikal by electron-probe microanalysis  

International Nuclear Information System (INIS)

Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. ...

180

Simplified methods in the estimation of the K-value of insulated cargo holds on ships  

Energy Technology Data Exchange (ETDEWEB)

The problem of buried steelwork in cargo hold insulation has been investigated by several using empirical methods. These efforts have resulted in correction factors that serve as a useful aid in the complex task of estimating the K-value of a ship`s cargo holds for the correct dimensioning of the refrigeration plant. Today, the advent of the digital computer has established numerical methods of analysis as a common working tool among practicing engineers. For estimating the flow in cases of buried steelwork that cannot be handled by correction factors, this is an effective approach. This study is an analytical/numerical investigation of the effect that buried steelworks have on the heat leakage across cargo hold walls. It aims at providing enlightenment on the physical significance of the parameters influencing the problem and developing practically simple methods for predicting the heat leakage across the hold walls. The study is set in the ...

1992-03-01

181

Fundamental study on leak detection of underground gas pipeline using passive acoustic method; Judogata onkyo keisoku ni yoru maisetsu gas dokan hason kasho no kenshutsu ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole diameter, spectra having the dominant frequency in the region of 1 kHz or higher were measured. In addition, it ...

1997-05-27

182

Failure criteria and fission products trapping effect at containment penetrations under severe accident conditions (2)  

Energy Technology Data Exchange (ETDEWEB)

Since the integrity of the containment penetrations was confirmed under accident management (AM) conditions in the former test, failure criteria tests and aerosol trapping tests were carried out using low-voltage modules and flange gaskets of an actual plant under severe accident (SA) conditions, without AM. The safety margin for failure temperature of the penetrations and the credit for fission product (FP) aerosol trapping effect along the leakage paths of the degraded penetrations were evaluated in the present tests. Failure temperature of the penetrations ranged from 270 to 300degC for low-voltage modules and 300 to 350degC for flange gaskets under 0.4 to 1.0 MPa conditions. Pressure dependency on failure temperature was small. This means that the safety margin of failure temperature under AM condition is more than 70degC. By introducing a equivalent leak area for the damaged test pieces, total leak area was estimated which was smaller than the value used in ...

1999-07-01

183

An extended CT scale technique for evaluating periprosthetic bone lesions - an in vitro study; Extended-field CT-Technik zur Evaluation von periprothetischen Knochenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In the present study the reduction of artifacts using an extended CT scale technique was examined in 5 vitallium and 5 titanium-aluminium-vanadium tumor prostheses. Methods: 5 titanium-aluminium-vanadium and 5 vitallium distal femur Mutars {sup trademark} tumor prostheses (Mutars {sup trademark} - Modular Universal Tumor And Revision System) were implanted in 10 human femur specimens. 110 artifical drill hole lesions of 1 mm, 2 mm, 3 mm, 5 mm and 8 mm diameter were placed in the bone around the hexagonal stem of the tumor prosthesis and furthermore in the proximal part of the femur. All specimens were examined using conventional CT and an extended CT scale technique in a slice thickness of 3 mm. Results: In the proximal part of the femur all drill holes could be detected using 3 mm slices, no artefacts were observed. Along the hexagonal stem smooth lines arising from each hexagonal plane could be observed. This made it impossible to detect a 1 mm drill in 1 vitallium and in 1 ...

2001-12-01

184

Thermal analysis of spent fuel in rehearsal and emergency storage facility (RESF) under station blackout (SBO) in TAPS - 4  

International Nuclear Information System (INIS)

The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the modified RESF system ...

2006-11-13

185

The new BMW 4-cylinder engine in the 318i; Der neue BMW Vierzylindermotor im 318i  

Energy Technology Data Exchange (ETDEWEB)

The BMW four-cylinder two-valve engine was first launched in September 1987 as a 1.8 l engine and was described in detail in [1]. After initial optimisation for model year 94, four years later the engine has undergone a complete technical revision. From model year 98, the four-cylinder two-valve engine with appropriate exhaust emission technology will satisfy the EU3 class for exhaust emissions. (orig.) [Deutsch] Der BMW Vierzylinder-Zweiventilmotor wurde im September 1987 als 1,8-l-Motor erstmals vorgestellt und in [1] ausfuehrlich beschrieben. Nach einer ersten Optimierungsueberarbeitung zum Modelljahr 1994 wurde nun eine grundlegende technische Ueberarbeitung vorgenommen. Der Vierzylindermotor mit Zweiventiltechnik erfuellt als Antriebsaggregat in Verbindung mit einer entsprechenden Abgastechnik bereits ab Modelljahr 1998 die EU 3-Stufe fuer Abgasemissionen. (orig.)

1998-05-01

186

The influence of the layout-admission pressure loss on the control-statical properties of steam turbines; Der Einfluss des Auslegungs-Einstroemdruckverlustes auf die regelstatischen Eigenschaften von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The complete determination of stroke/throughput curves at steam turbines for arbitrary valve positions usually only follows after the fundamental layout of the control valves, of the possible nozzle segments and of the turbine blading. A general fundamental equation and some design norms based on it are presented which may serve already before a fluidic layout of the turbine in detail as an optimizing predetermination of the properties concerning pressure loss and control statics of the metering components in the admission area. (orig.) [Deutsch] Die vollstaendige Bestimmung der Hub-/Durchsatzkurven an Dampfturbinen fuer beliebige Ventilstellungen erfolgt ueblicherweise erst nach der Grundauslegung der Stellventile, etwaiger Duesensegmente und der Turbinenbeschaufelung. Es werden eine allgemeine Grundgleichung und einige auf ihr aufbauende Entwurfsregeln angegeben, die zu einer optimierenden Vorabbestimmung der druckverlustbezogenen ...

1997-06-01

187

Some medical applications of thermomechanically treated titanium nickelide  

Energy Technology Data Exchange (ETDEWEB)

An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first ...

2001-11-01

188

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

Energy Technology Data Exchange (ETDEWEB)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

189

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

International Nuclear Information System (INIS)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

190

Radioisotopic techniques for noninvasive detection of platelet deposition in bovine-tissue mitral-valve prostheses and in vitro quantification of visceral microembolism in dogs  

International Nuclear Information System (INIS)

Platelet deposition on bovine pericardial-tissue mitral-valve prostheses in 11 dogs was observed noninvasively by use of "1"1"1In-labeled platelets and quantified after sacrifice at one (n . 3), 14 (n . 3), and 30 (n . 5) days postimplantation (300-400 microCi of labeled platelets having been injected 24 hours previously). Thrombosis on the sewing ring and pericardial leaflets at one and 14 days and on the leaflets at 30 days was delineated in scintiphotos. In vitro quantification (% injected dose) indicated that the leaflets, sewing ring, and perivalvular tissue retained 0.904% of labeled platelets at one day postimplantation, 0.198% at 14 days, and 0.040% at 30 days. Platelet half-life was reduced to 38 hours at 21 days postimplantation but returned toward the normal (50 hours) with fibrous ingrowth in the sewing ring. Microembolism in lung and kidney, as measured by tissue/blood radioactivity ratio, also was decreased significantly at 30 days. "1"1"1In-labeled ...

191

Modeling the internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A flexible and computationally economical model of the internal combustion engine was developed for use on large digital computer systems. It is based on a system of ordinary differential equations for cylinder-averaged properties. The computer program is capable of multicycle calculations, with some parameters varying from cycle to cycle, and has restart capabilities. It can accommodate a broad spectrum of reactants, permits changes in physical properties, and offers a wide selection of alternative modeling functions without any reprogramming. It readily adapts to the amount of information available in a particular case because the model is in fact a hierarchy of five models. The models range from a simple model requiring only thermodynamic properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. Among its many features the model includes heat transfer, valve timing, ...

1985-03-01

192

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

193

Fault detection and fault diagnosis system for engine; Engine no kosho yochi shindan system  

Energy Technology Data Exchange (ETDEWEB)

The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and degradation of engine parts, it can transfer ...

1996-03-29

194

Establishment of Database Program for In-service Test Management in Nuclear Power Plants  

International Nuclear Information System (INIS)

In-service Test (IST) of the nuclear power plant is very important to maintain the safety of the plants. The safety features of nuclear power plant are based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves. Because of the importance of the IST, most of nuclear power plants should designate the IST department and personnel. Because the nuclear power plants of Korea have several types and the designs and operations are different from each other, the methods and experiences are various for the management of the IST program. However, there are no medium to communicate with each other and exchange the tips and information about IST program and education and discussion would be required to apply a consistent code. The nature of the IST Standardization Management Data Base (SMDB) is to exchange opinions and documents about IST program and ...

2010-10-01

195

Development of an efficient, low-NOx domestic gas-range cooktop. Phase 3. Annual technical report, January 1986-December 1986  

Science.gov (United States)

The objective of the program is to develop a domestic cooktop with low-NOx emissions and high efficiency. During the first two phases of the program, three design concepts were developed, and two versions of developmental prototypes using the IR-Jet approach were fabricated and tested. The third phase was initiated to address the design issues of burner turndown and modulation and to conduct the field test of a prototype with one IR-Jet and three conventional burners. Two prototypes containing one IR-Jet and three conventional burners and utilizing blower speed control for air/gas modulation were fabricated. One unit employed a brushless dc motor and the other a 2-pole ac motor. The ac motor prototype was field tested. Field testing showed the need for a mechanical air/gas valve for modulation and for a 1500 Btu/hr simmer setting. A 4-inch-diameter stepped-tile configuration provided input rates from 1500 to 8000 Btu/hr. A manufacturer, Copreci of Spain, started ...

1987-06-01

196

Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon  

Energy Technology Data Exchange (ETDEWEB)

To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and ...

1991-10-15

197

Combustion system for dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

This patent describes in an dual gas-liquid fuel four cycle engine having cylinders and wherein each cylinder is operatively connected thereto and each cylinder has a piston, two inlet valves, two exhaust valves and a first liquid fuel injector. It comprises: at least one fuel torch cell operatively connected to at least one cylinder, the torch cell having a torch cell nozzle at one end thereof and the other end having appropriate means to connect the torch cell to a fuel supply, a second fuel injector mounted in the torch cell at a predetermined angle to an axis of the torch cell, the torch cell defining an auto-ignition chamber, the second fuel injector being in operative communication with the auto-ignition chamber by an injector nozzle passageway, the injector nozzle passageway entering the auto-ignition chamber at a predetermined angle relative to the axis, and a torch nozzle passage connecting the auto-ignition chamber with the cylinder ...

1990-10-30

198

The Bevatron liquid nitrogen circulation system  

Science.gov (United States)

A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.

1987-03-01

199

Testing of the 1-MWth bench-model cavity-receiver steam generator  

Science.gov (United States)

A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)

200

Seconds capacity reserve and heat consumption with different operating procedures of steam turbines. Sekundenleistungsreserve und Waermeverbrauch bei verschiedenen Betriebsarten von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).

1989-09-01

201

Reducing the breakdowns and energy consumption in pressure regulating stations by rationalizing the heating of gas  

Energy Technology Data Exchange (ETDEWEB)

Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.

1982-04-01

202

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

203

Method and apparatus for operation of a dual fuel compression ignition combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A dual fuel engine control system for controlling the power output of a dual fuel compression ignition engine. The engine includes mixing means for combining an oxidizer and a primary fuel at a substantially constant ratio of oxidizer to primary fuel. The power output of the engine is controlled through the use of a throttle valve controlling the quantity of combustible mixture delivered to the combustion chamber. The fuel control system minimizes the quantity of ignition fuel required by controlling the quantity of combustible mixture rather than the fuel of air ratio. (author) figs.

1994-03-03

204

Isolated laevocardia and corrected transposition of the great vessels with total situs inversus  

International Nuclear Information System (INIS)

Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).

205

Improvement of assessment methodology for fluid flow characteristics of passive flow control device  

International Nuclear Information System (INIS)

The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.

2002-10-01

206

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1989-01-01

207

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1988-01-01

208

Evolution of ASTEC V1.2 rev.1 code for WWER-1000 reactors/SBO sequence  

International Nuclear Information System (INIS)

In this paper a comparison between calculations of severe accidents occurred from WWER-1000 with ASTEC code specified for an event of full unloading with relief valves stuck opened with no hydroaccumulators intervention is presented. The purpose of the analyses provided is to present the relationship between the improvements of the actual version (ASTEC Vl.2 rev. 1) and ASTEC V1.1 p2 like: code modifications, incoming data improvements. Such discrepancies are to be examined. Case by case suggestions for ASTEC improvements are to be provided.

2006-06-14

209

Error evaluation of the linearized equation of servo valve in hydraulic control systems  

International Nuclear Information System (INIS)

In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.

2001-11-01

210

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

211

Computer aided monitoring of pump efficiency by using ART2 neural networks; ART2 nyurarunettowaku niyoru ponpuseino no rekka shindan shien  

Energy Technology Data Exchange (ETDEWEB)

As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)

2000-05-10

212

Autogenous electrolyte, non-pyrolytically produced solid capacitor structure  

Energy Technology Data Exchange (ETDEWEB)

A solid electrolytic capacitor having a solid electrolyte comprising manganese dioxide dispersed in an aromatic polyamide capable of further cure to form polyimide linkages, the solid electrolyte being disposed between a first electrode made of valve metal covered by an anodic oxide film and a second electrode opposite the first electrode. The electrolyte autogenously produces water, oxygen, and hydroxyl groups which act as healing substances and is not itself produced pyrolytically. Reduction of the manganese dioxide and the water molecules released by formation of imide linkages result in substantially improved self-healing of anodic dielectric layer defects.

1998-01-01

213

W-12 valve pit decontamination demonstration  

Energy Technology Data Exchange (ETDEWEB)

Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste connection. Remote ...

1995-12-01

214

Summary of ACSL Simulations of the MSRE Auxiliary Charcoal Bed Vacuum System  

Energy Technology Data Exchange (ETDEWEB)

The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance acceptable; (1) Remove valve PCV4. (2) Modify the flow controllers ...

2000-10-26

215

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

216

The optimal path of piston motion for Otto cycle with linear phenomenological heat transfer law  

British Library Electronic Table of Contents (United Kingdom)

An Otto cycle engine with internal and external irreversibilities of friction and heat leakage, in which the heat transfer between the working fluid and the environment obeys linear phenomenological heat transfer law [q ?? ?(T ?1)], is studied in this paper. The optimal piston motion trajectory for maximizing the work output per cycle is derived for the fixed total cycle time and fuel consumed per cycle. Optimal control theory is applied to determine the optimal piston trajectories for the cases of with and without piston acceleration constraint on each stroke and the optimal distribution of the total cycle time among the strokes. The optimal piston motion with acceleration constraint for each stroke consists of three segments, including initial maximum acceleration and final maximum decel...

2009-01-01

217

TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR  

Energy Technology Data Exchange (ETDEWEB)

California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof ...

2010-03-01

218

Significance of microstructure for a MOCVD-grown YSZ thin film gas sensor  

Energy Technology Data Exchange (ETDEWEB)

The authors report the fabrication and characterization of a low temperature (200--400 C) thin film gas sensor constructed from a MOCVD-grown yttria-stabilized zirconia (YSZ) layer sandwiched between two platinum thin film electrodes. A reproducible gas-sensing response is produced by applying a cyclic voltage which generates voltammograms with gas-specific current peaks and shapes. Growth conditions are optimized for preparing YSZ films having dense microstructures, low leakage currents, and maximum ion conductivities. In particular, the effect of growth temperature on film morphology and texture is discussed and related to the electrical and gas-sensing properties of the thin film sensor device.

1996-11-01

219

Recursive distribution method for probabilistic fracture mechanics and its application to evaluation of LWR piping  

Energy Technology Data Exchange (ETDEWEB)

The present authors have previously developed a new method for Probabilistic Fracture Mechanics (PFM), which they call Recursive Distribution (RD) method. The method is based on the construction of the Lebesgue-Stieltjes measure through a deterministic mapping defining a crack growth process. In the present paper, its theoretical background is first discussed, and the Lebesgue decomposition of the measure is given. Then a numerical example of a Light Water Reactor (LWR)`s piping problem is solved by the present method, and the results are compared with those of the Monte Carlo (MC) method. In addition to leakage probability, a variation in stress cycles of the marginal distribution of an aspect ratio of a semi-elliptical surface crack is calculated, which will be used in a study on LBB evaluation.

1996-12-01

220

Rapamycin (sirolimus) protects against hypoxic damage in primary heart cultures via Na^+/Ca^2^+ exchanger activation  

British Library Electronic Table of Contents (United Kingdom)

Aims: Rapamycin (sirolimus) is an antibiotic that inhibits protein synthesis through mammalian targeting of rapamycin (mTOR) signaling, and is used as an immunosuppressant in the treatment of organ rejection in transplant recipients. Rapamycin confers preconditioning-like protection against ischemic-reperfusion injury in isolated mouse heart cultures. Our aim was to further define the role of rapamycin in intracellular Ca^2^+ homeostasis and to investigate the mechanism by which rapamycin protects cardiomyocytes from hypoxic damage. Main methods: We demonstrate here that rapamycin protects rat heart cultures from hypoxic-reoxygenation (H/R) damage, as revealed by assays of lactate dehydrogenase (LDH) and creatine kinase (CK) leakage to the medium, by MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-d...

2011-01-01

221

Numerical simulation of the flow field in a high specific speed radial fan; Numerische Simulation der Stroemung in einem Radialventilator mit hoher spezifischer Drehzahl  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the application of the commercial CFD-code FLUENT 6.1 to the numerical simulation of the flow field in a high specific speed radial fan. Two-dimensional as well as three-dimensional computations are performed using the steady 'Frozen-Rotor method' as well as the unsteady 'Sliding-Mesh method'. The predicted performance curves of the radial fan are compared with the results obtained from measurements on a test stand. Due to the relatively low computation times, the 'Frozen-Rotor method' can be used routinely for design purposes. The results of this approach can be improved if the leakage flow through the gap between the inlet nozzle and the impeller is taken into account. (orig.)

2005-11-01

222

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would permit to exercise casting in the optimum ...

223

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

224

Impacts on Competitiveness from EU ETS. An analysis of the Dutch Industry  

Energy Technology Data Exchange (ETDEWEB)

The EU emissions trading scheme (ETS) was launched in 2005 to cap CO2 emissions from large industrial facilities and electricity producers. The European Commission is currently designing the post 2012 EU ETS, as outlined in COM(2008)16. Novel to this system is that a greater part of the rights will be auctioned. Auctioning in general assures a greater deal of efficiency compared to (certain types of) free allocation, lowers the administrative costs and prevents eventual windfall profits. However, auctioning also implies a potential loss of competitiveness for industry. If no international agreement on future climate policies is reached, firms may not be able to pass on the higher costs to their customers and may be faced with a loss in profitability and the threat of import substitution. In any emission trading scheme with an absolute cap, a relocation of production that is not covered by CO2 targets implies an increase in global CO2 emissions. This phenomenon has been labelled as ...

2008-01-15

225

Greenhouse gas emission inventory based on full energy chain analysis  

International Nuclear Information System (INIS)

Methodology, characteristics, features and results obtained for greenhouse gases within the recent Swiss LCA study 'Environmental Life-Cycle Inventories of Energy Systems' are presented. The focus of the study is on existing average Full Energy Chains (FENCHs) in the electricity generation mixes in Europe and in Switzerland. The systems, including coal (hard coal and lignite), oil, natural gas, nuclear and hydro, are discussed one by one as well as part of the electricity mixes. Photovoltaic systems are covered separately since they are not included in the electricity mixes. A sensitivity analysis on methane leakage during long-range transport via pipeline is shown. Whilst within the current study emissions are not attributed to specific countries, the main sectors contributing to the total GHGs emissions calculated for the various FENCHs are specified. (author). 10 refs, 10 figs, 9 tabs.

1996-07-01

226

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

227

Effects of heat loss as percentage of fuel's energy, friction and variable specific heats of working fluid on performance of air standard Otto cycle  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to analyze the effects of heat loss characterized by a percentage of the fuel's energy, friction and variable specific heats of working fluid on the performance of an air standard Otto cycle with a restriction of maximum cycle temperature. A more realistic and precise relationship between the fuel's chemical energy and the heat leakage that is based on a pair of inequalities is derived through the resulting temperature. The variations in power output and thermal efficiency with compression ratio, and the relations between the power output and the thermal efficiency of the cycle are presented. The results show that the power output as well as the efficiency where maximum power output occurs will increase with increase of the maximum cycle temperature. The temp...

2008-01-01

228

Detached divertor plasmas in JET  

Energy Technology Data Exchange (ETDEWEB)

In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.

1994-07-01

229

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

230

Contamination and restoration of groundwater aquifers  

Energy Technology Data Exchange (ETDEWEB)

Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the subsurface; and field testing and evaluation of methods proposed to restore and cleanup contaminated aquifers. In this review, ...

1993-04-01

231

Characterization of polysilicon thin-film transistors with asymmetric source/drain implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of asymmetry tilt angle ion implantation on polysilicon thin-film transistors (TFTs) device characteristics are investigated. This asymmetric source/drain (S/D) TFTs structure exhibits low leakage current and suppressed kink effect due to the relief of higher electric field near the drain junction side. It is shown that the optimal implantation tilt angle is 30 deg. in our annealing condition. And the anomalous off-state current is more than two orders of magnitude lower than that of the conventional TFTs. By well controlled the LDD region, this structure can act as a conventional structure in the on-state and the turn-on current will not be degraded. Besides, the device under severe hot carrier bias stress shows better hot carrier endurance.

2005-08-01

232

Buried-heterostructure semiconductor Raman laser with threshold pump power less than 1 W  

Energy Technology Data Exchange (ETDEWEB)

The low-power operation of a semiconductor buried-heterostructure Raman laser is reported. We are developing these devices for very wide-band optical communication in the terahertz frequency region. It has a structure with a GaP active layer and Al{sub {ital x}}Ga{sub 1{minus}{ital x}}P cladding layers, which are grown by the temperature-difference method under controlled vapor pressure. By making the stripe width 30--40 {mu}m, we have obtained a threshold pump power of 500 mW. A low-threshold semiconductor Raman laser can be pumped by semiconductor injection lasers. We have measured the optical loss of the waveguide and detected the contribution from scattering and leakage at heterointerfaces.

1989-12-01

233

Basic characteristics of centrifuges, (2)  

International Nuclear Information System (INIS)

The presence of an extraneous light gas must be taken into account in consideration of centrifugal separation of uranium isotopes, when there is inevitable leakage of such a gas through the gas sealant and/or leaking in from the atmosphere. Consideration is first given to the influence of the presence of the light gas on the maximum separative power. Then the basic equation for isotope separation containing a light gas is derived from Hirschfelder's diffusion equations. This equation is solved and the separative performance is expressed in terms of the shape factor and reflux parameter. The formulas for expressing the flow configurations of the gases are obtained for a simple model in which inflow and outflow prevail throughout the centrifuge. The corresponding equation for a model in which the gases flow in two concentric thin streams is also derived. It is concluded that the influence provided by the presence of a light gas is quite significant if the gas ...

234

A radiation monitoring system for nuclear fusion devices  

International Nuclear Information System (INIS)

Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)

2005-12-01

235

Formation and capacitance of Nb{sub 2}O{sub 5} thin film on aluminum foil by sol-gel process; Zoru-geru ho niyoru aruminiumuhakujo eno Nb{sub 2}O{sub 5} hakumaku no sakusei to yoryotokusei  

Energy Technology Data Exchange (ETDEWEB)

Nb{sub 2}O{sub 5} thin films were formed on aluminum foils by a sol-gel process in order to increase the capacitance of the aluminum foils which are used as aluminum electrolytic capacitors. Investigations focussed on the preparation and characterization of the coating solution, the formation of Nb{sub 2}O{sub 5} thin films on aluminum foils, and the heat treatment and anodization of the films. The phase transition and electrical properties, such as capacitance, leakage current, and withstand voltage of the Nb{sub 2}O{sub 5} thin films were also measured. The Nb{sub 2}O{sub 5} thin films annealed at temperatures below 550 degree C were found to be amorphous, but they were crystallized to the orthorhombic phase by annealing at temperatures higher than 580 degree C. The capacitance of the coated samples increased with an increase in the thickness of the formed Nb{sub 2}O{sub 5} thin films, but an increase in leakage current and a decrease in ...

1999-12-01

236

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree well with the ...

2003-07-01

237

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

International Nuclear Information System (INIS)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree well with the ...

2003-10-05

238

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam ...

1999-05-01

239

Tickover speed controller for car engines  

Energy Technology Data Exchange (ETDEWEB)

In general, the tickover speed of a car engine is made sufficiently high, in order to permit an assumed maximum load to be taken from the engine at tickover. This setting of the tickover speed is usually done by stops in the fuel supply. Matching the actual load would lead to lower fuel consumption, without any danger of the engine stalling. The purpose of the invention is to provide a tickover speed controller, so that the tickover speed is adjusted by electronic control equipment, independently of the machine load. The fuel consumption on tickover is reduced and the emission of noxious substances is decreased. The electro-magnetic control of the throttle valve tickover setting is explained by extensive section drawings of the system. This process dispenses with the special tickover cams for a cold start.

1980-05-22

240

The influence of bowl offset on air motion in a direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The influence of bowl offset on motored mean flow and turbulence in a direct injection diesel engine has been examined with the aid of a multi-dimensional flow code. Results are presented for three piston geometries. The bowl geometry of each piston was the same, while the offset between the bowl and the cylinder axis was varied from 0.0 to 9.6% of the bore. The swirl ratio at intake valve closing was also varied from 2.60 to 4.27. It was found that the angular momentum of the air at TDC was decreased by less than 8% when the bowl was offset. Nevertheless, the mean (squish and swirl) flows were strongly affected by the offset. In addition, the distribution of turbulent kinetic energy (predicted by the /delta/-e model) was modified. Moderate increases (10% or less) in mass averaged turbulence intensity at TDC with offset were observed.

1988-01-01

241

The chance finding of an aneurysm of the right sinus of Valsalva in an 11-year-old child with a ventricular septal defect and a pericardial effusion  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...

2011-01-01

242

Surge-line thermal stratification: Displacements and fatigue damage computations  

Energy Technology Data Exchange (ETDEWEB)

Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. Alternative solutions for coping with ...

1989-01-01

243

Start safety apparatus for internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.

1986-09-09

244

Powertrain and apparatus using a continuously variable ratio transmission to improve fuel economy  

Energy Technology Data Exchange (ETDEWEB)

An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are optimized to produce exceptional fuel economy.

1981-07-28

245

New technology for purging the steam generators of nuclear power plants  

British Library Electronic Table of Contents (United Kingdom)

A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...

2011-01-01

246

Natural radioactive materials in oil and gas industry  

International Nuclear Information System (INIS)

Oil and gas production and processing operations sometimes cause naturally occurring radioactive materials (NORM) to accumulate at elevated concentrations in by-product waste streams. The sources of most of the radioactivity are isotopes of "2"3"8U and "2"3"2Th series, which are naturally present in the subsurface formations from which oil and gas are produced. NORM waste may cause problems in the operations of installations by plugging perforations, clogging tubular and valves then restricting flow. Therefore, plants or equipment have to be refurbished and decontaminated before reuse to avoid radioactive waste or surface contaminated object. There are two options for safe disposal of scale and sludge produced from NORM Descaling Facility : 1- Injection into an abandoned production well. 2- The construction of a near surface depository. These options are assumed to be environmental friendly disposal options. (author)

2010-03-01

247

Method of feeding a coolant into a reactor  

International Nuclear Information System (INIS)

Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).

248

Measuring air movement locally in the combustion chambers of a direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

Measurements of smoke and NO emissions from a direct-injection diesel engine have shown that they are indeed influenced by inlet port design, even though the swirl numbers for the ports may be identical. The swirl numbers of the three ports used (tangential port, helical port and helical port with masked valve) were measured on a steady-state test rig using a paddle-wheel anemometer and impulse swirl meter. Flow measurements were carried out under motoring conditions with a constant-temperature, hot-wire anemometer. Is was possible to find a correlation between flow data and exhaust data as far as the in-cylinder air motion over a certain time interval is concerned.

1983-02-01

249

Influence of performance characteristic of a gaseous fuel supply system on hydrocarbon emissions of a dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

The performance of the gaseous fuel supply and its influence on hydrocarbon (HC) emissions of dual-fuel engines have been investigated. A new design of manifold respirators with mixers is also presented in the paper. The design of the gaseous fuel supply system has a great influence on HC emissions in the dual-fuel engine at light load. The problem of scavenging is discussed and solved by using the manifold respirators in the dual-fuel engine. It performs the function of retarding the gaseous fuel entry timing from the moment of intake valve opening, and its delaying effects have been measured and tested. Experimental results show that the manifold respirator gives the best performance in reducing HC emissions compared with a common pipe mixer and a respirator with bo miser. In addition, the mixing effects are sensitive to the mixer configuration. (Author)

2000-11-01

250

Gene Regulation of Extracellular Matrix Remodeling in Human Bone Marrow Stem Cell-Seeded Tissue-Engineered Grafts  

British Library Electronic Table of Contents (United Kingdom)

Tissue-engineered heart valves are prone to early structural deterioration. We hypothesize that cell?scaffold interaction and mechanical deformation results in upregulation of genes related to osteogenic/chondrogenic differentiation and thus changes extracellular matrix (ECM) composition in human bone marrow mesenchymal stem cell (hBMSC)-derived tissue-engineered grafts. hBMSC were expanded and seeded onto poly-glycolic acid/poly-lactic acid scaffold for 14 days. Seeded tissue-engineered constructs (TEC) were subjected to cyclic flexure for 24?h, whereas control TEC was maintained in roller bottles for the same duration. hBMSC, TEC, and mechanically deformed TEC were subjected to gene-array and histological analysis. Expression levels of RNA and/or protein markers related to chondrogenesis...

2011-01-01

251

Fuel injection control for diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.

1987-11-10

252

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel  

British Library Electronic Table of Contents (United Kingdom)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...

2010-01-01

253

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...

254

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

255

Detection of intracardiac calcification using Fuji computed radiography  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).

1986-01-01

256

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

257

Computerized pressure monitoring and control of Hydro-Quebec`s fluid-filled high-voltage underground cable network in Montreal  

Energy Technology Data Exchange (ETDEWEB)

The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management tools. 1 ref., 1 tab., 4 figs.

1996-08-01

258

Chitons (Mollusca, Polyplacophora) du Pleistocene tardif et de l'Holocene d'Uruguay : paleobiogeographie et reconstruction paleoenvironnementale aux latitudes moyennes de l'Atlantique du sud-ouest  

British Library Electronic Table of Contents (United Kingdom)

Here we present a revision of the fossil record of chitons (Mollusca, Polyplacophora) of Late Pleistocene and Holocene marine deposits of Uruguay and discuss their potential for palaeoenvironmental reconstruction. Chitons were recorded as isolated valves in bivalve- and gastropod-rich assemblages. They are represented by the species Chaetopleura angulata (Spengler), C. isabellei (d'Orbigny), C. asperrima (Gould) and Ischnochiton striolatus (Gray). The last two species are recorded for the first time as fossils not only in Uruguay but also in South America. Exclusively recorded for the Late Pleistocene is the warm water species I. striolatus, whose current southern range limit is located in Santa Catarina, Brazil. Higher temperatures than at present are inferred for the Uruguayan coast duri...

2011-01-01

259

Characterization and effect of using cotton methyl ester as fuel in a LHR diesel engine  

International Nuclear Information System (INIS)

In the present study, surfaces of cylinder head, piston, exhaust and inlet valve of a four-stroke, direct injection, single cylinder diesel engine were coated with molybdenum (Mo) by plasma spray method. Thus, thermal barrier characteristic was brought to these parts. Variances in performance and emission values of cotton methyl ester and 2D fuel mixtures were studied in the ceramic coated and uncoated engines under the same running conditions. Performance (6.0% for specific fuel consumption) and emission values (up to 18.0% for CO, 8.0% for smoke density) of the test fuel were improved in the coated engine compared with the uncoated engine. NO_x increase (4.5%) with the increased temperatures expected in the coated engine.

2011-01-01

260

Calculation model testing for the case of rcs hot collector rupture inside the horizontal steam generator of VVER-440 NPP  

Energy Technology Data Exchange (ETDEWEB)

The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).

1993-12-31

261

Calculation model testing for the case of rcs hot collector rupture inside the horizontal steam generator of VVER-440 NPP  

International Nuclear Information System (INIS)

The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).

1992-09-29

262

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.

1985-07-03

263

An historical view of the pineal gland and mental disorders  

British Library Electronic Table of Contents (United Kingdom)

Since Classical Antiquity numerous authors have linked the origin of some mental disorders to physical and functional changes in the pineal gland because of its attributed role in humans as the connection between the material and the spiritual world. The pineal organ was seen as a valve-like structure that regulated the flow of animal spirits through the ventricular system, a hypothesis that took on more vigour during the Middle Ages and the Renaissance. The framework for this theory was ''the three cells of the brain'', in which the pineal gland was even called the ''appendix of thought''. The pineal gland could also be associated with the boom, during this period, of certain legends about the ''stone of folly''. But the most relevant psychopathological role of this organ arrived with Des...

2011-01-01

264

The new 2.2 l ECOTEC aluminium engine by Opel; Der neue 2,2-l-ECOTEC-Aluminium-Motor von Opel  

Energy Technology Data Exchange (ETDEWEB)

The ECOTEC combustion system and the architecture of the new Opel 2.2 l aluminum engine have been configured to achieve low noise and exhaust emissions. This power unit, employed in Germany for the first time in the Astra Coupe, already complies with the Euro IV emissions standard. It features minimum maintenance requirements and a long operating life. The DOHC spark-ignition engine with four valves per cylinder has two chain-driven camshafts, valve gear with roller cam followers and hydraulic lash adjusters. Two chain driven balancer shafts have been integrated into the engine block. The cylinder head and block, lower crankcase, oil pan, and cylinder head cover are all made of aluminum. A modular concept makes it possible to adapt the engine effectively to different vehicle concepts and markets. (orig.) [German] Das ECOTEC-Verbrennungssystem und die Motorarchitektur des neuen 2,2-l-Aluminium-Triebwerks von Opel sind auf niedrige Geraeusch- und ...

2000-09-01

265

Simulations of the design basis accident at conditions of power increase and the o transient of MSIV at overpressure conditions of the Laguna Verde Power Station; Simulaciones del accidente base de diseno a condiciones de aumento de potencia y del transitorio de cierre de MSIV a condiciones de sobrepresion de la Central Laguna Verde  

Energy Technology Data Exchange (ETDEWEB)

This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is concluded that the integrity of the containment is not challenged during a loss of coolant accident at ...

2001-07-01

266

Improved detection of myocardial infarction with technetium-99m stannous pyrophosphate and serum MB creatine phosphokinase  

International Nuclear Information System (INIS)

The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK activity. Serum MB CPK activity increased after cardiac surgery in 6 patients undergoing ...

267

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat pipe, in which the return of the condensate to the evaporator section is achieved by the movement of the heat pipe. The ...

2004-07-01

268

HT technology -- All-metal sealing answers safety and environmental concerns  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the ...

1995-12-31

269

Gas-diesel dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

A gas-diesel dual fuel engine apparatus is described having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including a gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine through the control of fuel supplied to the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode. The improvement of the governing and controlling device consists of: (a) at least one electronic governor means adapted to compare a speed signal representing the actual operating speed of the diesel engine with a set speed signal representing the set speed thereof; (b) a pair of electric actuator means having respective power amplifier circuits and mechanically connected to the diesel fuel injection pump and the gaseous fuel regulating valve, respectively, for the actuation thereof; (c) mode ...

1986-03-18

270

Electron-beam welding of valve bodies; Elektronenstrahlschweissen von Armaturengehaeusen  

Energy Technology Data Exchange (ETDEWEB)

In early March, 2000 a modern electron-beam welding facility for both series and one-off production of valves bodies (500 kg, up to 50 mm wall thickness) was commissioned at Josch Strahlschweisstechnik. Welding is performed under a fine vacuum. This permits not only the welding of components subject to acceptance inspection (HP0 approval), but also of special materials such as titanium, molybdenum, tungsten, Hastelloy and copper, and also their pairings. Products are developed and readied for production using modern 3D CAD software. A modern nine-axis control system makes it possible to produce sockets in pipe-on-pipe joints. (orig.) [German] Anfang Maerz 2000 wurde eine moderne Elektronenstrahlschweissanlage fuer die Herstellung von Armaturengehaeusen in Grossserien oder auch fuer Einzelfertigung (500 kg, bis 50 mm Wanddicke) bei der Josch Strahlschweisstechnik in Betrieb genommen. Die Schweissungen erfolgen im Feinvakuum. Somit koennen neben dem Schweissen ...

2000-03-01

271

A Human Reliability Analysis of Pre-Accident Human Errors in the Low Power and Shutdown PSA of the KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified pre-accident human ...

2003-04-20

272

Testing program for development of a high pressure, multi-product, fluid swivel  

Energy Technology Data Exchange (ETDEWEB)

This paper defines a rigorous seal test program conducted to develop a functional and proven high-pressure, multi-product swivel suitable for use as a Floating Production Storage and Offloading (FPSO) unit for the transfer of liquids and gases at high pressures and high temperatures through a rotating system. The test program was accomplished with specially designed test equipment with computer monitoring of temperature, torque, fluid pressures, seal lip temperatures, number of cycles, and leakage. The three primary phases are: (A) Seal Laterial screening with a computer-automated Falex testing machine, plus physical testing of chemically exposed samples. (B) One-third scale testing of several seal system configurations using a hydraulic driven, computer controlled test machine. (C) Full scale testing of prototype swivel. This paper documents the procedures for selection and testing of both the seal materials and the seal configuration. The test results clearly ...

1985-01-01

273

Status report on the development of a three-dimensional conceptual model for the Hanford Site unconfined aquifer system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the status of development of a three-dimensional conceptual model for the unconfined aquifer system at Hanford. A conceptual model is needed to support development of a realistic three-dimensional numerical model for predicting ground-water flow and the transport of contaminants. The report focuses on developing a hydrogeologic framework, assessing available hydraulic property data, describing flow-system boundaries, and evaluating areal recharge and leakage. Geologic descriptions of samples obtained during well drilling were used to prepare cross sections that correlate relatively continuous layers. The layers were defined based on textural differences that are expected to reflect differences in hydraulic properties. Assigning hydraulic properties to the layers is a critical part of the conceptual model. Available hydraulic property data for the study area were compiled and were correlated with the geologic layers where possible. Flow-system ...

1992-11-01

274

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet customers' needs. (author)

1999-12-01

275

Refinement and evaluation of crack-opening-area analyses for circumferential through-wall cracks in pipes  

Energy Technology Data Exchange (ETDEWEB)

Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet impingement shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. These leak rates depend on the crack-opening area of a through-wall crack in the pipe. In addition to LBB analyses, which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section 11. This study was requested by the NRC to review, evaluate, and refine current analytical models for crack-opening-area analyses of pipes with circumferential through-wall cracks. Twenty-five pipe ...

1995-04-01

276

Recent development in Mitsui B and W type gas injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A gas injection diesel engine was developed as an approaching measure to the diversification of fuel. Contrary to the usual low pressure gas application engine, this engine applies a so-called diffuse combustion method, in which high pressure (24.7Mpa) gas fuel is injected directly in the cylinder and is ignited and combusted by a little pilot fuel injected almost at the same time. The engine have following features. As a principle, it can attain the same heat efficiency and output rate as a diesel engine in any load range. It is excellent in responsibility to load fluctuation. There is no internal leakage of gas fuel to the scavenging chamber (the crank chamber) in the compression stroke. Not only a wide range of mixed combustion of gas fuel and heavy oil fuel, but also single combustion of heavy oil is possible. It is, therefore, drawing attention as an engine for an LNG ship and also for a power generation plant with the recent increasing demand of gas fuel ...

1988-12-01

277

Rationale for chemical control of feedwater and boiler water. Volume 1. Concentration models. Final report  

Science.gov (United States)

Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying out the base of the deposit. The pore to bulk concentration ...

1984-01-01

278

Radiation effects on MOS devices and radiation-hard CMOS technologies  

International Nuclear Information System (INIS)

Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. Experimental data taken for 2k-gate test chips indicate that radiation hardness of these ...

279

Prediction of the lifetime behaviour for C/C-SiC tubes as high and ultrahigh temperature heat exchangers (HITHEX) - material characterisation and qualification  

Energy Technology Data Exchange (ETDEWEB)

Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction between coating system and basic material was also investigated. Additionally a set of ...

2004-07-01

280

Posttest analysis of the FFTF inherent safety tests  

Energy Technology Data Exchange (ETDEWEB)

Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest analyses. The purpose of this paper is to present the results of the posttest ...

1987-01-01

281

Posttest analysis of the FFTF inherent safety tests  

International Nuclear Information System (INIS)

Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest analyses. The purpose of this paper is to present the results of the posttest ...

1987-06-07

282

Piping response testing associated with pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

EPRI has sponsored an experimental program in the pipe whip impact and pipe rupture and depressurization areas. Sixteen pipe whip tests were performed with 3 in Schedule 80 (or 10) carbon steel pipes impacting on rigid target or concrete slab. The major testing parameters include distance, impact location, pipe rupture location, and concrete slab thickness and strength. The piping crushing at impact correlates with impact force and target response behavior. Conservatism was established by comparing measured and calculated impact forces. The pipe rupture and depressurization tests were carried out using 6 in stainless steel and carbon steel pipes under either PWR or BWR fluid conditions. These tests are of axial crack with initial machined-in surface flaw. It was found that pipe rupture would occur only if a long unstable through-wall crack was embedded in a sufficiently long unstable part-through crack (in the pipe wall). All other flaw configuration tested led to pipe ...

1985-11-01

283

Overexpression of a maize dehydrin gene, ZmDHN2b, in tobacco enhances tolerance to low temperature  

British Library Electronic Table of Contents (United Kingdom)

Dehydrins, a subfamily of group 2 LEA proteins, are intrinsically unstructured plant proteins that accumulate in the late stages of seed development and in vegetative tissues subjected to water deficit, salinity, low temperature, or abscisic acid treatment. In this study, we isolated and characterized ZmDHN2b, a maize dehydrin gene. The genomic organization of the ZmDHN2b gene and its expression in maize seedlings were analyzed. To investigate the function of ZmDHN2b, we generated transgenic tobacco plants constitutively overexpressing ZmDHN2b. Ectopic expression of ZmDHN2b in tobacco accelerated seed germination and seedling growth at 15?C. Furthermore, ZmDHN2b-overexpressing lines had lower levels of cold-induced malondialdehyde and less electrolyte leakage than wild-type tobacco at 4?C....

2011-01-01

284

Oil-filled, multi-core cable with at least one conductor differing from others  

Energy Technology Data Exchange (ETDEWEB)

This patent discloses an oil-filled, multi-core, electric cable having three cores within a metal sheath suitable for underwater applications. Each core has a conductor surrounded by insulation and has substantially the same outer dimensions as the other cores. One conductor is made of copper and has a central oil duct. The other conductors are made of stranded aluminum wires in side-by-side and contacting relation and the ratio of the cross-sectional area of the metal of the copper conductor to the cross-sectional area of the metal of each aluminum conductor is the reciprocal of the ratio of the electrical conductivities thereof. One object of this invention is that of overcoming the drawbacks existing in the known oil-filled, multi-core cables, i.e. to provide cable which, in case of a rupture of the cable sheath, has fairly small leakages of insulating, fluid oil from the cable and at the same time permits a reduction in the weight of the cable for equal power ...

1987-02-03

285

New intelligent monitor for CANDU type NPP  

International Nuclear Information System (INIS)

Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy water leakage, (b) reduces the possibility of health hazard. In order to attain this goal of safety function, ...

2009-10-12

286

Modeling and evaluation of externally fired combined cycle using ASPEN  

Energy Technology Data Exchange (ETDEWEB)

A new performance model of the externally fired combined cycle (EFCC) is implemented in ASPEN (Advanced System for Process ENgineering), a chemical process simulator. The model accounts for interactions within and between approximately a dozen major process areas. The new model is applied to case studies to evaluate the sensitivity of process performance to the ranges of uncertainty in key model inputs such as heat losses, carbon conversion, and air leakage rates, and to illustrate how alternative designs, including steam injection and flue gas desulfurization (FGD), can affect plant thermal efficiency and net power output. The model results suggest that careful attention to the design of the FGD system is needed, especially with respect to reheat, and that steam injection may offer cost savings associated with reducing the size of the steam turbine with little or no penalty on plant output or plant efficiency. Uncertainties in the slagging combustor and the ...

1997-12-01

287

MONITORING POWER PLANT EFFICIENCY USING THE MICROWAVE-EXCITED PHOTOACOUSTIC EFFECT TO MEASURE UNBURNED CARBON  

Energy Technology Data Exchange (ETDEWEB)

Three test instruments are being evaluated to determine the feasibility of using photoacoustic technology for measuring unburned carbon in fly ash. The first test instrument is a single microwave frequency system previously constructed to measure photoacoustic signals in an off-line configuration. A second off-line instrument was constructed based in part on lessons learned with the first instrument, but which also expands the capabilities of the first instrument. Improvements include a control loop to allow more constant microwave power output and an ability to operate over a range of microwave frequencies. The third instrument, the on-line version of the fly ash monitor, has been designed, constructed, and initial efficiency tests have been conducted on the monitor's electrical components. This quarter focused on improving the signal strength of the accelerometer by increasing the power level of the microwaves that induced the thermo-elastic effect, and also to conduct ...

2004-07-01

288

Low-temperature radiation controlled diffusion of palladium and platinum in silicon for advanced lifetime control  

International Nuclear Information System (INIS)

Radiation defects produced by helium implantation were used to shape profiles of palladium (Pd) and platinum (Pt) atoms in-diffusing (for 20 min at temperatures 600-800 deg. C) either from surface silicide (Pd_2Si, PtSi) or implanted layers. Results show that this procedure allows a strong localization of substitutional Pd and Pt at the depth where the damage produced by helium peaks. This results in local reduction of carrier lifetime by an almost ideal recombination centers - the acceptor level of substitutional Pd (E _c - 0.22 eV) or Pt (E _c - 0.23 eV). While optimum conditions for Pt in-diffusion are about 700 deg. C, Pd gives the best results already at lower temperatures (600 deg. C) where it also exhibits higher peak solubility. Both methods were used for optimization of turn-off properties of high power PiN diodes. The devices, where the lifetime was killed locally by Pd and Pt, exhibited similar trade-off between the static and dynamic parameters as the diodes subjected to ...

2006-12-01

289

Low temperature formation of shallow p{sup +}n junctions by BF{sub 2}{sup +} implantation into thin Pd{sub 2}Si films on Si substrates  

Energy Technology Data Exchange (ETDEWEB)

Excellent silicided shallow p{sup +}n junctions have been successfully achieved by the implantation of BF{sub 2}{sup +} ions into thin Pd{sub 2}Si films on Si substrates to a dose of 5 {times} 10{sup 15} cm{sup {minus}2} and subsequent low temperature (even at 550 C) furnace annealing. The formed junctions have been characterized for respective implantation conditions. In this experiment, the implant energy is the key role in obtaining a low leakage diode. Reverse current density of about 3 nA/cm{sup 2} and an ideality factor of about 1.05 can be attained by the implantation of BF{sub 2}{sup +} ions at 80 keV and subsequent annealing at 550 C. The junction depth is about 0.09 {mu}m, measured by the spread resistance method. As compared with the results of unimplanted specimens, the implantation of BF{sub 2}{sup +} ions into a thin Pd{sub 2}Si layer can stabilize the silicide film and prevent it from forming islands during high temperature annealing.

1995-05-01

290

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate oxide tunneling ...

2006-08-15

291

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

International Nuclear Information System (INIS)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate oxide tunneling conduction ...

2006-08-01

292

Improved salt tolerance and seed cotton yield in cotton (Gossypium hirsutum L.) by transformation with betA gene for glycinebetaine synthesis  

British Library Electronic Table of Contents (United Kingdom)

Homozygous transgenic cotton (Gossypium hirsutum L.) plants that accumulated glycinebetaine (GB) in larger quantities were more tolerant to salt than wild-type (WT) plants. Four transgenic lines, namely 1, 3, 4, and 5, accumulated significantly higher levels of GB than WT plants did both before and after salt stress. At 175 and 275?mM NaCl, seeds of all the transgenic lines germinated earlier and recorded a higher final germination percentage, and the seedlings grew better, than those of the WT. Under salt stress, all the lines showed some characteristic features of salt tolerance, such as higher leaf relative water content (RWC), higher photosynthesis, better osmotic adjustment (OA), lower percentage of ion leakage, and lower peroxidation of the lipid membrane. Levels of endogenous GB in ...

2011-01-01

293

High tunability of pulsed laser deposited Ba0.7Sr0.3TiO3 thin films on perovskite oxide electrode  

British Library Electronic Table of Contents (United Kingdom)

Ferroelectric thin films such as BST, PZT and PLZT are extensively being studied for the fabrication of DRAMS since they have high dielectric constant. The large and reversible remnant polarization of these materials makes it attractive for nonvolatile ferroelectric RAM application. In this paper we report the characterization of Ba0.7Sr0.3TiO3 (BST) thin films grown by pulsed laser ablation on oxide electrodes. The structural and electrical properties of the fabricated devices were studied. Growth of crystalline BST films was observed on La0.5Sr0.5CoO3 (LSCO) thin film electrodes at relatively low substrate temperature compared to BST grown on PtSi substrates. Electrical characterization was carried out by fabricating PtSi/LSCO/BST/LSCO heterostructures. The leakage current of the heteros...

2011-01-01

294

GaInP high-power lasers; GaInP Hochleistungslaser  

Energy Technology Data Exchange (ETDEWEB)

The following work deals with the realization, characterization and modeling of GaInP / AlGaInP high power semiconductor laser diodes in the visible wavelength range. In addition to the exploration and optimization of efficiency, temperature stability and maximum output power of multi-mode lasers especially methods for longitudinal and lateral mode stabilization of high power laser diodes have been investigated. Although often the focus of optimization is on the threshold current density, in this work the performance of the laser diode for an operation point around 1 Watt under continous wave operation is regarded as the figure of merit. It turns out that low carrier densities are key for an efficient reduction of the heterobarrier leakage currents. In addition, large optical cavity structures with low internal losses enable high external quantum efficiencies even for long cavities. Finally high laser effiency as well as an efficient cooling leads to a reduced ...

2002-07-01

295

GaInP high-power lasers  

International Nuclear Information System (INIS)

The following work deals with the realization, characterization and modeling of GaInP / AlGaInP high power semiconductor laser diodes in the visible wavelength range. In addition to the exploration and optimization of efficiency, temperature stability and maximum output power of multi-mode lasers especially methods for longitudinal and lateral mode stabilization of high power laser diodes have been investigated. Although often the focus of optimization is on the threshold current density, in this work the performance of the laser diode for an operation point around 1 Watt under continous wave operation is regarded as the figure of merit. It turns out that low carrier densities are key for an efficient reduction of the heterobarrier leakage currents. In addition, large optical cavity structures with low internal losses enable high external quantum efficiencies even for long cavities. Finally high laser effiency as well as an efficient cooling leads to a reduced ...

296

Fusion power and the environment  

Science.gov (United States)

Environmental characteristics of conceptual fusion-reactor systems based on magnetic confinement are examined quantitatively, and some comparisons with fission systems are made. Fusion, like all other energy sources, will not be completely free of environmental liabilities, but the most obvious of these-- tritium leakage and activation of structural materials by neutron bombardment-- are susceptible to significant reduction by ingenuity in choice of materials and design. Large fusion reactors can probably be designed so that worst-case releases of radioactivity owing to accident or sabotage would produce no prompt fatalities in the public. A world energy economy relying heavily on fusion could make heavy demands on scarce nonfuel materials, a topic deserving further attention. Fusion's potential environmental advantages are not entirely ''automatic'', converting them into practical reality will ...

1975-06-01

297

Experimental electrochemical capacitor test results  

Energy Technology Data Exchange (ETDEWEB)

Various electrochemical capacitors (ultracapacitors) are being developed for hybrid vehicles as candidate power assist devices for the fast response engine. The primary functions of the ultracapacitor are to level the dynamic power loads on the primary propulsion device and recover available energy from regenerative breaking during off-peak power periods. Ultracapacitors show promise toward being able to accept high regenerative pulses while exhibiting very high cycle life. This paper will present test data from selected US Department of Energy (DOE) supported ultracapacitor projects designed to meet the fast response engine requirements. Devices containing carbon, conducting polymers, and metal oxide electrode materials in combination with aqueous or organic electrolytes are being supported by the DOE. This paper will present and discuss testing data obtained from recent prototype capacitors supplied by Maxwell Energy Products, Inc., SAFT America, Inc., Federal Fabrics-Fibers and the ...

1997-11-01

298

Evaluation of a solid hydrophone cable  

Energy Technology Data Exchange (ETDEWEB)

In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage causes buoyancy loss and the need for immediate replacement. Salt water intrusion causes electrical shorts. Replacement rates ...

1982-07-01

299

Equivalent magnetic noise in magnetoelectric Metglas/Pb(Mg1/3Nb2/3)O3-PbTiO3 laminate composites  

British Library Electronic Table of Contents (United Kingdom)

Abstract We have experimentally and theoretically investigated the equivalent magnetic noise in a magnetoelectric Metglas/ 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 laminate sensor unit by considering the constituent noise sources of dielectric loss (NDE) and DC leakage resistance (NR). In the low frequency range (f = 1 Hz), theory predicts that NR dominates the noise charge (1.6 times larger than NDE), with a 1 Hz noise of 9.1\\;{\\rm pt}/\\sqrt {\\rm Hz}. The experimental equivalent magnetic noise was 10.8\\;{\\rm pt}/\\sqrt {\\rm Hz}. This observed value is slightly higher than the predicted one, which might be due to an oversimplification of the theoretical model in terms of electrical charge amplifier and external vibration noise sources. ( 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2011-01-01

300

Electrochemical sulfur passivation of visible ([similar to]670 nm) AlGaInP lasers  

Science.gov (United States)

III--V based devices such as field effect transistors, heterojunction bipolar transistors, and lasers often have surface leakage and thermal degradation problems due to surface states which pin the Fermi level to the midgap. Sulfur based passivation processes are known to improve device performance by altering surface-state densities. We have developed a voltage-controlled anodic sulfur passivation scheme using Na[sub 2]S dissolved in ethylene glycol. Our process has repeatedly produced a [similar to]25% improvement in peak output power near the catastrophic damage limit in visible ([lambda]=670 nm) AlGaInP edge-emitting lasers. The threshold current density before and after passivation, and the [ital I]--[ital V] characteristics before and after catastrophic failure, were essentially unchanged indicating that passivation raises the threshold for facet damage.

1994-07-01

301

Electrochemical sulfur passivation of visible (#approx#670 nm) AlGaInP lasers  

International Nuclear Information System (INIS)

III--V based devices such as field effect transistors, heterojunction bipolar transistors, and lasers often have surface leakage and thermal degradation problems due to surface states which pin the Fermi level to the midgap. Sulfur based passivation processes are known to improve device performance by altering surface-state densities. We have developed a voltage-controlled anodic sulfur passivation scheme using Na_2S dissolved in ethylene glycol. Our process has repeatedly produced a #approx#25% improvement in peak output power near the catastrophic damage limit in visible (#lambda#=670 nm) AlGaInP edge-emitting lasers. The threshold current density before and after passivation, and the I--V characteristics before and after catastrophic failure, were essentially unchanged indicating that passivation raises the threshold for facet damage.

302

Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications  

Science.gov (United States)

Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS device applications.

2004-09-01

303

Drop Test of the Candu Spent Fuel Storage Basket in MACSTOR/KN-400  

International Nuclear Information System (INIS)

The MACSTOR/KN-400 of Wolsung power plant in Korea is a dry interim storage facilities. There are 400 long slender cylinders in MACSTOR/KN-400. In one cylinder, ten baskets where Candu spent fuels are loaded are stacked and stored. For this MACSTOR/KN-400 facilities, analyses and tests for the hypothetical accident conditions that might happen during moving and storing baskets into a cylinder were performed. The hypothetical accident conditions to be considered are two cases. One is the case of basket dropping onto the bottom plate of a cylinder. The other is the case of basket dropping onto the other basket top plate stored in the cylinder. For the drop analyses, the case of hanging cylinder and the case of cylinder on the unyielding target surface were considered. Based on the dropping analysis, testing condition was determined as the latter case that is for the cylinder on the target surface. In a basket, 60 dummy fuel bundles are loaded which have the same weight of real spent fuel ...

2009-06-01

304

Diverter system test tool and method  

Energy Technology Data Exchange (ETDEWEB)

A method is described for testing a diverter system on an offshore drilling rig of a type having a marine riser assembly extending to a subsea well, the diverter system having a packer element and at least one port located below the packer element for the passage of drilling fluid flowing upward from the marine riser assembly during drilling. The method consists of connecting a tubular member to the upper end of a packer having an elastomeric expansive seal element; placing the packer in an upper portion of the marine riser assembly below the diverter system and expanding the seal element against the interior of the upper portion; closing the packer element of the diverter system around the tubular member; and finally applying fluid pressure in the space between the packer element of the diverter system and the seal element of the packer to determine if any leakage in the diverter system exists. The patent also describes an offshore drilling rig linked to a subsea ...

1989-04-04

305

Development of production methods of volume source by the resinous solution which has hardening  

CERN Document Server

Volume sources is used for standard sources by radioactive measurement using Ge semiconductor detector of environmental sample, e.g. water, soil and etc. that require large volume. The commercial volume source used in measurement of the water sample is made of agar-agar, and that used in measurement of the soil sample is made of alumina powder. When the plastic receptacles of this two kinds of volume sources were damaged, the leakage contents cause contamination. Moreover, if hermetically sealing performance of volume source made of agar-agar fell, volume decrease due to an evaporation off moisture gives an error to radioactive measurement. Therefore, we developed the two type methods using unsaturated polyester resin, vinilester resin, their hardening agent and acrylicresin. The first type is due to dispersing the hydrochloric acid solution included the radioisotopes uniformly in each resin and hardening the resin. The second is due to dispersing the alumina ...

2002-01-01

306

Development and field application of a leak sealant for the NRU water reflector  

International Nuclear Information System (INIS)

The development and successful application of a unique leak sealant formulation comprised of a mixture of graded, hollow ceramic microspheres, surface oxidized aluminum powder and saturated gibbsite suspension is described. The project was undertaken to address the escalating leakage from up to 15 small weld defects in the water reflector vessel, an integral component of the NRU (National Research Universal) reactor calandria. The reflector surrounds the reactor core with a neutron reflecting blanket of light water. Injection of the sealant is typically done with the reactor shutdown and the water reflector system operating normally, but can also be performed with the reactor at full power. The procedure is simple and effective. Individual treatments of as little as 125 ml of sealant (10 ppm in the 12,500 L system) have yielded leak reductions exceeding 2000 L/day. The accumulated leak reductions of several treatments now total 90% of the historic high of 5,400 ...

2001-06-10

307

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a transconductance of ...

2002-01-01

308

Crud removal performance with ion exchange resins in BWR plants  

Energy Technology Data Exchange (ETDEWEB)

It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud removal. The results from column tests using actual condensate water for approximately ...

1996-01-01

309

Carbon steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to considerable investigation of the mechanism of corrosion and for palliatives. The basic mechanism is now fairly well understood. Chloride present in the boiler feedwater from condenser leakage is concentrated in the support plate crevice as a result of the superheat present. This leads to the formation of a low pH acid ferrous chloride environment either through the hydrolysis of a weak base chloride such as MgCl_2 or the combined action of a neutral chloride with an oxidizing agent. Rapid attack of the carbon steel ensues with the Fe_3O_4 corrosion product forming at the metal/oxide interface. This oxide has a volume approximately twice that of the steel consumed and thus eventually fills the crevice between the tube and the support plate. Oxide growth continues leading to compression of the Alloy 600 primary tube and to distortion and ...

1985-03-01

310

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. In this way, the plant's computer ...

1986-01-01

311

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat exchanger is not impeded. Particularly the ...

2003-08-17

312

Application of LBB to high energy pipings of PWR in Korea  

Energy Technology Data Exchange (ETDEWEB)

The application of the LBB technology to the newly constructed PWRs has been approved in Korea for several high energy systems that can meet rigorous acceptance criteria. The LBB evaluation had been initiated for Yong-Gwang 3 and 4 units (YGN 3 and 4) which are in service, and subsequently performed for Ul-Chin 3 and 4 units (UCN 3 and 4) which are in construction. The LBB application in Korea is based on the USNRC requirements. The LBB evaluation for YGN 3 and 4 is to eliminate the dynamic effects associated with the postulated DEGB from design basis loads as well as to eliminate pipe whip restraints and jet impingement barriers. There were several issues on the application of LBB to the primary coolant loop and the pressurizer surge line. Of concern were material properties of carbon steel for the primary coolant loop, estimation of crack opening area at the pipe-to-nozzle interface considering the asymmetry, and the leakage crack size which barely meets the ...

1996-12-31

313

All-metal divided vaccum joints with small force of sealing  

International Nuclear Information System (INIS)

The structure of a demountable vacuum joint designed for operation from -120 to +120 deg C is developed and tested. Requirements of especially low gas release from the materials used have been fulfilled; the same concerns low sealing efforts, repeated action and keeping tightness under loads, indium being used as a sealant. Experimental studies of demountable vacuum joints, dia 100,125,140,160,180 and 200 mm, with an indium sealant permit to make the following conclusions: 1. The joints are sealed at sealing specific efforts of 0.4 kg/mm (without considering atmospheric pressure). 2. The joints retain tightness at opening and closing a cover five times and under +-120 deg C. 3. To ensure repeated operation of the joint with continued stable sealing effort, one should make sure the sealed surfaces coincide at repeated sealing. 4. When operating demountable vaccum joints with indium sealant, one must take into account the time factor, since time dependence of leakage ...

314

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM ...

1998-12-01

315

Leakage currrent characteristics and dielectric breakdown of antiferroelectric Pb{sub 0.92}La{sub 0.08}Zr{sub 0.95}Ti{sub 0.05}O{sub 3} film capacitors grown on metal foils.  

Science.gov (United States)

We have grown crack-free antiferroelectric (AFE) Pb{sub 0.92}La{sub 0.08}Zr{sub 0.95}Ti{sub 0.05}O{sub 3} (PLZT) films on nickel foils by chemical solution deposition. To eliminate the parasitic effect caused by the formation of a low-permittivity interfacial oxide, we applied a conductive buffer layer of lanthanum nickel oxide (LNO) on the nickel foil by chemical solution deposition prior to the PLZT deposition. Use of the LNO buffer allowed high-quality film-on-foil capacitors to be prepared at high temperatures in air. With the AFE PLZT deposited on LNO-buffered Ni foils, we observed field-induced phase transformations of AFE to ferroelectric (FE). The AFE-to-FE phase transition field, E{sub AF} = 260 kV cm{sup -1}, and the reverse phase transition field, E{sub FA} = 220 kV cm{sup -1}, were measured at room temperature on a {approx}1.15 {micro}m thick PLZT film grown on LNO-buffered Ni foils. The relative permittivities of the AFE and FE states were {approx}530 and {approx}740, ...

2008-01-01

316

Fatty acid/poly(methyl methacrylate) (PMMA) blends as form-stable phase change materials for latent heat thermal energy storage  

Energy Technology Data Exchange (ETDEWEB)

Fatty acids such as stearic acid (SA), palmitic acid (PA), myristic acid (MA), and lauric acid (LA) are promising phase change materials (PCMs) for latent heat thermal energy storage (LHTES) applications, but high cost is the most drawback which limits the utility area of them in thermal energy storage. The use of fatty acids as form-stable PCM will increase their feasibilities in practical LHTES applications due to reduced cost of the energy storage system. In this regard, a series of fatty acid/poly(methyl methacrylate) (PMMA) blends, SA/PMMA, PA/PMMA, MA/PMMA, and LA/PMMA were prepared as new kinds of form-stable PCMs by encapsulation of fatty acids into PMMA which acts as supporting material. The blends were prepared at different mass fractions of fatty acids (50, 60, 70, 80, and 90% w/w) to reach maximum encapsulation ratio. All blends were subjected to leakage test by heating the blends over the melting temperature of the PCM. The blends that do not allow ...

2008-02-15

317

Wall quench and flammability limit effects on exhaust hydrocarbon emission. Final technical report, Phase 8, March 1, 1983-February 28, 1984  

Energy Technology Data Exchange (ETDEWEB)

This report documents the concluding efforts at the Engineering Sciences Laboratory of TRW on two specific areas of current research activity within the more general context of proposed lean-burn operation of Otto-cycle-type automotive engines. These areas are: (1) achievement of knock-free performance, both under available fuels and current compression ratios and also under higher-octane fuels (e.g., alcohols) and higher-compression-ratio design (for greater thermal efficiency); and (2) identification of counterstrategies for two-wall (crevice-type) quenching of flame propagation, a phenomenon now widely acknowledged to be the major source of unburned-hydrocarbon emissions exhausted from homogeneous-charge cyclinders. There are certainly other highly active areas of research in Otto-cycle engines, such as turbocharging, ignition devices, and valve design, but the two above-cited topics were the topics of this project.

1984-01-01

318

Visualization and measurement of pressurized multiphase flow using neutron radiography of JRR-3M system  

Energy Technology Data Exchange (ETDEWEB)

Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in ...

1998-01-01

319

Utilization of emulsified rapeseed oil in a direct injection diesel engine; Chokufunshiki diesel kikan deno nataneyu nyuka nenryo no riyo  

Energy Technology Data Exchange (ETDEWEB)

With an objective to use reproducible vegetable oil as a substitute fuel, studies were performed to use emulsified rapeseed oil at an optimal mixing ratio with water in a direct injection diesel engine. The experiment used a water cooled, lateral installation, single-cylinder, direct injection, four-cycle diesel engine, and the tested fuel used an emulsified rapeseed oil fuel with rapeseed oil added with water at a rate of 20% by weight. As a result of the experiment using the emulsified rapeseed oil, it was found that reducing the injection opening diameter smaller than the standard opening diameter improves the engine performance and simultaneously reduces concentrations of HC, CO and exhaust smoke. The optimal opening diameter was about 0.22 mm. Increasing the valve opening pressure reduced the NOx concentration, but increased the HC concentration. Using the emulsified rapeseed oil fuel accumulated more carbon below the head, but much smaller amount on the ...

1994-09-30

320

Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to ...

2008-11-15

321

The year 2000 embedded systems problem to maintain the safety of nuclear installations  

International Nuclear Information System (INIS)

The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a valve, may control the flow of cooling system to reactor core. Embedded systems in our organization are also be found in Batan ...

1999-02-01

322

The effects of Al{sub 2}O{sub 3}-TiO{sub 2} coating in a diesel engine on performance and emission of corn oil methyl ester  

Energy Technology Data Exchange (ETDEWEB)

Today, as a result of increase in oil prices, limited fossil fuel resources, environmental consideration and global warming, the methyl ester fuels have been focused on alternative fuels. Methyl ester fuels can be used more efficiently in low heat rejection engines (LHR), in which the temperature of combustion chamber is increased by creating a thermal barrier. In this study, the piston, cylinder head, exhaust and inlet valves of a diesel engine were coated with the ceramic material Al{sub 2}O{sub 3}-TiO{sub 2} by the plasma spray method. Thus, a thermal barrier was provided for the parts of the combustion chamber with these coatings. The effects of corn oil methyl ester that produced by the transesterification method, and No. D2 fuels' performance and exhaust emissions' rate were studied by using equal in every respect coated and uncoated engines. Tests were performed on the uncoated engine, and then repeated on the coated engine and the results ...

2010-10-15

323

The French design code: RCC-M status and on-going developments  

International Nuclear Information System (INIS)

Since 1978, an important effort has been on-going between Framatome and Electricite de France (EDF) to develop and update technical rules for the design and construction of nuclear power plants. Two design codes are developed, one for PWRs: RCC-M and one for FBRs: RCC-MR. After some comments on the organization of RCCM Commission, the paper presents: (1) the major differences with the ASME Section III Code for fatigue, plastic shakedown and rupture analysis; (2) the review of some important facts in terms of availability or maintenance costs (in-service inspection, replacements, repairs, etc.) of operating plants like underclad cracking, stratification, CRDM nozzles, cast elbows, steam generator tubes, etc.; (3) how can one take into consideration this operating feedback in RCC-M Code; and (4) few examples of major on-going developments for fracture analysis on different components and fatigue analysis of valves. In conclusion, the standardization of the plants is ...

1996-07-21

324

Study on the application of a geothermal heat pump; Etude sur l`application d`une pompe a chaleur geothermique  

Energy Technology Data Exchange (ETDEWEB)

The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, which is very low compared to the consumption of electric heating (0.286 GJ per sq.m) or oil heating (0.419 GJ per sq.m). 4 figs., 1 tab.

1996-12-01

325

Simulation for transient stability study of the Taiwan power system - a nuclear majority system  

Energy Technology Data Exchange (ETDEWEB)

A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional four functions: load-limit operation simulated by a low-value ...

1984-01-01

326

Simulation for transient stability study of the Taiwan power system - a nuclear majority system  

International Nuclear Information System (INIS)

A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional four functions: load-limit operation simulated by a low-value ...

327

Sealing of nuclear plant electrical equipment: Final report  

International Nuclear Information System (INIS)

The nuclear power industry has many applications where electrical equipment is required to operate in environments which contain high relative humidity, steam and water or chemical sprays. Equipment is susceptible to these environments by moisture entering through inherent design provisions such as O-rings and through the electrical interface. The objective of this research is to review electrical interface sealing techniques and to recommend methods for providing effective electrical interface sealing. The most common methods of sealing are the use of electrical fittings containing sealants, add-on assemblies and hardware changeout. The experience gained in several years of testing electrical interface seals on such devices as limit switches, solenoid valves and transmitters is presented to provide information on seal effectiveness and preferred application. The effectiveness of various sealing methods is discussed, each of which is dependent upon the device being ...

328

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of radiation dose equivalent based ...

1990-03-01

329

Reliability analysis for stiff versus flexible piping  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. We then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. We concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of supports and snubbers without violating ASME code requirements. Furthermore, the more flexible piping redesigns are capable of exhibiting reliability levels equal to or higher than the original stiffer design. An ...

1985-11-01

330

Reduction of nitrogen oxides (NO{sub x}) production in a liquid fuel-oil diffusion flame by acoustic excitation; Reduction de la production des oxydes d`azote (NO{sub x}) dans une flamme de diffusion a fioul liquide par excitation acoustique  

Energy Technology Data Exchange (ETDEWEB)

The control of nitrogen oxides (NO{sub x}) emissions will become a major challenge in the forthcoming years, in the domain of automotive industry or industrial burners. Pulsed combustion offers an imaginative solution which does not affect the combustion efficiency. In this paper, the efficiency of this method is demonstrated using the burner of a 20 kW domestic boiler. The actuator is simply installed on the air intake. Two types of actuators have been tested successfully: a loudspeaker and a rotative valve. Both can produce 100 to 1000 Hz frequencies and can lead to a reduction of 20% of NO{sub x} emissions. The feasibility of the concept is also demonstrated on a 840 kW liquid fuel-oil burner. The mechanisms involved during an excitation are explained using the CH{sup *} radical imaging. Results show an important reorganization of the flow and of the flame structure. During each excitation cycle, an annular swirl occurs at the leading edge of the flame catching ...

1996-12-31

331

Recent increased use of polybutylene terephthalate (PBT) resin in automotive field. Jidosha bun prime ya de kinnen kakudai shimesu PBT jushi  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation grade is wanted. Valves for exhaust control require high-temperature rigidity, ...

1992-06-18

332

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

333

Preliminary Guideline for the High Temperature Structure Integrity Assessment Procedure Part I. High Temperature Structure Design Guide  

Energy Technology Data Exchange (ETDEWEB)

A preliminary guideline for the design and evaluation of LMR high temperature structure is presented based upon ASME B and PV Code, Section III, Subsection NH. The main contents of this guideline are the materials, general design, vessel, piping, core support structure, pumps, valves, fabrication, examination, and testing for the class 1 components. The ratcheting evaluation, enhanced creep assessment, welds design and evaluation, inelastic analysis approach, piping design alternatives, and bellows design method are described in appendices. A user of this guideline should follow the essential procedures and may refer to other pertinent codes, standards, laws, regulations, or other pertinent documents when this guideline does not lead to proper design of the structure. While this guideline adopts major procedures of Subsection NH, it refers to the RCC-MR and/or DDS in some amount for the items where these codes have excellency to improve this guideline.

2007-02-15

334

Methane gas engine  

Energy Technology Data Exchange (ETDEWEB)

The fuel-injection system of the Niigata 6L 16X-AG dual-fuel engine is structured to steadily supply injected fuel during diesel-engine operation, and to distribute oil at a low rate to all the cylinders during gas-engine operation. The dual-fuel engine is started by the diesel engine operation and is changed over to gas-engine operation when the load increases. This change over is done automatically with a link mechanism. Regarding the gas-supply system, the changing pressure of supply gas is controlled by a pressure control valve which is stable and most adequate for the engine. The dual-fuel engine has the following features: (1) a high compression ratio is adopted, which reduces fuel consumption and thermal efficiently; (2) if the supply of gas decreases or stops, while continuing loaded operations, it can immediately shift to diesel engine operation automatically and continue the operation; (3) ignition is done by the injection of pilot oil, thus eliminating ...

1980-01-01

335

Metallic implants and exposure to radiofrequency radiation  

International Nuclear Information System (INIS)

There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in ...

336

Measurement of swirling flow in direct injection diesel engine (Part 2). Effect of piston cavity diameter and top clearance volume  

Energy Technology Data Exchange (ETDEWEB)

Swirling flow in a direct injection diesel engine was measured by a laser doppler velocimeter. Piston cavity diameter and top clearance volume were changed as factors affecting swirling flow to study the distribution of swirling flow speed. When using the same intake port and changing the opening ratio of piston cavity, the distribution of swirling flow speed was different by the cavity during intake process but these agree just after opening intake valve and then become again different by cavity. When increasing top clearance and decreasing compression ratio, the axial symmetry of flow during commpression process increases. When changing piston cavity, and also when changing intake port, the mean swirling ratio in inside and outside areas of combustion chamber has common tendency to increase and decrease respectively. The mean swirling flow in the combustion chamber may be capable to be predicted by devising a model which can describe this tendency. 3 refs., 9 ...

1989-05-31

337

Measurement of swirling flow in direct injection diesel engine (Part 1). Effect of intake port geometry and engine speed  

Energy Technology Data Exchange (ETDEWEB)

Swirling speed in a direct injection diesel engine was measured by a laser doppler velocimeter. Intake port geometry and engine speed were changed as factors affecting the swirling flow to study the distribution of swirling flow speed. The distribution of swirling flow speed changes complicatedly owing to axial nonsymmetry during intake process but becomes simple shape of axial symmetry during compression process after closing intake valve. But if this is assumed as the rigid swirl shape, the difference due to each intake port cannot be expressed but also large error may be possible to appear close to the cylinder wall. The distribution of swirling flow speed during compression process changes similarly, nearly proportinal to engine speed. But the similarity is higher at the middle period in compression process than at the end period in compression period. Axial distribution of local swirling ratio during compression process is nearly uniform. 8 refs., 10 figs., 1 ...

1989-05-31

338

Management and optimization of the CPCU network working  

Energy Technology Data Exchange (ETDEWEB)

The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for the establishing management data in real time. For the water, the system forecasts the ...

1991-10-01

339

Loss of flow incident - Simulation and measurements in the MPR  

International Nuclear Information System (INIS)

As part of the Probabilistic Safety Analysis of the Multi Purpose Reactor, MPR, the list of Postulated Initiating Events was analyzed and one of these PIEs corresponds to the Loss of Coolant Flow. It is well known that during the operation life of a research reactor a LOFA could eventually occur and, once this event takes place, in time detection and automatic actions, thanks to the engineering safety features of the system, will mitigate the incident evolution. The postulated event corresponds to a loss of flow due to a total loss of power supply. The goal of the present work is to provide a general description and the engineering safety features of the MPR, as well as describe the sequence of scenarios during a LOFA. Temporal evolution of main parameters is presented, also. During Stage A of the Commissioning Program measurements of the core cooling system pump coast-down were performed in order to validate previous simulation results, as well as, flap valves ...

1999-10-26

340

Ion exchange at TNX using the SKID unit  

Energy Technology Data Exchange (ETDEWEB)

An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination factor (DF) will be measured for a non-radioactive, simulated, ...

1993-10-21

341

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by BSC and DSO and will not be placed until ...

1990-09-10

342

Higher order time-frequency analysis as a tool for health monitoring  

Energy Technology Data Exchange (ETDEWEB)

In machine condition monitoring many fault-related vibration signals are highly non-stationary. Time-frequency representations comprise the natural signal-processing tool traditionally used for representing such non-stationary signals. The methods used in this analysis are based on the second order statistics of a signal. This paper discusses the use of higher order time frequency methods in the context of a condition monitoring application. The paper outlines the two classes of higher order representations: the L-Wigner distribution and the sliced Wigner higher order distribution. The use of higher order distributions introduces the possibility of non-oscillating cross-terms, a problem not encountered in conventional bilinear time-frequency methods. Techniques for reducing these cross-terms are presented. The paper compares the performance of bilinear and higher order time-frequency methods using synthetic data and vibration signals measured on the engine block of the passenger car ...

2003-07-01

343

HC cylinder to cylinder deviation at idling condition in a direct injection diesel engine. Chokusetsu funshashiki diesel kikan mufuka untenji no HC kitokan hendo  

Energy Technology Data Exchange (ETDEWEB)

Causes of variation of hydrocarbon (HC) concentration in cylinder to cylinder at idling condition in a direct injection diesel engine were studied. The ratio of l/d=6 gives larger HC variation in cylinder to cylinder than the l/d=2, where l means the nozzle hole length and d means the nozzle hole diameter. This is because the condition of l/d=6 can result in the large spray penetration and increase the fuel on the combustion chamber. The spray structure changes between nozzles and also changes between nozzle holes. This is not caused by the shape of nozzle hole but is affected by the pressure change near the inlet of nozzle hole when the needle valve is lifted. The change of spray structure can change the injection volume between nozzle holes. The injection volume is less for a nozzle hole where the curved angle becomes sharp to the nozzle central angle, and is more at the opposite side. When the injection volume of the nozzle hole near the chamber wall increases, ...

1992-07-01

344

GRI's Gas Appliance Technology Center: 1989 annual report, February 1989-April 1990 (Activity at Battelle)  

Science.gov (United States)

The goal of GRI's Gas Appliance Technology Center is to encourage the introduction of highly efficient, cost-effective, convenient gas appliances for residential and commercial gas users. The report covers activity at Battelle from February 1989 to April 1990 in broad support tasks, residential and commercial appliances, and residential space conditioning. Broad support tasks included the G/A/S Newsletter; the GATC InfoBase; and technology transfer, workshops, and GATC coordination. Residential appliance tasks included burner technology research, gas appliance venting, gas lighting, and plastics durability. Commercial appliance tasks included development of a commercial cooktop fuel/air mixing valve. Residential space conditioning tasks included a corrosion test method for gas appliances and vents, generic technology for condensing heat exchangers, and technology for self-powered appliances. These tasks are described briefly, with references to reports and ...

1990-12-01

345

Fast diagnosis and treatment of crack-like defect injuriousness in nuclear power plant equipment  

Energy Technology Data Exchange (ETDEWEB)

Increasingly stringent safety requirements governing the nuclear industry have made it essential to gain in-depth knowledge of the injuriousness of cracking phenomena in auxiliary and secondary nuclear power plant systems, and to devise methods of rapidly evaluating potentially injurious flaws. The Defect Injuriousness Diagnosis and Treatment Package (DIDTP) discussed in this paper was developed by Framatome, a French-based PWR builder, with this goal in mind. A general description is given of the DIDTP, which is made up of tables and nomographs illustrating the injuriousness of flaws liable to be encountered in the most severely loaded regions of plant systems. The basic principles underlying the DIDTP, together with computational methods and application procedure, are detailed. Two practical examples illustrating the use of the diagnostic system are presented, one applied to the main steam line, the other to gate valve wedges. The types of results obtained and ...

1985-01-01

346

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel: In natural convection dominated flow regimes  

British Library Electronic Table of Contents (United Kingdom)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated in the natural convection dominated region for a wide range of Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.02win0.025m/s) using a flow rate control valve so that Reynolds number was always about ...

2009-01-01

347

Evaluation of spark ignition of a gas cooktop flame  

Science.gov (United States)

One of the energy-saving devices used on gas cooking appliances to eliminate the standing pilot is a spark ignition system. For safety, an ignition system must start promptly and be active whenever flowing gas is not ignited. To minimize noise and nuisance shock hazard, ignition must occur quickly and the sparking must be stopped as soon as ignition occurs and remain off as long as the flame is present. To accomplish both of these requirements, ignition systems have been devised which use the electrical current rectification property of a flame to sense it. These systems spark whenever the gas valve is on and a flame is not present. The factors affecting the performance of a spark ignition system are numerous, complex, and transient. All of these properties make quantification of performance difficult. A system is described which can evaluate the overall performance of ignition systems over significant periods of time and varieties of operating conditions and ...

1996-01-01

348

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, loss of the GDCS pool water is prevented and ...

1990-10-29

349

Electronic fuel injection techniques for hydrogen powered i. c. engines  

Energy Technology Data Exchange (ETDEWEB)

Numerous studies have demonstrated the advantages of hydrogen as a fuel for Otto Cycle engines due to high thermal efficiency and low exhaust pollutant levels. Characteristic of hydrogen engine operation using premixed intake charge formation is a problem of pre-ignition resulting in an intake manifold backfire. Additional problems include high NO production when using certain equivalence ratios and power output degradation due to low fuel energy/volume density. Techniques for direct and port fuel injection are discussed as means for overcoming these problems. Emphasis is placed on the need for total engine control, integrating control of fuel injection, ignition timing, intake air throttling, and vehicle subsystems within a central electronic unit. An electronically actuated fuel injection valve and a prototype electronic control system are developed. These are applied in port and direct injection system geometries, and evaluated in engine testing. System ...

1980-01-01

350

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a ...

351

Device for controlling water supply to nuclear reactor  

International Nuclear Information System (INIS)

Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator generating signals for indicating whether one or two water supply pumps are operated. A low value preferential circuit passes the lower of the values generated from the ...

352

Development of a 1200 KW/CYL low pressure dual fuel engine for LNG carriers  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant fouling of the combustion chamber is still ...

1998-12-31

353

Characterization and nanopatterning of Ni{sub 2}MnIn Heusler films  

Energy Technology Data Exchange (ETDEWEB)

The Heusler alloy Ni{sub 2}MnIn is a promising material as spin injector because of its predicted half-metallicity at the interface to InAs. We grow thin films of this Heusler alloy by thermal coevaporation of Nickel and the alloy MnIn. The alloy is grown on Si{sub 3}N{sub 4} membranes and amorphous carbon films for transmission-electron microscopy (TEM) as well as on Si and InAs. The degree of the transport spin polarization of the films grown on Si(100), InAs(100) and in-situ cleaved (110) surfaces of InAs is determined by point-contact Andreev reflection spectroscopy (PCAR). The almost perfect lattice match between InAs and Ni{sub 2}MnIn supports highly oriented growth, as we have proven by electron diffraction under grazing incidence. Lateral spin valves with Heusler electrodes are lithographically defined. In view of the temperature-sensitivity of the optical and electron-beam resists, the samples are grown at substrate temperatures of 50 C and annealed up to ...

2008-07-01

354

Brazilian onshore pipelines rehabilitation program  

Energy Technology Data Exchange (ETDEWEB)

Brazil currently has an oil and transport system with approximately 15,000 km of pipeline. However, energy needs are now increasing due to rapid population growth and expanding industrial activities in the country. This paper provided details of a pipeline rehabilitation program conducted across 424 km of pipeline in northeastern Brazil. The pipeline crossed 32 municipal districts. Over 37 replacements and upgrades were completed as part of the rehabilitation program. Surveys were completed to verify depth of pipeline cover, as well as to examined the condition of the external pipe coating, and the operational status of the cathodic protection (CP) system. Shutdown of the pipeline was completed during a 14 hour period, and included depressurization, cutting work, welding, and repressurization. Services included pigging to evaluate pipe-wall thickness; corrosion section replacement; an investigation of class locations during the operating life of the pipeline; the replacement of some ...

2004-07-01

355

An analysis of PZR and related system design features for KNGR  

Energy Technology Data Exchange (ETDEWEB)

The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were higher and lower, respectively than those of UCN 3 and 4. Also, it ...

1995-12-01

356

Ambient air pollution and congenital heart disease: a register-based study.  

Science.gov (United States)

Maternal exposure to ambient air pollution has increasingly been linked to adverse pregnancy outcomes. The evidence linking this exposure to congenital anomalies is still limited and controversial. This case-control study investigated the association between maternal exposure to ambient particulate matter with aerodynamic diameter less than 10 ?m (PM(10)), sulfur dioxide (SO(2)), nitrogen dioxide, nitric oxide (NO), ozone (O(3)), and carbon monoxide (CO) and the occurrence of congenital heart disease in the population of Northeast England (1993-2003). Each case and control was assigned weekly average (weeks 3-8 of pregnancy) of pollutant levels measured by the closest monitor to the mother's residential postcode. Using exposure as both continuous and categorical variables, logistic regression models were constructed to quantify the adjusted odds ratios of exposure to air pollutants and the occurrence of each outcome group. We found exposure to CO and NO to be associated with ...

2011-02-17

357

Advanced PWR technology development -Development of advanced PWR system analysis technology-  

Energy Technology Data Exchange (ETDEWEB)

The primary scope of this study is to establish the analysis technology for the advanced reactor designed on the basis of the passive and inherent safety concepts. This study is extended to the application of these technology to the safety analysis of the passive reactor. The study was performed for the small and medium sized reactor and the large sized reactor by focusing on the development of the analysis technology for the passive components. Among the identified concepts the once-through steam generator, the natural circulation of the integral reactor, heat pipe for containment cooling, and hydraulic valve were selected as the high priority items to be developed and the related studies are being performed for these items. For the large sized passive reactor, the study plans to extend the applicability of the best estimate computer code RELAP5/MOD3 which is widely used for the safety analyses of the reactor system. The improvement and supplementation study of ...

1995-07-01

358

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both extensibility and flexibility. As a result, the complexity of the hardware is ...

2001-07-20

359

The new 2.2l ECOTEC aluminium engine by OPEL; Der neue 2,2l ECOTEC Aluminium Motor von OPEL  

Energy Technology Data Exchange (ETDEWEB)

The ECOTEC is a mass-efficient gasoline DOHC 4-valve per cylinder engine with balance shafts, chain driven camshafts and roller finger followers with hydraulic lash adjusters for valve actuation. It has lightweight aluminium components such as camcover, cylinder head, cylinder block, lower crankcase and structural oil pan. Other features include composite intake manifold and a coil-on-plug ignition cassette. The ECOTEC combustion system and engine architecture are optimized for low engine out and tail pipe emissions. It also includes several designed-in 'green' features for environmental benefits. The product design, development and validation process drew upon the best knowledge and practices available worldwide both inside and outside General Motor. The manufacturing systems were also designed by leveraging the best available knowledge around the world resulting in implementation of world class processes and error proofing ...

2000-07-01

360

STOMP Subsurface Transport Over Multiple Phases Version 1.0 Addendum: ECKEChem Equilibrium-Conservation-Kinetic Equation Chemistry and Reactive Transport  

Energy Technology Data Exchange (ETDEWEB)

Geologic sequestration is currently being practiced and scientifically evaluated as a critical component in a broad strategy, comprising new practices and technologies, for mitigating global climate change due to anthropogenic emissions of CO2. Demonstrating that geologic sequestration of CO2 is safe and effective, and gaining public acceptance of sequestration technologies are critically important in meeting these global climate change challenges. Monitored field-scale demonstrations of geologic sequestration of carbon dioxide will contribute greatly toward growing trust and confidence in the technology; however, pilot demonstrations ultimately will not be the norm for new geological sequestration deployments. Instead, scientists, engineers, regulators, and ultimately the public will rely on numerical simulations to predict the performance of geologic repositories for carbon dioxide sequestration. The U.S. Department of Energy (DOE), through the National Environmental Technology ...

2005-12-01

361

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace ...

2005-09-07

362

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as ...

2003-07-01

363

The US Advanced Liquid Metal Reactor and the Fast Flux Test Facility Phase IIA passive safety tests  

International Nuclear Information System (INIS)

This report discusses the safety approach of the Advanced Liquid Metal reactor program, sponsored by the US Department of Energy, which relies upon passive reactor responses to off-normal condition to limit power and temperature excursions to levels that allow safety margins. Gas expansion modules (GEM) have included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Preapplication safety evaluations by the US Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned on, resulting in positive reactivity being added to the core. Tests to examine such transients have been ...

1992-10-25

364

The U.S. Advanced Liquid Metal Reactor and the fast flux test facility phase IIA passive safety tests  

International Nuclear Information System (INIS)

The safety approach of the Advanced Liquid Metal Reactor program, sponsored by the U.S. Department of Energy, relies upon passive reactor responses to off-normal conditions to limit power and temperature excursions to levels that allow large safety margins. Gas expansion modules (GEM) have been included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Pre-application safety evaluations by the U.S. Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned on, resulting in positive reactivity being added to the core. Tests to examine such transients have been performed ...

365

SLAROM-UF: Ultra fine group cell calculation code for fast reactor  

International Nuclear Information System (INIS)

A cell calculation code SLAROM-UF was developed to improve calculation accuracy of effective cross sections for various fast reactor types. SLAROM-UF has a capability to calculate effective cross sections in ultra fine groups of about 100,000 below 50keV and in fine groups above the energy (maximum 900 groups). Resonance interaction among the fuel, the coolant, and the structure materials can be treated accurately even in a heterogeneous cell structure. Temperature can be set up freely in a cell by the ultra fine group calculation. Improvement in nuclear characteristics was observed in the analysis of JUPITER critical experiment, as 0.1% for criticality, 4% for sodium void reactivity, several % for radial reaction rate distribution, when SLAROM-UF was used instead of the typical cell calculation code. The effect of the ultra fine group calculation is remarkable in the non-leakage term of sodium void reactivity, and that of the fine group calculation is in the case ...

366

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to $1,500K per annum just ...

1997-02-01

367

Report on the achievements in research and development of a coal liquefaction technology in the Sunshine Project in fiscal 1981. Development of a solvent extraction and liquefaction plant (research and development of secondary hydrogenation); 1981 nendo sekitan ekika gijutsu no kenkyu kaihatsu, yozai chushutsu ekika plant no kaihatsu seika hokokusho. Niji suiten no kenkyu kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

Among the items of the Sunshine Project in fiscal 1981 for development of a solvent extraction and liquefaction plant, this paper describes the achievements in developing secondary hydrogenation. A small continuous hydrogenation device equipped with three reaction columns that can be filled with catalyst of 50 cc, and a dedicated testing room were designed, and orders were placed with manufacturers. The fabrication, assembly, delivery, installation, piping and wiring were all completed. The device passed a completion inspection based on the high-pressure gas safety assurance law in December 1981. After leakage due to gas and material oil was checked, a trial operation was performed, and verified of normal operation. A screening test was carried out on three kinds of commercially available and prototype catalysts before testing the SRC containing material for studying the secondary hydrogenation. The circulating solvent having a boiling point from 180 to 430 degree ...

1982-03-01

368

Remote power systems with advanced storage technologies for Alaskan villages  

Energy Technology Data Exchange (ETDEWEB)

Remote Alaskan communities pay economic and environmental penalties for electricity, because they must import diesel as their primary fuel for electric power production, paying heavy transportation costs and potentially causing environmental damage with empty drums, leakage, and spills. For these reasons, remote villages offer a viable niche market where sustainable energy systems based on renewable resources and advanced energy storage technologies can compete favorably on purely economic grounds, while providing environmental benefits. These villages can also serve as a robust proving ground for systematic analysis, study, improvement, and optimization of sustainable energy systems with advanced technologies. This paper presents an analytical optimization of a remote power system for a hypothetical Alaskan village. The analysis considers the potential of generating renewable energy (e.g., wind and solar), along with the possibility of using energy storage to take ...

1997-12-01

369

Rehabilitation and modernization of the Jansen pumped-storage power plants; Sanierung und Modernisierung der Pumpspeicher-Kraftwerke Jansen  

Energy Technology Data Exchange (ETDEWEB)

The Jansen pumped-storage plants owned by Bayernwerk Wasserkraft AG are located on the river Pfreimd in eastern Bavaria, Germany. The group comprises the three power plants at Reisach, Tanzmuehle and Trausnitz, as well as the Rabenleite upper reservoir and two weirs. After forty years of service, the power plant group has recently been rehabilitated. The rehabilitation and modernization scheme included, inter alia, replacing the surface sealing on the upstream side of the upper reservoir dam, installing a state-of-the-art leakage and stability monitoring system, and renewing the instrumentation and control equipment in the power plants and in the central control room. Finally, the paper describes the operating experience with the new I and C systems. (orig.) [German] Die Pumpspeicherkraftwerke Jansen der Bayernwerk Wasserkraft AG befinden sich an der Pfreimd in Ostbayern. Die Kraftwerksgruppe besteht aus den 3 Kraftwerken Reisach, Tanzmuehle und Trausnitz sowie aus ...

1999-11-01

370

Quantum dot micropillars  

International Nuclear Information System (INIS)

This topical review provides an overview of quantum dot micropillars and their application in cavity quantum electrodynamics (cQED) experiments. The development of quantum dot micropillars is motivated by the study of fundamental cQED effects in solid state and their exploitation in novel light sources. In general, light-matter interaction occurs when the dipole of an emitter couples to the ambient light field. The corresponding coupling strength is strongly enhanced in the framework of cQED when the emitter is located inside a low mode volume microcavity providing three-dimensional photon confinement on a length scale of the photon wavelength. In addition, coherent coupling between light and matter, which is essential for applications in quantum information processing, can be achieved when dissipative losses, predominantly due to photon leakage out of the cavity, are strongly reduced. In this paper, we will demonstrate that high-quality, low mode volume quantum ...

2010-01-27

371

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) scattered radiation dose from irradiated materials and 3) ...

1981-01-01

372

Physics and quality assurance of low dose rate brachytherapy  

International Nuclear Information System (INIS)

Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure development: forms, checklists, test ...

373

On-site radiation exposure in severe reactor accidents: Scoping study  

Energy Technology Data Exchange (ETDEWEB)

The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation doses possibly received by control room personnel for several control room air in-leakage assumptions. For occupancy during severe ...

1990-09-01

374

Monitoring leakages on oil production offloading at open seas using statistics associated with mass balance methods  

Energy Technology Data Exchange (ETDEWEB)

Pipeline leak detection technologies can be classified according to their specificity, such as their application to offshore or onshore installations or to multi-phase or single-phase flow regimes. They can also be classified according to the technology on which they are based. Available technologies can be categorized into the following 4 groups: (1) compensated mass balance, solving steady state equations which model a specific pipeline, known as real time mode (RTM), (2) the same as group 1, but solving transient equations, known as real time transient model (RTTM), (3) pressure wave behavior, and (4) statistical modeling. Hybrids schemes can also be found. Effective leak detection systems are needed to address the increasing transformation of very large crude cargo (VLCC) ships into floating production, storage and offloading (FPSO) systems. These operations make use of short and large diameters exporting lines, and often involve the use of hoses instead of flexible pipelines. ...

2004-07-01

375

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe Microanalysis), AES (Auger Electron Spectroscopy) and XPS (X-ray Photoelectron Spectroscopy). The pitting ...

1999-07-15

376

Improvement of numerical analysis method for FBR core characteristics. 2  

Energy Technology Data Exchange (ETDEWEB)

This report is composed of the following two parts and appendix. (I) Improvement of the Method for Evaluating Reactivity Based on Monte Carlo Perturbation Theory: Theoretical formulation in Monte Carlo perturbation method had been checked, and then introduced into a calculation code. There are some cases that the results of the change of eigenvalues becomes positive or negative by changing the estimator, and there is no reasonable difference in the results between the conventional method, which does not consider the change of neutron source distribution caused by a perturbation, and the new method, which consider that change. Thus it is still necessary to check the Monte Carlo perturbation code. (II) Improvement of Nodal Transport Method for 3-D Hexagonal Geometry: We can accurately evaluate hexagonal geometry FBR core by nodal transport calculation code for hexagonal-Z geometry named `NSHEX`. However it is also found that in very heterogeneous core the results is not good enough. For ...

1997-03-01

377

Guideline for Sampling and Analysis of Tar and Particles in Biomass Producer Gases. Version 3.3  

Energy Technology Data Exchange (ETDEWEB)

This Guideline provides a set of procedures for the measurement of organic contaminants and particles in producer gases from biomass gasifiers. The procedures are designed to cover different gasifier types (updraft or downdraft fixed bed or fluidised bed gasifiers), operating conditions (0 - 900C and 0.6-60 bars) and concentration ranges (1 mg/m{sub n}{sup 3} to 300 g/m{sub n}{sup 3}). The Guideline describes a modular sampling train, and a set of procedures, which include: planning and preparation of the sampling, sampling and post-sampling, analysis, calculations, error analysis and reporting. The modular sampling train consists of 4 modules. Module 1 is a preconditioning module for isokinetic sampling and gas cooling. Module 2 is a particle collection module including a heated filter. Module 3 is a tar collection module with a gas quench (optionally by circulating a liquid), impinger bottles and a backup adsorber. Module 4 is a volume-sampling module consisting of a pump, a ...

2002-07-01

378

Glue embolization of aneurysm after stenting in canine carotid arteries-technical feasibility  

International Nuclear Information System (INIS)

Coiling or infusion of embolic materials into a wide necked aneurysm can be performed with stenting. The purpose of our study is to assess the technical feasibility of aneurysm treatment with glue embolization after stenting. We used four Wallstents for surgically repairing eight canine carotid aneurysms. After confirmation of the aneurysms on the angiogram, we introduced a 6-7 F guiding catheter in order to deploy the stents. After stenting, we passed a microcatheter into the aneurysm lumen through the stent mesh. 28% glue was slowly injected until the glue cast completely filled the lumen. We evaluated the passage of a microcatheter through the stent meshwork, formation of the glue cast and the stents' ability to protection for any leakage of glue. The follow-up angiogram was obtained for two dogs, one to three times until 8 weeks, and then we sacrificed the dogs and performed pathologic examinations. Stenting was successful in all cases except one in which the ...

2004-10-01

379

Gas evolution in aluminum electrolytic capacitors  

Science.gov (United States)

Gas evolution in aluminum electrolytic capacitors constitutes one of their main drawbacks in comparison to other types of capacitors lacking a liquid electrolyte. In this respect, one of the most common causes of failure shown by liquid electrolyte capacitors is electrolyte leakage through the seal or even explosions produced by internal pressure buildup. In order to prevent these hazards, some substances, known as depolarizers, are usually added to the capacitor electrolyte with the purpose of absorbing the hydrogen evolved at the cathode (1, 2). Although the gas evolution problem in electrolytic capacitors has been known for a long time, there is a lack of literature on both direct measurements of the gas evolved and assessments of the amount of depolarizer active for the hydrogen absorption process. Aluminum electrolytic capacitors of 100..mu..F and 40V nominal voltage, miniature type (diam 8 mm, height 18.5 mm), were manufactured under standard specifications. ...

1984-03-01

380

Flow simulation of the Component Development Integration Facility magnetohydrodynamic power train system  

Energy Technology Data Exchange (ETDEWEB)

This report covers application of Argonne National Laboratory`s (ANL`s) computer codes to simulation and analysis of components of the magnetohydrodynamic (MHD) power train system at the Component Development and Integration Facility (CDIF). Major components of the system include a 50-MWt coal-fired, two-stage combustor and an MHD channel. The combustor, designed and built by TRW, includes a deswirl section between the first and the second-stage combustor and a converging nozzle following the second-stage combustor, which connects to the MHD channel. ANL used computer codes to simulate and analyze flow characteristics in various components of the MHD system. The first-stage swirl combustor was deemed a mature technology and, therefore, was not included in the computer simulation. Several versions of the ICOMFLO computer code were used for the deswirl section and second-stage combustor. The MGMHD code, upgraded with a slag current leakage submodel, was used for the ...

1997-11-01

381

Fire preventive materials for nuclear power plants  

International Nuclear Information System (INIS)

With the fire accident in Browns Ferry nuclear power plant as a turning point, the regulation against fire has been strengthened more strictly as seen in the regulatory guide of the United States Nuclear Regulatory Commission. Fire of cables is caused by either the ignition of a cable itself or spread of fire to cables. The aspect of fire is divided into the local ignition and combution and the fire extension and prepagation because of the line-shaped configuration of cables. This report describes the prevention of the spread of fire. As the materials for the prevention of fire spread, fire spread-preventing paint ''Dannekka'', sealant ''Danseal P and L'', and fire prevention tape ''FD tape'' are reported, and the testing method and the results are described in detail. ''Dannekka'' is classified into the solvent dispersion type and the water dispersion type. It may be coated with brush or by spraying. Seal material is required not only to be flame preventive but also to be leak tight. ...

382

Field test for treatment verification of an in-situ enhanced bioremediation study  

Energy Technology Data Exchange (ETDEWEB)

Due to a leakage from a 12-inch pressurized diesel steel pipe four years ago, an area of approximately 30,000 square meters was contaminated. A pilot study applying the technology of in-situ enhanced bioremediation was conducted. In the study, a field test kit and on-site monitoring equipment were applied for site characterization and treatment verification. Physically, the enhanced bioremediation study consisted of an air extraction and air supply system, and a nutrition supply network. Certain consistent sampling methodology was employed. Progress was verified by daily monitoring and monthly verification. The objective of this study was to evaluate the capabilities of indigenous microorganisms to biodegrade the petroleum hydrocarbons with provision of oxygen and nutrients. Nine extraction wells and eight air sparging wells were installed. The air sparging wells injected the air into geoformation and the extraction wells provided the underground air circulation. ...

1995-09-01

383

Feasibility of delivering grid therapy using a multileaf collimator  

International Nuclear Information System (INIS)

The feasibility of using a multileaf collimator (MLC) for grid therapy is demonstrated in this study. Grids with the projected field openings of 10 mmx10 mm and 5 mmx5 mm were created using multiple MLC-shaped fields. The deposited doses were measured with films at different depths in a solid water phantom and compared to those of Cerrobend grid collimators of similar hole sizes and hole separations. At the depth of maximum dose (d_m_a_x), the valley-to-peak dose ratios of the MLC grids were found to be about 11% and 19% for the respective 10 mmx10 mm and 5 mmx5 mm grid openings, and those of the corresponding grid blocks were about 15% and 20%. To quantify the dose contributed by transmission in the blocked areas due to the limited leaf thickness, Monte Carlo simulations (based on convolution/superposition method) were performed to calculate the doses in the solid water phantom using an ideal MLC with no leakage and perfect divergence in both the leaf end and ...

2006-01-01

384

Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C  

Energy Technology Data Exchange (ETDEWEB)

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document conditions at time of transfer of the ...

2009-11-01

385

Fabrication and dielectric property of ferroelectric PLZT films grown on metal foils.  

Energy Technology Data Exchange (ETDEWEB)

We have grown ferroelectric Pb{sub 0.92}La{sub 0.08}Zr{sub 0.52}Ti{sub 0.48}O{sub 3} (PLZT) films on platinized silicon and LaNiO{sub 3}-buffered nickel substrates by chemical solution deposition using a sol-gel process based on acetic acid chemistry. The following measurements were obtained under zero-bias field: relative permittivity of {approx}960 and dielectric loss of {approx}0.04 on the PLZT film grown on Pt/Si substrates, and relative permittivity of {approx}820 and dielectric loss of {approx}0.06 on the PLZT film grown on LNO-buffered Ni substrates. In addition, a relative permittivity of 125 and dielectric loss of 0.02 were measured at room temperature under a high bias field of 1 x 10{sup 6} V/cm on PLZT deposited on LNO-buffered nickel substrate. Furthermore, a steady-state leakage current density of {approx}8.1 x 10{sup -9} A/cm{sup 2} and mean breakdown field strength of 1.7 x 10{sup 6} V/cm were measured at room temperature. Finally, remanent ...

2011-07-01

386

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the RE containment, the travel time for the ...

2006-11-13

387

Detection of hydrocarbon microseepage in a rain forest environment (Jurua Gas field, northern Brazil) using Landsat MSS data  

Energy Technology Data Exchange (ETDEWEB)

The Jurua gas field is the first important hydrocarbon accumulation found in the jungle-covered Solimoes basin. The tectonic framework in this area is characterized by a right-lateral transpressional zone (Jurua structural trend). Hydrocarbon traps are anticlines developed along the upthrown block of a reverse fault. The prospective 2,200-m-thick Paleozoic section is unconformably covered by a 2,800-m-thick pile of Mesozoic and Cenozoic continental sediments. Anomalous concentrations of hydrocarbons (C{sub 2}-C{sub 4}) in soil samples are concordantly aligned with the trace of the reverse fault crossing the gas field, indicating that this feature acted as a conduit for hydrocarbon microseepage. Gas-producing wells are located over a tabular watershed which coincides with the northeast-southwest Jurua structural trend. An unsupervised classification of Landsat MSS data over the gas field area reveals that one spectral class of vegetation is aligned with the Jurua structural trend. Field ...

1990-05-01

388

Chemical solution deposition of ferroelectric lead lanthanum zirconate titanate films on base-metal foils.  

Energy Technology Data Exchange (ETDEWEB)

Development of electronic devices with better performance and smaller size requires the passive components to be embedded within a printed wire board (PWB). The 'film-on-foil' approach is the most viable method for embedding these components within a PWB. We have deposited high-permittivity ferroelectric lead lanthanum zirconate titanate (Pb{sub 0.92}La{sub 0.08}Zr{sub 0.52}Ti{sub 0.48}O{sub x}, PLZT 8/52/48) films on base metal foils by chemical solution deposition. These prefabricated capacitor sheets can be embedded into PWBs for power electronic applications. To eliminate the parasitic effect caused by the formation of a low-permittivity interfacial oxide, a conductive buffer layer of lanthanum nickel oxide (LNO) was applied by chemical solution deposition on nickel foil before the deposition of PLZT. With a {approx} 0.7-{micro}m-thick ferroelectric PLZT film grown on LNO-buffered nickel foil, we measured capacitance densities of 1.5 {micro}F/cm{sup 2}, breakdown ...

2009-01-01

389

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator tubes can potentially be subject to adverse environmental conditions which will cause ...

1996-06-01

390

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and energy transfer are modelled with the closure laws. The governing equations are solved with the SIMPLE type ...

2004-07-01

391

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes very long resulting ...

2005-11-23

392

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. Confusions for the inspected tubes may occur from deflection of the manipulators. To reduce the deflections ...

2010-10-01

393

5.6-nm p"+/n junction formation for sub-0.05-#mu#m PMOSFETs by using low-energy B_1_0H_1_4 ion implantation  

International Nuclear Information System (INIS)

Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, TED was suppressed in the p"+/n junction implanted at 2 keV and a dosage of 1 X 10"1"3 /cm"2, and the formation of only a 5.6-nm ultra-shallow junction was identified. ...

2004-06-01

394

166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment  

International Nuclear Information System (INIS)

Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and ...

2002-09-01

395

Heat management through intelligent components in the cooling system; Waermemanagement durch intelligente Komponenten im Kuehlkreislauf  

Energy Technology Data Exchange (ETDEWEB)

The further optimisation and improvement of the efficiency of internal combustion engines require the realisation of new technologies leading to a distinctively faster warm-up behaviour of the coolant and lubricants as well as of the engine components after a cold start. In order to achieve reduced fuel consumption and exhaust gas emissions with the help of heat management, the design criteria of innovative cooling systems need to be reflected and adapted to future requirements. The use of intelligent components within the cooling system, such as the 'Stand Alone Rotary Valve' as a thermostat's substitute or the use of coolant pumps with a rotary valve integrated into the pump's inlet chamber, offer new ways to realise in a decisively quicker and more flexible way the appropriate heating up and cooling down procedures at varying driving conditions. A description of both of the intelligent components for the ...

2001-07-01

396

Terra Nova 2006 turnaround  

Energy Technology Data Exchange (ETDEWEB)

Petro-Canada's Terra Nova offshore oil platform was designed with the expectation that its Floating, Production, Storage and Offloading (FPSO) vessel would be taken off location for maintenance and modifications work within the first 10 years of operation. Petro-Canada's 2006 extended Turnaround project was initiated to prepare for the maintenance and transport of the FPSO. The project aimed to execute an extended turnaround in approximately 90 days. The cost of the project was estimated at $190.5 million. Shutdown occurred early on May 7, 2006 due to the failure of a generator gearbox. Staff were increased from 80 to 120 to complete critical preparation work. On June 17, the FPSO was disconnected and departed for Conception Bay. A turret cover plate was installed, and the FPSO began its voyage to a Rotterdam shipyard in the Netherlands. In order to complete the journey, a comprehensive marine transit manual and emergency response plan was needed. The vessel transited ...

2006-07-01

397

Soot and NO(x) emissions and combustion characteristics of low heat rejection direct injection diesel engines. Final report, 1 September 1989-31 August 1994  

Energy Technology Data Exchange (ETDEWEB)

Performance and emissions data were gathered on a normally aspirated single cylinder DI engine with various combinations of ceramic coatings installed. Thin ceramic thermal barrier coatings were applied to the piston crown and bowl, the head and valves, and the cylinder liner. The coated piston and head were run singly and in combination with the cylinder liner to investigate the effects of these different coated surfaces on emissions and performance. Coating the piston crown alone results in generally lower cylinder pressure, lower brake specific fuel consumption and lower NO(x) emission compared to the baseline engine. Soot emission is typically increased below 2000 RPM and decreased above 2000 RPM. Coating the head alone reduces cylinder pressure, but generally increases specific fuel consumption and NO(x) and soot emission. The KIVA-II code was used to model the Hydra engine with the thermal coatings. The computer modeling has led to an understanding of the ...

1994-01-10

398

Series hybrid vehicles and optimized hydrogen engine design  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore, Sandia Livermore and Los Alamos National Laboratories have a joint project to develop an optimized hydrogen fueled engine for series hybrid automobiles. The major divisions of responsibility are: system analysis, engine design and kinetics modeling by LLNL; performance and emission testing, and friction reduction by SNL; computational fluid mechanics and combustion modeling by LANL. This project is a component of the Department of Energy, Office of Utility Technology, National Hydrogen Program. We report here on the progress on system analysis and preliminary engine testing. We have done system studies of series hybrid automobiles that approach the PNGV design goal of 34 km/liter (80 mpg), for 384 km (240 mi) and 608 km (380 mi) ranges. Our results indicate that such a vehicle appears feasible using an optimized hydrogen engine. The impact of various on-board storage options on fuel economy are evaluated. Experiments with an available engine at the Sandia Combustion ...

1995-05-10

399

Series hybrid vehicles and optimized hydrogen engine design  

Science.gov (United States)

Lawrence Livermore, Sandia Livermore and Los Alamos National Laboratories have a joint project to develop an optimized hydrogen fueled engine for series hybrid automobiles. The major divisions of responsibility are: system analysis, engine design and kinetics modeling by LLNL; performance and emission testing, and friction reduction by SNL; computational fluid mechanics and combustion modeling by LANL. This project is a component of the Department of Energy, Office of Utility Technology, National Hydrogen Program. We report here on the progress on system analysis and preliminary engine testing. We have done system studies of series hybrid automobiles that approach the PNGV design goal of 34 km/liter (80 mpg), for 384 km (240 mi) and 608 km (380 mi) ranges. Our results indicate that such a vehicle appears feasible using an optimized hydrogen engine. The impact of various on-board storage options on fuel economy are evaluated. Experiments with an available engine at the Sandia Combustion ...

1995-05-01

400

Radiation resistance of flexible graphites  

International Nuclear Information System (INIS)

Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure natural graphite were found to be radiation-resistant and suitable for use as seals and planar gaskets ...

401

PDIM - multifunction regulator; PDIM - Die integrierte Druckreduzier- und Messanlage fuer Gas  

Energy Technology Data Exchange (ETDEWEB)

The PDIM multifunction regulator offers in one single unit the basic functions filtering, slamshut safety valve, pressure reduction and a gas flow straightening vane. This concept formulated by the engineer J.-P. Cornil is a Gaz de France patent. Developed and manufactured by a French industrial company it incorporates some astute innovations in the field of fluid dynamics. Its technical caracteristics make a significant step forward in gas technology. Since the first unit was brought into service over 1000 PDIM units have been built and incorporated in gas regulating and metering stations for transport, distribution and industrial applications. The very compact nature of the PDIM enhanced by its direct bolting to a turbine or other type of gas meter leads to small size stations allowing lower cost projects and making it easier to set in populated or architecturally significant areas. (orig.) [Deutsch] Der PDIM ist eine Verschmelzung der Funktionselemente ...

1997-12-31

402

Long pulse chemical laser. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD funded theoretical study on cold cloud ...

1989-02-01

403

Hybrid vehicle system studies and optimized hydrogen engine design  

Energy Technology Data Exchange (ETDEWEB)

We have done system studies of series hydrogen hybrid automobiles that approach the PNGV design goal of 34 km/liter (80 mpg), for 384 km (240 mi) and 608 km (380 mi) ranges. Our results indicate that such a vehicle appears feasible using an optimized hydrogen engine. We have evaluated the impact of various on-board storage options on fuel economy. Experiments in an available engine at the Sandia CRF demonstrated NO{sub x} emissions of 10 to 20 ppM at an equivalence ratio of 0.4, rising to about 500 ppm at 0.5 equivalence ratio using neat hydrogen. Hybrid simulation studies indicate that exhaust NO{sub x} concentrations must be less than 180 ppM to meet the 0.2 g/mile ULEV or Federal Tier II emissions regulations. LLNL has designed and fabricated a first generation optimized hydrogen engine head for use on an existing Onan engine. This head features 15:1 compression ratio, dual ignition, water cooling, two valves and open quiescent combustion chamber to minimize ...

1995-04-26

404

Heat transfer characteristics of horizontal steam generators under natural circulation conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the heat transfer characteristics of horizontal steam generators, particularly under natural circulation (decay heat removal) conditions on the primary side. Special emphasis is on the inherent features of horizontal steam generator behaviour. A mathematical model of the horizontal steam generator primary side is developed and qualitative results are obtained analytically. A computer code, called HSG, is developed to solve the model numerically, and its predictions are compared with experimental data. The code is employed to obtain for VVER 440 steam generators quantitative results concerning the dependence of primary-to-secondary heat transfer efficiency on the primary side flow rate, temperature and secondary level. It turns out that the depletion of the secondary inventory leads to an inherent limitation of the decay energy removal in VVER steam generators. The limitation arises as a consequence of the steam generator tube bundle geometry. As an example, it is ...

1996-10-01

405

Fuel cell processor with low-temperature PEM fuel cell - testing. Final report; Naturgasreformersystem med lavtgemperatur-PEM braendselsceller - TEST. Slutrapport  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the project is to further develop a Danish natural gas reformer system including optimisation of subsystems and the overall system consisting of a natural gas reformer and fuel cell CHP generator. This will contribute to the evaluation of to what extend Denmark shall develop small reformer units for PEM fuel Cells. In the project a reformer system with a high degree of automatic control has been build that fulfils the CHP requirements to operation time, dynamics etc. This work, with a FP05 reformer unit, has given valuable results concerning the possibilities and limitations of the reformer technology for CHP usage. It is important that the reformer and fuel cell units are designed with matching yields to optimise efficiency, turn-down start-up time etc. The burner that delivers heat for the steam reaction shall be able to use natural gas as fuel. This gives the possibility of using existing burner technology. In addition this will improve the efficiency since it will ...

2006-11-03

406

Finalisation of design provision for active process water system shut down at TAPP-3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained within limits. A design provision is made at TAPP-3 and 4 to interconnect APW system of both units in such a way that one unit in addition to its own APW requirement can provide limited supply to shutdown heat ...

2006-11-13

407

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel: In natural convection dominated flow regimes  

Energy Technology Data Exchange (ETDEWEB)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated in the natural convection dominated region for a wide range of Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.02 {<=} w{sub in} {<=} 0.025 m/s) using a flow rate control valve so that Reynolds number was always about Re = 250. Experiments were conducted for modified Rayleigh numbers 3 x 10{sup 7} < Ra{sup *} < 6 x 10{sup 8} and Richardson number ...

2009-10-15

408

Experimental Investigation of Fuel-Reactivity Controlled Compression Ignition (RCCI) Combustion Mode in a Multi-Cylinder, Light-Duty Diesel Engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental study was performed to provide the combustion and emission characteristics resulting from fuel-reactivity controlled compression ignition (RCCI) combustion mode utilizing dual-fuel approach in a light-duty, multi-cylinder diesel engine. In-cylinder fuel blending using port fuel injection of gasoline before intake valve opening (IVO) and early-cycle, direct injection of diesel fuel was used as the charge preparation and fuel blending strategy. In order to achieve the desired auto-ignition quality through the stratification of the fuel-air equivalence ratio ( ), blends of commercially available gasoline and diesel fuel were used. Engine experiments were performed at an engine speed of 2300rpm and an engine load of 4.3bar brake mean effective pressure (BMEP). It was found that significant reduction in both nitrogen oxide (NOx) and particulate matter (PM) was realized successfully through the RCCI combustion mode even without applying exhaust gas ...

2011-03-01

409

Electric utility engineer`s FGD manual -- Volume 2: Major mechanical equipment; FGD proposal evaluations; Use of FGDPRISM in FGD system modification, proposal, evaluation, and design; FGD system case study. Final report  

Energy Technology Data Exchange (ETDEWEB)

Part 2 of this manual provides the electric utility engineer with detailed technical information on some of the major mechanical equipment used in the FGD system. The objectives of Part 2 are the following: to provide the electric utility engineer with information on equipment that may be unfamiliar to him, including ball mills, vacuum filters, and mist eliminators; and to identify the unique technique considerations imposed by an FGD system on more familiar electric utility equipment such as fans, gas dampers, piping, valves, and pumps. Part 3 provides an overview of the recommended procedures for evaluating proposals received from FGD system vendors. The objectives are to provide procedures for evaluating the technical aspects of proposals, and to provide procedures for determining the total costs of proposals considering both initial capital costs and annual operating and maintenance costs. The primary objective of Part 4 of this manual is to provide the utility ...

1996-03-04

410

Development of a HVDC prototype breaker. Final report  

Energy Technology Data Exchange (ETDEWEB)

The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. ...

1980-06-01

411

Corrected transposition of the great arteries  

International Nuclear Information System (INIS)

The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus and 1 case has levocardia with situs inversus. 2. Segmental sets are (S, L, L) in 15 ...

1981-12-01

412

Achievement report in fiscal 2000. Model project to reduce electric power consumption at cement burning plant; 2000 nendo seika hokoku. Semento shosei plant denryoku shohi sakugen model jigyo  

Energy Technology Data Exchange (ETDEWEB)

In order to serve for efficient energy utilization and environmental improvement in the Republic of Vietnam, a 'Model project to reduce electric power consumption at cement burning plant' has been implemented. This paper summarizes the achievements. This project is intended to add an advanced, matured and reliable electric power generation facility using cement waste heat to the existing cement plant in Vietnam to produce steam and generate power by utilizing the waste heat generated from the preheating process in the burning plant. The present project has performed the detailed designing on the piping, electric facilities and instrumentation based on the basic agreement on the project. Fabrication of the piping has been executed by the Vietnam side. Valves and electric devices were procured and transported, including those fabricated in the previous fiscal year. Technology guiding personnel were sent for unpacking inspection, installation ...

2002-03-01

413

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in establishing regulatory requirements are summarized as follows : the ...

2001-01-15

414

Sol-gel synthesis of high-quality SrRuO{sub 3} thin film electrodes suppressing the formation of detrimental RuO{sub 2} and the dielectric properties of integrated lead lanthanum zirconate titanate films.  

Science.gov (United States)

A facile solution chemistry is demonstrated to fabricate high-quality polycrystalline strontium ruthenium oxide (SrRuO{sub 3}) thin film electrodes on silicon substrates suppressing the formation of undesired ruthenium oxide (RuO{sub 2}) for the deposition of dielectric and ferroelectric materials like lead lanthanum zirconate titanate (PLZT). The robust, highly crystalline SrRuO{sub 3} film fabrication process does not favor the formation of RuO{sub 2} because of molecular level modification of the precursors possessing analogous melting points, yielding homogeneous films. This chemistry is further understood and complemented by kinetic and thermodynamic analysis of the DTA data under nonisothermal conditions, with which the activation energies to form RuO{sub 2} and SrRuO{sub 3} were calculated to be 156 {+-} 17 and 96 {+-} 10 kJ/mol, respectively. The room-temperature resistivity of the SrRuO{sub 3} film was measured to be 850 {+-} 50 {mu}{Omega} cm on silicon (100) substrates. The ...

2011-01-01

415

Operation experience with the 3 MW TRIGA Mark-II research reactor of Bangladesh  

International Nuclear Information System (INIS)

The 3 MW TRIGA Mark-II research reactor of Bangladesh Atomic Energy Commission (BAEC) has been operating since September 14, 1986. The reactor is used for radioisotope production ("1"3"1I, "9"9"mTc, "4"6Sc), various R and D activities and manpower training. The reactor has been operated successfully since it's commissioning with the exception of a few reportable incidents. Of these, the decay tank leakage incident of 1997 is considered to be the most significant one. As a result of this incident, reactor operation at full power under forced-convection mode remained suspended for about 4 years. During that time, the reactor was operated at a power level of 250 kW so as to carry out experiments that require lower neutron flux. This was made possible by establishing a temporary by pass connection across the decay tank using local technology. The other incident was the contamination of the Dry Central Thimble (DCT) that took place in March 2002 when a pyrex vial ...

2004-09-15

416

Hyperspectral and Multispectral Remote Sensing at Uranium Processing Facilities  

Energy Technology Data Exchange (ETDEWEB)

Many mines and processing facilities are in remote, difficult to access areas, or are in areas where access is limited or restricted for national reasons. In a joint project with Canada Centre for Remote Sensing, the Canadian Safeguards Support Program is investigating utility of multi- and hyperspectral remote sensing for remotely inspecting such site. With a view to eventually using the hyperspectral satellite data now coming available, airborne data over uranium and copper mine tailings and uranium processing facilities in northern Canada were acquired. The objective of this work is to demonstrate that multispectral and hyperspectral data can provide complementary and supplementary information to high-resolution panchromatic imagery for the following safeguards applications: Inspection aids (up-to-date maps of remote locations), change detection, evaluation of member state declarations, monitoring of reactor, mining and processing facility operations, and detection of undeclared ...

2003-05-01

417

Development of Guide System for a Reactor Head Maintenance Robot  

Energy Technology Data Exchange (ETDEWEB)

The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address CRD nozzle inspection ...

2005-07-01

418

Calibration and analysis of soil carbon efflux estimates with closed chambers at Forsmark and Laxemar  

International Nuclear Information System (INIS)

The Forsmark and the Laxemar investigation areas are examined by the Swedish Nuclear Fuel and Waste Management Co. for a possible construction of a deep repository for nuclear waste. In the case of a future leakage of waste, the radioactive isotopes could end up in the ecosystems above the repository. The fate of the radionuclides and their possible radiological impacts are then highly determined by ecosystem carbon cycling. An important part of the carbon cycling is the soil carbon effluxes, and in the investigation areas soil carbon effluxes have been examined with the closed chamber technique. This paper is divided into two parts. Firstly, there were problems with the equipment measuring the soil carbon dioxide efflux, and the first part is a description of the problem, how it was corrected and its possible causes. The second part is a manual in how to analyse data and calculate annual estimates of soil carbon efflux. The field measurement by the EGM-4 is just ...

2007-01-01

419

Transpositions and malpositions of the great arteries  

International Nuclear Information System (INIS)

The transposition of the great arteries afters to an abnormal connection and relation of the great arteries in which the aorta arises from the morphologic right ventricle and the pulmonary artery from the morphologic left ventricle, while the malposition of the great arteries indicates an abnormal relationship between the great arteries in which the great arteries are not transposed across the ventricular septum but they are malposed, as is seen in double outlet right ventricle, double outlet left ventricle and single ventricles. Transpositions and malpositions of the great arteries are understood as a spectrum of malformation caused by abnormal conal development and can be included in the common category of 'conotruncal malpositions'. Authors analized 32 cases of transpositions and malpositions of the great arteries in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 17 months, with specific references to the ...

1980-12-01

420

Supervision of construction, quality assurance, operating experience in the new heating power station II; Bauueberwachung, Qualitaetssicherung, Betriebserfahrungen mit dem neuen Heizkraftwerk II  

Energy Technology Data Exchange (ETDEWEB)

After 3 years of construction the trial run of the heating power station HKW 2 ended in November 1997 on time. No extraordinary damage occured during construction, assembly or commissioning. The plant has been operating according to schedule since November 1997. A brief inspection carried out in the summer of 1998 in order to assess warranty claims showed no damage to any part except one valve. Experience shows that all aforementioned activities were necessary. The paper reports about success and negative experience. Certification according to DIN EN ISO 9000ff., however, affords to guarantee of high-quality construction. Builders of such plants therefore need to set up their own quality assurance centre and ensure its technical competence. If necessary,additional experts should be called in.Quality assurance costs for HKW 2 came to about 0.5-0.6 percent of total costs. In view of the success and long life of this investment these expenses are more than justified. ...

1998-07-01

421

LOBI/B-R1M, Loop for Blowdown Investigation, PWR Single-Ended Cold-Leg Break Experiment B EXP.B  

International Nuclear Information System (INIS)

1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be simulated. The LOBI test facility is the only high pressure integral test facility within the European Communities (1982), built and operated in the Joint Research ...

422

Characterization of Single-Cylinder Small-Bore 4-Stroke CIDI Engine Combustion  

Energy Technology Data Exchange (ETDEWEB)

Direct injection diesel engines power most of the heavy-duty vehicles. Due to their superior fuel economy, high power density and low carbon dioxide emissions, turbocharged, small bore, high speed, direct injection diesel engines are being considered to power light duty vehicles. Such vehicles have to meet stringent emission standards. However, it is difficult to meet these standards by modifying the in-cylinder thermodynamic and combustion processes to reduce engine-out emissions. After-treatment devices will be needed to achieve even lower emission targets required in the production engines to account for the anticipated deterioration after long periods of operation in the field. To reduce the size, mass and cost of the after-treatment devices, there is a need to reduce engine-out emissions and optimize both the engine and the aftertreatment devices as one integrated system. For example, the trade-off between engine-out NOx and PM, suggests that one of these species can be minimized ...

2005-11-30

423

Criticality experiments: analysis, evaluation, and programs. 6. CORAL-I Reactor: Evaluation of Critical Experiments and Mass Reactivity Coefficient Measurement  

International Nuclear Information System (INIS)

CORAL-I was an experimental, zero-power, fast-spectrum, high-enriched metal uranium reactor that operated from 1968 until 1988 at the former Junta de Energia Nuclear (JEN), CIEMAT at present. The critical measurements performed at the startup of the reactor are being evaluated as part of the International Critical Safety Benchmark Evaluation Program (ICSBEP) and proposed to be included in its 2001 edition. Additionally, the measurement of the mass reactivity coefficient is compared with MCNP4B calculations. This measurement allows one to perform the approach to critical without the need of a previous control rod calibration, thus enhancing the safety of such an approach. This technique can also be applied to other reactor types. CORAL-I (Ref. 1) is a 90% enriched metal uranium reactor domestically designed and manufactured in the experimental facilities of JEN, now CIEMAT, in Madrid, Spain. The enriched uranium was supplied by the International Atomic Energy Agency as metal ingots and ...

2001-06-17

424

TRITEX. A ferritic steel loop with Pb-15.8Li. Facility and operation  

Energy Technology Data Exchange (ETDEWEB)

TRITEX was a pumped loop with Pb-15.8Li, fabricated from steel 1.4922. In contact with the molten eutectic were also molybdenum, vanadium and armco-iron. The loop was originally designed to investigate tritium extraction using solid getter metals. Over the years the goal changed to the study of metals, corrosion products and purification of the eutectic mixture. Therefore many modifications were done. The first part of this report describes TRITEX. All parts were enclosed in thermoboxes for a homogeneous temperature. One test section was in an argon glove box and could be opened during operation. Other special equipment`s were: permeation membranes and liquid-metal-covergas-interfaces to study the transport of H{sub 2}, D{sub 2} and {sup 3}H, different purification devices, a quartz observation window to see the liquid metal surface, 4 different kinds of flow measurements, level indicators, freeze valves. The second part describes loop operation. Between 1989 and ...

1999-05-01

425

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance of nucleate boiling ...

2002-07-01

426

A micromachined high pressure stable mass flow sensor for common-rail injection systems; Ein mikromechanisch gefertigter hochdruckstabiler Massenflusssensor fuer Common-Rail(CR)-Einspritzsysteme  

Energy Technology Data Exchange (ETDEWEB)

We report for the first time about a micromachined mass flow sensor directly integrated between the double guidance and the needle seat into the body of a Common Rail (CR) injection nozzle. The thermal measurement principle was chosen because gaseous as well as liquid mass flows can be determined fast and precisely. Additionally, with glass-ceramic materials fabricated in a low cost batch process, a high temperature and especially pressure stable substrate can be used. The flow sensitive thin film is realized by an e-beam evaporated 110 nm thick molybdenum (Mo) layer. The latter is electrically characterized by the resistivity of {rho} = 8.2 x 10{sup -7} {omega} m ({+-}2%) at room temperature as well as by the first {alpha}=4.5 x 10{sup -4} K{sup -1} ({+-}5%) and second {beta}=3.0 x 10{sup -6} K{sup -2} ({+-}12%) temperature coefficients of resistance up to 300 C. The static temperature field at and around the thin film sensor on the glass-ceramic substrate is investigated with an IR ...

2001-05-01

427

Funding programme ``30 low energy buildings in Hesse`` - experience and conclusion; Foerderprogramm `30 Niedrigenergiehaeuser in Hessen` - Erfahrungen und Schlussfolgerungen  

Energy Technology Data Exchange (ETDEWEB)

Low energy buildings promise significant energy savings and help climate preservation by cutting down on annual heating requirements to values below 70 kWh per m{sup 2} dwelling space. It is expected that low energy constructions will become the common standard by the year 2000 as a result of the forthcoming energy saving ordinance. For making the introduction and implementation of this standard successful, practical experience will be essential. For this reason, the state government of Hesse has supported respective pilot projects 1987. In 1989 the funding programme `30 low energy buildings in Hesse` has been established. Consecutively - between 1989 and 1993 - 29 buildings were erected. At first, the thermal quality of the crafted building construction including the ventilation systems was checked. Consecutively, energy consumption, indoor and outdoor temperatures were measured over a time span of several years. The experience of the inhabitants was surveyed. The `Institut Wohnen und ...

1998-10-01