Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...
This paper deals with construction types of high temperature heat exchangers, their circulation loops and temperature differences. Most attention is given to gas dynamics, convective heat transfer, convection and radiantheat transfer interaction in high temperature heat exchangers. The ways of heat transfer augmentation and efficient heat exchanger construction are discussed.
This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable ...
Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local ...
The goal of this project was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and the upper use temperature by 86 to 140 degrees fahrenheit (30 to 60 degrees celsius). Meeting this goal is expected to result in energy savings of 35 trillion Btu/year by 2020 and energy cost savings of approximately $230 million/year. The higher-strength H-Series cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat treating industry, including radiant burner tubes. The project was led by Duraloy Technologies, Inc., with research participation by Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies.
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiantheating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.
Direct Flame Impingement involves the use of an array of very high-velocity flame jets impinging on a work piece to rapidly heat the work piece. The predominant mode of heat transfer is convection. Because of the locally high rate of heat transfer at the surface of the work piece, the refractory walls and exhaust gases of a DFI furnace are significantly cooler than in conventional radiantheating furnaces, resulting in high thermal efficiency and low NOx emissions. A DFI furnace is composed of a successive arrangement of heating modules through or by which the work piece is conveyed, and can be configured for square, round, flat, and curved metal shapes (e.g., billets, tubes, flat bars, and coiled bars) in single- or multi-stranded applications.
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiantheat testing. (LEW)
... Abstract : Interlaboratory evaluation of the Radiant Panel Method (ASTM E 162-67) for flame spread testing of two flexible foam and one hardboard ...
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the useful ...
A gas-fired boiler plant comprises a burner bed extending over a flat surface and heat exchanger pipes arranged above the burner bed, parallel to the said surface. The heat exchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heat exchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiantheat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ensure that bent-over portions point towards the burner bed and the rising flue gased ...
Disclosed is a gas-fired cooktop for a range which provides high thermal efficiency and low emissions of air pollutants, particularly low levels of NO{sub x}. The cooktop includes a perforated tile burner which radiates infrared energy upward at a high flux rate to rapidly quench burner gas temperatures and inhibit the formation of NO{sub x}. A perforated glass-ceramic jet plate positioned between the burner and a cooking vessel transmits most of the radiant infrared energy from the burner to the vessel and also forms jets of combustion products which are directed against the bottom of the vessel fo convective heating. Thermal efficiencies of up to about 70% and NO{sub x} emissions as low as about 15ppM are achieved by the cooktop.
The number of spent fuel storage facilities in the world continues to increase because of "Wait and See" policies and delay of a permanent disposal plan. The temporary spent fuel storage concept is changing to a pre-disposal storage concept. Strengthened safety concepts are required for expanded spent fuel storage facilities and sites. The Korea Hydro and Nuclear Power Company is planning to construct a reinforced concrete MACSTOR-400 facility at Wolsung. In concrete dry spent fuel storage structures, cracks can occur due to radiantheat and environmental chloride. The likelihood of cracking increases over time. Research on changes in shielding performance from one collinear crack in the surface of a concrete facility has been carried out. However there is no research about public radiolog...
This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)
This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available
A laboratory model of a TPV generator in the kilowatt range was developed and tested. It was based on methane/oxygen combustion and a spectrally matched selective emitter/collector pair (ytterbia emitter-silicon PV cell). The system demonstrated a power output of 2.4 kilowatts at an overall efficiency of 4.5{percent} without recuperation of heat from the exhaust gases. Key aspects of the effort include: (1) process development and fabrication of mechanically strong selective emitter ceramic textile materials; (2) design of a stirred reactor emitter/burner capable of handling up to 175,000 Btu/hr fuel flows; (3) support to the developer of the production silicon concentrator cells capable of withstanding TPV environments; (4) assessing the apparent temperature exponent of selective emitters; and (5) determining that the remaining generator efficiency improvements are readily defined combustion engineering problems that do not necessitate breakthrough technology. The ...
This paper describes the high-temperature (1500/sup 0/C or higher) heating technology by combusting natural gas. The theoretical adiabatic flame temperature is 1957/sup 0/C at the theoretical air ratio and 2801/sup 0/C at the theoretical oxygen ratio. The flame temperature is increased by 40/sup 0/C every 1%-increase of oxygen up to 25% of the concentration of oxygen and by 28/sup 0/C to 30% of it. The flame temperature is increased by 37 to 38/sup 0/C every 100/sup 0/C-increase of the temperature of preheated air. The practical temperatures are significantly lower than the theoretical ones. The ceramic calciner is provided with a two-stage burner for 1600 to 1800/sup 0/C which can use also the oxygen-riched air. The glass melting furnace is operated at 1500/sup 0/C and the flat flame burner is used for a single kiln. A stabilizing burner is used for reducing the multing time for the steel making electric arc furnace. A high-temperature (1700/sup 0/C) ...
The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the ...
The pathway to hydrogen generation entirely from renewable energy and material sources probably goes by a transitional period with the utilization of hybrid fossil/renewable integrated systems. Solar steam reforming of methane is set in this context, specifically suited for a country like Italy whose actual energy policy is mainly based on the imported NG, but also characterized by convenient solar radiation levels in the Southern Regions. A new solar SMR process is being developed by ENEA, using molten nitrates as solar heat carriers and storage medium at about 550 C. The potential of this process have been proved theoretically by process simulation studies. Engineering and experimental activities aimed to the development of a prototype apparatus are now in progress in ENEA's laboratories. It is remarkable that the developed technology (MS powered SMR) can find interesting impact in the in industrial chemistry wherever it is convenient decoupling the ...
Two computational problems were worked on for this study. The first chapter examines the option of coal combustion using oxygen feed with carbon dioxide recycle to control the adiabatic flame temperature. Computer simulations using an existing state-of-the-art 3-dimensional computer code for turbulent reacting flows with reacting particles were employed to study the effects of increased carbon dioxide mole fraction on the char burnout, radiantheat transfer, metal partitioning, and NOx formation. The second chapter compares assumptions for the CO/CO{sub 2} ratio at the surface of mineral inclusions made in previous studies to predictions obtained from a pseudo-steady state kinetic model (SKIPPY) for a single porous particle. The detailed kinetic simulations from SKIPPY for varying particle sizes and bulk gas compositions were used to develop algebraic expressions for the CO/CO{sub 2} ratio that can be incorporated into metal vaporization ...
A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered air-conditioning system was 15.3 kW during an 8 h operation and the maximum value exceeded 20 kW. Solar ...
The natural convection characteristics of gas in a vertical narrow annular gap which had its bottom opened to high temperature fluid and its upper shielding exposed to low temperature sealant have been evaluated from simulated fluid experiments using water and from calculations using the three-dimensional thermal hydraulic analysis computer code THERVIS-III. The following results were obtained: (1) The critical Rayleigh number which represented the limit of convection generation increased as the aspect ratios #epsilon#_1 (height/circumference) and #epsilon#_2 (height/gap distance) increased. (2) The flow pattern along the circumferential direction was seen to depend more strongly on the radiantheat from the side wall, rather than the aspect ratios #epsilon#_1 and #epsilon#_2. (3) The temperature difference along the circumferential direction in the annular gap obtained from the calculation code coincided with that obtained from experiments ...
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column ...
... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...
The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available
We investigate a method for gene delivery to vascular smooth muscle cells using ultrasound triggered delivery of plasmid DNA from electrostatically coupled cationic microbubbles. Microbubbles...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available
The objective of this work was to identify methods of improving the performance of gas-fired radiant burners through the use of Continuous Fiber Ceramic Composites (CFCCs). Methods have been identified to improve the price and performance characteristics of the porous surface burner. Results are described.
An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.
A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm ...
The goal of this program was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and upper use temperature by 86 to 140 F (30 to 60 C). Meeting this goal is expected to result in energy savings of 38 trillion Btu/year by 2020 and energy cost savings of $185 million/year. The higher strength H-Series of cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat-treating industry. The project was led by Duraloy Technologies, Inc. with research participation by the Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies. Energy Industries of Ohio (EIO) was also a partner in this project. Each team partner had well-defined roles. Duraloy Technologies led the team by ...
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design ...
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant ...
Last year a team of US and French scientists using the Odeillo (France) 1MW/sub th/ solar furnace showed concentrated solar radiation to be an effective means for rapidly volatilizing biomass materials. The results of continuing research in the U.S. on radiant flash pyrolysis of biomass as a source of fluid fuels, industrial feedstocks and chemicals are described. Bench scale sources of intense, visible radiant energy have been used to simulate the concentrated solar flux available at the focus of solar towers. Windowed transport reactors are being developed, which act as cavity receivers for the focused radiant energy and provide a means for direct use of the radiation to rapidly pyrolyze the entering biomass. One of these reactors will be operated at the focus of the Georgia Tech 400kW/sub th/ solar furnace next August. Preliminary results from the bench scale reactor experiments, and plans for the Georgia Tech ...
Sep 19, 2011 ... (The whispering voice, on the other hand, was the latest in ultrasound directed audio technology from the firm Audio Spotlight.) The NASA ...
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...
This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.
This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.
During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiantheat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type ...
Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.
Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available
BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this ...
Research performed under this contract was divided into four tasks under the following headings: Task 1, Characterization of fly ash; Task 2, Measurements of the optical constants of slags; Task 3, Calculations of the radiant properties of fly ash dispersions; and Task 4, Measurements of the radiant properties of fly ash dispersions. Tasks 1 and 4 constituted the Ph.D. research topic of Sarbajit Ghosal, while Tasks 2 and 3 constituted the Ph.D. research topic of Jon Ebert. Together their doctoral dissertations give a complete account of the work performed. This final report, issued in two volumes consists of an executive summary of the whole program followed by the dissertation of Ghosal and Ebert. Volume 2 contains the dissertation of Ebert which covers the measurements of the optical constants of slags, and calculations of the radiant properties of fly ash dispersions. A list of publications and conference presentations ...
Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...
The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two ...
Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available
BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Doppler ultrasound (TVCD) may predict those prognostic factors...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.
Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available
BackgroundLifestyle, genetics and environmental factors are established determinants of bone density. We aimed to describe the bone characteristics of competitive top-ranked Nigerian...Full Text Available
An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available
To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...
Fourier transform infrared spectroscopy is a simple, fast, reliable and nondestructive analytical method. By using the method developed in Clark Atlanta University, consistent and reliable infrared spectral results can be obtained. An accurate radiant energy can be calculated from these infrared spectra by using a blackbody as the calibration standards. By means of the specially-designed-and-lab-made sampling inlet and the Horiba gas analyzers, the compositions of CO{sub 2}, CO, UCH, NOx and O{sub 2} etc. from the combustion exhaust gases have been on-line accurately analyzed. The commercial natural gas IR burner performed differently in the different conditions. For the methane-air combustion, at the equivalence ratio {Phi} = 1, the IR burner produced its maximum radiation efficiency, {approximately}31.4%, and the concentration of CO{sub 2} reached its maximum value, {approximately}10.7%. In the fuel-lean region, the O{sub 2} concentration in the emission gas ...
In this paper some physical mechanisms are described, which determine some new free-electron laser configurations. These mechanisms comprise some physical effects of the radiant emission of an electron beam at the interaction with the medium it is crossing. They are based on the Cherenkov effect, Smith-Purcell effect, optical klystron, Rumakhov effect and limited interaction effect. (Author).
OBJECTIVE: To evaluate the interobserver agreement of ultrasonographic assessment of finger and toe joints in patients with rheumatoid arthritis (RA) by 2 investigators with different medical backgrounds. METHODS: Ultrasonography and clinical examination were performed on 150 small joints of 30 patients with active RA. A General Electric LOGIQ 500 ultrasound unit with a 7-13-MHz linear array transducer was used. In each patient, 5 preselected small joints (second and third metacarpophalangeal, second proximal interphalangeal, first and second metatarsophalangeal) were examined independently on the same day by 2 ultrasound investigators (an experienced musculoskeletal radiologist and a rheumatologist with limited ultrasound training). Joint effusion, synovial thickening, bone erosions, and power Doppler signal were evaluated in accordance with an introduced 4-grade semiquantitative scoring system, on which the investigators ...
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof ...
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...
RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified ...
In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...
Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...
17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).
Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...
Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...
Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.
Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...
This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according...Full Text Available
Plants require solar radiation for photosynthesis and their growth is directly related to the amount received, assuming that other environmental parameters are not limiting. Therefore, precise estimation of photosynthetically active radiation (PAR) is necessary to enhance overall accuracies of plant growth models. This study aimed to explore the PAR radiant flux in the San Francisco Bay Area of northern California. During the growing season (March through August) for 2?years 2007?2008, the on-site magnitudes of photosynthetic photon flux densities (PPFD) were investigated and then processed at both the hourly and daily time scales. Combined with global solar radiation (R S) and simulated extraterrestrial solar radiation, five PAR-related values were developed, i.e., flux density-based PAR ...
A fundamental Doppler-like but asymmetric wave effect that shifts received signals in frequency in proportion to their respective source distances, was recently described as means for a whole new generation of communication technology using angle and distance, potentially replacing TDM, FDM or CDMA, for multiplexing. It is equivalent to wave packet compression by scaling of time at the receiver, converting path-dependent phase into distance-dependent shifts, and can multiply the capacity of physical channels. The effect was hitherto unsuspected in physics, appears to be responsible for both the cosmological acceleration and the Pioneer 10/11 anomaly, and is exhibited in audio data. This paper discusses how it may be exploited for instant, passive ranging of signal sources, for verification, rescue and navigation; incoherent aperture synthesis for smaller, yet more accurate radars; universal immunity to jamming or interference; and precision frequency scaling of ...
For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...
A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185
Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...
A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...
The objective of the first project period is to: make a study into materials suitable for the non-premix radiant burners (NPRB); choose the materials for the construction; make proposals for the design of the NPRB; test the different proposals with a CFD-model. In pursuit of finding a suitable material it is necessary first to estimate the maximum temperature that will occur in the burner. It has been estimated that the maximum adiabatic flame temperature will be about 2400-2500 K. The maximum temperature in the burner will of course never reach this level. A more realistic temperature was estimated to 2100-2300 K. The final choice was made after having contacted some of the leading producers. It was possible to find one producer that could produce burners of one of the suggested materials, zirconia. Several construction ideas for the NPRB have been discussed and some of them tested with a CFD-model. The proposed burner concept has been modified in order to obtain ...
... turbine blade heat-transfer and study the heat-transfer augmentation in idealized geometry and its ... responsible for heat transfer augmentation. ...
The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.
The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...
This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm"2, 8 x 8 cm"2 and 10 x 10 cm"2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the results obtained are analyzed then it is ...
The advances in laser technology have made available very short and intense laser pulses which can be used to seed a high-gain single-pass free-electron laser (FEL) amplifier. With these seed pulses, a regime of the FEL interaction where the radiation evolution is simultaneously dominated by nonlinear effects (saturation) and time-dependent effects (slippage) can be explored. This regime is characterized by the propagation of a solitary wavelike pulse where the power of the optical wave grows quadratically with time, its pulse length decreases and the spectral bandwidth increases. We analyze the interplay between the field and particle dynamics of this propagation regime which was studied before and termed super-radiance. Furthermore we analyze the properties of the strong higher-order harmonic emission from this wave and its behavior when propagating in a cascade FEL. The super-radiant pulse is indeed capable of passing through the stages of a cascade FEL and to ...
An experimental investigation of premixed methane-air combustion within the one-dimensional porous ceramic burners for various burner configurations is presented. The burner is nonhomogeneous because of different pore size ceramic block used in different section of the burner. Therefore, the thermophysical and transport properties are nonuniform along the burner core length. The burners are constructed of partially stabilized zirconia. The CO and NO{sub x} emissions, flame speed, and flame stability are examined and compared at lean equivalence ratios for five different burner configurations. The sandwich-structured burner has very favorable flame stabilizing characteristic due to the radiation reflecting region. While the combustion proceeds at faster rate than other burner configurations, the radiation reflecting region and the exit surface have low temperature. Thus the NO{sub x} emission can be kept at the same low level as the other burner configurations exhibit., It is found that ...
AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.
In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)
Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry
Theoretical and experimental results of investigating a cylindrical heat receiver with secondary reflectors are presented. One important element of solar thermal power plants (STPP) is the heat receiver. Several forms of heat receiver exist; the main form is the heat receiver of cavity form (including cylindrical, rectangular, and cubic heat receivers with a noncircular aperture). The linear dimension of such heat receivers is equal to, or larger than, the theoretical diameter of the concentrator focal spot.
This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.
This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.
In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. ...
This is the first text and reference book to be devoted completely to the very important and timely subject of heat transfer augmentation. This book is of equal appeal to both researchers and designers of heat transfer equipment.
To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the remaining five the cyst ...
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by two radiologists. ...
The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The ...
Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...
Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to determine the strength ...
Approximately 400 people die from extreme heat each year in the United States, and the risk of heat waves may increase as a result of global climate change. Despite the risk of heat-related morbidity...Full Text Available
Several heat transfer augmentation mechanisms contribute to the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. Among those contributions, that of heat exchange was numerically analyzed and characteristically elucidated by the unsteady direct contact heat conduction at the time of impingement between the laden particles and heat transfer surface. In other words, if the contact time is short between the particles and heat transfer surface, the former is heated by heat stored in the latter as a heat capacity. In such a region, the heat quantity to be transferred to the particles changes by not only the thermal property value (heat capacity multiplied by heat conduction coefficient) of ...
This textbook contains the following main topics: Heat conductivity, convection, condensation and evaporation, radiation heat transfer and heat exchangers. It includes the physical foundations for all these aspects and many examples. (orig.)
This volume is divided into the following sections: (1) fundamentals of convection heat transfer; (2) fundamentals of heat transfer with impinging jets; and (3) fundamentals of heat transfer augmentation. Separate abstracts were prepared for most papers in this volume.
An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.
Heat transfer augmentation by straight grid spacers in rod bundles is studied for single phase flow and for post critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single phase flow is also examined. Governing heat transfer mechanisms are analyzed, and predictive formulations are established. For single phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. 18 refs.
The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented
The behavior of air flows in complex heat exchanger passages is reviewed with a focus on the heat transfer effects of boundary-layer development, turbulence, spanwise and streamwise vortices, and wake management. Each of these flow features is discussed for the plain, wavy, and interrupted passages found in contemporary compact heat exchanger designs. Results from the literature are used to help explain the role of these mechanisms in heat transfer enhancement strategies.
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This ...
A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heat exchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heat exchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heat exchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The variables collected in the experimental procedures was gathered in the ...
This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable ...
The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera ...
The heat capacity and heat of fusion were measured for a number of minerals using differential scanning calorimetry (DSC). The DSC measurements showed that the heat of fusion for the minerals is very low compared to the heat of fusion for pure crystalline phases reported elsewhere. A model for the melting behaviour of mineral materials in terms of melting interval, heat capacities and heat of fusion has been developed. The only model input is the chemical composition of the mineral material. The model was developed to be implemented in a detailed model of a cupola furnace, thus the focus for the development was not only precision but also to obtain a model that was continuous and differentiable. The model is based on several different submodels that each covers a part of the heating and melting of rocks. Each submodel is based on large ...
This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.
The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.
The bibliography contains citations concerning industrial uses and design of microwave heating equipment. Included are heating and drying of paper, industrial process heat, vulcanization, textile processing, metallurgical heat for sintering and ceramic manufacturing, food processing, and curing of polymers.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)
Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.
The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.
Several aspects of heat transfer at the annular two phase flow regime are considered. Nucleate boiling is supposed to be absent. Theoretical solutions for cases of laminar and turbulent flow in the liquid film, respectively, are considered, when steam presence does not effect the heat transfer. Heat transfer in annular flows is also considered, where steam phase consists totally or partially of the so-called incondensable gas. In this case steam phase can be a considerable resistance to heat transfer.
Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical ...
The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...
The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. Percutaneous routes that ...
SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...
The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).
The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)
Feasibility of mushy state forming of magnesium alloys making use of resistance heating was examined. Magnesium alloys, AZ31, AZ61 and AZ91, were taken up as experimental materials and cylindrical billets with a diameter of 15 mm and a height of 20 mm were used for both resistance heating and forming experiments. Input heat control was applied to the billet heating and insertion of thin discs of austenitic stainless steel with a low thermal conductivity between the billet and copper electrodes was attempted in order to improve the efficiency of the billet heating. Results were summarized as follows. (1) Resistance heating by input heat control was successful to heat the billets to their respective mushy state. (2) Insertion of the discs was very helpful in heating the billets and realized the ...
The paper investigates the effect of the wall heat flux ratio on the local heat transfer augmentation in a square channel with two opposite in-line ribbed walls for Reynolds numbers from 15,000 to 80,000. The square channel composed of 10 isolated copper sections has a length-to-hydraulic diameter ratio of 20. The rib height-to-hydraulic diameter ratio is 0.0625 and the rib pitch-to-height ratio equals 10. Six ribbed side to smooth side wall heat flux ratios are studied for four rib orientations. The results show that the ribbed side wall heat transfer augmentation increases with increasing ribbed side to smooth side wall heat flux ratios, but the reverse is true for the smooth side wall heat transfer augmentation. The average heat transfer augmentation of the ribbed side and smooth side wall decreases slightly with increasing wall ...
Heating and cooling by impinging jets is widely used in various engineering applications, due to the high heat transfer rates prevailing in the vicinity of the stagnation point. The authors have been able to utilize acoustically excited turbulence for the...
In this paper, the authors first describe a fourth order accurate finite difference discretization for both the Laplace equation and the heat equation with Dirichlet boundary conditions on irregular domains. In the case of the heat equation, they use an i...
The advantages of district heating as an environmental-friendly and energy-saving technique are reviewed. The role of district heating as part of the Dutch national plan to reduce the emission of acidification and greenhouse gases by respectively 50 and 25 percent is clarified. 12 Tabs. (A.S.).
In heat-shocked tomato cell cultures, cytoplasmic heat shock granules (HSGs) are tightly associated with a specific subset of mRNAs coding mainly for the untranslated control proteins. This messenger...Full Text Available
In addition to inducing new transcriptional activities that lead within a few hours to the accumulation of heat shock proteins (Hsps), heat shock activates within minutes the major signaling transduction...Full Text Available
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
We present a high temperature heat oven with merits of conventional heat pipe oven and study ots thermal characteristics. The oven consists of stainless steel body and heating part of three layers of ceramic tubes. We obtained the maximum temperature of about 1350. deg. C at the center which was measured by thermocouple and infrared thermometer. And we compared the heating characteristics in the cases of external heating and no extent heating. It was applied to self diffraction experiment in the samarium gas which was one of the high melting point material.
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).
The Stefan problem involving a source term is considered in this technical note. As an example, planar solidification with time-dependent heat generation in a semi-infinite plane is solved by use of a perturbation technique. The perturbation solution is validated by reducing the problem to the case without heat generation whose exact solution is available. An application to the case with constant heat generation is presented, for which a closed-form solution is obtained. The effects of heat generation and Stefan number on the evolution of solidification are examined using the perturbation solution.
Heat-of-fusion storage materials for low temperature latent heat storage in the temperature range 0-120 C are reviewed. Organic and inorganic heat storage materials classified as paraffins, fatty acids, inorganic salt hydrates and eutectic compounds are considered. The melting and freezing behavior of the various substances is investigated using the techniques of Thermal Analysis and Differential Scanning Calorimetry. The importance of thermal cycling tests for establishing the long-term stability of the storage materials is discussed. Finally, some data pertaining to the corrosion compatibility of heat-of-fusion substances with conventional materials of construction is presented.
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...
The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)
... mass of gray gas by thermal radiation; An experimental study of the turbulent wake behind a cone at M = 5; Heat transfer augmentation by steady ...
heat transfer augmentation was found to increase with decreasing length scale but no optimum length scale was found. Heat transfer augmentation due to turbu- ...
A numerical study has been conducted to examine the heat transfer from a metal foam-wrapped solid cylinder in cross-flow. Effects of the key parameters including the free stream velocity and characteristics of metal foam such as porosity, permeability, and form drag coefficient on heat and fluid flow are examined. Being a determining factor in pressure drop and heat transfer increment, the porous layer thickness is changed systematically to observe that there is an optimum layer thickness beyond which the heat transfer does not improve while the pressure drop continues to increase. This has been verified by the application of Bejan?s Intersection of Asymptotes method. Results have been compared to those of a finned-tube heat exchanger to observe much higher heat transfer rate with reasonab...
Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.
Heat-transfer augmentation by straight grid spacers in rod bundles is studied for single-phase flow and for post-critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single-phase flow is also examined. Governing heat-transfer mechanisms are analyzed, and predictive formulations are established. For single-phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. The effect of local velocity increasing near swirling spacer is considered. For post critical heat flux (CHF) dispersed flow, the heat transfer by thermal radiation, fin cooling, and vapor convection near the spacer are calculated. The predictions are compared with experimental data with satisfactory agreement.
A numerical analysis is made of the unsteady flow and heat transfer characteristics of mixed convection in a vertical block-heated channel with and without installing an inclined plate above an upstream block. Parameter studies including the inclined plate angle, Reynolds number (ranging from 260 to 530), and Grashof number (in the range of 0--3,200,000) on heat transfer performance have been explored in detail. The results show that the installation of an inclined plate in the vertical block-heated channel can effectively augment the blocks` heat transfer performance in the channel. This can be applied to heat exchangers.
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
The molar heat capacities of chloroform, dichloromethane, methanol, acetonitrile, acetone, dimethyl sulfoxide, benzene, dimethylformamide, toluene, and cyclohexane, as well as their deuterated isotopologues, were measured using a multi-channel heat conduction TAM (Thermal Activity Monitor) III microcalorimeter. In addition, the apparent molar heat capacities of some of the associated dilute aqueous solutions (0.0039 i < 0.0210) were also measured. A temperature drop method from (298.15 to 297.15) K at 0.1 MPa was employed. The corresponding heat capacities were determined from the integration of the measured heat flow. The heat capacity results are shown to be in good to very good agreement with the available literature values. In addition, good correlations were obtained for the effect of isotopic substitution on both molar heat capacity ...
1 - Description of program or function: The COOLOD-N2 code provides a capability for the analyses of the steady-state thermal-hydraulics of research reactors. This code is a revised version of the COOLOD-N code, and is applicable not only for research reactors in which plate-type fuel is adopted, but also for research reactors in which rod-type fuel is adopted. In the code, subroutines to calculate temperature distribution in rod-type fuel have been newly added to the COOLOD-N code. The COOLOD-N2 code can calculate fuel temperatures under both forced convection cooling mode and natural convection cooling mode. A 'Heat Transfer package' is used for calculating heat transfer coefficient, DNB heat flux etc. The 'Heat Transfer package' is a subroutine program and is especially developed for research reactors in which plate-type fuel is adopted. In case of rod-type fuel, DNB heat flux is ...
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, ...
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with ...
A method of augmenting heat transfer in the interior of a fluid or from the interface of a solid in contact to a fluid by utilizing electro hydrodynamic (EHD) phenomena has the following advantages: the heat transfer can be effected by using a relatively small, light-weight high voltage source and some simple structural members; no vibration and noise are generated; the method has a control function to control heat transfer by adjustment of field and voltage; and this method is effective in cost-saving. It is mass transfer by the electric force caused by interaction between true charges or polarized charges in a fluid and external electric filed that plays an important role in most of such heat transfer augmentation methods by EHD. Examples of heat transfer augmentation by EHD phenomena include electricaly induced convection, contribution of EHD effect to heat ...
The authors solve the two-dimensional stefan problem of solidification in a half-space, where the heat flux at the wall is a slightly varying function of positioning along the wall, by means of a large Stefan number approximation (which turns out to be equivalent to a small time solution), and then by means of the Heat Balance Integral Method, which is valid for all time, and which agrees with the large Stefan number solution for small times. A representative solution is given for a particular form of the heat flux perturbation.
This book presents papers on internal combustion engines. Topics considered include the influence of partial suppression of heat rejection on performance and emissions, duothermic combustion, turbochargers made of sintered silicon nitrides, heat flux, low heat rejection engines, exhaust energy recovery, combustion chamber insulation, computerized simulation, heat transfer, friction, hoop stress effects, and bonding ceramics and metals.
Long-term heat acclimation (AC, 30d/34°C) is a phenotypic adaptation leading to increased thermotolerance during heat stress (HS, 2 h 41°C). AC also renders protection against...Full Text Available
The heat transfer augmentation is reviewed in view of high temperature heat exchangers illuminating the contribution of radiative heat transfer. A number of means and/or devices are presented as well as the sophisticated concept which will be promoted to the extended applications in matured industries such as iron and steel, oir refinery, petro-chemical. It should be emphasized that the more creative and innovatory technology has to be promoted in order to stimulate and refresh the foregoing industries, recognizing the increasing importance of the energy resources.
An experimental study was undertaken to determine for the turbulent regime the heat transfer and fluid flow characteristics of a heat exchange array of unperforated, and perforated brass plates with 33% of the plate area open. In both cases, the plates were aligned parallel to the flow direction. For the flow conditions examined, the results showed enhancement of heat transfer and friction factor for the perforated array.
Chinese hamster lung fibroblasts V79 cells were treated with heat stress for 4 weeks with short duration (15 min) heat shock every alternate day in culture. It was observed that Hsp...Full Text Available
A great deal of energy is necessary to manufacture castings, the greater part of which is wasted. Some general instructions are given on how to keep this part as low as possible. This is discussed particularly using the example of a heat recovery plant for foundries, especially in the melting and cooling of castings with the use of cupola furnace stack gas to produce hot gas. Further variants for recovering heat from the individual stages of a foundry process are listed. There are data on using this heat in operation.
Apparent molar heat capacities for KI[sub 3](aq) were determined from flow-microcalorimetric measurements of KI(aq) solutions containing dissolved iodine. From these, the conventional partial molar heat capacity C[sub p,2][sup [infinity
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)
Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.
The present study numerically investigates the enhancement of forced convective heat transfer from a single circular cylinder embedded in a packed bed of spherical particles confined by two impermeable parallel plates. The heat transfer results from the heated cylinder, with and without the presence of a porous medium, are compared. The results show that the presence of the porous particles enhances the heat transfer from the cylinder; however, the significant heat transfer augmentation is produced at high Re due to the effect of thermal dispersion. In addition, the effect of Re on Nut is much greater than that of kr and Bi in the porous channel. It is also found that the %?p is much higher than %HTE producing from packing the empty channel.
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...
We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or ...
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
In order to describe quantum heat engines, here we systematically study isothermal and isochoric processes for quantum thermodynamic cycles. Based on these results the quantum versions of both the Carnot heat engine and the Otto heat engine are defined without ambiguities. We also study the properties of quantum Carnot and Otto heat engines in comparison with their classical counterparts. Relations and mappings between these two quantum heat engines are also investigated by considering their respective quantum thermodynamic processes. In addition, we discuss the role of Maxwell's demon in quantum thermodynamic cycles. We find that there is no violation of the second law, even in the existence of such a demon, when the demon is included correctly as part of the working substance of the heat engine.
This experiment investigated the effects of free-stream turbulence intensity, length scale, Reynolds number, and leading-edge velocity gradient on stagnation-region heat transfer. Heat transfer was measured in the stagnation region of four models with elliptical leading edges downstream of five turbulence-generating grids. Stagnation-region heat transfer augmentation increased with decreasing length scale but an optimum scale was not found. A correlation was developed that fit heat transfer data for isotropic turbulence to within {+-}4 percent but did not predict data for anisotropic turbulence. Stagnation heat transfer augmentation caused by turbulence was unaffected by the velocity gradient. The data of other researchers compared well with the correlation. A method of predicting heat transfer downstream of the stagnation point was developed. 28 refs., 12 ...
This experiment investigated the effects of free-stream turbulence intensity, length scale, Reynolds number, and leading-edge velocity gradient on stagnation-region heat transfer. Heat transfer was measured in the stagnation region of four models with elliptical leading edges downstream of five turbulence-generating grids. Stagnation-region heat transfer augmentation increased with decreasing length scale but an optimum scale was not found. A correlation was developed that fit heat transfer data for isotropic turbulence to within #+-#4 percent but did not predict data for anisotropic turbulence. Stagnation heat transfer augmentation caused by turbulence was unaffected by the velocity gradient. The data of other researchers compared well with the correlation. A method of predicting heat transfer downstream of the stagnation point was developed. 28 refs., 12 ...
Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...
Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...
A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region.
(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict heat-transfer rates on the basis of boiling ...
An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate to capital cost and reference state temperature is developed. (author)
A metal matrix is inserted into a phase-change material to enhance the heat transfer during phase-change processes. The metal matrix tends to act like a heat transfer fin from the heated or cooled surface and to increase the effective thermal conductivity of the phase-change fluid. The scope of the study involves numerically modeling the heat transfer to and from constant-temperature cylindrical tubes surrounded by water during the freezing and melting processes. Comparisons of heat transfer with and without the metal matrix are made, with different porosities and densities of the metal matrix being examined. The results of this study are discussed in terms of the effectiveness of the metal matrix as a heat transfer enhancement device.
A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region. (author).
Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the effects of combustion chamber specifications and swirl ratios on the heat release and transient heat transfer characteristics. Heat rejection was examined on the basis of heat release calculations using cylinder pressure time histories. Transient surface temperature data obtained from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. The results showed good agreement with the heat rejection calculated from cylinder pressure data and that transient heat flux in a piston cavity was reduced with the larger cavity diameter and a higher swirl ratio. On the other hand, a transient heat flux in a piston head was not changed by the cavity ...
Nuclear energy plays an important role in electricity generation, producing 16% of the world's electricity at the beginning of 1999. It has proven to be safe, reliable, economical and has only a minimal impact on the environment. Most of the world's energy consumption, however, is in the form of heat. The market potential for nuclear heat was recognized early. Some of the first reactors were used for heat supply, e.g. Calder Hall (United Kingdom), Obninsk (Russian Federation), and Agesta (Sweden). Now, over 60 reactors are supplying heat for district heating, industrial processes and seawater desalination. But the nuclear option could be better deployed if it would provide a larger share of the heat market. In particular, seawater desalination using nuclear heat is of increasing interest to some IAEA Member States. In consideration of the ...
A method is described of controlling an anodic protection system in a heat exchanger comprising: (a) installing at least one cathode within the heat exchanger, at least one cathode being aligned with the longitudinal axis of the heat exchanger and extending substantially along the length of the heat exchanger; (b) installing a first reference electrode within and at one end of the heat exchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heat exchanger; (c) measuring the electrical potential of the heat exchanger with the first reference electrode; (d) operating the first controller in response to measurements made by the first reference electrode to change the output of the power supply; (e) ...
The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter Brennwerttechnik ihre Kosten senken und einen ...
Compact heat exchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heat exchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heat exchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 mm) using refrigerant 12 (R-12). As with the circular tube ...
The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat exchanger and overall heat transfer coefficient are quantified under frost conditions as ...
The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. The constant heat flux as thermal boundary condition was adopted in the thermally developed region. The present analytical results show the heat transfer enhancement over those of a shear rate-independent thermal conductivity fluid. The heat transfer coefficient ratio (h/h{sub 0}) linearly increase with the non-dimensional average velocity difference which is the product of the shear rate-dependence of the thermal conductivity and wall-shear rate.
This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.
This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.
This study shows that the physical conditions necessary for thermal waves to materialize in Dual-Phase-Lagging porous media conduction are not attainable in a porous slab subject to a combination of constant heat flux and temperature (Neumann and Dirichlet) boundary conditions. It is demonstrated that the approximate equivalence between Dual-Phase-Lagging (DuPhlag) heat conduction model and the Fourier heat conduction in porous media subject to Lack of Local Thermal Equilibrium (La Lotheq) that suggested the possibility of thermal oscillations and resonance reveals a condition that cannot be fulfilled because of physical constraints. (author)
A comprehensive presentation is made of state-of-the-art configurations and design methodologies for heat transfer devices applicable to industrial processes, automotive systems, air conditioning/refrigeration, cryogenics, and petrochemicals refining. Attention is given to topics in heat exchanger mechanical design, single-phase convection processes, thermal design, two-phase exchanger thermal design, heat-transfer augmentation, and rheological effects. Computerized analysis and design methodologies are presented for the range of heat transfer systems, as well as advanced methods for optimization and performance projection.
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.
The SmartStore model was developed to determine the optimum design of borehole heat stores as a function of different design parameters. The optimum design is defined as the design that achieves the storage task with a minimum annual storage cost. The annual storage cost is the sum of annual costs of investment, operation, maintenance and heat loss. The PC-model has a user-friendly lay-out and gives a fast pre-design of borehole heat stores. In this article the model is briefly described. It is also shown that the technical design of the store is influenced by varying technical properties of the storage volume, but also by the cost of heat. (orig.)
The concentric circular annular duct is a common geometry in many fluid flow and heat transfer devices. For the purpose of heat transfer augmentation, fins are often employed in the annular region, and such finned ducts find wide application in compact heat exchangers (5, 6). The analysis of flow and heat transfer in this geometry is, therefore, quite important from an engineering standpoint. For fully developed conditions, the problem has already been analyzed (7-10). However, no results are available for the developing flow in the entrance region. It is with this latter problem that the present paper is concerned.
This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)
This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating ...
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e l'impiego di immagini provenienti da altre ...
The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space ...
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating ...
Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the transient heat transfer characteristics. Transient temperature data from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. Transient surface temperature was measured using the thin film thermocouples. At first, the transient heat flux rates calculated from the analysis method used in this paper were compared with the results from FEM. The results showed good agreement. Using this analysis method, the transient heat flux rates were calculated. The tests were performed at 1200 rpm with constant air flow. The parameters that were varied included the fuel rate and injection timing. Based on these results, the present paper discusses the mechanism of heat rejection in a direct-injection diesel engine. 8 ...
Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds ...
Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the ...
High-performance heat transfer augmentation methods applicable in the forced convection field of heat exchangers include a method which requires no external drive means, such as the insertion of a turbulence augmentation object into the flow passage and the use of a wave-shaped flow passage, but disturbs the main stream of flow to raise the heat transportation effect thereby to augment heat transfer in the flow passage. The heat transfer characteristics and thermal performance ratio achieved when sinusoidal-shape plates are inserted instead of augmentation objects, such as cylinders, with a high shape-induced resistance were studied. As a result, the relationship between the resistance coefficient, average Nusselt number, heat transfer coefficient, and pitch was clarified. It has been revealed that the use of eddies with a large gap flow and recirculation area ...
Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen Verbreitungsschub. In dem durch Heiz- und Kuehlbedarf charakterisierten Umfeld kann sie Ihre Vorteile voll nutzen. Fuer Deutschland kommt ...
In the wide range from brown coal to anthracite, an investigation was made of effects of heat treatment on physical/chemical properties and of coal rank dependence. For the experiment, 12 kinds of coal samples were used, and for heat treatment, the fluidized bed heated by the electric furnace and the infrared-ray gold image furnace were used. To examine characteristics of the heat-treated coal char, conducted were oxygen gasification, TPD measurement, XRD measurement, alkali metal measurement, and pore distribution measurement. The following were obtained from the experiment. The gasification reaction rate of the char heat-treated in the temperature range between 900{degree}C to 1700{degree}C decreases with a rise of the temperature of heat treatment, and the degree of decrease in the rate depends on coal rank. The order of gasification rate between coal ranks ...
The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is modeled to meet the requirements of the 10 ...
Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ...
The flow distribution through a plate-fin heat exchanger is studied by using a computational fluid dynamics (CFD) code, FLUENT. The flow distribution through any heat exchanger affects its performance. In designing a heat exchanger, it is assumed that the fluid is uniformly distributed through the heat exchanger core. In practice, however, it is impossible to distribute fluid uniformly, because of an improper inlet configuration, imperfect design, and a complex heat transfer process. The CFD simulation of the flow distribution in the header of a conventional plate-fin heat exchanger is presented. It is found that the flow maldistribution is very serious in the y-direction of the header. A modified header is proposed and simulated using CFD. The modified header configuration has a more uniform flow distribution than the conventional header configuration. Hence, ...
An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained explains that no ...
A method of Kelvin-day function for climatic solar heating design is presented. The long term temperature distribution is used to find the solar fraction for building heating. A solar heating system is considered to provide heat needed up to an auxiliary heater cut-in temperature which is determined by both heat gain of solar heating system and overall heat loss coefficient of the building. The amount of auxiliary heat needed is calculated from a Kelvin-day value at this cut-in temperature. The cut-in temperature will change from different solar heating system designs, and the Kelvin-day value at this cut-in temperature will be varied. By using the numerical curve-fitting method, the Kelvin-day value at any temperature base can be expressed into a second order algebraic equation, thus, the whole data ...
Three systems for the heat supply in the built environment have been compared for the costs, the energy consumption and emissions of CO{sub 2}, NO{sub x} and SO{sub 2}. The heating systems compared are based on central heating boilers, district heating systems in combination with combined steam and gas turbine cycles, and heating by means of several gas engines. From the results it appears that the boilers demand the lowest investments. The district heating systems are more expensive. Both heating systems, however, show considerable savings of energy (55 to 70%). The exploitation costs depend strongly on the fuel price scenarios used and the assumptions with regard to interest and inflation. The emissions of CO{sub 2} are also considerably lower for both combined heat and power generating systems. The use of gas engines ...
Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in ...
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of ...
A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. ...
The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)
A solar thermal powered aircraft powered by heat energy from the sun. A heat engine, such as a Stirling engine, is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller. The heat engine has a thermal battery in thermal contact with it so that heat is supplied from the thermal battery. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the ...
The patent describes a method for repairing leakage-causing cracks and fissures in a cryogenic heat exchanger. It comprises: reducing the interior pressure of the heat exchanger to a level which does not exceed the external pressure upon the hear exchanger while maintaining the temperature of the heat exchanger at a low level relative to the ambient external temperature; applying a curable liquid filler composition to the surface of the heat exchanger proximal the leakage site for seepage into the cracks and fissures located at the leakage. The composition upon a relatively short period of cure at low temperature forming a solid material which fills the cracks and fissures; curing the filler composition; and, applying a sealant composition to the surface of the heat exchanger at the filled leakage site. The sealant composition having long-term sealing performance under cyrogenic ...
Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction. (author)
RODbaffle heat exchanger is a kind of shell-and-tube heat exchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat transfer on shellside of the RODbaffle ...
This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee ...
An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% ...
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters ...
The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).
Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including ...
Heat transfer augmentation based on the process intensification concept in heat exchangers and thermal reactors has received much attention in recent years, mainly due to energy efficiency and environmental considerations. The concept consists of the development of novel apparatuses and techniques that, compared to those commonly used today, are expected to bring dramatic improvements in manufacturing and processing, substantially decreasing equipment size, energy consumption, and ultimately resulting in cheaper, sustainable technologies. The objective of this paper was to investigate the heat transfer characteristics of tubular thermal reactor using static mixing technology. Glycerin and water were used as the test fluids and water was used as the heating source. The results for heat transfer rate were strongly influenced by tube geometry and flow conditions.
This paper describes the heat transfer augmentation and the flow situation around a single spacer (a cylindrical rod) on the heated surface of a parallel plate duct in order to examine basically the effects of the spacer in the fuel elements of a high temperature gas-cooled reactor. The ends of the cylindrical rod contact the upper and lower planes. A thermosensitive liquid crystal film is used to indicate the effective area for the heat transfer. The mean Nusselt number, which is estimated within the optional distance from the spacer to the downstream direction, peaks at a dimensionless distance of X/D = 1-3, and after that decreases gradually with the flow direction. The manner in which heat transfer corresponds to the flow situation is also examined. The horseshoe vortex, produced around the spacer, affects the wake and contributes to the increase of the local heat transfer. ...
A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.
Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)
Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)
The lower condition factors for two catfish species in water heated by effluents from APCo's Glen Lyn, Virginia plant as compared to control areas probably is not due to lack of food as evidenced by macroinvertebrate sampling and the fact that only 4.3 percent of the catfish stomachs were empty. Results suggested that young-of-the-year channel catfish were nonselectively eating food organisms present at both control and heated stations. The difference between stomach contents of flatheat catfish from the heated site and fauna available at that site indicated that fish were either moving out of the heated area to feed or were selectively feeding on organisms (particularly mayflies) which were in the substrate or drifted into the heated area. Stomach contents of the two species and distribution and abundance of the macroinvertebrate benthos community are detailed.
The report presents the results of experimental studies conducted to provide a description of the conditions which lead to the occurrence of critical heat flux (CHF), in Combustion Engineering (C-E) fuel assemblies using the C-E standard spacer grid. A CHF correlation is presented which is based on CHF data obtained in tests with electrically heated rod bundles representative of the C-E 14 x 14 and 16 x 16 array fuel assemblies. The results reported are for a uniform axial heat flux distribution. The experiments were conducted in the Medium Pressure Heat Transfer Flow Loop at the Chemical Engineering Research Laboratories at Columbia University.
Forced convection boiling of subcooled water was performed in a horizontal rectangular channel with heated surface on the bottom. The experiment was conducted for heating surfaces, 10 mm, 20 mm and 40mm in length. Microbubble Emission Boiling, MEB, was observed in subcooled transition boiling and easy to be generated for the shorter heating surfaces. In higher flow velocity of subcooled water, MEB was generated at even lower subcooling. Stormy MEB was observed at both the higher subcooling and the higher flow velocity of water. In the stormy MEB, the heat flux rose up rapidly above CHF (Critical Heat Flux) with larger acoustic noise and vibration. (author)
Using a quasi-static approach valid for Stefan numbers less than one, we derive approximate equations governing the movement of a phase change front for materials which generate internal heat. These models are applied for both constant surface temperature and constant surface heat flux boundary conditions, in cylindrical, spherical, plane wall and semi-infinite geometries. Exact solutions with the constant surface temperature condition are obtained for the steady-state solidification thickness using the cylinder, sphere, and plane wall geometries which show that the thickness depends on the inverse square root of the internal heat generation. Under constant surface heat flux conditions, closed form equations can be obtained for the three geometries. In the case of the semi-infinite wall, we show that for constant temperature and constant heat flux out of the wall conditions, the ...
In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...
The analysis for the WITCH/LINER experiments was performed to investigate the heat transfer characteristics between the gas-agitated steel melt and the vertical surface. The applicability of heat transfer correlations for a gas-agitated fluid system was examined through the numerical analysis of the one-dimensional heat conduction taking into account the crust formation due to the solidification of the steel melt. The heat transfer correlation developed by Konsetov was modified for the application to fluids with low Prandtl number. The constant in the modified correlation was empirically found mainly through the comparison between the analysis and the experiments under conditions that a churn-turbulent two-phase flow regime was anticipated to form. The modified Konsetov correlation could predict the heat transfer characteristics observed through the experiments in an acceptable ...
This paper describes the heat transfer augmentation and flow situation around a single spacer (a circular cylinder) on a heated surface in a parallel plate duct in order to examine basically the effects of the spacer in the fuel elements of a High Temperature Gas-cooled Reactor. A thermosensitive liquid crystal film was used to clarify the effective region of the heat transfer. The mean Nusselt number, which was estimated within arbitrary distance from the spacer to the downstream direction, took a peak at the dimensionless distance X/D = 1 #approx# 3, and after that decreased gradually with flow direction. How heat transfer corresponds to the flow situation is also examined. The horseshoe vortex, produced around the spacer, affects the wake and contributes to the increase of the local heat transfer. (author).
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer ...
This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both the high temperature and low temperature ...
The heat transfer augmentation effect by the unsteady heat conduction between the particles and heat transfer surface is one of the main factors, causing the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. By separating and evaluating that effect, material influence on it was studied of particles and heat transfer surface, together with change by the jet flow condition. That effect enlarged with enlarging in heat capacity, multiplied by the heat conduction coefficient, of both the particles and heat transfer surface, and if both of them were constant in material combination, was dominated by the contact frequency of particles per unit time. Therefore in case of lading solid particles, equal in weight, that effect enlarges with diminishing in particle diameter. Such a ...
A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term ...
Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system installed in a newly drilled heat exchange well of 100m deep. ...
Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, measurements have ...
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert auf die Bestimmung ...
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...
The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did not differ from that observed by 99mTc-sulfur colloid scan or ...
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...
PPARgamma agonists have been proposed to exert more than metabolic benefits, particularly by anti-inflammatory mechanisms. We hypothesized that pioglitazone might modulate inflammatory and vascular responses to lipopolysaccharide (LPS). In a placebo-controlled parallel-group study in 18 healthy male subjects, the E. coli endotoxin model of inflammation (20 IU/kg i. v.) was employed to test the effect of 60 mg pioglitazone over nine days on inflammatory cytokines. Macrovascular function and microvascular blood flow were assessed by brachial artery ultrasound and retinal blood flow parameters, respectively. Pioglitazone increased brachial artery diameter by 5.6% but had no effect on other outcome parameters under resting conditions. LPS increased cytokine levels to peak concentrations of 91.3+/-22.5 ng/ml (IL-6), 261.4+/-60.0 ng/ml (TNFalpha), and 524.5+/-15.3 ng/ml (VCAM-1). The endotoxin caused microvascular vasodilation and increased retinal white blood cell flux, ...
Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this ...
As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen ...
Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of ...
We wanted to evaluate the correlation of mild renal pelvic dilatation (RPD) that is observed to be less than 10 mm on ultrasound (US) with urinary tract infection (UTI) and vesicoureteral reflux (VUR) in neonates. We reviewed 137 kidneys of 107 neonates who had RPD less than 10 mm on US. All the kidneys were divided into two groups: Group I (RPD <= 5.0 mm) and Group II (RPD > 5.0 mm), and we statistically analyzed the RPD change according to UTI and VUR. Seven neonates had VUR (5.1%), and there was no statistical significance between Group I (6 neonates, 5.6%) and Group II (1 neonate, 3.3%). Thirty seven cases (27%) had UTI and there was no statistical significance between Group I (30 cases, 28.0%) and Group II (7 cases, 23.3%). The RPD did not change in 81.8% of the cases, it increased in 4.4% of the cases and it decreased in 13.9% of the cases on follow up US. The incidence of VUR and UTI were not different according to the change of RPD. There were ...
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and ...
The use of an extraction of the heme pigments hemoglobin and myoglobin as a test for the heat exposure of back bacon was investigated by treating back bacon at varying temperatures of 50-70 degrees...Full Text Available
Related to other research on the effectiveness of flow boiling heat transfer augmentation using various types of turbulators this investigation comprises a definitive study of the effect of large discrete roughness elements on heat transfer over the entir...
The effect of velocity gradient on stagnation region heat transfer augmentation by free stream turbulence was investigated. Heat transfer was measured in the stagnation region of four models with elliptical leading edges with ratios of major to minor axes of 1:1, 1.5:1, 2.25:1, and 3:1. Four geometrically similar, square bar, square mesh, biplane grids were used to generate free stream turbulence with different intensities and length. Heat transfer measurements were made for the following ranges of parameters: Reynolds number, based on leading edge diameter, 37,000 to 228,000; dimensionless leading edge velocity gradient, 1.20 to 1.80; turbulence intensity, 1.1 to 15.9%; and length scale to leading edge diameter ratio, 0.05 to 0.30. Stagnation point heat transfer augmentation by free stream turbulence can be predicted using a modified version of a previously developed correlation for a circular leading ...
Carbenoxolone (CBX) is a semisynthetic derivative of the licorice root substance glycyrrhizinic acid and has been previously reported to induce only heat shock protein 70 [Hsp70, HSPA1A (the systematic...Full Text Available
A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular ...
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As ...
The Subseabed Disposal Program has recently completed a 30-day, 0.286-scale laboratory simulation of an In Situ Heat Transfer Experiment (ISHTE), scheduled for eventual deployment in the deep ocean 600 nautical miles north of Hawaii. 10 figures.
The Subseabed Disposal Program has recently completed a 30-day, 0.286-scale laboratory simulation of an In Situ Heat Transfer Experiment (ISHTE), scheduled for eventual deployment in the deep ocean 600 nautical miles north of Hawaii. 10 figures.
The presence of highly heat-resistant spores of Bacillus sporothermodurans in ultrahigh-temperature or sterilized consumer milk has emerged as an important item in the dairy industry....Full Text Available
The possibility of rapid heat treatment (RHT) application to titanium castings has been studied. It was shown that such treatment provides a significant improvement of intragrain structure and mechanical properties of cast ({alpha}+{beta})-titanium alloys. ((orig.))
An approach to the calculation of the quantity of heat consumed in the process of coal formation is presented. The variability of this parameter in a coalification series is analyzed using coals from the Kuznetsk and Tunguska Basins as an example.
Heat transfer enhancement in a heat exchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat transfer. The ...
Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...
The heat storage material consists of a mixture of oleic and stearic acids in which stearic acid is present to the extent of 30 percent to 90 percent by weight. In addition to this binary system, the invention is also directed to a ternary system in which diphenyl ether is present along with the stearic and oleic acids.
In the interests of fuel economy in motor vehicles, this article discusses the importance of waste heat recovery and then goes on the explore options such as hybrid electric cars, thermal engines with low loss platforms, pure electric vehicles and fuel cell vehicles. (UK)
The methodology of constructing Nomographs for easy determination of heat loss due to incomplete combustion for a particular fuel has been presented in this article. The authors have worked out the Nomograph for jute stick and paddy straw.
The Heat Cycle Research Facility (HCRF) is an experimental binary-cycle facility used to investigate different concepts and/or components for generating electrical power from a geothermal resource. This report briefly desc
Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.
The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)
An experimental investigation of heat transfer characteristics for various configurations of air jets impinging on the leading edge inner surface of a gas turbine blade wall is presented. Three configurations were investigated, namely a slot jet, a round ...
In the utilization of the thermal energy by ocean temperature difference and factory waste heat, the high performance heating surfaces in pipes from which scale can be removed are required. As the method of removing scale, the method using sponge balls seems most suitable, but for applying this method, as the form of the protrusions attached to the inner surfaces of pipes, smooth circular are form is desirable. The promotion of heat transfer with the rows of circular arc protrusions like this is strongly related to the mode of flow and such structure as separation, recirculation flow, readhesion and turbulent energy generation. In this study, as the basic research to optimize the heating surface with the rows of smooth protrusions, the flow characteristics and the heat transfer characteristics including the turbulent structure of the wake of protrusions were experimentally ...
An experimental rig was set up to study the performance of a thermal storage unit using stearic acid as the heat storage medium. The unit mainly consists of an electrical heating rod and an outer tube, and the space between is an annulus that is filled with stearic acid. The thermal performance of the unit is measured, and the heat transfer characteristics of the melting processes of stearic acid are studied under different heat flux conditions to determine the influence of heat flux on the melting processes. A new type of fin is designed and fixed to the electrical heating rod to enhance the thermal response of the stearic acid. The experimental results show that the fin can improve the heat transfer of the melting process of the thermal storage unit greatly. The equivalent thermal conductivity of the PCM can be augmented by a factor up to ...
An experimental rig was set up to study the performance of a thermal storage unit using stearic acid as the heat storage medium. The unit mainly consists of an electrical heating rod and an outer tube, and the space between is an annulus that is filled with stearic acid. The thermal performance of the unit is measured, and the heat transfer characteristics of the melting processes of stearic acid are studied under different heat flux conditions to determine the influence of heat flux on the melting processes. A new type of fin is designed and fixed to the electrical heating rod to enhance the thermal response of the stearic acid. The experimental results show that the fin can improve the heat transfer of the melting process of the thermal storage unit greatly. The equivalent thermal conductivity of the PCM can be augmented by a factor up to ...
Scraped-surface heat transfer augmentation is proposed as a possible technique for use in improved air-cooling designs. Although it has been in common use with liquids, the technique has apparently never been used with gases. An experimental investigation...
Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar assisted ground-source heat pump (GSHP) unit and the overall ...
Hoogenstraaten's heating rate method has generally been considered as a reliable method for determining thermoluminescence trapping parameters of first order glow peaks. However, experience has shown that in some cases the deviation between the heating rate method and glow curve fitting method can be quite significant (considering only the linear part of the heating rate plot, of course). In this study it is shown that one of the main reasons for this deviation can be a systematic increase of a temperature lag between the measured and real temperature of the sample with increasing heating rate. It appears that this systematic increase of the temperature lag affects the method in the range of low heating rates (linear part of the heating rates plots) more than has been previously realised. The effect of the temperature lag on Hoogenstraaten's ...
Hoogenstraaten's heating rate method has generally been considered as a reliable method for determining thermoluminescence trapping parameters of first order glow peaks. However, experience has shown that in some cases the deviation between the heating rate method and glow curve fitting method can be quite significant (considering only the linear part of the heating rate plot, of course). In this study it is shown that one of the main reasons for this deviation can be a systematic increase of a temperature lag between the measured and real temperature of the sample with increasing heating rate. It appears that this systematic increase of the temperature lag affects the method in the range of low heating rates (linear part of the heating rates plots) more than has been previously realised. The effect of the temperature lag on Hoogenstraaten's ...
This research has been proceeded over the potential core region (H/B=2) of two-dimensional impinging air jet system, in which square rods(width of 6 mm) has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in cases of the clearance from rods to heating surface (C = 1, 2, 4, 6 mm) and the pitch between each rods(P = 30, 40, 50 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C = 1 mm, in case clearance changed, and there was no serious difference in the effect of heat transfer augmentation in the case of pitch of rods changed. (author) 11 refs. 12 figs.
The mechanical properties of laminated window profiles manufactured using two types of adhesives were determined. The objective of this study is to evaluate the effects of heat treatment on some mechanical...Full Text Available
This progress report presents a detailed description of the background, technology and application, and Statement of Work for the development of a coal-fired pulse combustor for residential space heating.
Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.
The present investigation represents the initial phase of a comprehensive experimental program designed to study the potential for increasing the heat transfer per unit pressure drop in a ribbed duct by positioning vortex generators at key locations in the flow. In particular, the present investigation consists of a rib positioned at the inlet to a rectangular test section with uniform heating at its bottom wall. Local and average Nusselt number results are obtained for a circular rod positioned either immediately above or just downstream of the rib.
A conceptual design of a solar retrofit to US Gypsum's plant at Sweetwater, Texas, has been developed which provides heated air to a large gypsum board drying kiln that is currently under construction. The solar heated air displaces natural gas normally used for the process heat. The solar retrofit is composed of a tower focus collector with a cavity receiver which uses air as the heat transfer fluid. An executive summary of the conceptual design, system performance, economics, and development plan is presented. (WHK)
Ultrasonic enhancement of heat transfer on a narrow surface was measured by changing the width of the surface from 8 to 0.1 mm. Ultrasonic power of 600 W with a frequency of 40 kHz was used. Heat transfer on the narrow surface without ultrasonic vibration was correlated by the experimental equation for a thin wire. The cavitation intensity was measured by the cavitation erosion loss of an aluminum foil of 15 [mu]m thickness. The effects of acoustic streaming and cavitation were separated by this measurement. Heat transfer by acoustic streaming was predicted through forced convection. Enhancement by cavitation was explained by the turbulence thermal conductivity of the microjets.
In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
An extension of the Hodgkin-Huxley mathematical model for the propagation of nerve signal which takes into account dynamical heat transfer in biological tissue is derived and fine tuned with existing experimental data. The medium is heated by Joule's effect associated with action potential propagation, leading to characteristic thermal patterns in association with spiral and scroll waves. The introduction of heat transfer-necessary on physical grounds-provides a novel way to directly observe the movement, regular or chaotic, of the tip of spiral waves in numerical simulations and possibly in experiments regarding different biological excitable media.
Innovative new ideas for the construction of homes are described. A thermal energy storage system fireplace and a geothermal heat pump for homes are described.
The thermal evolution predicted by current models of the superfluid-crust interaction is noted to differ substantially from the thermal evolution predicted by models without internal heating as well as previous models of heating. Heating rates approaching the maximum predicted by current models enhance the photon luminosity of the star in the neutrino cooling era, and dramatically alter the thermal evolution in the photon cooling era. Standard cooling models are consistent with current pulsar temperature estimates and upper limits, except those for the Vela pulsar, which are lower than predicted. 77 refs.
The heat transfer characteristics of a newly developed transport and storage cask for vitrified heat-producing radioactive waste from reprocessing are described. The theoretical layout of the cask was tested by measurements on a prototype cask of the scale 1:1. These measurements confirmed the theoretical thermodynamic layout data. They can be described by the function Nu=CxRa"m, with the constant C, but not the constant m, differing for a vertical and a horizontal position of the cask. The measured velocity and temperature profiles of the cask were verified with an existing code for the calculation of heat transfer from finned horizontal cylinders by natural convection. (orig.).
Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.
Direct electric heating by passing an electrical current directly through a bed of adsorbent may prove to be an efficient means of regenerating activated charcoal in continuous and batch adsorption processes. Obvious advantages of this type of regeneration are its almost complete lack of inertia, which makes it possible to reduce the number and dimensions of the adsorbers, and its highly efficient use of energy due to the small number of steps in the conversion of the energy, as well as the reduction of heat losses involved in warming the structure and making up for losses to the surroundings. The authors consider the kinetics of direct electric heating of a stationary bed of activated charcoal not containing adsorbed substances.
In this paper it is described how a martensitic steel sheet with tensile strength of 1400 MPa is heat treated locally. The sheet is then formed in the heat treated regions in a way that would be impossible with the untreated material. Mechanical properties and forming limit diagrams of the heat treated material are determined and the forming operations are simulated, which shows that the method can be used by designers. Although the method has been known for decades, it remains to be industrialised and the work presented here is to be seen as a contribution to this development. (orig.)
An improved hybrid solar/combustion powered receiver of the type having an insulated housing with a front end and a rear end, a heat exchanger positioned adjacent the rear housing end for extracting heat energy out of the receiver, the insulated housing surrounding the heat exchanger and forming a receiver cavity, the housing also including an aperature having an aperture axis, the aperture located in the front housing end for admitting solar radiation to the cavity to impinge upon the heat exchanger, and a plurality of gas burners to provide combustion gases within the receiver.
Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.
Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.
Isobaric molar heat capacities of powder and microsphere form of Li2TiO3 (s) and powder form of LiAlO2 (s) and Li2ZrO3 (s) were measured using a heat flux type differential scanning calorimeter in the temperature range 320 - 870 K. Specific heat capacities of LiAlO2 (s) was found to be much larger compared to those of Li2TiO3 (s) and Li2ZrO3 (s). (author)
Low-dust flue gases can be washed efficiently of SO/sub 2/, and the flue gas heat can be utilized. The residual heat fraction still required by the process is characterized by a temperature of 15/sup 0/K above the temperature of the purified flue gas. Marketable crystalline ammonium sulfate is produced. The high efficiency and low heat consumption are achieved by combining all process stages in a single, fully integrated cycle process free of heat and materials losses. The process is characterized by high efficiency, low investment and operating costs, recovery of thermal energy, and production of an ammonium sulfate fertilizer.
Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)
Currentless plasma in Uragan-3M (U-3M) is produced and heated by absorption of RF power in the region of Alfven waves (AW). The process of plasma heating was explained in (2) as a result of Cherenkov absorption of energy of the fast (EM) and slow (kinetic Alfven) waves by electrons and turbulent ion heating due to excitation of short wave ion Bernstein waves (IBW). In this report we present results of studies of plasma density fluctuations showing existence of a narrow bands near the frequencies of ? ? n?ci (n=1,2,3).
The microbial safety of foods cooked in microwave ovens was investigated. The mechanisms of microwave destruction of microorganisms were examined. Effects of time and temperature on microorganisms in different food systems were described. Studies showed that: microwave heating of food is more ''''food dependent'' than conventional heating; recommended microwave treatment time for some foods may not destroy high levels of bacteria; use of microwaves in combination with conventional heating methods results in more uniform heating of foods and destruction of bacteria; and microwaves exert different killing effects on individual bacterial species. (78 references, 2 tables)
In the present study, a subcooled boiling loop with an annular flow on the electrically heated rod was used to make an experimental approach to investigate the effects of induced instability by the subcooled boiling on vibration of the rod in different subcooled conditions. The results show the intensive subcooled-boiling-induced vibration (SBIV) which is highly depend on dynamic force generated by fast vapor bubbles growth and collapse whilst they still attach to, or slide along, the heating surface at high loading heat fluxes. These behaviors were strongly influenced by the conditions of subcooling temperature, flow rate and linear power density. (author)
Unsteady impinging jets are systematically controlled with respect to their time dependence in order to investigate the influence of unsteadiness on the heat transfer performance. This is achieved by a special mass flow control device, which allows almost arbitrary shapes of unsteadiness to be imposed onto the impinging jet. Three different standard signals (sinusoidal, triangular, rectangular) and two specially designed signals are applied and their influence on heat transfer is determined in terms of an enhancement factor. Heat transfer augmentation up to 30% was found and could be physically explained with the help of PIV and hot-wire measurements of the flow field.
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
Compact heat exchangers are being increasingly considered for condensation applications in the process, cryogenic, aerospace, power and refrigeration industries. In this paper, different configurations available for condensation applications are analyzed and the current state-of-the-knowledge for the design of compact condensers is evaluated. The key technical issues for the design and development of compact heat exchangers for condensation applications are analyzed and major advantages are identified. The experimental data and performance prediction methods reported in the literature are analyzed to evaluate the present design capabilities for different compact heat-exchanger configurations. The design flexibility is evaluated for the development of new condensation applications, including integration with other process equipment.
Heat transfer augmentation has developed into a major specialty area in heat transfer research and development. A bibliography of world literature on augmentation is presented. The literature is classified into passive augmentation techniques, which require no external power, and active techniques, which do require external power. The fourteen techniques are grouped in terms of their application to the various modes of heat transfer. Mass transfer is included for completeness. Key words are included with each citation for technique/mode identification. The total number of publications cited is 1,967, including 75 surveys of various techniques and 42 papers on performance evaluation of passive techniques. Patents are not included as they will be the subject of a future topical report.
The production of process heat for agriculture and industry is one of the applications of solar energy which is very close to economic competitivity. Solar collectors can be produced at a reasonable cost by existing industries and are used optimally through applications which present a good time correlation between energy needs and the possible production of solar heat. This article studies heat consumption in industrial and agricultural sectors, gives hints on collectors choices, rates the different projects by simulation taking into account the nature of agricultural and industrial activities and the geographical location of the projects, examines when the equipment first competes according to hypotheses made on the various energy and collectors cost.
This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.
This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.
The basic studies of this report, had been done with a wind tunnel. Model similarity with typical atmospheric situations - such as an urban heat island - had to exist. Sufficient heat is needed to generate turbulent convection at the ground. By omitting the Boussinesq-approximation proper similarity parameters could be found to present the results in a dimensionless form. Also the effect of a cross circulation was investigated as well as the question at which conditions the convection is no longer able to overcome the longitudinal momentum of the wind. (KW).
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
When the vehicle-treated, sham-operated mice underwent heat stress, the fraction survival and core temperature at +4 h of body heating were found to be 5 of 15 and 34.4°C ± 0.3°C,...Full Text Available
The influence of heat treatment on the structure, mechanical properties and fracture peculiarities of high-strength (#alpha#+#beta#)-titanium alloy VT22 has been studied. It is ascertained that thermal cycling and subsequent high-temperature aging permit to reduce considerably crack growth rate. Thermal cycling is realized in the following mode: heating in #beta#-region, cooling and allowance in (#alpha#+#beta#)-region, heating in #beta#-region.
The utilization of electrically heated rods for the simulation of nuclear fuel rods represents an universally adopted method by the nuclear industry to study thermalhydraulic problems. The present work represents the development of a method to obtain the time variation of the electric linear power necessary to simulate a given nuclear power transient in order to yield the same temperature and heat flux conditions in the surface of the electrical heater that would be obtained by the nuclear fuel rod. (Author).
This report contains a set of nomographs which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.
A set of nomographs is presented which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.
A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)
The advantages of radiofrequency and microwaves, such as volumetric heating, rapid and selective heating, compactness of equipment and ease of operation, offer sound economic alternative heating techniques. This article discusses dielectric loss, its quantification, and how it is put to effective use, including the use of applicators. Brief recommendations are presented for whether to select radio frequency or microwaves for a particular application. Uses of radiofrequency and microwaves in the industrial, domestic and medical sectors are described.
By using a laser and maser in tandem, it is possible to obtain laser action in the hot exhaust gases involved in heat engine operation. Such a "quantum afterburner" involves the internal quantum states of working gas atoms or molecules as well as the techniques of cavity quantum electrodynamics and is therefore in the domain of quantum thermodynamics. As an example, it is shown that Otto cycle engine performance can be improved beyond that of the "ideal" Otto heat engine.
This book is organized under the following headings: Electrohydrodynamic heat transfer augmentation; Forced convection augmentation and heat transfer control; Turbulent heat transfer; Thermal problems in the environment; Energy conversion systems; Measurement, visualization, and imaging; Thermal problems in space technology; and Thermal properties.
A comparison of nucleation and crystallization of Li{sub 2}O{sm_bullet}2SiO{sub 2} between microwave and conventional heating was investigated. Standard stereological techniques were used to evaluate the results. Nucleation and crystallization behaviors during microwave heating appeared different from conventional heating. Work is in progress to better understand the effects of microwaves on nucleation and crystallization in glass.
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
This paper presents a theoretical study of heat transfer from magneto-rheological fluid (MRF) dampers. A lumped system model is developed which is capable of predicting the temperature rise for any size MRF damper. As a case study example, finned and unfinned dampers are compared for automotive-size MRF dampers. The results demonstrate that heat transfer from these devices can be enhanced considerably with the use of fins.
This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)
A passive heat exchange enhancement structure which operates by free convection includes a flat mounting portion having a plurality of integral fins bent outwardly from one side edge thereof. The mounting portion is securable around a stovepipe, to a flat surface or the like for transferring heat from the pipe through the fins to the surrounding air by rotation-enhanced free convection.
Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.
As part of our ongoing research to provide quality improvements to heating oil, Mobil Oil together with Santa Fuel, Inc., conducted a field trial to investigate the performance of a new premium heating oil. This premium heating oil contains an additive system designed to minimize sludge related problems in the fuel delivery system of residential home heating systems. The additive used was similar to others reported at this and earlier BNL conferences, but was further developed to enhance its performance in oil heat systems. The premium heating oil was bulk additized and delivered to a subset of the customer base. Fuel related, unscheduled service calls were monitored in this test area, as well as in a similar baseline area that did not receive the premium heating oil. Overall, the premium fuel provided a 45% reduction in the occurrence of ...
This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).
This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).
Effect of cooling rates within the wide range (0.003-45 grad/s) on the complex of mechanical properties of (#alpha#-#beta#)-titanium alloy VT3-1 is studied in the process of heat treatment. Cooling conditions of semifinished product made of this alloy with a different structure providing optimum combination of strength, ductility fracture toughness, heat resistance, and endurance are determined.
The mainly nonstationary operation of a solar-heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
The mainly instationary operation of a solar heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
One of several methods to build YSZ electrolyte of SOFC is plasma spraying. This system heats particle to a melting point and then pushing them into target and forming a deposition. This paper presents heating studies of YSZ particle in plasma jet. By simple model it is shown that the required time such those YSZ particle with grain size of 50 ?m to be melt is around 12 x 10-4 second. (author)
A combined gas/steam turbine process includes a high-pressure furnace and a high pressure gasification unit with a mounted upstream of a combustion chamber there is a gas turbine with a waste heat system. Combustion heat which is not needed to heat the flue gas to combustion temperature is released from the furnace and transferred to ths combustion air going into the combustion chamber.
Equations are compiled for thermal balance in which for simplification, no consideration is made for heat conductivity along the axis of the cable and dependence of losses, heat capacitance and heat conductivity on temperature. Equations are modeled on a transistor analog calculator 42 TA. The solution to the task on the computer produced values of maximum temperature on the cable and coordinates of the point of maximum overheating. Using the analog model, one can study other parameters of the thermal mode.
Granted patents are an important source of information on the potential commercialization of augmented heat transfer technology. This report presents a bibliography of US patents pertinent to that technology. The total number of patents cited is 321. They are presented in three separate lists: by patent number, alphabetically by first inventor, and by augmentation techniques (with secondary arrangement according to mode of heat transfer).
An analysis of trapezoidal profile convective pin fins, with internal heat generation density is presented. The solution of the optimal problem is also given, when either the desired heat dissipation rate or the volume of the pin is specified. The results are presented graphically and in polynomial forms that are particularly useful for computerized calculations. The effect of the fin`s profile and thermal conductivity upon the optimum dimensions is discussed. An example serves to demonstrate the usefulness of the method.
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on ...
This article identifies the key role of the sugar industry in the rural development of developing countries. The Indian sugar industry, already second largest among the country`s processing industries, shows even greater potential, according to the Plan Documents (shown in a table). The potential of waste heat in sugar processing plants, which produce white crystal sugar using the double sulphitation clarification process, is estimated at 5757.9 KJ/kg of sugar. Efficient waste heat recovery (WHR) systems could help arrest the trend of increasing production costs. This would help the sugar industry not only in India, but in many other countries as well. The innovative methods suggested and discussed briefly in this article include dehydration of prepared cane, bagasse drying, and juice heating using waste heat. These methods can reduce the cost of energy in sugar production by at least 10% and improve ...
The effects of the heating rate from 0.6 up to 50{sup o}C.s{sup -1} on the thermoluminescence of {alpha}-Al{sub 2}O{sub 3}:C are very intensive. The material rapidly loses its high sensitivity as the heating rate increases. The peak shape characteristics, peak maximum and full width at half maximum agree only qualitatively with those theoretically predicted. The trapping parameters calculated by the curve fitting method, the peak shape method, the variable heating rate method and the initial rise method, were found to decrease as the heating rate increases. The validity of the results are discussed in the framework of the kinetic models. (author).
The effects of the heating rate from 0.6 up to 50"oC.s"-"1 on the thermoluminescence of #alpha#-Al_2O_3:C are very intensive. The material rapidly loses its high sensitivity as the heating rate increases. The peak shape characteristics, peak maximum and full width at half maximum agree only qualitatively with those theoretically predicted. The trapping parameters calculated by the curve fitting method, the peak shape method, the variable heating rate method and the initial rise method, were found to decrease as the heating rate increases. The validity of the results are discussed in the framework of the kinetic models. (author).
The effect of heat treatment on the corrosion behavior of reactive plasma sprayed TiN coatings in simulated seawater was investigated by electrochemical methods such as the corrosion potential-time curve (Ecorr-t), potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and SEM, etc. The results showed that the corrosion potential of TiN coatings increased after heat treatment; the corrosion current of the TiN coatings after heat treatment (be hereafter referred to as HT-TiN) was 13.3% of the untreated coatings (be hereafter referred to as UT-TiN), and the polarization resistance of HT-TiN was 20 times of UT-TiN, which indicated that the heat treatment had significantly increased the corrosion resistance of the coatings. The corrosion behavior of the coatings was mainly ...
A solar thermal powered aircraft powered by heat energy from the sun. A Rankine-Brayton hybrid cycle heat engine is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller or other mechanism for enabling sustained free flight. The Rankine-Brayton engine has a thermal battery, preferably containing a lithium-hydride and lithium mixture, operably connected to it so that heat is supplied from the thermal battery to a working fluid. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, ...
A method for preparing metal for heating by infrared radiance to enable uniform and consistent heating. The surface of one or more metal parts, such as aluminum or aluminum alloy parts, is treated to alter the surface finish to affect the reflectivity of the surface. The surface reflectivity is evaluated, such as by taking measurements at one or more points on the surface, to determine if a desired reflectivity has been achieved. The treating and measuring are performed until the measuring indicates that the desired reflectivity has been achieved. Once the treating has altered the surface finish to achieve the desired reflectivity, the metal part may then be exposed to infrared radiance to heat the metal part to a desired temperature, and that heating will be substantially consistent throughout by virtue of the desired reflectivity.
Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)
Because power requirements in induction heating applications are largely dependent on the physical properties of the product to be heated, inducting, heating is mainly used in steelwork applications, for the manufacture of finished or semi-finished parts. Applications here cover five main types of steelworks operation: smelting, heating prior to forming, heat treatment, surface treatment, and assembly process. At the same time, technological progress has opened up innovative applications in sectors such as chemical and agro-food industries. Other emerging applications for induction include direct forming of liquid metal, wholly or partially replacing mechanical transformations on solid metal. Techniques include electromagnetic forming, continuous cold-crucible casting, electromagnetic mixing, flow control by continuous magnetic field, and production of intense sliding fields (pumps, ...
In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...
A method of modeling freeze-thaw cycles of naturally deposited snowpacks is presented. The model involves the Stefan condition as an independent governing equation on the exterior moving boundary to calculate snowpack thinning, flow of water through a variably saturated layered porous medium as described by the Richards equation, and heat conduction with a phase change. The heat conduction problem was treated in two ways. Local heat conduction between a snow grain and its surrounding water film was treated by using a simple energy balance. Global heat conduction with a phase change (the Stefan problem) was introduced to calculate the space-time temperature distribution. In order to handle multiple interior moving boundaries, a specific form of the enthalpy formulation was used for heat conduction with a phase change. Changing material properties were considered according to the ...
The divertor collector plate in the INTOR reactor will be subjected to high heat, particle, and neutron fluxes, making it the most severely damaged torus component. The collector plate is composed of a protection plate, which is directly exposed to the particle flux, and a heat sink which provides support for the protection plate and carries the water coolant. The high-Z refractory metals have been considered for use as the protection plate material, and austenitic stainless steels and copper alloys have been considered as the heat sink material. Tungsten and Type 316 stainless steels have been selected for the protection plate and heat sink, respectively. The protection plate has a sputtering lifetime of 1.75 y at a 50% duty factor, while the heat sink is expected to last the lifetime of the reactor.
The local heat transfer coefficient distribution of a square channel with two opposite ribbed walls was determined. The square channel was connected to a sudden contraction entrance in order to simulate the inlet condition of the turbine blade cooling passages. The test channel was heated by thin stainless steel foils with a thickness of 0.000025 m, and instrumented with 180 thermocouples. The brass ribs of a square cross-section were glued periodically, in line, onto the top and bottom walls of the foil-heated channel in patterns to achieve the desired spacing and angle-of-attack. The local heat transfer coefficients on the smooth side and the ribbed side walls, at the channel entrance and the downstream regions, were measured for eight rib configurations and three Reynolds numbers (Re = 10,000, 30,000, and 60,000).
Apart from presenting the marginal legal conditions the research program contains a brief description of current pollution abatement measures, representative heating systems and individually suitable pollution abatement technologies and an account of the determination of the concentration of major pollutants. The comparative evaluation of heating systems assesses their environmental effects, i.e. air pollution caused by heating systems. The determination of the costs of available heat is followed by an overall evaluation of the results obtained with special regard to the costs involved by pollution abatement measures.
Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.
This paper presents the experimental results of heat transfer augmentation in an axisymmetric jet impinging normally on a flat plate surface without the requirement of additional pumping power. The present technique of augmentation utilizes only a punched plate with circular holes arranged in a triangular array, fixed parallel to, just in front of the heated target plate. Near the optimum conditions determined, the heat transfer coefficient at the geometrical stagnation point can be increased 4 times. Additional flow visualization study indicates that this augmentation mechanism creates an improved flow field where the punched plate acts as a detached fin, the conductivity of which may be exploited for further augmentation. Besides augmentation, the present investigation foresees the possibility of manipulating the distribution of local heat transfer rate by varying few parameters.
This publication contains the Ordinance on Heating Costs, the Ordinance on Heating Installations, and the 1st Federal Ordinance on Emission Control (BImSchV) concerning Small-Scale Furnaces, in each case with notes and explanations. All these ordinances aim at reducing energy consumption in connection with heating; the 1st BImSchV also at air pollution abatement by lowering the permissible limiting values for soot and flue gas. The three ordinances also apply to housing property. (HSCH).
The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.
Initial ICRF heating experiment in the LHD was carried out in 1998. One pair of the movable loop antennas was used and the coupling resistance was around one ohm for the low density ECH plasma. The loading characteristics were consistent with the fast wave excitation. By applying the ICRF heating of 300 kW to the ECH target plasma, the diamagnetic energy was increased from 13 kJ to 26 kJ. The heating performance was decided by hydrogen mixture rate on puffing gas. Efficient electron heating was observed at the higher hydrogen gas ratio. These results can be explained by the one dimensional wave analysis calculation on slab plasma model. (J.P.N.)
An evaluation of Enova's heating program is presented. The central point was to evaluate to which degree Enova's heating program had resulted in increased supply of renewable energy for heating purposes to the Norwegian energy system. Main results are presented in part 1, chapter 1 to 5, while the facts and analyses behind the evaluation are presented in part 2, chapter I to VII. The main conclusion is that the program seen as one has had triggering effect on the market. The program has thus provided results in the form of increased supply of heating energy. Because of the project limitations and the lack of systematically documented baselines in the procedures, there are insecurities connected to the exact data registered. This makes quantification of the results difficult (ml)
The objective of this study is to analyze the effects of heat loss characterized by a percentage of the fuel's energy, friction and variable specific heats of working fluid on the performance of an air standard Otto cycle with a restriction of maximum cycle temperature. A more realistic and precise relationship between the fuel's chemical energy and the heat leakage that is based on a pair of inequalities is derived through the resulting temperature. The variations in power output and thermal efficiency with compression ratio, and the relations between the power output and the thermal efficiency of the cycle are presented. The results show that the power output as well as the efficiency where maximum power output occurs will increase with increase of the maximum cycle temperature. The temp...
The electrically heated rod is usually used as a substitute for fuel rod in thermal-hydraulic experiment. However, the different structure and thermal properties between nuclear fuel rod and electrically heated rod result in different steady-state distribution of temperature and stored energy and different response to thermal-hydraulic in simulation transient experiment. This paper analyses the effect of structure and thermal properties differences between nuclear fuel rod and electrically heated rod on experiment, and then introduce a feasible method, i.e. electric power is controlled by a program, to reduce the differences between the transient responses of nuclear fuel rod and electrically heated rod. At the same time, this paper points out the limits of the method. (authors)
The fully developed electrically conducting micropolar fluid flow and heat transfer along a semi-infinite vertical porous moving plate is studied including the effect of viscous heating and in the presence of a magnetic field applied transversely to the direction of the flow. The Darcy-Brinkman-Forchheimer model which includes the effects of boundary and inertia forces is employed. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. Profiles for velocity, microrotation and temperature are presented for a wide range of plate velocity, viscosity ratio, Darcy number, Forchhimer number, magnetic field parameter, heat absorption ...
It is planned to bulk-heat a unit cell of a fusion reactor solid-breeder blanket in a fission reactor to study thermo-mechanical and thermal-hydraulic properties of fusion blankets. This study investigates the neutronic feasibility of using the Power Burst Facility (PBF) for this purpose. Heating rates were calculated for a Li/sub 2/O experiment placed in the PBF test space. The ANISN code and a 56-group coupled neutron-gamma library based on FLUNG and VITAMIN C were used to compute the heating rates. The results show that an average heating rate level of 1-3 W/cc can be produced in PBF with a local power profile that should be typical of a fusion blanket unit cell.
The atomic mechanism of a glass-to-liquid transition in a monatomic Lennard-Jones (LJ) glass was studied using the molecular dynamics (MD) method. Glassy models were heated up from low temperature at two different heating rates and a glass-to-liquid transition found to occur at the higher heating rate. The temperature dependence of the potential energy, mean-squared-displacements (MSD) of the atoms and the self-intermediate scattering function indicate clearly that a glass transition occurs in the system. The atomic mechanism of the glass-to-liquid transition was investigated by analyzing the spatio-temporal arrangement of liquid-like atoms in the system upon heating. Liquid-like atoms were detected using the Lindemann-melting-like criterion. Upon heating, liquid-like atoms occur at temper...
The major goal of this continuation project is to advance the utilization of heat transfer enhancement techniques in commercial heat exchange equipment. Thirteen heat transfer enhancement techniques have been identified as having potential for improving heat transfer coefficients in full-scale industrial equipment. The following tasks are part of this project, which was originally planned for three years: (1) expansion of technology information base; (2) evaluation of performance of enhanced surfaces and inserts; (3) correlation of data for spirally fluted surfaces; (4) study of structured surfaces in pool boiling; and (5) study of structured surface in spray film evaporation.
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...
Counter rotating longitudinal vortices produced by winglet in a channel are known to enhance heat transfer. In the present investigation the flow structure and heat-transfer enhancement by a winglet pair of non-zero thickness has been studied. A delta winglet pair type vortex generator is placed in a hydrodynamically developed and thermally developing laminar channel flow. Computations are done by solving the unsteady, three-dimensional, incompressible Navier-Strokes equations and energy equation using a modified Marker-and-Cell (MAC) method. The flow structure is complex and consists of main, corner and induced vortices. It is observed that as compared to a channel without winglets, the heat transfer is enhanced by 33% when single winglet is used and by 67% when a winglet pair is employed. Effects of thickness of the winglets and Reynolds number on the heat transfer augmentation are presented.
The fundamental differences in the type of products sold in both Japan and the US, and some of the reasons for these differences, are outlined. Japan is the largest single country market for residential heat pumps, while the US represents the largest single country market for residential heating equipment. Quite different types and associated features of heat pumps are demanded in the USA and Japan. The term `convenience features`, used to describe the physical characteristics of the user interface device, is explained, as well as the fundamental reasons leading to the particular styles of product sold in each country: (1) product strategy and sales channels, (2) design of housing, (3) climatic factors, and (4) energy costs and distribution. It is stressed that there is no big cooling load in Japan. It is rather the comfort issue that drives the market for heat pumps
The Supercritical Water Cooled Reactor(SCWR) operates in a pressure around 25MPa and temperature of 293#approx#510 .deg. C. In order to study the heat transfer behaviors and good comparisons between the various fluids, a heat transfer test loop(SPHINX) using CO_2 has been constructed in KAERI as a part of international research program, I-NERI. At a supercritical pressure, the heat transfer coefficient is much larger than that estimated from the Dittus-Boelter correlation for a relatively large flow rate with moderate wall heat flux conditions. This phenomenon was explained by the rapid variations of the physical properties near the wall with the temperature. On the contrary, the heat transfer becomes worse when the bulk fluid enthalpy is below the pseudo-critical enthalpy under a low flow rate with large heat flux conditions. This phenomenon is called ...
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the ...
The deep borehole heat exchanger (BHE) of Weggis is operational since 1994. During the years 1995 to 2000 the BHE has produced for both, direct heating and as a source for the heat pumps, a yearly amount of heat of 220 MWh. The share of direct heating has been more than 60%. The global average power delivered to all consumers has been about 100 kW. This has yielded to a mean source temperature out of the deep BHE of 40.5 {sup o}C and to a mean return temperature of 33.3 {sup o}C. During the years 2000 and 2001 three additional multi-family dwellings have been connected as heat consumers to the BHE. The amount of delivered heat has nearly been doubled (from 220 to 440 MWh per year) as well as the nominal load. This has induced a small reduction of the delivery temperature and a significant reduction of the return temperature to the BHE (37.2 ...
In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the ...
Oil/electric heating systems and energy measuring instrumentation were installed in 50 houses in Deep River, Ontario. These were operated and monitored for two heating seasons to demonstrate their performance and determine the percentage oil placement as a function of heater capacity and control system. All experimental data was stored and processed by computer. It was found that oil furnace utilization efficiency varied from 48 to 59% for an average of 53.5%. Oil displacement ranged from 49 to 83% for 2.5 and 5.0 kW electric heaters controlled by two-stage indoor thermostats. Fuel costs for oil/electric hybrid heating, with 5.0 kW plenum heaters and indoor two-stage thermostats, were 20% less than for oil heating, based on average furnace efficency and 1983 January retail fuel prices. Annual load factors above 37% were achieved for plenum heaters compared to 11.9% for all-electric systems. Space ...
A three-dimensional steady numerical computation was made for a component model of fin and tube type of compact heat exchangers situated in a uniform flow. In this study, in order to find a clue to design high-efficient heat exchangers, numerical computation was made in the case where two fences are attached on the plate fin surface and their geometrical effects such as their locations, their heights and their attack angles on flow and heat transfer characteristics were investigated especially in the low Reynolds number range. The effect of a hole, open in the plate fin behind the fence, on heat transfer and flow structures was also examined. This hole simulates the hole of the plate fin to be produced in practical application, when a fence is produced by punching from the original plain fin plate. Two fences with holes were found to show several important effects on flow and heat ...
Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower ...
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on current design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer ...
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on ...
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on ...
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on ...
The purpose of this study is to determine the thermal reliability of stearic acid, palmitic acid, myristic acid and lauric acid as latent heat energy storage materials with respect to various numbers of thermal cycles. The fatty acids, as phase change materials (PCMs), of industrial grade (purity between 90% and 97%) were subjected to accelerated thermal cycle tests. The differential scanning calorimetry (DSC) analysis technique was applied to the PCMs after 0, 120, 560, 850 and 1200 melt/freeze cycles in order to measure the melting temperatures and the latent heats of fusion of the PCMs. The DSC results indicated that the change in melting temperature for the PCMs was in the range of 0.07-7.87 {sup o}C, and the change in latent heat of fusion was -1.0% to -27.7%, except for stearic acid between 560 and 1200 melt/freeze cycles. However, the decrease in the latent heats of fusion for all the PCMs was ...
The purpose of this study is to determine the thermal reliability of stearic acid, palmitic acid, myristic acid and lauric acid as latent heat energy storage materials with respect to various numbers of thermal cycles. The fatty acids, as phase change materials (PCMs), of industrial grade (purity between 90% and 97%) were subjected to accelerated thermal cycle tests. The differential scanning calorimetry (DSC) analysis technique was applied to the PCMs after 0, 120, 560, 850 and 1200 melt/freeze cycles in order to measure the melting temperatures and the latent heats of fusion of the PCMs. The DSC results indicated that the change in melting temperature for the PCMs was in the range of 0.07-7.87 deg. C, and the change in latent heat of fusion was -1.0% to -27.7%, except for stearic acid between 560 and 1200 melt/freeze cycles. However, the decrease in the latent heats of fusion for all the PCMs was not ...
Heating during frictional sliding is a major component of the energy budget of earthquakes and represents a potential weakening mechanism. It is therefore important to investigate how heat dissipates during sliding on simulated faults. We present results from laboratory friction experiments where a halite (NaCl) slider held under constant load is dragged across a coarse substrate. Surface evolution and frictional resistance are recorded. Heat emission at the sliding surface is monitored using an infra-red camera. We demonstrate a link between plastic deformations of halite and enhanced heating characterized by transient localized heat spots. When sand 'gouge' is added to the interface, heating is more diffuse. Importantly, when strong asperities concentrate deformation, significantly more heat is produced locally. In natural faults such ...
This paper states the concept of a heat-resistant structure of the HOPE airframe having a 10 ton weight when lifting off and also the research situation of heat-resistant structural materials. To study the structure, established are design conditions for lift-off, reentry to the atmosphere and landing. As to the load condition, the load at the time of lift-off is most critical. Relating to the temperature environment condition, thermal analysis is made of the time when a HOPE is on the orbit (low-temperature range) and reenters the atmosphere (high-temperature range), when the temperature environment is critical. The analysis shows that the temrerature environment is in a {minus}80-1700{degree}C (range). The heat-resistant structural materials are developed so as to meet these conditions. The paper describes distribution of the airframe surface temperature by aerodynamic heating at the reentry, ...
Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it will be examined all ...
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ ...
The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heat exchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting flow guide-plates could not be expected large effects on the heat transfer ...
This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance for space heating was ...
An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that ...
The studies of forced jet augmentation of natural convection heat transfer are introduced. It investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large rectangular enclosure with a vertical cooling surface. The experiment is designed to measure the key parameters governing the heat transfer augmentation by a forced jet, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio, on conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The tests that cover a variety of injection modes will contribute to reveal the nature of mixing and stratification phenomena under accident conditions to a new generation of inherently safe reactors. With similarity considerations on governing equations, the ...
Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated in the natural convection dominated region for a wide range of Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.02win0.025m/s) using a flow rate control valve so that Reynolds number was always about ...
Alloy 800 from three different commercial heats have been continuously cycled and cycled with a hold period at 922/sup 0/K. The starting microstructures of these heats reflects an inherently wide spectrum of possibilities for Alloy 800. The amounts and morphologies of the TiC and M/sub 23/C/sub 6/ carbides are different among the heats. During cycling, M/sub 23/C/sub 6/ forms intragranularly in a solution annealed heat. This precipitation contributes to the cyclic hardening. Both mill annealed heats of Alloy 800 are stable to carbide precipitation during cycling. The heat with the lower carbon content formed ..gamma..' during cycling but the volume fraction was too low to contribute to hardening. The inclusion of hold periods caused the dislocation substructure to become more diffuse in the mill annealed heats. The cyclic hardening ...
Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the tube wake. For Re = 300 and Fi = 200 the global heat transfer ...
An investigation was given on the relationship between methanol adsorbing behavior of reformed coal surface and oxygen containing functional groups in coal. Akabira bituminous coal was air-oxidized or Yallourn brown coal was decarbonated in oil as a reformation treatment. Both of the treated and untreated coals showed an adsorption heat curve of the Langmuir type. The Akabira coal had its oxygen content and the adsorption heat increased as a result of the air oxidizing reformation treatment. The Yallourn coal had its oxygen content and adsorption heat decreased as a result decarbonation reformation treatment. Oxygen containing functional groups act as strong adsorption sites for methanol, and the maximum adsorption amount depends on oxygen content in the coals. Since the coal surface is non-uniform in terms of energy, methanol is adsorbed first into sites with higher molar adsorption heat, and then into ...
T-history method, developed for measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and convenience with no sampling process. However, some improper assumptions in the original method, such as using a degree of supercooling as the end of latent heat period and neglecting sensible heat during phase change, can cause significant errors in determining the heat of fusion. We have improved this problem in order to predict better results. The present study shows that the modified T-history method is successfully applied to a variety of PCMs such as paraffin and lauric acid having no or a low degree of supercooling. Also it turned out that selected periods for sensible and latent heat do not significantly affect the accuracy of heat- of-fusion. As a result, the method can provide an appropriate ...
A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heat exchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic curves of the system are presented for some given parameters. Several interesting ...
Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat ...