International Nuclear Information System (INIS)
Platelet deposition on bovine pericardial-tissue mitral-valve prostheses in 11 dogs was observed noninvasively by use of "1"1"1In-labeled platelets and quantified after sacrifice at one (n . 3), 14 (n . 3), and 30 (n . 5) days postimplantation (300-400 microCi of labeled platelets having been injected 24 hours previously). Thrombosis on the sewing ring and pericardial leaflets at one and 14 days and on the leaflets at 30 days was delineated in scintiphotos. In vitro quantification (% injected dose) indicated that the leaflets, sewing ring, and perivalvular tissue retained 0.904% of labeled platelets at one day postimplantation, 0.198% at 14 days, and 0.040% at 30 days. Platelet half-life was reduced to 38 hours at 21 days postimplantation but returned toward the normal (50 hours) with fibrous ingrowth in the sewing ring. Microembolism in lung and kidney, as measured by tissue/blood radioactivity ratio, ...
Platelet thrombosis in cardiac-valve prostheses
International Nuclear Information System (INIS)
The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue ...
1989-06-08
Accelerated interleaflet transport of phosphatidylcholine molecules in membranes under deformation.
UK PubMed Central (United Kingdom)
Biological membranes are lamellar structures composed of two leaflets capable of supporting different mechanical stresses. Stress differences between leaflets were generated during micromechanical experiments...Full Text Available
1996-09-01
Repair of a Complex Congenital Cardiac Defect
... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...
UK PubMed Central (United Kingdom)
Previous studies reveal that dark-induced closure of Samanea leaflets is accompanied by H+ secretion from flexor motor cells. We now report that flexor tissue excised in...Full Text Available
1987-11-01
TECHNICAL REPORT - NASA Technical Reports Server
VORTEX VALVE FLOW CHARACTERISTICS. 49. VENTED VORTEX VALVE. 50. VORTEX DIVERTER VALVE- ... 46 AND VORTEX MIXING VALVE FLOW CHARACTERISTICS ...
X-Plain Heart Valve Replacement Reference Summary Introduction Sometimes people have serious problems with their heart valves. A heart valve repair or ...
UK PubMed Central (United Kingdom)
The Dot/Icm type IV translocated Ankyrin B (AnkB) effector of Legionella pneumophila is modified by the host prenylation machinery that anchors it into the outer leaflet of the Legionella-containing...Full Text Available
Freeze protection valve for solar heaters
Energy Technology Data Exchange (ETDEWEB)
This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway ...
1987-07-21
RESEARCH STUDY OF THE VORTEX VALVE FOR - NASA Technical Reports Server
Vortex Valve Flow Characteristics. Basic Circuit Schematic. System Test Installation. Flight-Weight Design of SITVC System. Staged Vortex Valve SITVC ...
Valve Flow Characteristics. 3-68. 3-40. Valve Operating Current Vs. Temperature ...... VALVE FLOW CHARACTERISTICS. Acceptance Test 4/29/74. SINs 002 & 004 ...
W-12 valve pit decontamination demonstration
Energy Technology Data Exchange (ETDEWEB)
Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste connection. Remote ...
1995-12-01
A study on modelling of a butterfly-type control valve by a pneumatic actuator
Energy Technology Data Exchange (ETDEWEB)
This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.
2009-07-01
Stable iodine prophylaxis. Recommendations of the 2nd UK Working Group on Stable Iodine Prophylaxis
International Nuclear Information System (INIS)
The Working Group reviewed the revised Who guidance and the information published since 1991 on the risks of thyroid cancer in children from radioiodine and the risks of side effects from stable iodine. In particular, it reviewed data compiled on the incidence of thyroid cancers in children following the accident at the Chernobyl nuclear power plant in 1986. It considered whether the NRPB Earls were still appropriate, in the light of the new data. It also reviewed a range of other recommendations given by the 1st Working Group, concerning the chemical form of stable iodine tablets and practical issues concerning implementation of stable iodine prophylaxis. Finally, it reviewed the Patient Information Leaflet that is required, by law, to be included in each box of tablets and provided suggestions for information to be included in a separate information leaflet to be handed out to the public when stable iodine tablets are distributed
DEFF Research Database (Denmark)
BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native ...
2010-01-01
The Swedish Ceramic Institute is an industrial research institute working with product-oriented research and development of ceramics and closely related materials. The institute works with the processing and fabrication of ceramic materials as well as with materials properties and design questions. Its website provides details of research projects (engineering ceramics, electroceramics, traditional ceramics). Publications are listed, with some downloadable files (annual reports, research reports, information leaflets). Sample materials data (mechanical properties, thermal properties) is given for oxides and non-oxide ceramics.
2007-02-01
UK PubMed Central (United Kingdom)
Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available
2010-06-28
Optimization of Valve Disc Using Orthogonal Array and Kriging Model
A butterfly valve is a type of flow control device, typically used to regulate a fluid flowing. Currently, FEA is often used to predict the safety in the design of valve disc. Also, the study about the affection of butterfly valve's disc to the valve flow characteristics by using CFD has been done by many researchers. Along with the development of computer technique, design and analysis of computer experiments has becoming more and more important in engineering design and optimization. Hereinto Kriging model is one popular analysis approach for the purpose of creating a cheap ``meta-model'' as a surrogate to a computationally expensive simulation model. In this paper, the numerical analysis considered the strength, pressure loss coefficient and weight of valve disc simultaneously is investigated to improve the shape of a traditional butterfly valve disc. ...
2008-10-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned ...
1995-05-01
Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants
International Nuclear Information System (INIS)
This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV ...
1992-07-01
Technical Lio - NASA Technical Reports Server
Mod IE did not affect the valve flow characteristics. C. BIPROPELLANT -VALVE EVALUATION. 1. Ball and Shaft Seal Evaluation ...
Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability
1989-01-01
Development of linear flow rate control system for eccentric butter-fly valve
Energy Technology Data Exchange (ETDEWEB)
Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)
1999-12-01
Assessment of the radiological impact of the 50 GeV BPS on its environment In Chinese
Assessment of the radiological impact of the 50 GeV BPS on its environment
1980-01-01
Newly developed control and stop valves
International Nuclear Information System (INIS)
... bwr type reactors closures fluidic control devices operation performance pwr
International Nuclear Information System (INIS)
... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic
Thermal-hydraulic analysis following a safety flapper valve's fault for a pool-type research reactor
International Nuclear Information System (INIS)
One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)
Recycling flow control device for a nuclear reactor
International Nuclear Information System (INIS)
Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and ...
An experimental study on stable flow control for multi-stage expansion device
Energy Technology Data Exchange (ETDEWEB)
An Experimental study was performed to investigate flow characteristic of multi-stage expansion valve applied with inverter heat pump. Multi-stage expansion consists of parallel valve which is controlled on/off type of solenoid valve. Expansion valve open one solenoid the other closed in low frequency region and open two solenoid valve in high frequency region. In rated frequency region always open one solenoid valve and control period and on-off time ratio for the other solenoid valve. Flow characteristics of a orifice expansion was measured as a function of orifice diameter and operating conditions. As a results multi-stage expansion device can control a stable flow with period and on-off time ratio. (author). 4 refs., 7 figs., 1 tab.
1998-04-01
...CanCom Dermatology Image Bank Dermatology Online Atlas Introduction to Skin Cancer Malignant Melanoma Skin Cancer (Not Melanoma) Comments: bubl@bubl.ac.... Covers anatomy, melanoma, infections, and dermatological disorders in AIDS. Author: University of Utah ...994 Resource type: document Malignant Melanoma This leaflet on malignant melanoma covers early detection, causes, clinical signs and symptoms, and provides ...9 Resource type: document Skin Cancer (Not Melanoma) Information on basal cell and squamous cell skin cancers. Author: ...
Prognostic implications of pulmonary hypertension in patients with severe aortic stenosis
British Library Electronic Table of Contents (United Kingdom)
ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...
2011-01-01
Linearization of Valve Flow Characteristics for Steam Turbine Control
Energy Technology Data Exchange (ETDEWEB)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)
2009-10-15
Linearization of Valve Flow Characteristics for Steam Turbine Control
International Nuclear Information System (INIS)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)
2009-10-01
Oil pipeline valve automation for spill reduction
Energy Technology Data Exchange (ETDEWEB)
Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic ...
2009-04-15
Corrected transposition of the great arteries
International Nuclear Information System (INIS)
The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus and 1 case has levocardia with situs inversus. 2. Segmental sets ...
1981-12-01
A study on the regulatory approach of KNGR multiple failure events
Energy Technology Data Exchange (ETDEWEB)
This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in establishing regulatory requirements are summarized as follows : the ...
2001-01-15
Total prosthetic replacement of atrioventricular valves in the dog
UK PubMed Central (United Kingdom)
The metal parts of cardiac valve prostheses cause reactions in the surrounding tissues of the heart. In some dogs rather abnormal reactions were found, and were attributed to corrosion of the stainless...Full Text Available
1972-01-01
Selecting the right pumps and valves for flue gas desulfurization
Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.
2006-07-15
Percutaneous mitral valve repair: the beginning of the end or the end of the beginning?
UK PubMed Central (United Kingdom)
The new percutaneous mitral valve repair techniques are at an early stage. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary...Full Text Available
UK PubMed Central (United Kingdom)
Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
AimsTranscatheter treatment of heart valve disease is well established today. However, for the treatment of tricuspid regurgitation (TR), no effective catheter-based approach is...Full Text Available
2011-05-01
Cavitation guide for control valves
Energy Technology Data Exchange (ETDEWEB)
This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of ...
1993-04-01
UK PubMed Central (United Kingdom)
Study DesignThis is a retrospective study that was done according to clinical and radiological evaluation.PurposeWe analyzed the clinical and radiological...Full Text Available
2011-06-01
Diagnostic radiology: An Anglo-American textbook of imaging
Energy Technology Data Exchange (ETDEWEB)
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
1986-01-01
end of the barrel. The petal valve and ring seal are inserted behind it, and the gun barrel assembly and HP section are clamped together with hydraulic collars. ...
Evaluation of the fluid force in main feed water control valve for APWRs
International Nuclear Information System (INIS)
... 2432 v. 43(1) SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
2006-01-01
... Both effects are undoubtedly caused by the ahaping of the spool valve flow characteristics The linear region of response corresponds to ...
1975-12-01
International Nuclear Information System (INIS)
Comparison of plasma density increase was carried out in outer and inner channels of the interferometer in T-11M tokamak. There were two cases of gas puffing: by outer valve or upper one. Amplitude of difference of the plasma density increase consisted of 9% near the outer valve. Perturbation of the electric potential e?1/Te can have similar value. This perturbation can lead to appearance of the additional losses.
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond the scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and ...
1995-12-01
Dynamic performance testing of control valves
International Nuclear Information System (INIS)
Response of control valves plays an important role in the dynamics of the flow system as a whole. Knowledge of its transfer function would facilitate analysis of the behaviour of the system. This paper presents the application of Levy's complex curve fitting method for determination of the transfer function of control valves used in Liquid Zone Control System of 540 MWe PHWR. (author)
2005-02-01
A thermal valve heat flux control device
International Nuclear Information System (INIS)
In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.
1994-10-05
The importance of radiation quality for optimisation in radiology
UK PubMed Central (United Kingdom)
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Site of lupanine and sparteine biosynthesis in intact plants and in vitro organ cultures
International Nuclear Information System (INIS)
["1"4C]Cadaverine was applied to leaves of Lupinus polyphyllus, L. albus, L. angustifolius, L. perennis, L. mutabilis, L. pubescens, and L. hartwegii and it was preferentially incorporated into lupanine. In Lupinus arboreus sparteine was the main labelled alkaloid, in L. hispanicus it was lupanine. A pulse chase experiment with L. angustifolius and L. arboreus showed that the incorporation of cadaverine into lupanine and sparteine was transient with a maximum between 8 and 20 h. Only leaflets and chlorophyllous petioles showed active alkaloid biosynthesis, whereas no incorporation of cadaverine into lupanine was observed in roots. Using in vitro organ cultures of Lupinus polyphyllus, L. succulentus, L. subcarnosus, Cytisus scoparius and Laburnum anagyroides the inactivity of roots was confirmed. Therefore, the green aerial parts are the major site of alkaloid biosynthesis in lupins and in other legumes. (orig.).
1987-01-01
Linearization of Valve Flow Characteristics for Steam Turbine Control
Energy Technology Data Exchange (ETDEWEB)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.
2009-05-15
Linearization of Valve Flow Characteristics for Steam Turbine Control
International Nuclear Information System (INIS)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.
2009-05-01
Energy Technology Data Exchange (ETDEWEB)
As usual a shipping terminal contains a header and its diameter is smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves without dynamic modeling may introduce some error in the maximum pressure results without a dynamic model approach. The current paper uses commercial pipeline simulation software to model the dynamic behavior of the check valves. It was studied the header diameter influence and how the check valve model type may change the maximum pressure in the pipeline. It was proved that even a pipeline that works with low pressure and small elevation drop needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)
2005-07-01
Experimental parametric equation for the prediction of valve coefficient (C_v) for choke valve trims
International Nuclear Information System (INIS)
The calculation of nominal choke valve size determines the effective capacity for an oil and gas production system. The degree of restriction for the controlling area in the valve is a function of the surrounding geometry. In an orifice plate this is known as the 'velocity of approach' and can be used to determine the meter coefficient (C_m). This paper presents a technique for choke valves, based on the meter velocity of approach parameter, which can be used to predict the Valve Coefficient (C_v) for new trim designs. The prediction method uses a data trend based on a number of flow tests conducted on various trim characteristics. The resultant parametric equation is used to predict the C_v of a new trim geometry. The method relies on experimental data determined per IEC 60534-2-3, with calculations per IEC 60534-2-1. This paper further investigates the effect of varying upstream geometry on C_v for a ...
Radiological equipment for emergencies
Energy Technology Data Exchange (ETDEWEB)
A brief guide to training and equipment needed to effectively manage victims of radiation accidents. (DT)
1985-01-01
Transpositions and malpositions of the great arteries
International Nuclear Information System (INIS)
The transposition of the great arteries afters to an abnormal connection and relation of the great arteries in which the aorta arises from the morphologic right ventricle and the pulmonary artery from the morphologic left ventricle, while the malposition of the great arteries indicates an abnormal relationship between the great arteries in which the great arteries are not transposed across the ventricular septum but they are malposed, as is seen in double outlet right ventricle, double outlet left ventricle and single ventricles. Transpositions and malpositions of the great arteries are understood as a spectrum of malformation caused by abnormal conal development and can be included in the common category of 'conotruncal malpositions'. Authors analized 32 cases of transpositions and malpositions of the great arteries in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 17 months, with specific ...
1980-12-01
Magnetic resonance imaging in patients with heart valve prostheses
International Nuclear Information System (INIS)
Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular ...
Development of new three way valve using vacuum for liquid transfer
International Nuclear Information System (INIS)
The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)
2008-07-01
Training aids: the motor operator valve trainer
International Nuclear Information System (INIS)
The spectrum of training aids used in the nuclear industry runs the gamut from the very basic (i.e., valve training aids - gate, globe, check) to the highly complex (i.e., nuclear full scope simulator). Designing and purchasing the best training aids take much time, detailed investigation, and good understanding of plant operations. The training aid that has given the New York Power Authority the best results has been the motor operator valve (MOV) trainer. Some of the items that make the MOV trainer a good choice are: (1) large number of MOVs in the plant, (2) importance of MOVs to safe plant operation, (3) detailed MOV procedures used by the plant, (4) history of MOV problems, and (5) ability to demonstrate important concepts and operation - hammer blow effect, torque and limit switch adjustment and functions, and actual sequence of operation of the limitorque valve operator.
1987-06-07
The National Shipbuilding Research Program Task S-20: A ...
... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...
1979-05-01
Flow mapping for assessment of native and repaired valves
International Nuclear Information System (INIS)
Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.
Flow characteristics and dynamics of swing check valves in compressible flow applications (Part-1)
Energy Technology Data Exchange (ETDEWEB)
In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle vs. mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements in compressible flows. This paper presents results of steady compressible flow testing of an NPS 4 swing type check valve in air. Mean flow velocities vs. ...
1996-12-01
Effects of compressibility on flow characteristics and dynamics of swing check valves. Part 1
Energy Technology Data Exchange (ETDEWEB)
In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle versus mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements involving fluids of relatively higher compressibility. This paper presents results of steady flow testing of an NPS 4 swing-type check valve in air. Mean ...
1997-05-01
International Nuclear Information System (INIS)
Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the ...
Energy Technology Data Exchange (ETDEWEB)
As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.
1999-11-01
International Nuclear Information System (INIS)
... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,
2006-09-11
3 - NASA Technical Reports Server
Mar 1, 2011... properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. ...
OPERATION CASTLE. Radiological Safety. Volume 2.
This report is designed to cover the overall Operation Castle radiological safety matters from the viewpoint of those issues of direct concern to Headquarters, Joint Task Force Seven. It was written for the express purpose of assisting in the development ...
1985-01-01
OPERATION CASTLE. Radiological Safety. Volume 1.
This report is designed to cover the overall Operation Castle radiological safety matters from the viewpoint of those issues of direct concern to Headquarters, Joint Task Force Seven. It was written for the express purpose of assisting in the development ...
1985-01-01
Evaluation of a filmless radiology pilot--a preliminary report.
UK PubMed Central (United Kingdom)
The development of the Multimedia Electronic Medical Record System (MEMRS) promises new opportunities to significantly reduce the routine use of film as the medium for viewing radiological medical images....Full Text Available
2001-01-01
UK PubMed Central (United Kingdom)
This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available
2007-11-01
A Picture Archiving and Communication System Module for Radiology
UK PubMed Central (United Kingdom)
This paper presents the design and implementation of a clinical picture archiving and communication system (PACS) module within the radiology department of a 700-bed teaching hospital. The system is...Full Text Available
1988-11-09
International Nuclear Information System (INIS)
The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).
The Manning Requirements for the Navy's Forward ...
... Task Force Commander's Handbook for Domestic ... and Radiological (CBR) Defense Requirements Supporting ... DC: Department of Navy, May 1996 ...
2011-05-13
International Nuclear Information System (INIS)
The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).
Radiological hazards in uranium mines and a yellow-cake plant in Turkey
Energy Technology Data Exchange (ETDEWEB)
Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.
1984-06-01
UK PubMed Central (United Kingdom)
Spontaneous pneumothoraces are believed to arise when air from the supplying airway exit via a ruptured visceral pleural bleb into the pleural cavity. Endobronchial one-way valves (EBVs) allow air exit...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)
1997-12-31
Multilayer structures with giant magnetoresistance
International Nuclear Information System (INIS)
The phenomenological description of the giant magnetoresistance effect as well as discussion of the requirements which must be fulfilled in giant magnetoresistance thin film structures are given in the first part of our review. In the second part the magnetization reversal and giant magnetoresistance effect of antiferromagnetically coupled multilayers, spin Valve and pseudo-spin valve thin film structures are explained. For these structures we also discuss the influence of the structure defects such as surface roughness and pinholes on the giant magnetoresistance effect. (author)
2001-09-23
Hydraulic device for control rod drive mechanisms
International Nuclear Information System (INIS)
Purpose: To improve the reliability of control rod drive mechanisms for use in BWR type reactors by preventing erroneous insertion of control rods caused by the increase in the coolant pressure. Constitution: A pressure-releaf valve mechanism is provided which opens its valve when a detected difference between the pressure of the coolants flowing through coolant pipeways and the reactor pressure exceeds a predetermined pressure difference. If the coolant pressure increases abnormally, coolants in the coolant pipeway are released to lower the pressure. (Aizawa, K.).
1981-07-31
International Nuclear Information System (INIS)
Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, ...
UK PubMed Central (United Kingdom)
AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available
2008-10-01
Operation Castle. Radiological Safety. Volume 2. Final report
This report is designed to cover the overall Operation Castle radiological safety matters from the viewpoint of those issues of direct concern to Headquarters, Joint Task Force Seven. It was written for the express purpose of assisting in the development of future radiological safety plans by presenting detailed discussion of the problems and solutions arising during Operation Castle.
1985-09-01
Operation Castle. Radiological Safety. Volume 1. Final report
This report is designed to cover the overall Operation Castle radiological safety matters from the viewpoint of those issues of direct concern to Headquarters, Joint Task Force Seven. It was written for the express purpose of assisting in the development of future radiological safety plans by presenting detailed discussion of the problems and solutions arising during Operation Castle. Included is a discussion of fallout forecasting techniques.
1985-09-01
GS1 - radiological protection objectives for the disposal of solid radioactive wastes
Energy Technology Data Exchange (ETDEWEB)
A summary is given of the 1983 NRPB-GS1 Report on the 'Radiological protection objectives for the disposal of solid radioactive wastes'. The two principal difficulties in applying the ICRP system of dose limitation to some solid waste disposal methods are outlined. Despite these difficulties three radiological protection objectives for waste disposal were recommended based on the same fundamental principle as ICRP recommendations.
1984-01-01
FDH radiological design review guidelines
Energy Technology Data Exchange (ETDEWEB)
These guidelines discuss in more detail the radiological design review process used by the Project Hanford Management Contractors as described in HNF-PRO-1622, Radiological Design Review Process. They are intended to supplement the procedure by providing background information on the design review process and providing a ready source of information to design reviewers. The guidelines are not intended to contain all the information in the procedure, but at points, in order to maintain continuity, they contain some of the same information.
1998-09-29
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
International Nuclear Information System (INIS)
In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...
Development of magnetic drive packless valves for commercial purpose
Energy Technology Data Exchange (ETDEWEB)
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve ...
1995-09-01
International Nuclear Information System (INIS)
Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
In coke-oven operations flue-gas valves are used to switch the regenerator function from rich gas firing to lean gas firing. Compared with the simple geometry of the other parts of the flow path, which comprise flues and regenerators, the narrow and winding passages of the flue-gas valves give rise to relatively high losses in pressure. Without the construction of high (and therefore expensive) chimneys, this means that operating problems may well arise due the inadequate suction capacity. The project focused on the theoretical and experimental analysis of a coke-oven flue-gas valve. The primary aim was to reduce the pressure drop through the valve without modifying its external geomerty. The internal flow characteristics created by different valve geometries under a variety of operating conditions were simulated using the commercial CFD code Fluent/UNS, which provided velocity and ...
1999-06-01
International Nuclear Information System (INIS)
The aim of this paper is to investigate the fluid dynamic behaviour of a commercial hydraulic proportional valve in order to evaluate and justify its global performances and, in particular, to analyze the effects of some additional design features on the reduction of the force required to maintain the valve open. The proposed analysis has been performed by applying the commercial computational fluid dynamics (CFD) code, Fluent, to the solution of the three dimensional turbulent flow field through a circumferential sector of the entire valve for different spool strokes. The reliability of the employed modelization is demonstrated by the comparison between the computed flow rate curve and the corresponding experimental data provided by the manufacturer. With regard to the metering edge design, it is shown that the cylindrical hole provided on the top of the hemi-spherical notch to improve metering at small ...
2007-03-01
Energy Technology Data Exchange (ETDEWEB)
In a shipping terminal, the pipeline in the pier usually has a diameter smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves placed in the pier may introduce some error in the maximum pressure when it was modeled in a conventional fashion. The dynamic check valve model had been added to a commercial pipeline simulation software and the results was compared with a similar model using the method of characteristics. Considering a real state shipping terminal case, it was proved even a pipeline that works with low pressure and smooth elevation profile needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)
2004-07-01
Modeling of a self-excited pulse combustor and stability analysis
British Library Electronic Table of Contents (United Kingdom)
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
2011-01-01
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to the reference level and the possibility ...
1981-11-18
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).
1981-11-12
Energy Technology Data Exchange (ETDEWEB)
Twenty-four male weanling rats were fed either copper-adequate or -deficient diets until 9 or 11 weeks of age. Deficient rat hearts had increased mitochondria: myofibril compared to adequate rats. Eleven week old deficient rat hearts had decreased mitochondria: myofibril as the hearts increased in weight, but the larger hearts had greater myofibril volume densities. Cardiac mitochondria of deficient rats appeared vacuolated with fragmented cristae and translucent matrix. Valves from copper deficient rats appeared to have less connective tissue and were fragmented in areas. For deficient rats, heart:body weights of 9 wk old rats were negatively correlated with bicuspid valve pathology scores, whereas tricuspid valve scores from 11 wk old rats were negatively correlated with myofibril volume densities. These data suggest that the enlargement of the copper-deficient rat heart is due to: larger (1) mitochondria and (2) ...
1991-03-15
Primary coolant depressurization facility
Energy Technology Data Exchange (ETDEWEB)
In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible ...
1992-10-14
UK PubMed Central (United Kingdom)
BackgroundThoracic injuries play an important role in major trauma patients due to their high incidence and critical relevance. A serious consequence of thoracic trauma is pneumothorax,...Full Text Available
Lower Urinary Obstruction in Infancy
UK PubMed Central (United Kingdom)
This paper reviews 165 cases of lower urinary obstruction in infancy. The commonest lesions were posterior urethral valves (91) and ectopic ureterocele (34), stenosis or atresia of the urethra (8),...Full Text Available
1972-04-01
Hydraulic system for driving control rods
International Nuclear Information System (INIS)
Purpose: To enable safety reactor shut down upon occurrence of an abnormal excess pressure in a hydraulic control unit. Constitution: The actuation pressure for a pressure switch that generates a scram signal is set lower than the release pressure set to a pressure release valve. Thus, if the pressure of nitrogen gas in a nitrogen container increases such as upon exposure of the hydraulic control unit to a high temperature, the pressure switch is actuated at first to generate the scram signal and a scram valve is opened to supply water at high pressure to control rod drives under the driving force of the nitrogen gas at high pressure to rapidly insert the control element into the reactor and shut down it. If the pressure of the nitrogen gas still increases after the scram, the pressure release valve is opened to release the nitrogen gas at high temperature to the atmosphere. Since the scram is attained before the actuation ...
1980-11-07
EDF's experience in the operation of pump-storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.
1992-01-01
Double-Valve Libman-Sacks Endocarditis Causing Ventricular Fibrillation Cardiac Arrest
UK PubMed Central (United Kingdom)
Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This report deals with the establishment of durability and reliability for the new type decompression brake system for large diesel engines. By testing engines on the bench, it has been found that the cylinder pressure, with the cylinder at the compression stroke upper dead center, imposed on the exhaust valve bevel section during brake operation constitutes the maximum load on the valve train system, that the cylinder pressure, with the cylinder at the compression stroke upper dead center, rises in proportion to a rise in the engine rpm, and that the load on the valve train system is at its maximum when the exhaust valve opens by brake operation. By examining the conditions whereunder a real vehicle was allowed to run, it has been found that the brake is applied approximately four times more often when the vehicle runs in a city area than on an expressway and that when running on the expressway the ...
1995-04-20
UK PubMed Central (United Kingdom)
BackgroundLung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently,...Full Text Available
Decrease in dust content and removal of sludge during drilling ascending shafts in coal
Energy Technology Data Exchange (ETDEWEB)
Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.
1983-01-01
UK PubMed Central (United Kingdom)
We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available
...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...
2009-07-01
International Nuclear Information System (INIS)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...
Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods
Energy Technology Data Exchange (ETDEWEB)
Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.
1996-12-31
Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A
Energy Technology Data Exchange (ETDEWEB)
Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)
1986-10-01
Energy Technology Data Exchange (ETDEWEB)
Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.
2009-07-01
Freeze protection valve and system
Energy Technology Data Exchange (ETDEWEB)
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
1985-12-10
Radiation risk in diagnostic radiology
International Nuclear Information System (INIS)
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
1984-01-01
The evaluation of risks from radiation
International Nuclear Information System (INIS)
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
1977-01-01
Energy Technology Data Exchange (ETDEWEB)
This report documents the technical basis by which the workplace air monitoring and sampling program is operated in the 324 and 327 Buildings.
2000-01-17
Somatic effects in nuclear medicine and radiology
International Nuclear Information System (INIS)
Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.
1999-01-01
International Nuclear Information System (INIS)
2004 p. 79-80 Poland Jastrzebski, T. Klinika Chirurgii Onkologicznej, Akademia
Radiological Source Localisation
... The goal of filtering (the sequential Bayesian ... 5] and the unscented Kalman filter (UKF) [16 ... set of deterministically chosen sample (or sigma) points. ...
2007-07-01
Non-opaque soft tissue foreign body: sonographic findings
UK PubMed Central (United Kingdom)
BackgroundSoft tissue foreign bodies are a common cause of orthopedic consultation in emergency departments. It is difficult to confirm their existence because conventional radiology...Full Text Available
Loss of Skeletal Calcium by Patients on Maintenance Dialysis
UK PubMed Central (United Kingdom)
Direct radiological measurements of the mineral content of femoral bone were performed in 13 patients on maintenance dialysis. They were found to be sufficiently sensitive to be used for monitoring,...Full Text Available
1970-08-29
Energy Technology Data Exchange (ETDEWEB)
The Seabed Disposal Project (SDP) was evaluating the technical feasibility of high-level nuclear waste disposal in deep ocean sediments. Working standards were needed for risk assessments, evaluation of alternative designs, sensitivity studies, and conceptual design guidelines. This report completes a three part program to develop radiological standards for the feasibility phase of the SDP. The characteristics of subseabed disposal and how they affect the selection of standards are discussed. General radiological protection standards are reviewed, along with some new methods, and a systematic approach to developing standards is presented. The selected interim radiological standards for the SDP and the reasons for their selection are given. These standards have no legal or regulatory status and will be replaced or modified by regulatory agencies if subseabed disposal is implemented. 56 refs., 29 figs., 15 tabs.
1997-06-01
Energy Technology Data Exchange (ETDEWEB)
The gastrointestinal transit was studied in 20 patients with loop transverse colostomies and previously normal colons. This analysis was performed through radiological observation of progression of 20 radiopaque pellets and measurements of its transit time in the various segments of the digestive tract. An evaluation of other related clinical and radiological events was carried out sentimentality's. In order to better understand the influence of the surgical procedure, the study was performed under similar dietary and supportive care conditions and standard radiological studies before and after the re-establishment of transit, thus enabling a comparison with the same individual. (author)
1988-07-01
Cost Sensitivity Analysis for Radiology Department Planning
UK PubMed Central (United Kingdom)
Two complementary computer programs have been developed for forecasting the demands and evaluating the costs of proposed radiographic facilities. The models are employed here in analyses of the sensitivity...Full Text Available
1971-01-01
Computed tomography of head in Clinic Pediatrics
Energy Technology Data Exchange (ETDEWEB)
138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.
1982-02-01
International Nuclear Information System (INIS)
Nuclear and other radioactive materials may get smuggled into the country aimed at malicious acts. Radioactive material detected accidentally or during inspection at the entry points/national borders may indicate illicit trafficking for the purpose of nuclear/radiological terrorism. As country requires prevention and preparedness for response to these malicious acts, nuclear forensic techniques are to be developed incorporating radiological safety aspects. Nuclear forensics helps in determining the origin, intended use, legal owner and the smuggled route etc. by using fingerprinting as well as comparison with reference data. The suggested sequence of methods for analysis of radioactive material/samples will be radiological assessment, physical characterization, traditional forensic analysis, isotope analysis along with elemental/chemical analysis
2010-11-15
Bone scanning in Ewing's sarcoma
International Nuclear Information System (INIS)
In eight patients with Ewing's sarcoma bone scans were performed using "9"9"mTc-MDP. This procedure rendered possible the diagnosis of clinically or radiologically silent metastases. (orig.).
A.C.R.O. activity report 2006; A.C.R.O. rapport d'activite 2006
Energy Technology Data Exchange (ETDEWEB)
This association participated in different working groups: North Cotentin radioecology group, groups of expertise on the uranium mines of Limousin, executive committee for the management of the post accidental phase of a nuclear accident or a radiological emergency situation, radioactive waste management, radiological surveillance of the territory, radiation protection mission by the Asn, radiological surveillance of the environment of the Chinon nuclear power plant, study of the presence of {sup 235}U around the site of Brennilis, study of the radioactive waste management at the Manche plant, radiological surveillance of the Cyceron cyclotron at Caen, Aurengo commission on the consequences in France of the Chernobylsk accident. Actions of information, regular publications, meeting with public are also a part of the work of this association. (N.C.)
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
This report discusses environmental surveillance activities conducted on the Nevada Test Site during the first calendar quarter of 1996. Surveillance activities included collection and analysis of air, noble gas, tritiated water vapor, and other water samples. Samples were analyzed for both radiological and non-radiological effluents.
1996-11-01
Patient doses from medical uses of x-rays
International Nuclear Information System (INIS)
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
1981-01-01
International Nuclear Information System (INIS)
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
1984-01-01
Intrahepatic cholangiocarcinoma presenting as liver abscess: report of two cases
International Nuclear Information System (INIS)
Intrahepatic cholangiocarcinoma is the second most common primary malignant hepatic neoplasm. We describe two cases of intrahepatic cholangiocarcinoma which initially presented as liver abscess both clinically and radiologically. Mucin-hypersecretion from the tumor cells and extensive necrosis or secondary bacterial infection was responsible for the radiologic appearance of a liver abscess.=20
1998-10-01
Health physics, safety and medical services report for 1989
Energy Technology Data Exchange (ETDEWEB)
The Health Physics, Safety and Medical Services Report for Harwell Laboratory for 1989 includes data on the monitoring of the working environment, personnel monitoring, radiological incidents, disposal of radioactive waste and protection of the public. Work on emergency planning, non-radiological health and safety, occupational hygiene, operations support is also discussed. Finally the medical services available and the medical examinations performed are described. (UK).
1990-09-01
ALARA Center of Technology -- resource guide
Energy Technology Data Exchange (ETDEWEB)
The purpose is to provide a source of information that can be used to assist personnel in the planning, training, and execution of radiological work using the principles of ALARA. This document is not intended to replace HNF or WHC Control Manual requirements. The ALARA Tools-List provides detailed information on the use and procurement of engineered controls, mockup training guidelines, and good radiological work practices that have been proven to be ALARA.
1998-02-05
Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4
International Nuclear Information System (INIS)
Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable ...
2006-11-13
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
Energy Technology Data Exchange (ETDEWEB)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.
2008-10-15
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
International Nuclear Information System (INIS)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.
2008-10-01
Liquid zone system events at Wolsong Unit 2
International Nuclear Information System (INIS)
On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) ...
1998-09-07
Dynamic load in suppression pool during BWR main steam safety relief valve actuation
International Nuclear Information System (INIS)
BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure with jet deflector were installed. The test plan and the test result with an actual ...
1979-01-01
CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25
International Nuclear Information System (INIS)
The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable ...
1986-06-09
Energy Technology Data Exchange (ETDEWEB)
Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: ...
2000-02-01
Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713
2004-12-01
Special features of control and protection for large saturated steam turbines
International Nuclear Information System (INIS)
For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).
Liquid level control system of fast reactor secondary cooling system
International Nuclear Information System (INIS)
Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).
Integrity of feedwater and main steam piping in KWU light water reactor plants
Energy Technology Data Exchange (ETDEWEB)
New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.
1986-07-01
International Nuclear Information System (INIS)
Presented in this report are the quantitative and qualitative aspects of the more than 5,800 applications of Grafoil on-plant. The subject all-graphite product was originally made by the Union Carbide Corporation. Its utilization in the forms of valve packing, gasketing and sealant tapes for leak repair and prevention on-plant since March 1970 is marked with typical zero-leak results. For all practical purposes, the successful results with Grafoil implementation indicate an unqualified control of leakage problems that began in 1967 with the V-11 and V-12 valves in the primary system of N Reactor. Meaningfully, the accruals of savings with existing and future applications shall continue to be incalculable in personnel exposure, maintenance, and capital. Inherent in the savings are the devised methodology and innovative developments coordinately employed in resolving the leak repair problems.
International Nuclear Information System (INIS)
The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.
Energy Technology Data Exchange (ETDEWEB)
The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.
1995-09-01
Development and application of a diaphragm micro-pump with piezoelectric device
British Library Electronic Table of Contents (United Kingdom)
In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...
2008-01-01
Cooling device for impurity removal device in thermonuclear devices
International Nuclear Information System (INIS)
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).
1983-08-26
A vortex valve ejector combination for fluidic two diode pumps
International Nuclear Information System (INIS)
Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).
Radiological hazards following a nuclear emergency
International Nuclear Information System (INIS)
Following the 1986 Chernobyl accident there was an understandable increase in public interest in nuclear accidents and emergency planning for them. It became clear that the broad nature, timing and scale of the radiological hazard presented by such accidents was, however, little understood. This Paper sets out in simple terms the basic features of the radiological hazard to persons in the vicinity of a nuclear power plant should a serious accident occur. The Paper starts by stressing the difference between faults -events that may occur relatively frequently - and accidents -unplanned releases of radioactivity that are by design extremely unlikely events. The Paper examines the significance of different exposure pathways and relates them to the protective measures (countermeasures) that may be taken. These countermeasures include sheltering, evacuation and the consumption of stable iodine tablets. The Paper illustrates the effectiveness of these ...
International Nuclear Information System (INIS)
In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.
2008-10-15
Low-level radioactive waste disposal in the oceans
Energy Technology Data Exchange (ETDEWEB)
A strategy for the management of the disposal of low-level radioactive wastes into coastal zones and ocean waters has developed over the past three decades. While there has been a substantial increase in the number of international and required agreements there has also been a concomitant improvement in our understanding of the ocean and the processes at work within it. This has allowed more rigorous and reliable assessments to be made of the radiological consequences. With the continued development of basic guidelines of radiological protection by the International Commission on Radiological Protection (ICRP) methodologies have been formulated to derive the fundamental scientific requirement - the relationship between disposal or release rate to the ocean and the resultant radiation dose to exposed human populations.
1983-04-01
What Parents Should Know about Medical Radiation Safety in Interventional Radiology
... Amount Background Radiation Blood vessel central line, PICC (peripherally inserted central catheter) or port placement, simple 0.4 mSv ...
International Nuclear Information System (INIS)
... Technology; Warsaw (Poland) 978-83-909690-8-4 221 p. RADIOLOGY AND
2008-09-15
Subtle Radiological Features of Splenic Avulsion following Abdominal Trauma
UK PubMed Central (United Kingdom)
Splenic trauma in children following blunt abdominal injury is usually treated by nonoperative management (NOM). Splenectomy following abdominal trauma is rare in children. NOM is successful as in the...Full Text Available
2010-01-01
SHIPBOARD RADIOLOGICAL - COUNTERMEASURE ...
... H1+80 Remaining H +82 Remaining H+56 IlemaJntng ,H+77 Remaining. Aa pct c/m pct mr/hr pet mr/hr pet ... mr/hr avg. pct c/rnh pt pa pct ...
1959-01-30
Review: Interventional radiology in peripheral vascular disease
UK PubMed Central (United Kingdom)
Peripheral vascular diseases (PVD) are referred to as diseases affecting the blood vessels other than the heart and the brain. Interventional endovascular treatment whenever feasible has become the...Full Text Available
2008-05-01
Energy Technology Data Exchange (ETDEWEB)
The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation participates in radiation protection and allows to make sure that ...
2007-07-01
UK PubMed Central (United Kingdom)
Percutaneous endoscopic lumbar discectomy (PELD) for migrated disc herniations is technically demanding due to the absence of the technical guideline. The purposes of this study were to propose a radiologic...Full Text Available
2007-03-01
Parathyroid glands tumors radionuclear imaging
International Nuclear Information System (INIS)
The purpose of work - to estimate opportunities of scintigraphy using "9"9"mTc-MIBI, her necessities and demerits in parathyroid glands adenoma, also to compare her results to conclusions of other radiological methods and results of research of an operational fabric. (author)
UK PubMed Central (United Kingdom)
The objective of this article is to evaluate two-year clinical and radiological follow-up results for patients who were treated with microdiscectomy and posterior dynamic transpedicular stabilisation...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.
1981-03-01
Extraosseous Ewing's sarcoma: review of a case
International Nuclear Information System (INIS)
Extraosseous Ewing's sarcoma (EES) is an uncommon lesion included in the group of soft tissue tumors. We present a case in a 19-year-old woman in which the diagnosis was not initially suspected because of the absence of clinical and radiological evidence. (Author).
Ewing's sarcoma: a neuroectodermal tumor of the chest wall
International Nuclear Information System (INIS)
Ewing's sarcoma is the second most common malignant bone tumor in children and young adults. It is most prevalent between the ages of 10 and 15 years. There are present two cases of Ewing's sarcoma of the chest wall. The clinical, radiological and pathological features are described and the therapeutic options are discussed. (Author)
Ewing's sarcoma presenting as a solitary cyst
International Nuclear Information System (INIS)
This case describes a 10-year-old girl who developed a Ewing's sarcoma in her proximal fibula. The radiologic features mimicked those of a unicameral bone cyst. The presence of pain and the atypical location led to a prompt biopsy and the correct diagnosis. The mechanism of this unusual radiographic presentation is discussed. (orig.)
2006-07-01
Diagnosis of Ewing's sarcoma in the thoracic spine - problems in differential diagnosis
International Nuclear Information System (INIS)
Spinal Ewing's sarcomas are rare and cause problems in differential diagnosis. The radiologic, nuclear medicine and CT findings in two children with histologically proven Ewing's sarcoma are presented and problems in differential diagnosis discussed. Biopsy should be done early. (orig.).
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
Cytological diagnosis of a rare case of solid pseudopapillary neoplasm of the pancreas
UK PubMed Central (United Kingdom)
A 23-year-old woman presented to our hospital with nonspecific pain in the abdomen. She underwent radiological investigations, which revealed a solid and cystic mass in the tail end of the pancreas....Full Text Available
2010-01-01
Conservative management of post traumatic thoraco diaphragmatico biliary fistula
UK PubMed Central (United Kingdom)
We report herein a case of thoraco diaphragmatico biliary fistula in a 24-year-old male who was managed conservatively with antibiotics and tube thoracostomy and had complete radiological clearance.
2010-10-01
UK PubMed Central (United Kingdom)
ObjectiveThe purpose of this study was to compare clinical and radiological outcomes of percutaneous endoscopic lumbar discectomy (PELD) and open lumbar microdiscectomy (OLM) for...Full Text Available
2009-12-01
Clinical and laboratory studies in patients with leprosy and enthesitis.
UK PubMed Central (United Kingdom)
In a combined clinical, radiological, and laboratory study of 77 patients throughout the leprosy spectrum, 10 patients had an enthesitis which has not been described previously as far as is known and...Full Text Available
1990-09-01
UK PubMed Central (United Kingdom)
Objective: To further delineate the clinicopathological and radiological features of solid pseudopapillary tumor (SPT) of the pancreas and summarize the surgical therapy strategy for this tumor. Methods:...Full Text Available
UK PubMed Central (United Kingdom)
To assess the effects of increasing the mineral content of parenteral nutrition solutions on the biochemical and radiological indicators of metabolic bone disease of prematurity 27 neonates who required...Full Text Available
1989-04-01
Energy Technology Data Exchange (ETDEWEB)
The work opened by the A.C.R.O. is in line with in an initiative of evaluation of the radiological quality of marine and continental waters of the Normandy coast. In this perspective, measures of radioactivity were made, not near an emissary (already very watched environment) but in more large scale because in marine environment, more than 640 km of coast are concerned. It was a question of supplying a representative assessment of the radioecological situation, for one year,of the marine environment (along the Normandy coast) and main streams which supplies it. (N.C.)
2000-09-15
Radiological performance assessment for the E-Area Vaults Disposal Facility
Energy Technology Data Exchange (ETDEWEB)
This report is the first revision to ``Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0.
2000-04-11
Energy Technology Data Exchange (ETDEWEB)
This report summarises work done on the SUCON Project during 1996-1999 (European Commission Contract No. FI4C-CT95-0001). The project has focused on three major objectives: 1) An assessment of the radiological consequences of the contamination of the South Urals and the Ob river system from the production of plutonium at 'Mayak', 2) The development of models to calculate doses to individuals and populations in the South Urals using environmental data, and 3) The intercomparison, harmonisation and standardisation of techniques used in dose reconstruction and specification of good practice in particular with regard to remedial measures. (au)
2000-12-01
Radiation exposure of patients and operators during interventional radiology
International Nuclear Information System (INIS)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
1986-01-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
Energy Technology Data Exchange (ETDEWEB)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-08-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
International Nuclear Information System (INIS)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-01-01
International Nuclear Information System (INIS)
Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)
2002-08-01
Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease
Energy Technology Data Exchange (ETDEWEB)
Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.
1983-03-01
Citizen involvement in radiological monitoring in their environment
Energy Technology Data Exchange (ETDEWEB)
This paper is intended to describe how the citizens who are living near power plants or more generally nuclear facilities can be involved in the radiological control of their environment. Through the experience of the last twenty years, the article describes the conditions of the progressive setting up of a non- governmental system of control to build its principles of action and put them into practice. Three kinds of actions are described, the first two dealing with the problems in France and the last one related to a post-accidental situation in the contaminated areas of Belarus. The conclusion underlines how important it is to encourage this kind of involvement in order to increase public awareness of nuclear activities and their consequences. (authors)
2005-07-01
Case report 437: Solitary (unicameral, simple) bone cyst of the scapula
Energy Technology Data Exchange (ETDEWEB)
A case has been presented of an expanding, aggressive bone cyst in the scapula of an 11-year-old girl. The lesion had the appearance of a highly aggressive, cyst-like disorder that appeared to be benign. Biopsy and histological preparation confirmed the presence of a solitary bone cyst. The clinical, radiological, and pathological criteria associated with a solitary bone cyst, particularly in the scapula, were discussed and the literature was reviewed. The differential diagnosis was stressed and a number of examples of scapular lesions was presented radiologically, particularly lesions that might be confused with solitary bone cyst. (orig./SHA).
1987-08-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of the 2003 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.
2001-02-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of the 2001 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct and scattered radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.
2002-02-01
A somatic dose index for diagnostic radiology
International Nuclear Information System (INIS)
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
1978-01-01
Energy Technology Data Exchange (ETDEWEB)
The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue ...
1995-07-01
The safety concept of public gas supply in Germany
Energy Technology Data Exchange (ETDEWEB)
The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)
1997-09-01
The potential of power fluidics for plant protection
International Nuclear Information System (INIS)
The possibility of using Direct Flow Control (DFC) to avoid catastrophic accidents due to containment breaches in chemical plant is discussed. Recommendations are made for locating fluidic elements, and the effectiveness of simple DFC protection is analysed. More powerful methods of protection are outlined using spin diversion and the complementary properties of fluidic and conventional valves are exploited. (author).
Energy Technology Data Exchange (ETDEWEB)
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)
1993-09-01
Power fluidics and the environment
International Nuclear Information System (INIS)
This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.
New safety device announced for nuclear power plants
International Nuclear Information System (INIS)
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
Method of controlling the coolant level in the cooling system of a nuclear power plant
International Nuclear Information System (INIS)
Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).
Energy Technology Data Exchange (ETDEWEB)
This patent describes a gas-diesel dual fuel engine apparatus having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode.
1986-08-05
Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen
Energy Technology Data Exchange (ETDEWEB)
Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).
1987-01-01
Device for advancing the base of a stoping unit
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.
1980-12-13
Energy Technology Data Exchange (ETDEWEB)
A general criterion has been suggested for deep geological repositories containing spent fuel - the repositories should impose no greater radiological risk than due to naturally occurring uranium deposits. The following analysis investigates the rationale of that suggestion and determines whether current expectations of spent-fuel repository performance are consistent with such a criterion. In this study, reference spent-fuel repositories were compared to natural uranium-ore deposits. Comparisons were based on intrinsic characteristics, such as radionuclide inventory, depth, proximity to aquifers, and regional distribution, and actual and potential radiological consequences that are now occurring from some ore deposits and that may eventually occur from repositories and other ore deposits. The comparison results show that the repositories are quite comparable to the natural ore deposits and, in some cases, present less ...
1980-09-01
Investigation of flora and fauna species of Lake Baikal by electron-probe microanalysis
International Nuclear Information System (INIS)
Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. ...
International Nuclear Information System (INIS)
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the modified RESF system ...
2006-11-13
The new BMW 4-cylinder engine in the 318i; Der neue BMW Vierzylindermotor im 318i
Energy Technology Data Exchange (ETDEWEB)
The BMW four-cylinder two-valve engine was first launched in September 1987 as a 1.8 l engine and was described in detail in [1]. After initial optimisation for model year 94, four years later the engine has undergone a complete technical revision. From model year 98, the four-cylinder two-valve engine with appropriate exhaust emission technology will satisfy the EU3 class for exhaust emissions. (orig.) [Deutsch] Der BMW Vierzylinder-Zweiventilmotor wurde im September 1987 als 1,8-l-Motor erstmals vorgestellt und in [1] ausfuehrlich beschrieben. Nach einer ersten Optimierungsueberarbeitung zum Modelljahr 1994 wurde nun eine grundlegende technische Ueberarbeitung vorgenommen. Der Vierzylindermotor mit Zweiventiltechnik erfuellt als Antriebsaggregat in Verbindung mit einer entsprechenden Abgastechnik bereits ab Modelljahr 1998 die EU 3-Stufe fuer Abgasemissionen. (orig.)
1998-05-01
Energy Technology Data Exchange (ETDEWEB)
The complete determination of stroke/throughput curves at steam turbines for arbitrary valve positions usually only follows after the fundamental layout of the control valves, of the possible nozzle segments and of the turbine blading. A general fundamental equation and some design norms based on it are presented which may serve already before a fluidic layout of the turbine in detail as an optimizing predetermination of the properties concerning pressure loss and control statics of the metering components in the admission area. (orig.) [Deutsch] Die vollstaendige Bestimmung der Hub-/Durchsatzkurven an Dampfturbinen fuer beliebige Ventilstellungen erfolgt ueblicherweise erst nach der Grundauslegung der Stellventile, etwaiger Duesensegmente und der Turbinenbeschaufelung. Es werden eine allgemeine Grundgleichung und einige auf ihr aufbauende Entwurfsregeln angegeben, die zu einer optimierenden Vorabbestimmung der druckverlustbezogenen ...
1997-06-01
Some medical applications of thermomechanically treated titanium nickelide
Energy Technology Data Exchange (ETDEWEB)
An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first ...
2001-11-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
Energy Technology Data Exchange (ETDEWEB)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.
2003-10-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
International Nuclear Information System (INIS)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.
2003-10-01
Modeling the internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
A flexible and computationally economical model of the internal combustion engine was developed for use on large digital computer systems. It is based on a system of ordinary differential equations for cylinder-averaged properties. The computer program is capable of multicycle calculations, with some parameters varying from cycle to cycle, and has restart capabilities. It can accommodate a broad spectrum of reactants, permits changes in physical properties, and offers a wide selection of alternative modeling functions without any reprogramming. It readily adapts to the amount of information available in a particular case because the model is in fact a hierarchy of five models. The models range from a simple model requiring only thermodynamic properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. Among its many features the model includes heat transfer, valve timing, ...
1985-03-01
Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement
British Library Electronic Table of Contents (United Kingdom)
BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...
2011-01-01
Fault detection and fault diagnosis system for engine; Engine no kosho yochi shindan system
Energy Technology Data Exchange (ETDEWEB)
The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and degradation of engine parts, it can transfer ...
1996-03-29
Establishment of Database Program for In-service Test Management in Nuclear Power Plants
International Nuclear Information System (INIS)
In-service Test (IST) of the nuclear power plant is very important to maintain the safety of the plants. The safety features of nuclear power plant are based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves. Because of the importance of the IST, most of nuclear power plants should designate the IST department and personnel. Because the nuclear power plants of Korea have several types and the designs and operations are different from each other, the methods and experiences are various for the management of the IST program. However, there are no medium to communicate with each other and exchange the tips and information about IST program and education and discussion would be required to apply a consistent code. The nature of the IST Standardization Management Data Base (SMDB) is to exchange opinions and documents about IST program and ...
2010-10-01
The objective of the program is to develop a domestic cooktop with low-NOx emissions and high efficiency. During the first two phases of the program, three design concepts were developed, and two versions of developmental prototypes using the IR-Jet approach were fabricated and tested. The third phase was initiated to address the design issues of burner turndown and modulation and to conduct the field test of a prototype with one IR-Jet and three conventional burners. Two prototypes containing one IR-Jet and three conventional burners and utilizing blower speed control for air/gas modulation were fabricated. One unit employed a brushless dc motor and the other a 2-pole ac motor. The ac motor prototype was field tested. Field testing showed the need for a mechanical air/gas valve for modulation and for a 1500 Btu/hr simmer setting. A 4-inch-diameter stepped-tile configuration provided input rates from 1500 to 8000 Btu/hr. A manufacturer, Copreci of Spain, started ...
1987-06-01
Energy Technology Data Exchange (ETDEWEB)
To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and ...
1991-10-15
Combustion system for dual fuel engine
Energy Technology Data Exchange (ETDEWEB)
This patent describes in an dual gas-liquid fuel four cycle engine having cylinders and wherein each cylinder is operatively connected thereto and each cylinder has a piston, two inlet valves, two exhaust valves and a first liquid fuel injector. It comprises: at least one fuel torch cell operatively connected to at least one cylinder, the torch cell having a torch cell nozzle at one end thereof and the other end having appropriate means to connect the torch cell to a fuel supply, a second fuel injector mounted in the torch cell at a predetermined angle to an axis of the torch cell, the torch cell defining an auto-ignition chamber, the second fuel injector being in operative communication with the auto-ignition chamber by an injector nozzle passageway, the injector nozzle passageway entering the auto-ignition chamber at a predetermined angle relative to the axis, and a torch nozzle passage connecting the auto-ignition chamber with the cylinder ...
1990-10-30
Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event
International Nuclear Information System (INIS)
In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle heat transfer model, decay heat model and MOV(Motor Operated ...
2001-10-01
Summary of comments received from workshops on radiological criteria for decommissioning
Energy Technology Data Exchange (ETDEWEB)
The Nuclear Regulatory Commission (NRC) is conducting an enhanced participatory rulemaking to establish radiological criteria for site cleanup and decommissioning of NRC-licensed facilities. Open public meetings were held during 1993 in Chicago, IL, San Francisco, CA, Boston, MA, Dallas, TX, Philadelphia, PA, Atlanta, GA, and Washington, DC. Interested parties were invited to provide input on the rulemaking issues before the NRC staff develops a draft proposed rule. This report summarizes 3,635 comments categorized from transcripts of the seven workshops and 1,677 comments from 100 NRC docketed letters from individuals and organizations. No analysis or response to the comments is included. The comments reflect a broad spectrum of viewpoints on the issues related to radiological criteria for site cleanup and decommissioning. The NRC also held public meetings on the scope of the Generic Environmental Impact Statement (GEIS) during July 1993. The ...
1994-01-01
Role of CT in the assessment of the volume to be irradiated in bone metastases
International Nuclear Information System (INIS)
In the Department of Radiology of Catholic University S. Cuore in Rome, a review was made of 342 CT examinations with a view towards optimizing the therapeutic planning in patients affected by bone metastases. All patients were submitted to radiological positioning and then to CT evaluation in order to assess the volume to be treated. In 224 cases it was not necessary to perform wide CT examination (3-5 standard tomograms being enough, 2 of which at the superior and inferior margins of the planned field). In the second group of 118 patients it was necessary to perform CT (serial axial scans) - increasing by 1-1.5 cm - up to the superior and inferior margins of the lesion. The existence of 2 types of lesions was confirmed: those involving mainly bony structures and those infiltrating the soft tissues. CT evaluation allowed the definition of the target volume to the real extension of the lesion in 14% of the whole of cases, while in the group of ...
1988-01-01
Radiological aspects of the usability of red mud as building material additive
International Nuclear Information System (INIS)
Several researchers have examined and achieved favourable results in connection with the building industry's use of red mud extracted in large quantities from the processing of bauxite. These days more and more precedence is being given to limiting the radiological dose to the population. In this study carried out in Hungary, the use of red mud, bauxite, and clay additives recommended for the production of special cements, were examined from a radiological aspect. "2"2"6Ra and "2"3"2Th activity concentrations measured in Hungarian bauxite, red mud and clay samples were significantly similar with the levels for such raw materials mentioned in international literature. Taking radiation protection aspects into consideration, none of these products can be directly used for building construction. Taking Hungarian and international values into consideration, a small amount of red mud, not exceeding 15% could be used for brick production, for example ...
2008-02-11
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...
2009-10-15
Computed tomography of the orbit
Energy Technology Data Exchange (ETDEWEB)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, ...
1981-01-01
An aerial radiological survey of the Oak Ridge Reservation, Oak Ridge, Tennessee
International Nuclear Information System (INIS)
An aerial radiological survey of the Oak Ridge Reservation (ORR) and surrounding area in Oak Ridge, Tennessee, was conducted during the period March 30 to April 14,1992. The purpose of the survey was to measure and document the terrestrial radiological environment of the Oak Ridge Reservation for use in environmental management programs and emergency response planning. The aerial survey was flown at an altitude of 150 feet (46 meters) along a series of parallel lines 250 feet (76 meters) apart and included X-10 (Oak Ridge National Laboratory), K-25 (former Gaseous Diffusion Plant), Y-12 (Weapons Production Plant), the Freels Bend Area and Oak Ridge Institute for Science and Education, the East Fork Poplar Creek (100-year floodplain extending from K-25 to Y-12), Elza Gate (former uranium ore storage site located in the city of Oak Ridge), Parcel A, the Clinch River (river banks extending from Melton Hill Dam to the city of Kingston), and the CSX ...
1993-06-22
The Bevatron liquid nitrogen circulation system
A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.
1987-03-01
Testing of the 1-MWth bench-model cavity-receiver steam generator
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)
Energy Technology Data Exchange (ETDEWEB)
In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).
1989-09-01
Energy Technology Data Exchange (ETDEWEB)
Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.
1982-04-01
Method for limiting scram discharge water
International Nuclear Information System (INIS)
Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).
Method and apparatus for operation of a dual fuel compression ignition combustion engine
Energy Technology Data Exchange (ETDEWEB)
A dual fuel engine control system for controlling the power output of a dual fuel compression ignition engine. The engine includes mixing means for combining an oxidizer and a primary fuel at a substantially constant ratio of oxidizer to primary fuel. The power output of the engine is controlled through the use of a throttle valve controlling the quantity of combustible mixture delivered to the combustion chamber. The fuel control system minimizes the quantity of ignition fuel required by controlling the quantity of combustible mixture rather than the fuel of air ratio. (author) figs.
1994-03-03
Isolated laevocardia and corrected transposition of the great vessels with total situs inversus
International Nuclear Information System (INIS)
Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).
Improvement of assessment methodology for fluid flow characteristics of passive flow control device
International Nuclear Information System (INIS)
The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.
2002-10-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1989-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1988-01-01
Evolution of ASTEC V1.2 rev.1 code for WWER-1000 reactors/SBO sequence
International Nuclear Information System (INIS)
In this paper a comparison between calculations of severe accidents occurred from WWER-1000 with ASTEC code specified for an event of full unloading with relief valves stuck opened with no hydroaccumulators intervention is presented. The purpose of the analyses provided is to present the relationship between the improvements of the actual version (ASTEC Vl.2 rev. 1) and ASTEC V1.1 p2 like: code modifications, incoming data improvements. Such discrepancies are to be examined. Case by case suggestions for ASTEC improvements are to be provided.
2006-06-14
Error evaluation of the linearized equation of servo valve in hydraulic control systems
International Nuclear Information System (INIS)
In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.
2001-11-01
Development of electro-optical instrumentation for annular two-phase flow studies
International Nuclear Information System (INIS)
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)
2000-05-10
Autogenous electrolyte, non-pyrolytically produced solid capacitor structure
Energy Technology Data Exchange (ETDEWEB)
A solid electrolytic capacitor having a solid electrolyte comprising manganese dioxide dispersed in an aromatic polyamide capable of further cure to form polyimide linkages, the solid electrolyte being disposed between a first electrode made of valve metal covered by an anodic oxide film and a second electrode opposite the first electrode. The electrolyte autogenously produces water, oxygen, and hydroxyl groups which act as healing substances and is not itself produced pyrolytically. Reduction of the manganese dioxide and the water molecules released by formation of imide linkages result in substantially improved self-healing of anodic dielectric layer defects.
1998-01-01
The role of interventional radiology in management of patients with end-stage renal disease
Energy Technology Data Exchange (ETDEWEB)
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as ...
2003-05-01
International forensics cooperation: reviewing frameworks, goals and capabilities
International Nuclear Information System (INIS)
Full text: There have been many recent calls for increased international cooperation in the field of nuclear forensics. While much is already being done, for example by the International Technical Working Group on Nuclear Smuggling and International Atomic Energy Agency, more effort is needed as cooperation on real-world incidents is often ad hoc. As a result, incidents - particularly diversions of nuclear material - are not effectively investigated, and opportunities to keep dangerous materials out of the hands of terrorists or proliferators are missed. Forensics techniques can be used to investigate many types of incidents involving illicit uses of nuclear or radiological material, but the need for cooperation can be seen most clearly in the area of illicit trafficking where collaboration is needed now. Here governments have had some success interdicting smuggled material but diversions are not usually effectively investigated. Forensics cooperation is often cast ...
Summary of ACSL Simulations of the MSRE Auxiliary Charcoal Bed Vacuum System
Energy Technology Data Exchange (ETDEWEB)
The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance acceptable; (1) Remove valve PCV4. (2) Modify the flow controllers ...
2000-10-26
The NCRP wound model: development and application.
The US National Council on Radiation Protection and Measurements, in collaboration with the International Commission on Radiological Protection, has been developing a biokinetic and dosimetric model for radionuclide-contaminated wounds. The finalised model is described briefly in this paper, together with the scientific basis and application. The multicompartment model uses first-order linear biokinetics to describe the retention and clearance of a radionuclide deposited in a wound site using seven default retention categories. Examples using plutonium nitrate in colloidal form and uranium in metal fragments show the behaviour of the less soluble forms of radionuclides in wounds, in which long-term retention is predicted. Using uranium as an example, the wound model is coupled to a uranium International Commission on Radiological Protection systemic model to predict urinary excretion patterns for different physicochemical forms of uranium. The ...
2007-08-31
Review of Regulatory Quality Assurance Requirements for the Operation of Nuclear R and D Facilities
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation, including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently, nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/ contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. In this paper, the context of amended Atomic Energy laws were reviewed to confirm quality assurance measures and identify additional QA activities, if any, that is required by the amendment
2005-10-27
Radiological operating experience at FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.
1987-04-22
International Nuclear Information System (INIS)
Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).
1986-09-24
Energy Technology Data Exchange (ETDEWEB)
The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiation dosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in nuclear medicine and fusion reactor technology, and some of ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
RESRAD was one of the multimedia models selected by the US Nuclear Regulatory Commission (NRC) to include in its workshop on radiation dose modeling and demonstration of compliance with the radiological criteria for license termination. This paper is a summary of the presentation made at the workshop and focuses on the 10 questions the NRC distributed to all participants prior to the workshop. The code selection criteria, which were solicited by the NRC, for demonstrating compliance with the license termination rule are also included. Among the RESRAD family of codes, RESRAD and RESRAD-BUILD are designed for evaluating radiological contamination in soils and in buildings. Many documents have been published to support the use of these codes. This paper focuses on these two codes. The pathways considered, the databases and parameters used, quality control and quality assurance, benchmarking, verification and validation of these codes, and ...
1998-05-01
International Nuclear Information System (INIS)
The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.
Energy Technology Data Exchange (ETDEWEB)
Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)
2007-11-15
Design modifications in radiation monitoring system at Tarapur Atomic Power Station 3 and 4
International Nuclear Information System (INIS)
Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)
2006-11-13
Computed Tomography of the spine in multiple myeloma
International Nuclear Information System (INIS)
Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.
1988-01-01
Cleansing methodology of sites and its applications
International Nuclear Information System (INIS)
The Commissariat a l'Energie Atomique (CEA, French Atomic Energy Commission) has set up over the last 10 years an innovative methodology aiming at characterizing radiological contaminations. The application of the latter relies on various tools such as expertise vehicles with impressive detection performances (VEgAS) and recently developed software platform called Kartotrak. A Geographic Information System tailored to radiological needs constitutes the heart of the platform; it is surrounded by several modules aiming at sampling optimization (Stratege), data analysis and geostatistical modeling (Krigeo), real-time monitoring (Kartotrak- RT) and validation of cleaning efficiency (Pescar). This paper presents the different tools which provide exhaustive instruments for the follow-up of decontamination projects, from doubt removal to the verification of the decontamination process. (authors)
2009-10-12
Chernobyl accident: the crisis of the international radiation community
Energy Technology Data Exchange (ETDEWEB)
The information given in the present report about the Chernobyl accident and its radiological consequences indicates a serious crisis of the international radiation community. The following signs of this crises can be discerned: The international radiation community did not recognize the real reasons of the accident for a long time. It could not make a correct assessment of the damage to the thyroid of the affected populations of Belarus, Russia and the Ukraine. Up to present time it rejects the reliable data on hereditary malformations. It is not able to accept reliable data on the increase in the incidence in all categories of people affected by the Chernobyl accident. The international radiation community supported the Soviet authorities in their attempts to play down the radiological consequences of the Chernobyl accident for a long time. (author)
1998-03-01
Assessment of radiological safety of Wolsung site at site boundary considering crack impact
British Library Electronic Table of Contents (United Kingdom)
The number of spent fuel storage facilities in the world continues to increase because of "Wait and See" policies and delay of a permanent disposal plan. The temporary spent fuel storage concept is changing to a pre-disposal storage concept. Strengthened safety concepts are required for expanded spent fuel storage facilities and sites. The Korea Hydro and Nuclear Power Company is planning to construct a reinforced concrete MACSTOR-400 facility at Wolsung. In concrete dry spent fuel storage structures, cracks can occur due to radiant heat and environmental chloride. The likelihood of cracking increases over time. Research on changes in shielding performance from one collinear crack in the surface of a concrete facility has been carried out. However there is no research about public radiolog...
2010-01-01
[Enzymatic pancreatogenic omental bursitis].
The most common causes of omental sac collections (OSC) are necrotic pancreatitis (90%) and pancreatic trauma (10%). Acute OSC is a form of local peritonitis in acute pancreatitis, subacute OSC are caused by internal pancreatic fistulas. The clinical and radiological signs, enzymatic activity of the exudate, morphological features of peritonitis were investigated. Treatment of acute OSC included conservative measures, of subacute OSC-surgical procedures. PMID:9163152
1996-01-01
Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor
International Nuclear Information System (INIS)
Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)
Tumorigenic and tumoricidal actions of ionizing radiations
Energy Technology Data Exchange (ETDEWEB)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
1983-01-01
Trial of using computer tomography in the diagnosis of mediastinal diseases in children
Energy Technology Data Exchange (ETDEWEB)
In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.
1981-01-01
Transfer of chemical elements to breast milk
International Nuclear Information System (INIS)
The project is intended to yield information on the transfer factors describing the transfer of ingested radionuclides to breast milk for the following elements: antimony, cerium, chromium, cobalt, gallium, lanthanum, molybdenum, niobium, radium, ruthenium, silver, thorium, titanium, and uranium. Those yet unknown or poorly known transfer factors are required in order to be able to develop a reliable model for description and assessment of the transfer of the radionuclides and the possibly resulting hazardous doses to infants, and for subsequent formulation of recommendations for radiological protection of the population. (orig./CB)
1999-08-01
The role of imaging in the choice of correct treatment of unstable thoraco-lumbar fractures
International Nuclear Information System (INIS)
The concept of unstable burst fracture has been discussed since over 50 years and this injury has received much attention in the literature as regards its radiological diagnosis and clinical treatment. The purpose of this article is to review the way we use imaging to diagnose the injury and to guide treatment.
2006-09-01
International Nuclear Information System (INIS)
The slow or stagnant rate of nuclear power generation development in many developed countries over the last two decades has resulted in a significant shortage in the population of mid-career nuclear industry professionals. This shortage is even more pronounced in some specific areas of expertise such as radiological protection, waste management and decommissioning. This situation has occurred at a time when the renaissance of nuclear power and the globalization of the nuclear industry are steadily gaining momentum and when the industry's involvement in international and national debates in these three fields of expertise (and the industry's impact on these debates) is of vital importance. This paper presents the World Nuclear Association (WNA) approach to building and enhancing worldwide industry cooperation in radiological protection, waste management and decommissioning, which is manifested through the activities of the two WNA working groups ...
The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report
Energy Technology Data Exchange (ETDEWEB)
A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI.
2010-01-15
The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report
International Nuclear Information System (INIS)
A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI
2010-01-01
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
Serious radiation accidents and the radiological impact on agriculture
International Nuclear Information System (INIS)
The consumption of food products obtained in areas subjected to radioactive contamination as a consequence of a radiation accident appears to be the most significant source of irradiation for the population. At the same time, this route can be regulated very effectively. The regularities of contamination of agricultural production, peculiar features of internal dose formation in the population and the effectiveness of countermeasures in agriculture have been analysed using the experience of two major accidents in the former USSR - in the South Urals (Kyshtym accident) in 1957, and at the Chernobyl NPP in 1986. (Author).
Screen-film-combinations for radiography - present and future spectrum of application
Energy Technology Data Exchange (ETDEWEB)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.
1985-01-01
Screen-film-combinations for radiography - present and future spectrum of application
International Nuclear Information System (INIS)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).
Energy Technology Data Exchange (ETDEWEB)
The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe) [Deutsch] Das vorliegende Lehrbuch, das sich vor allem an das technische Personal und an Strahlenschutzbeauftragte wendet, unterrichtet ueber die derzeit gueltigen Bestimmungen der Roentgenverordnung, die Anwendung von Roentgenstrahlen, ueber Qualitaetssicherung, die Organisation der Filmverarbeitung sowie ueber die Anforderungen an ...
1996-12-31
Radiological diagnosis of lesions of intervertebral discs
International Nuclear Information System (INIS)
During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.)
2003-03-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
The Formerly Utilized Sites Remedial Action Program (FUSRAP) is to evaluate the radiological conditions at former MED-US AEC sites. Purpose of the Ocean FUSRAP program is to assess the feasibility of ocean disposal of FUSRAP waste which contains trace natural radioactive materials. This paper presents soil characterization information on the Middlesex, NJ, Sampling Plant site, and reports preliminary ocean dispersion calculations. (DLC)
1982-01-01
New concept to optimize emergency diagnoses in patients with multiple injuries
International Nuclear Information System (INIS)
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
Isolated dextrogastria: report of two cases
International Nuclear Information System (INIS)
Isolated situs inversus of the stomach with otherwise normal position of the thoracic and abdominal viscera is an extremely rare anomaly occurring in two distinct forms. Because of its close relationship to the liver, the right-sided stomach may produce interesting and confusing changes in the liver scan. Two cases illustrate the radiologic features of the two principal types of isolated congenital dextrogastria and the effect of one type on the liver scan.
Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours
Energy Technology Data Exchange (ETDEWEB)
In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.
1980-03-01
Imaging findings of central nervous system neuroepithelial cysts
Energy Technology Data Exchange (ETDEWEB)
Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.
1998-05-01
International Nuclear Information System (INIS)
The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR imaging open the view at the fine structures of the mediastinum. ...
Downward penetration of hot UO/sub 2/ into basalt concrete
Energy Technology Data Exchange (ETDEWEB)
Following a postulated meltdown accident, the integrity of containment building structural material under attack by hot molten core debris and the safeguard of environment against radiological releases constitutes the final line of defense in PAHR safety assessment. Such assessment requires a good knowledge of UO/sub 2//interaction and penetration with different types of concrete. The present study focuses on the phenomena associated with core debris interaction/penetration with substrate basalt concrete.
1983-01-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
Domestic radon exposures in the UK
Energy Technology Data Exchange (ETDEWEB)
Radon in the home is the main source of exposure to ionising radiation for most people. In 1990 the National Radiological Protection Board issued revised advice to the United Kingdom Government on standards of protection against radon in the home. A description is offered of the survey work being undertaken by the Board which includes radiation measurements of thousands of homes in the United Kingdom. (author).
1991-09-01
Differential diagnosis of tumorous lesions in the iliac bone in children
Energy Technology Data Exchange (ETDEWEB)
The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.
1984-02-01
Development of a site-specific following accident dose assessment system
Energy Technology Data Exchange (ETDEWEB)
The objectives of this project to interface the site-specific real-time radiological dose assessment system FADAS(Following Accident Dose Assessment System) to CARE. In this study, the results of the field tracer experiments conducted on the Younggwang site have been analysed. And the experimental procedure on Ulchin site has been introduced. The environmental characteristics on Ulchin and Wolsung has been investigated.
1997-12-15
Development and application of a gamma scanning system for LLW and MLW packages
International Nuclear Information System (INIS)
The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.
1993-09-05
Cold Vacuum Drying (CVD) Facility Technical Safety Requirements
Energy Technology Data Exchange (ETDEWEB)
The Technical Safety Requirements (TSRs) for the Cold Vacuum Drying Facility define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation. Controls required for public safety, significant defense-in-depth, significant worker safety, and for maintaining radiological and toxicological consequences below risk evaluation guidelines are included.
1999-12-16
Chrondoblastoma of the patella
International Nuclear Information System (INIS)
This study reviews 16 cases of chondroblastoma of the patella which constitute mearly 6% of a large group of chondroblastomas scattered throughout the skeleton. Both radiologic and histologic appearances of chondroblastomas of the patella are indistinguishable from those of chondroblastomas arising in other sites. A reasonable differential diagnosis, including chondromalacia patella, is discussed together with important therapeutic considerations. (orig.).
UK PubMed Central (United Kingdom)
Chondrosarcomas are the most frequently occurring primary malignant chest wall tumors. Furthermore, the lungs serve as the most frequent sites for metastases. Pulmonary metastases from sarcomas usually...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
Niger is the second poorest country in the world but it has natural resources underground in the form of uranium ores deposits. This uranium is currently mined by two companies incorporated under Nigerian law: Somair and Cominak, operated by the principal shareholder Areva (through its subsidiary Cogema). After a presentation of Somair and Cominak key figures, this document details the working conditions and radiological protection, the environmentally friendly operations, the production traceability, the local economic development, the strengthening of the health care system and the development of the infrastructure. (A.L.B.)
2005-02-01
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The nint version of the licensing regulation for medical doctors (Approbation Regulation (AR)) sets a benchmark in terms of practical experience, interdigitation of preclinical and clinical studies, interdisciplinary approach, economic efficiency, independence of students, added new teaching and learning modalities, and ongoing evaluation of the progress of the medical students. It is the aim to implement these major points of the AR in a model course for diagnostic radiology and radiation protection within the scope of the Virtual University of Bavaria and test them in practice. Materials and Methods: In cooperation with residents and board certified radiologists, students developed the virtual course 'Web-Based Training (WBT) Radiology' in diagnostic radiology and radiation protection for students in the first clinical semester. A representative target group taken from the student body was asked ...
2004-06-01
International Nuclear Information System (INIS)
Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic ...
2002-09-23
REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.
Energy Technology Data Exchange (ETDEWEB)
Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam ...
1999-05-01
Tickover speed controller for car engines
Energy Technology Data Exchange (ETDEWEB)
In general, the tickover speed of a car engine is made sufficiently high, in order to permit an assumed maximum load to be taken from the engine at tickover. This setting of the tickover speed is usually done by stops in the fuel supply. Matching the actual load would lead to lower fuel consumption, without any danger of the engine stalling. The purpose of the invention is to provide a tickover speed controller, so that the tickover speed is adjusted by electronic control equipment, independently of the machine load. The fuel consumption on tickover is reduced and the emission of noxious substances is decreased. The electro-magnetic control of the throttle valve tickover setting is explained by extensive section drawings of the system. This process dispenses with the special tickover cams for a cold start.
1980-05-22
The influence of bowl offset on air motion in a direct injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
The influence of bowl offset on motored mean flow and turbulence in a direct injection diesel engine has been examined with the aid of a multi-dimensional flow code. Results are presented for three piston geometries. The bowl geometry of each piston was the same, while the offset between the bowl and the cylinder axis was varied from 0.0 to 9.6% of the bore. The swirl ratio at intake valve closing was also varied from 2.60 to 4.27. It was found that the angular momentum of the air at TDC was decreased by less than 8% when the bowl was offset. Nevertheless, the mean (squish and swirl) flows were strongly affected by the offset. In addition, the distribution of turbulent kinetic energy (predicted by the /delta/-e model) was modified. Moderate increases (10% or less) in mass averaged turbulence intensity at TDC with offset were observed.
1988-01-01
British Library Electronic Table of Contents (United Kingdom)
Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...
2011-01-01
Surge-line thermal stratification: Displacements and fatigue damage computations
Energy Technology Data Exchange (ETDEWEB)
Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. Alternative solutions for coping with ...
1989-01-01
Start safety apparatus for internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.
1986-09-09
Powertrain and apparatus using a continuously variable ratio transmission to improve fuel economy
Energy Technology Data Exchange (ETDEWEB)
An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are optimized to produce exceptional fuel economy.
1981-07-28
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
Natural radioactive materials in oil and gas industry
International Nuclear Information System (INIS)
Oil and gas production and processing operations sometimes cause naturally occurring radioactive materials (NORM) to accumulate at elevated concentrations in by-product waste streams. The sources of most of the radioactivity are isotopes of "2"3"8U and "2"3"2Th series, which are naturally present in the subsurface formations from which oil and gas are produced. NORM waste may cause problems in the operations of installations by plugging perforations, clogging tubular and valves then restricting flow. Therefore, plants or equipment have to be refurbished and decontaminated before reuse to avoid radioactive waste or surface contaminated object. There are two options for safe disposal of scale and sludge produced from NORM Descaling Facility : 1- Injection into an abandoned production well. 2- The construction of a near surface depository. These options are assumed to be environmental friendly disposal options. (author)
2010-03-01
Method of feeding a coolant into a reactor
International Nuclear Information System (INIS)
Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).
Measuring air movement locally in the combustion chambers of a direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
Measurements of smoke and NO emissions from a direct-injection diesel engine have shown that they are indeed influenced by inlet port design, even though the swirl numbers for the ports may be identical. The swirl numbers of the three ports used (tangential port, helical port and helical port with masked valve) were measured on a steady-state test rig using a paddle-wheel anemometer and impulse swirl meter. Flow measurements were carried out under motoring conditions with a constant-temperature, hot-wire anemometer. Is was possible to find a correlation between flow data and exhaust data as far as the in-cylinder air motion over a certain time interval is concerned.
1983-02-01
Energy Technology Data Exchange (ETDEWEB)
The performance of the gaseous fuel supply and its influence on hydrocarbon (HC) emissions of dual-fuel engines have been investigated. A new design of manifold respirators with mixers is also presented in the paper. The design of the gaseous fuel supply system has a great influence on HC emissions in the dual-fuel engine at light load. The problem of scavenging is discussed and solved by using the manifold respirators in the dual-fuel engine. It performs the function of retarding the gaseous fuel entry timing from the moment of intake valve opening, and its delaying effects have been measured and tested. Experimental results show that the manifold respirator gives the best performance in reducing HC emissions compared with a common pipe mixer and a respirator with bo miser. In addition, the mixing effects are sensitive to the mixer configuration. (Author)
2000-11-01
British Library Electronic Table of Contents (United Kingdom)
Tissue-engineered heart valves are prone to early structural deterioration. We hypothesize that cell?scaffold interaction and mechanical deformation results in upregulation of genes related to osteogenic/chondrogenic differentiation and thus changes extracellular matrix (ECM) composition in human bone marrow mesenchymal stem cell (hBMSC)-derived tissue-engineered grafts. hBMSC were expanded and seeded onto poly-glycolic acid/poly-lactic acid scaffold for 14 days. Seeded tissue-engineered constructs (TEC) were subjected to cyclic flexure for 24?h, whereas control TEC was maintained in roller bottles for the same duration. hBMSC, TEC, and mechanically deformed TEC were subjected to gene-array and histological analysis. Expression levels of RNA and/or protein markers related to chondrogenesis...
2011-01-01
Fuel injection control for diesel engine
Energy Technology Data Exchange (ETDEWEB)
A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.
1987-11-10
Friction in ultra-thin conjunction of valve seals of pressurised metered dose inhalers
British Library Electronic Table of Contents (United Kingdom)
In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...
2010-01-01
International Nuclear Information System (INIS)
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...
Development of electro-optical instrumentation for annular two-phase flow studies. [PWR
Energy Technology Data Exchange (ETDEWEB)
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
1981-05-01
Detection of intracardiac calcification using Fuji computed radiography
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
1986-01-01
International Nuclear Information System (INIS)
Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).
Energy Technology Data Exchange (ETDEWEB)
The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management tools. 1 ref., 1 tab., 4 figs.
1996-08-01
British Library Electronic Table of Contents (United Kingdom)
Here we present a revision of the fossil record of chitons (Mollusca, Polyplacophora) of Late Pleistocene and Holocene marine deposits of Uruguay and discuss their potential for palaeoenvironmental reconstruction. Chitons were recorded as isolated valves in bivalve- and gastropod-rich assemblages. They are represented by the species Chaetopleura angulata (Spengler), C. isabellei (d'Orbigny), C. asperrima (Gould) and Ischnochiton striolatus (Gray). The last two species are recorded for the first time as fossils not only in Uruguay but also in South America. Exclusively recorded for the Late Pleistocene is the warm water species I. striolatus, whose current southern range limit is located in Santa Catarina, Brazil. Higher temperatures than at present are inferred for the Uruguayan coast duri...
2011-01-01
Characterization and effect of using cotton methyl ester as fuel in a LHR diesel engine
International Nuclear Information System (INIS)
In the present study, surfaces of cylinder head, piston, exhaust and inlet valve of a four-stroke, direct injection, single cylinder diesel engine were coated with molybdenum (Mo) by plasma spray method. Thus, thermal barrier characteristic was brought to these parts. Variances in performance and emission values of cotton methyl ester and 2D fuel mixtures were studied in the ceramic coated and uncoated engines under the same running conditions. Performance (6.0% for specific fuel consumption) and emission values (up to 18.0% for CO, 8.0% for smoke density) of the test fuel were improved in the coated engine compared with the uncoated engine. NO_x increase (4.5%) with the increased temperatures expected in the coated engine.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).
1993-12-31
International Nuclear Information System (INIS)
The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).
1992-09-29
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Energy Technology Data Exchange (ETDEWEB)
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.
1985-07-03
An historical view of the pineal gland and mental disorders
British Library Electronic Table of Contents (United Kingdom)
Since Classical Antiquity numerous authors have linked the origin of some mental disorders to physical and functional changes in the pineal gland because of its attributed role in humans as the connection between the material and the spiritual world. The pineal organ was seen as a valve-like structure that regulated the flow of animal spirits through the ventricular system, a hypothesis that took on more vigour during the Middle Ages and the Renaissance. The framework for this theory was ''the three cells of the brain'', in which the pineal gland was even called the ''appendix of thought''. The pineal gland could also be associated with the boom, during this period, of certain legends about the ''stone of folly''. But the most relevant psychopathological role of this organ arrived with Des...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...
1995-12-31
Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)
Energy Technology Data Exchange (ETDEWEB)
The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and ...
2006-01-17
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction ...
1991-11-01
The role of Computerized Tomography in osteoid-osteoma diagnosis
International Nuclear Information System (INIS)
Alcaptonuria is a rare autosomal recessive metabolic disease, due to the lack of homogentisic acid oxidase. The following accumulation of homogentisic acid brings about a black discoloration of both the urine alcaptonuria) and connective tissue (ochronosis). The ochronotic alterations into joint cartilages cause degenerative arthropathy and osteopenia. The radiological features of three unrelated cases of alcaptonuria are reported. Radiographic abnormalities of ochconotic arthropathy are found in both the spine and the extraspinal joints. In the spine, the progressive calcification and ''vacuum'' phenomenon of disc spaces are the most characteristic findings. Disc space narrowing is associated with calcification and marginal sclerosis of vertebral bodies and is accentuated by osteopenia. Osteophytes are usually absent or of small size; neverthless progressive formation of marginal intervertebral bridges and obliteration of disc spaces at multiple levels ...
1988-01-01
Stochastic risk estimate for barium radiological examinations in Malaga (Spain)
International Nuclear Information System (INIS)
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective dose, annual effective dose 'per capita' and detriment, which are useful for assessing the population risk of cancer or hereditary ...
2000-01-01
Radon concentration measurements in the Amasra coal mine, Turkey
Energy Technology Data Exchange (ETDEWEB)
In this study, the results of atmospheric radon measurements that were performed for the Amasra underground coal mine in Zonguldak bituminous coal basin (Turkey) are presented. The radon measurements were performed for 40 days between November 2004 and December 2004 using passive nuclear etched track detectors. The radon concentrations vary from a minimum value 49 Bq m{sup -3} in a site located at +40 m to a maximum value 223 Bq m{sup -3} in a site located at -100 m. Mean concentration is 117 (Bq m{sup -3}). This value is well below the action level of 500-1500 Bq m{sup -3} recommended by the International Commission on Radiological Protection (ICRP) (1993). The mean effective dose value for workers of this mine of 3.4 {mu} Sv per day was obtained. This result shows that protection against radiological hazards would not be necessary for workers of this mine.
2006-04-15
Radiometric analysis of raw materials and end products in the Turkish ceramics industry
International Nuclear Information System (INIS)
This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. ...
2011-05-01
International Nuclear Information System (INIS)
At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in lead shielding inside spent fuel storage ...
2006-11-13
Radiological and Environmental Research Division: ecology. Annual report, January-December 1982
Energy Technology Data Exchange (ETDEWEB)
This is the annual report of the Radiological and Environmental Division of the Argonne National Laboratory for 1982. Studies of the effects of ozone on crop growth and yield have been carried out by the Terrestrial Ecology Group for winter wheat and for sorghum. The Microcosms for Acid Rain Studies (MARS) facility was completed in the early summer. Controlled investigations of plant and soil responses in acid rain were initiated with crop plants grown in two different midwestern soil types. The Transuranics Group has found that the solubility and adsorptive behavior of plutonium previously observed at fallout concentrations in natural waters (approx. 10/sup -16/ to 10/sup -18/ M) is applicable at plutonium concentrations as high as 10/sup -8/ M. The Lake Michigan eutrophication model has been adapted to operation in a Monte Carlo mode. Simulations based on yearly phosphorus loadings and winter conditions were selected at random from prescribed probability ...
1983-09-01
International Nuclear Information System (INIS)
With the exception of some minerals, the specific activity of natural radioactive material is below 370 Bq/g, their handling thus not being subject to authorization or the duty of reporting according to section 4 para. 2 of the Radiological Protection Ordinance. Moreover, there is required no handling license for prospecting, mining and processing of radioactive minerals; they are subject to the procedures for the plans of operation of the mining laws of the Federal States. License-free handling of natural radioactive material may result in the production of radioactive waste, the disposal of which must be authorized according to sect. 47 of the Radiological Protection Ordinance if the specific activity exceeds the free amounts of column 4 in Table IV of Appendix IV by a factor of 10"-"4/g. This inconsistency is discussed by means of the following examples: (1) fly ash and slag from coal power plants, (2) flue dust from sintering plants, (3) ...
1980-05-01
International Nuclear Information System (INIS)
This paper presents an overview of issues related to surface water contamination arising from uranium mining activities in the Alligator Rivers Region (ARR) of northern Australia, and a program of research and monitoring that must assess the potential and actual effects on ecosystem and human health. The program of assessing effects on aquatic ecosystems involves a four-tiered approach including the derivation of local water quality guideline trigger values, direct toxicity assessment of mine waters prior to their release, creekside or in situ monitoring for early warning of adverse effects during mine water release, and longer-term monitoring of macroinvertebrate and fish communities. Bioaccumulation in aquatic biota is also assessed, and is an issue of importance not only to ecosystem health, but also to the health of local Aboriginal people. The aquatic animals they consume represent potential sources of radiological dose, and as a result, a major component of ...
2002-12-27
Maintenance implementation plan for the B Plant/WESF. Revision 4
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the B Plant/WESF (Waste Encapsulation Storage Facility) complex. The objective of this plan is to provide baseline information for establishing and identifying WHC conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at B Plant/WESF. The B Plant WESF facility complex consists of three main facilities and several support structures located in the 200 East Area of the Hanford site. B Plant is a transition facility that is required to ensure safe storage and management of WESF (operating facility) cesium and strontium capsules. B Plant/WESF also contains substantial radiological inventory from previous campaigns. There are no production activities at B Plant, but several of its operating systems ...
1996-01-01
Experience in using Fuji computed radiography (FCR), 1
Energy Technology Data Exchange (ETDEWEB)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation doses of the chest ...
1984-12-01
Experience in using Fuji computed radiography (FCR), 1
International Nuclear Information System (INIS)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation doses of the chest ...
1984-01-01
International Nuclear Information System (INIS)
Decommissioning of radiological and nuclear installations is for this century the new challenge. One of the performance criteria is the reduction of total quantities of radioactive materials (liquid or solid) arising from dismantling and decontamination of radiological and nuclear installations. In this work we present a new application of the water soluble polymers used as: - flocculation agents in treatment and conditioning process within the management of radioactive liquid materials; - strippable coatings on solid materials based on the water soluble polymers. The parameters of water soluble polymers made in our Institute by radiation processing have been analysed, namely the molecular average weight, composition, and efficiency of utilization of these polymeric materials as well as the content of ash, additives, decontamination factor, consumption per surfaces/liter, corrosion aspects, compatibility with various surfaces (of metal, ...
2003-10-20
Energy Technology Data Exchange (ETDEWEB)
In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and ...
2002-12-01
Defense Threat Reduction Agency Radiochemical Needs
International Nuclear Information System (INIS)
The United States Government (USG) first developed nuclear forensics-related capabilities to analyze radiological and nuclear materials, including underground nuclear test debris and interdicted materials. Nuclear forensics is not a new mission for Department of Defense (DoD). The department's existing nuclear forensics capability is the result of programs that span six (6) decades and includes activities to assess foreign nuclear weapons testing activities, monitor and verify nuclear arms control treaties, and to support intelligence and law enforcement activities. Today, nuclear forensics must support not only weapons programs and nuclear smuggling incidents, but also the scientific analysis and subsequent attribution of terrorists' use of radiological or nuclear materials/devices. Nuclear forensics can help divulge the source of origin of nuclear materials, the type of design for an interdicted or detonated device, as well as the pathway of ...
2009-08-19
Energy Technology Data Exchange (ETDEWEB)
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow ...
1996-12-31
Computed tomography of the chest in the postoperative recurrences of bronchogenic carcinoma
International Nuclear Information System (INIS)
The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always mandatory, after subtotal resection the diagnostic accuracy of conventional ...
1990-01-01
International Nuclear Information System (INIS)
In 620 patients quantitative bone scintigraphy with "9"9"mTc pyrophosphate of the sacroiliac joints and of the spine was performed: 365 patients with confirmed ankylosing spondylitis, 125 patients with clinical radiological suspicion for ankylosing spondylitis (probable Bechterev) and control group of 130 healthy individuals. By comparison of the activity in zones of interest of the sacroiliac joints, the spine and sacrum, the following indices were determined: sacroiliac (separately for the left and right sacroiliac joints), index D_1_0/sacrum, index L_4/sacrum and index C_7/sacrum. The scintigraphic finding was compared to the X-ray one and to the radiological stage of the disease. A long-term follow-up of the patients was carried out during 1-6 years with scintigraphic, X-ray and clinical investigations. Emphasis was laid upon the posibilities for quantitative scintigraphy for early diagnostics of ankylosing spondylitis. The combination of ...
An aerial radiological survey of the Portsmouth Gaseous Diffusion Plant and surrounding area
International Nuclear Information System (INIS)
An aerial radiological survey was conducted from August 10-16, 1993, over a 78-square-kilometer (30-square-mile) area of the Portsmouth Gaseous Diffusion Plant and surrounding area located near Portsmouth, Ohio. The survey was performed at a nominal altitude of 46 meters (150 feet) with a line spacing of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on a set of United States Geological Survey topographic maps of the area and an aerial photograph of the plant. The terrestrial gamma exposure rates varied from about 7 to 14 microroentgens per hour at 1 meter above the ground. Protactinium-234m was observed at six sites within the boundaries of the plant. At a seventh site, only uranium-235 was observed. No other man-made, gamma ray-emitting radioactive material was present in a detectable quantity, either on or off the plant property. Soil sample and pressurized ion ...
2005-05-01
An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington
International Nuclear Information System (INIS)
An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...
1990-09-16
International Nuclear Information System (INIS)
An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure rate obtained from soil samples and ionization chamber ...
Energy Technology Data Exchange (ETDEWEB)
The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over arbitrary 12 time interval has been designed and manufactured. ...
1995-07-01
International Nuclear Information System (INIS)
A computational procedure is proposed to perform uncertainty analysis for the calculation of the isotopic inventory and radiological quantities obtained as a linear function of it, due to uncertainties in the activation cross sections. The method is applied to determine the uncertainty of the calculated shallow burial index (SBI) from activated type 304 stainless steel (SS) in the most neutron-exposed zone of the HYLIFE-II vessel structure. Results are obtained by means of an element-by-element study. Some other types of steel are also investigated for comparison purposes. The SS304 is confirmed to be the most promising steel option. 16 refs., 2 tabs.
1996-06-16
Three-dimensional cranio-facial computed tomography
International Nuclear Information System (INIS)
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
1986-01-01
Scintigraphic detection of a radiologically equivocal fracture
Energy Technology Data Exchange (ETDEWEB)
This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period.
1988-04-01
Scintigraphic detection of a radiologically equivocal fracture
International Nuclear Information System (INIS)
This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period. (orig.).
Radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.
1988-01-01
Radiological criteria, potential and limitations of ADTT at closing nuclear fuel cycle
International Nuclear Information System (INIS)
Closure of nuclear fuel cycle is considered as a way to reduce the hazards of nuclear power industry waste. The potential and prospects of different technologies and installations including ADTT in solving this problem are discussed. A new relative criterion is proposed to assess the dangers of the waste. Equilibrium mode approximation is used in the estimates. It is shown that irretrievable losses of actinides do not depend on relative intensity of burning. Neutron economy of accelerator-driven blankets is considered and an expression is derived for transmutation value of 'external' neutrons. 8 refs., 2 tabs.
1996-06-01
Radiation safety in industrial applications
International Nuclear Information System (INIS)
Oil and gas industry is the largest user of radioactive materials in Nigeria. They make use of radiation generators, sealed and unsealed radioactive sources.Some of these are potentially dangerous to human health and environment if not properly controlled. here is also the need to maintain control over occupational exposures to radiation, as well as to protect the public and the environment through proper management of wastes that may be radiologically hazardous. To minimize these, effective regulatory infrastructure is being put in place.For a smooth take-off of the nuclear power program, the National Nuclear Regulatory Authority and other stake holders in the nuclear industry need to start to put together licensing procedure for these.
2008-03-17
British Library Electronic Table of Contents (United Kingdom)
Abstract Prostate leiomyosarcoma is an extremely rare and highly aggressive neoplasm that accounts for less than 0.1% of primary prostate malignancies. Herein, we present a patient with primary leiomyosarcoma of the prostate with lung metastasis diagnosed primarily on fine-needle aspiration cytology. Characteristic cytological features such as small fascicles of spindle cells with blunt-ended nuclei, positivity for desmin and smooth muscle actin along with the radiological features are helpful in the correct diagnosis. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In the present paper a review of the Dutch RAS programme is presented. The objectives and achievements of the programme are described. Special attention is given to a recent assessment of the international status of P and T that has been made for the Dutch authorities. The major conclusion of this assessment is that P and T is an important instrument in the management of nuclear waste to achieve the technical limits (ALARA) with respect to radiotoxicity of the waste inventory as well as radiological effects of the disposal. The technology for P and T is, however, only partially available at present and recommendations for the directions of the RAS programme are given. (orig.).
1996-08-01
International Nuclear Information System (INIS)
Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity
2010-02-01
New concepts in risk assessment for patients with radiological treatment
International Nuclear Information System (INIS)
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
1986-01-01
International Nuclear Information System (INIS)
The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.
2003-05-01
International trends in radiation protection
International Nuclear Information System (INIS)
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
High Exposure Facility Technical Description
Energy Technology Data Exchange (ETDEWEB)
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
2008-02-12
Energy Technology Data Exchange (ETDEWEB)
The paper investigates the yield and the role of the computerized tomography in diagnosing abdominal gunshot wounds, with their rich and varied radiological signs and associated injuries, and subsequently used in the diagnosis. [Italian] Scopo del lavoro e' riportare l'esperienza personale nell'uso della tomografia computerizzata per riconoscere le lesioni da arma da fuoco dell'addome e nelle fasi successive dell'approfondimento diagnostico.
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
The legal basis to be provided is a licence for decommissioning work, issued for a particular reactor, including activities for recycling of disassembled, radioactive components and materials, subject to radioactivity measurements and exemption from radiological control of materials not exceeding the legally defined maximum level of contamination. (HP) [Deutsch] Es genuegt eine Stillegungsgenehmigung zu einem konkreten Abbauauftrag mit Verwertung radioaktiver Reststoffe nach Freigabe durch Radioaktivitaetsgrenzwertsfestsetzung. (HP)
1995-12-31
Documentation of a model action plan to deter illicit nuclear trafficking
International Nuclear Information System (INIS)
Theft, illegal possession, smuggling, or attempted unauthorized sale of nuclear and radiological materials remains a worldwide problem. The Nuclear Smuggling International Technical Working Group (ITWG) has adopted a model action plan to guide investigation of these cases through a systematic approach to nuclear forensics. The model action plan was recently documented and provides recommendations concerning incident response, collection of evidence in conformance with required legal standards, laboratory sampling and distribution of samples, radioactive materials analysis, including categorization and characterization of samples, forensics analysis of conventional evidence, and case development including interpretation of forensic signatures. (author)
2008-05-01
Development of the SRS environmental counting laboratory gamma spectroscopy system
International Nuclear Information System (INIS)
The Savannah River Site (SRS), one of several U.S. Department of Energy (DOE) facilities, produces nuclear materials for national defense and for other government and civilian uses. SRS ceased production of defense materials in 1988, and the site's main activities now involve waste management and environmental restoration. These programs have generated extensive effluent monitoring and environmental surveillance programs for the Environmental Monitoring Section (EMS), which performs #approx#105,000 radiological analyses on 30,000 samples a year. Gamma spectroscopy is performed on an estimated 10,000 samples annually. This report describes a program to develop and improve the EMS system.
1996-06-16
Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications
International Nuclear Information System (INIS)
The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth.
1999-11-01
International Nuclear Information System (INIS)
Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)
2008-07-01
International Nuclear Information System (INIS)
Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)
2005-01-01
A marine compartment model for collective dose assessment of liquid radioactive effluents
International Nuclear Information System (INIS)
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
1982-01-01
The new 2.2 l ECOTEC aluminium engine by Opel; Der neue 2,2-l-ECOTEC-Aluminium-Motor von Opel
Energy Technology Data Exchange (ETDEWEB)
The ECOTEC combustion system and the architecture of the new Opel 2.2 l aluminum engine have been configured to achieve low noise and exhaust emissions. This power unit, employed in Germany for the first time in the Astra Coupe, already complies with the Euro IV emissions standard. It features minimum maintenance requirements and a long operating life. The DOHC spark-ignition engine with four valves per cylinder has two chain-driven camshafts, valve gear with roller cam followers and hydraulic lash adjusters. Two chain driven balancer shafts have been integrated into the engine block. The cylinder head and block, lower crankcase, oil pan, and cylinder head cover are all made of aluminum. A modular concept makes it possible to adapt the engine effectively to different vehicle concepts and markets. (orig.) [German] Das ECOTEC-Verbrennungssystem und die Motorarchitektur des neuen 2,2-l-Aluminium-Triebwerks von Opel sind auf niedrige Geraeusch- und ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is concluded that the integrity of the containment is not challenged during a loss of coolant accident at ...
2001-07-01
International Nuclear Information System (INIS)
The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK activity. Serum MB CPK activity increased after cardiac surgery in 6 patients undergoing ...
Heat pipe cooled piston - feasibility study
Energy Technology Data Exchange (ETDEWEB)
This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat pipe, in which the return of the condensate to the evaporator section is achieved by the movement of the heat pipe. The ...
2004-07-01
HT technology -- All-metal sealing answers safety and environmental concerns
Energy Technology Data Exchange (ETDEWEB)
This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
A gas-diesel dual fuel engine apparatus is described having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including a gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine through the control of fuel supplied to the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode. The improvement of the governing and controlling device consists of: (a) at least one electronic governor means adapted to compare a speed signal representing the actual operating speed of the diesel engine with a set speed signal representing the set speed thereof; (b) a pair of electric actuator means having respective power amplifier circuits and mechanically connected to the diesel fuel injection pump and the gaseous fuel regulating valve, respectively, for the actuation thereof; (c) mode ...
1986-03-18
Electron-beam welding of valve bodies; Elektronenstrahlschweissen von Armaturengehaeusen
Energy Technology Data Exchange (ETDEWEB)
In early March, 2000 a modern electron-beam welding facility for both series and one-off production of valves bodies (500 kg, up to 50 mm wall thickness) was commissioned at Josch Strahlschweisstechnik. Welding is performed under a fine vacuum. This permits not only the welding of components subject to acceptance inspection (HP0 approval), but also of special materials such as titanium, molybdenum, tungsten, Hastelloy and copper, and also their pairings. Products are developed and readied for production using modern 3D CAD software. A modern nine-axis control system makes it possible to produce sockets in pipe-on-pipe joints. (orig.) [German] Anfang Maerz 2000 wurde eine moderne Elektronenstrahlschweissanlage fuer die Herstellung von Armaturengehaeusen in Grossserien oder auch fuer Einzelfertigung (500 kg, bis 50 mm Wanddicke) bei der Josch Strahlschweisstechnik in Betrieb genommen. Die Schweissungen erfolgen im Feinvakuum. Somit koennen neben dem Schweissen ...
2000-03-01
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified pre-accident human ...
2003-04-20
Scientific Electronic Library Online (English)
Abstract in english AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, pati (more) ents' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be ...
2010-06-15
International Nuclear Information System (INIS)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last ...
2010-06-01
International Nuclear Information System (INIS)
After five years of implantation of a program for classification and signalling of restricted areas in the IPEN-CNEN-SP, we noticed that the applied measures of radio protection contributed for the improvement of the system of occupational radiological protection, promoting an improvement in the security of the workers, towards the planning in the execution of the activities involving the use of sources of ionizing radiation. Later, during the implantation of this program, the service of occupational radiological protection, there was great difficulty to conciliate its necessities in terms of security signalling, face the absence of existing standardisation in the country for the minimum disposals on the subject in question. Nowadays there are different interpretations of the specific criteria and many effective normative documents that exist in the country. This work presents as proposal the elaboration of a technical guide whose objective is ...
A.C.R.O. activity report 1999; A.C.R.O. rapport d'activite scientifique 1999
Energy Technology Data Exchange (ETDEWEB)
The work of this association is cut according to 6 axes. Three publications: radiological quality of marine and continental waters of the Normandy coast (synthesis 1997 and 1998); preliminary study of the iodine 129 distribution in the environment of the reprocessing plant of La Hague with terrestrial moss (Homalotecium sericeum); radiological surveillance of the aquatic environment of the nuclear facilities on the area of La Hague (1997 and 1998). The second axis concerns the radiation protection with a campaign of radon measures in a school of the Vire rural district (june 1999). The third part is devoted to the radioecology with the surveillance of radioactivity in the aquatic continental environment of nuclear facilities and the radioecological surveillance (1999) of the building site of Cogema la Hague in the area of tidal range of the Moulinets cove. The fourth part concerns the radioactive waste and environment, with the study of the ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
This report documents the concluding efforts at the Engineering Sciences Laboratory of TRW on two specific areas of current research activity within the more general context of proposed lean-burn operation of Otto-cycle-type automotive engines. These areas are: (1) achievement of knock-free performance, both under available fuels and current compression ratios and also under higher-octane fuels (e.g., alcohols) and higher-compression-ratio design (for greater thermal efficiency); and (2) identification of counterstrategies for two-wall (crevice-type) quenching of flame propagation, a phenomenon now widely acknowledged to be the major source of unburned-hydrocarbon emissions exhausted from homogeneous-charge cyclinders. There are certainly other highly active areas of research in Otto-cycle engines, such as turbocharging, ignition devices, and valve design, but the two above-cited topics were the topics of this project.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in ...
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
With an objective to use reproducible vegetable oil as a substitute fuel, studies were performed to use emulsified rapeseed oil at an optimal mixing ratio with water in a direct injection diesel engine. The experiment used a water cooled, lateral installation, single-cylinder, direct injection, four-cycle diesel engine, and the tested fuel used an emulsified rapeseed oil fuel with rapeseed oil added with water at a rate of 20% by weight. As a result of the experiment using the emulsified rapeseed oil, it was found that reducing the injection opening diameter smaller than the standard opening diameter improves the engine performance and simultaneously reduces concentrations of HC, CO and exhaust smoke. The optimal opening diameter was about 0.22 mm. Increasing the valve opening pressure reduced the NOx concentration, but increased the HC concentration. Using the emulsified rapeseed oil fuel accumulated more carbon below the head, but much smaller amount on the ...
1994-09-30
Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to ...
2008-11-15
The year 2000 embedded systems problem to maintain the safety of nuclear installations
International Nuclear Information System (INIS)
The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a valve, may control the flow of cooling system to reactor core. Embedded systems in our organization are also be found in Batan ...
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
Today, as a result of increase in oil prices, limited fossil fuel resources, environmental consideration and global warming, the methyl ester fuels have been focused on alternative fuels. Methyl ester fuels can be used more efficiently in low heat rejection engines (LHR), in which the temperature of combustion chamber is increased by creating a thermal barrier. In this study, the piston, cylinder head, exhaust and inlet valves of a diesel engine were coated with the ceramic material Al{sub 2}O{sub 3}-TiO{sub 2} by the plasma spray method. Thus, a thermal barrier was provided for the parts of the combustion chamber with these coatings. The effects of corn oil methyl ester that produced by the transesterification method, and No. D2 fuels' performance and exhaust emissions' rate were studied by using equal in every respect coated and uncoated engines. Tests were performed on the uncoated engine, and then repeated on the coated engine and the results ...
2010-10-15
The French design code: RCC-M status and on-going developments
International Nuclear Information System (INIS)
Since 1978, an important effort has been on-going between Framatome and Electricite de France (EDF) to develop and update technical rules for the design and construction of nuclear power plants. Two design codes are developed, one for PWRs: RCC-M and one for FBRs: RCC-MR. After some comments on the organization of RCCM Commission, the paper presents: (1) the major differences with the ASME Section III Code for fatigue, plastic shakedown and rupture analysis; (2) the review of some important facts in terms of availability or maintenance costs (in-service inspection, replacements, repairs, etc.) of operating plants like underclad cracking, stratification, CRDM nozzles, cast elbows, steam generator tubes, etc.; (3) how can one take into consideration this operating feedback in RCC-M Code; and (4) few examples of major on-going developments for fracture analysis on different components and fatigue analysis of valves. In conclusion, the standardization of the plants is ...
1996-07-21
Energy Technology Data Exchange (ETDEWEB)
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, which is very low compared to the consumption of electric heating (0.286 GJ per sq.m) or oil heating (0.419 GJ per sq.m). 4 figs., 1 tab.
1996-12-01
Simulation for transient stability study of the Taiwan power system - a nuclear majority system
Energy Technology Data Exchange (ETDEWEB)
A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional four functions: load-limit operation simulated by a low-value ...
1984-01-01
Simulation for transient stability study of the Taiwan power system - a nuclear majority system
International Nuclear Information System (INIS)
A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional four functions: load-limit operation simulated by a low-value ...
Sealing of nuclear plant electrical equipment: Final report
International Nuclear Information System (INIS)
The nuclear power industry has many applications where electrical equipment is required to operate in environments which contain high relative humidity, steam and water or chemical sprays. Equipment is susceptible to these environments by moisture entering through inherent design provisions such as O-rings and through the electrical interface. The objective of this research is to review electrical interface sealing techniques and to recommend methods for providing effective electrical interface sealing. The most common methods of sealing are the use of electrical fittings containing sealants, add-on assemblies and hardware changeout. The experience gained in several years of testing electrical interface seals on such devices as limit switches, solenoid valves and transmitters is presented to provide information on seal effectiveness and preferred application. The effectiveness of various sealing methods is discussed, each of which is dependent upon the device being ...
Energy Technology Data Exchange (ETDEWEB)
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of radiation dose equivalent based ...
1990-03-01
Reliability analysis for stiff versus flexible piping
Energy Technology Data Exchange (ETDEWEB)
The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. We then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. We concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of supports and snubbers without violating ASME code requirements. Furthermore, the more flexible piping redesigns are capable of exhibiting reliability levels equal to or higher than the original stiffer design. An ...
1985-11-01
Energy Technology Data Exchange (ETDEWEB)
The control of nitrogen oxides (NO{sub x}) emissions will become a major challenge in the forthcoming years, in the domain of automotive industry or industrial burners. Pulsed combustion offers an imaginative solution which does not affect the combustion efficiency. In this paper, the efficiency of this method is demonstrated using the burner of a 20 kW domestic boiler. The actuator is simply installed on the air intake. Two types of actuators have been tested successfully: a loudspeaker and a rotative valve. Both can produce 100 to 1000 Hz frequencies and can lead to a reduction of 20% of NO{sub x} emissions. The feasibility of the concept is also demonstrated on a 840 kW liquid fuel-oil burner. The mechanisms involved during an excitation are explained using the CH{sup *} radical imaging. Results show an important reorganization of the flow and of the flame structure. During each excitation cycle, an annular swirl occurs at the leading edge of the flame catching ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation grade is wanted. Valves for exhaust control require high-temperature rigidity, ...
1992-06-18
Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation
International Nuclear Information System (INIS)
Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).
2005-07-15
Energy Technology Data Exchange (ETDEWEB)
A preliminary guideline for the design and evaluation of LMR high temperature structure is presented based upon ASME B and PV Code, Section III, Subsection NH. The main contents of this guideline are the materials, general design, vessel, piping, core support structure, pumps, valves, fabrication, examination, and testing for the class 1 components. The ratcheting evaluation, enhanced creep assessment, welds design and evaluation, inelastic analysis approach, piping design alternatives, and bellows design method are described in appendices. A user of this guideline should follow the essential procedures and may refer to other pertinent codes, standards, laws, regulations, or other pertinent documents when this guideline does not lead to proper design of the structure. While this guideline adopts major procedures of Subsection NH, it refers to the RCC-MR and/or DDS in some amount for the items where these codes have excellency to improve this guideline.
2007-02-15
Energy Technology Data Exchange (ETDEWEB)
The fuel-injection system of the Niigata 6L 16X-AG dual-fuel engine is structured to steadily supply injected fuel during diesel-engine operation, and to distribute oil at a low rate to all the cylinders during gas-engine operation. The dual-fuel engine is started by the diesel engine operation and is changed over to gas-engine operation when the load increases. This change over is done automatically with a link mechanism. Regarding the gas-supply system, the changing pressure of supply gas is controlled by a pressure control valve which is stable and most adequate for the engine. The dual-fuel engine has the following features: (1) a high compression ratio is adopted, which reduces fuel consumption and thermal efficiently; (2) if the supply of gas decreases or stops, while continuing loaded operations, it can immediately shift to diesel engine operation automatically and continue the operation; (3) ignition is done by the injection of pilot oil, thus eliminating ...
1980-01-01
Metallic implants and exposure to radiofrequency radiation
International Nuclear Information System (INIS)
There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in ...
Energy Technology Data Exchange (ETDEWEB)
Swirling flow in a direct injection diesel engine was measured by a laser doppler velocimeter. Piston cavity diameter and top clearance volume were changed as factors affecting swirling flow to study the distribution of swirling flow speed. When using the same intake port and changing the opening ratio of piston cavity, the distribution of swirling flow speed was different by the cavity during intake process but these agree just after opening intake valve and then become again different by cavity. When increasing top clearance and decreasing compression ratio, the axial symmetry of flow during commpression process increases. When changing piston cavity, and also when changing intake port, the mean swirling ratio in inside and outside areas of combustion chamber has common tendency to increase and decrease respectively. The mean swirling flow in the combustion chamber may be capable to be predicted by devising a model which can describe this tendency. 3 refs., 9 ...
1989-05-31
Energy Technology Data Exchange (ETDEWEB)
Swirling speed in a direct injection diesel engine was measured by a laser doppler velocimeter. Intake port geometry and engine speed were changed as factors affecting the swirling flow to study the distribution of swirling flow speed. The distribution of swirling flow speed changes complicatedly owing to axial nonsymmetry during intake process but becomes simple shape of axial symmetry during compression process after closing intake valve. But if this is assumed as the rigid swirl shape, the difference due to each intake port cannot be expressed but also large error may be possible to appear close to the cylinder wall. The distribution of swirling flow speed during compression process changes similarly, nearly proportinal to engine speed. But the similarity is higher at the middle period in compression process than at the end period in compression period. Axial distribution of local swirling ratio during compression process is nearly uniform. 8 refs., 10 figs., 1 ...
1989-05-31
Management and optimization of the CPCU network working
Energy Technology Data Exchange (ETDEWEB)
The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for the establishing management data in real time. For the water, the system forecasts the ...
1991-10-01
Loss of flow incident - Simulation and measurements in the MPR
International Nuclear Information System (INIS)
As part of the Probabilistic Safety Analysis of the Multi Purpose Reactor, MPR, the list of Postulated Initiating Events was analyzed and one of these PIEs corresponds to the Loss of Coolant Flow. It is well known that during the operation life of a research reactor a LOFA could eventually occur and, once this event takes place, in time detection and automatic actions, thanks to the engineering safety features of the system, will mitigate the incident evolution. The postulated event corresponds to a loss of flow due to a total loss of power supply. The goal of the present work is to provide a general description and the engineering safety features of the MPR, as well as describe the sequence of scenarios during a LOFA. Temporal evolution of main parameters is presented, also. During Stage A of the Commissioning Program measurements of the core cooling system pump coast-down were performed in order to validate previous simulation results, as well as, flap valves ...
1999-10-26
Ion exchange at TNX using the SKID unit
Energy Technology Data Exchange (ETDEWEB)
An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination factor (DF) will be measured for a non-radioactive, simulated, ...
1993-10-21
Innovative coke oven gas cleaning system for retrofit applications
Energy Technology Data Exchange (ETDEWEB)
All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by BSC and DSO and will not be placed until ...
1990-09-10
Higher order time-frequency analysis as a tool for health monitoring
Energy Technology Data Exchange (ETDEWEB)
In machine condition monitoring many fault-related vibration signals are highly non-stationary. Time-frequency representations comprise the natural signal-processing tool traditionally used for representing such non-stationary signals. The methods used in this analysis are based on the second order statistics of a signal. This paper discusses the use of higher order time frequency methods in the context of a condition monitoring application. The paper outlines the two classes of higher order representations: the L-Wigner distribution and the sliced Wigner higher order distribution. The use of higher order distributions introduces the possibility of non-oscillating cross-terms, a problem not encountered in conventional bilinear time-frequency methods. Techniques for reducing these cross-terms are presented. The paper compares the performance of bilinear and higher order time-frequency methods using synthetic data and vibration signals measured on the engine block of the passenger car ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
Causes of variation of hydrocarbon (HC) concentration in cylinder to cylinder at idling condition in a direct injection diesel engine were studied. The ratio of l/d=6 gives larger HC variation in cylinder to cylinder than the l/d=2, where l means the nozzle hole length and d means the nozzle hole diameter. This is because the condition of l/d=6 can result in the large spray penetration and increase the fuel on the combustion chamber. The spray structure changes between nozzles and also changes between nozzle holes. This is not caused by the shape of nozzle hole but is affected by the pressure change near the inlet of nozzle hole when the needle valve is lifted. The change of spray structure can change the injection volume between nozzle holes. The injection volume is less for a nozzle hole where the curved angle becomes sharp to the nozzle central angle, and is more at the opposite side. When the injection volume of the nozzle hole near the chamber wall increases, ...
1992-07-01
The goal of GRI's Gas Appliance Technology Center is to encourage the introduction of highly efficient, cost-effective, convenient gas appliances for residential and commercial gas users. The report covers activity at Battelle from February 1989 to April 1990 in broad support tasks, residential and commercial appliances, and residential space conditioning. Broad support tasks included the G/A/S Newsletter; the GATC InfoBase; and technology transfer, workshops, and GATC coordination. Residential appliance tasks included burner technology research, gas appliance venting, gas lighting, and plastics durability. Commercial appliance tasks included development of a commercial cooktop fuel/air mixing valve. Residential space conditioning tasks included a corrosion test method for gas appliances and vents, generic technology for condensing heat exchangers, and technology for self-powered appliances. These tasks are described briefly, with references to reports and ...
1990-12-01
Fast diagnosis and treatment of crack-like defect injuriousness in nuclear power plant equipment
Energy Technology Data Exchange (ETDEWEB)
Increasingly stringent safety requirements governing the nuclear industry have made it essential to gain in-depth knowledge of the injuriousness of cracking phenomena in auxiliary and secondary nuclear power plant systems, and to devise methods of rapidly evaluating potentially injurious flaws. The Defect Injuriousness Diagnosis and Treatment Package (DIDTP) discussed in this paper was developed by Framatome, a French-based PWR builder, with this goal in mind. A general description is given of the DIDTP, which is made up of tables and nomographs illustrating the injuriousness of flaws liable to be encountered in the most severely loaded regions of plant systems. The basic principles underlying the DIDTP, together with computational methods and application procedure, are detailed. Two practical examples illustrating the use of the diagnostic system are presented, one applied to the main steam line, the other to gate valve wedges. The types of results obtained and ...
1985-01-01
British Library Electronic Table of Contents (United Kingdom)
Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated in the natural convection dominated region for a wide range of Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.02win0.025m/s) using a flow rate control valve so that Reynolds number was always about ...
2009-01-01
Evaluation of spark ignition of a gas cooktop flame
One of the energy-saving devices used on gas cooking appliances to eliminate the standing pilot is a spark ignition system. For safety, an ignition system must start promptly and be active whenever flowing gas is not ignited. To minimize noise and nuisance shock hazard, ignition must occur quickly and the sparking must be stopped as soon as ignition occurs and remain off as long as the flame is present. To accomplish both of these requirements, ignition systems have been devised which use the electrical current rectification property of a flame to sense it. These systems spark whenever the gas valve is on and a flame is not present. The factors affecting the performance of a spark ignition system are numerous, complex, and transient. All of these properties make quantification of performance difficult. A system is described which can evaluate the overall performance of ignition systems over significant periods of time and varieties of operating conditions and ...
1996-01-01
International Nuclear Information System (INIS)
In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, loss of the GDCS pool water is prevented and ...
1990-10-29
Electronic fuel injection techniques for hydrogen powered i. c. engines
Energy Technology Data Exchange (ETDEWEB)
Numerous studies have demonstrated the advantages of hydrogen as a fuel for Otto Cycle engines due to high thermal efficiency and low exhaust pollutant levels. Characteristic of hydrogen engine operation using premixed intake charge formation is a problem of pre-ignition resulting in an intake manifold backfire. Additional problems include high NO production when using certain equivalence ratios and power output degradation due to low fuel energy/volume density. Techniques for direct and port fuel injection are discussed as means for overcoming these problems. Emphasis is placed on the need for total engine control, integrating control of fuel injection, ignition timing, intake air throttling, and vehicle subsystems within a central electronic unit. An electronically actuated fuel injection valve and a prototype electronic control system are developed. These are applied in port and direct injection system geometries, and evaluated in engine testing. System ...
1980-01-01
Digital luminescent radiography: A substitute for conventional chest radiography?
International Nuclear Information System (INIS)
The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a ...
Device for controlling water supply to nuclear reactor
International Nuclear Information System (INIS)
Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator generating signals for indicating whether one or two water supply pumps are operated. A low value preferential circuit passes the lower of the values generated from the ...
Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis
Energy Technology Data Exchange (ETDEWEB)
The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application includes heat transfer model of nuclear fuel assembly, decay heat ...
2001-03-01
Development of a 1200 KW/CYL low pressure dual fuel engine for LNG carriers
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant fouling of the combustion chamber is still ...
1998-12-31
Characterization and nanopatterning of Ni{sub 2}MnIn Heusler films
Energy Technology Data Exchange (ETDEWEB)
The Heusler alloy Ni{sub 2}MnIn is a promising material as spin injector because of its predicted half-metallicity at the interface to InAs. We grow thin films of this Heusler alloy by thermal coevaporation of Nickel and the alloy MnIn. The alloy is grown on Si{sub 3}N{sub 4} membranes and amorphous carbon films for transmission-electron microscopy (TEM) as well as on Si and InAs. The degree of the transport spin polarization of the films grown on Si(100), InAs(100) and in-situ cleaved (110) surfaces of InAs is determined by point-contact Andreev reflection spectroscopy (PCAR). The almost perfect lattice match between InAs and Ni{sub 2}MnIn supports highly oriented growth, as we have proven by electron diffraction under grazing incidence. Lateral spin valves with Heusler electrodes are lithographically defined. In view of the temperature-sensitivity of the optical and electron-beam resists, the samples are grown at substrate temperatures of 50 C and annealed up to ...
2008-07-01
Brazilian onshore pipelines rehabilitation program
Energy Technology Data Exchange (ETDEWEB)
Brazil currently has an oil and transport system with approximately 15,000 km of pipeline. However, energy needs are now increasing due to rapid population growth and expanding industrial activities in the country. This paper provided details of a pipeline rehabilitation program conducted across 424 km of pipeline in northeastern Brazil. The pipeline crossed 32 municipal districts. Over 37 replacements and upgrades were completed as part of the rehabilitation program. Surveys were completed to verify depth of pipeline cover, as well as to examined the condition of the external pipe coating, and the operational status of the cathodic protection (CP) system. Shutdown of the pipeline was completed during a 14 hour period, and included depressurization, cutting work, welding, and repressurization. Services included pigging to evaluate pipe-wall thickness; corrosion section replacement; an investigation of class locations during the operating life of the pipeline; the replacement of some ...
2004-07-01
An analysis of PZR and related system design features for KNGR
Energy Technology Data Exchange (ETDEWEB)
The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were higher and lower, respectively than those of UCN 3 and 4. Also, it ...
1995-12-01
Ambient air pollution and congenital heart disease: a register-based study.
Maternal exposure to ambient air pollution has increasingly been linked to adverse pregnancy outcomes. The evidence linking this exposure to congenital anomalies is still limited and controversial. This case-control study investigated the association between maternal exposure to ambient particulate matter with aerodynamic diameter less than 10 ?m (PM(10)), sulfur dioxide (SO(2)), nitrogen dioxide, nitric oxide (NO), ozone (O(3)), and carbon monoxide (CO) and the occurrence of congenital heart disease in the population of Northeast England (1993-2003). Each case and control was assigned weekly average (weeks 3-8 of pregnancy) of pollutant levels measured by the closest monitor to the mother's residential postcode. Using exposure as both continuous and categorical variables, logistic regression models were constructed to quantify the adjusted odds ratios of exposure to air pollutants and the occurrence of each outcome group. We found exposure to CO and NO to be associated with ...
2011-02-17
Advanced PWR technology development -Development of advanced PWR system analysis technology-
Energy Technology Data Exchange (ETDEWEB)
The primary scope of this study is to establish the analysis technology for the advanced reactor designed on the basis of the passive and inherent safety concepts. This study is extended to the application of these technology to the safety analysis of the passive reactor. The study was performed for the small and medium sized reactor and the large sized reactor by focusing on the development of the analysis technology for the passive components. Among the identified concepts the once-through steam generator, the natural circulation of the integral reactor, heat pipe for containment cooling, and hydraulic valve were selected as the high priority items to be developed and the related studies are being performed for these items. For the large sized passive reactor, the study plans to extend the applicability of the best estimate computer code RELAP5/MOD3 which is widely used for the safety analyses of the reactor system. The improvement and supplementation study of ...
1995-07-01
A modular and extensible data acquisition and control system for testing superconducting magnets
Energy Technology Data Exchange (ETDEWEB)
The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both extensibility and flexibility. As a result, the complexity of the hardware is ...
2001-07-20
The new 2.2l ECOTEC aluminium engine by OPEL; Der neue 2,2l ECOTEC Aluminium Motor von OPEL
Energy Technology Data Exchange (ETDEWEB)
The ECOTEC is a mass-efficient gasoline DOHC 4-valve per cylinder engine with balance shafts, chain driven camshafts and roller finger followers with hydraulic lash adjusters for valve actuation. It has lightweight aluminium components such as camcover, cylinder head, cylinder block, lower crankcase and structural oil pan. Other features include composite intake manifold and a coil-on-plug ignition cassette. The ECOTEC combustion system and engine architecture are optimized for low engine out and tail pipe emissions. It also includes several designed-in 'green' features for environmental benefits. The product design, development and validation process drew upon the best knowledge and practices available worldwide both inside and outside General Motor. The manufacturing systems were also designed by leveraging the best available knowledge around the world resulting in implementation of world class processes and error proofing ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
1995-01-01
International Nuclear Information System (INIS)
This paper overviews the curricula of nuclear medicine (NM) undergraduate training in 34 Central and Eastern European (CEE) and 37 European Union (EU) medical faculties. The data show enormous variation in the number of hours devoted to nuclear medicine, varying between 1-2 to 40 hours and highly differentiated concepts/ideas of nuclear medicine training in particular countries. In most EU countries this teaching is integrated with that of radiology or clinical modules, also with training in clinical physiology. In many CEE countries teaching and testing of NM are independent, although integration with other teaching modules is frequent. The paper discusses the differences in particular approaches to nuclear medicine teaching. (author)
Training And Education Needs In Radiological Protection - First Results Of The ENETRAP Survey
Energy Technology Data Exchange (ETDEWEB)
Recent studies have shown that there is a wide variety of approaches to education and training of the Qualified Expert across the European Union. National education and training programmes show often large differences in content, duration, level, the introduction of practical work, etc. As they stand, such differences are a barrier to the mutual recognition of the Qualified Expert status and, in part, are contributing to a perceived shortage in expertise in radiation protection and safety. The overall aim of ENETRAP is to determine mechanisms that in the longer term will facilitate better integration of education and training activities (with a view to mutual recognition across the European Union) and to ensure the ongoing provision of the necessary competence and expertise at the level of the Qualified Expert. The ENETRAP project is a 6FP coordination action. It started in April 2005 and runs over a period of 24 months. (authors)
2006-07-01
British Library Electronic Table of Contents (United Kingdom)
MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...
2011-01-01
The development of thyroid dose assessment software for nuclear or radiological emergency
International Nuclear Information System (INIS)
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
2006-12-01
Energy Technology Data Exchange (ETDEWEB)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-05-01
International Nuclear Information System (INIS)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-01-01
Studies on natural radioactivity of some egyptian building materials
International Nuclear Information System (INIS)
Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.
2004-02-24
Energy Technology Data Exchange (ETDEWEB)
To evaluate the current situation and implementation of embolization of uterine leiomyomas into the treatment concept in women with symptomatic uterine leiomyomas in Germany. A questionnaire addressing the clinical background of uterine myomas, recommended treatment concepts, preclinical evaluation, technical approach and complications was sent to 164 departments of gynecology and radiology in Germany. 33 radiological departments and 19 gynecological departments submitted a completed questionnaire. Only 7 departments of radiology reported to have own experience with embolization of uterine leiomyomas, while only 2 departments of gynecology considered embolization as an alternative treatment option in patients with symptomatic leiomyomas. 18/33 radiological departments offer this treatment option but get no patient referrals. Agreement was found concerning the indications for treatment, preclinical ...
2003-08-01
International Nuclear Information System (INIS)
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).
Severe paraquat poisoning: clinical and radiological findings in a survivor
International Nuclear Information System (INIS)
Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the therapeutic algorithm for severe paraquat ...
Severe paraquat poisoning: clinical and radiological findings in a survivor
Energy Technology Data Exchange (ETDEWEB)
Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the therapeutic algorithm for severe paraquat ...
2010-07-01
Science and Technology Review July/August 2010
Energy Technology Data Exchange (ETDEWEB)
This issue has the following articles: (1) Deterrence with a Minimum Nuclear Stockpile - Commentary by Bruce T. Goodwin; (2) Enhancing Confidence in the Nation's Nuclear Stockpile - Livermore experts are participating in a national effort aimed at predicting how nuclear weapon materials and systems will likely change over time; (3) Narrowing Uncertainties - For climate modeling and many other fields, understanding uncertainty, or margin of error, is critical; (4) Insight into a Deadly Disease - Laboratory experiments reveal the pathogenesis of tularemia in host cells, bringing scientists closer to developing a vaccine for this debilitating disease. (5) Return to Rongelap - On the Rongelap Atoll, Livermore scientists are working to minimize radiological exposure for natives now living on or wishing to return to the islands.
2010-05-27
International Nuclear Information System (INIS)
The aim of the safety calculation is to quantify through numerical modelling the radiological impact (molar flow, human dose) of a potential repository for radioactive waste on the Meuse/Haute Marne site at Bure. A selection process is underway for safety scenarios and their phenomenological and numerical conceptual models upstream from the safety calculation. This involves defining and quantifying the geometric and dimensional representations of the repository for each scenario plus the physical, mathematical and numerical models that reflect its behaviour and the uncertainties associated with all the parameters required to quantify the impact. A summary will be given of these various aspects. The numerical simulations are then performed on the Alliances platform which integrates the various computer codes required for the physical representation of the system. (authors)
2005-03-14
Revisited the mathematical derivation wall thickness measurement of pipe for radiography
Energy Technology Data Exchange (ETDEWEB)
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to ...
2007-07-01
Residual limb osteomyelitis: A case series from a national prosthetic centre
British Library Electronic Table of Contents (United Kingdom)
Purpose. To examine the impact of residual limb osteomyelitis (RLO) on the rehabilitation of lower limb amputees. Method. Retrospective review of the casenotes of patients with RLO. Information sought included details of amputation, clinical features of investigations for and management of RLO and its effect on rehabilitation. Results. There were seven transfemoral and three transtibial amputees. Indications for amputation were vascular disease in nine cases, trauma in one. In each case, delayed wound healing or residual limb pain prompted radiological, hematological and microbiological investigations. Average time between amputation and diagnosis was 187 days. One patient died before treatment commenced. Two transtibial amputees were treated with intravenous antibiotics while rehabilitati...
2009-01-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
International Nuclear Information System (INIS)
This report is the result of field work performed at the former White Point Nike Missile Site, San Pedro, California. The Hazardous Waste Remedial Actions Program tasked the Oak Ridge National Laboratory Pollutant Assessments Group in Grand Junction, Colo., with this project. The objective was to determine whether or not radioisotopes possibly associated with past Department of Defense (DOD) operations were present and within accepted background levels. The radiation survey was accomplished by performing three independent radiation surveys, both outdoors and indoors, and random soil sampling. Initially, the site was land surveyed to develop a grid block system. A background radiation investigation was performed out in the San Pedro area.
Radioactivity in local and imported kaolin types used in Egypt
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials are present in all geological rocks in varying amounts, they are easily mobilized in the environment, and can reach hazardous radiological levels under certain conditions, requiring precautions to be taken. The present study deals with 50 geological samples of local (Tushki and Kalabsha in upper Egypt) and imported (southeast Asia and Turkey) kaolin types. The samples were analyzed by gamma-ray spectroscopy using a HPGe detector. The activity concentrations of {sup 232}Th and {sup 238}U series and {sup 40}K and the contents (in ppm) are given. The radium equivalent activity varied from 187.8 to 10185.19 Bq/kg. {sup 137}Cs was found in a range of 0.23-8.53 Bq/kg, for the local samples. The kaolin in Tushki area was suitable for industrial use.
2004-01-01
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
International Nuclear Information System (INIS)
As to all sinter variations the microradiographic analysis showed that about 86 to 90 % of the implant surface were enclosed split-free with newly formed bone 16 weeks post operationem. A silicat salt addition of the test variation Ap_4_0KS_1_5 and Ap_4_0KS_3_0 did not cause a negative influence on bone regeneration. On the surface of all test implants a double layer was revealed radiologically, consisting of a 30 - 40 #mu#m thick bone near X-ray impermeable area and an X-ray permeable area of maximum 120 #mu#m thickness directed to the nucleus of the implant.
Energy Technology Data Exchange (ETDEWEB)
As to all sinter variations the microradiographic analysis showed that about 86 to 90 % of the implant surface were enclosed split-free with newly formed bone 16 weeks post operation. A silicate salt addition of the test variation Ap/sub 40/KS/sub 15/ and Ap/sub 40/KS/sub 30/ did not cause a negative influence on bone regeneration. On the surface of all test implants a double layer was revealed radiologically, consisting of a 30 - 40 ..mu..m thick bone near X-ray impermeable area and an X-ray permeable area of maximum 120 ..mu..m thickness directed to the nucleus of the implant.
1984-01-01
British Library Electronic Table of Contents (United Kingdom)
The treatment of acetabular bone defects presents a great challenge in revision total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiological outcome of revision THA using jumbo cups for acetabular reconstruction after applying the bone-grafting technique. We studied 17?patients with acetabular defects ranging from Type 2A to Type 3A according to Paprosky`s classification. According to the AAOS-score twelve patients were classified as Type II and five patients as Type III. Uncemented press-fit cups with an outer diameter larger than 64?mm were used in all cases. Fifteen patients received morselized bone allografts. In eight patients an additional screw fixation was necessary. The mean follow-up period was 82?months (range 33?149). The mean Harris Hip...
2008-01-01
International Nuclear Information System (INIS)
Chronic mesenteric arterial ischemia is an uncommon condition associated a high morbidity and mortality. It is most Commonly caused by atherosclerotic occlusive disease. Patients may suffer epigastric or periumbilical postprandial pain ten to thirty minutes after eating. A case of chronic mesenteric artery stenosis, the diagnosis was performance with colonoscopy and biopsy. We present a case report of a patient with chronic mesenteric ischemia. Mesenteric arteriography was performed and documented estenosis of the mesenteric superior artery. Then percutaneous arteriography with angioplasty and implant of stent was performed. The patients became completely asymptomatic and normal colon mucous is observed in control colonoscopy. The purpose of this report is to present the case endoscopy, clinic and radiological features and to describe the percutaneous angioplasty and implant of stent. We believe that angioplasty treatment offers and improvement in this pathology ...
Energy Technology Data Exchange (ETDEWEB)
The radiographs and initial clinical findings of 73 patients who had sustained trauma to the cervical spine without bony injury in vehicle collisions were reviewed. The patients were also re-examined clinically two years after the injury. Forty eight (65.8%) had abnormal radiographs at presentation - prevertebral soft tissue swelling in 15 (20.6%), degenerative changes in 15 (20.6%), and an angular deformity between two adjacent vertebral bodies in 27 (37.0%). The exact mode of inury is not associated with any specific radiographic appearance except that ''roll overs'' and side collisions are more likely to cause angulation in the cervical spine. (orig./GDG).
1988-10-01
International Nuclear Information System (INIS)
Nuclear forensics can provide information about the history, intended use and potentially the origin of nuclear or radioactive material. For these reasons, it is an important tool for improving nuclear security and combating illicit trafficking of nuclear and other radioactive materials. The IAEA is currently working on enhancing knowledge, techniques, procedures and cooperation in the field of nuclear forensics. Some of the work currently being undertaken by the IAEA includes the development of a five day training workshop on basic methods for radiological crime scene activities, to ensure adequate control of evidence, including for nuclear forensics purposes, a coordinated research project on the application of nuclear forensics in illicit trafficking, and a proposal for international cooperation with nuclear forensics databases and the development of guidelines for establishing databases. Nuclear forensics will continue to be an important topic for nuclear ...
Health and Safety Research Division progress report for the period April 1, 1987--September 30, 1988
Energy Technology Data Exchange (ETDEWEB)
The mission of the Health and Safety Research Division (HASRD) is to provide a sound scientific basis for the measurement and assessment of human health impacts of radiological and chemical substances. Our approach to fulfilling this mission is to conduct a broad program of experimental, theoretical, and field research based on a strong foundation of fundamental physical studies that blend into well-established programs in life sciences. Topics include biomedical screening techniques, biological and chemical sensors, risk assessment, health hazards, dosimetry, nuclear medicine, environmental pollution monitoring, electron-molecule interactions, interphase physics, surface physics, data base management, environmental mutagens, carcinogens, and tetratogens.
1989-03-01
Gas-cooled fast reactor safety - and overview and status of the U.S. program
International Nuclear Information System (INIS)
In the revised GCFR Safety Program Plan a quantitative risk limit line has been adopted to establish requirements for the safety related functions and systems. The risk limit line is derived from an interpretation of NRC established licensing requirements, including those for LMFBR's. Multiple barriers to the progression of accident sequences are defined in the form of six Lines of Protection (LOPs). LOPs-1 to 3 are dedicated to accident prevention and represent the normal operating systems, the dedicated safety systems and the inherent design features, respectively. LOPs-4 to 6 are dedicated to the mitigation of core melt accident consequences and include in-vessel accident containment, secondary containment integrity and radiological attenuation, respectively. Cumulative frequency limits and consequence limits are established for each LOP. Design features associated with each LOP are described and the results of supporting safety analyses are summarized. ...
1981-01-01
Fixation of heavy contaminants of a dirty bomb attack: Studies with uranium and metal simulants
British Library Electronic Table of Contents (United Kingdom)
Asphalt emulsions were evaluated as a means to immobilize radiological contaminants deposited on urban surfaces after a dirty bomb attack. Contaminated surfaces would be sprayed with thin coatings of asphalt emulsion to encapsulate the radioactive particles until the site can be safely remediated. This research investigated applications of an asphalt emulsion (Topein C, Encapco Technologies, LLC, Napa, CA) to treat (zero-valent) iron, lead, and uranium powders on various building material surfaces. Initial studies found that some of the building materials (limestone, concrete, and metal) reacted with the emulsion producing gas bubbles, which formed 0.001 to 1 cm vesicles in the cured asphalt emulsion. These vesicles, however, did not expose the building material surface, and the reaction a...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
1996-04-01
Environmental Radiation Effects: A Need to Question Old Paradigms
Energy Technology Data Exchange (ETDEWEB)
A historical perspective is given of the current paradigm that does not explicitly protect the environment from radiation, but instead, relies on the concept that if dose limits are set to protect humans then the environment is automatically protected as well. We summarize recent international questioning of this paradigm and briefly present three different frameworks for protecting biota that are being considered by the U.S. DOE, the Canadian government and the International Commission on Radiological Protection. We emphasize that an enhanced collaboration is required between what has traditionally been separated disciplines of radiation biology and radiation ecology if we are going to properly address the current environmental radiation problems. We then summarize results generated from an EMSP grant that allowed us to develop a Low Dose Irradiation Facility that specifically addresses effects of low-level, chronic irradiation on multiple levels of biological ...
2003-03-27
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
Effective dose equivalent concept in radiopharmaceutical dosimetry
Energy Technology Data Exchange (ETDEWEB)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective ...
1981-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
International Nuclear Information System (INIS)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective ...
Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology
Energy Technology Data Exchange (ETDEWEB)
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
1994-02-01
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distribution of stable iodine tablets is advised. PMID:20332130
2010-03-23
British Library Electronic Table of Contents (United Kingdom)
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distrib...
2010-01-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
1991-12-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
1991-01-01
International Nuclear Information System (INIS)
This paper explores the current trends in development of technology-neutral safety requirements to be used in the regulation of future nuclear power reactors and the role of the quantitative safety goals in the design of reactor safety systems. Establishing the requirements concerning the reliability of safety functions rather than on particular systems employed to achieve the functions, as well as the use of the recommendations of the International Commission on Radiological Protection (ICRP) on protection against potential exposure could form the basis of a technology-neutral framework for safety requirements on new reactor designs. Also it could contribute to international harmonisation of nuclear safety assessment practices as part of the licensing processes for future nuclear power plants. (author)
2009-10-12
Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip
Energy Technology Data Exchange (ETDEWEB)
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
1993-10-01
International Nuclear Information System (INIS)
Containment is considered as ultimate safety system and is designed to enclose whole reactor system and prevent the spread of active air-borne fission products. For Pressure and Temperature calculation, Design Basis Accident (Dba) is double ended break of reactor inlet header or main steam line break but activity release studies are done to access its performance following limiting design basis accident i.e. Loss of Coolant Accident (LOCA) and Emergency Core Cooling System (ECCS). In such accident scenario, the core is severely damaged and results in production of steam and hydrogen along with release of activity to containment environment. Containment functions are maintained in such accident, and radiological consequences are within the prescribed limits. (author)
2005-12-01
Case report 403: Extra-mammary Paget disease of the skin with disseminated skeletal metastases
Energy Technology Data Exchange (ETDEWEB)
The case is presented of a 64-year-old man who complained on admission of discomfort in the right shoulder at the time of excision of a large section of the axillary skin which contained extra-mammary Paget disease. Shortly thereafter, radiological studies of the humerus and scapula showed obvious malignant disease which proved to be metastatic upon biopsy of the humerus and pathological studies of the excised area of extra-mammary Paget disease in the axillary skin. The patient died twelve months after the diagnosis was established with widespread metastatic disease. The literature on the subject was reviewed and it was demonstrated that metastases to the skeleton from lesions of the skin are relatively rare. This case is exceptional because of the rapid fatal course and the extent of metastatic disease originating in extra-mammary Paget disease of the axillary skin.
1986-11-01
CLOSURE OF THE FAST FLUX TEST FACILITY (FFTF) HISTORY & STATUS & FUTURE PLANS
Energy Technology Data Exchange (ETDEWEB)
In 1993, the US Department of Energy (DOE) decided to shut down the Fast Flux Test Facility (FFTF) due to lack of national missions that justified the annual operating budget of approximately $88M/year. The initial vision was to ''deactive'' the facility to an industrially and radiologically safe condition to allow long-term, minimal surveillance storage until approximately 2045. This approach would minimize near term cash flow and allow the radioactive decay of activated components. The final decontamination and decommissioning (D and D) would then be performed using then-current methodology in a safe and efficient manner. the philosophy has now changed to close coupling the initial deactivation with final D and D. This paper presents the status of the facility and focuses on the future challenge of sodium removal.
2006-02-24
CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia
International Nuclear Information System (INIS)
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.
1999-04-01
Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures
International Nuclear Information System (INIS)
The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.
An overview of strategies to assess and rehabilitate former nuclear test sites. Keynote address
International Nuclear Information System (INIS)
Since the publication by the International Commission on Radiological Protection of revised recommendations which set out some general principles for intervention, some ideas have emerged which address interventions in the case of chronic exposure from contaminated lands. In the past there have been interventions proposed or carried out to rehabilitate land contaminated during the era of atmospheric nuclear weapon testing. Some of these interventions are reviewed in the context of these ideas and it is concluded that, by and large, reasonable outcomes have been achieved. The concept of a 'generic action level' (an effective dose of the order of 10 mSv#centre dot#a"-"1 to representative individuals in the critical group) may be useful in future to aid decision makers in determining whether intervention is appropriate. (author)
International Nuclear Information System (INIS)
In the safety assessment of a high-level radioactive waste (HLW) disposal system, it is required to estimate radiological impacts on future human beings arising from potential radionuclide releases from a deep repository into the surface environment. In order to estimated the impacts, a biosphere model is developed by reasonably assuming radionuclide migration processes in the surface environment and relevant human lifestyles. It is important to modify the present biosphere models or to develop alternative biosphere models applying the biosphere models according to quality and quantify of the information acquired through the siting process for constructing the repository. In this study, alternative biosphere models were developed taking geosphere-biosphere interface of marine environment into account. Moreover, the flux to dose conversion factors calculated by these alternative biosphere models was compared with those by the present basic biosphere models. (author)
2001-01-01
Advanced resin cleaning system
International Nuclear Information System (INIS)
Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)
2008-07-01
Abstracts of recent reports: Maryland power plant research program 1992 through 1997
Energy Technology Data Exchange (ETDEWEB)
The goals of the program include predicting the impact of proposed new generating facilities, evaluating proposed high voltage transmission lines, assessing the impact of existing generating facilities, forecasting future demand for electric power, and investigating numerous information gaps through a long-range research program. The Power Plant Assessment Division (PPAD) is responsible for all PSC licensing support, site specific research, and radiological monitoring. The list of reports summarizes information of over 190 technical publications that represent the Program`s formalized research and monitoring efforts over the last five years. Reports are listed in chronological order by topical heading.
1997-12-01
A review of 4 norm industries in Ireland
Energy Technology Data Exchange (ETDEWEB)
Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining ...
2006-07-01
British Library Electronic Table of Contents (United Kingdom)
The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten?years (ten to 18) and a mean age of 42?years (18?50). The overall revision rate at 14?years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11?mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclus...
2011-01-01
The effect of patient shield position on gonad dose during lumbar spine radiography
Energy Technology Data Exchange (ETDEWEB)
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...
2010-05-15
The effect of patient shield position on gonad dose during lumbar spine radiography
International Nuclear Information System (INIS)
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...
2010-05-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of the X-ray field and the beam direction of ...
2009-05-15
International Nuclear Information System (INIS)
For more than thirty years, the IAEA has published a set of documents aimed at the limitation of the radiation exposure of the population from various nuclear activities. In particular, in 1994 the IAEA published Technical Reports Series No. 364, Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Temperate Environments. Over the years, it has proved to be a valuable reference for radioecologists, modellers and authorities in Member States, and has been quoted in numerous impact assessments. Technical Reports Series No. 364 was based on a review of available data up to the end of 1992. However, a number of high quality critical reviews have been produced in recent years for some of the transfer parameter values which merit consideration. Thus, it was assumed that there is sufficient new information available to warrant reconsideration of a significant proportion of the values given in Technical Reports Series No. 364 and to initiate an updating of Technical ...
1993-04-05
Quality control in medical radiology using T.L.D
Energy Technology Data Exchange (ETDEWEB)
In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 {mu}Gy and 0.35 ...
2006-07-01
On the use of a prototype for data and information exchange for nuclear emergencies
Energy Technology Data Exchange (ETDEWEB)
Following the Chernobyl nuclear disaster, a considerable amount of effort and resources were allocated worldwide to designing and developing coherent and comprehensive decision support systems for nuclear or radiological emergency management. They range from simple radiological consequence assessment tools to more advanced systems, incorporating the assessment of countermeasures and their effectiveness. Furthermore, many of these systems have been tailored to answer to national emergency preparedness requirements and in some cases such as the R.O.D.O.S. and A.R.G.O.S. systems they have been successfully deployed in a number of countries. Thus, computer based decision support systems for nuclear emergencies are nowadays a reality in Europe, the US and Japan; however, there was a lack of an adequate information and data exchange mechanism that enabled them to function properly and serve the purpose that triggered their development. Within the ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
Objective: Solid pseudopapillary tumor of the pancreas (SPTP tumor) is a rare pancreatic neoplasm with low malignant potential, which usually affects female patients in the second or third decades of life. It is a non-functional, slow-growing neoplasm that very often reaches considerable size before the first symptoms appear. Symptomatology is frequently related to tumor size. Surgical excision is usually curative in most cases. Infrequently the tumor can appear in male patients or in aged women, which can make the diagnosis more difficult. Some patients develop liver metastases in the follow-up that can be resected. Our purpose is to review the radiological and pathological findings of SPTP with emphasis on these infrequent cases. Subjects and methods: The medical records and radiological findings of patients who underwent surgery for SPTP between 2000 and 2005 were retrospectively reviewed. Study eligibility required that patients had ...
2006-04-15
International Nuclear Information System (INIS)
Objective: Solid pseudopapillary tumor of the pancreas (SPTP tumor) is a rare pancreatic neoplasm with low malignant potential, which usually affects female patients in the second or third decades of life. It is a non-functional, slow-growing neoplasm that very often reaches considerable size before the first symptoms appear. Symptomatology is frequently related to tumor size. Surgical excision is usually curative in most cases. Infrequently the tumor can appear in male patients or in aged women, which can make the diagnosis more difficult. Some patients develop liver metastases in the follow-up that can be resected. Our purpose is to review the radiological and pathological findings of SPTP with emphasis on these infrequent cases. Subjects and methods: The medical records and radiological findings of patients who underwent surgery for SPTP between 2000 and 2005 were retrospectively reviewed. Study eligibility required that patients had ...
2006-04-01
International Nuclear Information System (INIS)
A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head collapse on average ...
Assessing radiologic risk for population due to human activities
International Nuclear Information System (INIS)
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. Presence of noxious materials such as heavy ...
2002-09-06
Energy Technology Data Exchange (ETDEWEB)
Hystreosalpingogram of 375 patients with infertility were reviewed with reference to radiological feature of each pathology and a comparative study of hysterosalpingography and laparoscopy in 36 patients was presented. This results were as follows;1. In 375 cases of infertility, 191 cases (50.9%) were primary infertility and 181 cases (49.1%) were secondary infertility. 2. The peak age distribution was 26 to 30 year old group in 211 cases (56.3%), and the peak duration of infertility was less than 3 years in 256 cases (68.3%). 3. Abnormal uterine findings were 115 cases (30.7%) and there were 73 cases of filling defects, 13 cases of irregularity, 12 cases of uterine flexion, 11 cases of congenital anomaly, and 9 cases of hypoplasia among them. 4. Abnormal tubal findings were 196 cases (52.3%) and there were 103 cases of simple obstruction, 69 cases of hydrosalpinx, and 50 cases of peritubal adhesion among them. 5. Intravasation of contrast media was noted in 42 ...
1984-09-15
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
