WorldWideScience
 
 
4

Lens-induced glaucoma in the elderly  

UK PubMed Central (United Kingdom)

Lens-induced glaucoma comprises a number of different glaucomatous processes occurring in the elderly that share in common the role of the crystalline lens in the mechanism of increase in intraocular...Full Text Available

2009-01-01

5

Visual and refractive outcome of one-site phacotrabeculectomy compared with temporal approach phacoemulsification  

UK PubMed Central (United Kingdom)

BackgroundWe aimed to compare visual and refractive outcome following phacoemulsification and intraocular lens implant (IOL) and combined one-site phacotrabeculectomy.MethodWe...Full Text Available

2008-09-01

6

Long-term results of extracapsular cataract extraction and posterior chamber intraocular lens insertion in Nepal.  

UK PubMed Central (United Kingdom)

We performed a prospective study evaluating the 2-year success rate of extracapsular cataract surgery and posterior chamber IOL insertion performed in 610 eyes by an experienced surgeon in the Nepal...Full Text Available

1991-01-01

7

Ultraviolet-B Phototoxicity and Hypothetical Photomelanomagenesis: Intraocular and Crystalline Lens Photoprotection  

British Library Electronic Table of Contents (United Kingdom)

Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...

2010-01-01

8

Vitrectomy Timing for Retained Lens Fragments After Surgery for Age-Related Cataracts: A Systematic Review and Meta-Analysis  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate the effect of vitrectomy timing on outcomes for patients with crystalline retained lens fragments receiving vitrectomy 3+ days after cataract surgery. DesignSystematic review and meta-analysis of retrospective interventional cases series. MethodsSearches of MEDLINE (English, 1/1/85 through 7/30/2010) and article reference lists. Articles were screened for patients with crystalline retained lens fragments after surgery for age-related cataracts, discussion of vitrectomy timing, and, for the meta-analysis, patient totals for at least 1 outcome and multiple time periods, 10+ patients, and mean follow-up ?3 months. Outcomes included visual acuity, retinal detachment, increased intraocular pressure, intraocular infection/inflammation, cystoid macular edema, and corneal...

2011-01-01

9

Phacoemulsification and customized toric intraocular lens implantation in eyes with cataract and high astigmatism after penetrating keratoplasty  

British Library Electronic Table of Contents (United Kingdom)

Financial DisclosurePhacoemulsification and implantation of a hydrophilic acrylic toric intraocular lens (IOL) (T-flex 623T) with customized cylindrical power was performed in 1 eye in 3 consecutive patients with cataract and high postkeratoplasty astigmatism (range 6.75 to 8.75 diopters [D]). Twelve months postoperatively, the uncorrected distance visual acuity improved from 20/200 to 20/30 in Case 1, from 20/400 to 20/40 in Case 2, and from 20/200 to 20/25 in Case 3 and the corrected distance visual acuity was 20/25 or better in all 3 eyes. The spheroequivalent was within +-0.50 D of the intended value and the refractive astigmatism was less than 1.00 D. The corneal grafts were transparent, and the endothelial cell loss range was 6% to 12%. Rotation of the toric IOL was less than 5 degre...

2011-01-01

10

Intraocular coenurosis: a case report.  

UK PubMed Central (United Kingdom)

A case of intraocular coenurosis was clinically diagnosed and treated with praziquantel. The drug destroyed the coenurus, but vision was lost through toxic endophthalmitis and retinal detachment. There...Full Text Available

1991-07-01

15

Effects of Sildenafil and Tadalafil on Intraocular Pressure in Sheep: Implications for Aqueous Humor Dynamics  

UK PubMed Central (United Kingdom)

Purpose.To determine the effects of vasodilators on intraocular pressure (IOP) and the protein content of sheep aqueous humor (AH), because the vasodilators may increase fluid leakage...Full Text Available

2010-06-01

16

Post-lens tear-film depletion due to evaporative dehydration of a soft contact lens  

British Library Electronic Table of Contents (United Kingdom)

For a soft-contact-lens (SCL) wearer, corneal health and comfort are strongly influenced by water transport through the polymeric materials used in lens fabrication. In particular, evaporative water loss at the anterior lens surface is a potential cause of contact-lens dehydration and of post-lens tear-film depletion, which in turn, may lead to discomfort, dryness syndrome, and/or lens adhesion.We present a solution-diffusion model for transport of water through soft-contact-lens materials to mimic evaporative dehydration from a contact lens during blinking and to access possible SCL adhesion to the corneal surface under a variety of environmental conditions (e.g., wind speed and relative humidity). To describe the water-transport process, we use an extended version of the Maxwell-Stefan m...

2006-01-01

17

Acoustic transducer for acoustic microscopy  

Energy Technology Data Exchange (ETDEWEB)

A shear acoustic transducer-lens system in which a shear polarized piezoelectric material excites shear polarized waves at one end of a buffer rod having a lens at the other end which excites longitudinal waves in a coupling medium by mode conversion at selected locations on the lens.

1990-01-01

18

Aphakic macular oedema following prosthetic lens implantation.  

UK PubMed Central (United Kingdom)

Fluorescein angiography of the iris was performed on patients with plastic lens implants with cystoid oedema of the macula, and the nature of the vascular changes was compared with controls provided...Full Text Available

1977-05-01

20

Clinical and experimental studies of octocrylene's allergenic potency  

British Library Electronic Table of Contents (United Kingdom)

Background. Reports of positive patch test and photopatch test reactions to the chemical ultraviolet filter octocrylene have increased during the last decade. Little is known about the reason for octocrylene's allergenic activity. Objectives. To present and discuss the results of patch tests and photopatch tests with octocrylene, and to investigate the possible cause of its allergenic properties. Methods. Results of patch tests and photopatch tests with octocrylene in patients with adverse skin reactions to sunscreen products and/or ketoprofen were collected. The allergenic potency of octocrylene was investigated in the murine local lymph node assay (LLNA). Chemical reactivity assays were used to mimic octocrylene's interaction with biomolecules. Results. We report 23 cases of positive tes...

2011-01-01

 
 
 
 
21

Topically administered timolol and dorzolamide reduce intraocular pressure and protect retinal ganglion cells in a rat experimental glaucoma model  

UK PubMed Central (United Kingdom)

Aims: This study sought to elucidate the effects of timolol and dorzolamide on intraocular pressure (IOP) and retinal ganglion cell (RGC) death in an experimental...Full Text Available

2005-04-01

22

Outcome of in-the-bag implanted square-edge polymethyl methacrylate intraocular lenses with and without primary posterior capsulotomy in pediatric traumatic cataract  

UK PubMed Central (United Kingdom)

Purpose:To study the outcome of in-the-bag implanted square-edge polymethyl methacrylate (PMMA) intraocular lenses (IOL) with and without primary posterior capsulotomy in...Full Text Available

2011-09-01

23

Manufacture of PLZT Bonded Lens Assemblies.  

Science.gov (United States)

Two manufacturing processes have been developed for fabricating PLZT bonded lens assemblies (BLA's) for the USAF EEU-2/P Thermal/Flash Protective Goggle. One process utilizes thin Sylgard spacers which remain in the BLA to establish bond thickness between...

1979-01-01

24

Immunochemical detection of glycated lens crystallins and their circulating autoantibodies in human serum during aging  

UK PubMed Central (United Kingdom)

PurposeThe aim of this investigation was to exploit lens-specific glycated crystallins as an immunogen to detect human glycated crystallins and their circulating autoantibodies in...Full Text Available

25

Analysis on the alterations of lens proteins by Vitex negundo in selenite cataract models  

UK PubMed Central (United Kingdom)

PurposeCataract is the leading cause of blindness and is associated with oxidative damage and protein modification in the lens. In the present study, we have employed proteomic and...Full Text Available

27

H-1152 Effects on Intraocular Pressure and Trabecular Meshwork Morphology of Rat Eyes  

UK PubMed Central (United Kingdom)

AbstractPurposeThe aim of this study was to elucidate the effects of the Rho-kinase inhibitor, H-1152, on cultured human trabecular meshwork (HTM) cells, TM morphology,...Full Text Available

2008-08-01

28

Frequency of ocular metastases in patients dying of cancer in eye bank populations.  

UK PubMed Central (United Kingdom)

AIMS: To examine the frequency of intraocular metastases in patients who had died of cancer, in an eye bank and necropsy population sample. METHODS: The first group included 302 cancer cases received...Full Text Available

1996-02-01

29

Plasma lens formation in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).

1995-02-01

30

Dual focal point electro-optic lens with a Fresnel-zone plate on a PLZT ceramic.  

Science.gov (United States)

A new dual focal point electro-optic lens that is switchable to focusing and unfocusing is proposed and successfully demonstrated. This electro-optic lens is constructed by coating transparent fine electrodes in the Fresnel-zone plate onto a PLZT ceramic plate. Its focal length changes from 1.25 m to infinity binary at 515 nm with the external voltage of 210 V. PMID:20725208

1992-05-20

31

International Lens Design Conference, Monterey, CA, June 11-14, 1990, Proceedings  

Energy Technology Data Exchange (ETDEWEB)

The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of ...

1990-01-01

32

HINS Linac front end focusing system R&D  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes current status of an R&D program to develop a focusing system for the front end of a superconducting RF linac. Superconducting solenoids will be used as focusing lenses in the low energy accelerating sections of the front end. The development of focusing lenses for the first accelerating section is in the production stage, and lens certification activities are in preparation at FNAL. The report contains information about the focusing lens design and performance, including solenoid, dipole corrector, and power leads, and about cryogenic system design and performance. It also describes the lens magnetic axis position measurement technique and discusses scope of an acceptance/certification process.

2008-08-01

33

Possible applications of plasma lens in high energy physics  

Energy Technology Data Exchange (ETDEWEB)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition {ital k}{sub {ital p}}{sigma}{sub {ital x}}{approx_gt}1, and not {ital k}{sub {ital p}}{sigma}{sub {ital y}}{approx_gt}1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for {gamma}{gamma} colliders is discussed.{copyright}{ital American Institute of Physics.}

1996-01-01

34

Possible applications of plasma lens in high energy physics  

International Nuclear Information System (INIS)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition k_p#sigma#_x approx-gt 1, and not k_p#sigma#_y approx-gt 1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for #gamma##gamma# colliders is discussed.copyright American Institute of Physics.

35

NI\\S/\\ - NASA Technical Report Server (NTRS)  

Science.gov (United States)

The first point in the learning curve has been obtained. REFERENCES ..... Lens 4 is selected such that l/fl=1/f4+1/x, where x is ...

36

Gravitational Lens Modeling with Genetic Algorithms and Particle Swarm Optimizers  

CERN Document Server

Strong gravitational lensing of an extended object is described by a mapping from source to image coordinates that is nonlinear and cannot generally be inverted analytically. Determining the structure of the source intensity distribution also requires a description of the blurring effect due to a point spread function. This initial study uses an iterative gravitational lens modeling scheme based on the semilinear method to determine the linear parameters (source intensity profile) of a strongly lensed system. Our 'matrix-free' approach avoids construction of the lens and blurring operators while retaining the least squares formulation of the problem. The parameters of an analytical lens model are found through nonlinear optimization by an advanced genetic algorithm (GA) and particle swarm optimizer (PSO). These global optimization routines are designed to explore the parameter space thoroughly, mapping model degeneracies in ...

2011-01-01

37

Role of cerebrospinal fluid pressure in the pathogenesis of glaucoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract. The pathogenesis of normal (intraocular) pressure glaucoma has remained unclear so far. As hospital-based studies showed an association of normal-pressure glaucoma with low systemic blood pressure, particularly at night, and with vasospastic symptoms, it has been hypothesized that a vascular factor may play a primary role in the pathogenesis of normal-pressure glaucoma. That assumption may, however, be contradicted by the morphology of the optic nerve head. Eyes with normal-pressure glaucoma and glaucomatous eyes with high-intraocular pressure can show a strikingly similar appearance of the optic nerve head, including a loss of neuroretinal rim, a deepening of the optic cup, and an enlargement of parapapillary atrophy. These features, however, are not found in any (other) vascula...

2011-01-01

38

Activation of Metallothioneins and ?-Crystallin/sHSPs in Human Lens Epithelial Cells by Specific Metals and the Metal Content of Aging Clear Human Lenses  

UK PubMed Central (United Kingdom)

PurposeTo identify those metallothionein and α-crystallin/small heat-shock genes induced by toxic metals in human lens cells and to evaluate...Full Text Available

2003-02-01

39

Ultraviolet radiation for the sterilization of contact lenses  

Energy Technology Data Exchange (ETDEWEB)

Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens ...

1990-10-01

40

Ultraviolet radiation for the sterilization of contact lenses  

International Nuclear Information System (INIS)

Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens ...

 
 
 
 
41

High channel density wavelength division multiplexer with defined diffracting means positioning  

Energy Technology Data Exchange (ETDEWEB)

A wavelength division multiplexer/demultiplexer having optical path lengths between a fiber array and a Fourier transform lens, and between a dispersion grating and the lens equal to the focal length of the lens. The optical path lengths reduce losses due to angular acceptance mismatch in the multiplexer. Close orientation of the fiber array about the optical axis and the use of a holographic dispersion grating reduces other losses in the system. Multi-exposure holographic dispersion gratings enable the multiplexer/demultiplexer for extremely broad-band simultaneous transmission and reflection operation. Individual Bragg plane sets recorded in the grating are dedicated to and operate efficiently on discrete wavelength ranges.

1990-01-01

42

Fabrication and characterization of low aberration micrometer-sized electron lenses  

British Library Electronic Table of Contents (United Kingdom)

Intrinsic spherical aberrations of electron lenses have been the major resolution limiting factor in electron microscopes for several decades. While effective correctors have recently been implemented, an alternative to correct these aberrations is to circumvent them by scaling down lens dimensions by several orders of magnitude. We have fabricated electrostatic lenses exhibiting one micrometer diameter apertures and evaluated their beam forming properties against predictions from numerical ray tracing simulations. It turns out that it is routinely possible to shape a paraxial low-energy electron beam by such micron-sized lenses. Beam profiles have been measured both at a distant detector as well as in a plane close to the lens. It is shown that the lens can form a parallel beam extending ...

2010-01-01

43

The role of metallothionein IIa in defending lens epithelial cells against cadmium and TBHP induced oxidative stress  

UK PubMed Central (United Kingdom)

PurposeHeavy metals and other forms of oxidative stress have been implicated as key factors in the formation of age-related cataract in humans. Metallothioneins are...Full Text Available

44

Optical System Assessment for Design: Numerical Ray Tracing in the Gaussian Pupil,  

Science.gov (United States)

The continuing rapid increase in available computing power has not reduced the importance of efficient methods of optical system assessment for automatic lens design. On the contrary, the new capabilities simply show that truly automatic optical design wi...

1988-01-01

45

Obtaining a contact lens acquired electroretinogram in the presence of topical anesthetic hypersensitivity.  

Science.gov (United States)

Clinical circumstances often demand flexibility in electrodiagnostic procedures. We present a clinical case that required alteration of our routine full-field electroretinography technique. The patient presented with reports of allergy to Xylocaine (lidocaine) and refused the use of any type of topical anesthetic drops. This conflicted with our routine ERG method that combines the use of the Henkes Lovac hard contact lens and the topical anesthetic Alcaine (proparacaine hydrochloride). We acquired a successful electroretinogram without topical anesthesia by using a "piggy-back" system involving the interposition of a soft hydrophilic contact lens between the cornea and the recording hard lens. The procedure yielded excellent ERG recordings and was well tolerated. This non-routine technique was also compared to our standard ERG technique using a normal volunteer. It appears that this proposed "piggy-back" technique is a ...

2007-11-06

46

Localisation of glycoproteins and glycosaminoglycans during early eye development in the macaque.  

UK PubMed Central (United Kingdom)

The composition of the extracellular matrix (ECM) was examined in the developing lens and optic cup (stages 11-16) of the long-tailed monkey (Macaca fascicularis) using peroxidase immunocytochemistry....Full Text Available

1995-02-01

47

Generation and control of sound bullets with a nonlinear acoustic lens  

UK PubMed Central (United Kingdom)

Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available

2010-04-20

48

Fabrication and characterization of low aberration micrometer-sized electron lenses.  

Science.gov (United States)

Intrinsic spherical aberrations of electron lenses have been the major resolution limiting factor in electron microscopes for several decades. While effective correctors have recently been implemented, an alternative to correct these aberrations is to circumvent them by scaling down lens dimensions by several orders of magnitude. We have fabricated electrostatic lenses exhibiting one micrometer diameter apertures and evaluated their beam forming properties against predictions from numerical ray tracing simulations. It turns out that it is routinely possible to shape a paraxial low-energy electron beam by such micron-sized lenses. Beam profiles have been measured both at a distant detector as well as in a plane close to the lens. It is shown that the lens can form a parallel beam extending no more than 800 nm from the optical axes at a distance of 200 microm beyond the lens exit. We believe that these ...

2010-04-24

49

FEA Analysis of AP-0 Target Hall Collection Lens (Current Design)  

Energy Technology Data Exchange (ETDEWEB)

The AP-0 Target Hall Collection Lens is a pulsed device which focuses anti-protons just downstream of the Target. Since the angles at which the anti-protons depart the Target can be quite large, a very high focusing strength is required to maximize anti-proton capture into the downstream Debuncher Ring. The current design of the Collection Lens was designed to operate with a focusing gradient of 1,000 T/m. However, multiple failures of early devices resulted in lowering the normal operating gradient to about 750 T/m. At this gradient, the Lens design fares much better, lasting several million pulses, but ultimately still fails. A Finite Element Analysis (FEA) has been performed on this Collection Lens design to help determine the cause and/or nature of the failures. The Collection Lens magnetic field is created by passing high current through a central conductor cylinder. A uniform ...

2001-06-22

50

Changes in Rabbit and Cow Lens Shape and Volume upon Imposition of Anisotonic Conditions  

UK PubMed Central (United Kingdom)

In vivo, mammalian lenses have the capacity to effect fully reversible changes in shape, and possibly volume, during the accommodation process. Isolated lenses also change shape...Full Text Available

2009-10-01

51

Customized computer models of eyes with intraocular lenses  

Science.gov (United States)

We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle ?, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the eye with only the cornea, and these increased on average when the IOL geometry and position were included. Relevant individual aberrations were well predicted by the complete eye model. Corneal spherical aberration and horizontal coma were compensated by the IOL, and in 58.3% of the cases IOL tilt and decentration contributed to compensation of horizontal coma. We conclude that customized computer eye models are a good representation of real eyes with IOLs and allow understanding of the relative contribution of optical, geometrical and surgically-related factors to image quality. ...

2007-03-01

52

The Stefan Problem Revisited: A Continuum Model of Frost Heave  

Science.gov (United States)

The classical Stefan problem describes the motion of a solidification front through a uniform half-space in response to a step change in temperature on its boundary. The predictions of such a model can be applied quite accurately to the freezing of water in a porous medium so long as the pore geometry remains unaltered by the passing solidification front. It is observed, however, that in fine-grained porous media, ice has a tendency to form in segregated horizontal bands, known as ice lenses, that disrupt the regular pattern of heat flow through their enhanced consumption of latent heat. This process, known as frost heave, causes significant ground deformation in regions subject to prolonged freezing, and is one of the most important weathering processes in polar and alpine regions. Recent improvements to our understanding of the mechanics of ice lens nucleation and growth are applied here to predict the conditions and characteristics of frost heave in a ...

2005-12-01

53

The effects of a timolol maleate gel-forming solution on normotensive beagle dogs.  

Science.gov (United States)

The effects of a timolol maleate gel-forming solution (TMGS) on intraocular pressure (IOP), blood pressure (BP), and pupil size (PS) were evaluated in normotensive dogs. TMGS was administered once daily to six normotensive beagle dogs. TMGS administration reduced IOP and PS. The hypotensive effect persisted for 24 hr after the administration. The mean reduction in IOP was 5.3 mm Hg (P<0.01). The changes in BP and PS were not significant. These results suggest that TMGS can potentially be used in the treatments of glaucoma and ocular hypertension in dogs. PMID:16820724

2006-06-01

54

Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic ...

1997-05-27

55

3-Dimensional Mapping of Corneal Topography and Thickness  

CERN Document Server

Optical sections of the cornea are obtained by illumination with a collimated beam expanded in a fan shape by a small rotary cylindrical lens. The light diffused from the cornea is observed by two cameras and processed in order to yield the surfaces' profiles. The optical system used to project a thin rotating line on the cornea consists of a white light source provided with optical fiber bundle output which is first conditioned by a set of lenses so that it would produce a spot on the cornea. A small cylinder lens is used to expand the beam in one direction so that a thin line illuminates the cornea, rather than a spot. The cylinder lens is provided with motor driven rotation about an axis normal to its own in order to rotate the line on the cornea such that the projected line scans the whole cornea; the illuminator is completed with a slit aperture. The cornea is not perfectly transparent, scattering some of the light ...

2003-01-01

56

The impact of continuing professional development on ophthalmic dispensing of progressive addition lenses in the Asia-Pacific region  

British Library Electronic Table of Contents (United Kingdom)

Background:- Discrepancies exist in optometric education, practice and regulation across the Asia-Pacific region and the competence of optometric practitioners in adopting new lens technologies may vary widely. Over the past 10-years, a continuing professional development program, Varilux Academy Asia-Pacific (VAAP), was implemented and conducted in countries across the Asia-Pacific region to improve practitioners' understanding of optometric fitting principles, with special emphasis on progressive addition lenses (PAL). The aim was to demonstrate the effectiveness of VAAP and to compare the competence of practitioners across the Asia-Pacific region in new lens fitting technologies. Methods:- From 2002 to 2008, all VAAP participants from 12 countries across Asia-Pacific were invited to com...

2011-01-01

57

Small hemielliptic dielectric lens antenna analysis in 2-D: boundary integral equations versus geometrical and physical optics  

CERN Document Server

We assess the accuracy and relevance of the numerical algorithms based on the principles of Geometrical Optics (GO) and Physical Optics (PO) in the analysis of reduced-size homogeneous dielectric lenses prone to behave as open resonators. As a benchmark solution, we use the Muller boundary integral equations discretized with trigonometric Galerkin scheme that has guaranteed and fast convergence as well as controllable accuracy. The lens cross-section is chosen typical for practical applications, namely an extended hemiellipse whose eccentricity satisfies the GO focusing condition. The analysis concerns homogeneous lenses made of rexolite, fused quartz, and silicon with the size varying between 3 and 20 wavelengths in free space. We consider the 2-D case with both E- and H-polarized plane waves under normal and oblique incidence, and compare characteristics of the near fields.

2010-01-01

58

Radioexposure of children in cranial examinations with new-generation CT equipment  

Energy Technology Data Exchange (ETDEWEB)

Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.

1983-04-01

59

Microbial keratitis after corneal laser refractive surgery  

British Library Electronic Table of Contents (United Kingdom)

Corneal laser refractive surgery is increasingly being performed on patients with the aim of improving unaided vision. Most candidates for surgery have excellent spectacle- or contact lens-corrected vision. Although microbial keratitis following refractive surgery is a rare complication, and usually has a good visual outcome, it can be sight-threatening. The spectrum of pathogens differs to other causes of microbial keratitis, such as contact lens-associated keratitis, and a different management approach is required. Postoperatively, patients are prescribed topical steroids and broad-spectrum topical antibiotics, typically fluoroquinolones. These do not cover unusual organisms, such as fungi, Nocardia, Acanthamoeba and some atypical mycobacteria. In post-laser-assisted in situ keratomileus...

2011-01-01

60

Acoustic metamaterials for new two-dimensional sonic devices  

Energy Technology Data Exchange (ETDEWEB)

It has been shown that two-dimensional arrays of rigid or fluidlike cylinders in a fluid or a gas define, in the limit of large wavelengths, a class of acoustic metamaterials whose effective parameters (sound velocity and density) can be tailored up to a certain limit. This work goes a step further by considering arrays of solid cylinders in which the elastic properties of cylinders are taken into account. We have also treated mixtures of two different elastic cylinders. It is shown that both effects broaden the range of acoustic parameters available for designing metamaterials. For example, it is predicted that metamaterials with perfect matching of impedance with air are now possible by using aerogel and rigid cylinders equally distributed in a square lattice. As a potential application of the proposed metamaterial, we present a gradient index lens for airborne sound (i.e. a sonic Wood lens) whose functionality is demonstrated by multiple ...

2007-09-15

 
 
 
 
61

Detection of Visual Deficits in Aging DBA/2J Mice by Two Behavioral Assays  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The DBA/2J mice have been used as an animal model for human pigmentary glaucoma. However, these mice develop various degrees of disease symptoms at different ages, making it difficult to detect pathological changes of retinal degeneration at glaucoma onset. The purpose of this study is to develop a non-invasive assay to identify individual mice that develop visual deficits. Materials and Methods: We apply two behavioral tests, a swimming test of visual discrimination and a test of optomotor response, to identify glaucomatous DBA/2J mice. We then examine whether the elevation of intraocular pressure (IOP), the common risk factor for glaucoma, affects visual performances of the DBA/2J mice. We further compare the retinal ganglion cell death, one of the signature glaucoma symptoms, i...

2011-01-01

62

Solar Eclipse Images - SDAC Home Page - NASA  

Science.gov (United States)

Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...

63

Evaluation of PLZT goggles. Final report June 78-April 79  

Energy Technology Data Exchange (ETDEWEB)

Air Force Prototype Thermal Flash Protective Device (TFPD) Goggles were furnished to USAFSAM by the Life Support System Program Office, Aeronautical Systems Division, for determination and evaluation of their eye-type goggles caused stressed areas. The bonding used in the production model eliminated the stressed areas, resulting in increased closed-state optical density, particularly in the upper nasal area of the lens.

1980-12-01

64

Plane Shock Generator Explosive Lens: Shock characterization of 4340 and PH13-8Mo steels, C360 brass and PZT 65/35 ferro-electric ceramic  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories is currently involved in the optimization of a Plane Shock Generator Explosive Lens (PSGEL). The PSGEL component consists of a detonator, explosive, brass cone and tamper housing. The purpose of the PSGEL component is to transmit a plane shock wave through the 4340 steel bulkhead (wave separator) which has a ferro-electric (PZT)ceramic disk attached to the opposite surface of the steel bulkhead. The planar shock wave depolarizes the PZT 65/35 ferro-electric ceramic to produce an electrical output. One aspect of the optimization program involves the possible replacement of 4340 steel with PH13-8Mo steel for the bulkhead. These materials, as well as the PZT 65/35 ferro-electric ceramic and the brass for the cone, required the stock characterization with respect to Hugoniot parameters. The work presented here gives the shock Hugoniot values for these four materials and documents their measurements.

1994-03-01

65

Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis  

International Nuclear Information System (INIS)

The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including Fresnel lens and phase ...

2003-06-01

66

Tolerance analysis of a phase space beam analyzer  

Science.gov (United States)

The phase space beam analyzer is a measurement instrument that is applied in laser technology to perform analyses of the spatial and angular distribution of rays. We are interested in this instrument as a means to characterize non-coherent light sources. In this context, a closer look at the tolerances of this optical instrument was considered useful. Having a so-called quadrupole lens as a key element, the phase space beam analyzer is a device that features anamorphic optical properties. To describe these anamorphic properties, recurrence was made to a description by extended ray-transfer matrices. This formalism allows for an analysis of the alignment tolerances of the phase space beam analyzer and facilitates a study of the sensitivities of the instrument. The analysis is complemented using numerical ray tracing.

2007-09-01

67

Reconceptualizing the Native/Nonnative Speaker Dichotomy  

British Library Electronic Table of Contents (United Kingdom)

This study reconceptualizes the native/nonnative dichotomy and provides a powerful lens to examine linguistic identities. In a study of 25 linguistically diverse teacher candidates in Canada, the respondents' native and nonnative self-ascription and self-assessed level of proficiency was juxtaposed with the judgment of their instructors. This process revealed that the native/nonnative dichotomy falls short in capturing the multifaceted nature of individuals' diverse linguistic identities and tends to misrepresent them. Within the specific social context under investigation, 6 linguistic categories that better represented the true linguistic identity of participants were identified. This inquiry reconceptualizes the controversial native/nonnative dichotomy by suggesting that linguistic iden...

2011-01-01

68

Laser-assisted solar cell metallization processing. Quarterly report No. 6, March 1-June 30, 1985  

Energy Technology Data Exchange (ETDEWEB)

A new lens was installed in the laser; the laser power was lowered and solar cells were made at different power levels. The concentration of the silver neodecanoate solution was changed to reduce linewidth. A cell fabrication run was completed using low-resistivity float-zone silicon. Experiments were initiated to investigate the use of titanium organometallic film, which not only forms an AR coating with a 400/sup 0/C hard bake, but may also help in bypassing front-metal evaporation because of high-reactivity of Ti with silicon. Progress in these areas is discussed.

1985-07-25

69

Interplay between the ray and mode effects in electromagnetic behavior of small-size hemielliptic dielectric lenses  

CERN Document Server

Focusing and resonance properties of two-dimensional small-size hemielliptic lenses made of different materials are studied numerically in order to estimate the influence of internal reflections on the radiation characteristics of dielectric lens antennas. Accuracy of in-house made algorithms based on combination of geometrical and physical optics and FDTD in the analysis of optical and modal effects in the behavior of such lenses is tested by comparison with the exact solution obtained using the Muller boundary integral equations. The range of applicability for the approaches is discussed.

2010-01-01

70

Emotional and Sexual Infidelity Offline and in Cyberspace  

Science.gov (United States)

This study investigated how men and women perceive online and offline sexual and emotional infidelity. Undergraduates from a large university in Northern Ireland participated in the study. It was found that men, when forced to decide, were more upset by sexual infidelity and women by emotional infidelity. It was also found that men were more likely to believe that women have sex when in love and that women believe that men have sex even when they are not in love. It was not, however, found that either men or women believed that having cybersex implied the other was also in love or that being in love online implied they were having cybersex. These results are explained through a social-cognitive lens.

2008-10-01

71

A finite-dimensional fermionic TQFT  

CERN Document Server

A fermionic - based on Grassmann--Berezin calculus of anticommuting variables - topological quantum field theory (TQFT) is considered, mainly in three dimensions. It is defined for piecewise-linear manifolds and, for a given triangulation, deals only with a finite number of variables. Despite its simple nature, it can distiguish between lens spaces L(7,1) and L(7,2). And despite its origin from a kind of Reidemeister torsion, it does this without using nontrivial representations of the fundamental group. Also, symbolic calculations are presented giving strong evidence of existence of similar theory in four dimensions.

2011-01-01

72

Visual recovery after vitrectomy for macular hole using 25-gauge instruments  

British Library Electronic Table of Contents (United Kingdom)

Abstract. Purpose: To determine whether vitrectomy with 25-gauge instruments contributes to better postoperative visual recovery after macular hole (MH) surgery. Methods: The medical records for 46 consecutive eyes operated for MH by a single surgeon were retrospectively examined. Vitrectomy had been performed with a 25-gauge instrument in 23 eyes (25-G group) and with a 20-gauge instrument in 23 eyes (20-G group). Postoperative visual acuity (VA) in logMAR (logarithm of the minimum angle of resolution) units after 1 week and 1, 3, 6, 9 and 12 months, operating time, and volume of intraocular irrigating fluid were compared between the two groups. Results: Mean preoperative logMAR VA was 0.72 in the 25-G group and 0.68 in the 20-G group (p = 0.282, unpaired t-test). One week after surgery, ...

2008-01-01

73

Short-term tolerability of once-daily timolol hemihydrate 0.5%, timolol maleate in sorbate 0.5%, and generic timolol maleate gel-forming solution 0.5% in glaucoma and/or ocular hypertension: A prospective, randomized, double-masked, active-controlled, three-period crossover pilot study  

British Library Electronic Table of Contents (United Kingdom)

Objective: The aim of this study was to compare symptoms and anterior segment tolerability with short-term (3-day) administration of once-daily timolol hemihydrate 0.5%, timolol maleate in sorbate 0.5%, and generic timolol maleate gel-forming solution 0.5% in the treatment of glaucoma and/or ocular hypertension. Methods: In this prospective, randomized, double-masked, active-controlled, 3-period crossover pilot study, eligible patients had primary open-angle, pigmentdispersion, or exfoliation glaucoma, and/or ocular hypertension in >=1 eye; had a best corrected visual acuity of 1.0 or better in each eye, as measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity testing chart; were receiving 1 glaucoma medication; and had an untreated intraocular pressure (IOP) ...

2009-01-01

74

Pseudophakic and aphakic retinal detachment mimicking cystoid macular edema.  

Science.gov (United States)

Seventeen eyes of patients who were being followed by their ophthalmologists for aphakic (8 eyes) or pseudophakic (9 eyes) cystoid macular edema (CME) were examined on referral. All eyes showed retinal detachment (RD), and eight eyes had CME with RD. Most RDs were inferior and shallow. Proliferative vitreoretinopathy (PVR) was noted in 15 eyes (88.2%). There was history of vitreous loss during the last intraocular surgery in 88.2% eyes. Visual acuity ranged from 20/40 to hand movements. Fundus view was hazy in most eyes, and indirect ophthalmoscopy was most useful in detecting RD. Retinal reattachment with scleral buckling and/or vitrectomy was achieved in 16 eyes (94.1%). Postoperative visual recovery was jeopardized due to longstanding macular detachment of greater than 1 month in 11 eyes (64.7%). Eight eyes (47%) achieved 20/50 vision whereas 25% did not improve to better than 20/400. Factors leading to failure in making the correct diagnosis and their ...

1987-07-01

75

HSP70, the earliest-induced gene in the zebrafish retina during optic nerve regeneration: Its role in cell survival  

British Library Electronic Table of Contents (United Kingdom)

Fish retinal ganglion cells (RGCs) can survive and regrow their axons after optic nerve injury. Injured RGCs express anti-apoptotic proteins, such as Bcl-2, after nerve injury; however, upstream effectors of this anti-apoptotic protein are not yet fully understood. Heat shock proteins (HSPs) play a crucial role in cell survival against various stress conditions. In this study, we focused on HSP70 expression in the zebrafish retina after optic nerve injury. HSP70 mRNA and protein levels increased rapidly 2.3-fold in RGCs by 1-6 h after injury and returned to control levels by 1-3 days. HSP70 transcription is regulated by heat shock factor 1 (HSF1). HSF1 mRNA and phosphorylated-HSF1 protein rapidly increased by 2.2-fold in RGCs 0.5-6 h after injury. Intraocular injection of HSP inhibitor I s...

2011-01-01

76

Understanding collaborative filtering parameters for personalized recommendations in e-commerce  

British Library Electronic Table of Contents (United Kingdom)

Collaborative Filtering (CF) is a popular method for personalizing product recommendations for e-Commerce and customer relationship management (CRM). CF utilizes the explicit or implicit product evaluation ratings of customers to develop personalized recommendations. However, there has been no in-depth investigation of the parameters of CF in relation to the number of ratings on the part of an individual customer and the total number of ratings for an item. We empirically investigated the relationships between these two parameters and CF performance, using two publicly available data sets, EachMovie and MovieLens. We conducted three experiments. The first two investigated the relationship between a particular customer?s number of ratings and CF recommendation performance. The third experim...

2007-01-01

77

Spitzer Imaging of Herschel-ATLAS Gravitationally Lensed Submillimeter Sources  

CERN Document Server

We present physical properties of two submillimeter selected gravitationally lensed sources, identified in the Herschel Astrophysical Terahertz Large Area Survey. These submillimeter galaxies (SMGs) have flux densities > 100 mJy at 500 um, but are not visible in existing optical imaging. We fit light profiles to each component of the lensing systems in Spitzer IRAC 3.6 and 4.5 um data and successfully disentangle the foreground lens from the background source in each case, providing important constraints on the spectral energy distributions (SEDs) of the background SMG at rest-frame optical-near-infrared wavelengths. The SED fits show that these two SMGs have high dust obscuration with Av ~4 to 5 and star formation rates of ~100 M_sun/yr. They have low gas fractions and low dynamical masses compared to 850 um selected galaxies.

2010-01-01

78

Researching ethnic minority students in a Chinese context: mixed methods design for cross cultural understandings  

British Library Electronic Table of Contents (United Kingdom)

Research on and with ethnic minority students is characterised by a growing international literature that privileges 'liberal multiculturalism' as a lens through which to understand their experiences, yet ethnic diversity is constructed and responded to in many societies that are not underpinned by liberal democratic values. In this paper we use Joppke's binary to show how researching ethnic minority students outside of a liberal democratic framework requires methodologies that enable researchers to see beyond the invisibility that is often attached to ethnic minorities. We show how invisibility (i.e. antidiscrimination) can also be further culturally constructed, confounding even more any broader multicultural project. We canvass four broad areas including the role of legally binding legi...

2011-01-01

79

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

80

RF conditioned dc discharges for excitation of rare gas halide lasers. Final report  

Energy Technology Data Exchange (ETDEWEB)

Results of experiments performed utilizing high-power microwave sources for laser-discharge switching and preionization are reported. These results are not definitive, but are promising. Significant preionization using microwaves is possible. Some ability to switch the discharge and operate a laser have been demonstrated. More work needs to be performed to perfect the microwave coupling to the laser mixture. In particular, experiments with the microwaves better concentrated between the electrodes should be performed. The best way to accomplish this appears to be using the side-feed geometry; however, a large expansion of the microwaves should occur (to well below the power able to break down the window), and then a cylindrical lens should be used to focus the microwaves between the electrodes. 2 references.

1983-01-01

 
 
 
 
81

Plasma density ramp for relativistic self-focusing of an intense laser  

International Nuclear Information System (INIS)

It is known that a high-power laser propagating through an underdense plasma can acquire a minimum spot size due to relativistic self-focusing. Beyond the focus, the nonlinear refraction starts weakening, and the spot size of the laser increases, showing periodic self-focusing/ defocusing behavior with the distance of propagation. To overcome the defocusing, we propose the introduction of a localized upward plasma density ramp. In the presence of an upward ramp of plasma density, the laser beam obtains a minimum spot size and maintains it with only a mild ripple. For suitable parameters of the laser and the plasma, we have deduced conditions for the self-focusing. This kind of plasma density ramp may be observed in a gas-jet plasma experiment and resembles a plasma lens.

2007-05-01

82

PIV measurements of flows around the wind turbines with a flanged-diffuser shroud  

British Library Electronic Table of Contents (United Kingdom)

The wind turbines with a flanged-diffuser shroud-so called ?wind lens turbine??-are developed as one of high performance wind turbines by Ohya et al. In order to investigate the flow characteristics and flow acceleration, the paper presents the flow velocity measurements of a long-type and a compact-type wind turbines with a flanged-diffuser shroud by particle image velocimetry. In the case of the long type wind turbine, the velocity vectors of the inner flow field of the diffuser for turbine blades rotating and no blades rotating are presented at Reynolds number, 0.9?105. Furthermore the flow fields between with and without rotating are compared. Through the PIV measurement results, one can realize that the turbine blades rotating affects as suppress the disturbance and the flow separatio...

2008-01-01

83

Molecular prospecting for cryptic species in Phyllodistomum lacustri (Platyhelminthes, Gorgoderidae)  

British Library Electronic Table of Contents (United Kingdom)

Rosas-Valdez, R., Choudhury, A. & Prez-Ponce de Len, G. (2011). Molecular prospecting for cryptic species in Phyllodistomum lacustri (Platyhelminthes, Gorgoderidae). -Zoologica Scripta, 40, 296-305. Partial sequences of the 28S ribosomal RNA and cytochrome c oxidase I (COI) genes were compared among populations of a widely distributed and morphologically uniform digenean species in North America, Phyllodistomum lacustri, a parasite characteristically associated with ictalurid catfishes. Specimens were collected from the urinary bladder of ictalurid hosts in six localities of North America, spanning most of the latitudinal range of this freshwater fish group. Sequences of other congeneric species, including a potentially close relative, P.-staffordi, were also obtained and used for comparis...

2011-01-01

84

Micromachined electrostatic vertical actuator  

Energy Technology Data Exchange (ETDEWEB)

A micromachined vertical actuator utilizing a levitational force, such as in electrostatic comb drives, provides vertical actuation that is relatively linear in actuation for control, and can be readily combined with parallel plate capacitive position sensing for position control. The micromachined electrostatic vertical actuator provides accurate movement in the sub-micron to micron ranges which is desirable in the phase modulation instrument, such as optical phase shifting. For example, compact, inexpensive, and position controllable micromirrors utilizing an electrostatic vertical actuator can replace the large, expensive, and difficult-to-maintain piezoelectric actuators. A thirty pound piezoelectric actuator with corner cube reflectors, as utilized in a phase shifting diffraction interferometer can be replaced with a micromirror and a lens. For any very precise and small amplitudes of motion` micromachined electrostatic actuation may be used because it is the ...

1999-10-19

85

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

86

High-vacuum time-resolved laser-induced incandescence of?flame-generated soot  

British Library Electronic Table of Contents (United Kingdom)

We have measured time-resolved laser-induced incandescence of flame-generated soot under high-vacuum conditions (4.1?10?6 mbar) at an excitation wavelength of 532 nm with laser fluences spanning 0.06?0.5 J/cm2. We generated soot in an ethylene/air diffusion flame, introduced it into the vacuum system with an aerodynamic lens, heated it using a pulsed laser with a spatially homogeneous and temporally smooth laser profile, and recorded LII temporal profiles at 685 nm. At low laser fluences LII signal decay rates are slow, and LII signals persist beyond the residence time of the soot particles in the detection region. At these fluences, the temporal maximum of the LII signal increases nearly linearly with increasing laser fluence until reaching a plateau at ?0.18?J/cm2. At higher fluences, th...

2011-01-01

87

Flame propagation characteristics and flame structures of zirconium particle cloud in a small-scale chamber  

British Library Electronic Table of Contents (United Kingdom)

Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...

2010-01-01

88

Design creativity: static or dynamic capability?  

British Library Electronic Table of Contents (United Kingdom)

Purpose - Viewing creativity through the theoretical lens of the resource-based view, the paper attempts to answer a fundamental question: is design creativity a static or dynamic capability? If static, then firms need to acquire personnel who are already creative. If dynamic, then personnel's creative talents should be developed through training. Design/methodology/approach - In an exploratory controlled experiment of 74 design engineers from ten firms, two forms of training emphasizing design creativity as static or dynamic capability were applied. Creative designs developed by the participants were judged by professionals inside each organization. Results were analyzed using structural equation modeling. Findings - The exploratory findings support the notion that design creativity is a ...

2008-01-01

89

Contact lens disinfection by ultraviolet light  

Energy Technology Data Exchange (ETDEWEB)

A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction.

1989-12-15

90

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

91

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where ...

2010-02-05

92

Morphological survey of bar, lens, and ring components in galaxies: Secular evolution in galaxy structure  

International Nuclear Information System (INIS)

A morphological survey of barred galaxies is made to investigate the frequency of occurrence, nature, and size distributions of bars, lenses, inner and outer rings, and global spiral structure. The 121 brightest available barred galaxies are examined on Sky Survey copy plates, and on deeper and larger-scale plates, with the following main results.1. Lenses and inner rings are components of major importance in barred galaxies, occurring, respectively, in 54% of SBO--SBa, and 76% of SBab--SBc galaxies. Few early-type galaxies have rings; almost no late-type ones have lenses.2. There is an intimate connection between bars and lenses: in 17 of 20 galaxies with both components, the bar exactly fills the lens in one dimension.3. We suggest that lenses originate as bars, through an unknown process which makes some bars evolve away to a nearly axisymmetric state. Several properties of the proposed process are deduced. We emphasize the possible importance of internal ...

93

Efficacy and tolerability of 0.5% timolol maleate ophthalmic gel-forming solution QD compared with 0.5% levobunolol hydrochloride BID in patients with open-angle glaucoma or ocular hypertension.  

Science.gov (United States)

We compared the efficacy of timolol maleate ophthalmic gel-forming solution 0.5% QD with that of levobunolol hydrochloride 0.5% BID, as measured by change in intraocular pressure (IOP), effect on heart rate, and ocular tolerability. The study had a positive-controlled, double-masked, randomized, multicenter, 12-week, two-period (6 weeks each), crossover design. One hundred fifty-two patients with open-angle glaucoma or ocular hypertension were randomized to receive either timolol maleate gel-forming solution QD or levobunolol BID for 6 weeks, followed by a crossover to the alternate treatment. IOP and heart rate were measured at morning trough and peak during weeks 3, 6, 9, and 12. Timolol maleate gel-forming solution QD was comparable to levobunolol BID in reducing IOP at peak and trough. Although the effects on peak heart rate were similar between the two medications, the effect on trough heart rate of timolol maleate gel-forming solution QD was significantly ...

94

Visible-light resin-curing units: retinal hazards and protective lenses. Final report, December 1982-May 1986  

Energy Technology Data Exchange (ETDEWEB)

The potential retinal hazard of dental visible-light photopolymerization units and the efficacy of protective lenses for reducing the potential hazards were assessed. The spectral radiance profiles of 11 visible-light photopolymerization units were measured; and the results were then weighted according to the American Conference of Governmental Industrial Hygienists (ACGIH) Blue Light and Thermal Hazard Functions. The results indicate that there are no thermal hazards to the retina even for the worst case condition. None of the blue-light hazard maximum permissible exposure times is short enough to be of concern unless the individual operator chooses to focus on the light source for an extended period. Those individuals who elect to stare at the light during curing procedures should consider the purchase of protective lenses. The special transmission profiles of 16 protective lenses were measured and new permissible exposure limits calculated for each lens/unit ...

1986-11-01

95

The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)  

CERN Document Server

The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was released at the IAU General Assembly on 2009 August 10. It is the first all-sky release in this series and contains just over 100 million objects, about 95 million of them with proper motions, covering about R = 8 to 16 magnitudes. Current epoch positions are obtained from the observations with the 20 cm aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates from the SPM program (YSJ1) form the basis for proper motions. These data are supplemented by all-sky Schmidt plate survey astrometry and photometry obtained from the SuperCOSMOS project, as well as 2MASS near-IR ...

2010-01-01

96

Radial keratoneuritis as a presenting sign in acanthamoeba keratitis.  

Science.gov (United States)

The visual outcomes of Acanthamoeba keratitis, a rare cause of corneal infection, can be devastating. This paper reports two contact lens wearers with severe pain and photophobia who presented to the emergency room. Biomicroscopy revealed radial keratoneuritis in both individuals. Tissue culture on a nonnutrient agar plate with Escherichia coli overlay resulted in a heavy growth of Acanthamoeba. The inpatient treatment included 0.02% polyhexamethylene biguanide, chlorhexidine, neomycin/polymyxin B/bacitracin (Neosporin), and oral fluconazole, which successfully controlled the corneal infection and improvement in the best corrected visual acuity in both patients. Infection did not recur during the 12-month follow-up period. Acanthamoeba keratitis can present as radial keratoneuritis, mimicking other common corneal infections resulting in diagnostic and treatment delays. Early diagnosis and prudent treatment of Acanthamoeba keratitis are the keys to restoring vision ...

2011-07-01

97

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained from these data. A superheterodyne receiver at 60--90 GHz has been built which views ...

0854-01-01

98

Microlens Parallax Measurements with a Warm Spitzer  

CERN Document Server

Because Spitzer is an Earth-trailing orbit, losing about 0.1 AU/yr, it is excellently located to perform microlens parallax observations toward the Magellanic Clouds (LMC/SMC) and the Galactic bulge. These yield the so-called ``projected velocity'' of the lens, which can distinguish statistically among different populations. A few such measurements toward the LMC/SMC would reveal the nature of the lenses being detected in this direction (dark halo objects, or ordinary LMC/SMC stars). Cool Spitzer has already made one such measurement of a (rare) bright red-clump source, but warm (presumably less oversubscribed) Spitzer could devote the extra time required to obtain microlens parallaxes for the more common, but fainter, turnoff sources. Warm Spitzer could observe bulge microlenses for 38 days per year, which would permit up to 24 microlens parallaxes per year. This would yield interesting information on the disk mass function, particularly old brown dwarfs, which at ...

2007-01-01

99

Methodology for assessing performance of waste management systems  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the methodology provided in this report is to select the optimal way to manage particular sets of waste streams from generation to disposal in a safe and cost-effective manner. The methodology described is designed to review the entire waste management system, assess its performance, ensure that the performance objectives are met, compare different LLW management alternatives, and select the optimal alternative. The methodology is based on decision analysis approach, in which costs and risk are considered for various LLW management alternatives, a comparison of costs, risks, and benefits is made, and an optimal system is selected which minimizes costs and risks and maximizes benefits. A ''zoom-lens'' approach is suggested, i.e., one begins by looking at gross features and gradually proceeds to more and more detail. Performance assessment requires certain information about the characteristics of the waste streams ...

1988-01-01

100

Focused ion-beam line profiles: A study of some factors affecting beam broadening  

Energy Technology Data Exchange (ETDEWEB)

The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ``wings`` that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least for the lighter ions ...

1995-11-01

 
 
 
 
101

Focused ion-beam line profiles: A study of some factors affecting beam broadening  

International Nuclear Information System (INIS)

The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ''wings'' that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least for the lighter ions ...

102

Dependence of proton beam polarization on ion source transition configurations  

Energy Technology Data Exchange (ETDEWEB)

The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in the so-called ``polarized states`` were equal and opposite. It was observed that the hexapole lens of the ion source produced beam polarization in the absence of any transition. The beam polarization as a ...

1997-11-11

103

Cyclin-Dependent Kinase Inhibitor p16 and p21 Expression, and Cell Cycle Change in Human Lens Epithelial Cell Line SRA 01/04 following Contact Inhibition in Normal Culture  

British Library Electronic Table of Contents (United Kingdom)

Abstract Purpose: To describe the pattern of expression of the cyclin-dependent kinase inhibitors (CDKIs) p16, p21 and p27, and the cell cycle in SRA 01/04 cells relative to contact inhibition. Methods: SRA 01/04 cells were grown to overconfluence under normal conditions. At various phases of the cell growth, cells were assayed by flow cytometry and Western blotting for the expression of CDKIs. Results: Expression of p16 was detected from early logarithmic growth to stationary phases, during which the number of cells in G0/G1 increased from 46 to 69%. Expression of p21 was detected only during the overgrowth phase, when 60% of the cells were in G0/G1. Expression of p27 was not observed in SRA 01/04 cells. Conclusions: p16 expression was likely mediated by G0/G1 arrest to induce contact inh...

2011-01-01

104

0--30 keV low-energy focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

1988-05-01

105

0--30 keV low-energy focused ion beam system  

International Nuclear Information System (INIS)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

106

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator of similar structure as the JT-60U ion source, at Negative Ion Acceleration Test Stand (NIAS). High energy negative ion beams of the same perveance as that of 500 keV full power operation of ...

2000-03-01

107

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV image (512x512x8 bit) ...

1990-12-20

108

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV image (512x512x8 bit) ...

1990-12-01

109

Photographic surface photometry of NGC 2855 and NGC 6771 galaxies  

International Nuclear Information System (INIS)

Photographic surface photometry in the BV system was carried out two Southern SO's galaxies, NGC 2855 and NGC 6771. B and V isophote maps were obtained as well as geometric and integrated parameters as position angles, inclination, diameters, magnitudes and integrated colors. Each luminosity profile was decomposed into bulge and disk contributions, each component being fitted to convenient laws. For NGC 2855 de Vaucouleurs law described well the bulge whereas the disk showed an exponential distribution. For NGC 6771 the barred nuclear bulge as well as the disk was best fitted by exponential laws. Additional luminosity components due to an inner fragmented ring were identified in NGC 2855 and due to both a quite prominent lens and well defined ring in NGC 6771. In this galaxy the minor axis, oriented almost edge-on, present clues of another luminosity component besides the bulge and the thin disk. For both galaxies the disk central surface brightness was found to be ...

2009-05-10

110

On the properties of plasma crystals  

Energy Technology Data Exchange (ETDEWEB)

When a plasma becomes contaminated by foreign particles, generically referred to as dust, the result is called a dusty plasma. At the present time there is a great deal of interest in dusty plasmas because of their roles in terrestrial and extra-terrestrial processes - semiconductor processing, high temperature fusion experiments, stellar formation and the rings of Saturn. This thesis is concerned with the role of dust in processing type plasmas. In the following experiments, artificial dust is introduced into a parallel electrode plasma chamber. Ions and electrons in the plasma charge the dust particles and they become suspended in the plasma due to the balancing of electric and gravitational forces. By illuminating the suspended dust with laser light and using an extremely high speed camera fitted with a macro lens to look at the scattered light, the dust particles are observed directly. Specially written computer software is then able to track and analyse the ...

1999-07-01

111

Evaluation of Ordos Basin in China  

Energy Technology Data Exchange (ETDEWEB)

Ordos basin lies in the north-central China, in a compression tectonic regime, with an area of approximately 250,000 km{sup 2}, including several pay zones ranging from Cambrian to Jurassic. It is one of the earliest-formed marine to continental-superimposed basin in China, characterized by Proterozoic basin-marginal rifling and Lower-Paleozoic carbonate platform development followed by western thrusting and foreland depression during Mesozoic. It underwent several tectonic movements and is covered by several structural layers, with many play types developed, primarily thrust and anticlinal plays in the west, and differential compaction (river-channel sand lens) or drape as well as buried hill plays in the basin center and east. Ordos basin is a prolific gas basin with an estimated resource potential of gas 656,091 billion m{sup 3} in the Paleozoic strata and oil 2.0474 billion tons in the Mesozoic strata. In 1986, in the western part of the basin, the well Tian-1 ...

1996-06-01

112

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by a factor of 10 after ...

1990-11-01

113

A Research Perspective on Stakeholder Involvement in Radioactive Waste Management - State of the Art and Future Prospects  

Energy Technology Data Exchange (ETDEWEB)

Our modern society is increasingly faced with challenges and problems that cannot be solved by a purely technical, political or social approach. Radioactive waste disposal site selection and management can be characterised as one of these challenges that require a transdisciplinary approach, integrating social, philosophical and ethical aspects in a 'technical' practice. Along the spirit of this transdisciplinary approach, and in order to ensure the necessary public support for a policy decision regarding this practice, stakeholder involvement is more and more seen as a necessary policy element in the decision making process. The aim is to achieve the broad involvement of individuals from civil society, with significant representation from local communities, elected representatives and NGO's, as well as scientists from outside radioactive waste management organisations, together with established players in the field, such as the implementers of radioactive ...

2006-09-15

114

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam lines, each focused by six magnets. A 3-D ...

2002-07-01