Well log interpretation of certain geothermal fields in the Imperial Valley, California
Energy Technology Data Exchange (ETDEWEB)
This study reviews the wireline log responses of some geothermal fields in the Imperial Valley, California. The fields under study include the Heber, the East Mesa, the Brawley, and the Westmoreland. The well logs used in the study did not include all the wireline surveys obtained by the operators. The selected well logs obtained under special arrangements with the operators were chosen to maintain the anonymity of specific well locations but are only representative of each area. Analysis of the well logs indicates that on an individual field basis, the well logs are excellent for correlation purposes. The presence of extremely saline fluids in some fields precludes the monitoring of Q/sub v/ (cation exchange capacity per unit volume) profile for detection of hydrothermally altered zones. The producing sections in all the fields are characterized by low porosity and high resistivity.
1984-03-01
Energy Technology Data Exchange (ETDEWEB)
This paper details the development of a decontamination approach for the West Valley Demonstration Project (WVDP), Decontamination Project Plan (Plan). The WVDP is operated by West Valley Nuclear Services Company (WVNSCO), a subsidiary of Westinghouse Government and Environmental Services, and its parent companies Washington Group International and British Nuclear Fuels Limited (BNFL). The WVDP is a waste management effort being conducted by the United States Department of Energy (DOE) at the site of the only commercial nuclear fuel reprocessing facility to have operated in the United States. This facility is part of the Western New York Nuclear Service Center (WNYNSC), which is owned by the New York State Energy Research and Development Authority (NYSERDA). As authorized by Congress in 1980 through the West Valley Demonstration Project Act ...
2002-02-25
Energy Technology Data Exchange (ETDEWEB)
This Remedial Investigation (RI) Work Plan specifically addresses Chestnut Ridge Operable Unit 1, (OU1) which consists of the Chestnut Ridge Security Pits (CRSP). The CRSP are located {approximately}800 ft southeast of the central portion of the Y-12 Plant atop Chestnut Ridge, which is bounded to the northwest by Bear Creek Valley and to the southeast by Bethel Valley. Operated from 1973 to 1988, the CRSP consisted of a series of trenches used for the disposal of classified hazardous and nonhazardous waste materials. Disposal of hazardous waste materials was discontinued in December 1984, while nonhazardous waste disposal ended on November 8, 1988. An RI is being conducted at this site in response to CERCLA regulations. The overall objectives of the RI are to collect data necessary to evaluate the nature and extent of contaminants of concern (COC), support an ecological risk ...
1993-09-01
Energy Technology Data Exchange (ETDEWEB)
Eaton, in partnership with Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) has completed a project that applies a combination of wireless sensor network (WSN) technology, anticipatory theory, and a near-term value proposition based on diagnostics and process uptime to ensure the security and reliability of critical electrical power infrastructure. Representatives of several Eaton business units have been engaged to ensure a viable commercialization plan. Tennessee Valley Authority (TVA), American Electric Power (AEP), PEPCO, and Commonwealth Edison were recruited as partners to confirm and refine the requirements definition from the perspective of the utilities that actually operate the facilities to be protected. Those utilities have cooperated with on-site field tests as the project proceeds. Accomplishments of this project included: (1) the design, modeling, and simulation of the ...
2007-03-31
Combustion performance of Coal Valley coal in a pilot-scale utility boiler. Report No. ERL 87-18(CF)
Energy Technology Data Exchange (ETDEWEB)
Combustion performance trials were conducted on a commercial sample of Coal Valley coal from the Coalspur coalfield in the foothills region of Alberta. The project included an analytical investigation of the coal and coal ash properties as well as combustion studies in the CCRL pilot-scale, pulverized coal-fired boiler, under conditions representative of those in large steam boilers. This report gives the objectives of the project, the analyses of the coals, and describes the facilities and operational procedures. An evaluation of the experimental results and the conclusions are presented.
1987-01-01
Geothermal Energy R&D Program Annual Progress Report for Fiscal Year 1992
Energy Technology Data Exchange (ETDEWEB)
Geothermal budget actual amounts are shown for FY 1989 -1992, broken down by about 15 categories. Here, the main Program categories are: Exploration Technology, Drilling Technology, Reservoir Technology, Conversion Technology (power plants and materials), Industry-Coupled Drilling, Drilling Applications, Reservoir Engineering Applications, Direct Heat, Geopressured Wells Operation, and Hot Dry Rock Research. Here the title--Industry-Coupled Drilling--covered case studies of the Coso, CA, and Dixie Valley, NV, fields, and the Long Valley Exploratory Well (which had started as a magma energy exploration project, but reported here as a hydrothermal prospect evaluation well). (DJE 2005)
1993-07-01
Australia's Latrobe Valley brown coal fields
Energy Technology Data Exchange (ETDEWEB)
Brown coal resources of the Latrobe Valley in Australia total 140 billion tons to a depth of 975 feet, while economically recoverable reserves have been calculated to total 57 billion tons. Although the coal provides only a very low heating value, about 3300 Btu/lb with 60% moisture content, the enormous seam thicknesses with little overburden allow large scale, open cut mining operations. The low cost and high reactivity of the coal is attracting extensive coal liquefaction research. Research into dewatering processes for the high moisture content brown coal is being conducted. The dried brown coal could be used both domestically and internationally for electricity generation and as an industrial fuel.
1984-02-01
Snake River Sockeye Salmon Habitat and Limnological Research; 1995 Annual Report.
Energy Technology Data Exchange (ETDEWEB)
This report contains studies which are part of the Bonneville Power Administration`s program to protect, mitigate, and enhance fish and wildlife affected by the development and operation of hydroelectric facilities on the Columbia River and its tributaries. Attention is focused on population monitoring studies in the Sawtooth Valley Lakes. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.
1996-05-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Four stratigraphic sections in the southern part of the Columbia Basin preserve a sequence of aeolian and non-aeolian sediments ranging in age from 943 to >470 14C ka based on accelerator mass spectrometry radiocarbon dating of fossil molluscs, geochemistry of Cascade Mountain-sourced tephra and association with formally recognized pedostratigraphic units (the Washtucna and Old Maid Coulee soils). Study sections are interpreted as representing concurrent deposition of loess and distal Missoula Flood rhythmites in valleys tributary to main drainages backflooded during the Missoula Floods, and formation of carbonate and iron-rich soils. Sediments belong to the formally recognized L-1 and L-2 loess units established for the Palouse loess, which were deposited in the Columbia Basin su...
2010-01-01
International Nuclear Information System (INIS)
Geologic studies in connection with Project Discus Thrower have furnished detailed stratigraphic and structural information about northwestern Yucca Flat, Nevada Test Site. The Paleozoic rocks consist of a lower carbonate sequence, argillite of the Eleana Formation, and an upper carbonate sequence. The distribution of these rocks suggests that both top and bottom of the Eleana are structural contacts, probably thrusts or reverse faults. The overlying tuff includes several units recognized in the subsurface, such as the Fraction Tuff and tuff of Redrock Valley. Other units recognized include bedded tuff associated with the Grouse Canyon Member of Belted Range Tuff, and the Rainier Mesa and Ammonia Tanks Members of the Timber Mountain Tuff. The Timber Mountain and Grouse Canyon are extensively altered to montmorillonite (a swelling clay), possibly as a result of ponding of alkaline water. The overlying alluvium locally ...
Tensors, spinors, and functions on the unit sphere
International Nuclear Information System (INIS)
A representation of tensors and spinors at a point of space-time as spin and conformally weighted functions on the unit sphere is derived. Methods for performing algebraic operations on tensors and spinors in this representation are discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
The purposed project is a commercial-scale ethanol-fuel facility with a capacity of twenty million gallons per year of fuel-grade ethanol. In addition, 70,000 tons per year of distillers dried grains will be produced. The following tasks and issues are addressed: process engineering - process descriptions, plant layout, and design; economics and finance - overview of capital and operating costs; environmental analysis - preliminary project description; and permit processing and legal issues. (MHR)
1981-08-01
Waste generation and pollution prevention progress fact sheet: West Valley Demonstration Project
Energy Technology Data Exchange (ETDEWEB)
This Fact Sheet presents the mission of the West Valley Demonstration Project and information on the 1994 pollution prevention and recycling accomplishments.
1994-12-31
UK PubMed Central (United Kingdom)
ObjectiveTo investigate possible differences in operative delivery rate among low-risk women, randomised to an alongside midwifery-led unit or to standard obstetric units within...Full Text Available
2011-10-01
Guidance on quality assurance requirements during the operations phase of nuclear power plants
International Nuclear Information System (INIS)
26 Oct 1973. 140 p. United States USAEC, Washington, DC
Interim remedial measures proposed plan for the 200-ZP-1 Operable Unit, Hanford Site, Washington
Energy Technology Data Exchange (ETDEWEB)
The purpose of this interim remedial measures (IRM) proposed plan is to present and solicit public comments on the IRM planned for the 200-ZP-1 Operable Unit at the Hanford Site in Washington state. The 200-ZP-1 is one of two operable units that envelop the groundwater beneath the 200 West Area of the Hanford Site.
1993-12-01
Ion exchange at TNX using the SKID unit
Energy Technology Data Exchange (ETDEWEB)
An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination factor (DF) will be ...
1993-10-21
Energy Technology Data Exchange (ETDEWEB)
Within the EU-Project VOTALP (Vertical Ozone Transports in the Alps), we have shown that deep alpine valleys like the Mesolcina Valley very efficiently transport air out of the polluted valley up to altitudes between 2000 and near 4000 m asl (above sea level). Pollutants emitted in these valleys are very efficiently transported up to high altitudes. (author) 2 figs., 1 tab., 2 refs.
1999-08-01
Conversion of selected military forces to the use of metric measurement units
Conversion of the United States military to the International System of measurement units is in the very early stages. Little formal planning has been done to articulate the management required to complete the conversion of operational Army and Air Force units. For those operational forces tasked to provide continuous combat readiness throughout metrication, management problems associated with the conversion are particularly difficult because of the nature of these assigned missions. This is the case for the 82nd Airborne Division ready brigade force (DRB) and the Military Airlift Command (MAC) strategic airlift system operating the C-141 and C-5A aircraft.
1976-06-01
Procedure for operating reactors
International Nuclear Information System (INIS)
The invention concerns a procedure for operating reactors in nuclear power plants. It aims at utilizing power reserves in nuclear power plants. This can be achieved by a steam-side connection of the steam generators of two reactors. The amount of steam exchanged between the units is chosen in such a way that power changes at the steam turbines feedback mainly to the corresponding reactor. In order to realize a high power transfer it is necessary to return the amount of condensate produced in the steam receiving unit and corresponding to the power transferred to the feedwater system of the steam donating unit.
1985-11-11
Planning and Operational Considerations for Units Utilizing Military Workingn> Dogs.
Military working dogs are rapidly becoming integral to military operations. While they bring many valuable capabilities to the battlefield, it is important that Special Operations leaders consider canine team capabilities and requirements when planning mi...
2009-01-01
Survey of Flue Gas Desulfurization Systems: Bruce Mansfield Station, Pennsylvania Power Co.
This report gives the results of a survey of operational flue gas desulfurization (FGD) systems on coal-fired utility boilers in the United States. The FGD systems installed on Units 1 and 2 at the Bruce Mansfield Station of the Pennsylvania Power Company...
1979-01-01
Status and progress in sludge washing: A pivotal pretreatment method
Energy Technology Data Exchange (ETDEWEB)
Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations involve batchwise mixing, settling, and ...
1995-01-01
High-level waste canister storage final design, installation, and testing. Topical report
Energy Technology Data Exchange (ETDEWEB)
This report is a description of the West Valley Demonstration Project`s radioactive waste storage facility, the Chemical Process Cell (CPC). This facility is currently being used to temporarily store vitrified waste in stainless steel canisters. These canisters are stacked two-high in a seismically designed rack system within the cell. Approximately 300 canisters will be produced during the Project`s vitrification campaign which began in June 1996. Following the completion of waste vitrification and solidification, these canisters will be transferred via rail or truck to a federal repository (when available) for permanent storage. All operations in the CPC are conducted remotely using various handling systems and equipment. Areas adjacent to or surrounding the cell provide capabilities for viewing, ventilation, and equipment/component access.
1998-04-01
Forced convective heat transfer in cross-corrugated solar air heaters
Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local heat transfer rates on the two locations was related to the Reynolds number.
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
Lateral plume dispersion in deep river valleys during neutral and stable lapse rate conditions can be exceptionally high due to the intense horizontal turbulence generated by prominent variations in the width, orientation and surface roughness of the valley walls. Use of the standard Gaussian dispersion equation to represent this enhanced lateral plume spread in a narrow valley may be inappropriate since consideration should also be given to the restriction of the horizontal plume spread due to impingement against the valley walls. The basic concept employed in the modification of the Gaussian dispersion equation was to assume that multiple eddy reflections occur between the valley walls in a manner similar to the vertical eddy reflections between the ground plane and an inversion layer aloft. The expressions are developed, but no attempt has been made to validate them with actual ...
1986-02-01
Evaluating and improving the operating reliability of the units of sucker rod well pumps
Energy Technology Data Exchange (ETDEWEB)
The theory of reliability is used to develop statistical field data on malfunctions of units of sucker rod well pumps (UShSN). The indices of reliability of the UShSN are applied for establishment of the cause-effect links between the operating factors. Dependences of operating time on the depth of suspension of the pumps, mode of pumping out, degree of flooding of the oil, and twisting of the shafts are established for conditions of specific fields. The obtained relationships can be used in selecting and optimizing the work of the UShSN.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
A summary of the 1983 Critical Solvent Deashing unit performance at the Wilsonville Advanced Coal Liquefaction R and D Facility is presented. All periods of on feed operation, unscheduled shutdowns, and scheduled shutdowns are accounted for and tabulated. Causes of unscheduled shutdowns are identified and discussed. Details of repeated, major maintenance problems with various pieces of equipment are presented. Where applicable, solutions are discussed. Historical operations and maintenance data are presented and used for comparison purposes in order to better indicate areas of improvement in the unit. 4 references, 7 figures, 3 tables.
1985-03-01
The Stryker Brigade Combat Team. Rethinking Strategic ...
... For short-warning crises in other regions, Marine Expeditionary Units, the 82nd Airborne Division, Special Operations Forces, and Air Force/Navy ...
Multi-Robot Operator Control Unit
... see http://www.spawar.navy.mil/robots/ ), during which ... pixel-accurate routes for a small ground robot using aerial ... a USV, a UAV and a UUV as well ...
2006-04-01
Environmental Impact Analysis Process. Final Environmental ...
... Abstract : The United States Air Force (USAF) currently operates the Milstar satellite system to provide Military Satellite Communication Systems ...
2001-02-15
Eight units (low-power model Z-12's) were purchased, all for installation at continuously- operating stations in the Los Angeles prototype Dense GPS ...
Energy Technology Data Exchange (ETDEWEB)
Lacustrine rocks are a significant component of many rift-valley sequences. Comparisons of both active and ancient rift valleys indicate that the lacustrine facies are commonly rich in organic matter and may be important sources for oil. For example, Holocene sediments in Lake Tanganyika and Cretaceous lacustrine rocks in west Africa contain as much as 12% and 20% TOC, respectively. The Newark Supergroup contains abundant lacustrine rocks. The widespread occurrence of black shales, the general similarity to known organically rich rift systems, and a few isolated geochemical analyses have caused some speculation about the potential of the Newark Supergroup to be an effective source of oil and gas. Sufficient geochemical analyses are available from lacustrine rocks in the Newark, Connecticut, and Deep River basins to evaluate their potential as hydrocarbon sources. In general, both the quantity and quality of organic matter in these rocks are ...
1985-02-01
A duplex real-time RT-PCR assay for the detection of California serogroup and Cache Valley viruses
UK PubMed Central (United Kingdom)
A duplex TaqMan real-time RT-PCR assay was developed for the detection of California (CAL) serogroup viruses and Cache Valley virus (CVV), for use in human surveillance. The targets selected...Full Text Available
2009-10-01
A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal...
Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...
2011-08-20
Cyber as a 'Team Sport': Operationalizing a Whole-Of-Government Approach to Cyberspace Operations.
Cyberspace and its associated operations present both opportunities and challenges for military and United States Government decision-makers and planners. The Pentagon has formally recognized cyberspace as a domain of warfare. Cyberspace is man-made, dyna...
2011-01-01
Core technologies for Tritium removal processes (I).
In case of operating both Wolsung Nuclear Units 1 and 2 without operating tritium removal facilities, it is estimated that tritium in 2013 would be accumulated up to about 30 million Ci that would result in about 2,300 man-rem of tritium exposure to opera...
1992-01-01
Display concepts for maintaining alarm state overview during unit evolutions
Energy Technology Data Exchange (ETDEWEB)
Control room operators rely on the plant annunciation system to alert them to abnormal operating conditions and changes in plant configuration. A key determinant in annunciation system effectiveness is how well the annunciation system displays support Operations staff to staff to maintain a full understanding of the alarm state and ongoing changes under all operating situations. During unit evolutions, current CANDU alarm generation rates can frequently exceed 10 alarms per minute. With existing annunciation displays that list individual alarm changes, the rapid changes in display presentation can exceed an operator's ability to recognize the changes and maintain a full and up-to-date awareness of unit alarm state. This paper describes annunciation display features and concepts for alternative presentation of ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
This document contains the accident sequence analysis of internally initiated events for Grand Gulf, Unit 1 as it operates in the Low Power and Shutdown Plant Operational State 5 during a refueling outage. The report documents the methodology used during the analysis, describes the results from the application of the methodology, and compares the results with the results from two full power analyses performed on Grand Gulf.
1994-06-01
Recovery and reuse of spent acetone via a mobile solvent recovery unit
Energy Technology Data Exchange (ETDEWEB)
The Monsanto Chemical Company operates a plastics and resins plant located in Addyston, Ohio. The process equipment requires routine rinsing with technical grade acetone between batches. Due to the volumes of spent acetone generated and the associated RCRA hazardous waste regulations, the plant sought to recycle and reuse the acetone to reduce the purchase cost of virgin acetone and the cost of spent acetone disposal. One of the first options explored was package unit distillation units. The cost of these units was in the $20--$30,000 range in 1989 dollars. Even though the cost of a package unit was not deemed unreasonable, there were additional costs and concerns that led to elimination of this option. The unit would have required additional manpower to operate and maintain, i.e., at least a fraction of an operator and ...
1996-11-01
Planning and operational considerations for units utilizing military workingn> dogs.
Military working dogs are rapidly becoming integral to military operations. While they bring many valuable capabilities to the battlefield, it is important that Special Operations leaders consider canine team capabilities and requirements when planning missions. Careful logistical and operational planning can optimize the health, performance, and readiness of the working dog while protecting the safety and well-being of the team members working with them. We also offer recommendations for medical treatment of dog bites. PMID:19813342
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
This Waste Management Plant (WMP) for the Bear Creek Valley Treatability Study addresses waste management requirements for the Oak Ridge Y-12 Plant. The study is intended to produce treatment performance data required to design a treatment system for contaminated groundwater. The treatability study will consist of an evaluation of various treatment media including: continuous column tests, with up to six columns being employed to evaluate the performance of different media in the treatment of groundwater; an evaluation of the denitrifying capacity and metal uptake capacity of a wetland system; and the long-term denitrifying capacity and metal uptake capacity of algal mats. The Sampling and Analysis Plan (SAP) covers the project description, technical objectives, procedures, and planned work activities in greater detail. The Health and Safety Plan (HASP) addresses the health and safety concerns and requirements for the proposed sampling activities. This WMP ...
1997-05-01
Eielson Air Force Base Operable Unit 2 baseline risk assessment
Energy Technology Data Exchange (ETDEWEB)
Operable Unit 2 at Eielson Air Force Base (AFB) near Fairbanks, is one of several operable units characterized by petroleum, oil, and lubricant contamination, and by the presence of organic products floating at the water table, as a result of Air Force operations since the 1940s. The base is approximately 19,270 acres in size, and comprises the areas for military operations and a residential neighborhood for military dependents. Within Operable Unit 2, there are seven source areas. These source areas were grouped together primarily because of the contaminants released and hence are not necessarily in geographical proximity. Source area ST10 includes a surface water body (Hardfill Lake) next to a fuel spill area. The primary constituents of concern for human health include benzene, toluene, ethylbenzene, and xylenes ...
1994-10-01
Power system stabilizer application in a two unit plant analytical studies and field tests
Energy Technology Data Exchange (ETDEWEB)
The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the alternator rectifier type and the PSS control utilizes shaft speed as an input signal. ...
1983-02-01
Integrity assessment of pressure tubes for Wolsung unit 2
Energy Technology Data Exchange (ETDEWEB)
To improve operational safety of the fuel channel for Wolsung units the recommended primary heat transport system (PHTS) operating guidelines were developed, which provides a safe operation window in terms of pressure and temperature to maintain fuel channel integrity, which is similar to pressure-temperature curves used for primary pressure boundary integrity in PWRs and deterministic Leak-Before Break (LBB) analyses were conducted using recent understanding of delayed hydride cracking (DHC) mechanism. In addition, a comparative assessment of LBB analysis was made using the procedures of Fitness For Service Guidelines(FFSG) for pressure tubes rev. 0 and rev. 1.
1997-10-01
The Rio Grande alluvial floodplain aquifer between El Paso/Juarez and Fort Quitman, Texas has been intensively tilled and irrigated since 1910. Almost since that time, the Rio Grande and its interconnected alluvial aquifer in this stream reach have been affected by excessive salinity problems. Presently, salinity of surface water and groundwater increases from 800 to 2000 mg/L total dissolved solids (TDS) near El Paso, Texas to 2500 to 5500 mg/L TDS near Fort Quitman, Texas, approximately 115 km downstream. Chloride (Cl) and Chloride/Bromide (Cl/Br) ratios increase downstream, with a marked increase in salinity beginning about 45 km below El Paso. Groundwater sampling in an intensively investigated reach of the floodplain aquifer, extending from 35 to 60 km below El Paso identified two distinct water types. The first water type (17 samples) is a relatively dilute groundwater containing 1000 to 2000 mg/L TDS, 250 to 600 mg/L Cl, and Cl/Br weight ratios of 550 to 900. The second ...
2005-12-01
cost-benefit analysis of legumes irradiation processing in egypt
International Nuclear Information System (INIS)
This paper discusses the economics of legumes irradiation such as Chickpea,Lupin,Kidny Bean and broad and the effect of various parameters on unit processing costs. It provides a model for calculating specific unit processing costs by correlating known capital costs with annual operation cost an annual throughputs. We analysed the cost-benefit of the proposed grain irradiation facility. We took into account the cost of the capital investment, operation and other additional parameters and then estimated the unit processing cost. The investment criteria utilized for commercial evaluation were internal rate of return (I.I.R), pay back period (P.B.P), and average rate of return (A.R.R). The irradiation cost and the additional income are also discussed. The results of this analysis showed that the installation of an irradiation unit for legumes processing in Egypt ...
2004-01-01
Energy Technology Data Exchange (ETDEWEB)
The main benefit of electric cars is to reduce air pollution in cities that is thus desirable to equip them with non polluting air conditioning units and this rules out frigorific compressors operating with CFC. The planned replacement of CFC by HFC is at best an interim solution. The best solution is certainly to use thermoelectric air conditioning units, which are inherently pollution-free. However, these have a fairly low COPF when compared to traditional compressor units. We study the relationship between the cooling of the interior of urban electric cars and the merit factor of the thermoelectric material in their Peltier unit. This should help provide concrete target properties of future T E materials. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.
1994-08-10
Diesel-fueled solid oxide fuel cell auxiliary power units for heavy-duty vehicles
Energy Technology Data Exchange (ETDEWEB)
This paper explores the potential of solid oxide fuel cells (SOFCS) as 3--10 kW auxiliary power units for trucks and military vehicles operating on diesel fuel. It discusses the requirements and specifications for such units, and the advantages, challenges, and development issues for SOFCS used in this application. Based on system design and analysis, such systems should achieve efficiencies approaching 40% (lower heating value), with a relatively simple system configuration. The major components of such a system are the fuel cell stack, a catalytic autothermal reformer, and a spent gas burner/air preheater. Building an SOFC-based auxiliary power unit is not straightforward, however, and the tasks needed to develop a 3--10 kW brassboard demonstration unit are outlined.
2000-05-15
ICDF Complex Operations Waste Management Plan
This Waste Management Plan functions as a management and planning tool for managing waste streams generated as a result of operations at the Idaho CERCLA Disposal Facility (ICDF) Complex. The waste management activities described in this plan support the selected remedy presented in the Waste Area Group 3, Operable Unit 3-13 Final Record of Decision for the operation of the Idaho CERCLA Disposal Facility Complex. This plan identifies the types of waste that are anticipated during operations at the Idaho CERCLA Disposal Facility Complex. In addition, this plan presents management strategies and disposition for these anticipated waste streams.
2006-12-01
Techno-economic assessment of anaerobic digestion systems for agri-food wastes
Energy Technology Data Exchange (ETDEWEB)
Activities in British Columbia's Fraser Valley generate an estimated 3 million tones of agriculture and food wastes annually, of which 85 per cent are readily available for anaerobic digestion. The potential for energy generation from biogas through anaerobic digestion is approximately 30 MW. On-farm manure-based systems represent the most likely scenario for the development of anaerobic digestion in British Columbia in the near future. Off-farm food processing wastes may be an alternative option to large centralized industrial complexes. Odour control, pathogen reduction, improved water quality, reduced greenhouse gas emissions and reduced landfill usage are among the environmental benefits of anaerobic digestion. The economical benefits include power and heat generation, biogas upgrading, and further processing of the residues to produce compost or animal bedding. This paper described a newly developed anaerobic digestion (AD) calculator that helps users ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the test) in the calculation of corrosion rate, and is referred to as ...
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). Since subsurface temperature and surface heat flow data exhibit major deviations from the axisymmetric approximation, exploratory three-dimensional calculations are ...
1982-01-01
Comparison of digital and analogue data acquisition systems for nuclear spectroscopy
International Nuclear Information System (INIS)
In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient #alpha#-particle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly #alpha#-active actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong #alpha#-emitter, when applying the #alpha#-particle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded ...
2010-12-21
Method for processing statistical information concerning sucker-rod pump unit operations
Energy Technology Data Exchange (ETDEWEB)
The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.
1982-01-01
International Nuclear Information System (INIS)
Specifications of the PGV-1000 steam generators applied at the WWER-1000 NPP power units, operational experience and data on damages at the 'cold' heat carriers of steam generators are considered and their results are presented. Developed and introduced measures aimed at improving reliability and operational life of the PGV-1000 collectors are described.
1993-01-01
British Library Electronic Table of Contents (United Kingdom)
Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
2011-01-01
Binary heat pump system. Binary heat pump system
Energy Technology Data Exchange (ETDEWEB)
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This system is characterized by the simultaneous operation of cooling and heating, high ...
1993-11-30
Optimizing power plant cycling operations while reducing generating plant damage and costs
Energy Technology Data Exchange (ETDEWEB)
This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro power plant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil power plants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The information in this Final Environmental Statement is the second assessment of the environmental impacts associated with the construction and operation of the Grand Gulf Nuclear Station, Units 1 and 2, located on the Mississippi River in Claiborne County, Mississippi. The Draft Environmental Statement was issued in May 1981. The first assessment was the Final Environmental Statement related to construction, which was issued in August 1973 prior to issuance of the Grand Gulf Nuclear Station construction permits. In September 1981 Grand Gulf Unit 1 was 92% complete and Unit 2 was 22% complete. Fuel loading for Unit 1 is scheduled for December 1981. The present assessment is the result of the NRC staff review of the activities associated with the proposed operation of the Station, and includes the staff responses to comments on the Draft Environmental Statement.
1981-09-01
International Nuclear Information System (INIS)
The CAMDU 6 reactor has an international reputation as one of the world's best performing and safe reactors. CANDU 6 reactors are consistently ranked in the world's top 10 for annual and lifetime performance. Six CANDU 6 units are currently in operation in four continents; in Quebec, New Brunswick, South Korea, Argentina and Romania. There are another two CANDU 6 units currently under construction at wolsong, in Korea which ore scheduled to go into service in 1998 and 1999 respectively. A second CANDU 6 unit is currently being considered for Romania. The construction of two CANDU 6 units at Qinshan, in China, is now underway. The performance of the four first-generation CANDU 6 plants, which have now been in service for 15 years, continue to show very good performance, with capacity factors on average since in-service of over 85%. The annual capacity factor of 10.21% during 1997 has ...
1998-03-23
Energy Technology Data Exchange (ETDEWEB)
A chronology for Paleocene strata of the Hinton area of west-central Alberta was developed from the integration of a magnetostratigraphic and palynostratigraphic study of the upper Coalspur and middle to upper Paskapoo strata in the Coal Valley to Obed Mountain area. The study resulted in the compilation of a complete section of 1100 m of strata with a maximum sediment accumulation rate of 250 m/m.y. Four new informal biostratigraphic units were used to highlight stratigraphically useful bioevents not previously recognized in existing zonations. These strata range in age from magnetochron 29r to 24r and palynozones Wodehouseia spinata Zone, Aquilapollenites reticulatus Subzone through the Pistillipollenite mcgregorii Zone. The 3 intervals with the most rapid changes in the palynoflora were the earliest Paleocene; the transition from the early to middle Paleocene; and in the late Paleocene. Each coincides with critical times in basin ...
2008-06-15
An abundance of waste corn, a key food of many wildlife species, has helped make possible the widespread success of wildlife management in the United States over the past half century. We found waste corn post harvest in Nebraska declined by 47% from 1978 to 1998 due primarily to improvements in combine headers resulting in a marked decline in ear loss. The reduction in waste coincided with major declines in fat storage by sandhill cranes and white-fronted geese during spring migration. Sandhill cranes, northern pintails, white-fronted geese, and lesser snow geese avoided soybeans while staging in spring in the Rainwater Basin Area and Central Platte River Valley. These findings and other literature suggest soybeans are a marginal food for wildlife particularly during periods of high energy requirements. Soybean acreage has increased by 600% in the United States since 1950 and now comprises nearly one-quarter of the ...
2004-01-01
Accommodation controls on fluvial-deltaic reservoir architecture
Energy Technology Data Exchange (ETDEWEB)
Hydrocarbon recovery efficiency is controlled by reservoir heterogeneities resulting from geometric arrangements of strata, or {open_quotes}stratal architecture{close_quotes}. Traditional reservoir characterization relates depositional systems to stratal architecture. High-resolution sequence stratigraphy of outcrop analogs provides a chronostratigraphic framework for evaluating accommodation conditions of depositional systems. Key stratigraphic surfaces and/or correlative strata define a hierarchy of chronostratigraphic units of different periodicities. The Upper Cretaceous Ferron Sandstone, an analog to high accommodation and sediment supply fluvial-deltaic reservoirs, comprises an intermediate-term stratigraphic sequence consisting of seven short-term stratigraphic cycles. Each short-term stratigraphic cycle contains fluvial- to storm-dominated shallow-marine deposits laterally replaced by distributary channel deposits. The Lower Cretaceous Fall River Formation, ...
1995-08-01
Reconsidering the site requirements for NPP on Olt River
International Nuclear Information System (INIS)
Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling circuit system was applied for PWR NPP type ...
2009-10-12
Proceedings of the Areva Technical Days. Session 5
Energy Technology Data Exchange (ETDEWEB)
This document presents the proceedings of the Areva technical days, presented during the session 5 the 9 and 10 december 2004, at Istanbul. It deals with the operations of the transmission and distribution division. With manufacturing facilities in over 40 countries and a sales network in over 100, Areva offers customers technological solutions for nuclear power generation and electricity transmission and distribution (the Group also provides interconnect systems to the telecommunications, computer and automotive markets). It provides five topics: a general presentation of Areva, the strategic stakes for transmission and distribution by world-zone, economic and strategic stakes of business unit products, business unit systems and business unit automation. (A.L.B.)
2004-07-01
Fireplaces and Fireplace Fuels.
This instructional unit is one of 10 developed by students on various energy-related areas that deals specifically with fireplaces and fuels. Its objective is for the student to be able to discuss the structural design, operation, and efficiency of fireplaces and characteristics of different fireplace fuels. Some topics covered are fuels, elements of the fire triangle, factors relating to high efficiency of masonry fireplaces, uses of grates and chimney, heat recovery, and prefabricated and free standing fireplaces. Materials in each unit may include some or all of the following: terminal and specific objectives, list of references, information sheet with terms and definitions, informative materials, transparency masters, assignment sheet(s), and unit test with answers. (YLB)
1981-06-01
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
The purpose of the project is to further develop a Danish natural gas reformer system including optimisation of subsystems and the overall system consisting of a natural gas reformer and fuel cell CHP generator. This will contribute to the evaluation of to what extend Denmark shall develop small reformer units for PEM fuel Cells. In the project a reformer system with a high degree of automatic control has been build that fulfils the CHP requirements to operation time, dynamics etc. This work, with a FP05 reformer unit, has given valuable results concerning the possibilities and limitations of the reformer technology for CHP usage. It is important that the reformer and fuel cell units are designed with matching yields to optimise efficiency, turn-down start-up time etc. The burner that delivers heat for the steam reaction shall be able to use natural gas as fuel. This gives the possibility of using ...
2006-11-03
Device for advancing the base of a stoping unit
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.
1980-12-13
Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...
1996-01-01
International Nuclear Information System (INIS)
... 978-5-94883-072-8 121 p. SPECIFIC NUCLEAR REACTORS AND
UK PubMed Central (United Kingdom)
An outbreak with a multiresistant Klebsiella pneumoniae (MRKP) strain among seven patients admitted to the adult intensive care unit (ICU) of a regional teaching hospital in The Netherlands...Full Text Available
2005-10-01
Mercury vacuum cleaner operational test and evaluation
Energy Technology Data Exchange (ETDEWEB)
The Dental Investigation Service, USAFSAM, Brooks AFB, has outlined the need for a vacuum unit to be used in the Air Force dental clinics. The unit must be capable of effectively picking up mercury and at the same time not redistribute mercury vapors throughout the dental clinic during normal operations or mercury-spill situations. The Dental Investigation Service selected the MRS-3, Minuteman Mercury Recovery System, product of American Cleaning Equipment Corporation as the mercury vacuum to be used for T E. The USAF OEHL/ECH was requested by the Dental Investigation Service to perform the T E on the MRS-3 for possible health hazards due to exposures of mercury vapors.
1981-03-01
Establishment of PHWR limiting condition for operation
International Nuclear Information System (INIS)
Current technical specifications of Wolsong Unit 2,3,4 was analyzed and improvement methods was suggested to develop Improved Standard Technical Specifications(ISTS) of PHWR. The selection criteria of PHWR limiting condition for operation(LCO) was established, then limiting conditions for operationl were selected. The number of current LCOs for Wolsong Units 2,3,4 is 109, and 46 LCOs(42%) were relocated by the selection criteria of PHWR LCO. 63 LCOs which met the selection criteria of PHWR LCO were recomposed to 59 LCOs.
2003-05-29
Dynamic stabilizer on-line experience
Energy Technology Data Exchange (ETDEWEB)
A brief description is presented of the Westinghouse Torsional Dynamic Stabilizer, which was developed primarily as a countermeasure to ''torsional interaction'' subsynchronous resonance. Two such systems were installed and commissioned at the San Juan Generating Station, Waterflow, New Mexico in July, 1980. This paper describes the maintenance procedures and operating experience to date of these two units. The only known instance of operation at the high level bias point of the Stabilizer appears to indicate that the unit helped to dampen a turbine-generator shaft oscillation transient.
1984-01-01
The first quarter 1982 report summarizes the operating and test data obtained at the six ton per day Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. The Wilsonville R and D Facility was in operation 52% of the period with scheduled shutdowns accounting for 33% of the downtime. Illinois 6 coal from the Burning Star No. 2 mine was processed during Run 236. The three process units of the Wilsonville facility were operated in a non-integrated mode to evaluate process parameters and to test equipment and operating modifications. Data were obtained in the following areas: In the SRC Unit: operation at low severity reaction conditions for single stage liquefaction with a high LSRC recycle rate using Illinois 6 coal; process solvent activity control; and preliminary feeding tests with hydrotreated SRC as a ...
1983-04-01
Operation of the Wilsonville Advanced Coal Liquefaction R and D Facility, 1981. Annual report
This report summarizes the 1981 operating and test data obtained at the six ton per day Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. Special emphasis is placed on data accumulated during the fourth quarter of 1981. The Wilsonville R and D Facility was in operation 71% of 1981 (70% of the fourth quarter) with scheduled shutdowns accounting for 23% of the downtime (28% during the fourth quarter). Kentucky 9 coal from the Fies mine was processed in all runs conducted during 1981 (Runs 222 through 235). The hydrotreater (HTR) unit was brought on stream successfully in May 1981. The three process units of the Wilsonville facility were operated in a non-integrated mode during the second half of 1981. Significant data was obtained and is summarized.
1984-08-01
The Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama
Energy Technology Data Exchange (ETDEWEB)
This report presents the operating results for Run 255 at the Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. This run operated in the Close Coupled Integrated Two-Stage Liquefaction mode (CC-ITSL) using Martin Lake Texas lignite. The purpose of this run was to demonstrate unit and system operability with Martin Lake lignite. Run 255 began on 20 March 1988 and continued through 9 June 1988. During this period, 204.4 MF tons of Martin Lake Texas lignite were fed in 1865.5 hours of operation. 70 figs., 21 tabs.
1991-05-01
Energy Technology Data Exchange (ETDEWEB)
This report illustrates how, thanks to the development of a new algorithm for the probabilistic evaluation in a given period (e.g. one week) of the operating costs and risk indices (reliability) of a generation system with energy-constrained units, it has been possible to significantly improve the WAT program, used for many years by ENEL for generation expansion planning studies. In particular, it describes how the annual simulation of the system operation is accomplished, so as to calculate the mean expected values of the yearly operating costs (fuel) and the risk indices, at the same time optimizing the use of hydro resources and pumped-storage plants. (author).
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.
2006-07-01
International Nuclear Information System (INIS)
Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.
2006-11-02
The kWh model finds the kWh outputs of each plant and reservoir capacities of hydro and pumped storage plants and minimizes the sum of fixed charges for constructing the reservoirs and generating facilities, also the fuel costs of thermal and nuclear plants. It is a linear programming problem whose constants are represented by nonlinear functions of kW running capacity of each plant. The optimal pattern of nuclear and thermal units is found by solving the linear programming problem derived for the pumped storage and hydroplants. Excluding the upper bound constraints, the number of constraint equations are few and do not increase with the number of units, although the number of variables increases. The computing time increases only in proportion to the number of groupings of generating units. Sensitivity analysis can be done easily. The detailed operational behavior of each generating ...
1979-03-01
Foundation of a drill unit for cluster drilling of wells
Energy Technology Data Exchange (ETDEWEB)
The foundation of a drill unit for cluster drilling of wells is proposed, which includes support, intermediate, and primary girders, forward and rear carts attached to them, railways and traction units. In order to improve operating reliability of the device during unloading on the cart during drilling and placement of the elevator and movement of the foundation within the area of the cluster of boreholes, it is equipped with controllable rods for connecting the carts to one another with the power component. Each of the power components is attached by hinges to a cart and intermediate girder, while the railways with parts are located on supporting girders. The forward carts are connected to the traction units. In order to reduce labor in moving the foundation to a new borehole of the cluster the foundation has brackets and temporary support. The power components have braces which are connected by hinges ...
1980-03-15
Technical Standards for Wolsong Unit 1 Nuclear Power Plant
International Nuclear Information System (INIS)
More than twenty years after commencing commercial operation in 1983, Wolsong Unit 1(W1- NPP), the first CANDU Pressurized Heavy Water Reactor (PHWR) in Korea, has been undergoing refurbishment. Safety analyses were required to evaluate the safety of W1-NPP because significant amount of equipment has been refurbished. To evaluate the effectiveness of W1-NPP after these upgrades, new safety analyses were performed using the same technical standards of Wolsong Units 2, 3, 4 (W234-NPP) for Design Basis Accidents (DBA). The refurbished W1- NPP is expected to be licensed for full power operation based on the verified safety analysis results that are obtained by using the upgraded computer codes and newly adopted technical standards of W234-NPP
2010-10-01
British Library Electronic Table of Contents (United Kingdom)
In this paper, the performance of customer-owned distributed generation (DG) units is quantified from different perspectives through an uncertainty study. A Monte Carlo-based method is applied to assess the stochastic operation of the customer-owned DG units in the power distribution system. Several cases are studied to analyze the impact on system performance of using such generators, with the emphasis on benefits. The results of the studied cases show that proper operation of customer-owned DG units placed close to significant consumption centers offers several benefits which lead to significant energy savings and improvement in the performance indices while maintaining the cost-effectiveness. Furthermore, based on the energy demand, different electricity price scenarios considering a co...
2011-01-01
1988 EEI (Edison Electric Institute) power directory
Energy Technology Data Exchange (ETDEWEB)
Generated annually from the Edison Electric Institute's POWER STATISTICS Data Base, the EEI Power Directory provides state-by-state data on all utility-owned steam-electric plants in the US. The 1988 directory contains the following information for approximately 2500 units located at 1000 generating sites around the country: unit age, capacity, fuel type, and operating status. In addition, solid waste disposal methods for fly ash, bottom ash, and sludge are covered for approximately 1500 US coal-fired units. The directory contains a listing of more than 800 environmental managers and key environmental staff at over 300 utilities, with names, addresses, and telephone numbers. Special indices list plants and utility owner-operators.
1988-05-01
Energy Technology Data Exchange (ETDEWEB)
Rotary screw traps, located at four sites in the Grande Ronde River basin, were used to characterize aspects of early life history exhibited by juvenile Onchorhychus mykiss during migration years 1995-99. The Lostine, Catherine Creek and upper Grande Ronde traps captured fish as they migrated out of spawning areas into valley rearing habitats. The Grande Ronde Valley trap captured fish as they left valley habitats downstream of Catherine Creek and upper Grande Ronde River rearing habitats. Dispersal downstream of spawning areas was most evident in fall and spring, but movement occurred during all seasons that the traps were fished. Seaward migration occurred primarily in spring when O. mykiss smolts left overwintering area located in both spawning area and valley habitats. Migration patterns exhibited by O. mykiss suggest that Grande Ronde Valley habitats are used for overwintering ...
2001-07-01
Survey on Aging Deterioration of Safety Related Equipment in Operating Nuclear Power Plants
International Nuclear Information System (INIS)
As a basic research to consider aging deterioration of the operating nuclear power plant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructive tests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective ...
1997-04-14
Survey on Aging Deterioration of Safety Related Equipment in Operating Nuclear Power Plants
Energy Technology Data Exchange (ETDEWEB)
As a basic research to consider aging deterioration of the operating nuclear power plant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructive tests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective ...
2008-02-15
Design modifications in 540 MWe and its impact on the dose rates
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated ...
2005-11-23
B Plant treatment, storage, and disposal (TSD) units inspection plan
Energy Technology Data Exchange (ETDEWEB)
This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under ...
1996-04-26
The Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama
The investigation of various Two-Stage Liquefaction (TSL) process configurations was conducted at the Wilsonville Advanced Coal Liquefaction R D Facility between July 1982 and September 1986. The facility combines three process units. There are the liquefaction unit, either thermal (TLU) or catalytic, for the dissolution of coal, the Critical Solvent Deashing unit (CSD) for the separation of ash and undissolved coal, and a catalytic hydrogenation unit (HTR) for product upgrading and recycle process solvent replenishment. The various TSL process configurations were created by changing the process sequence of these three units and by recycling hydrotreated solvents between the units. This report presents a description of the TSL configurations investigated and an analysis of the operating and performance data from the period of study. Illinois ...
1990-05-01
Hanford facility dangerous waste permit application, general information portion
Energy Technology Data Exchange (ETDEWEB)
The `Hanford Facility Dangerous Waste Permit Application` is considered to be a single application organized into a General Information Portion (this document, DOE/RL-91-28) and a Unit- Specific Portion. The scope of the General Information Portion includes information that could be used to discuss operating units, units undergoing closure, or units being dispositioned through other options. Documentation included in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units. A checklist indicating where information is contained in the General Information Portion, in relation to the Washington State Department of Ecology guidance documentation, is located in the Contents Section. The intent of the General Information Portion is: (1) to provide an overview of the Hanford Facility; and (2) to assist ...
1996-07-29
Some lessons learned from the DOE site operator program
Energy Technology Data Exchange (ETDEWEB)
Performance of electric vehicles (EVs) is being studied in an ongoing Site Operator Program, as part of the Electric and Hybrid Vehicle Program supported by the U.S. Department of Energy (DOE). More than 200 EVs are being operated by Site Operators in various geographical and climatic regions of the United States. Cold-weather operation of EVs is of particular interest. As expected, low temperatures affect a battery`s ability to accept a charge, which decreases EV range and increases operating costs. Battery types other than lead-acid are being evaluated such as nickel-iron, gelled electrolyte lead-acid, nickel-cadmium, and sodium-sulfur. Also, improved methods of collecting EV performance data are being implemented, thermal management systems are being tested, and a prototype ultracapacitor is being tested as a possible alternative to conventional batteries.
1995-01-01
A study of primary sulfate emissions from a coal-fired boiler with FGD. [Flue gas desulfurization
An extended series of measurements at a conventional coal-fired boiler equipped with a wet-limestone flue gas desulfurization unit has shown that sulfate and sulfur dioxide removal efficiencies are dissimilar. The average SO2 scrubbing efficiency was 76% and was observed to decrease over a five-day operating cycle. Total sulfate scrubbing efficiency, averaging about 29%, was invariant throughout the operating cycle. (1 diagram, 3 tables)
1979-09-01
International Nuclear Information System (INIS)
This document contains a summarization of the results and insights from the Level 1 accident sequence analyses of internally initiated events, internally initiated fire and flood events, seismically initiated events, and the Level 2/3 risk analysis of internally initiated events (excluding fire and flood) for Surry, Unit 1. The analysis was confined to mid-loop operation, which can occur during three plant operational states (identified as POSs R6 and R10 during a refueling outage, and POS D6 during drained maintenance). The report summarizes the Level 1 information contained in Volumes 2--5 and the Level 2/3 information contained in Volume 6 of NUREG/CR-6144.
1990-10-22
Dynamic optimization of the benzene extractive distillation unit
Scientific Electronic Library Online (English)
Abstract in english A mathematical model has been developed for describing the dynamic operation of the N-formylmorpholine extractive distillation column and the corresponding solvent recovery column in the benzene extraction plant. The NRTL equation was used to calculate the equilibrium and thermodynamic properties of the mixtures. The validity of the model in terms of temperature, pressure and split fraction was examined using actual plant data at steady-state conditions. Comparison betwee (more) n model results and plant data shows good consistency. In order to improve the control of the process and selection of the optimal control strategy, the model was used to find the optimum values of the constants of the controllers with Nelder-Mead algorithm during unsteady-state operation by minimizing the deviation from steady-state conditions. The outcome of this study could be used by operators and engineers to increase the ...
2008-12-01
Estimating energy requirement in cashew (Anacardium occidentale L.) nut processing operations
Energy Technology Data Exchange (ETDEWEB)
This work deals with a study on estimation of energy consumption in eight readily defined unit operations of cashew nut processing. Data for analysis were collected from nine cashew nut mills stratified into small, medium and large categories to represent different mechanization levels. Series of equations were developed to easily compute requirements of electricity, fuel and labour for each of the unit operations. The computation of energy use was done using spreadsheet program on Microsoft Excel. The results of application test of the equations show that the total energy intensity in the cashew nut mills varied between 0.21 and 1.161MJ/kg. Electrical energy intensity varied between 0.0052 and 0.029MJ/kg, while thermal energy intensity varied from 0.085 to 1.064MJ/kg. The two identified energy intensive operations in cashew nut processing are cashew nut drying and cashew nut ...
2006-07-15
Dynamic security assessment in electric power systems
Energy Technology Data Exchange (ETDEWEB)
A new approach to dynamic security assessment in electric power systems is proposed. A power system is modeled as a dynamical system with random variable structure. Structural variations are caused by primary and secondary events. Primary events are state-independent disturbances representing line and unit faults and load changes and are modeled by random jump processes. Secondary events that represent forced line and unit outages and load sheddings are modeled through an aggregate representation of the protection system as random processes whose change in time corresponds to the crossing of switching surfaces by the state process. These switching surfaces are defined by the setting of the protective relays. Commensurate with this model a three-state decomposition of the operating conditions into normal, emergency, and partial load operating states is suggested. Transitions between these states are ...
1983-01-01
EDF approach on OD corrosion of SG tubes
Energy Technology Data Exchange (ETDEWEB)
The secondary side corrosion of steam generator tubes is the main degradation of components in operating power plants, strongly impacted by chemistry. This is why EDF has largely studied the chemical parameters in its 56 PWRs which might influence corrosion development. The results of 168 hideout returns of chemical species performed on the French plants allowed to draw conclusions on where chemical species are likely to concentrate in steam generators and on the influence of several contaminants on corrosion processes: sodium, chloride, phosphate, organic compounds, etc... Based on laboratory studies and plants feedback, new chemistry specifications were established and are now applied to EDF units to minimize corrosion and operating costs and to provide a good availability while maintaining an excellent safety. Boric acid is added in the secondary water of the 10 oldest units with Inconel 600 MA ...
1998-12-31
Unusual Recharge Processes near Arroyos of the Rio Grande Aquifer, El Paso/Juarez Area
The twin-cities of El Paso and Juarez share the water resources of the Hueco Bolson aquifer and overlying Rio Grande aquifer. Both aquifers span the international border between Mexico and the United States. Salinity in the Rio Grande aquifer varies widely, some parts of the shallow aquifer containing less than 1,000 mg/L total dissolved solids (TDS), other parts of the aquifer exceeding 5,000 mg/L TDS. One sizable part of the "Lower Valley" area, approximately 45 km below El Paso contains very dilute water near the outer edge of the floodplain. Historically it had been thought that the dilute waters in this location were derived from recharge from arroyos that drained proximal parts of the Hueco Bolson. Instead, our hydrogen and oxygen isotope data and carbon-14 data indicate that these dilute waters were derived from pre-dam infiltration of the Rio Grande. Relatively light and slightly evaporated pre-dam waters (-11.5 del O18) at the ...
2005-12-01
TVA's program to mitigate steam generator denting at Sequoyah and Watts Bar Nuclear Plants
International Nuclear Information System (INIS)
TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.
1983-09-25
International Nuclear Information System (INIS)
The first Advanced Boiling Water Reactor (ABWR) started commercial operation as Tokyo Electric Power Company's (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station Unit No.6 (K-6) in November 1996 and its sister Unit No.7 (K-7) in July 1997. The ABWR was developed to achieve higher reliability and safety margin while improving overall operability and economics. To achieve these goals, the optimal Boiling Water Reactor (BWR) technologies had been studied, tested and were finally adopted into the ABWR design. These technologies were called 'First of a Kind' and include the Reactor Internal Pump (RIP), Fine Motion Control Rod Drive (FMCRD), Reinforced Concrete Containment Vessel (RCCV), and integrated digital Instrumentation and Control System (I and C). Intensive development study, confirmation tests and verification tests were conducted by the plant equipment suppliers, electric utilities, and government ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately ...
1995-12-01
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division at Oak Ridge National Laboratory (ORNL) during the period October--December 1997. The section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within six major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Separations and Materials Synthesis, Fluid Structure and Properties, Biotechnology Research, and Molecular Studies. The name of a technical contact is included with each task described, and readers are encouraged to contact these individuals if they need additional information. Activities conducted within the area of Hot Cell Operations included ...
1999-02-01
International Nuclear Information System (INIS)
Wolsong 2, 3, and 4 are CANDU 6 pressurized heavy water nuclear power plants, each with a gross electrical output of 715 MW(e). The plants were constructed in the Republic of Korea during the 1990s. The three Wolsong units are based on the previous CANDU Wolsong Unit 1, declared in service in 1983. All four units are presently in commercial service. The Wolsong abnormal operating manuals were developed in a cooperative effort between Atomic Energy of Canada Limited, Korea Power Engineering Company staff, and Korea Electric Power Corporation. The role of Atomic Energy of Canada Limited in performing risk assessment studies and supporting CANDU stations for the preparation of emergency operating procedures has greatly benefited the Wolsong abnormal operating manual program. Korea Electric Power Corporation provided training and supervision, Korea Power Engineering ...
Overview of Chuetsu-oki earthquake and evaluation of seismic safety
International Nuclear Information System (INIS)
The Chuetsu-oki Earthquake strongly shook the Kashiwazaki-Kariwa Nuclear Power Station with the ground motions exceeding the design values. The incidents include a fire breakout of the Unit 3 transformer, a release of spilled water containing small amount of radioactive materials to the non-radiation control area and subsequently to the environment at Unit 6, and a release of radioactive material from the main turbine condenser through the main stack of Unit 7 due to the delay stooping the turbine gland steam ventilator by the operator in manually, while every unit in operation was safety shutdown in the automatic mode ensuring the three fundamental safety functions of (a) reactivity control, (b) removal of heat from the core and (c) confinement of radioactive materials. Following integrity evaluation and performance testing of the overall plant, seismic safety ...
2010-07-01
Decontamination performance in off-gas cleaning system of radioactive solid waste incineration unit
International Nuclear Information System (INIS)
At the Tokai Research Establishment of Japan Atomic Energy Research Institute, the radioactive solid waste incineration unit with a capacity of 100 kg/h was installed in 1979, since then the unit has been routinly operated. An off-gas cleaning system of the unit consists mainly of a primary and secondary ceramic filters, a heat resistant HEPA filter and a scrubber. A series of hot test was carried out to examine the docontamination performance for radionuclides in the off-gas cleaning system. In the test, simulated wastes contaminated with a known quantity of radionuclides were burned in the unit, and radioactive concentrations in the off-gas were measured. And then, the following data were obtained: a retention factor of radionuclides in a furnace and a decontamination factor for radionuclides in each of off-gas cleaning components. And also overall decontamination factors, defined ...
An analysis of thinning status for CANDU feeder pipes
Energy Technology Data Exchange (ETDEWEB)
The degradation status of outlet feeders in Wolsung unit 1 is analyzed using feeder thickness measurement data during overhaul period in 2000. DBs related to feeder thinning are made for parameters affecting dissolution rate and parameters affecting mass transfer rate. The initial thickness of feeder in Wolsung unit 1 is analyzed using initial thickness data of Wolsung unit 2, 3 and 4 as there are no initial thickness data of Wolsung unit 1. The initial thickness is varied as feeder diameter and bending degree, and CANDU feeders can be divided as 3 types for 2.5'' feeders and 3 types for 2'' feeders. The average initial thickness value for each type is defined as the initial thickness value of the type for Wolsung unit 1 feeders. Thinning rate is evaluated as the value dividing difference between initial thickness and minimum measured thickness by ...
2000-10-01
Some studies on physics parameters of Wolsung unit no. 1
International Nuclear Information System (INIS)
Nuclear physics parameters of the Wolsung CANDU-PHW reactor are computed by use of the PHWCELL computer code that is an improved version of LATREP. The PHWCELL code mainly computes cell parameters of heavy water moderated reactors, and modeling scheme of heavy water reactor cell calculations has been developed with the PHWCELL computer code. The reactor operating conditions considered in the study are cold zero power (CZP) and hot full power (HFP) with equilibrium poison. The cell parameters are also computed as a function of fuel burnup and the numerical results are compared with the results in PSR of the Wolsung unit and in the previous study. (author).
1980-01-01
SUNFLOWER ROTATIONAL SPEED CONTROL TOPICAL REPORT
A rotational speed control, tailored to the Sunflower system requirements, was designed and fabricated in breadboard, preprototype, and prototype configurations. These units were subjected to performance and environmental testing which has led to design improvements. Program efforts have yielded hardware capable of meeting all performance requirements and of operating under all the environmental conditions to which the units were exposed. Attractive design changes were identified and, in some cases, completed. These changes involve improvements in circuitry and packaging, the primary objectives of which are to eliminate startup bias batteries and reduce weight. It is recommended that the reported program be extended to implement these improvements. (auth)
1963-03-01
SM-2--HORIZONTAL STEAM GENERATOR ANALYSIS
ABS>A horizontal steam generator design for the SM-2 was lysis to determine the per formance of such a steam generator under steady state operating conditions and during load transients, The configuration for this design is a two- drum unit consisting of a heat exchanger unit and separator drum interconnected by integral riser and downcomer. An analog computer was used to analyze the steam generator behavior Wring load transients. The effect of various design changes on the response of the steam generator to step chages in load was determined. The horizontal steam generator design was compared to the existing vertical steam generator design for weight, size, price, and performance. (auth)
1959-11-01
Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985
Energy Technology Data Exchange (ETDEWEB)
Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.
1985-05-01
Electricity exchanges across international borders - 1983
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the electricity exchanges between the US and Mexico and Canada during calendar year 1983. The construction, operation and maintenance of any electric transmission facility which crosses an international border of the United States requires a Presidential Permit. These permits have been granted by the Department of Energy (DOE) since its formation in 1977. Between 1953 and 1977, these permits were issued by the former Federal Power Commission. Prior to 1953, they were issued by the President of the United States. Presidential Permits require that an annual report be filed by the permit holder detailing all transactions with the foreign country.
1984-09-01
American National Standard: for nuclear criticality control of special actinide elements
Energy Technology Data Exchange (ETDEWEB)
This standard is applicable to operations with the following: /sup 237/Np, /sup 238/Pu, /sup 240/Pu, /sup 241/Pu, /sup 242/Pu, /sup 241/Am, /sup 242m/Am, /sup 243/Am, /sup 243/Cm, /sup 244/Cm, /sup 245/Cm, /sup 247/Cm, /sup 249/Cf and /sup 251/Cf. Subcritical mass limits are presented for isolated fissionable units. The limits are not applicable to interacting units.
1981-01-01
A robust cell voltage monitoring system for analysis and diagnosis of fuel cell or battery systems
Energy Technology Data Exchange (ETDEWEB)
Cell voltage monitoring (CVM) systems are essential for the operation of fuel cell stacks and some battery systems, in the field as well as in the laboratory, because they allow the diagnosis and correction of problems that would otherwise go unnoticed and cause impaired performance or even permanent damage. A robust, safe, and low-cost design for a CVM unit is presented, using electromechanical relays as multiplexing switches. Some examples from the application of the unit on the University of Delaware's fuel cell battery hybrid buses are presented, including its use in automatically correcting anode flooding and diagnosing air channel blockage. (author)
2010-12-15
Development of processes for bench scale production of yellow cake from euxenite
International Nuclear Information System (INIS)
A Process for yellow cake production from local Euxenite was developed in Bench Scale by using sulphuric acid digestion with simultaneously ion-exchange and solvent extraction purification steps. Uranium was then precipitated as uranium diuranate by ammonia solution. Equipment used in this process includes : digestion vessels, columnar ion-exchange, solvent extraction and precipitation units Ore feed to the process could be adjusted up to 2 kilogram per day (8 hours operation) with yellow cake product purity meet the requirement of Usaec standard of about 10-50 gram per day. Included in this experiment are the leaching characteristics of the ore, the design and construction of continuous columnar 4-cycle ion exchange unit, determination of the extraction and stripping stages of a gravity flow mixer-settler and the design and construction of continuous yellow cake precipitation unit with large grain size ...
1985-01-01
A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit
Energy Technology Data Exchange (ETDEWEB)
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.
1996-08-01
Display unit of speedometer for automobile
Energy Technology Data Exchange (ETDEWEB)
This patent describes a display unit of a speedometer for an automobile, comprising: a constant speed running circuit capable of producing output signals indicative of a desired car speed; an actual car speed operational circuit capable of producing output signals indicative of actual car speed; a comparing circuit for comparing the amplitudes of the output signals of the constant speed running operational circuit and the actual car speed operational circuit; bar graph decoders receiving the output signals from the constant speed running operational circuit and the actual car speed operational circuit; an EX-OR circuit having inputs coupled to respective bar graph decoders and having an output; and OR circuit having inputs coupled to respective bar graph decoders and having an output; selector means coupled to the output of the EX-OR circuit and the output of ...
1987-03-03
Dilute chemical cleaning of PWR steam generators off-line cleaning process evaluation
Energy Technology Data Exchange (ETDEWEB)
This project evaluated the feasibility of using a low-concentration (approx. 0.5 wt %) chemical cleaning process to remove corrosion product deposits from steam generator surfaces and magnetite from tube-to-support plate crevices of PWR steam generators. The primary objective was to develop a dilute process that could be safely applied at scheduled intervals, such as during normal refueling outages, to maintain a clean operating condition in the steam generator. The dilute chemical cleaning process developed in this project was demonstrated successfully on two model generators which were operated on faulted chemistry by DOE/CRC at Commonwealth's State Line Facility. Unit 5 was cleaned after 48 days of operation with 1% seawater fouling, and Unit 6 was cleaned after 112 days of operations with Lake Michigan water. This report describes work leading to ...
1983-07-01
Dilute chemical cleaning of PWR steam generators off-line cleaning process evaluation
International Nuclear Information System (INIS)
This project evaluated the feasibility of using a low-concentration (approx. 0.5 wt %) chemical cleaning process to remove corrosion product deposits from steam generator surfaces and magnetite from tube-to-support plate crevices of PWR steam generators. The primary objective was to develop a dilute process that could be safely applied at scheduled intervals, such as during normal refueling outages, to maintain a clean operating condition in the steam generator. The dilute chemical cleaning process developed in this project was demonstrated successfully on two model generators which were operated on faulted chemistry by DOE/CRC at Commonwealth's State Line Facility. Unit 5 was cleaned after 48 days of operation with 1% seawater fouling, and Unit 6 was cleaned after 112 days of operations with Lake Michigan water. This report describes work leading to the model ...
Eielson Air Force Base OU-1 baseline risk assessment
Energy Technology Data Exchange (ETDEWEB)
This Baseline Risk Assessment report is the second volume in a set of three volumes for operable Unit 1 (OU-1). The companion documents contain the Remedial Investigation and the Feasibility Study. Operable Unit 1 (OU-1) is one of several groups of hazardous waste sites located at Eielson Air Force Base (AFB) near Fairbanks, Alaska. The operable units at Eielson are typically characterized by petroleum, oil, lubricant/solvent contamination, and by the presence of organics floating at the water table. In 1989 and 1990, firms under contract to the Air Force conducted field studies to gather information about the extent of chemical contamination in soil, groundwater, and soil air pore space (soil gas) at the site. This report documents the results of a baseline risk assessment, which uses the 1989 and 1991 site characterization database to quantify the potential ...
1993-09-01
Characterization and remediation of highly radioactive contaminated soil at Hanford
Energy Technology Data Exchange (ETDEWEB)
The Hanford Site, Richland, Washington, contains over 1,500 identified waste sites and numerous groundwater plumes that will be characterized and remediated over the next 30 years. As a result of the Hanford Federal Facility Agreement and Consent Order, the US Department of Energy (DOE) has initiated a remedial investigation/feasibility study (RI/FS) at the 200-BP-1 operable unit. The 200-BP-1 RI/FS is the first Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) investigation on the Hanford Site that involves highly radioactive and chemically contaminated soils. The initial phase of site characterization was designed to assess the nature and extent of contamination associated with the source waste sites within the 200-BP-1 operable unit. Characterization activities consisted of drilling and sampling, chemical and physical analysis of samples, and development of a conceptual ...
1993-09-01
Challenges for Lithuania: Ignalina NPP Early Closure
International Nuclear Information System (INIS)
As a condition of accession into the European Union (EU), Lithuania is committed to the closure and decommissioning of Ignalina NPP comprising two RBMK-1500 reactor units (Fig. 1). It was agreed in a special protocol to the Accession Treaty that, in return for adequate EU financial assistance, Unit 1 would be closed before 2005 and Unit 2 by the end of 2009. The first unit was duly shut down on December 31, 2004. Lithuania, which has borders with Russia (Kaliningrad territory), Poland, Latvia and Belarus, spent fifty years as part of the Soviet Union and was deeply integrated into its economy and electrical infrastructure. At the break-up of the USSR, Lithuania inherited electricity generating capacity designed to supply the north-west region including ownership of Ignalina NPP located in the north-east of the country. Ignalina NPP Unit 1 was commissioned in 1983, ...
2008-01-01
Energy and exergy analyses of malt drink production in Nigeria
Energy Technology Data Exchange (ETDEWEB)
Energy requirements and exergy inefficiencies for processing of malt drink were estimated for a Nigerian brewery. The process was divided into twenty-one basic unit operations and grouped into four main group operations: silo house, brew house, filter room and packaging house. The energy intensity for processing a batch of 9.8 tonnes brew grains to 562 hl of malt drink was estimated as 261.63 MJ/hl consisting of electrical (41.01%), thermal (58.81%) and manual (0.19%) of the total energy. The most energy intensive group operation was the Packaging House operation, followed by the Brew House operation with energy intensities of 223.19 and 35.94 MJ/hl, respectively. The exergy analysis revealed that the packaging house operation was responsible for most of the inefficiency (92.16%) followed by brew house operation (7.17%) ...
2010-12-15
W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)
Energy Technology Data Exchange (ETDEWEB)
Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.
1997-02-14
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2006-11-13
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2005-11-23
Status of steam generators in Spain
International Nuclear Information System (INIS)
There are a total of nine operational nuclear plants in Spain totalling 7.350 MWe. These units produced 54.265 x 106 KWh in 1990, 36% of the total generation in Spain. Seven of these plants are of the PWR type. The first plant in operation was Jose Cabrera (ZORITA) in 1968, one loop Westinghouse plant with a model 24 Steam Generator. Due to the design margin and careful operation of the Steam Generator of this plant its performance have been very good, with only 5% tubes plugged after 23 years of operation. This is one of the few units in the world that remains in phosphate chemistry. During the period 1981-1985 a total of four units, two in Almaraz and two in Asco entered in operation. These three loop s Westinghouse units use model D-3 preheater Steam Generators. The poor design and manufacture of ...
1991-09-16
Energy Technology Data Exchange (ETDEWEB)
Supplement 2 to the Safety Evaluation Report for Mississippi Power and Light Company, et. al, joint application for licenses to operate the Grand Gulf Nuclear Station, Units 1 and 2, located on the east bank of the Mississippi River near Port Gibson, in Claiborne County, Mississippi, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. This supplement reports the status of certain items that had not been resolved at the time of publication of the Safety Evaluation Report.
1982-06-01
Energy Technology Data Exchange (ETDEWEB)
This Waste Management Plan describes waste management and waste minimization activities for Group 3, Other Surface Soils Remediation Sets 4-6 (Phase II) at the Idaho Nuclear Technology and Engineering Center located within the Idaho National Laboratory. The waste management activities described in this plan support the selected response action presented in the Final Record of Decision for Idaho Nuclear Technology and Engineering Center, Operable Unit 3-13. This plan identifies the waste streams that will be generated during implementation of the remedial action and presents plans for waste minimization, waste management strategies, and waste disposition.
2006-07-01
Methanol production FPSO plant concept using multiple microchannel unit operations
British Library Electronic Table of Contents (United Kingdom)
Remote, offshore gas reserves have long been a challenging deepwater petroleum resource to tap. Natural gas in many offshore regions is plentiful, but lacks access to the market because of the logistical challenges and costs. Most large offshore gas discoveries are capped, and gas associated with oil production is re-injected into the reservoir or is flared. A more attractive option is to convert the gas into a liquid product on a floating production, storage, and offloading (FPSO) vessel. However, some conventional process technologies are not well suited for operation on floating vessels that are highly space and weight constrained and may challenge vessel stability during inclement weather. Microchannel process technology units under development offer intensified processes that are suit...
2008-01-01
Investigation of GPS/IMU Positioning System for Mining Equipment
Energy Technology Data Exchange (ETDEWEB)
The objective of this project is to investigate the applicability of a combined Global Positioning System and Inertial Measurement Unit (GPS/IMU) for information based displays on earthmoving machines and for automated earthmoving machines in the future. This technology has the potential of allowing an information-based product like Caterpillar's Computer Aided Earthmoving System (CAES) to operate in areas with satellite shading. Satellite shading is an issue in open pit mining because machines are routinely required to operate close to high walls, which reduces significantly the amount of the visible sky to the GPS antenna mounted on the machine. An inertial measurement unit is a product, which provides data for the calculation of position based on sensing accelerations and rotation rates of the machine's rigid body. When this information is coupled with GPS it results in a ...
2006-09-13
International Nuclear Information System (INIS)
Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)
1998-06-01
Hydrogen absorption behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
The deuterium uptake behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1 was analyzed in terms of longitudinal location, operation time, and coolant temperature. The results were compared with those obtained from Canadian CANDU reactors. The amount of deuterium uptake was higher at the outlet part than at the inlet part and was also higher when subjected to a longer operation time and a higher coolant temperature. The hydrogen uptake of Zr-2.5Nb in a hydrogen gas atmosphere was dependent on the microstructure of the alloy. The aged Zr-2.5Nb consisting of {alpha}-Zr and {beta}-Zr phases. The hydrogen in the alloy decreased the rate of oxidation. This could be explained in terms of the cathodic controlled reaction of Zr-2.5Nb oxidation. (author)
1998-08-01
Field Sampling Plan for the Operable Units 6-05 and 10-04 Remedial Action, Phase IV
Energy Technology Data Exchange (ETDEWEB)
This Field Sampling Plan outlines the collection and analysis of samples in support of Phase IV of the Waste Area Group 10, Operable Units 6-05 and 10-04 remedial action. Phase IV addresses the remedial actions to areas with the potential for unexploded ordnance at the Idaho National Laboratory Site. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. The remedial action consists of removal and disposal of ordnance by high-order detonation, followed by sampling to determine the extent, if any, of soil that might have been contaminated by the detonation activities associated with the disposal of ordnance during the Phase IV activities and explosives during the Phase II activities.
2006-11-14
Dynamic voltage control by remote voltage regulation for pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.
1988-08-01
Adapting United States training practices to European utilities
International Nuclear Information System (INIS)
The factors which must be considered in the process of adapting United States nuclear utility training programs to the needs of a European utility are discussed. Following a review of the present situation and drawing up of a new training program, the management commitments in terms of personnel and finance must be considered. Short term, medium and long term programs are outlined. The long term objectives should include the establishment of a total training centre. This facility should be capable of providing all the training necessary to operate a power plant safely. This would include specific simulator training, classroom training for operators, technician training, staff training, management training etc. In addition to a simulator, it should include an emergency response facility to train personnel. (U.K.).
A numerical investigation of scale-up effects on coke yields of a thermal cracking Riser reactor
Energy Technology Data Exchange (ETDEWEB)
A validated computational fluid dynamics (CFD) computer code, ICRKFLO, was used to investigate the scale-up effects on the coke yields of thermal cracking riser factors. Comparisons were made for calculated coke yields of pilot- and commercial-scales riser units. Computational results show that the riser aspect ratio, reaction temperature, particle residence time, and particle/oil ratio have major impacts on the coke yield. A computational experiment was conducted to determine optimal operating conditions for a conceptual design of a commercial-scale riser unit. This experiment showed that the performance loss in scale-up from pilot to commercial scale may be almost completely recovered through optimizing the operating conditions after scale-up using the CFD simulations as a guide.
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
Hybrid models for solving unit commitment problem have been proposed in this paper. To incorporate the changes due to the addition of new constraints automatically, an expert system (ES) has been proposed. The ES combines both schedules of units to be committed based on any classical or traditional algorithms and the knowledge of experienced power system operators. A solution database, i.e. information contained in the previous schedule is used to facilitate the current solution process. The proposed ES receives the input, i.e. the unit commitment solutions from a fuzzy-neural network. The unit commitment solutions from the artificial neural network cannot offer good performance if the load patterns are dissimilar to those of the trained data. Hence, the load demands, i.e. the input to the fuzzy-neural network is considered as fuzzy variables. To take into account the uncertainty in ...
2001-11-01
International Nuclear Information System (INIS)
In this chart review the authors describe 51 cases of PSOAS abscess treated at Hospital Universitario del Valle in Cali, Colombia in the last 10 years. It is not a rare condition and require high index of suspicion. epidemiology, bacteriology, diagnosis and treatment are discussed.
2006-06-01
UK PubMed Central (United Kingdom)
A mollusciciding campaign was begun in Cul-de-Sac Valley, St Lucia, at the end of 1970, following several years of epidemiological studies in which transmission of Schistosoma mansoni...Full Text Available
1976-01-01
Prediction of a Rift Valley fever outbreak
UK PubMed Central (United Kingdom)
El Niño/Southern Oscillation related climate anomalies were analyzed by using a combination of satellite measurements of elevated sea-surface temperatures and subsequent elevated rainfall and...Full Text Available
2009-01-20
How representative was the 1996 VOTALP Mesolcina Valley campaign?
Energy Technology Data Exchange (ETDEWEB)
Each meteorological measurement reflects the conditions under which it was obtained, e.g. site, weather, and instrumentation. It is shown how the VOTALP Intensive Observation Periods (IOPs) were embedded in the climatic context of the summer months of 1996. (author) 1 fig., 2 refs.
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
Results related to the experimental measurement campaign to characterize atmospheric aerosol carried out near Avigliana (Turin) from 18 to 22 October 1994 are presented in this paper. In the frame of the project aimed at evaluating the impact of the mountain motor way A-32 Rivoli-Bardonecchia-Frejus on the Susa Valley environment and on man the present measurement campaign is the second, and last, one envisaged in the project. The sampling place is in the initial part of the Susa Valley while previous measurements were carried out in the high part of it. Mass mean concentrations result greater in the low than in the high part of the valley approximately by a factor of 3. It is not possible to prove a difference between the 3 sampling positions transversely placed from 20 to 80 m. in comparison with the motor way axis. Whereas mass mean concentrations dropped substantially due to atmospheric precipitations during the last ...
1995-10-01
A socioecological approach to the control of Schistosoma mansoni in St Lucia
UK PubMed Central (United Kingdom)
Systematic observations of man/water contact in a valley endemic for S. mansoni in St Lucia were carried out prior to the introduction of a household water supply. The observations...Full Text Available
1976-01-01
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...
1987-09-13
Stratigraphy and sedimentary environment of the Coalspur Formation
Energy Technology Data Exchange (ETDEWEB)
The Coalspur Formation is a continental succession of interbedded mudstone, siltstone and fine grained sandstone with subordinate coarser grained sandstone layers and channel lag deposits. Chert-pebble conglomerate (the Entrance conglomerate) occurs at the base of the formation, and coal beds interbedded with coaly shale and numerous thin bentonites occur in the upper part of the formation. An economically significant amount of high-quality thermal coal occurs within the upper, Paleocene part of the formation named the Coalspur coal zone. Coal from this zone, also known as the Coal Valley coal zone is being exploited in the Coal Valley Mine. 17 refs., 4 figs.
1990-01-01
Strained silicon for quantum computing
Energy Technology Data Exchange (ETDEWEB)
Strains in multivalley semiconductors can destroy the strict equivalence of the valleys that is demanded by cubic symmetry. Significant changes in the properties of a semiconductor may result. A proposed implementation of quantum computing with donor atoms in silicon would suffer from alterations of the donor wave functions caused by strains that are produced by fabrication processes. Deliberately straining the silicon to an extent that removed all but one valley from participation in the lowest donor state, would prevent further changes in the wave function by strain. The strain required can be achieved with established technology for depositing silicon on SiGe alloys. (author)
2002-03-07
Shawnee flue gas desulfurization computer model users manual
Energy Technology Data Exchange (ETDEWEB)
In conjunction with the US Enviromental Protection Agency sponsored Shawnee test program, Bechtel National, Inc., and the Tennessee Valley Authority jointly developed a computer model capable of projecting preliminary design and economics for lime- and limestone-scrubbing flue gas desulfurization systems. The model is capable of projecting relative economics for spray tower, turbulent contact absorber, and venturi-spray tower scrubbing options. It may be used to project the effect on system design and economics of variations in required SO/sub 2/ removal, scrubber operating parameters (gas velocity, liquid-to-gas (L/G) ration, alkali stoichiometry, liquor hold time in slurry recirculation tanks), reheat temperature, and scrubber bypass. It may also be used to evaluate alternative waste disposal methods or additives (MgO or adipic acid) on costs for the selected process. Although the model is not intended to project the economics of an ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
A joint materials test program developed by the Institute for Mining and Minerals Research (IMMR) and the Tennessee Valley Authority (TVA) involved the postexposure mechanical properties and corrosion behavior of candidate structural materials in an experimental, atmospheric fluidized-bed combustor (AFBC). This combustor was operated by Accurex Corporation at Research Triangle Park, North Carolina, under the direction of TVA. The materials studied were Type 304, Type 310, and INCOLOY alloy 800 in the form of disc coupons with and without crevice configurations. Type 304 was also used for mechanical property measurements. The alloys were exposed to the combustor environment at about840/sup 0/C for approximately 330 hours. The ranking in terms of decreasing weight loss was: (1) Type 304, (2) Type 310, and (3) INCOLOY alloy 800. The presence of tight crevices did not enhance the corrosion rate. In addition, the corrosion rates, based on the weight ...
1984-06-01
United States Department of Energy breeder reactor staff training domestic program
Energy Technology Data Exchange (ETDEWEB)
Two US DOE projects in the Pacific Northwest offer unique on-the-scene training opportunities at sodium-cooled fast-reactor plants: the Fast Flux Test Facility (FFTF) near Richland, Washington, which has operated successfully in a wide range of irradiation test programs since 1980; and the Experimental Breeder Reactor II (EBR-II) near Idaho Falls, Idaho, which has been in operation for approximately 20 years. Training programs have been especially designed to take advantage of this plant experience. Available courses are described.
1984-01-01
The analysis of temperature distribution for surveillance Capsule in reactor vessel of YGN unit 1
International Nuclear Information System (INIS)
Generally, Hardening and irradiated brominating phenomena are occurred in the reactor vessel under operation conditions by atomic cavities and creation of impurity atoms which are led by high fast neutron flux. To assure the mechanical integrity of pressure vessel until the end of power plant life after monitoring the sample specimens on the vessel inside, a series of tests is performed over the retrieved surveillance capsule to examine the changes according to the plant operation in accordance with regulations. Monitoring surveillance capsules attached to neutron shield wall of outer core are consists of impact sample, tensile sample and temperature monitor
2007-05-10
Regeneration behavior of light-duty catalytic trap oxidizer systems
A catalytic trap oxidizer based on a radial flow metal mesh filter was developed for use as an after treatment device on light-duty diesel vehicles. A complete system for assisted regeneration was devised to enable this unit to operate without blocking during all normal driving modes. The integration of the catalyzed trap and regeneration system with the vehicle to provide a practical system for the reduction of diesel particulate emissions is discussed. To date, many prototype catalytic trap and regeneration system installations have been completed on various test vehicles, both naturally aspirated and turbocharged. The operational conditions and test results from a selection of these studies are presented.
1984-01-01
Low Power and Shutdown Risk Assessment Benchmarking Study
(B204)Probabilistic risk assessment (PRA) insights are now used by the United States Nuclear Regulatory Commission (USNRC) to confirm the level of safety for plant operations and to justify changes in nuclear power plant operating requirements, both on an exception basis and as changeds to a plant's licensing basis. This report examines qualitative and quantitative risk assessments during shutdown plant states, providing feedback to utilities in the use of qualitative models for outage risk management, and also providing input to the development of the American Nuclear Society (ANS) Low Power and Shutdown PRA Standard.
2002-12-15
Low Power and Shutdown Risk Assessment Benchmarking Study
Energy Technology Data Exchange (ETDEWEB)
(B204)Probabilistic risk assessment (PRA) insights are now used by the United States Nuclear Regulatory Commission (USNRC) to confirm the level of safety for plant operations and to justify changes in nuclear power plant operating requirements, both on an exception basis and as changeds to a plant's licensing basis. This report examines qualitative and quantitative risk assessments during shutdown plant states, providing feedback to utilities in the use of qualitative models for outage risk management, and also providing input to the development of the American Nuclear Society (ANS) Low Power and Shutdown PRA Standard.
2002-12-15
Florida State University - Explores! World Headquarters
EXPLORES! (EXPloring and Learning the Operations and Resources of Environmental Satellites!) is an educational outreach program developed at Florida State University with the intention of introducing weather satellite receiving technology into the primary and secondary school classrooms. The website furnishes real time high resolution imagery and tropical updates. Visitors can find historical accounts of the civilian weather satellites launched by the United States. Educators can discover kindergarten through twelfth grade resources and curriculum. Users can learn how to become a part of the WXSAT-L community email list where weather satellite professionals, amateurs, and hobbyists converse about scientific, tracking, launching, and operations information.
Design of self-tuning PID power system stabilizer for multimachine power systems
Energy Technology Data Exchange (ETDEWEB)
A self-tuning PID (proportional-integral-derivative) power system stabilizer (PSS) is presented for improving the dynamic stability of a multimachine power system over a wide range of operating conditions. In order to maintain good damping characteristic when there is a drastic change in system operating condition, the gain settings are adapted in real time based on the continuously measured system inputs and outputs. The proposed self-tuning stabilizer has a decentralized structure and only local measurements within each generating units are required for the adaptation process. The effectiveness of the proposed stabilizer is demonstrated by an example.
1988-08-01
Continuous coal hydrogenation; processes and products, annual report July 1981 to June 1982
Energy Technology Data Exchange (ETDEWEB)
The first stage of the continuous coal hydrogenation unit has been used to test a number of coals with different processing strategies. This work has shown that conversion increases with product recycle, however after the second pass the increase is small but operability of the reactor is considerably improved. A kinetic model for the aromatic saturation of the recycle solvent in the second stage has been developed and will be used in the selection of conditions for oil upgrading processes. New insights into the structural composition of coal derived materials have been made due to the refinement of chromatographic or solubility separation analyses into routine operations and the development of a new technique in NMR spectroscopy.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The potential retinal hazard of dental visible-light photopolymerization units and the efficacy of protective lenses for reducing the potential hazards were assessed. The spectral radiance profiles of 11 visible-light photopolymerization units were measured; and the results were then weighted according to the American Conference of Governmental Industrial Hygienists (ACGIH) Blue Light and Thermal Hazard Functions. The results indicate that there are no thermal hazards to the retina even for the worst case condition. None of the blue-light hazard maximum permissible exposure times is short enough to be of concern unless the individual operator chooses to focus on the light source for an extended period. Those individuals who elect to stare at the light during curing procedures should consider the purchase of protective lenses. The special transmission profiles of 16 protective lenses were measured and new permissible ...
1986-11-01
The use of alloy 800 in the THTR steam generator
International Nuclear Information System (INIS)
In 1972 a consortium consisting of Gebruder Sulzer A.G., Winterthur and EVT, Energie- und Verfahrenstechnik G.m.b.H., Stuttgart, was awarded the contract by HBR, Hochtemperatur Reaktorbau G.m.b.H., Koln/Mannheim, for the design, manufacture and installation of the 6 steam generator units for the prototype 300 MWe Thorium High Temperature Reactor (THTR) at Schmehausen, Germany. The design and manufacture of the 6 units is done by Sulzer; installation of the units as well as the manufacture of the external pipework and headers is done by EVT. The units are built under semiclean conditions in a special workshop at CCM-Sulzer in mantes, France. This workshop had been used previously for the manufacture of the steam generators for the nuclear power plants St. Laurent I, II, Vandellos (500 Mwe each) and EL-4 (70 Mwe). The present paper defines the operating conditions and the chemical ...
Energy Technology Data Exchange (ETDEWEB)
It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is ...
2007-07-01
International Nuclear Information System (INIS)
It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on ...
2007-05-10
Energy Technology Data Exchange (ETDEWEB)
In this work, a model for determining the optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 is developed, which is to minimize economic loss caused by inadvertent trip and the system failure. This model uses cost benefit analysis method and the part for optimal inspection period considers the human error. The model is based on three factors as follows: (i) The cumulative failure distribution function of the safety system, (ii) The probability that the safety system does not operate due to failure of the system or human error when the safety system is needed at an emergency condition and (iii) The average probability that the reactor is tripped due to the failure of system components or human error. The model then is applied to evaluate the safety system in Wolsung Nuclear Power Plant Unit 1. The optimal replacement periods which are calculated with proposed model differ ...
1996-01-01
International Nuclear Information System (INIS)
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of ...
2006-06-13
Pumped-storage: peak generation or operating reserve
Energy Technology Data Exchange (ETDEWEB)
The trade-off which must be established between the various functions of pumped-storage plants is examined. A compromise between supply security and economic planning can be found only by coordinated planning of pumped-storage units and thermal generation plants. A model used by Electricite de France (EDF) to ensure optimized daily planning of thermal and pumped-storage units is described. The model, called the DEMETER model, ensures the optimization of the daily planning of thermal and pumped-storage plants. The model iterates between two levels: coordination where the prices of the generated energy and the operating reserve are determined to adjust generation to load and keep a sufficient reserve; and decomposition where the schedule of each unit is optimized on the basis of the above prices and taking into account local constraints such as unavailability, and minimum shut down time. The role of EDF ...
1984-08-01
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
Energy Technology Data Exchange (ETDEWEB)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.
2008-10-15
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
International Nuclear Information System (INIS)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.
2008-10-01
Measures for reliability improvement of on-site power plant at steel works
Energy Technology Data Exchange (ETDEWEB)
This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the ...
1988-04-15
Gas and coal-fired combined cycle plants
Energy Technology Data Exchange (ETDEWEB)
Fully-fired combined cycle plants utilizing the high temperature gas turbine discharge as gas intake for a coal-fired steam generator were developed in the 1960's. Long-term experience and the excellent reliability statistics of the gas turbines of these plants have proven that the thermodynamic, economical and ecological advantages of combined cycle units over conventional units strongly suggest such plants for fossil-fuel applications. This paper describes the design and operation of these plants. Topics are Gersteinwerk Unit K combined-cycle power plant, plant design concept, design criteria and performance, gas turbines, steam generators, steam turbines, various modes of operation, typical plant start-up, environmental considerations, prototype plants and topping old steam turbine plants. It concludes that combined-cycle plants provide efficiencies over 45% with low ...
1986-01-01
Energy and cost analysis of organic fertilizer production in Nigeria
Energy Technology Data Exchange (ETDEWEB)
Energy study was conducted in an organic fertilizer production plant in Nigeria, to determine the energy consumption patterns and the associated costs for the production of both powdered and pelletised fertilizer. Analysis was conducted for a daily production of 9000 kg of the finished products. Eight and nine defined unit operations were required for production of powder and pellets, respectively. The electrical and manual energy required for the production of powder were 94.5 and 5.6% of the total energy, respectively, with corresponding 93.9 and 5.1% for the production of pellets. The respective average energy intensities were estimated as 0.28 and 0.35 MJ/kg for powder and pellets. The most energy intensive operation was identified as the pulverizing unit with energy intensity of 0.09 MJ/kg, accounting for respective proportions of 33.4 and 27.0% of the total energy for production of powder and ...
2010-01-15
Tube problems: worldwide statistics reviewed
International Nuclear Information System (INIS)
EPRI's Steam Generator Strategic Management Project issues an annual report on the progress being made in tackling steam generator problems worldwide, containing a wealth of detailed statistics on the status of operating units and degradation mechanisms encountered. A few highlights are presented from the latest report, issued in October 1993, which covers the period to 31 December 1992. (Author).
This decision document presents the selected remedial action for the former Asarco Tacoma Smelter Facility and adjacent slag peninsula, in Ruston and Tacoma, Washington. This Record of Decision (ROD) describes the final cleanup remedy for soil, slag and surface water and disposal of hazardous soils, demolition debris, and residential soils. This ROD is intended to be an interim action for ground water.
1996-04-01
The main steam piping of nuclear power plant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. ...
1996-01-01
Single chip linear array picture processor
Energy Technology Data Exchange (ETDEWEB)
A CMOS programmable picture processor with its own photodiode array is presented. The circuit is novel in that it includes an instruction set that permits most low-level picture processing operations. The chip is a parallel machine with a processing unit for each picture element. Images are binarized and are processed line by line. An experimental chip has been designed and is under fabrication. 2 references.
1983-01-01
A population-based, cohort study was conducted to determine the importance of Gulf War deployment to Southwest Asia, from 1 August 1990 to 31 December 1991, in explaining neurologic mortality and peripheral nerve disease among United States military worki...
2003-01-01
Reliability analysis of diesel generators of Wolsung unit 1
Energy Technology Data Exchange (ETDEWEB)
As a maintenance optimization project to improve the safety of Wolsung NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be mush improved if the suggested improvement options are implemented. (Author) 6 refs., 1 tab.
1997-05-01
Reliability analysis of diesel generators of Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
As a maintenance optimization project to improve the safety of Wolsung NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be much improved if the suggested improvement options are implemented.
1997-05-01
Overview of the nuclear fuel cycle
International Nuclear Information System (INIS)
The use of nuclear reactors to provide electrical energy has shown considerable growth since the first nuclear plant started commercial operation in the mid 1950s. Although the main purpose of this paper is to review the fuel cycle capabilities in the United States, the introduction is a brief review of the types of nuclear reactors in use and the world-wide nuclear capacity.
1981-11-03
British Library Electronic Table of Contents (United Kingdom)
Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.
2008-01-01
Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.
2008-05-01
Energy Technology Data Exchange (ETDEWEB)
A decision must be made regarding whether the United State`s stockpile of neptunium should be discarded into the waste stream or kept for the production of Pu-238. Although the cost of long term storage is not inconsequential, to dispose of the material means the closing of our option to maintain control over our Pu-238 stockpile. Within the Fuels and Materials Examination Facility at Hanford there exists a remotely operated facility that can be converted for neptunium storage. This paper describes the facility and the anticipated handling requirements.
1993-06-01
International Nuclear Information System (INIS)
A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).
1988-05-19
Energy Technology Data Exchange (ETDEWEB)
The mission of the Heavy Water portion of D Area (or 400 Area) at SRS is to purify the site inventory of heavy water for storage in the Reactor Areas for future DOE missions.
1996-01-01
An experimental plan for improvement of failed fuel monitoring system in CANDU reactor
Energy Technology Data Exchange (ETDEWEB)
An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.
2003-10-01
Actinide chemistry: From test tube to billion dollar plant-A BNFL perspective
British Nuclear Fuels (BNFL) is currently operating its third generation of nuclear plant for the management of irradiated nuclear fuel. Development for the fourth generation plant must meet requirements for processing higher burn-up fuel with lower unit costs, lower environmental impact, better process control, and more flexible control of actinides. .
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
A string sieve is proposed which includes a frame, a sifting surface made of string, a device for attaching the strings made in the form of rollers installed in staggered order and a tensing device attached to traverses. To improve the effectiveness of sifting by self cleaning of the sifting surface during operation, the rollers are installed on the traverses by means of a unit of hinges, whose elastic elements are made with varying rigidity.
1983-01-01
2007 SB14 Source Reduction Plan/Report
Energy Technology Data Exchange (ETDEWEB)
Aqueous solutions (mixed waste) generated from various LLNL operations, such as debris washing, sample preparation and analysis, and equipment maintenance and cleanout, were combined for storage in the B695 tank farm. Prior to combination the individual waste streams had different codes depending on the particular generating process and waste characteristics. The largest streams were CWC 132, 791, 134, 792. Several smaller waste streams were also included. This combined waste stream was treated at LLNL's waste treatment facility using a vacuum filtration and cool vapor evaporation process in preparation for discharge to sanitary sewer. Prior to discharge, the treated waste stream was sampled and the results were reviewed by LLNL's water monitoring specialists. The treated solution was discharged following confirmation that it met the discharge criteria. A major source, accounting for 50% for this waste stream, is metal machining, cutting and ...
2007-07-24
Study of radionuclide contributing to dose rates in 540 MWe plant environment
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas ...
2005-11-23
Viewpoint: Space System Negation in the Context of Space Policy and Law
British Library Electronic Table of Contents (United Kingdom)
For 21st century warfare, space is the unquestioned new high ground for military operations. The United States (U.S.) has relied on satellites for significant support to military operations and activities since Desert Storm in 1991. Indeed, the U.S. enjoys an asymmetric advantage in modern warfare utilizing our space capabilities. States with interests hostile to the U.S. believe that the significant dependence on space assets by the U.S. military could become its "Achilles heel" in future combat operations. What are the legal and policy bases for the U.S. to respond to threats to space systems that provide support to our military forces? Should the U.S. rely on space arms control initiatives to ensure security in space? This Viewpoint analyzes the international space law regime and U.S. N...
2007-01-01
Current waste-management practices and operations at Oak Ridge National Laboratory, 1982
Energy Technology Data Exchange (ETDEWEB)
The need for efficient management of industrial chemical wastes, especially those considered hazardous or radioactive, is receiving increased attention in the United States. During the past five years, several federal laws have addressed the establishment of stronger programs for the control of hazardous and residual wastes. At a facility such as Oak Ridge National Laboratory (ORNL), an efficient waste management program is an absolute necessity to ensure protection of human health and compliance with regulatory requirements addressing the treatment and disposal of hazardous, nonhazardous, and radioactive wastes. This report highlights the major regulatory requirements under which the Laboratory must operate and their impact on ORNL facilities. Individual waste streams, estimates of quantities of waste, and current waste management operations are discussed.
1982-09-01
Brief laboratory report: surgical drape flammability.
Fires in the operating room continue to present a hazard to patients, at times with catastrophic and debilitating results. Recent data from closed claim files reveal oxygen, electrosurgical unit (ESU), and surgical drapes are common components of the fire triangle in the operating room. In this era of biotechnological sophistication, why are surgical drapes flammable? The purpose of this study was to test the flammability of different surgical drape materials and to determine the time to ignition using a bipolar ESU device in 21%, 35%, and 100% oxygen concentrations. Results show that regardless of oxygen concentration surgical drapes, when exposed to close contact with the ESU, are flammable. Time to ignition decreases with increasing concentrations of oxygen as expected. One of the surgical drapes tested was advertised to the hospital as nonflammable. Future research should focus on surgical drape materials and aim to ...
2006-10-01
Representation blocks of conformal fields for the N=4 SU(2)$_{k}$ superconformal algebras
The representation theories of the SU(2).sub(k)-extended N=4 superconformal algebras (SCAs) with arbitrary level k are developed being based on their Feigin-Fuchs representations found recently by the present author. A basic unit of the representation blocks consisting of eight \\lq\\lq boson-like\\rq\\rq\\ and eight \\lq\\lq fermion-like\\rq\\rq\\ conformal fields is found to describe arbitrary representations of the $N$=4 SU(2)$_k$ SCAs, including {\\it unitary} and {\\it nonunitary} representations. The transformation properties of the fundamental sets of the conformal fields under the $N$=4 SU(2)$_k$ superconformal symmetries are given. Then, the whole sets of the charge-screening operators of the $N$=4 SU(2)$_k$ SCAs are identified out of the sixteen conformal fields in the basic unit of the representation blocks. The conditions for the {\\it eligible} charge-screening operators are analyzed in ...
1994-01-01
Nuclear power and sustainable development
International Nuclear Information System (INIS)
In Romania, the nuclear power is an element of sustainable development, being competitive, efficient and viable in the market economy. Fuel supply is ensured as nuclear fuel is manufactured in the country out of local uranium resources available in Romania. As for the environmental protection, it is known that, unlike the thermal power plants, the nuclear power plants do not release sulfur and nitrogen oxides, carbon dioxide and do not generate slag and ashes. The operation of nuclear power units does not release pollutants and, accordingly, these stations can contribute to the limitation and the abatement of environmental pollution. After seven years of Cernavoda NPP Unit 1 operation, a facility for storing low and medium level nuclear fuel wastes was built at the plant site as well as an intermediate dry storage for spent nuclear fuel whose first modules were commissioned in July 2003. They shall ...
2003-07-01
FRAMATOME's continuous efforts to improve steam generator corrosion resistance
International Nuclear Information System (INIS)
Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam ...
Energetic analysis of fruit juice processing operations in Nigeria
Energy Technology Data Exchange (ETDEWEB)
Energy and exergy studies were conducted in an orange juice manufacturing industry in Nigeria to determine the energy consumption pattern and methods of energy optimization in the company. An adaptation of the process analysis method of energy accounting was used to evaluate the energy requirement for each of the eight defined unit operations. The types of energy used in the manufacturing of orange juice were electrical, steam and manual with the respective proportions of 18.51%, 80.91% and 0.58% of the total energy. It was estimated that an average energy intensity of 1.12 MJ/kg was required for the manufacturing of orange juice. The most energy intensive operation was identified as the pasteurizer followed by packaging unit with energy intensities of 0.932 and 0.119 MJ/kg, respectively. The exergy analysis revealed that the pasteurizer was responsible for most of the inefficiency (over 90%) followed ...
2008-01-15
Energy Technology Data Exchange (ETDEWEB)
The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate the likely results from industrial scale units which could be operated with low ...
1999-05-01
Phase 2 Final Report. IAEA Safeguards: Implementation blueprint of commercial satellite imagery
International Nuclear Information System (INIS)
This document - IAEA Safeguards: Implementation Blueprint of Commercial Satellite Imagery - constitutes the second report from SSC Satellitbild giving a structured view and solid guidelines on how to proceed with a conceivable implementation of satellite imagery to support Safeguards activities of the Agency. This Phase 2 report presents a large number of concrete recommendations regarding suggested management issues, work organisation, imagery purchasing and team building. The study has also resulted in several lists of actions and preliminary project plans with GANT schedules concerning training, hardware and software, as well as for the initial pilot studies. In both the Phase 1 and Phase 2 studies it is confirmed that the proposed concept of a relatively small Imagery Unit using high-resolution data will be a sound and feasible undertaking. Such a unit capable of performing advanced image processing as a tool for various safeguard tasks ...
1989-08-01
Experimental and theoretical studies on humidification-dehumidification-desalination
Energy Technology Data Exchange (ETDEWEB)
The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water properties within humidification and condensation towers. Therefore, the purpose of this study was to ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the dose rate in the two identified areas was 3.5 mSv y{sup -1}. The purpose of this ...
2006-02-24
Korean experience in CANDU-PHWR operation
Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work it is intended a methodology to validate a new version of the software used for monitoring the reactor core, which requires of the evaluation of the thermal limits settled down in the Operation Technical Specifications, for the Unit 2 of Laguna Verde with ARTS (improvements to the APRMs, Rod Block Monitor and Technical specifications). According to the proposed methodology, those are shown differences found in the thermal limits determined with the new versions and previous of the core monitoring software. Author)
2005-07-01
Fuel cost analysis of CANDU-PHWR Wolsung Nuclear Power Plant unit 1
International Nuclear Information System (INIS)
Being based on the Segal method, calculation was carried out for the natural uranium nuclear fuel cost with Zircaloy-4 cladding having design parameters of Wolsung Nuclear Power Plant, CANDU-PHWR (Unit 1), currently under construction in Korea aiming at its completion in 1982. An attempt was also made for the sensitivity analysis of each fuel component; i.e., depreciation of fuel manufacturing plant caused by its life time, its load factor, production scale expansion of plant facilities, variations of construction and operating costs of fuel manufacturing plant, fluctuation of interest rates, extent of uranium ore price increases and effect of learning factor. (author).
1977-01-01
Electricity generation from rice husk in Indian rice mills: potential and financial viability
Energy Technology Data Exchange (ETDEWEB)
Rice husk generated as a by-product of rice processing is an important energy resource. The availability of this resource in India has been assessed and the technologies for exploitation of its energy potential in rice processing industry discussed. Nomographs have been developed for estimation of the husk required to meet the energy demand of parboiling, drying and milling operations. The unit cost of electricity using rice husk gasifier-based power generation systems has been calculated and its financial feasibility assessed in comparison with utility-supplied and diesel-generated electricity. With the cost and efficiency data assumed here, the unit cost of electricity produced by rice husk gasifier-dual fuel engine-generator system varies between Rs 2/kWh and Rs 7/kWh. (author)
1996-10-01
Electricity generation from rice husk in Indian rice mills: potential and financial viability
Energy Technology Data Exchange (ETDEWEB)
Rice husk generated as a by-product of rice processing is an important energy resource. The availability of this resource in India has been assessed and the technologies for exploitation of its energy potential in the rice processing industry discussed. Nomographs have been developed for estimation of the husk required to meet the energy of parboiling, drying and milling operations. The unit cost of electricity using rice husk gasifier-based power generation systems has been calculated and its financial feasibility assessed in comparison with utility-supplied and diesel-generated electricity. With the cost and efficiency data assumed here, the unit cost of electricity produced by rice husk gasifier-dual fuel engine-generator system varies between Rs 2/kWh and Rs 7/kWh. (35 Rs approximates to SUS 1.). (author)
1998-12-31
Dual-fuel engine conversions evaluated by U.S. Navy
Energy Technology Data Exchange (ETDEWEB)
In seeking ways to reduce emissions from two-stroke locomotive type engines, the Navy has evaluated dual-fuel conversions operating on a compression ignition cycle, using up to 94% natural gas and 6% diesel pilot fuel. The Navy has conducted an evaluation and test program under the direction of Dr. Normnn L. Helgeson, at the Naval Facilities Engineering Service Center in Port Hueneme, California. Of the Navy`s many diesel engines, those installed in its MUSE (mobile utility support equipment) units for temporary electrical power were the first Navy off-road engines to be affected by emissions regulations. Most of the units are powered by the EMD 645 engine, and when burning diesel fuel do not meet the emission requirements in many areas of the country. This paper discusses the changes and results of the conversion and shakedown tests.
1996-10-01
Cost and sensitivity analysis for photovoltaic station in Kuwait
Energy Technology Data Exchange (ETDEWEB)
A full analysis is shown in this paper for the cost of kWh generated from photovoltaic station located in Kuwait. By using a 21 years weather data for Kuwait, the yearly generated energy was found by proposing the PV station capacity with known panels tilt angle. The cost of kWh generated from PV station was compared with the kWh generated from conventional units in the country. A sensitivity analysis was done to some factors, capital cost per installed PV peak watt, discount rate, and operating peak hours, which affect the cost of kWh production from both PV and conventional units. If the PV station is proposed to be installed in Kuwait, the capital cost per PV installed peak watt must be less than today`s prices. (author)
1996-05-01
Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4
Energy Technology Data Exchange (ETDEWEB)
The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)
1998-12-31
Coal quality engineering aids purchasing
Energy Technology Data Exchange (ETDEWEB)
New York State Electric and Gas Co. (NYSEG) has developed a tool called Coal Quality Engineering Analysis (CQEA) to evaluate the cost impacts of coal quality on its power plants. CQEA allows quantification of the effect of coal quality on plant operating costs and has become an important factor in coal purchasing. The article describes the development of the analysis method, including a logic diagram of CQEA relationships. The results of CQEA calculations on the impact of one coal on overall production costs of different units, the impact of different coals on overall production costs of one unit, and production cost vs. coal quality, are presented and discussed. The use of the CQEA system within NYSEG is described.
1987-06-01
British Nuclear Fuels PLC: report and accounts 1988-89
International Nuclear Information System (INIS)
This item covers a meeting held between members of the United Kingdom government's energy committee and representatives of British Nuclear Fuels (BNFL) to discuss their Annual Report and Accounts for the year 1988-89. The committee explored the reasons for escalating predictions of the costs of nuclear power and why decommissioning costs are so difficult to estimate accurately so as to include them in cost per kilowatt hour of generated electricity. The relationship between BNFL and the Ministry of Defence (MoD) was explored, as was the MoD's relationship with the United States Department of Defense. BNFL's financial position should improve when the thermal oxide reprocessing plant at Sellafield becomes operational, and the Chapelcross and Calder Hall reactors may contribute income from electricity generation. (UK).
Britain's dirty deeds at Maralinga
Energy Technology Data Exchange (ETDEWEB)
Following the United Kingdom's nuclear tests at Maralinga in Australia in the 1960's, the Australian government signed away its rights to claim compensation for decontamination costs in a 1968 agreement. Controversy now rages as the Australian government is claiming pound33 million for this purpose from the United Kingdom to compensate the Maralinga Tjarutja for the loss of access to their traditional lands. They claim that the UK clean-up operation was inadequate and that much plutonium was spread over the land, rather than contained in pits. Measurements of contamination at the site were wrong by a factor of ten according to a 1984 visit when Australian scientists were horrified to realize that an Aboriginal child living near Taranaki could inhale more than 460 millisieverts a year. As ministers from both countries meet in June 1993 the debate is likely to be heated and hotly defended. (UK).
1993-06-12
Application of nuclear energy for power generation at TAPS 3 and 4
International Nuclear Information System (INIS)
Tarapur Atomic Power Station, Unit 3 and 4 is located on the West Coast of the Arabian Sea near the existing Tarapur Atomic Power Station Unit 1 and 2. The nearest railway station is Boisar at a distance of 12 km from the site, which is on the main Western Railway Mumbai-Delhi route. The site is well connected by road and is about 30 Km from Mumbai-Ahmedabad National Highway-NH-8. The paper describes the land acquisition and rehabilitisation of the affected families, importance of project in the western grid, how it works, working principles of PHWR, principle of operation, major components/equipment, important systems, safety features, and waste management
2010-10-01
ASPEN simulation of environmental control processes: Final report
Energy Technology Data Exchange (ETDEWEB)
The United States Department of Energy (DOE) at the Morgantown Energy Technology Center (METC) contracted with P.S. Lowell and Co. Inc. (Lowell and Co.) and Jay S. Dweck, Consultant, Inc., (JSD) to enhance the capability of ASPEN in simulating coal gasification and oil shale processing plants. Of particular concern was the capability to predict the distribution of environmentally significant components among the various aqueous and organic liquids and gas streams within or leaving the process. The project was divided into major task areas. The first was to develop and implement the calculational routines necessary for predicting aqueous electrolyte chemical reactions. Part of this effort also was to select a species list and collect and/or regress data for the necessary parameters. The second task was to develop and implement a multi-phase flash capability (including precipitated solids) and unit operations models for a ...
1988-04-01
The operating experience for Wolsung Unit 3 commissioning
International Nuclear Information System (INIS)
This is a slide-based oral presentation given to the COG/IAEA: Fifth technical committee meeting on 'Exchange of operating experience of pressurized heavy water reactors' held in Mangalia, Romania on 7-10 September 1998. Since energization of Wolsung Unit 3 station service transformer on July 12, 1996 a line of initial test program was conducted as follows: 1. ILRT/SIT; 2. Pre-operational and Hot Functional testing with a Light Water and without Fuel in Systems; 3. Load D_2O in Moderator System; 4. Initial fuel loading; 5. Load D_2O in PHT System; 6. Hot Functional Testing with Heavy Water and Fuel in Systems; 7. Criticality and Low Power Physics Testing; 8. Power Ascension Test and, then finally, phase-D test; the plant acceptance test was accomplished after having a Mini-Overhaul to prepare for Commercial Operation. These documents contain not only both overall introduction of commissioning and the ...
1998-09-07
Energy Technology Data Exchange (ETDEWEB)
With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the result of the model calculation, anomaly detection may be found ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its technical practicability, ...
1995-02-01
Spent Fuel Transfer to Dry Storage Using Unattended Monitoring System
Energy Technology Data Exchange (ETDEWEB)
There are 4 CANDU reactors at Wolsung site together with a spent fuel dry storage associated with unit 1. These CANDU reactors, classified as On-Load Reactor (OLR) for Safeguards application, change 16- 24 fuel bundles with fresh fuel in everyday. Especially, the spent fuel bundles are transferred from spent fuel bays to dry storage throughout a year because of the insufficient capacity of spent fuel pond. Safeguards inspectors verify the spent fuel transfer to meet safeguards purposes according to the safeguards criteria by means of inspector's presence during the transfer campaign. For the verification, 60-80 person-days of inspection (PDIs) are needed during approximately 3 months for each unit. In order to reduce the inspection effort and operators' burden, an Unattended Monitoring System (UMS) was designed and developed by the IAEA for the verification of spent fuel bundles transfers from wet storage ...
2009-05-15
Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant
International Nuclear Information System (INIS)
This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and maximum ...
1987-01-01
Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and ...
1987-09-01
Pilot-scale testing of pyrolysis for the volume reduction of organic waste
Energy Technology Data Exchange (ETDEWEB)
Pilot-scale pyrolysis units have been in operation since 1980 to test the efficiency of thermal treatment of transuranic (TRU) solid waste to retrieve the TRUs and to reduce the volume of wastes such as spent solvent, spent resin, and others. These wastes are generated by reprocessing, fuel production, and utilities. NUKEM has developed a criticality-safe, ring-slab reactor to decompose solid TRU waste. The plant processes 25 kg/h with a polyvinyl chloride content up to 70%. The overall throughput (inactive) up to the spring of 1982 was 2000 kg. The decontamination factor for the reactor itself is 1000. The liquid wastes, mainly spent solvent, are cracked under nitrogen at 400 to 700/sup 0/C in a reactor that is filled by a packed bed kept in motion by a specially designed agitator. This unit was built for 15 kg/h water equivalent evaporation. Up to 1982 the unit processed 2000 kg of spent solvent ...
1982-11-01
Pilot-scale testing of pyrolysis for the volume reduction of organic waste
International Nuclear Information System (INIS)
Pilot-scale pyrolysis units have been in operation since 1980 to test the efficiency of thermal treatment of transuranic (TRU) solid waste to retrieve the TRUs and to reduce the volume of wastes such as spent solvent, spent resin, and others. These wastes are generated by reprocessing, fuel production, and utilities. NUKEM has developed a criticality-safe, ring-slab reactor to decompose solid TRU waste. The plant processes 25 kg/h with a polyvinyl chloride content up to 70%. The overall throughput (inactive) up to the spring of 1982 was 2000 kg. The decontamination factor for the reactor itself is 1000. The liquid wastes, mainly spent solvent, are cracked under nitrogen at 400 to 700"0C in a reactor that is filled by a packed bed kept in motion by a specially designed agitator. This unit was built for 15 kg/h water equivalent evaporation. Up to 1982 the unit processed 2000 kg of spent solvent ...
New era for coal-based electricity generation in the United States
Energy Technology Data Exchange (ETDEWEB)
In 1970, the Federal Power Commission predicted a fall from 46% to 27% in 1990 as a result of predicted increases in the use of nuclear power. Today, the Department of Energy expects coal to supply about 50% of electricity generation in 1990. About one-eighth of the world's annual hard coal production is used to make electricity in the United States. Power stations in the country used more coal in 1979 than was produced in the whole Western Europe that year. These 405,000,000 tons of coal equivalent were burned in 1257 individual utilities with an aggregate capacity of 235,000 megawatts. There are coal-fired power plants in 43 of the 50 states. Four factors will be most important in shaping the future development of coal-based electricity: prices, conservation, environmental regulations, and national security. The price differential between coal and oil has now reached a level where it is much more economic for a United States electric ...
1980-01-01
International water power and dam construction handbook
Energy Technology Data Exchange (ETDEWEB)
The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; details of turbine and ...
1992-01-01
Direct energy conversion for IEC fusion for space applications
Energy Technology Data Exchange (ETDEWEB)
The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It ...
2000-08-01
Energy Technology Data Exchange (ETDEWEB)
After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill inspection and manipulation requirements were ...
1994-12-31
Wind turbulence estimates in a valley by coherent Doppler lidar
British Library Electronic Table of Contents (United Kingdom)
Abstract In this paper, the effect of several turbulence parameters during various flow conditions in Owens Valley, educed from coherent Doppler lidar data have been studied. Radial velocity structure functions are processed to estimate the turbulent kinetic energy (TKE) dissipation rate, integral length scale and velocity variance, assuming a theoretical model for isotropic wind fields. Corrections for turbulence measurements have been considered to address the complications due to inherent volumetric averaging of radial velocity over each range gate, noise of the lidar data, and the assumptions required to estimate effects of smaller scales of motion on turbulence quantities. Using data from the Terrain-induced Rotor Experiment (T-REX) in April-May 2006, vertical profiles of wind and tur...
2011-01-01
Thermo-economic analysis of solar powered adsorption heat pump
British Library Electronic Table of Contents (United Kingdom)
The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...
2007-01-01
List of Local Government Area (LGA) names - NPI
...Albury NSW Armidale Dumaresq NSW Ashfield NSW Auburn NSW Ballina NSW Balranald NSW Bankstown NSW Bathurst Regional NSW Baulkham Hills NSW Bega Valley NSW Bellingen NSW Berrigan NSW Blacktown NSW Bland NSW Blayney NSW Blue Mountains NSW Bogan NSW Bombala NSW Boorowa NSW Botany Bay NSW Bourke NSW Brewarrina NSW Broken Hill NSW Burwood NSW Byron NSW Cabonne NSW Camden NSW Campbelltown NSW Canada Bay NSW Canterbury NSW Carrathool NSW Central Darling NSW Cessnock NSW Clarence Valley NSW Cobar NSW Coffs Harbour NSW Conargo NSW Coolamon NSW Cooma-Monaro NSW Coonamble NSW Cootamundra NSW Corowa NSW Cowra ...
Landscapes are both a synthesis and an expression of national, regional and local cultural heritages. It is therefore very important to develop techniques aimed at cataloguing and archiving their forms. This paper discusses the LDL (Landscape Digital Library) project, a Web accessible database that can present the landscapes of a territory with documentary evidence in a new format and from a new perspective. The method was tested in a case study area of the river Po valley (Northern Italy). The LDL is based on a collection of photographs taken following a systematic grid of survey points identified through topographic cartography; the camera level is that of the human eye. This methodology leads to an innovative landscape archive that differs from surveys carried out through aerial photographs or campaigns aimed at selecting "relevant" points of interest. Further developments and possible uses of the LDL are also discussed.
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
A three-component seismic line acquired over the Zamora gas field, northern Sacramento Valley, California, displays conventional (P-P) and converted-wave (P-SV) seismic anomalies. Well log and seismic modeling results indicate that bright-spot reflection strengths are related to variations in fluid saturation and lithology. The P-SV reflection strengths and interval velocities provide valuable information that complements more conventional strategies such as amplitude with offset and polarity analysis. This integrated strategy can improve risk evaluation and well-site selection in areas where rapid changes in reservoir quality impact resource evaluation.
1989-03-01
Energy Technology Data Exchange (ETDEWEB)
A three-component seismic line acquired over the Zamora gas field, northern Sacramento Valley, California, displays conventional (P-P) and converted-wave (P-SV) seismic anomalies. Well log and seismic modeling results indicate that bright-spot reflection strengths are related to variations in fluid saturation and lithology. The converted-wave reflection strengths and interval velocities provide valuable information that compliments more conventional strategies such as amplitude with offset and polarity analysis. This integrated strategy can improve risk evaluation and well site selection in areas where rapid changes in reservoir quality impact resource evaluation.
1989-04-01
Concentration of Melton Valley Storage Tank surrogates with a wiped film evaporator
Energy Technology Data Exchange (ETDEWEB)
This report describes experiments to determine whether a wiped film evaporator (WFE) might be used to concentrate low-level liquid radioactive waste (LLLW). Solutions used in these studies were surrogates that contain no radionuclides. The compositions of the surrogates were based on one of Oak Ridge National Laboratory`s (ORNL`s) Melton Valley Storage Tanks (MVSTs). It was found that a WFE could be used to concentrate LLLW to varying degrees by manipulating various parameters. The parameters studied were rotor speed, process fluid feed temperature and feed rate, and evaporator temperature. Product consistency varied from an unsaturated liquid to a dry powder. Volume reductions up to 68% were achieved. System decontamination factors were consistently in the range of 10{sup 4}.
1994-08-01
Seismic stratigraphy based chronostratigraphic (SSBC) analysis of the Serbian Banat region allows the delineation of the spatial and stratigraphic relationships of the generally regressive and shallowing upward Neogene depositional fill of a tectonically unstable central portion of the Pannonian Basin. When geometrically restored in time and space, the sediment dispersal directions, sediment source directions, types of sedimentation breaks and the tectonic events influencing basin evolution can be delineated. For such an analysis the time-transgressive lithostratigraphic units used in the neighbouring Hungarian part of the Pannonian Basin are conveniently introduced based upon their characteristic seismic facies and constrained borehole log records as mappable seismic stratigraphic sequence units, termed "seismic operational sequences". The respective Neogene stage and operational sequence equivalents ...
2010-12-01
International Nuclear Information System (INIS)
The main goal of this paper is to present a methodology for calculating the radioactivity in the moderator and heat transport systems of Cernavoda NPP Unit 1, with the intention to improve the knowledge on the radionuclides inventories in the operational waste streams, and to aid the licensing process of new near surface repository. In the present paper we describe our methodology for estimating H-3 and C-14 production rates in the heavy-water moderator and heat transport systems using the capacity factors from 1997 to 2007 years. The radioactivity of the difficult-to-measure nuclides is predicted by scaling method using measured concentration in reference CANDU 6 reactor Gentilly-2. The difficult-to-measure radionuclides of primary interest in this study were those with long half-lives which have a significant role for post-closure safety assessment. The equation used to scale fission products (parents and daughters) is based on the ...
2009-05-27
Energy Technology Data Exchange (ETDEWEB)
This decision document presents the selected remedial action for the Ruston/North Tacoma Study Area, in Ruston and Tacoma, Washington. The EPA has divided the Commencement Bay/Nearshore Tideflats Superfund site into seven operable units (OU's) in order to facilitate the investigation, analysis, and cleanup of this very large site. Four of these OU's are associated with the Asarco smelter: OU 02 - Asarco Tacoma Smelter; OU 04 - Asarco Off-Property (Ruston/North Tacoma Study Area); OU 06 - Asarco Sediments; and OU 07 - Asarco Demolition. The remedy described in this ROD addresses OU 04 and involves the cleanup of arsenic and lead contaminated soils and slag in the Study Area, the residential community surrounding the smelter. This remedy will address the principal threat posed by conditions at the site, which is the ingestion of contaminated soil and dust.
1993-06-01
Innovative coke oven gas cleaning system for retrofit applications. Volume 1, Public design report
Energy Technology Data Exchange (ETDEWEB)
This Public Design Report provides, in a single document, available nonproprietary design -information for the ``Innovative Coke Oven Gas Cleaning System for Retrofit Applications`` Demonstration Project at Bethlehem Steel Corporation`s Sparrows Point, Maryland coke oven by-product facilities. This project demonstrates, for the first time in the United States, the feasibility of integrating four commercially available technologies (processes) for cleaning coke oven gas. The four technologies are: Secondary Gas Cooling, Hydrogen Sulfide and Ammonia Removal, Hydrogen Sulfide and Ammonia Recovery, and Ammonia Destruction and Sulfur Recovery. In addition to the design aspects, the history of the project and the role of the US Department of,Energy are briefly discussed. Actual plant capital and projected operating costs are also presented. An overview of the integration (retrofit) of the processes into the existing plant is presented and is followed ...
1994-05-24
Energy Technology Data Exchange (ETDEWEB)
In the preparing stage of Final Safety Analysis Report (FSAR), the expected inventories of radwaste treatment systems are estimated. The inventory calculation plays an important role in the estimation of environmental radiation as well as nuclear power plant (hereafter referred to NPP) integrity, and further improvement of the public perception for NPP or radiation. The inventory has been accumulated and periodically measured for every NPP during the whole operation in Korea. But, a detailed analysis and database construction for the inventory have not still been carried out. For estimating the inventory change in this study, the radwaste treatment systems of Wolsung (hereafter referred to WS) nuclear power units 3 and 4 were selected as the reference systems. An analysis and prediction of the inventory change were performed for total activity released to environment during the whole operation. The linear regression ...
2006-07-01
International Nuclear Information System (INIS)
In the preparing stage of Final Safety Analysis Report (FSAR), the expected inventories of radwaste treatment systems are estimated. The inventory calculation plays an important role in the estimation of environmental radiation as well as nuclear power plant (hereafter referred to NPP) integrity, and further improvement of the public perception for NPP or radiation. The inventory has been accumulated and periodically measured for every NPP during the whole operation in Korea. But, a detailed analysis and database construction for the inventory have not still been carried out. For estimating the inventory change in this study, the radwaste treatment systems of Wolsung (hereafter referred to WS) nuclear power units 3 and 4 were selected as the reference systems. An analysis and prediction of the inventory change were performed for total activity released to environment during the whole operation. The linear regression ...
2006-11-02
Fracture characterizatioin of the Bandelier tuff in OU-1098 (TA-2 and TA-41)
Energy Technology Data Exchange (ETDEWEB)
Rock fracture characterization documents a total of 1496 fractures in unit 2 of the Tshirege Member of the Bandelier Tuff along 6013 feet of Los Alamos Canyon`s north wall adjacent to Operational Unit 1098. Geologically termed joints, these fractures likely owe their primary origin to brittle failure during the cooling contraction of the tuff after its emplacement nearly 1 million years ago. Subsequent tectonic movement along the Pajarito Fault system has modified fracture strikes, dips, apertures, and linear density. From a background linear density of approximately 20 fractures per 100-foot interval along the canyon wall, fracture density increases to values in excess of 50 fractures per 100-foot interval in a zone at and immediately east of the Omega West reactor building TA-2-1. This increase in fracture density is coincident with the mapped trace of the Guaje Mountain Fault (GMFZ) that apparently bifurcates with a ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Organic Rankine cycles (ORC) have unique properties that are well suited to solar power generation. In this work design and performance calculations are performed using MatLab/SimuLink computational environment. The cycle consists of thermal solar collectors (Flat Plate Solar Collector (FPC), or Parabolic Trough Collector (PTC), or Compound Parabolic Concentrator (CPC)) for heat input, expansion turbine for work output, condenser unit for heat rejection, pump unit, and Reverse Osmosis (RO) unit. Reverse osmosis unit specifications used in this work is based on Sharm El-Shiekh RO desalination plant. Different working fluids such as: butane, isobutane, propane, R134a, R152a, R245ca, and R245fa are examined for FPC. R113, R123, hexane, and pentane are investigated for CPC. Dodecane, nonane, octane, and toluene are allocated for PTC. The proposed process units are modeled and show a ...
2010-11-15
United States Air Force Academy (USAFA) Vertical Axis Wind Turbine. Final report May 77-Sep 80
This report describes the design, fabrication, installation and testing of a small variable-speed vertical axis wind turbine (VAWT). This VAWT is unique in its installation using hand tools only; unconventional and simple support system; and variable speed operation under microprocessor control. Initial testing confirmed that the turbine can be controlled by commanded alternator field modulation. Further studies will be directed toward determination of an optimum control algorithm.
1980-09-01
Energy Technology Data Exchange (ETDEWEB)
The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)
2001-07-01
Semantic network array processor and its applications to image understanding
Energy Technology Data Exchange (ETDEWEB)
The problems in computer vision range from edge detection and segmentation at the lowest level to the problem of cognition at the highest level. This correspondence describes the organization and operation of a semantic network array processor (SNAP) as applicable to high level computer vision problems. The architecture consists of an array of identical cells each containing a content addressable memory, microprogram control, and a communication unit. The applications discussed in this paper are the two general techniques, discrete relaxation and dynamic programming. While the discrete relaxation is discussed with reference to scene labeling and edge interpretation, the dynamic programming is tuned for stereo.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).
1989-09-01
International Nuclear Information System (INIS)
Technologic regimes of cryomotor rotor fabrication are determined. Blanks of yttrium ceramics powder are molded hydrostatically at 400-600 MPa. To confirm the serviceability of electric machines of the considered, a hysteretic 10 W power electric motor with the following dimensions of HTSC-ceramics rotor: external diameter - 56 mm; internal diameter - 45 mm, height - 60 mm, is developed and tested in the liquid nitrogen medium. 8 refs.; 8 figs.; 1 tab.
1995-01-01
Leak detection on petroleum pipelines
Energy Technology Data Exchange (ETDEWEB)
This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.
1984-04-01
How Waste Management Can Be Influenced By Transport Packagings
With major D&D projects ongoing or being planned, and also with the daily management of radwaste from nuclear facilities, the potential role of transport packagings has often been overlooked: here will one rely essentially on drums, there several local waste processing units are built, elsewhere decommissioned facilities are cut in small bits to fit into small containers by far less efficient. The present paper proposes to illustrate how integrating a transport system from the start may influence operational choices of waste management.
2002-02-28
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Experimental studies on non-parabolic asymmetrical solar concentrators with evacuated receivers
Energy Technology Data Exchange (ETDEWEB)
Asymmetrical solar concentrators may offer significant advantages over symmetrical ones by the higher yearly average energy input per unit aperture area and the wider range of flexibilities in the design and operation. This paper describes the design, construction and performance evaluation of a non-parabolic asymmetrical solar concentrator with an evacuated receiver. The concentrator has a concentration ratio of 3.25 and a theoretical optical efficiency of 0.67. Collector efficiency test results are presented and compared with another similar concentrator without an evacuated receiver.
1983-06-01
International Nuclear Information System (INIS)
The sensitivity of the primary circuit material was examined at the Mochovce and Dukovany NPPs. No significant sensitivity of the base material or the weld metal to the initiation of corrosion cracking was observed. Thermal aging was found to accelerate significantly the corrosion fatigue kinetics in the material of the heat affected zone. The threshold values of the double amplitudes of the stress intensity factor were below 8 MPa/m"2 for the materials examined, with a cycle asymmetry coefficient of 0.65. The tests revealed no appreciable sensitivity to general corrosion, pitting, or intergranular corrosion. (J.B.). 7 tabs., 26 figs., 11 refs.
Dynamics of a reverse osmosis unit with application to pulsating regimes for process optimization
British Library Electronic Table of Contents (United Kingdom)
We propose unsteady-state reverse osmosis cell modelling in two dimensions. The convection-diffusion equation describing the concentration of the relevant chemical species is solved by a finite difference technique, while the velocity field is described by empirical expressions for spiral-wound membrane cells. A non-constant permeability is introduced to take into account the effects of membrane compaction at high operating pressures. The role of concentration polarization is discussed for different values of the parameters describing the global process. Finally, the model is applied to predict the effects of a pulsating flow where a cyclic pressure feed is adopted to enhance the permeate flux. In this context, an experimental validation of the model is proposed.
2011-01-01
This report covers the first year of operation of a fuel cell power plant, installed by PPL Spectrum, Inc. (PPL) under contract with the United States Coast Guard (USCG), Research and Development Center (RDC). The fuel cell was installed at Air Station Cape Cod in Bourne, MA. The project had the support of the Massachusetts Technology Collaborative (MTC), the Department of Energy (DOE), and Keyspan Energy. PPL selected FuelCell Energy, Inc. (FCE) and its fuel cell model DFC{reg_sign}300 for the contract. Grant contributions were finalized and a contract between PPL and the USCG for the manufacture, installation, and first year's maintenance of the fuel cell was executed on September 24, 2001. As the prime contractor, PPL was responsible for all facets of the project. All the work was completed by PPL through various subcontracts, including the primary subcontract with FCE for the manufacture, delivery, and installation of the fuel ...
2004-06-30
Bring fresh ideas to boiler startup procedures
Energy Technology Data Exchange (ETDEWEB)
This article describes innovations in new-boiler startups, based on experiences at United Development Group`s 50-MW Niagra cogeneration facility, Niagra Falls, NY. The plant comprises: a circulating coal fluidized bed boiler supplying steam to a nearby factory and electricity to the grid. Before operation the system was flushed with demineralized water, and the boiler degreased, the steam blow relied on a new procedure involving a continuous flow of steam. Startup was then initiated, following manufacturers heatup rate and soak times closely. After startup boiler tube sections were checked, and cleaned if necessary. 1 fig.
1996-05-01
Behavior of hydrogen at coal liquefaction of NEDOL process
Energy Technology Data Exchange (ETDEWEB)
There are many reports concerning the behavior of hydrogen at coal liquefaction. However, all of them are the results by autoclave batch tests, and there are few reports discussing results of continuous coal liquefaction tests in long term operation. Coal liquefaction tests were conducted on Wandoan, Illinois No. 6, Wyoming and Tanito Harum coal at the NEDOL Process 1t/d Process Supporting Unit (PSU), and the behavior of hydrogen and deheterogeneity at coal liquefaction were investigated. Furthermore, the effect of fa (fraction of aromatic) of recycle solvent on the behavior of hydrogen was also studied.
1995-12-31
An algorithm for scheduling a large pumped storage plant
Energy Technology Data Exchange (ETDEWEB)
The Michigan Electric Coordination Center (MEPCC), operated by Consumers Power and Detroit Edison Companies, has the responsibility for scheduling the Ludington pumped storage plant. Ludington has an extremely large economic effect on the Consumers Power and Detroit Edison Companies' system due to its size (over 1800 MW net demonstrated generating capability). This paper presents a dynamic programming algorithm for scheduling large pumped storage plants and shows how this method can be coordinated with the commitment of the thermal units of the system.
1985-08-01
System, economy and ecology viewpoints of the Krsko NPP lifetime extension
International Nuclear Information System (INIS)
Krsko NPP plant life extension was analysed and evaluated with respect to system, economy and ecology viewpoints. From the system perspective it was established that also in the extended lifetime the plant will remain in operation as a base load electricity supplier. The systematic review was performed to determine its overall competitiveness against advanced coal, gas and new nuclear units. The analysis considered also hydro and renewable sources. Analysis and evaluations resulted in the conclusion that the Krsko NPP lifetime extension is the most effective alternative for base load production due to small additional capital investments, low fuel costs, no new siting requirements, lowest climate and environmental impact, and reliable and safe operation. (author)
2007-09-10
Energy Technology Data Exchange (ETDEWEB)
Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES systems studied do not contribute to ...
1992-09-01
Summary of research on microbiological processes
Energy Technology Data Exchange (ETDEWEB)
Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES systems studied do not contribute to ...
1992-09-01
Energy Technology Data Exchange (ETDEWEB)
The paper presents a procedure for the calculation of an absorption-refrigeration plant that uses an LiBr/ZnBr{sub 2}/CH{sub 3}OH solution and is driven throughout the year by heat received from a solar pond. The calculations for the solar pond are based on a finite-difference solution of the transient heat conduction differential equation during the year, and the operation of the refrigeration unit is simulated by the use of functions describing the thermodynamic behaviour of the working medium. On the basis of the procedure devised, correlations and nomographs are developed that describe the seasonally optimum operation of the proposed composite system. The nomographs may be employed for a first estimation in the design of such systems. (Author).
1992-07-01
Liquid metal reactor cover gas purification and analysis in the USA
International Nuclear Information System (INIS)
Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.
1986-09-24
The United States deployed 118 military working dogs (MWDs) to the Persian Gulf theater during Operations Desert Shield and Desert Storm. This study is a retrospective descriptive study of medical records of these deployed dogs, with the objective to determine whether there were infectious or parasitic diseases with a zoonotic potential in a sentinel population of MWDs that may be of concern to Persian Gulf veterans. Fifty-one percent of visits to veterinary treatment facilities during deployment were for illness or injury. Potential zoonotic conditions accounted for 21% of the total visits, 41% of the "sick-call" visits, and 63% of presentations for illness to veterinary treatment facilities. This study did not determine whether the diseases treated were transmitted between MWDs and the troops. Although the etiologic agents were not determined in these cases, no evidence was found supporting new or reemerging illnesses in this population of ...
2001-02-01
Failure analyses and weld repair of boiler feed water pumps
Energy Technology Data Exchange (ETDEWEB)
During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.
1998-12-31
Experimental study on display-control stereotype and development of human factors guidelines
Energy Technology Data Exchange (ETDEWEB)
It is very important to develop the design guidelines which can be applicable for Korean operators for the purpose of designing the KSNP more safely. The objective of this project is to provide the standards, guidelines and bases applicable for HF-010 through the within-subject experiment for obtaining Korean operators' population stereotype for direction-of-movement of controls associated with displays on the control panels. Through the survey of researches on display compatibility and the classification of types of displays and controls in the main control room of Uljin units 3 and 4, methods for an experiment on the stereotype were established. Experimental interface prototypes for a total of 108 combinations of display and control types were implemented. Experimental data collection and analysis system was built in association with the interface prototypes. The experiment was performed with participation of 250 ...
2003-01-01
Evaluation of chips quality by the analysis of two different harvesting methodologies
Energy Technology Data Exchange (ETDEWEB)
The Council for Research in Agriculture, Agricultural Engineering Research Unit (CRA-ING) in Rome, Italy has developed an innovative short-rotation forestry (SRF) harvesting system. The system involves a 2 step operation, notably the tree felling and inter-row windrowing performed by a feller windrower equipment; and subsequent chipping performed by a harvester equipped with a pick-up device. The low moisture content of the windrowed trees at harvesting time affects their physical qualities and mechanical strength throughout the chipping operation. The purpose of this study was to analyze the moisture losses of windrowed trees, in relation to the windrow location, on field storage and weather condition. In addition, the study characterized chips quality changes during on field storage by the 2 different harvesting systems. The innovative 2-step system was compared with the traditional 1-step harvesting system.
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
Operation and maintenance cost estimating methodologies for advanced coal-fired atmospheric circulating fluidized-bed and advanced natural gas-fired combined cycle electric power plants are presented. The purpose of these cost estimating relationships is for use in long range planning and evaluation of the economics of use of these technologies for electric power generation. Projected annual costs of reference plants at ten different sites in the United States, one in each of the ten DOE regions, are given as of 1989, and comparisons are made with existing technologies. A listing of a computer program implementing the methodologies is included. 14 refs., 4 figs., 13 tabs.
1989-12-01
International Nuclear Information System (INIS)
TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)
2006-11-13
British Library Electronic Table of Contents (United Kingdom)
In a previous paper, the performance of the humidification?dehumidification (HD) desalination process was optimized through mathematical programming. In this paper, by adding a solar system to the model, the total solar HD system is optimized. The main purpose of this optimization is the reduction of fresh water production costs. By using special operational and geographical constraints the model can be used for any region to determine optimum operation point of system. Results show that solution obtained by cost objective function has a cost 7?28% lower than other objective functions. Also recycling, in spite of the increase of productivity and decrease of specific thermal energy consumption of the HD process, increases the cost of production.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Hydrate addition at low temperature (or the HALT process) is a retrofit option for moderate SO/sub 2/ removal efficiency in coal burning utility plants. This dry FGD process involves injecting calcium based dry hydrate particles into flue gas ducting downstream of the air preheater where the flue gas temperature is typically in the range of 280-325/degree/F. This report is comprised of the conceptual scaleup design of the HALT process to a 180 MW and a 500 MW coal fired utility station followed by detailed capital and operating cost estimates. A cost sensitivity analysis of major process variables for the 500 MW unit is also included. 1 fig.
1988-12-01
CHEMICAL TECHNOLOGY DIVISION. UNIT OPERATIONS SECTION MONTHLY PROGRESS REPORT, FEBRURARY 1963
Development of a shear and leach complex for UO/sub 2/-SS clad fuel was continued with major emphasis on the operation of a rotary drum leacher. Flooding data for nozzle plate pulse columns at high A/O ratios are reported. Engineering tests of dissolution of Zr--6% U alloy with HF in molten salt demonstrated a dissolution rate of 0.8 to 1.5 mg/cm/sup 2//min. Subsequent fluorination with 100% F/sub 2/ proceeded at half times of 40 to 135 min. The results of a high level waste calcination (run R-72) made with formaldehyde treated simulated Purex waste are reported. (auth)
1963-10-01
Assessment of effects of Fort St. Vrain HTGR primary coolant on Alloy 800. Final report
Energy Technology Data Exchange (ETDEWEB)
A comprehensive review was conducted of primary helium coolant chemistry data, based on current and past operating histories of helium-cooled, high-temperature reactors (HTGRs), including the Fort St. Vrain (FSV) HTGR. A reference observed FSV reactor coolant environment was identified. Further, a slightly drier expected FSV coolant chemistry was predicted for reactor operation at 100% of full power. The expected environment was compared with helium test environments used in the US, United Kingdom, Germany, France, and Japan. Based on a comprehensive review and analysis of mechanical property data reported for Alloy 800 tested in controlled-impurity helium environments (and in air when appropriate for comparison), an assessment was made of the effect of FSV expected helium chemistry on material properties of alloy 800, with emphasis on design properties of the Alloy 800 material utilized in the FSV steam generators.
1982-08-01
Assessment of effects of Fort St. Vrain HTGR primary coolant on Alloy 800. Final report
International Nuclear Information System (INIS)
A comprehensive review was conducted of primary helium coolant chemistry data, based on current and past operating histories of helium-cooled, high-temperature reactors (HTGRs), including the Fort St. Vrain (FSV) HTGR. A reference observed FSV reactor coolant environment was identified. Further, a slightly drier expected FSV coolant chemistry was predicted for reactor operation at 100% of full power. The expected environment was compared with helium test environments used in the US, United Kingdom, Germany, France, and Japan. Based on a comprehensive review and analysis of mechanical property data reported for Alloy 800 tested in controlled-impurity helium environments (and in air when appropriate for comparison), an assessment was made of the effect of FSV expected helium chemistry on material properties of alloy 800, with emphasis on design properties of the Alloy 800 material utilized in the FSV steam generators.
Adaptive power-system stabilizer based on turbine governor control
Energy Technology Data Exchange (ETDEWEB)
A novel adaptive stabilizer, called an Adaptive Governor Power System Stabilizer (AGPSS), which operated on the governor turbine system, was described. There has been extensive research on adaptive excitation control of generators in power systems with the goal of achieving better dynamic performance. AGPSS tracks the frequency and damping of oscillations in a power system, and adjusts to ensure that there is always sufficient damping in the system. There is no interaction between stabilizers on different generating units, and each one acts independently, consuming oscillation energy locally. These stabilizers are easy to design and this facilitates their use in multimachine systems. Results obtained by nonlinear simulation of a single-machine and a three-machine power system were discussed, illustrating the effectiveness of the stabilizers in supplying damping and improving stability. It was pointed out that the operation ...
1994-12-31
European Space Agency announces contest to "Name the Cluster Quartet"
1. Contest rules The European Space Agency (ESA) is launching a public competition to find the most suitable names for its four Cluster II space weather satellites. The quartet, which are currently known as flight models 5, 6, 7 and 8, are scheduled for launch from Baikonur Space Centre in Kazakhstan in June and July 2000. Professor Roger Bonnet, ESA Director of Science Programme, announced the competition for the first time to the European Delegations on the occasion of the Science Programme Committee (SPC) meeting held in Paris on 21-22 February 2000. The competition is open to people of all the ESA member states (*). Each entry should include a set of FOUR names (places, people, or things from history, mythology, or fiction, but NOT living persons). Contestants should also describe in a few sentences why their chosen names would be appropriate for the four Cluster II satellites. The winners will be those which are considered most suitable and relevant for the Cluster II mission. ...
2000-02-01
Simulator training and licensing examination for nuclear power station operator
International Nuclear Information System (INIS)
For the recruitment, training and position qualification of the simulator instructors and feedback of training effect, the management approaches are formulated in 'The System for Simulator Training and Licensing Examination of Daya Bay Nuclear Power Station Operators'. The concrete requirements on the professional knowledge, work experience and foreign language ability of a simulator instructor are put forward. The process of instructor training is designed. The training items include the trainer training, pedagogy training, time management training, operation activities training during outage of unit, 'shadow' training and on-the-jot training on simulator courses. Job rotation is realized between simulator instructor and licensing personnel on site. New simulator instructor must pass the qualification identification. After a duration of 2 years, re-qualification has to be carried out. On the basis of the ...
2007-08-01
Methods for the simulation of the operation, in one future year, of a fixed plant mix
Energy Technology Data Exchange (ETDEWEB)
Compares methods used at CEGB (UK), EdF (France), and ENEL (Italy) for generation planning studies with particular reference to those tools (or parts of them) that perform a yearly simulation of the generating system operation. Offers a short description of the composition of the 3 generating systems for a better understanding of the different philosophies employed. Comments on the frequency of utilization of the programs and on their main differences. Suggests that since the 3 systems show a tendency towards a more similar mix in the future (e.g. the percentage of hydro power plants will decrease both in the French and in the Italian system while the nuclear and coal base units will increase; all 3 systems will include an increasing share of pumped storage plants) the discussed planning problems will probably become common to the 3 systems. Predicts increasing importance of coal transportation problems for ENEL and EdF organization; a more ...
1982-12-01
Energy Technology Data Exchange (ETDEWEB)
Automated, variable volume unloaders provide the ability to smoothly load/unload reciprocating compressors to maintain ideal operations in ever-changing environments. Potential advantages provided by this load control system include: maximizing unit capacity, optimizing power economy, maintaining low exhaust emissions, and maintaining process suction and discharge pressures. Obstacles foreseen include: reliability, stability, serviceability and automation integration. Results desired include: increased productivity for the compressor and its operators, increased up time, and more stable process control. This presentation covers: system design features with descriptions of how different types of the devices were developed, initial test data, and how they can be effectively operated; three actual-case studies detailing the reasons why automated, hydraulically controlled, variable volume, head-end ...
2003-07-01
Development of Nuclear Materials and Degradation Database
International Nuclear Information System (INIS)
There are about 440 operating nuclear power reactors in the world including 20 units from Korea. The average age of the reactors is more than 20 years and many of them are approaching to their original 30 or 40 years licensing terms. Even though some failures were reported in components or pipes of nuclear power plants (NPPs), these NPPs are considered to be too valuable to stop their operation at the end of design life. Therefore, the long-term operation of NPPs has become a worldwide trend based on technical and economic consideration. In order to ensure safe long-term operation of NPPs, it is increasingly necessary to adopt new approaches to deal with nuclear materials aging and degradation. Proactive Material Degradation Assessment (PMDA) is one of the key elements of these new approaches. Many kinds of background information such as materials and degradation history of ...
2010-10-01
Phase report 1C, TA-21 operable unit RCRA Facility Investigation, Outfalls Investigation
Energy Technology Data Exchange (ETDEWEB)
This phase report summarizes the results of field investigations conducted in 1992 at Technical Area 21 of Los Alamos National Laboratory, as prescribed by the RCRA Facility Investigation work plan for the Technical Area 21 operable unit (also known as OU 1106). This phase report is the last part of a three-part phase report describing the results of field work conducted in 1992 at this operable unit. Phase Report lA, issued on l4 June l993, summarized site geologic characterization activities. Phase report 1B, issued on 28 January 1994, included an assessment of site-wide surface soil background, airborne emissions deposition, and contamination in the locations of two former air filtration buildings. The investigations assessed in Phase Report 1C include field radiation surveys and surface and near-surface sampling to characterize potential contamination at 25 outfalls and septic systems listed as ...
1994-02-28
Studies of the dissolution of geothermal scale
Samples of geothermal scale formed from Magmamax No. 1 and Woolsey No. 1 wells in the Imperial Valley, Calif., were exposed to concentrated and dilute solutions of common laboratory reagents. The time of exposure and temperature of the reagent were also varied. Several reagents easily dissolved significant amounts of the scale. An in situ test was performed with marginal success.
1980-02-04
Energy Technology Data Exchange (ETDEWEB)
The spatial connection between the zones of deep-lying faults and the narrowly-localized paleo-relief sections posessing an anomolous sedimentation condition in the latter Cretaceous is identified. It is established that this is of significance in choosing the primary regions for conducting oil exploration.
1980-01-01
... The moorland landscape looks especially colourful in late summer, while spring is the perfect time to come and see migrant birds like redstarts,...Valley This is a delightful oak woodland to walk through - especially in spring and early summer when lots of migrating birds come to breed ... Fowlmere Fowlmere's reedbeds and pools are fed by natural chalk springs, and a chalk stream runs through the reserve. Special birds ... There are common woodland birds in spring and turtle doves in spring and summer. Haweswater If you want to see a golden ...
... In spring, the marshes are filled with the atmospheric calls of lapwings and redshanks, all breeding on one of the UK's ...Butley river and Ore estuary, Boyton Marshes attracts breeding wading birds in spring and ducks, geese and swans in winter. It's also ... The moorland landscape looks especially colourful in late summer, while spring is the perfect time to come and see migrant birds like redstarts,...Valley This is a delightful oak woodland to walk through - especially in spring and early summer when lots of migrating birds come to breed ...
Mass-energy spectra of fission fragments in the reaction {sup 242m}Am(n{sub th},f)
Energy Technology Data Exchange (ETDEWEB)
The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.
1994-12-01
HORIZON SENSING (PROPOSAL NO.51)
Energy Technology Data Exchange (ETDEWEB)
Real-time horizon sensing on continuous mining machines is becoming an industry tool. Installation and testing of production-grade Horizon Sensor (HS) systems continued this quarter at Monterey Coal Company (ExxonMobil), Mountain Coal Company West Elk Mine (Arch), and Ohio Valley Coal Company (OVC). Monitoring of system function, user experience, and mining benefits is ongoing. All horizon sensor components have finished MSHA (U.S.) and IEC (International) certification.
2003-07-01
Chemical evolution of formation waters in the Palm Valley gas field, Northern Territory
International Nuclear Information System (INIS)
The chemical composition and evolution of formation waters associated with gas production in the Palm Valley field, Northern Territory, has important implications for reservoir management, saline water disposal, and gas reserve calculations. Historically, the occurrence of saline formation water in gas fields has been the subject of considerable debate. A better understanding of the origin, chemical evolution and movement of the formation water at Palm Valley has important implications for future reservoir management, disposal of highly saline water and accurate gas reserves estimation. Major and trace element abundance data suggest that a significant component of the highly saline water from Palm Valley has characteristics that may have been derived from a modified evaporated seawater source such as an evaporite horizon. The most dilute waters probably represent condensate and the variation in the chemistry of the ...
International Nuclear Information System (INIS)
Within the United Kingdom, the regulatory body having responsibility for the licensing of nuclear installations is the Health and Safety Executive (HSE). The Nuclear Installations Inspectorate (NII) is that part of HSE which administers this function. Discussions on the applicability of quality assurance (QA) to licensed sites began in 1974, and an internal report was published in 1975. In parallel with work going on at the International Atomic Energy Agency (IAEA) to prepare Quality Assurance for Safety in Nuclear Power Plants: A Code of Practice, Safety Series No. 50-C-QA, NII published a second report in 1978 entitled A Guide to the Quality Assurance Programme for Nuclear Power Plants. In 1980, the construction of advanced gas cooled reactors at Heysham 2 and at Torness was licensed, and a condition was attached to the licences requiring the licensees to submit their QA arrangements to the NII for approval. The licensees' response was to produce separate QA ...
1988-11-07
Power Systems Development Facility Gasification Test Run TC07
Energy Technology Data Exchange (ETDEWEB)
This report discusses Test Campaign TC07 of the Kellogg Brown & Root, Inc. (KBR) Transport Reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). The Transport Reactor was operated as a pressurized gasifier during TC07. Prior to TC07, the Transport Reactor was modified to allow operations as an oxygen-blown gasifier. Test Run TC07 was started on December 11, 2001, and the sand circulation tests (TC07A) were completed on December 14, 2001. The coal-feed tests (TC07B-D) were started on January 17, 2002 and completed on April 5, 2002. Due to operational difficulties with the reactor, the ...
2002-04-05
Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1
Energy Technology Data Exchange (ETDEWEB)
Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other hand, the problem of wall thinning in the feeder pipes became of great concern since 1996. Inspections, in compliance with CSA ...
2005-07-01
Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1
International Nuclear Information System (INIS)
Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other hand, the problem of wall thinning in the feeder pipes became of great concern since 1996. Inspections, in compliance with CSA ...
2005-10-27
Energy Technology Data Exchange (ETDEWEB)
Friede and Goldman Ltd. of New Orleans, Louisiana has a successful drilling rig, the L-780 jack-up series. The triangular-shaped drilling vessel measures 180 x 176 ft. and is equipped with three 352 ft legs including spud cans. It is designed to work in up to 250 ft waters and drill to 20,000 ft depths. The unit is scheduled to begin initial drilling operations in the Gulf of Mexico for Arco. Design features are included for the unit. Davie Shipbuilding Ltd. has entered the Mexican offshore market with the signing of a $40,000,000 Canadian contract for a jack-up to work in 300 ft water depths. Baker Marine Corporation has contracted with the People's Republic of China for construction of two self-elevating jack-ups. The units will be built for Magnum Marine, headquartered in Houston. Details for the two rigs are given. Santa Fe International Corporation has ordered a new jack-up rig to work ...
1981-02-01
Floating oil production unit slated in small field off Gabon
Energy Technology Data Exchange (ETDEWEB)
This paper reports on the first U.S. tanker converted to a floating production, storage, and offloading (FPSO) unit which takes up station in Gombe-Beta field off Gabon by Dec. 1. FPSO Ocean Producer will work under a 3 year, day rate contract let late in 1990 by Amoco-Gabon Bombe Marin co., a unit of Amoco Production Co. (OGJ, Dec. 24, 1990, p. 27). Gombe-Beta field is in the Atlantic Ocean about 70 miles south of Port Gentil, Gabon. Ocean Producer will be moored in 50 ft of water 3.7 miles off Gabon, with Bombe-Beta's unmanned production platform about 820 ft astern. The vessel will be held in position by a disconnectable, asymmetric, six point, spread mooring system, It is owned and operated by Oceaneering International Services Ltd. (OISL). Affiliate Oceaneering Production Systems (OPS) converted the 78,061 dwt oil tanker MT Baltimore Sea at a capital cost of $25 million at Gulf Copper Manufacturing ...
1991-10-14
Energy Technology Data Exchange (ETDEWEB)
Corrective Action Unit (CAU) No. 92, the Area 6 Decontamination Pond Facility (DPF), is an historic disposal unit located at the Nevada Test Site (NTS) in Nye County, Nevada (Figures 1 - 1, 1-2, and 1-3). The NTS is operated by the U.S. Department of Energy, Nevada Operations Office (DOE/NV), which has been required by the Nevada Division of Environmental Protection (NDEP) to characterize the DPF under the requirements of the Resource Conservation and Recovery Act (RCRA) Part A Permit (NDEP, 1995) for the NTS and Title 40 Code of Federal Regulations (CFR) Part 265 (1996c). The DPF is prioritized in the Federal Facility Agreement and Consent Order (FFACO, 1996) but is governed by the permit. The DPF was characterized through sampling events in 1994, 1996, and 1997. The results of these sampling events are contained in the Final Resource Conservation and Recovery Act Industrial Site Environmental ...
1997-10-01
Regulatory experience on safety system instrument uncertainty of Wolsong units
International Nuclear Information System (INIS)
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by ...
2001-05-01
RAAN Conference. Support of Nuclear Power. Opening talk
International Nuclear Information System (INIS)
Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fructified in the construction of Units 2-5 to be built. The Romanian Ministry of Education and Research implemented a nuclear national program for research and development taking into account the European Union requirements and recommendations, the cooperation with the IAEA - Vienna and the Romanian government policy on short and medium terms in the nuclear field. The research-development program targeted: the reactor physics and nuclear fuel management; the ...
2002-09-06
Energy Technology Data Exchange (ETDEWEB)
The object of this survey of small US electric utility systems was to determine the potential utilization of small, fuel-flexible, advanced-cycle combustion turbines for power generation. Three prototype concepts were evaluated. Concept A: a 2.5 MWe externally fired, closed-cycle combustion turbine, with fluidized-bed combustor, burning solid fuels. Concept B: an open 3.8 MWe, indirect-fired, combined-cycle turbine system using solid, liquid or gaseous fuels, with downstream stack cleanup. Concept C: 11.6 MWe, utilizing an open, direct-fired, combined-cycle turbine arrangement, gas or oil fueled employing components of advanced development. It was presumed such units might be commercially available circa 1985 to 1990. Fifty-three utilities, encompassing a variety of ownerships, geographical distribution and system sizes, were interviewed on-site. Questions covered the probable use of such generating concepts and their perceived attributes. The report presents the ...
1981-04-01
Effect of boric acid on steam generator corrosion
International Nuclear Information System (INIS)
Project RPS116, ''Implementation of Boric Acid in the Field,'' was designed to demonstrate that a selected steam generator boric acid treatment is effective in arresting the progressing of denting in an operating steam generator. The PWR nuclear steam generators chosen for the testing were those at the Indian Point Unit 3 nuclear site. Hydrogen monitoring measurements and eddy current examinations had indicated that the Indian Point Unit 3, Series 44 steam generators had already reached an advanced stage of denting and tube support plate ligament discontinuities were observed. The objective of the boric acid treatment was to reduce the rate of denting by attempting to reproduce in the field the positive results achieved with boric acid in laboratory-simulated denting tests. Laboratory testing has indicated that implementation of a four day low power (25% power) boric acid soak with 50 ppm boron as boric acid followed by ...
1985-03-01
Advanced direct coal liquefaction concepts. Quarterly report, January 1, 1993--March 31, 1993
Five barrels of a Wilsonville process derived solvent (V-1074) from Black Thunder coal were obtained. This material boils within the preferred gas oil range, is more aromatic than previous solvents, and will therefore be used for the bench unit studies. Several repeat runs were performed in the autoclave to confirm the results of the matrix study. In addition, runs were carried out with different catalysts, with agglomerates and with the V-1074 solvent. The results of the autoclave runs were analyzed with respect to coal conversion, CO conversion, oil yield, hydrogen consumption and oxygen removal. It was concluded that the best operating conditions for the first stage operation was a temperature of at least 390{degrees}C, residence time of at least 30 minutes, cold CO pressure of at least 600 psig and potassium carbonate catalyst (2% wt on total feed). The data also indicated however, that the coal conversion goes through ...
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation ...
1997-12-31
Renewal of existing fossil-fired plants incorporating fully-fired combined cycle
Energy Technology Data Exchange (ETDEWEB)
The present article describes the features of the fully-fired combined cycles and the outline of the plant. Hitachi has optimized fully-fired combined cycle systems by executing a heat recovery type combined cycle. For the fully-fired combined cycles, it is possible to raise plant efficiency through the selection of adequate gas turbine types and cycles. It is possible to apply existing boiler facilities, fuel combustion systems, and stacks. It is possible to execute civil and architectural works on existing plants in-service as well as modification works during routine inspections. The NOx increment by gas turbine unit installations can be reduced by denitration plant modifications. Examples of the fully-fired combined cycles under planning are also introduced. Furthermore, the relational technique and operational characteristics are mentioned, as for combustion characteristics under low oxygen concentration in the wind box, NOx emissions on ...
1993-02-01
Remediation process technology for ground water
Energy Technology Data Exchange (ETDEWEB)
The operation of industrial facilities has generally resulted in contamination of the surrounding soils and ground water. A variety of methods have been proposed for the remediation of contaminated sites. This paper presents new process technology that is capable of performing treatment on ground water or soil washing leachates. The process is targeted to treat low levels of radioactivity, organics and heavy metals present in the aqueous solutions, to be easily transported and provide simple operation on-site and provide an effluent that meets the specified discharge quality. The purification process involves sequential chemical treatment and filtration. The paper will describe the development of the technology and review the current progress in its use to remediate contaminated sites at Chalk River. The application of the process technology has demonstrated that the ambitious goal of setting the effluent targets to meet the drinking water ...
1993-12-31
Remediation process technology for ground water
International Nuclear Information System (INIS)
The operation of industrial facilities has generally resulted in contamination of the surrounding soils and ground water. A variety of methods have been proposed for the remediation of contaminated sites. This paper presents new process technology that is capable of performing treatment on ground water or soil washing leachates. The process is targeted to treat low levels of radioactivity, organics and heavy metals present in the aqueous solutions, to be easily transported and provide simple operation on-site and provide an effluent that meets the specified discharge quality. The purification process involves sequential chemical treatment and filtration. The paper will describe the development of the technology and review the current progress in its use to remediate contaminated sites at Chalk River. The application of the process technology has demonstrated that the ambitious goal of setting the effluent targets to meet the drinking water ...
1993-09-05
Regulatory review of reactor physics design aspects of TAPP-3 and 4
International Nuclear Information System (INIS)
Atomic Energy Regulatory Board carries out the regulatory review of the reactor physics design, commissioning and operational aspects through Project Design Safety Committee and Specialist Group of reactor physicists with wide experience in the design, commissioning and operational safety review of NPPs. TAPP-3 and 4 PHWRs, being the first indigenous design of 540 MWe Units, are quite different than the standard 220 MWe PHWRs. The safety review of reactor physics design was quite complex, as majority of the systems were new. The Reactor Physics Specialist Group carried out extensive safety review of 540 MWe PHWR reactor physics design and made significant contributions of design modifications and improvements in the operational procedures. Some salient contributions include: Monitoring the core during bulk addition of moderator without the availability of shutdown systems. Logics for providing safety ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
This is the eighth part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This seventh appendix to the main report summarises and discusses the knowledge gained during the project and attempts to provide answers to various questions posed by the use of distributed ...
2003-07-01
Highlights of design and construction of Sendai Nuclear Power Station Unit No.2
International Nuclear Information System (INIS)
As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, improved steam generators, a reactor vessel cover of one-body type, ...
1985-01-01
FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling ...
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
The PERMCAT process chosen for the final clean-up stage of the Tokamak Exhaust Processing system of the ITER tritium plant combines in a single component a catalytic reactor and a permeator using Pd/Ag membranes. This study covers the mechanical behaviour of a Pd/Ag membrane under different operating conditions. The consequences of hydrogen uptake by the membrane during nominal operation but also during off-normal events are presented. Depending on the operating conditions, expansions around 2% and significant deformations are observed. Different mechanical designs of PERMCAT reactors are then discussed. The first generation comprises finger-type membranes and two new mechanical designs use either additional edge welded bellows or a special corrugated Pd/Ag membrane. These upgraded designs improve the robustness and simplify the geometry of the component. The experimental validation of these new units ...
2007-10-15
International Nuclear Information System (INIS)
The PERMCAT process chosen for the final clean-up stage of the Tokamak Exhaust Processing system of the ITER tritium plant combines in a single component a catalytic reactor and a permeator using Pd/Ag membranes. This study covers the mechanical behaviour of a Pd/Ag membrane under different operating conditions. The consequences of hydrogen uptake by the membrane during nominal operation but also during off-normal events are presented. Depending on the operating conditions, expansions around 2% and significant deformations are observed. Different mechanical designs of PERMCAT reactors are then discussed. The first generation comprises finger-type membranes and two new mechanical designs use either additional edge welded bellows or a special corrugated Pd/Ag membrane. These upgraded designs improve the robustness and simplify the geometry of the component. The experimental validation of these new units ...
2007-10-01
British Library Electronic Table of Contents (United Kingdom)
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...
2008-01-01
Exhaust emissions from an indirect injection dual-fuel engine
Energy Technology Data Exchange (ETDEWEB)
Diesel engines operating on gaseous fuels are commonly known as dual-fuel engines. In the present work, a single-cylinder, compression ignition, indirect injection research (Ricardo E6) engine has been installed at United Arab Emirates University for investigation of the exhaust emissions when the engine is operating as a dual-fuel engine. The influence of changes in major operating and design parameters, such as the concentration of gaseous fuel in the cylinder charge, pilot fuel quantity, injection timing and intake temperature, on the production of exhaust emissions was investigated. Diesel fuel was used as the pilot fuel, while methane or propane was used as the main fuel which was inducted in the intake manifold and mixed with the intake air. The experimental investigations showed that the poor emissions at light loads can be improved significantly by increasing the concentration of gaseous fuel ...
2000-04-01
Convolution powers in the operator-valued framework
We consider the framework of an operator-valued noncommutative probability space over a unital C*-algebra B. We show how for a B-valued distribution \\mu one can define convolution powers with respect to free additive convolution and with respect to Boolean convolution, where the exponent considered in the power is a suitably chosen linear map \\eta from B to B, instead of being a non-negative real number. More precisely, the Boolean convolution power is defined whenever \\eta is completely positive, while the free additive convolution power is defined whenever \\eta - 1 is completely positive (where 1 stands for the identity map on B). In connection to these convolution powers we define an evolution semigroup related to the Boolean Bercovici-Pata bijection. We prove several properties of this semigroup, including its connection to the B-valued free Brownian motion. We also obtain two results on the operator-valued analytic ...
2011-01-01
Blast designs to improve dragline stripping rates. Final report: Phase I
International Nuclear Information System (INIS)
This report is in accordance with Phase I of the United States Department of Energy and Bureau of Mines Contract No. USDOE DE-AC01-77QQ90147. A thorough literature search was conducted and the current mining practice at nine coal stripping operations reviewed in detail. A review of the state of the art of blast design using current theory and practice is presented. Based upon this information, a series of recommendations are presented and a detailed test program is outlined for three operations. The recommendations to increase dragline productivity by improved blast design are directed at filling the bucket more quickly, with greater consistency and with a better fill factor: (a) overburden fragmentation, (b) muckpile displacements, and (c) blasting reliability. Recommended blast design concepts and operating procedures to provide the desired blast performance include: (1) Increase energy input per BCY ...
Advanced evaporator technology progress report FY 1992
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the work that was completed in FY 1992 on the program {open_quotes}Technology Development for Concentrating Process Streams.{close_quotes} The purpose of this program is to evaluate and develop evaporator technology for concentrating radioactive waste and product streams such as those generated by the TRUEX process. Concentrating these streams and minimizing the volume of waste generated can significantly reduce disposal costs; however, equipment to concentrate the streams and recycle the decontaminated condensates must be installed. LICON, Inc., is developing an evaporator that shows a great deal of potential for this application. In this report, concepts that need to be incorporated into the design of an evaporator operated in a radioactive environment are discussed. These concepts include criticality safety, remote operation and maintenance, and materials of construction. Both solubility and vapor-liquid equilibrium ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
At the Huizhou oil field in China the FPSO Munin of Bluewater completely relies on five computer controlled propulsion screws to position itself, a so-called Dynamic Positioning (DP) system. In this article report is given of training given to the crew of the FPSO Munin. A floating production, storage and offloading (FPSO) unit is a floating vessel used by the offshore industry for the processing and storage of oil and gas. [Dutch] Op het Huizhou oileveld in China vertrouwt de FPSO (floating production, storage and offloading unit) Munin van Bluewater uitsluitend op een vijftal computergestuurde voorstuwingsschroeven om zichzelf in positie te houden, een zogenaamd Dynamisch Positionering (DP) systeem. In dit artikel wordt verslag gedaan van en uitleg gegeven over trainingen die zijn gegeven aan de bemanning van de FPSO Munin.
2010-07-15
Removal of iodine from nuclear fuel reprocessing plant off-gases by Corona discharge
International Nuclear Information System (INIS)
Corona discharge has been investigated for the treatment of off-gases arising from nuclear fuel reprocessing operations, in particular Dissolver off-Gases (DOG). Results are presented of studies carried out on single tube, wire-in-tube experimental rigs to examine the behaviour of molecular iodine, organic iodine and oxides of nitrogen (NOx). The effect of corona current, gas residence time, electrode configuration, oxygen concentration and moisture content are discussed. Decontamination Factors (DF's) of greater than 104 (> 99.99% removal) have been achieved for both molecular and organic iodine. Efficient NOx removal has also been demonstrated. Moisture and NOx both interfere with iodine removal above certain concentrations. To overcome this a two stage corona system has been developed consisting of a primary continuously irrigated corona unit followed by a dehumidifier prior to a secondary dry corona unit.
1991-10-21
Pollution in the Gulf: Monitoring the marine environment
International Nuclear Information System (INIS)
More than 2 years after the Gulf conflict, scientists are continuing to keep a close watch on marine pollution stemming from the war. Following the conflict in early 1991, major concern was raised worldwide when an estimated four to eight million barrels of crude oil were directly released into the Persian Gulf from the Sea Island terminal in Kuwait. Such amounts clearly made it the largest oil spill in history. The catastrophe was exacerbated when Kuwaiti oil fields were ignited. The magnitude of the pollution, and the types of toxic contaminants involved, led to a worldwide response through the United Nations system. An inter-agency plan of action was developed quickly. As one of its steps, the co-ordinating agency - the United Nations Environment Programme (UNEP) - asked the IAEA's Marine Environment Laboratory (MEL) in Monaco to help make a preliminary assessment of the situation. The Laboratory's main goal in initial surveys was to map the ...
International Nuclear Information System (INIS)
Full text. This research assesses models for new nuclear build in European Union (EU) member states to find the most stable form. The countries examined in this study are the United Kingdom and Romania. The results attest that due to various historical, political, competition, and electricity market structural conditions Romania and the United Kingdom have emerged with different models for new build nuclear projects. This paper begins with an assessment of the effects on the nuclear sector from energy, environmental and competition legislation in the EU. Then the political and economic climate of the aforementioned EU member states is completed. Following this an overview of the market structure of the electricity sector in those respective countries is conducted. Then the key research on the models and the phases of new nuclear build are explored. The research concludes each model has transcended from different political and economic forces, ...
2009-10-12
Getting America Ready for Japanese Science and Technology.
The proceedings of a conference on the development of language capabilities to prepare United States scientists to share in scientific and technological development with Japan include these papers: "Are Japanese Language Programs Reaching Scientists and Engineers?"; "Japanese Language Study for Engineers: High Tech Perspectives"; "Applied Japanese Studies for Science and Engineering at American Universities"; "Training and Certifying Japanese Technical Translators"; "Designing Effective Language Teaching for Professionals"; "Problems in Teaching Technical Japanese"; "Commentary" A Cautious and Deliberate Strategy Is Needed"; "Establishing a Japanese High-Technology Information Company in the United States"; "The Problems of Operating a Technical Translation Company in Japan";"The Japan Information Center of Science and Technology"; "A National Agenda for Japanese Language Training"; "National Language Policies and the 99th ...
1985-05-15
Energy Technology Data Exchange (ETDEWEB)
The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy Conservation Devices for (8) one bedroom homes. CDC staff designed all solar systems and CETA trainees (County and City vocational training program enrollees) ...
1983-10-19
Energy Technology Data Exchange (ETDEWEB)
This report provides an assessment of the designs of turret and swivel systems for floating production, storage and offloading (FPSO) vessels and floating storage Units (FSU) which are either purpose built or converted from tankers. Use of FPSO and FSO in the North Sea with the move to subsea and deepwater production is discussed, and the background to FPSO and FSU turret systems is traced. Details are given of general issues relating to ship structure, systems affecting the turret, swivel systems, mooring systems, turret loading, scaffolding and support structure, on-board personnel, and construction standards. Turret system components and types are described, and failure modes, operation and safety relevant components are examined. Inspection and maintenance, examples of good and poor practice, and applicable regulations are considered. Annexes list UK installations and present information on individual turret design, fluid transfer systems, ...
2002-07-01
Development of radioisotope tracer technology
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the measured activity loss ...
2000-04-01
Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration
Energy Technology Data Exchange (ETDEWEB)
A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Factors important in choosing between process concepts were mechanical complexity and amenability to scale-up studies. The culmination of this work was a process concept known as Staged Turbulent Bed Retorting Process (STB), which has now been tested in pilot plants. Operating conditions are described. The environment in the retort section can be described as a staged, moving bed of particles, in which a portion of the particles are fluidized at gas velocities well below minimum fluidization velocity of many of the particles. Research and engineering evaluations have established that the STB provides prospects for the responsible development of oil shale resources on a commercial scale. A 320 ton/d semiworks unit, the next technological step, will be commissioned shortly. This unit will be large enough to provide scale-up data for design of modules and to demonstrate the entire process, generating data needed to optimize, ...
1982-03-01
International Nuclear Information System (INIS)
A series of cation exchange membranes was produced by impregnating and coating both sides of a quartz web with a Nafion solution (1100 EW, 10%wt in water). Inert filler particles (SiO_2, ZrO_2 or TiO_2; 5-20%wt) were incorporated into the aqueous Nafion solution to produce robust, composite membranes. Ion-exchange capacity/equivalent weight, water take-up, thickness change on hydration and ionic and electrical conductivity were measured in 1 mol dm"-"3 sulfuric acid at 298 K. The TiO_2 filler significantly impacted on these properties, producing higher water take-up and increased conductivity. Such membranes may be beneficial for proton exchange membrane (PEM) fuel cell operation at low humidification. The PEM fuel cell performance of the composite membranes containing SiO_2 fillers was examined in a Ballard Mark 5E unit cell. While the use of composite membranes offers a cost reduction, the unit cell performance was ...
2010-09-01
Biological conversion of synthesis gas. Limiting conditions/scale-up
Energy Technology Data Exchange (ETDEWEB)
The purpose of this research is to develop a technically and economically feasible process for biologically producing H(sub 2) from synthesis gas while, at the same time, removing harmful sulfur gas compounds. Six major tasks are being studied: 1. Culture development, where the best cultures are selected and conditions optimized for simultaneous hydrogen production and sulfur gas removal; 2. Mass transfer and kinetic studies in which equations necessary for process design are developed; 3. Bioreactor design studies, where the cultures chosen in Task 1 are utilized in continuous reaction vessels to demonstrate process feasibility and define operating conditions; 4. Evaluation of biological synthetic gas conversion under limiting conditions in preparation for industrial demonstration studies; 5. Process scale-up where laboratory data are scaled to larger-size units in preparation for process demonstration in a pilot-scale ...
1993-09-01
Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the finding of the study was utilized for the ...
2005-11-23
A New Landscape: Opportunities and Pitfalls for Universities Expanding in the Persian Gulf
Dozens of universities--primarily from the United States, United Kingdom, and Australia--are eyeing the Gulf region as a largely untapped reservoir of academic potential and economic opportunity. During the last few years, UAE states like Dubai, Abu Dhabi, Qatar, and Ras al Khaymah have spent billions to entice top universities. And many colleges are responding--examples include New York University's campus in Abu Dhabi; Michigan State University's school in Dubai; and big names like Cornell, Northwestern, and Carnegie Mellon that have set up shop in Qatar. Typically, Western universities begin their foray into the Gulf by teaming with local investors. The colleges oversee the academic infrastructure while the investors front all operational costs. The partnerships are complicated. Some investors are mining the UAE's educational zeal for profit. In other cases, schools join forces with the region's numerous royal families, ...
2008-12-01
Coordinating decentralized optimization of truck and shovel mining operations
Energy Technology Data Exchange (ETDEWEB)
Canada's oil sands contain the largest known reserve of oil in the world. Oil sands mining uses 3 functional processes, ore hauling, overburden removal and mechanical maintenance. The industry relies mainly on truck-and-shovel technology in its open-pit mining operations which contributes greatly to the overall mining operation cost. Coordination between operating units is crucial for achieving an enterprise-wide optimal operation level. Some of the challenges facing the industry include multiple or conflicting objectives such as minimizing the use of raw materials and energy while maximizing production. The large sets of constraints that define the feasible domain pose as challenge, as does the uncertainty in system parameters. One solution lies in assigning truck resources to various activities. This fully decentralized approach would treat the optimization of ore ...
2006-07-01
This report presents the operating results for Run 244 at the Advanced Coal Liquefaction R and D Facility in Wilsonville, Alabama. This run was made in an all-distillate Integrated Two-Stage Liquefaction (ITSL) mode using Illinois 6 coal from the Burning Star mine. The primary objective was to demonstrate the effects of temperature programming an aged catalyst batch on the ITSL product slate, especially on the net C/sub 1/-C/sub 5/ gas production and hydrogen consumption. Other objectives were to demonstrate the effect of fresh catalyst addition and to age the catalyst batch for an extended run with catalyst addition and withdrawal. Run 244 began on 4 July 1983 and continued through 27 September 1983. During this period, 182.9 tons of coal was fed in 1872 hours of operation. Seven special product workup material balances and two hydrotreater balances were defined, and the results are presented herein. From 27 to 30 September, 7.4 tons of Wyodak ...
1984-05-01
Seven years of operating experience with amorphous metal transformers
Energy Technology Data Exchange (ETDEWEB)
Amorphous metals have an atomic structure resembling that of glass, and have high strength, toughness, and excellent magnetic properties for transformer applications. This type of metal has the potential to reduce the core losses of electromagnetic apparatus by 70-75% compared to the best grain-oriented silicon iron currently used. If all 4 million distribution transformers now in service in Canada were replaced by the more efficient amorphous units, it is estimated that over 5.25 billion kWh of energy could be saved annually. The experience of the General Electric (GE) Company and other researchers with operation of amorphous transformers is described. GE first tried operating amorphous metal transformers on a utility distribution system in April 1982. The shell-type cruciform design showed stable, low-loss performance over eight years of service. GE and the Electric Power Research Institute cooperated on manufacturing and ...
1991-05-01
Remedial investigation/feasibility study report for lower Watts Bar Reservoir Operable Unit
Energy Technology Data Exchange (ETDEWEB)
This document is the combined Remedial Investigation and Feasibility Study Report for the Lower Watts Bar Reservoir (LWBR) Operable Unit (OU). The LWBR is located in Roane, Rhea, and Meigs counties, Tennessee, and consists of Watts Bar Reservoir downstream of the Clinch River. This area has received hazardous substances released over a period of 50 years from the U.S. Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). As required by this law, the ORR and all off-site areas that have received containments, including LWBR, must be investigated to determine the risk to human health and the environment resulting from these releases, the need for any remedial action to reduce these risks, and the remedial actions that are most feasible for implementation in this OU. Contaminants from the ORR are primarily transported ...
1994-08-01
Description of work vadose drilling at the 1301-N and 1325-N facilities, 100-NR-1 operable unit
Energy Technology Data Exchange (ETDEWEB)
This description of work (DOW) details the field activities associated with the sampling of the vadose zone soils beneath the 1301-N and 1325-N cribs and trenches and will serve as a field guide for those performing the work. These activities are undertaken pursuant to the Hanford Federal Facility Agreement and Consent Order (Ecology et al., 1994a) Milestone M-16-94-01H-Tl and the June 30, 1994 Milestone Change Request M-16-94-02 (Ecology et al., 1994b). Three vadose zone borings, 1301-N-1, 1301-N-2, and 1325-N-1, will be constructed to investigate the vertical and horizontal distribution of radionuclide contamination in sediments beneath the cribs and trenches. The boreholes are also intended to intersect subsurface areas that may have been contaminated by dangerous wastes, i.e., metals, in effluent disposed during past operation of the facilities. This limited field investigation will provide data for the evaluation of remedial alternatives. Data from the ...
1994-08-01
Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests
Energy Technology Data Exchange (ETDEWEB)
The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was ...
1998-10-01
Rack and pinion based fuelling machine of 540 MWe PHWR-from concept to refuelling
International Nuclear Information System (INIS)
On-power refuelling is an integral feature of PHWR units. The most notable aspect of refuelling system of 540 MWe PHWR (TAPP-3 and 4) is that the FM Head is based on rack and pinion mechanism for B-ram and C-ram of Ram assembly. Latch ram used during plug operations, is assembled in between B-ram and C-ram and is moved by a ballscrew driven by oil hydraulic motors. This unique design has been employed for the first time in a PHWR unit. In comparison, B-ram is ballscrew driven and C-ram is moved by heavy water hydraulic force in FM Heads of 220 MWe PHWR units. Over the years, a number of design improvements have been carried out in the 220 MWe Fuelling Machines to meet the challenge of increasing demands of higher refuelling rates. However, in 540 MWe unit, the average refuelling rate for an equilibrium core is nearly twice that of 220 MWe units. Apart from other ...
2006-11-13
Using the Am9511 arithmetic processing unit with the Motorola M6800 microprocessor
Using the Am9511 arithmetic processing unit with the Motorola M6800 microprocessor
1979-01-01
International Nuclear Information System (INIS)
On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).
Waste characterization study for the Kemp's Ridley sea turtle. Technical memo
Energy Technology Data Exchange (ETDEWEB)
The Kemp's Ridley sea turtle, Lepidochelys kempi, is an endangered species. The National Marine Fisheries Service's Head Start program is part of an international operation to save the turtles from extinction. Under the Head Start program, eggs from the Ridley's only known wild nesting beach at Rancho Nuevo in Mexico are transported to Padre Island on the Texas coast to be hatched. The head start enables the turtles to develop a survival advantage. The principal objective was to develop baseline waste-characterization data required to design a waste-water treatment scheme for the Galveston Head Start facility. As a secondary objective, preliminary testing of some filtration components was undertaken to determine which units were most appropriate for inclusion in a wastewater treatment scheme.
1988-02-01
Utilization of low rank coals in liquefaction
Energy Technology Data Exchange (ETDEWEB)
The objective of the current MITRE study is to estimate the cost of the coal derived liquid products that result from processing low rank coals in the Wilsonville and HRI CTSL configurations. The resultant cost of liquids is then compared to liquids produced from bituminous coals. The methodology used to accomplish the above objective was to utilize the MITRE coal liquefaction cost model to assess the overall technical and economic performance of low rank coals in both the Wilsonville and HRI configurations. Actual test data from Wilsonville and HRI was used as the basis for these analyses. This test data is modified to simulate complete resid recycle extinction and to standardize the operating performance of the deashing unit. This corrected yield data is then used in the simulation models to predict the overall performance and economics of a conceptual commercial coal liquefaction facility. 9 refs., 7 figs.
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Coal can be converted to liquid fuels via three generically defined technologies: pyrolysis, direct hydroliquefaction, and indirect liquefaction. This paper presents a general overview of the indirect liquefaction technology and a discussion of processes tht are commercially available as well as those in the development stage. Finally, the objective of the DOE research and development program in conversion of synthesis gas derived from coal to transportation fuels is summarized. The current outlook for indirect liquefaction is encouraging. New facilities are being built in South Africe and New Zealand, and commercial plants could be designed and built for operation in the United States using proven technology. At the same time, developments in gasification as well as liquefaction catalysts and reactor technology promise significant improvements in indirect liquefaction processes in the years to come.
1982-01-01
Theoretical analysis of the DC electromagnetic flow coupler
Energy Technology Data Exchange (ETDEWEB)
A descriptive model and design procedure for the DC electromagnetic flow coupler is developed based on a quasi-one-dimensional analysis previously developed for the DC electromagnetic pump. It is shown that for a particular flow coupler geometry, the total efficiency and the pressure gradients through the pump and generator depend on two parameters - the Hartmann number and the ratio of the pump flow rate to generator flow rate. Thus, for a fixed Hartmann number the efficiency depends only on the flow ratio. However, for a fixed pressure rise through the pump it is shown that the efficiency depends only on the Hartmann number. Nomographs showing the operating characteristics and critical design points are presented. Example calculations for a full-size unit, suitable for use in a liquid-metal cooled fast breeder reactor, are also discussed using the design nomographs.
1983-03-01
The Authenticated Tracking and Monitoring System (ATMS) concept
Energy Technology Data Exchange (ETDEWEB)
The Authenticated Tracking and Monitoring System (ATMS) has been designed to address the need for global monitoring of the status and location of proliferation-sensitive items. Conceived to utilize the proposed Global Verification and Location System (GVLS) satellite link, ATMS could use the existing International Maritime Satellite commercial communication system until GVLS is operational. The ATMS concept uses sensor packs to monitor items and environmental conditions, collects a variety of events data through a sensor processing unit, and transmits the data to a satellite, which then sends data to ground stations. Authentication and encryption algorithms will be used to secure the data. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. This paper also discusses a possible proof-of-concept system demonstration.
1993-08-01
Tanker-based production eyed for Gulf of Mexico use
Energy Technology Data Exchange (ETDEWEB)
The new oil price environment is sending industry engineers back to the drawing board. The search is on for cost effective and perhaps unconventional deepwater production systems. One candidate for Gulf of Mexico deepwater tracts is a tanker-based floating production, storage, and offloading (FPSO) system. Substantial experience with tanker-based FPSO systems has proven them to be cost effective when the field is remote from existing production facilities and pipelines. A tanker-based system offers the unique feature of integrating production, storage, and offloading capabilities into a single unit. Such systems can be installed in 12 to 15 months and can even be leased, significantly improving an operator's cash flow.
1986-05-01
Energy Technology Data Exchange (ETDEWEB)
The main goal of this research is to delineate the wetting behavior of coal and it subsequent effects on fine coal processing. As both bulk and surface properties of coal are interrelated and have a controlling role on the performance of these processes, a detailed study has been undertaken to correlate their influence on both wetting behavior and the response of coal to flotation and other unit operations encountered in fine coal processing. During the last quarter, the effect of coal rank on water retention capacity was investigated. The effect of pH on the vacuum flotation yield and the effect of desliming on the film flotation response of coal were also studied. 6 refs., 5 figs.
1989-04-01
Summarization of radioactive effluent monitoring in Daya Bay Nuclear Power Station 1994-2002
International Nuclear Information System (INIS)
This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10"4, noble gas 2.03 x 10"4, halogen 0.13, aerosol 7.57 x 10"-"3. For "1"1"0"mAg, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997
2004-05-01
British Library Electronic Table of Contents (United Kingdom)
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency.The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It beg...
2008-01-01
Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)
2006-11-13
Sandwich belt high angle conveyors - applications in open pit mining
Energy Technology Data Exchange (ETDEWEB)
High angle conveyor (HAC) systems in open pit mining offer many advantages over the traditional, truck only, haulage systems, including: (1) superior energy efficiency, (2) less dependency on petroleum products, (3) less sensitivity to inflation, (4) less labor, (5) less excavation for the amount of ore recovered, and (6) less ramp construction and maintenance costs. Previous studies have revealed the technical and economic feasibility of high angle conveyors. The present paper introduces the Continental Conveyor sandwich belt HAC as the vital link to optimization of in-pit conveying systems. A test and demonstration unit, has been built and demonstrated. Discussion continues with the HAC systems to suit the various open pit mining operations and the corresponding characteristics of the system components, particularly the high angle conveyor. The range of HAC systems is discussed. (11 refs.)
1984-03-01
British Library Electronic Table of Contents (United Kingdom)
The paper deals with the reliability-based design optimization (RBDO) of a riser support installed on a floating production storage and offloading (FPSO) unit under operation, extreme, damaged, and one line failure cases and installation loading conditions. The optimization problem is formulated such that probabilistic thickness variables described with random characteristics are determined by minimizing the weight of the riser support structure subjected to stress constraints for the given target reliability. The initial design model is generated based on actual FPSO riser support specifications. The finite element analysis is conducted using NASTRAN, and the probabilistic optimal solutions are obtained via the moving least squares method in the context of RBDO using a response surface me...
2011-01-01
Radiation streaming analysis of horizontal penetrations in calandria vault of TAPP-3, 4
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)
2006-11-13
International Nuclear Information System (INIS)
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 ...
1988-01-01
Proposed roadmap for overcoming legal and financial obstacles to carbon capture and sequestration
Energy Technology Data Exchange (ETDEWEB)
Many existing proposals either lack sufficient concreteness to make carbon capture and geological sequestration (CCGS) operational or fail to focus on a comprehensive, long term framework for its regulation, thus failing to account adequately for the urgency of the issue, the need to develop immediate experience with large scale demonstration projects, or the financial and other incentives required to launch early demonstration projects. We aim to help fill this void by proposing a roadmap to commercial deployment of CCGS in the United States.This roadmap focuses on the legal and financial incentives necessary for rapid demonstration of geological sequestration in the absence of national restrictions on CO2 emissions. It weaves together existing federal programs and financing opportunities into a set of recommendations for achieving commercial viability of geological sequestration.
2009-03-01
OES receives permit for remediation of PCB contaminated soils
Energy Technology Data Exchange (ETDEWEB)
Ogden Environmental Services has announced that the Environmental Protection Agency (EPA) has issued a nation-wide federal permit allowing OES to use its circulating bed combustion (CBC) system for remediation of PCB contaminated soils. The landmark permit confirms the effectiveness of OES' CBC system and its ability to destroy PCBs without releasing harmful quantities of PCBs or other chemicals into the air. EPA headquarters issued the permit following their audit of trial burn operations of OES' CBC unit during September 1988 at the Arco Swanson River oil fields in the Kenai Wildlife Refuge, Kenai Peninsula, Alaska. The Arco project represents the world's first major remediation program using CBC technology and the largest PCB/soil cleanup to date.
1989-08-01
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional mathematical thermo-fluid model coupling the electrochemical kinetics with fluid dynamics was developed to simulate the heat and mass transfer in planar anode-supported solid oxide fuel cell (SOFC). The internal reforming reactions and electrochemical reactions of carbon monoxide and hydrogen in the porous anode layer were analyzed. The temperature, species mole fraction, current density, overpotential loss and other performance parameters of the single cell unit were obtained by a commercial CFD code (Fluent) and external sub-routine. Results show that the current density produced by electrochemical reactions of carbon monoxide cannot be ignored, the cathode overpotential loss is the biggest one among the three overpotential losses, and that the proper decrease of the operating voltage leads to the increase of the current density, PEN structure temperature, fuel utilization factor, fuel efficiency and power output of the ...
2009-01-15
International Nuclear Information System (INIS)
Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method
2010-10-01
Gas Research Institute wetland research program
Energy Technology Data Exchange (ETDEWEB)
As part of three ongoing research projects, the Gas Research Institute (GRI) is studying the natural gas industry`s impacts on wetlands and how to manage operations so that impacts can be minimized or eliminated. The objective of the first project is to gain a better understanding of the causes and processes of wetland loss in the Louisiana deltaic plain and what role gas pipeline canals play in wetland loss. On the basis of information gathered from the first projects, management and mitigation implications for pipeline construction and maintenance will be evaluated. The objective of the second project is to assess the floral and faunal communities on existing rights-of-way (ROWs) that pass through numerous types of wetlands across the United States. The emphasis of the project is on pipelines that were installed within the past five years. The objective of the third project is to evaluate the administrative, jurisdictional, technical, and ...
1992-12-01
Energy Technology Data Exchange (ETDEWEB)
A prototype trumpet type nonimaging secondary concentrator has been designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system and a preliminary set of operating tests has been carried out. The secondary is 26.7 cm (10.5 in.) deep by about 69 cm (27 in.) wide, and has a geometric concentration of 1.7X. The test units were fabricated from polished copper spinnings, overcoated with vapor deposited aluminum and aluminum oxide layers and are water cooled. The basic design considerations are reviewed, the objectives and test procedures for the experiment are summarized and some preliminary results are presented.
1996-11-01
Energy use analysis of selected palm-kernel oil mills in south western Nigeria
British Library Electronic Table of Contents (United Kingdom)
Energy use patterns and utilisation efficiencies in 40 factories producing palm kernel oil (PKO) in southwestern part of Nigeria were studied. The factories were stratified into small, medium and large scale categories based on the mode of operations and production capacities. Questionnaires were administered on the factories to obtain historical data on petrol, diesel and electricity consumption and PKO production outputs for seven years (1998-2004). Energy use efficiency indicators employed include: energy intensity (EI), energy cost per unit product (EC/P), energy ratio (ER), food energy ratio (FER) and percentage oil yield by weight. Results of the study indicated that averagely, 0.58, 0.53 and 0.74GJ/103l of PKO were needed in the small, medium and large PKO factories, respectively. T...
2008-01-01
ECOTRONIC - an electronic system for mixture formation
Energy Technology Data Exchange (ETDEWEB)
Fhe ECOTRONIC system developed by Bosch und Pierburg System oHG is an electronic system for mixture formation for Otto-cycle engines complying with high operational requirements. Engineers incorporated electronic control of the quantity of mixture and mixture enrichment for supplementary functions into a reliable, low-cost system, which will also comply with future requirements concerning fuel consumption, emissions and driveability. The author of the present article reduces the carburetor down to its basic systems, explains how supplementary functions were converted from mechanical to either open or closed-loop electronic control, and describes the newly developed actuators, the control unit making use of digital technology, and the results achieved.
1984-02-01
ECCS integrated test in TAPP-3 and 4
International Nuclear Information System (INIS)
Emergency Core Cooling System (ECCS) is a safety critical system provided to mitigate the consequence of Loss of Coolant Accident (LOCA) in PHWR. Unlike 220MWe, all header injection has been introduced in 540MWe to simplify the logic. ECCS Integrated Test is schematic approach to establish that ECC system will behave as per design intent during actual LOCA condition. Objective of ECCS Integrated test is to ascertain that various ECC system components operate as intended in design. Additionally, the various system resistances which form the input to LOCA analysis are validated. This test has been carried out by creating actual LOCA during cold and pressurised condition of PHT system to establish all phases of injection with overlap. This paper discusses the results obtained during the Integrated Test and comparison with the prediction during the commissioning of first unit of 540 MWe. (author)
2006-11-13
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose monitoring at TAPS 3 and 4. (author)
2008-11-19
Development of a greenhouse-type solar dryer for medicinal plants and herbs
Energy Technology Data Exchange (ETDEWEB)
The economy of medicinal plant production is burdened considerably by the energy costs of drying. To substitute fossil energy, a solar heated dryer was developed, taking a plastic film greenhouse as superstructure to lower the initial costs. The solar air heaters, being incorporated into the roof, consist of a black absorber tissue, which is placed between the transparent cover of the greenhouse and an insulating air-bubble foil. To obtain a modular design, the system is structured along the ridge into segments of 2 m width. Each segment forms an independent solar air heater/batch dryer unit and is operated by a fan with a power consumption of 500 W. A prototype was tested in Yugoslavia, drying mint, sage and hops. (author).
1989-01-01
Design modifications in radiation monitoring system at Tarapur Atomic Power Station 3 and 4
International Nuclear Information System (INIS)
Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)
2006-11-13
British Library Electronic Table of Contents (United Kingdom)
Abstract Characteristics of batch rotor-stator mixer performance are elucidated by shaft torque and angle resolved 2D PIV measurements obtained in a full-scale, custom build, bottom-mounted, rotor-stator mixer unit operating in the turbulent regime with water as working fluid. Measurements have been acquired at various rotor speeds corresponding to impeller based Reynolds numbers between 2.0--105 and 8.5--105. The use of a transparent Plexiglas stator facilitated PIV measurements inside and outside the stator as well as into the stator slots themselves. The governing mechanisms controlling the complex flow structures, flow rates, power dissipation, velocity fields, strain rate fields and turbulence intensity fields are explained, highlighting the influence on rotor-stator mixer performance...
2011-01-01
Benefit analysis and evaluation of pumped-storage plant in Taipower system
Energy Technology Data Exchange (ETDEWEB)
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.
1995-12-31
Behaviour of the steam generators in the Belgian nuclear power plants
International Nuclear Information System (INIS)
After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).
1986-04-15
Application of an inverse input/output mapped ANN as a power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
An artificial neural network (ANN), trained as an inverse of the controlled plant, to function as a power system stabilizer (PSS) is presented in this paper. In order to make the proposed ANN PSS work properly, it was trained over the full working range of the generating unit with a large variety of disturbances. Data used to train the ANN PSS consists of the control input and the synchronous machine response with an adaptive PSS (APSS) controlling the generator. During training, the ANN was required to memorize the reverse input/output mapping of the synchronous machine. After the training, the output of the synchronous machine was applied as the input of the ANN PSS and the output of the ANN PSS was used as the control signal. Simulation results show that the proposed ANN PSS can provide good damping of the power system over a wide operating range and significantly improve the system performance.
1994-09-01
An adaptive power system stabilizer based on the self-optimizing pole shifting control strategy
Energy Technology Data Exchange (ETDEWEB)
An adaptive power system stabilizer (APSS) employing a new self-optimizing pole shifting control strategy and its application to a power system are described in this paper. Based on an identified model of the system, the control is computed by an algorithm which shifts the closed-loop poles of the system to some optimal locations inside the unit circle in the z-domain to minimize a given performance criterion. With the self-optimization property, outside intervention in the controller design procedure is minimized, thus simplifying the tuning procedure during commissioning. Also, a new method of calculating the variable forgetting factor in real-time parameter identification is discussed. Studies show that the proposed APSS can provide good damping of the power system over a wide operating range and significantly improve the dynamic performance of the system.
1993-12-01
International Nuclear Information System (INIS)
The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.
1980-10-01
In the Advance Coal Liquefaction Concept Proposal (ACLCP) carbon monoxide (CO) and water have been proposed as the primary reagents in the pretreatment process. The main objective of this project is to develop a methodology for pretreating coal under mild conditions based on a combination of existing processes which have shown great promise in liquefaction, extraction and pyrolysis studies. The aim of this pretreatment process is to partially depolymerise the coal, eliminate oxygen and diminish the propensity for retograde reactions during subsequent liquefaction. The desirable outcome of the CO pretreatment step should be: (1) enhanced liquefaction activity and/or selectivity toward products of higher quality due to chemical modification of the coal structure; (2) cleaner downstream products; (3) overall improvement in operability and process economics.
1992-04-01
Advanced direct liquefaction concepts for PETC generic units
In the Advance Coal Liquefaction Concept Proposal (ACLCP) carbon monoxide (CO) and water have been proposed as the primary reagents in the pretreatment process. The main objective of this project is to develop a methodology for pretreating coal under mild conditions based on a combination of existing processes which have shown great promise in liquefaction, extraction and pyrolysis studies. The aim of this pretreatment process is to partially depolymerise the coal, eliminate oxygen and diminish the propensity for retograde reactions during subsequent liquefaction. The desirable outcome of the CO pretreatment step should be: (1) enhanced liquefaction activity and/or selectivity toward products of higher quality due to chemical modification of the coal structure; (2) cleaner downstream products; (3) overall improvement in operability and process economics.
1992-04-01
A mobile gamma scanning system for detecting radiation anomalies
Energy Technology Data Exchange (ETDEWEB)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
1983-09-01
A mobile gamma scanning system for detecting radiation anomalies
International Nuclear Information System (INIS)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
A guide to developing and implementing safety checklists: Plant steam utilities
British Library Electronic Table of Contents (United Kingdom)
Abstract Steam generation is an integral part of most chemical process plants; however, the steam plant often is or can be overlooked in the area of hazard analysis. The reasons for this oversight are obvious: steam generation is considered to be an old and well-understood process, and steam boiler systems are often not considered to pose the same hazards as other plant units. However, modern steam boiler systems are fueled with natural gas, pulverized coal, and/or fuel oil; each of which poses significant fire and explosion hazards. For example, a moderately sized chemical plant's boiler house may have two or three boilers operating at 240 MMBTU/hr, with each using approximately 11 ton/hr of subbituminous pulverized coal feed. Chemical plants rely on equipment design and installation, mai...
2011-01-01
IMPROVED NATURAL GAS STORAGE WELL REMEDIATION
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) ...
2001-12-01
Energy Technology Data Exchange (ETDEWEB)
Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} (from oxidation of NO in the vapor space) concentrations were representative of those ...
1995-05-01
Genetic control of cotton insects: The pink bollworm as a working programme
International Nuclear Information System (INIS)
Establishment of a continuous population has been prevented over a 24 year period in the San Joaquin Valley, USA, through continuous, daily in-season release of sterile pink bollworms based on an extensive trap monitoring programme. A post-harvest crop destruction ordinance and occasional use of pheromones as disruptants were the only other factors used by programme management, except in 1990. In 1990, the programme used a conventional insecticide on 280 acres (113 ha) out of 1.18 million acres (477,546 ha) of cotton. During the four year period 1986-1989, a management system was explored using a high rate pheromone disruption system and sterile insects. Major reductions in conventional insecticide usage, while maintaining extremely low populations, were evident in this semi-isolated valley of southern California. It is hoped that this will provide a model for a future large scale test on up to 20,000 acres (8100 ha) of cotton. (author). 11 ...
1993-09-01
Energy Technology Data Exchange (ETDEWEB)
We report the performance of a commercial recuperated micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The biomass producer gas, obtained by gasification at 850{sup o}C with air at atmospheric pressure, contains about 7% H2, 17% CO, 15% CO2, 4% CH4, 2% other hydrocarbons, 2% H2O, and a balance of N2 and Ar from air. It has a net heating value of about 6 MJ/(Nm{sup 3}). The micro gas turbine delivers full power (30 kW{sub e}) on gas mixtures with a net heating value of at least 15 MJ/(Nm{sup 3}). For gas of lower heating value, the maximum fuel gas flow allowed by the fuel control unit limits the attainable power. At reduced power, the lower limit for stable operation is a net heating value of about 8 MJ/(Nm{sup 3}). The gross efficiency of the micro gas turbine depends on the output power but not on the gas heating value, within our estimated measurement accuracy of about 2%. Above 70% of full ...
2007-08-15
Beneficiation-hydroretort processing of US oil shales, engineering study
Energy Technology Data Exchange (ETDEWEB)
This report describes a beneficiation facility designed to process 1620 tons per day of run-of-mine Alabama oil shale containing 12.7 gallons of kerogen per ton of ore (based on Fischer Assay). The beneficiation facility will produce briquettes of oil shale concentrate containing 34.1 gallons of kerogen per ton (based on Fischer Assay). The beneficiation facility will produce briquettes of oil shale concentrate containing 34.1 gallons of kerogen per ton (based on Fischer Assay) suitable for feed to a hydroretort oil extraction facility of nominally 20,000 barrels per day capacity. The beneficiation plant design prepared includes the operations of crushing, grinding, flotation, thickening, filtering, drying, briquetting, conveying and tailings empoundment. A complete oil shale beneficiation plant is described including all anticipated ancillary facilities. For purposes of determining capital and operating costs, the beneficiation facility is ...
1988-12-01
Mass distribution of fission products in the 28.5 MeV alpha particle induced fission of "2"3"2Th
International Nuclear Information System (INIS)
Mass distribution in 28.5 MeV alpha particle induced fission of "2"3"2Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of "2"3"5U. (orig.).
Mass distribution of fission products in the 28. 5 MeV alpha particle induced fission of sup 232 Th
Energy Technology Data Exchange (ETDEWEB)
Mass distribution in 28.5 MeV alpha particle induced fission of {sup 232}Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of {sup 235}U. (orig.).
1989-01-01
Isomeric island in the vicinity of 66Fe
An island of isomers have recently been observed on both sides of the N=40 shell below the Ni isotopes. Isomeric states in the 65Fe and 67Fe allow the knowledge of the single particle structure around the {nu}g9/2 shell. Moreover, the excitation energy of the first 2+ and 4+ states in the 68Fe have been established by {beta}-{gamma} correlation. The evolution of the structure of the Fe isotopes going far away from the valley of stability is, for the first time, given for N>40.
2006-04-26
Isomeric island in the vicinity of 66Fe
International Nuclear Information System (INIS)
An island of isomers have recently been observed on both sides of the N=40 shell below the Ni isotopes. Isomeric states in the 65Fe and 67Fe allow the knowledge of the single particle structure around the #nu#g9/2 shell. Moreover, the excitation energy of the first 2+ and 4+ states in the 68Fe have been established by #beta#-#gamma# correlation. The evolution of the structure of the Fe isotopes going far away from the valley of stability is, for the first time, given for N>40.
2006-04-26
High-level waste tank modifications, installation of mobilization equipment/check out
Energy Technology Data Exchange (ETDEWEB)
PUREX high-level waste (HLW) is contained at the West Valley Demonstration Project (WVDP) in an underground carbon-steel storage tank. The HLW consists of a precipitated sludge and an alkaline supernate. This report describes the system that the WVDP has developed and implemented to resuspend and wash the HLW sludge from the tank. The report discusses Sludge Mobilization and Wash System (SMWS) equipment design, installation, and testing. The storage tank required modifications to accommodate the SMWS. These modifications are discussed as well.
1992-08-31
Energy Technology Data Exchange (ETDEWEB)
Airborne fine particle sulfur data from the summer intensive of Project MOHAVE (Measurement of Haze and Visual Effects) was analyzed by the Receptor Model Applied to Patterns in Space (RMAPS) model, a novel multivariate receptor-oriented model that applies to secondary and primary species. The sulfur data from 17 sites were found to be well predicted by three spatial patterns interpreted as sources along the valley of the Colorado River (including the large Mohave coal-fired power plant, a smaller power plant and the city of Las Vegas); transport from sources located to the southwest; and transport from sources located to the southeast. The model was tested by using parameters derived from the 17-site data set to apportion sulfur for six sites that were not part of the original data set. The sulfur apportionment for these site sites was in agreement with the original apportionment and the physical interpretation of the spatial patterns given above. The effects of ...
1997-02-01
Quaternary tilt of Death Valley determined from landform modelling of alluvial fans
Energy Technology Data Exchange (ETDEWEB)
Alluvial fans along the east side of central Death Valley are being actively back-tilted along the Death Valley fault zone. Initial modelling of the Copper Canyon and Furnace Creek fans led to recognition of distinct segments. Field reconnaissance and aerial photo mapping were conducted to check model results and improve segment discrimination. Surface roughness, relative position, vegetation distribution, and drainage patterns provided independent evidence for segment discrimination. Subsequent modelling of individual segments produced a range of tilt values from 0.275[degree] to 0.559[degree] down to the northeast. Continued analysis of these fan segments is concentrated on: (1) assigning confidence and error values to the tilt values; and (2) dating individual segments. Further work will compare the tilt rates of east-side fans with those from the west. The mean squared error (MSE) is currently being used as a first order assessment of the ...
1993-04-01
Origin of salinity in produced waters from the Palm Valley gas field, Northern Territory, Australia
Energy Technology Data Exchange (ETDEWEB)
The chemical composition and evolution of produced waters associated with gas production in the Palm Valley gas field, Northern Territory, has important implications for issues such as gas reserve calculations, reservoir management and saline water disposal. The occurrence of saline formation water in the Palm Valley field has been the subject of considerable debate. There were no occurrences of mobile water early in the development of the field and only after gas production had reduced the reservoir pressure, was saline formation water produced. Initially this was in small quantities but has increased dramatically with time, particularly after the initiation of compression in November 1996. The produced waters range from highly saline (up to 300,000 mg/L TDS), with unusual enrichments in Ca, Ba and Sr, to low salinity fluids that may represent condensate waters. The Sr isotopic compositions of the waters ({sup 87}Sr/{sup 86}Sr = 0.7041-0.7172) ...
2005-04-01
Origin of salinity in produced waters from the Palm Valley gas field, Northern Territory, Australia
International Nuclear Information System (INIS)
The chemical composition and evolution of produced waters associated with gas production in the Palm Valley gas field, Northern Territory, has important implications for issues such as gas reserve calculations, reservoir management and saline water disposal. The occurrence of saline formation water in the Palm Valley field has been the subject of considerable debate. There were no occurrences of mobile water early in the development of the field and only after gas production had reduced the reservoir pressure, was saline formation water produced. Initially this was in small quantities but has increased dramatically with time, particularly after the initiation of compression in November 1996. The produced waters range from highly saline (up to 300,000 mg/L TDS), with unusual enrichments in Ca, Ba and Sr, to low salinity fluids that may represent condensate waters. The Sr isotopic compositions of the waters ("8"7Sr/"8"6Sr = 0.7041-0.7172) are ...
2005-04-01
Visual recovery after vitrectomy for macular hole using 25-gauge instruments
British Library Electronic Table of Contents (United Kingdom)
Abstract. Purpose: To determine whether vitrectomy with 25-gauge instruments contributes to better postoperative visual recovery after macular hole (MH) surgery. Methods: The medical records for 46 consecutive eyes operated for MH by a single surgeon were retrospectively examined. Vitrectomy had been performed with a 25-gauge instrument in 23 eyes (25-G group) and with a 20-gauge instrument in 23 eyes (20-G group). Postoperative visual acuity (VA) in logMAR (logarithm of the minimum angle of resolution) units after 1 week and 1, 3, 6, 9 and 12 months, operating time, and volume of intraocular irrigating fluid were compared between the two groups. Results: Mean preoperative logMAR VA was 0.72 in the 25-G group and 0.68 in the 20-G group (p = 0.282, unpaired t-test). One week after surgery, ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Improvements to a small diesel engine turbocharger were made based on data gathered during a previous Army contract. The improved turbocharger was fabricated and tested on a small, four cylinder, 239 CID diesel engine. Engine dynamometer test data revealed a 2 to 9 percent reduction in fuel consumption at all points over the operating envelope. A turbocharger was operated for 1011 hours at speeds between 70000 and 78000 rpm without incident. The ball bearings were in excellent condition at the end of the test. A math model of the engine and turbocharger was generated. The model was used to estimate 13 Mode Federal Diesel Emissions Cycle, the LA4 driving cycle and the application of the variable area turbine nozzle (VATN) turbocharger to a diesel engine driven generator set. A recommendation was made to build a gen set demo unit. A fuel savings of 8 to 10 percent was estimated for a 30KW DED generator set.
1982-04-01
Energy Technology Data Exchange (ETDEWEB)
Our latest survey of hydro resources demonstrates the significant role that hydroelectric power continues to play in world energy supply. Our statistics have been revised, updated and expanded this year (1992) on the basis of a detailed questionnaire sent to power authorities around the world. For cases where data could not be obtained in this way we have collaborated with the World Energy Council, the United Nations and OLADE. The four tables this year give data by country and geographical region for the following: 1. Hydropower potential: a detailed breakdown of gross theoretical, technically feasible and economically feasible hydro potential, as well as the dates when the figures were last evaluated. 2. Hydro capacity in operation, under construction and planned (pure hydro only excluding contributions derived from pumped storage). 3. Hydropower ownership: data on public versus independent producers. 4. Pumped-storage plants: in ...
1992-08-01
The effect of particle inlet conditions on FCC riser hydrodynamics and product yields.
Energy Technology Data Exchange (ETDEWEB)
Essential to today's modern refineries and the gasoline production process are fluidized catalytic cracking units. By using a computational fluid dynamics (CFD) code developed at Argonne National Laboratory to simulate the riser, parametric and sensitivity studies were performed to determine the effect of catalyst inlet conditions on the riser hydrodynamics and on the product yields. Simulations were created on the basis of a general riser configuration and operating conditions. The results of this work are indications of riser operating conditions that will maximize specific product yields. The CFD code is a three-dimensional, multiphase, turbulent, reacting flow code with phenomenological models for particle-solid interactions, droplet evaporation, and chemical kinetics. The code has been validated against pressure, particle loading, and product yield measurements. After validation of the code, parametric studies ...
1999-10-11
The effect of H_2S on molten carbonate fuel cells
International Nuclear Information System (INIS)
Although molten carbonate fuel cells (MCFC) have been under development since the late 1950s, the operating characteristics with gases derived from coal containing a wide range of elements other than C, H, and O were not studied until the Energy Conversion Alternative Study (ECAS) was completed in the late 1970s. Since then, the work of each contractor (United Technologies, Institute of Gas Technology, General Electric, and Energy Research Corporation) has included some contaminant studies (primarily of sulfur compounds). The majority of the reported work appears to have been conducted by UTC and IGT. The results indicate that the MCFC requires removal of sulfur to ppm levels. However, because of the strong dependence on temperature, pressure, gas composition, gas utilization, cell components, and system operation (i.e. recycle, venting, gas cleanup), the tolerance limits can vary widely.
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is strongly affected by the saline water ...
2004-05-01
International Nuclear Information System (INIS)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is strongly affected by the saline water ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is strongly affected by the saline water ...
2004-05-01
Safety assessment of South White Rose expansion project
Energy Technology Data Exchange (ETDEWEB)
Husky Oil Operations Ltd (Husky) is considering the development of the South White Rose Expansion (SWRX) area, located approximately 4 km south of the current Southern Glory Hole (SGH) in approximately 120 m of water. Within the new glory hole, one new drill centre will be constructed with wells tied back and into the SGH manifolds. The SWRX drill centre will comprise three horizontal production wells and two horizontal water injection wells with expansion capacity for eight wells. Husky is intending to submit a Development Plan Amendment to the Canada-Newfoundland and Labrador Offshore Petroleum Board (C-NLOPB) as part of the development. This document presented the results of a study that assessed the potential impact of the new development on existing White Rose safety studies. The study reviewed existing safety studies that were developed for the White Rose project to determine the potential impact of the new SWRX development. These studies included Mobile ...
2006-10-05
Energy Technology Data Exchange (ETDEWEB)
This report is an overview of Pacific Northwest Laboratory's (PNL) research on how hydroelectric generation affects aquatic biota and environments. The major accomplishments of this research are described, and additional work needed to permit optimal use of available data is identified. The research goals are to: (1) identify impacts of hydroelectric generation, (2) provide guidance in allocating scarce water resources, and (3) develop techniques to avoid or reduce the impacts on aquatic communities or to compensate for unavoidable impacts. Through laboratory and field experiments, an understanding is being developed of the generic impacts of hydrogeneration. Because PNL is located near the Columbia River, which is extensively developed for hydroelectric generation, it is used as a natural laboratory for studying a large-scale operating system. Although the impacts studied result from a particular system of dams and operating ...
1981-05-01
Report two. Safety offshore eastern Canada. Summary of studies and seminars
Energy Technology Data Exchange (ETDEWEB)
In 1982 the semi-submersible drilling unit Ocean Ranger capsized and sank off the Grand Banks, resulting in the loss of the entire 84-man crew. A Royal Commission was set up to conduct an enquiry into the incident, and to carry out a process of research and opinion-gathering towards providing recommendations to both federal and Newfoundland governments. The primary purpose of the Commission was to determine why the Ocean Ranger sank, why none of the crew were saved, and how to avoid similar disasters. A number of studies and seminars were held to focus expert knowledge and opinion in several key fields and to update studies and fill gaps in the data base. Summaries of selected study reports and the seminar proceedings are presented in the following areas: the environment, including ice, marine climatology, weather forecasting services, wave climatology, oceanographic information, and seabed information; design, including mobile offshore drilling rig design ...
1984-05-01
Remedial Design/Remedial Action Work Plan for Operable Units 6-05 and 10-04, Phase IV
Energy Technology Data Exchange (ETDEWEB)
This Phase IV Remedial Design/Remedial Action Work Plan addresses the remediation of areas with the potential for UXO at the Idaho National Laboratory. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. Five areas within the Naval Proving Ground that are known to contain UXO include the Naval Ordnance Disposal Area, the Mass Detonation Area, the Experimental Field Station, The Rail Car Explosion Area, and the Land Mine Fuze Burn Area. The Phase IV remedial action will be concentrated in these five areas. For other areas, such as the Arco High-Altitude Bombing Range and the Twin Buttes Bombing Range, ordnance has largely consisted of sand-filled practice bombs that do not pose an explosion risk. Ordnance encountered in these areas will be addressed under the Phase I Operations and Maintenance Plan that allows for the recovery and disposal of ordnance that poses an imminent risk to human ...
2006-11-14
Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying out the base of the ...
1984-01-01
Oil shale today : thoughts on why the majors stay away
Energy Technology Data Exchange (ETDEWEB)
This article discussed potential reasons why most major oil companies are not currently investing in oil shale resources. At present, only Shell, Chevron-Texaco, and ExxonMobil are engaged in oil shale pilot schemes. It was suggested that one of the reasons oil companies are reluctant to become involved is due to weak responses to experimental leasing programs conducted by the federal government of the United States, which are not favourable for commercial-scale operations. A federally sponsored leasing program and clear unconventional resource energy policies are needed, and unconventional oil resources must be developed in order to prevent escalating oil prices. The economics of oil shale recovery are equivalent to those obtained by Alberta's oil sands operators. Large amounts of char and hydrogen in the oil shale add value. However, oil shale processing has significant environmental impacts. Major oil companies ...
2008-07-15
Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems
Energy Technology Data Exchange (ETDEWEB)
Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. (Author).
1992-11-01
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional mathematical model has been developed as a tool for furnace structure design and operation conditions optimization when the straw combustion is in oxygen-enriched or conventional air atmospheres. Mathematical methods have been used based on a combination of FLIC (A fluid Dynamic Incinerator Code) code for the in-bed incineration and commercial software FLUENT for the over-bed combustion. Oxygen-enriched atmospheres promote the destruction of most pollutants due to the high oxygen partial pressures and temperatures, which is reflected by very low residual amounts of organic combustion by-products in the bottom ash and flue gas of the straw-fired boiler unit. The predictions indicated that the maximum combustion temperature is around 1500 K, CO emission is 201 vppm and O{sub 2} concentration is about 6.9 vol% at furnace exit, and it is shown that mathematical models can serve as a reliable tool for detailed analysis of straw ...
2010-05-15
Long-term corrosion study at nuclear power plant Bohunice (Slovakia)
International Nuclear Information System (INIS)
Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original 'Bohunice' design in period 1994-1998. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Moessbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Moessbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filter deposits. The corrosion of new feed water pipelines system (from austenitic steel) in combination to innovated operation regimes goes dominantly to magnetite. The hematite presence is mostly on the internal surface of steam generator body and its concentration increases towards the top of the body. In the results ...
2010-03-01
Large temperature differential thermal storage system. Its design and evaluation
Energy Technology Data Exchange (ETDEWEB)
A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
For developing coal liquefaction processes, it is an important problem to improve the light oil yield with increased oil yield. It was previously reported that distillate mainly containing lighter fraction can be produced with high oil yield by reducing the iron/sulfur catalyst addition in slurry, by recycling gas in the process operation, by utilizing these effects, and by using heavy oil as recycling solvent. In this study, the maximum distillate yield of Victorian brown coal was investigated through continuous liquefaction using a bench scale unit. In addition, operation conditions for obtaining sufficient oil yield were investigated under the reduced catalyst addition into one-third. Consequently, it was confirmed that the maximum content of lighter fraction in distillate product was obtained with reduced catalyst addition by using heavy oil as recycling solvent, by adopting new catalyst, and by utilizing effects of CLB ...
1996-10-28
Hybrid solution and pump-storage optimization in water supply system efficiency: A case study
International Nuclear Information System (INIS)
Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity tariff, for a pumped storage system with water consumption and inlet discharge. Wind ...
2008-11-01
Evolutionary developments advancing the floating production, storage, and offloading concept
Energy Technology Data Exchange (ETDEWEB)
Tanker-based floating production, storage, and offloading (FPSO) systems have been in operation since Aug. 1977, when a single-well FPSO facility was put into production by Shell Espana in the Mediterranean. The overall operational experience with this system at this field is reviewed, with special attention to the wireline workover facilities, which have proved very satisfactory. A subsequent evolutionary step, a FPSO system accommodating multiple wells, necessitated development of a multibore fluid swivel. A design program for this swivel was initiated in 1978; a prototype was built and full-scale testing finalized in 1980. A summary of the test results is presented. Simultaneously with the multibore swivel development, detailed engineering for an eight-well FPSO unit was begun. This system includes gas-lift and water injection capabilities. Provisions for through-flowline (TFL) well workover can be incorporated. The ...
1983-04-01
Advanced Fuel/Cladding Testing Capabilities in the ORNL High Flux Isotope Reactor
Energy Technology Data Exchange (ETDEWEB)
The ability to test advanced fuels and cladding materials under reactor operating conditions in the United States is limited. The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and the newly expanded post-irradiation examination (PIE) capability at the ORNL Irradiated Fuels Examination Laboratory provide unique support for this type of advanced fuel/cladding development effort. The wide breadth of ORNL's fuels and materials research divisions provides all the necessary fuel development capabilities in one location. At ORNL, facilities are available from test fuel fabrication, to irradiation in HFIR under either thermal or fast reactor conditions, to a complete suite of PIEs, and to final product disposal. There are very few locations in the world where this full range of capabilities exists. New testing capabilities at HFIR have been developed that allow testing of advanced nuclear fuels and cladding materials ...
2009-09-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this research project is to demonstrate sensing, communication, information and control technologies to achieve a seamless integration of multivendor distributed energy resource (DER) units at aggregation levels that meet individual user requirements for facility operations (residential, commercial, industrial, manufacturing, etc.) and further serve as resource options for electric and natural gas utilities. The fully demonstrated DER aggregation system with embodiment of communication and control technologies will lead to real-time, interactive, customer-managed service networks to achieve greater customer value. Work on this Advanced Communication and Control Project (ACCP) consists of a two-phase approach for an integrated demonstration of communication and control technologies to achieve a seamless integration of DER units to reach progressive levels of aggregated power output. Phase I involved design ...
2008-09-30
A preliminary stage configuration for a low pressure nuclear thermal rocket (LPNTR)
Energy Technology Data Exchange (ETDEWEB)
A low pressure nuclear thermal rocket (LPNTR) is configured to meet the requirements of a nuclear stage for manned Mars exploration. Safety, reliability and performance are given equal consideration in selecting the stage configuration. Preliminary trade studies are conducted to size the engine thrust and determine the thrust chamber pressure. A weight breakdown and mechanical configuration for the selected LPNTR concept are defined. A seven engine stage configuration is selected which gives a two engine out capability and eliminates the need for engine gimbaling. The stage can be ground assembled and launched as a unit including tankage for trans Earth injection and Earth orbital capture. The tankage is configured to eliminate the need for an inert shield. The small engine will be cheaper to develop than a single engine providing full thrust, and will be compatible with stages for Earth orbital, Lunar and deep space missions. Mission analyses are presented with ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The waste tail gas fuel emitted from refinery plant in Taiwan e.g. catalytic reforming unit, catalytic cracking unit and residue desulfurization unit, was recovered and reused as a replacement fuel. In this study, it was slowly added to the fuel stream of a heater furnace to replace natural gas for powering a full-scale distillation process. The waste tail gas fuel contained on average 60 mol% of hydrogen. On-site experimental results show that both the flame length and orange-yellowish brightness decrease with increasing proportion of waste gas fuel in the original natural gas fuel. Moreover, the adiabatic flame temperature increases as the content of waste gas fuel is increased in the fuel mixture since waste gas fuel has a higher adiabatic flame temperature than that of natural gas. The complete replacement of natural gas by waste gas fuel for a heater furnace operating at 70% loading (i.e. 3.6 x ...
2010-02-15
Direct liquefaction Proof-of-Concept facility. Final technical progress report
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of work which included extensive modifications to HRI`s existing 3 ton per day Process Development Unit (PDU) and completion of the first PDU run. The 58-day Run 1 demonstrated scale-up of the Catalytic Two-Stage Liquefaction (CTSL Process) on Illinois No. 6 coal to produce distillate liquid products at a rate of up to 5 barrels per to of moisture-ash-free coal. The Kerr McGee Rose-SR unit from Wilsonville was redesigned and installed next to the US Filter installation to allow a comparison of the two solids removal systems. Also included was a new enclosed reactor tower, upgraded computer controls and a data acquisition system, an alternate power supply, a newly refurbished reactor, an in-line hydrotreater, interstage sampling system, coal handling unit, a new ebullating pump, load cells and improved controls and remodeled preheaters. Distillate liquid yields of 5 barrels/ton of moisture ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
This thesis examines the design of a propulsion system for a series hybrid vehicle and includes the study of an energy storage unit using double-layer capacitors and a lightweight soft-switched converter system, and two new components in series hybrid vehicles. The development of environmentally sustainable vehicles is more urgent now given the fact that pollution levels are ever increasing. No electric vehicle has yet been developed that can compete with a normal vehicle based only on internal combustion engines. The dilemma lies in the difficulty of storing the amount of energy needed and supply it a high power levels. An attractive and viable option to reducing pollution and maintaining good performance may lie in hybrid electric-powered vehicles. The double-layer power capacitors are an interesting option because of their high power density and long lifetime. The devices are new and assembling large energy storage units must be thoroughly ...
2001-07-01
A CANDU-6 versus ACR-1000 SDS1 performance comparison during some LOCA scenarios
International Nuclear Information System (INIS)
According to the Romanian Nuclear Strategy, the third and fourth units of the Cernavoda NPP will be commissioned by 2015. Improvements in operation and safety are expected to be applied for these CANDU-6 based units. On the other side, the need for innovation determined AECL to promote the ACR -1000 - an evolutionary Generation III+ power reactor design and a necessary step towards Generation IV inherently safe nuclear energy systems. CANDU-6 is recognized for having two independent fully capable shutdown systems. ACR-1000 also benefits for this strong safety feature. Two major achievements i.e. using of light water as coolant and using Low Enriched Uranium (LEU) as fuel in a compact heavy water moderated lattice allowed the obtaining of a slightly negative Coolant Void Reactivity (CVR) for the first time in a CANDU-type reactor. The main goal of the paper is to compare the response of SDS1 action during some LOCAs supposed ...
2009-10-12
Energy Technology Data Exchange (ETDEWEB)
With the aid of a DOE grant (No. DE-FC26-01NT41050), Stolar Research Corporation (Stolar) developed the Horizon Sensor (HS) to distinguish between the different layers of a coal seam. Mounted on mining machine cutter drums, HS units can detect or sense the horizon between the coal seam and the roof and floor rock, providing the opportunity to accurately mine the section of the seam most desired. HS also enables accurate cutting of minimum height if that is the operator's objective. Often when cutting is done out-of-seam, the head-positioning function facilitates a fixed mining height to minimize dilution. With this technology, miners can still be at a remote location, yet cut only the clean coal, resulting in a much more efficient overall process. The objectives of this project were to demonstrate the feasibility of horizon sensing on mining machines and demonstrate that Horizon Sensing can allow coal to be cut cleaner and more ...
2003-03-18
Video equipment of tele dosimetry and audio
International Nuclear Information System (INIS)
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric ...
2007-07-01
The case of nuclear power: an economical analysis
Energy Technology Data Exchange (ETDEWEB)
In this paper an analysis will be performed to assess the economical competitiveness of Nuclear Power against other base load technologies. There are several plans to build more nuclear power plants in western countries; these plans are result among other things of the fossil fuel high prices and the concern for the global warming. France started the construction of one EPR at Flamanville in 2007 and at the end of 2008 there were 17 applications before NRC for construction and operation licenses (COL) to build as much as 26 new reactor units in USA, among the designs selected are the US-EPR, APWR, ESBWR, ABWR and AP1000. Currently, there is a lot of uncertainty about what is the overnight cost for a new generation III nuclear power plant and the vendors are not providing too much information. However, it is expected that under the new economy conditions the overnight cost will be between 2500 and 3500 USD/kW, the output electricity power of the ...
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
The Burrard Thermal Generating Station is located at Port Moody, British Columbia, and burns natural gas to supply steam to six turbine units for generating up to 912 MW of electricity. The Burrard plant accounts for ca 8.7% of the provincial generating capability. Burrard is expected to continue to fill a vital role as a supplier of displaceable firm energy to the British Columbia Hydro system. In parallel with a renewed focus on Burrard from a system planning perspective, there have also been concerns about air pollution from the plant in the context of its possible effect on the region's air quality. To address this and other issues surrounding Burrard's future, B.C. Hydro established a project team to conduct a utilization study. The team's work focused on the role of Burrard in providing a reliable and profitable role in electricity generation, the options for dealing with the air quality issue, and the implications of choosing one ...
1993-01-01
Survey of light-water-reactor designs to be offered in the United States
Energy Technology Data Exchange (ETDEWEB)
ORNL has conducted a Nuclear Power Options Viability Study for the Department of Energy. That study is primarily concerned with new technology which could be developed for initial operation in the 2000 to 2010 time frame. Such technology would have to compete not only with coal options but with incrementally improved commercial light-water-reactors. This survey reported here was undertaken to gain an understanding of the nuclear commercial technology likely to be offered in the late 1980s and perhaps beyond. The three US vendors actively marketing NSSSs are each developing a product for the future which they expect to be more reliable, more maintainable, more economical, and safer than the present plants. These are all essentially 3800-MW(t) designs, although all are studying smaller plants. They apparently will be off offered as standard prelicensed designs with much larger scope than earlier NSSS offerings, with the possibility of firm prices. Westinghouse with ...
1986-03-01
Strontium removal from caustic carbonate waste solutions using carrier coprecipitation
Energy Technology Data Exchange (ETDEWEB)
A carrier coprecipitation procedures has been developed for the removal of radioactive strontium from caustic liquid low-level waste (LLLW) generated at Oak Ridge National Laboratory. The two-step treatment process involves the addition of normal Sr (as SrCl{sub 2}) to the waste matrix, which is composed primarily of 0.3 M NaOH and 0.6 M Na{sub 2}CO{sub 3}. The active Sr equilibrates with the normal Sr carrier and coprecipitates as SrCO{sub 3} at pH 13. A liquid/solid separation is made before the pH of the supernate is reduced to pH 8 with sulfuric acid. During the neutralization step, the aluminum is the waste precipitates as Al(OH){sub 3}. Further Sr decontamination is achieved as traces of active Sr sorb to the Al(OH){sub 3} that precipitates during the neutralization step. A final liquid/solid separation is made at pH 8 to remove the sorbed active Sr. Maximum Sr decontamination of the LLLW is obtained when at least 50 ppm normal Sr is added to the waste. Because formation of the ...
1994-12-31
Selection of melter systems for the DOE/Industrial Center for Waste Vitrification Research
Energy Technology Data Exchange (ETDEWEB)
The EPA has designated vitrification as the best developed available technology for immobilization of High-Level Nuclear Waste. In a recent federal facilities compliance agreement between the EPA, the State of Washington, and the DOE, the DOE agreed to vitrify all of the Low Level Radioactive Waste resulting from processing of High Level Radioactive Waste stored at the Hanford Site. This is expected to result in the requirement of 100 ton per day Low Level Radioactive Waste melters. Thus, there is increased need for the rapid adaptation of commercial melter equipment to DOE`s needs. DOE has needed a facility where commercial pilot scale equipment could be operated on surrogate (non-radioactive) simulations of typical DOE waste streams. The DOE/Industry Center for Vitrification Research (Center) was established in 1992 at the Clemson University Department of Environmental Systems Engineering, Clemson, SC, to address that need. This report discusses some of the ...
1993-12-31
Real-time neutron radiography at Texas A and M University
Energy Technology Data Exchange (ETDEWEB)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
1990-12-20
Real-time neutron radiography at Texas A and M University
International Nuclear Information System (INIS)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
1990-12-01
Harvesting operations and energetics of tall grasses for biomass energy production: a case study
Energy Technology Data Exchange (ETDEWEB)
Florida imports about 85% of its energy needs. Among the renewable energy sources available, biomass appears promising in Florida because of a favourable environment for production and the available methods to convert biomass to energy. Optimal production of biomass requires the identification and management of high yielding persistent perennial cultivars. Elephantgrass (Pennisetum purpureum Schum.) and energycane (Saccharum spontaneum L.) are two tall grasses that meet these requirements. To optimize the supply of convertible biomass, suitable methods of harvesting the crop must be available. The purpose of this research was to study the feasibility and energetics of harvesting, drying and baling tall grasses with conventional farm machinery. A Mathews rotary scythe and a New Holland 849 Auto Wrap large round baler were determined to provide a practical harvesting system for baled biomass averaging 15-27 Mg ha [sup -1]. This harvesting system requires about 3 kg diesel fuel Mg [sup ...
1992-01-01
Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66{approx}8.91 x 1025 n/m{sup 2}) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4{approx}6 times faster DHC velocity(5.298E-0.8{approx}7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was ...
2003-10-01
Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube
International Nuclear Information System (INIS)
The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66#approx#8.91 x 1025 n/m"2) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4#approx#6 times faster DHC velocity(5.298E-0.8#approx#7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen ...
2003-10-01
A Preliminary Study for the Analysis of PSA Success Criteria for Kori Units 3 and 4
Energy Technology Data Exchange (ETDEWEB)
This paper identifies the event sequences that require thermal-hydraulic analyses for the success criteria of probabilistic safety analysis (PSA). The selection of the sequences is performed based on the review of the NEI Peer Review Process Guidance and ASME PRA Standard. Success criteria are the important element of PSA quality. Success criteria decide the success or failure of the key function in the PSA event tree. It is defined as a minimum set of components/trains of system required to mitigate an accident. Thermal-hydraulic codes are generally used to derive time-related criteria in the PSA, such as operator action time used in human reliability analysis (HRA), event timing, and time to recover the component or the power. This paper suggests the use of the MARS code for the T-H analysis to obtain the success criteria and sequence timing, and operator action time. In the Kori Units 3 and 4 PSA report, the T-H analyses ...
2009-10-15
A Preliminary Study for the Analysis of PSA Success Criteria for Kori Units 3 and 4
International Nuclear Information System (INIS)
This paper identifies the event sequences that require thermal-hydraulic analyses for the success criteria of probabilistic safety analysis (PSA). The selection of the sequences is performed based on the review of the NEI Peer Review Process Guidance and ASME PRA Standard. Success criteria are the important element of PSA quality. Success criteria decide the success or failure of the key function in the PSA event tree. It is defined as a minimum set of components/trains of system required to mitigate an accident. Thermal-hydraulic codes are generally used to derive time-related criteria in the PSA, such as operator action time used in human reliability analysis (HRA), event timing, and time to recover the component or the power. This paper suggests the use of the MARS code for the T-H analysis to obtain the success criteria and sequence timing, and operator action time. In the Kori Units 3 and 4 PSA report, the T-H analyses ...
2009-10-01
Waste management units - Savannah River Site. Volume 1, Waste management unit worksheets
Energy Technology Data Exchange (ETDEWEB)
This report is a compilation of worksheets from the waste management units of Savannah River Plant. Information is presented on the following: Solid Waste Management Units having received hazardous waste or hazardous constituents with a known release to the environment; Solid Waste Management Units having received hazardous waste or hazardous constituents with no known release to the environment; Solid Waste Management Units having received no hazardous waste or hazardous constituents; Waste Management Units having received source; and special nuclear, or byproduct material only.
1989-10-01
Production capabilities in US nuclear reactors for medical radioisotopes
Energy Technology Data Exchange (ETDEWEB)
The availability of reactor-produced radioisotopes in the United States for use in medical research and nuclear medicine has traditionally depended on facilities which are an integral part of the US national laboratories and a few reactors at universities. One exception is the reactor in Sterling Forest, New York, originally operated as part of the Cintichem (Union Carbide) system, which is currently in the process of permanent shutdown. Since there are no industry-run reactors in the US, the national laboratories and universities thus play a critical role in providing reactor-produced radioisotopes for medical research and clinical use. The goal of this survey is to provide a comprehensive summary of these production capabilities. With the temporary shutdown of the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) in November 1986, the radioisotopes required for DOE-supported radionuclide generators were made available at ...
1992-11-01
Preparing for drilling operations in a harsh environment
Energy Technology Data Exchange (ETDEWEB)
The Eiric Raude offshore drilling rig is a powerful machine that is suitable for drilling in harsh environments in ultra deep water. It has a total drilling depth of 8,200 to 10,000 metres and an operational displacement of 53,400 mt. The rig complies with the regulatory regimes of Norway, the United Kingdom and Canada. The Eiric Raude has drilled 5 deepwater wells offshore eastern Canada, 1 well offshore Cuba, 1 well west of Shetland, and 3 offshore Norway. The environmental criteria for extreme weather conditions consider wave, current and wind forces. The general operational guidelines were discussed along with key areas for prevention of environmental impact, including emissions from well testing, air emissions from diesel engines, cooling water, bunkering operations, discharges from drilling, accidental discharges, drain water, and domestic sewage. It was noted that the zero discharge philosophy is ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Statoil is operating an increasing number of offshore and onshore pipelines in the North Sea area and elsewhere. Cathodic protection is a significant part of the corrosion management for these lines and we have collected a significant amount of experience with respect to design and operation of the systems. This paper deals with our comprehensive program for the onshore cathodic protection systems and the various challenges in different countries with respect to technical matters, such as operating conditions and different terrain. Generally, the systems are based on automatically controlled rectifier systems with a wide range of current drainage and very comprehensive monitoring of potentials and current flowing. The use of coupons, polarisation cells and buried reference cells are essential, as well as the use of intensive measurements along the route. The use of online monitoring of selected test posts and all rectifier ...
1999-07-01
Efficient low-emission burners for natural gas domestic cooktops
Energy Technology Data Exchange (ETDEWEB)
Three new partially-aerated burners have been developed for Australian cooktops fired with natural gas, with maximum thermal inputs of 12, 7.5 and 5.5 MJ h{sup -1}. These novel burner designs minimise the NO{sub 2} emission per unit of useful energy, since NO{sub 2} is the more toxic nitrogen oxide of concern for indoor air pollution. They provide lower values of the ratio of NO{sub 2} emission to thermal efficiency than production burners, with respective reductions of 42, 13 and 23% compared with production burners of corresponding size. The traditional combustion diagrams of these prototype burners have been defined, on plots of primary aeration versus thermal input, to identify the regions of stable flame operation. However, the regions of satisfactory operation are further limited at low primary aeration by the Australian Gas Association requirement for CO/CO{sub 2} ratio <0.01 and at low thermal inputs by the ...
2000-03-01
Characterization of Single-Cylinder Small-Bore 4-Stroke CIDI Engine Combustion
Energy Technology Data Exchange (ETDEWEB)
Direct injection diesel engines power most of the heavy-duty vehicles. Due to their superior fuel economy, high power density and low carbon dioxide emissions, turbocharged, small bore, high speed, direct injection diesel engines are being considered to power light duty vehicles. Such vehicles have to meet stringent emission standards. However, it is difficult to meet these standards by modifying the in-cylinder thermodynamic and combustion processes to reduce engine-out emissions. After-treatment devices will be needed to achieve even lower emission targets required in the production engines to account for the anticipated deterioration after long periods of operation in the field. To reduce the size, mass and cost of the after-treatment devices, there is a need to reduce engine-out emissions and optimize both the engine and the aftertreatment devices as one integrated system. For example, the trade-off between engine-out NOx and PM, suggests that one of these ...
2005-11-30
UK PubMed Central (United Kingdom)
IntroductionTransfusion is a common treatment in pediatric intensive care units (PICUs). Studies in adults suggest that prolonged storage of red blood cell units is associated with...Full Text Available
2010-01-01
White Rose oilfield development application. CD-ROM ed.
Energy Technology Data Exchange (ETDEWEB)
Located approximately 350 km east of Newfoundland, on the eastern edge of the Jeanne d'Arc Basin, and approximately 50 km from both the Terra Nova and Hibernia oilfields, the White Rose oilfield is considered the main oil producing basin off the eastern coast of North America. Husky Oil is very active in the region and holds almost 32 per cent net working interest in the Significant Discovery License areas in the Jeanne d'Arc basin. The development of an economically significant oil discovery in the White Rose Significant Discovery Area is being proposed jointly by Husky Oil and Petro-Canada. It is estimated that the project would enable the recovery of an estimated 36 million cubic meters (230 million barrels) of recoverable oil in this area that covers approximately 40 square kilometers. The operators propose to use a ship-shaped floating production, storage and offloading (FPSO) facility which could store up to 135,000 cubic meters (850,000 ...
2001-01-01
... United States Forces Command, Detachment 13 ... EUCOM Headquarters Support Detachment 1 ... 7th Joint Task Force Augmentation Team ...
U.S. Fish and Wildlife Service Home
Lake Unit AL-05P, for public review and comment. These four CBRS units are located in Baldwin and Mobile Counties, Alabama. We invite the public to review and comment on the draft...
2011-09-14
International Nuclear Information System (INIS)
1973. 49 p. United States Belanger, BC USAEC Division of Applied
Costs of ambulatory care related to female pelvic floor disorders in the United States
UK PubMed Central (United Kingdom)
OBJECTIVETo evaluate trends in costs of ambulatory care related to female pelvic floor disorders (PFD) in the United States.STUDY DESIGNFull Text Available
2010-05-01
International Nuclear Information System (INIS)
As a continuation of its efforts to provide methodologies and tools to Member States to carry out comparative assessment and analyse priority environmental issues related to the development of the electric power sector, the IAEA has completed a new version of the Wien Automatic System Planning (WASP) Package WASP-IV for carrying out power generation expansion planning taking into consideration fuel availability and environmental constraints. This manual constitutes a part of this work and aims to provide users with a guide to use effectively the new version of the model WASP-IV. WASP was originally developed in 1972 by the Tennessee Valley Authority and the Oak Ridge National Laboratory in the USA to meet the IAEA needs to analyse the economic competitiveness of nuclear power in comparison to other generation expansion alternatives for supplying the future electricity requirements of a country or region. Previous versions of the model were used by Member States in ...
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
The Tennessee Valley Authority (TVA), the Electric Power Research Institute (EPRI), and the Department of Energy-National Energy Technologies Laboratory (DOE-NETL) are evaluating and demonstrating integration of terrestrial carbon sequestration techniques at a coal-fired electric power plant through the use of Flue Gas Desulfurization (FGD) system gypsum as a soil amendment and mulch, and coal fly ash pond process water for periodic irrigation. From January to March 2002, the Project Team initiated the construction of a 40 ha Carbon Capture and Water Emissions Treatment System (CCWESTRS) near TVA's Paradise Fossil Plant on marginally reclaimed surface coal mine lands in Kentucky. The CCWESTRS is growing commercial grade trees and cover crops and is expected to sequester 1.5-2.0 MT/ha carbon per year over a 20-year period. The concept could be used to meet a portion of the timber industry's needs while simultaneously sequestering carbon in lands ...
2005-08-30
Energy Technology Data Exchange (ETDEWEB)
The problem during the continuous idling operation of diesel engine is about the time increase in emission of HC (hydrocarbon which is not burned yet) into the atmosphere. A pilot injector having been developed, the time increase in HC emission was studied in order to ameliorate the combustion during the idling. An engine and spray unit were used with the above developed pilot injector for the experiment. Three types of injector were also used for the comparison purpose. Investigation was made of penetration characteristics of spray on the pump tester in the atmosphere, locally averaged droplet size distribution inside the spray, both droplet size and velocity distributions, and emission characteristics by the mounting test onto the engine. The developed pilot injector was most effective in controlling the HC emission. The time increase in HC emission is attributable to the adhering quantity of carbon. The adhering of carbon is caused by the ...
1992-10-01
Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies
Energy Technology Data Exchange (ETDEWEB)
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from the surface to the ...
1983-12-01
Review of KSNP LPSD PSA model based of ANS LPSD PRA standard, rev.0
Energy Technology Data Exchange (ETDEWEB)
Recently, under the de-regulation environment, nuclear industry has attempted various approaches to improve the economics of Nuclear Power Plants (NPP). One of these efforts is the Risk Informed/Performance-based Operation (RIPBO). This approach uses the risk and performance information to manage the resources effectively and efficiently that are used in the operation of NPP. In RIPBO, PSA quality is one of the most important things. The nuclear industry and regulatory body of U.S.A have developed a measure to evaluate the quality of PSA. NEI (Nuclear Energy Institute) has developed a guidance called 'NEI PRA Peer Review Guidance,' and NRC (Nuclear Regulatory Committee) and ASME have developed the 'PRA Standard.' In Korea, several projects are on going now, such as the extension of AOT/STI of RPS/ESFAS, Risk-informed In-service Inspection (RI-ISI). However, in Korea, there have been no attempts to evaluate ...
2004-02-01
NPOESS Interface Data Processing Segment (IDPS) Hardware
The National Oceanic and Atmospheric Administration (NOAA), Department of Defense (DoD), and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation weather and environmental satellite system; the National Polar-orbiting Operational Environmental Satellite System (NPOESS). NPOESS replaces the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA and the Defense Meteorological Satellite Program (DMSP) managed by the DoD. The NPOESS satellites carry a suite of sensors that collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere, and space. The NPOESS design allows centralized mission management and delivers high quality environmental products to military, civil and scientific users. The ground data processing segment for NPOESS is the Interface Data Processing Segment (IDPS), developed by Raytheon Intelligence and ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
In 1986, following comprehensive preliminary studies, a 17 MW battery energy storage plant was set up in the insular power supply system of Berlin (West) for the purpose of frequency and output control and provision of immediate reserve capacities. The present paper reports on the initial task, and the dimensioning and construction of this large-scale demonstration as well as the costs entailed in this. It also relates the experiences gained with the operation of the battery energy storage plant in its function as a fast-responding control unit and gives an account of its economic efficiency. Recent studies on the economic efficiency of the plant in conditions as they exist in the present interconnected power supply system are presented. Finally the author reports on the experiences gained with individual plant components, i.e., battery, battery periphery, and power converter and quantifies the cost of plant operation, ...
1996-12-31
An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)
International Nuclear Information System (INIS)
Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the third step the tritium is packaged for ...
2007-11-07
A field demonstration of the microbial treatment of sour produced water
Energy Technology Data Exchange (ETDEWEB)
The potential for detoxification and deodorization of sulfide-laden water (sour water) by microbial treatment was evaluated at a petroleum production site under field conditions. A sulfide-tolerant strain of the chemautotroph and facultative anaerobe, Thiobacillus denitrificans, was introduced into an oil-skimming pit of the Amoco Production Company LACT 10 Unit of the Salt Creek Field, Wyoming. Field-produced water enters this pit from the oil/water separation treatment train at an average flowrate of 5,000 bbl/D (795 m{sup 3}/D) with a potential maximum of 98,000 bbl/D (15,580 m{sup 3}/D). Water conditions at the pit inlet are 4,800 mg/l TDS, 100 mg/l sulfide, pH 7.8, and 107{degrees}F. To this water an aqueous solution of ammonium nitrate and diphosphorous pentoxide was added to provide required nutrients for the bacteria. The first 20% of the pit was aerated to a maximum depth of 5 ft (1.5 m) to facilitate the aerobic oxidation of sulfide. No provisions for pH ...
1995-12-31
International Nuclear Information System (INIS)
The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of monochromatic radiation ...
Hybrid Combined Cycles with Biomass and Waste Fired Bottoming Cycle - a Literature Study
Energy Technology Data Exchange (ETDEWEB)
Biomass is one of the main natural resources in Sweden. The present low-CO{sub 2} emission characteristics of the Swedish electricity production system (hydro and nuclear) can be retained only by expansion of biofuel applications for energy purposes. Domestic Swedish biomass resources are vast and renewable, but not infinite. They must be utilized as efficiently as possible, in order to make sure that they meet the conditions for sustainability in the future. Application of efficient power generation cycles at low costs is essential for meeting this challenge. This applies also to municipal solid waste incineration with energy extraction, which should be preferred to its dumping in landfills. Hybrid dual-fuel combined cycle units are a simple and affordable way to increase the electric efficiency of biofuel energy utilization, without big investments, uncertainties or loss of reliability arising from complicated technologies. Configurations of such power cycles are ...
2002-02-01
DEVELOPMENT OF TECHNOLOGIES AND ANALYTICAL CAPABILITIES FOR VISION 21 ENERGY PLANTS
Energy Technology Data Exchange (ETDEWEB)
The training of a new project team member was completed (Task 2.1). The Software Requirements Document was written (Task 2.3). It was determined that the CAPE-OPEN interfaces are sufficient for the communication between Fluent and V21 Controller (Task 2.4). The AspenPlus-Fluent prototype on allyl/triacetone alcohol production was further developed to assist the GUI and software design tasks. The prototype was also used to analyze the sensitivity of a process simulation result with respect to a parameter in a CFD model embedded in the process simulation. Thus the integration of process simulation and CFD provides additional process insights and enables the engineer to optimize overall process performance (e.g., product purity and yield) with respect to important CFD design and operation parameters (e.g., CSTR shaft speed). A top-level design of the V21 Controller was developed and discussed. A draft version of the Software Design Document was written (Task 2.5/2.6). ...
2001-07-10
Energy Technology Data Exchange (ETDEWEB)
This Corrective Action Investigation Plan contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 409 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 409 consists of three Corrective Action Sites (CASs): TA-53-001-TAB2, Septic Sludge Disposal Pit No.1; TA-53-002-TAB2, Septic Sludge Disposal Pit No.2; and RG-24-001-RGCR, Battery Dump Site. The Septic Sludge Disposal Pits are located near Bunker Two, close to Area 3, on the Tonopah Test Range. The Battery Dump Site is located at the abandoned Cactus Repeater Station on Cactus Peak. The Cactus Repeater Station was a remote, battery-powered, signal repeater station. The two Septic Sludge Disposal Pits were suspected to be used through the late 1980s as disposal sites for sludge from ...
2000-10-05
Three-dimensional elastic lidar winds
Energy Technology Data Exchange (ETDEWEB)
Maximum cross-correlation techniques have been used with satellite data to estimate winds and sea surface velocities for several years. Los Alamos National Laboratory (LANL) is currently using a variation of the basic maximum cross-correlation technique, coupled with a deterministic application of a vector median filter, to measure transverse winds as a function of range and altitude from incoherent elastic backscatter lidar data taken throughout large volumes within the atmospheric boundary layer. Hourly representations of three- dimensional wind fields, derived from elastic lidar data taken during an air-quality study performed in a region of complex terrain near Sunland Park, New Mexico, are presented and compared with results from an Environmental Protection Agency (EPA) approved laser doppler velocimeter. The wind fields showed persistent large scale eddies as well as general terrain following winds in the Rio Grande valley.
1996-07-01
Surface characteristics and overlaying properties of flat-pressed wood plastic composites
British Library Electronic Table of Contents (United Kingdom)
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The features of present deposits that form in the vicinity of hot springs can provide clues to the parameters of paleowaters in places of past hydrothermal activity marked by remnant carbonate and/or siliceous sinter. We investigated a large carbonate body at the Garga hot spring developing in the Baikal zone of nitric hydrotherms in the Barguzin Rift Zone valley. The main focus was on the structure of the carbonate mound, as well as on the partitioning of radioactive elements between the cyanobacterial mat and the inorganic component of the body (the issue that has never been explored before). The cyanobacterial community of the Garga spring is an active biosorbent of 226Ra, 228Ra, 210Pb. The radionuclides accumulated by biosorption become preserved in minerals that form within the bacter...
2011-01-01
Public power's roots deep in the Northwest
Energy Technology Data Exchange (ETDEWEB)
Municipal power systems developed early in the Pacific Northwest, but a new dimension was added in the 1930s when the public utility district (PUD) concept combining urban and rural areas encited vigorous debate and the public rejected private-utility candidates. A favorable national climate developed for consumer-owned systems during the 1920s and 30s encouraging the passage of the Federal Water Power Act, the creation of the Tennessee Valley Authority, the building of Hoover Dam, and the establishment of the Bonneville Power Administration. This article reviews developments following the Public Utility Act of 1935, which authorized the Federal Power Commission and the uniform system of accounts. After tracing the record of investigations and policy trends during the Roosevelt era, it concludes that utilities benefited from accounting regulations. (DCK)
1982-01-01
Plant maintenance and plant life extension issue, 2006
The focus of the March-April issue is on plant maintenance and plant life extension. Major articles/reports in this issue include: Spent fuel: myths and facts, by Jeffrey S. Merrifield, U.S. Nuclear Regulatory Commission; Critical pipe replacement procedure, by Geoff Gilmore, Climax Portable Machine Tools Inc.; Improving maintenance performance, by Larry Meyer and Joe Giuffre, DC Cook Nuclear Plant, American Electric Power; Equipment deficiency intolerance index, by Douglas F. Helms, Tennessee Valley Authority; Plant profile: I and C modernization at Dukovany, by Josef Rosol, CEZ Dukovany NPP, Czech Republic; and, Report: new plant activities.
2006-03-15
Mass distribution of fission products from moderately excited sup 236 U compound nucleus
Energy Technology Data Exchange (ETDEWEB)
The chain yields of 30 fission products were determined in 38 MeV {alpha}-particle induced fission of {sup 232}Th. The mass yield curve was found to be primarily asymmtric with a peak to valley (p/v) ratio of 3.5. A small peak has also been observed in the symmetric region. The observed p/v ratio has been resolved into the p/v ratios of the individual mass distributions of the possible fissioning isotopes of uranium formed as a result of multichance fission. An attempt has been made to explain the p/v ratios thus obtained in the light of the available excitation energy in the system. (orig.).
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The tests reported were part of the DOE Geothermal Reservoir Well Stimulation Program. This East Mesa (Imperial Valley, CA) well was successfully stimulated with two fracture treatments, a dendritic fracture and a planar fracture. The natural flow production of the well increased 114 percent, to 197,900 lb/hr. These tests were among the few successful attempts of this program to increase flow from geothermal production wells. The general belief is that these tests worked OK primarily because the formation was sedimentary rock (similar to rock in most oil and gas wells that have been stimulated successfully. Similar tests in geothermal hard rock reservoirs did not work very well. (DJE 2005)
1982-02-01
British Library Electronic Table of Contents (United Kingdom)
The erosion of rocks rich in organic matter typically leads to the complete mineralization of the organic material. However, in some cases, it is re-deposited to become a part of sediments once more. This process should be considered to be a part of global carbon cycle, possibly much more significant than assumed to-date. The research presented here aims to characterize re-worked organic matter occurring in post-glacial sediments of southern part of Poland, in the Oder river valley (the Racib?rz town region, Miocene, Pleistocene and Holocene age). Organic substances extracted from the sediments originated from organic matter that had resided in rocks eroded by glaciers. Sediments were sampled in two boreholes which sediments were correlated. Sediments were extracted and extracts analyzed w...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
In situ treatment has been proposed as a remediation alternative for surface water and groundwater contaminated with uranium and nitrate as a result of former waste disposal practices in the S-3 Ponds. Interceptor trenches containing reactive media have been proposed to treat groundwater, and constructed wetlands and/or algal mats are potential alternatives for treating surface water. This report presents the results from testing of ten different reactive media, and combinations of media, that are candidates for use in the proposed interceptor trenches to remove uranium and nitrate from groundwater. It also presents the results of testing and evaluation of algal mats and wetlands for removing uranium and nitrate from surface water.
1998-01-01
Estimating the erosion and deposition rates in a small watershed by the 137Cs tracing method
International Nuclear Information System (INIS)
Understanding the erosion and deposition rates in a small watershed is important for designing soil and water conservation measures. The objective of this study is to estimate the net soil loss and gain at points with various land use types and landform positions in a small watershed in the Sichuan Hilly Basin of China by the 137Cs tracing technique. Among various land use types, the order of erosion rate was bare rock > sloping cultivated land > forest land. The paddy field and Caotu (a kind of cultivated land located at the foot of hills) were depositional areas. The erosion rate under different landform was in this order: hillside > saddle > hilltop. The footslope and the valley were depositional areas. The 137Cs technique was shown to provide an effective means of documenting the spatial distribution of soil erosion and deposition within the small watershed.
2009-02-01
British Library Electronic Table of Contents (United Kingdom)
In the Lower Rio Grande Valley (LRGV) of Texas, cotton regrows and produces fruit from undestroyed stalks throughout the winter, and in spring weevils from such locations become a serious threat. The success of the boll weevil eradication program, which was reintroduced in the LRGV in 2005, will be dependent on thorough stalk destruction following harvest. However, adverse weather conditions and conservation tillage often impede immediate and complete stalk destruction using typical tool implements, and alternative stalk control methods are needed. This study provides an examination of the efficacy for cotton stalk destruction of different herbicides (thifensulfuron-methyl + tribenuron-methyl, dicamba-diolamine, 2,4-D-dimethylammonium, flumioxazin, 2,4-DB-dimethylammonium and carfentrazone...
2007-01-01
Autoradiographic study of regional distribution of gastric mucosal blood flow
Energy Technology Data Exchange (ETDEWEB)
Iodo(/sup 14/C)antipyrine autoradiography was used to measure gastric mucosal blood flow in anesthetized rats and to study regional distribution. Blood flows of 61 +/- 8 ml.100 g-1.min-1 (means +/- SE) in corpus and 84 +/- 9 ml.100 g-1.min-1 in antral mucosa compared well with previously reported measurements by hydrogen clearance. Blood flow in the crests of corpus mucosal folds was significantly higher than in the valleys between folds, indicating that the greater susceptibility of the former areas to acute injury, documented in several studies, is not associated with a perfusion defect in the resting stomach. Corpus mucosal blood flow was also higher in the side walls of the stomach than in the greater curvature region, and in distal than in proximal locations. No systematic regional variations within antral mucosa were demonstrated.
1988-04-01
British Library Electronic Table of Contents (United Kingdom)
This paper presents a study on Manasbal lake, which is one of the high altitude lakes in the Kashmir Valley, India. Eighteen water samples were analysed for major ions and trace elements to assess the variability of water quality of the lake for various purposes. Geostatistics, the theory of regionalized variables, was then used to enhance the dataset and estimate some missing spatial values. Results indicated that the concentration of major ions in the water samples in winter was higher than in summer. The scatter diagrams suggested the dominance of alkaline earths over the alkali elements. Three types of water were identified in the lake that are referred to as Ca?HCO3, Mg?HCO3 and hybrid types. The lake water was found to be controlled by rock?water interaction with carbonate lithology ...
2011-01-01
Utilizing the right mix of environmental cleanup technologies
International Nuclear Information System (INIS)
The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy nuclear facility located along the Savannah River near Aiken, South Carolina. During operations, which started in 1951, hazardous substances (chemicals and radionuclides) were released to the environment. The releases occurred as a result of inadvertent spills and waste disposal in unlined pits and basins which was common practice before environmental regulations existed. The hazardous substances have migrated to the vadose zone and groundwater in many areas of the SRS, resulting in 515 waste units that are required by environmental regulations, to undergo characterization and, if needed, remediation. In the initial years of the SRS environmental cleanup program (early 1990's), the focus was to use common technologies (such as pump and treat, air stripping, excavation and removal) that actively and tangibly removed contamination. Exclusive ...
2007-09-02
Third RAAN conference: RAAN as Support of Nuclear Power
International Nuclear Information System (INIS)
The proceedings of the third RAAN conference, titled 'RAAN as Support of Nuclear Power', held in Drobeta Turnu-Severin, Romania on 6-7 Nov 2003, are structured on three sections covering the following issues: - Section 1. Energy and Environment (19 papers); - Section 2. Isotopic products (3 papers); - Section 3. Prospects of Nuclear Power development in Romania (17 papers). Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found able to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fruitfully used in construction of the Units 2-5 to be built. Lately Romania's ...
2004-11-06
Reliability analysis of FPSO mooring systems and the interaction with risers
Energy Technology Data Exchange (ETDEWEB)
Turret moored Floating Production Storage and Offloading (FPSO) systems are considered suitable for a wide range of environmental conditions but experience of designing moorings for these units in harsh environments is limited. Furthermore, each floating production system has its own requirements as to the way the riser system is operated because of its dependence on both reservoir and site specific conditions. The current mooring codes do not have a consistent set of requirements; for example, the intact mooring system safety factors range from 1.5 to 2.3. Such vastly differing requirements result in wide variability in the intrinsic safety, reliability and cost. This paper describes a reliability analysis carried out for the first North Atlantic FPSO (Foinaven), to address the acceptance criteria for moorings by returning to the fundamentals. Although the analysis deals with FPSO`s, the approach is applicable to any catenary moored ...
1996-12-31
Performance of SPNDs used in control and safety systems
International Nuclear Information System (INIS)
Large sized reactor such as 540 MWe Pressurised Heavy Water Reactor (PHWR) requires continuous in core monitoring of local flux in order to provide effective control and protection. About 198 self powered neutron detectors (SPNDs) of the straight individually replaceable type are distributed in the reactor core. For purposes of reactor regulation, 42 prompt responding cobalt SPNDs called zone control detectors (ZCDs) are housed in vertical flux units (VFUs) and these are uniformly distributed in 14 power zones. The in core detectors used for spatial control by ZCCs do not accurately represent average zone power as they sense the flux over a small volume. Flux mapping system (FMS) comprising of 102 vanadium SPNDs in 26 VFUs, provide accurate measure of neutron flux, even though they have slow response to change in neutron flux levels. For reactor protection system-1 (RPS-1), 36 cobalt SPNDs are placed in VFUs and become part of core overpower protection system-1 ...
2006-11-13
Neural node network and model, and method of teaching same
Energy Technology Data Exchange (ETDEWEB)
The present invention is a fully connected feed forward network that includes at least one hidden layer 16. The hidden layer 16 includes nodes 20 in which the output of the node is fed back to that node as an input with a unit delay produced by a delay device 24 occurring in the feedback path 22 (local feedback). Each node within each layer also receives a delayed output (crosstalk) produced by a delay unit 36 from all the other nodes within the same layer 16. The node performs a transfer function operation based on the inputs from the previous layer and the delayed outputs. The network can be implemented as analog or digital or within a general purpose processor. Two teaching methods can be used: (1) back propagation of weight calculation that includes the local feedback and the crosstalk or (2) more preferably a feed forward gradient decent which immediately follows the output computations and which also includes the ...
1995-01-01
Modelling and simulation of rate-based mechanistic model for CO{sub 2} capture
Energy Technology Data Exchange (ETDEWEB)
The electric power industry can use the carbon dioxide absorption process to capture carbon from high-volume flue gas. However, the current cost of the process is too high due to the approximation method used in process design. The absorption column is typically designed with parameters that are assumed to be constant over the whole length of the column, resulting in an oversized unit. This approximation method is no longer valid given new environmental and economic concerns. In order to develop an accurate column design for high-efficiency carbon dioxide (CO{sub 2}) capture, it is necessary to understand the phenomena taking place in the system. A mechanistic model is presented for a robust absorber design that takes into account mass-transfer and hydrodynamic behaviour within the CO{sub 2} absorption columns. The capture performance of a packed column under a wide range of design and operating conditions was determined using a model based on ...
2003-07-01
LOOP Inc. (Louisiana Offshore Oil Port Inc. ) to start onshore construction this year
A discussion covers the LOOP project to construct an offshore pipeline system, which will connect with onshore facilities at Fourchon, La., and two onshore pipelines (26 mi 48 in. Clovelly line and 53 mi 48 in. LOCAP line) connecting Fourchon with the existing Capline system at St. James, La.; the three-phase construction schedule, the first phase due to begin in the third quarter of 1978 with, e.g., onshore pipeline and salt dome storage facility construction which will yield an expected initial throughput of 1.4 million bbl/day; the marine terminal complex, consisting of control and pumping platforms, and three 7000 hp pumps to operate the system at 45,000-100,000 bbl/hr; the offshore lines, including lines between single-point mooring units and the pumping platform, the 21 mi 48 in. pipe to Fourchon, and corrosion protection of lines by an asphalt-sand mixture or a semiplasticized coal-tar enamel; the onshore system, including the Fourchon ...
1978-06-01
Energy Technology Data Exchange (ETDEWEB)
This annual report describes the progress during the fourth year of the project on {open_quotes}Integrated Approach Towards the Application of Horizontal Wells to Improve Waterflooding Performance{close_quotes}. The project involves using an integrated approach to characterize the reservoir followed by proposing an appropriate reservoir management strategy to improve the field performance. In the first stage of the project, the type of data we integrated include cross borehole seismic surveys, geological interpretation based on the logs and the cores, and the engineering information. In contrast, during the second stage of the project, we intend to use only conventional data to construct the reservoir description. This report covers the results of the implementation from the first stage of the project. It also discusses the work accomplished so far for the second stage of the project. The production from the Self Unit (location of Stage 1) has sustained an increase ...
1997-01-01
Development of the ELEX process for tritium separation at reprocessing plants
International Nuclear Information System (INIS)
The ELEX process for isotopic enrichment and separation of tritium from aqueous reprocessing effluents is described. After the development of an appropriate hydrophobic catalyst and the study of the separate constituent steps of the ELEX process, an integrated bench-scale installation with a detritiation capacity of 10 mol water per hour was constructed. It comprises essentially a 1.5 kW electrolyser and two 2 cm diameter by 3 m high exchange columns. In this mini-pilot the ELEX process was successfully demonstrated by detritiating more than 1000 dm"3 water containing up to 100 mCi tritium per dm"3, which is the feed concentration expected for application of the process in a reprocessing plant. The process decontamination factor was always larger than 100 and the overall tritium balance could be kept within the experimental errors of the various measurements. Depending on the duration of the runs, the volume reduction factor was between 10 and 15, but this factor will become much ...
1985-03-01
DEVELOPMENT OF TECHNOLOGIES AND ANALYTICAL CAPABILITIES FOR VISION 21 ENERGY PLANTS
Energy Technology Data Exchange (ETDEWEB)
The goal of this DOE Vision-21 project work scope is to develop an integrated suite of software tools that can be used to simulate and visualize advanced plant concepts. Existing process simulation software does not meet the DOE's objective of ''virtual simulation'' which is needed to evaluate complex cycles. The overall intent of the DOE is to improve predictive tools for cycle analysis, and to improve the component models that are used in turn to simulate the cycle. Advanced component models are available; however, a generic coupling capability that will link the advanced component models to the cycle simulation software remains to be developed. In the current project, the coupling of the cycle analysis and cycle component simulation software will be based on an existing suite of programs. The challenge is to develop a general-purpose software and communications link between the cycle analysis software Aspen Plus{reg_sign} (marketed by ...
2002-08-31
Coastal zones : shifting shores, sharing adaptation strategies for coastal environments
Energy Technology Data Exchange (ETDEWEB)
A parallel event to the eleventh Conference of Parties (COP) to the United Nations Framework Convention of Climate Change was held to demonstrate examples of adaptation from around the world in the areas of food security, water resources, coastal zones, and communities/infrastructure. Panels on each theme presented examples from developing countries, countries in economic transition, and developed countries. These 4 themes were chosen because both mitigation and adaptation are essential to meeting the challenge of climate change. The objective of the event was to improve the knowledge of Canada's vulnerabilities to climate change, identify ways to minimize the negative effects of future impacts, and explore opportunities that take advantage of any positive impacts. This third session focused on how coastal communities are adapting to climate change in such places as Quebec, the Caribbean, and small Island States. It also presented the example of how a ...
2006-07-01
Building a Construction Curriculum for Your School District
Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a living lab, with science, math, and economics teachers using the data as teaching tools within classrooms. ...
2010-06-01
Underwater plasma arc cutting in Three Mile Island's reactor
Energy Technology Data Exchange (ETDEWEB)
On March 28, 1979, the Pennsylvania Three Mile Island nuclear power plant Unit 2 (TMI-2) suffered a partial fuel-melt accident. During this accident, over 20,000 lb of molten fuel flowed through holes melted through the baffle plates and through the lower-core support assembly (LCSA). The molten fuel subsequently resolidified in the bottom of the reactor vessel. The lower-core support assembly of the TMI-2 reactor was not structurally damaged during the accident. In order to permit defueling of that region of the core, the LCSA was cut to permit access. A five-axis teleoperator was developed to deliver plasma arc cutting, rotary grinding and abrasive waterjet cutting of end effectors to the LCSA. Complex geometry sectioning was completed in a mock-up facility at chemistry and pressure conditions simulating those of the vessel, prior to actual in-vessel operations. In-vessel activities began in early May 1988 and were completed on April 11, ...
1989-07-01
Energy Technology Data Exchange (ETDEWEB)
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency. The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It begins with a coarse time stage and searching space and refines the time interval between two time stages and the search spacing pass by pass (iteration). With ...
2008-04-15
Program plan for development of underground hydroelectric pumped storage technology
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, drives a hydraulic turbine for power generation. Intermediate ...
1976-03-01
In the Loop : A look at Manitoba's geothermal heat pump industry
International Nuclear Information System (INIS)
This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable operating costs of geothermal heat pumps, high level of comfort, high quality and reliability of geothermal ...
International Nuclear Information System (INIS)
Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar assisted ground-source heat pump (GSHP) unit and the overall system are obtained to be 2.64 and 2.38, respectively. The average exergy efficiency of the system is ...
2005-06-12
Crystallization fouling of calcium sulfate dihydrate on heat-transfer surfaces
Energy Technology Data Exchange (ETDEWEB)
The present paper deals with the fouling process of calcium sulfate dehydrate on heat-transfer surfaces. The crystallization of calcium sulfate showed typical asymptotic fouling curves, the asymptotic value of which was greatly influenced by the surface temperature and fluid velocity. The fouling mechanism was discussed with a generalized fouling model and proved to be surface process controlled, where the activation energy was 6.2 {times} 10{sup 4} J/mol. The availability of mechanical cleaning against the formed scale was quantitatively evaluated by applying the particle abrasion method. The removal test verified that the removing rate per unit particle concentration decreased in an inverse proportion to the overall particle load, to the power of 0.8, and that it was affected by the fluid velocity. The observed final residual fouling resistance decreased asymptotically with an increase in particle concentration. The suitable concentration of the abrasive ...
1996-02-01
Automation in a material processing/storage facility
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site (SRS) is currently developing a new facility, the Actinide Packaging and Storage Facility (APSF), to process and store legacy materials from the United States nuclear stockpile. A variety of materials, with a variety of properties, packaging and handling/storage requirements, will be processed and stored at the facility. Since these materials are hazardous and radioactive, automation will be used to minimize worker exposure. Other benefits derived from automation of the facility include increased throughput capacity and enhanced security. The diversity of materials and packaging geometries to be handled poses challenges to the automation of facility processes. In addition, the nature of the materials to be processed underscores the need for safety, reliability and serviceability. The application of automation in this facility must, therefore, be accomplished in a rational and disciplined manner to satisfy the strict ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed to reduce unnecessary reactor trip by changing steam generator low-low water level reactor trip setpoint(SGLLRTS) for KNU 3 and 4.
2008-10-15
International Nuclear Information System (INIS)
The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed to reduce unnecessary reactor trip by changing steam generator low-low water level reactor trip setpoint(SGLLRTS) for KNU 3 and 4.
2008-10-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
