Self-magnetically insulated, high-voltage transmissionlines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam linevacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)
Due to biological effects of magnetic fields of high voltage transmissionlines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmissionlines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmissionlines and the results are analyzed.
A method, which estimates the lightning performance of high voltage transmissionlines based on the Monte-Carlo simulation technique, is described in this paper. The average number of faults which occur in a transmissionline, dividing them in single-phase and three-phase faults, as well as the average grounding resistances of the transmissionlines are calculated. The method is applied, on several operating Greek transmissionlines, showing good correlation between predicted and field observation results. The proposed method can be used as a useful tool in the design of electric power systems, aiding in the right insulation dimensioning of a transmissionline.(author)
As an interim report on the study on vibration of transmissionlines when gust is blowing, this paper introduces events of confused and other contacts between transmissionlines, photographing of transmissionline vibration, physical measurement on transmissionline response, and development of simulation software. Events of confused contacts of high-voltage transmissionlines with overhead ground wires have the following common conditions: gust blows nearly perpendicularly to the line direction; no obstacles exist in upwind directions; the wind blows upward or downward against high-voltage transmissionlines; and size of the high-voltage transmissionlines is 25 mm{sup 2}. ...
The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmissionlines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.
The mutual inductance between parallel transmissionlines influences the locating of the transmissionline faults. A fault location algorithm for parallel lines developed in this paper takes into account the magnetic coupling between parallel lines. The paper presents a detailed description of the developed algorithm and test results performed on a simplified real transmissionline. The obtained error is less than 0.5 percent in most cases. Also, the developed algorithm is not sensitive to typical fault parameters, such as: resistance, type, location, and incidence angle. 7 refs, 4 figs, 12 tabs
Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ...
Since 1985 the operating sections of the 1200 kV AC Ekibastuz-Urals transmission system were used for a variety of field studies on a wide range of technological problems associated to high voltage transmissionlines. The tests performed confirmed correctness of the main engineering and design decision made at development stage and demonstrated that such transmissionlines are reliable and efficient. 3 figs.
This paper is a tutorial discussion of the basic principles of ground relaying for high voltage and extra high voltage transmissionlines. Three different HV configurations are considered: Long lines, lines with a weak mid-point station, and mutually-coupled lines. Application criteria for EHV circuits are also discussed, and specific setting calculations are included where appropriate.
OBJECTIVES: To reassess the risk of leukaemia associated with residential exposure near high voltage transmission electric lines of 49 kV and above in view of the recent publications. METHODS: Through...Full Text Available
Overhead, high power transmissionlines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmissionlines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmissionline.
Overhead, high power transmissionlines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmissionlines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmissionline.
With the increasing use of high voltage alternating current (HVAC) transmissionlines there is a growing concern among the public about possible human health effects resulting from exposure to the electric fields associated with these lines. While there is no definitive evidence of such effects, mounting public fear and activism over hypothesized health risks is already causing delays in the licensing and constuction of major power transmission facilities, and is encouraging the formation of regulatory policy. This paper briefly reviews the concerns, biological effects data and standards for HVAC transmissionlines.
An improved method to design suitable compensating schemes for extra high voltage transmissionlines is presented. The technique is general and effective and will greatly facilitate the design of the optimal compensation scheme for extra high voltage transmissionlines. The technique is illustrated for a typical 500 kV system. The equations developed here for voltage maxima and minima along the transmissionline eliminate the need for point-to-point computation of the voltage profile. The controversy existing in the literature over the problem of making a choice between pi and tee configurations has been removed and it is established with a mathematical proof that the tee configuration requires compensating elements of lower ratings.
To determine the transient response of linear and time-invariant transmission systems which are only described for discret frequencies, it is possible to find a good functional approximation by means of the generalized impulse method, combined with the most important natural spline-interpolation functions of the first and the third degree. This procedure has been applied to calculate the step response of the transient behaviour of the zero-sequence impedance system of the high voltage transmissionline.
Silicone-rubber washers function as damping and articulating elements in cast-aluminum spacers that separate bundle subconductors in each phase of extra-high-voltage transmissionlines. Spacer/dampers are located every 3 ft. along transmissionlines on Canada's first operational 500 and 735 kV system.
The audible noise produced by corona on high-voltage transmissionlines has several characteristics that differentiate it from other community noises. Transmissionline noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.
The prediction of faults on high voltage transmissionlines requires the detection of incipient faults, which is implemented by detection of the radio noise due to contaminated insulators, insulation deterioration, and improver connections. It is shown that the radio noise due to incipient faults is separable and identifiable from normal transmissionline radio noise, hence faults can be predicted.
This paper presents some results of lightning induced over voltages for a typical high voltage transmissionline configuration. The authors developed an elaborated electromagnetic coupling between the lightning channel and characteristics and the resulting induced overvoltage. The lightning current parameters, for local data, in order to determine the occurrence severity for high voltage transmissionlines. (author)
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmissionline voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmissionline conductors. Transmissionline noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmissionlines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmissionline voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmissionline conductors. Transmissionline noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmissionlines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmissionline voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmissionline conductors. Transmissionline noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmissionlines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, ...
The invention is a mechanism for retaining an electrical transmissionline. In one embodiment of the invention it is a system for retaining an electrical transmissionline within downhole components. The invention allows a transmissionline to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmissionline to withstand the tension and compression of ...
Overloaded transmissionlines are only part of the problem. The ability of the network to carry power is also limited by the supply of reactive power and by frequency stability. Reactive power problems must be corrected in minutes, frequency stability problems in seconds. There is no way that market forces can handle these problems. Reactive power must be supplied to all long transmission and distribution lines to compensate for the loss of reactive volt-amperes - and resulting voltage drop - in the reactance along the line`s length. 7 figs.
During the last several years, audible noise produced by high voltage transmissionlines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.
The purpose of this study was to assess the effect of a 735-kV transmissionline on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available
Abstract Voltage sag caused by faults on an electric power transmissionline is one of the most intractable power quality issues for both utility companies and customers. The fault in power system randomly exists along transmissionlines due to the combination of many uncertain factors. To predict and assess the annual expected sag frequency (ESF) deriving from the faults along lines, a stochastic based method that employs maximum entropy principle, namely the maximum entropy probability method (MEPM), has been introduced in this paper. Moreover, various types of faults have been considered systematically. With the fault line intervals and the sample moments taken into account, the discrete values of distribution probability of fault locations along the transmissionlines have been estimat...
Corona from bare conductors of electrical overhead power lines is studied in this article. Its origin, as well as, its bad influences over communication systems are both studied, yet. Line`s models are defined, in order to be able the examination of Corona on line`s cables. Formulas for the surface electrical gradient calculations are shown. (author) 2 refs.
CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the ...
Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmissionlines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. ...
A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmissionlines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault ...
Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmissionlines. 500 kV and above. Therefore this paper describes audible noise characteristics of 6 X 480 mm{sup 2} conductor bundle in KEPRI 765 kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765 kV TransmissionLine was developed using this results. (author). 4 refs., 4 figs., 4 tabs.
The magnitude of electric and magnetic fields around a high voltage three-phase transmissionline was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmissionlines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmissionlines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.
The magnitude of electric and magnetic fields around a high voltage three-phase transmissionline was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmissionlines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmissionlines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.
During the early 1970s, controversy developed over the possible biological effects of electric fields from new 500-kilovolt and 765-kilovolt transmissionlines. This, along with growing interest in advancing transmission voltage into the ultrahigh-voltage range (1000 kilovolts and above), led to the initiation of numerous research projects. Several reviews of this research by scientists in the US and other countries indicate that transmissionlines have not been proven to be a health hazard to people or animals. The issue remains controversial, however, because research has confirmed some subtle effects of electric fields, and because it is an inseparable part of the public opposition that often accompanies the siting of high-voltage transmissionlines. In addition, there is renewed interest in magnetic fields, including a possible ...
It is well known that the lightning protection of transmissionlines is exclusively relying on their correct initial design. Although detailed engineering studies are usually performed by electric power utilities for the design of new transmissionlines, there are reported cases where the design is based simply on tradition or on utilities' standardization policy. In this paper, the lightning protection of high-voltage transmissionlines is faced as an optimization problem where optimum design parameters are calculated for the lines, relating their cost with the lightning failures' cost, aiming to reduce or even eliminate lightning failures. The optimization method considers all the available protection means, i.e. ground wires and surge arresters. In order to validate the effectiveness of the proposed method, it is applied ...
My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.
This paper presents a method for the optimal design of high voltage transmissionlines taking into consideration shielding and backflashover failure rates. The minimization of suitably defined performance indices, which relate the failures caused by lightning in a transmissionline to both line insulation level and tower footing resistance, is aimed. Optimum values for both line insulation level and tower footing resistance are calculated. The method is applied on several operating Hellenic transmissionlines of 150 and 400kV, respectively, carefully selected among others, due to their high failure rates during lightning thunderstorms. Special attention has been paid on open loop lines, where a possible failure could bring the system out of service causing significant problems. The obtained design ...
Results obtained on induced current and voltage caused by a high voltage transmissionlines running parallel at a trolley bus contact lines, are presented. A computer program in Basic language, was developed to calculate the electric induction, problems of safety, a theoretical development and mathematical model of the electric factors between two lines (inductor and induced) are also discussed. 11 figs., 1 tab., 8 refs.
The use of irrigation systems in the proximity of high voltage transmissionlines is increasing. This study examines the induced voltages and currents on a pivotal irrigation system operating under a 765 kV line. With a few simple precautions such as a system can be operated in complete safety. 1 ref.
A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant...Full Text Available
A computer-aided design procedure has been developed for the series compensation of an extra high voltage line with a compensating network connected at one or the other end or both ends. Higher degree polynomial equations are derived in terms of compensating elements to compute the network parameters for optimum received power with constrained capacitor terminal voltage, safe line current, Ferranti voltage and transient stability. It is shown that series capacitors located at both ends provide the most effective means from the viewpoint of power transmission capability in either direction, transmission efficiency and series capacitor rating in comparison with a capacitor located at one or the other end.
High-voltage transmissionlines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmissionlines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d`Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.
High-voltage transmissionlines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmissionlines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d'Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.
Comparisons of the 60 Hz electric field exposures associated with high voltage transmissionlines to those associated with common household sources can provide an important input to regulatory decisions that involve transmissionline fields. Electric blankets are of interest in this context because the exposures they produce are among the most intense and prolonged of any of the household sources of 60 Hz electric field exposure. This paper presents a theoretical analysis of the body surface fields induced by electric blankets. Electric blanket exposure intensities are compared to those associated with transmissionlines.
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuumtransmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
... Microwaves, radio waves, and low-frequency electromagnetic fields from high-voltage transmissionlines . Non-Methane Hydrocarbon (NMHC): The sum of all hydrocarbon air ...
A number of epidemiological studies indicate an association between depression and proximity to high voltage transmissionlines. These studies have been criticized, however, for using surrogate measures of electromagnetic fields (EMFs) and unstandardized measures of depression. In an effort to overcome these limitations, the Center for Epidemiological Studies Depression (CES-D) scale was administered to 152 women living either adjacent to a transmissionline or one block away. Results indicate that homes adjacent to the transmissionlines have an average EMF level of 4.86 milligauss at their front door and those one block away have an average of 0.68 milligauss. There was no significant difference in CES-D scores between the groups, controlling for demographic variables. There appeared to be an increase in other health effects, including cancer and miscarriages, ...
The company reports that with the help of outside companies, they completed all major fixes including high-voltage transmissionlines to neighborhood ...
...Systems, UWA investigating rate uplift effects of shallow foundation systems associated with high voltage transmissionline support towers. This work was funded by National Grid, ...
The paper presents an alternative approach for the studies of high voltage transmissionlines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmissionlines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmissionlines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and ...
miles of high-voltage transmissionlines with 12 intercon- nections to electricity systems in New York and Canada. As of 1 March 2003, ISO New England has ...
Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmissionlines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmissionlines. Western proposes to conduct maintenance and improve its access roads for these two transmissionlines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is ...
... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmissionlines. ...
...smart grid applications where you could place them very close to the high-voltage transmissionlines , very close to transformers and so on. Photo:...
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmissionlines near the Gering Substation in Gering, Nebraska. The transmissionlines are both located in Scotts Bluff County, Nebraska. The transmissionlines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmissionlines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmissionline and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV ...
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmissionlines near the Gering Substation in Gering, Nebraska. The transmissionlines are both located in Scotts Bluff County, Nebraska. The transmissionlines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmissionlines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmissionline and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV ...
The properties of ZnO films were investigated as functions of annealing temperatures in H2/Ar and vacuum. The resistivities and mobilities of ZnO films decreased with increase of annealing temperatures in vacuum and H2/Ar ambients. However, the carrier densities of ZnO films increased with increase of annealing temperatures in vacuum and H2/Ar ambients. The resistivities of ZnO2 films annealed at 300degreeC were 2186cm and 798cm in H2/Ar and vacuum ambients, respectively. The resistivities of ZnO films annealed in vacuum and H2/Ar ambients at 600degreeC were similar with 0.040cm and 0.035cm, respectively. The hydrogen donor was more dominant than the oxygen vacancy or Zn interstitial donor in ZnO films annealed in ambient H2/Ar at low temperatures. The average optical transmission was >82%...
This booklet presents safe practices that you should follow if your activities take you near high-voltage transmissionlines. It documents information that has generally been available to the public.
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmissionlines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmissionlines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken ...
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmissionlines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmissionlines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in ...
A methodology for assessing the lightning performance of Hellenic high voltage transmissionlines has been developed. Its main advantage is that the analysed transmissionline is divided into regions and the analysis is conducted separately for each one region, taking into account the individual characteristics, which exist in each one of them. The developed approach intends to offer more accuracy in the assessment of lightning performance of Hellenic high voltage transmissionlines and of similar lines, where they run at the same time through a plain region, a coastline and/or a mountainous region. The aims of the paper are to describe in detail the proposed methodology and to present results obtained by its application on operating Hellenic transmissionlines of 150 and 400 kV. The computed results ...
High-voltage transmissionlines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmissionlines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of ...
A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant or consistent relationships between exposure to a high voltage DC power line and the perceived health problems that were measured. The sample was not, however, large enough to draw statistically significant conclusions regarding possible health effects with a very low incidence.
The authors present a new concept: 'adaptive optimal reclosure' under transmissionline faults by integrating the adaptive and optimal reclosure techniques. Simulation studies prove that the proposed technique is able to first detect the persistence time of fault path arc and then capture the optimal reclosure time, thereby enhancing system stability. (author)
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmissionline. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
This paper investigates the calculation of availability for parallel transmissionlines (two or more) in the same tower or on the same right of way. As in many studies, the development of mathematical models is an important step. The models are justified using historical data and known characteristics of power system elements. A statistical method was used to generalize the failure rate and repair rate from real operating data. Application of the new model (which combines common-mode, simultaneous independent, and dependent outages) is discussed.
Populations living close to high-voltage transmissionlines often have residential magnetic field exposures in excess of 1 microT, and sometimes over 2 microT. Yet, populations studied in most epidemiologic...Full Text Available
The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmissionlines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmissionlines.
This paper shows a computerized system, that adopt a statistical methodology and simultaneous measurements of wind velocity and environment temperature, as an experiences at the power transmissionlines with environmental monitoring systems. 9 figs., 16 refs.
The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmissionlines was described. 4 refs., 1 tab., 5 figs.
The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmissionlines was described. 4 refs., 1 tab., 5 figs.
When constructing new high-voltage transmissionlines landscape aspects play a more and more important role. The project described is particularly interesting as it demonstrates that it is possible to find acceptable solutions for everyone if all partners are prepared to make concessions. The article also describes a new concept for the connection of concrete tower elements. (orig.).
A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmissionlines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.
An approach for classification of transmissionline faults is presented. The approach is based on fuzzy logic and requires the consideration of the samples of three phase currents at one end of transmissionline. To illustrate the effectiveness of the proposed approach extensive simulation studies, using EMTP and MATLAB, have been carried out for different types of fault considering wide variations in the operating conditions. (author)
In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmissionline faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at different locations along the transmissionline and an attempt has been made to correctly identify ...
Accuracy of an LLP system and a lightning frequency map is evaluated by using transmissionline faults in Hokuriku area from November in 1993 to October in 1996. The accuracy and efficiency of the system were calculated by statistical methods. From the above results, the lightning frequency map with 10 minutes meshes was proved capable of replacing the Isokeraunic Level Map with 15 minutes meshes used now for lightning protection design. However, the correlation between the number of detected lightning flashes and transmissionline faults in each mesh was found to be week. This result suggests that more detailed analysis taking account of the length of transmissionlines in each mesh is necessary. The correlation is stronger in winter than in summer, despite the fact that there is difference in the lightning current distribution in each mesh in winter. This ...
Construction of high voltage transmissionlines in a difficult hilly terrain within the limited time frame calls for the adoption of modern management tools for controlling the progress. The activity on node network system for such works, in which parallel and overlapping activities are involved is highly useful and is being used in Himachal Pradesh State Electricity Board. This network system has helped the Board to provide an effective and efficient mode of progress reporting at all levels of functioning. A remarkable example is the control of construction of 190 km - 200 kV dc transmissionline within four years and six months.
The types of investigations undertaken to test for possible biological effects of extremely low frequency electric fields have been numerous. However, neither animal and plant experimentation nor clinical studies nor experience with operating extremely high voltage transmissionlines have to date provided convincing evidence of a harmful effect from exposure to electric fields associated with transmissionlines in spite of numerous attempts to find such effects. Analysis of internal fields and currents supports these observations as the levels appear to be too low to affect mammalian cells. Thus, while one can never prove the negative (i.e. that there is no effect), the overwhelming body of evidence indicates that the electric fields associated with high-voltage lines have no deleterious biological effects. (author).
The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmissionlines, more specifically in the 500 kV transmissionlines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmissionlines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are ...
The 220 kV Ch{bar u}si Trunk Line, now transmitting a maximum of 300 MW of electricity between the Ch{bar u}goku area of Honsh{bar u} and Shikoku island, is expected to be inadequate in the 1990's due to the rise in electrical demand. Therefore, to strengthen this interconnection, a new 500 kV transmissionline was proposed. The most significant feature of this transmissionline is the installation of 500 kV cables along the bridges (the Seto Ohashi Bridge) which span the Inland Sea (Seto). This is the first 500 kV long-distance transmission cable line. It is also the first large-scale cable line in the world installed along various types of bridges (ten bridges; route length of the bridge portion approximately 8 km). This paper gives an outline of the Honsh{bar u}---Shikoku interconnecting ...
The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmissionlines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.
Aerial lines or cables, as one mainly energy transport path of electronic system when illuminated by HEMP, has been often modeled by field-to-transmissionline model. However, in many cases, authors too often encounter some confusing statements to the lines effects during experimental procedure. The aim of this paper is to present and discuss these cases, such as the electromagnetic environment above the ground plane, the contribution of the different electromagnetic field component to the induced current and voltage, variations of the load current for different line heights and ground conductivities etc. (authors)
A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmissionlines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.
Resonant overvoltages in EHV transformers can be initiated by transmissionline faults. A series of field tests were performed on the 151 mile long Kammer-Marysville 765 kV line in which a sequence of single line to ground faults were applied to one outside phase at 4 different locations. Fault location criteria and fault initiation procedures are presented. Oscillograms recorded the 3 phase response at both terminals of the line; one is transformer terminated, the other is open-ended. A frequency spectrum analysis of the waveforms is provided showing transient frequencies of sufficient magnitude and duration near the EHV transformer's resonant frequency to stimulate internal winding resonant overvoltages. Digital computer studies are presented and agree with the field tests quite favorably.
The paper reports the results of the studies performed at the Electric Research Center of ENEL (Italian National Electricity Board) in the field of compacting high voltage transmissionlines, from the point of view of dielectric and corona noise constraints. The results of switching impulse withstand voltage tests, performed on typical compact line insulation configurations, are given and optimization criteria of such insulation configurations in relation to switching impulse are outlined. The constraints regarding surface withstand voltage in polluted conditions of the above insulations are analyzed and the possibility of reducing their dimensions by using unconventional insulation materials is considered. Finally, evaluations of corona noise in the case of optimization of the line encumbrance from the point of view of dielectric constraints are given.
Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmissionlines are investigated. A method of analysis of traveling wave phenomena for three phase transmissionlines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmissionline equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the ...
Distance protection, differential protection and directional comparison schemes are presently used for protecting transmissionlines. Directional comparison relays are set to respond to faults in the protection zone without intentional time delay and are, therefore, used where high-speed fault clearing is needed. Artificial Neural Networks (ANNs) can handle most situations which cannot be defined sufficiently for finding a deterministic solution. The design and testing of an ANN for directional comparison protection of transmissionlines are presented in this paper. Training patterns were generated using voltage and current samples for faults at various locations along a transmissionline. The faults were simulated using an electromagnetic transient program and a sample three-phase power system. The performance of the proposed discriminator was checked using ...
This paper presents some situations, in which measurements of electromagnetic fields generated by transmissionlines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmissionlines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the report should include ...
Concerns are sometimes expressed about an alleged link between exposure to the extremely low frequency electromagnetic fields occurring in proximity to electricity networks or equipment. Transmissionlines are specifically mentioned. The underlying physical mechanisms are described by which electric and magnetic fields exist, with particular reference to high voltage transmissionlines. Epidemiological and laboratory studies are the two approaches used in research into the subject and the shortcomings inherent in many such studies and the inconsistencies in the results are mentioned. Some of the more recent epidemiological studies are referred to, also the possible interaction mechanisms between fields and the human body. The work of certain international and national bodies which were established to review the results of research into the alleged association between electromagnetic fields and ...
The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.
Wheeling electric power, the transmission of electricity not owned by an electric utility over its transmissionlines, is a term not generally recognized outside the electric utility industry. Investigation of the term`s origin is intriguing. For centuries, wheel has been used to describe an entire machine, not just individual wheels within a machine. Thus we have waterwheel, spinning wheel, potter`s wheel and, for an automobile, wheels. Wheel as a verb connotes transmission or modification of forces and motion in machinery. With the advent of an understanding of electricity, use of the word wheel was extended to be transmission of electric power as well as mechanical power. Today, use of the term wheeling electric power is restricted to utility transmission of power that it doesn`t own. Cogeneration refers to simultaneous production of electric and thermal ...
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuumtransmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
Comparative indices are given for the efficiency of phase control of remote-controlled self-compensating high-voltage transmissionlines, including a consideration of the power transfer effect between high-voltage line circuits. A description is given of certain circuit variations for performing the technical means of regulating phase shift, and their characteristics which make it possible to evaluate the effect of the phase regulators on the electrical transmission system are also given. An examination is made of problems concerned with the design of lines, relay protection, computation of transfer processes and dynamic stability as well as the computation of over-voltage when shutting off short circuits during amplified electromagnetic ties between line circuits.
The influence of low-frequency electromagnetic field irradiating by high-voltage transmissionlines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmissionlines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this ...
... biological effects of electromagnetic fields (EMFs) produced by high-voltage transmissionlines have come under intense scrutiny, mostly with respect ... biological effects of electromagnetic fields (EMFs...
Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)
The induction of voltages on pipelines and railroad signal wires can be a problem when high-voltage transmissionlines share the right of way. A handbook and two computer programs provide the analytic tools for utilities to avoid the problem.
Feed-forward (FF) artificial neural networks (ANN) and radial basis function (RBF) ANN methods were addressed for evaluating the lightning performance of high voltage transmissionlines. Several structures, learning algorithms and transfer functions were tested in order to produce a model with the best generalizing ability. Actual input and output data, collected from operating Hellenic high voltage transmissionlines, as well as simulated output data were used in the training, validation and testing process. The aims of the paper are to describe in detail and compare the proposed FF and RBF ANN models, to state their advantages and disadvantages and to present results obtained by their application on operating Hellenic transmissionlines of 150kV and 400kV. The ANN results are also compared with results obtained using conventional methods and real records of ...
Populations living close to high-voltage transmissionlines often have residential magnetic field exposures in excess of 1 [mu]T, and sometimes over 2 [mu]T. Yet, populations studied in most epidemiologic investigations of the association between residential magnetic field exposure and cancer typically have exposures below 1 [mu]T and frequently below 0.5 [mu]T. To improve statistical power and precision, it would be useful to compare high exposure populations with low exposure population. Toward this end, we have developed an automated method for identifying populations living near high-voltage transmissionslines. These populations likely have more highly exposed individuals that the population at large. The method uses a geographic information system (GIS) to superimpose digitized transmissionline locations on U.S. Census block location data and then extract ...
Single and selective pole tripping schemes may be used to maintain a desired level of system integrity while minimizing transmissionline expenditures. In general, these schemes will be most effective on those portions of the system where relatively few interconnections exist. While selective pole tripping may superficially appear to provide more margin than single pole schemes in the preservation of system stability, it seems unlikely that in those actual applications where single pole tripping is warranted that selective pole tripping will provide any significant advantages.
The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmissionlines, households), and magnetic alternating fields (high-voltage transmissionlines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).
This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmissionline. Initial tests performed on a crude oil transmissionline verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.
The paper outlines the underlying physical mechanisms by which electric and magnetic fields exist, with particular reference to high voltage transmissionlines. Epidemiological and laboratory studies are the two approaches used in research into the subject and the shortcomings and inconstancies in the results are mentioned. Recent epidemiological results are presented together with possible mechanisms between fields and the human body. Attention is drawn to the work of certain international and national bodies concerning the alleged association between electromagnetic fields and ill-health, and their conclusions are reported. Finally, the policy of the Electricity Supply Board in Ireland is outlined. 2 figs.
With the compensator-series equipment put into operation in 1992 - giving a performance of 330 Mvar - it was made possible for high-performance electronics to use a continuously variable, fully loaded power transmissionline and to regulate the energy flow and minimise overcurrent losses. As well as these technical qualities, this system could offer environmental advantages for European implementation. This would avoid the need to plan and construct new high voltage transmissionlines in order to meet increased demand. (orig.)
A broad-based, multidisciplinary research program is being conducted to study biological effects of electric and magnetic fields from high-voltage transmissionlines. Assistance and technical support for this program are reported. (DLC)
Statistical detail is given of the electricity generation and transmission systems in the UK. Breakdown by type of station, by fuel and the proportion generated by others apart from the generating or area boards is presented. Figures are provided for the various high voltage transmissionlines in terms of route and circuit length as well as the number of towers and the capacity of mains transformers.
This report presents the data and results of a site specific case study comparing costs of an overhead line with an underground circuit traversing the same route. The costs used for the overhead line are actual numbers for a line scheduled to be built by a utility. The underground circuit costs were developed using the same criteria of line rating, contingencies, and location. Often cost comparisons between overhead and underground lines are made using figures taken from studies with widely varying assumptions. This project attempts to provide a comparison by studying the costs of overhead and underground lines following the same route and using the same design assumptions. Caution must be used, however, in extending the results of this study beyond its original intent. It is site-specific and may be representative of only one area of the country. 9 refs., 23 ...
Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmissionlines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central ...
As part of the licensing process to construct a new 230 kV transmissionline on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmissionlines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission ...
A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmissionline faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the ...
In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde...
The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmissionlines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as ...
Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.
In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmissionline faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at differ...
The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.
The electrogeometric model cannot consider the influence of some parameters on the screening of the wire conductor of the H.V. lines. For analysing the influence of these parameters (the conductor potential, the influence of the distance from phase conductor to earth wire, the influence of the reducing factor of the striking earth distance, the earth slope, etc.), the Monte Carlo method is preferable. The influence of the earth slope on the screening effect of the wire conductor for different conditions is presented in this paper. (author)
The harmful effects of high-intensity electric fields on human beings are discussed. Formulas for determining the field strength of high voltage transmissionlines and track lines and experimental data of these effects on mice are given. Protective measures from these hazards are introduced. 18 references, 7 figures, 5 tables.
The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.
The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmissionline systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmissionline tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmissionline tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend ...
Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmissionlines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations ...
The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmissionlines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmissionlines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a ...
The contribution examines whether the construction of high-voltage transmissionlines without formal participation of local authorities is permissible. In this connection the question is also treated to what extent municipal co-determination in transmissionline construction represents a precondition for the permissibility of compulsory purchase measures. The individual issues treated are: the formal legal situation and current practice in the construction of electricity pylons; individual legal protection in connection with compulsory purchase; the construction of pylons without a construction licence as an infringement of the municipal right to self-government of local authorities; and the effects on the execution of compulsory purchase procedures of the illegality under Building Law of pylons constructed without approval. (RST).
An investigation of the intensity of electromagnetic radiation at a wavelength of 185nm emitted by a General Electric mercury discharge, germicidal lamp is described. From the measurement of the transmission of light as a function of wavelength from 185nm to 360nm, it was concluded that this type of germicidal lamp does not produce any biological or chemical effects through the 185nm line; the intensity of the 185nm line transmitted by the lamp was less than 0.1% of that for the 254nm line. Consequently, there was no discernable ozone production. (U.K.).
Power quality problems are caused by activities normal to utility operations such as maintenance outages and capacitor switching or events that are abnormal such as lightning strikes and equipment failures. Disconnection and reconnection of transmissionlines and transformers can cause switching surges, and are more severe on extra high voltage transmissionlines than high voltage lines. Capacitor switching can cause transients and harmonics that may affect sensitive equipment, and are the source of 3rd, 5th, 7th and 9th harmonics in the hundreds of hertz ranges. Overload, sudden loss of generating capacity and transmissionline faults are typical problems affecting system stability. Fault interruptions and reclosings can cause surges in the distribution system, and lightning strikes may cause voltage surges or dips due to arrester ...
Methods of X-ray diffraction and transmission electron microscopy were used to study the microstructure of dispersion-strengthened Cu-Al2O3 nanocomposites obtained by the method of simultaneous deposition of Cu and Al2O3 from the vapor phase. The effect of the size of particles of the oxide (Al2O3) and of their content on the electrical resistance of the composite has been considered. The results obtained make it possible to suppose that the main structural factor that determines the electrical resistance of the composite are nanodispersed particles of Al2O3 with a size of less than 20 nm.
Transmissionline faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmissionlines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmissionline only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmissionline ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several ...
Sixty-Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights-of-way (ROWs) with either 345- and 115-kV transmissionlines, or ROWs with only 115-kV transmissionlines; fifteen resided far from any transmissionlines. Personal exposure data for a single 24-hour period was acquired with the EMDEX. The EMDEX's event-marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: (1) 24-hr fixed-site bedroom measurement with a second EMDEX; (2) Spot measurements in at least three rooms of every residence; and (3) Spot measurements outside each residence. Residence near transmissionlines highly loaded during the measurement period was ...
The study of audible noise from high voltage transmissionlines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmissionlines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmissionlines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona ...
Electric currents induced due to 60 Hz magnetic fields in a human body placed in a close proximity of various high voltage transmissionlines are computed. A realistic model of the human body from the anatomical and electrical point of view with resolution of 1.3 cm for the body and 0.665 cm for the head is used. The computations are performed using the impedance method. Three representative configurations of high voltage transmissionlines, namely 500 kV, 138 kV and 25 kV are analyzed. The results indicate that the maximum current densities of the order of 0.2 {micro}A/cm{sup 2} can be induced in a lineman working on a 500 kV line (0.5 m away from closest conductors). A good correlation can be seen between the computed magnetic field in the location of the human body and the induced current densities. The induced currents computed here and estimated from measured magnetic fields in ...
This document presented the results of a full-scale pile load tests conducted on helix pile foundations supporting power transmission towers in northern Manitoba. The site conditions were described along with pile installation and the performance of the foundations. The pile load tests were carried out in 2 different soil conditions, notably soft to firm clays and stiff high plastic clays with silt varves. The performance of the helix pile foundations were examined under axial compressive and axial tension (uplift) loading conditions. The results of the compressive load tests were presented in the form of load settlement curves while the results of the uplift load tests were presented in the form of load displacement curves. Both types of load tests in soft or stiff clays showed the suitability of helical pile foundations for power transmissionlines in northern Manitoba. The cylindrical shear failure mechanism controlled ...
The application of HVDC system to the trunk power supply system requires the transmission of DC power as much as possible to improve the stability of the whole AC/DC system. To meet this requirement, continued pulse system, which keeps sending a DC current even when an AC voltage lowers remarkably, has been used. The stability is much more improved by adding damping control which modulates converter active and/or reactive power. In order to make full use of such control effects, it is important that the HVDC system maintains stable operation during faults and reclosing of the AC system. In particular, it is necessary to prevent a repetitive commutation failure following the unbalanced AC transmissionline faults. In this paper, the cause of the repetitive commutation failure is discussed by using the AC-DC power system simulator developed by CRIEPI. Based on the analytical result, a stabilization control scheme with ...
The author says ''barehand'' methods, where specially trained utility workers are called in conductive suits to equalize voltage over their bodies, to maintain high-voltage transmissionlines are on the rise. Utilities are building lines at higher voltages and selling more power to other utilities, making it highly inconvenient to take the lines out of service. However, some unions view the barehand work with less than enthusiasm. Touching lines energized at hundreds of thousands of volts demands flawless equipment and rigid work procedures followed to the letter. Some local unions contend that adequate safety procedures and training, and appropriate penalties for workplace negligence, should be in place before utilities may do barehand work. The author discusses some of the methods of barehand work and the equipment used, i.e. steel-mesh lineman's suit, bucket truck's boom, ...
The power industry is moving toward the use of high-voltage transmissionlines on tall, flexible towers. These towers are designed for heavier loadings than were previous towers, but the secondary effects of tower displacement tend to be ignored in the present day tower analysis. This paper examines the secondary effects from the large displacement of flexible towers, reviews the secondary stresses arising from joint rigidity and member continuity, and examines the reliability of tower strength predicted by the ASCE design guidelines. More realistic tower test acceptance criteria and a more reliable tower design methodology are suggested.
This report presents information obtained during five different studies of field effects from high voltage transmissionlines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmissionlines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air ...
Studies on the effects of electromagnetic fields (EMF)on human health have been conducted for more than 20 years. None have categorically established or eliminated any connection between EMF and adverse health effects. Nonetheless, 96% of the risk managers working in the utility sector view EMF as an over-riding concern. Public concern over EMF has erupted into legal, as well as regulatory, actions. To date, some utilities have had lawsuits brought against them by customers who claim they developed cancer as a result of nearby high-voltage transmissionlines. What`s more, a small handfull of cities have adopted ordinances that specifically limit where and how utilities handle the placement of their transmissionlines.
Considers fundamental problems involved in the precise location of faults on high-voltage transmissionlines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmissionline. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.
The analysis of transmissionline faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmissionline faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.
Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmissionlines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable sources can be integrated into existing ...
Recognizing that a high percentage of transmission-line faults are single-phase to earth and temporary in nature, provides the impetus for considering single-pole switching as a means to enhance the reliability of EHV transmission systems. The effectiveness of single-pole switching schemes is largely determined by the speed with which the secondary arcs extinguish, and hence allow system restoration. Simulation techniques that enable better prediction of the faulted-system response are of obvious importance to the design and assessment of the various single-pole switching scheme applications. In this thesis, digital methods are developed to enable the faulted response of EHV systems to be simulated for a variety of different single-pole switching schemes. These include conventional single-pole switching, the hybrid method of autoreclosure, the neutral switched reactor, and the High Speed Grounding Switch implementations. The work is of ...
A generalized approach to the analysis of the effects of transmissionline faults on natural gas transmission pipelines has been developed and is presented in this report. A state of the art user-friendly computational tool has been developed and verified for the analysis of interference between electrical power lines and nearby buried or above-ground pipelines. This computer program, ECCAPP, is distinguished by its ability to model and analyze accurately complex, realistic interactions between pipelines and power lines, using easily obtained input data. The final report consists of three volumes. An independent fourth volume was also developed to simplify the installation of the ECCAPP software. This report, volume 1, contains the theory upon which the ECCAPP computer program is based. A parametric analysis and graphical charts have been formulated using ECCAPP to permit estimates ...
There are many sources of population exposures to power-frequency (50/60 Hz) electric and magnetic fields including household appliances and wiring, neighborhood distribution circuits, and high-voltage transmissionlines. Bioeffects studies were unable to demonstrate that exposures to power-frequency fields can affect public health. Researcher have likewise been unable to show that the health effects of such exposures are negligible. State and federal regulatory agencies are, therefore, grappling with questions of whether and how to regulate the sitting or design of new extra high-voltage transmissionlines so as to control the ground-level fields to which people are exposed. The purpose of this dissertation is to illuminate some of the exposure-related aspects of these question. A taxonomy of the relationship between field encounter and effect is developed to clarify the meaning of terms such as ...
In recent years, there has been a significant increase in concern over the health and safety aspects of high voltage transmissionlines (HVTL). The majority of research has focused on effects directly or indirectly involved with the central nervous system, including physiological, ultrastructural, and biochemical alterations, changes in blood composition, behaviour, reproduction, and development. Several recent epidemiological reports have presented preliminary data suggesting an increase in the incidence of cancer among children and adults exposed to magnetic fields through living close to various types of electrical power lines or devices. With the increase in environmental concerns there has been a concomitant consideration of biological effects and health implications related to presently existing HVTL and those planned in the future. It was concluded that the electric and magnetic field strengths and the electrical ...
The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ``wings`` that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least ...
The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ''wings'' that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least ...
This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.
This paper reports on the results of experiments into efficient higher-order anti-Stokes Raman conversion of tunable short-pulse XeCl laser radiation. The maximum output energy of the pumping laser, in which the radiation of a frequency-doubled dye laser is amplified by two XeCl laser amplifiers, is 55 mJ with a pulse duration of 1 ns FWHM. Using hydrogen gas as a Raman medium, a series of anti-Stokes lines up to the 12th order (121.5 nm) is generated in the vacuum ultraviolet (VUV) region. 16 references.
On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an ...
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
This paper describes a Honshu-Shikoku linking transmission cable building plan and its technical features. The Chugoku District and the Shikoku District are supplied with power currently by the Chugoku-Shikoku trunk line of 220,000 volts. To cope with the anticipated power shortage, a plan was established to install power cables for 500,000 volts on the Honshu-Shikoku connecting bridge. The plan calls far an installation length of 127.4 km and a transmission capacity of 1.2 million kW per line. The cable installation on the Seto Bridge was completed already, the construction is now in the peak period for building steel towers on the land sections, and laying overhead cables and underground cables. Commencement of the operation is scheduled 1994 on one liner, and 2000 on two lines. The technical features include the Japan's first large-capacity, long-distance underground ...
Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available
Modern microprocessor-based relays for the protection of the various power system components such as generators, transformers, feeders, and high voltage transmissionlines are becoming more sophisticated as increasingly more complex functions and capabilities can be included in the microprocessor. With this increasing complexity, and the increasing complexity of the power system itself, there is even more value in testing the suitability of relaying equipment for the intended applications. This paper reviews the testing philosophy, experience, and capabilities developed at Ontario Hydro over more than 25 years of testing protective relays.
The interest in efficient solar collector design has stimulated investigation of two-dimensional (trough-like) cavity structures. A novel principle for designing cavity enclosures is described. The present method maintains high transmission albeit at the expense of some concentration in the presence of gaps as large as the radius between reflector and receiver. The new method can be applied to advantage to nonimaging concentrator design as well as to line focus concentrators.
A new simple analytical approach is developed for optimum size of series capacitor compensation. The method gives quick and accurate results. Need for formulating a big quadratic or voluminous fourth order equation and the solution of the above with the aid of computers is avoided. Graphical plotting also is not required. 8 refs.
Possible causes of forest damage are discussed. Mapping of affected areas by various workers resulted in dissimilar pictures. Release of radioactive rare gases, aerosols, tritium and carbon-14 seems unlikely to have a significant influence on forest damage. Influence of radioactive fallout, ozone formation by high-voltage transmissionlines and synergistic effects is also found to be negligible.
Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.
With reference to three hypotheses on the causes of forest decline, the manifold uses of forest decline surveys are demonstrated. Hypothesis no. 1: Forest disease from high-voltage transmissionlines; hypothesis no. 2: Forest disease as the consequence of damage from micorrhizas; hypothesis no. 3: Radioactivity as the cause of the increased incidence of forest disease. (orig./MG)
... and pathogen transmission. Because the ultimate object of stem cell research is cell-based clinical therapy, hES cells should ... 4%) Supported by grants (SC12021 and SC11012) from Stem Cell Research...
This apper discusses whether health risks are associated with exposure to electromagnetic fields that exist beneath high-voltage transmissionlines. This is a question receiving increasing attention as the electric utility industry prepares to supply its customers with increased amounts of electric power. 26 refs.
Efforts during the past year by the US Department of Energy and the Electric Power Research Institute-funded laboratories to investigate the biological effects from electric fields are described in resume form. Investigations generally have been summarized with objectives, accomplishments of the past year, and some indication of projected studies.
When a bipolar HVDC transmission system is operating monopolar using the earth as a return path, it is often desired to divert the return current from the earth to the line from the unused pole. To do so requires either that the system be shut down temporarily or that a dc circuit breaker be used. This paper describes the development of such a new dc circuit breaker, and its application on the Pacific Intertie as a Metallic Return Transfer Breaker (MRTB).
We propose a novel scheme for scalable solid state quantum computing, where superconducting microwave transmissionline resonators (cavities) are arranged in a two-dimensional grid on the surface of a chip, coupling to superconducting qubits (charge or flux) at the intersections. We analyze how tasks of quantum information processing can be implemented in such a topology, including efficient two-qubit gates between any two qubits on the grid and elements of fault-tolerant computation.
In the Hokuriku area along the coast of the Japan Sea, thunderstorms often occurred not only in summer but also in winter, and this resulted in the shutdown of electricity supply or damage of equipment. This study was concerning the observation of the lightning channels in the Hokuriku area through a year by many still cameras equipped with liquid-crystal shutters. The following conclusions were obtained: Among 165 lightning incidents photographed during 2 years, there included 172 incidents of the falling thunderstorms and 23 incidents of simultaneously falling thunderstorms at multi-area. In the case of winter, frequency to occur simultaneously falling thunderstorms at multi-area was higher and the upward falling thunderstorms were more. There was a tendency that the duration time of the lightning current in winter was longer than in summer. In winter, frequency to occur the upward falling thunderstorms was higher, about 61% of the upward falling thunderstorms rose from the ...
The efficiency of dendrosome (a gene porter) was assessed in transferring recombinant human rotavirus VP2 cDNA into A549, a human lung cell line. After gene transferring, transmission electron microscopy showed core-like particles (CLPs) formation in the transfected cells both with dendrosome and lipofectamine porters. In addition, western blotting analysis showed that the expression of VP2 gene was almost equal in the dendrosome and lipofectamine-transfected cells. Also, the cytotoxicity studies revealed that dendrosome had a lower cytotoxicity than lipofectamine. Therefore, our study may introduce dendrosome as a possible carrier for gene transferring into the human lung cell line, especially, for intranasally administration of DNA vaccines.
Manitoba Hydro's Ice Storm Management Program to reduce ice damage to overhead power lines in the voltage range of 8 kV to 115 kV is described. Overhead power lines are de-iced either by AC ice melting, which involves placing a three-phase short at a calculated point, or ice rolling, which is a process of mechanically stripping ice from conductors. Direct current heating and underground distribution systems are also accepted prevention measures. Advantages and disadvantages of each of these methods of de-icing are reviewed. Material for this paper has been extracted from a workshop manual prepared for the 1993 and 1998 Ice Storm Management workshops organized by Manitoba Hydro through the Canadian Electrical Association. 1 ref.
The growth of thin Pd[sub 2]Si films on Si(111) surfaces is studied using [ital in] [ital situ] transmission electron microscope under ultrahigh vacuum conditions. No immediate reaction of deposited Pd with Si is observed at room temperature. At [similar to]200 [degree]C, uniform Pd[sub 2]Si films can be formed. The thin Pd[sub 2]Si films are found to grow into strained islands at elevated temperatures. Interfacial misfit dislocations associated with interfacial steps propagate across the strained islands, causing the islands to grow layer-by-layer at the interface. The strain fields associated with the misfit dislocations are believed to be responsible for this behavior.
Full text: Institute for Nuclear Research, Pitesti-Mioveni, Romania in direct cooperation with the National Institute for Laser, Plasma and Radiation Physics, Magurele, Bucharest studied and prepared for coating more than 1000 tiles made of Inconel with 7-9 #mu#m of beryllium for nuclear fusion applications at JET, Culham, UK. The principles of manufacturing processes using thermal evaporation and plasma ignited in pure metal vapors as well as by Thermionic Vacuum Arc (TVA) method and the properties of the Ni and Be coatings are presented. The prepared beryllium layers were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and atomic force microscopy. (authors)
Magnetic fields can be compensated by opposing fields. This principle can be applied for reducing the magnetic fields emanating from high-voltage transmissionlines or found in residential or commercial buildings. The article shows a number of concrete options for reducing magnetic fields in the vicinity of high-voltage lines through appropriate conductor configuration on the one hand, and a novel method using Helmholtz coils for compensating those fields in buildings. (orig.) [Deutsch] Magnetische Felder koennen durch Gegenfelder kompensiert werden. Dieses Prinzip laesst sich sowohl auf Hochspannungsleitungen als auch auf Wohn- und Arbeitsraeume uebertragen. Der Artikel zeigt konkrete Moeglichkeiten, wie einerseits Magnetfelder von Hochspannungsleitungen durch eine geeignete Konfiguration der Leiter reduziert werden koennen, und beschreibt andererseits eine neue Methode zur Reduktion solcher Felder in Wohn- und ...
MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year the full 242 operational days were utilized. Beam line test and evaluation consumed 21 days with eight MATRIX groups combining to use 170 days. General user demand for use of the beam line continues to be strong and three groups were provided 51 operating days. Research production has been growing as NSLS and the ...
As a central supervision authority the National Electrical Safety Board (Elsaekerhetsverket) has the main responsibility for the safety of high voltage power lines and other power electric equipment. It is therefore also responsible for questions concerning the effects of power frequency magnetic fields on the environment. According to the rules it is not allowed to draw overhead power lines with a voltage exceeding 1000 V above buildings. Their minimum distance to buildings must not be below 5 m. For regions comprised by rural development plans the directions prescribe a minimum distance of 10 m between buildings and high voltage transmissionlines with a voltage of 55 kV or more. The publication of two large epidemiological studies about exposure to magnetic fields and cancer in Sweden in autumn 1992 has brought magnetic fields problems to general notice again. A statement on health risks form ...
The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasma obtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma obtained 10 kA by using only outer PF coils and single ST was generated at the lower area (z=-0.3 - -1.0[m]) close to a washer gun. This result ...
The Heard Island Feasibility Test (HIFT) demonstrated that coded acoustic signals could be detected at ranges up to 18,000 km with currently available source technology. This paper describes one component of the HIFT where a large aperture vertical line array was deployed to record the signals transmitted from Heard Island. We have performed four analysis Of the VLA receptions, of the Heard Island signals. All four suggest the presence of higher order modes. The frequency- vertical wavenumber analysis and the modal beamforming indicate that mode 3 has the highest amplitude while the modal fitting suggests that made 5--6 are largest. It is difficult to resolve the differences since the SNR at the VLA, nearly 18,000 km with a transmission loss of around 145 dB, is quite low. Individual arrivals could not be distinguished because of the long integration time necessitated by the low SNR.
This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.
The object of this program was to design and build a self-contained system for remote monitoring of the atmosphere in mines. The system developed uses the mine pager phone line as the primary communication channel and also has the capability of using 208 Hz in the ELF band for wireless transmission through the earth. The depth for through-the-earth transmission is expected to be about 80 to 90 meters in high conductivity soil and is limited by the noise level in the ELF band-pass filters. The underground components of the TEM System are energized by mine power through a battery charger-storage battery power supply. In the event of mine power failure the battery capacity is more than sufficient for 1 week's operation with interrogations every 4 hours.
This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.
A generalized approach to the analysis of the effects of transmissionline faults on natural gas transmission pipelines has been developed and is presented in this report. A state of the art user-friendly computational tool has been developed and verified for the analysis of interference between electrical power lines and nearby buried or above-ground pipelines. This computer program, ECCAPP, is distinguished by its ability to model and analyze accurately complex, realistic interactions between pipelines and power lines, using easily obtained input data. The final report consists of three volumes. An independent fourth volume was also developed to simplify the installation of the ECCAPP software. Volume 1 contains the theory upon which the ECCAPP computer program is based. A parametric analysis and graphical charts have been formulated using ECCAPP to permit estimates to be made in ...
The problem of electrical parameters identification in complex systems, and in particular in electric railway traction systems, is considered. Parameters are determined by an indirect approach: only the terminal variables (voltages and currents and, impedance and admittance, which can be readily calculated) are measured and the per-unit-length electrical parameters are determined using a multiconductor transmissionline model of the track section under test. It will be shown that some parameters cannot be measured directly, that they are not constant with frequency and that they may depend on other external conditions. An indirect method for parameters identification is proposed through an adaptive algorithm (AA), so that the calculated terminal variables match the measured ones. The AA is...
An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).
In the analysis of power systems security, recently a new concern related to possible malicious attacks caught much attention. Coordination among different transmission system operators (TSO) in an interconnected power system to counteract such attacks has become an important problem. This paper presents a general framework for describing the physical, cyber and decision-making aspects of the problem and their interrelations; within this framework, an analytic tool for the assessment of information impacts in handling on-line security after a malicious attack is proposed and discussed. The model is based on the socially rational multi-agent systems and the equilibrium of a fictitious play is considered to analyze the impacts of various levels of information available to the interconnected system operators on the outcomes of the decision-making process under attack. A 34-buses test system, with 3 systems interconnected by ...
Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmissionlines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.
Free Topology Network technology provides cost reduction benefits as well as flexibility in safeguards applications. Power line communications technologies have proven viability for transmission and reception of safeguards data, including surveillance photographs, the source of the largest data files. In the future, enhancements will be made to the technology that should boost both performance and flexibility. Work is already underway to achieve higher data rates over power line communications eventually, it should be possible to reach data rates of one million bits per second or higher. Also, the use of technologies such as Novell Embedded Systems Technology (NEST) and Echelon LON technology will allow a greater number of safeguards technologies to become resident on the Free Topology Safeguards Network.
Free Topology Network technology provides cost reduction benefits as well as flexibility in safeguards applications. Power line communications technologies have proven viability for transmission and reception of safeguards data, including surveillance photographs, the source of the largest data files. In the future, enhancements will be made to the technology that should boost both performance and flexibility. Work is already underway to achieve higher data rates over power line communications eventually, it should be possible to reach data rates of one million bits per second or higher. Also, the use of technologies such as Novell Embedded Systems Technology (NEST) and Echelon LON technology will allow a greater number of safeguards technologies to become resident on the Free Topology Safeguards Network.
Ag, Cu, and Ni metallizations were inkjet printed with near vacuum deposition quality. The approach developed can be easily extended to other conductors such as Pt, Pd, Au, etc. Thick highly conducting lines of Ag and Cu demonstrating good adhesion to glass, Si, and printed circuit board (PCB) have been printed at 100-200 deg C in air and N2 respectively. Ag grids were inkjet-printed on Si solar cells and fired through the silicon nitride AR layer at 850 deg C, resulting in 8% cells. Next generation inks, including an ink that etches silicon nitride, have now been developed. Multi-layer inkjet printing of the etching ink followed by Ag ink produced contacts under milder conditions and gave solar cells with efficiencies as high as 12%.
Abstract Microbiological quality and biophenol content evolution was studied in minimally processed Thassos cv table olives by hot air dehydration under mild conditions (40C, 24-h, aw-=-0.893) and storage under characteristic packaging conditions (vacuum, 100% N2 and air) at 4 and 20C over a period of 180 days. No salt was used in the production line or packaging. The undesirable microorganisms (Enterobacteriaceae, Staphylococcus aureus, Bacillus, Clostridium) were undetectable until the end of the storage period. Also, modified atmospheres prevented fungal growth at both temperatures apart from the samples stored in air, in which Penicillium and Aspergillus spp. were identified. At 20C, a coexistence of mesophilic bacteria and yeasts occurred. At 4C, yeasts were the predominant microflora...
In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to deriv...
An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.
BC Hydro`s approach to improve the performance of its underground transmissionlines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the cable line to within ...
In the 150 kV power system of the Dutch energy utility MEGA Limburg cross-country faults have caused problems in the protection of high voltage transmissionlines. A cross-country fault is the simultaneous presence of two single-phase earth connections in different phases and places within the grid. These cross-country faults can lead to the incorrect operation of a number of distance relays, which could result in the faulty disconnection of high voltage transmissionlines. To gain an insight into these problems, the transient phenomenon in the power system during cross-country faults were studied. For this purpose, the simulation program EMTP (ElectroMagnetic Transients Program) has been used. Simulation models of the 150 kV power system and the measuring system of a distance relay were developed within EMTP. 7 figs., 1 ill.
More than 30 environmental concerns were analyzed for the transportation of coal by rail, roads (trucks), high voltage transmissionlines (that is, from mine-mouth generating plants to distribution networks), coal slurry pipelines, and barges. The following criteria were used to identify these problems: (1) real physical environmetal impacts for which control technologies must be developed, or regulation made effective where control technologies presently exist; (2) the level of impact is uncertain, although the potential impact may be moderate to high; (3) the concerns identified by the first two criteria are specific to or exacerbated by coal transportation. Generic transportation problems are not included. The significant environmental problems identified as a result of this study are: (1) rail transport - community traffic disruption and human health, safety, and habitat destruction; (2) coal haul roads - road degradation, traffic ...
The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmissionlines, households), and magnetic alternating fields (high-voltage transmissionlines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener niederfrequenter ...
Large capacity adjustable speed machines (ASMs) at pumped storage power station have been put into full operation and the operating characteristics of ASM have been highly evaluated from the view point of power system operation. The output power (input power) of ASM can be controlled very quickly by applying a vector control scheme to the excitation control. This quick responsive feature of ASM can make it possible to improve the stability of the neighbor sub-power system. For improvement of transient stability, the output power of ASM is reduced very quickly in order to control the acceleration of neighbor generators during and after transmissionline faults. For improvement of dynamic stability, the output power of ASM is modulated in accordance with the stabilizing signals detected from the swing of generator rotor or the power flow fluctuation on the transmissionline. This paper describes the ...
Independent power producers (IPPs) have had open access to existing power systems ever since the electric power industry was restructured and deregulated. IPPs are small-scale, distributed, and independently operated. Introducing an IPP to the power system can be beneficial to the existing power system because it can increase the security margin or reduce production cost and environmental pollution. The disadvantage is that some IPPs are not subject to dispatch control, consequently, they may reduce the network security. Often IPPs use co-generation, small-scale hydro, even fuel cells or other types of renewable energy sources. An evaluation of IPPs impact on an existing utility power system was determined in a modified IEEE 14 bus system. The total generating cost, environmental impact, transmissionline margin, voltage profile, network congestion, security and other power quality measures were evaluated. It was concluded that on balance, an ...
The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the alternator rectifier type and the PSS control utilizes shaft speed as an input signal. The units must ...
A field study was conducted in Ontario to evaluate the suitability of grouted piles for transmission tower foundations. The grouted piles were assessed in terms of the installation procedure and its foundation performance subjected to uplift loads. Two types of grouted piles, the H-pile and the pipe-pile, were evaluated and compared with conventional ungrouted H-pile foundations. Difficult soil conditions were encountered consisting of a deep deposit of loose to compact sand with a high water table. Both the grouted pipe-pile and the grouted H-pile developed uplift capacities more than double that of the conventional H-pile with the same embedment length at the test site. The grouted H-pile is recommended as a viable transmissionline foundation in weak soils due to the significant improvement in its foundation performance, with minor modifications to the construction procedure. 3 refs., 17 figs., 12 tabs.
The studies undertaken by the B.C. Hydro company at the Canada showed that the existing system of hydroelectric power plants and transport cables will not be able to satisfy the increasing energy demand on the Vancouver island after 1985, and that the best solution will be the installation of a 525 kV transfer system from the continent. THe STK participated to the development and the immersion of this new system, the first in the world comprising submarine 525 kV transport parts. This paper presents the planning, the development, the submerging and the installation of two sections of submarine cable.
Small electrical demand supply systems, to serve small communities close to high voltage transmissionlines, have been examined to delineate their technical and economic characteristics. Parameters to measure system performance were outlined. Development of the Brazilian version of the Energy Overhead Ground Wires (EOHGW) system was described. This system has been supplying electricity to Rondonia and Mato Grosso states in central and northern Brazil, Operating experiences with this system were reviewed. 4 refs., 8 tabs.
The RF system for the SuperHILAC injector linac was designed and constructed for minimum system complexity, wide dynamic range, and ease of maintenance. The final amplifier is close coupled to the linac and operates in an efficient semilinear mode, eliminating troublesome transmissionlines, modulators, and high level regulators. The system has been operated at over 250 kW, 23 MHz with good regulation. The low level RF electronics are contained in a single chassis adjacent to the RF control computer, which monitors all important operating parameters. A unique 360/sup 0/ phase and amplitude modular is used for precise control and regulation of the accelerating voltage.
As contamination flashover is in Mexico the second cause of transmissionline faults, the Mexican Electrical Research Institute carried out a project to determine pollution patterns for the Republic of Mexico to be used for the design of external insulation. Results from the project are presented: the modelling, based on the field data of 23 experimental sites, of long term variations of pollution patterns as a function of environmental variables, insulator shape and position, as well as other important field results. 32 refs, 2 figs, 4 tabs
A billet of low-density carbon-bonded carbon fiber (CBCF) composite is machined into a desired attenuator or load element shape (usually tapering). The CBCF composite is used as a free-standing load element or, preferably, brazed to the copper, brass or aluminum components of coaxial transmissionlines or microwave waveguides. A novel braze method was developed for the brazing step. The resulting attenuator and/or load devices are robust, relatively inexpensive, more easily fabricated, and have improved performance over conventional graded-coating loads.
We propose to encode a register of quantum bits in different collective electron spin wave excitations in a solid medium. Coupling to spins is enabled by locating them in the vicinity of a superconducting transmissionline cavity, and making use of their strong collective coupling to the quantized radiation field. The transformation between different spin waves is achieved by applying gradient magnetic fields across the sample, while a Cooper pair box, resonant with the cavity field, may be used to carry out one- and two-qubit gate operations.
We study a quantum computing system using microwave photons in transmissionline resonators on a superconducting chip as qubits. We show that linear optics and other controls necessary for quantum computing can be implemented by coupling to Josephson devices on the same chip. By taking advantage of the strong nonlinearities in Josephson junctions, photonic qubit interactions can be realized. We analyze the gate error rate to demonstrate that our scheme is realistic even for Josephson devices with limited decoherence times. As a conceptually innovative solution based on existing technologies, our scheme provides an integrated and scalable approach to the next key milestone for photonic qubit quantum computing.
This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmissionlines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.
An apparatus is provided for rapidly restarting the flow of coolant through the cold electromagnetic shield of a superconducting rotor following a thermal transient episode. A vortex diode inhibits coolant flow in the undesirable reverse direction and encourages the reestablishment of a normal thermosyphon cooling loop flow quickly following the termination of a thermal transient such as that caused by transmissionline faults. The present invention requires no moving parts and may therefore be permanently sealed in the superconducting rotor without risk of costly repair efforts caused by components failure.
The booklet presents general information and practical hints for the task of acquiring and evaluating the data describing investments and other expenditure and activities for pollution abatement measures taken by electric utilities. The information is intended as an aid for establishing standard criteria for assignment and evaluation, and for comparison and classification of pollution abatement measures. As a line of orientation, a catalogue of pollution control measures is given, arranged into the following sections: Fossil-fueled power plants; nuclear power plants (BWR and PWR); hydroelectric power plants; power transmission and distribution. (HSCH)
Data on various aspects of the electric power industry in Germany is presented in this article. A map of high voltage transmissionlines used by the public utilities is included, which indicates the fuel used at each power station. Data on power generated by fuel used from 1991 to 1996 is given, and additional or new capacity for 1995 to 1999 is also noted. Other tables detail capital investment in public utilities energy input by fuel source, power capacity by utility or private power stations by energy source, utility ownership and electricity demand by consumer. (UK)
The underlying theory and model of capacitive voltage substations and its associated problems are described. This system is intended to supply electricity to rural communities directly from high-voltage transmissionlines. This technique leads to important cost reductions when compared with conventional alternatives. However, in several transient cases, some problems such as ferroresonance and overvoltages could occur in these substations. Using a developed capacitive substation model these transient cases are simulated. A suitable filter is designed to damp overvoltages clue to ferroresonance. Analytical aspects of filter design are presented and some computer simulation tests are provided to highlight the usefulness of the proposed filter. (author)
The report traces the documented incidences of brittle fracture in composite suspension insulators for use on high voltage transmissionlines, and presents the subsequent investigations. It describes the part played by electrical activity, stress corrosion and humidity, and compares similar failures that have taken place in electric traction insulators. It then goes on to review related work on the humidity effects, stress corrosion, fatigue and partial discharges in glass fiber reinforced plastics in general. The final section summarizes the present understanding of the problem and the various measures taken by different manufactures to avoid it in the future. The need for acceptance criteria in this respect is outlined.
K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.
Dosimetry is evaluated for live-line workers exposed to 50 Hz non-uniform magnetic fields from typical high-voltage transmissionlines in the United Kingdom. The configurations involve twin-, triple- and quadruple-conductor transmissionline bundles. Scenarios include three worker postures for the twin and triple bundles, and four postures for the quadruple bundle. The postures are selected to simulate worst case scenarios representative of work practices and result in highest values of dosimetric measures in critical organs. Only single-phase bundles are considered, as adjacent bundles of differing phase result only in a small reduction of the dosimetric measures. Reported data include various measures of the electric field and current density induced in tissues, as well as of the current density averaged over 1 cm"2 areas normal to the current flow. A value of this latter quantity ...
Because of questions regarding current density and inductance estimates of the Atlas oil transmissionline in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for design 3 current density is 17MA/m. Maximum current density on the hot plates is 20MA/m for all 3 designs. ...
This paper reports that more than 800 miles of pipeline will come into service on the U.K. continental shelf during 1993, surpassing by 75% the previous record set in 1977. About 3,500 miles of pipeline is in place. Commissioning of the Miller natural gas pipeline and Scottish Area Gas Evacuation (SAGE) network this year and start-up of the Central Area Transmission System (CATS) next year will bring more than 600 miles of pipeline into use during 1993. The projects are part of a recent development boom in the central North Sea. In a review of U.K. offshore pipeline, analyst County Natwest Woodmac reported that projects totaling about 1,250 miles of pipeline have been sanctioned but are not yet operating. Two thirds of this total is gas pipeline, while 60s made up of main lines from shore to platform. County Natwest says that in most cases spur lines will be used to connect new fields with existing infrastructure. The ...
Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmissionlines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF ...
Location of transmissionline faults are traditionally estimated by measuring the apparent impedance from a line terminal to the fault and converting the reactive component of the impedance to line length. None of the methods proposed to date address adequately the problems of fault location on distribution systems that have single or multiphase laterals and/or tapped loads. The research for this dissertation resulted in the development of a technique that estimates the location of a shunt fault on a radial distribution system that has several single and/or multiphase laterals. The technique takes into account load taps and non-homogeneity of the system, and has been tested for its ability to handle single-phase-to-ground, two-phase-to-ground, phase-to-phase and balanced three-phase faults. Computer simulations indicate that the technique is more accurate than the reactive component method. Results from ...
This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It was concluded that a Multilayer Vacuum ...
Modeling free-electron laser (FEL) oscillators requires calculation of both the light-beam interaction within the undulator and the light propagation outside the undulator. We have developed a paraxial optical propagation code that can be combined with various existing models of gain media, for example, Genesis 1.3 for FELs, to model oscillators with full paraxial wave propagation within the resonator. A flexible scripting interface is used both to describe the optical resonator and to control the codes for propagation and amplification. To illustrate its capabilities, we numerically investigate two significantly different FEL oscillators: the free-electron laser for infrared experiments (FELIX) system and the vacuum-ultraviolet (VUV)-FEL oscillator of the proposed high-gain fourth generation light source. For the FELIX system, we find that diffraction losses are a considerable part of the single-pass cavity loss (at a wavelength of 40 #mu#m). We also demonstrate ...
Vacuum insulation panels (VIP) offer excellent thermal resistance properties that can enhance the energy efficiency of insulating systems, save space and contribute to energy consumption reductions. However, VIPs are not used much in Canada, and new commitments to carbon dioxide reductions has created the need to study the prospect of using VIPs in various components of a building envelope. For that reason, assessment methods for the applicability and sustainability of VIPs for use in building envelope construction were developed. There are practical aspects regarding the long-term performance and application of VIPs in building construction. Air molecules and water molecules can permeate through the foil and seams of the VIPs, causing a reduction in thermal resistance. This paper addresses some of the test methods that may accelerate long term changes in thermal resistance. Results were presented from tests using elevated pressure, relative humidity and ...
Hamiltonian light-front dynamics of quantum fields may provide a useful approach to systematic nonperturbative approximations to quantum field theories. The authors investigate inequivalent Hilbert-space representations of the light-front field algebra in which the stability group of the light front is implemented by unitary transformations. The Hilbert space representation of states is generated by the operator algebra from the vacuum state. There is a large class of vacuum states besides the Fock vacuum which meets all the invariance requirements. The light-front Hamiltonian must annihilate the vacuum and have a positive spectrum. Relations are exhibited of the Hamiltonian to the nontrivial vacuum structure. 30 refs.
It is shown that vacuum instabilities possibly arising because of tachyons do not contradict any experimental evidence, and therefore that no objection against tachyon existence can be found even on this ground. (Auth.).
This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.
A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer ...
Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding ...
The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmissionlines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, ...
Full text.This paper is to investigate the potentials and possibilities of electrical generation via wind turbine. Special attention is directed to the interpretation of wind generation characteristics and parameters found in Lebanon and linking the electrical energy to the Lebanese slectric grid. Although much of the wind energy research is very well established and boomed globally (USA, Europe, India and China), in Lebanon is never used. At a time when climate scientists are increasingly concerned about carbon dioxide emissions from coal and diesel plants, and the nuclear industry is drying, the significance of a major new source os electricity is clear. there are many motives and feasibility criteria for qind power generation in Lebanon. They include the need for increasing the Lebanese electrical capacity, reducing air pollution, alternative energy sources and prices and availability of oil. The work will include literature survey on current wind energy development and application. ...
For over 50 years, the Bonneville Power Administration (BPA) has evolved to supply electric power to more than 170 customer utilities and direct service industries across 14,800 miles of high voltage transmissionlines. BPA's Office of Engineering provides the planning, development, and engineering for the required expansion, upgrade, and replacement of the transmission system. The purpose of this 10-Year Plan is to present strategies to maintain a reliable energy delivery system within changing public, business, technological, and environmental climates. The issues and trends discussed in this document and our strategies for addressing them provide the background for the Office of Engineering programs and projects. With a budget in the hundreds of millions annually and increasing public concern, we welcome the opportunity to communicate with our customers. In addition to the factors, trends and issues described in ...
For over 50 years, the Bonneville Power Administration (BPA) has evolved to supply electric power to more than 170 customer utilities and direct service industries across 14,800 miles of high voltage transmissionlines. BPA`s Office of Engineering provides the planning, development, and engineering for the required expansion, upgrade, and replacement of the transmission system. The purpose of this 10-Year Plan is to present strategies to maintain a reliable energy delivery system within changing public, business, technological, and environmental climates. The issues and trends discussed in this document and our strategies for addressing them provide the background for the Office of Engineering programs and projects. With a budget in the hundreds of millions annually and increasing public concern, we welcome the opportunity to communicate with our customers. In addition to the factors, trends and issues described in this ...
The numerous challenges facing the North American electric utility industry were discussed. In addition to competition, electric utilities are faced with low demand growth, public pressure to avoid adding transmission and distribution capacity, and strict environmental requirements. In view of these developments, large central generation additions that have been industry norm until recently, do not always make economic sense in the current environment. Instead, smaller, distributed additions to generating capacity is becoming the new norm. Small-scale on-site generating capacity has the added advantage of reducing the need for expensive high-voltage transmissionlines. The Ballard generation system described here is a modular, efficient fuel cell-based solution to implementing distributed power concepts. The system is natural gas fueled, with low noise, vibration and emissions. Apart from its other advantages, it provides ...
For large transmission steel towers to be built in a mountainous area, caisson type pile foundations are often applied. The works for construction of this kind of foundation are manned operations such as drilling, arranging reinforcements, concrete laying, etc. in a narrow vertical pit which is 3m in diameter and about 20m in depth, but securing labour force of good quality for such works becomes increasingly difficult. In order to cope with the above situation and achieve reduction of costs, shortening of construction period, improvement of safety, saving of manpower, etc. a power supply company and construction companies have developed jointly a method of unmanned construction in a caisson type pile foundation pit. This method consists of the use of a caisson type pile full size excavator (this consists of an excavator proper, a vacuum soil discharging device, a monitor/controller, a load crane and a reaction pad, and performs continuously ...
This Final Environmental Impact Statement and Environmental Impact Report (Final EIS/EIR) has been prepared to meet the requirements of the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). The Proposed Action includes the construction, operation, and decommissioning of a 48 megawatt (gross) geothermal power plant with ancillary facilities (10-12 production well pads and 3-5 injection well pads, production and injection pipelines), access roads, and a 230-kilovolt (kV) transmissionline in the Modoc National Forest in Siskiyou County, California. Alternative locations for the power plant site within a reasonable distance of the middle of the wellfield were determined to be technically feasible. Three power plant site alternatives are evaluated in the Final EIS/EIR.
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmissionlines as well as computer work-places. (orig.).
Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmissionlines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.
A flowing carbon dioxide laser was operated at low pressures up to 4 torr. Excitation of the laser was provided using various combinations of direct current (DC), pulsed microwave, and continuous wave (CW) microwave excitation. The microwaves were in the 2.45 GHz band and were coupled into the gas using a slow-wave interdigital transmissionline. Laser output of 25 milliwatts (mw) was achieved using a DC discharge only. A combination of a DC discharge and pulsed microwaves doubled the output and resulted in some modulation. Changing the laser gas mixture and pulsed microwave field characteristics allowed some flexibility in the modulation. Lasing was not achieved with excitation from the CW microwaves alone due to the formation of localized discharges. Using pulsed microwaves to sustain the discharge and CW microwaves to pump the laser, a quasi-CW output of 55 mw was achieved.
A solid layer artificial pollution test was carried out to study the pollution performance of a new type of hybrid station post insulator used in suspension and tensile high voltage transmissionlines. The structure of the separated silicone rubber shed and porcelain core hybrid insulator was shown. The new insulator showed excellent pollution performance under both HVAC and HVDC conditions. It also exhibited excellent aging performance in artificial aging tests. The mechanical strength of the hybrid insulator was also better than normal composite insulators. Another advantage revealed was the fact that separated silicone rubber sheds and porcelain core hybrid post insulators are easier to manufacture than normal porcelain post insulators and other hybrid insulators. 5 refs., 6 tabs., 1 fig.
Various transmissionline fault location algorithms have been proposed in the past depending on measurements available. These methods evince that if a sufficient number of meters are placed in a power network to record the fault measurements, then the fault location can be reliably estimated. A relevant question to ask may be: how many meters are sufficient in order to derive a reliable and unique fault location estimate for a given network? This paper addresses this question by defining and performing the fault location observability analysis. An optimal meter placement scheme is proposed for determining the optimal locations to place meters so as to make the system observable while minimizing the required number of meters to reduce costs. The proposed method is especially useful for powe...
This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.
This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmissionlines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).
This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.
When the transmissionline is very long or the generator is operated at a power factor nearly equal to 1.0, the machine regulated by an automatic voltage regulator (AVR) cannot be operated stably due to poor dynamic stability. To overcome this difficulty, the so called power system stabilizer (PSS) is very useful, in that output power or rotor speed of the generator is used as a feedback signal. The primary obective of the PSS is to damp the swing of the generator as quickly as possible. A method is proposed for designing PSS which yields a given eigenvalue. In the second method, the use of a Heffron-Phillips model is discussed. Next, a detailed procedure for the proposed design method is presented. A generalized method of a PSS design based on Park's equation and matrix operation is proposed.
Canadian-based Anderson Group Company has developed an innovative round baler for harvesting a large variety of woody biomass. The baler was initially developed in 2005 in collaboration with the University Laval and Agriculture and Agri-Food Canada. The third generation BIOBALER{sup TM} is currently built, engineered and commercialized by Anderson. It can produce up to 40 bales/hr in short rotations woody crops such as willow and hybrid poplar. The unit can harvest brushes up to 125 mm in diameter. A standard tractor can pull the BIOBALER in fallow or abandoned land, under power transmissionlines, and between planted trees. The patented BIOBALER includes a mulcher head attachment, a choice of long or short swivel tongue, a fixed chamber and an undercarriage frame.
Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmissionline fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...
Breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the utility`s breakers on the feeding transmissionline. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting a circuit breaker from the failure described above, plus other failures that go unprotected with conventional schemes, this providing total breaker failure protection.
The goals of the program include predicting the impact of proposed new generating facilities, evaluating proposed high voltage transmissionlines, assessing the impact of existing generating facilities, forecasting future demand for electric power, and investigating numerous information gaps through a long-range research program. The Power Plant Assessment Division (PPAD) is responsible for all PSC licensing support, site specific research, and radiological monitoring. The list of reports summarizes information of over 190 technical publications that represent the Program`s formalized research and monitoring efforts over the last five years. Reports are listed in chronological order by topical heading.
Presently no one knows whether electromagnetic fields (EMFs) play a role in human cancer or other ailments, though epidemiological studies over the years have suggested that possibility. A study by the Electric Power Research Institute attempted to quantify everything it could about the magnetic environment of a home, identifying not only major sources of magnetic fields, but also their frequencies, strengths, and how they fall off with distance. Sources of a homes magnetic environment include appliances, overhead powerlines, and grounding connections to metallic water pipes. Fields will vary over time, depending on how much current is passing through the electrically conductive sources. Additional contributors to a home's magnetic background may include unusual wiring in the walls, underground power lines, and near-by high voltage transmissionlines. This paper summarizes the study results, indicating weak, persistant EMFs ...
The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A ...
We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)
In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility of current-enhanced SASE schemes (ESASE) ...
In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility of current-enhanced SASE schemes (ESASE) ...
We present an approach for fabrication of intentionally positioned epitaxial InAs QDs in a micron sized light emitting diode. For site-selective growth, a combination of molecular beam epitaxy (MBE) and focused ion beam (FIB) implantation technology in an all-ultra-high-vacuum (UHV) setup has been employed. Single dot occupancy of almost 55 % on FIB patterned nano-depressions was successfully achieved. Thereafter, carrier injection and subsequent radiative recombination from the positioned InAs/GaAs self-assembled QDs was investigated by embedding these QDs in the intrinsic part of a GaAs-based micron sized p-i-n junction device. Few or single dot are expected to be electrically addressed in these devices. We report results from electroluminescence (EL) measurement which proves the single dot characteristics of our device. The EL spectra consist of sharp emission lines and their dependence on injection current shows linear behavior for exciton ...
Purpose: To enable the use of a vacuum container under a relatively high temperature or a high level radioactive dose. Constitution: Vacuum sealing materials for use in a vacuum container are made of resins such as polyimide and polyamide. The sealing materials are joined to the both surfaces of a plate-like insulator by means of adhesives or sealants, or the sealing materials are joined between two plate-like insulators by means of adhesives or sealants. They are situated within grooves of both of flanges, which are clamped tightly by insulation bolt and nut. Since the vacuum sealing materials are joined to the insulator by means of the adhesives or sealants, the reliability of the vacuum sealing can be improved without impairing the electrical insulation. The resin of the vacuum sealing material can be used for the radiation dose up to 10"8 rad, temperature up ...
The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.
Research highlights: {yields} Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmissionline. {yields} Power system stabilizer was designed based on optimal pole shifting controller. {yields} The system performances was tested through load disturbances at different operating conditions. {yields} The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. {yields} The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for ...
Research highlights: ? Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmissionline. ? Power system stabilizer was designed based on optimal pole shifting controller. ? The system performances was tested through load disturbances at different operating conditions. ? The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. ? The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex ...
Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The #gamma# ray and an electron beam are commonly used in radiation sterilization. The #gamma# ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such ...
Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of heavy ion fusion. The near equivalence of the Cl"- and Cl"++Cl_2"+ current densities reaching the Faraday cup after passage ...
The evolution of "humanized" (i.e., free of animal sourced reagents) and ultimately chemically defined culture systems for human embryo stem cell (hESC) isolation and culture is of importance to improving their efficacy and safety in research and therapeutic applications. This can be achieved by integration of a multitude of individual approaches to replace or eliminate specific animal sourced reagents into a single comprehensive protocol. In the present study our objective was to integrate strategies obviating reliance on some of the most poorly defined and path-critical factors associated with hESC derivation, namely the use of animal immune compliment to isolate embryo inner cell mass, and animal sourced serum products and feeder cells to sustain hESC growth and attachment. As a result we report the derivation of six new hESC lines isolated by outgrowth from whole blastocysts on an extracellular matrix substrate of purified human laminin (Ln) with transitional ...
Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples ...
While underground power transmissionlines have become to use CV cables as the mainstream, existing facilities still use OF cables. Factors of OF cable deterioration include heat cycles during operation and surge intrusion. As a method to diagnose this deterioration in insulation, characteristics tests are performed by collecting insulation oil in a cable connection box. The insulation oil collection work has been done conventionally with the power line stopped to prevent danger from induction voltage. A power uninterruptible oil collection tool was developed recently. The tool consists mainly of an insulator made of epoxy resin, wherein a connection box connector is rotated and loosened by operating an insulating operation rod, with the structure not contacted directly with metallic sheath, so that insulation oil can go through the oil collecting tool and gets collected. Discussions were given on the tool to be capable of ...
A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target vessel shielded with ...
vehicles including the H2-A rocket and the space shuttle. .... The vacuum can's main function is to provide a high vacuum so that the science experiment and its sensors ... EMI-shielded power conversion from the incoming ISS power supply. 4. ...
Investigation of memory effects in air at 0.7 mbar pressure in the presence of vacuum electrical breakdown mechanism has been performed in this paper. The memory effect has been followed using the time delay method.
The possibility of surface modification of high-speed steel cutting tool by means of vacuum-plasma treatment including ion nitriding in gas plasma followed by the deposition of wear resistant (Ti, Al)N coatings in metal-gas plasma of a vacuum arc discharge is studied. The regularities of nitrided layer formation and the structure of these layers under various operation conditions of cutting tool are investigated. Optimum conditions of vacuum-plasma treatment providing the best wear resistance of cutting are determined
The method of an effective potential is used to investigate the possible types of evolution of vacuum shells in the Friedmann-Schwarzschild world. Such shells are assumed to emerge during phase transitions in the early Universe. The possible global geometries are constructed for the Friedmann-Schwarzschild worlds. Approximate solutions to the equation of motion of a vacuum shell have been found. The conditions under which the end result of the evolution of the vacuum shells under consideration is the formation of black holes and wormholes with baby universes inside have been found. The interior of this world can be a closed, flat, or open Friedmann universe.
This paper proposes a technique of moving picture overlapping for view simulation by means of the moving picture processing. The continuous pictures of actual natural view gotten from video and the pictures of building structure made by computer graphics (CG) were overlapped. The CG pictures of building structure model were made considering the camera parameters, such as position and direction of camera. In order to analyze the continuously changing camera parameters, optical flows were determined from the view video. Based on these results, the overlapping video was made, in which the building structure was incorporated into the actual view. Furthermore, the proposed technique of moving picture overlapping was applied to the view simulation of transmissionline tower. Consequently, it was demonstrated that the overlapped moving pictures can provide information which can not be obtained from the still pictures. It was experimentally confirmed ...
Support for raising energy efficiency is reported for the following five areas during 1998-2001: 1. Fuel-based energy systems with the sub-areas: Sustainable production of biofuels, including ash recycling; Cogeneration; and Large scale heat production. 2. Transport with two sub-areas: Internal combustion engines; and Electric drive-lines. 3. Power production/Power technology with the sub-areas: Hydropower; Wind power; Power transmission and distribution; and Photovoltaic solar cells. 4. Industry with the sub-areas: Processes; and Support systems in industry. 5. Buildings with the sub-areas: Heating, cooling and climatic shields; and Components and support systems. In total, 1,800 M SEK (about 180 M USD) was contributed by the Energy Administration during this period. An overview of the projects is presented in this report.
The developed electrical networks in the agricultural regions of the Estonian SSR make it possible to construct relatively powerful wind power plants at the sites of the most favorable wind conditions with small outlays for the power transmissionlines. The wind power plant electricity can be used to electrify the production processes in agriculture, while the surplus can be supplied to the energy system. The inclusion of the wind power plants in the energy system makes it possible to improve the total generation of energy or reduce the consumption of fuel. With the efficient arrangement of the wind power plants, one can also reduce the energy losses during its transfer. Calculations indicated that in the coastal zones of the Estonian SSR, one can obtain specific power of 420-480 kW/km/sup 2/. For comparison it is indicated that the Estonian SSR in the agricultural regions now uses 8-12 kW/km/sup 2/. The wind-energy potential of the coastal ...
Abstract The aim of this project was to develop an OPC server to communicate over an RS232 serial line. This communication media is commonly used with commercial instruments. The development was made for a High Voltage power supply in the context of the Alice [1] experiment. In addition, the structured modular concept will allow changing the transmission media or power supply type with little effort. The high voltage power supply should be accessible remotely through a network. OPC[2] is an acronym for OLE[3] for Process Control. OPC is based on the DCOM [3] communication protocol, which allows communication with any computer running a Windows based OS. This standard is widely used in industry to access device data through Windows applications. The concept is based on the client-server architecture. The hardware and the software architecture are described. Subsequently details of the implemented programs are given with emphasis on the ...
Nova Corporation and its related businesses are involved in natural gas production, gas pipelines, consulting services, and upgrading of natural gas into chemicals and plastics. Nova owns Alberta Gas Transmission Division, the primary gas transportation system in Alberta, with 11,400 miles of pipeline and total deliveries in 1992 of 3.4 trillion ft"3. Nova also owns 50% of Foothills Pipe Lines Ltd., one of Canada's largest carriers of exported gas, and 50% of TQM Pipeline Partnership, which transports natural gas in Quebec. Nova conducts its chemicals business through Novacor Chemicals Ltd., which has plants in Alberta, Ontario, Quebec, and the USA. Novacor's major petrochemicals are methanol, ethylene, propylene, and styrene and its major plastics are polystyrene, polypropylene, and polyethylene. Nova's gas-producing branch Novalta Resources produced 26 billion ft"3 of natural gas in 1992 and has proven reserves of 334 billion ft"3. Nova's net ...
A multivariate adaptive power system stabilizer is proposed. The advantages of using coordinated governor and excitation control are discussed, and the problems associated with constant parameter power system stabilizers (CPSS) are highlighted. The proposed multi-input multi-output (MIMO) power system stabilizer can coordinate the governor and excitation control and can overcome the problems associated with CPSS in power system stabilization. Selective multivariable state modelling, identification and control methods are investigated and the MIMO least squares technique with variable forgetting factor is used for system identification, guaranteeing good parameter tracking after a disturbance. Two multivariable self-tuning algorithms are investigated, the generalized minimum variance control and pole-shifting control algorithms. The multivariable self-searching pole-shifting algorithm is developed. Models of a single machine connected to an infinite bus through a double circuit ...
Phenomena associated with induced currents and voltages on high voltage transmissionlines were discussed. Basic principles were reviewed. Action taken by Hydro-Quebec to assess the importance of associated problems on its grid was described. Hydro-Quebec`s findings and recommendations were compared with those of the International Standard, IEC 1129. It was concluded that for most cases, induced currents and voltages were higher than those listed under Class A recommendations of IEC 1129 as rated switching capabilities for ground switches assigned to this duty. For worst case scenarios, it was also found that, values of induced currents and voltages were lower than those of Class B recommendations. Hydro-Quebec and GEC Alsthom T and D collaborated to design and type test a full range of low cost and efficient ground interrupter switches tailored to Hydro-Quebec`s needs. A list of general application criteria of ground interrupter switches that ...
Al{sub x}Ga{sub 1{minus}x}P layers (0 {le} x {le} 0.7), with thicknesses of {ge}1 {micro}m were grown on Si (100) wafers by metal-organic molecular beam epitaxy (MOMBE) at 450 C. Transmission electron micrographs of the single crystal films revealed that the microstructure contains stacking faults and microtwins especially near the interface as well as both threading and misfit dislocations. Hardness and elastic modulus were measured using a Nanotest 500 indenter, which can probe the film properties without influence from the substrate. The hardness H varies linearly according to (11.8 {minus} 2.3x) GPa. The absence of alloy hardening is due to the fact that there is no difference in atomic size of Al and Ga. The indentation modulus E/(1{minus}v{sup 2}) decreases monotonically from 136 GPa for GaP to 129 GPa for Al{sub 0.7}Ga{sub 0.3}P and bows only slightly (about 2%) below the straight line of linear interpolation.
Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmissionline magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and measurements are explained.
The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including Fresnel lens and phase ...
With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the result of the model calculation, anomaly detection may be found ...
Fault current limiters (FCLs) are devices for to suppress current in electric power system. The FCL is extensively expected to suppress fault current, particularly required for trunk power systems heavily connected high-voltage transmissionlines, such as 500 kV class power system. For this reason, FCLs based on various principles of operation have been developed. Most of the FCLs under development which employ superconductors are based on the quenching phenomenon peculiar to the superconducting state, that is, making use of a rapid transition to normal conducting state, an electrical resistance appears, and this resistance is used to suppress fault currents. However, this elevation of resistance, although increasing the fault current suppression effect, also tend to raise the overvoltage occurring FCL, the ascertainment of the overvoltage is important as regards the protection of the FCL as well as other power system devices. Hence the ...
The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional power plants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal power plants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO_2 in the atmosphere is voiced. For nuclear power plants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is characterized as is thermal pollution of water flows and the environmental impact of cooling towers. Other factors are also mentioned, such as the ...
In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated TransmissionLine (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have extended the work on this ...
This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmissionlines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields ...
Whether exposure to electromagnetic fields (EMFs) cause cancer has been vigorously debated for many years and has been the most vexing issue with which ICNIRP has had to deal during its short existence. There have been three parts of the electromagnetic spectrum that the issue of cancer has raised: static (0 Hz) magnetic fields, extremely low frequency (ELF) fields (defined as > 0-300 Hz, but concerns have been raised almost exclusively at the power frequencies of 50/60 Hz), and radiofrequency (RF) fields (300 Hz -300 GHz). By far the major problems have arisen during the construction of new high voltage transmissionlines and mobile telephone systems. Actions by protest groups concerned with possible health effects, especially with cancer in children, has now reached such a scale that it is costing electrical utilities and communications companies billions of dollars annually world-wide. With such high stakes, ICNIRP has had to be extremely ...
The French nuclear power program was pushed through in order to reduce the country's dependence on imported fossil sources of energy. Nuclear power and hydro power have achieved a level of self-sufficiency in the energy sector of more than 50%. It should be emphasized that the French nuclear power program was largely self-financed. Electricite de France (EdF) considers itself well prepared for the European market, provided the creation of the single market implies that electricity rates are taken as a yardstick of competitiveness. Negotiations about a European directive on deregulating the electricity market were for the government to hold. EdF pleaded in favor of preserving for each country a certain leeway for shaping its own policy. The road to deregulation was to be opened, but the specific situation of each country was to be taken electricity to be passed through imposes narrow constraints upon an expansion of exchanges of electricity, and public acceptance is not very likely to ...
It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as power plants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this system to the thermal power plant location program and to the construction of underground transmission ...
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmissionlines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. ...
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmissionlines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. Alternatively, a low ...
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load voltage ranged from one to two megavolts. The experiments demonstrated efficient power flow through a long, ...
Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmissionlines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their location regular maintenance coatings are ...
Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.
Many epidemiological studies have investigated residential exposure to extremely-low-frequency magnetic field (ELF-MF) for children, but exposure at schools where children may stay up to 8 h every weekday was rarely considered. Between March and June 2004, we carried out a field study in Taipei City and County of northern Taiwan to explore ELF-MF exposure pattern among children at schools with high voltage transmissionlines (HVTL) running through the campuses. One hundred and one children attending 14 schools with nearby HVTL (exposed group) and 123 children of 18 schools at least 100 m away from HVTL (unexposed group) were monitored for 24-hour personal ELF-MF exposure. Selected classrooms and playgrounds within the buffer regions (i.e., within 30 m of HVTL) and those away from the buffer regions were also assessed, using spot measurements, to determine the extent to which HVTL may contribute to the environmental exposure on campuses. Results ...
This paper proposes a novel and efficient algorithm to obtain optimal generation dispatch reflecting the operator's intention in power system rescheduling. In optimal system operation, various objectives, such as economy, quality and transmission security, need to be achieved simultaneously. However, these objectives are often contradictory and in a trade-off relationship with respect to each other thus making it difficult to handle this class of problem by conventional approaches. In the proposed algorithm, optimal generation dispatch is formulated as a multi-objective optimization problem. A fuzzy coordination technique based on fuzzy set theory is used to obtain an optimal solution. Evaluation indices composed of fuel cost, transmissionline overload and AFC regulation capacity margin are measured by the membership functions, and multi-objective optimization is solved by maximizing the composite performance ...
Vacuum glazing consists of an evacuated space between two sheets of glass. Vacuum glazing has a large effect on energy savings in houses and buildings. Vacuum glazing can achieve higher insulating performance than conventional insulated glazing. Nippon Sheet Glass has successfully developed conventional vacuum glazing. In this study we investigated an advanced form of vacuum glazing. Its thermal insulation ability is equivalent to 100 mm thick glass wool thermal insulation. This vacuum glazing contained a SnO_2:F low emissivity surface. The influence of the residual gas in a vacuum space on heat flow is important to performance. For long-term thermal stability, it is very important to maintain vacuum stability. To understand this better, we studied the behavior of outgassing from the inside glass surfaces exposed to an ...
Background Since 2007, sex has been the major mode of HIV transmission in China, accounting for 75% of new infections in 2009. Reducing sexual transmission is a major challenge for China...Full Text Available
The relationship between malaria transmission intensity and clinical disease is important for predicting the outcome of control measures that reduce transmission. Comparisons of hospital data...Full Text Available
BackgroundMother-to-Child Transmission (MTCT) of HIV remains the main mode of acquisition of HIV in children. Transmission of HIV may occur during pregnancy, delivery or breastfeeding....Full Text Available
A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.
The Minami-Iwaki trunk line now under construction by Tokyo Electric Power Company is an UHV transmissionline which covers 130km from the central region of the Abukuma highlands, Fukushima Prefecture, through the northern ridge of the Kanto Plain to Imaichi City, Tochigi Prefecture and has 235 steel towers. About 30% of the ground along the above route is mainly layers of sand and gravel. Accordingly it has become urgent to design rationally the pile foundations in the sand and gravel layers. Hence the company has studied an estimation method of the ultimate bearing power of cast-in-place piles penetrating the sand and gravel layers and the displacement of pile heads. In this report, the result of the above study is described. The company has so far used the equations in accordance to the Meyerhof equations for the estimations of the ultimate bearing power and this time, this equations have been examined for its ...
This work is a theoretical investigation on the physical properties of semiconductor-based two-dimensional photonic crystals, in particular for what concerns systems embedded in planar dielectric waveguides (GaAs/AlGaAs, GaInAsP/InP heterostructures, and self-standing membranes) or based on macro-porous silicon. The photonic-band structure of photonic crystals and photonic-crystal slabs is numerically computed and the associated light-line problem is discussed, which points to the issue of intrinsic out-of-lane diffraction losses for the photonic bands lying above the light line. The photonic states are then classified by the group theory formalism: each mode is related to an irreducible representation of the corresponding small point group. The optical properties are investigated by means of the scattering matrix method, which numerically implements a variable-angle-reflectance experiment; comparison with experiments is also provided. The ...
This dissertation deals with the control of active power flow, or load flow in electric power systems. During the last few years, interest in the possibilities to control the active power flows in transmission systems has increased significantly. There is a number of reasons for this, coming both from the application side - that is, from power system operations - and from the technological side. where advances in power electronics and related technologies have made new system components available. Load flow control is by nature a multi-input multi-output problem, since any change of load flow in one line will be complemented by changes in other lines. Strong cross-coupling between controllable components is to be expected, and the possibility of adverse interactions between these components cannot be rejected straightaway. Interactions with dynamic phenomena in the power system are also a source of concern. Three ...
In cold countries, the design of transmissionlines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud icing, glaze caused by freezing rain, wet ...
This paper presents a real-time wavelet-Fuzzy combined approach for digital relaying. The algorithm for fault classification employs wavelet multi resolution analysis (MRA) to overcome the difficulties associated with conventional voltage and current based measurements due to effect of factors such as fault inception angle, fault impedance and fault distance. The proposed algorithm for fault location, different from conventional algorithms that are based on deterministic computations on a well-defined model to be protected, employs wavelet transform together with fuzzy logic. The wavelet transform captures the dynamic characteristics of the non-stationary transient fault signals using wavelet MRA coefficients. The fuzzy logic is employed to incorporate expert evaluation through fuzzy inference system (FIS) so as to extract important features from wavelet MRA coefficients for obtaining coherent conclusions regarding fault location. Computer simulations using MATLAB have been conducted ...
We find that tachyonic orbifold examples of AdS/CFT have corresponding instabilities at small radius, and can decay to more generic gauge theories. We do this by computing a destabilizing Coleman-Weinberg effective potential for twisted operators of the corresponding quiver gauge theories, generalizing calculations of Tseytlin and Zarembo, and interpreting them in terms of the large-N behavior of twisted-sector modes. The dynamically generated potential involves double-trace operators, which affect large-N correlators involving twisted fields but not those involving only untwisted fields, in line with large-N inheritance arguments. We point out a simple reason that no such small radius instability exists in gauge theories arising from freely acting orbifolds, which are tachyon free at large radius. When an instability is present, twisted gauge theory operators with the quantum numbers of the large-radius tachyons aquire vacuum expectation ...
GaAs-based dc high voltage photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. This paper describes techniques to maintain good vacuum while delivering beam, and techniques that minimize the ill effects of ion bombardment, the dominant mechanism that reduces photocathode yield of a GaAs-based dc high voltage photogun. Experimental results presented here demonstrate enhanced lifetime at high beam currents by: (a) operating with the drive laser beam positioned away from the electrostatic center of the photocathode, (b) limiting the photocathode active area to eliminate photoemission from regions of the photocathode that do not support efficient beam delivery, (c) using a large drive laser beam to distribute ion damage over a larger area, and (d) by applying a ...
The rate coefficient for the title reaction has been determined using mixtures of nitric acid (HNO{sub 3}), carbon monoxide (CO), and argon in incident shock wave experiments. Upon shock heating, the nitric acid rapidly decomposes into OH and NO{sub 2}. The OH subsequently reacts predominantly via the title reaction. Quantitative OH time histories were obtained by continuous-wave (cw) narrow-linewidth UV laser absorption of the R{sub 1}(5) line of the A{sup 2}{Sigma}{sup +} {l_arrow} X{sup 2}{Pi}{sub i} (0,0) transition at 32,606.56 cm{sup {minus}1} (vacuum). In some experiments, helium was added to the reactant mixture to examine CO vibrational excitation effects on the rate coefficient determination. It was found that the rate of excited CO (v = 1) with OH is less than the rate of ground-state CO (v = 0) with OH, which is in agreement with previous state-dependent work. The experiments were conducted over the temperature range 1,090--2,370 K ...
Transtelephonic electrocardiographic transmission (TET) is the most widespread form of telecardiology since it enables clinicians to assess patients at a distance. The purpose of this study was to assess...Full Text Available
Glycine is a major inhibitory neurotransmitter in the spinal cord and brainstem. Recently, in vivo analysis of glycinergic synaptic transmission has been pursued in zebrafish using...Full Text Available
Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, and the spatial relationship between primary ...
A solid electrolyte cell comprises an alkali metal anode, e.g. lithium, a halogen-containing organic polymer cathode and a solid elecrolyte between the anode and the cathode. The cathode comprises iodine-containing vacuum-cyclised polyacrylonitrile, and the solid electrolyte is preferably lithium iodide and halogen-free vacuum-cyclised polyacrylonitrile. This patent also discloses the use of isotactic polyacrylonitrile, a method of making a cathode comprising iodine-containing vacuum-cyclised polyacrylonitrile, and novel methods of making the solid elecrolyte cells described.
The Dental Investigation Service, USAFSAM, Brooks AFB, has outlined the need for a vacuum unit to be used in the Air Force dental clinics. The unit must be capable of effectively picking up mercury and at the same time not redistribute mercury vapors throughout the dental clinic during normal operations or mercury-spill situations. The Dental Investigation Service selected the MRS-3, Minuteman Mercury Recovery System, product of American Cleaning Equipment Corporation as the mercury vacuum to be used for T E. The USAF OEHL/ECH was requested by the Dental Investigation Service to perform the T E on the MRS-3 for possible health hazards due to exposures of mercury vapors.
Purification parameters of the vacuum distillation process for AM50A and AZ31B magnesium alloy were studied. The vacuum distillation tests were kept at 580 C to 620 C up to 10 h under a vacuum pressure of about 1 Pa. The purification ratio for AM50A magnesium alloy increases with increasing the purification time. The chemical compositions of materials deposited purifying at 580 C for AM50A magnesium alloy almost satisfy the values for pure magnesium specified by JIS standard specification. The chemical compositions of deposited materials at 600 C for AZ31B magnesium alloy satisfy the values specified by the standard specification except for Zn. (orig.)
We investigate the solar neutrino problem in the scenario of three generation neutrino oscillation hypothesis, taking into account other phenomenological constraints to the neutrino mixing and mass parameters.
Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...
A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.
This paper presents the results of the degree of irreversible changes of dielectric properties of vacuum circuit breakers with CuCr and CuBi contacts before and after short-circuit breaking operations. Tests of dielectric properties were performed on four different types of switching vacuum chamber with RMF electrodes in the form of a spiral disk with slots. The paper describes the configuration of measuring system for determining the dielectric properties of circuit breakers with DC, AC and pulse voltage. It also describes the measuring procedure. The results were analyzed and the experimentally obtained random variable breakdown voltage is found to belong to Weibull distribution in all cases. Based on these results it was found that for the vacuum circuit breakers with CuCr contacts and ...
A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.
The authors solve the instability of perturbative vacuum of Gross-Neveu model. They use a variational method. The analysis is nonperturbative as it uses only equal time commmutator/anticommutator algebra.
We have established a cartilaginous fish cell line [Squalus acanthias embryo cell line (SAE)], a mesenchymal stem cell line derived from the embryo of an elasmobranch, the spiny dogfish...Full Text Available
Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc ...
> Develoopments which have imporved fuel core quality and reduced production costs are described. These developments in the melting and casting of uranium ingots arei modification of the crucible and knockout-slide assembly, substitution of uncoated crucibles for coated crucibles, and substitution of a one-piece gun barrel mold for a vertically split mold. (N.W.R.)
The Technical Safety Requirements (TSRs) for the Cold Vacuum Drying Facility define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation. Controls required for public safety, significant defense-in-depth, significant worker safety, and for maintaining radiological and toxicological consequences below risk evaluation guidelines are included.
A technique has been developed for joining a large calcium fluoride crystal to a stainless-steel flange by means of a silver transition ring. The process involves both vacuum brazing using a copper-silver alloy and air brazing using silver chloride. This paper describes the procedure used in fabricating a high-vacuum leak-tight calcium fluoride window assembly.
An algebraic formulation of the electromagnetic field in which various quantization procedures can be described was chosen to discuss perturbation calculations. It is shown that the Feynman rules and the second order calculation of the self-energy of the electron can be developed on the basis of the Fermi method of quantization. The algebraic approach clarifies the problems in defining the vacuum and other states which are associated with calculations in terms of field algebra operators. It is demonstrated that the vacuum state defined on the field algebra by Schwinger leads to incorrect results in the self-energy calculation.
Throughout the last decades, plasma technology has been established in a series of surface treatment applications, e.g. for semiconductor processing or optical coatings. The majority of plasma assisted technologies is based on low pressure processes. In recent years, however, non-thermal atmospheric pressure discharges have attracted considerable interest because of their simplified technical devices for industrial applications as compared to low pressure processes which require vacuum equipment. Hence, batch processing can be avoided, thus facilitating the implementation of plasma process steps into production lines. Investment costs are cut down significantly. The use of atmospheric pressure plasmas for technical applications dates back to the ozone production with dielectric barrier discharges (DBD) by Siemens in 1857. Lately, the application of atmospheric pressure plasmas for surface treatment has been reported, e.g. for the treatment of ...
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm ...
We analyze the stability of the structure equations of the vacuum in the brane world models, by using both the linear (Lyapunov) stability analysis, and the Jacobi stability analysis, the Kosambi-Cartan-Chern theory. In the brane world models the four-dimensional effective Einstein equations acquire extra terms, called dark radiation and dark pressure, respectively, which arise from the embedding of the three-brane in the bulk. Generally, the spherically symmetric vacuum solutions of the brane gravitational field equations have properties quite distinct as compared to the standard black hole solutions of general relativity. We close the structure equations by assuming a simple linear equation of state for the dark pressure. In this case the vacuum is Jacobi stable only for a small range of values of the proportionality constant relating the dark pressure and the dark radiation. The unstable trajectories on the brane behave ...
The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between ...
Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum slanting ...
Abstract In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-critical health information and nodes of non-critical health information. The CR-MAC protocol prioritizes the critical packets access to the transmission medium by transmitting them with higher power while transmitting lower priority packets using lower transmission power. At the receiver, a higher priority packet experiences collision only when there are more than one critical packet transmission at the same transmission slot while non critical packets experience collision when there are more than one transmission at the same transmi...
Temperature and concentration profiles of CO in a laminar, axisymmetric, premixed methane-air Bunsen flame are measured using line-of-sight diode laser absorption spectroscopy and computer tomographic (CT) reconstruction. Absorption spectra for P(20) (v=2<-1) and P(27) (v=1<-0) vibrotational transitions of CO were measured at 21 evenly spaced positions over a 1.33 cm span for a 1.3 cm radius flame. CT reconstruction algorithm was based on Fourier convolution. The tomographically reconstructed normalized transmission profiles derived from absorption spectra, in conjunction with a quantum mechanical model for vibrotational behavior of CO, yielded both temperature and concentration profiles. The Bunsen flame had 3 distinct zones: an inner rich-premixed flame zone, an outer non-premixed flame zone and an unburnt core region. The reconstructed temperature profile showed that the core region temperature was close to ambient and rapidly ...
A common practice of electric utilities experiencing transmission and distribution (T and D) system overloads is to expand the substation, add lines, or upgrade equipment, all of which are capital intensive options. In 1988, it was hypothesized that strategically sited photovoltaics (PV) could benefit parts of T and D systems near or at overloaded conditions. An evaluation methodology was developed and applied to a test case (Kerman Substation near Fresno, California). Analytical results suggested that the value of PV to the T and D system could substantially exceed its energy and generation capacity value. The importance of this finding indicated the need for empirical validation. This led to the construction of a 0.5 MW PV demonstration plant by Pacific Gas and Electric Company (PG and E) at Kerman, California as part of the PVUSA (PV for Utility Scale Applications) project. PVUSA is a national public-private partnership that is assessing and ...
A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement system has been newly developed, and successfully applied to actual preparatory ...
Zinc oxide (ZnO) and alumina (Al2O3) particles are synthesized by the combustion of their volatilized acetylacetonate precursors in a premixed air-methane flame reactor. The particles are characterized by XRD, transmission electron microscopy, scanning mobility particle sizing and by measurement of the BET specific surface area. Pure (?-)alumina particles appear as dendritic aggregates with average mobile diameter 43-93 nm consisting of partly sintered, crystalline primary particles with diameter 7.1-8.8 nm and specific surface area 184-229 m2/g. Pure zinc oxide yields compact, crystalline particles with diameter 25-40 nm and specific surface area 27-43 m2/g. The crystallite size for both oxides, estimated from the XRD line broadening, is comparable to or slightly smaller than the primary particle diameter. The specific surface area increases and the primary particle size decreases with a decreasing flame temperature and a decreasing precursor ...
In this work, {beta}-SnS{sub 2} thin films have been prepared on glass substrates by the spray pyrolysis technique using an alcohol solution which contains tin chloride (SnCl{sub 4}) and thiourea (SC(NH{sub 2}){sub 2}) as precursors. The structural study shows that {beta}-SnS{sub 2} thin film prepared using optimal experimental conditions: substrate temperature T{sub s} = 280 deg. C and the concentration ratio of sulfur and tin elements in the spray solution x = [S]/[Sn] = 2.5, crystallizes in the hexagonal phase with a strong (0 0 1) X-ray diffraction line. In the same way, microprobe analyses (EPMA) as well as X-ray photoelectron spectroscopy (XPS) show the presence of undiserable phase of SnO{sub 2}. From the transmission and reflectance spectra, the band gap energy is 2.65 eV. On the other hand, the photothermal properties of such films have been studied, the thermal conductivity was K{sub c} = 0.85 W m{sup -1} K{sup -1} and the thermal ...
In this work, ?-SnS2 thin films have been prepared on glass substrates by the spray pyrolysis technique using an alcohol solution which contains tin chloride (SnCl4) and thiourea (SC(NH2)2) as precursors. The structural study shows that ?-SnS2 thin film prepared using optimal experimental conditions: substrate temperature Ts = 280 deg. C and the concentration ratio of sulfur and tin elements in the spray solution x = [S]/[Sn] = 2.5, crystallizes in the hexagonal phase with a strong (0 0 1) X-ray diffraction line. In the same way, microprobe analyses (EPMA) as well as X-ray photoelectron spectroscopy (XPS) show the presence of undiserable phase of SnO2. From the transmission and reflectance spectra, the band gap energy is 2.65 eV. On the other hand, the photothermal properties of such films have been studied, the thermal conductivity was Kc = 0.85 W m-1 K-1 and the thermal diffusivity was Dc = 14.5 x 10-6 m2 s-1. The analysis of ?-SnS2 thin ...
Dams and reservoirs are among one of the most sensitive of all development Project, in terms of pervasiveness of their influence in altering the environmental conditions and resources. In the present study, major dams and reservoir projects are reviewed, from the environmental point of view. Dams and Reservoir projects bring about major changes in the immediate environment, thus affecting public health, settlements, farmlands, roads and historical sites. Impacts on human population and wildlife may be profound. Tropical diseases, involving fresh-water hosts or vectors in their transmission, are often common around new reservoirs. Large lakes create limnological changes, excessive evaporation, seepage, disturbance in water-table and increased tendencies of landslides and earthquakes. Micro climatic changes are possible, such as fog formation, increased cloudiness and modified rainfall-patterns. Retention of sediment results in silting up of reservoirs. Water ...
The effect of thermal pretreatment in N[sub 2] up to 723 K and the activation treatments in H[sub 2] and an inert atmosphere on the properties of Ni and Co activated-charcoal-supported catalysts were studied. Catalysts were characterized by means of N[sub 2] adsorption at 77 K, H[sub 2] chemisorption at room temperature, thermogravimetric analysis (TGA), X-ray diffraction (XRD), and transmission electron microscopy (TEM). The catalysts' activity and selectivity for acetone hydrogenation to 2-propanol under unusual and severe conditions (473 K and high overall acetone conversion) were also measured. TGA and XRD evidence was found for the charcoal-support-promoted NiO and CoO reduction to the metallic states when the catalysts were subjected to an inert atmosphere above 723 K caused a loss of acetone hydrogenation activity (calculated on a metal load basis) for both the Ni and Co activated-charcoal-supported catalysts, with respect to that of the ...
In 1978, China's coal mining industry achieved an output of 618,000,000 metric tons of raw hard coal, an increase of 128,000,000 tons compared with 1977. This has been achieved primarily by increased new mine development and the modernizaion and expansion of existing mines. While 96% of China's coal is currently produced from underground mines, only 33% of this output is from full mechanized operations, i.e., mechanized longwall retreat faces. Over 1% is produced by hydraulic mining. The current Ten-Year Plan (1975-1985) established that the major thrust of new development and activity should be made particularly in the Shandong, Anhui, Henan, Guizhou, and Yunnan provinces. China is presently concentrating on the construction/enlargement of eight major coal mining centers, mainly in the north and northeast of the country, each with a designed capacity in excess of 10,000,000 tons a year. China has elected to import large quantities of mining machinery and equipment, ...
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own plane. At various ...
There is an increasing interest in using novel methods to generate electrical energy using wind and solar energy sources. Unfortunately, such energy sources are intermittent, and, therefore, conventional sources must still be available to meet demand during critical periods. In addition, renewable energy technologies are still expensive in general, although extensive research programs are being conducted to overcome this disadvantage. Hence, reliability, economic assessment and environmental impacts are three objectives to be satisfied simultaneously when designing either an autonomous or a grid-connected hybrid power generation system. The installation of any of these two systems should, undoubtedly, be preceded by an assessment of the available resources at the candidate site. In addition, many other factors are to be studied, including economics of transmissionlines, site constraints, distances etc. In this thesis, the subjective judgments ...
We have conducted a systematic investigation of the origin and underlying physics of the line--line and line--continuum correlations of AGNs, particularly the Baldwin effect. Based on the homogeneous sample of Seyfert 1s and QSOs in the SDSS DR4, we find the origin of all the emission-line regularities is Eddington ratio (L/Ledd). The essential physics is that L/Ledd regulates the distributions of the properties (particularly column density) of the clouds bound in the line-emitting region.
BackgroundPlasmodium falciparum morbid and fatal risks are considerably higher in areas supporting parasite prevalence ≥25%, when compared with low transmission...Full Text Available
A mollusciciding campaign was begun in Cul-de-Sac Valley, St Lucia, at the end of 1970, following several years of epidemiological studies in which transmission of Schistosoma mansoni...Full Text Available
To gain insight into the process of mitochondrial transmission in yeast, we directly labeled mitochondrial proteins and mitochondrial DNA (mtDNA) and observed their fate after the fusion of two cells....Full Text Available
This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.
The transmissible gastroenteritis coronavirus (TGEV) infects the epithelial cells of the intestinal tract of pigs, resulting in a high mortality rate in piglets. This study shows the interaction of...Full Text Available
AIM: To examine the determinants of maternal-neonatal transmission of hepatitis B virus (HBV).METHODS: A nested case-control study was conducted in Changsha, Hunan, People’s Republic...Full Text Available
As a part of the WE-NET project, the tanker for liquid hydrogen transport was studied. In fiscal 1996, some experiments and numerical analyses were proposed which are necessary to solve technological issues extracted in fiscal 1995 for heat insulation structure. The issue was roughly classified into vacuum and non-vacuum insulation, and their basic functions and required performance were arranged. Boil-off rate of 0.2-0.4%/d was targeted. The insulation system which applies polyurethane form (PUF) to tank surfaces and injects atmospheric N2 gas into the surrounding hold space, could achieve the targeted insulation performance by PUF of 1m in thickness. The system of vacuum panel insulation and atmospheric N2 gas injection into a hold space required the panel of 500mm in thickness because of the large effect of metallic outer panel material. The system of vacuum hold and PUF panels was faced with the ...
Transmissions of sperm by unirradiated and irradiated cotton bollworm, Helicoverpa armigera, were studied by live dissection of females immediately after the initiation of mating. In cotton bollworm the sperm transfer was rather a complex process. In fact unirradiated males failed to transfer sperm in about 19% of their matings. When irradiated with 250 Gy and 400 Gy, aberrations of sperm transmission were about 21% and 50% respectively. The failure of spermatophore 'cap' location was an important reason of sperm transmission aberrations. When females mated to high-dose-irradiated males, their oviposition response appeared abnormal
A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)
On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small coverage {delta}{theta} from the coverage of a pumping point ...
One hope to solve the cosmological constant problem is to identify a symmetry principle, based on which the cosmological constant can be reduced either to zero, or to a tiny value. Here, we note that requiring that the vacuum state is Lorentz invariant significantly reduces the theoretical value of the vacuum energy density. Hence, this also reduces the discrepancy between the observed value of the cosmological constant and its theoretical expectation, down from 123 orders of magnitude to 56 orders of magnitude. We find that, at one loop level, massless particles do not yield any contribution to the cosmological constant. Another important consequence of Lorentz symmetry is stabilization of the gravitational hierarchy: the cosmological constant (divided by Newton's constant) does not run as the quartic power of the renormalization group scale, but instead only logarithmically.
Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.
We have measured time-resolved laser-induced incandescence of flame-generated soot under high-vacuum conditions (4.1?10?6 mbar) at an excitation wavelength of 532 nm with laser fluences spanning 0.06?0.5 J/cm2. We generated soot in an ethylene/air diffusion flame, introduced it into the vacuum system with an aerodynamic lens, heated it using a pulsed laser with a spatially homogeneous and temporally smooth laser profile, and recorded LII temporal profiles at 685 nm. At low laser fluences LII signal decay rates are slow, and LII signals persist beyond the residence time of the soot particles in the detection region. At these fluences, the temporal maximum of the LII signal increases nearly linearly with increasing laser fluence until reaching a plateau at ?0.18?J/cm2. At higher fluences, th...
In order to understand the parameters of the standard model of electroweak and strong interactions (coupling constants, masses, mixing angles) one needs to embed the standard model into some larger theory that accounts for the observed values. This means some additional sector is needed that fixes and stabilizes the values of the fundamental constants of nature. In these lecture notes we describe in nontechnical terms how such a sector can be constructed. Our additional sector is based on rapidly fluctuating scalar fields that, although completely deterministic, evolve in the strongest possible chaotic way and exhibit complex behaviour. These chaotic fields generate potentials for moduli fields, which ultimately fix the fundamental parameters. The chaotic dynamics can be physically interpreted in terms of vacuum fluctuations. These vacuum fluctuations are different from those of QED or QCD but coupled with the same moduli fields as QED and QCD ...
Various initiatives have been undertaken by the Federal Energy Regulatory Commission (FERC) to deregulate wholesale electric energy markets. These initiatives have focused on restructuring the transmission systems in the US and recently have culminated in a proposal requiring formation of and participation in regional transmission organizations. The overall form of regulation selected to determine rates for transmission entities as well as underlying regulatory decisions reached on key issues will have profound implications for transmission entities. For example, traditional cost-based regulation would require one set of accounting and reporting rules, while incentive-based regulation may not be subject to those same rules. An overview of some of the major accounting and financial reporting issues that will need to be considered is presented.
We study from a critical perspective several quantum-electrodynamic phenomena commonly related to vacuum electromagnetic (EM) fluctuations in complex media. We compute the resonance-shift, the spontaneous emission rate, the local density of states and the van-der-Waals-Casimir pressure in a dielectric medium using a microscopic diagrammatic approach. We find, in agreement with some recent works, that these effects cannot be attributed to variations on the energy of the EM vacuum but to variations of the dielectric self-energy. This energy is the result of the interaction of the bare polarizability of the dielectric constituents with the EM fluctuations of an actually polarized vacuum. We have found an exact expression for the spectrum of these fluctuations in a statistically homogeneous dielectric. Those fluctuations turn out to be different to the ones of normal radiative modes. It is the latter that carry the ...
Total thyroidectomy involving the adjacent structures of the trachea can cause tracheal damage such as early tracheal necrosis. The authors describe the first case of anterior tracheal necrosis following...Full Text Available
A scheme is presented for the generation of entangled states for two cavity mirrors. In the scheme each mirror initially in a vacuum state interacts with a weak coherent field, resulting in a photon-number dependent kick. The detection of a photon leaking from the cavities collapses the two mirrors to an entangled state.
Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was ...
A Monte Carlo simulation of the vacuum Bianchi type-IX (mixmaster) cosmology yields a significant correlation between large universe volume and high anisotropy. An analog of the model's chaotic classical behavior is seen in the break up of the universe wave function at large volume into fingers in the corners of the minisuperspace anisotropy potential.
Progress is reported in fabrication and coating activities being conducted for the weapons program, nuclear test program, nuclear design program, magnetic fusion program, and miscellaneous applications. (DLC)
Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.
Bulk monomer MMA was impregnated into simul, a fuel wood of Bangladesh, under vacuum and under normal temperature and pressure conditions in order to compare the mode of impregnation and its effect on various characteristic parameters of wood plastic composites. Methanol (MeOH) was used as the swelling solvent with methylmethacrylate (MMA) at MMA: MeOH = 70:30, v/v. Impregnation of the bulk monomer was very high under vacuum compared to that at normal condition; but the difference of grafting of MMA to the wood cellulose under these two impregnating conditions was much lower as compared to that of the uptakes of impregnating solution MMA + MeOH under these two modes of impregnation. Incorporation of additives to MMA + MeOH has substantially enhanced grafting, tensile strength, bending strength and compression strength of the composite to such an extent that there is virtually very little difference between vacuum ...
This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)
Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined ...
Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined ...
The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.
The recovery of schistosome cercariae from natural waters has been limited by variations in turbidity and in the accuracy of recovery with different techniques. A modification of the Rowan vacuum paper...Full Text Available
We provide an example in which the Heisenberg and the Schroedinger pictures of quantum mechanics give different results, thus confirming the statement of P.A.M. Dirac that the two pictures may lead to inequivalent results. We consider a one-dimensional nonrelativistic charged harmonic oscillator (frequency {omega}{sub 0} and mass m), and take into account the action of the radiation reaction and the vacuum electromagnetic forces on the charged oscillator. We show that the Heisenberg picture gives the correct value, {Dirac_h}{omega}{sub 0}/2, for the ground state energy of the harmonic oscillator in both cases of classical and quantized vacuum fields. In the case of the Schroedinger picture, considering classical vacuum fields, and using a simple calculation for the classical radiation reaction force that is valid in the limit of large mass (mc{sup 2} >> {Dirac_h}{omega}{sub 0}), we obtain the value ...
Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements done with an atmosphere ...
A four-block collimator installed on a control table for positioning the alignment reference marks. Designed for use with SPS secondary beams, the collimator operates under vacuum conditions. See Annual Report 1976 p. 121 and photo 7701014.
The choice of vacuum state for a quantum scalar field propagating in a de Sitter spacetime (massive and arbitrarily coupled to the gravitational field) is discussed. The problem of finite-time initial conditions for the mode functions is analyzed, as well as how these determine the vacuum state of the quantum system. The principle guiding the choice of vacuum state is the following: one wants the vacuum contribution to the energy-momentum tensor to contain all the ultraviolet divergent terms, so that the particle creation terms are finite, and covariantly conserved. There is a suitable set of modes (instantaneous adiabatic basis) in which this splitting of the expectation value of the energy-momentum tensor can be carried out. Numerical results are presented for different finite-time initial conditions (m = 0.6, {zeta} = 1/6). The nature of the particle creation effect is described and its relationship ...
We simplify and generalize an argument due to Bowcock and Watts showing that one can associate a finite Lie algebra (the 'classical vacuum preserving algebra') containing the Moebius sl(2) subalgebra to any classical W-algebra. Our construction is based on a kinematical analysis of the Poisson brackets of quasi-fields. In the case of the W_S"G-subalgebra S of a simple Lie algebra G, we exhibit a natural isomorphism between this finite Lie algebra and G whereby the Moebius sl(2) is identified with S. (orig.).
The vacuum polarization splitting of the M-shell states in muonic hydrogen can have a profound influence on the muonit de-excitation cascade in deuterium and tritium targets. The cascade also shows sensitive dependence on the precise rate of transfer processes between certain excited muonic deuterium and tritium atoms. Recent experimental data, where a much greater population of the (d..mu..) qs state (1/sub 1//sub //sub s/) was found than previously predicted, can be explained if the transfer rates from the (d..mu..) M-shell are assumed to be strongly suppressed.
Thermal desorption spectroscopy (TDS) was used to study outgassing from polycrystalline SiGe (poly-SiGe), SiC and SiO"2 films used for poly-SiGe-based MEMS thin film vacuum package technology. Primary desorption products were found to be H"2, H"2O and CO"2. The CO"2 outgassing could be correlated with CF"4 plasma interface cleaning used for thick SiGe PECVD, which can leave carbon at the CF"4-plasma-cleaned interface.
The fatigue properties of EP539LM alloy with an Al-Nb-Si fused slurry coating and a Co-Cr-Al-Y electron-beam coating are investigated experimentally in vacuum and in air at 900 C. It is found that the protective coatings reduce the fatigue life of the specimens both in vacuum and in air, with the electron-beam coating affecting the fatigue life of the alloy to a lesser degree than the fused slurry coating. The negative effect of the coatings on the fatigue life of the alloy is attributed largely to the properties of the coating material. 7 references.
The main results of earlier work by the author, Sushko, and Khoruzhii describing the algebraic structure of quantum-field systems with (discrete) vacuum superselection rules are generalized to the large class of Wightman theories with essentially self-adjoint field operators (a very strong restriction was imposed on the theory, namely, that the polynomial Op algebra of the Wightman fields /rho/ belongs to the class II, i.e., /rho/ /sub s'/ =/rho/ /sub w'/). It is also shown that the field Op algebra of a Wightman theory with discrete vaccum superselection rule possesses a class II extension.
The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)
If quantum fields exist in extra compact dimensions, they will give rise to a quantum vacuum or Casimir energy. That vacuum energy will manifest itself as a cosmological constant. The fact that supernova and cosmic microwave background data indicate that the cosmological constant is of the same order as the critical mass density to close the universe supplies a lower bound on the size of the extra dimensions. Recent laboratory constraints on deviations from Newton's law place an upper limit. The allowed region is so small as to suggest that either extra compact dimensions do not exist, or their number is about to be tightly constrained by experimental data.
If quantum fields exist in extra compact dimensions, they will give rise to a quantum vacuum or Casimir energy. That vacuum energy will manifest itself as a cosmological constant. The fact that supernova and cosmic microwave background data indicate that the cosmological constant is of the same order as the critical mass density to close the universe supplies a lower bound on the size of the extra dimensions. Recent laboratory constraints on deviations from Newton's law place an upper limit. The allowed region is so small as to suggest that either extra compact dimensions do not exist, or their properties are about to be tightly constrained by experimental data.
The heavy crude fraction processing is performed under very high vacuum to minimize thermal cracking which cause coke deposition and damage the equipment. The current tendency is to process heavier oil leading to higher process temperatures and consequently to greater fouling. This situation demands better knowledge fouling process by carbonization. This problem is pronounced in the residual gasoil region of a vacuum distillation unit because it obstructs the recirculation circuits and the spray system with serious environmental and economics implications. This paper review the main correlated published work related to coke generation and fouling and presents a discussion about the works. (author)
We consider the dynamics toward the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The 'Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.
We consider the dynamics toward the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The 'Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.
We consider the dynamics towards the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The `Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.
The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of instrument combines ...
The transfer function concept is well known as an additional method to evaluate the impulse test of power transformers in the test laboratory. Another application for the transfer function method is monitoring of transformers in service. Thereby, Off-line and On-line monitoring can be realized. Both kinds of monitoring are demonstrated with on-site measurements on a power transformer in service.
Juvenile trees of kalmia derived from shoot tip culture, and seedlings of kobus were irradiated with #gamma#-rays. In kalmia, two mutation lines were obtained which had narrowlong leaves. In kobus two mutation lines were obtained. One mutation line has flowers with 7 to 13 petals. Another mutation line has yellow-green variegated leaves. (author).
Thin films of new metastable materials from the system Ti-B-C-N were deposited on metallic substrates by d.c. magnetron sputtering in different Ar+N{sub 2} atmospheres. The multiphase compound targets used were based on various compositions on the TiC-TiB{sub 2} and TiB{sub 2}-C tie lines of the Ti-B-C phase diagram. The structure and chemical composition of the films were characterized by electron microprobe analysis, depth profiling Auger electron spectroscopy, X-ray diffraction and transmission electron microscopy. The hardness, critical load of failure and the tribological behavior of the coatings were investigated. Superhard single-phase crystalline metastable Ti-B-C-N layers with hardness values exceeding 5000 HV{sub 0.05} and extremely low sliding wear against 100Cr6 and Al{sub 2}O{sub 3} counterparts could be produced by reactive sputtering of various TiC-TiB{sub 2} targets in Ar+N{sub 2} atmospheres with low nitrogen flows. In the case ...
Since 1994-95 the University of Applied Sciences Berne is working on weather-proof electric bicycles. The main drawbacks of bicycles, no weather-protection, little comfort of the saddle, the difficulty of climbing hills, are to be eliminated. The electro-mechanical drive-train of 'Ultraleichtmobil ULM BE 2000', developed in 1995-96, was mechanically complicated. This resulted in reduced energy-efficiency and intense maintenance. Too, the drive-train was expensive in production. A fully electrical human-power transmission seemed to be the solution to the problems mentioned above. It is appealing not only to the user of the vehicle, but also to the producer and to the persons doing the maintenance. Following an internal study showing the technical feasibility of such an electrical transmission, a controllable DC/DC-converter which allows to operate a pedal-driven generator at maximum efficiency has been developed. The electrical ...
A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into the metallic sheath, outer conductor and armoring at the bonding points. Analytical results for the ...
This document presents the proceedings of the Areva technical days, presented during the session 5 the 9 and 10 december 2004, at Istanbul. It deals with the operations of the transmission and distribution division. With manufacturing facilities in over 40 countries and a sales network in over 100, Areva offers customers technological solutions for nuclear power generation and electricity transmission and distribution (the Group also provides interconnect systems to the telecommunications, computer and automotive markets). It provides five topics: a general presentation of Areva, the strategic stakes for transmission and distribution by world-zone, economic and strategic stakes of business unit products, business unit systems and business unit automation. (A.L.B.)
A detailed examination of the aging processes that may take place in solid-dielectric extruded-type high voltage transmission cables under dry conditions is presented. Particular emphasis is placed on the aging process as affected by the separate and simultaneous action of four main aging factors, namely the electrical, mechanical and thermal stresses, and the physical and chemical environment. A number of pertinent aging models are considered and their validity and applicability to accelerated aging tests on solid-type transmission cables are discussed.
An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are ...
We investigate opportunistic cooperation between unlicensed secondary users and legacy primary users in a cognitive radio network. Specifically, we consider a model of a cognitive network where a secondary user can cooperatively transmit with the primary user in order to improve the latter's effective transmission rate. In return, the secondary user gets more opportunities for transmitting its own data when the primary user is idle. This kind of interaction between the primary and secondary users is different from the traditional dynamic spectrum access model in which the secondary users try to avoid interfering with the primary users while seeking transmission opportunities on vacant primary channels. In our model, the secondary users need to balance the desire to cooperate more (to create more transmission opportunities) with the need for maintaining sufficient energy levels for their own ...
Schizophrenia is a heterogeneous psychiatric disorder in which multiple neurotransmitter systems have been implicated. Increased and decreased dopamine transmission in the subcortical meso-limbic and...Full Text Available
BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available
BackgroundMalaria is one of the most important tropical diseases that affects people globally. The influence of environmental conditions in the patterns of temporal distribution...Full Text Available
BackgroundIt is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission...Full Text Available
Summary 1.-The presence of Brucella abortus within free-ranging wildlife populations is an important conservation and management issue because of the risk of brucellosis transmission between wildlife and livestock. Predicting wildlife distributions is necessary to forecast wildlife and livestock spatial overlap and the potential for brucellosis transmission. 2.-We used Global Positioning System data collected from telemetry-collared female elk Cervus elaphus to develop resource selection function (RSF) models during the brucellosis transmission risk period (the abortion and calving periods). We validated extrapolation of predictive models at two nearby elk ranges within the Greater Yellowstone Ecosystem. Additionally, we integrated extrapolated RSF maps and domestic livestock distributions...
The symposium reviewed the use of electronics in mining today. Subjects covered include control systems; remote sensing; telemetry; data transmission; microprocessors and transportation systems. 15 papers have been abstracted separately.
Recently, independent system operators (ISOs) and others have published reports on the costs of transmission congestion. The magnitude of congestion costs cited in these reports has contributed to the national discussion on the current state of U.S. electricity transmission system and whether it provides an adequate platform for competition in wholesale electricity markets. This report reviews reports of congestion costs and begins to assess their implications for the current national discussion on the importance of the U.S. electricity transmission system for enabling competitive wholesale electricity markets. As a guiding principle, we posit that a more robust electricity system could reduce congestion costs; and thereby, (1) facilitate more vibrant and fair competition in wholesale electricity markets, and (2) enable consumers to seek out the lowest prices for electricity. Yet, examining the details suggests that, ...
Contact precautions are implemented to reduce transmission of multidrug-resistant organisms but may also increase hospital costs and patient complications. The goal of this study was to determine...Full Text Available
BackgroundThere is no data documenting the existence of a risk of infection transmission in ambulatory healthcare settings but concern remains. Our objective was to determine the...Full Text Available
The pleiotropic actions of neuromodulators on pre- and postsynaptic targets present challenges to disentangling the mechanisms underlying regulation of synaptic transmission. Within the striatum,...Full Text Available
Aerosol particles are ubiquitous in the troposphere and exert an important influence on global climate and the environment. They affect climate through scattering, transmission, and absorption of...Full Text Available
Restructuring of power system has changed the traditional planning objectives and introduced challenges in the field of Transmission Expansion Planning (TEP). Due to these changes, new approaches and criteria are needed for transmission planning in deregulated environment. Therefore, in this paper, a dynamic expansion methodology is presented using a multi-objective optimization framework. Investment cost, congestion cost and reliability are considered in the optimization as three objectives. To overcome the difficulties in solving the non-convex and mixed integer nature of the optimization problems, a Non-Dominated Sorting Genetic Algorithm (NSGA II) approach is used followed by a fuzzy decision making analysis to obtain the final optimal solution. The planning methodology has been demonstrated on the IEEE 24-bus test system and north-east of Iran national 400 kV transmission grid to show the feasibility and capabilities ...
Emission-line abundances have been uncertain for more than a decade due to unexplained discrepancies in the relative intensities of the forbidden lines and weak permitted recombination lines in planetary nebulae (PNe) and H II regions. The observed intensities of forbidden and recombination lines originating from the same parent ion differ from their theoretical values by factors of more than an order of magnitude in some of these nebulae. In this study we observe UV resonance line absorption in the central stars of PNe produced by the nebular gas, and from the same ions that emit optical forbidden lines. We then compare the derived absorption column densities with the emission measures determined from ground-based observations of the nebular forbidden lines. We find for our sample of PNe that the collisionally excited forbidden ...
A Vacuum Circuit Breaker demonstrated its ability to interrupt short circuits with faster than normal rates of rise of Transient Recovery Voltage (TRV) at levels greater than those produced by most transformer secondary faults. Two recent exploratory test programs evaluated the interrupting ability of a 15kV Vacuum Circuit Breaker containing interrupters of the rotating arc type with contacts made from a Chromium-Copper powder metal mixture. The interrupting conditions covered a wide range of currents from 10% to 130% of the 28kA rated short circuit current of the tested circuit breaker and a wide range of TRV rates of rise, including the relatively slow rate of rise, normally used in testing and found in most indoor circuit breaker applications; two faster rates of rise equaling and exceeding those found in a known power plant transformer secondary protection application; and the fastest rates of rise possible in the laboratory which exceed ...
The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance ...
Puffer gas circuit breaker used widely in interrupters with from middle capacity to large capacity does not keep away from reacting force of the puffer with high functions in principle and there is a limit in low operation. In this study, aiming at low operation of the interrupters, in order to clarify the basic motions of hybrid circuit interrupter that is the combination of thermal puffer gas circuit breaker and vacuum circuit breaker, the interrupting ability of simple thermal puffer gas breaker and the voltage sharing characteristics in the cases of series connection with the vacuum circuit breaker are studied. The results of the study are as follows. In comparing terminal short circuit accident interrupting ability of single flow typed thermal puffer gas breaker with that of double flow typed thermal puffer gas breaker, the interrupting ability of the double flow typed thermal puffer gas breaker may be improved. It is also clarified that ...
Background/Purpose: Peripherally inserted central venous catheters (PICCs) are commonly used for neonatal vascular access. The aim of this study was to look at PICC line complication rates and possible predictors of PICC infection in a neonatal intensive care unit. Method: This was a prospective study of 226 neonates who had PICCs on our neonatal intensive care unit between January 2006 and June 2009. Complete data was available on 218 neonates who had 294 PICC lines. Criteria for catheter-related sepsis was positive blood cultures (peripheral/central) and/or a positive catheter tip culture after removal in the presence of a clinical suspicion of line sepsis. Results: Of 218 neonates, 132 (169 lines) were medical, and 86 (125 lines) were surgical. Our PICC line infection rate was 17 infect...
Substantially genetically stable continuous human cell lines derived from normal human mammary epithelial cells (HMEC) and processes for making and using the same. In a preferred embodiment, the cell lines are derived by treating normal human mammary epithelial tissue with a chemical carcinogen such as benzo(a)pyrene. The novel cell lines serve as useful substrates for elucidating the potential effects of a number of toxins, carcinogens and mutagens as well as of the addition of exogenous genetic material. The autogenic parent cells from which the cell lines are derived serve as convenient control samples for testing. The cell lines are not neoplastically transformed, although they have acquired several properties which distinguish them from their normal progenitors. 2 tabs.
In the CLIC main linac it is very important to minimise the trajectory excursion and consequently the emittance dilution in order to obtain the required luminosity. Several algorithms have been proposed and lately the ballistic method has proved to be very effective. The trajectory method described in this Note retains the main advantages of the latter while adding some interesting features. It is based on the separation of the unknown variables like the quadrupole misalignments, the offset and slope of the injection straight line and the misalignments of the beam position monitors (BPM). This is achieved by referring the trajectory relatively to the injection line and not to the average pre-alignment line and by using two trajectories each corresponding to slightly different quadrupole strengths. A reference straight line is then derived onto which the beam is bent by a kick obtained by moving the ...
Lunar resource utilization has focused principally on the extraction of oxygen from the lunar regolith. A number of schemes have been proposed for oxygen extraction from Ilmenite and Anorthite. Serendipitously, these schemes have as their by-products (or more directly as their "waste products"), materials needed for the fabrication of thin film silicon solar cells. Thus lunar surface possesses both the elemental components needed for the fabrication of silicon solar cells and a vacuum environment that allows for vacuum deposition of thin film solar cells directly on the surface of the Moon without the need for vacuum chambers. In support of the US space exploration initiative a new architecture for the production of thin film solar cells on directly on the lunar surface is proposed. The paper discusses experimental data on the fabrication and properties of lunar glass substrates, evaporated lunar regolith thin films ...
We revisited the quantum Zeno paradox, which claims that a generic quantum system prepared in a state which is not an eigenstate of the Hamiltonian operator and is continuously observed never decays. Since any perfectly isolated quantum system always interact with a vacuum field, we analyze the possibility of using this fact to solve the above mentioned conceptual problem. Therefore we discuss a two-level system or qubit-Bose field interaction Hamiltonians. We consider the quantum dynamics of this two-level system, prepared in the excited state interacting with a Bose field prepared in the Poincare invariant vacuum state. Using a first-order approximation in time-dependent perturbation theory, we evaluate the probability of spontaneous decay of the two-level system driven by the vacuum field. This probability is evaluated for a finite time interval. Using the standard argument to obtain the quantum Zeno paradox, we consider ...
Potassium deposition in ultrahigh vacuum on 12-(3-thienyl)dodecanethiol monolayers assembled on gold surfaces has been investigated using X-ray and ultraviolet photoelectron spectroscopies (XPS and UPS). Angle-resolved XPS indicates that initially deposited potassium penetrates the self-assembled monolayer (SAM) and diffuses to the SAM/Au interface. Even after large metal doses, the presence of thiophene ring valence electronic states in the UPS spectra confirms that most of the thiophene rings (at the SAM/vacuum interface) are not covered by potassium. The binding energy shifts of the thiophene ring valence states and the C1s and thiophene S2p peaks, referenced to the Fermi level, are due to the work function changes of the gold substrate. This indicates that these electronic states are pinned to the vacuum level, in contrast to the thiolate S2p orbital, which is pinned to the Fermi level. For large potassium doses, the ...
Aiming to realize ball bearings operable in a vacuum and under high temperature, silicon nitride (Si3N4) ceramic ball bearings were tested. The tested ball bearings were angular contact ball bearings composed of silicon nitride with sputtered molybdenum disulfide coating using a retainer of hot-pressed self-lubricating composite material. The time variation of the frictional torque was examined for the operations under the conditions at 500{degree}C in a vacuum at a rotational speed of 600 rpm and 50N thrust load for 5{times}10{sup 7}revolutions (1400 hours) and for 1.5{times}10{sup 8}revolutions (4200 hours). Excellent tribological performance was obtained. The ball bearings are lubricated with the molybdenum disulfide film at the initial stage of the operation and with a transfer film formed from the retainer material to the balls. In a test at 650{degree}C, low and stable frictional torque was observed up to 500 hours of operation as of the ...
In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify the magnitude of the plasma rotation. It is found that at the ...
The decays of charmed mesons into two body nonleptonic final states are investigated. Weak interaction amplitudes of interest in these decays are extracted from lattice four-point correlation functions using a effective weak Hamiltonian including effects to order G{sub f} in the weak interactions yet containing effects to all orders in the strong interactions. The lattice calculation allows a quantitative examination of non-spectator processes in charm decays helping to elucidate the role of effects such as color coherence, final state interactions and the importance of the so called weak annihilation process. For D {yields} K{pi}, we find that the non-spectator weak annihilation diagram is not small, and we interpret this as evidence for large final state interactions. Moreover, there is indications of a resonance in the isospin {1/2} channel to which the weak annihilation process contributes exclusively. Findings from the lattice calculation are compared to results from the continuum ...
The dependencies that limit high frequency operation of a vacuum microelectronic grating free-electron laser are examined. The important parameters are identified as the electron beam energy, emittance, and generalized perveance. The scaling of power with emittance and frequency is studied in the far-infrared spectral range using a modified scanning electron microscope (SEM) and submillimeter diffraction gratings. The SEM is suited to the task of generating and positioning a low emittance (10"-"2#pi#-mm-mrad), low current (100 #mu#A), but high current density (50-500 A cm"-"2) electron beam. It has been used to demonstrate the spontaneous emission process known as the Smith-Purcell effect. A vacuum microelectronic grating free-electron laser has the potential of generating radiation throughout the entire far-infrared spectral range which extends from approximately 10 to 10"3#mu#m. An introduction to the theory, initial results, and details of ...
SummaryBackgroundInnovative prevention strategies for HIV-1 transmission are urgently needed. PRO2000 vaginal gel was efficacious against HIV-1 transmission in studies...Full Text Available
The demands made on data transmission systems by modern mining companies are used to show why the currently used multiplexers cannot satisfy future requirement. The telecommunications department of Bergbau-Forschung GmbH is now developing a telecommunication system for underground work. The requirements made on this system are reported.
A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.
This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.
SiO{sub 2}, TiO{sub 2} and AlO(OH) powders obtained by the sol-gel method were investigated by transmission electron microscopy. The mass-radius relation was used to determine the fractal dimensions from the images. These fractal dimensions were corrected in order to obtain the powder fractal dimensions. The results indicate a good fractal behavior and high fractal dimensions.
A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)
Recent development in application of a focused ion beam (FIB) technique to preparation of thin foil specimens for transmission electron microscopy (TEM) observation has been reviewed. Combined technique of FIB/TEM enables one to analyze those microstructures which have been almost impossible or very difficult to analyze so far. (author)
Gonadotropin–releasing hormone (GnRH) neurons are the central regulators of reproduction. GABAergic transmission plays a critical role in pubertal activation of pulsatile GnRH secretion....Full Text Available
For almost 150 years, the two monotypic genera Trochodendron and Tetracentron (Trochodendraceae) have been considered to share an unusual and primitive feature in angiosperms - the lack of vessels in their wood. Therefore, they have been classified in a basal position in the angiosperms. Our observations by light microscopy, low-vacuum environmental scanning electron microscopy (ESEM) and high-vacuum scanning electron microscopy (SEM) both in fresh and FAA-fixed materials consistently showed the presence of tracheary elements differentiated into two types in both genera. In Trochodendron, the tracheary elements can be divided into perforate vessel elements and imperforate fiber-tracheids and tracheids. The vessel elements show end and lateral walls. The pits on the end walls are elongate- ...
During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and ...
We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a stable cation.
We study a two-level atom in interaction with a real massless scalar quantum field in a spacetime with a reflecting boundary. The presence of the boundary modifies the quantum fluctuations of the scalar field, which in turn modifies the radiative properties of atoms. We calculate the rate of change of the mean atomic energy of the atom for both inertial motion and uniform acceleration. It is found that the modifications induced by the presence of a boundary make the spontaneous radiation rate of an excited inertial atom oscillate near the boundary and this oscillatory behavior may offer a possible opportunity for experimental tests for geometrical (boundary) effects in flat spacetime. While for accelerated atoms, the transitions from ground states to excited states are found to be possible even in a vacuum due to changes in the vacuum fluctuations induced by both the presence of the boundary and the acceleration of atoms, and this can be ...
The light-emitting properties of cubic silicon carbide films grown by vacuum vapor phase epitaxy on Si(100) and Si(111) substrates under conditions of decreased growth temperatures (T gr ? 900?700?C) have been discussed. Structural investigations have revealed a nanocrystalline structure and, simultaneously, a homogeneity of the phase composition of the grown 3C-SiC films. Photoluminescence spectra of these structures under excitation of the electronic subsystem by a helium-cadmium laser (?excit = 325 nm) are characterized by a rather intense luminescence band with the maximum shifted toward the ultraviolet (?3 eV) region of the spectral range. It has been found that the integral curve of photoluminescence at low temperatures of measurements is split into a set of Lorentzian components. Th...
For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).
The present article will review recent advances in focused ion beam (FIB) technology. With increasing demands for scale of integration, microfabrication technology is becoming more important and various new microfabrication tools and processing techniques are desired. FIB is one of the promising tools for future microfabrication technology. This provides maskless patterning capability, which is of importance for process simplification, nanofabrication and in the development of in situ vacuum processing. In situ vacuum processing systems are being developed by combining FIB and a molecular beam epitaxy system. Radiation damage may limit applications of FIB. However, it was demonstrated that low energy FIB (<1 keV) with very high brightness was reached and promising results for low damage processing have been obtained. (orig.).
Twelve powders of TiO_2-Y_2O_3-ZrO_2 solid solution of the methodically changed composition were prepared by a coprecipitation-calcination technique. After mixing with phenol-formaldehyde resin, the powders were calcinated for 2 hours at 1200"oC in vacuum. The resultant composite powders contained TiC and non-reacted carbon. Green compacts were sintered in vacuum at 1500"oC for 2 hours. A temperature increase was stopped at 1200"oC to react remains of carbon. There were two carbides in the composites TiC and ZrC. TiC non-stoichiometry depended on carbon content in the system. Phase composition of the depended on of titania and yttria in zirconia solid solution. The majority of the samples showed two tetragonal zirconia phases differing in lattice parameter and tetragonality. (author)
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-electrode gap, i.e. in the vicinity of the Paschen minimum. In this area of pressure and inter-electrode gap values, breakdown occurs either through gas or vacuum mechanisms, and also the so called anomalous Paschen effect appears. Electrical breakdown of electropositive, electronegative and noble gases has been investigated theoretically, experimentally and numerically. Based on the results obtained, regions in which particular breakdown mechanisms appear have been demarcated. Special attention has been devoted to the anomalous Paschen effect as well as to the avalanche vacuum breakdown mechanism.
This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-electrode gap, i.e. in the vicinity of the Paschen minimum. In this area of pressure and inter-electrode gap values, breakdown occurs either through gas or vacuum mechanisms, and also the so called anomalous Paschen effect appears. Electrical breakdown of electropositive, electronegative and noble gases has been investigated theoretically, experimentally and numerically. Based on the results obtained, regions in which particular breakdown mechanisms appear have been demarcated. Special attention has been devoted to the anomalous Paschen effect as well as to the avalanche vacuum breakdown mechanism.
Within the framework of the Bianchi type-IX homogeneous space, we set up a system of coupled equations for the cosmic scale factors, scalar field, and radiative energy density. At the tree level, the equations are written in a self-consistent, Hartree-Fock form. For phi/sup 4/ theory, the system of nine first-order differential equations is solved numerically for a varying ratio of the energy of anisotropy to the vacuum energy. As the vacuum energy increases, there appears to be less reheating, since the energy of anisotropy is more efficiently converted into isotropic expansion. If the energy of anisotropy is large enough, the inflationary phase is prevented. In this case, a series of cosmological phase transitions will take place each time the square of the effective mass changes its sign.
Within the framework of the Bianchi type-IX homogeneous space, we set up a system of coupled equations for the cosmic scale factors, scalar field, and radiative energy density. At the tree level, the equations are written in a self-consistent, Hartree-Fock form. For phi"4 theory, the system of nine first-order differential equations is solved numerically for a varying ratio of the energy of anisotropy to the vacuum energy. As the vacuum energy increases, there appears to be less reheating, since the energy of anisotropy is more efficiently converted into isotropic expansion. If the energy of anisotropy is large enough, the inflationary phase is prevented. In this case, a series of cosmological phase transitions will take place each time the square of the effective mass changes its sign.
We review various field theory approaches to the description of neutrino oscillations in vacuum and external fields. First we discuss a relativistic quantum mechanics based approach which involves the temporal evolution of massive neutrinos. To describe the dynamics of the neutrinos system we use exact solutions of wave equations in presence of an external field. It allows one to exactly take into account both the characteristics of neutrinos and the properties of an external field. In particular, we examine flavor oscillations an vacuum and in background matter as well as spin flavor oscillations in matter under the influence of an external electromagnetic field. Moreover we consider the situation of hypothetical nonstandard neutrino interactions with background fermions. In the case of ultrarelativistic particles we reproduce an effective Hamiltonian which is used in the standard quantum mechanical approach for the description of neutrino ...
By assuming that not only counter-ions but DNA molecules as well are thermally distributed according to a Boltzmann law, we propose a modified Poisson-Boltzmann equation, at the classical level, as a starting point to compute the effects of quantum fluctuations of the electric field on the interaction among DNA-cation complexes. The latter are modeled here as infinite one-dimensional wires (?-functions). Our goal is to single out such quantum-vacuum-driven interaction from the counterion-induced and water-related interactions. We obtain a universal, frustration-free Casimir-like (codimension 2) interaction that extensive numerical analysis show to be a good candidate to explain the formation and stability of DNA aggregates. Such Casimir energy is computed for a variety of configurations of...
Using the infrared spectroscopy method, we have studied the effect of thermal dehydration (under vacuum and in air) and treatment with water vapor on the acid centers of very high silicon zeolites of the ZSM type. We have shown that dehydration under vacuum and in air completely and irreversibly removes the OH groups at 1120/sup 0/K, while treatment with water vapor removes these groups at 770/sup 0/K. The Lewis acid centers of dehydrated zeolites (represented by two types of centers) are more heat-stable than the Bronsted acid centers, but the vapor treatment at 1020/sup 0/K leads to the disappearance of the Lewis acid centers. In this work, we discuss the reasons for destruction of the acid centers of the zeolites under different treatment conditions.
Disorder on the string theory landscape may significantly affect dynamics of eternal inflation leading to the possibility for some vacua on the landscape to become dynamically preferable over others. We systematically study effects of a generic disorder on the landscape starting by identifying a sector with built-in disorder -- a set of de Sitter vacua corresponding to compactifications of the Type IIB string theory on Calabi-Yau manifolds with a number of warped Klebanov-Strassler throats attached randomly to the bulk part of the Calabi-Yau. Further, we derive continuum limit of the vacuum dynamics equations on the landscape. Using methods of dynamical renormalization group we determine the late time behavior of the probability distribution for an observer to measure a given value of the cosmological constant. We find the diffusion of the probability distribution to significantly slow down in sectors of the landscape where the number of nearest neighboring vacua ...
We investigate the quantum cosmology of spatially homogeneous models with compact spatial sections admitting a u(2) isometry algebra. The metric ansatz in these models is that of Bianchi type IX with two scale factors set to be equal. We apply the Hartle-Hawking no-boundary path integral prescription and find the semi-classical contributions to the wave function. Exact formulae are obtainable for certain contributions and otherwise the limits of large and small anisotropy (for the pure vacuum case) and large spatial volume or small anisotropy (for the case with a positive cosmological constant) are considered. For the pure vacuum case we find no semiclassical components which would correspond to Lorentzian universes. For the case with a cosmological constant the Hartle-Hawking boundary conditions formally constrain one of the parameters in the Lorentzian solutions to be purely imaginary. Possible interpretations of this imaginary parameter are ...
We investigate the quantum cosmology of spatially homogeneous models with compact spatial sections admitting a u(2) isometry algebra. The metric ansatz in these models is that of Bianchi type IX with two scale factors set to be equal. We apply the Hartle-Hawking no-boundary path integral prescription and find the semi-classical contributions to the wave function. Exact formulae are obtainable for certain contributions and otherwise the limits of large and small anisotropy (for the pure vacuum case) and large spatial volume or small anisotropy (for the case with a positive cosmological constant) are considered. For the pure vacuum case we find no semiclassical components which would correspond to Lorentzian universes. For the case with a cosmological constant the Hartle-Hawking boundary conditions formally constrain one of the parameters in the Lorentzian solutions to be purely imaginary. Possible interpretations of this imaginary parameter are ...
The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.
The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.
We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.