WorldWideScience
1

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in ...

2008-01-01

2

Remote Sensor Systems for Unmanned Planetary Missions  

Science.gov (United States)

instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...

3

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two ...

1995-10-01

4

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

5

A proposed linac cavity rf drive system for the Los Alamos extreme ultraviolet free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.

1989-01-01

6

Liquid chromatography with ultraviolet and dual parallel mass spectrometric detection for analysis of vitamin D in retail fortified orange juice  

British Library Electronic Table of Contents (United Kingdom)

Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...

2011-01-01

7

Adiabatic interpretation of particle creation in a de Sitter universe  

Energy Technology Data Exchange (ETDEWEB)

The choice of vacuum state for a quantum scalar field propagating in a de Sitter spacetime (massive and arbitrarily coupled to the gravitational field) is discussed. The problem of finite-time initial conditions for the mode functions is analyzed, as well as how these determine the vacuum state of the quantum system. The principle guiding the choice of vacuum state is the following: one wants the vacuum contribution to the energy-momentum tensor to contain all the ultraviolet divergent terms, so that the particle creation terms are finite, and covariantly conserved. There is a suitable set of modes (instantaneous adiabatic basis) in which this splitting of the expectation value of the energy-momentum tensor can be carried out. Numerical results are presented for different finite-time initial conditions (m = 0.6, {zeta} = 1/6). The nature of the particle creation effect is described ...

1998-06-10

8

Specific features and mechanisms of photoluminescence of nanostructured silicon carbide films grown on silicon in vacuum  

British Library Electronic Table of Contents (United Kingdom)

The light-emitting properties of cubic silicon carbide films grown by vacuum vapor phase epitaxy on Si(100) and Si(111) substrates under conditions of decreased growth temperatures (T gr ? 900?700?C) have been discussed. Structural investigations have revealed a nanocrystalline structure and, simultaneously, a homogeneity of the phase composition of the grown 3C-SiC films. Photoluminescence spectra of these structures under excitation of the electronic subsystem by a helium-cadmium laser (?excit = 325 nm) are characterized by a rather intense luminescence band with the maximum shifted toward the ultraviolet (?3 eV) region of the spectral range. It has been found that the integral curve of photoluminescence at low temperatures of measurements is split into a set of Lorentzian components. Th...

2011-01-01

9

Tunable VUV generation by anti-Stokes stimulated Raman conversion of XeCl laser radiation  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on the results of experiments into efficient higher-order anti-Stokes Raman conversion of tunable short-pulse XeCl laser radiation. The maximum output energy of the pumping laser, in which the radiation of a frequency-doubled dye laser is amplified by two XeCl laser amplifiers, is 55 mJ with a pulse duration of 1 ns FWHM. Using hydrogen gas as a Raman medium, a series of anti-Stokes lines up to the 12th order (121.5 nm) is generated in the vacuum ultraviolet (VUV) region. 16 references.

1987-06-01

10

Lasing below 200 nm in the NIJI-IV compact storage-ring-based free electron laser  

International Nuclear Information System (INIS)

Laser gain of the NIJI-IV compact storage-ring-based Free Electron Laser (FEL) system at AIST reached #approx#9% at 200 nm for an average beam current of 16.3 mA. In addition to such a drastic gain enhancement, improvement of the laser-cavity performance has led to successful FEL lasing in the vacuum ultraviolet below 200 nm even in a compact system. Temporal and spectral characteristics of the NIJI-IV FEL were examined around 200 nm. FEL performance will be briefly discussed from the application point of view.

2004-08-01

11

Surface analysis by Fourier-transform infrared (FTIR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.

1981-08-12

12

Potassium deposition on a thiophene-terminated alkanethiol monolayer  

International Nuclear Information System (INIS)

Potassium deposition in ultrahigh vacuum on 12-(3-thienyl)dodecanethiol monolayers assembled on gold surfaces has been investigated using X-ray and ultraviolet photoelectron spectroscopies (XPS and UPS). Angle-resolved XPS indicates that initially deposited potassium penetrates the self-assembled monolayer (SAM) and diffuses to the SAM/Au interface. Even after large metal doses, the presence of thiophene ring valence electronic states in the UPS spectra confirms that most of the thiophene rings (at the SAM/vacuum interface) are not covered by potassium. The binding energy shifts of the thiophene ring valence states and the C1s and thiophene S2p peaks, referenced to the Fermi level, are due to the work function changes of the gold substrate. This indicates that these electronic states are pinned to the vacuum level, in contrast to the thiolate S2p orbital, which is pinned to the Fermi level. For large ...

2009-05-01

13

FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons  

International Nuclear Information System (INIS)

Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those at the temperature of interest because of ...

1990-04-01

14

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

15

Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds  

Science.gov (United States)

The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...

1990-01-01

16

UPS fine structures of highest occupied band in vanadyl-phthalocyanine ultrathin film  

Energy Technology Data Exchange (ETDEWEB)

Ultraviolet photoelectron spectra were measured for vanadyl phthalocyanine (VOPc) ultrathin films prepared on graphite to study effects of the molecular orientation and the electric dipole layer on the organic electronic states. VOPc has a permanent electric dipole perpendicular to the molecular plane, hence a well-defined electric dipole layer could be intentionally prepared by using the oriented monolayer. The observed binding-energy difference of the highest occupied molecular orbital (HOMO) bands between the oriented monolayer and the double layer was found to agree with the vacuum level shift, leading to a conclusion that the molecular energy level with respect to the substrate Fermi level is changed when the molecule is in the electric dipole layer.

2005-06-15

17

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that ...

18

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer  

CERN Document Server

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer

1998-01-01

19

Modifications to the rotating crystal spectrometer  

International Nuclear Information System (INIS)

... bf3 counters data multi-channel analyzers multivibrators neutron spectrometers

20

KLOE-2 experiment at DA$\\Phi$NE upgraded in luminosity  

CERN Document Server

Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.

2011-01-01

21

Ozone Layer Observations  

Science.gov (United States)

The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical ...

2002-01-01

22

Modeling paraxial wave propagation in free-electron laser oscillators  

International Nuclear Information System (INIS)

Modeling free-electron laser (FEL) oscillators requires calculation of both the light-beam interaction within the undulator and the light propagation outside the undulator. We have developed a paraxial optical propagation code that can be combined with various existing models of gain media, for example, Genesis 1.3 for FELs, to model oscillators with full paraxial wave propagation within the resonator. A flexible scripting interface is used both to describe the optical resonator and to control the codes for propagation and amplification. To illustrate its capabilities, we numerically investigate two significantly different FEL oscillators: the free-electron laser for infrared experiments (FELIX) system and the vacuum-ultraviolet (VUV)-FEL oscillator of the proposed high-gain fourth generation light source. For the FELIX system, we find that diffraction losses are a considerable part of the single-pass cavity loss (at a wavelength of 40 #mu#m). We also demonstrate ...

2006-11-01

23

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV ...

1996-05-01

24

Luminescence properties of europium and terbium activated yttrium niobium/tantalate phosphors under VUV-UV excitation  

International Nuclear Information System (INIS)

Various compositions of Y(Ta,Nb)O4:Eu3+,Tb3+ with different Nb and activator concentrations have been investigated under UV and VUV excitation. Some compounds with very strong emission under VUV excitation were found. Such phosphors could be proposed as very good emissive materials for Displays and Lightings. The growing interest in luminescence spectroscopy of rare earth ions in the vacuum ultraviolet (VUV) and the visible (VIS) spectral range is due to industrial demands for new applications. YTaO4 and YNbO4 phosphors are a perspective class of efficient materials that are generally used in X-ray intensifying screens. These phosphors exhibit satisfying luminescence whenever excited by UV light, cathode radiation or X ray. However, to our knowledge, no work has been published on the VUV-excited luminescence for Eu3+ and Tb3+ double activated yttrium niobate and yttrium tantalate based phosphors. In this paper, the VUV-UV PL and PLE spectra of ...

25

Free-Electron Lasers: Present Status and Future Prospects  

Energy Technology Data Exchange (ETDEWEB)

Free-electron lasers as scientific instruments are reviewed. The present status and future prospects are delineated with attention drawn to the size, complexity, availability, and performance capability of this new tool. The Free-Electron Laser (FEL) was proposed by John Madey in 1970 (1), although earlier work, relevant to the concept, had been performed by Motz (2) and by Phillips (3). Experimental demonstration was achieved by Madey, et. al. in 1975 and 1976 (4). Since that time, FELs of diverse configurations have been operated at several laboratories around the world. At present, FEL development is focused in two directions: in constructing reliable FELs for scientific research and in extending FEL capability to vacuum ultra-violet (VUV) and even shorter wavelengths. In this article we shall only very briefly review the principles of an FEL, putting emphasis on those aspects that limit performance, after which we shall discuss the ...

1990-05-01

26

Benzene molecule is destroyed by ultraviolet and soft X-rays in circumstellar environment  

International Nuclear Information System (INIS)

Benzene molecules , present in the proto-planetary nebula CRL 618, are ionized and dissociated by ultraviolet (UV) and X-ray photons originated from the hot central star and by its fast wind. Ionic species and free radicals produced by these processes can lead to the formation of new organic molecules. The aim of this work is to study the photoionization and photodissociation processes of the benzene molecule, using synchrotron radiation and time-of-flight mass spectrometry. Mass spectra were recorded at different energies corresponding to the vacuum UV (21.21 eV) and soft X-ray (282-310 eV) spectral regions. The production of ions from the benzene dissociative photoionization is here quantified, indicating that C_6H_6 is more efficiently fragmented by soft X-ray than UV radiation, where 50% of the ionized benzene molecules survive to UV dissociation while only about 4% resist to C-rays. Partial ion yields of H and small hydrocarbons, such as ...

28

K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma  

Energy Technology Data Exchange (ETDEWEB)

K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.

1985-05-01

30

Evolution of ultraviolet dwarfs  

Science.gov (United States)

UV dwarf star evolution, using central and gap star models emphasizing photoneutrino emission

1969-01-01

31

Thermal stability of nanocomposite CrC/a-C:H thin films  

International Nuclear Information System (INIS)

The thermal stability of low-friction Me-C/a-C:H coatings is important for their potential applications in the tool and automotive industry. Recently we showed that CrC _x/a-C:H coatings prepared by unbalanced magnetron sputtering of a Cr target in Ar + CH_4 glow discharges exhibit a nanocomposite structure where metastable fcc CrC nanocrystals are encapsulated by an a-C:H phase. Here, we present the structural evolution of these nanocomposite CrC/a-C:H coatings during annealing. High-temperature X-ray diffraction in vacuum and differential scanning calorimetry (DSC) combined with thermo-gravimetric analysis in Ar atmosphere indicate decomposition of the formed metastable fcc CrC phase and subsequent formation of Cr_3C_2 and Cr_7C_3 and structural transformation of the a-C:H matrix phase towards higher sp"2 bonding contents at temperatures above 450 deg. C. Combined DSC and mass spectrometer analysis as well as elemental profiling after ...

2007-05-07

33

Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997  

Energy Technology Data Exchange (ETDEWEB)

This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the automated ...

1998-07-01

34

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

35

Suppression of pitting corrosion with passive film modification on type 304 stainless steel by ultra-violet light irradiation; Shigaikoshosha ni yoru Type 304 stainless ko no fudotai himaku kaishitsu to koshoku yokusei  

Energy Technology Data Exchange (ETDEWEB)

In this study, the effects of 325nm wavelength ultraviolet light irradiation on pitting corrosion behavior of type 340 stainless steel in a neutral chloride solution are studied. Further, the change of passive film with the light irradiation is analyzed using x-ray photoelectron spectroscopy. The mains results obtained therefrom are stated below. Pitting potential can be shifted in noble direction by the ultraviolet light irradiation. The effect of ultraviolet light irradiation is ore prominent in the pitting corrosion process than that in the passive film formation. The result of the analysis in terms of the birth and death stochastic probability process shows that pitting corrosion rate is decreased remarkably by the ultraviolet light irradiation at the formation of passive film, while the repassivation is slightly expedited by the ultraviolet light irradiation. On the other hand, ...

1998-06-20

36

Photosynthetic Response of Seagrasses to Ultraviolet-A Radiation and the Influence of Visible Light Intensity 1  

UK PubMed Central (United Kingdom)

Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available

1982-02-01

39

The sup(187m)Ir isomer state and its decay scheme  

International Nuclear Information System (INIS)

... beta spectrometers comparative evaluations data decay electrons

40

The conversion spectrum of Sr"8"8  

International Nuclear Information System (INIS)

... beta spectrometers decay energy-level transitions k conversion l conversion

45

Vacuum structures in Hamiltonian light-front dynamics  

Energy Technology Data Exchange (ETDEWEB)

Hamiltonian light-front dynamics of quantum fields may provide a useful approach to systematic nonperturbative approximations to quantum field theories. The authors investigate inequivalent Hilbert-space representations of the light-front field algebra in which the stability group of the light front is implemented by unitary transformations. The Hilbert space representation of states is generated by the operator algebra from the vacuum state. There is a large class of vacuum states besides the Fock vacuum which meets all the invariance requirements. The light-front Hamiltonian must annihilate the vacuum and have a positive spectrum. Relations are exhibited of the Hamiltonian to the nontrivial vacuum structure. 30 refs.

1994-03-01

46

Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A  

Energy Technology Data Exchange (ETDEWEB)

Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

1986-10-01

47

Vacuum instability and tachyons: comments on a paper by Zeldovich  

International Nuclear Information System (INIS)

It is shown that vacuum instabilities possibly arising because of tachyons do not contradict any experimental evidence, and therefore that no objection against tachyon existence can be found even on this ground. (Auth.).

48

Cold vacuum drying facility design requirements; FINAL  

International Nuclear Information System (INIS)

This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.

49

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

50

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

51

USSR Report, Electronics and Electrical Engineering.  

Science.gov (United States)

... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...

1985-04-30

52

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

53

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

54

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

55

f 07821-6004-R0-00 RESEARCH PROGRAM ON HOLOGRAPHIC - NASA ...  

Science.gov (United States)

in a KDP crystal fed with red light from a Q-s_tched ruby laser. One reason for interest in holograms made with ultraviolet ...

56

Test and Evaluation of Liquid Polymers for Use in Army ...  

Science.gov (United States)

... The addition of 0.5 pphr of fine thermal carbon black to the polymers gave good resistance to 500 hours of ultraviolet (UV) xposure in a Weather ...

1972-10-01

57

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

58

FOCUS: time-of-flight spectrometer for cold neutrons at SINQ  

Energy Technology Data Exchange (ETDEWEB)

The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.

1996-11-01

59

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

62

Vacuum container for use in a thermonuclear device  

International Nuclear Information System (INIS)

Purpose: To enable the use of a vacuum container under a relatively high temperature or a high level radioactive dose. Constitution: Vacuum sealing materials for use in a vacuum container are made of resins such as polyimide and polyamide. The sealing materials are joined to the both surfaces of a plate-like insulator by means of adhesives or sealants, or the sealing materials are joined between two plate-like insulators by means of adhesives or sealants. They are situated within grooves of both of flanges, which are clamped tightly by insulation bolt and nut. Since the vacuum sealing materials are joined to the insulator by means of the adhesives or sealants, the reliability of the vacuum sealing can be improved without impairing the electrical insulation. The resin of the vacuum sealing material can be used for the radiation dose up to 10"8 rad, temperature up ...

1982-04-30

63

LCLS XTOD Tunnel Vacuum System (XVTS)  

Energy Technology Data Exchange (ETDEWEB)

The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.

2005-11-04

64

Simultaneous ultraviolet spectrophotometric determination of nitrate and nitrite in water  

Energy Technology Data Exchange (ETDEWEB)

A rapid and accurate method for the direct simultaneous determination of nitrate and nitrite is proposed. The method is applied to the determination of nitrate and nitrite in rainwater and wastewater without preliminary separation. The determinations are performed by a CPA matrix method with ultraviolet spectrophotometric detection. The results obtained are in agreement with those obtained by conventional methods for the determination of nitrate and nitrite.

1991-02-01

65

Electronic structure of the Ru(0001) surface  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the electronic structure of ruthenium. Synchrotron radiation in the range from 15 to 45 eV and angle-resolved ultraviolet photoemission are used to map the energies of the electronic states. The Fermi surface of Ru is determined using angle-resolved ultraviolet photoemission spectroscopy. The experimental results are compared with calculated photoemission spectra obtained within the framework of the one-step model of photoemission. (author)

2000-03-13

66

Effect of UV radiation on the killer phenotype in the wine yeast-saccharomycetes and spontaneous variation of this character  

International Nuclear Information System (INIS)

Spontaneous and ultraviolet-induced changeabilities of wine yeasts from the killer state to sensitive one have been studied. Observed often spontaneous changes of killer and neutral phenotypes under laboratory store conditions as well as high mutation frequency of genetic elements responsible for the killer indication on ultraviolet irradiation testify that often encounterability in nature and in the production of sensitive yeasts is attributed to high frequency of mutation changes of the killer and neutral phenotypes to the sensitive state.

67

Selective absorption of ultraviolet laser energy by human atherosclerotic plaque treated with tetracycline  

Energy Technology Data Exchange (ETDEWEB)

Tetracycline is an antibiotic that absorbs ultraviolet light at 355 nm and preferentially binds to atherosclerotic plaque both in vitro and in vivo. Tetracycline-treated human cadaveric aorta was compared with untreated aorta using several techniques: absorptive spectrophotometry; and tissue uptake of radiolabeled tetracycline, which showed 4-fold greater uptake by atheroma than by normal vessel. In addition, intravenous tetracycline administered to patients undergoing vascular surgery demonstrated characteristic fluorescence in surgically excised diseased arteries. Because of tetracycline's unique properties, the authors exposed tetracycline-treated and untreated aorta to ultraviolet laser radiation at a wavelength of 355 nm. They found enhanced ablation of tetracycline-treated atheroma compared with untreated atheroma. The plaque ablation caused by ultraviolet laser radiation was twice as extensive in ...

1985-05-01

68

hysics Facility - NASA  

Science.gov (United States)

vehicles including the H2-A rocket and the space shuttle. .... The vacuum can's main function is to provide a high vacuum so that the science experiment and its sensors ... EMI-shielded power conversion from the incoming ISS power supply. 4. ...

69

Yttrium Oxides in Vacuum-Plasma-Sprayed CoNiCrAlY ...  

Science.gov (United States)

... Accession Number : ADD141533. Title : Yttrium Oxides in Vacuum-Plasma- Sprayed CoNiCrAlY Coatings,. Descriptive Note : Journal Article,. ...

1989-06-01

70

Memory effect in air in the presence of vacuum breakdown mechanism  

Science.gov (United States)

Investigation of memory effects in air at 0.7 mbar pressure in the presence of vacuum electrical breakdown mechanism has been performed in this paper. The memory effect has been followed using the time delay method.

2008-07-01

71

PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies  

Energy Technology Data Exchange (ETDEWEB)

We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).

1990-09-15

72

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

73

Vacuum-plasma treatment induced modification of the surface of high-speed steel cutting tools  

International Nuclear Information System (INIS)

The possibility of surface modification of high-speed steel cutting tool by means of vacuum-plasma treatment including ion nitriding in gas plasma followed by the deposition of wear resistant (Ti, Al)N coatings in metal-gas plasma of a vacuum arc discharge is studied. The regularities of nitrided layer formation and the structure of these layers under various operation conditions of cutting tool are investigated. Optimum conditions of vacuum-plasma treatment providing the best wear resistance of cutting are determined

74

Vacuum Packaging for Microelectromechanical Systems ...  

Science.gov (United States)

... more than expected in developing a unique bond strength measurement protocol that is important for a wide range of bond strength measurements. ...

2002-10-01

75

Tritium Oxide Content Control  

International Science & Technology Center (ISTC)

Development of Method and Technical Project of the Plant for Thermo-Vacuum Desorption of Tritium Oxide (HTO) from the Environmental Samples

76

HIGH VOLTAGE BREAKDOWN STUDY. ADDENDUM: SOME ...  

Science.gov (United States)

... The nature of the vacuum breakdown mechanism presents just such a problem and the relative significance or total absence of several processes ...

1968-10-01

77

Evolution of a vacuum shell in the Friedmann-Schwarzschild world  

International Nuclear Information System (INIS)

The method of an effective potential is used to investigate the possible types of evolution of vacuum shells in the Friedmann-Schwarzschild world. Such shells are assumed to emerge during phase transitions in the early Universe. The possible global geometries are constructed for the Friedmann-Schwarzschild worlds. Approximate solutions to the equation of motion of a vacuum shell have been found. The conditions under which the end result of the evolution of the vacuum shells under consideration is the formation of black holes and wormholes with baby universes inside have been found. The interior of this world can be a closed, flat, or open Friedmann universe.

2008-08-01

79

Contact lens disinfection by ultraviolet light  

Energy Technology Data Exchange (ETDEWEB)

A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction.

1989-12-15

80

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

81

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

82

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

83

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

84

Vacuum system pump down analysis  

Energy Technology Data Exchange (ETDEWEB)

My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.

1990-08-01

85

Embedded systems for vacuum control at PEFP  

International Nuclear Information System (INIS)

Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.

2005-05-26

86

UV renormalons in QCD and their phenomenological implications  

International Nuclear Information System (INIS)

I report on some recent work done in collaboration with E. de Rafael on the connection between ultraviolet renormalons in QCD and Nambu-Jona-Lasinio-like Lagrangians as its effective description at low energies. (orig.)

1998-05-01

87

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... The Payload combines some of the most sensitive particle sensors .... provide state-of-the-art measurements of incoming x-ray, ultraviolet, .... It will be launched into a low-Earth orbit on a Delta 7320 rocket in September 2004. ...

88

Sunbed use during adolescence and early adulthood is associated with increased risk of early-onset melanoma  

UK PubMed Central (United Kingdom)

Sunbed use is associated with increased risk of melanoma. Younger people might be more susceptible to the carcinogenic effects of ultraviolet radiation. We investigated the association between...Full Text Available

2011-05-01

89

Simultaneous Reactivation of Ultraviolet Damage in Xanthium Leaves 1  

UK PubMed Central (United Kingdom)

Experiments on Xanthium leaf discs were carried out to determine whether concomitant photoreactivation could be detected and if so, to compare its effects with photoreactivation due...Full Text Available

1969-12-01

90

Simulation study of chiral two dimensional ultraviolet (2DUV) spectroscopy of the protein backbone  

UK PubMed Central (United Kingdom)

Amide n –π* and π-π* excitations around 200 nm are prominent spectroscopic...Full Text Available

2010-06-09

91

Photoelectron spectroscopy of carbonyls: benzoic acid and its derivatives  

Energy Technology Data Exchange (ETDEWEB)

The ultraviolet photoelectron spectra of benzoic acid and 20 of its derivatives are presented. The low-energy regions of these spectra are deconvoluted and assigned using chemical substitution effects. 5 figures, 3 tables.

1981-01-01

92

Photoconductive ultraviolet detectors based on ZnO films  

Energy Technology Data Exchange (ETDEWEB)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...

2006-12-15

93

Photoconductive ultraviolet detectors based on ZnO films  

International Nuclear Information System (INIS)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...

2006-12-15

94

Lack of adequate sun protection for children with oculocutaneous albinism in South Africa  

UK PubMed Central (United Kingdom)

BackgroundChildhood is a high risk time for ultraviolet induced skin damage as this age group has more time and opportunity to be outdoors in the sun. Children in Africa with the...Full Text Available

95

In vitro and in vivo estrogenicity of UV screens.  

UK PubMed Central (United Kingdom)

Ultraviolet (UV) screens are increasingly used as a result of growing concern about UV radiation and skin cancer; they are also added to cosmetics and other products for light stability. Recent data...Full Text Available

2001-03-01

96

Chemoprevention of Nonmelanoma Skin Cancer With Celecoxib: A Randomized, Double-Blind, Placebo-Controlled Trial  

UK PubMed Central (United Kingdom)

BackgroundPreclinical studies indicate that the enzyme cyclooxygenase 2 plays an important role in ultraviolet-induced skin cancers. We evaluated the efficacy and safety of celecoxib,...Full Text Available

2010-12-15

97

A rational vision of stratospheric ozone  

Energy Technology Data Exchange (ETDEWEB)

This work deals with a rational vision of stratospheric ozone including the threats on ozone layer, the verifications and the fears. After a recalling on the ozone layer history, the authors treats the question of the ultraviolets particularly the beneficial effects. Then an explanation of the ozone layer decrease is given. (O.L.). 29 refs., 6 figs.

1995-03-01

98

Study of the outgassing behavior of SnO_2:F films on glass in vacuum under external energy excitation  

International Nuclear Information System (INIS)

Vacuum glazing consists of an evacuated space between two sheets of glass. Vacuum glazing has a large effect on energy savings in houses and buildings. Vacuum glazing can achieve higher insulating performance than conventional insulated glazing. Nippon Sheet Glass has successfully developed conventional vacuum glazing. In this study we investigated an advanced form of vacuum glazing. Its thermal insulation ability is equivalent to 100 mm thick glass wool thermal insulation. This vacuum glazing contained a SnO_2:F low emissivity surface. The influence of the residual gas in a vacuum space on heat flow is important to performance. For long-term thermal stability, it is very important to maintain vacuum stability. To understand this better, we studied the behavior of outgassing from the inside glass surfaces exposed to an ...

2005-06-15

99

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, ...

1999-05-01

100

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

101

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

102

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

103

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

104

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

105

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

106

MEMS-based Speckle Spectrometer  

CERN Document Server

We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing ...

2006-01-01

107

H2/Ar and vacuum annealing effect of ZnO thin films deposited by RF magnetron sputtering system  

British Library Electronic Table of Contents (United Kingdom)

The properties of ZnO films were investigated as functions of annealing temperatures in H2/Ar and vacuum. The resistivities and mobilities of ZnO films decreased with increase of annealing temperatures in vacuum and H2/Ar ambients. However, the carrier densities of ZnO films increased with increase of annealing temperatures in vacuum and H2/Ar ambients. The resistivities of ZnO2 films annealed at 300degreeC were 2186cm and 798cm in H2/Ar and vacuum ambients, respectively. The resistivities of ZnO films annealed in vacuum and H2/Ar ambients at 600degreeC were similar with 0.040cm and 0.035cm, respectively. The hydrogen donor was more dominant than the oxygen vacancy or Zn interstitial donor in ZnO films annealed in ambient H2/Ar at low temperatures. The average optical transmission was >82%...

2010-01-01

108

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best ...

2006-12-21

109

Solid state alkali metal-halogen cell  

Energy Technology Data Exchange (ETDEWEB)

A solid electrolyte cell comprises an alkali metal anode, e.g. lithium, a halogen-containing organic polymer cathode and a solid elecrolyte between the anode and the cathode. The cathode comprises iodine-containing vacuum-cyclised polyacrylonitrile, and the solid electrolyte is preferably lithium iodide and halogen-free vacuum-cyclised polyacrylonitrile. This patent also discloses the use of isotactic polyacrylonitrile, a method of making a cathode comprising iodine-containing vacuum-cyclised polyacrylonitrile, and novel methods of making the solid elecrolyte cells described.

1988-04-26

110

Mercury vacuum cleaner operational test and evaluation  

Energy Technology Data Exchange (ETDEWEB)

The Dental Investigation Service, USAFSAM, Brooks AFB, has outlined the need for a vacuum unit to be used in the Air Force dental clinics. The unit must be capable of effectively picking up mercury and at the same time not redistribute mercury vapors throughout the dental clinic during normal operations or mercury-spill situations. The Dental Investigation Service selected the MRS-3, Minuteman Mercury Recovery System, product of American Cleaning Equipment Corporation as the mercury vacuum to be used for T E. The USAF OEHL/ECH was requested by the Dental Investigation Service to perform the T E on the MRS-3 for possible health hazards due to exposures of mercury vapors.

1981-03-01

111

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

112

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

113

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...

2010-11-11

114

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

115

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

116

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

117

Diode laser overtone spectroscopy of CO_2 at 780nm  

International Nuclear Information System (INIS)

Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbance detected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.

2005-12-01

118

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement ...

1985-07-03

119

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

120

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-09-01

121

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

122

Vacuum distillation refining and recycling of magnesium alloys  

Energy Technology Data Exchange (ETDEWEB)

Purification parameters of the vacuum distillation process for AM50A and AZ31B magnesium alloy were studied. The vacuum distillation tests were kept at 580 C to 620 C up to 10 h under a vacuum pressure of about 1 Pa. The purification ratio for AM50A magnesium alloy increases with increasing the purification time. The chemical compositions of materials deposited purifying at 580 C for AM50A magnesium alloy almost satisfy the values for pure magnesium specified by JIS standard specification. The chemical compositions of deposited materials at 600 C for AZ31B magnesium alloy satisfy the values specified by the standard specification except for Zn. (orig.)

2003-07-01

123

Three generation vacuum oscillations and the solar neutrino problem  

CERN Document Server

We investigate the solar neutrino problem in the scenario of three generation neutrino oscillation hypothesis, taking into account other phenomenological constraints to the neutrino mixing and mass parameters.

1994-01-01

124

The surface topography of the choroid plexus. Environmental, low and high vacuum scanning electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...

2011-01-01

125

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

126

Dielectric characteristics of vacuum circuit breakers with CuCr and CuBi contacts before and after short-circuit breaking operations  

British Library Electronic Table of Contents (United Kingdom)

This paper presents the results of the degree of irreversible changes of dielectric properties of vacuum circuit breakers with CuCr and CuBi contacts before and after short-circuit breaking operations. Tests of dielectric properties were performed on four different types of switching vacuum chamber with RMF electrodes in the form of a spiral disk with slots. The paper describes the configuration of measuring system for determining the dielectric properties of circuit breakers with DC, AC and pulse voltage. It also describes the measuring procedure. The results were analyzed and the experimentally obtained random variable breakdown voltage is found to belong to Weibull distribution in all cases. Based on these results it was found that for the vacuum circuit breakers with CuCr contacts and ...

2011-01-01

127

Design and installation of a low particulate, ultrahigh vacuum system for a high power free-electron laser  

International Nuclear Information System (INIS)

A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.

1999-03-01

128

A variational approach to the Gross-Neveu model  

Energy Technology Data Exchange (ETDEWEB)

The authors solve the instability of perturbative vacuum of Gross-Neveu model. They use a variational method. The analysis is nonperturbative as it uses only equal time commmutator/anticommutator algebra.

1988-01-01

129

Ultraviolet radiation for the sterilization of contact lenses  

Energy Technology Data Exchange (ETDEWEB)

Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally ...

1990-10-01

130

Ultraviolet radiation for the sterilization of contact lenses  

International Nuclear Information System (INIS)

Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally ...

131

Extreme Ultraviolet Emission from Abell 4059  

CERN Document Server

We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 months we disprove claims of substantial time ...

2000-01-01

132

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

133

Revision I July 29, 2009 - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...

134

Project Technical ... - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...

135

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...

1991-06-18

136

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...

1989-04-04

137

AMS Project Plan - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...

138

A new analysis for membrane noise. The integral spectrum.  

UK PubMed Central (United Kingdom)

A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available

1976-07-01

139

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

140

Results from a Bragg Curve Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-01-01

141

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-10-22

142

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

143

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

144

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

145

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

146

In-place testing of HEPA filter systems by the single-particle, particle-size spectrometer method  

Energy Technology Data Exchange (ETDEWEB)

This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.

1981-12-01

147

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

148

Application of the digital waveform analysis to Bragg curve spectrometer  

International Nuclear Information System (INIS)

Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)

2004-11-01

149

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

150

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

151

Ultraviolet-B Phototoxicity and Hypothetical Photomelanomagenesis: Intraocular and Crystalline Lens Photoprotection  

British Library Electronic Table of Contents (United Kingdom)

Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...

2010-01-01

152

Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films  

British Library Electronic Table of Contents (United Kingdom)

Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.

2008-01-01

153

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

154

The VOISE Algorithm: a Versatile Tool for Automatic Segmentation of Astronomical Images  

CERN Document Server

The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal and longitudinal ...

2009-01-01

155

Synthesis of ultraviolet curable encapsulating adhesives and their package applications for organic optoelectronic devices  

British Library Electronic Table of Contents (United Kingdom)

With conventional heating process, ultraviolet (UV) illumination, and microwave irradiation, we have successfully synthesized UV curable encapsulating adhesives with excellent gas barrier capabilities, good adhesive strength, moderate hardness, and high refractive indices. The experimental results manifest that the physical properties of lab-made encapsulating adhesives are highly dependent on their chemical structures and synthetic procedure. We also discover that the encapsulating adhesive prepared by microwave irradiation (i.e. encapsulating adhesive VI-MW) exhibits better adhesive strength and higher gas resistance than those prepared by conventional heating process and UV illumination. Furthermore, encapsulating adhesive VI-MW has also been applied for the package of organic light emi...

2011-01-01

156

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

157

Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation  

International Nuclear Information System (INIS)

Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for different times.

158

Composition and method for encapsulating photovoltaic devices  

Energy Technology Data Exchange (ETDEWEB)

A composition and method for encapsulating a photovoltaic device which minimizes discoloration of the encapsulant. The composition includes an ethylene-vinyl acetate encapsulant, a curing agent, an optional ultraviolet light stabilizer, and/or an optional antioxidant. The curing agent is preferably 1,1-di-(t-butylperoxy)-3,3,5-trimethylcyclohexane; the ultraviolet light stabilizer is bis-(N-octyloxy-tetramethyl) piperidinyl sebacate and the antioxidant is selected from the group consisting of tris (2,4-di-tert-butylphenyl) phosphite, tetrakis methylene (3,5-di-tert-butyl-4-hydroxyhydrocinnamate) methane, octadecyl 3,5-di-tert-butyl-4-hydroxyhydrocinnamate, and 2,2'-ethylidene bis(4,6-di-t-butylphenyl) fluorophosponite. The composition is applied to a solar cell then cured. The cured product contains a minimal concentration of curing-generated chromophores and resists UV-induced degradation.

2000-01-01

159

Characteristics of lanthanides in pyrochemical systems observed by electrochemical and spectrophotometric measurements  

Energy Technology Data Exchange (ETDEWEB)

As research for the chemical properties of lanthanide molecules in the dry system, electrochemical and ultraviolet-visible optical measurements on the chloride molten salt system have been conducted at Research Reactor Institute, Kyoto University. The reduction behavior of Ln(III)-Ln(0) and Ln(II) are measured on La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, and Yb by the cyclic voltammetry. The molar absorption coefficients of the f-f transition are measured by the measurement of ultraviolet-visible absorption spectra on Pr, Nd, Ho and Gd. From the comparison of the optical data between wet and dry systems, the characteristics of photon absorption are discussed in the molten salt. (H. Katsuta)

2001-12-01

160

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated ...

1999-11-01

161

Vacuum arc ignition by penning discharge in a strong magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc ...

1995-12-31

162

NEW DEVELOPMENT IN THE VACUUM MELTING AND CASTING OF URANIUM IN TONNAGE QUANTITIES. Transactions of the Vacuum Metallurgy Conference, 1960  

Science.gov (United States)

> Develoopments which have imporved fuel core quality and reduced production costs are described. These developments in the melting and casting of uranium ingots arei modification of the crucible and knockout-slide assembly, substitution of uncoated crucibles for coated crucibles, and substitution of a one-piece gun barrel mold for a vertically split mold. (N.W.R.)

1961-01-01

163

Cold Vacuum Drying (CVD) Facility Technical Safety Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Technical Safety Requirements (TSRs) for the Cold Vacuum Drying Facility define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation. Controls required for public safety, significant defense-in-depth, significant worker safety, and for maintaining radiological and toxicological consequences below risk evaluation guidelines are included.

1999-12-16

164

Calcium fluoride window mounting  

International Nuclear Information System (INIS)

A technique has been developed for joining a large calcium fluoride crystal to a stainless-steel flange by means of a silver transition ring. The process involves both vacuum brazing using a copper-silver alloy and air brazing using silver chloride. This paper describes the procedure used in fabricating a high-vacuum leak-tight calcium fluoride window assembly.

165

Algebraic description of perturbation theory in quantum electrodynamics  

Energy Technology Data Exchange (ETDEWEB)

An algebraic formulation of the electromagnetic field in which various quantization procedures can be described was chosen to discuss perturbation calculations. It is shown that the Feynman rules and the second order calculation of the self-energy of the electron can be developed on the basis of the Fermi method of quantization. The algebraic approach clarifies the problems in defining the vacuum and other states which are associated with calculations in terms of field algebra operators. It is demonstrated that the vacuum state defined on the field algebra by Schwinger leads to incorrect results in the self-energy calculation.

1982-01-01

166

Jacobi stability of the vacuum in the static spherically symmetric brane world models  

International Nuclear Information System (INIS)

We analyze the stability of the structure equations of the vacuum in the brane world models, by using both the linear (Lyapunov) stability analysis, and the Jacobi stability analysis, the Kosambi-Cartan-Chern theory. In the brane world models the four-dimensional effective Einstein equations acquire extra terms, called dark radiation and dark pressure, respectively, which arise from the embedding of the three-brane in the bulk. Generally, the spherically symmetric vacuum solutions of the brane gravitational field equations have properties quite distinct as compared to the standard black hole solutions of general relativity. We close the structure equations by assuming a simple linear equation of state for the dark pressure. In this case the vacuum is Jacobi stable only for a small range of values of the proportionality constant relating the dark pressure and the dark radiation. The unstable trajectories on the brane behave ...

2008-05-15

167

Design of the ZTH vacuum liner  

Energy Technology Data Exchange (ETDEWEB)

The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between ...

1987-01-01

168

Temperature dependence of the performance of ultraviolet detectors  

Energy Technology Data Exchange (ETDEWEB)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...

2003-08-21

169

Temperature dependence of the performance of ultraviolet detectors  

International Nuclear Information System (INIS)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...

2003-08-21

170

Spectrophotometric technique quantitatively determines NaMBT inhibitor in ethylene glycol-water solutions  

Science.gov (United States)

Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.

1967-01-01

171

S179D prolactin diminishes the effects of UV light on epidermal gamma delta T cells  

UK PubMed Central (United Kingdom)

Epidermal gamma delta T cells (γδ T) and Langerhans cells (LC) are immune cells altered by exposure to ultraviolet radiation (UVB), a powerful stressor resulting in immune suppression....Full Text Available

2008-01-02

172

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

173

Ozone layer  

Energy Technology Data Exchange (ETDEWEB)

Governments around the world will soon make decisions on policies that could determine the fate of the ozone layer-the Earth's shield from harmful ultraviolet radiation. The Vienna Convention for the Protection of the Ozone Layer, signed on March 22, 1985, created a framework for scientific cooperation and information exchange that will form the basis for a protocol for controlling substances thought to threaten the ozone layer. As of mid-1987, 29 countries had signed the Convention, including the major producers and users of chlorofluorocarbons (CFCs), the most important of suspect chemicals.

1987-12-01

174

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

175

Conductive, spin-cast carbon films from polyacrylonitrile  

Energy Technology Data Exchange (ETDEWEB)

Polyacrylonitrile films have been spin cast and pyrolyzed to produce thin (500--1500 A) carbon films. These films have higher electrical conductivities than films produced by other methods at similar temperatures. The conductivity can be varied by at least four orders of magnitude by changing the pyrolysis temperature. Ultraviolet, infrared, and Raman spectroscopies were used to investigate the chemical structure of the films during different stages of processing.

1987-05-18

176

Clinical translation of ultraviolet autofluorescence microscopy towards endomicroscopy for early detection of cancer  

Science.gov (United States)

The non-invasiveness of autofluorescence technology may reduce sampling error and time delay for histopathology diagnosis. We establish biophotonic methods and guidelines to visualize and interpret early epithelial tissue changes that signify disease. Flexible and rigid fiber endomicroscopy instrumentation design parameters feasible for translation towards clinical use are in development.

2010-12-01

177

Calculation of general p-adic Feynman amplitude  

Energy Technology Data Exchange (ETDEWEB)

The general n-point massless p-adic Feynman amplitude with arbitrary parameters of analytic regularization for each line is calculated. This result is presented in the form of a sum over hierarchies of a given graph. The structure of ultraviolet and infrared divergences of p-adic Feynman amplitudes is characterized and the star-triangle uniqueness identity in the p-adic case is derived. (orig.).

1992-10-01

178

International Clean Energy System Using Hydrogen Conversion (WE-NET). subtask 5. Development of hydrogen transport/storage technology (development of tanker for liquid hydrogen); Suiso riyo kokusai clean energy system gijutsu (WE-NET). subtask 5. Suiso yuso chozo gijutsu no kaihatsu (ekitai suiso yuso tanker no kaihatsu)  

Energy Technology Data Exchange (ETDEWEB)

As a part of the WE-NET project, the tanker for liquid hydrogen transport was studied. In fiscal 1996, some experiments and numerical analyses were proposed which are necessary to solve technological issues extracted in fiscal 1995 for heat insulation structure. The issue was roughly classified into vacuum and non-vacuum insulation, and their basic functions and required performance were arranged. Boil-off rate of 0.2-0.4%/d was targeted. The insulation system which applies polyurethane form (PUF) to tank surfaces and injects atmospheric N2 gas into the surrounding hold space, could achieve the targeted insulation performance by PUF of 1m in thickness. The system of vacuum panel insulation and atmospheric N2 gas injection into a hold space required the panel of 500mm in thickness because of the large effect of metallic outer panel material. The system of vacuum hold and PUF panels was faced with the ...

1997-03-01

179

Water-seal vacuum pumps as compact units for deaeration of steam turbine condensers in conventional and nuclear plants  

International Nuclear Information System (INIS)

On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).

180

True and measured outgassing rates of a vacuum chamber with a reversibly adsorbed phase  

Energy Technology Data Exchange (ETDEWEB)

A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small coverage {delta}{theta} from the coverage of a pumping point ...

2000-03-01

181

The Cosmological Constant and Lorentz Invariance of the Vacuum State  

CERN Document Server

One hope to solve the cosmological constant problem is to identify a symmetry principle, based on which the cosmological constant can be reduced either to zero, or to a tiny value. Here, we note that requiring that the vacuum state is Lorentz invariant significantly reduces the theoretical value of the vacuum energy density. Hence, this also reduces the discrepancy between the observed value of the cosmological constant and its theoretical expectation, down from 123 orders of magnitude to 56 orders of magnitude. We find that, at one loop level, massless particles do not yield any contribution to the cosmological constant. Another important consequence of Lorentz symmetry is stabilization of the gravitational hierarchy: the cosmological constant (divided by Newton's constant) does not run as the quartic power of the renormalization group scale, but instead only logarithmically.

2011-01-01

182

Low-range flowmeters for use with vacuum and leak standards  

Energy Technology Data Exchange (ETDEWEB)

Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.

1987-05-01

183

High-vacuum time-resolved laser-induced incandescence of?flame-generated soot  

British Library Electronic Table of Contents (United Kingdom)

We have measured time-resolved laser-induced incandescence of flame-generated soot under high-vacuum conditions (4.1?10?6 mbar) at an excitation wavelength of 532 nm with laser fluences spanning 0.06?0.5 J/cm2. We generated soot in an ethylene/air diffusion flame, introduced it into the vacuum system with an aerodynamic lens, heated it using a pulsed laser with a spatially homogeneous and temporally smooth laser profile, and recorded LII temporal profiles at 685 nm. At low laser fluences LII signal decay rates are slow, and LII signals persist beyond the residence time of the soot particles in the detection region. At these fluences, the temporal maximum of the LII signal increases nearly linearly with increasing laser fluence until reaching a plateau at ?0.18?J/cm2. At higher fluences, th...

2011-01-01

184

Complexity of chaotic fields and standard model parameters  

CERN Document Server

In order to understand the parameters of the standard model of electroweak and strong interactions (coupling constants, masses, mixing angles) one needs to embed the standard model into some larger theory that accounts for the observed values. This means some additional sector is needed that fixes and stabilizes the values of the fundamental constants of nature. In these lecture notes we describe in nontechnical terms how such a sector can be constructed. Our additional sector is based on rapidly fluctuating scalar fields that, although completely deterministic, evolve in the strongest possible chaotic way and exhibit complex behaviour. These chaotic fields generate potentials for moduli fields, which ultimately fix the fundamental parameters. The chaotic dynamics can be physically interpreted in terms of vacuum fluctuations. These vacuum fluctuations are different from those of QED or QCD but coupled with the same moduli fields as QED and QCD ...

2007-01-01

185

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...

2006-09-01

186

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

187

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current densities are ...

2005-01-01

188

An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice  

Energy Technology Data Exchange (ETDEWEB)

The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

2007-10-15

189

The Quantum Vacuum of Complex Media. A Unified Approach to the Dielectric Constant, the Spontaneous Emission and the Zero-Temperature Electromagnetic Pressure  

CERN Document Server

We study from a critical perspective several quantum-electrodynamic phenomena commonly related to vacuum electromagnetic (EM) fluctuations in complex media. We compute the resonance-shift, the spontaneous emission rate, the local density of states and the van-der-Waals-Casimir pressure in a dielectric medium using a microscopic diagrammatic approach. We find, in agreement with some recent works, that these effects cannot be attributed to variations on the energy of the EM vacuum but to variations of the dielectric self-energy. This energy is the result of the interaction of the bare polarizability of the dielectric constituents with the EM fluctuations of an actually polarized vacuum. We have found an exact expression for the spectrum of these fluctuations in a statistically homogeneous dielectric. Those fluctuations turn out to be different to the ones of normal radiative modes. It is the latter that carry the ...

2009-01-01

190

Successful Treatment of Anterior Tracheal Necrosis after Total Thyroidectomy Using Vacuum-Assisted Closure Therapy  

UK PubMed Central (United Kingdom)

Total thyroidectomy involving the adjacent structures of the trachea can cause tracheal damage such as early tracheal necrosis. The authors describe the first case of anterior tracheal necrosis following...Full Text Available

2012-01-01

191

Scheme for Entangling Two Distant Cavity Mirrors  

International Nuclear Information System (INIS)

A scheme is presented for the generation of entangled states for two cavity mirrors. In the scheme each mirror initially in a vacuum state interacts with a weak coherent field, resulting in a photon-number dependent kick. The detection of a photon leaking from the cavities collapses the two mirrors to an entangled state.

2008-04-15

192

Radiation resistance of nylon. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was ...

1983-12-01

193

Quantum chaos in the mixmaster universe  

International Nuclear Information System (INIS)

A Monte Carlo simulation of the vacuum Bianchi type-IX (mixmaster) cosmology yields a significant correlation between large universe volume and high anisotropy. An analog of the model's chaotic classical behavior is seen in the break up of the universe wave function at large volume into fingers in the corners of the minisuperspace anisotropy potential.

194

Metal finishing and vacuum processes groups, Materials Fabrication Division progress report, March-May 1984  

Energy Technology Data Exchange (ETDEWEB)

Progress is reported in fabrication and coating activities being conducted for the weapons program, nuclear test program, nuclear design program, magnetic fusion program, and miscellaneous applications. (DLC)

1984-07-11

195

Inhibited spontaneous emission by a Rydberg atom  

Science.gov (United States)

Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.

1985-11-11

196

Influence of the Atmosphere on a Rubidium Clock's Frequency ...  

Science.gov (United States)

... Figure 3 shows on-orbit (ie, vacuum) frequency aging rates for Milstar rubidium (Rb) clocks, GPS Block IIR Rb clocks, and GPS Block IIA Rb clocks. ...

2007-11-01

197

Impregnation mode in wood plastic composite  

Science.gov (United States)

Bulk monomer MMA was impregnated into simul, a fuel wood of Bangladesh, under vacuum and under normal temperature and pressure conditions in order to compare the mode of impregnation and its effect on various characteristic parameters of wood plastic composites. Methanol (MeOH) was used as the swelling solvent with methylmethacrylate (MMA) at MMA: MeOH = 70:30, v/v. Impregnation of the bulk monomer was very high under vacuum compared to that at normal condition; but the difference of grafting of MMA to the wood cellulose under these two impregnating conditions was much lower as compared to that of the uptakes of impregnating solution MMA + MeOH under these two modes of impregnation. Incorporation of additives to MMA + MeOH has substantially enhanced grafting, tensile strength, bending strength and compression strength of the composite to such an extent that there is virtually very little difference between vacuum ...

1996-12-01

198

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

199

Dust resuspension and transport modeling for loss of vacuum accidents  

Energy Technology Data Exchange (ETDEWEB)

Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined ...

2007-07-01

200

Dust resuspension and transport modeling for loss of vacuum accidents  

International Nuclear Information System (INIS)

Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined ...

2007-10-05

201

Doublet III vacuum vessel neutral beam armor  

Science.gov (United States)

The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.

1979-11-01

202

Direct filtration for recovery of Schistosoma mansoni cercariae in the field  

UK PubMed Central (United Kingdom)

The recovery of schistosome cercariae from natural waters has been limited by variations in turbidity and in the accuracy of recovery with different techniques. A modification of the Rowan vacuum paper...Full Text Available

1973-01-01

203

Critical assessment of the Schroedinger picture of quantum mechanics  

Energy Technology Data Exchange (ETDEWEB)

We provide an example in which the Heisenberg and the Schroedinger pictures of quantum mechanics give different results, thus confirming the statement of P.A.M. Dirac that the two pictures may lead to inequivalent results. We consider a one-dimensional nonrelativistic charged harmonic oscillator (frequency {omega}{sub 0} and mass m), and take into account the action of the radiation reaction and the vacuum electromagnetic forces on the charged oscillator. We show that the Heisenberg picture gives the correct value, {Dirac_h}{omega}{sub 0}/2, for the ground state energy of the harmonic oscillator in both cases of classical and quantized vacuum fields. In the case of the Schroedinger picture, considering classical vacuum fields, and using a simple calculation for the classical radiation reaction force that is valid in the limit of large mass (mc{sup 2} >> {Dirac_h}{omega}{sub 0}), we obtain the value ...

2002-12-16

204

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements done with an atmosphere ...

1981-10-01

205

Beam collimator  

CERN Document Server

A four-block collimator installed on a control table for positioning the alignment reference marks. Designed for use with SPS secondary beams, the collimator operates under vacuum conditions. See Annual Report 1976 p. 121 and photo 7701014.

1977-01-01

206

The vacuum preserving Lie algebra of a classical W-algebra  

International Nuclear Information System (INIS)

We simplify and generalize an argument due to Bowcock and Watts showing that one can associate a finite Lie algebra (the 'classical vacuum preserving algebra') containing the Moebius sl(2) subalgebra to any classical W-algebra. Our construction is based on a kinematical analysis of the Poisson brackets of quasi-fields. In the case of the W_S"G-subalgebra S of a simple Lie algebra G, we exhibit a natural isomorphism between this finite Lie algebra and G whereby the Moebius sl(2) is identified with S. (orig.).

1993-01-01

207

Possible influence of vacuum polarization on Q/sub 1//sub //sub s/ in muon catalyzed D-T fusion  

Energy Technology Data Exchange (ETDEWEB)

The vacuum polarization splitting of the M-shell states in muonic hydrogen can have a profound influence on the muonit de-excitation cascade in deuterium and tritium targets. The cascade also shows sensitive dependence on the precise rate of transfer processes between certain excited muonic deuterium and tritium atoms. Recent experimental data, where a much greater population of the (d..mu..) qs state (1/sub 1//sub //sub s/) was found than previously predicted, can be explained if the transfer rates from the (d..mu..) M-shell are assumed to be strongly suppressed.

1988-12-27

208

Outgassing study of thin films used for poly-SiGe based vacuum packaging of MEMS  

British Library Electronic Table of Contents (United Kingdom)

Thermal desorption spectroscopy (TDS) was used to study outgassing from polycrystalline SiGe (poly-SiGe), SiC and SiO"2 films used for poly-SiGe-based MEMS thin film vacuum package technology. Primary desorption products were found to be H"2, H"2O and CO"2. The CO"2 outgassing could be correlated with CF"4 plasma interface cleaning used for thick SiGe PECVD, which can leave carbon at the CF"4-plasma-cleaned interface.

2011-01-01

209

Effect of protective coatings on the high-temperature fatigue of heat-resistant alloys  

Energy Technology Data Exchange (ETDEWEB)

The fatigue properties of EP539LM alloy with an Al-Nb-Si fused slurry coating and a Co-Cr-Al-Y electron-beam coating are investigated experimentally in vacuum and in air at 900 C. It is found that the protective coatings reduce the fatigue life of the specimens both in vacuum and in air, with the electron-beam coating affecting the fatigue life of the alloy to a lesser degree than the fused slurry coating. The negative effect of the coatings on the fatigue life of the alloy is attributed largely to the properties of the coating material. 7 references.

1986-08-01

210

Discrete vacuum superselection rule in Wightman theory with essentially self-adjoint field operators  

Energy Technology Data Exchange (ETDEWEB)

The main results of earlier work by the author, Sushko, and Khoruzhii describing the algebraic structure of quantum-field systems with (discrete) vacuum superselection rules are generalized to the large class of Wightman theories with essentially self-adjoint field operators (a very strong restriction was imposed on the theory, namely, that the polynomial Op algebra of the Wightman fields /rho/ belongs to the class II, i.e., /rho/ /sub s'/ =/rho/ /sub w'/). It is also shown that the field Op algebra of a Wightman theory with discrete vaccum superselection rule possesses a class II extension.

1986-07-01

211

Development of new three way valve using vacuum for liquid transfer  

International Nuclear Information System (INIS)

The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)

2008-07-01

212

Constraints on extra dimensions from cosmological and terrestrial measurements  

CERN Document Server

If quantum fields exist in extra compact dimensions, they will give rise to a quantum vacuum or Casimir energy. That vacuum energy will manifest itself as a cosmological constant. The fact that supernova and cosmic microwave background data indicate that the cosmological constant is of the same order as the critical mass density to close the universe supplies a lower bound on the size of the extra dimensions. Recent laboratory constraints on deviations from Newton's law place an upper limit. The allowed region is so small as to suggest that either extra compact dimensions do not exist, or their number is about to be tightly constrained by experimental data.

2001-01-01

213

Constraints on Extra Dimensions from Cosmological and Terrestrial Measurements  

CERN Document Server

If quantum fields exist in extra compact dimensions, they will give rise to a quantum vacuum or Casimir energy. That vacuum energy will manifest itself as a cosmological constant. The fact that supernova and cosmic microwave background data indicate that the cosmological constant is of the same order as the critical mass density to close the universe supplies a lower bound on the size of the extra dimensions. Recent laboratory constraints on deviations from Newton's law place an upper limit. The allowed region is so small as to suggest that either extra compact dimensions do not exist, or their properties are about to be tightly constrained by experimental data.

2000-01-01

214

Coke fouling process on the oil refining; Processo de incrustacao por coque no refino do petroleo  

Energy Technology Data Exchange (ETDEWEB)

The heavy crude fraction processing is performed under very high vacuum to minimize thermal cracking which cause coke deposition and damage the equipment. The current tendency is to process heavier oil leading to higher process temperatures and consequently to greater fouling. This situation demands better knowledge fouling process by carbonization. This problem is pronounced in the residual gasoil region of a vacuum distillation unit because it obstructs the recirculation circuits and the spray system with serious environmental and economics implications. This paper review the main correlated published work related to coke generation and fouling and presents a discussion about the works. (author)

2004-07-01

215

A new proof of the Bianchi type IX attractor theorem  

Energy Technology Data Exchange (ETDEWEB)

We consider the dynamics toward the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The 'Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.

2009-04-07

216

A new proof of the Bianchi type IX attractor theorem  

International Nuclear Information System (INIS)

We consider the dynamics toward the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The 'Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.

2009-04-07

217

A new proof of the Bianchi type IX attractor theorem  

CERN Document Server

We consider the dynamics towards the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The `Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.

2009-01-01

218

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

219

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.

1984-10-01

220

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

221

Measurement of the relaxation time of hot electrons in laser-solid interaction at relativistic laser intensities  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.

2006-08-22

222

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

223

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

224

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

225

Failure analysis and defect review using extended accuracy of the CrossBeam {sup registered} Technology  

Energy Technology Data Exchange (ETDEWEB)

The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of instrument combines ...

2005-07-01

226

Ultraviolet upconversion luminescence enhancement in Yb3+/Er3+-codoped Y2O3 nanocrystals induced by tridoping with Li+ ions  

International Nuclear Information System (INIS)

Ultraviolet (UV) upconversion (UC) luminescence in Yb3+/Er3+-codoped yttrium oxide (Y2O3) nanocrystals can be enhanced by orders of magnitude via tridoping further with Li+ ions under diode laser excitation of 970 nm. Sensitized three-photon UC radiations at 390 and 409 nm, corresponding to the 4G11/2?4I15/2 and 4H9/2?4I15/2 of Er3+ ions, respectively, present an enhancement time of about 33 times, which is larger than the 24 times enhancement for the UC green radiation. The UV UC radiation at 320 nm that corresponds to the 2P3/2?4I15/2 of Er3+ ions has also been greatly enhanced. Theoretical calculations interpret that all the observed enhancement times of UV UC radiations arise from the prolonged lifetimes of their intermediate states.

2009-03-01

227

Ultraviolet radiation in Finland  

Energy Technology Data Exchange (ETDEWEB)

Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international activities, especially the EU Environment and Climate Programme`s ...

1996-12-31

228

Space nuclear power requirements for ozone layer modification  

International Nuclear Information System (INIS)

This work estimates the power requirements for using photochemical processes driven by space nuclear power to counteract the Earth's ozone layer depletion. The total quantity of ozone (O_3) in the Earth's atmosphere is estimated to be about 4.7 x 10"3"7 molecules. The ozone production and destruction rates in the stratosphere are both on the order of 4.9 x 10"3"1 molecules/s, differing by a small fraction so that the net depletion rate is about 0.16 to 0.26% per year. The delivered optical power requirement for offsetting this depletion is estimated to be on the order of 3 GW. If the power were produced by satellite reactors at 800 km altitude (orbit decay time #approx# 300 years), some means of efficient power beaming would be needed to deliver the power to stratospheric levels (10--50 km). Ultraviolet radiation at 140--150 nm could have higher absorption rates in O_2 (leading to production of atomic oxygen, which can combine with O_2 to form O_3) than in ozone ...

1992-01-13

229

Second Byurakan spectral sky survey. II. Results for region centered on alpha 09h50m, delta +55 deg 00 arcmin  

Energy Technology Data Exchange (ETDEWEB)

The second list of objects in the Second Biurakan Spectral Sky Survey of the region centered on alpha 09h50m, delta +55 deg 00 arcmin is given. The list contains data on 110 objects and galaxies of a peculiar physical nature and 24 blue stars. The observations were made with the 40-52 arcsec Schmidt telescope of the Biurakan Astrophysical Observatory with a set of three objective prisms using Kodak IIIaJ and IIIaF emulsions sensitized in nitrogen. The area is found to contain 20 quasar candidates and four Seyfert galaxies, 27 blue stellar objects, 24 galaxies with an appreciable ultraviolet continuum, and 39 emission galaxies without appreciable ultraviolet radiation. The surface brightness of the quasars and Seyferts on the considered area down to the limiting magnitude 19.5 M is more than 1.5 per square degree with allowance for the already known quasars. The surface density of emission galaxies is about four per square degree. 7 references.

1984-07-01

230

Photobiological activity of marmesin (5-B-hydroxyisopropyl-4-5 dihydrofurocoumarin) in Chinese hamster V79 cells  

Energy Technology Data Exchange (ETDEWEB)

Marmesin was isolated from the medicinal plant, Afraegle paniculata. Its cytotoxicity and mutagenicity in Chinese hamster V79 cells when sensitized to near ultraviolet (NUV) and long wavelength ultraviolet light or black light (BL) were assayed. Marmesin was extremely cytotoxic in the dark. This cytotoxicity was photoenhanced in NUV and BL; the photoenhanced lethality being higher in NUV than in BL. The LD/sub 50/ of marmesin under NUV and BL photosensitization were 0.002 ..mu..M and (0.012 ..mu..M), respectively. In the absence of NUV and BL, marmesin's LD/sub 50/ was 0.013 ..mu..M.NUV and BL without marmesin were not significantly cytotoxic at the fluence rates of 0.29 W/m/sup 2/ and 4.2 W/m/sup 2/, respectively, for up to 20 min. In contrast to the observed high cytotoxicity of marmesin, its mutagenicity at the HGPRT locus (Asub(z)Gsup(r)) was weak. The implication of this result in the high incidence of skin cancer in Nigeria in ...

1983-10-01

231

Observation of the Far-ultraviolet Continuum Background with SPEAR/FIMS  

CERN Document Server

We present the general properties of the far-ultraviolet (FUV; 1370-1720A) continuum background over most of the sky, obtained with the Spectroscopy of Plasma Evolution from Astrophysical Radiation instrument (SPEAR, also known as FIMS), flown aboard the STSAT-1 satellite mission. We find that the diffuse FUV continuum intensity is well correlated with N_{HI}, 100 $\\mu$m, and H-alpha intensities but anti-correlated with soft X-ray. The strongest correlation is with the H-alpha emission, and the correlation of the diffuse background with the direct stellar flux is weaker than the correlation with other parameters. The continuum spectra are relatively flat. However, a weak softening of the FUV spectra toward some sight lines, mostly at high Galactic latitudes, is found not only in direct-stellar but also in diffuse background spectra. The diffuse background is relatively softer that the direct stellar spectrum. We also find that the diffuse FUV background averaged ...

2010-01-01

232

Multilayer reflective coatings for extreme-ultraviolet lithography  

Energy Technology Data Exchange (ETDEWEB)

Multilayer mirror coatings which reflect extreme ultraviolet (EUV) radiation are a key enabling technology for EUV lithography. Mo/Si multilayers with reflectances of 67.5% at 13.4 nm are now routinely achieved and reflectances of 70 2% at 11.4 nm were obtained with MO/Be multilayers. High reflectance is achieved with careful control of substrate quality, layer thicknesses, multilayer materials, interface quality, and surface termination. Reflectance and film stress were found to be stable relative to the requirements for application to EUV lithography. The run-to-run reproducibility of the reflectance peak position was characterized to be better than 0.2%, providing the required wavelength matching among the seven multilayer-coated mirrors used in the present lithography system design. Uniformity of coating was improved to better than 0.5% across 150 mm diameter substrates. These improvements in EUV multilayer mirror technology will enable us to meet the stringent ...

1998-03-10

233

Mitochondrial genetic damage induced in yeast by a photoactivated furocoumarin in combination with ethidium bromide or ultraviolet light  

International Nuclear Information System (INIS)

Ethidium bromide (EB) and ultraviolet light (UV) in combination are known to produce a synergistic induction of 'petite' mutants in yeast. Two other agents were combined with EB, 3-Carbethoxypsoralene (3 CPs) activated by 365 nm light or #gamma# rays. EB in combination with 3 CPs also resulted in an enhanced production of 'petite' mutants. After the photoaddition of 3 CPs in exponential phase cells, recovery of the 'petite' mutation during dark liquid holding was inhibited by the presence of EB producing an enhanced number of 'petite' mutants. The behavior of mitochondrial antibiotic resistance markers after individual and combined treatments with EB and 3 CPs indicates a random loss of markers after EB and a preferential loss of a certain region for the 3 CPs photoaddition. The combination of the two agents leads to an additivity of total drug marker losses rather than a synergistic loss. The combination of EB with #gamma# rays produced no enhancement in 'petite' ...

234

Low-temperature synthesis and room temperature ultraviolet lasing of nanocrystalline ZnO films  

Energy Technology Data Exchange (ETDEWEB)

Nanocrystalline ZnO films were fabricated via a simple method involving the oxidation of Zn films at a remarkably low temperature of 380 C. X-ray diffraction study confirmed that the Zn films were completely oxidized even at the low temperature of 380 C and the ZnO films fabricated were of polycrystalline wurtzite structure. Room temperature optical pumping using a frequency-quintupled Q-switched Nd:YAG laser ({lambda}=213 nm) exhibited that sharp peaks at around 3.12 eV emerged above excitation powers of {proportional_to}7 MW/cm{sup 2}, demonstrating lasing in the ZnO films. These results represent that the process is a simple, promising approach for fabricating ZnO of sufficient optical performance for use as ultraviolet (UV) light emitters and an alternative UV laser source; both are key components in short-wavelength photonic devices. (orig.)

2005-02-01

235

Detection of H2 Emission from Mira B in UV Spectra from the Hubble Space Telescope  

CERN Document Server

We present ultraviolet spectra of Mira's companion star from the Space Telescope Imaging Spectrograph (STIS) instrument on board the Hubble Space Telescope (HST). The companion is generally assumed to be a white dwarf surrounded by an accretion disk fed by Mira's wind, which dominates the UV emission from the system. The STIS UV spectrum is dominated by numerous, narrow H2 lines fluoresced by H I Ly-alpha, which were not detected in any of the numerous observations of Mira B by the International Ultraviolet Explorer (IUE). The high temperature lines detected by IUE (e.g., C IV 1550) still exist in the STIS spectrum but with dramatically lower fluxes. The continuum fluxes in the STIS spectra are also much lower, being more than an order of magnitude lower than ever observed by IUE, and also an order of magnitude lower than fluxes observed in more recent HST Faint Object Camera objective prism spectra from 1995. Thus, the accretion rate onto Mira ...

2001-01-01

236

Vibrational Circular Dichroism: A developing spectroscopic technique for peptide and protein conformational studies  

International Nuclear Information System (INIS)

Electronic circular dichroism (ECD) of the n-#pi# and #pi# -#pi# transitions of the amide groups in the ultraviolet has become an indispensable tool for qualitative characterization of proteins in solution. Since the existence of such a spectrum (that is, of natural optical activity) comes from the three dimensional interaction of the chromophores in the molecule, CD is exquisitely sensitive to molecular conformation. However, in proteins, the amide transitions available in the near UV are limited in number and are broads and overlapping. Interactions among them yield information about the polymeric backbone, but since such amide electronic excitation are relatively delocalized, the resulting

1996-11-01

237

Ultraviolet Complete Electroweak Model Without a Higgs Particle  

CERN Document Server

An electroweak model with running coupling constants described by an energy dependent entire function is utraviolet complete and avoids unitarity violations for energies above 1 TeV. The action contains no physical scalar fields and no Higgs particle and the physical electroweak model fields are local and satisfy microcausality. The $W$ and $Z$ masses are compatible with a symmetry breaking $SU(2)_L\\times U(1)_Y \\rightarrow U(1)_{\\rm em}$, which retains a massless photon. The vertex couplings possess an energy scale $\\Lambda_W > 1$ TeV predicting scattering amplitudes that can be tested at the LHC.

2010-01-01

238

Two-Loop Virtual Corrections to Drell-Yan Production at order alpha_s alpha^3  

CERN Document Server

The Drell-Yan mechanism for the production of lepton pairs is one of the most basic processes for physics studies at hadron colliders. It is therefore important to have accurate theoretical predictions. In this work we compute the two-loop virtual mixed QCD x QED corrections to Drell-Yan production. We evaluate the Feynman diagrams by decomposing the amplitudes into a set of known master integrals and their coefficients, which allows us to derive an analytical result. We also perform a detailed study of the ultraviolet and infrared structure of the two-loop amplitude and the corresponding poles in epsilon.

2011-01-01

239

The wavelength dependence of ultraviolet enhanced reactivation in a mammalian cell-virus system  

International Nuclear Information System (INIS)

The effect of UV radiation in the wavelength region 230 nm to 302 nm on the ability of an irradiated mammalian cell to reactivate UV-irradiated mammalian virus was tested. An action spectrum for radiation enhanced reactivation (RER) is presented. The shape of the action spectrum points to a combined nucleic acid-protein target for UV radiation effects on this cellular parameter. An analysis of the results of others involving the biochemical and photobiological events involved in RER does not allow us to distinguish which macromolecule is the major contributor to this effect. Studies involving an analogous phenomenon in bacteris (Weigle reactivation) imply that RER and WR amy involve similar mechanisms. (author).

240

Spectroscopy of color centers in yttrium-aluminium perovskite crystals  

International Nuclear Information System (INIS)

The color centers, which are generated in yttrium-aluminium perovskite (YAP):Nd(1 at.%) and YAP:Er(50 at.%) crystals under the influence of ultraviolet and #gamma#-irradiation, have been studied by absorption spectroscopy. The generated color centers are both stable and transient at room temperature. It is shown that the transient color centers are mainly responsible for the decrease of laser generation efficiency of Nd:YAP and YAP:Er irradiated crystals, although physical mechanisms leading to efficiency decrease are different in these materials. (orig.)

1998-07-24

241

Solid-state ozone synthesis by energetic ions  

International Nuclear Information System (INIS)

We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.

1999-08-02

242

Photoluminescence and cathodoluminescence properties of Tb3+ activated Sr3AlO4F emitting-color tunable phosphor  

British Library Electronic Table of Contents (United Kingdom)

Tb3+-activated Sr3AlO4F phosphors were synthesized by a high-temperature solid-state reaction method. The investigation of photoluminescence and cathodoluminescence indicates that these phosphors can be effectively excited by ultraviolet light and low-voltage electron beam. The phosphors exhibit a tunable-green emission. The luminescence behaviors are explained by the site occupancy of Tb3+ ions in the host crystal and the cross-relaxation of 5D3 to 5D4 state.

2011-01-01

243

Photoluminescence and cathodoluminescence properties of Tb3+ activated Sr3AlO4F emitting-color tunable phosphor  

Science.gov (United States)

Tb3+-activated Sr3AlO4F phosphors were synthesized by a high-temperature solid-state reaction method. The investigation of photoluminescence and cathodoluminescence indicates that these phosphors can be effectively excited by ultraviolet light and low-voltage electron beam. The phosphors exhibit a tunable-green emission. The luminescence behaviors are explained by the site occupancy of Tb3+ ions in the host crystal and the cross-relaxation of 5D3 to 5D4 state.

2011-03-01

244

Photochemical generation of E' centre from Si-H in amorphous SiO2 under pulsed ultraviolet laser radiation  

CERN Document Server

In situ optical absorption spectroscopy was used to study the generation of E' centres in amorphous SiO_2 occurring by photo-induced breaking of Si-H groups under 4.7eV pulsed laser radiation. The dependence from laser intensity of the defect generation rate is consistent with a two-photon mechanism for Si-H rupture, while the growth and the saturation of the defects are conditioned by their concurrent annealing due to reaction with mobile hydrogen arising from the same precursor. A rate equation is proposed to model the kinetics of the defects and tested on experimental data.

2006-01-01

245

Partial inhibition of in vitro pollen germination by simulated solar ultraviolet-B radiation  

Energy Technology Data Exchange (ETDEWEB)

Pollen from four temperate-latitude taxa were treated with UV radiation in a portion of the UV-B (280-320 nm) waveband during in vitro germination. Inhibition of germination was noted in this pollen compared to samples treated identically except for the exclusion of the UV-B portion of the spectrum. Levels similar to maximum solar UV-B found in temperate-latitude areas failed to inhibit pollen germination significantly, while levels similar to maximum solar UV-B found in equatorial alpine locations caused partial inhibition of germination in three of the four taxa examined.

1984-01-01

246

Optimum plasma conditions for the efficient high-order harmonic generation in platinum plasma  

International Nuclear Information System (INIS)

We studied the optimum plasma conditions that are required for efficient high-order harmonic generation in platinum plume. Harmonics up to the 49th order (?=16.32 nm) are analyzed under various conditions of laser-plasma interaction. Time-resolved ultraviolet spectra of platinum plasma at both optimum and nonoptimum conditions of harmonic generation are presented. We calculated the ionization states of the plasma, free electron density, and singly charged ion density at different prepulse intensities and compared them with experimental results.

2007-06-01

247

Endomicroscopy imaging of epithelial structures using tissue autofluorescence  

Science.gov (United States)

We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.

2011-04-01

248

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

249

FORMATION EPOCHS, STAR FORMATION HISTORIES, AND SIZES OF MASSIVE EARLY-TYPE GALAXIES IN CLUSTER AND FIELD ENVIRONMENTS AT z = 1.2: INSIGHTS FROM THE REST-FRAME ULTRAVIOLET  

International Nuclear Information System (INIS)

We derive stellar masses, ages, and star formation histories (SFHs) of massive early-type galaxies in the z = 1.237 RDCS1252.9-2927 cluster and compare them with those measured in a similarly mass-selected sample of field contemporaries drawn from the Great Observatories Origin Deep Survey South Field. Robust estimates of these parameters are obtained by comparing a large grid of composite stellar population models with 8-9 band photometry in the rest-frame near-ultraviolet, optical, and IR, thus sampling the entire relevant domain of emission of the different stellar populations. Additionally, we present new, deep U-band photometry of both fields, giving access to the critical far-ultraviolet rest frame, in order to empirically constrain the dependence of the most recent star formation processes on the environment. We also analyze the morphological properties of both samples to examine the dependence of their scaling relations on their mass ...

2010-01-20

250

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

251

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

252

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

253

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

254

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

255

SOME RECENT DETERMINATIONS OF ATOMIC MASSES IN THE STRONTIUM-ZIRCONIUM REGION  

Science.gov (United States)

A large double-focusing mass spectrometer was used to obtain new values for the masses of Sr/sup 86/, Sr/sup 88/, and Zr/sup 90/. Mass differences calculated from these values are found to be in better agreement with nuclear transmutation information than were previous mass spectroscopically derived values. (auth)

1960-06-01

256

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

257

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

258

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

259

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

260

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

261

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

262

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

263

Highly efficient ion source for analysis of transuranium elements  

Energy Technology Data Exchange (ETDEWEB)

Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.

1987-01-01

264

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

265

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

266

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

267

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

268

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

269

Cylinder drift chamber with three-dimensional data output  

Science.gov (United States)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

1995-03-01

270

Cylinder drift chamber with three-dimensional data output  

International Nuclear Information System (INIS)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

271

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

272

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

273

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

274

Application of neural networks to pulse-shape analysis of Bragg curves  

Energy Technology Data Exchange (ETDEWEB)

A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.

2006-01-15

275

An emulation and management software for MCA with 64 independent coded inputs  

International Nuclear Information System (INIS)

A Software for the Neutron Scattering time-of-flight Spectrometer with 64 independent coded inputs is preset. It performs data acquirement and management. The work platform of the software is the Windows 98 and programmed with Visual Basic 6.0. It supports 64 x 1024 channel analyzer computer system. The friendly interface, convenient operation and high reliability are advantages of the Software

2000-09-07

276

Tests show ability of vacuum circuit breaker to interrupt fast transient recovery voltage rates of rise of transformer secondary faults  

Energy Technology Data Exchange (ETDEWEB)

A Vacuum Circuit Breaker demonstrated its ability to interrupt short circuits with faster than normal rates of rise of Transient Recovery Voltage (TRV) at levels greater than those produced by most transformer secondary faults. Two recent exploratory test programs evaluated the interrupting ability of a 15kV Vacuum Circuit Breaker containing interrupters of the rotating arc type with contacts made from a Chromium-Copper powder metal mixture. The interrupting conditions covered a wide range of currents from 10% to 130% of the 28kA rated short circuit current of the tested circuit breaker and a wide range of TRV rates of rise, including the relatively slow rate of rise, normally used in testing and found in most indoor circuit breaker applications; two faster rates of rise equaling and exceeding those found in a known power plant transformer secondary protection application; and the fastest rates of rise possible in the laboratory which exceed ...

1994-12-31

277

Summary of ACSL Simulations of the MSRE Auxiliary Charcoal Bed Vacuum System  

Energy Technology Data Exchange (ETDEWEB)

The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance ...

2000-10-26

278

Interrupting characteristics of series connection of thermal puffer gas circuit breaker and vacuum circuit breaker. Netsu paffa gata gas shadanbu to shinku shadanbu no chokuretsu shadan tokusei  

Energy Technology Data Exchange (ETDEWEB)

Puffer gas circuit breaker used widely in interrupters with from middle capacity to large capacity does not keep away from reacting force of the puffer with high functions in principle and there is a limit in low operation. In this study, aiming at low operation of the interrupters, in order to clarify the basic motions of hybrid circuit interrupter that is the combination of thermal puffer gas circuit breaker and vacuum circuit breaker, the interrupting ability of simple thermal puffer gas breaker and the voltage sharing characteristics in the cases of series connection with the vacuum circuit breaker are studied. The results of the study are as follows. In comparing terminal short circuit accident interrupting ability of single flow typed thermal puffer gas breaker with that of double flow typed thermal puffer gas breaker, the interrupting ability of the double flow typed thermal puffer gas breaker may be improved. It is also clarified that ...

1993-12-20

279

Turning the Moon into a Solar Photovoltaic Paradise  

Science.gov (United States)

Lunar resource utilization has focused principally on the extraction of oxygen from the lunar regolith. A number of schemes have been proposed for oxygen extraction from Ilmenite and Anorthite. Serendipitously, these schemes have as their by-products (or more directly as their "waste products"), materials needed for the fabrication of thin film silicon solar cells. Thus lunar surface possesses both the elemental components needed for the fabrication of silicon solar cells and a vacuum environment that allows for vacuum deposition of thin film solar cells directly on the surface of the Moon without the need for vacuum chambers. In support of the US space exploration initiative a new architecture for the production of thin film solar cells on directly on the lunar surface is proposed. The paper discusses experimental data on the fabrication and properties of lunar glass substrates, evaporated lunar regolith thin films ...

2006-01-01

280

The quantum Zeno paradox revisited: the time evolution for a two-level system interacting with a reservoir  

Energy Technology Data Exchange (ETDEWEB)

We revisited the quantum Zeno paradox, which claims that a generic quantum system prepared in a state which is not an eigenstate of the Hamiltonian operator and is continuously observed never decays. Since any perfectly isolated quantum system always interact with a vacuum field, we analyze the possibility of using this fact to solve the above mentioned conceptual problem. Therefore we discuss a two-level system or qubit-Bose field interaction Hamiltonians. We consider the quantum dynamics of this two-level system, prepared in the excited state interacting with a Bose field prepared in the Poincare invariant vacuum state. Using a first-order approximation in time-dependent perturbation theory, we evaluate the probability of spontaneous decay of the two-level system driven by the vacuum field. This probability is evaluated for a finite time interval. Using the standard argument to obtain the quantum Zeno paradox, we consider ...

2006-12-15

281

Performance of solid-lubricated ceramic ball bearings at high-temperature in a vacuum; Kotai junkatsu ceramics tamajikuuke no shinkuchu, koonka ni okeru seino  

Energy Technology Data Exchange (ETDEWEB)

Aiming to realize ball bearings operable in a vacuum and under high temperature, silicon nitride (Si3N4) ceramic ball bearings were tested. The tested ball bearings were angular contact ball bearings composed of silicon nitride with sputtered molybdenum disulfide coating using a retainer of hot-pressed self-lubricating composite material. The time variation of the frictional torque was examined for the operations under the conditions at 500{degree}C in a vacuum at a rotational speed of 600 rpm and 50N thrust load for 5{times}10{sup 7}revolutions (1400 hours) and for 1.5{times}10{sup 8}revolutions (4200 hours). Excellent tribological performance was obtained. The ball bearings are lubricated with the molybdenum disulfide film at the initial stage of the operation and with a transfer film formed from the retainer material to the balls. In a test at 650{degree}C, low and stable frictional torque was observed up to 500 hours of operation as of the ...

1996-04-05

282

On the plasma rotation in a straight magnetized filter of a pulsed vacuum arc  

International Nuclear Information System (INIS)

In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify the magnitude of the plasma rotation. It is found that at the ...

2007-01-21

283

Lattice calculation of nonleptonic charm decays  

Energy Technology Data Exchange (ETDEWEB)

The decays of charmed mesons into two body nonleptonic final states are investigated. Weak interaction amplitudes of interest in these decays are extracted from lattice four-point correlation functions using a effective weak Hamiltonian including effects to order G{sub f} in the weak interactions yet containing effects to all orders in the strong interactions. The lattice calculation allows a quantitative examination of non-spectator processes in charm decays helping to elucidate the role of effects such as color coherence, final state interactions and the importance of the so called weak annihilation process. For D {yields} K{pi}, we find that the non-spectator weak annihilation diagram is not small, and we interpret this as evidence for large final state interactions. Moreover, there is indications of a resonance in the isospin {1/2} channel to which the weak annihilation process contributes exclusively. Findings from the lattice calculation are compared to results from the continuum ...

1991-11-01

284

High frequency limit of vacuum microelectronic grating free-electron laser  

International Nuclear Information System (INIS)

The dependencies that limit high frequency operation of a vacuum microelectronic grating free-electron laser are examined. The important parameters are identified as the electron beam energy, emittance, and generalized perveance. The scaling of power with emittance and frequency is studied in the far-infrared spectral range using a modified scanning electron microscope (SEM) and submillimeter diffraction gratings. The SEM is suited to the task of generating and positioning a low emittance (10"-"2#pi#-mm-mrad), low current (100 #mu#A), but high current density (50-500 A cm"-"2) electron beam. It has been used to demonstrate the spontaneous emission process known as the Smith-Purcell effect. A vacuum microelectronic grating free-electron laser has the potential of generating radiation throughout the entire far-infrared spectral range which extends from approximately 10 to 10"3#mu#m. An introduction to the theory, initial results, and details of ...

1995-08-21

285

Vessel elements present in the secondary xylem of Trochodendron and Tetracentron (Trochodendraceae)  

British Library Electronic Table of Contents (United Kingdom)

For almost 150 years, the two monotypic genera Trochodendron and Tetracentron (Trochodendraceae) have been considered to share an unusual and primitive feature in angiosperms - the lack of vessels in their wood. Therefore, they have been classified in a basal position in the angiosperms. Our observations by light microscopy, low-vacuum environmental scanning electron microscopy (ESEM) and high-vacuum scanning electron microscopy (SEM) both in fresh and FAA-fixed materials consistently showed the presence of tracheary elements differentiated into two types in both genera. In Trochodendron, the tracheary elements can be divided into perforate vessel elements and imperforate fiber-tracheids and tracheids. The vessel elements show end and lateral walls. The pits on the end walls are elongate- ...

2011-01-01

286

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

287

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and ...

2008-01-01

288

Spontaneous excitation of an accelerated atom in a spacetime with a reflecting plane boundary  

Science.gov (United States)

We study a two-level atom in interaction with a real massless scalar quantum field in a spacetime with a reflecting boundary. The presence of the boundary modifies the quantum fluctuations of the scalar field, which in turn modifies the radiative properties of atoms. We calculate the rate of change of the mean atomic energy of the atom for both inertial motion and uniform acceleration. It is found that the modifications induced by the presence of a boundary make the spontaneous radiation rate of an excited inertial atom oscillate near the boundary and this oscillatory behavior may offer a possible opportunity for experimental tests for geometrical (boundary) effects in flat spacetime. While for accelerated atoms, the transitions from ground states to excited states are found to be possible even in a vacuum due to changes in the vacuum fluctuations induced by both the presence of the boundary and the acceleration of atoms, and this can be ...

2005-09-15

289

Special features of control and protection for large saturated steam turbines  

International Nuclear Information System (INIS)

For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).

290

Size determination of Acipenser ruthenus spermatozoa in different types of electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde...

2010-01-01

291

Secondary electron yield measurements from thin surface coatings for NLC electron cloud reduction  

CERN Document Server

In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.

2004-01-01

292

Recent advance of focused ion beam technology in maskless deposition and patterning  

International Nuclear Information System (INIS)

The present article will review recent advances in focused ion beam (FIB) technology. With increasing demands for scale of integration, microfabrication technology is becoming more important and various new microfabrication tools and processing techniques are desired. FIB is one of the promising tools for future microfabrication technology. This provides maskless patterning capability, which is of importance for process simplification, nanofabrication and in the development of in situ vacuum processing. In situ vacuum processing systems are being developed by combining FIB and a molecular beam epitaxy system. Radiation damage may limit applications of FIB. However, it was demonstrated that low energy FIB (<1 keV) with very high brightness was reached and promising results for low damage processing have been obtained. (orig.).

293

Particulate composites in the TiC-TiYTZP system  

International Nuclear Information System (INIS)

Twelve powders of TiO_2-Y_2O_3-ZrO_2 solid solution of the methodically changed composition were prepared by a coprecipitation-calcination technique. After mixing with phenol-formaldehyde resin, the powders were calcinated for 2 hours at 1200"oC in vacuum. The resultant composite powders contained TiC and non-reacted carbon. Green compacts were sintered in vacuum at 1500"oC for 2 hours. A temperature increase was stopped at 1200"oC to react remains of carbon. There were two carbides in the composites TiC and ZrC. TiC non-stoichiometry depended on carbon content in the system. Phase composition of the depended on of titania and yttria in zirconia solid solution. The majority of the samples showed two tetragonal zirconia phases differing in lattice parameter and tetragonality. (author)

2004-09-12

294

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

295

Mechanism of electrical breakdown of gases for pressures from 10?9 to 1 bar and inter-electrode gaps from 0.1 to 0.5 mm  

Science.gov (United States)

This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-electrode gap, i.e. in the vicinity of the Paschen minimum. In this area of pressure and inter-electrode gap values, breakdown occurs either through gas or vacuum mechanisms, and also the so called anomalous Paschen effect appears. Electrical breakdown of electropositive, electronegative and noble gases has been investigated theoretically, experimentally and numerically. Based on the results obtained, regions in which particular breakdown mechanisms appear have been demarcated. Special attention has been devoted to the anomalous Paschen effect as well as to the avalanche vacuum breakdown mechanism.

2007-08-01

296

Mechanism of electrical breakdown of gases for pressures from 10"-"9 to 1 bar and inter-electrode gaps from 0.1 to 0.5 mm  

International Nuclear Information System (INIS)

This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-electrode gap, i.e. in the vicinity of the Paschen minimum. In this area of pressure and inter-electrode gap values, breakdown occurs either through gas or vacuum mechanisms, and also the so called anomalous Paschen effect appears. Electrical breakdown of electropositive, electronegative and noble gases has been investigated theoretically, experimentally and numerically. Based on the results obtained, regions in which particular breakdown mechanisms appear have been demarcated. Special attention has been devoted to the anomalous Paschen effect as well as to the avalanche vacuum breakdown mechanism.

2007-08-01

297

Inflation and reheating in Bianchi type-IX cosmology  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the Bianchi type-IX homogeneous space, we set up a system of coupled equations for the cosmic scale factors, scalar field, and radiative energy density. At the tree level, the equations are written in a self-consistent, Hartree-Fock form. For phi/sup 4/ theory, the system of nine first-order differential equations is solved numerically for a varying ratio of the energy of anisotropy to the vacuum energy. As the vacuum energy increases, there appears to be less reheating, since the energy of anisotropy is more efficiently converted into isotropic expansion. If the energy of anisotropy is large enough, the inflationary phase is prevented. In this case, a series of cosmological phase transitions will take place each time the square of the effective mass changes its sign.

1985-02-15

298

Inflation and reheating in Bianchi type-IX cosmology  

International Nuclear Information System (INIS)

Within the framework of the Bianchi type-IX homogeneous space, we set up a system of coupled equations for the cosmic scale factors, scalar field, and radiative energy density. At the tree level, the equations are written in a self-consistent, Hartree-Fock form. For phi"4 theory, the system of nine first-order differential equations is solved numerically for a varying ratio of the energy of anisotropy to the vacuum energy. As the vacuum energy increases, there appears to be less reheating, since the energy of anisotropy is more efficiently converted into isotropic expansion. If the energy of anisotropy is large enough, the inflationary phase is prevented. In this case, a series of cosmological phase transitions will take place each time the square of the effective mass changes its sign.

299

In situ ultrahigh vacuum transmission electron microscopy studies of palladium silicide island formation on silicon (111) 7x7 surface  

International Nuclear Information System (INIS)

Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.

2003-01-22

300

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.

1981-01-01

301

Field theory description of neutrino oscillations  

CERN Document Server

We review various field theory approaches to the description of neutrino oscillations in vacuum and external fields. First we discuss a relativistic quantum mechanics based approach which involves the temporal evolution of massive neutrinos. To describe the dynamics of the neutrinos system we use exact solutions of wave equations in presence of an external field. It allows one to exactly take into account both the characteristics of neutrinos and the properties of an external field. In particular, we examine flavor oscillations an vacuum and in background matter as well as spin flavor oscillations in matter under the influence of an external electromagnetic field. Moreover we consider the situation of hypothetical nonstandard neutrino interactions with background fermions. In the case of ultrarelativistic particles we reproduce an effective Hamiltonian which is used in the standard quantum mechanical approach for the description of neutrino ...

2010-01-01

302

Effects of quantum vacuum fluctuations of the electric field on DNA condensation  

British Library Electronic Table of Contents (United Kingdom)

By assuming that not only counter-ions but DNA molecules as well are thermally distributed according to a Boltzmann law, we propose a modified Poisson-Boltzmann equation, at the classical level, as a starting point to compute the effects of quantum fluctuations of the electric field on the interaction among DNA-cation complexes. The latter are modeled here as infinite one-dimensional wires (?-functions). Our goal is to single out such quantum-vacuum-driven interaction from the counterion-induced and water-related interactions. We obtain a universal, frustration-free Casimir-like (codimension 2) interaction that extensive numerical analysis show to be a good candidate to explain the formation and stability of DNA aggregates. Such Casimir energy is computed for a variety of configurations of...

2011-01-01

303

Effect of different treatments on acid centers of very high silicon zeolites studied by ir spectroscopy  

Science.gov (United States)

Using the infrared spectroscopy method, we have studied the effect of thermal dehydration (under vacuum and in air) and treatment with water vapor on the acid centers of very high silicon zeolites of the ZSM type. We have shown that dehydration under vacuum and in air completely and irreversibly removes the OH groups at 1120/sup 0/K, while treatment with water vapor removes these groups at 770/sup 0/K. The Lewis acid centers of dehydrated zeolites (represented by two types of centers) are more heat-stable than the Bronsted acid centers, but the vapor treatment at 1020/sup 0/K leads to the disappearance of the Lewis acid centers. In this work, we discuss the reasons for destruction of the acid centers of the zeolites under different treatment conditions.

1986-08-01

304

Disorder on the landscape  

CERN Document Server

Disorder on the string theory landscape may significantly affect dynamics of eternal inflation leading to the possibility for some vacua on the landscape to become dynamically preferable over others. We systematically study effects of a generic disorder on the landscape starting by identifying a sector with built-in disorder -- a set of de Sitter vacua corresponding to compactifications of the Type IIB string theory on Calabi-Yau manifolds with a number of warped Klebanov-Strassler throats attached randomly to the bulk part of the Calabi-Yau. Further, we derive continuum limit of the vacuum dynamics equations on the landscape. Using methods of dynamical renormalization group we determine the late time behavior of the probability distribution for an observer to measure a given value of the cosmological constant. We find the diffusion of the probability distribution to significantly slow down in sectors of the landscape where the number of nearest neighboring vacua ...

2008-01-01

305

Development of ball bearings with solid film for high-vacuum, high-temperature, high-speed application  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the experimental results of long-life solid lubricated ball bearings tested under high-vacuum of 10 exp -4 Pa, high-temperature of 300 C, and high-speed (9000 rpm) conditions. For full ball-type bearings, the thin soft metals, either Ag or Pb, which were coated on the races and balls, appeared to have good torque properties. However, the durability of such bearings was less than 300 hours. The transfer films from the lamellar solid MoS2 and metal composite retainers improved the torque and wear properties. For ceramic, i.e., silicon nitride, balls used with steel rings, wear occurred on the inner rings. All ceramic bearings with composite retainers showed improved torque and wear properties. 18 refs.

1993-04-01

306

Characterization of vacuum-multifoil insulation for long-life thermal batteries  

Energy Technology Data Exchange (ETDEWEB)

The use of vacuum multifoil (VMF) container for thermal insulation in long-life thermal batteries was investigated in a proof-of-concept demonstration. An InvenTek-designed VMF container 4.9 inches in diameter by 10 inches long was used with an internally heated aluminum block, to simulate a thermal-battery stack. The block was heated to 525 C or 600 C and allowed to cool while monitoring the temperature of the block and the external case at three locations with time. The data indicate that it should be possible to build an equivalent-sized thermal battery that should last up to six hours, which would meet the requirements for a long-life sonobuoy application.

2000-04-17

307

Biaxial Bianchi type 9 quantum cosmology  

Energy Technology Data Exchange (ETDEWEB)

We investigate the quantum cosmology of spatially homogeneous models with compact spatial sections admitting a u(2) isometry algebra. The metric ansatz in these models is that of Bianchi type IX with two scale factors set to be equal. We apply the Hartle-Hawking no-boundary path integral prescription and find the semi-classical contributions to the wave function. Exact formulae are obtainable for certain contributions and otherwise the limits of large and small anisotropy (for the pure vacuum case) and large spatial volume or small anisotropy (for the case with a positive cosmological constant) are considered. For the pure vacuum case we find no semiclassical components which would correspond to Lorentzian universes. For the case with a cosmological constant the Hartle-Hawking boundary conditions formally constrain one of the parameters in the Lorentzian solutions to be purely imaginary. Possible interpretations of this imaginary parameter are ...

1990-04-01

308

Biaxial Bianchi type 9 quantum cosmology  

International Nuclear Information System (INIS)

We investigate the quantum cosmology of spatially homogeneous models with compact spatial sections admitting a u(2) isometry algebra. The metric ansatz in these models is that of Bianchi type IX with two scale factors set to be equal. We apply the Hartle-Hawking no-boundary path integral prescription and find the semi-classical contributions to the wave function. Exact formulae are obtainable for certain contributions and otherwise the limits of large and small anisotropy (for the pure vacuum case) and large spatial volume or small anisotropy (for the case with a positive cosmological constant) are considered. For the pure vacuum case we find no semiclassical components which would correspond to Lorentzian universes. For the case with a cosmological constant the Hartle-Hawking boundary conditions formally constrain one of the parameters in the Lorentzian solutions to be purely imaginary. Possible interpretations of this imaginary parameter are ...

309

An in situ observation of the growth kinetics and stress relaxation Pd sub 2 Si thin films on Si(111)  

Energy Technology Data Exchange (ETDEWEB)

The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.

1990-04-15

310

An PB?-73C vacuum spark gap with a control circuit based on an inductive energy storage  

British Library Electronic Table of Contents (United Kingdom)

The design and operating principle of a small (50 mm in diameter and 100 mm in height) ???-73C vacuum spark gap are described. It is shown that it can be efficiently switched using a control circuit with a low (?900 V) supply voltage, which is based on an inductive energy storage and a diode opening switch that forms a high-voltage igniting pulse with a rise time of nanosecond duration. The ???-73C switching process is investigated at different rise times of igniting voltage pulses and different igniting current amplitudes. The results of tests of the spark gap operating in regimes of switching current pulses with an amplitude of 12 kA and a rise time of 800 ns are presented.

2011-01-01

311

An in situ observation of the growth kinetics and stress relaxation Pd sub 2 Si thin films on Si(111)  

Science.gov (United States)

The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.

1990-04-15

312

A pump-probe XFEL particle injector for hydrated samples  

CERN Document Server

We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.

2011-01-01

313

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built and tested. The results of these test, ...

2004-10-13

314

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

315

Synthesis of novel high-voltage cathode material LiCoPO{sub 4} via rheological phase method  

Energy Technology Data Exchange (ETDEWEB)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the better crystallized ...

2010-07-23

316

Synthesis of novel high-voltage cathode material LiCoPO4 via rheological phase method  

International Nuclear Information System (INIS)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized rheological phase ...

2010-07-23

317

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...

2000-05-01

318

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and non-statistical ...

319

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University lead slowing-down ...

1992-01-01

320

Recent neutron scattering work at the University of Lowell  

International Nuclear Information System (INIS)

Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.

1981-11-23

321

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1992-01-01

322

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1991-10-01

323

High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control  

Energy Technology Data Exchange (ETDEWEB)

High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing nozzle and a quadrupolar mass ...

2004-03-31

324

Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states  

International Nuclear Information System (INIS)

The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of ...

325

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

Energy Technology Data Exchange (ETDEWEB)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

1992-06-01

326

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

International Nuclear Information System (INIS)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

327

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)

2004-12-15

328

Atomic beam spectrometer using a LiF analyzer crystal  

International Nuclear Information System (INIS)

An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an incident energy of 23 ...

1978-01-01

329

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...

2000-03-21

330

Use of a new time of flight aerosol mass spectrometer for ground and airborne measurements of biogenically produced organic aerosols  

Environmental Research Database

DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...

331

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

332

Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction  

International Nuclear Information System (INIS)

The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.

2007-09-01

333

Spectra of positrons and electrons emitted in "8"8Y decay  

International Nuclear Information System (INIS)

The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.

334

Soil gamma ray spectrometry of the Buquira river basin, SP, Brazil; Gamametria de solos da bacia do rio Buquira, SP, Brazil  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)

2002-12-01

335

Search for K_S K_S in J/psi and psi(2S) decays  

CERN Document Server

The CP violating processes J/psi-->K_S K_S and psi(2S)-->K_S K_S are searched for using samples of 58 million J/psi and 14 million psi(2S) events collected with the Beijing Spectrometer at the Beijing Electron Positron Collider. No signal is observed, and upper limits on the decay branching ratios are determined to be BR(J/psi-->K_S K_S) K_S K_S) < 4.6x10^{-6} at the 95% confidence level.

2004-01-01

336

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

337

Refractometry of organosilica microspheres  

CERN Document Server

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.

2007-01-01

338

Radon grab sampling in water by means of radon transfer in activated charcoal collectors  

Energy Technology Data Exchange (ETDEWEB)

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

1999-08-01

339

Quasi-elastic electron scattering by GaAs surface  

International Nuclear Information System (INIS)

Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).

1994-03-20

340

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

341

Production of cumulative pions and kaons  

International Nuclear Information System (INIS)

#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.

1988-06-14

342

Observation of p pbar pi^0 and p pbar eta in psi' decays  

CERN Document Server

The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.

2005-01-01

343

Near-threshold production of {omega}-mesons in the pn{yields}d{omega} reaction  

Energy Technology Data Exchange (ETDEWEB)

The first measurement of the pn{yields}d{omega} total cross-section has been achieved at mean excess energies Q{approx}28 and 57 MeV by using a deuterium cluster-jet target. The momentum of the fast deuteron was measured in the ANKE spectrometer at COSY-Juelich and that of the slow ''spectator'' proton (p{sub sp}) from the pd{yields}p{sub sp}d{omega} reaction in a silicon telescope placed close to the target. The cross-sections lie above those measured for pp{yields}pp{omega} but seem to be below theoretical predictions. (orig.)

2004-09-01

344

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

345

Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight  

CERN Document Server

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.

2008-01-01

346

Low-energy fission of nuclei lighter than Hg  

International Nuclear Information System (INIS)

The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.

347

Level structure of the doubly-odd /sup 242/Am nucleus  

Energy Technology Data Exchange (ETDEWEB)

The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.

1988-06-01

348

Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.

1983-03-01

349

Improved measurement of the branching ratio of J/psi-->K_S K_L  

CERN Document Server

The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.

2004-01-01

350

Failure analysis on a ruptured petrochemical pipe  

Energy Technology Data Exchange (ETDEWEB)

The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

2010-08-15

351

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

352

Electromagnetic decay properties of multiparticle-hole states in neutron deficient Mo and Tc isotopes  

Energy Technology Data Exchange (ETDEWEB)

Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).

1995-12-31

353

Effect of the size of an artificial neural network used as pattern identifier  

Energy Technology Data Exchange (ETDEWEB)

A novel way to extract relevant parameters associated with the outgoing ions from nuclear reactions, obtained by digitizing the signals provided by a Bragg curve spectrometer (BCS) is presented. This allowed the implementation of a more thorough pulse-shape analysis. Due to the complexity of this task, it was required to take advantage of new and more powerful computational paradigms. This was fulfilled using a back-propagation artificial neural network (ANN) as a pattern identifier. Over training of ANNs is a common problem during the training stage. In the performance of the ANN there is a compromise between its size and the size of the training set. Here, this effect will be illustrated in relation to the problem of Bragg Curve (BC) identification. (Author)

2003-07-01

354

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

355

Basic Design Report of DC-TOF Inelastic Neutron Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

2006-04-15

356

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

357

Wastewater treatment; Abwasserreinigung  

Energy Technology Data Exchange (ETDEWEB)

The methods introduced for the field of cleaning waste water can be classified under various processes. Chemical oxidation is done with ozone, hydrogen peroxide and ultraviolet irradiation with subsequent biological decomposition. Another method is ultra-filtration with recovery of valuable materials or waste water ponds with algae biomass to decompose ammonium compounds, nitrates and phosphates. (EF) [Deutsch] Die auf dem Gebiet der Abwasserreinigung vorgestellten Methoden kann man in verschiedene Verfahren einordnen. Die chemische Oxidation erfolgt mit Ozon, Wasserstoff-Peroxid, UV Bestrahlung und anschliessenden biologischen Abbau. Eine andere Methode ist die Ultrafiltration mit Rueckgewinnung von Wertstoffen oder Abwasserteiche mit Algenbiomasse zum Abbau von Ammoniumverbindungen, Nitraten und Phosphaten. (EF)

1994-11-01

358

Use of polarized light microscopy in porcine reproductive technologies  

British Library Electronic Table of Contents (United Kingdom)

The meiotic spindle in the oocyte is composed of microtubules and plays an important role during chromosome alignment and separation at meiosis. Polarized light microscopy (PLM) could be useful for a non-invasive evaluation of the meiotic spindle and may allow removal of nuclear structures without fluorochrome staining and ultraviolet exposure. In this study, PLM was used to assess its potential application in porcine reproductive technologies. The objectives of the present study were to assess the efficiency of PLM to detect microtubule-polymerized protein in in vitro-matured porcine oocytes; to examine its effects on the oocyte developmental competence; to select oocytes based on the presence of the meiotic spindle detected by PLM; and to assess the efficiency oocyte enucleation assisted...

2011-01-01

359

Upper bound for a three-photon excitation cross section in atomic argon in the ultraviolet regime  

International Nuclear Information System (INIS)

A scheme of evaluating a generalized three-photon excitation cross section #sigma#/sub (3)/ in neutral atomic argon at 3144.67 A is outlined. Three photons at this wavelength can excite the neutral argon atoms from the ground 3p"6 "1S_0 state to the 3p"54s'[1/2]_1"0 state. The fourth photon will ionize the argon atoms. Assuming linear polarization of the incident laser radiation, contributions from several channels in various energy-level schemes are summed in the evaluation of the transition probability. For a laser linewidth of #DELTA##lambda#/sub L/ = 1 A, our maximum numerical value of the computed result for the three-photon excitation cross section is #sigma#/sub (3)/ = 1.414 x 10/sup -80/ cm"6 s"2. .AE.

8800-01-01

360

UV inactivation: Combined effects of UV radiation and xenobiotics in two strains of Saccharomyces  

International Nuclear Information System (INIS)

The effects of eight chemicals on the inactivation rate of ultraviolet radiation on the colony building capabilities of two strains of Saccharomyces cervisae - a wild type strain and a mutant deficient in excision repair - were studied. The insecticide methoxychlor, the herbicide 2,4-dichlorophenoxyacetic acid, the fungicide pentachlorophenol and its metabolite tetrachlorohydroquinone, as well as the chemicals acrylonitrile and 2,3-dichloro-1-propene have no significant impact on the effects of UV radiation in Saccharomyces cerevisae. Depending on the concentration, trichloroethylene increases the sensitivity to UV radiation. The herbicide paraquat provides efficient protection against UV radiation at concentrations where a toxic effect cannot be observed even without UV. The results were rather similar for both strains. (orig.).

361

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.

2004-02-28

362

Signatures of extra dimensions at e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.

2000-01-26

363

Schottky barrier modulation on silicon nanowires  

Science.gov (United States)

Oxide charge on the sidewalls of SiO{sub 2} embedded silicon wires with 20x20 nm{sup 2} cross section is shown to influence the Schottky barrier height for Pd{sub 2}Si/Si junctions positioned on the end surfaces of the wires. Compared with results on planar silicon surfaces, the electron barrier height is 0.3 eV lower for wires investigated as fabricated. By increasing the oxide charge through irradiation by ultraviolet light, the electron barrier decreases by an additional 0.15 eV and the hole barrier correspondingly increases by about the same amount. The phenomenon is explained by assuming an oxide charge density in the range of 10{sup 12} cm{sup -2}.

2007-03-26

364

Quadrant anode image sensor  

Science.gov (United States)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)

1976-11-01

365

Quadrant anode image sensor  

International Nuclear Information System (INIS)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.

9472-01-01

366

Positive effects of UV radiation on a calanoid copepod in a transparent lake: do competition, predation or food availability play a role?  

British Library Electronic Table of Contents (United Kingdom)

Zooplankton tolerant to ultraviolet radiation (UVR) could be indirectly affected by UVR through interactions with UV-sensitive species in the same ecosystem. In Lake Giles, Pennsylvania, USA, the calanoid copepod Leptodiaptomus minutus is more UVR tolerant than the cohabiting species Daphnia catawba and Cyclops scutifer. We asked whether L. minutus is affected by UV-induced mortality of a food competitor (D. catawba) or a predator of its nauplii (C. scutifer). We conducted two in situ enclosure experiments with six treatments: L. minutus alone, L . minutus + Daphnia and L. minutus + Cyclops in the presence and absence of UVR. There were few differences in survival among treatments in Experiment 1, which had enhanced food and a cumulative UVR (320 nm) dose of 9.3 kJ m-2. In Experiment 2, wh...

2006-01-01

367

Photosensitization by drugs. [Ultraviolet radiation  

Science.gov (United States)

uv irradiation (365 nm) of air-saturated methanol solutions of 20 drugs absorbing in the 300 to 400 nm region gave rise to oxygen uptake, as determined with a polarographic oxygen electrode. The drugs were tested for photosensitizing capability by either a Type I (free radical) or a Type II (single molecular oxygen) mechanism. This testing was done by the inclusion of either acrylamide or 2,5-dimethylfuran in the irradiated drug solution, with observation of the subsequent polymerization or oxidation, respectively. Phenothiazine and thiazide derivatives appear capable of photosensitization by both mechanisms; promethazine, trifluoperazine, and furosemide show relatively high reactivity. Diazepam (weak), hexachlorophene, aminacrine, pyrilamine, tetracycline, demeclocyline, quinine, and anthracene (strong) react only by a Type II mechanism, with a photosensitizing efficiency increasing in the order given. A correlation appears to exist with reports of in vivo photosensitivity.

1977-09-01

368

Photohemolytic potency of tetracyclines  

Energy Technology Data Exchange (ETDEWEB)

Hemolysis induced by long-wave ultraviolet radiation (UVA) and 8 different commercial tetracycline derivatives was studied in a model using human red blood cells. Demethylchlortetracycline and doxycycline were shown to have pronounced hemolytic properties causing 88% and 85% hemolysis, respectively, at a concentration of 50 micrograms/ml and 72 J/ cm2 of UVA. Tetracycline, oxytetracycline, and chlortetracycline caused maximally 18% hemolysis at 200 micrograms/ml and lymecycline only 7% at 100 micrograms/ml. Methacycline showed intermediate hemolytic effect of 36% at 200 micrograms/ml. Minocycline had no hemolytic effect whatsoever. These experimental data correlate very well with clinical reports and comparative phototoxicity trials in humans. Photohemolysis may thus be of value for predicting tetracycline phototoxicity.

1985-04-01

369

Mechanism of the accumulation effect in laser damage to polymers: appearance of microdamage due to an ionization absorption wave  

Energy Technology Data Exchange (ETDEWEB)

An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.

1984-04-01

370

Luminescence properties of Ca- and Yb-codoped SiAlON phosphors  

International Nuclear Information System (INIS)

Luminescence properties of SiAlON phosphors codoped with Ca and Yb were investigated by changing the host lattice composition. These modifications of the host lattice were obtained by replacing Si-N bonds by Al-N and Al-O bonds. Their photoluminescence (PL) and cathodoluminescence (CL) properties were measured and compared with each other. PL allows observing the influence of the host lattice modifications by measuring wider areas. CL can excite all luminescent centers, in particular the UV luminescence centers, even if their amount is small. Thus, two additional peaks in the ultraviolet and infrared regions were observed in CL, which is not observed by PL. This work suggests that the combination of PL and CL gives more understanding about the luminescence of SiAlON phosphors, in particular the role of the secondary phases on their properties.

2008-01-15

371

Low temperature deposition and characterization of TiO{sub 2} photocatalytic film through cold spray  

Energy Technology Data Exchange (ETDEWEB)

Cold spray was employed as a novel low temperature approach to deposit titanium dioxide (TiO{sub 2}) photocatalytic film. The film microstructure was characterized using X-ray diffraction and scanning electron microscopy. The photocatalytic performance was examined through acetaldehyde degradation under ultraviolet illumination. Results showed that TiO{sub 2} film was successfully deposited on substrate surface through cold spray. The film thickness reached up to 15 {mu}m. The film presented a rough surface and porous structure. Owing to the low temperature of spray powder, no phase and particle size changes occurred to TiO{sub 2} during deposition. It was found that the cold-sprayed TiO{sub 2} film was active for photodegradation of acetaldehyde.

2008-04-30

372

Kinetics of the methylparathion hydrolysis in aqueous medium; Cinetica de la hidrolisis del metilparation en medio acuoso  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of alkaline hydrolysis of methylparathion was studied at different temperatures (0-50 Centigrade) in the p H range of 8-12 by ultraviolet-visible absorption spectroscopy. Optimum p H and wavelength conditions were defined to carry out the simultaneous determination of methylparathion and one of its hydrolysis product, paranitrophenol, in buffered aqueous medium. Based on the experimental data and the mathematical equation of the kinetics, a rate constant (k) of first-order and an activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author) activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author)

1997-12-31

373

Investigating the Ultraviolet Properties of Gravity with a Wilsonian Renormalization Group Equation  

CERN Document Server

We review and extend in several directions recent results on the asymptotic safety approach to quantum gravity. The central issue in this approach is the search of a Fixed Point having suitable properties, and the tool that is used is a type of Wilsonian renormalization group equation. We begin by discussing various cutoff schemes, i.e. ways of implementing the Wilsonian cutoff procedure. We compare the beta functions of the gravitational couplings obtained with different schemes, studying first the contribution of matter fields and then the so-called Einstein-Hilbert truncation, where only the cosmological constant and Newton's constant are retained. In this context we make connection with old results, in particular we reproduce the results of the epsilon expansion and the perturbative one loop divergences. We then apply the Renormalization Group to higher derivative gravity. In the case of a general action quadratic in curvature we recover, within certain approximations, the known ...

2008-01-01

374

Intrinsic fluorescence of the amniotic fluid  

International Nuclear Information System (INIS)

The intrinsic fluorescence of clear amniotic fluid from third-trimester pregnancy is reported. The fluorescence intensity peaked at 405 nm when excited by ultraviolet light in the range of 310 to 360 nm. All of the 33 samples tested fluoresced, and their emission spectrum had the same shape, varying only in magnitude. Changing sample temperature (20 to 50 C) and sample pH (7.2 to 7.7) had little effect on the emission spectrum. The same fluorescence, with higher intensity, was observed when some newborn urine was tested. The fluorescence of amniotic fluid may provide a new tool to determine fetal age, fetal organ maturation, and fetal distress. (author).

1981-01-01

375

High power testing of a 17 GHz photocathode RF gun  

Energy Technology Data Exchange (ETDEWEB)

The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.

1996-12-31

376

Green synthesis of iron nanoparticles and their application as a Fenton-like catalyst for the degradation of aqueous cationic and anionic dyes  

British Library Electronic Table of Contents (United Kingdom)

Iron nanoparticles were produced using extracts of green tea leaves (GT-Fe NPs). The materials were characterized using TEM, SEM/EDX, XPS, XRD, and FTIR techniques and were shown to contain mainly iron oxide and iron oxohydroxide. The obtained nanoparticles were then utilized as a Fenton-like catalyst for decolorization of aqueous solutions containing methylene blue (MB) and methyl orange (MO) dyes. The related experiments investigated the removal kinetics and the effect of concentration for both MB and MO. The concentrations of dyes in aqueous solution were monitored using ultraviolet-visible (UV-vis) spectroscopy. The results indicated fast removal of the dyes with the kinetic data of MB following a second order removal rate, while those of MO were closer to a first order removal rate. T...

2011-01-01

377

Extended Conjugation in Polyaniline Like Structure Prepared by Plasma Polymerization Suitable for Optoelectronic Applications  

British Library Electronic Table of Contents (United Kingdom)

Plasma polymerization of aniline is carried out in a radiofrequency plasma reactor and the effect of polymerization time is examined in the structural, optical and optoelectronic properties of deposited films. Conjugated structures of polyaniline like films are obtained with unique and broad optical absorption band in the ultraviolet and entire visible region. The width of the absorption band increases and hence the optical band gap decreases with polymerization time. The optical constants are extracted by Swanepoel method and the optical dispersion parameters are determined by employing the Wemple-DiDomenico single oscillator model. The films exhibit similar thermal stability in air and argon atmosphere in the region of interest for optoelectronic applications. The photoluminescence study...

2011-01-01

378

Exploring the binding of the strong organic acceptor F{sub 4}TCNQ to coinage metals  

Energy Technology Data Exchange (ETDEWEB)

Organic/metal interface properties are of high interest for the application of molecular (sub)monolayers to modify surface properties. They are applied for, e.g., molecular electronics, chemical sensing, or the tuning of injection barriers in organic electronic devices. We present a joint theoretical and experimental study of F{sub 4}TCNQ adsorbed on Cu(111). The electronic and structural properties were determined by ultraviolet photoelectron spectroscopy (UPS) and X-ray standing wave (XSW) measurements. To better understand the complex process of binding, we modelled the system using density-functional theory. We find forward-donation from the lone pairs of the molecule into metallic states and back-donation from the metal into the LUMO of the molecule. The data on Cu(111) are compared to F4TCNQ on Au(111) and Ag(111) as well as to investigations of pyrenetetraone on various coinage metals.

2008-07-01

379

Determination of molar extinction coefficients #epsilon#_m(Ce"4"+) of Ce"4"+-Ce"3"+ dosimetric system  

International Nuclear Information System (INIS)

#epsilon#_m(Ce"4"+) values of the ceric-cereus system have been measured and the experimental procedure is described. Both routine titration method and electrochemical measurement were used. Some interference factors, such as ultraviolet, acidity and temperature, were studied as well. The temperature coefficient of #epsilon#_m(Ce"4"+) value in this experiment is about -0.1% degree C"-"1. A statistic analysis was made for 24 experimental values of #epsilon#_m(Ce"4"+) and a Gaussian distribution was found. Ultimately, an average molar extinction coefficient of 553.2 +- 1.3 m"2#centre dot#mol"-"1 was obtained at #approx#320 nm in 0.4 mol/L H_2SO_4 system, with a relative standard deviation of 0.24% (95% confidence level) and a total uncertainty of 1.5%.

1996-01-01

380

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

381

Construction and development of a UV free electron laser under the cooperation of Nihon U, KEK, PNC, ETL and Tohoku U  

Energy Technology Data Exchange (ETDEWEB)

The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.

1995-12-31

382

Conceptual design of industrial free electron laser using superconducting accelerator  

International Nuclear Information System (INIS)

Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.

1995-08-21

383

Clinical and experimental studies of octocrylene's allergenic potency  

British Library Electronic Table of Contents (United Kingdom)

Background. Reports of positive patch test and photopatch test reactions to the chemical ultraviolet filter octocrylene have increased during the last decade. Little is known about the reason for octocrylene's allergenic activity. Objectives. To present and discuss the results of patch tests and photopatch tests with octocrylene, and to investigate the possible cause of its allergenic properties. Methods. Results of patch tests and photopatch tests with octocrylene in patients with adverse skin reactions to sunscreen products and/or ketoprofen were collected. The allergenic potency of octocrylene was investigated in the murine local lymph node assay (LLNA). Chemical reactivity assays were used to mimic octocrylene's interaction with biomolecules. Results. We report 23 cases of positive tes...

2011-01-01

384

Chemical transformations of organic matter during the composting of wood industry wastes (residues); Transformacoes quimicas da materia organica durante a compostagem de residuos da industria madeireira  

Energy Technology Data Exchange (ETDEWEB)

Composting of sawdust and paper mill sludge, using a 'Kneer' process reactor, was studied in an attempt to elaborate upon organic matter transformation during the process and to define parameters to measure the compost maturity level. Temperature, electron paramagnetic resonance data, ash and C, H, N and S contents, and a spectroscopic method using ultraviolet-visible (UV-VIS) for alkaline (pH = 8.5) and solid samples was used to study the maturity of the compost samples. These parameters were measured in 6 humic acids extracted from the compost samples during 29 days. The results of this work show that the 'Kneer' process is efficient in transforming ligno-celulitic residues in a short time (29 days), into an organic fertilizer material with application perspectives (author)

2004-06-01

385

Broad-linewidth laser absorption measurements of oxygen between 211 and 235nm at high temperatures  

British Library Electronic Table of Contents (United Kingdom)

Absorption coefficient data are presented for molecular oxygen at temperatures between 1100 and 2000K and discrete wavelengths between 211 and 235nm. Measurements were made behind reflected shock waves using broad-linewidth ultraviolet laser radiation generated from a frequency-quadrupled, tunable, pulsed Ti:Sapphire laser. Test mixtures consisting of 15% O"2, 15% He and balance Ar were used to minimize the influence of vibrational relaxation on the reflected shock temperature. The experimental results are in good agreement with theoretical calculations and confirm that discrete features from the Schumann-Runge system dominate between 211 and 235nm at temperatures higher than 1100K.

2011-01-01

386

Bonding and microstructural stability in Ni55Ti45 studied by experimental and theoretical methods  

Energy Technology Data Exchange (ETDEWEB)

Spiral orbit tribometry friction tests performed on Ni-rich Ni55Ti45 titanium ball bearings indicate that this alloy is a promising candidate for future aerospace bearing applications. Microstructural characterization of the bearing specimens was performed using transmission electron microscopy and energy dispersive spectroscopy, with NiTi, Ni4Ti3, Ni3Ti, and Ni2Ti4Ox phases identified within the microstructure of the alloy. Density functional theory was applied to predict the electronic structure of the NixTiy phases, including the band structure and site projected density of states. Ultraviolet photoemission spectroscopy was used to verify the density of states results from the density functional theory calculations, with good agreement observed between experiment and theory.

2010-11-25

387

Asphalt emulsion sealing of uranium mill tailings. 1980 annual report  

International Nuclear Information System (INIS)

Studies of asphalt emulsion sealants conducted by the Pacific Northwest Laboratory have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to near background levels. Field tests at the tailings pile in Grand Junction, Colorado, confirmed that an 8-cm admix seal containing 22 wt% asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and compacted, overburden was applied over the seal to protect the seal from ultraviolet degradation.

388

Application of asphalt emulsion seals to uranium mill tailings  

International Nuclear Information System (INIS)

Studies of asphalt emulsion sealants have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to less than background levels. Field tests at the tailings pile in Grand Junction, Colorado confirmed that an 8-cm admix seal containing 22 wt % asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and conpacted, overburden was applied over the seal to protect the seal from ultraviolet degradation. 14 figures.

389

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability between the metal mold and the compact. (author)

1999-01-15

390

Amperometric biosensor for hydrogen peroxide based on horseradish peroxidase onto gold nanowires and TiO2 nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

An electrochemical biosensor for determination of hydrogen peroxide (H2O2) was fabricated, based on the electrostatic immobilization of horseradish peroxidase (HRP) with one-dimensional gold nanowires (Au NWs) and TiO2 nanoparticles (nano-TiO2) on a gold electrode. The nano-TiO2 can give a biocompatible microenvironment and compact film, and the Au NWs can provide fast electron transferring rate and greatly add the amount of HRP molecules immobilized on the electrode surface. Au NWs were characterized by ultraviolet?visible spectra and transmission electron microscope. The electrode modification process was probed by cyclic voltammetry and electrochemical impedance spectroscopy. Chronoamperometry was used to study the electrochemical performance of the resulting biosensor. Under optimal co...

2011-01-01

391

AlxGa1-xN/GaN multi-quantum-well ultraviolet detector based on p-i-n heterostructures  

British Library Electronic Table of Contents (United Kingdom)

We report on characterization of a set of AlGaN/GaN multiple-quantum-well (MQW) photodetectors. The model structure used in the calculation is the p-i-n heterojunction with 20 AlGaN/GaN MQW structures in i-region. The MQW structures have 2nm GaN quantum well width and 15nm AlxGa1-xN barrier width. The cutoff wavelength of the MQW photodetectors can be tuned by adjusting the well width and barrier height. Including the polarization field effects, on increasing Al mole fraction, the transition energy decreases, the total noise increases, and the responsivity has a red shift, and so the detectivity decreases and has a red shift.

2009-01-01

392

Advanced oxidation process based on ozone/electron beam irradiation for treating groundwater  

International Nuclear Information System (INIS)

There are several methods of generating OH free radicals from ozone and/or hydrogen peroxide and ultraviolet light. They all have in common that the OH free radicals originate in one single source only whereas in the combination of ozone with ionizing radiation two simultaneous working sources for the OH free radicals exist. The resulting higher OH free radical concentration makes this process especially apt for the remediation of low level contaminated groundwater as for example trichloroethylene (TCE) contamination in the sub-ppm range. A cost comparison between O_3/UV and O_3/electron beam for remediation of a groundwater contaminated with 100 ppb TCE indicated that for a throughput of about 5 million gallons/day the O_3/electron beam process is more cost-effective. (authors).

393

State of the Art Laser Induced Breakdown Spectroscopy  

International Nuclear Information System (INIS)

Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on the environmental ...

394

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...

2009-12-01

395

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of individual fission ...

1997-05-01

396

Vacuum energy of eleven-dimensional supergravity  

Energy Technology Data Exchange (ETDEWEB)

The authors calculate the effective potential for the bosonic sector of eleven-dimensional supergravity on the background (Minkowski) x (sphere). No tachyons are found, and it is shown that the antisymmetric tensor field does not threaten graviton dominance when the Freund-Rubin parameter (m) vanishes. The general case (m not = O) seems untractable in the present formalism.

1987-11-01

397

Ultra high vacuum test setup for electron gun  

Energy Technology Data Exchange (ETDEWEB)

Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and ...

2008-05-01

398

Transition of rotating Bianchi type-IX cosmological model into an inflationary era  

Energy Technology Data Exchange (ETDEWEB)

A Bianchi type-IX cosmological model has been found as a solution of Einstien's vacuum field equations with a cosmological constant. The solution represents a rotating generalziation fo the de Sitter universe. This universe shows a transition to exponential expansion and the vorticity begins to decay exponentially at the grand-unified-theory time. The point of time for this transition is independent of the magnitude of the vorticity. During the Guth inflationary era the vorticity decays by a factor of the order 10 US.

1986-02-15

399

Transition of rotating Bianchi type-IX cosmological model into an inflationary era  

International Nuclear Information System (INIS)

A Bianchi type-IX cosmological model has been found as a solution of Einstien's vacuum field equations with a cosmological constant. The solution represents a rotating generalziation fo the de Sitter universe. This universe shows a transition to exponential expansion and the vorticity begins to decay exponentially at the grand-unified-theory time. The point of time for this transition is independent of the magnitude of the vorticity. During the Guth inflationary era the vorticity decays by a factor of the order 10"-"1"4"2.

400

The physics of tachyons. Pt. 2  

International Nuclear Information System (INIS)

This paper extends the development of a new formulation of the theory of tachyons to encompass the dynamics of tachyons. Energy and momentum are discussed along with the proper mass of a tachyon. The transformation of force in extended relativity (ER) is derived. Acceleration in ER is also discussed, as well as the relationship between force and acceleration. Two simple examples relating to the motion of a charged tachyon are discussed, followed by a brief explanation of why tachyons cannot emit Cerenkov radiation in a vacuum. 13 refs., 3 figs.

401

Tachyons: may they have a role in elementary particle physics  

International Nuclear Information System (INIS)

The possible role of space-like objects in elementary particle physics (and in quantum mechanics) is reviewed and discussed, mainly by exploiting the explicit consequences of the peculiar relativistic mechanics of Tachyons. Particular attention is paid: (i) to tachyons as the possible carriers of interactions; (ii) to the possibility of ''vacuum decays'' at the classical level; (iii) to a Lorentz-invariant bootstrap model; (iv) to the apparent shape of the tachyonic elementary particles and its possible connection with the de Broglie wave-particle dualism. (author).

402

Tachyons and the radiation of an accelerated charge  

Energy Technology Data Exchange (ETDEWEB)

The motion of an accelerated charge in a vacuum is analyzed, via the superposition principle and Fourier analysis, into uniform-motion components, which include bradyonic as well as tachyonic contributions. It is shown that the former contribute only to the induction fields whereas the latter are the source of the radiation emitted by the charge, via the Sommerfeld-Cerenkov mechanism. This result calls for a reexamination of some recently formulated theories of superluminal particles.

1982-10-15

403

Review of ion-based coating processes derived from the cathodic arc  

International Nuclear Information System (INIS)

The cathodic vacuum arc provides a means of producing large currents of positive ions of a wide variety of materials. These ions can be utilized to produce coatings with improved properties such as higher density and adhesion. The processing is particularly useful in reactive deposition of ceramic coatings having excellent stoichiometry. In this review, emerging aspects of the technology are emphasized.

404

Quantum chaos in the mixmaster universe  

Energy Technology Data Exchange (ETDEWEB)

A Monte Carlo simulation of the vacuum Bianchi type-IX (mixmaster) cosmology yields a significant correlation between large universe volume and high anisotropy. An analog of the model's chaotic classical behavior is seen in the break up of the universe wave function at large volume into fingers in the corners of the minisuperspace anisotropy potential.

1989-04-15

405

Preparation of Cluster States for Many Atoms in Cavity QED  

International Nuclear Information System (INIS)

We propose a scheme for the generation of the cluster states for many atoms in cavity QED. In our scheme, the atoms are sent through nonresonant cavity fields in the vacuum states. The cavity fields are only virtually excited and no quantum information will be transferred from the atoms to the cavity fields. The advantage is that the cavities are suppressed during the procedure. The scheme can also be generalized to the ion trap system.

2007-07-15

406

Photodetachment of negative ion beams in the presence of a background gas  

Energy Technology Data Exchange (ETDEWEB)

To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.

1987-03-01

407

Optical measurement of electron bunching in vacuum  

International Nuclear Information System (INIS)

We report the homodyne detection of phase modulation sidebands induced on a laser beam by a coherently bunched electron beam. This provides a sensitive and nonperturbing measurement of complex Fourier time series components of the electron density. A proof-of-principle measurement of the microwave frequency component of electron density in a crossed-field device, which agrees well with a calculation of the same quantity, is reported.

408

On condensation of closed-string tachyons  

Energy Technology Data Exchange (ETDEWEB)

An F-theory dual of a non-supersymmetric orientifold is considered. It is argued that the condensation of both open and closed string tachyons in the orientifold corresponds to the annihilation of branes and antibranes in the F-theory dual. One likely end-point of tachyon condensation is thus expected to be the vacuum of Type-IIB superstring. Some speculations are presented about the F-theory dual of the bosonic string and tachyon condensation thereof.

2002-09-09

409

Nonformity of the electron density in amorphous silicon films  

Energy Technology Data Exchange (ETDEWEB)

The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.

1985-12-01

410

New development of external-PIXE system using a differential pumping technique  

International Nuclear Information System (INIS)

A new external-PIXE system utilizing a differential pumping technique, which can completely protect the accelerator and vacuum pumps when the exit foil breaks down, has been developed. Applications to analyses of liquid and heavily-outgassing samples were successfully achieved. Also, experiments for evaluating the efficiency of the system were performed and results will be presented. (author)

1999-09-01

411

Multidimensional extension of the Bianchi type-IX cosmology  

Energy Technology Data Exchange (ETDEWEB)

A higher-dimensional homogeneous spacetime is investigated satisfying the vacuum Einstein equations. It is assumed that the algebra of Killing vectors L admits a non-trivial Levi decomposition L=N+so(3), i.e. that the subalgebras N and so(3) do not commute. It is found that the model behaves in a non-chaotic way and cosmological dimensional reduction inevitably occurs. This model completes all the possible types within the class of higher-dimensional extensions of Bianchi type-IX cosmology.

1988-06-09

412

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

413

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

414

In situ air stripping using horizontal wells. Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

In-situ air stripping employs horizontal wells to inject or sparge air into the ground water and vacuum extract VOC`S from vadose zone soils. The horizontal wells provide better access to the subsurface contamination, and the air sparging eliminates the need for surface ground water treatment systems and treats the subsurface in-situ. A full-scale demonstration was conducted at the Savannah River Plant in an area polluted with trichloroethylene and tetrachloroethylene. Results are described.

1995-04-01

415

Heavy and light quarks in the instanton vacuum  

CERN Document Server

Assuming the gluon field is well approximated by instanton configurations we derive a light quarks determinant and calculate its contribution to the specific heavy quarks correlators -- namely, the heavy quark propagator and heavy quark-aniquark correlator, receiving the instanton generated light-heavy quarks interaction terms contributions. With these knowledge we calculate the light quark contribution to the interaction between heavy quarks, which might be essential for the properties of a few heavy quarks systems.

2011-01-01

416

Emittance of investment casting molds  

Energy Technology Data Exchange (ETDEWEB)

This document describes measurements of the directional spectral emittance of four ceramic mold materials. The work was performed with the samples at {approximately} 900{degree}C in a vacuum vessel pumped to {approximately}3 {times} 10{sup {minus}6}Torr. Results conform to expectations derived from prior work done with similar samples.

1994-07-15

417

Design and fabrication of a traveling-wave muffin-tin accelerating structure at 90 GHz  

Energy Technology Data Exchange (ETDEWEB)

A prototype of a muffin-tin accelerating structure operating at 32 times the SLAC frequency (2.856 GHz) was built for research in high gradient acceleration. A traveling-wave design with single input and output feeds was chosen for the prototype which was fabricated by wire electrodischarge machining. Features of the mechanical design for the prototype are described. Design improvements are presented including considerations of cooling and vacuum.

1997-05-01

418

DC CHARACTERIZATION OF HIGH GRADIENT MULTILAYER INSULATORS  

Energy Technology Data Exchange (ETDEWEB)

We have developed a novel insulator concept that involves the use of alternating layers of conductors and insulators with periods less than 1 mm. We have demonstrated that these structures perform 2 to 5 times better than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present new testing results showing exceptional behavior at DC, with gradients in excess of 110kV/cm in vacuum.

2005-05-26

419

Canonical Gravity with Fermions  

CERN Document Server

Canonical gravity in real Ashtekar-Barbero variables is generalized to allow for fermionic matter. The resulting torsion changes several expressions in Holst's original vacuum analysis, which are explicitly displayed here. This in turn requires adaptations to the known canonical (loop) quantization of gravity coupled to fermions, which is discussed on the basis of the classical analysis.

2007-01-01

420

A multidimensional extension of the Bianchi type-IX cosmology  

International Nuclear Information System (INIS)

A higher-dimensional homogeneous spacetime is investigated satisfying the vacuum Einstein equations. It is assumed that the algebra of Killing vectors L admits a non-trivial Levi decomposition L=N+so(3), i.e. that the subalgebras N and so(3) do not commute. It is found that the model behaves in a non-chaotic way and cosmological dimensional reduction inevitably occurs. This model completes all the possible types within the class of higher-dimensional extensions of Bianchi type-IX cosmology. (orig.).

421

A magneto-electric quantum wheel  

CERN Document Server

Here we show that self-propulsion in quantum vacuum may be achieved by rotating or aggregating magneto-electric nano-particles. The back-action follows from changes in momentum of electro-magnetic zero-point fluctuations, generated in magneto-electric materials. This effect may provide new tools for investigation of the quantum nature of our world. It might also serve in the future as a "quantum wheel" to correct satellite orientation in space.

2009-01-01

422

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-15

423

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-01

424

Some relationships between ultraviolet light and heme-protein-induced peroxidative lipid breakdown in liposomes, as reflected by fluorescence changes: the effect of negative surface charge  

International Nuclear Information System (INIS)

The water soluble, photolabile nitrene precursor, azidonaphthalene-2,7-disulfonic acid (ANDS) was encapsulated in small unilamellar, isoelectric (egg PC) or negatively charged (egg PC + dihexadecylphosphate) liposomes. The individual and combined effects of heme-proteins and UV irradiation on the fluorescence of these vesicles under aerobic conditions were studied. Consistent with the catalytic action of heme-proteins on lipid peroxidation and peroxide decomposition, addition of cytochrome c (positively charged) or catalase (negatively charged) to the vesicles elicited immediate formation of a fluorescence band at 470 nm, characteristic of Schiff bases that form from aldehyde byproducts of decomposing hydroperoxides. Ultraviolet irradiation of liposomes caused no significant changes in the fluorescence spectrum, in spite of the radiolysis of ANDS inside the vesicles with consequent formation of nitrene radicals. When isoelectric vesicles were irradiated with UV ...

425

Physical, biochemical and physiological effects of ultraviolet radiation on Brassica napus and Phaseolus vulgaris  

International Nuclear Information System (INIS)

In order to follow some of the changes induced by ultraviolet-B (UV-B, 280-320 nm) radiation in Phaseolus vulgaris and Brassica napus, experiments were designed to localize sites of changes in leaves and to correlate some of the physiological and biochemical changes with penetration of UV-B radiation. B.napus was exposed to 8.9 kJ m"-"2 day"-"1 biologically effective UV-B radiation (UV-B_B_E). The penetration of UV-B radiation into the leaf was followed using a quartz fibre optic microprobe. Monochromatic radiation at 310 nm was decreased by ca 50 and 34% in the adaxial and abaxial epidermis, respectively, in plants not exposed to UV-B, whereas the radiation was decreased by ca 70 and 42%, respectively, in the same region in UV-treated plants. Polychromatic radiation showed a wavelength dependent change mainly for the collimated radiation. The results correlated with the distribution of phenolic compounds analysed from 40 #mu#m paradermal leaf sections. The first ...

1991-11-05

426

Photoresponsivity of ultraviolet detectors based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloys  

Energy Technology Data Exchange (ETDEWEB)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with GaN. The ...

2000-08-07

427

Photoresponsivity of ultraviolet detectors based on In_xAl_yGa_1_-_x_-_yN quaternary alloys  

International Nuclear Information System (INIS)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with GaN. The advantages of In_xAl_yGa_1_-_x_-_yN quaternary over ...

2000-08-07

428

Organ culture of mammalian skin and the effects of ultraviolet light and testosterone on melanocyte morphology and function  

Science.gov (United States)

Scrotal skin of black Long-Evans rats and human thigh skin were maintained in vitro as organ cultures for as long as 14 days, and examined histologically using the combined skin splitting and Dopa techniques. Selected rat skin cultures received testosterone in the culture medium and/or were irradiated with ultraviolet light (290 to 320 nm uvl). With increased time in culture, scrotal melanocytes round up and there is an increase in epidermal pigmentation. Human skin behaves similarly; after eight days in vitro human melanocytes also become rounded, but remain strongly Dopa-positive. Addition of exogenous testosterone to cultured rat skin maintains dendritic morphology of melanocytes, but cell body size is still reduced. uvl irradiation stimulates melanocytes in rat skin cultures, maintaining their dendritic morphology and increasing epidermal and dermal pigmentation. Cultured skin receiving both uvl and testosterone illustrates a synergistic effect. Electron ...

1978-05-01

429

Measurement of the population densities in Gd atomic vapor using diode laser absorption spectroscopy in UV transitions  

International Nuclear Information System (INIS)

We report on the ultraviolet laser absorption spectroscopy of atomic Gd at 394-554 nm where two transition lines are place very closely by using a frequency-doubled beam of external-cavity diode laser (ECDL). One is from 999.121 to 26337.071 cm-1 and the other from 0 to 25337.755 cm-1. If two transition lines are placed closely within a continuous fine tuning range, the real-time measurement of the atomic excitation temperature is possible without any significant time consumption because at least two transition lines originating from different low-lying energy levels need to be investigated for the Boltzmann-plot. Since the spectral difference between the two transitions is only about 0.195 cm-1 (5.85 GHz), it is possible to record both the absorption spectra simultaneously as shown in Fig. 1. But the transition probabilities (or oscillator strengths) of these lines have not been measured accurately yet to the best of our knowledge. We report on the newly measured ...

2003-11-07

430

Laser-assisted solar cell metallization processing. Quarterly report, September 13-December 12, 1983  

Energy Technology Data Exchange (ETDEWEB)

The Westinghouse Electric Corporation has undertaken to investigate, develop, and characterize laser-assisted processing techniques utilized to produce the fine line, thin metal grid structures that are required to fabricate high-efficiency solar cells. Two basic techniques for metal deposition will be investigated, as follows: (1) photochemical decomposition of liquid or gas phase organometallic compounds utilizing either a focused, CW ultraviolet laser (System 1) or a mask and ultraviolet flood illumination, such as that provided by a repetitively pulsed, defocused excimer laser (System 2), for pattern definition, and (2) thermal deposition of metals from organometallic solutions or vapors utilizing a focused, CW laser beam as a local heat source to draw the metallization pattern. The purpose of this contract is to investigate the various existing laser-assisted film deposition techniques in order to develop a new, cost-effective technology ...

1984-01-16

431

Growth-related variations in the glycosaminoglycan synthesis of ultraviolet light-induced murine cutaneous fibrosarcoma cells  

Energy Technology Data Exchange (ETDEWEB)

Glycosaminoglycan synthesis was studied in cell populations of ultraviolet light-induced murine cutaneous fibrosarcoma cells under conditions of varying growth rates in vitro. After labeling with the precursors, /sup 3/H-glucosamine and /sup 35/SO/sub 4/, sulfated glycosaminoglycans recoverable by direct proteolysis of the culture monolayers increased approximately 5-fold on a per cell basis from sparsely populated, exponential cell cultures (greater than 85% of cells in S, G2, or M phases) to stationary cultures inhibited by high cell density (greater than 50% of cells in G1). Within this cell surface-associated material, the relative ratio of heparan sulfate to the chondroitin sulfates was approximately 60/40% under conditions of exponential growth; in the growth-arrested cultures, the reverse ratio was found. The substratum attached material, obtained from the flask surface after ethyl glycol bis(beta-aminoethyl ether)-N,N'-tetraacetic acid ...

1985-08-01

432

An in vitro model to test relative antioxidant potential: Ultraviolet-induced lipid peroxidation in liposomes  

International Nuclear Information System (INIS)

Since antioxidants have been shown to play a major role in preventing some of the effects of aging and photoaging in skin, it is important to study this phenomenon in a controlled manner. This was accomplished by developing a simple and reliable in vitro technique to assay antioxidant efficacy. Inhibition of peroxidation by antioxidants was used as a measure of relative antioxidant potential. Liposomes, high in polyunsaturated fatty acids (PUFA), were dispersed in buffer and irradiated with ultraviolet (UV) light. Irradiated liposomes exhibited a significantly higher amount of hydroperoxides than liposomes containing antioxidants in a dose- and concentration-dependent manner. Lipid peroxidation was determined spectrophotometrically by an increase in thiobarbituric acid reacting substances. To further substantiate the production of lipid peroxides, gas chromatography was used to measure a decrease in PUFA substrate. In order of decreasing antioxidant effectiveness, ...

433

[Electronic and structural properties of individual nanometer-size supported metallic clusters]. Progress report  

Energy Technology Data Exchange (ETDEWEB)

The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their ...

1991-11-01

434

Why there is a field algebra with a compact gauge group describing the superselection structure in particle physics  

International Nuclear Information System (INIS)

Given the local observables in the vacuum sector fulfilling a few basic principles of local quantum theory, we show that the superselection structure, intrinsically determined a priori, can always be described by a unique compact global gauge group acting on a field algebra generated by field operators which commute or anticommute at spacelike separations. The field algebra and the gauge group are constructed simultaneously from the local observables. There will be sectors obeying parastatistics, and intrinsic notion derived from the observables, if and only if the gauge group is non-Abelian. Topological charges would manifest themselves in field operators associated with spacelike cones but not localizable in bounded regions of Minkowski space. No assumption on the particle spectrum or even on the covariance of the theory is made. However the notion of superselection sector is tailored to theories without massless particles. When translation or Poincare covariance ...

1990-01-01

435

Water uptake and exchange kinetics of polyelectrolyte films: a neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The sequential layer-by-layer adsorption of polyanions and polycations to build polyelectrolyte multilayers has triggered enormous interest in their potential uses in a wide range of fields, from photonic to pharmaceutical applications. We show that the conformation of the solvent swollen films - prior to drying - is determined by the initial adsorption conditions, but can be altered ex-situ by exposure to a liquid phase of very high ionic strength. Recently it has been observed that the swelling depends on the charge of the outermost layer. In the PAH/PSS system we saw that assemblies with PSS as the outermost layer swell more than those with PAH outside. A neutron reflectivity study of this effect in addition indicated the existence of two kinds of water, bound with different strength within the films. Beside an unexpected two-step kinetics of swelling, the reflectivity curves of the layers against vacuum before and after re-hydration in D{sub 2}O vapor did not ...

2007-07-01

436

The role of Computerized Tomography in osteoid-osteoma diagnosis  

International Nuclear Information System (INIS)

Alcaptonuria is a rare autosomal recessive metabolic disease, due to the lack of homogentisic acid oxidase. The following accumulation of homogentisic acid brings about a black discoloration of both the urine alcaptonuria) and connective tissue (ochronosis). The ochronotic alterations into joint cartilages cause degenerative arthropathy and osteopenia. The radiological features of three unrelated cases of alcaptonuria are reported. Radiographic abnormalities of ochconotic arthropathy are found in both the spine and the extraspinal joints. In the spine, the progressive calcification and ''vacuum'' phenomenon of disc spaces are the most characteristic findings. Disc space narrowing is associated with calcification and marginal sclerosis of vertebral bodies and is accentuated by osteopenia. Osteophytes are usually absent or of small size; neverthless progressive formation of marginal intervertebral bridges and obliteration of disc spaces at multiple levels ...

1988-01-01

437

Superconducting A-15 Nb_3Ge films produced by reactive evaporation  

International Nuclear Information System (INIS)

The reactive evaporation process was successfully used to deposit films of the A-15 Nb_3Ge phase. This is the first report, to the best of our knowledge, illustrating the use of such processes for the deposition of A-15 compounds. In this process, niobium vapors from an electron-beam-heated evaporation source react with germane gas introduced into the vacuum chamber at low partial pressures (approximately 10"-"4 Torr) to produce Nb_3Ge deposits. The process variables studied were the deposition temperature, the niobium-to-germanium impingement ratio on the substrate and the plasma-enhanced deposition, in this case the activated reactive evaporation process. At low deposition temperatures (below 450"0C) the deposit is amorphous (or microcrystalline) and can be crystallized to the Nb_3Ge phase by heat treatment, e.g. at 850"0C for 1 h in vacuum. The ratio of niobium to germanium in the deposit can be varied by changing the process parameters. The ...

438

Remodeling of the free electron laser with the L-band linac at Osaka University  

International Nuclear Information System (INIS)

The far infrared free electron laser (FEL) has been being developed since 1990 using the L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. The first lasing was obtained in 1994 at wavelengths from 32 to 40 #mu#m. The FEL is now being modified suitable for user experiments. The wiggler with a fixed magnet gap used in the original FEL has been remodeled to make the magnet gap variable. In order to optimize the variable range of the gap, the gain and the diffraction loss were calculated. The peak gain is calculated to be 270% and the diffraction loss to be 22% at 150 #mu#m. The wavelength is expected to be variable from 25 up to at least 150 #mu#m. The two bending magnets in the optical resonator have been remodeled and the vacuum chambers with larger vertical sizes for them have been newly made so that the diffraction loss in these parts becomes smaller than that in the vacuum chamber of the wiggler. ...

1997-02-28

439

Parametric study of radiative cooling of solid antihydrogen. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and hydrogen's ...

1989-03-01

440

On Geometrical Interpretation of Non-Abelian Flat Direction Constraints  

CERN Document Server

In order to produce a low energy effective field theory from a string model, it is necessary to specify a vacuum state. In order that this vacuum be supersymmetric, it is well known that all field expectation values must be along so-called flat directions, leaving the F- and D-terms of the scalar potential to be zero. The situation becomes particularly interesting when one attempts to realize such directions while assigning VEVS to fields transforming under non-Abelian representations of the gauge group. Since the expectation value is now shared among multiple components of a field, satisfaction of flatness becomes an inherently geometrical problem in the group space. Furthermore, the possibility emerges that a single seemingly dangerous F-term might experience a self-cancellation among its components. The hope exists that the geometric language can provide an intuitive and immediate recognition of when the D and F conditions are simultaneously ...

2005-01-01

441

Kapitza conductance of the (100) surface of copper  

International Nuclear Information System (INIS)

Measurements of the Kapitza conductance to liquid helium II across the (100) surface of single crystals of copper are presented. The temperature range of these measurements was 1.6-- 2.1 K. The sample surfaces were subjected to several different treatments. Some surfaces were cleaned by low-energy argon ion bombardment, annealed in an ultrahigh-vacuum system, and preserved under vacuum until purified liquid helium was admitted. Other surfaces were intentionally damaged by machining and/or exposure to the atmosphere. The conductance after these latter treatments was found to be about a factor of three higher than that of the more ideally cleaned and annealed surfaces, and a significant difference in the temperature dependence of the conductance was also observed. Conductances were reproducible for similarly treated surfaces and correlated with surface damage determined by x-ray diffraction. The relationship of these results to the numerous ...

442

Influence of the substrate coating temperature on the vacuum properties of Ti-Zr-V non-evaporable getter films  

CERN Document Server

Non-evaporable thin film getters of various compositions have been produced by sputtering. Among about 20 materials which have been studied, the lowest activation temperature (about 180 degree C) has been displayed by a Ti-Zr-V coating obtained from a cathode made of intertwisted elemental wires. In order to optimize the vacuum properties of this film various production parameters, including the substrate temperature during coating, have been varied. The films have been characterized by pumping speed measurement, secondary electron microscopy, and X-ray diffraction. It has been found that the substrate coating temperature affects significantly the activation temperature, the pumping speed and the gas surface capacity. The highest pumping speed values, obtained for substrate coating temperatures of 250 degree C and 300 degree C, are clearly correlated with the increased surface roughness and porosity of the Ti-Zr-V film.

2003-01-01

443

In situ ultrahigh vacuum transmission electron microscopy studies of palladium silicide island formation on silicon (111) 7x7 surface  

Energy Technology Data Exchange (ETDEWEB)

Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.

2003-01-22

444

Holomorphic wave function of the Universe  

Energy Technology Data Exchange (ETDEWEB)

The quantum behavior of the vacuum Bianchi type-IX universe with the cosmological constant is investigated in terms of the Ashtekar variables. An exact solution to the quantum Hamiltonian constraint in the holomorphic representation is given. This solution reduces to the Hartle-Hawking wave function in the spatially isotropic sector and extends in the triad representation to the classically forbidden region where the determinant of the spatial metric becomes negative. The analysis of the quantum Robertson-Walker universe indicates that if the superspace is extended to such a classically forbidden region, the holomorphic representation picks up some restricted class of solutions in general. This observation leads to a new ansatz on the boundary condition of the Universe. In particular, the behavior of the Lorentzian and Euclidean WKB orbits corresponding to the solution suggests a new picture on the semiclassical behavior of the quantum Universe: that the Universe ...

1990-10-15

445

Holomorphic wave function of the Universe  

International Nuclear Information System (INIS)

The quantum behavior of the vacuum Bianchi type-IX universe with the cosmological constant is investigated in terms of the Ashtekar variables. An exact solution to the quantum Hamiltonian constraint in the holomorphic representation is given. This solution reduces to the Hartle-Hawking wave function in the spatially isotropic sector and extends in the triad representation to the classically forbidden region where the determinant of the spatial metric becomes negative. The analysis of the quantum Robertson-Walker universe indicates that if the superspace is extended to such a classically forbidden region, the holomorphic representation picks up some restricted class of solutions in general. This observation leads to a new ansatz on the boundary condition of the Universe. In particular, the behavior of the Lorentzian and Euclidean WKB orbits corresponding to the solution suggests a new picture on the semiclassical behavior of the quantum Universe: that the Universe ...

446

Hard, infrared black coating with very low outgassing  

Energy Technology Data Exchange (ETDEWEB)

Infrared astronomical instruments require absorptive coatings on internal surfaces to trap scattered and stray photons. This is typically accomplished with any one of a number of black paints. Although inexpensive and simple to apply, paint has several disadvantages. Painted surfaces can be fragile, prone to shedding particles, and difficult to clean. Most importantly, the vacuum performance is poor. Recently a plasma enhanced chemical vapor deposition (PECVD) process was developed to apply thick (30 {micro}m) diamond-like carbon (DLC) based protective coatings to the interior of oil pipelines. These DLC coatings show much promise as an infrared black for an ultra high vacuum environment. The coatings are very robust with excellent cryogenic adhesion. Their total infrared reflectivity of < 10% at normal incidence approaches that of black paints. We measured outgas rates of <10{sup -12} Torr liter/sec cm{sup 2}, comparable to bare ...

2008-06-02

447

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m ...

2003-06-01

448

Focused ion-beam line profiles: A study of some factors affecting beam broadening  

Energy Technology Data Exchange (ETDEWEB)

The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ``wings`` that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least for the lighter ions ...

1995-11-01

449

Focused ion-beam line profiles: A study of some factors affecting beam broadening  

International Nuclear Information System (INIS)

The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ''wings'' that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least for the lighter ions ...

450

First plasma experiment on spherical tokamak device UTST  

International Nuclear Information System (INIS)

The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasma obtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma obtained 10 kA by using only outer PF coils and single ST was generated at the lower area (z=-0.3 - -1.0[m]) close to a washer gun. This result suggests that another ...

2009-04-01

451

Composites in the TiC-TiYTZP system  

International Nuclear Information System (INIS)

Ceramic matrix composites in the TiC-Ti, Y-TZP system can be synthesized by the reaction between carbon and the TiO_2-Y_2O_3-ZrO_2 solid solution nanopowder. This method results in the more homogeneous powders than those prepared by the physical mixing of TiC and zirconia s.s. powders. Twelve TiO_2-Y_2O_3-ZrO_2 solid solution nanopowders differing in the proportions of the constituent oxides were prepared by the coprecipitation- calcination route. They were reacted with the pyrolytic carbon evenly distributed within the system. Carbon was introduced by the thermal decomposition of the phenol-formaldehyde resin dissolved in ethyl alcohol and mixed with the zirconia s.s. nanopowder. Reaction was performed in vacuum. Compacts of the composite powders sintered in vacuum give dense materials of evenly distributed TiC inclusions of sizes not surpassing 400 nm. Hardness of such materials was dependent on their chemical and phase composition but was ...

2003-09-25

452

Biaxial Bianchi type IX quantum cosmology  

Energy Technology Data Exchange (ETDEWEB)

We investigate the quantum cosmology of spatially homogeneous models with compact spatial sections admitting a u(2) isometry algebra. The metric ansatz in these models is that of Bianchi type IX with two scale factors set to be equal. We apply the Hartle-Hawking no-boundary path integral prescription and find the semi-classical contributions to the wave function. Exact formulae are obtainable for certain contributions and otherwise the limits of large and small anisotropy (for the pure vacuum case) and large spatial volume or small anisotropy (for the case with a positive cosmological constant) are considered. For the pure vacuum case we find no rapidly oscillating semiclassical components in the wave function, and hence do not recover lorentzian space-time as a prediction of the no-boundary proposal. For the case with a cosmological constant the wave function does contain rapidly oscillating components and thus predicts approximately ...

1991-03-11

453

Biaxial Bianchi type IX quantum cosmology  

International Nuclear Information System (INIS)

We investigate the quantum cosmology of spatially homogeneous models with compact spatial sections admitting a u(2) isometry algebra. The metric ansatz in these models is that of Bianchi type IX with two scale factors set to be equal. We apply the Hartle-Hawking no-boundary path integral prescription and find the semi-classical contributions to the wave function. Exact formulae are obtainable for certain contributions and otherwise the limits of large and small anisotropy (for the pure vacuum case) and large spatial volume or small anisotropy (for the case with a positive cosmological constant) are considered. For the pure vacuum case we find no rapidly oscillating semiclassical components in the wave function, and hence do not recover lorentzian space-time as a prediction of the no-boundary proposal. For the case with a cosmological constant the wave function does contain rapidly oscillating components and thus predicts approximately ...

454

Antioxidant properties of natural substances in irradiated fresh poultry  

Energy Technology Data Exchange (ETDEWEB)

This study was undertaken to determine if a combined treatment (marinating in natural plant extracts or vacuum) with irradiation could have a synergistic effect, in order to prevent the lipid oxidation resulting in the development of undesirable flavours. The fresh chicken legs were irradiated at 0,3 and 5 kGy. The fatty acids composition of lipids was identified using gas liquid chromatography. The effect of irradiation treatment combined with a pre-treatment on the fatty acids composition was followed. The day after irradiation, ten panallists were asked to evaluate, using the instruction scaling, the overall appearance, the odor, the flavor and the overall acceptability of the samples. The major fatty acids identified in lipids were oleic acid, palmitic acid, palmitoleic acid and stearic acid. Pre-treatments have a significant effect on linoleic acid (C18:2) and higher fatty acids. The unsaturated fatty acids derived from phospholipids appeared to be more ...

1998-06-01

455

All-metal divided vaccum joints with small force of sealing  

International Nuclear Information System (INIS)

The structure of a demountable vacuum joint designed for operation from -120 to +120 deg C is developed and tested. Requirements of especially low gas release from the materials used have been fulfilled; the same concerns low sealing efforts, repeated action and keeping tightness under loads, indium being used as a sealant. Experimental studies of demountable vacuum joints, dia 100,125,140,160,180 and 200 mm, with an indium sealant permit to make the following conclusions: 1. The joints are sealed at sealing specific efforts of 0.4 kg/mm (without considering atmospheric pressure). 2. The joints retain tightness at opening and closing a cover five times and under +-120 deg C. 3. To ensure repeated operation of the joint with continued stable sealing effort, one should make sure the sealed surfaces coincide at repeated sealing. 4. When operating demountable vaccum joints with indium sealant, one must take into account the time factor, since time ...

456

(Electronic and structural properties of individual nanometer-size supported metallic clusters)  

Energy Technology Data Exchange (ETDEWEB)

The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their ...

1991-11-01

457

{sup 242m}Am fueled nuclear battery  

Energy Technology Data Exchange (ETDEWEB)

A nuclear battery based on the direct energy conversion of the fission products is presented. Such energy conversion is possible by using a nuclear reactor with ultra-thin fuel elements of 0.2 {mu}m of {sup 242m}Am. The amount of nuclear fuel is 376 g and the dimensions of the battery are 2.4x2.4x2.4 m{sup 3} (including the vacuum spacing), with a BeO moderator and Be electrodes. The total power of the reactor is 10.6 MW and the electrical power is 0.652 MW.

2004-10-01

458

Weyl gauge, Schwinger terms and bosonization in light-front field theory  

Energy Technology Data Exchange (ETDEWEB)

A systematic study of non-perturbative quantum structure of the massive light-front Schwinger model and QED(3+1) in the continuum formulation is outlined. The light-front Hamiltonian and field algebra are derived in the Weyl gauge using the Dirac-Bergmann constrained quantization. Unitary transformation to the light-cone gauge representation is performed and the gauge-invariant fermi field is constructed. The importance of the Schwinger term in the current-current commutation relations for the derivation of the fermionic vacuum structure and bosonization in two dimensions is indicated.

2002-04-01

459

Tubular packs Mo-AlN-Mo: long-term thermal and corrosion resistance  

International Nuclear Information System (INIS)

Study results on long-term thermal and corrosion resistance of packs with electro-insulation layer of aluminium nitride are presented. Structural changes of nitride ceramics and contact zones between metal and ceramics are considered. It is shown that multilayer metallo-ceramic packs, manufactured by gas-phase technology have high electro- and thermophysical properties, high thermal and corrosion resistance relative to cesium vapor, vacuum density as well as high thermo-resistance. 8 refs., 4 figs.

460

The Bevatron liquid nitrogen circulation system  

Science.gov (United States)

A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.

1987-03-01

461

Tachyons: may they have a role in elementary particle physics  

Energy Technology Data Exchange (ETDEWEB)

The possible role of space-like objects in elementary particle physics (and in quantum mechanics) is reviewed and discussed, mainly by exploiting the explicit consequences of the peculiar relativistic mechanics of Tachyons. Particular attention is paid: (i) to tachyons as the possible carriers of interactions; (ii) to the possibility of ''vacuum decays'' at the classical level; (iii) to a Lorentz-invariant bootstrap model; (iv) to the apparent shape of the tachyonic elementary particles and its possible connection with the de Broglie wave-particle dualism. (author).

1985-01-01

462

Structure and electrical resistance of dispersion-strengthened vacuum-deposited Cu?Al2O3 nanocomposites  

British Library Electronic Table of Contents (United Kingdom)

Methods of X-ray diffraction and transmission electron microscopy were used to study the microstructure of dispersion-strengthened Cu-Al2O3 nanocomposites obtained by the method of simultaneous deposition of Cu and Al2O3 from the vapor phase. The effect of the size of particles of the oxide (Al2O3) and of their content on the electrical resistance of the composite has been considered. The results obtained make it possible to suppose that the main structural factor that determines the electrical resistance of the composite are nanodispersed particles of Al2O3 with a size of less than 20 nm.

2011-01-01

463

Spontaneous radiation and lamb shift in three-dimensional photonic crystals  

Science.gov (United States)

Spontaneous emission in photonic crystals with anisotropic three-dimensional dispersion relation is studied. If the upper level is below a characteristic frequency omega(1), or above omega(2), or between omega(1) and omega(2), the radiation is a localized field with a frequency in the band gap, or a propagating field with a frquency in the band, or a diffusion field, respectively. An analytical expression for the Lamb shift is obtained. The Lamb shift for the current case is small compared to that in an ordinary vacuum or in one- or two-dimensional photonic crystals due to lower density of states. PMID:11017227

2000-03-01

464

Quantum Darwinism in quantum Brownian motion: the vacuum as a witness  

CERN Document Server

We study quantum Darwinism -- the redundant recording of information about a decohering system by its environment -- in zero-temperature quantum Brownian motion. An initially nonlocal quantum state leaves a record whose redundancy increases rapidly with its spatial extent. Significant delocalization (e.g., a Schroedinger's Cat state) causes high redundancy: many observers can measure the system's position without perturbing it. This explains the objective (i.e. classical) existence of einselected, decoherence-resistant pointer states of macroscopic objects.

2007-01-01

465

Progress in construction of the LHC  

CERN Document Server

The Large Hadron Collider (LHC) project, approved by the CERN Council in December 1994, has now fully entered its construction phase, with the detailed technical definition of the major systems, and the adjudication of a number of large procurement contracts. We first recall the main features and characteristics of the LHC, report on the advances in definition of the layout and optics as well as on preparation of the injector complex, and review recent progress in the key technical systems of the main ring: magnets, cryogenics and vacuum, as well as civil construction, which has started following acceptance by authorities in the Host States.

1998-01-01

466

Phenomenological interaction between current quarks  

International Nuclear Information System (INIS)

We construct a phenomenological model which describes the dynamical chiral symmetry breaking (DCSB) of a QCD vacuum and reproduces meson spectra. Quark condensates, the pion decay constant, and meson spectra are well reproduced by the phenomenological interaction which consists of a linear confining potential, a Coulombic potential, and the close-quote t Hooft determinant interaction. In this model, the close-quote t Hooft determinant interaction plays an important role to not only the mass difference between the #eta# and #eta#"' mesons, but other meson masses through DCSB. copyright 1997 The American Physical Society.

467

New methods of production of titanium alloy ingots  

International Nuclear Information System (INIS)

Production of titanium alloys from the mixture containing large amounts of metallurgy wastes is very promising. It is shown that unlimited possibilities of the waste material use in the mixture (up to 100%) are provided by garnissage melting, the size of the cast being limited only by that of the vessel. With garnissage being used as a consumed electrode the metal is refined from hydrogen and the blank ingots to serve as consumed electrodes in electro-slag remelting are chemically homogeneous. The ingots thus obtained have dense structure, rather fine grain homogeneous chemical composition, are no less pure than those obtained by vacuum arc remelting and provide for economic savings.

468

Method for harvesting, cleaning, and treating achenes of guayule (parthenium argentatum gray)  

Energy Technology Data Exchange (ETDEWEB)

Procedures are described to mechanize partially harvesting, cleaning, and pretreatment of guayule achenes. Achenes are harvested with a vacuum insect net and cleaned by a series of screening, threshing, and forced air separations, then treated to overcome seed coat impermeability in a semiautomatic system that presoaks, treats with 0.5% sodium hypochlorite, and rinses. Achenes may be sown immediately or dried for storage. Procedures outlined involve commercially available equipment with a minimum of custom construction and are adaptable to small or large operations. (Refs. 11).

1981-06-01

469

Mechanical Properties of Carbon Nanotubes / Hydroxyapatite Composites Prepared by Spark Plasma Sintering  

International Nuclear Information System (INIS)

In this study, Multi-Walled Carbon Nanotubes (MWCNTs) / Hydroxylapatite (HAp) composites were made to improve mechanical properties by using Spark Plasma Sintering (SPS) method. Slurry 6 mol of CaHPO4#centre dot#2H2O (DCPD), 4 mol calcium hydroxide and MWCNTs were mixed and sintered by using SPS at 5-120 MPa pressure, 1200-1250 deg. C and in vacuum or N2 atmosphere. The fracture toughness of sintered MWCNTs/HAp composites was increased.

2006-05-05

470

MITL - A 2-D code to investigate electron flow through non-uniform field region of magnetically insulated transmission lines  

Science.gov (United States)

Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.

1979-01-01

471

Loss of flow accident analysis of a water-cooled fusion reactor  

International Nuclear Information System (INIS)

Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)

2003-08-25

472

Kaon properties in (proto-)neutron star matter  

British Library Electronic Table of Contents (United Kingdom)

Abstract. The modification of kaon and antikaon properties in the interior of (proto-)neutron stars is investigated using a chiral SU(3) model. The parameters of the model are fitted to nuclear-matter saturation properties, baryon octet vacuum masses, hyperon optical potentials and low-energy kaon-nucleon scattering lengths. We study the kaon/antikaon medium modification and explore the possibility of antikaon condensation in (proto-)neutron star matter at zero as well as finite temperature/entropy and neutrino content. The effect of hyperons on kaon and antikaon optical potentials is also investigated at different stages of the neutron star evolution.

2010-01-01

473

Ion motion and finite temperature effect on relativistic strong plasma waves  

CERN Document Server

The influence of motion of ions and electron temperature on nonlinear one-dimensional plasma waves with velocity close to the speed of light in vacuum investigated. It is shown that although the wavebreaking field weakly depends on mass of ions, the nonlinear relativistic wavelength essentially changes. The nonlinearity leads to the increase of the strong plasma wavelength, while the motion of ions leads to the decrease of the wavelength. Both hydrodynamic approach and kinetic one, based on Vlasov-Poisson equations, are used to investigate the relativistic strong plasma waves in a warm plasma. The existence of relativistic solitons in a thermal plasma is predicted.

1998-01-01

474

Instanton contributions to the $\\tau$ decay widths  

CERN Document Server

Contrary to some previous claims, we find a sizable instanton contribution to the finite energy sum rule used to extract the value of the strong coupling from the measured $\\tau$ decay widths. It is of the same order of magnitude as standard nonperturbative corrections induced by vacuum quark and gluon condensates. Our result indicates that there might be no hierarchy of power corrections in finite energy sum rules at the scale of $\\tau$ mass. Therefore, the standard nonperturbative corrections do not necessarily improve the accuracy of the theoretical predicition, but can rather be used to estimate an intrinsic accuracy of the pure perturbative calculation, which turns out to be rather high on this evidence, of order one percent.

1993-01-01

475

Innovative technology summary report: in situ air stripping using horizontal wells  

Energy Technology Data Exchange (ETDEWEB)

In situ air stripping (ISAS) technology was developed to remediate soils and ground water contaminated with volatile organic compounds (VOCs) both above and below the water table. ISAS employs horizontal wells to inject (sparge) air into the ground water and vacuum extract VOCs from vadose zone soils. The innovation is creation of a system that combines two somewhat innovative technologies, air sparging and horizontal wells, with a baseline technology, soil vapor extraction, to produce a more efficient in situ remediation system.

1995-04-01

476

In situ bioremediation using horizontal wells. Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

In Situ Bioremediation (ISB) is the term used in this report for Gaseous Nutrient Injection for In Situ Bioremediation. This process (ISB) involves injection of air and nutrients (sparging and biostimulation) into the ground water and vacuum extraction to remove Volatile Organic Compounds (VOCs) from the vadose zone concomitant with biodegradation of the VOCs. This process is effective for remediation of soils and ground water contaminated with VOCs both above and below the water table. A full-scale demonstration of ISB was conducted as part of the Savannah River Integrated Demonstration: VOCs in Soils and Ground Water at Nonarid Sites. This demonstration was performed at the Savannah River Site from February 1992 to April 1993.

1995-04-01

477

In situ bioremediation using horizontal wells  

Energy Technology Data Exchange (ETDEWEB)

In Situ Bioremediation (ISB), which is the term used in this report for Gaseous Nutrient Injection for In Situ Bioremediation, remediates soils and ground water contaminated with volatile organic compounds (VOCs) both above and below the water table. ISB involves injection of air and nutrients (sparging and biostimulation) into the ground water and vacuum extraction to remove .VOCs from the vadose zone concomitant with biodegradation of VOCs. The innovation is in the combination of 3 emerging technologies, air stripping, horizontal wells, and bioremediation via gaseous nutrient injection with a baseline technology, soil vapor extraction, to produce a more efficient in situ remediation system.

1995-04-01

478

Improved four-stage accel-decel production of low energy highly stripped heavy ions  

Energy Technology Data Exchange (ETDEWEB)

The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.

1983-04-01

479

Group classification of the Sachs equations for a radiating axisymmetric, non-rotating, vacuum space-time  

CERN Document Server

We carry out a Lie group analysis of the Sachs equations for a time-dependent axisymmetric non-rotating space-time in which the Ricci tensor vanishes. These equations, which are the first two members of the set of Newman-Penrose equations, define the characteristic initial-value problem for the space-time. We find a particular form for the initial data such that these equations admit a Lie symmetry, and so defines a geometrically special class of such spacetimes. These should additionally be of particular physical interest because of this special geometric feature.

2006-01-01

480

Getter pumping  

CERN Document Server

A surface may provide a useful pumping action when able to retain adsorbed gas molecules for the duration of a given experiment. To fulfil this condition at room temperature, strong binding forces, as those resulting from chemical reactions, are required. Materials able to react with gases to form stable chemical compounds are called getters. The two main families of getters (evaporable and non-evaporable, or NEG) are presented and discussed. Special emphasis is placed on the NEG strips currently used for the vacuum systems of particle accelerators, and on the newly developed NEG thin-film coatings, in view of their possible future applications.

2007-01-01

481

Gas-liquid phase equilibrium in the system carbon dioxide-hexametapol (hexamethylphosphoramide)  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated phase equilibria in the system carbon dioxide-hexametapol. Vacuum-distilled solvent of ''pure'' grade was used. The solubility of CO/sub 2/ in hexametapol under pressures at various temperatures and the temperature dependence of the Henry's law coefficient is show. It is concluded that the solubility of carbon dioxide in hexametapol in the temperature and pressure ranges corresponding to the operating conditions of industrial equipment for removing CO/sub 2/ from gases conforms to the Krichevskii-II'inskaya equation. The experimental data can be used for equipment design.

1985-09-01

482

Final design and manufacturing of the Cryolegs of the W7-X-superconducting coil support system  

Energy Technology Data Exchange (ETDEWEB)

One of the most complicated tasks during the assembly of the Wendelstein W7-X is the installation of the superconductive coil system. The entire magnet system is enclosed between the Outer Vessel and the plasma vessel in high vacuum at 4 K. The coils are supported by a support structure, the Central Support Structure (CSS). The CSS carries all 70 coils, and it is designed as a closed ring made of 5 modules (10 half modules). The whole structure is supported by 10 Cryolegs which rest on the machine base. This paper describes the final design and manufacture of these Cryolegs.

2008-12-15

483

Fabrication of the 320-CM-OD all-ceramic ZT-40 torus  

International Nuclear Information System (INIS)

The fabrication of the ZT-40 torus, a large complex all-ceramic toroidal plasma containment vessel, is described. Several glass sealants covering the temperature range of 500 to 1300"0C, were developed and used to ''braze'' segments of the torus together, sapphire windows to the torus and the required pump-out and diagnostic parts to the ceramic vacuum vessel. Designs of window seals were developed that allowed sealing of the sapphire windows in a vertical position with minimum sealing glass flow.

484

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

485

Electrical conductivity of radiation-processed wood polymer composites  

International Nuclear Information System (INIS)

Two species of wood, viz. Haldu (Adina Cordifolia) and Jamun (Syzygium Cumini) were vacuum-impregnated with two styrene-based monomer systems and polymerized in situ with gamma radiation from a cobalt-60 source. The electrical conductivity of these specimens was determined at various polymer loadings under dry conditions, after wetting and after wet recovery as per ASTM standards. The water absorption characteristics are also presented. The results are discussed with special reference to the role of water. Potential applications are also discussed. 7 figures.

1978-01-01

486

ESR study on the reaction of MMA with the radicals in pre-irradiated wood  

International Nuclear Information System (INIS)

The nature of radicals in wood irradiated in vacuum was studied by ESR method. The decay rate of radicals changes in three temperature ranges. Long-lived radicals are very stable at 298"0K, at which the wood-plastics composite has often been studied. The number of radicals formed by irradiations shows fairly good agreement with the total number of radicals in each isolated wood component. The graft copolymerization of MMA to irradiated wood was also studied by means of ESR, and it was found that PMMA propagating radicals are formed in irradiated wood. These radicals are probably formed by the result of graft copolymerization of MMA of wood. (auth.).

1975-01-01

487

Damage mechanism in high temperature fatigue of alloy 800 H  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate the influence of grain boundary cavities on the life time of Alloy 800 H various fatigue tests have been performed at 800/sup 0/C. Cavity formation has been observed only in asymmetrical tests. Compared to the corresponding symmetrical tests, the cyclic life time is shorter. As the cavitation damage increases, the ratio of life times in vacuum and in air steadily decreases from an initial value of 5. In extreme cases it can reach a value close to 1. In this case, cavitation damage dominates over the usual damage mechanism, which is cracks from the surface.

1986-09-01

488

Cosmic no-hair theorem in power-law inflation  

Energy Technology Data Exchange (ETDEWEB)

We prove a cosmic no-hair theorem for Bianchi models in power-law inflation. Provided that the potential of an inflaton {phi} is exp({minus}{lambda}{kappa}{phi}) with 0{le}{lambda}{lt} {radical}2/3 , we find that the isotropic power-law solution is the unique attractor for any initially expanding Bianchi-type models except type IX. For Bianchi type IX, this conclusion is also true if the initial ratio of the vacuum energy to the maximum three-curvature is larger than one half.

1992-02-15

489

Collective ion acceleration in systems with a virtual cathode  

International Nuclear Information System (INIS)

The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)

2002-11-30

490

Boring of full scale deposition holes using a novel dry blind boring method  

Energy Technology Data Exchange (ETDEWEB)

As a part of the Finnish radioactive waste disposal research three holes (the size of deposition holes) were bored in the research tunnel at Olkiluoto in Finland. A novel full-face boring technique was used based on rotary crushing of rock and removal of crushed rock by vacuum flushing through the drill string an the purpose of the work was to demonstrate the feasibility of the technique. During the boring test procedures were carried out in order to determine the effect of charges in operating parameters on the performance of the boring machine and the quality of the hole. (refs.).

1996-11-01

491

Beam lifetime and emittance growth in RHIC under normal operating conditions with the hydrogen gas jet, the cluster-jet and pellet targets  

International Nuclear Information System (INIS)

The inelastic scattering of the beam and the residual gas molecules in RHIC could represent one of the limitations on the beam life time and emittance growth. This report covers the dominant central nuclear collisions influence on the beam lifetime and transverse emittance growth. The cross sections for the beam-gas electron radiative captures are an order of magnitude smaller. The capture cross sections include the radiative and non-radiative capture, and the capture from the electron-positron pair creation from the 'vacuum capture'.

2010-09-01

492

All Optical Switch of Vacuum Rabi Oscillations: The Ultrafast Quantum Eraser  

CERN Document Server

We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.

2010-01-01

493

Adiabatic Rormation of a Matched-beam Distribution for an Alternating-gradient Quadrupole Lattice  

Energy Technology Data Exchange (ETDEWEB)

The formation of a quasiequilibrium beam distribution matched to an alternating-gradient quadrupole focusing lattice by means of the adiabatic turn-on of the oscillating focusing field is studied numerically using particle-in-cell simulations. Quiescent beam propagation over several hundred lattice periods is demonstrated for a broad range of beam intensities and vacuum phase advances describing the strength of the oscillating focusing field. Properties of the matched-beam distribution are investigated. In particular, self-similar evolution of the beam density profile is observed over a wide range of system parameters. The numerical simulations are performed using the WARP particle-in-cell code.

2010-02-02

494

Accelerated aging of EPDM and butyl elastomers  

Energy Technology Data Exchange (ETDEWEB)

This study was composed of three parts: a post cure study to optimize final properties of an ethylene-propylene-diene (EPDM) formulation, an accelerated aging study to compare the stress relaxation behavior of a butyl and an EPDM elastomer under compression, and a cursory evaluation of a new 70 Shore A EPDM. The optimum postcure for the EPDM was found to be 2 to 4 hours at 182{degrees}C in a vacuum. The EPDM was also shown to have superior aging characteristics compared to the butyl and is recommended for use instead of the butyl material. The physical properties for new 70 Shore A EPDM are satisfactory, and the stress relaxation behavior was only slightly inferior to the other EPDM.

1996-06-01

495

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

496

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

497

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).