WorldWideScience
 
 
1

Non cardiopatic and cardiopatic beta thalassaemic patients: quantitative and qualitative cardiac iron deposition evaluation with MRI; Pazienti {beta} talassemici non cardiopatici e cardiopatici: valutazione quantitativa e qualitativa del deposito di ferro cardiaco con RM  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, the myocardial and skeletal muscle signal intensity (SI), the myocardial/skeletal muscle signal intensity radio (SIR) and the SI average of the ...

2005-02-01

2

Osteoporosis and prevention. Assessment of mineral density, geometry and biomechanics of bone by means of peripheral quantitative Computed Tomography (pQCT) in premenopausal women assuming phytoestrogens; Osteoporosi e fitoestrogeni: valutazione della densita' minerale ossea mediante tomografia computerizzata quantitativa periferica nelle donne lattoovovegetariane nella premenopausa  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe the noninvasive assessment of bone mineral density, geometrical and biochemical properties in premenopausal women with dietary intake of phytoestrogens and comparison of these parameters with those of age-matched female subjects with Mediterranean dietary intake lacking in these substances. Volumetric cortical, trabecular and total mineral density and bone geometrical properties were evaluated with peripheral quantitative computed tomography (pQCT) at the distal radius of the non dominant forearm. pQCT showed higher bone mineral density (total and trabecular) and SSI values in premenopausal with dietary intake of phytoestrogens. Despite the lack of statistical significance, these preliminary results, should further support the few literature findings about the potential role of phytoestrogens consumption in preventing trabecular bone loss. However, further studies are warranted to evaluate definitively postmenopausal osteoporosis. [Italian] Scopo del ...

2000-04-01

3

Decision making information systems and data base management; Applicazioni dei sistemi di supporto alle decisioni manageriali in un ente fortemente decentrato. Sviluppo di un prototipo per la valutazione di nuovi progetti  

Energy Technology Data Exchange (ETDEWEB)

In these years Information Technology has been used in activities that require an intelligent intervention. In this context take placing Decision Support Systems, since they use Information Technology to support users in decision processes, that is problems of logical level greater then problems normally treated by traditional information systems. The purpose of this work is to describe Decision Support Systems specifying what they are, their functionally and structure, identifying, furthermore, user types referred to and interaction modality between them; and to present a prototype of these systems. From a preliminary analyses phase of ENEA being and its Information Systems to understand which topics can be supported by systems of this type, it deals with one of these topics: weighing of new project, finding parameters, or key quantity, that affect and determine decisions. It describes, then, models, conceived form parameters, that permit to the user, through a simple representation ...

1997-01-01

4

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo differenti procedure ablative percutanee  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in 38%. Morphology was unchanged in 63% of ...

1999-12-01

5

CT assessment of thoracic gunshot wounds. Our personal experience; Ruolo della Tomografia Computerizzata nelle lesioni da arma da fuoco del torace. Esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

CT is a valuable tool in assessing thoracic gunshot wounds. CT is also the method of choice in emergency, because it permits rapid depiction of bullet damage to the chest and to other body districts. This in turn permits correct assessment of the main thoracic injuries, plus adequate and prompt planning of surgical treatment or support intensive care. It is reported on the role of CT in diagnosing the complex pleuropulmonary, cardiovascular and thoracic wall injuries caused by gunshot wounds, with their specific and acute signs which differ greatly fro those of other types of chest trauma. In the last 4 years, it was observed an amount of 76 cases of gunshot injury, twenty-six of them involved the chest. The patients, 25 men and 1 woman (mean age: 32 years, range: 17-48), were all submitted to emergency CT with iv contrast agent injection and the CT-angiography technique. The reanimator was always presented to monitor the patients' vital functions and shock state. CT of the ...

1999-11-01

6

Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemoembolization; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo chemioembolizzazione  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to global chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower than 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyper attenuation in the ...

2000-06-01

7

Computed Tomography of the diabetic kidney; La Tomografia Computerizzata nello studio del rene diabetico  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to investigate whether any morphometric or densitometric are detectable in the kidneys of type 2 diabetic patients. 40 diabetic patients were examined and of 20 non-diabetics (the control group) were submitted to triphasic helical CT for different abdominal conditions. The type 2 diabetic patients were 23 men and 17 women, mean age 62 years, while the nondiabetic controls were 12 men and 8 women, mean age 58 years. All the CT images were analyzed using the Multiplanar Reconstruction (MPR) software. It was evaluated morphometric features, such as the presence of parenchymal or vascular calcifications, axial and coronal renal diameters, coronal renal area, and cortico medullary ratio, and densitometric and functional features, such as unenhanced renal density, cortical and medullary density in the arterial phase, parenchymal density in the nephrographic phase, and contrast elimination. It was also compared the results in the subgroups of patients with those in ...

2000-02-01

8

Radiofrequency ablation of hepatocellular carcinoma extended into the portal vein: Preliminary results  

British Library Electronic Table of Contents (United Kingdom)

SommarioScopo In questo studio riportiamo i dati relativi all'ablazione percutanea con Radiofrequenza (RF) di HCC e trombosi neoplastica dei vasi portali. Pazienti e metodi Dieci pazienti (pz) cirrotici, 7 maschi e 3 femmine, eta media 68 anni, con 10 noduli di HCC e trombosi neoplastica dei vasi portali sono stati sottoposti ad ablazione percutanea con RF del trombo neoplastico e dell'HCC. La RF veniva ritenuta efficace quando alla TC con mdc si osservava la necrosi completa dell'HCC e al Color Doppler si osservava la ricanalizzazione completa dei vasi portali. Risultati La necrosi completa dell'HCC e la ricanalizzazione completa dei vasi portali si osservava in 7 (70%) dei 10 pazienti. Nei rimanenti 3 (30%) la necrosi dell'HCC e la ricanalizzazione dei vasi portali non risultavano comple...

2009-01-01

9

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience; Ruolo della Tomografia Computerizzata Spirale e Multistrato nello studio delle lesioni traumatiche e spontanee dell'esofago: nostra esperienza  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...

2005-03-01

10

Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation; Valutazione del fattore <<N>> nel carcinoma polmonare non a piccole cellule. Correlazione tra tomografia computerizzata e anatomia patologica  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, independent of size, the following signs were found: central hypo ...

2000-05-01

11

Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings; Traumi epatici da lesioni penetranti. Miscellanea, casistica personale, aspetti clinici e con Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT was performed from the ...

2000-12-01

12

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than ...

2007-08-21

13

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing ...

2007-08-21

14

Separate collection in Italy. A comparison between two case-studies; Raccolta differenziata in Italia. Due realta' a confronto  

Energy Technology Data Exchange (ETDEWEB)

In this paper two MSW management case-studies are analyzed: the Bressanone and Trento cases (two italian towns). Separate collection solution are analyzed in a great detail. The aim to point out data and solutions useful to obtain the target of the separate collection set in the Ronchi's Decree. A comparison difficulties and unclear aspects of Rochi's Decree are also analyzed in the second part of this paper. [Italian] Nel presente studio e' stata effettuata un'analisi tecnico-economica dei sistemi di gestione dei rifiuti urbani e raccolta differenziata dei comuni di Bressanine e Trento con l'obiettivo di produrre dati di riferimento sufficientemente affidabili, utili all'ottimizzazione dei sistemi stessi nonche' all'individuazione delle soluzioni tecniche necessarie al raggiungimento degli obiettivi di raccolta differenziata ...

1999-04-01

15

Bone geometry, biomechanics, and mineral content of the distal radius in uremic patients with severe hyperparathyroidism; Valutazione delle proprieta' geometriche, biomeccaniche e osteodensitometriche del radio ultradistale mediante tomografia computerizzata quantitativa periferica nei pazienti uremici affetti da iperparatiroidismo grave  

Energy Technology Data Exchange (ETDEWEB)

Bone integrity and mineral status were studied with a noninvasive method in uremic patients with severe secondary hyperparathyroidism undergoing maintenance hemodialysis. [Italian] Gli autori propongono un metodo non invasivo per studiare la densita' minerale e le caratteristiche geometriche e biomeccaniche dell'osso nei pazienti uremici affetti da iperparatiroidismo secondario grave.

1999-04-01

16

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)

2009-11-01

17

Compacting high voltage transmission lines in view of dielectric and corona noise constraints. Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona  

Energy Technology Data Exchange (ETDEWEB)

The paper reports the results of the studies performed at the Electric Research Center of ENEL (Italian National Electricity Board) in the field of compacting high voltage transmission lines, from the point of view of dielectric and corona noise constraints. The results of switching impulse withstand voltage tests, performed on typical compact line insulation configurations, are given and optimization criteria of such insulation configurations in relation to switching impulse are outlined. The constraints regarding surface withstand voltage in polluted conditions of the above insulations are analyzed and the possibility of reducing their dimensions by using unconventional insulation materials is considered. Finally, evaluations of corona noise in the case of optimization of the line encumbrance from the point of view of dielectric constraints are given.

1993-05-01

18

Degradation of recalcitrant organic pollutants by mixed catalysts; Degradazione di inquinanti organici recalcitranti mediante catalizzatori misti  

Energy Technology Data Exchange (ETDEWEB)

The photodegradation of two well known recalcitrant compounds was studied. At this aim, a photosystem constituted by titanium dioxide and polyaniline, both immobilised in a PVC membrane, and a sunlight simulating irradiation source was used. The optimisation of the experimental conditions, ph, ionic strength and, when operating on soils, humic acid concentration, allowed the photodegradation of Paraquat at a nearly 100% extent, while, an oxidation by hypochlorite was needed to degrade cyanuric acid. [Italian] E' stata studiata la fotodegradazione di due composti notoriamente recalcitranti a questo tipo di rimozione. Con un sistema fotocatalitico costituito da biossido di titanio e polianilina immobilizzati in una membrana di PVC ed operando con luce solare simulata e' possibile, ottimizzando le condizioni sperimentali di pH, forza ionica e - operando su terreno - concentrazione di acidi umici, ottenere la degradazione del paraquat fino a valori ...

2001-05-01

19

Mesenchymal tumors of the pancreas. CT patterns; Tumori mesenchimali del pancreas: aspetti con tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this item is to report the CT patterns of pancreatic mesenchymal lesions and to investigate the capabilities and limitations of this technique in terms of characterization. In selected cases, CT can provide virtually diagnostic information (lipoma and teratoma), or at least highly suggestive findings (NHL, plexiform neurofibroma, lymphangioma). Moreover, knowledge of the variable morphostructural patterns of mesenchymal hisototypes (SCH, Sarcoma etc.) permits to include them in the differential diagnosis of pancreatic masses. [Italian] Scopo di questo rapporto e' descrivere gli aspetti semeiologici dei tumori mesenchimali del pancreas con la TC verificandone le possibilita e i limiti per la caratterizzazione. Pur nella rarita' dei reperti considerati, la TC puo' consentire l'effettiva caratterizzazione in alcuni casi (lipoma, neurofibroma plessiforme, linfangioma) o includere anche istotipi meno ...

1999-10-01

20

CT findings after normal and unsuccessful functional endoscopic sinus surgery; Ruolod della tomografia computerizzata dopo chirurgia funzionale dei seni paranasali: rilievi normali e valutazioni degli insuccessi chirurgici  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates the functional endoscopic sinus surgery with the Messer-linger's technique which treats benign or inflammatory diseases of paranasal sinuses resistant to medical therapy. The goal of this type of surgery is to open the obstructed sinus ostia and restore normal aeration and mucociliary clearance. The computerized tomography permits an accurate assessment of extension and results of functional endoscopic sinus surgery. [Italian] L'articolo discute l'uso della tecnica di Messerklinger nella chirurgia funzionale endoscopica dei seni paranasali per il trattamento delle malattie benigne e delle infiammazioni croniche. Essa disostruisce gli osti sinusali ripristinando la normale areazione e la pulizia mucociliare. La tomografia computerizzata consente di valutare l'estensione e i risultati del trattamento chirurgico funzionale, soprattutto nel caso di insuccesso terapeutico, rilevando malattia nasosinusale ...

1999-09-01

 
 
 
 
21

Anatomic and radiologic correlations in spontaneous hematomas of the rectus abdomninis muscles; Correlazioni anatomo-radiologiche negli ematomi spontanei dei muscoli retti dell'addome  

Energy Technology Data Exchange (ETDEWEB)

Rectus sheath hematomas are a frequent but sometimes misdiagnosed disease in patients under anticoagulative drugs, hemodialysis, or simply in the elderly. The most frequent localization is in the lower part of the abdomen: the explanation lies in the anatomy of the abdominal wall, especially in the arcuate line of the rectus sheath. Aim of this work is to explain the reason of the almost constant location correlating the anatomy with the CT features. The rectus abdominis muscle lies between the aponeuroses of the transverse and oblique muscles which form the so called rectus sheath. This arrangement is found from the costal arch to a level approximately between the umbilicus and the pubic symphisis, where the rear layer of the rectus sheath ends with a curved edge, called the arcuate or semicircular line of Douglas. Beneath this line the aponeuroses of the three muscles pass in front of the rectus which is separated from the peritoneum only by the fascia trasversalis, a thin connective ...

2000-06-01

22

Lung studies with spiral CT. pitch 1 versus pitch 2; Confronto tra diversi parametri (pitch 1 e 2) nello studio del polmone con Tomografia Computerizzata spirale  

Energy Technology Data Exchange (ETDEWEB)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality. [Italian] Nella Tomografia Computerizzata (TC) spirale il rapporto tra la distanza percorsa dal lettino portapaziente in una rotazione e lo spessore nominale dello strato, entrambi espressi in millimetri, si definische pitch. Se i due valori del rapporto coincidono si avra' pitch uguale a 1, mentre raddoppiando la distanza percorsa dal lettino portapaziente, per il medesimo spessore nominale, conseguentemente raddoppia il pitch (pitch 2). Eseguire gli esami TC spirale utilizzando pitch 2, consente di ridurre la durata dell'esame, la dose di esposizione, il ...

1999-03-01

23

The carrying out process of Kyoto Protocol in Italy. Methods, scenarios and policy evaluation; Il processo di attuazione del Protocollo di Kyoto in Italia. Metodi, scenari e valutazione di politiche e misure  

Energy Technology Data Exchange (ETDEWEB)

This paper reports some technical contributes related to the Kyoto Protocol and its application in Italian decision making policy. [Italian] Il presente volume raccoglie una decina di contributi tecnici originariamente preparati o commissionati dall'ENEA, Ente Nazionale per le Nuove Tecnologie, l'Energia e l'Ambiente, in vista della Conferenza Nazionale Energia e Ambiente. Questa fotografia di una situazione in rapida evoluzione e' stata preparata da esperti del settore che contribuiscono a redigere il materiale tecnico di base utilizzato dai negoziatori nazionali durante le trattative internazionali e dai responsabili nazionali per avviare il processo di presa di decisioni in materia.

2000-07-01

24

Malignant pulmonary lesion. Possible causes of CT misdiagnosis; Possibilita' di falsi negativi nella diagnosi delle neoplasie polmonari con Tomografia Computerzzata  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to describe the radiological appearance of overlooked malignant pulmonary lesions at CT and to analyze the reasons of misdiagnosis. Ten patient with pulmonary lesion (PML) overlooked at forst CT examination were selected among patients with lung cancer. Endobronchial location of the tumors and their small size were the most frequent causes of misdiagnosis of PML at chest CT in the series. However, a systematic evaluation of CT scans can reduce the percentage of missed lesions. [Italian] Scopo del presente lavoro e' di descrivere le caratteristiche radiologiche delle lesioni polmonari maligne non identificate con la Tomografia Computerizzata (TC) e definire le possibili cause di errore. Sono stati esaminato 10 pazienti con tumore polmonare. Le sedi endobronchiale e centrale nonche' le piccole dimensioni delle lesioni polmonari maligne rappresentano le cause piu' frequenti di errore diagnostico della TC. La ...

1999-06-01

25

CT diagnosis of subphrenic abscess after splenectomy for trauma; Ruolo della tomografia computerizzata nella valutazione degli ascessi subfrenici dopo splenectomia post-traumatica  

Energy Technology Data Exchange (ETDEWEB)

The paper studies subphrenic inflammatory abscesses and splenic fluid collections after splenectomy for trauma. These complications may appear early or late postoperatively; they are easily demonstrated with computerized tomography, which permits accurate spatial assessment of the lesions and appropriate treatment with percutaneous drainage. It has been also investigates the diagnostic accuracy of the CT in subphrenic inflammatory conditions after emergency splenectomy for traumatic spleen rupture and found that CT is a precious tool for rapid and easy diagnosis and follow-up of subphrenic abscesses treated with percutaneous drainage. [Italian] Scopo del lavoro e' di valutare il ruolo della tomografia computerizzata nelle flogrosi subfreniche secondarie a splenectomia d'urgenza per rottura traumatica della milza, documentando come tale metodica risulti accurata nel diagnosticare e monitorare in modo semplice e rapido l'evoluzione e il controllo degli ascessi ...

1999-09-01

26

Abdominal adipose tissue distribution in obese children. US versus CT measurements; Valutazione della distribuzione del tessuto adiposo addominale nei bambini obesi. Confronto tra ecografia e Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Computed Tomography (CT) and, more recently, ultrasound (US), have proved excellent tools for quantifying adipose tissue distribution. Body fat distribution is an important factor in the treatment of obesity and its complications. In this work it is investigated the correlation between CT and US measurements in pediatric obesity. Forty obese children and adolescents aged 4.1-14.8 years were submitted to CT and US. Intra-abdominal, subcutaneous and total body fat were calculated (in cm{sup 2}), with the CT image analysis software. The rectus muscle-spine and rectus muscle-aorta distances, as indicative of visceral fat thickness, were measured on US images with(out) compression. The distance between skin fat and fat-rectus muscle interfaces was measured as subcutaneous fat thickness. US-CT findings have been compared with other morphometric variables-i.e., patient's (ideal) body weight and skin fold measures. A statistically significant correlation was found between the CT ...

1999-12-01

27

Suburban amoebiasis. CT and US findings and percutaneous treatment of amoebic liver abscess; Amebiasi sub-urbana: aspetti diagnostici con tomografia computerizzata ed ecografia e trattamento percutaneo degli ascessi amebici del fegato  

Energy Technology Data Exchange (ETDEWEB)

The study reports ultrasonography and computerise tomography findings in 16 patients with amoebic abscesses, 12 of whom lived in a temperate peripheral area north-east of Naples (Italy). All patients have a clinical-diagnostic condition called sub-urban amoebiasis. The personal experience with the US guided therapeutic drainage of amoebic abscess with repeated cavity washing, which is important for positive parasitology. Combined US and CT assessment facilitated the diagnosis of amoebiasis and its differentiation from pyogenic abscess and hepatoma. [Italian] La colonizzazione epatica rappresenta la localizzazione piu' comune dell'amebiasi extraintestinale e gli ascessi epatici ne costituiscono la manifestazione piu' frequente sviluppandosi nel 3-9 % dei pazienti affetti da infezione parassitaria. Diversi studi confermano che la terapia medica dell'amebiasi risulta piu' efficace quando viene associato il drenaggio ...

2000-03-01

28

CT colonoscopy with volume rendering. Results and comparison with endoscopy and surgery; Cononscopia con tomografia computerizzata con ricostruzioni di volume: risultati e confronto con endoscopia  

Energy Technology Data Exchange (ETDEWEB)

The paper reports the results of a preliminary experience with volume rendering technique of virtual computerized tomography colonoscopy and compares it with endoscopy and surgery showing its capability in detecting colon and rectal cancers. [Italian] Scopo del lavoro e' riportare l'esperienza personale preliminare nell'uso della colonscopia TC virtuale confrontando i risultati con quelli dell'endoscopia e dei riscontri operatori, dimostrandone l'efficacia nella diagnosi delle malattie tumorali del colon-retto.

1999-09-01

29

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto anziano; nonostante il notevole perfezionamento delle tecniche di ...

1999-04-01

30

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography; Sindrome da immunodeficienza acquisita e malattie polmonari da Mycobacterium xenopi. Ruolo della Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with aspecific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral reticular interstitial ...

2000-06-01

31

Quality controls in radiotherapy. From experiences of the first course-debate; Controlli di qualita' in radioterapia. Dalle esperienze del primo corso-dibattito  

Energy Technology Data Exchange (ETDEWEB)

The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure. [Italian] Questo documento e' dedicato al primo corso-dibattito sui controlli di qualita' in radioterapia svoltosi a Roma il 3-4 dicembre 1998 e il 3-5 maggio 1999 in collaborazione tra l'Istituto Superiore di Sanita' e l'Istituto Regina Elena. Esso presenta gli argomenti ritenuti critici per l'assicurazione di qualita' in radioterapia in relazione all'intera procedura radioterapica, in base alle esperienze dei partecipanti.

2000-07-01

32

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast images are extracted from experimental projection images by an algorithm similar to diffraction-enhanced imaging ...

2006-08-01

33

Analytical surveys on water quality of Trasimeno Lake: Definition of trophic levels; Indagine sulla qualita` delle acque del Lago Trasimeno: Definizione dei livelli trofici  

Energy Technology Data Exchange (ETDEWEB)

The previous judgment of eutrophic state, once proposed for the Trasimeno Lake (Umbria region, Italy), has been revised. According to Vollenweider-OECD classification criterion, the lake waters are at present to be classified as mesotrophic waters, with phosphorus limitation. However this level of moderate productivity results to be conditioned by the hydrochemical characteristics of the lake waters, that control phosphorus concentrations independently from the loading coming from the basin, and prevent dangerous and massive algal blooms. Different processes of chemical nature, regulating the phosphorus amount in the lake waters, are then reviewed: adsorption of P/P0(4) onto suspended materials, particularly clay mineral particles, and direct precipitation as hydroxylapatite or co-precipitation with carbonates, are found to be the principal mechanisms that determine chemical removal of phosphorus from the water column. A preliminary mass balance of phosphorus subtracted from the system ...

1995-06-01

34

Abdominal masses in the pediatric age. Characterization by CT guided fine needle aspiration biopsy; Masse addominali nell'eta' pediatrica. Caratterizzazione mediante biopsia computerizzata con ago sottile guidata con Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age. [Italian] Sono noti i vantaggi che la biopsia percutanea con ago sottile guidato con TC puo' apportare per la diagnosi delle lesioni espansive addominali, soprattutto se confrontata con procedure piu' invasive come la laparatomia esplorativa. Questo tipo di metodica e' attalmente poco utilizzato nel caso di pazienti pediatrici a causa della scarsa collaborazione e dei rischi associati. Gli autori valutano l'applicabilita' di tale procedura nell'eta' pediatrica alla luce delle propria esperienza.

1999-04-01

35

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma; Integrazione delle immagini della Tomografia Computerizzata con emissione di fotone singolo in un sistema commerciale per l'elaborazione dei piani di radioterapia. Applicazione all'irradiazione conformazionale del carcinoma polmonare  

Energy Technology Data Exchange (ETDEWEB)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e l'impiego di immagini provenienti da altre ...

1999-04-01

36

Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications; Tomografia computerizzata con Dentascan del canale incisivo mandibolare. Anatomia radiologica e implicazioni terapeutiche  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth. [Italian] Scopo di questo lavoro e' sottolineare l'importanza di rilevare e segnalare la visibilita' con Tomografia Computerizzata del canale incisivo mandibolare, struttura anatomica al cui interno decorre un fascio vasculo nervoso e percio' di ...

1999-11-01

37

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies; Valutazione quantitativa dell`enfisema polmonare mediante Tomografia Computerizzata. Confronto tra il punteggio visivo con alta risoluzione nell`inspirazione, maschera della densita` automatica con Tomografia Computerizzata spirale nell`espirazione ed esami funzionali respiratori  

Energy Technology Data Exchange (ETDEWEB)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas ...

1997-04-01

38

The microzooplankton and its distribution in different aquatic environment; Il microzooplancton e la sua distribuzione nei diversi ambienti  

Energy Technology Data Exchange (ETDEWEB)

In this work some examples of studies performed with the use of microzooplankton as biological indicator are reported. [Italian] Scopo del lavoro e' quello di dimostrare come lo studio della distribuzione del microzooplancton in ambienti aquatici, possa permettere la caratterizzazione trofica dell'ambiente oggetto di studio. Il microzooplancton, infatti, essendo un componente fondamentale della catena trofica di differenti ambienti acquatici, puo' essere considerato un buon {sup i}ndicatore biologico{sup .} E' quindi riportata un'ampia ed approfondita analisi sistematica, necessaria al fine di individuarne le diverse specie dalla cui presenza (oltreche' dal numero degli esemplari) e' possibile desumere lo stato chimico-fisico e trofico di un determinato ambiente acquatico. Sono poi indicati i diversi metodi per il campionamento, la conservazione, la concentrazione ed il conteggio del microzooplancton; in particolare per la ...

1999-07-01

39

Photovoltaic plants in the electronic system; Gli impianti fotovolatici nel sistema elettrico. Stato e prospettive  

Energy Technology Data Exchange (ETDEWEB)

The article provides a 1998 updated picture of Italy's and the world's photovoltaic market in terms of produced modules and total installed capacity, as well as market growth forecasts up to 2010. After a short description of the state-of-the-art of cell and module manufacturing, ana analysis of the cost of producing a photovoltaic kw is reported for different plant types: stand-alone plants with energy storage batteries, plants connected to low low voltage networks or intended for supporting medium voltage networks, hybrid plants with diesel sets. The article is concluded by illustrating ENEL's (Electric Power Production Company) engagement in the field of photovoltaic solar energy as regards theoretical studies, research and testing of new technologies, and installing plants; over nearly twenty years of activity, ENEL has designed and built a few hundreds of photovoltaic plants for a total capacity of about 4.000 kw, and is currently in the process of ...

1999-04-01

40

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ricerca in biofisica e biomedicina. Il ...

1997-12-01

 
 
 
 
41

Final environmental impact statement. Waste Isolation Pilot Plant  

Energy Technology Data Exchange (ETDEWEB)

In accordance with the National Environmental Policy Act (NEPA) of 1969, the US Department of Energy (DOE) has prepared this document as environmental input to future decisions regarding the Waste Isolation Pilot Plant (WIPP), which would include the disposal of transuranic waste, as currently authorized. The alternatives covered in this document are the following: (1) Continue storing transuranic (TRU) waste at the Idaho National Engineering Laboratory (INEL) as it is now or with improved confinement. (2) Proceed with WIPP at the Los Medanos site in southeastern New Mexico, as currently authorized. (3) Dispose of TRU waste in the first available repository for high-level waste. The Los Medanos site would be investigated for its potential suitability as a candidate site. This is administration policy and is the alternative preferred by the DOE. (4) Delay the WIPP to allow other candidate sites to be evaluated for TRU-waste disposal. This environmental impact statement is arranged in ...

1980-10-01

42

Contrast-enhanced helical CT in sigmoid diverticulitis. Findings and impact on diagnosis and treatment; Ruolo della tomografia computerizzata spirale nella diverticolite del sigma e implicazioni diagnostico-terapeutiche  

Energy Technology Data Exchange (ETDEWEB)

Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e dal confronto dei reperti TC con i ...

2000-03-01

43

Basic distribution free identification tests for small size samples of environmental data  

Energy Technology Data Exchange (ETDEWEB)

Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data. [Italiano] Nell`analisi di dati ambientali ricorre spesso il caso di dover sottoporre a test l`ipotesi di provenienza di due, o piu`, insiemi di dati dalla stessa popolazione. Tipicamente i dati disponibili sono ...

1998-01-01

44

Monte Carlo analysis of radiative transport in oceanographic lidar measurements  

Energy Technology Data Exchange (ETDEWEB)

The analysis of oceanographic lidar systems measurements is often carried out with semi-empirical methods, since there is only a rough understanding of the effects of many environmental variables. The development of techniques for interpreting the accuracy of lidar measurements is needed to evaluate the effects of various environmental situations, as well as of different experimental geometric configurations and boundary conditions. A Monte Carlo simulation model represents a tool that is particularly well suited for answering these important questions. The PREMAR-2F Monte Carlo code has been developed taking into account the main molecular and non-molecular components of the marine environment. The laser radiation interaction processes of diffusion, re-emission, refraction and absorption are treated. In particular are considered: the Rayleigh elastic scattering, produced by atoms and molecules with small dimensions with respect to the laser emission wavelength (i.e. water molecules), ...

2001-07-01

45

Gastric stromal tumors. CT findings; Tumori stromali gastrici. Aspetti con Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Gastric stromal tumors are an ill-defined group of lesions arising from muscle wall cells and characterized by extremely variable biological patterns. Thanks to modern immunohistochemical and ultrastructural techniques, four main classes of these lesions have been identified, namely: (1) tumors with differentiation toward smooth muscle cells; (2) tumors with differentiation toward neural elements; (3) tumors with differentiation toward neural elements; (3) tumors with dual differentiation toward either cell type. It was investigated the yield of CT in diagnosing and characterizing gastric stromal tumors. It was retrospectively reviewed the CT findings of 38 patients (15 men and 23 women; mean age 51 years) with pathologically proven gastric stromal tumors, namely 31 of myoid origin, 4 of neural origin, 2 with both muscle and neural differentiation, 1 lacking differentiation with either cell type. The myoid tumors involved gastric fundus in 9/13 and 5/7 benign lesions and lesions with ...

2000-02-01

46

Gunshot wounds to the head. Correlations between CT and clinical findings, neurosurgical treatment and long-term sequels; Traumi cranio-encefalici da proiettile: correlazione tra tomografia computerizzata, clinica, trattamento neurochirurgico e sequele a distanza  

Energy Technology Data Exchange (ETDEWEB)

With the aim of demonstrating the usefulness of computerised tomography (CT) findings in the planning of brain neurosurgery in gunshot victims, for prompt and successful treatment, 30 patients with brain gunshot wounds were examined with CT over 5 years. The mortality rate of firearm wounds of the skull base was 34% higher than that of the hemisphere; this is due to carotid hemorrhage and midbrain damage. Such traumas require emergency radiological diagnosis and neurosurgical treatment because of their severity and early irreversible complications. Complex operations and skilled surgeons may prevent disabling postoperative sequels. CT findings are indispensable and must be correctly interpreted. The radiologist and the neurosurgeon must collaborate closely and both must consider several diagnostic factors affecting surgical planning. [Italian] Scopo dello studio e' stato quello di dimostrare l'utilita' della semeiologia della tomografia computerizzata in ...

2000-03-01

47

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline ...

2000-09-01

48

CT in the study of thoracic-pulmonary complications after liver transplantation; La Tomografia Computerizzata nello studio delle complicanze toraco-polmonari dopo trapianto del fegato  

Energy Technology Data Exchange (ETDEWEB)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) examinations had been performed with ...

2000-12-01

49

CT assessment of blunt diaphragmatic injuries. A retrospective study on 35 cases; Sensibilita' diagnostica della Tomografia Computerizzata nei traumi chiusi del diaframma. Studio retrospettivo di 35 casi consecutivi  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this work is to evaluate the effectiveness and role of CT in blunt diaphragmatic injuries by reviewing our 8-year experience. It is reviewed the preoperative CT findings of 35 patients with surgically confirmed diaphragmatic rupture. Surgical repair was performed in the acute setting (within 12 hours of trauma) in 22 cases, and late (8 months-5 years) in 13 cases. Twenty-eight patients (80%) were examined with conventional CT and 7 (20%) with Helical CT. Of the 13 patients examined long after trauma, the left hemi diaphragm was ruptured in 12 cases (with visceral herniation in 4), and the right hemi diaphragm in 1, with no herniation. The diaphragmatic rent was found in the dome (15 cases, 43%), muscolotendinous junction (11 cases, 31%), muscular portion (8 cases, 23%), and at the muscular attachments on the ribs (1 case, 3%). As for the site of diaphragmatic injury, CT never depicted the diaphragmatic rent in the dome and at the muscolotendinous junction (74%), not even ...

2000-02-01

50

Banks, environment and sustainable development. EMAS regulation n. 761/2001/EC applied to the financial institutions; Banche, ambiente e sviluppo sostenibile l'adesione degli istituti finanziari al regolamento EMAS  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to characterize the role of the financial institutions in achieving sustainable development meaning a process of development which leaves at least the same amount of capital, natural and man-made, to future generations as current generations have access to. This makes it clear that sustainable development is about capital allocation and thus should be at the core of financial markets activity. On a more practical level the different ways banks affect environment are analyzed: as investors - supplying the investments with environmental perspective; as lenders - developing new financial products to encourage sustainable development; as valuers - estimating risks and opportunities in project-financing; as powerful stake holders - as shareholders and lenders they can exercise considerable influence over companies; - as polluters - while not dirty industries, financial institutions do consume natural resources. By the study of these environmental aspects it comes ...

2001-07-01

51

The law aspects of biotechnology patenting. The living source between discovery and invention; Aspetti giuridici del brevetto biotecnologico. La materia vivente tra scoperta e invenzione  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is to provide a comprehensive and consistent description of the complexity of laws regulating the field of biotechnology, mainly focusing on the definition of items to be patented, which is one of the most important and also controversial issues within the new 98/44/EC set of rules. As biotechnology is a specialist and multidisciplinary field, it has begun by giving a general description of the field, outlining the grounds for the new rules, and then thoroughly examined and evaluated previous national and international laws especially with regard to patenting. This was followed by an evaluation of what can be patented according to the new instructions by systematically assessing the section defining items to be patented in the field of biotechnology. It is used to be a matter of opinion whether biotechnological material was to be considered a discovery or an invention, the former being impatentable according to patenting laws. The new law pays particular attention ...

2001-07-01

52

The angiogram sign in pulmonary atelectasis studied with helical Computed Tomography. Incidence and value; Il segno dell'angiogramma nelle atelettasie polmonari studiate con Tomografia Computerizzata spirale. Incidenza e validita' semeiologica  

Energy Technology Data Exchange (ETDEWEB)

In this issue it has been investigated the yield of Helical CT in the study of lung vessels, the incidence of the angiogram sign and its actual value. July 1997 to December 1998, were studied 30 cases of pulmonary collapse of different origin. It was found 15 cases of passive collapse (10 from pleural effusion, 2 from diaphragmatic compression, 2 from traumatic pneumothorax, and 1 from isthmic aortic aneurysm), 12 cases of obstructive collapse (9 from bronchogenic carcinoma, 1 from mucoid obstruction, 1 from ilar lymphadenopathy, and 1 from mediastinal cancer), 2 cases of adhesive collapse and 1 case of round atelectasis. All the examinations were performed with the Helical technique during nonionic iodinated contrast agent injection (bolus, 300-350 mg/mL); it was used an automatic injector set at 2-3 mL/s. It was studied the images for the angiogram sign, that is hyperdense bands, usually longer than 2 cm, through the collapsed lung, which correspond to normal pulmonary vascular ...

1999-12-01

53

Organizational models for new economy in the public and the private one; Modelli organizzativi per la new economy nel pubblico e nel privato  

Energy Technology Data Exchange (ETDEWEB)

Historically the organizational models have followed an evolution that has underlined a parallel trend to the complexity of the market, introducing as different mechanisms of coordination. Up to yesterday the winning model it was that hierarchical that however it is not certainly immune from limits. Beginning from eight hundred and especially in the nine hundred experts of organization have studied an alternative or supplementary model to that hierarchical: the bureaucratic model. This last entrusts the organization of the firm to the norms and the procedures considering them like the best integrating mechanism of development of the organizations. Today it is not made that to speak of the model to net, but it would be a serious error if this had to a substitutive model thought of the precedents, that can work then without hierarchy and without alone procedures entirely thanks to the use of Internet. In the present job are individualized new models of management of the private firms and ...

2001-07-01

54

Helical CT defecography; La defecografia con Tomografia Computerizzata spirale  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus ...

1999-11-01