BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Dopplerultrasound (TVCD) may predict those prognostic factors...Full Text Available
This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according...Full Text Available
OBJECTIVE: To evaluate the interobserver agreement of ultrasonographic assessment of finger and toe joints in patients with rheumatoid arthritis (RA) by 2 investigators with different medical backgrounds. METHODS: Ultrasonography and clinical examination were performed on 150 small joints of 30 patients with active RA. A General Electric LOGIQ 500 ultrasound unit with a 7-13-MHz linear array transducer was used. In each patient, 5 preselected small joints (second and third metacarpophalangeal, second proximal interphalangeal, first and second metatarsophalangeal) were examined independently on the same day by 2 ultrasound investigators (an experienced musculoskeletal radiologist and a rheumatologist with limited ultrasound training). Joint effusion, synovial thickening, bone erosions, and power Doppler signal were evaluated in accordance with an introduced 4-grade semiquantitative scoring system, on ...
With the increased usage of dispersion models that require stack top wind information, such as the Complex Terrain Dispersion Model (CTDM), the need for a reliable method to collect elevated wind data has also increased. Doppler Sound Detection and Ranging (SODAR) instruments have gained recognition as a viable means of collecting such data. SODAR technology has improved greatly over the last decade and is now a cost effective alternative to tall meteorological towers. SODARs are remote sensing devices that sample the atmosphere and calculate wind speed and wind direction data at different altitudes. This is accomplished by measuring the doppler shift of an acoustic pulse emitted by a ground level antenna.
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 ...
The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. ...
We have developed a transportable container based direct detection Doppler lidar based on the double-edge molecular technique. The pulsed solid state system was built at the University of Geneva. It was used to make range resolved measurements of the atmospheric wind field as part of the VALID campaign at the Observatoire de Haute Provence in Provence, France in July 1999. Comparison of our lidar wind measurements, which were analyzed without knowledge of the results of rawinsonde measurements made under the supervision of ESA, show good agreement with these rawinsondes. These are the first Doppler lidar field measurements made with an eyesafe direct detection molecular-based system at 355 nm and serve as a demonstrator for future spaceborne direct detection wind systems such as the Atmospheric Dynamics mission. Winds are an important contributor to sea surface temperature measurements made with the Tropical Rainfall ...
A method for quick, high-accuracy measurement of lithium isotopes has become necessary in carrying out research on the separation and concentration of lithium isotopes by ion exchange. The present report focuses on the application of a hollow cathode, as excitation source, to emission spectral analysis for lithium isotope measurement. The grating monochromator used incorporates a pressure scanned etalon. With decreased Doppler broadening and pressure broadening, the hollow cathode, used as excitation source, can give narrow spectral lines, permitting good separation among them. To achieve a high accuracy, the emission intensity of the hollow cathode should be maintained as stable as possible relative to time. In particular, the stability of a light source can be affected significantly by the chemical form of the sample. A study is also made here to identify a condition where lithium acetate effluent as-obtained from an ion exchange column can be excited for ...
This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at DopplerUltrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion ...
The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the ...
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design ...
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles ...
BackgroundPregnancies complicated by abnormal umbilical artery Doppler blood flow patterns often result in the baby being born both preterm and growth-restricted. These babies are...Full Text Available
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The ...
The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available
We investigate a method for gene delivery to vascular smooth muscle cells using ultrasound triggered delivery of plasmid DNA from electrostatically coupled cationic microbubbles. Microbubbles...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available
Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, measurements have ...
Sep 19, 2011 ... (The whispering voice, on the other hand, was the latest in ultrasound directed audio technology from the firm Audio Spotlight.) The NASA ...
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...
Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.
Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available
BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available
Discussions on a form of a frequency spectrum of wind-driven sea waves just above the spectral maximum continue during the last three decades. In 1958 Phillips made a conjecture that wave breaking is the main mechanism responsible for the spectrum formation. That leads to the spectrum decay $\\sim \\omega^{-5}$, where $\\omega$ is the frequency of the waves. There is a contradiction between the numerous experimental data and this spectrum. The experiments show decay $\\sim\\omega^{-4}$. There are two general ways of the explanation of this phenomenon. The first one (proposed by Banner (1990)) takes into account the Doppler effect due to surface circular currents generated by long waves in the Phillips model. The second approach ascends to the work by Zakharov and Filonenko (1968). It is based on four-wave interactions in the kinetic equation and gives good agreement with the experimental data. In this article the contribution to the Phillips model due to the ...
Cavity ringdown spectroscopy (CRDS) with continuous-wave (cw) laser excitation has added high frequency resolution to the ability of CRDS being used for the absolute quantification of trace-level species present in many chemical processes. Cavity dithering technique has easily resolved the problem of resonant coupling of a cw laser light into a high-finesse cavity. The present study addresses the potential uncertainty involved in such cw-CRDS techniques incorporating the cavity mirror motion, i.e., the doppler frequency shift of a probe light inside the cavity. In the high-resolution spectroscopic work of megahertz-accuracy, even the influence of intracavity doppler effect may become significant.
Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...
The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
BackgroundThe presence of enthesitis (insertional inflammation) in patients with juvenile idiopathic arthritis (JIA) is difficult to establish clinically and may influence classification...Full Text Available
Variations in skin perfusion are easily detected by laser speckle contrast maps, but a robust interpretation of the information has been lacking. We show that multiple-exposure laser speckle methods produce the same spectral information as laser Doppler methods when applied to targets with embedded moving scatterers. This enables laser speckle measurements to be interpreted more quantitatively. We do this by using computer simulation of speckle data, and by experimental measurements on Brownian motion and skin perfusion using a laser Doppler system and a multiple-exposure laser speckle system. The power spectral density measurements of the light fluctuations derived using both techniques are exactly equivalent. Dermal perfusion can therefore be measured by laser Doppler or laser speckle contrast methods. In particular, multiexposure laser speckle can be rapidly processed to generate a full-field map of the perfusion index ...
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of complicating factors ...
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available
Instantaneous cross sectional flow velocity profiles from early mitral flow in 10 healthy men were constructed by time interpolation of the velocity data from each point in sequentially delayed two...Full Text Available
BackgroundAtrial fibrillation (AF) is the most common cardiac arrhythmia with a population prevalence of about 1%. Natriuretic peptide level is elevated in patients with AF with...Full Text Available
BackgroundEchocardiography is widely used in the management of patients with cardiogenic shock (CS). Left ventricular ejection fraction (EF) has been shown to be an independent predictor...Full Text Available
Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.
Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available
BackgroundLifestyle, genetics and environmental factors are established determinants of bone density. We aimed to describe the bone characteristics of competitive top-ranked Nigerian...Full Text Available
An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available
To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...
The dynamical decoupling (DD) aims at suppressing the decoherence by means of coherent control pulses. Even if devices exist where instantaneous pulses are an adequate approximation, experimentally a finite duration #tau#_p and a bounded amplitude are inevitable. They are the cause of additional errors which can be corrected by designing the pulse shape appropriately. The new pulse has the overall effect of an ideal, instantaneous pulse with the advantage of decoupling the spin (or qubit) from the bath up to the order O(#tau#_p"3). The limitation of the no-go theorem for #pi# pulses is avoided. Hence, the Uhrig sequence (UDD), originally thought for ideal #pi# pulses, works also for bounded control Hamiltonians. Numerical simulations show that concatenated sequences of real pulses are effective against general ...
Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with frequency-dependent time lag ...
In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic wave propagation in a complicated ...
Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle flow rate by at most 19 percent, with some of the difference due to evaporation. The ...
Abstract In this paper, the effect of several turbulence parameters during various flow conditions in Owens Valley, educed from coherent Doppler lidar data have been studied. Radial velocity structure functions are processed to estimate the turbulent kinetic energy (TKE) dissipation rate, integral length scale and velocity variance, assuming a theoretical model for isotropic wind fields. Corrections for turbulence measurements have been considered to address the complications due to inherent volumetric averaging of radial velocity over each range gate, noise of the lidar data, and the assumptions required to estimate effects of smaller scales of motion on turbulence quantities. Using data from the Terrain-induced Rotor Experiment (T-REX) in April-May 2006, vertical profiles of wind and tur...
Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).
Quantitative, experimentally based assessments of the biases of the methods used to develop the neutronics design of the FTR are presented together with brief descriptions of the design methods. Uncertainties in biases have been established that are sufficiently small to allow a high degree of confidence in the nuclear design. Experimental data for these assessments have been developed in full-scale zero-power mockups of the final design of the reactor, except for Doppler data from SEFOR. Temperature, power coefficient, and stability methods evaluations are necessarily deferred to acceptance testing during initial startup of the FTR. Sodium voiding and small sample worths continue to be the technical areas of greatest complexity with least experiment-theory correlation. Critical mass, Doppler effects, control rod worth, and spatial power distribution have generally good experiment-theory correlations.
The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.
We have measured the isotope shifts of some dipole transitions between excited states of the even strontium isotopes 88 and 86 by applying the technique of Doppler-free intermodulated optogalvanic spectrocopy to a heat-pipe discharge. We were also able to investigate the isotope shift of the Sr II resonance line at 4216.6 A optogalvanically in the mentioned pair of isotopes. Because the 5 snf"1F_3 series appear to have zero level isotope shifts for n>=6, we can give residual level isotope shifts (RLIS) of several odd-parity states of sup(88,86) Sr I. The RLIS of the 5 snp "1P_1 series show pronounced configuration mixing around n=7. (orig.).
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed.
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed. (author).
A univibrator and a pulse height discriminator using tunnel diodes and backward diodes are described, along with their applications in pulse shaping and fast coincidence technique. The main advantages achieved are simplicity of design and speed. The characteristics of the two diodes are shown. (auth)
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...
Background and ObjectivePulsed dye laser (PDL) treatment of cutaneous vascular lesions is associated with variable and unpredictable efficacy. Thus, alternative treatment...Full Text Available
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...
Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...
17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).
Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...
Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...
Various topics include: (1) direction finding, (2) range finding, (3) Doppler measurements, (4) construction of a receiver for radio interferometry, (5) mobile laser range finding system, (6) figure-and field parameter determination/geopotential, (7) dynamics of the Earth-Moon system, and (8) kinematics of geodetic point fields.
An investigation of natural convection losses from cavity-type solar central receivers is described and results are given. The approach followed was that of a fundamental experimental study in a simple cavity subject to well controlled boundary conditions. The Laser Doppler Velocimeter proved to be a useful technique to measure the velocity profiles associated with natural convection. Visualization techniques provided an understanding of the general behavior of the flow, particularly in three dimensional experiments. Experiments on systems of high Rayleigh numbers are described. (LEW)
Acoustic waves propagation of in composite of water with embedded double-layered silicone resin/silver rods is considered. Approximate values of effective dynamical constitutive parameters are obtained. Frequency ranges of simultaneous negative constitutive parameters are found. Localized surface states on the interface between metamaterial and ``normal'' material are found. Doppler effect in metamaterial is considered. Presence of anomalous modes is shown.
Laser-Doppler anemometry was used to investigate mean flow and turbulence fields in a direct injection diesel engine, motored at speeds of 1500, 2250 and 3000 rev/min. Both cycle-resolved and ensemble-averaged measurements were made in the upper part of the cylinder during the inlet and compression strokes. The cycle-resolved measurements in the inlet stroke are discussed in this paper.
A device for marking and searching for information on a magnetic carrier is described. In order to increase the noise immunity and reliability of the data recording and reading paths, the recording head is included between the amplifier of the clock pulses for the master oscillator and through the amplifier of the code pulses for the logical element unit. The reproduction head is connected through the code pulse shaper-amplifier with a switch which is connected with the display unit, and through another analogous clock pulse amplifier with a multivibrator.
The wavelength of the free electron laser (FEL) in Osaka University can be continuously varied in the range of 5.0-20.0 #mu#m. The FEL has a double-pulse structure, consisting of a train of macropulses of pulse duration 12 #mu#s. Each macropulse contains a train of 330 micropulses of pulse duration 5 ps. The tunability and picosecond pulses afford new medical and biological applications. However, a macropulse of long pulse duration leads to undesirable secondary effects. Precise control of the macropulse duration is essential for the high-precision applications of the FEL. An FEL pulse control system using acousto-optic modulators has been developed to investigate mechanical (shock-wave) effects of the FEL on living tissues. With this system, we have controlled photoinduced shock waves and determine the mechanism of interaction during FEL-induced tissue ...
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
The barrier glow discharge between two planar electrodes, covered with dielectric, is studied under high-voltage pulsed power supply. Wide applications of such type of discharges, in particular, for ozone production, stimulated a number of investigations in this direction. In this work we investigated the dependence of ozone concentration on the duration and the rate of pulse rise of the applied voltage. The thyristor converter circuit with the shortening of input pulses on the base of the saturable throttle was used for the realization of this task. The output pulses with amplitude up to 15 kV, repetition frequency of 1 kHz, pulse duration of 0.3 #mu#s (or 7 #mu#s) and the rate of pulse rise of 0.1 #mu#s were generated with this scheme. Measurements of the ozone concentration produced in the air mixture have shown that its value increased by factor two with ...
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks ...
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can ...
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
In a seeded high-gain free-electron laser (FEL), where a coherent laser pulse interacts with an ultrarelativistic electron beam, the seed laser pulse can be frequency chirped, and the electron beam can be energy chirped. Besides these two chirps, the FEL interaction introduces an intrinsic frequency chirp in the FEL even if the above-mentioned two chirps are absent. We examine the interplay of these three chirps. The problem is formulated as an initial value problem and solved via a Green function approach. Besides the chirp evolution, we also give analytical expressions for the pulse duration and bandwidth of the FEL, which remains fully longitudinally coherent in the high-gain exponential growth regime. Because the chirps are normally introduced for a final compression of the FEL pulse, some conceptual issues are discussed. We show that to get a short pulse duration, an energy ...
In the process of backward Raman amplification (BRA), the leading layers of the seed laser pulse can shadow the rear layers, thus weakening the effective seeding power and affecting parameters of output pulses in BRA. We study this effect numerically and also analytically by approximating the pumped pulse by the ''*-pulse'' manifold of self-similar solutions. We determine how the pumped pulse projection moves within the *-pulse manifold, and describe quantitatively the effective seeding power evolution. Our results extend the quantitative theory of BRA to regimes where the effective seeding power varies substantially during the amplification. These results might be of broader interest, since the basic equations, are general equations for resonant 3-wave interactions.
The effect of asymmetric laser pulses on electron yield from a laser wakefield accelerator has been experimentally studied using > 10{sup 19} cm{sup -3} plasmas and a 10 TW, > 45 fs, Ti:Al{sub 2}O{sub 3} laser. Laser pulse shape was controlled through non-linear chirp with a grating pair compressor. Pulses (76 fs FWHM) with a steep rise and positive chirp were found to significantly enhance the electron yield compared to pulses with a gentle rise and negative chirp. Theory and simulation show that fast rising pulses can generate larger amplitude wakes that seed the growth of the self-modulation instability and that frequency chirp is of minimal importance for the experimental parameters.
An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.
We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler factors, magnetic fields, ...
We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 keV (the average of the blue and red jets) ...
If high-redshift QSOs are ejected from the nuclei of low-redshift galaxies, as some have claimed, a large portion of their redshift must be intrinsic (non-Doppler). If these intrinsic components have preferred values, redshifts will tend to cluster around these preferred values and produce peaks in the redshift distribution. Doppler ejection and Hubble flow components will broaden each peak. Because ejection velocities are randomly directed and Hubble flow components are always positive, in this model all peaks are expected to show an asymmetry, extending further out in the red wing. If peaks are present showing this predicted asymmetry, it can lead directly to an estimate of quasar distances. Using two quasar samples, one with high redshifts and one with low, it is shown here that not only do all peaks in these two redshift distributions occur at previously predicted preferred values, they also all show the predicted extra extension in the red ...
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
Steeghs et al. (1997) have found the first convincing evidence for spiral structure in the accretion disc in IP Pegasi. We perform two kinds of 2D hydrodynamic simulations, a SFS finite volume scheme and a SPH scheme, in the case of mass ratio of 0.5. Both results agree well each other. We construct the Doppler maps and line flux-binary phase relation based on the density distributions. Both of our results agree well with those obtained by the observation.
Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.
Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.
A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.
For the determination of top dead center (TDC) of a running engine a measuring system using microwaves was developed by AEG and Volkswagen AG. The measuring method utilizes the Doppler shift of the microwaves, which were reflected at the up and down moving piston, and the varying resonance properties of the combustion chamber. The system works with a frequency of 61.4 GHz and can be used as well for spark ignition as form compression ignition engines, particularly for direct injection engines. The output signal is symmetrical to TDC. For data acquisition and data processing, i.e. the calculation of the point of symmetry, the computer system FARES is used in a special assembly.
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating ...
Background and ObjectivesDisruption of the vocal fold extracellular matrix (ECM) can induce a profound and refractory dysphonia. Pulsed dye laser (PDL) irradiation...Full Text Available
We have studied both theoretically and experimentally a new scheme of active pulse compression in a free electron laser (FEL) amplifier. The pulse compression scheme presented here is the following. A frequency-chirped pulse is injected into the FEL interaction region. Because of the high gain and narrow bandwidth of the FEL interaction, only the resonant frequency band of the pulse is actively amplified, resulting in a short pulse of high power coherent radiation at the output of the laser. For our experimental parameters (beam voltage #approx =# 150 kV, current #approx =# 5.0 A, wiggler period #approx =# 3.5 cm and gain #approx =# 10 dB), pulses of a few nanoseconds were generated at #approx =# 10 GHz after an interaction length of 2.30 m, in good agreement with theoretical expectations. For the same input pulses (width > 100 ns, ...
The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.
We report coupling and guiding of pulses of peak power up to 0.3 TW in 1.5 cm long preformed plasma waveguides generated in a high repetition rate argon gas jet. Coupling of up to 52% was measured for 50 mJ, -110 fs pulses injected at times longer than 20 ns, giving guided intensities up to -5x1016 W/cm2. It was found that for short delays between waveguide generation and pulse injection, pulse shortening occurred, with this effect reduced as delay was increased. Injection into the waveguide of two consecutive pulses separated by a few nanoseconds resulted in the reduction of shortening of the second pulse at all delays. Femtosecond time-resolved shadowgrams of the coupling of injected pulses into the waveguide show that there is ?0.5 mm of neutral gas remaining at the waveguide entrance after waveguide generation.
This progress report presents a detailed description of the background, technology and application, and Statement of Work for the development of a coal-fired pulse combustor for residential space heating.
A system is claimed for multiplexing or demultiplexing pulsed laser radiation having an acousto-optical device which is electrically controlled to switch a common path of high pulse rate laser radiation between a plurality of spatially distinct paths for relatively lower pulse rate laser radiation at which the pulses are sequenced according to a predetermined time pattern. The acousto-optical element typically includes a Bragg cell which is electrically driven by a set of distinct frequencies, causing deflection of radiation passing therethrough at a predetermined set of angles whereby pulsed radiation on a single path may be distributed onto the plural separate paths or radiation on plural separate paths of time-sequenced pulses of radiation can be combined into a single path of augmented pulse rate. The control of the acousto-optical ...
For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
A line-to-plate reactor was set-up in the experimental study on the application of nanosecond pulsed corona discharge plasma technology in environmental pollution control. Investigation on the attenuation and distortion of the amplitude of the pulse wave front and the discharge image as well as the waveform along the corona wire was conducted. The results show that the wave front decreases sharply during the corona discharge along the corona wire. The higher the amplitude of the applied pulse is, the more the amplitude of the wave front decreased. The wave attenuation responds in a lower corona discharge inversely. To get a higher efficiency of the line-to-plate reactor a sharp attenuation of the corona has to be considered in practical design.
We report on the collision of 1.5 ps (FWHM) laser pulses traversing at 17 a short similar 7 ps (FWHM) 46.6 GeV electron bunch. The phase-locked system used to maintain the correct timing of the laser pulses and the appropriate diagnostics are described. The jitter between the laser and electron pulses is determined from the stability of the observed rate of Compton scatters and can be described by a Gaussian distribution with #sigma#_j#approx =#2.2 ps. (orig.).
We propose using large Air Cerenkov Telescopes (ACT's) to search for optical, pulsed signals from extra-terrestrial intelligence. Such dishes collect tens of photons from a nanosecond-scale pulse of isotropic equivalent power of tens of solar luminosities at a distance of 100 pc. The field of view for giant ACT's can be on the order of ten square degrees, and they will be able to monitor 10 to 10$^2$ stars simultaneously for nanosecond pulses of about 6th mag or brighter. Using the Earth's diameter as a baseline, orbital motion of the planet could be detected by timing the pulse arrival times.
Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions
In this paper, model analysis into the time-dependent transmembrane potential at the outer cell membrane is presented, for applied high-intensity electric pulses having durations in the nanosecond range or smaller. It is argued that the frequency-dependent dielectric response of cell membranes could be used to advantage for stronger bioeffects by employing shorter pulses. Our model calculations predict faster transmembrane voltages and larger electroporation densities for a given external energy with pulse durations in the subnanosecond regime. This temporal regime would be used, for example, in the electrotherapy of mixed cell ensembles having different dielectric response properties. PMID:21937300
in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...
A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185
We report on a time-resolved measurement of self-amplified spontaneous emission free-electron laser (FEL) pulses. We observed that the spikes in such FEL pulses have an intrinsic positive chirp and the energy chirp in the electron bunch mapped directly into the FEL output. The measurement also provides rich information on the statistics of the FEL pulses.
Computer simulations and experiments indicate that we can shape the infrared picosecond pulses of the Mark III FEL in amplitude, frequency, and phase. Strongly modulated fundamental and second harmonic pulses have been generated by operating the Mark III FEL in the regime of strong sideband growth. In this paper, we present the results of simulations and experiments for second harmonic generation with fundamental inputs from 2 to 3 {mu}m.
We present a monolithic, self-starting, all-PM, stabilized Yb-fiber laser, pulse-compressed in a hollow-core PM photonic crystal fiber, providing the 370 fs pulses of 4 nJ energy with high mode quality.
The mz8310 device support module provides support for the following record types: event, pulseCounter, pulseDelay, and pulseTrain. No driver support is needed. Up to 4 mz8310 modules are supported. Each 8310 module contains 10 channels, which are identified as signals O,...9. Each channel is individually configurable. Each mz83 10 has two Am9513 Timing Controller chips. Each Am9513 has 5 counters.
Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...
Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.
Recently a new method of controlling the pulse length of a short-pulse free-electron laser (FEL) has been developed. By modulating the synchronism between the optical and electron pulses in the FEL cavity, it was found that the output power and the micropulse length of the FEL beam oscillates at the modulation frequency. In this paper, we study theoretically the behavior of the micropulse length, both in the high loss (steady state) regime and the low loss (limit cycle) regime, when a modulated desynchronism is applied. In order to do this, we analyze the dynamics of a short-pulse FEL oscillator. The modulation frequency value plays an important role in the dynamics. We find that there is a resonantlike phenomenon between the externally applied desynchronism modulation and the limit cycle oscillation without modulation of a free-electron laser.
The detection of explosives is a notoriously difficult problem, especially at stand-off distances, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring optimal dynamic detection to exploit the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity of explosives signatures while reducing the influence of noise and the signals from background interferents in the field (increase selectivity). These goals are being addressed by operating in an optimal nonlinear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked control and probe ...
The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as cryo-permanent magnets in potential applications ...
Calculations relating to two experiments that demonstrate coherent control of preformed rubidium-85 molecules in a magneto-optical trap using ultrafast laser pulses are presented. In the first experiment, it is shown that pre-associated molecules in an incoherent mixture of states can be made to oscillate coherently using a single ultrafast pulse. A novel mechanism that can transfer molecular population to more deeply bound vibrational levels is used in the second. Optimal parameters of the control pulse are presented for the application of the mechanism to molecules in a magneto-optical trap. The calculations make use of an experimental determination of the initial state of molecules photoassociated by the trapping lasers in the magneto-optical trap and use shaped pulses consistent with a standard ultrafast laser system.
Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude ...
The advances in laser technology have made available very short and intense laser pulses which can be used to seed a high-gain single-pass free-electron laser (FEL) amplifier. With these seed pulses, a regime of the FEL interaction where the radiation evolution is simultaneously dominated by nonlinear effects (saturation) and time-dependent effects (slippage) can be explored. This regime is characterized by the propagation of a solitary wavelike pulse where the power of the optical wave grows quadratically with time, its pulse length decreases and the spectral bandwidth increases. We analyze the interplay between the field and particle dynamics of this propagation regime which was studied before and termed super-radiance. Furthermore we analyze the properties of the strong higher-order harmonic emission from this wave and its behavior when propagating in a cascade FEL. The super-radiant ...
The g factors of the 2_1"+ states in sup(84,86,88)Sr have been deduced using the thin-foil transient field technique with the field calibration of the Rutgers group. The values are g("8"4Sr)= + 0.419(47), g("8"6Sr)= + 0.273(50) and g("8"8Sr)= + 1.15(17). The mean lifetimes of the 2_1"+ states in sup(86,88)Sr were determined by the Doppler-shift attenuation method to be 2.10(22) ps and 0.219(23) ps respectively. The g factor and lifetime results are compared with shell model and interacting boson model predictions. (author).
We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.
The formation, migration and agglomeration in silicon of fluorine-vacancy complexes have been monitored by single-detector Doppler broadening spectroscopy. After electronics engineers found that fluorine ion implantation effectively eliminated the transient-enhanced diffusion of dopants in the creation of ultra-shallow junctions, a vital step in the further miniaturization of device structures, positron beams have played a pivotal role in providing an insight into the mechanisms underlying this phenomenon, being able to detect FV complexes in implanted and annealed samples. Secondary Ion Mass Spectrometry has provided complementary information on fluorine concentrations so that the nature of the F{sub m}V{sub n} complexes can be further assessed. New results on Si and SiGe structures are presented.
Maximum cross-correlation techniques have been used with satellite data to estimate winds and sea surface velocities for several years. Los Alamos National Laboratory (LANL) is currently using a variation of the basic maximum cross-correlation technique, coupled with a deterministic application of a vector median filter, to measure transverse winds as a function of range and altitude from incoherent elastic backscatter lidar data taken throughout large volumes within the atmospheric boundary layer. Hourly representations of three- dimensional wind fields, derived from elastic lidar data taken during an air-quality study performed in a region of complex terrain near Sunland Park, New Mexico, are presented and compared with results from an Environmental Protection Agency (EPA) approved laser doppler velocimeter. The wind fields showed persistent large scale eddies as well as general terrain following winds in the Rio Grande valley.
Serious complications due to coronary artery fistulae have been described. Most authors recommend early intervention at the time of diagnosis. We present a case of a fistula originating from a dilated left coronary artery and draining into the right atrium, which was diagnosed prenatally by color Doppler echocardiography. During pregnancy, the echocardiographic findings remained unchanged, and there were no signs of heart failure. After birth, the fistula was confirmed by angiography. Additionally, a persistent left superior vena cava draining into the coronary sinus and a very small ventricular septal defect were detected. The fistula was closed successfully by transcatheter coil embolization. At 17 months old the child was in good clinical condition. Prenatal diagnosis of coronary artery fistulae may be possible and may improve perinatal management and outcome. PMID:12047543
Moessbauer spectra of the Fe(III) compounds (C[sub 2]H[sub 5])[sub 4]NFeX[sub 4] (X = Cl, Br) exhibit the following anomalies above [approx] 260 K: (i) the f-factor drops with respect to normal thermal behavior, (ii) the second-order Doppler shift drops similarly, (iii) the single-line spectrum broadens, becoming asymmetric at room temperature. These phenomena are discussed in relation to possible phase transitions in these systems. (orig.)
We have determined the nuclear charge radius of 11Li by high-precision laser spectroscopy. The experiment was performed at the TRIUMF-ISAC facility where the 7Li-11Li isotope shift was measured in the 2s to 3s electronic transition using Doppler-free two-photon spectroscopy with a relative accuracy better than 10 5. The accuracy reached in previous experiments on the other lithium isotopes was improved. Most of the isotope shifts measured in the experiment are due to difference in the mass of the nuclei but small contributions are produced by the change in proton distribution, QED and relativistic effects have to be taken into account as well. By comparing the experimental results with sophisticated atomic calculations of the mass dependent effect the nuclear charge radii of the lithium isotopes are found to decrease monotonically from 6Li to 9Li while the nuclear charge radius of 11Li is about 11% larger than that of 9Li.
Mixed convection in a rectangular channel (width/height = 2) with bottom-heated and top-cooled sections is studied by laser Doppler anemometry in nitrogen at Ra = 22,200 and Re = 18.75, 36, and 54. At the lower Re values, symmetry breaking is observed in steady but spatially oscillating flows that prevail over a certain distance from the leading edge of the differentially heated section. Further downstream, unsteady flows are found even for Re = 18.75. Numerical models are used to investigate the effects of adiabatic, conducting (with a conductive-convective heat transfer coefficient), and perfectly conducting side walls; channel tilts and Prandtl number dependence. Good agreement between calculations and experiment is obtained for longitudinal convective roll velocities. The transverse velocities are found to be independent of Re.
The g factors of the 2/sub 1//sup +/ states in sup(84,86,88)Sr have been deduced using the thin-foil transient field technique with the field calibration of the Rutgers group. The values are g(/sup 84/Sr)= + 0.419(47), g(/sup 86/Sr)= + 0.273(50) and g(/sup 88/Sr)= + 1.15(17). The mean lifetimes of the 2/sub 1//sup +/ states in sup(86,88)Sr were determined by the Doppler-shift attenuation method to be 2.10(22) ps and 0.219(23) ps respectively. The g factor and lifetime results are compared with shell model and interacting boson model predictions.
Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.
The electron cyclotron resonance layer in a tokamak, {omega}={omega}{sub c}(r), is not accessible by the extraordinary wave from the low field side, because it is shielded by a cutoff layer. However, a X-mode launched with a nonzero toroidal angle propagates at the cutoff parallel to the magnetic field and has a circular polarization. Therefore it can already at the cutoff layer interact efficiency with electrons via the Doppler shifted resonance. The driven current can be substantially higher than that driven by the second harmonic X-mode. The applicability of this current drive scheme is limited to rather low values of {omega}{sub p}{sup 2}/{omega}{sub c}{sup 2}, but may be of interest for high magnetic field devices. (author)
MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).
A new subcarrier combining technique is proposed for MC -CDMA receiver in mobile Rayleigh fading channel. It exploits the structure formed by repeating spreading sequences of users on different subcarriers to simultaneously suppress multiple access interference (MAI) and provide implicit channel tracking without any knowledge of the channel amplitudes or training sequences. This is achieved by adaptively weighting each subcarrier in each symbol period by employing a simple gradient descent algorithm to meet the constant modulus (CM) criterion with judicious selection of step-size. Improved BER and user capacity performance are shown with similar complexity in order of O(N) compared with conventional maximum ratio combining and equal gain combining techniques even under high channel Doppler rates.
A fundamental Doppler-like but asymmetric wave effect that shifts received signals in frequency in proportion to their respective source distances, was recently described as means for a whole new generation of communication technology using angle and distance, potentially replacing TDM, FDM or CDMA, for multiplexing. It is equivalent to wave packet compression by scaling of time at the receiver, converting path-dependent phase into distance-dependent shifts, and can multiply the capacity of physical channels. The effect was hitherto unsuspected in physics, appears to be responsible for both the cosmological acceleration and the Pioneer 10/11 anomaly, and is exhibited in audio data. This paper discusses how it may be exploited for instant, passive ranging of signal sources, for verification, rescue and navigation; incoherent aperture synthesis for smaller, yet more accurate radars; universal immunity to jamming or interference; and precision frequency scaling of ...
A comparative core design study is performed on Pb-Bi cooled reactors with forced and natural convection (FC and NC) cooling. Major interests of the study are core performance and core safety features. The designed core concepts with nitride fuel achieve reasonable breeding capability. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features to withstand unprotected events due to negative reactivity feedback by Doppler effect, control rod drive line expansion, etc. These results lead to a conclusion that both of concepts have possible capability as one of future promising core concepts. A FC cooling core concept has more advantage if fuel recycle viewpoint is emphasized. (author)
We present a single solid-state laser system to cool, coherently manipulate and detect $^{25}$Mg$^+$ ions. Coherent manipulation is accomplished by coupling two hyperfine ground state levels using a pair of far-detuned Raman laser beams. Resonant light for Doppler cooling and detection is derived from the same laser source by means of an electro-optic modulator, generating a sideband which is resonant with the atomic transition. We demonstrate ground-state cooling of one of the vibrational modes of the ion in the trap using resolved-sideband cooling. The cooling performance is studied and discussed by observing the temporal evolution of Raman-stimulated sideband transitions. The setup is a major simplification over existing state-of-the-art systems, typically involving up to three separate laser sources.
In this paper, molecular quantum computation is numerically studied with the quantum search algorithm (Grover's algorithm) by means of optimal control simulation. Qubits are implemented in the vibronic states of I_2, while gate operations are realized by optimally designed laser pulses. The methodological aspects of the simulation are discussed in detail. We show that the algorithm for solving a gate pulse-design problem has the same mathematical form as a state-to-state control problem in the density matrix formalism, which provides monotonically convergent algorithms as an alternative to the Krotov method. The sequential irradiation of separately designed gate pulses leads to the population distribution predicted by Grover's algorithm. The computational accuracy is reduced by the imperfect quality of the pulse design and by the electronic decoherence processes that are modeled by the non-Markovian ...
The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak ...
Sodium-dependent high-affinity choline uptake was measured in various regions of the brains of rats irradiated for 45 min with either pulsed or continuous-wave low-level microwaves (2,450 MHz; power density, 1 mW/cm2; average whole-body specific absorption rate, 0.6 W/kg). Pulsed microwave irradiation (2-microseconds pulses, 500 pulses/s) decreased choline uptake in the hippocampus and frontal cortex but had no significant effect on the hypothalamus, striatum, and inferior colliculus. Pretreatment with a narcotic antagonist (naloxone or naltrexone; 1 mg/kg i.p.) blocked the effect of pulsed microwaves on hippocampal choline uptake but did not significantly alter the effect on the frontal cortex. Irradiation with continuous-wave microwaves did not significantly affect choline uptake in the hippocampus, striatum, and hypothalamus but decreased the uptake in the frontal cortex. The ...
A high power Free-Electron Laser (FEL) has lased at a wavelength of 22 #mu#m at the Japan Atomic Energy Research Institute (JAERI). The maximum power on a macro-pulse average is 1.7 kW, and it corresponds to an FEL energy of 160 #mu#J/micro-pulse. Extraction efficiency from the electron beam to the FEL radiation was measured to be 5.3% by an energy analyzer, when the maximum FEL power was coupled out. The rms wavelength spread was measured to be 4.6% at the same time. The extraction efficiency, in general, has a maximum value near the zero detuning length of an optical cavity, where (in contrast) the single-pass gain becomes smallest. A high peak current and a long macro-pulse duration are therefore indispensable for realizing high efficiency. The electron beam energy is 16.5 MeV, and the average current is 5.3 mA at a micro-pulse repetition rate of 10.4 MHz. The macro-pulse ...
The US Department of Energy`s Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also ...
The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and ...
Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.
A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.
The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.
Measurements of low-energy (#approx#10"- "1"0 J) femtosecond laser pulse durations have been carried out on the basis of second-order autocorrelation function analysis. The scheme of non collinear second harmonic generation realized in KDP crystal has been used for increasing of the measurement contrast and accuracy. Proposed scheme can be used for measurements in wide enough ranges of laser pulse durations (from tens femto seconds to hundreds picoseconds) and energies. (authors)
Eight cross spiders (Araneus diadematus) were exposed overnight (16 h) during web-building activity to pulsed 9.6-GHz microwaves at average power densities of 10, 1, and 0.1 mW/sq. cm. (estimated SARs 40, 4, and 0.4 mW/g). Under these conditions, 9.6-GHz pulsed microwaves did not affect the web-spinning ability of the cross spider.
There is increasing demand to functionalize meso- and nano-porous materials by coating and make the porous substrate biocompatible or environment friendly. However, coating on a meso-porous substrate poses great challenges, especially if the pore aspect ratio is high. In the current work the pulsed laser deposition (PLD) method is used for coating Ni{sub 3}Al-based meso-porous membranes with diamond-like carbon (DLC) layers of high thickness homogeneity and adhesion. (orig.)
We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.
The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...
A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}
... main in this state only for 10-8 secs., after which they decay to the meta- stable state (fluorescent level) because of spontaneous radiation or other ...
... at compositions below -AlP 4 the films were still unstable, hydrolysing in room air, and the long term stability of higher aluminium phosphides is in ...
This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N{sub 2} : H{sub 2}) and pulsed ratio (pulse on/off time ratio)
This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N_2 : H_2) and pulsed ratio (pulse on/off time ratio).
To measure electron reactions on a picosecond timescale the investigators developed a picosecond pulse-conductivity technique, which makes use of the electron fine-structure pulses of our LINAC (pulse width 25 vs FWHM) to produce excess electrons and now detects changes in sample conductance under optimum conditions with an instrumental response of 18 ps. This resolution is in agreement with a theoretical estimate. This technique has been successfully applied to study excess electron reactions in solvents covering a mobility range from 0.24 to 100 cm/sup 2/V/sup -1/s/sup -1/; extension to lower mobility liquids seem possible.
A three-dimensional numerical study is performed to explore the effect of pulsed spanwise-periodic surface thermal perturbation (also denoted as thermal bump) in a Mach 1.5 flat plate laminar boundary layer. A high-resolution upwind-biased Roe method is used with the compressive Van Leer harmonic limiter on a suitably refined mesh. The dependence of flow stability characteristics on the variation of thermal bump geometry (shape and dimension) and pulsing properties (disturbance amplitude and frequency) is assessed. It is shown that the finite-span thermal bumps generate streamwise vortices. When the thermal bump is pulsed, vortex shedding is observed, and the streamwise vorticity grows with the downstream distance. Analysis of the integrated disturbance energy indicates that the streamwise...
A flowing carbon dioxide laser was operated at low pressures up to 4 torr. Excitation of the laser was provided using various combinations of direct current (DC), pulsed microwave, and continuous wave (CW) microwave excitation. The microwaves were in the 2.45 GHz band and were coupled into the gas using a slow-wave interdigital transmission line. Laser output of 25 milliwatts (mw) was achieved using a DC discharge only. A combination of a DC discharge and pulsed microwaves doubled the output and resulted in some modulation. Changing the laser gas mixture and pulsed microwave field characteristics allowed some flexibility in the modulation. Lasing was not achieved with excitation from the CW microwaves alone due to the formation of localized discharges. Using pulsed microwaves to sustain the discharge and CW microwaves to pump the laser, a quasi-CW output of 55 mw was achieved.
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries
In the rf-driven free-electron laser (FEL) at the Los Alamos National Laboratory, there are two pulsed-power rf modulators as sources for two tandem, side-coupled 20-MeV linear accelerators. The rf power used to control the cavity fields is supplied by two 5.5-MW modulating anode klystrons operating at a center frequency of 1300.2 MHz. The modulation of the 125 kV klystron is achieved by using a triode switch tube that provides a pulse width up to 300 ..mu..s and a pulse repetition rate up to 10 Hz. This paper describes the present configuration of these two duplicate systems and presents plans for meeting the requirements of future rf FEL experiments at Los Alamos. 12 refs., 5 figs.
Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
Recently there has been growth, in interest in non-equilibrium interaction of half-period long optical pulses with matter. To date the optical pulses have been produced by chopping out a half-period long segment from a longer pulse using a semiconductor switch driven by a femtosecond laser. In this paper we present new methods for producing tunable ultra-short optical pulses as short as half an optical period using a free-electron laser driven by electron bunches with a duration a fraction of an optical period. Two different methods relying on the production of coherent spontaneous emission will be described. In the first method we show that when a train of ultra-short optical pulses as short as one half period. We present calculations which show that the small signal gain is unimportant in the early stages of radiation build up in the cavity when the startup process is dominated by ...
We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.
Electrically triggered action potentials in the giant alga Chara corallina are associated with a transient rise in the concentration of free Ca(2)+ in the cytoplasm (Ca(2)+(cyt)). The present measurements of Ca(2)+(cyt) during membrane excitation show that stimulating pulses of low magnitude (subthreshold pulse) had no perceivable effect on Ca(2)+(cyt). When the strength of a pulse exceeded a narrow threshold (suprathreshold pulse) it evoked the full extent of the Ca(2)+(cyt) elevation. This suggests an all-or-none mechanism for Ca(2)+ mobilization. A transient calcium rise could also be induced by one subthreshold pulse if it was after another subthreshold pulse of the same kind after a suitable interval, i.e., not closer than a few 100 ms and not longer than a few seconds. This dependency of Ca(2)+ mobilization on single and double pulses ...
Electrically triggered action potentials in the giant alga Chara corallina are associated with a transient rise in the concentration of free Ca2+ in the cytoplasm (Ca2+cyt). The present measurements of Ca2+cyt during membrane excitation show that stimulating pulses of low magnitude (subthreshold pulse) had no perceivable effect on Ca2+cyt. When the strength of a pulse exceeded a narrow threshold (suprathreshold pulse) it evoked the full extent of the Ca2+cyt elevation. This suggests an all-or-none mechanism for Ca2+ mobilization. A transient calcium rise could also be induced by one subthreshold pulse if it was after another subthreshold pulse of the same kind after a suitable interval, i.e., not closer than a few 100 ms and not longer than a few seconds. This dependency of Ca2+ mobilization on single and double pulses can be simulated by a ...
Effect of Abdominal Active Can on DFTs. Introduction: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. Methods and Results: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ...
on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...
Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)
... The three meteorological rocket systems, in order of ... IC3 and IC4 divides the incoming clock pulses f ... at the junction of the temperature sensor and R ...
The heating and current drive systems are being developed to support long pulse, high {beta}, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.
The heating and current drive systems are being developed to support long pulse, high #beta#, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.
... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...
Effects of 2450-MHz circularly polarized microwave irradiation on central nervous system functions were studied. Pulsed (microsecond, 500 pps) microwaves decreased high-affinity sodium-dependent choline uptake in the hippocampus and frontal cortex of the rat. The effect on hippocampal choline uptake was blocked by pretreatment with narcotic antagonists. Continuous-wave microwaves of the same power density decreased choline uptake in the frontal cortex only. Furthermore, it was found that the effects of pulsed microwaves on central cholinergic activity are classically conditionable to cues in the exposure environment. The hypothesis that some of the neurological effects of pulsed microwave irradiation are caused by its effect on the auditory system was investigated. Effects of pink noise and pulsed microwaves were compared.
During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-#mu#m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.
During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-{mu}m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.
AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.
In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry
Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). ...
The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The focus of this work is ...
Detonators are used to convert electrical or other energy into an explosive output. This output can then be used to initiate further explosive charges. To aid in the development of explosive systems, it is important to characterize the output of detonators, in particularly the pressure produced. Recent advances over the last five years in high-speed digitizing oscilloscopes and high-bandwidth photodiodes, driven primarily by the telecommunications industry, have enabled the development of a new type of interferometer for measuring high velocities, such as those found in detonics experiments. The Photonic Doppler Velocimeter (PDV) can be visualized as a fiber-based Michelson interferometer. The light from a single-mode fiber laser at 1550 nm is passed through a circulator, which acts to separate bi-directional light. The beam is then reflected via free-space optics off the surface of interest, and then focused back into the same fiber. This reflected light is then ...
The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)
An experimental study of second harmonic generation in a copper-vapor pulsed laser with an ADP crystal is presented. The ratio of the conversion into the second harmonic is found to depend on the average power of the exciting radiation. The maximum conversion ratio was 8.5%. Thermal self-defocusing is the main obstacle to obtaining high average powers at the double frequency.
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
Saturation of the absorption of hot CO/sub 2/ by 1.6 ns P(18) and P(20) laser pulses at 10.6 ..mu..m has been measured. Coherent propagation calculations with no fitting parameters are in good agreement with the data and are consistent with a substantial hot-band contribution to the P(20) saturation.
The author is exploring the efficiency of pulsed plasma processing in the removal of nitrogen dioxide, nitrogen oxide, and other pollutants. This process uses an electrical discharge to create chemical radicals from air molecules. These radicals can react with pollutants and form harmless compounds. Additives such as hydrocarbons are also used to improve the efficiency of the removal. The efficient removal of nitrogen dioxide has required the presence of dilute aqueous solution of ammonia.
Based on the nonlinear dispersion relation of electromagnetic wave in relativistic plasma, the nonlinear controlling equation for linearly polarized mode is obtained using Karpman's method. The modulation instability of intense laser pulse propagating through relativistic plasma is analyzed and the modulation instability growth rate as a function of perturbation wave number for laser beam propagating through relativistic plasma is given. (authors)
This paper summarizes a method to evaluate the possible effects of magnetohydrodynamic-electromagnetic pulse (MHD-EMP) on power systems. This method is based on the approach adapted to study the impact of geomagnetic storms on power systems. The paper highlights the similarities and differences between the two phenomena. Also presented are areas of concern which are anticipated from MHD-EMP on the overall system operation. 12 refs., 1 fig.
The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.
The paper presents a description of the physical processes governing the variations of the pulse rise-time which occur during the operation of the proportional counter and are due to varying either the count rate or the applied voltage. On the basis of the rise-time concept the differences in the count rate effect observed in various types of proportional counters are discussed.
Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)
This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The ...
Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.
An analytic solution is obtained for the equations of resonance coherent SRS by neglecting the population of the final level of the Raman transition for the systems with the active-medium length that is smaller than the wavelength of the incident light. For the extended systems, a numerical solution is obtained. The energy distribution of the Stokes pulses is found. The large-scale (about 100%) fluctuations of the Stokes radiation energy were observed in the case of unsaturated amplified spontaneous emission. (nonlinear optical phenomena)
Isotopically selective IR multiphoton dissociation of molecules (SF_6, CF_3I) in a pulsed gas-dynamic flow interacting with a solid surface was studied for the first time. A noticeable (severalfold) increase in the yield of products (compared to excitation of molecules in an unperturbed flow) without a substantial decrease in the selectivity of the process was observed. Possible reasons for the effect are discussed. (laser applications and other topics in quantum electronics)
The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the spent electron beam ...
We have developed a novel insulator concept that involves the use of alternating layers of conductors and insulators with periods less than 1 mm. We have demonstrated that these structures perform 2 to 5 times better than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present new testing results showing exceptional behavior at DC, with gradients in excess of 110kV/cm in vacuum.
A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.
Implementation of quantum logical gates for multilevel systems is demonstrated through decoherence control under the quantum adiabatic method using simple phase modulated laser pulses. We make use of selective population inversion and Hamiltonian evolution with time to achieve such goals robustly instead of the standard unitary transformation language. (letter to the editor)
In this paper, finite-difference time-domain method is used to research the transient electromagnetic pulse (EMP) coupling to the cylinder object which is shielded in another shielding cavity with a hole numerically. The different coupling effectiveness of three transient EMP is simulated. The distribution of the electric field in the shielding cavity and the current on the cavity are researched. The shielding effectiveness is evaluated. (authors)
To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the remaining five the cyst ...
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by two radiologists. ...
Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...
Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to determine the strength ...
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
The alloying of steel surface with aluminum (Al) using Microsecond-pulsed Intense Electron Beams (MIEB-Al) was developed and optimized in order to be used for improving the corrosion resistance of the 316, 1.4970 and T91 steels, exposed to liquid Pb and Pb-Bi-eutectic. The procedure consists in two steps: (i) coating the steel surface with Al or an Al-containing alloy layer and (ii) melting the coating layer and the steel surface layer using intense pulsed electron beam. In order to cover the steel surface with an homogeneous and crack-free Al-alloyed layer, the following experimental conditions are required: Al coating thickness range 5-10mm, electron kinetic energy 120keV; pulse duration 30ms; energy density 40-45J/cm2; number of pulses 2-3. Using the mentioned procedure, the corrosion r...
We present computer modeling along with experimental data on the formation of sharp conical tips on silicon-based three-layer structures that consist of a single-crystal Si layer on a 1 {mu}m layer of silica on a bulk Si substrate. The upper Si layers with thicknesses in the range of 0.8-4.1 {mu}m were irradiated by single pulses from a KrF excimer laser focused onto a spot several micrometers in diameter. The computer simulation includes two-dimensional time-dependent heat transfer and phase transformations in Si films that result from the laser irradiation (the Stefan problem). After the laser pulse, the molten material self-cools and resolidifies, forming a sharp conical structure, the height of which can exceed 1 {mu}m depending on the irradiation conditions. We also performed computer simulations for experiments involving single-pulse irradiation of bulk silicon, reported by other groups. We discuss conditions under ...
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to ...
This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or ...
Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO_2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water was waved by corona ...
Up to now the long range filaments have been considered as a balance between Kerr focusing and defocusing by plasma generation in the nonlinear focus. However, it is difficult to apply the above explanation of filamentation in far-field zone. There are basically two main characteristics which remain the same at these distances - the super broad spectrum and the width of the core, while the power in a stable filament drops to the critical value for self-focusing. At such power the plasma and higher-order Kerr terms are too small to prevent self-focusing. We suggest here a new mechanism for stable soliton pulse propagation in far-away zone, where the power of the laser pulse is slightly above the critical one, and the pulse comprises super-broad spectra. For such pulses the diffraction is not paraxial and an initially symmetric Gaussian pulse takes parabolic form at several ...
Pulses are rich in nutrients. The existence of anti-nutritional components and the length of time required for preparation have, however, limited their frequency of use compared to recommended intake levels. Anti-nutritional components in pulses can be largely removed by heat treatment. Additionally pre-treatment of pulses with heat and processing of seeds into flour could further enhance their use by decreasing processing and preparation times. In this study, trypsin inhibitor activity, functional properties, and microstructural characteristics of flours prepared from different varieties of lentil, chickpea, and pea as affected by roasting and boiling were evaluated. Both thermal treatments resulted in significant reduction (p<0.05) in trypsin inhibitor activity ranging from -95.6% to -37...
Improved biosorption of uranium by Kluyveromyces marxianus IMB3 biomass was achieved by increasing the electric field strength of delivered pulses from 1.25kV/cm to 2.5kV/cm. Although this had little or no effect on the maximum biosorption capacity (q(max)), at low concentrations of uranium the amount bound to the biomass increased from 70 to 140mg uranium/g biomass. Significant increases in the maximum biosorption capacities (119-180 mg uranium/g biomass) were observed when the pulse field strength was increased from 2.5kV/cm to 3.25kV/cm. (Author).
The production of retrograde amnesia (RA) upon electron-beam exposure was investigated. RA production was evaluated using a single-trial avoidance task for 10, 1, and 0.1 microsecond pulsed exposures. The dose-response curve obtained at each pulse duration showed significant RA production. The most effective dose range was 0.1-10 rad at a dose rate of 1,000,000 rad/sec. By employing a 10 rad (1,000,000 rad/s) pulse, a memory loss of the events occurring in the previous 4 sec was demonstrated. The conclusion was that the RA effect might be due to sensory system activation which provided a novel stimulus that masked previous stimuli.
The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).
The Pulsed Lepton Source (PLS) project opens some exciting possibilities for muon and neutrino physics . The PLS would use the 0.25 4s proton pulses from the upgraded Proton Storage Ring (PSR) at LAMPF to create short, intense bursts of muons and neutrinos. The neutrino beam would be used for a few fundamentally important weak interaction physics experiments. The muon beams would find a wide variety of applications in both fundamental and applied'' muon physics areas. After a brief discussion of the physical layouts of the PSR and the proposed PLS in Sec. 2 and muon area in Sec. 3, we note some of the muon physics experiments and areas that could advantageously be addressed at the PLS in Secs. 4 and 5, and conclude in Sec. 6.
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
Conductive TiN/Si_3N_4 ceramic composites were processed by electrical discharge machining (EDM) and their microstructure and conductivity were investigated. The whole process of tool electrode wear is evaluated by sinker-EDM. The machined surfaces of TiN/Si_3N_4 ceramic composites were examined by scanning electron microscopy (SEM) and profilometry to determine the surface finish. The electrode wear rate of brass is higher than copper electrode for all EDMed tests. The surface texture was found to have greater dependence on pulse energy. It was observed that the sinker-EDM at higher pulse energy caused severe microdamage in the surface. The surface roughness (Ra) values also increase with increasing pulse energy.
Ferroelectric disks, coated with proper electrodes, can easily produce a dense plasma cloud when excited with a high-voltage pulse. This plasma can be a source of either electrons or ions depending on the sign of the extracting field set in front of the disk. We present the behavior of the disks operating at high frequency as emitters of both electrons and ions in two experimental configurations: (a) without and (b) with two screening grids. These two screening grids are inserted when the plasma must be confined within the cathode region. The system is capable of providing ion pulses of a few hundred milliamperes, whose length can range from a hundred nanoseconds to dozen microseconds. The electron pulses of energetic electrons have typically an amplitude higher than a couple of amperes. Tests at MHz repetition rate were positive as for stable operation.
The nature of the `inner engine' that accelerate and collimate the relativistic flow at the cores of GRBs is the most interesting current puzzle concerning GRBs. Numerical simulations have shown that the internal shocks' light curve reflects the activity of this inner engine. Using a simple analytic toy model we clarify the relations between the observed $ \\gamma $-rays light curve and the inner engine's activity and the dependence of the light curves on the inner engine's parameters. This simple model also explains the observed similarity between the observed distributions of pulses widths and the intervals between pulses and the correlation between the width of a pulse and the length of the preceding interval. Our analysis suggests that the variability in the wind's Lorentz factors arises due to a modulation of the mass injected into a constant energy flow.
We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.
A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.
One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.
A pillbox RF output window was developed for the L-band pulsed klystron for the Japanese Hadron Project (JHP) 1-GeV proton linac. The window was designed to withstand a peak RF power of 6 MW, where the pulse width is 600 {mu}sec and the repetition rate is 50 Hz. A high power model was fabricated using an alumina ceramic which has a low loss tangent of 2.5x10{sup -5}. A high power test was successfully performed up to a 113 kW RF average power with a 4 MW peak power, a 565 {mu}sec pulse width and a 50 Hz repetition rate. By extrapolating the data of this high power test, the temperature rise of the ceramic is estimated low enough at the full RF power of 6 MW. Thus this RF window is expected to satisfy the specifications of the L-band Klystron. (author).
A voice activated garage door opener was designed for a handicapped person to open a garage door without assistance. This design uses speech recognition of one word. The activating word that was chosen is "up". The frequency spectrum of "up" was captured on a soundboard and is the basis of this design. Filters are used to pick out three frequency bands in this spectrum. The output signals from these filters are then compared to three threshold voltages using voltage comparators. If the output signals from the filters are above the threshold voltages, the comparators go high. Monostable multivibrators are used on the output of the comparators to lengthen the high pulses. When all of the pulses from the monostable multivibrators are high at the same time, an AND gate output goes high. This high pulse activates the door opener. PMID:8329601
The design and operating principle of a small (50 mm in diameter and 100 mm in height) ???-73C vacuum spark gap are described. It is shown that it can be efficiently switched using a control circuit with a low (?900 V) supply voltage, which is based on an inductive energy storage and a diode opening switch that forms a high-voltage igniting pulse with a rise time of nanosecond duration. The ???-73C switching process is investigated at different rise times of igniting voltage pulses and different igniting current amplitudes. The results of tests of the spark gap operating in regimes of switching current pulses with an amplitude of 12 kA and a rise time of 800 ns are presented.
This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.
One of the main challenges for a high energy {gamma}{gamma} collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
One of the main challenges for a high energy #gamma##gamma# collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are described. copyright 1997 American Institute of Physics.
SommarioScopo In questo studio riportiamo i dati relativi all'ablazione percutanea con Radiofrequenza (RF) di HCC e trombosi neoplastica dei vasi portali. Pazienti e metodi Dieci pazienti (pz) cirrotici, 7 maschi e 3 femmine, eta media 68 anni, con 10 noduli di HCC e trombosi neoplastica dei vasi portali sono stati sottoposti ad ablazione percutanea con RF del trombo neoplastico e dell'HCC. La RF veniva ritenuta efficace quando alla TC con mdc si osservava la necrosi completa dell'HCC e al Color Doppler si osservava la ricanalizzazione completa dei vasi portali. Risultati La necrosi completa dell'HCC e la ricanalizzazione completa dei vasi portali si osservava in 7 (70%) dei 10 pazienti. Nei rimanenti 3 (30%) la necrosi dell'HCC e la ricanalizzazione dei vasi portali non risultavano comple...
This work presents an experimental and numerical study of pulsated Dean flow, three-dimensional pulsatile flow in a curved pipe. The numerical study is performed by CFD code (Fluent 6) in which a pulsated velocity field is imposed as an inlet condition. The experimental setup involves principally a 'Scotch-yoke' pulsatile generator and a 90o bend. Laser Doppler Velocimetry (LDV) measurements have shown that the Scotch-yoke generator produces pure sinusoidal instantaneous mean velocities with a mean deviation of 3%. Visualizations by laser-induced fluorescence (LIF) and velocity measurements, coupled with the numerical results, have permitted analysis of the evolution of the swirling secondary flow structures that develop along the bend during the pulsation phase. These measurements were made for a range of stationary Reynolds number (300?Rest?1200), frequency parameter (1??=r0(?/?)1/2max,osc/Ust). We observe satisfactory agreement between the numerical and ...
This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due to several experimental difficulties were not as successful. The photorefractive ...
Abstract in english We hypothesized that chronic oral administration of the phosphodiesterase-5 inhibitor sildenafil could improve the exercise capacity and pulmonary hemodynamics in patients with pulmonary arterial hypertension (PAH) on the basis of previous short-term studies. We tested this hypothesis in 14 subjects with PAH, including seven patients with the idiopathic form and seven patients with atrial septal defects, but no other congenital heart abnormalities. Patients were subjected (more) to a 6-min walk test and dyspnea was graded according to the Borg scale. Pulmonary flow and pressures were measured by Doppler echocardiography. Patients were given sildenafil, 75 mg orally three times a day, and followed up for 1 year. Sildenafil therapy resulted in the following changes: increase in the 6-min walk distance from a median value of 387 m (range 0 to 484 m) to 462 m (range 408 to 588 m; P
The macroscopic rotation of plasma in a toroidal containment device is an important feature of the equilibrium. Toroidal and polidal rotation in the high-beta tokamak Torus II is measured experimentally by examining the Doppler shift of the 4685.75 A He II line emitted from the plasma. The toroidal flow at an average velocity of 1.6 x 10/sup 6/ cm/sec, a small fraction of the ion thermal speed, moves in the same direction as the toroidal-plasma current. The poloidal flow follows the ion diamagnetic current direction, also at an average speed of 1.6 x 10/sup 6/ cm/sec. In view of certain ordering parameters, the toroidal flow is compared with predictions from neoclassical theory in the collisional, Pfirsch-Schluter regime. The poloidal motion, however, results from an E x B drift in a positive radial electric field, approaching a stable ambipolar state. This radial electric field is determined from theory by using the measured poloidal velocity. Mechanisms for the ...
The macroscopic rotation of plasma in a toroidal containment device is an important feature of the equilibrium. Toroidal and poloidal rotation in the high beta tokamak Torus II is measured experimentally by examining the Doppler shift of the 4685.75 A He II line emitted from the plasma. The toroidal flow at an average velocity of 1.6 x 10/sup 6/ cm/sec, a small fraction of the ion thermal speed, moves in the same direction as the toroidal plasma current. The poloidal flow follows the ion diamagnetic current direction, also at an average speed of 1.6 x 10/sup 6/ cm/sec. In view of certain ordering parameters, the toroidal flow is compared with predictions from neoclassical theory in the collosional, Pfirsch-Schluter regime. The poloidal motion, however results from an E x B drift in a positive radial electric field, approaching a stable ambipolar state. This radial electric field is determined from theory by using the measured poloidal velocity. Mechanisms for the ...
Swirling flow in a direct injection diesel engine was measured by a laser doppler velocimeter. Piston cavity diameter and top clearance volume were changed as factors affecting swirling flow to study the distribution of swirling flow speed. When using the same intake port and changing the opening ratio of piston cavity, the distribution of swirling flow speed was different by the cavity during intake process but these agree just after opening intake valve and then become again different by cavity. When increasing top clearance and decreasing compression ratio, the axial symmetry of flow during commpression process increases. When changing piston cavity, and also when changing intake port, the mean swirling ratio in inside and outside areas of combustion chamber has common tendency to increase and decrease respectively. The mean swirling flow in the combustion chamber may be capable to be predicted by devising a model which can describe this tendency. 3 refs., 9 ...
Swirling speed in a direct injection diesel engine was measured by a laser doppler velocimeter. Intake port geometry and engine speed were changed as factors affecting the swirling flow to study the distribution of swirling flow speed. The distribution of swirling flow speed changes complicatedly owing to axial nonsymmetry during intake process but becomes simple shape of axial symmetry during compression process after closing intake valve. But if this is assumed as the rigid swirl shape, the difference due to each intake port cannot be expressed but also large error may be possible to appear close to the cylinder wall. The distribution of swirling flow speed during compression process changes similarly, nearly proportinal to engine speed. But the similarity is higher at the middle period in compression process than at the end period in compression period. Axial distribution of local swirling ratio during compression process is nearly uniform. 8 refs., 10 figs., 1 ...
Electrostatic wave measurements from the Active Magnetospheric Particle Tracer Explorer Ion Release Module have been used to investigate the wave modes and their possible generation mechanisms in the Earth's bow shock and magnetosheath. It is demonstrated that electrostatic waves are present in the bow shock and magnetosheath with frequencies above the maximum frequency for Doppler-shifted ion acoustic waves, yet below the plasma frequency. Waves in this frequency range are tentatively identified as electron beam mode waves. Data from 45 bow shock crossings are then used to investigate possible correlations between the electrostatic wave properties and the near-shock plasma parameters. The most significant relationships found are anticorrelations with Alfven Mach number and electron beta. Mechanisms which might produce electron beams in the shock and magnetosheath are discussed in terms of the correlation study results. These mechanisms include acceleration by the ...
To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. A comparative design study is performed on Lead-Bismuth cooled reactors with forced and natural convection cooling. Eliminating an intermediate cooling system makes the heat transport system simple and can decrease the amount of the weight of NSSS. Based on the estimation of the amount materials, the plant internal load etc., a construction cost of these plants are evaluated approximately 2/3 times of that of LWRs at present. And, the nitride fuel makes breeding ratio of 1.2 with 150 GWd/t of burnup. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features to withstand unprotected events due to negative reactivity ...
SommarioNei Paesi occidentali il rischio di malattie cardiovascolari e notevolmente aumentato negli ultimi decenni. Di pari passo, il miglioramento prognostico delle malattie cardiovascolari, l'invecchiamento e l'aumento della vita media della popolazione generale stanno rivelando un crescente numero di casi di malattia renale cronica d'origine vascolare. E del tutto plausibile pensare che nei prossimi anni il numero di pazienti anziani con malattia vascolare aterosclerotica, che sara inserito nei programmi di dialisi cronica, aumentera rapidamente. Questo fara lievitare in modo drammatico i costi sociali ed economici della dialisi configurando una vera emergenza clinica. In questo scenario epidemiologico, la diagnosi precoce della malattia ischemica cronica del rene e la definizione di nu...
Adenosine triphosphate (ATP) is an alternative to dipyridamole or adenosine in thallium-201 myocardial scintigraphy. However, the optimal dose of ATP has not been determined. A Doppler guide wire study showed the coronary flow velocity at a dose of 0.15 mg/kg of ATP was equal or higher than that at 0.14 mg/kg of adenosine or 0.56 mg/kg of dipyridamole. ATP was given intravenously to 67 patients with coronary artery disease at 0.15 mg/kg/min for 6 min. Thallium-201 was injected at 3 min, followed by immediate and delayed (3 hrs) tomographic imaging. There was no serious side effect during examination, although chest pain (26%), dyspnea (17%), and flushing (33%) were common. The sensitivity and specificity to detect coronary artery disease were 98 and 100%, respectively. The sensitivity to detect left anterior descending artery, left circumflex artery, and right coronary artery lesions was 94, 59 and 77%, respectively. ATP loading thallium-201 scintigraphy provides ...
Haemangiomas usually develop within the first few weeks of life, most regressing spontaneously before the age of 7 years. Some may ulcerate or compromise a vital function, in which case systemic corticosteroids, surgery or radiotherapy may be helpful. All of these treatment modalities are associated with significant morbidity. Treatment with the 585 nm flashlamp pulsed dye laser is safe and effective in the management of superficial vascular malformations. We report seven patients, under 12 months of age, who presented with proliferative haemangiomas, causing functional impairment. Ulcerated lesions were present in four patients. The patients were treated with the 585 nm pulsed dye laser (fluences 7.0-9.25 J/cm2), at intervals of 4-8 weeks. All of the lesions showed a significant reduction in size, together with improvement in the colour and integrity of the overlying skin. Treatment with the 585 nm pulsed dye laser should ...
Using standard brass alloy samples, an approach to reduce the laser-induced breakdown spectroscopy measurement uncertainty was tested and proved. Two important parameters for plasma characterization, the plasma temperature and the electron density, were applied to minimize the signal uncertainties due to uncontrollable experimental parameter variations. Results show that for the pulse-to-pulse analysis, the signal fluctuations can be significantly reduced by utilizing the plasma characteristic information. The major source for the single pulse fluctuations is the redistribution of the characteristic line at different temperatures according to the Boltzmann distribution under LTE. The change of the degree of ionization also contributes to the signal fluctuations. For the multi-pulse analysis, due to the nonlinear relationship between the plasma temperature and the line intensity, it is not applicable to utilize the Boltzmann ...
Analysis of the pulsed-field gel electrophoretic profiles of 82 pneumococcal isolates with reduced susceptibility to ciprofloxacin (RSC) and of 90 co-occurring susceptible isolates indicates a considerable...Full Text Available
In systems of fast decimal counters, there are three problems to be resolved: to study a bistable having a short switching time, to form with the aid of three bistables a circuit divisible by 5, and to normalize the input pulses. The solutions to these problems for the nonsecond scaler are presented. (J.S.R.)
The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...
Technologies for materials, processes, and manufacturing that will provide safe, .... advanced energy conversion techniques, and pulsed inductive and ... duration antimatter storage and transportation, and methods for utilizing ...... EVA systems can be found in the EVA Technology Roadmap of the EVA Project Plan. ...
The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which enhances the neutron exposure capabilities over those of the former ACPR Facility.
The traveling-wave mode in ring lasers is achieved by two methods: by a reversing mirror, and by using an intracavity nonreciprocal device. This paper is devoted to realization of the traveling-wave mode in a mode-locked YAG-Nd ring laser by a method proposed by Tomov et al. This method uses two intracavity Q-switches. In mode-locked operation, pulses are generated that can be considered short compared with the period of modulation T = L/C (where L is the length of the perimeter of the cavity). Analysis shows that if the shift of the switching signals corresponds to the time of travel of a light pulse between Q-switches, the pulse in one direction will pass the Q-switches at instants of zero losses, while losses in the other direction will be maximized for a distance between Q-switches of L/4, and will be zero for a distance L/2. Experimental verification of the proposed method gave unidirectional lasing with an intensity ...
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
A case of {beta}-thalassemia intermedia with spinal cord compression due to extramedullary hematopoiesis, which was successfully treated by blood transfusion, is presented. Emphasis was made on the MRI appearance of extramedullary hematopoiesis on different pulse sequences. The theories that aimed to explain the involvement of the epidural space by extramedullary hematopoiesis are discussed.
twenty 350 V, 2.5 mF aluminum electrolytic capacitors with 10.8 mH inductors made of multi-strand wire. The PFN discharge was controlled using an silicon ...
The major activities of the various Institute's departments are highlighted. The following departments are included: (i) Tokamak; (ii) Pulse plasma systems; (iii) Thermal plasma; (iv) Materials engineering; (v) Laser plasma; and (vi) Optical diagnosis. (P.A.)
The photon rupture method, by which oxide film and metal are removed by focused pulsed Nd-YAG laser beam irradiation, was applied to form artificial micro-pits in Zn-5 mass% Al alloy-coated steel. The zinc alloy-coated layer was removed by pulsed laser irradiation treatment for about one second in a neutral buffer solution with NaCl. The rest potential transient with the laser treatment was measured. In the early stage of the laser treatment the rest potential of zinc alloy-coated steel changed to the negative direction immediately after every irradiation of a laser pulse and then returned to the previous value. However, after the steel substrate was exposed to the solution, the rest potential moved to the positive direction immediately after every irradiation of a laser pulse and then returned to the previous value. The amplitude and duration of the potential change after the laser irradiation ...
The use of dendritic cells (DCs) as a cellular adjuvant is a promising approach to the immunotherapy of cancer. It has previously been demonstrated that DCs pulsed ex vivo with Toxoplasma gondii...Full Text Available
Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available
First structural wall material (FSW) materials in inertial fusion energy (IFE) power reactors will be irradiated under typical repetition rates of 1-10 Hz, for an operation time as long as the total reactor lifetime. The main objective of the present work is to determine whether a continuous-pulsed (CP) approach can be an efficient method in modeling the pulsed activation process for operating conditions of FSW materials. The accuracy and practicability of this method was investigated both analytically and (for reaction/decay chains of two and three nuclides) by computational simulation. It was found that CP modeling is an accurate and practical method for calculating the neutron-activation of FSW materials. Its use is recommended instead of the equivalent steady-state method or the exact pulsed modeling. Moreover, the applicability of this method to components of an IFE power plant subject to repetition rates lower than ...
The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.
The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.
Normal reproductive functioning may require secretion of LH independently of FSH. Variation in GnRH pulse frequency and inhibin negative feedback are mechanisms for differential gonadotropin regulation;...Full Text Available
Atomic oxygen is measured in a pulsed dielectric barrier discharge (DBD) using two-photon absorption laser-induced fluorescence (TALIF). The ground-level atomic oxygen is excited to the 3p "3P state by two-photon absorption at 226 nm. Negative (-40 kV) or positive (+30 kV) pulsed DBD occurs in an O_2-N_2 mixture at atmospheric pressure. The pulse width of the DBD current is approximately 50 ns. The TALIF experiment shows that the decay rate of atomic oxygen increases linearly with O_2 concentration. This result proves that atomic oxygen decays mainly by the third-body reaction, O + O_2 + M #-># O_3 + M. The rate coefficient of the third-body reaction is estimated to be 2.2 x 10"-"3"4 cm"6 s"-"1 in the negative DBD and 0.89 x 10"-"3"4 cm"6 s"-"1 in the positive DBD. It is shown that the decay rate of atomic oxygen increases linearly with humidity. This can explain the well-known fact that ozone production in DBD is ...
A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available
In a mass casualty situation, medical personnel at the disaster site and other field treatment settings may need to monitor the vital signs of hundreds of seriously injured patients with minimal staffing....Full Text Available
The effects of thiol-specific reagents on the amplitude of the electro-olfactogram (E.O.G.) responses elicited from frog olfactory mucosa by pulses of odorant vapours was studied. The impermeant thiol-specific...Full Text Available
Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical ...
The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...
The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. Percutaneous routes that ...
SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...
The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
Significant progress has been achieved recently in the growth of Yttrium Calcium Oxyborate (YCOB) crystals. Boules have been grown capable of producing large aperture nonlinear crystal plates suitable for high average power frequency conversion or optical parametric chirped pulse amplification (OPCPA). With a large aperture (5.5 cm x 8.5 cm) YCOB crystal we have demonstrated a record 227 W of 523.5nm light (22.7 J/pulse, 10 Hz, 14 ns). We have also demonstrated the applicability of YCOB for 1053 nm OPCPA.
This paper reports on the results of experiments into efficient higher-order anti-Stokes Raman conversion of tunable short-pulse XeCl laser radiation. The maximum output energy of the pumping laser, in which the radiation of a frequency-doubled dye laser is amplified by two XeCl laser amplifiers, is 55 mJ with a pulse duration of 1 ns FWHM. Using hydrogen gas as a Raman medium, a series of anti-Stokes lines up to the 12th order (121.5 nm) is generated in the vacuum ultraviolet (VUV) region. 16 references.
Lupus pernio of the nose is the most characteristic cutaneous lesion of sarcoidosis. It is cosmetically disfiguring and can be the cause of significant morbidity. In particular, the affected skin is often red or purple due to increased vasculature. It is particularly resistant to both surgical and medical therapy. We describe a patient with lupus pernio affecting her nose, which showed a dramatic improvement following treatment with the pulse dye laser (PDL). A biopsy taken after treatment showed the continued presence of sarcoidal granulomas. We therefore feel that treatment with the PDL is an effective tool in improving the cosmetic appearance of lupus pernio, but does not influence the underlying disease process. PMID:11360426
Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.
Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed
The paper presents results of experimental research on the interaction of a pulsed plasma-ion stream with a tungsten (W) target. The pulsed hydrogen plasma was produced within the RPI-IBIS (Multi-Rod Plasma Injector) facility at IPJ in Swierk. Measurements were carried out by means of optical spectroscopy and corpuscular diagnostic techniques. For experiments with the W-target the operational conditions (so-called PID mode) were chosen when a clean hydrogen plasma stream was generated. Attention was paid to the identification of WI and WII spectral lines.
Processing techniques utilizing low temperature depositions and pulsed lasers allow the fabrication of polysilicon thin film transistors (TFT`s) on plastic substrates. By limiting the silicon, SiO2, and aluminum deposition temperatures to 100(degrees)C, and by using pulsed laser crystallization and doping of the silicon, we have demonstrated functioning polysilicon TFT`s fabricated on polyester substrates with channel mobilities of up to 7.5 cm2/V-sec and Ion/Ioff current ratios of up to 1x10(to the 6th power).
In situ optical absorption spectroscopy was used to study the generation of E' centres in amorphous SiO_2 occurring by photo-induced breaking of Si-H groups under 4.7eV pulsed laser radiation. The dependence from laser intensity of the defect generation rate is consistent with a two-photon mechanism for Si-H rupture, while the growth and the saturation of the defects are conditioned by their concurrent annealing due to reaction with mobile hydrogen arising from the same precursor. A rate equation is proposed to model the kinetics of the defects and tested on experimental data.
The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).
We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.
The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.
The grain boundary crystallographic misorientations of magnetic-pulse-welded (MPW) aluminum alloy (AA) 6061-T6 in linear and tubular configurations were examined using the electron backscattered diffraction (EBSD) technique. A refined structure of heavily deformed grains with higher grain boundary angles was observed in linear welds. Significant spalling was observed away from the joints, in the interior of tubular welds. The results show the complex interaction of shock waves with the materials during this impact welding process.
The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.
Ascochyta blight causes significant yield loss in pulse crops worldwide. Integrated disease management is essential to take advantage of cultivars with partial resistance to this disease. The most effective practices, established by decades of research, use a combination of disease-free seed, destruction or avoidance of inoculum sources, manipulation of sowing dates, seed and foliar fungicides, and cultivars with improved resistance. An understanding of the pathosystems and the inter-relationship between host, pathogen and the environment is essential to be able to make correct decisions for disease control without compromising the agronomic or economic ideal. For individual pathosystems, some components of the integrated management principles may need to be given greater consideration tha...
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
Two hypotheses are in the centre of this investigation, on the one hand the question, whether microwaves as exogenous fields alone are able to stimulate human muscle cells above-threshold, and on the other hand, whether microwaves as conditioning to cathodical electrical pulses can modify the excitation threshold and form. No excitation through the application of microwaves alone can be introduced at any subject. The conditioning of above-threshold cathodical electrical pulses with UMTS-microwaves leads not to a transgression of the threshold or the electrical muscle response (EMG) depending on the amplitude, the duration or the dose rate. (orig.)
An improved acousto-optic laser Q-switch uses a chirped fm pulse in the acousto-optic cell to diffract and focus the input beam into a resonating high-Q mode. When the rf acoustic pulse is not wholly within the cell, the beam is diverted to the output. A reflective surface is placed on the cell to yield only one output beam and to yield a retroflective beam back into the cavity for a high Q condition whenever a correctly generated chirp acoustic wave is in the proper postion within the cell.
Experiments are described on a plasma cathode with biased grids to prevent entry of ions into the electron extraction gap. The cathode has potential applications to the generation of high-current pulsed electron beams. Operation at 20 A/cm"2 is theoretically possible. The source combines the low average power consumption of a plasma cathode with many of the attractive features of thermionic cathodes, such as space-charge-limited extractor gap electron flow, fast turn-on, and no diode closure. Initial experiments are reported at the 2 A/cm"2 level for pulse lengths to 160 #mu#s.
Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.
In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.
We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.
Conduction-band electrons, formed by pulse radiolysis of Degussa P25 TiO_2 particles, have been monitored by time-resolved microwave conductivity and found to undergo equilibrium localization and eventual recombination at the particle surface. In the presence of isopropyl alcohol recombination is retarded due to surface hole scavenging. The particle bulk can then be pumped with mobile electrons, which survive for seconds.
A new method is described for the analysis of high precision pulse annealing data obtained using IRSL measurements on potassium feldspars using a Risoe reader. Presenting the data as the percentage of the signal lost per annealing phase permits more detailed comparisons to be made between samples. In addition, it is possible to directly compare the temperatures at which the TL and IRSL signals are released, thus giving information about the relationship between them. This method of analysis is applied to pulse annealing data for natural, irradiated, preheated and IR bleached aliquots. (author).
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...
The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to ...
Biosorption of uranium by residual biomass from The Old Bushmill`s Distillery Co. Ltd., Bushmills, Co. Antrim, Northern Ireland, following exposure to short and intense electric pulses has been examined. The biomass was prepared from the distillery spent wash and consisted of non-viable yeast and bacterial cells. As shown previously, untreated biomass had a maximum biosorption capacity of 170 mg uranium/g dry weight biomass. When biosorption reactions were placed between two electrodes and exposed to electric pulses with field strengths ranging from 1.25-3.25 kV/cm at a capacitance of 25 {mu}F, biosorption increased from 170 mg of uranium to 275 mg uranium/g dry weight biomass. The data were obtained from biosorption isotherm analyses and taken as the degree of biosorption at residual uranium concentrations of 3 mM. In addition, when the capacitance of the electric pulses increased from 0.25 {mu}F to 25 {mu}F at a fixed ...
Activation dose rates have been computed for the Poloidal Divertor Experiment Tokamak at the Princeton Plasma Physics Laboratory. Dose rates were computed in one-dimensional (cylindrical) geometry using the ANISN S/sub n/ transport theory code and the DKR radioactivity code. The EPR (DLC37F) 121-group coupled neutron-gamma cross section library was used with ANISN. For DKR, the 46-group neutron library of DCDLIB was employed. Dose rates were calculated for 1 minute, 1 hour, 6 hours, 24 hours, 1 week, and 1 month following a single pulse yielding 10/sup 15/ neutrons and for 2 hypothetical pulsing sequences. First, it was assumed that 10 pulses were conducted each day (1 hour apart) for 5 days. Second, it was assumed that 100 pulses were conducted each day (6 minutes apart) for 5 days. It was found that /sup 56/Mn and /sup 64/Cu are the main contributors to the dose at short time periods after shutdown, ...
The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of ...
Previous in vitro studies have demonstrated that Ho:YLF laser is capable of inducing physical and chemical changes on dental surfaces treated for caries prevention. The temperature in the pulp chamber was in vitro evaluated to as a function of the power and frequency of the laser irradiation. The purpose of this work is to verify the occurrence of pulp inflammation after Ho:YLF laser irradiation using different parameters in rabbits' teeth. The premolars and molars of ten rabbits (NZB) were divided in two groups according to the irradiation energy values of a Ho:YLF laser prototype operating at 2.065{mu}m wave length, frequency of O,5Hz and pulse length of 250{mu}s. An group A teeth were irradiated with using ten pulses of 334mJ/pulse of a Ho:YLF laser prototype operating at O.5Hz, and group B, with 512mJ/pulse. Animals were killed by transcardiac perfusion and the samples were prepared for ...
The paper discusses recent results on the development of localized arc filament plasma actuators and their use in controlling high-speed and high Reynolds number jet flows. Multiple plasma actuators (up to 8) are controlled using a custom-built 8-channel high-voltage pulsed plasma generator. The plasma generator independently controls pulse repetition rate (0-200 kHz), duty cycle and phase for each individual actuator. Current and voltage measurements demonstrated the power consumption of each actuator to be quite low (20 W at 20% duty cycle). Emission spectroscopy temperature measurements in the pulsed arc filament showed rapid temperature increase over the first 10-20 ?s of arc operation, from below 1000 deg. C to up to about 2000 deg. C. At longer discharge pulse durations, 20-100 ?s, the plasma temperature levels off at approximately 2000 deg. C. Modelling calculations using an unsteady, ...
In the two decades since the presentation of the first experimental results, the study of high-power microwaves (HPM) has aimed at the production of microwave pulses with ever higher peak power and ever larger energy content. Drawing on the electrical pulsed power and relativistic electron beam technologies, a mix of sources have produced power levels in excess of 1 GW and pulse energies of tens to a thousand joules in both the centimeter and millimeter wavelength ranges. The potential for military applications of such powerful bursts became a major driving force for substantial research programs -- and considerable advancements -- in the United States and the former Soviet Union. The end of the Cold War and a reexamination of national priorities has diminished the momentum of military HPM development in these countries. Nevertheless, the field hasn`t reached its limits, in capability or applicability, and one sees at ...
An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alpha particle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of ...
We describe a new apparatus that combines pulsed laser excitation in a molecular beam with surface-science methods for preparation of clean single-crystal surfaces and detection of adsorbates to enable state-selected studies of gas-surface reaction dynamics. Reactant molecules are prepared in specific vibrationally excited states via overtone pumping using tunable, narrow-band laser radiation. The collision-free environment of the molecular beam prevents relaxation of the prepared molecules before impact on the target surface and enables complete control over the collision energy and incidence angle. Chemisorption products are detected after a given deposition time by Auger electron spectroscopy. To achieve sufficient beam flux of state-selected reactant molecules for product detection by standard surface-science techniques, we use a high-intensity, short-pulse molecular-beam source matched to the low duty cycle of the ...
The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, subjects breathed a 5% CO(2) ...
This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization method is used to fit a portion of the ECG waveform with a single Gaussian pulse, which is then subtracted from the ECG waveform. The process iterates on the resulting residual waveform until the normalized mean square error is below an acceptable level. Three different minimization methods were compared for their applicability to the ChAD algorithm; the Nelder-Mead simplex method was found to be more noise-tolerant than the Newton-Raphson method or the steepest descent method. Using morphologically different ECG waveforms from the MIT-BIH arrhythmia database, it was demonstrated that the ChAD algorithm is capable ...
Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ?ce > ?pe?b, where ?ce = e?/mec is the electron gyrofrequency, ?pe is the electron plasma frequency, and ...
The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 ..mu..s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2/sup 0/, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-..mu..s pulses. Each tube has ...
The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2_0, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each tube has delivered over ...
The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of the growth of neural stem cells (PHPEMS groups was the same as that in control group (P>0.05). It was suggested that 0.1 Hz, 5 pulses stimulation of HPEMS within ...
The simulation of the temporal evolution of the various neutral gaseous species studied (O, O{sub 3}, H, OH, HO{sub 2}, H{sub 2}O{sub 2}, N, NO, NO{sub 2}, NO{sub 3}, N{sub 2}O, N{sub 2}O{sub 5}, HNO{sub 2}, and HNO{sub 3}) use corona effects. The physical conditions of the discharge were used. The reactions take place in dry or humid air, after the dissociation of O{sub 2}, N{sub 2}, and H{sub 2}O by an electronic pulse. When water vapor is present, there is a probability of production of H{sub 2}O{sub 2}, HNO{sub 2}, and HNO{sub 3} in air. Temperature and humidity have cumulative effects. With multiple pulses, the O{sub 3} maximal concentration is obtained for a limited number of pulses.
The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are + or - 1/2"0, and + or - 1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each tube has ...
This paper reports on the Burning Plasma Experiment (BPX) which when operating at a toroidal field of 8.1 tesla and a plasma current of 10.6 megamps, requires peak power of 1235 megawatts and total pulse energy of over 21 gigajoules. These requirements are twice and over four times the corresponding figures for the Tokamak Fusion Test Reactor (TFTR), respectively. The design of the BPX power system has evolved, along with the tokamak, over a period of several years and has included studies of several alternative approaches. The reapplication of the existing TFTR power and energy facilities has been basic to all approaches. Among the new sources of pulse power and energy that have been considered are: direct utility grid pulsing, new flywheel units, and lead-acid storage batteries. The toroidal field power requirements are the greatest of the BPX subsystems and, fortunately, are sufficiently free of dynamics to allow the ...
The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems and the major modification of replacing the beamline-torus duct ...
Thin films of the protein, lysozyme, have been deposited by the matrix-assisted pulsed laser evaporation (MAPLE) technique. Frozen targets of 0.3-1.0 wt.% lysozyme dissolved in ultrapure water were irradiated by laser light at 355 nm with a fluence of 2 J/cm{sup 2}. The surface quality of the thin lysozyme films of different thickness deposited on 7 mm x 7 mm Si-<1 0 0>-wafers was investigated with scanning electron microscopy and atomic force microscopy. Already at comparatively low thickness, {approx}20 nm, the substrate is covered by intact lysozyme molecules and fragments. The concentration of lysozyme in the ice matrix apparently does not play any significant role for the morphology of the film. The morphology obtained with MAPLE has been compared with results for direct laser irradiation of a pressed lysozyme sample (i.e. pulsed laser deposition (PLD))
In this paper, a relatively high gain (#approx =# 25 to 40 percent) free-electron laser (FEL) with an optical ring resonator is simulated using the code FELEX. The laser system corresponds to the ''burst mode'' FEL scheduled for operation at Boeing Aerospace Company in 1988. The ring consists of paraboloids, grazing incidence by hyperboloids, and a grating rhomb. The wiggler is 5 m in length and has an adjustable taper, while the electron beam is produced by an RF linac. The optical elements of the ring together with the FEL interaction in the wiggler are modeled in three spatial dimensions to investigate the system from start-up to saturation. Both single frequency and finite pulse simulations are performed. The study illustrates the necessity of mode matching the loaded resonator to maximize the extraction efficiency. The mode matching is necessary because the FEL interaction significantly alters the optical beam focus position and Rayleigh range. The ...
CO poisoning is a major issue when reformate is used as a fuel in PEM fuel cells. Normally it is necessary to reduce the CO to very low levels (#approx#5 ppm) and CO tolerant catalysts, such as Pt-Ru, are often employed. As an alternative approach, we have studied the use of pulsed oxidation for the regeneration of CO poisoned cells. Results are presented for the regeneration of Pt and Pt-Ru anodes in a PEM fuel cell fed with CO concentrations as high as 10,000 ppm. The results show periodic removal of CO from the catalyst surface by pulsed oxidation can increase the average cell potential and increase overall efficiency. A method for enhancing the performance of a fuel cell stack using a microprocessor-based Fuel Cell Health Manager (FCHM) has been developed. The results of a cost/benefit analysis for the use of a FCHM on a 4 kW residential fuel cell system are presented. (author)
We demonstrate that fitted values of stellar radius obtained by fitting theoretical light curves to observations of millisecond period X-ray pulsars can significantly depend on the method used to calculate the light curves. The worst-case errors in the fitted radius are evaluated by restricting ourselves to the case of light emitted and received in the equatorial plane of a rapidly-rotating neutron star. First, using an approximate flux which is adapted to the one-dimensional nature of such an emission region, we show how pulse shapes can be constructed using an exact spacetime metric and fully accounting for time-delay effects. We compare this to a method which approximates the exterior spacetime of the star by the Schwarzschild metric, inserts special relativistic effects by hand, and neglects time-delay effects. By comparing these methods, we show that there are significant differences in these methods for some applications, for example ...
Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation from I to II and vice versa. It is suggested that the component I corresponds to ...
We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...
We present measurements of the transmission of radio/microwave pulses through salt in the Cote Blanche salt mine operated by the North American Salt Company in St. Mary Parish, Louisiana. These results are from data taken in the southwestern region of the 1500 ft. (457 m) deep level of the mine on our third and most recent visit to the mine. We transmitted and received a fast, high-power, broadband pulse from within three vertical boreholes that were drilled to depths of 100 ft. (30 m) and 200 ft. below the 1500 ft. level using three different pairs of dipole antennas whose bandwidths span 125 to 900 MHz. By measuring the relative strength of the received pulses between boreholes with separations of 50 m and 169 m, we deduce the attenuation of the signal attributed to the salt medium. We fit the frequency dependence of the attenuation to a power law and find the best fit field attenuation lengths to be 93 \\pm 7 m at 150 ...
Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a daily basis for laser-target experiments. ...
The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.
Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min"-"1), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O_2 mixtures with the maximum efficiency (energy ...
The AP-0 Target Hall Collection Lens is a pulsed device which focuses anti-protons just downstream of the Target. Since the angles at which the anti-protons depart the Target can be quite large, a very high focusing strength is required to maximize anti-proton capture into the downstream Debuncher Ring. The current design of the Collection Lens was designed to operate with a focusing gradient of 1,000 T/m. However, multiple failures of early devices resulted in lowering the normal operating gradient to about 750 T/m. At this gradient, the Lens design fares much better, lasting several million pulses, but ultimately still fails. A Finite Element Analysis (FEA) has been performed on this Collection Lens design to help determine the cause and/or nature of the failures. The Collection Lens magnetic field is created by passing high current through a central conductor cylinder. A uniform current distribution through the cylinder will create a ...
Chlorinated organics are frequently found as harmful soil contaminants and persisted for extended periods of time. A novel approach, named pulsed corona discharge plasma (PCDP), was employed for the degradation of pentachlorophenol (PCP) in soil. Experimental results showed that 87% of PCP could be smoothly removed in 60 min. Increasing pulse voltage, enhancing soil pH, lowering humic acid (HA) in soil and reducing granular size of the soil were found to be favorable for PCP degradation efficiency. Oxidation and physical processes simultaneously contributed to PCP removal in soil and ozone was the main factor in PCDP treatment. C-Cl bonds in PCP were cleaved during PCDP treatment by Fourier transform infrared spectroscopy (FTIR) analysis. The mineralization of PCP was confirmed by total organic carbon (TOC) and dechlorination analyses. The main intermediate products such as tetrachlorocatechol, tetrachlorohydroquinone, acetic acid, formic acid, ...
We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh"-"1 and 35-110 eV/molecule. (author)
One of inherent characteristics of CANDU reactor is positive void reactivity in contrast to other pressurized light water reactors. During the large break loss of coolant accident, power pulse will be occurred during short time of early phase of accident due to positive void reactivity. However the duration of this power pulse is short, energy due to power pulse would be accumulated in the cladding material and will affect the peak cladding temperature or number of failed fuel elements. Recently, Canadian Nuclear Safety Commission (CNSC) indicated that the amount of void reactivity might be larger than the assumed values in safety analysis and this indication was based on the experimental data from ZED-2 facility. Based on that, the estimation of uncertainties due to the void reactivity during LBLOCA is the most important issue for CANDU safety analysis. In this study, a framework of uncertainty evaluation methodology for ...
Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address observed shortcomings and ...
Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible ...
Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of ...
A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...
A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address ...
A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser ...
At Himeji Institute of Technology, the high power microwaves with the peak power of 20 MW, frequency of 12 GHz and pulse duration of 14 ns have been produced with a virtual cathode oscillator (vircator). These high power microwaves offer new applications in various fields. One problem in laser-triggered lightning experiment is the strong attenuation of laser energy by rain, cloud and laser-produced plasma. Microwaves propagate in thundercloud with small loss, and also are able to irradiate much extensive region of targets. In this paper, the fundamental experiment on the air breakdown induced by high power, short pulse microwaves is reported. The experimental setup of the vircator diode for microwave generation is shown. The typical evolution of diode voltage, electron beam current and microwave emission from the top in the course of time is shown. The experimental setup for microwave-induced air breakdown and the experimental procedure are ...
Sodium-dependent high-affinity choline uptake was measured in the striatum, frontal cortex, hippocampus, and hypothalamus of rats after acute exposure (45 min) to pulsed (2 microseconds, 500 pps) or continuous-wave 2,450-MHz microwaves in cylindrical waveguides or miniature anechoic chambers. In all exposure conditions, the average whole-body specific absorption rate was at 0.6 W/kg. Decrease in choline uptake was observed in the frontal cortex after microwave exposure in all of the above irradiation conditions. Regardless of the exposure system used, hippocampal choline uptake was decreased after exposure to pulsed but not continuous-wave microwaves. Striatal choline uptake was decreased after exposure to either pulsed or continuous-wave microwaves in the miniature anechoic chamber. No significant change in hypothalamic choline uptake was observed under any of the exposure conditions studied. We conclude that depending on ...
An electric propulsion concept suitable for delivering heavy payloads from low earth orbit (LEO) to high energy earth orbit is proposed. The system consists of a number of pulsed inductive plasma thrusters powered by a 100 kWe space nuclear power system. The pulsed plasma thruster is a relatively simple electrodeless device. It also exhibits adequate conversion to thrust power in the desired I sub sp regime of 1500 to 3000 seconds for optimal payload transfer from low earth to high earth orbit. Because of these features and the fact that the nuclear power unit will be capable of delivering sustained high power levels throughout the duration of any given mission, the system presented appears to be a very promising propulsion candidate for advanced orbital transfer vehicle (OTV) applications. An OTV, which makes use of this propulsion system and which has been designed to lift a 9000-lb payload into geosynchronous earth orbit, (GEO) is also ...
A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as ...
A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a ...
A prospective, side-by-side comparison study of two different lasers for the treatment of solar- induced telangiectasia was carried out in 14 patients at the Beckman Laser Institute and Medical Clinic. The argon tunable dye laser (Coherent, Palo Alto, Calif.) was used in the method modified from Orenstein and Nelson to completely treat discrete telangiectasias on one cheek. Specifically, the argon tunable dye laser (ATDL) was set at 0.7 - 0.8 watts, 585 nm wavelength, shutter-pulsed at 0.1 second duration with a spot size of 0.1 mm, and individual vessels were 'traced out' with 4X loupe magnification. Each patient's opposite cheek was then treated in the standard fashion with the flashlamp pulsed dye laser (Candela, Natick, Mass.) using a technique similar to Polla's et al. Specifically, the flashlamp pulsed dye laser (FPDL) was set at 585 nm wavelength, pulsed mode of 450 microseconds ...
Wavy interface morphology is observed in Magnetic Pulse Welding (MPW) similarly to that of the Explosion Welding process (EXW). It is recognized that interfacial waves are formed in a periodic manner and have well defined wavelength and amplitude. The phenomenon of wave formation in EXW has been subjected to extensive investigations in which empirical and numerical models have been published. In the present study, a wave formation mechanism for MPW is presented. This wave-creation mechanism was studied by evaluating the influence of sample geometry on wave morphology using stereoscopic optical microscopy. It was found that interfacial waves are formed in a Kelvin-Helmholtz instability mechanism. Reflected shock waves interact with the welding collision point at the weld interface, where in...
MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.
The intensity of erbium up-conversion luminescence could be limited by a saturation effect due to increased pump power. We studied the luminescence saturation of the 550 nm emission on erbium-doped, SiO_2-TiO_2 sol-gel powders under pulsed excitation at 979 and 1532 nm. From the latter, the up-converted luminescence intensity decreased with increasing excitation power, whereas no saturation was observed at 979 nm excitation. We proposed that the saturation effect is determined by the pump power, the erbium content and the lifetime of the corresponding first excited states at different pumping schemes.
A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.
Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).
We present modeling, simulation, and characterization for the dynamic response of clamped-clamped microbeams under mechanical shock. A Galerkin-based reduced-order model is utilized and its results are verified by comparing to finite-element results. The results indicate that the response of a microbeam to mechanical shock is inherently non-linear because of the dominating effect of mid-plane stretching. The effect of the shock pulse shape is investigated. It is concluded that the shape of the shock pulse can result in significant dynamic amplification in the response of the microbeam even in cases where the shock load is considered quasi-static.The combined effect of the electrostatic force and mechanical shock is investigated. The results show that this combined effect can lead to early ...
Summary The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of ...
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
A free-electron laser (FEL) user facility is discussed. The FEL, which will be operated as an oscillator, will be driven by the electron beam of the racetrack microtron (RTM) that is nearing completion. Variation of the electron kinetic energy from 17 MeV to 185 MeV will permit the FEL wavelength to be tuned from 200 nm to 10 #mu#m. Performance will be enhanced by the high brightness, low energy spread, and continuous pulse nature of the RTM electron beam. The authors are designing a new injector to increase the peak current of the RTM. A 3.6-m undulator is under construction, and the 9-m optical cavity is under design. The FEL will emit a continuous train of 3-ps pulses at 66 MHz with an average power of 10--200 W, depending on the wavelength, and a peak power of up to several hundred kW. An experimental area is being prepared with up to five stations for research using the FEL beam.
The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.
We report measurements of the temperature dependence of the threshold current of GaAs, 1.3-..mu..m InGaAsP, and 1.5-..mu..m InGaAsP double heterostructure lasers using short electrical pulses. T/sub 0/approx.200 K is observed for all the lasers. These high T/sub 0/ values show that the carrier density at threshold does not increase rapidly with increasing temperature in any of the lasers studied and thus the observed low cw T/sub 0/ of InGaAsP lasers is primarily due to a decrease of the carrier lifetime at threshold with increasing temperature.
In this work, the pulse plasma nitriding process of pure iron is modelled using a kinetic model derived from the Fick's laws. This approach based on the error function model allows to simulate the growth kinetics of a biphase configuration consisting of {gamma}'-Fe{sub 4}N{sub 1-x} and {epsilon}-Fe{sub 2-3}N iron nitrides under specified conditions. By coupling the kinetics data about the diffusivities of nitrogen in {alpha}-Fe, {gamma}' and {epsilon} phases to the thermodynamic description of the Fe-N phase diagram, it is possible to evaluate the kinetic constant at each growing phase interface, the thickness of nitrided layer, and predict the nitrogen concentration profiles. The comparison between the experimental and theoretical results shows the reliability of the simulation results.
In this work, the pulse plasma nitriding process of pure iron is modelled using a kinetic model derived from the Fick's laws. This approach based on the error function model allows to simulate the growth kinetics of a biphase configuration consisting of #gamma#'-Fe_4N_1_-_x and #epsilon#-Fe_2_-_3N iron nitrides under specified conditions. By coupling the kinetics data about the diffusivities of nitrogen in #alpha#-Fe, #gamma#' and #epsilon# phases to the thermodynamic description of the Fe-N phase diagram, it is possible to evaluate the kinetic constant at each growing phase interface, the thickness of nitrided layer, and predict the nitrogen concentration profiles. The comparison between the experimental and theoretical results shows the reliability of the simulation results.
Radiation from an ultrastable 240 GHz solid state source has been injected, through an isolator, into the cavity of the University of California, Santa Barbara millimeter-wave free-electron laser (FEL). High-power FEL emission, normally distributed among many of the cavity's longitudinal modes, is concentrated into the single mode to which the solid state source has been tuned. The linewidth of the FEL emission is 0.5 MHz, consistent with the Fourier transform limit for the 2 #mu#s pulses. This demonstration of frequency-stable, ultranarrow-band FEL emission is a critical milestone on the road to FEL-based pulsed electron paramagnetic resonance spectroscopy.
The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.
Abstract Residual limb pain (RLP) and phantom limb pain (PLP) can be debilitating and can prevent functional gains following amputation. High correlations have been reported between RLP and the stump neuromas following amputation. Many treatment methods including physical therapy, medications, and interventions, have been used with limited success. Pulsed radiofrequency ablation (PRFA) has shown promise in treating neuropathic pain because of the inhibition of evoked synaptic activity. We present 4 amputees who were treated with PRFA after failing conservative management for their RLP and PLP. All 4 patients underwent PRFA and demonstrated at least 80% relief of RLP for over 6 months. One patient reported a complete resolution of phantom sensation while another patient had significantly de...
Formation of oxidizing and reducing radicals was studied by pulse radiolysis of [Fe(CN)_6]"4"- - BrO_3"- - CN"- system in ethylene glycol - water solvent mixture. Oxidizing #centre dot#BrO_2 and BrO radicals formed by electron scavenging with #centre dot#BrO_2"- were identified and their reactions were investigated. The reaction of hydroxyl radicals with ethylene glycol leads to formation of reactive radicals with reducing properties and of compounds which reduce slowly in dark the ferricyanide formed in the reaction of #centre dot#BrO_2 radical with ferrocyanide. (author) 21 refs.; 7 figs.
The propagation of acoustic pressure perturbations in an adiabatic low-quality air/water flow were investigated both theoretically and experimentally. A linearized dispersion model is correlated with data to extract information on the behavior of interfacial momentum transfer controlled by the virtual volume coefficient. The dispersion model is examined in limiting cases of low and high frequency and related to current models for critical flow velocity. Fourier decomposition techniques are employed to predict the dispersion of measured pressure pulses and to relate data for standing waves and propagating pulses. The dispersion model is based on a two-fluid model and is the most complete model available in the literature at this time. The dispersion data presented herein is also the best available to date for low frequency (i.e., frequencies less than bubble resonance) sound propagation in bubbly air/water mixtures.
Resistive switching memory is a very promising technology for emerging nonvolatile memory applications. Generally, the switching behavior is triggered by a sweep or pulse voltage. In this paper, a charged capacitor is proposed to be used as the external electrical source to program a resistive switching element. From theoretical analyses based on a set behavior model, the capacitor approach can program the device efficiently. Compared with sweep or pulse mode, capacitor driving method can greatly reduce over-programming after the set event, and thus improve the resistance uniformity. The experimental results performed on Cu/ZrO2:Cu/Pt device support this conclusion quite well. The proposed methodology has great value for achieving a reliable resistive switching, which is important for high...
Graphical abstract: - Abstract: Low loading platinum-cobalt (Pt-Co) cathode catalyst on a Nafion(Na+)-bonded carbon layer is fabricated by using galvanostatic pulse technique to show the advantage of electrodeposition for high utilization of catalyst in proton exchange membrane fuel cell (PEMFC). We observed that Pt-Co catalysts evenly exist on the surface of carbon electrode and its thickness is about 5.8 ?m, which is four times thinner than conventional Pt/C. Improved single cell power performance of Pt-Co cathode catalysts with a ratio of 3.2:1 compared with Pt/C is clearly presented.
A three-light, three-lever discrete avoidance behavioral task was initiated to study the effects of a 500-675 rad neutron pulse upon performance. Eight primates performed the task for 4 h(3.5 h postexposure) on exposure day and for 4 h on each of 3 d postexposure. For the exposure day, five subjects had a decrease in correct responses, seven had increased reaction times, and six experienced productive emesis within 3.5 hours postexposure. Although the performance degradations were not severe, these data suggest that the performance of time critical tasks could be significantly impaired.
In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.
We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.
The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O_2 + M #-># O_3 + M, is estimated to be 2.5 x 10"-"3"4 cm"6 s"-"1.
One-electron oxidation of several derivatives of pyrazolin-5-one, including the drug antipyrine, were studied by pulse radiolysis of aqueous solutions. All the compounds were found to be oxidized by Br2 rapidly but considerably more slowly by weaker oxidants, such as peroxyl radicals. From redox equilibria using p-methoxyphenol and N,N,N',N'-tetramethyl-p-phenylenediamine as reference compounds, the one-electron oxidation potentials of the methyl-substituted 2-pyrazolin-5-ones were found to be in the range of 0.32-0.39 V versus normal hydrogen electrode. The relevance of these findings to the properties of the drug nafazatrom is discussed. Antipyrine was found to have a much higher oxidation potential, estimated as 1.2-1.5 V, which is rationalized on the basis of the phenyl substitution and lack of resonance stabilization of the radical cation.
Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed during this process.
In this paper we study theoretically a pulsed corona discharge plasma in air at atmospheric pressure. A self consistent one-dimensional model, using a flux-corrected transport numerical scheme, is presented to achieve it. The charged particle kinetics in this model are described by one-dimensional continuity equations coupled with Poisson's equations. The spatio-temporal local field, charge density variations and the velocity profile of an ionizing front are calculated to describe the dynamical behavior of corona discharge plasmas. The simulation results of a wire-in-cylinder corona discharge plasma explain the physical mechanisms of discharge processes. These results may also be apply to obtain the optimizing parameters for designing the plasma reactor.
A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.
The effects of spin diffusion on the free induction decay (FID) of protons associated with the noncrystalline domains of two polymers, polyethylene and blended Nylon 66 (ZYTEL-408), have been examined using Goldman--Shen NMR pulse sequence ((1/2)..pi..x-t/sub 0/-(1/2)..pi..x-bar-tau-(1/2)..pi..x-t). At tau< or approx. =100 ..mu..s, the FID is drastically distorted from the exponential form while at longer tau(tau> or approx. =500 ..mu..s) an exponential FID is observed; but its transverse spin relaxation rate is smaller than that of the FID obtained after a single (1/2)..pi..x pulse and approaches this value at the limit of large tau. These findings are interpreted in terms of the theory of rapid spin diffusion. The spatial variation in the spin relaxation rate within the noncrystalline domain is inferred.
An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.
Magnetic pulse welding, a cold solid state bonding process, is becoming a viable replacement for conventional fusion welding processes and explosive welding. The process is presented here along with its fundamental equations and applications of similar and dissimilar welds are illustrated along with typical interface microstructures. (orig.) [German] Magnetimpuls-schweissen, ein Verbindungsverfahren im kalten Festzustand, wird ein funktionsfaehiger Ersatz fuer das herkoemmliche Schmelzschweissverfahren und das Explosionsschweissverfahren. Das Verfahren wird hier mit seinen grundlegenden Gleichungen vorgestellt, und Anwendungen von aehnlichen und unaehnlichen Schweissungen werden mit typischen Schnittstellen-Mikrostrukturen veranschaulicht. (orig.)
A 340-watt CO_2 laser is being used to generate PuO_2-UO_2 condensation aerosol from the surface of a Liquid Metal Fast Breeder Reactor (LMFBR) fuel pellet. A wide range of concentrations is achieved by varying the laser power, pulse width, and/or pulse period. The resulting aerosol is composed of branch chain-like aggregates, with the primary particle size ranging between 0.005 and 0.15 #mu#m. X-ray diffraction analyses show that these aerosols condense into a face-centered cubic crystal structure. The activity mean aerodynamic diameter (AMAD), for most power levels, is approximately 0.85 #mu#m with a geometric standard deviation of 1.5.
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
DZ4 substrates were coated with NiCoCrAlY by plasma spray and subsequently treated by high current pulsed electron beams(HCPEB) of different parameters. The surface microstructure, phase structure and high temperature oxidation resistance were studied. It has been shown that as a result of the HCPEB treatment the loose and rough structure remelted and the surface became smooth. Smooth microregion, craters and cracks appeared on the surface. The ?' phase manifolded and there was no visible thermal stress. The oxidation test at 900 degree C for 100 h showed that a more compact and successive ?-Al_2O_3 scale was formed on the surface of the samples after HCPEB irradiation, which improved the oxidation resistance of the NiCoCrAlY coatings obviously. (authors)
A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation measurement shows that gas-barrier property enhances due to the ...
A new test methodology is described which allows access to loading rates that lie between split Hopkinson bar and shock-loading techniques. Gas gun experiments combined with velocity interferometry techniques have been used to experimentally determine the intermediate strain-rate loading behavior of Coors AD995 alumina and Cercom silicon-carbide rods. Graded-density materials have been used as impactors; thereby eliminating the tension states generated by the radial stress components during the loading phase. Results of these experiments demonstrate that the time-dependent stress pulse generated during impact allows an efficient transition from the initial uniaxial strain loading to a uniaxial stress state as the stress pulse propagates through the rod. This allows access to intermediate loading rates over 5 x 10{sup 3}/s to a few times 10{sup 4}/s.
Magnetic pulse welding is a solid state impact welding process, similar to explosive welding, which produces metallurgical bond by oblique high-speed impact between two metal bodies. This violent impact removes the metal surface oxide layers and then joins the two atomic level clean metal surfaces together by the incidental compression pressure. The impact velocity is at 200?400?m/s and the being welded metal surface undergoes severe plastic deformation with strain rate in the order of 106?107?s?1. The ultrafine-grained structure was observed on the welded interface. This article studied two types of similar material lap joint interfaces and the base metals were aluminum alloy 6061 and copper alloy 110. Nano-indentation testing shows that the welded interfaces have significantly greater ha...
This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse annealing results and the loss of TL due to IR exposure of the ...
Abstract Background and Purpose: During laser lithotripsy, working instruments are often in close proximity to the distal fiber tip and may be damaged accidentally or even intentionally. The aim of this study was to compare the amount of damage to a standard guidewire and the nitinol wires of endourologic retrieval baskets that were affected by three different clinically available laser systems. Materials and Methods: The impact of pulsed laser irradiation on a standard hydrophilic guidewire and a retrieval basket were investigated. One infrared (IR) laser system (holmium:yttrium-aluminum-garnet [Ho:YAG]: ????=???2100???nm) and two laser systems emitting light in the visible (VIS) spectral range (frequency-doubled double-pulse neodymium:YAG [FREDDY]: ????=???532???nm/1064???nm and flashl...
The following is the optimized pulsed laser deposition (PLD) procedure by which we prepared the final samples that were sent to LLNL. These samples are epitaxial multilayer structures of Si/YSZ/CeO/NSMO, where the abbreviations are explained in the following table. In this heterostructure, YSZ serves as a buffer layer to prevent deleterious chemical reactions, and also serves to de-oxygenate the amorphous SiO{sub 2} layer to generate a crystalline template for epitaxy. CeO and BTO serve as template layers to minimize the effects of thermal and lattice mismatch strains, respectively. More details on the buffer and template layer scheme are included in the manuscript [Yong et al., 2008] attached to this report.
It is shown that a gun similar to that in the SSPX could demonstrate the high fields required for Pulsed Spheromak reactors merely by prolonging the pulse. Important considerations are choosing the voltage to exceed ohmic losses; designing the gun to avoid wasteful short-circuiting of current within the gun; and the injection efficiency factor, f, determined by the ''sag'' in the profile of {lambda} = {mu}{sub o}j/B. Typically f = 0.75 in experiments, giving an overall efficiency > 50 % if short-circuiting is avoided. Theoretical transport models agree qualitatively with the need for a finite gradient in h to pump in helicity by current-driven tearing modes and suggest that pressure-driven resistive modes would not compete with current-driven modes during a buildup to ohmic ignition.
The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.
This paper investigates the effects of the electric current pulse (ECP) on the interface stability of Al-4.5% Cu alloy during the directional solidification. Experimental results show both the cellular spacing and the mushy zone depth decrease with increasing current density, moreover, the solid-liquid interface morphology transforms from dendritic to cellular or even planar interface. The secondary dendrites are suppressed due to the homogeneous distribution of the solute and the increase of temperature gradient originated from ECP. The decrease of the cellular spacing results from branching of the cellular tip caused by Joule heat of the current exerting on cellular tip.
We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...
We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)
The possibilities to grow isolated structures of complex oxides by pulsed laser deposition through stencils were investigated. A stencil consisting of a SiN membrane with apertures of several hundred nanometers embedded in a Si chip is placed in front of a heated substrate (up to 750 degrees Celsius). Deposition through these apertures results in resistless, direct patterning by local deposition of complex oxides like ferroelectric Lead Zirconate Titanate. The created isolated structures were analyzed by AFM imaging. Under-deposition, in this work called broadening, is inevitable during stencil deposition and is depending on deposition parameters, especially pressure. Different causes of broadening are mapped and discussed.
A new methane cold neutron source has been tested at the IBR-2 pulsed reactor at the Frank Laboratory of Neutron Physics. In a paper the results of experiments at neutron diffractometers HRFD and DN-2 which are placed at the IBR-2 from the methane moderator side are given. A comparison with the results obtained with the conventional water comb-like moderator is performed. The perspectives of the cold source for various kinds of neutron diffraction experiments, including atomic and magnetic structural analysis and real time experiments are discussed. It is shown, that for a huge number of the experiments which are performing at both HRFD and DN-2 the methane cold neutron source provides the better conditions than water comb-like moderator.
Plasma Technologies in Institute of Plasma Physics of the NSC KIPT are recently developed in the following directions. Material surfaces modification under their irradiation with pulsed plasma streams of different working gases. Besides traditional analysis of improvements of tribological characteristics and structural-phase changes of the modified layers recently we started investigations of material corrosions characteristic improvement under influence of pulsed plasma on the material surfaces. As to the surface coatings in arc discharges of Bulat type devices, new trends are related with multi-layers coatings, using Ti-AI-N coatings in cutting tools, using high frequency discharges or combined HF- and arc discharges for increasing the nomenclature of goods to be coated. Development of ozonators is respectively new area for IPP NSC KIPT. On the base of barrier high-frequency discharge there were developed a number of high efficiency ozonators ...
A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
The study examines advances in Chinese High Power Microwaves (HPM) research and its associated technologies: pulsed power, high-power microwave sources, and high-power microwave components. It draws from open literature published in Chinese and English, communication with US scholars who have visited China recently, and communication with Chinese researchers in the United States. The study is limited to frequencies ranging from 1 GHz to 300 GHz. It includes both high peak power microwaves and high average power microwaves. The technical review section of this study is ordered in technological sequence, starting with the pulsed-power systems required to form the intense relativistic electron beams, then assessing microwave source research and development, and finally discussing high-power microwave components.
The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...
We propose a method of plasma production by capacity-coupled multidischarge (CCMD) at atmospheric pressure. The discharge gaps in the CCMD consist of a common electrode and a number of compact electrodes (CCE) which are directly coupled with small capacitors for quenching the discharge. A simple CCE structure is provided by a cylindrical capacitor, the inner conductor of which is used as a gap electrode. A short pulse discharge is observed to appear homogeneously at each CCE. A charge transfer for the single-pulsed discharge is 10-100 times as large as that of the conventional dielectric barrier discharge. A high efficiency of ozone production has been confirmed in the CCMD using O_2 gas. A device configuration of the CCMD is quite flexible with respect to its geometrical shape and size. The CCMD could be used to produce plasmas for various kinds of industrial applications at atmospheric pressure.
We have generated approximately 100 watts of frequency doubled light from the output of an electro-optically Q-switched, diode-pumped Nd:YAG slab laser oscillator operating at an average power of 200 watts (2.5 kHz repetition rate, 80 mJ/pulse, 25 ns pulsewidth). The Q-switch was a compensated z-axis propagation LiNbO{sub 3} electro-optic modulator, and the frequency conversion crystal was a thin slab of KTP. In addition, Q-switched operation at an average power of approximately 250 watts with 26 ns pulsewidths has been demonstrated.
Plasma arc welding processes are used in off-shore industry for construction and maintenance in the wet surrounding of underwater structures and pipelines. In greater water depth the density of the plasma gas increase because of the greater hydrostatic pressure. This causes the increase of conductive heat losses to the wet surrounding. To keep up the energy flux to the workpiece to be welded, the plasma arc has to burn in a local dry area with an inside pressure of 1 bar. This requirement can be fulfilled by a rotating cylinder with a liquid film flowing down the inner wall. The flow around the rotating cylinder to create a local dry area around the plasma arc under water is experimentally investigated. The rotating cylinder is placed above the work surface which is simulated by a flat plate. According to the centrifugal forces of the rotating flow inside the gap between the lower end of the cylinder and the flat plate the water is forced out of the cylinder. The velocity distribution ...
The aim of this study was to document vascular complications that occurred following cadaveric and living donor kidney transplants in order to assess the overall incidence of these complications at our center as well as to identify possible risk factors. In a retrospective cohort study, 1500 consecutive renal transplant recipients who received a living or cadaveric donor kidney between December 1988 and July 2006 were evaluated. The study was performed at the Nemazee Hospital, Shiraz, Iran. The assessment of the anatomy and number of renal arteries as well as the incidence of vascular complications was made by color doppler ultrasonography, angiography, and/or surgical exploration. Clinically apparent vascular complications were seen in 8.86% of all study patients (n = 133) with the most frequent being hemorrhage (n = 91; 6.1%) followed by allograft renal artery stenosis (n = 26; 1.7%), renal artery thrombosis (n = 9; 0.6%), and renal vein thrombosis (n = 7; 0.5%). ...
To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The coronal helicity of the AR is estimated to be -4.3 x 10"4"3 ...
This thesis presents the study of the slowing down process of fast heavy ions inside matter. In the framework of this research, the influence of the target density on the stopping process is investigated. Experiments on the interaction of {sup 48}Ca{sup 6+}-{sup 48}Ca{sup 10+} and {sup 26}Mg{sup 5+} ion beams with initial energies of 11.4 MeV/u and 5.9 MeV/u with solid and gaseous targets have been carried out. A novel diagnostic method, X-ray spectroscopy of K-shell projectile radiation, is used to determine the ion charge state in relation to its velocity during the penetration of fast heavy ions inside the stopping material. A spatially resolved analysis of the projectile and target radiation in solids is achieved for the first time. The application of low-density silica aerogels as stopping media provided a stretching of the ion stopping length by 20 - 100 times in comparison with solid quartz. The Doppler Effect observed on the projectile K-shell spectra is ...
''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift (#omega##approx#k_#theta#E_r/B_#phi#) and a ...
For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons from the atoms contained in the crystal. Therefore, total power in the FEL laser is ...
The impingement of a fluid jet onto a surface has broad applications across many industries. Within the UK nuclear industry, during the final stages of fuel reprocessing, impinging fluid jets are utilised to mobilise settled sludge material within storage tanks and ponds in preparation for transfer and ultimate immobilisation through vitrification. Despite the extensive applications of impinging jets within the nuclear and other industries, the study of two-phase, solid loaded, impinging jets is limited, and generally restricted to computational modelling. Surprisingly, very little fundamental understanding of the turbulence structure within such fluid flows through experimental investigation is found within the literature. The physical modelling of impinging jet systems could successfully serve to aid computer model validation, determine operating requirements, evaluate plant throughput requirements, optimise process operations and support design. Within this project a method is ...
Full text: A 51-year-old woman with end stage renal failure secondary to Haemolytic Uraemic syndrome underwent a cadaveric renal transplant. A routine post transplant DTPA scan was performed which demonstrated satisfactory renal transplant perfusion and function. Incidental note was made of tracer uptake in the pelvis in the mid-line, which was suspected to be a uterine fibroid. This was confirmed on ultrasonography and at surgery. One week post transplantation the patient became acutely unwell and at laparotomy a perforated diverticular abscess was drained. Intraoperatively the transplant kidney was examined and the surgeon thought there was a area of infarction. This was confirmed on biopsy. As the patient's creatinine was rising a repeat DTPA study was performed. Perfusion and function of the transplant kidney was virtually absent while Doppler studies showed no flow. The patient however continued to produce urine and the creatinine was stable. Subsequently a ...
A ZephIR prototype wind lidar manufactured by QinetiQ was mounted on the nacelle of a Vestas V27 wind turbine and measurements of the incoming wind flow towards the rotor of the wind turbine were acquired for approximately 3 months (April - June 2009). The objective of this experiment was the investigation of the turbulence attenuation induced in the lidar measurements. In this report are presented results from data analysis over a 21-hour period (2009-05-05 12:00 - 2009-05-06 09:00). During this period the wind turbine was not operating and the line-of-sight of the lidar was aligned with the wind direction. The analysis included a correlation study between the ZephIR lidar and a METEK sonic anemometer. The correlation analysis was performed using both 10 minutes and 10 Hz wind speed values. The spectral transfer function which describes the turbulence attenuation, which is induced in the lidar measurements, was estimated by means of spectral analysis. An attempt to increase the ...
The purpose of this thesis is to study the behaviour of the simultaneous flow of oil and water in horizontal pipes. In this connection, two test facilities are used. Both facilities have horizontal test sections with inner pipe diameters equal to 2 inches. The largest facility, called the model oil facility, has reservoirs of 1 m{sub 3} of each medium enabling flow rates as high as 30 m{sub 3}/h, which corresponds to mixture velocities as high as 3.35 m/s. The flow rates of oil and water can be varied individually producing different flow patterns according to variations in mixture velocity and input water cut. Two main classes of flows are seen, stratified and dispersed. In this facility, the main focus has been on stratified flows. Pressure drops and local phase fractions are measured for a large number of flow conditions. Among the instruments used are differential pressure transmitters and a traversing gamma densitometer, respectively. The flow patterns that appear are classified ...
The state of lithium electrode surface after contact with triethylamine-modified propylene carbonate solutions of lithium perchlorate was studied using the pulse galvanostatic technique as well as methods of SIMS and electron microscopy. It was shown that amine added into the solutions stabilizes the state of lithium and prevents the formation of a secondary porous passive film on the lithium surface. Chemical composition of the primary film remains unchanged. Certain properties of passive films formed in electrolyte solutions studied were evaluated.
A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown.
A review of theoretical and observational research on the magnetopause during 1987-1990. Starting with recent work on magnetic reconnection, the review proceeds to magnetopause surface wave phenomena, including the controversy over the role of solar wind pressure pulses in the coupling process and in the mimicking of flux transfer events signatures, and finishes with the magnetopause structure and associated wave phenomena. Recent advances in computer modeling of the magnetopause and the pertinent processes are also discussed. 108 refs.
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
The high pressure discharges (pulsed or D C corona, barrier, gliding and the others), have been studied both experimentally and theoretically as sources of low temperature plasma for pollution control technologies. The potential of electrical discharge methods has been demonstrated for the decomposition of many types of VOC. The air or oxygen are used as a feed gas in which pollutant is diluted. The ozone production in air or oxygen in such discharges is also discussed
A new multipellet long-pulse plasma fueling system is in operation on JET. In the initial experimental phase, a variety of plasma density profile shapes have been produced with peak to average values ranging up to 2.5 and peak plasma density up to 1.2 )times) 10/sup 20/m/sup )minus/3). 7 refs., 4 figs
The salient features of the near-infrared free-electron laser (FEL) that is under construction at the new Darmstadt superconducting 130-MeV electron accelerator are discussed. Special attention is given to the layout and the parameters of the accelerator, the layout of the planned FEL experiment, the characteristics of the electron gun, the subharmonic chopper-buncher system, and the hybrid undulator system of the Darmstadt FEL. A comparison of the planned Darmstadt FEL with conventional lasers, with respect to the pulse and wavelength region, is presented. 15 refs.
It is shown that the interpretation of the experimental results reported in the publication "Storage of Light in Atomic Vapor" by D.F.Phillips et al., Phys. Rev.Lett. 86, 783 (2001) [quant-ph/0012138] is incorrect. The experimental observation of this paper can be consistently explained in the framework of standard concepts of the physics of optical pumping and has nothing to do with "storage of light", or "dynamic reduction of the group velocity", or "light pulse compression".
Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.
A CO/sub 2/ laser chain able to supply approx.=30 MW on a single mode TEM/sub 00/ is described. The coupling of a modified Lumonics 101 module with a low-pressure cell constitues the oscillator and two further Lumonics 103 stages two amplifiers. The final pulse achieves the energy of 4.0 J with 90% of this energy in a peak of 100 ns FWHM.
An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
... Electro-Osmotic Pulse (EOP) technology forces moisture to flow through concrete surfaces against the hydraulic gradient when an electric field is applied to an embedded anode system. This flow is initiated by the movement of cations (positively charged ions) present in a porous medium such as concrete toward the negative earth. Water surrounding the cations moves with them. The Corps of Engineers owns and maintains many buried ...
Goal was developing optical methods for study of dynamic processes at the electrode/electrolyte interface. In the past year, optical second harmonic generation was used for time-resolved measurements of thallium deposition on Cu(111). The studies of carrier dynamics in photo-excited materials have involved both steady-state and picosecond time-resolved luminescence measurements following photoexcitation of the semiconductor material.
The susceptibility of solid "3He is deduced from multiple echoes observed in pulsed NMR experiments. It follows a Curie Weiss law at high temperature, increases faster than this law below 5 mK and drops abruptly around 1 mK. (Auth.).
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)
Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and ...
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
The history of the Czech Institute of Plasma Physics is highlighted. The article is structured as follows: Cyclic accelerators; Interaction of an external high-frequency field and high-temperature plasma - the tokamak; Interaction of an external high-frequency field and high-temperature plasma - pulse plasma systems; Low-temperature plasma - plasma technologies and new materials; Laser plasma - PALS; Optical diagnosis; and Teaching, conferences and international cooperation. (P.A.)
The properties of Mn-doped GaAs layers grown by laser deposition were investigated with measurements of Hall effect and magneto-optical Kerr effect (MOKE). The electrical and magnetic parameters of the layers were defined by growth temperature and quantity of sputtered Mn. It was shown that room-temperature ferromagnetism is revealed by MOKE and, after ruby laser 25 ns pulse annealing, by Hall effect measurements.
A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for ...
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
A microwave hydrogen ion source was developed to improve reliability, and to increase operation time of proton linac application systems. The ion source needs no filament in the discharge chamber, which leads to better reliability and less maintenance time. The developed source produced a maximum hydrogen ion beam current of 70 mA (high current density of 360 mA/cm2, beam energy of 30 keV) with a 5 mm diam extraction aperture and 1.2 kW microwave power. The proton fraction was increased with an increase in rf power and reached around 90% at 1 kW. Measured 90% beam normalized emittance was 0.4 #pi# mm mrad. Rise times of rf power and beam current to 90% of the final values were about 30 and 35 #mu#s, respectively, at a pulse operation mode with 400 #mu#s pulse width and 100 Hz repetition rate. The dynamic range of beam currents was enlarged (3-63 mA) in the pulse mode with a modified rf wave form to assist ignition of ...
The results of the creep performance studies at temperatures from 700-1000 C with welds of alloy 800 HT, the manual shielded metal arc welds made with Githerm 85 and Grini 209 filler metals, as well as the MIG pulsed arc welds made with the Nicrofer S 206 and Nicrofer S 5520 filler metals, proved to be in very good agreement with the calculated characteristic values published on VdTUeV sheet 434 in comparative assessments based on creep values valid for a service period of 10 000 hours. The MIG pulsed arc weld made with the Nicrofer S 5520 filler metal achieved by far the best results and strength values comparable to those of the base material, whereas the values of the other welds were corresponding to calculated strength values of the base material reduced by 20%. (orig./CB) [Deutsch] Die im Temperaturbereich von 700-1000 C an Alloy 800 HT und den Elektrodenhandschweissverbindungen mit den Schweisszusaetzen Gritherm 85 und Grini 209, sowie ...
The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting structures from fusion neutrons thereby ...
Salmonella enterica subsp. enterica serovar Typhimurium was isolated from diarrheic piglets in 2 periods, 2000–2001 (n = 25) and 2005–2006...Full Text Available
Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).
The authors present design methodology and initial experimental results for a high power microwave switch. The switch is designed for application to the pulse compression system associated with the Next Linear Collider Test Accelerator (NLCTA). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. They explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission.
A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.