Successful interface engineering requires compositional and electronic material characterization as a prerequisite for understanding and intentionally generating interfaces in photovoltaic devices. The paper gives an overview with several examples, all referring to Cu(In,Ga)(S,Se){sub 2} ('CIGSSe')-based solar cells, with an emphasis on characterization using highly specialized methods, such as elastic recoil detection analysis, X-ray emission spectroscopy and photoelectron spectroscopy using synchrotron and ultraviolet light for excitation, inverse photoemission spectroscopy and Kelvin probe force microscopy. First, the determination of the depth profile of the band gap energy E{sub g} in the absorber layer is demonstrated. The modification of E{sub g} towards both interfaces is discussed in terms of beneficial electronic effects. Next, the interface between absorber and buffer layers ...
Tetracycline is an antibiotic that absorbsultraviolet light at 355 nm and preferentially binds to atherosclerotic plaque both in vitro and in vivo. Tetracycline-treated human cadaveric aorta was compared with untreated aorta using several techniques: absorptive spectrophotometry; and tissue uptake of radiolabeled tetracycline, which showed 4-fold greater uptake by atheroma than by normal vessel. In addition, intravenous tetracycline administered to patients undergoing vascular surgery demonstrated characteristic fluorescence in surgically excised diseased arteries. Because of tetracycline's unique properties, the authors exposed tetracycline-treated and untreated aorta to ultraviolet laser radiation at a wavelength of 355 nm. They found enhanced ablation of tetracycline-treated atheroma compared with untreated atheroma. The plaque ablation caused by ultraviolet laser radiation was twice as ...
A rapid and accurate method for the direct simultaneous determination of nitrate and nitrite is proposed. The method is applied to the determination of nitrate and nitrite in rainwater and wastewater without preliminary separation. The determinations are performed by a CPA matrix method with ultraviolet spectrophotometric detection. The results obtained are in agreement with those obtained by conventional methods for the determination of nitrate and nitrite.
Experiments on Xanthium leaf discs were carried out to determine whether concomitant photoreactivation could be detected and if so, to compare its effects with photoreactivation due...Full Text Available
Thin films (1-10 ?m thickness) of nanocomposites (NC) based on organic coordinated compound (OCC) Eu(TTA)2(Ph3PO)2NO3 (where TTA is thenoyl trifluoroacetonate (C8H5F3O2S), Ph3PO - triphenylphosphine (C6H5PO) and polymer-polyvinylpyrrolidone ((C6H9NO)n) (PVP)) were obtained by chemical methods and with different molar ratios into organic polymer matrix. NC have been characterized by measurements of optical transmission, excitation spectra of photoluminescence (PL) and photoluminescence of NC at different concentrations of Eu(TTA)2(Ph3PO)2NO3 in NC. In the optical transmission of NC, the characteristic parameters of NC such as threshold absorbance, dependence on the concentration of the organic coordinated compound in NC, etc., have been determined The displacement of threshold absorption to infrared is observed with increasing of the concentration of the coordination material in NC. The excitation spectrum of photoluminescence of NC led the range from 200 to 400 nm ...
Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...
Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for different times.
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international activities, especially the EU ...
Lyman-limit absorption systems can play many important roles during and after cosmological reionization. Unfortunately, due to the prohibitively large dynamic range required, it is impossible to self-consistently include these systems in cosmological simulations. Using fast and versatile semi-numeric simulations, we systematically explore the spatial distribution of absorption systems during and following reionization. We self-calibrate the resulting number of absorbers to the mean free path (mfp) of the ionizing ultraviolet background (UVB), and present results at a given mfp and neutral hydrogen fraction. We use a simple optical depth criterion to identify the locations of absorbers. Our approach is fairly robust to uncertainties such as missing subgrid structure. Unlike at lower redshifts where the UVB is relatively uniform, at higher redshifts the fluctuations in the UVB and the HII morphology of reionization can drive ...
Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.
The non-invasiveness of autofluorescence technology may reduce sampling error and time delay for histopathology diagnosis. We establish biophotonic methods and guidelines to visualize and interpret early epithelial tissue changes that signify disease. Flexible and rigid fiber endomicroscopy instrumentation design parameters feasible for translation towards clinical use are in development.
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal ...
We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 months we disprove ...
uv irradiation (365 nm) of air-saturated methanol solutions of 20 drugs absorbing in the 300 to 400 nm region gave rise to oxygen uptake, as determined with a polarographic oxygen electrode. The drugs were tested for photosensitizing capability by either a Type I (free radical) or a Type II (single molecular oxygen) mechanism. This testing was done by the inclusion of either acrylamide or 2,5-dimethylfuran in the irradiated drug solution, with observation of the subsequent polymerization or oxidation, respectively. Phenothiazine and thiazide derivatives appear capable of photosensitization by both mechanisms; promethazine, trifluoperazine, and furosemide show relatively high reactivity. Diazepam (weak), hexachlorophene, aminacrine, pyrilamine, tetracycline, demeclocyline, quinine, and anthracene (strong) react only by a Type II mechanism, with a photosensitizing efficiency increasing in the order given. A correlation appears to exist with reports of in vivo ...
An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.
We present ultraviolet spectra of Mira's companion star from the Space Telescope Imaging Spectrograph (STIS) instrument on board the Hubble Space Telescope (HST). The companion is generally assumed to be a white dwarf surrounded by an accretion disk fed by Mira's wind, which dominates the UV emission from the system. The STIS UV spectrum is dominated by numerous, narrow H2 lines fluoresced by H I Ly-alpha, which were not detected in any of the numerous observations of Mira B by the International Ultraviolet Explorer (IUE). The high temperature lines detected by IUE (e.g., C IV 1550) still exist in the STIS spectrum but with dramatically lower fluxes. The continuum fluxes in the STIS spectra are also much lower, being more than an order of magnitude lower than ever observed by IUE, and also an order of magnitude lower than fluxes observed in more recent HST Faint Object Camera objective prism spectra ...
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed.
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed. (orig.).
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was ...
The meiotic spindle in the oocyte is composed of microtubules and plays an important role during chromosome alignment and separation at meiosis. Polarized light microscopy (PLM) could be useful for a non-invasive evaluation of the meiotic spindle and may allow removal of nuclear structures without fluorochrome staining and ultraviolet exposure. In this study, PLM was used to assess its potential application in porcine reproductive technologies. The objectives of the present study were to assess the efficiency of PLM to detect microtubule-polymerized protein in in vitro-matured porcine oocytes; to examine its effects on the oocyte developmental competence; to select oocytes based on the presence of the meiotic spindle detected by PLM; and to assess the efficiency oocyte enucleation assisted...
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. ...
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.
We report on characterization of a set of AlGaN/GaN multiple-quantum-well (MQW) photodetectors. The model structure used in the calculation is the p-i-n heterojunction with 20 AlGaN/GaN MQW structures in i-region. The MQW structures have 2nm GaN quantum well width and 15nm AlxGa1-xN barrier width. The cutoff wavelength of the MQW photodetectors can be tuned by adjusting the well width and barrier height. Including the polarization field effects, on increasing Al mole fraction, the transition energy decreases, the total noise increases, and the responsivity has a red shift, and so the detectivity decreases and has a red shift.
Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and ...
The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)
This paper described experiments on the adsorption of radon gas on surfaces of various materials. The experiments were carried out on three kinds of materials: Poly(vinyl chloride), polyethylene and stainless steel. On stainless steel, adsorption was not detectable. On the other hand, there was clearly adsorption on poly(vinyl chloride) and polyethylene. A poly(vinyl chloride) sheet of one square meter surface in a 5.3 L container absorbed approximately 20% of the radon. Radon adsorption has to be taken into account when radon concentration measurements in the air. (author)
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of complicating factors ...
A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.
Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbancedetected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw ...
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It means that the air and the helium do not ...
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an interrogation tool to provide ...
In this study, the effects of 325nm wavelength ultraviolet light irradiation on pitting corrosion behavior of type 340 stainless steel in a neutral chloride solution are studied. Further, the change of passive film with the light irradiation is analyzed using x-ray photoelectron spectroscopy. The mains results obtained therefrom are stated below. Pitting potential can be shifted in noble direction by the ultraviolet light irradiation. The effect of ultraviolet light irradiation is ore prominent in the pitting corrosion process than that in the passive film formation. The result of the analysis in terms of the birth and death stochastic probability process shows that pitting corrosion rate is decreased remarkably by the ultraviolet light irradiation at the formation of passive film, while the repassivation is slightly expedited by the ultraviolet light irradiation. On the other hand, ...
Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available
Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and ...
GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.
GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.
The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have recently demonstrated ...
We used the recuperation effect (see also 'Recuperation of infrared stimulated luminescence of feldspars' in this issue) for investigating the connection between infrared- and greenlight-stimulated luminescence (IRSL and GLSL) of feldspars by performing a 'double-bleach recuperation' experiment. A diode system was used for infrared (IR) stimulation, and a filtered-light unit for greenlight (GL) stimulation. Powdered feldspar samples (2 mg each) of known chemical characterisation from a mineral collection were used. After beta-irradiation with 180 Gy and storage in the dark for several weeks feldspar aliquots were bleached down to a residual level of {approx}1% of the initial level, first with IR and subsequently with GL. For both stimulations, detection of the stimulated luminescence was carried out in the near ultraviolet region (around 260-360 nm, peaked at 340 nm). Other aliquots were bleached in reverse ...
We used the recuperation effect (see also 'Recuperation of infrared stimulated luminescence of feldspars' in this issue) for investigating the connection between infrared- and greenlight-stimulated luminescence (IRSL and GLSL) of feldspars by performing a 'double-bleach recuperation' experiment. A diode system was used for infrared (IR) stimulation, and a filtered-light unit for greenlight (GL) stimulation. Powdered feldspar samples (2 mg each) of known chemical characterisation from a mineral collection were used. After beta-irradiation with 180 Gy and storage in the dark for several weeks feldspar aliquots were bleached down to a residual level of #approx#1% of the initial level, first with IR and subsequently with GL. For both stimulations, detection of the stimulated luminescence was carried out in the near ultraviolet region (around 260-360 nm, peaked at 340 nm). Other aliquots were bleached in reverse order (1st GL, 2nd IR). These ...
Cancer is a severe threat to human health. Early detection is considered the best way to increase the chance for survival. While the traditional cancer detection method, biopsy, is invasive, noninvasive optical diagnostic techniques are revolutionizing the way that cancer is diagnosed. Reflectance spectroscopy is one of these optical spectroscopy techniques showing promise as a diagnostic tool for pre-cancer detection. When a neoplasia occurs in tissue, morphologic and biochemical changes happen in the tissue, which in turn results in the change of optical properties and reflectance spectroscopy. Therefore, a pre-cancer can be detected by extracting optical properties from reflectance spectroscopy. This dissertation described the construction of a fiberoptic based reflectance system and the development of a series of modeling studies. This research is aimed at establishing an improved understanding of ...
Summary The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of ...
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained ...
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained ...
Metagenomics projects based on shotgun sequencing of populations of micro-organisms yield insight into protein families. We used sequence similarity clustering to explore proteins with a comprehensive dataset consisting of sequences from available databases together with 6.12 million proteins predicted from an assembly of 7.7 million Global Ocean Sampling (GOS) sequences. The GOS dataset covers nearly all known prokaryotic protein families. A total of 3,995 medium- and large-sized clusters consisting of only GOS sequences are identified, out of which 1,700 have no detectable homology to known families. The GOS-only clusters contain a higher than expected proportion of sequences of viral origin, thus reflecting a poor sampling of viral diversity until now. Protein domain distributions in the GOS dataset and current protein databases show distinct biases. Several protein domains that were previously categorized as kingdom specific are shown to have GOS examples in ...
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, equivalently, the soft X-ray emission) plays a fundamental role in the ...
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant ...
Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the air quality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters such as the concentration of Fluoral-P in ...
... The addition of 0.5 pphr of fine thermal carbon black to the polymers gave good resistance to 500 hours of ultraviolet (UV) xposure in a Weather ...
instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...
The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR steam generator with large capacity energy absorbing supports under the sponsorship of Ministry of Economical Trade and Industry. If energy absorbing supports are adopted for NPP heavy components, support structure of facility will be much simplified due to their seismic energy absorbing effect. The paper describes the results of lead damper element test and seismic test at Tadotsu Laboratory, using 1/2.5 scale PWR Steam Generator model supported by Lead Extraction Damper (LED) and development of characteristics evaluation formula of energy absorbing support. (author)
This paper deals with the electronic structure of ruthenium. Synchrotron radiation in the range from 15 to 45 eV and angle-resolved ultraviolet photoemission are used to map the energies of the electronic states. The Fermi surface of Ru is determined using angle-resolved ultraviolet photoemission spectroscopy. The experimental results are compared with calculated photoemission spectra obtained within the framework of the one-step model of photoemission. (author)
Spontaneous and ultraviolet-induced changeabilities of wine yeasts from the killer state to sensitive one have been studied. Observed often spontaneous changes of killer and neutral phenotypes under laboratory store conditions as well as high mutation frequency of genetic elements responsible for the killer indication on ultraviolet irradiation testify that often encounterability in nature and in the production of sensitive yeasts is attributed to high frequency of mutation changes of the killer and neutral phenotypes to the sensitive state.
The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.
The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of the growth of neural stem cells (PHPEMS groups was the same as that in control group (P>0.05). It was suggested that 0.1 Hz, 5 pulses stimulation of HPEMS within ...
The mechanism of trypsin inactivation by intact Hymenolepis diminuta has been investigated by biochemical and autoradiographic methods. Although worms inactivate trypsin and chymotrypsin in vitro, no inactivation of other endoproteases (subtilisin, pepsin and papain) could be demonstrated. Trypsin inactivation, as demonstrated by macromolecular substrates (azoalbumin, hemoglobin and casein), could not be detected using low molecular weight synthetic substrates such as N-p-benzoyl-DL-arginine-p-nitroanilide (BAPA) or N-p-tosyl-L-arginine methyl ester (TAME). In addition, the kinetic parameters (K/sub m/ and k_3) for H. diminuta-inactivated trypsin, using BAPA as the substrate, were not different from those of the native enzyme. The number of active sites for both native and inactivated trypsin were determined by titration with p-nitro-phenyl-p'-guanidinobenzoate. Absorbance values for both titrations were found to be identical. Dialysis, heating ...
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...
The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of two-dimensional ...
In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation enables reliable ...
The thin windows for the Muon Ionization Cooling Experiment (MICE) liquid Absorber will be fabricated from 6061-T6-aluminum. The absorber and vacuum vessel thin windows are 300-mm in diameter and are 180 mm thick at the center. The windows are designed for an internal burst pressure of 0.68 MPa (100 psig) when warm. The MICE experiment design calls for changeable windows on the absorber, so a bolted window design was adopted. Welded windows offer some potential advantages over bolted windows when they are on the absorber itself. This report describes the bolted window and its seal. This report also describes an alternate window that is welded directly to the absorber body. The welded window design presented permits the weld to be ground off and re-welded. This report presents a thermal FEA analysis of the window seal-weld, while the window is being welded. Finally, the results of a ...
Full text: Pigments possessing the ability to confer high solar reflectance have received considerable attention in recent years. The inorganic class of NIR reflective pigments are mainly metal oxides and are primarily employed in two applications: (i) visual camouflage and (ii) reducing heat build up. More than half of the solar radiation consists of near-infrared radiation (52%), the remaining being 43% visible light and 5% ultraviolet radiation. Over heating due to solar radiation negatively affects comfort in the built environment and contributes substantially to electrical consumption for air conditioning and release of green house gases. A pigment which has strong reflections in the NIR region (780-2500 nm) can be referred to as a 'cool' pigment. However, most of the NIR reflective inorganic pigments particularly yellow (eg. cadmium yellow, lead chromate, chrome titanate yellow etc.) contain toxic metals and hence their consumption is being limited. Replacing ...
A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction.
Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.
... energy absorption characteristics of composite sandwich panels, thermoplastic energy-absorbing subfloor structures, and shoulder belt pre- tensioners. ...
Random motion of a particle, emitting and absorbing tachyons, is investigated. It is shown that if bradyon is in equilibrium with neutral gas, i.e. it absorbs and emits tachyons, which do not have any charges, tha particle with each absorption-emittance of a tachyon changes its energy and momentum, never varying its own mass, and as a result it moves like a brownian particle. Thus, bradyon, interacting with tachyon gas, increases its momentum continuously in agreement with the Einstein-Fokker-Planck type equation.
The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO{sub 3} + 1 M NaNO{sub 3} + 2 {times} 10{sup {minus}5} M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO{sub 3} + x {times} 10{sup {minus}4} M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10{sup 3} could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN ...
The technology for flue gas desulfurization (FGD) with seawater is widely adopted by coal-fired power plants in coastal areas. SO2 in the flue gas is absorbed by alkaline seawater and transfered in aqueous phase as sulfite (SO3(2-)), and most SO3(2-) is transformed to sulfate (SO4(2-)) after an aeration process. The remaining SO3(2-) in the seawater discharged to sea area may be harmful to marine organism because of its biological toxicity, thus it is necessary to determine the concentration of SO3(2-) in the seawater for desulfurization. In this study, the method of determination of SO3(2-) in the seawater by ion chromatography was investigated. The separation was achieved on an IonPac AS14A column with 14 mmol/L NaOH-12 mmol/L Na2 CO3 solution as the mobile phase at a flow rate of 1.2 mL/min, and the detection was performed by a pulsed amperometric detector. Formaldehyde was added as a protective agent when sampling because the SO3(2-) is ...
For location of leakage at district heating pipelines several techniques are available today. If there is no wire bound lead monitoring system installed, the DH company has to apply mobile methods for detection and location and if possible characterization of leakage. Most mobile methods available today are restricted in application and often they cause supply disconnections, especially the location of very small leaks is difficult. The Institute for Environmental, Safety and Energy Technology (UMSICHT) has tested a new developed method that can be executed by own employees of DH companies that can be realised parallel to normal supply mode, and that is able to locate and characterize even very small leakages. (orig.) [Deutsch] Zur Lecksuche an Fernwaermeleitungen stehen verschiedene Techniken zur Verfuegung. Wurde beim Bau der Fernwaermetrasse kein drahtgebundenes Ueberwachungssystem eingebaut, ist der Netzbetreiber auf mobile Lecksuchmethoden angewiesen. Die ...
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken out of service for periodic tests or maintenance without interrupting the overall system performance. A control room color ...
I report on some recent work done in collaboration with E. de Rafael on the connection between ultraviolet renormalons in QCD and Nambu-Jona-Lasinio-like Lagrangians as its effective description at low energies. (orig.)
Oct 2, 2007 ... The Payload combines some of the most sensitive particle sensors .... provide state-of-the-art measurements of incoming x-ray, ultraviolet, .... It will be launched into a low-Earth orbit on a Delta 7320 rocket in September 2004. ...
Sunbed use is associated with increased risk of melanoma. Younger people might be more susceptible to the carcinogenic effects of ultraviolet radiation. We investigated the association between...Full Text Available
The ultraviolet photoelectron spectra of benzoic acid and 20 of its derivatives are presented. The low-energy regions of these spectra are deconvoluted and assigned using chemical substitution effects. 5 figures, 3 tables.
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...
BackgroundChildhood is a high risk time for ultraviolet induced skin damage as this age group has more time and opportunity to be outdoors in the sun. Children in Africa with the...Full Text Available
Ultraviolet (UV) screens are increasingly used as a result of growing concern about UV radiation and skin cancer; they are also added to cosmetics and other products for light stability. Recent data...Full Text Available
BackgroundPreclinical studies indicate that the enzyme cyclooxygenase 2 plays an important role in ultraviolet-induced skin cancers. We evaluated the efficacy and safety of celecoxib,...Full Text Available
This work deals with a rational vision of stratospheric ozone including the threats on ozone layer, the verifications and the fears. After a recalling on the ozone layer history, the authors treats the question of the ultraviolets particularly the beneficial effects. Then an explanation of the ozone layer decrease is given. (O.L.). 29 refs., 6 figs.
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
The effects of fine-particle C, such as diesel soot, on the optical properties of urban haze in the visible wavelength range were explored to determine the dominant effects and to see if simple parameters (such as visual range in green) provide an adequate measure of these effects. It is known that fine-particle C absorbs more strongly in the blue than in the red, so that when it is mixed with a white pigment, the resulting gray can appear somewhat brown. The possibility of a similar effect in urban hazes was investigated, but found not to occur. When the sun is overhead, the near-horizon sky chromaticities caused by mixtures of fine-particle C and non-absorbing aerosol can also be produced by non-absorbing aerosols alone. It is shown that absorbing aerosol will darken the horizon sky, and a simple equation for the radiance of the horizon sky is derived. The effect of absorbing ...
For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the ...
This patent describes a process for removing carbon dioxide from a feed stream of natural gas having at least methane, ethane and heavier. It comprises: first, separating the feed stream in a first separator to form a first stream having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane and a second stream, having methane, carbon dioxide and ethane; separating the second stream in a second separator into a stream of carbon dioxide product and a third stream having ethane, methane and carbon dioxide: mixing at least a portion of the third stream with a polar compound; stream after the mixing in an absorber; separating the vapor and liquid of the third stream after the mixing in an absorber; absorbing the remaining unabsorbed carbon dioxide in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane with the ...
A shock absorber mechanism and method for use on the leg structure of a jack-up offshore drilling rig is described. It is mounted on the bottom of each existing leg of a drilling rig and comprises a pointed piston member which is positioned on the bottom of the leg structure and projects downwards through the can/footing of the rig leg. The piston member is held in place by a resilient tension member which is designed to absorb shock forces during vertical/axial impact of the leg structure when contact is made with the ocean floor. (author).
Use of hydrogen absorbing alloys in various practical applications is always connected with the problem of production of starting alloys. The transition from laboratory samples to small-scale production involves the change of furnace and its operation mode and this has an effect on the preparation method of mixture of starting metal. Also, for some applications such as thermosorption compressors the exact values of thermodynamical parameters of reaction are needed. In the present work we present the results of investigation of series Laves phase hydrogen-absorbing alloys which can be promising in for use in different devices. 1 ref.
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it ...
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...
Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for production of Ta, Hf and Lu radioisotopes by (d,x) reactions were ...
The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.
This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a ...
Abstract The characteristics of desulfurization and denitrification with composite absorbent were researched through aqueous absorption experiments. The removal efficiencies of SO2 and NO were up to 100 and 95%, respectively. The composite absorbent included NaClO2 and component M. Existence of component M in the solution could reduce the absorbent cost compared with using sodium chlorite alone. Chlorine dioxide, as main reaction intermediate product, participated in oxidation reaction. The optimal experimental conditions involved NaClO2 concentration of1.13 mmol/L, solution pH of 5.5, molar ratio (M/NaClO2) of 4.1, reaction temperature of 323 K. The optimal solution pH and reaction temperature were both in the required ranges of limestone-gypsum wet flue gas desulfurization (FGD) process....
In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and impact tests are described. (Auth.).
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally ...
Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally ...
Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...
Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.
Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)
With conventional heating process, ultraviolet (UV) illumination, and microwave irradiation, we have successfully synthesized UV curable encapsulating adhesives with excellent gas barrier capabilities, good adhesive strength, moderate hardness, and high refractive indices. The experimental results manifest that the physical properties of lab-made encapsulating adhesives are highly dependent on their chemical structures and synthetic procedure. We also discover that the encapsulating adhesive prepared by microwave irradiation (i.e. encapsulating adhesive VI-MW) exhibits better adhesive strength and higher gas resistance than those prepared by conventional heating process and UV illumination. Furthermore, encapsulating adhesive VI-MW has also been applied for the package of organic light emi...
The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.
A composition and method for encapsulating a photovoltaic device which minimizes discoloration of the encapsulant. The composition includes an ethylene-vinyl acetate encapsulant, a curing agent, an optional ultraviolet light stabilizer, and/or an optional antioxidant. The curing agent is preferably 1,1-di-(t-butylperoxy)-3,3,5-trimethylcyclohexane; the ultraviolet light stabilizer is bis-(N-octyloxy-tetramethyl) piperidinyl sebacate and the antioxidant is selected from the group consisting of tris (2,4-di-tert-butylphenyl) phosphite, tetrakis methylene (3,5-di-tert-butyl-4-hydroxyhydrocinnamate) methane, octadecyl 3,5-di-tert-butyl-4-hydroxyhydrocinnamate, and 2,2'-ethylidene bis(4,6-di-t-butylphenyl) fluorophosponite. The composition is applied to a solar cell then cured. The cured product contains a minimal concentration of curing-generated chromophores and resists UV-induced degradation.
As research for the chemical properties of lanthanide molecules in the dry system, electrochemical and ultraviolet-visible optical measurements on the chloride molten salt system have been conducted at Research Reactor Institute, Kyoto University. The reduction behavior of Ln(III)-Ln(0) and Ln(II) are measured on La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, and Yb by the cyclic voltammetry. The molar absorption coefficients of the f-f transition are measured by the measurement of ultraviolet-visible absorption spectra on Pr, Nd, Ho and Gd. From the comparison of the optical data between wet and dry systems, the characteristics of photon absorption are discussed in the molten salt. (H. Katsuta)
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a ...
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, ...
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...
Epidermal gamma delta T cells (γδ T) and Langerhans cells (LC) are immune cells altered by exposure to ultraviolet radiation (UVB), a powerful stressor resulting in immune suppression....Full Text Available
The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.
Governments around the world will soon make decisions on policies that could determine the fate of the ozone layer-the Earth's shield from harmful ultraviolet radiation. The Vienna Convention for the Protection of the Ozone Layer, signed on March 22, 1985, created a framework for scientific cooperation and information exchange that will form the basis for a protocol for controlling substances thought to threaten the ozone layer. As of mid-1987, 29 countries had signed the Convention, including the major producers and users of chlorofluorocarbons (CFCs), the most important of suspect chemicals.
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
Polyacrylonitrile films have been spin cast and pyrolyzed to produce thin (500--1500 A) carbon films. These films have higher electrical conductivities than films produced by other methods at similar temperatures. The conductivity can be varied by at least four orders of magnitude by changing the pyrolysis temperature. Ultraviolet, infrared, and Raman spectroscopies were used to investigate the chemical structure of the films during different stages of processing.
The general n-point massless p-adic Feynman amplitude with arbitrary parameters of analytic regularization for each line is calculated. This result is presented in the form of a sum over hierarchies of a given graph. The structure of ultraviolet and infrared divergences of p-adic Feynman amplitudes is characterized and the star-triangle uniqueness identity in the p-adic case is derived. (orig.).
The synthesis, crystal structure, thermal stability and absorbance spectra of perovskite-type oxynitrides with the general formula SrTi1-xNbx(O,N)3 (x=0.05, 0.10, 0.20, 0.50, 0.80, 0.90, 0.95) have been investigated. Oxide samples were prepared by a polymerized complex synthesis route and post-treated under ammonia at 850 oC for 24 h to substitute nitrogen for oxygen. Synchrotron X-ray powder diffraction (XRD) evidenced that the mixed oxide phases were all transformed into oxynitrides with perovskite-type structure during a thermal ammonolysis. SrTi1-xNbx(O,N)3 with compositions x?0.80 crystallized in a cubic and samples with x?0.90 in a tetragonal structure. The Rietveld refinement indicated a continuous enlargement of the lattice parameters towards higher niobium content of the samples. Thermogravimetric analysis (TGA) and hotgas extraction revealed the dependence of the nitrogen incorporation upon the degree of niobium substitution. It showed that more nitrogen ...
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for ...
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there was no improvement in the mechanical properties, and using acrylamide the ...
We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alpha particle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alpha particle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.
The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.
Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
The Bureau of Mines performed chemical research to elaborate details of sulfur chemistry pertaining to the citrate flue gas desulfurization process in which sulfur dioxide (SO2), absorbed (as bisulfite ion) in a buffered sodium citrate solution, is reduce...
Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major ...
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
Photon migration provides sensitive tissue oximetry in which the optical pathlength is known. Phase array gives the precise location of a subnanomolar amount of hidden absorber in highly scattering medium. PMID:8079713
Only half of the carbon dioxide produced by burning fossil fuels stays in the atmosphere. It is thought that the oceans absorb the rest. To understand the world's climate it is necessary to know how the atmosphere, ocean and biosphere interact.
A process is described for removing carbon dioxide from a feed stream of natural gas, having at least methane, ethane and heavier hydrocarbon, comprising: separating the feed stream in a first separator to form a first stream, having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane, and a second stream, having methane, carbon dioxide and ethane; mixing the second stream with a polar compound to form a third stream; separating the vapor and liquid of the third stream in the bottom portion of an absorber; absorbing carbon dioxide and ethane from the separated vapor of Step C in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane forming a fourth stream; separating the ethane from the polar compound and carbon dioxide in a separator; separating the first stream in a third separator to separate the propane and heavier ...
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Gun barrel vibrations lead to dispersion in the shot patterns. Thus, reducing these vibrations should lead to increased accuracy. Since the muzzle is the anti-node for all vibration modes and its vibrations have the greatest effect on shot dispersion, it ...
It is answered to a previous letter by Basano, and shown that the difficulties met by that author within ''Extended relativity'' do not exist, but are due to the erroneous assumption that a certain condition for tachyons to be absorbed by a macro-object is sufficient (whilst it is only a necessary one).
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
nsive neutron-absorbing bricks from commercially available CaB/sub 6/ powder. The bricks are 2 x 3 x 5 in., and are strong enough to withstand normal handling. They last indefinitely; the ones described are now 7 years old, used and stored under normal room temperatures and humidities. The procedure is to make a thick, dry mud with the powder and water, followed by compression in a mold at pressures of about 1 ton/in./sup 2/ or more. The bricks are then baked for 2 hours or longer at a temperature of about 750 deg C. (auth)
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
This dissertation deals with membrane gas absorption in the application of CO{sub 2} removal by aqueous alkanolamines, using microporous PTFE hollow fiber membranes. A new lab-scale apparatus was constructed and an extensive experimental study executed to determine the performance of the membrane gas absorber, with aqueous solutions of monoethanolamine (MEA) and methyldiethanolamine (MDEA) as absorbents. The important operation parameters CO{sub 2} partial pressure, gas velocity, liquid velocity, temperature and liquid CO{sub 2} loading were systematically varied within the range typically experienced in a process for exhaust gas CO{sub 2}-removal
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize the output energy. ...
Ultraviolet (UV) upconversion (UC) luminescence in Yb3+/Er3+-codoped yttrium oxide (Y2O3) nanocrystals can be enhanced by orders of magnitude via tridoping further with Li+ ions under diode laser excitation of 970 nm. Sensitized three-photon UC radiations at 390 and 409 nm, corresponding to the 4G11/2?4I15/2 and 4H9/2?4I15/2 of Er3+ ions, respectively, present an enhancement time of about 33 times, which is larger than the 24 times enhancement for the UC green radiation. The UV UC radiation at 320 nm that corresponds to the 2P3/2?4I15/2 of Er3+ ions has also been greatly enhanced. Theoretical calculations interpret that all the observed enhancement times of UV UC radiations arise from the prolonged lifetimes of their intermediate states.
This work estimates the power requirements for using photochemical processes driven by space nuclear power to counteract the Earth's ozone layer depletion. The total quantity of ozone (O_3) in the Earth's atmosphere is estimated to be about 4.7 x 10"3"7 molecules. The ozone production and destruction rates in the stratosphere are both on the order of 4.9 x 10"3"1 molecules/s, differing by a small fraction so that the net depletion rate is about 0.16 to 0.26% per year. The delivered optical power requirement for offsetting this depletion is estimated to be on the order of 3 GW. If the power were produced by satellite reactors at 800 km altitude (orbit decay time #approx# 300 years), some means of efficient power beaming would be needed to deliver the power to stratospheric levels (10--50 km). Ultraviolet radiation at 140--150 nm could have higher absorption rates in O_2 (leading to production of atomic oxygen, which can combine with O_2 to form O_3) than in ozone ...
The second list of objects in the Second Biurakan Spectral Sky Survey of the region centered on alpha 09h50m, delta +55 deg 00 arcmin is given. The list contains data on 110 objects and galaxies of a peculiar physical nature and 24 blue stars. The observations were made with the 40-52 arcsec Schmidt telescope of the Biurakan Astrophysical Observatory with a set of three objective prisms using Kodak IIIaJ and IIIaF emulsions sensitized in nitrogen. The area is found to contain 20 quasar candidates and four Seyfert galaxies, 27 blue stellar objects, 24 galaxies with an appreciable ultraviolet continuum, and 39 emission galaxies without appreciable ultraviolet radiation. The surface brightness of the quasars and Seyferts on the considered area down to the limiting magnitude 19.5 M is more than 1.5 per square degree with allowance for the already known quasars. The surface density of emission galaxies is about four per square degree. 7 references.
Marmesin was isolated from the medicinal plant, Afraegle paniculata. Its cytotoxicity and mutagenicity in Chinese hamster V79 cells when sensitized to near ultraviolet (NUV) and long wavelength ultraviolet light or black light (BL) were assayed. Marmesin was extremely cytotoxic in the dark. This cytotoxicity was photoenhanced in NUV and BL; the photoenhanced lethality being higher in NUV than in BL. The LD/sub 50/ of marmesin under NUV and BL photosensitization were 0.002 ..mu..M and (0.012 ..mu..M), respectively. In the absence of NUV and BL, marmesin's LD/sub 50/ was 0.013 ..mu..M.NUV and BL without marmesin were not significantly cytotoxic at the fluence rates of 0.29 W/m/sup 2/ and 4.2 W/m/sup 2/, respectively, for up to 20 min. In contrast to the observed high cytotoxicity of marmesin, its mutagenicity at the HGPRT locus (Asub(z)Gsup(r)) was weak. The implication of this result in the high incidence of skin cancer in Nigeria in ...
We present the general properties of the far-ultraviolet (FUV; 1370-1720A) continuum background over most of the sky, obtained with the Spectroscopy of Plasma Evolution from Astrophysical Radiation instrument (SPEAR, also known as FIMS), flown aboard the STSAT-1 satellite mission. We find that the diffuse FUV continuum intensity is well correlated with N_{HI}, 100 $\\mu$m, and H-alpha intensities but anti-correlated with soft X-ray. The strongest correlation is with the H-alpha emission, and the correlation of the diffuse background with the direct stellar flux is weaker than the correlation with other parameters. The continuum spectra are relatively flat. However, a weak softening of the FUV spectra toward some sight lines, mostly at high Galactic latitudes, is found not only in direct-stellar but also in diffuse background spectra. The diffuse background is relatively softer that the direct stellar spectrum. We also find that the diffuse FUV background averaged ...
Multilayer mirror coatings which reflect extreme ultraviolet (EUV) radiation are a key enabling technology for EUV lithography. Mo/Si multilayers with reflectances of 67.5% at 13.4 nm are now routinely achieved and reflectances of 70 2% at 11.4 nm were obtained with MO/Be multilayers. High reflectance is achieved with careful control of substrate quality, layer thicknesses, multilayer materials, interface quality, and surface termination. Reflectance and film stress were found to be stable relative to the requirements for application to EUV lithography. The run-to-run reproducibility of the reflectance peak position was characterized to be better than 0.2%, providing the required wavelength matching among the seven multilayer-coated mirrors used in the present lithography system design. Uniformity of coating was improved to better than 0.5% across 150 mm diameter substrates. These improvements in EUV multilayer mirror technology will enable us to meet the stringent ...
Ethidium bromide (EB) and ultraviolet light (UV) in combination are known to produce a synergistic induction of 'petite' mutants in yeast. Two other agents were combined with EB, 3-Carbethoxypsoralene (3 CPs) activated by 365 nm light or #gamma# rays. EB in combination with 3 CPs also resulted in an enhanced production of 'petite' mutants. After the photoaddition of 3 CPs in exponential phase cells, recovery of the 'petite' mutation during dark liquid holding was inhibited by the presence of EB producing an enhanced number of 'petite' mutants. The behavior of mitochondrial antibiotic resistance markers after individual and combined treatments with EB and 3 CPs indicates a random loss of markers after EB and a preferential loss of a certain region for the 3 CPs photoaddition. The combination of the two agents leads to an additivity of total drug marker losses rather than a synergistic loss. The combination of EB with #gamma# rays produced no enhancement in 'petite' ...
Nanocrystalline ZnO films were fabricated via a simple method involving the oxidation of Zn films at a remarkably low temperature of 380 C. X-ray diffraction study confirmed that the Zn films were completely oxidized even at the low temperature of 380 C and the ZnO films fabricated were of polycrystalline wurtzite structure. Room temperature optical pumping using a frequency-quintupled Q-switched Nd:YAG laser ({lambda}=213 nm) exhibited that sharp peaks at around 3.12 eV emerged above excitation powers of {proportional_to}7 MW/cm{sup 2}, demonstrating lasing in the ZnO films. These results represent that the process is a simple, promising approach for fabricating ZnO of sufficient optical performance for use as ultraviolet (UV) light emitters and an alternative UV laser source; both are key components in short-wavelength photonic devices. (orig.)
Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those at the temperature of interest because of ...
Electronic circular dichroism (ECD) of the n-#pi# and #pi# -#pi# transitions of the amide groups in the ultraviolet has become an indispensable tool for qualitative characterization of proteins in solution. Since the existence of such a spectrum (that is, of natural optical activity) comes from the three dimensional interaction of the chromophores in the molecule, CD is exquisitely sensitive to molecular conformation. However, in proteins, the amide transitions available in the near UV are limited in number and are broads and overlapping. Interactions among them yield information about the polymeric backbone, but since such amide electronic excitation are relatively delocalized, the resulting
An electroweak model with running coupling constants described by an energy dependent entire function is utraviolet complete and avoids unitarity violations for energies above 1 TeV. The action contains no physical scalar fields and no Higgs particle and the physical electroweak model fields are local and satisfy microcausality. The $W$ and $Z$ masses are compatible with a symmetry breaking $SU(2)_L\\times U(1)_Y \\rightarrow U(1)_{\\rm em}$, which retains a massless photon. The vertex couplings possess an energy scale $\\Lambda_W > 1$ TeV predicting scattering amplitudes that can be tested at the LHC.
The Drell-Yan mechanism for the production of lepton pairs is one of the most basic processes for physics studies at hadron colliders. It is therefore important to have accurate theoretical predictions. In this work we compute the two-loop virtual mixed QCD x QED corrections to Drell-Yan production. We evaluate the Feynman diagrams by decomposing the amplitudes into a set of known master integrals and their coefficients, which allows us to derive an analytical result. We also perform a detailed study of the ultraviolet and infrared structure of the two-loop amplitude and the corresponding poles in epsilon.
This paper reports on the results of experiments into efficient higher-order anti-Stokes Raman conversion of tunable short-pulse XeCl laser radiation. The maximum output energy of the pumping laser, in which the radiation of a frequency-doubled dye laser is amplified by two XeCl laser amplifiers, is 55 mJ with a pulse duration of 1 ns FWHM. Using hydrogen gas as a Raman medium, a series of anti-Stokes lines up to the 12th order (121.5 nm) is generated in the vacuum ultraviolet (VUV) region. 16 references.
The effect of UV radiation in the wavelength region 230 nm to 302 nm on the ability of an irradiated mammalian cell to reactivate UV-irradiated mammalian virus was tested. An action spectrum for radiation enhanced reactivation (RER) is presented. The shape of the action spectrum points to a combined nucleic acid-protein target for UV radiation effects on this cellular parameter. An analysis of the results of others involving the biochemical and photobiological events involved in RER does not allow us to distinguish which macromolecule is the major contributor to this effect. Studies involving an analogous phenomenon in bacteris (Weigle reactivation) imply that RER and WR amy involve similar mechanisms. (author).
The color centers, which are generated in yttrium-aluminium perovskite (YAP):Nd(1 at.%) and YAP:Er(50 at.%) crystals under the influence of ultraviolet and #gamma#-irradiation, have been studied by absorption spectroscopy. The generated color centers are both stable and transient at room temperature. It is shown that the transient color centers are mainly responsible for the decrease of laser generation efficiency of Nd:YAP and YAP:Er irradiated crystals, although physical mechanisms leading to efficiency decrease are different in these materials. (orig.)
We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.
Tb3+-activated Sr3AlO4F phosphors were synthesized by a high-temperature solid-state reaction method. The investigation of photoluminescence and cathodoluminescence indicates that these phosphors can be effectively excited by ultraviolet light and low-voltage electron beam. The phosphors exhibit a tunable-green emission. The luminescence behaviors are explained by the site occupancy of Tb3+ ions in the host crystal and the cross-relaxation of 5D3 to 5D4 state.
Tb3+-activated Sr3AlO4F phosphors were synthesized by a high-temperature solid-state reaction method. The investigation of photoluminescence and cathodoluminescence indicates that these phosphors can be effectively excited by ultraviolet light and low-voltage electron beam. The phosphors exhibit a tunable-green emission. The luminescence behaviors are explained by the site occupancy of Tb3+ ions in the host crystal and the cross-relaxation of 5D3 to 5D4 state.
In situ optical absorption spectroscopy was used to study the generation of E' centres in amorphous SiO_2 occurring by photo-induced breaking of Si-H groups under 4.7eV pulsed laser radiation. The dependence from laser intensity of the defect generation rate is consistent with a two-photon mechanism for Si-H rupture, while the growth and the saturation of the defects are conditioned by their concurrent annealing due to reaction with mobile hydrogen arising from the same precursor. A rate equation is proposed to model the kinetics of the defects and tested on experimental data.
Pollen from four temperate-latitude taxa were treated with UV radiation in a portion of the UV-B (280-320 nm) waveband during in vitro germination. Inhibition of germination was noted in this pollen compared to samples treated identically except for the exclusion of the UV-B portion of the spectrum. Levels similar to maximum solar UV-B found in temperate-latitude areas failed to inhibit pollen germination significantly, while levels similar to maximum solar UV-B found in equatorial alpine locations caused partial inhibition of germination in three of the four taxa examined.
We studied the optimum plasma conditions that are required for efficient high-order harmonic generation in platinum plume. Harmonics up to the 49th order (?=16.32 nm) are analyzed under various conditions of laser-plasma interaction. Time-resolved ultraviolet spectra of platinum plasma at both optimum and nonoptimum conditions of harmonic generation are presented. We calculated the ionization states of the plasma, free electron density, and singly charged ion density at different prepulse intensities and compared them with experimental results.
Laser gain of the NIJI-IV compact storage-ring-based Free Electron Laser (FEL) system at AIST reached #approx#9% at 200 nm for an average beam current of 16.3 mA. In addition to such a drastic gain enhancement, improvement of the laser-cavity performance has led to successful FEL lasing in the vacuum ultraviolet below 200 nm even in a compact system. Temporal and spectral characteristics of the NIJI-IV FEL were examined around 200 nm. FEL performance will be briefly discussed from the application point of view.
We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.
As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this study is to determine whether any mercury is released into the atmosphere when the ...
We derive stellar masses, ages, and star formation histories (SFHs) of massive early-type galaxies in the z = 1.237 RDCS1252.9-2927 cluster and compare them with those measured in a similarly mass-selected sample of field contemporaries drawn from the Great Observatories Origin Deep Survey South Field. Robust estimates of these parameters are obtained by comparing a large grid of composite stellar population models with 8-9 band photometry in the rest-frame near-ultraviolet, optical, and IR, thus sampling the entire relevant domain of emission of the different stellar populations. Additionally, we present new, deep U-band photometry of both fields, giving access to the critical far-ultraviolet rest frame, in order to empirically constrain the dependence of the most recent star formation processes on the environment. We also analyze the morphological properties of both samples to examine the dependence of their scaling relations on their mass ...
Behavioral detection of a low-frequency (40 Hz) vibratory dipole at source distances of 1.5–24 cm was measured by classically conditioned respiratory suppression in goldfish (Carassius...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
Since current microbiology methods are not suitable to detect Clostridium perfringens in formalin-fixed, paraffin-embedded tissue samples, we developed a PCR assay to detect toxin-encoding...Full Text Available
Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available
Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection...Full Text Available
on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...
Due to the serovar diversity in Haemophilus (H.) parasuis, it is difficult to develop a universal serological method for detection of this pathogen....Full Text Available
Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification ...
Palladium chloride films have been found to be useful as ... when suitably prepared palladium chlo- ride films are exposed ... Like the palladium chloride ( PdCl2) ...
BackgroundAutofluorescence bronchoscopy is more sensitive than conventional bronchoscopy for detecting early airway mucosal lesions. Decreased specificity can lead...Full Text Available
Accelerated aging tests on tin-oxide-coated anodized aluminium selective absorber surfaces have been performed. It is shown that the tin oxide layer provides excellent protection for the anodized surface. The thermal stability of the double layer is equal to, or better than, the stability of the bare anodized surface. Both surfaces degrade very slowly at 450deg C. The anodic layer is porous and therefore not very scratch resistant and it degrades when exposed to humidity, both acidic and alcaline. It is shown that the tin oxide film, which is hard and chemically very stable, almost completely protects the anodized surface from chemical degradation. The mechanical wear resistance is also considerably improved. The optical selectivity does not quite match that of the the anodized surface, but the remarkable stability together with the solar parameters of {alpha}=0.91 and hemispherical emittance {epsilon}= 0.16 (normal emittance {epsilon}{sub n}=0.12) make this ...
A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained from this migration technique. They present examples of the application of the new migration method to synthetic seismic data where P-P reflections ...
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical properties. The discrete ordinate model has been used to assess the influence of ...
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations due to energy straggling in ...
Peeled Avena sativa coleoptile sections have been used to study the control of solute uptake under conditions where the uptake is not limited by the cuticular barrier. In the presence of 2% sucrose, auxin enhances the rate at which the total osmotic solutes increase, but this appears to be a response to the increased growth rate, inasmuch as the auxin effect is eliminated when growth is inhibited osmotically. When sections are incubated in sucrose or in 10 millimolar NaCl, the osmotic concentration increases until a plateau is reached after 8 to 24 hours. Auxin has no effect on the initial rate of increase in osmotic concentration. This difference in steady-state osmotic concentration is, in part, a response to auxin itself, as it persists when auxin-induced growth is inhibited osmotically. The upper limit for osmotic concentration does not appear to be determined by the turgor pressure, inasmuch as a combination of sucrose and NaCl gave a higher plateau osmotic concentration than did ...
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related ...
The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO{sub 2} emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO{sub 2} removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were ...
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the absorption process ...
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the ...
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative process is described for operation of the ...
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
Labelling of "1"4C-M-ISP and its absorption, translocation and distribution in peanut and soybean seedling were studied. The results of experiments showed that the radioactive substance could be translocated in xylem and phloem of two kinds of plants. The root of peanut seedling absorbed "1"4C-M-ISP from the nutrient solution more strong than the root of soybean seedling did. After leaf treatment with "1"4C-M-ISP, the soybean seedling absorbed more radioactive substance than peanut seedling did. But the translocation's speed of radioactive substance in pnloem of two kinds of plants were similar.
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
The Monte-Carlo transport code MCNP was used to evaluate possible arrangements of cores for the MIT Reactor using monolithic LEU fuel. Plate and moderator thicknesses were varied, and fixed absorbers and inner reflectors added in an effort to maximize available neutron fluxes at in-core and ex-core locations of experimental facilities. Addition of D_2O in the H_2O moderator was also evaluated. Comparisons of the fast, epithermal, and thermal fluxes were made at selected locations. Keff was also evaluated and critical blade heights compared with the existing HEU core. Results indicate that the LEU fluxes could approach HEU values with the use of a fueled in-core experimental facility, a fixed boron absorber spider and an inner beryllium reflector. (author)
In this work, a comprehensive model has been developed for the absorption of carbon dioxide into promoted hot potassium carbonate solution. The model, which is based on penetration theory, incorporates an extensive set of important reactions and takes into account the coupling between mass transfer and chemical kinetics. The penetration theory provides an appropriate absorption rate and enhancement factor for the chemical absorption. Operating data for carbon dioxide absorption into DEA-hot potassium carbonate solution has been compared with model predictions. The impact of parameters such inlet temperature of lean solution, promoter concentration, liquid split fraction, hot feed location and type of promoter on the performance of a split-flow absorber have been examined. The use of other promoters is an efficient way to enhance the carbon dioxide absorption, which has been discussed in this paper.
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as ...
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...
Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for cultured blue pearls. (author).
Forced harmonic vibration of a non-uniform elastic beam with attached dynamic vibration absorbers (DVA) is studied. Analytical approximation of the solution is obtained by the functional perturbation method (FPM). The problem has application to cutting tools operations where the resistance of the tool holder against regenerative chatter can be enhanced by optimizing the real part of the frequency response function (FRF). A test case of a beam with step-like heterogeneity and single DVA at the tip shows that the FPM solution is very accurate for up to ?40 percent deviation in both stiffness and mass density. Using the analytical results and Sims approach, optimal DVA tuning is found for each set of beam heterogeneity parameters by solving a set of nonlinear algebraic equations numer...
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied by measuring absorption rates in a single wetted-sphere ...
The nature and relationship of methane to coal mines is discussed and sources of information are outlined. Methods of gas analysis in general and methods for the detection of methane in use in coal mines are described. Methods of remote detection of gases and those that have application for use in underground coal mining operations are discussed. The report represents recommendations on remote methane detection systems that may find application in underground coal mines. (20 refs.)
Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, the infrared ...
The methods introduced for the field of cleaning waste water can be classified under various processes. Chemical oxidation is done with ozone, hydrogen peroxide and ultraviolet irradiation with subsequent biological decomposition. Another method is ultra-filtration with recovery of valuable materials or waste water ponds with algae biomass to decompose ammonium compounds, nitrates and phosphates. (EF) [Deutsch] Die auf dem Gebiet der Abwasserreinigung vorgestellten Methoden kann man in verschiedene Verfahren einordnen. Die chemische Oxidation erfolgt mit Ozon, Wasserstoff-Peroxid, UV Bestrahlung und anschliessenden biologischen Abbau. Eine andere Methode ist die Ultrafiltration mit Rueckgewinnung von Wertstoffen oder Abwasserteiche mit Algenbiomasse zum Abbau von Ammoniumverbindungen, Nitraten und Phosphaten. (EF)
A scheme of evaluating a generalized three-photon excitation cross section #sigma#/sub (3)/ in neutral atomic argon at 3144.67 A is outlined. Three photons at this wavelength can excite the neutral argon atoms from the ground 3p"6 "1S_0 state to the 3p"54s'[1/2]_1"0 state. The fourth photon will ionize the argon atoms. Assuming linear polarization of the incident laser radiation, contributions from several channels in various energy-level schemes are summed in the evaluation of the transition probability. For a laser linewidth of #DELTA##lambda#/sub L/ = 1 A, our maximum numerical value of the computed result for the three-photon excitation cross section is #sigma#/sub (3)/ = 1.414 x 10/sup -80/ cm"6 s"2. .AE.
The effects of eight chemicals on the inactivation rate of ultraviolet radiation on the colony building capabilities of two strains of Saccharomyces cervisae - a wild type strain and a mutant deficient in excision repair - were studied. The insecticide methoxychlor, the herbicide 2,4-dichlorophenoxyacetic acid, the fungicide pentachlorophenol and its metabolite tetrachlorohydroquinone, as well as the chemicals acrylonitrile and 2,3-dichloro-1-propene have no significant impact on the effects of UV radiation in Saccharomyces cerevisae. Depending on the concentration, trichloroethylene increases the sensitivity to UV radiation. The herbicide paraquat provides efficient protection against UV radiation at concentrations where a toxic effect cannot be observed even without UV. The results were rather similar for both strains. (orig.).
Ultraviolet photoelectron spectra were measured for vanadyl phthalocyanine (VOPc) ultrathin films prepared on graphite to study effects of the molecular orientation and the electric dipole layer on the organic electronic states. VOPc has a permanent electric dipole perpendicular to the molecular plane, hence a well-defined electric dipole layer could be intentionally prepared by using the oriented monolayer. The observed binding-energy difference of the highest occupied molecular orbital (HOMO) bands between the oriented monolayer and the double layer was found to agree with the vacuum level shift, leading to a conclusion that the molecular energy level with respect to the substrate Fermi level is changed when the molecule is in the electric dipole layer.
We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a stable cation.
A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.
The light-emitting properties of cubic silicon carbide films grown by vacuum vapor phase epitaxy on Si(100) and Si(111) substrates under conditions of decreased growth temperatures (T gr ? 900?700?C) have been discussed. Structural investigations have revealed a nanocrystalline structure and, simultaneously, a homogeneity of the phase composition of the grown 3C-SiC films. Photoluminescence spectra of these structures under excitation of the electronic subsystem by a helium-cadmium laser (?excit = 325 nm) are characterized by a rather intense luminescence band with the maximum shifted toward the ultraviolet (?3 eV) region of the spectral range. It has been found that the integral curve of photoluminescence at low temperatures of measurements is split into a set of Lorentzian components. Th...
The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.
Oxide charge on the sidewalls of SiO{sub 2} embedded silicon wires with 20x20 nm{sup 2} cross section is shown to influence the Schottky barrier height for Pd{sub 2}Si/Si junctions positioned on the end surfaces of the wires. Compared with results on planar silicon surfaces, the electron barrier height is 0.3 eV lower for wires investigated as fabricated. By increasing the oxide charge through irradiation by ultraviolet light, the electron barrier decreases by an additional 0.15 eV and the hole barrier correspondingly increases by about the same amount. The phenomenon is explained by assuming an oxide charge density in the range of 10{sup 12} cm{sup -2}.
Zooplankton tolerant to ultraviolet radiation (UVR) could be indirectly affected by UVR through interactions with UV-sensitive species in the same ecosystem. In Lake Giles, Pennsylvania, USA, the calanoid copepod Leptodiaptomus minutus is more UVR tolerant than the cohabiting species Daphnia catawba and Cyclops scutifer. We asked whether L. minutus is affected by UV-induced mortality of a food competitor (D. catawba) or a predator of its nauplii (C. scutifer). We conducted two in situ enclosure experiments with six treatments: L. minutus alone, L . minutus + Daphnia and L. minutus + Cyclops in the presence and absence of UVR. There were few differences in survival among treatments in Experiment 1, which had enhanced food and a cumulative UVR (320 nm) dose of 9.3 kJ m-2. In Experiment 2, wh...
Hemolysis induced by long-wave ultraviolet radiation (UVA) and 8 different commercial tetracycline derivatives was studied in a model using human red blood cells. Demethylchlortetracycline and doxycycline were shown to have pronounced hemolytic properties causing 88% and 85% hemolysis, respectively, at a concentration of 50 micrograms/ml and 72 J/ cm2 of UVA. Tetracycline, oxytetracycline, and chlortetracycline caused maximally 18% hemolysis at 200 micrograms/ml and lymecycline only 7% at 100 micrograms/ml. Methacycline showed intermediate hemolytic effect of 36% at 200 micrograms/ml. Minocycline had no hemolytic effect whatsoever. These experimental data correlate very well with clinical reports and comparative phototoxicity trials in humans. Photohemolysis may thus be of value for predicting tetracycline phototoxicity.
Luminescence properties of SiAlON phosphors codoped with Ca and Yb were investigated by changing the host lattice composition. These modifications of the host lattice were obtained by replacing Si-N bonds by Al-N and Al-O bonds. Their photoluminescence (PL) and cathodoluminescence (CL) properties were measured and compared with each other. PL allows observing the influence of the host lattice modifications by measuring wider areas. CL can excite all luminescent centers, in particular the UV luminescence centers, even if their amount is small. Thus, two additional peaks in the ultraviolet and infrared regions were observed in CL, which is not observed by PL. This work suggests that the combination of PL and CL gives more understanding about the luminescence of SiAlON phosphors, in particular the role of the secondary phases on their properties.
Cold spray was employed as a novel low temperature approach to deposit titanium dioxide (TiO{sub 2}) photocatalytic film. The film microstructure was characterized using X-ray diffraction and scanning electron microscopy. The photocatalytic performance was examined through acetaldehyde degradation under ultraviolet illumination. Results showed that TiO{sub 2} film was successfully deposited on substrate surface through cold spray. The film thickness reached up to 15 {mu}m. The film presented a rough surface and porous structure. Owing to the low temperature of spray powder, no phase and particle size changes occurred to TiO{sub 2} during deposition. It was found that the cold-sprayed TiO{sub 2} film was active for photodegradation of acetaldehyde.
The kinetics of alkaline hydrolysis of methylparathion was studied at different temperatures (0-50 Centigrade) in the p H range of 8-12 by ultraviolet-visible absorption spectroscopy. Optimum p H and wavelength conditions were defined to carry out the simultaneous determination of methylparathion and one of its hydrolysis product, paranitrophenol, in buffered aqueous medium. Based on the experimental data and the mathematical equation of the kinetics, a rate constant (k) of first-order and an activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author) activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author)
We review and extend in several directions recent results on the asymptotic safety approach to quantum gravity. The central issue in this approach is the search of a Fixed Point having suitable properties, and the tool that is used is a type of Wilsonian renormalization group equation. We begin by discussing various cutoff schemes, i.e. ways of implementing the Wilsonian cutoff procedure. We compare the beta functions of the gravitational couplings obtained with different schemes, studying first the contribution of matter fields and then the so-called Einstein-Hilbert truncation, where only the cosmological constant and Newton's constant are retained. In this context we make connection with old results, in particular we reproduce the results of the epsilon expansion and the perturbative one loop divergences. We then apply the Renormalization Group to higher derivative gravity. In the case of a general action quadratic in curvature we recover, within certain approximations, the known ...
The intrinsic fluorescence of clear amniotic fluid from third-trimester pregnancy is reported. The fluorescence intensity peaked at 405 nm when excited by ultraviolet light in the range of 310 to 360 nm. All of the 33 samples tested fluoresced, and their emission spectrum had the same shape, varying only in magnitude. Changing sample temperature (20 to 50 C) and sample pH (7.2 to 7.7) had little effect on the emission spectrum. The same fluorescence, with higher intensity, was observed when some newborn urine was tested. The fluorescence of amniotic fluid may provide a new tool to determine fetal age, fetal organ maturation, and fetal distress. (author).
The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.
Iron nanoparticles were produced using extracts of green tea leaves (GT-Fe NPs). The materials were characterized using TEM, SEM/EDX, XPS, XRD, and FTIR techniques and were shown to contain mainly iron oxide and iron oxohydroxide. The obtained nanoparticles were then utilized as a Fenton-like catalyst for decolorization of aqueous solutions containing methylene blue (MB) and methyl orange (MO) dyes. The related experiments investigated the removal kinetics and the effect of concentration for both MB and MO. The concentrations of dyes in aqueous solution were monitored using ultraviolet-visible (UV-vis) spectroscopy. The results indicated fast removal of the dyes with the kinetic data of MB following a second order removal rate, while those of MO were closer to a first order removal rate. T...
Plasma polymerization of aniline is carried out in a radiofrequency plasma reactor and the effect of polymerization time is examined in the structural, optical and optoelectronic properties of deposited films. Conjugated structures of polyaniline like films are obtained with unique and broad optical absorption band in the ultraviolet and entire visible region. The width of the absorption band increases and hence the optical band gap decreases with polymerization time. The optical constants are extracted by Swanepoel method and the optical dispersion parameters are determined by employing the Wemple-DiDomenico single oscillator model. The films exhibit similar thermal stability in air and argon atmosphere in the region of interest for optoelectronic applications. The photoluminescence study...
Organic/metal interface properties are of high interest for the application of molecular (sub)monolayers to modify surface properties. They are applied for, e.g., molecular electronics, chemical sensing, or the tuning of injection barriers in organic electronic devices. We present a joint theoretical and experimental study of F{sub 4}TCNQ adsorbed on Cu(111). The electronic and structural properties were determined by ultraviolet photoelectron spectroscopy (UPS) and X-ray standing wave (XSW) measurements. To better understand the complex process of binding, we modelled the system using density-functional theory. We find forward-donation from the lone pairs of the molecule into metallic states and back-donation from the metal into the LUMO of the molecule. The data on Cu(111) are compared to F4TCNQ on Au(111) and Ag(111) as well as to investigations of pyrenetetraone on various coinage metals.
#epsilon#_m(Ce"4"+) values of the ceric-cereus system have been measured and the experimental procedure is described. Both routine titration method and electrochemical measurement were used. Some interference factors, such as ultraviolet, acidity and temperature, were studied as well. The temperature coefficient of #epsilon#_m(Ce"4"+) value in this experiment is about -0.1% degree C"-"1. A statistic analysis was made for 24 experimental values of #epsilon#_m(Ce"4"+) and a Gaussian distribution was found. Ultimately, an average molar extinction coefficient of 553.2 +- 1.3 m"2#centre dot#mol"-"1 was obtained at #approx#320 nm in 0.4 mol/L H_2SO_4 system, with a relative standard deviation of 0.24% (95% confidence level) and a total uncertainty of 1.5%.
A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.
The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.
Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.
Background. Reports of positive patch test and photopatch test reactions to the chemical ultraviolet filter octocrylene have increased during the last decade. Little is known about the reason for octocrylene's allergenic activity. Objectives. To present and discuss the results of patch tests and photopatch tests with octocrylene, and to investigate the possible cause of its allergenic properties. Methods. Results of patch tests and photopatch tests with octocrylene in patients with adverse skin reactions to sunscreen products and/or ketoprofen were collected. The allergenic potency of octocrylene was investigated in the murine local lymph node assay (LLNA). Chemical reactivity assays were used to mimic octocrylene's interaction with biomolecules. Results. We report 23 cases of positive tes...
Composting of sawdust and paper mill sludge, using a 'Kneer' process reactor, was studied in an attempt to elaborate upon organic matter transformation during the process and to define parameters to measure the compost maturity level. Temperature, electron paramagnetic resonance data, ash and C, H, N and S contents, and a spectroscopic method using ultraviolet-visible (UV-VIS) for alkaline (pH = 8.5) and solid samples was used to study the maturity of the compost samples. These parameters were measured in 6 humic acids extracted from the compost samples during 29 days. The results of this work show that the 'Kneer' process is efficient in transforming ligno-celulitic residues in a short time (29 days), into an organic fertilizer material with application perspectives (author)
Absorption coefficient data are presented for molecular oxygen at temperatures between 1100 and 2000K and discrete wavelengths between 211 and 235nm. Measurements were made behind reflected shock waves using broad-linewidth ultraviolet laser radiation generated from a frequency-quadrupled, tunable, pulsed Ti:Sapphire laser. Test mixtures consisting of 15% O"2, 15% He and balance Ar were used to minimize the influence of vibrational relaxation on the reflected shock temperature. The experimental results are in good agreement with theoretical calculations and confirm that discrete features from the Schumann-Runge system dominate between 211 and 235nm at temperatures higher than 1100K.
Spiral orbit tribometry friction tests performed on Ni-rich Ni55Ti45 titanium ball bearings indicate that this alloy is a promising candidate for future aerospace bearing applications. Microstructural characterization of the bearing specimens was performed using transmission electron microscopy and energy dispersive spectroscopy, with NiTi, Ni4Ti3, Ni3Ti, and Ni2Ti4Ox phases identified within the microstructure of the alloy. Density functional theory was applied to predict the electronic structure of the NixTiy phases, including the band structure and site projected density of states. Ultraviolet photoemission spectroscopy was used to verify the density of states results from the density functional theory calculations, with good agreement observed between experiment and theory.
Studies of asphalt emulsion sealants conducted by the Pacific Northwest Laboratory have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to near background levels. Field tests at the tailings pile in Grand Junction, Colorado, confirmed that an 8-cm admix seal containing 22 wt% asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and compacted, overburden was applied over the seal to protect the seal from ultraviolet degradation.
Studies of asphalt emulsion sealants have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to less than background levels. Field tests at the tailings pile in Grand Junction, Colorado confirmed that an 8-cm admix seal containing 22 wt % asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and conpacted, overburden was applied over the seal to protect the seal from ultraviolet degradation. 14 figures.
For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability between the metal mold and the compact. (author)
An electrochemical biosensor for determination of hydrogen peroxide (H2O2) was fabricated, based on the electrostatic immobilization of horseradish peroxidase (HRP) with one-dimensional gold nanowires (Au NWs) and TiO2 nanoparticles (nano-TiO2) on a gold electrode. The nano-TiO2 can give a biocompatible microenvironment and compact film, and the Au NWs can provide fast electron transferring rate and greatly add the amount of HRP molecules immobilized on the electrode surface. Au NWs were characterized by ultraviolet?visible spectra and transmission electron microscope. The electrode modification process was probed by cyclic voltammetry and electrochemical impedance spectroscopy. Chronoamperometry was used to study the electrochemical performance of the resulting biosensor. Under optimal co...
There are several methods of generating OH free radicals from ozone and/or hydrogen peroxide and ultraviolet light. They all have in common that the OH free radicals originate in one single source only whereas in the combination of ozone with ionizing radiation two simultaneous working sources for the OH free radicals exist. The resulting higher OH free radical concentration makes this process especially apt for the remediation of low level contaminated groundwater as for example trichloroethylene (TCE) contamination in the sub-ppm range. A cost comparison between O_3/UV and O_3/electron beam for remediation of a groundwater contaminated with 100 ppb TCE indicated that for a throughput of about 5 million gallons/day the O_3/electron beam process is more cost-effective. (authors).
A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...
Supplemental criticality safety analysis of a pool type storage for TRIGA spent fuel at 'Jozef Stefan' Institute in Ljubljana, Slovenia, is presented. Previous results (Ravnik, M, Glumac, B., 1996) have shown that subcriticality is not guaranteed for some postulated accidents. To mitigate this deficiency, a study was made about replacing a certain number of fuel elements in the rack with absorber rods (Glumac, B., Ravnik, M., Logar, M., 1997) to lower the supercriticality probability, when the pitch is decreased to contact (as a consequence of a severe earthquake) in a square arrangement. The criticality analysis for the hexagonal contact pitch is presented in this paper, following the same scenario as outlined above. The Monte Carlo computer code MCNP4B with ENDF-B/VI library and detailed three dimensional geometry was used. First, the analysis about the influence of the number of triangular fuel piles on the bottom that could appear, if the fuel rack, made of ...
The equilibrium dynamic capacity of polymer materials based on 2,4,6-triamino-1,3,5-triazine has been determined. The possibility of their application as absorbents of sulfur dioxide from exhaust gases has been shown.
We used fast absorbance spectroscopy to investigate in vivo binding dynamics and electron transfer between plastocyanin (pc) and photosystem I (PSI), and cytochrome (cyt) f...Full Text Available
This study investigated relationships between molecular weight distributions of unreduced grain proteins and grain, flour, and end-use quality characteristics of soft white winter wheats grown in Oregon. Absorbance area and area % values of protein fractions separated by size exclusion HPLC (SE-HPL...
In this note we prove to all orders in the small scale expansion that all off-shell parameters which appear in the chiral effective Lagrangian with explicit DELTA(1232) isobar degrees of freedom can be absorbed into redefinitions of certain low-energy constants and are therefore redundant.
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
This paper advances hypotheses on the chemistry of the interaction of thorium and yttrium with organic-inorganic salts of molybdenum polyacids. On the basis of an analysis of the data of an adsorption experiment and the quantitative relationships that follow from the law of mass action, it is shown that thorium is absorbed by the solid phase by coprecipitation with the participation of complex formation, while the coprecipitation of yttrium with salts of polyacids is due to a reaction of ion exchange chemisorption.
We report the oxygen, hydrogen, and deuterium effects on nitrogen implantation of stainless steel. Oxygen is absorbed on the surface creating a potential barrier and diminishing the nitrogen retention. Deuterium removes more oxygen from the surface than hydrogen, augmenting the nitrogen chemical potential and yielding faster nitrogen diffusion into the bulk material.
... Biodegradable plastics have the potential to be used in various flushable sanitary product applications such as sanitary towels, colostomy bags and other absorbent products. In addition, effluent from recycling activities must be treated in wastewater treatment plants and may contain biodegradable plastics. Flushable biodegradable plastics can have an adverse impact on wastewater treatment plants due to the very fast throughputs, typically 4 to 8 hours, from the drain to the plant. This length of time is insufficient for many biodegradable plastics to lose their structure. Such plastics can ...
The invention deals with an offshore drilling or production platform in particular designed for quake-active areas. The platform rests on the sea bed with a low-gravitational weight and anchored to stabilized pile foundations absorbing the horizontal and vertical acting forces from earthquakes. The platform including pillars can be made of different materials, prestressed concrete in particular. 3 figs.
The loosening equipment consists of a base machine and four-link suspension mechanism which is a cross frame with loosening gear connected to the base machine by universal hinges. In order to improve the reliability of the machine, the drive of transverse shifting in the cross frame is made of symmetrically arranged, shock-absorbing, hydraulic cylinders which are connected by additional universal hinges to the base machine and the lower pull rods. The design of the loosening machine guarantees its reliable operation on soil with significant quantity of hard inclusions.
Threshold pump intensity values leading to irreversible damage to colored laser elements based on elastic polymers were measured. The damage to colored elastomers is connected with absorbing microinclusions but is independent of molecular absorption. It is shown that damage to the elastomers has a pronounced threshold character in contrast to the microdamage accumulation effect in glassy polymers. The damage threshold for elastomers is 1.5 times higher, which is connected with the absence of microstresses (characteristics for organic glasses) in the specimens. 13 references.
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
In this article, equations of motion of a manipulator are derived after consideration of the characteristics of the driving source. By considering a collision between a link and an object, and considering the active motion to absorb the kinetic energy of the object, the trajectories for saving energy are calculated by the iterative dynamic programming (IDP) method. The dynamic characteristics of manipulator control based on the trajectory for saving energy are also analyzed theoretically and investigated experimentally.
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ionization chamber. The ...
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...
Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...
The water soluble, photolabile nitrene precursor, azidonaphthalene-2,7-disulfonic acid (ANDS) was encapsulated in small unilamellar, isoelectric (egg PC) or negatively charged (egg PC + dihexadecylphosphate) liposomes. The individual and combined effects of heme-proteins and UV irradiation on the fluorescence of these vesicles under aerobic conditions were studied. Consistent with the catalytic action of heme-proteins on lipid peroxidation and peroxide decomposition, addition of cytochrome c (positively charged) or catalase (negatively charged) to the vesicles elicited immediate formation of a fluorescence band at 470 nm, characteristic of Schiff bases that form from aldehyde byproducts of decomposing hydroperoxides. Ultraviolet irradiation of liposomes caused no significant changes in the fluorescence spectrum, in spite of the radiolysis of ANDS inside the vesicles with consequent formation of nitrene radicals. When isoelectric vesicles were irradiated with UV ...
In order to follow some of the changes induced by ultraviolet-B (UV-B, 280-320 nm) radiation in Phaseolus vulgaris and Brassica napus, experiments were designed to localize sites of changes in leaves and to correlate some of the physiological and biochemical changes with penetration of UV-B radiation. B.napus was exposed to 8.9 kJ m"-"2 day"-"1 biologically effective UV-B radiation (UV-B_B_E). The penetration of UV-B radiation into the leaf was followed using a quartz fibre optic microprobe. Monochromatic radiation at 310 nm was decreased by ca 50 and 34% in the adaxial and abaxial epidermis, respectively, in plants not exposed to UV-B, whereas the radiation was decreased by ca 70 and 42%, respectively, in the same region in UV-treated plants. Polychromatic radiation showed a wavelength dependent change mainly for the collimated radiation. The results correlated with the distribution of phenolic compounds analysed from 40 #mu#m paradermal leaf sections. The first ...
We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with GaN. The ...
We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with GaN. The advantages of In_xAl_yGa_1_-_x_-_yN quaternary over ...
The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV ...
Scrotal skin of black Long-Evans rats and human thigh skin were maintained in vitro as organ cultures for as long as 14 days, and examined histologically using the combined skin splitting and Dopa techniques. Selected rat skin cultures received testosterone in the culture medium and/or were irradiated with ultraviolet light (290 to 320 nm uvl). With increased time in culture, scrotal melanocytes round up and there is an increase in epidermal pigmentation. Human skin behaves similarly; after eight days in vitro human melanocytes also become rounded, but remain strongly Dopa-positive. Addition of exogenous testosterone to cultured rat skin maintains dendritic morphology of melanocytes, but cell body size is still reduced. uvl irradiation stimulates melanocytes in rat skin cultures, maintaining their dendritic morphology and increasing epidermal and dermal pigmentation. Cultured skin receiving both uvl and testosterone illustrates a synergistic effect. Electron ...
We report on the ultraviolet laser absorption spectroscopy of atomic Gd at 394-554 nm where two transition lines are place very closely by using a frequency-doubled beam of external-cavity diode laser (ECDL). One is from 999.121 to 26337.071 cm-1 and the other from 0 to 25337.755 cm-1. If two transition lines are placed closely within a continuous fine tuning range, the real-time measurement of the atomic excitation temperature is possible without any significant time consumption because at least two transition lines originating from different low-lying energy levels need to be investigated for the Boltzmann-plot. Since the spectral difference between the two transitions is only about 0.195 cm-1 (5.85 GHz), it is possible to record both the absorption spectra simultaneously as shown in Fig. 1. But the transition probabilities (or oscillator strengths) of these lines have not been measured accurately yet to the best of our knowledge. We report on the newly measured ...
The Westinghouse Electric Corporation has undertaken to investigate, develop, and characterize laser-assisted processing techniques utilized to produce the fine line, thin metal grid structures that are required to fabricate high-efficiency solar cells. Two basic techniques for metal deposition will be investigated, as follows: (1) photochemical decomposition of liquid or gas phase organometallic compounds utilizing either a focused, CW ultraviolet laser (System 1) or a mask and ultraviolet flood illumination, such as that provided by a repetitively pulsed, defocused excimer laser (System 2), for pattern definition, and (2) thermal deposition of metals from organometallic solutions or vapors utilizing a focused, CW laser beam as a local heat source to draw the metallization pattern. The purpose of this contract is to investigate the various existing laser-assisted film deposition techniques in order to develop a new, cost-effective technology ...
Glycosaminoglycan synthesis was studied in cell populations of ultraviolet light-induced murine cutaneous fibrosarcoma cells under conditions of varying growth rates in vitro. After labeling with the precursors, /sup 3/H-glucosamine and /sup 35/SO/sub 4/, sulfated glycosaminoglycans recoverable by direct proteolysis of the culture monolayers increased approximately 5-fold on a per cell basis from sparsely populated, exponential cell cultures (greater than 85% of cells in S, G2, or M phases) to stationary cultures inhibited by high cell density (greater than 50% of cells in G1). Within this cell surface-associated material, the relative ratio of heparan sulfate to the chondroitin sulfates was approximately 60/40% under conditions of exponential growth; in the growth-arrested cultures, the reverse ratio was found. The substratum attached material, obtained from the flask surface after ethyl glycol bis(beta-aminoethyl ether)-N,N'-tetraacetic acid ...
Benzene molecules , present in the proto-planetary nebula CRL 618, are ionized and dissociated by ultraviolet (UV) and X-ray photons originated from the hot central star and by its fast wind. Ionic species and free radicals produced by these processes can lead to the formation of new organic molecules. The aim of this work is to study the photoionization and photodissociation processes of the benzene molecule, using synchrotron radiation and time-of-flight mass spectrometry. Mass spectra were recorded at different energies corresponding to the vacuum UV (21.21 eV) and soft X-ray (282-310 eV) spectral regions. The production of ions from the benzene dissociative photoionization is here quantified, indicating that C_6H_6 is more efficiently fragmented by soft X-ray than UV radiation, where 50% of the ionized benzene molecules survive to UV dissociation while only about 4% resist to C-rays. Partial ion yields of H and small hydrocarbons, such as C_2H_2"+, C_3H_3"+, ...
Since antioxidants have been shown to play a major role in preventing some of the effects of aging and photoaging in skin, it is important to study this phenomenon in a controlled manner. This was accomplished by developing a simple and reliable in vitro technique to assay antioxidant efficacy. Inhibition of peroxidation by antioxidants was used as a measure of relative antioxidant potential. Liposomes, high in polyunsaturated fatty acids (PUFA), were dispersed in buffer and irradiated with ultraviolet (UV) light. Irradiated liposomes exhibited a significantly higher amount of hydroperoxides than liposomes containing antioxidants in a dose- and concentration-dependent manner. Lipid peroxidation was determined spectrophotometrically by an increase in thiobarbituric acid reacting substances. To further substantiate the production of lipid peroxides, gas chromatography was used to measure a decrease in PUFA substrate. In order of decreasing antioxidant effectiveness, ...
A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.
BackgroundEpilepsy is a common neurological disorder characterized by recurrent electrophysiological activities, known as seizures. Without the appropriate detection strategies,...Full Text Available
A commercially available synthetic nucleic acid probe (SNAP) conjugated to alkaline phosphatase was compared with standard culture techniques for detecting Campylobacter species. The SNAP was able to...Full Text Available
This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.
To understand the function of edges in perception of moving objects, we defined four questions to answer. Is the focus point in visual motion detection of a moving object: (1) the body or the edge of...Full Text Available
The W-259 project will provide upgrades to the 2706-T/TA Facility to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. The project provides decontamination activities supporting the environmental restoration mission and waste management operations on the Hanford Site.
Dental caries continues to be a common chronic disease among various population groups. Patient care can be improved with detection at the earliest stage. However, current techniques do not...Full Text Available
PurposeSatisfaction of search (SOS) occurs when an abnormality is missed because another abnormality has been detected. This research studied whether the severity...Full Text Available
A rapid, sensitive, and simple method was developed to detect the sapstain fungi Ophiostoma piceae and O. quercus in stained wood. By using microwave heating for DNA...Full Text Available
We have evaluated the performance of two rapid, low-cost methods for the detection of ofloxacin (OFX) resistance with 95 Mycobacterium tuberculosis isolates from countries with high...Full Text Available
Data on a technique for the detection of antigen from arthropod vectors in a dot immunobinding assay are presented. In this system, antigen present in the vector was first solubilized in sodium dodecyl...Full Text Available
Randomly amplified polymorphic DNA (RAPD) analysis and the PCR assay were used in combination with dilution plating on a semiselective medium to detect and enumerate propagules of Trichoderma...Full Text Available
... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ...
A latex agglutination (LA) test was evaluated for the detection of human rotaviruses in stool specimens. Both antiserum and immunoglobulin G (IgG)-sensitized latex particles were used, with IgG-coated...Full Text Available
A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay...Full Text Available
PurposeThe aim of this investigation was to exploit lens-specific glycated crystallins as an immunogen to detect human glycated crystallins and their circulating autoantibodies in...Full Text Available
SynopsisEarly detection of late onset neonatal sepsis, prior to obvious and potentially catastrophic clinical signs, is an important goal in neonatal medicine. Sepsis causes a...Full Text Available
With the advent of dense maps of human genetic variation, it is now possible to detect positive natural selection across the human genome. Here we report an analysis of over 3 million polymorphisms...Full Text Available
The genetic systems of bacteria that have the ability to use organic pollutants as carbon and energy sources can be adapted to create bacterial biosensors for the detection of industrial pollution....Full Text Available
Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw ...
OBJECTIVE: To evaluate the commercial microparticle enzyme immunoassay (MEIA), Abbott IMx Select Chlamydia, for the detection of Chlamydia trachomatis in women and to compare its performance with endocervical...Full Text Available
We compared MRSA Select to mannitol-salt agar with 8 μg/ml cefoxitin for the detection of methicillin-resistant Staphylococcus aureus (MRSA) from 6,199 clinical...Full Text Available
The aim of this study was to evaluate a nitrate reductase assay (NRA) performed on smear-positive sputa for the direct detection of rifampin resistance in Mycobacterium tuberculosis....Full Text Available
The direct detection of pyrazinamide resistance in Mycobacterium tuberculosis is sufficiently difficult that many laboratories do not attempt it. Most pyrazinamide resistance is caused...Full Text Available
Endocervical swabs from 212 women and urethral swabs from 100 men were tested by the routine methods for McCoy cell culture and simultaneously by a novel enzyme amplified immunoassay test to detect...Full Text Available
We have discovered interstellar rubidium by observing the resonance line of Rb I at 7800 A toward zeta Oph. This is the heaviest element yet detected within the interstellar medium, and our detection of this element is important for understanding the history of nucleosynthesis in the solar neighborhood.
Objectives. We investigated increases in diarrheal illness detected through syndromic surveillance after a power outage in New York City on August 14, 2003.Methods....Full Text Available
A serodiagnostic test has been developed for the detection of Plasmodium falciparum in infected blood. Using parasite antigens and infected red blood cells from in vitro...Full Text Available
A serological trapping technique for detecting rotaviruses is described which involves coating electron microscope grids with protein A and specific rotavirus antiserum. The presence of a layer of antibodies...Full Text Available
The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and dose responses of the human cultured leukemia (HL-60) line were measured...Full Text Available
PCR was used with the primer pair VANS1-NS21 to detect the arbuscular mycorrhizal fungus Glomus intraradices (commercial inoculum source) on roots of lettuce, zinnia, leek, pepper, and endive plants....Full Text Available
A sensitive assay based on the polymerase chain reaction for the detection of Ockelbo virus RNA was developed. Two primer pairs from the gene coding for the E2 glycoprotein were chosen. By use of a...Full Text Available
Colonies of toxin-producing Pasteurella multocida were detected with peroxidase-labeled monoclonal antibodies by a membrane assay. Examination of the specificity of the assay with 29 P. multocida cultures...Full Text Available
Since bearing is in wide use as basic parts for rotary machines, detection and diagnosis of its defects are important in practical use. To discriminate defect portions by early detection of roller bearing flaking, the conventional parameter method using peakedness is poor. Thus to directly obtain difference in waveform, the new method was applied to such detection which uses KDI as the scale of a difference in waveform, and a most neighborhood classification rule based on KDI. The detection and discrimination abilities of this method was studied mainly in experiment. The experiment used a bench scale rotor and a supporting bearing, and attempted detection and discrimination of no flaking, outer ring flaking and inner ring flaking. As a result, this method could detect and discriminate fine flaking which was never detected by conventional ...
Real-time PCR has the potential to streamline detection and identification of Cryptosporidium spp. in human clinical samples. In the present...Full Text Available
A nonmammalian test system for germ-cell mutagenesis has been developed by using the Japanese medaka fish. We describe a system for detecting DNA alterations in F1 progeny descended from the gamma-irradiated...Full Text Available
Background/AimsThe findings of several recent studies suggest that antinuclear antibodies (ANAs) are frequently detected in patients with acute hepatitis A (AHA). However, the clinical...Full Text Available
In this paper the authors prove a uniqueness theorem for the electric detection of cavities in a three dimensional solid from Cauchy data measured on the surface. The cavities, finite in number, are assumed to be insulating. The surfaces of the cavities are assumed to be smooth on the complement of a set that is, in some sense, negligible. (orig.)
Discrete masses are commonly detected during mammographic screening and most such lesions are benign. For lesions without pathognomonically benign imaging features that are still regarded likely to...Full Text Available
We prepared polyclonal antibody specific to Mycoplasma pneumoniae and examined the conditions influencing the ability of an indirect immunofluorescence test to detect the specific antigen in respiratory...Full Text Available
A sensitive and specific detection method was developed for Xanthomonas hyacinthi; this method was based on amplification of a subsequence of the type IV fimbrial-subunit gene fimA...Full Text Available
There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available
BackgroundThe commonest pathogenic DMD changes are intragenic deletions/duplications which make up to 78% of all cases and point mutations (roughly 20%) detectable...Full Text Available
We proposed a faster pedigree-based generalized multifactor dimensionality reduction algorithm, called PedG-MDR II (PII), to detect gene-gene interactions underlying complex traits. Inherited...Full Text Available
A duplex TaqMan real-time RT-PCR assay was developed for the detection of California (CAL) serogroup viruses and Cache Valley virus (CVV), for use in human surveillance. The targets selected...Full Text Available
Synthetic complementary oligonucleotides are useful hybridization probes for the detection of mRNAs and genes encoding proteins for which only a partial amino acid sequence is known. Usually this involves...Full Text Available
The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.
Sep 16, 2010 ... Taking military operations as an example, there is evidence that stress-related behavioral disorders and mental conditions such as anxiety, ...
Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).
This invention relates to new phosphor materials and to combinatorial methods of synthesizing and detecting the same. In addition, methods of using phosphors to generate luminescence are also disclosed.
In this paper, we first discuss the detection of supernova neutrino on Earth. Then we propose a possible method to acquire information about $\\theta_{13}$ smaller than $1.5^\\circ$ by detecting the ratio of the event numbers of different flavor supernova neutrinos. Such an sensitivity cannot yet be achieved by the Daya Bay reactor neutrino experiment.
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.
The indirect detection of particle dark matter (DM) is based on the search for anomalous components in cosmic rays (CRs) due to the annihilation of DM pairs in the galactic halo, on the top of the standard astrophysical production. These additional exotic components are potentially detectable at Earth as spectral distortions for the various cosmic radiations: $\\chi + \\chi \\to q \\bar{q}, W^+ W^-, ... \\to \\bar{p}, \\bar{D}, e^+ \\gamma and \
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
We sequenced 16S rRNA genes from the vaginal swab contents of a postmenopausal woman with asymptomatic bacterial vaginosis (BV). Sequences from Atopobium vaginae were the most commonly detected. In a survey of 35 other postmenopausal women, this organism was detected in 44% with BV but not in any subjects deemed healthy. PMID:15071062
Surveillance of a population, such as a weapon stockpile, is needed to discover manufacturing defects as well as deterioration as the population ages. This article considers the risks of sampling rates for surveillance from three perspectives: detection probability of defects in a proportion of a population with pass/fail data, detection of a trend in a defective proportion of the population with pass/fail data, and detection of a trend with quantitative degradation measurements. Understanding of these risks will help the decision maker choose a sampling rate to protect against such problems of a specified size at a tolerable risk.
The objective of this paper is to perform an impact analysis of the Interim Storage Cask (ISC) of the Fast Flux Test Facility (FFTF) for a 4-ft end drop. The ISC is a concrete cask used to store spent nuclear fuels. The analysis is to justify the impact force calculated by General Atomics (General Atomics, 1994) using the ILMOD computer code. ILMOD determines the maximum force developed by the concrete crushing which occurs when the drop energy has been absorbed. The maximum force, multiplied by the dynamic load factor (DLF), was used to determine the maximum g-level on the cask during a 4-ft end drop accident onto the heavily reinforced FFTF Reactor Service Building`s concrete surface. For the analysis, this surface was assumed to be unyielding and the cask absorbed all the drop energy. This conservative assumption simplified the modeling used to qualify the cask`s structural integrity for this accident condition.
Fuel assemblies in a reactor pressure vessel are disposed in a reactor core shroud. The own weight of the fuel assembly is supported by a reactor core support plate, and is supported, for the horizontal direction, by an upper lattice plate and the reactor core support plate. A support portion for the upper portion of the fuel assembly is disposed above the fuel assembly, and a support portion for the support portion described above is joined to a shroud head by welding. The support portion for the upper portion of the fuel assembly has a network-like portion which absorbs and disperses rising force which exerted on the fuel assembly when the fuel assembly is risen by seismic forces. The rising force exerted on the fuel assembly absorbed by the network-like portion is effectively transferred to the shroud head by the support portion. With such a constitution, rising of the fuel assembly can be prevented against the seismic vibrations having ...
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and dosimeter weight, were ...
The paper gives results of a study to identify active sites and surface functional groups that may contribute to the absorption of elemental mercury (Hg) by relatively inexpensive calcium (Ca)-based sorbents. The study investigated the formation of chlorine (Cl) sites in CA-based sorbents as well as their role and reactivity in the absorption of Hg. HCl-exposed calcium sulfate dihydrate (gypsum) exhibited a superior Hg sorption capability. Crystalline water molecules on the surface of the gypsum were confirmed to contribute indirectly to Hg uptake. These surface molecules may have absorbed HC1 through hydrogen bond formation between an oxygen atom of a crystalline water molecule and a hydrogen atom of an HCl molecule. Two adjacent, physically absorbed HCl molecules could then trap an Hg molecule through formation of a mercuric-chloride-like molecule. Significant correlations between Cl and Hg uptake by gypsum were noted.
The paper gives results of a study to identify active sites and surface functional groups that may contribute to the absorption of elemental mercury (Hg) by relatively inexpensive calcium (Ca)-based sorbents. The study investigated the formation of chlorine (Cl) sites in CA-based sorbents as well as their role and reactivity in the absorption of Hg. HCl-exposed calcium sulfate dihydrate (gypsum) exhibited a superior Hg sorption capability. Crystalline water molecules on the surface of the gypsum were confirmed to contribute indirectly to Hg uptake. These surface molecules may have absorbed HC1 through hydrogen bond formation between an oxygen atom of a crystalline water molecule and a hydrogen atom of an HCl molecule. Two adjacent, physically absorbed HCl molecules could then trap an Hg molecule through formation of a mercuric-chloride-like molecule. Significant correlations between Cl and Hg uptake by gypsum were noted.
Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)
Products having balanced melting point and decomposition temperature have been developed by employing nylon 6T fundamental molecular structure and selected copolymer components, Arlen being one of the products. It has heat resistance as good as that of super-engineering plastics, low water absorption, and excellent cost-performance which can be used for normal injection molding machines. The unit price per kilogram is low when its high heat resistance is taken into consideration. The coefficient of water absorption is as low as about 1/3 of that of nylon 66, and it can be considered to be a low water absorbing amide. The molding temperature is from 320[degree]C to 350[degree]C, the decomposition temperature is 395[degree]C at 2% weight decreasing temperature, and normal injection molding can be employed. It has excellent soldering resistance, high temperature rigidity, dimensional stability, water absorbing coefficient, as well as good chemical ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and phosphorus were studied at MURR. The screen thickness and the neutron ...
Ordered mesoporous C-TiO2 nanocomposites with crystalline framework were prepared by the evaporation-induced triconstituent co-assembly method. The products were characterized by XRD, TEM, N2 adsorption-desorption and TG. Their microwave absorption properties were investigated by mixing the product and epoxy resin. It is found that the peak with minimum reflection loss value moves to lower frequencies and the ordered mesoporous C-TiO2 nanocomposite possesses an excellent microwave absorbing property with the maximum reflection loss of -25.4 dB and the bandwidth lower than -10 dB is 6.6 GHz. The attenuation of microwave can be attributed to dielectric loss and their absorption mechanism is discussed in detail. The mesoporous C-TiO2 nanocomposites also exhibit a lower infrared emissivity in the wavelength from 8 to 14 ?m than that of TiO2-free powder. -- Graphical abstract: Ordered mesoporous C-TiO2 nanocomposite with crystalline framework possess excellent microwave ...
A method of treating final products from a flue gas desulfurization. The flue gas desulfurization is carried out by the absorption of sulfur oxide in a spray dryer with a suspension which contains lime, or in a reactor with a dry, fine-grained, absorbent which contains lime. Prior to desulfurization, the fly ash carried along by the flue gas which is to be desulfurized is separated entirely, partially, or not at all from the flue gas, and the final products from the flue gas desulfurization, prior to any further treatment thereof, amount to 1-99% by weight, preferably 1-70% by weight, of fly ash, and 1-99% by weight, preferably 30-99% by weight, of the sum of the desulfurization products, preferably calcium sulfite hemihydrate, and/or calcium sulfite, and/or calcium sulfate dyhydrate, and/or calcium sulfate hemihydrate, and/or calcium sulfate, as well as residue of the absorbent. The reduction of the amount of calcium sulfite is implemented by ...
During the past decades polymer membrane technology has been applied in various industries for a myriad of separation duties. They are also an important candidate for the solution of separation problems associated with the recovery of carbon dioxide in power plants. The application of membrane technology for carbon dioxide removal is discussed for two different ways of operation in present and future power plants. First, pressure driven operations are discussed, followed by a discussion of the use of membranes in absorbers. The pressure driven processes based on currently available gas separation membranes are shown to have poor separation characteristics. Further membrane development work appears to be necessary, especially in the area of temperature resistant membranes. Membrane selectivity goals are presented for present and future power plants. Membrane absorbers making use of commercially available absorption liquids and membranes possess ...
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for some of the most frequent radiopharmaceutical examinations, together with the absorbed ...
A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon dioxide is used and toluene is added. These conditions have the following favourable effects: (I) significant size reduction of ...
A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis by basic catalyst, ...
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform ...
the cotton leaf worm, Spodoptera littoralis (boisd.) were irradiated with 100,150 and 200 Gy to induce inherited sterility. the effects of the tested doses applied to these pupae through three consequent fillial generations and the retarded influence on their F_1,F_2 and F_3 generations progeny were examined . irradiation of parental male induced damage to their daughter females ovaries. the overioles of females among P_1 ,F_1 and F_2 generations showed that the follicular epithelial cells appeared abnormal beside their limited separation from developing oocytes which became shrinked, semi absorbed or completely absorbed leaving vacuoles. the nurse cells were reduced or absent in some parts. damage was obvious through the first and second generations especially at 150 and 200 Gy. in the third generation, ovaries were not greatly affected
The Fresnel solar collector is a promising concept to reduce the electricity cost price in solar thermal power plants. The optical performance of a Fresnel collector depends on material properties, on its geometric layout and on the level of optical accuracy that can be obtained. A variety of geometric parameters, e.g. the height of the absorber, the number, size and distance of primary mirrors in.uence the shading and blocking of rays and the amount of rays missing the absorber. To evaluate the in.uence of the parameter variation regarding the electricity cost price and to yield an optimization, the optical performance is assessed with an annual simulation based on hourly weather-data. To permit a consideration of changes in collector cost according to different geometric layouts, cost factors where allocated to geometric parameters. The paper presents the method and the simulation results of the optimization under different boundary ...
It is very well known that the CANDU reactor has positive Coolant Void Reactivity (CVR), which is most important criticisms about CANDU. The most recent innovations based on using a thin absorbent Hafnium shell in the central bundle element were successfully been applied to the Advanced CANDU Reactor (ACR) project. The paper's objective is to analyze elementary lattice cell effects in applying such methods to reduce the CVR. Three basic fuel designs in their corresponding geometries were chosen to be compared: the ACR-1000TM, the RU-43 (developed in INR Pitesti) and the standard CANDU fuel. The bundle geometry influence on void effect was also evaluated. The WIMS calculations proved the Hafnium absorber suitability (in the latest 'shell design') to achieve the negative CVR target with great accuracy for the ACR-1000 fuel bundle design than for the other two projects. (authors)
The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities have been noticed after 83 days storage at room temperature ...
The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even after 5 h of thermal treatment, the ...
Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. This irradiation ...
Stainless steel is pickled in pickling bath with the sulfuric acid and a mixture of hydrofluoric acid and nitric acid. Suitable equipment based on speedy and accurate chemical analysis for actual production lines has not been developed yet. The concentration of sulfuric acid can be analyzed by using the neutralization titration method. As a method of analyzing hydrofluoric acid in the mixed acid, the iron-acetylacetone complex discoloration absorbance method was adopted. For the concentration, of nitric acid, the method of subtracting the concentration of hydrofluoric acid from the total mixed acid amounts obtained by neutralization titration is adopted. Furthermore, the iron-salicylic acid complex absorbance method is adopted as a method of analyzing the iron content. By adopting these methods, the fully automated analyzer is developed. Completing analysis work can be shortened to 40 minutes by automated sampling from the acid pipes. The fully ...
Burnable poisons are used in nuclear reactors to produce a more level distribution of power in the reactor core and to reduce to necessity for a large control system. An ideal burnable poison would burn at the same rate as the fuel. In this study, separation of neutron-absorbing isotopes was investigated in order to eliminate isotopes that remain as absorbers at the end of fuel life, thus reducing useful fuel life. The isotopes Gd-157, Dy-164, and Er-167 were found to have desirable properties. These isotopes were separated from naturally occurring elements by means of plasma separation to evaluate feasibility and cost. It was found that pure Gd-157 could save approximately $6 million at the end of four years. However, the cost of separation, using the existing facility, made separation cost- ineffective. Using a magnet with three times the field strength is expected to reduce the cost by a factor of ten, making isotopically separated burnable ...
Introduced herein is microwave irradiation for the adsorption and desorption of environmental pollutants. Microwaves may be used in two ways, other than through elevation of temperature of a system as a whole with the adsorbent such as activated carbon serving as the heating medium. The first is the application by which desorption is caused to take place of specified molecules. For example, zeolite that has adsorbed water is regenerated when it is irradiated with microwaves in a stream of cooling gas. This is because only the moisture is heated since zeolite is a non-carbon adsorbent that absorbs microwaves but a little. Another case is reported in which microwaves are utilized to desorb H2S, H2O, CO, etc., from molecular sieves. In the second application, coexisting materials different in absorptivity are exposed to irradiation. The adsorption of microwave-absorbent materials is inhibited while that of the others is accelerated. For example, ...
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with the dependence of ...
This project is concerned with the structure and function of the unique antenna system found in the green photosynthetic bacteria. The antenna system in these organisms is contained within a vesicle known as a chlorosome, which is attached to the cytoplasmic side of the cell membrane. Additional antenna pigments and reaction centers are contained in integral membrane proteins. Energy absorbed by the bacteriochlorophyll c (BChl c) pigments in the chlorosome is transferred via a ``baseplate`` array of BChl a antenna pigments into the membrane and to the reaction center. This system is similar in some respects to the phycobilisome antenna system found in cyanobacteria and some types of algae, in that a membrane-associated structure absorbs light and transfers it to the membrane where conversion to chemical energy takes place. However, the overall structure, the type of pigments utilized and the nature of the proteins in these two types of ...
The COBE data on cosmic background radiation (CBR) isotropy and spectrum are generally considered to be explicable only in the context of the Big Bang theory and to be confirmation of that theory. However, this data can also be explained by an alternative, non-Big Bang model which hypothesizes an intergalactic radio-absorbing and scattering medium. Dense, force-free magnetic filaments generated by quasars, active galactic nuclei and Herbig-Haro objects can remain stable in the intergalactic medium for many Gy. They will be opaque to radiation with wavelengths longer than 100--400 microns, and essentially transparent to shorter wavelengths. They are thus capable of thermalizing and isotropizing the cosmic background radiation, and of accounting for the observed decrease of radio luminosity of galaxies within increasing distance from earth. A simple, inhomogeneous model of such an absorbing medium can reproduce both the isotropy and spectrum of ...
Abstract BACKGROUND: Nitrate leaching and the resulting groundwater contamination from intensive cereal production has become a major concern for long-term farmland efficiency and environmental sustainability in northern China. The aim of this study was to evaluate a water-saving super-absorbent polymer (SAP) for minimising NO3- leaching from soil and optimising corn growth and yield. Thirty-six undisturbed soil lysimeters were installed in a field lysimeter facility in drought-affected northern China to study the growth and yield characteristics of summer corn (Zea mays L.) as well as the amount of NO3-leaching losses under different fertiliser (standard, medium or 75% and low, or 50% of conventional fertilisation rate) and SAP (control, 0; level-1, 15 kg ha-1 and level-2, 30 kg ha-1) tre...
It has been prepared composites materials by means of monomer penetration in pores of wood samples and later curing by means of gamma irradiation. The studied species were Hura crepitans L. (catahua), Aniba puchury-minor (C. Martinez) (mohena amarilla), and Calycophyllum spruceanum (Benth.) (capirona). These new materials exhibit smaller water absorption and better mechanical properties in comparison with native wood. The test tubes of catahua treated with the styrene-polyester mixture absorb only up to 10% humidity compared to the native species whereas its hardness is increased in a 100%. (author).
The water culture experiment of Houttuynia cordata of the medicinal plant was carried out, and basic study on {sup 137}Cs accumulation characteristic and internal circulation in H. cordata in the fruiting stage was investigated since the flowering season. H. cordata accumulated 80% of {sup 137}Cs absorbed unlike K to the root, rhizome, terminal bud of the underground part for the rhizome reproduction. {sup 137}Cs content to the young leaf, spike, involucre increased in the flowering season. Thereafter, {sup 137}Cs was recirculated to the developing organs in second generations such as the rhizome and bud. (author)
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
The universe is full of exotic particles and waves. Some, such as neutrinos, pass through our neighbourhood unnoticed; others, such as extreme uv radiation, are absorbed by the upper atmosphere before they are able to do too much damage. For a long time, any systematic attempt to understand how our weather can be affected by extra-terrestrial sources other than solar visible and infrared radiation has been a lively and often controversial diversion from mainstream research. But recent scientific and technological breakthroughs and concern over long-term climate change have brought this subject into the spotlight.
This is a preliminary study on the sound absorption properties of two tropical hardwoods, Light Red Meranti and Ramin, and their wood-polymer composites. Sound absorption is measured using a standing wave apparatus. The samples are of one thickness (7 mm) and cut longitudinally. Wood-polymer composites are made by impregnating the samples with methyl methacrylate which is polymerized in situ through #gamma#-irradiation. Both woods and their composites are better sound absorbers at higher sound frequencies. With partial impregnation, the absorption coefficients are improved upon particularly in the region between 1-3 kHz. (author).
The invention concerns a solar power station with a hollow solar heater, which has reflected radiation coming in, focussed by a mirror through the inlet opening. To match the differing solar radiation during the day, the inlet opening can be adjusted by changing its cross-section. This is done by at least two thick flat circular parts which can move relative to each other which are preferably movable relative to each other in pairs on a common rail and which are cooled by a coolant which is the working medium for absorbing solar energy.
In the Aqueous Self-Cooled Blanket (ASCB) concept, an aqueous "6Li solution in a metallic structure is used as a shielding-breeding blanket for fusion reactors. The experimental results of this study indicate that the radiolytic gas production in an ASCB will be proportional to the absorbed radiation energy. The observed radiation chemical yields allow the preliminary estimation of the radiolysis effects for a specific ASCB design. Contrary to the theoretical predictions, the use of hydrogen as a cover gas at up to 1 MPa had no measurable effect on the radiolytic gas production. Probably it will thus not be possible to suppress the radiolytic decomposition of a low-pressure ASCB by the addition of hydrogen. Catalytic recombination will be required. (orig.).
CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.
The study of imported ceramics found in Beirut and suspected to belong to north Syrian products will provide key evidence for the roles in trade of the various postulated centers in northern Syria and northern Lebanon. It is proposed that a comprehensive range of likely north Syrian products imported to Beirut will be chemically analyzed by PIXE (proton induced X-ray emission) in order to characterize, compare and isolate the various regional production centers that supplied the city from the Persian to Byzantine periods. In this work, we were mainly focusing on the characterization of Amrit products, by using 3 MeV proton beam and Al funny filter, as X-ray absorber.
Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.
Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbed dose.
In the prevention of atmospheric pollution by sulfur dioxide emissions from acid absorbers in contact process sulfuric acid plants in which the unconverted SO/sub 2/ is accumulated by adsorption in a zeolite adsorbent bed and desorbed back into the acid production system, it is found that ambient moist air, after partial dehydration in an acid scrubber is suitably used both to cool down and hot purge desorb the zeolite beds. In addition the pure water derived from the ambient air is advantageously used in the acid-making system.
Presented are the results of the investigation of the kinetics and micromechanism of the failure in impact bending of oriented-crystallized specimens having the eutectic composition Ni_3Al-Ni_3Nb and of the bimetal composed of 45 steel + M3 copper. The failure kinetics was studied by high-speed filming, whereas the fractures were studied by electron fractography. The particularities of the failure of the laminar-type composite materials were found. Analyzed was the effect of the kinetic factors and the mechanism of failure upon its energy consumption.
P. Galenko et al. proposed a modified Cahn-Hilliard equation to model rapid spinodal decomposition in non-equilibrium phase separation processes. This equation contains an inertial term which causes the loss of any regularizing effect on the solutions. Here we consider an initial and boundary value problem for this equation in a two-dimensional bounded domain. We prove a number of results related to well-posedness and large time behavior of solutions. In particular, we analyze the existence of bounded absorbing sets in two different phase spaces and, correspondingly, we establish the existence of the global attractor. We also demonstrate the existence of an exponential attractor.
Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.
The author presents a mathematical model for analysis of the impact of scrubber bed length, porosity, and gas flow rate on the absorption of CO{sub 2} in a breathing apparatus. The model accounts for the decrease in available absorbent through chemical conversion. The predicted efflux of CO{sub 2} from a canister containing LiOH compared favorably with measured values reported elsewhere. It was determined from a computational study that the time for breakthrough of CO{sub 2} at a prescribed level is nearly directly proportional to bed length and inversely proportional to gas flow and porosity.
Results of an investigation of the weldability of compact hollow automobile parts are reported. The use of magnetically impelled arc butt (MIAB) welding for a piston rod (OD_22_mm x 2.2_mm thickness), a shock-absorber (OD 40 mm x 2.2 mm) and a torque rod (OD 34 mm x 6 mm) has been investigated. Metallographic examination and comprehensive mechanical testing has been conducted to demonstrate the effectiveness of the method for joining of these types of automobile components
This study presents a theoretical analysis of heat generation and dissipation of field-controllable magneto-rheological fluid (MRF) shock absorbers. Since MRF dampers are energy- dissipating devices, the issues of heat generation and dissipation are important in predicting their performance. A theoretical model is developed based on Bingham plastic model to estimate temperature history of the MRF dampers. The governing equation includes the MRF viscosity as a function of the temperature. The numerical solutions are compared with experimental results in order to validate the accuracy of the model, and excellent agreements are obtained.
The existence of a global attractor for the solution semiflow of the extended Brusselator system in the $L^2$ phase space is proved, which is a cubic-autocatalytic and partially reversible reaction-diffusion system with linear coupling between two compartments. The method of grouping and re-scaling estimation is developed to deal with the challenge in proving the absorbing property and the asymptotic compactness of this typical multi-component reaction-diffusion systems. It is also proved that the global attractor is an $(H, E)$ global attractor with the $L^\\infty$ regularity and that the Hausdorff dimension and the fractal dimension of the global attractor are finite. The results and methodology can find many applications and further extensions in complex biological and biochemical dynamical systems.
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
This study presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing devices, and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitation. It is demonstrated that this fuzzy logic control system can significantly reduce the relative deck displacement using about 60% less power compared to passive on state, while the absolute deck acceleration remains practically unchanged.
This paper describes an exact solution to the problem of absorbing nitrogen dioxide into aqueous solution, in which case the nitrogen dioxide concentration is allowed to vary over a wide range. The authors have worked on the rate of calcium sulfate dihydrate scale formation on the reverse osmosis membrane and find this phenomena can be treated by the crystallization theory. The authors performed long-term experiments using calcium sulfate dihydrate solution with addition of sodium hexametaphosphate (SHMP) and commercially available organophosphates and investigated the mechanism of the inhibitor's action quantitatively.
Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)
In an electromagnetic pump of the present invention for use in circulation of coolants in an LMFBR type reactor, the outer circumference of coil conductors is covered by an insulator retaining cover, and powdery or granular insulator is filled between the coil conductors and the insulator retaining cover. Upon reaching high temperature, elongation of the coil conductors by heat expansion is absorbed by movement of the particles of the powdery insulator thereby preventing excess stresses from exerting on the coil insulator constituted with the insulator retaining cover and the powdery or granular insulator and preventing generation of crackings on the coil insulator. Thus, plant stability is improved. (N.H.).
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
As a counter measure to protect against global warming, the development of CO{sub 2} recovery technology from fossil fuel power plant flue gas has continued. MEA processes are widely used for CO{sub 2} recovery from combustion flue gas in average use etc. However, if we consider power plant scale CO{sub 2} recovery, the biggest theme is the reduction of energy needed to recover CO{sub 2}. The paper focuses on sterically hindered amines and a new absorber packing. Also optimum steam system analysis results are indicated. 1 ref., 16 figs., 3 tabs.
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
Coal slurry pH values can be used to characterize coals. pH values depend on the coal, time since slurry preparation, contact with gas atmosphere, particle size, and stirring. Measured values reflect a sequence of reactions including: carbon dioxide absorption by water from the air, wetting of the coal (pH may be affected by the elemental composition of the mineral matter), and further equilibration with species in the water. The pH initially drops as carbon dioxide is absorbed, then rapidly increases as the coal is wetted, and then slowly decreases as some reactions with species in the water take place.
The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.
An independent chemical compatibility review of various wrapping and absorbent/padding materials was conducted to evaluate resistance to chemicals and constituents present in liquid waste from the Hanford underground tanks. These materials will be used to wrap long-length contaminated equipment when such equipment is removed from the tanks and prepared for transportation and subsequent disposal or storage. The materials studied were Cooley L18KU, Herculite, and Elephant Mat. The study concludes that these materials are appropriate for use in this application.
This handbook breaks down the complex field of nuclear reactor calculations into major steps. Each step presents a detailed analysis of the problems to be solved, the parameters involved, and the elaborate computer programs developed to perform the calculations. This book bridges the gap between nuclear reactor theory and the implementation of that theory, including the problems to be encountered and the level of confidence that should be given to the methods described. Volume III: Control Rods and Burnable Absorber Calculations. Perturbation Theory for Nuclear Reactor Analysis. Thermal Reactors Calculations. Fast Reactor Calculations. Seed-Blanket Reactors. Index.
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO3 promoted by piperazine (PZ). Pilot plant testing was performed in a 16.8-inch ID absorber and stripper with recirculation of air and CO{sub 2}. Three solvents (7 m MEA, 5 m K{sup +}/2.5 m PZ, and 6.4 m K{sup +}/1.6 m PZ) were tested in four campaigns with three different absorber packings. Pilot plant testing established that 5 m K{sup +}/2.5 m PZ requires two times less packing than 7 m MEA and three times less packing than 6.4 m K{sup +}/1.6 m PZ. A rigorous model of the thermodynamics and mass transfer was developed in the RateSep{trademark} block of AspenPlus{reg_sign}. The double matrix stripper reduces energy consumption by 5 to 15%. The best K{sup +}/PZ solvent, 4 m K{sup +}/4 m PZ, and the best process configuration, double matrix stripper with a double intercooled ...
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Progress has been made in this reporting period on three subtasks. A simple thermodynamic model has been developed to represent the CO{sub 2} vapor pressure and speciation of the new solvent. A rate model has been formulated to predict the CO{sub 2} flux with these solutions under absorber conditions. A process and instrumentation diagram and process flow diagram have been prepared for modifications of the existing pilot plant system.
This is an adsorbent for removal of heavy metal impurities from gases. In addition to activated charcoal and ferric chloride, it contains a nonwoven dacron filter material to increase the purification level. The filter material has the following mass % composition: 27-54 activated charcoal, 7-35 ferric chloride, the remainder dacron filter material. The activated charcoal is applied to the dacron filter and the resulting mixture is treated with a ferric chloride solution. The activated charcoal is applied in the form of a suspension with a particle diameter of 0.1-0.16 mm. The treatment solution is 3-20% ferric chloride.
The purpose of the present study is to find ways to reduce the quantity of indoor radon contamination. The study was done from July, 2005 until December, 2005. It was found out that the easiest and most effective way to do that is to open the windows as often as possible and let the indoor air flow outside. When it is not possible to ventilate a room, the indoor radon contamination quantity can reduced by providing activated charcoal in the room. It has been proved that activated charcoal can absorb the room in the air. We need more activated charcoal in proportion to the size of the room. A further research is needed to investigate the amount of activated charcoal that will work most effectively.
This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.
Although some polymer conductors of electricity (ex. Polyanilines) are materials known for more than 100 years, only recently have the interesting chemical, electrical and optic properties of their insulating and conducting forms been recognized. Advances made in the chemistry of polymer conductors have also led to improvements in processing them. This work studies a practical application of these materials: the use of polymer conductors for the remote welding of insulating thermoplastic polymers, using energy from microwaves for the local heating of the union. Many thermoplastics (for ex. Polyethylene) do not absorb, or absorb very little, energy from microwaves. Different conductor materials (conductor polymers, carbon nanotubes), however, heavily absorb energy from microwaves with the resulting heating. In this way the welding zone can be heated without affecting the rest of the piece. Conductor polymers (polyanilines) ...
In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron poisons are converted into ...
In order to demonstrate possible specific effects of microwaves at the cellular level V-79 Chinese hamster cells were exposed to 2.45-GHz radiation at power levels of 20-200 mW/cm2 and at specific absorption rates of 10-100 mW/g. Intracellular cytoplasmic changes were observed by fluorescence polarization using a method based on the intracellular enzymatic hydrolysis of nonfluorescent fluorescein diacetate (FDA). At levels of absorbed energy below 90 J/g, modifications of microviscosity and mitochondrial state were absent, but a slight stimulation of enzymatic hydrolysis of FDA was observed which may be explained by microwave-induced alterations of cellular membranes possibly due to differences in heating pattern of microwaves compared to water-bath heating. At levels of absorbed energy above 90 J/g, the decrease of enzymatic hydrolysis of FDA, increase in degree of polarization, and increase of permeation of the fluorescent marker correlated ...
As a result of the large limestone deposits available in Poland, the low cost of reagent acquisition for the largescale technological use and relatively well-documented processes of flue gas desulfurization (FGD) technologies based on limestone sorbent slurry, wet scrubbing desulfurization is a method of choice in Poland for flue gas treatment in energy production facilities, including power plants and industrial systems. The efficiency of FGD using the above method depends on several technological and kinetic parameters, particularly on the pH value of the sorbent (i.e., ground limestone suspended in water). Consequently, many studies in Poland and abroad address the impact of various parameters on the pH value of the sorbent suspension, such as the average diameter of sorbent particles (related to the limestone pulverization degree), sorbent quality (in terms of pure calcium carbonate [CaCO3] content of the sorbent material), stoichiometric surfeit of CaCO3 in relation to sulfur ...
Spectral room temperature photoluminescence (pl) of polycrystalline Cu(In,Ga)Se2 films (CIGSe) is evaluated with respect to optoelectronic properties and in particular for the determination of the splitting of quasi-Fermi levels (EFn - EFp). For lateral resolution of ? 1 ?m a confocal pl-setup is used. The depth profile of the excess carrier densities determining the rates of radiative transitions strongly govern the spectral pl-shape which has been numerically modeled with a matrix transfer formalism. In this optical approach we discriminate for wave propagation and attenuation in a multilayer system between a plane-wave ansatz and a 3D-spherical formalism, depending on excitation area large or small/similar compared to the thickness of the absorber. In both cases re-absorption of photons in energetic regimes with absorption approaches unity, from which the splitting of the quasi-Fermi levels is preferentially deduced, substantially influence the spectral ...
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% for the worst-case ...
Aqueous solutions of 2-amino-2-hydroxymethyl-1,3-propanediol (AHPD), a sterically hindered amine, was examined as a potential CO{sub 2} absorbent and compared with the most commonly used absorbent, monoethanolamine (MEA) solution, through equilibrium solubility measurements and {sup 13}C NMR spectroscopic analyses. The solubilities of CO{sub 2} in aqueous 10 mass % AHPD solutions were higher than those in aqueous 10 mass% MEA solutions above 4 kPa at 298.15 K, but lower below 4 kPa. The solubility difference between these two solutions increased with the CO{sub 2} partial pressures above the crossover pressure. Equilibrated CO{sub 2}-MEA-H{sub 2}O and CO{sub 2}-AHPD-H{sub 2} solutions at various CO{sub 2} partial pressures ranging from 0.01 to 3000 kPa were analyzed by {sup 13}C NMR spectroscopy. AHPD contains more hydroxyl groups than nonhindered MEA, and hence the chemical shifts in its {sup 13}C NMR spectra were strongly influenced by the ...
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such that the results are ...
Thermoplastic polymer materials and the compounds made with them are being used more frequently for industrial components and for general use. However, the application of these materials for the production of complex shaped or relatively large pieces is limited, because of the difficulty and cost of making the necessary tool kit for the job. One solution is the use of the welding process. But the safe and reliable union of different thermoplastic material parts is not a simple process, even less so in the case of unions of large components. Welding by microwaves using polymer conductors can help, since the large scale equipment is available, and methods for continuous processes by microwave have been developed, that can be used to weld large and small components. Many thermoplastics (ex. polyethylene) do not absorb, or absorb very little, energy from microwaves. Polymer conductors, however, heavily absorb from microwaves ...
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
Remote detection of chemicals using LIDAR (Light Detection and Ranging) utilizing DIAL (Differential Absorption LIDAR) is now a standard detection technique for both military and civilian activities. We have developed a novel nonlinear optical phase conjugation system that can reduce the effects of speckle noise and atmospheric turbulence on DIAL remote detection systems. We have shown numerically and experimentally that it is possible to increase the signal-to-noise (S/N) ratio for LIDAR systems under certain conditions using optical phase conjugation. This increase in S/N can result in more accurate detection of chemical effluents while simultaneously reducing the time necessary to acquire this information.
We investigated the presence of XMRV in a cohort of Quebec patients with chronic fatigue syndrome (CFS). DNA was purified from activated peripheral blood mononuclear cells (PBMCs) and PCR was used to detect XMRV gag and env in 72 patients. Anti-XMRV antibodies were searched in sera of 62 patients by Western blot analysis. Attempts to detect XMRV antigens was made, using immunofluorescence with Gag anti-p30 antiserum on activated PBMC from 50 patients. Plasma viremia was measured by RT-PCR on 9 subjects. Finally, detection of infectious virus in 113 CFS subjects was made by co-culture of PHA+IL-2 activated PBMC with human LNCaP carcinoma cells, and by infecting the same susceptible cells with plasma, using a reverse transcriptase (RT) assay as a readout in both experiments. No detection of ...
Speech perception integrates auditory and visual information. This is evidenced by the McGurk illusion where seeing the talking face influences the auditory phonetic percept and by the audiovisual detection advantage where seeing the talking face influences the detectability of the acoustic speech signal. Here, we show that identification of phonetic content and detection can be dissociated as speech-specific and non-specific audiovisual integration effects. To this end, we employed synthetically modified stimuli, sine wave speech (SWS), which is an impoverished speech signal that only observers informed of its speech-like nature recognize as speech. While the McGurk illusion only occurred for informed observers, the audiovisual detection advantage occurred for na?ve observers as well. Thi...
A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures ...
Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.
A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence ...
Embedded systems have become integral parts of a diverse range of systems from automobiles to critical infrastructure applications such as gas and electric power distribution. Unfortunately, research on computer security in general and intrusion detection in particular, has not kept pace. Furthermore, embedded systems, by their very nature, are application specific and therefore frameworks for developing application-specific intrusion detection systems for distributed embedded systems must be researched, designed, and implemented. In this paper, we present a configurable middleware-based intrusion detection framework. In particular, this paper presents a system model and a concrete implementation of a highly configurable intrusion detection framework that is integrated into MicroQoSCORBA, a highly configurable middleware framework developed for embedded systems. By exploiting the application-specific ...
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) and ...
Ultraviolet (UV) photoirradiation of Ag(I) compounds in the presence of an aqueous Triton X-100 solution has been exploited for the first time to prepare reproducible yellow silver hydrosol. The evolution of nanosized silver particles has been examined critically under the influence of different anions/ligands. Hence, time dependent evolution of silver hydrosol from different silver compounds in micelle via photochemical reduction is observed. Anions/ligands of precursor salts have been found to show profound influence (due to electron scavenging property, solubility, stability etc.) on the evolution route and efficiency of photochemical reduction of Ag(I) to Ag(O) in micelle and thereby classification of silver compounds becomes possible. Kinetic results reveal that the formation of silver particles proceeds via autocatalytic growth mechanism. The observed variation in rate constant values for the evolution of nanoparticles from different silver compounds have ...
Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers adjacent tothe substrateremained intact even ...
In models with dynamical electroweak symmetry breaking, this breaking is normally communicated to quarks and leptons by a set of vector bosons with masses generated via sequential breaking of a larger gauge symmetry. In reasonably ultraviolet-complete theories of this type, the number of stages of breaking of the larger gauge symmetry is usually equal to the observed number of quark and lepton generations, $N_{gen.}=3$. Here we investigate the general question of how the construction and properties of these models depend on $N_{gen.}$, regarded as a variable. We build and analyze models with illustrative values of $N_{gen.}$ different from 3 (namely, $N_{gen.}=1,2,4$) that exhibit the necessary sequential symmetry breaking down to a strongly coupled sector that dynamically breaks electroweak symmetry. Our results for variable $N_{gen.}$ show that one can robustly obtain, for this latter sector, a theory with a gauge coupling that is large but slowly running, ...