WorldWideScience
 
 
1

Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea  

UK PubMed Central (United Kingdom)

Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available

2009-06-01

2

Simulation-based training improves applied clinical placement of ultrasound-guided PICCs  

British Library Electronic Table of Contents (United Kingdom)

Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...

2011-01-01

3

Ultrasound-Guided Three-In-One Nerve Block for Femur Fractures  

UK PubMed Central (United Kingdom)

Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available

2010-09-01

4

Efficacy of ultrasound-guided obturator nerve block in transurethral surgery  

UK PubMed Central (United Kingdom)

Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available

2011-01-01

6

Hepatosplenic T-cell lymphoma is a distinct rare entity: Diagnosis by fine-needle aspiration cytology  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.

2011-01-01

7

Percutaneous endoscopic lumbar discectomy: clinical and quality of life outcomes with a minimum 2 year follow-up  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic lumbar discectomy is a relatively new technique. Very few studies have reported the clinical outcome of percutaneous endoscopic discectomy in terms...Full Text Available

8

Percutaneous duodenostomy - alternative route for enteral nutrition  

International Nuclear Information System (INIS)

Percutaneous translumbar duodenostomy for enteral feeding was performed in one patient with nutritional difficulties. No complication was encountered. The procedure can be an alternative to percutaneous gastrostomy and jejunostomy for enteral feeding in special situations. (orig.).

9

Four Cases of a Cerebral Air Embolism Complicating a Percutaneous Transthoracic Needle Biopsy  

UK PubMed Central (United Kingdom)

A percutaneous transthoracic needle biopsy is a common procedure in the practice of pulmonology. An air embolism is a rare but potentially fatal complication of a percutaneous transthoracic needle biopsy....Full Text Available

2009-01-01

10

Percutaneous tracheostomy  

UK PubMed Central (United Kingdom)

Background:Percutaneous tracheostomy (PT) has gained an increasing acceptance as an alternative to the conventional surgical tracheostomy (ST). In experienced hands, and with...Full Text Available

1999-01-01

11

Percutaneous renal biopsy as an outpatient procedure.  

UK PubMed Central (United Kingdom)

Percutaneous renal biopsy (PRB) is a safe and effective tool in the diagnosis and management of renal disease. It is the gold standard for evaluating renal parenchymal disease. It is both useful for...Full Text Available

2004-09-01

12

Close to Transplant Renal Artery Stenosis and Percutaneous Transluminal Treatment  

UK PubMed Central (United Kingdom)

Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS)....Full Text Available

2011-01-01

13

CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections  

International Nuclear Information System (INIS)

The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.

1999-03-01

15

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

16

Treatment of large lumbar disc herniation with percutaneous ozone injection via the posterior-lateral route and inner margin of the facet joint  

UK PubMed Central (United Kingdom)

AIM: To evaluate the effects of percutaneous ozone injection via the posterior-lateral route and inner margin of the facet joint in the treatment of large lumbar disc herniation.METHODS:...Full Text Available

2010-03-28

17

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

18

Revisional Percutaneous Full Endoscopic Disc Surgery for Recurrent Herniation of Previous Open Lumbar Discectomy  

UK PubMed Central (United Kingdom)

Study DesignA retrospective study.PurposeTo determine the feasibility and effectiveness of revisional percutaneous full endoscopic discectomy for...Full Text Available

2011-03-01

19

Retrosternal Percutaneous Tracheostomy: An Approach for Predictably Impossible Classic Tracheostomy  

UK PubMed Central (United Kingdom)

Percutaneous tracheostomy is a routine procedure in intensive care units. In cases of very low position of the larynx, cervical spine deformation, morbid obesity, or neck tumor, performance of the classic...Full Text Available

2010-01-01

20

Pyogenic Spondylodiscitis after Percutaneous Endoscopic Lumbar Discectomy  

UK PubMed Central (United Kingdom)

We reviewed 9 cases of pyogenic spondylodiscitis following percutaneous endoscopic lumbar discectomy (PELD). Microbiologic cultures revealed 6 causative organisms. Five patients were managed conservatively...Full Text Available

2010-11-01

 
 
 
 
21

Pharmacological Prevention of Peri-, and Post-Procedural Myocardial Injury in Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

In recent years, percutaneous coronary intervention (PCI) has become a well-established technique for the treatment of coronary artery disease. PCI improves symptoms in patients with coronary artery...Full Text Available

2008-08-01

22

Percutaneous mitral valve repair: the beginning of the end or the end of the beginning?  

UK PubMed Central (United Kingdom)

The new percutaneous mitral valve repair techniques are at an early stage. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary...Full Text Available

23

Percutaneous endoscopic lumbar discectomy for migrated disc herniation: classification of disc migration and surgical approaches  

UK PubMed Central (United Kingdom)

Percutaneous endoscopic lumbar discectomy (PELD) for migrated disc herniations is technically demanding due to the absence of the technical guideline. The purposes of this study were to propose a radiologic...Full Text Available

2007-03-01

24

Percutaneous core excision and radiofrequency thermo-coagulation for the ablation of osteoid osteoma of the spine  

UK PubMed Central (United Kingdom)

Percutaneous radiofrequency ablation is the treatment of choice for osteoid osteoma of the appendicular skeleton. However, difficulties in localizing the lesion in the spine and its proximity to neural...Full Text Available

2009-03-01

25

Percutaneous absorption of aromatic amines in rubber industry workers: impact of impaired skin and skin barrier creams  

UK PubMed Central (United Kingdom)

BackgroundSeveral aromatic amines (AA) could cause bladder cancer and are an occupational hygiene problem in the workplace. However, little is known about the percutaneous absorption...Full Text Available

2007-06-01

26

Percutaneous Management of a Long Saphenous Vein Graft Aneurysm: A Case Report and Review of Literature  

UK PubMed Central (United Kingdom)

Aneurysms of saphenous vein grafts are rare but can result in complications such as myocardial infarction or death. Percutaneous treatment has included a variety of approaches, including covered stents....Full Text Available

2009-01-01

27

Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve  

UK PubMed Central (United Kingdom)

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available

2010-06-28

28

Outpatient percutaneous coronary intervention: Ready for prime time?  

UK PubMed Central (United Kingdom)

Outpatient practice after percutaneous coronary intervention (PCI) is gaining momentum due to constantly optimizing results. Furthermore, the availability of limited beds to handle the large volume...Full Text Available

2007-10-01

29

Endovascular covered stenting for the management of post-percutaneous nephrolithotomy renal pseudoaneurysm: a case report  

UK PubMed Central (United Kingdom)

IntroductionIntrarenal pseudoaneurysm is a rare, yet clinically significant, complication of percutaneous nephrolithotomy. A high index of clinical suspicion is necessary in order...Full Text Available

30

Echocardiographic assessment and percutaneous closure of multiple atrial septal defects  

UK PubMed Central (United Kingdom)

Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is...Full Text Available

31

Comparison of prasugrel and clopidogrel in patients with acute coronary syndrome undergoing percutaneous coronary intervention  

UK PubMed Central (United Kingdom)

Antiplatelet agents are the cornerstone of treatment for patients with acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI). Clopidogrel, when added to aspirin, has demonstrated...Full Text Available

2009-01-01

32

Comparison of Percutaneous Endoscopic Lumbar Discectomy and Open Lumbar Microdiscectomy for Recurrent Disc Herniation  

UK PubMed Central (United Kingdom)

ObjectiveThe purpose of this study was to compare clinical and radiological outcomes of percutaneous endoscopic lumbar discectomy (PELD) and open lumbar microdiscectomy (OLM) for...Full Text Available

2009-12-01

34

Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...

2003-06-01

35

Endobronchial ultrasound with transbronchial needle aspiration for restaging the mediastinum in lung cancer  

DEFF Research Database (Denmark)

Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...

2008-01-01

36

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

37

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

38

Late Life-Threatening Hemorrhage after Percutaneous Tracheostomy  

UK PubMed Central (United Kingdom)

Purpose. Formation of a tracheoinnominate artery fistula (TIF) and consecutive hemorrhage is a rare and life-threatening complication with high mortality. Warning symptoms can...Full Text Available

2011-01-01

39

Cryoanalgesia for intractable perineal pain.  

UK PubMed Central (United Kingdom)

Cryoanalgesia, the local application of extreme cold to nerves to produce analgesia, has been used to treat patients with intractable perineal pain. The cryoprobe was inserted percutaneously through...Full Text Available

1981-11-01

40

The Risk of Paradoxical Embolism (RoPE) Study: Developing risk models for application to ongoing randomized trials of percutaneous patent foramen ovale closure for cryptogenic stroke  

UK PubMed Central (United Kingdom)

BackgroundDespite the diffusion into practice of percutaneous closure of a patent foramen ovale (PFO) in patients with cryptogenic stroke (CS), the benefits have not been demonstrated,...Full Text Available

 
 
 
 
41

Huge Psoas Muscle Hematoma due to Lumbar Segmental Vessel Injury Following Percutaneous Endoscopic Lumbar Discectomy  

UK PubMed Central (United Kingdom)

We present a case of an acute psoas muscle hematoma following percutaneous endoscopic lumbar discectomy. A 60-year-old female who presented with far lateral lumbar disc herniation underwent endoscopic...Full Text Available

2009-03-01

42

Percutaneous drainage of abdominal abcess  

Energy Technology Data Exchange (ETDEWEB)

The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. ...

2002-09-01

43

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis ...

2001-03-01

44

Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride  

Energy Technology Data Exchange (ETDEWEB)

The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

2009-10-15

45

Percutaneous nephrolithotomy for staghorn kidney stones in elderly patients  

British Library Electronic Table of Contents (United Kingdom)

Purpose We retrospectively analyzed the results of percutaneous nephrolithotomy operations for treatment of staghorn kidney stone disease in elderly patients and compared surgical parameters and outcomes with a control group of young adult patients. Patients and method Between 2002 and 2010, 300 consecutive patients underwent percutaneous nephrolithotomy operation for treatment of staghorn kidney stone disease. Forty-five of the patients were older than 65?years and considered to be in elderly group. Thirty-seven of the patients were between the ages 18 and 36?years and considered to be the control group. Surgical parameters and outcomes were compared between groups. Results There were no significant differences between groups for stone area, operation time, difference in hemoglobin levels...

2011-01-01

46

Usefulness of thromboaspiration with Desilets-Hoffman sheath in thrombosed hemodialysis access graft  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a Desilets-Hoffman Sheath compared with the previously established percutaneous mechanical thrombectomy technique in cases of occluded dialysis graft. One hundred and sixty eight patients (103 women, 65 men; mean age, 54.7 years; mean graft age, 20.9 months) with 225 episodes of dialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using the crossing catheter or single puncture technique. The technical success rate, procedure time, and complication and patency rates were analyzed. Technical success was achieved in 200 of the 225 procedures (88.9%). The average duration of the intervention was 74.3 {+-} 35 minutes. The primary patency rate was 63.1% at 3 months, 44.2% at 6 months and 26.3% at 1 year. Major complications occurred in 4% of the cases (4 venous ...

2004-07-01

47

Use of clopidogrel in the reduction of myocardial damage during percutaneous coronary intervention  

UK PubMed Central (United Kingdom)

It is estimated that approximately a quarter of patients undergoing coronary intervention may have significant post-procedural creatinine (CK)/creatinine kinase myocardial band (CK-MB) elevations and...Full Text Available

2009-01-01

48

Primary hemifacial spasm: a neurophysiological study.  

UK PubMed Central (United Kingdom)

A series of 53 cases of primary hemifacial spasm have been evaluated by means of blink reflexes and their results compared with a normal control group. Reflex responses were obtained by percutaneous...Full Text Available

1986-01-01

49

Obstructive Jaundice after Bilioenteric Anastomosis: Transhepatic and Direct Percutaneous Enteral Stent Insertion for Afferent Loop Occlusion  

UK PubMed Central (United Kingdom)

Recurrent tumour after radical pancreaticoduodenectomy may cause obstruction of the small bowel loop draining the liver. Roux-loop obstruction presents a particular therapeutic challenge, since the...Full Text Available

2010-09-01

50

New methods of making blocked coronary arteries patent again.  

UK PubMed Central (United Kingdom)

The use of percutaneous transluminal coronary angioplasty is limited by procedural complications and the serious drawback of restenosis, but some new techniques have been developed in an attempt to...Full Text Available

1994-09-03

51

Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine  

UK PubMed Central (United Kingdom)

BackgroundObservational clinical studies have shown that patients with diabetes have less favorable results after percutaneous coronary intervention compared with the non-diabetic...Full Text Available

52

Left Main Coronary Stenosis as a Consequence of Bentall Operation: Percutaneous Treatment  

UK PubMed Central (United Kingdom)

A 65-year-old man suffering from ascending aorta aneurysm and atherosclerotic three vessel disease without left main involvement underwent aortic root replacement with coronary ostia reimplantation...Full Text Available

2009-01-01

53

Intravascular ultrasound to guide the management of intracoronary thrombus: a Case Report  

UK PubMed Central (United Kingdom)

Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available

54

Health-related quality of life following percutaneous coronary intervention: the impact of age on outcome at 1 year.  

Science.gov (United States)

This study was performed to assess the possibility that patient age may independently affect improvements in health-related quality of life following percutaneous coronary intervention. One hundred five patients undergoing elective percutaneous coronary intervention at a single tertiary referral center between January 10, 2001 and January 6, 2002 were enrolled and prospectively evaluated. Health-related quality of life was assessed before and 1 year following percutaneous coronary intervention using Short Form-12 and the Seattle Angina Questionnaire. For the purpose of analysis, patients were divided according to age (younger than 60, 60-70, and older than 70 years). One hundred patients (95%) completed both questionnaires. Baseline characteristics among the age groups were similar in terms of gender, cardiac risk factors, and procedural details. All health-related quality-of-life indices demonstrated improvements with at ...

55

Drug-Eluting Stents versus Bare Metal Stents in Unprotected Left Main Coronary Artery Stenosis: a Meta-Analysis  

UK PubMed Central (United Kingdom)

ObjectivesWe undertook a meta-analysis to assess outcomes for drug-eluting (DES) and bare metal stents (BMS) in percutaneous coronary intervention (PCI) for unprotected...Full Text Available

2010-06-01

56

Cangrelor increases the magnitude of platelet inhibition and reduces interindividual variability in clopidogrel-pretreated subjects  

UK PubMed Central (United Kingdom)

BackgroundInadequate platelet inhibition despite aspirin and clopidogrel therapy during and after a percutaneous coronary intervention is associated with an impaired clinical outcome....Full Text Available

2009-05-01

57

Abciximab: a reappraisal of its use in coronary care  

UK PubMed Central (United Kingdom)

Platelet reactivity plays a pivotal role in the pathogenesis of ischemic adverse events during and after acute coronary syndromes (ACS), and percutaneous coronary intervention (PCI). Glycoprotein (GP)...Full Text Available

2008-03-01

58

The application of 64 multidetector CT angiography in the evaluation of carotid stenosis and follow-up of carotid endarterectomy and percutaneous transluminal stenting  

International Nuclear Information System (INIS)

Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the ...

2006-09-01

59

The use of SMARTeR stents in patients with biliary obstruction  

Energy Technology Data Exchange (ETDEWEB)

AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.

2004-03-01

60

Percutaneous mechanical declotting of thrombosed dialysis graft  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the effectiveness of percutaneous mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Technical success was achieved in 24 of 32 cases, with a procedure time of 30-240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pulmonary embolism. The six-month patency rate was 67.8%. Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpensive, safe and fast, and is well tolerated. (author)

2000-10-01

 
 
 
 
61

Intestinal Ischemia for estenosis of the superior mesenteric artery, Treatment with angioplastia and stent implant  

International Nuclear Information System (INIS)

Chronic mesenteric arterial ischemia is an uncommon condition associated a high morbidity and mortality. It is most Commonly caused by atherosclerotic occlusive disease. Patients may suffer epigastric or periumbilical postprandial pain ten to thirty minutes after eating. A case of chronic mesenteric artery stenosis, the diagnosis was performance with colonoscopy and biopsy. We present a case report of a patient with chronic mesenteric ischemia. Mesenteric arteriography was performed and documented estenosis of the mesenteric superior artery. Then percutaneous arteriography with angioplasty and implant of stent was performed. The patients became completely asymptomatic and normal colon mucous is observed in control colonoscopy. The purpose of this report is to present the case endoscopy, clinic and radiological features and to describe the percutaneous angioplasty and implant of stent. We believe that angioplasty treatment offers and improvement ...

62

Integrated Coronary Physiology in Percutaneous Intervention: A new paradigm in interventional cardiology  

British Library Electronic Table of Contents (United Kingdom)

Coronary angiography has provided an unrivalled appreciation of coronary anatomy fostering a far greater appreciation of the extent of atherosclerotic disease. However, the subjectivity of coronary angiography at determining the extent of plaque has been exposed with IVUS. Indices of coronary physiology have provided valuable adjunctive information as to the physiological importance of specific lesions. Fractional flow reserve is an established method for evaluating the significance of epicardial stenoses. Fractional flow reserve guided percutaneous coronary intervention is associated with improved outcomes when compared to a conventional angiographic guided strategy, particularly in intermediate lesions. The use of coronary physiology in the cath lab represents a new avenue to guide appro...

2011-01-01

63

Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases  

British Library Electronic Table of Contents (United Kingdom)

Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...

2008-01-01

64

Use of platelet glycoprotein IIb/IIIa inhibitors in diabetics undergoing PCI for non-ST-segment elevation acute coronary syndromes: impact of clinical status and procedural characteristics  

UK PubMed Central (United Kingdom)

BackgroundThe most recent ESC guidelines for percutaneous coronary intervention (PCI) recommend the use of glycoprotein IIb/IIIa inhibitors (GPI) in high risk patients with non-ST-segment...Full Text Available

2010-06-01

65

Transesophageal echo to help percutaneous closure of ventricular septal defect post acute myocardial infarction  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.

2011-01-01

66

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

67

Percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency: efficacy of mechanical thrombectomy with using the stone basket  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the procedural success after percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency and the efficacy of performing mechanical thrombectomy with using the stone basket. From March 2004 to June 2005, 36 thrombosed native hemodialysis access shunts in the upper limbs (brachiocephalic fistulas: 16 and radiocephalic fistulas: 20) were percutaneously treated in 30 patients. Declotting procedures were performed with using urokinase (100,00-200,000 unit) and manual catheter-directed thrombo-aspiration in all the patients. Angioplasty (6 mm in diameter and 4 cm in length) was performed at the identified area of the stenosis and /or with maceration of the thrombus. In 14 cases with massive thrombosis that was refractory to the above mentioned declotting procedures, mechanical thrombectomy with using a Wittich nitinol stone basket (Cook, Bloomington, IN) was performed. Data regarding the procedural ...

2006-06-15

68

Percutaneous intervention in the menagement of insufficient native arteriovenous hemodialysis fistulae  

Energy Technology Data Exchange (ETDEWEB)

To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), artery (n=6), and at the site of anastomosis ...

2002-11-01

69

A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program  

UK PubMed Central (United Kingdom)

BackgroundPaclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation...Full Text Available

70

Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow ...

2001-11-01

71

The interventional treatment for biliary re-stenosis after metallic stents placement in patients with malignant obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional treatment for biliary re-stenosis after metallic stents placement in patients due to cholangiocarcinoma and evaluate its therapeutic effect. Methods: Percutaneous metallic stents placement or combined with continuously infusion arterial chemotherapeutic and chemotherapeutic embolization were performed in 12 patients with biliary re-stenosis using 12 metallic stents. Results: Once stent placement was 100% successful in all 12 cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that in preoperation. Jaundice was reduced satisfactorily in 12 patients. 3 patients were undergone continuously arterial chemotherapeutics infusion and chemotherapeutic embolization 4 weeks after stents placement. Conclusions: Percutaneous replacement of biliary metallic stents was effective and safe for palliation of malignant biliary re-stenosis and would be much better when combined with ...

2002-10-01

72

Lipiodol-CT in the detection of tumor persistence in hepatocellular carcinoma treated with percutaneous ethanol injection  

Energy Technology Data Exchange (ETDEWEB)

Our purpose was to investigate the usefulness of Lipiodol-CT for detection of residual viable neoplastic tissue in hepatocellular carcinoma (HCC) lesions treated by means of percutaneous ethanol injection (PEI). An emulsion of 5 to 20 ml iodized oil and 50 to 70 mg doxorubicin hydrochloride was intraarterially injected in 18 patients with 25 HCC lesions treated by means of PEI one to 24 months before. At CT performed 3 to 5 weeks after injection, retention of Lipiodol was observed in 9 of 13 tumors that still contained viable neoplastic tissue and in 2 of 12 tumors proven to have undergone complete necrosis after PEI. The sensitivity and specificity of Lipiodol-CT were 69.2% and 83.3%, respectively. Thus, Lipiodol-CT seems to have limited diagnostic value after PEI, probably as a consequence of the alcohol-induced vascular damage, accounting for both false-negative and false-positive results. (orig.).

1994-07-01

73

Health Related Quality of Life After Percutaneous Coronary Revascularisation in Patients with Previous Coronary Artery Bypass Grafts: A Two-Year Follow Up Study  

British Library Electronic Table of Contents (United Kingdom)

Percutaneous coronary revascularisation [PCR] improves angina and health related quality of life [HRQOL] compared to standard medical therapy. It is unknown whether PCR has the same benefits for patients with a history of CABG. Over a period of 5?years, we assessed HRQOL of patients undergoing PCR using Part 1 of the Nottingham Health Profile [NHP] at baseline 3, 12 and 24?months. We compared HRQOL after PCR in 255 patients with CABG to 2680 without. There were more males [81.1% v 69.6% p?=?0.002] and older patients [mean age 60.1?years v. 58.0 p?=?0.03] in CABG group. Perceived HRQOL improved at 24?months for pain, energy and emotional reaction but the improvement was less in the CABG group. However, mean NHP scores at 24?months for those with CABG had returned to baseline levels for slee...

2011-01-01

74

Effect of percutaneous transluminal angioplasty in insufficiency of arteriovenous fistula for hemodialysis  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the effectiveness of percutaneous transluminal angioplasty(PTA) and to determine the factors affecting the long-term patency rate in the management of insufficient hemodialytic arteriovenous fistula(AVF). Forty-nine cases of insufficient hemodialytic AVF were treated in 44 patients(native AVF:20, graft AVF:29, M:17, F:27, Age:22-70 years). In 28 thrombus patients, thrombolysis was performed with urokinase, and was followed by PTA. The initial success rate and complications of PTA were evaluated. According to the site and length of the stenosis, type and age of the AVF, the presence or abscence of thrombus, a history of diabetic mellitus, the patient's age, and the duration of renal failure, patency rates were compared within each subgroup using the Kaplan-Meier logrank test. The initial success rate of PTA for insufficient hemodialytic AVF was 88%(43/49), the patency rate of PTA was 67% at 6 months, and 50% at 12 months. The initial success ...

1999-06-01

75

CT diagnosis of subphrenic abscess after splenectomy for trauma; Ruolo della tomografia computerizzata nella valutazione degli ascessi subfrenici dopo splenectomia post-traumatica  

Energy Technology Data Exchange (ETDEWEB)

The paper studies subphrenic inflammatory abscesses and splenic fluid collections after splenectomy for trauma. These complications may appear early or late postoperatively; they are easily demonstrated with computerized tomography, which permits accurate spatial assessment of the lesions and appropriate treatment with percutaneous drainage. It has been also investigates the diagnostic accuracy of the CT in subphrenic inflammatory conditions after emergency splenectomy for traumatic spleen rupture and found that CT is a precious tool for rapid and easy diagnosis and follow-up of subphrenic abscesses treated with percutaneous drainage. [Italian] Scopo del lavoro e' di valutare il ruolo della tomografia computerizzata nelle flogrosi subfreniche secondarie a splenectomia d'urgenza per rottura traumatica della milza, documentando come tale metodica risulti accurata nel diagnosticare e monitorare in modo semplice e rapido ...

1999-09-01

76

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

77

Percutaneous US-guided RF thermal ablation for malignant renal tumors: preliminary results in 13 patients  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive treatment for small renal cell carcinoma (RCC) can be necessary in selected patients and, anyway, is desirable. In situ ablation techniques, including RFA, have been developed. The aim of this study is to evaluate the feasibility, safety and short-term local effectiveness of percutaneous US-guided RFA in a small series, as well as mid-term patient outcome. Thirteen patients with a total of 18 tumors (17 small lesions, 35 mm in size or less, and a larger one, 75 mm in size) underwent 19 RFA sessions. Seven patients had a solitary kidney, and three suffered from VHL disease, too. We treated four lesions in a patient with a bilateral tumor. In another patient, three lesions were ablated. Seventeen tumors were RCC; one was a metastasis from lung cancer. Eight lesions were parenchymal, six exophytic, two parenchymal/exophytic, one parenchymal/central and one central. A monopolar RF system with multitined expandable electrode needles was used. The ...

2004-12-01

78

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures  

International Nuclear Information System (INIS)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...

1999-12-01

79

Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent  

Energy Technology Data Exchange (ETDEWEB)

To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in ...

2002-07-01

80

Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two ...

2010-08-01

 
 
 
 
81

Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model.  

Science.gov (United States)

Percutaneous osseointegrated prostheses are being investigated as an alternative strategy to attach prosthetic limbs to patients. Although the use of these implants has shown to be promising in clinical trials, the ability to maintain a skin seal around an osseointegrated implant interface is a major challenge to prevent superficial and deep periprosthetic infections. The specific aim of this study was to establish a translational load-bearing ovine model to assess postoperative limb compensation and gait symmetry following a percutaneous osseointegrated implant. We tested the following hypotheses: (1) the animals would return to pre-amputation limb loads within 12-months; (2) the animals would return to a symmetrical gait pattern (stride length and time in stance) within 12-months. The results demonstrated that one month following surgery, the sheep loaded their amputated limb to a mean value of nearly 80% of their pre-amputation loading ...

2011-09-13

82

Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 ...

2007-10-01

83

[Pulmonary vascular manifestations in hereditary hemorrhagic telangiectasia].  

Science.gov (United States)

Hereditary hemorrhagic telangiectasia (Osler-Rendu-Weber disease) is a genetic disorder with autosomal dominance, variable penetrance, and an estimated prevalence of 1/10,000 inhabitants in France. Diagnosis is based on clinical criteria including epistaxis, telangiectasia, visceral manifestations, and familial occurrence. Pulmonary arteriovenous malformations, present in 15-33% of patients, are its primary visceral complications. The disease may be revealed by infectious and ischemic neurological manifestations due to paradoxical embolism. The high frequency of neurologic complications even in asymptomatic patients justifies systematic screening for pulmonary arteriovenous malformations. Treatment of these malformations is based on percutaneous transcatheter coil embolization of the feeding artery. Pulmonary arterial hypertension is rare in this disease. It may be due to systemic arteriovenous shunting in the liver, which increases cardiac output, or be similar to ...

2005-11-01

84

Venous Thoracic Outlet Compression and the Paget-Schroetter Syndrome: A Review and Recommendations for Management  

British Library Electronic Table of Contents (United Kingdom)

Paget Schroetter syndrome, or effort thrombosis of the axillosubclavian venous system, is distinct from other forms of upper limb deep vein thrombosis. It occurs in younger patients and often is secondary to competitive sport, music, or strenuous occupation. If untreated, there is a higher incidence of disabling venous hypertension than was previously appreciated. Anticoagulation alone or in combination with thrombolysis leads to a high rate of rethrombosis. We have established a multidisciplinary protocol over 15?years, based on careful patient selection and a combination of lysis, decompressive surgery, and postoperative percutaneous venoplasty. During the past 10?years, a total of 232 decompression procedures have been performed. This article reviews the literature and presents the Exet...

2011-01-01

85

Treatment of hilar cholangiocarcinoma with inserting biliary double stents  

International Nuclear Information System (INIS)

Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 #+-# 29) #mu#mol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

2004-10-01

86

The interventional treatment for biliary recurrent obstruction after palliative T tube drainage in patients with obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice

2002-10-01

87

Clinical Evaluation of the Zilver Vascular Stent for Symptomatic Iliac Artery Disease  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate the safety and effectiveness of the Zilver vascular stent in the treatment of de novo or restenotic lesions in the external and common iliac arteries.Materials and MethodsRegardless of the results of an initial percutaneous transluminal angioplasty (PTA), 151 consecutive patients were implanted with Zilver vascular stents (Cook, Bloomington, Ind) in up to two stenotic (?10 cm) or occluded (?5 cm) atherosclerotic lesions of the external or common iliac arteries. The primary endpoint was the rate of major adverse events within 9 months after the procedure. Major adverse events were defined as death, myocardial infarction, target lesion revascularization, and limb loss. Secondary endpoints included acute procedural success, 30-day clinical success, 9-month pat...

2008-01-01

88

Chemoradiotherapy of unresectable and recurrent cholangiocarcinoma  

International Nuclear Information System (INIS)

This study is for chemoradiotherapy of unresectable and recurrent cholangiocarcinoma (CCC). Between April 2005 and March 2007, 5 patients were evaluated for unresectable and recurrent CCC. All patients were performed percutaneous transhepatic biliary drainage (PTBD) and treated with chemoradiotherapy. The radiation method was an external beam radiotherapy (EBRT) and remote after loading system (RALS). The chemotherapy was 5-fluorouracil (FU) and gemcitabine by intravenous injection. Three patients had unresectable and 2 had recurrent CCC. As for the side effects, 4 patients had a slight neutropenia and 1 had an uncontrollable gastric bleeding. No patient had cholangitis. The mean survival time for unresectable and recurrent CCC was 13.7 months and 17 months, respectively. Our results indicated that chemoradiotherapy had been consistent with efficacy in patients with unresectable and recurrent CCC. (author)

2007-11-01

89

As time goes by? The fallacy of thrombolysis in STEMI networks  

British Library Electronic Table of Contents (United Kingdom)

Primary percutaneous coronary intervention (PPCI) is superior to thrombolysis (TL) as reperfusion therapy in ST-elevation myocardial infarction (STEMI). TL is a rapidly available, but semi-effective therapy (effective reperfusion in 50% of patients only), whereas PPCI is a potentially delayed, but highly effective therapy (effective reperfusion in >90%). Since TL loses its efficacy beyond 2?3?h after symptom onset, it is a significant reperfusion alternative to PPCI in early presenters only. The individual decision to treat an early presenter with PPCI or TL requires the evaluation of the time delay between potential start of TL or PPCI, the PCI-related delay (PRD). PRD is greatest, if TL is given in the prehospital setting. Until now, prehospital TL as the most rapidly available reperfusi...

2011-01-01

90

Tetracycline hydrochloride sclerotherapy; renal, hepatic, ovarian, and perivesical cysts  

Energy Technology Data Exchange (ETDEWEB)

To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the remaining five the cyst recurred. In one of ...

2000-11-01

91

Percutaneous transluminal angioplasty and thrombolysis in the management of insufficient hemodialysis access: Long-term patency rates and factors affecting patency rates  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the success rates, long-term patency rates and factors affecting the patency rates of percutaneous transluminal angioplasty(PTA) and thrombolysis in the management of insufficient access during hemodialysis. Between January 1991 and March 1995, 37 insufficient shunts(23 native fistulae and 14 graft fistulae) were treated in 31 patients. PTA was performed in 24 shunts, and thrombolysis in 13;in seven of these latter, thrombolysois was followed by PTA. The success and long-term patency rates of PTA and thrombolysis were evaluated. Shunts were subdivided according to a patient's age, type and age of the shunt, and number and length of the stenosis, and the degree of residual stenosis and in each subgroup, patency rates was compared. The overall success rate of PTA and thrombolysis for insufficient hemodialytic access was 78.4%(29/37). The success rates of PTA and thrombolysis were 91.7%(22/24) and 53.8%(7/13), respectively. The patency rates of ...

1997-10-01

92

Percutaneous transluminal angioplasty and stent insertion in central venous steno-occlusion  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) and stent insertion in central venous steno-occlusion. Between August 1992 and January 1998, 11 patients with symptomatic central venous steno-occlusion (six stenoses and five occlusions) underwent pereutaneous treatment. Eleven PTAs were performed and stents were introduced in two patients because of incomplete PTA. During follow-up, a total of eight revisions were performed in five patients with recurrence (six stenoses and two occlusions). Success and long term patency rates were evaluated. The length and degree of the lesion and degree of residual stenosis, as well as pressure gradient through the lesion and decrease of the gradient after PTA, were correlated with patency rates. Complications during the procedures and follow-up period were evaluated. The overall success rate was 89.5%;those of primary and revision intervention were 90. 9% and 87.5%, respectively. Primary and revision ...

1998-12-01

93

Multiscale modeling of transdermal drug delivery  

Science.gov (United States)

This study addresses the modeling of transdermal diffusion of drugs, to better understand the permeation of molecules through the skin, and especially the stratum corneum, which forms the main permeation barrier of the skin. In transdermal delivery of systemic drugs, the drugs diffuse from a patch placed on the skin through the epidermis to the underlying blood vessels. The epidermis is the outermost layer of the skin and can be further divided into the stratum corneum (SC) and the viable epidermis layers. The SC consists of keratinous cells (corneocytes) embedded in the lipid multi-bilayers of the intercellular space. It is widely accepted that the barrier properties of the skin mostly arises from the ordered structure of the lipid bilayers. The diffusion path, at least for lipophilic molecules, seems to be mainly through the lipid bilayers. Despite the advantages of transdermal drug delivery compared to other drug delivery routes such as oral dosing and injections, the low ...

2006-01-01

94

Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation  

International Nuclear Information System (INIS)

Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). ...

2000-09-01

95

A simplified method of opacifying and mixing acrylic cement for percutaneous vertebroplasty: a clinical and in vitro study.  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated with injection of the cement mixture. Complete (CR) ...

96

A Simplified Method of Opacifying and Mixing Acrylic Cement for Percutaneous Vertebroplasty: A Clinical and In Vitro Study  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast{sup TM} 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated with injection of the cement mixture. ...

2005-06-15

97

Routine upfront abciximab versus standard periprocedural therapy in patients undergoing primary percutaneous coronary intervention for cardiogenic shock: The PRAGUE-7 Study. An open randomized multicentre study  

British Library Electronic Table of Contents (United Kingdom)

Background: The outcome of acute myocardial infarction (AMI) complicated with cardiogenic shock is poor. The aim of this study was to analyse, whether upfront abciximab administration could improve the outcomes of cardiogenic shock. Methods: This multicentre open trial randomized 80 patients with AMI complicated by cardiogenic shock expected to undergo primary PCI into group A (routine upfront-pre-procedural-abciximab bolus followed by 12-h abciximab infusion) and group B (standard therapy). The study primary objective was 30-day combined outcome (death/reinfarction/stroke/new severe renal failure). Results: PCI was technically successful in 90% (A) versus 87.5% (B) patients. Abciximab was used in 100% (A) versus 35% (B). The primary endpoint occurred in 17 group A patients (42.5%) and 11 ...

2011-01-01

98

Retrieval of intravascular foreign bodies with goose neck snare  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is highly effective ...

2004-03-01

99

Percutaneous Treatment of Malignant Jaundice Due to Extrahepatic Cholangiocarcinoma: Covered Viabil Stent Versus Uncovered Wallstents  

International Nuclear Information System (INIS)

To compare clinical effectiveness of Viabil-covered stents versus uncovered metallic Wallstents, for palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, 60 patients were enrolled in a prospective and randomized study. In half of the patients a bare Wallstent was used, and in the other half a Viabil biliary stent. Patients were followed up until death. Primary patency, survival, complication rates, and mean cost were calculated in both groups. Stent dysfunction occurred in 9 (30%) patients in the bare stent group after a mean period of 133.1 days and in 4 (13.3%) patients in the covered stent group after a mean of 179.5 days. The incidence of stent dysfunction was significantly lower in the covered stent group (P = 0.046). Tumor ingrowth occurred exclusively in the bare stent group (P = 0.007). Median survival was 180.5 days for the Wallstent and 243.5 days for the Viabil group (P = 0.039). Complications and mean cost were similar in the two groups. Viabil ...

2010-02-01

100

New stent developments for peripheral arterial occlusive disease; Neue Stententwicklungen fuer die periphere arterielle Verschlusskrankheit  

Energy Technology Data Exchange (ETDEWEB)

Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren ...

2010-01-15

 
 
 
 
101

Incidence of low bioavailability of leuprolide acetate after percutaneous administration to rats by dissolving microneedles  

British Library Electronic Table of Contents (United Kingdom)

Two-layered dissolving microneedles of which acral portion contained leuprolide acetate (LA) as solid dispersion were prepared with sodium chondroitin sulfate as the base and the systemic absorption efficiency of LA was studied in rats after administration to their abdominal skin. A patch contained 100 dissolving microneedles of which length and basement diameter were 469.8+/-4.7mm and 284.5+/-9.8mm, where LA content was 14.3+/-1.6mg. In vitro dissolution experiment showed that LA was released from dissolving microneedle patch within 3min. LA was stable in the patch, % recoveries for 3 months were 102.2+/-1.9-95.3+/-1.9%. One and half-patch of LA dissolving microneedles were administered to the rat skin and plasma LA concentrations were measured by LC-MS/MS. Plasma LA concentrations increa...

2011-01-01

102

Endoluminal vascular prostheses; Endoluminale Gefaessprothesen  

Energy Technology Data Exchange (ETDEWEB)

Endoluminal vascular prostheses that can be implanted by percutaneous routes represent the most recent development in vascular interventional radiology. Various commercially available types of prosthesis are presented and the construction principles and applications are described. At present secure indications for the implantation of endoluminal prostheses are limited to the elimination of aneurysms and arteriovenous fistulae of the large vessels near the trunk in sections that do not cross a joint. The wide use in peripheral occlusive diseases cannot yet be recommended because confirmed data are not available. (orig.) [German] Endoluminale Gefaessprothesen, die perkutan implantierbar sind, stellen die juengste Entwicklung in der vaskulaeren interventionellen Radiologie dar. Verschiedene kommerziell erhaeltliche Prothesentypen werden vorgestellt, ihr Konstruktionsprinzip und ihre Applikation erlaeutert. Die gesicherten Indikationen zur endoluminalen ...

2000-06-01

103

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

104

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and MRCP are virtually ...

2010-07-01

105

Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation  

International Nuclear Information System (INIS)

Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along ...

2009-05-01

106

Analysis of the placement of multiple metallic stents in the treatment of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the clinical efficacy of multiple stents placement in the management of hilar cholangiocarcinoma, especially in the complex cases of which the hepatic ducts are invaded. Methods: Forty-five consecutive patients with hilar cholangiocarcinoma were treated with percutaneous transhepatic placement of two or three self-expandable metallic endoprostheses. The cause of hilar obstructions in these patients were all cholangiocarcinoma, including Bismuth classification type II (n 12), IIIa (n 17), IIIb (n 10), and IV (n 6). Two or 3 stents were placed in the configuration of T, Y or X over the strictures. Results: Stent placement with 2 or 3 endoprostheses was successful in all patients. All patients showed significant decrease in serum bilirubin level. The mortality rate within 30 days of stent placement was 2.2% (1/45). The mean survival and stent patency times were 215.3 d (26- 516 d) and 181.5 d (26-473 d), respectively. Conclusion: Deploying of ...

2007-11-01

107

Transcutaneous oximetry compared to ankle-brachial-index measurement in the evaluation of percutaneous transluminal angioplasty  

International Nuclear Information System (INIS)

Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the ...

2007-11-01

108

Diagnosis and therapy of Budd-Chiari syndrome; Diagnostik und Therapie des Budd-Chiari-Syndroms  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no ...

1998-09-01

109

Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent  

Energy Technology Data Exchange (ETDEWEB)

We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate ...

2007-10-15

110

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear relationship exists between ...

1985-06-02

111

Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible ...

2007-08-15

112

Prospective benefit and effect of lipiodol marking in hepatocellular carcinoma; Moeglicher Nutzen und Auswirkung einer Lipiodolmarkierung auf die Histologie beim hepatozellulaeren Karzinom  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the benefit and the effect of intraarterial lipiodol application on histological analysis of patients suspected of having HCC. To determine whether lipiodol marking leads to a better biopsy result and how lipiodol or a transarterial chemoembolization influences the histological diagnosis. Materials and Methods: Two groups of patients were examined. Group A included 14 patients highly suspected of having an HCC which had previously been unsuccessfully biopsied. A transarterial embolization with lipiodol was performed in these patients to mark intrahepatic tumors which could not otherwise be defined in unenhanced CT. A biopsy was then repeated. Group B included 22 patients undergoing therapy using transarterial chemoembolization (TACE). A biopsy was performed to support the diagnosis of a multifocal HCC before changing the therapy. Results: The transversal diameters of the biopsied tumors were similar in both groups (A: 22 mm; B: 21 mm). The length of ...

2005-10-01

113

Optimizing the Protocol for Pulmonary Cryoablation: A Comparison of a Dual- and Triple-Freeze Protocol  

International Nuclear Information System (INIS)

The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not significantly different ...

2010-12-01

114

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo differenti procedure ablative percutanee  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...

1999-12-01

115

Evaluation of a novel radiopacifiying agent on the physical properties of surgical spineplex.  

Science.gov (United States)

Polymethlylmethacrylate (PMMA) is the most frequently used cement for percutaneous vertebroplasty and kyphoplasty. To aid visualisation during surgery cements are doped with radiopacifying agents such as Barium sulphate (Ba(2)SO(4)) or Zirconium Dioxide (ZiO(2)). Mounting research suggests that these agents may impair the biocompatibility of the cements. However, incorporating an alternative radiopacifier agent with excellent biocompatibility would be a significant step forward. Bioactive radiopaque glasses incorporating elements such as strontium (Sr) and zinc (Zn), known to have beneficial and therapeutic effects on bone, are of great interest in this respect. In this study, the Ba(2)SO(4) of the commercially available Spineplex was incrementally replaced with a radiopaque therapeutic glass composition. The resulting effects on cement setting time, peak isotherm, ultimate compressive strength, Young's modulus (up to 30 days cement maturation) and radiopacity were ...

2009-08-18

116

Computerized tomography-guided neurolytic splanchnic nerve block  

International Nuclear Information System (INIS)

Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with severe chronic abdominal pain. It is used as ...

1997-01-01

117

Suburban amoebiasis. CT and US findings and percutaneous treatment of amoebic liver abscess; Amebiasi sub-urbana: aspetti diagnostici con tomografia computerizzata ed ecografia e trattamento percutaneo degli ascessi amebici del fegato  

Energy Technology Data Exchange (ETDEWEB)

The study reports ultrasonography and computerise tomography findings in 16 patients with amoebic abscesses, 12 of whom lived in a temperate peripheral area north-east of Naples (Italy). All patients have a clinical-diagnostic condition called sub-urban amoebiasis. The personal experience with the US guided therapeutic drainage of amoebic abscess with repeated cavity washing, which is important for positive parasitology. Combined US and CT assessment facilitated the diagnosis of amoebiasis and its differentiation from pyogenic abscess and hepatoma. [Italian] La colonizzazione epatica rappresenta la localizzazione piu' comune dell'amebiasi extraintestinale e gli ascessi epatici ne costituiscono la manifestazione piu' frequente sviluppandosi nel 3-9 % dei pazienti affetti da infezione parassitaria. Diversi studi confermano che la terapia medica dell'amebiasi risulta piu' efficace quando viene associato il drenaggio percutaneo degli ascessi ...

2000-03-01

118

MRI in postoperative assessment of univentricular heart disease: correlation with echocardiography and angiography; MRT in der postoperativen Diagnostik bei funktionell univentrikulaerem Herz: Korrelation zu Echokardiographie und Kardangiographie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary arteries in 30/31 ...

2002-12-01

119

In vitro percutaneous absorption of metal compounds.  

Science.gov (United States)

It is well known that contact with metals can be responsible for allergic contact dermatitis; also, there is experimental evidence that nickel ions are readily available on the surface of used coins containing nickel and copper. The aim of this study was to prove that metal powders of nickel (Ni), cobalt (Co) and chromium (Cr) dispersed in synthetic sweat are oxidised into respective ions that can permeate the skin. Suspensions of 5 g of metal powder (Ni, Co and Cr) in 100 mL of synthetic sweat at pH 6.5 were prepared and shaken with a stirring plate at room temperature for 30 min. Human skin membranes were set up in Franz-diffusion cells and 2 mL of the freshly made suspension were applied to the outer surface of the skin for 24h. The appearance of metal ions in the aqueous receptor phase (NaCl 0.9%) was quantified by Electro Thermal Atomic Absorption Spectroscopy (ETAAS). Also, metals ions were analysed using Differential Pulse Polarography (DDP), Differential Pulse Voltammetry (DPV) ...

2007-02-23

120

In vitro examination of the visibility of 11 stent catheters with real-time MR imaging; In-vitro-Untersuchung der Sichtbarkeit von 11 Stentkathetern unter Echtzeit-MR-Kontrolle  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an evaluation of the visibility of the tip of the stent-catheter and ...

2004-09-01

 
 
 
 
121

Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART); Perkutane Therapie inoperabler maligner Stenosen und Verschluesse der Gallenwege mit einem neu entwickelten selbstexpandierbaren Nitinolstent (SMART)  

Energy Technology Data Exchange (ETDEWEB)

Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79% (n=15) of patients ...

2002-10-01