WorldWideScience
 
 
1

A Method for Accurate in silico modeling of Ultrasound Transducer Arrays  

UK PubMed Central (United Kingdom)

This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available

2009-05-01

3

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good ...

2007-03-01

4

Interobserver agreement in ultrasonography of the finger and toe joints in rheumatoid arthritis.  

DEFF Research Database (Denmark)

OBJECTIVE: To evaluate the interobserver agreement of ultrasonographic assessment of finger and toe joints in patients with rheumatoid arthritis (RA) by 2 investigators with different medical backgrounds. METHODS: Ultrasonography and clinical examination were performed on 150 small joints of 30 patients with active RA. A General Electric LOGIQ 500 ultrasound unit with a 7-13-MHz linear array transducer was used. In each patient, 5 preselected small joints (second and third metacarpophalangeal, second proximal interphalangeal, first and second metatarsophalangeal) were examined independently on the same day by 2 ultrasound investigators (an experienced musculoskeletal radiologist and a rheumatologist with limited ultrasound training). Joint effusion, synovial thickening, bone erosions, and power Doppler signal were evaluated in accordance with an introduced 4-grade semiquantitative scoring system, on ...

2003-01-01

5

MR imaging of experimental intramuscular hemorrhage at 0. 02 T; Contrast enhancement with Gd-DOTA  

Energy Technology Data Exchange (ETDEWEB)

Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).

1990-09-01

6

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 ...

2008-11-21

7

TEMPERATURE TRANSDUCERS: WHAT'S COOKING?  

Science.gov (United States)

... Accession Number : ADD874310. Title : TEMPERATURE TRANSDUCERS: WHAT'S COOKING? Corporate Author : Personal ...

1979-05-01

8

Vector Velocity Imaging Using Cross-Correlation and Virtual Sources  

DEFF Research Database (Denmark)

Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, measurements have ...

2006-01-01

9

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP ...

2008-05-07

13

Ultrasound and airflow induced thermal instability suppression of DC corona discharge: an experimental study  

International Nuclear Information System (INIS)

The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the ...

2006-02-01

14

Acoustic transducer for acoustic microscopy  

Energy Technology Data Exchange (ETDEWEB)

A shear acoustic transducer-lens system in which a shear polarized piezoelectric material excites shear polarized waves at one end of a buffer rod having a lens at the other end which excites longitudinal waves in a coupling medium by mode conversion at selected locations on the lens.

1990-01-01

16

BUDGET ESTIMATES - NASA Headquarters  

Science.gov (United States)

extravehicular activity; an exploding bridgewire firing unit for rocket engines ; a pressure transducer that can withstand the 6000 OF temperiiture ...

17

Ultrasonic piezoelectric transducer that forms a specified directivity pattern  

Energy Technology Data Exchange (ETDEWEB)

Methods of designing ultrasonic piezoelectric transducers in accord with a specified directivity pattern are analyzed and general formulas are presented for the design problem. As an example, the pressure distribution on the working surface of a circular piezoelectric transducer is determined that is capable of forming a narrow weakly divergent beam. Experimental results are presented with respected to ultrasonic fields that support the theoretical conclusions.

1989-03-01

18

Ultrasound diagnosis of cephalopagus conjoined twin pregnancy at 29 weeks  

UK PubMed Central (United Kingdom)

The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available

19

Targeted gene transfection from microbubbles into vascular smooth muscle cells using focused, ultrasound-mediated delivery  

UK PubMed Central (United Kingdom)

We investigate a method for gene delivery to vascular smooth muscle cells using ultrasound triggered delivery of plasmid DNA from electrostatically coupled cationic microbubbles. Microbubbles...Full Text Available

2010-09-01

20

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

 
 
 
 
21

Mid-trimester diagnosis of bladder neck obstruction by ultrasound and paracentesis.  

UK PubMed Central (United Kingdom)

A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available

1983-06-01

22

Correspondence of Ultrasound Elasticity Imaging to Direct Mechanical Measurement in Aging DVT in Rats  

UK PubMed Central (United Kingdom)

Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available

2005-10-01

23

A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis  

UK PubMed Central (United Kingdom)

Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available

2010-04-01

25

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip ...

2009-09-14

26

Replication-defective vectors of reticuloendotheliosis virus transduce exogenous genes into somatic stem cells of the unincubated chicken embryo  

Energy Technology Data Exchange (ETDEWEB)

Replication-defective vectors derived from reticuloendotheliosis virus were used to transduce exogenous genes into early somatic stem cells of the chicken embryo. One of these vectors transduced and expressed the chicken growth hormone coding sequence. The helper cell line, C3, was used to generate stocks of vector containing about 10/sup 4/ transducing units per ml. Injection of 5- to 20-..mu..l volumes of vector directly beneath the blastoderm of unincubated chicken embryos led to infection of somatic stem cells. Infected embryos and adults contained unrearranged integrated proviral DNAs. Embryos expressed the transduced chicken growth hormone gene and contained high levels of serum growth hormone. Blood, brain, muscle, testis, and semen contained from individuals injected as embryos contained vector DNA. Replication-defective vectors of the reticuloendotheliosis virus transduced ...

1989-06-01

27

Optoelectronic multipoint liquid level sensor for light petrochemical products  

Science.gov (United States)

In this article we describe an optoelectronic sensor for assessing the level of light petrochemical products in technological tanks at the oil refineries. This sensor employs the multi-element vertical array of discrete micro- optical refractometric transducers. The transducers are made of silica glass and have the conical shape. In the air, each transducer operates as a tiny retro-reflector that optically couple together two multimode optical fibers. The optical coupling in the transducer is due to the internal reflection at the conical surface. The amount of the coupling depends on the refractive index of the surrounding media. In a fluid, the total internal reflection vanishes and the coupling becomes negligibly small. The number of immersed transducers is a measure of the fluid level in the reservoir. Because of the significance of the transducer ...

2000-06-01

28

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

29

The Natural Statistics of Audiovisual Speech  

UK PubMed Central (United Kingdom)

Humans, like other animals, are exposed to a continuous stream of signals, which are dynamic, multimodal, extended, and time varying in nature. This complex input space must be transduced and sampled...Full Text Available

2009-07-01

30

SPACE STATION INTEGRATED WALL DESIGN AND PENETRATION  

Science.gov (United States)

screens of fine wire was placed between the gun barrel and the panel to determine whether the gun performance was repeatable. The transducers were placed ...

31

Machine condition monitoring - the way ahead  

Energy Technology Data Exchange (ETDEWEB)

During the last fifteen years a variety of instruments and transducers, such as voltage plugs, power transducers, flow and pressure transducers, recorders and tensometers, have been developed for underground use in measuring the performance and technical parameters of prototype machines. The equipment, until recently, has been in a portable form and was found useful by the industry generally, in fault finding and trouble-shooting exercises and in commissioning procedures performed by small teams on a call-out basis. Over the last five years the test equipment has been adapted and the techniques modified to suit individual colliery-based operations with more permanent machine mounted and built-in transducers. At the moment these techniques operate within the framework of a statutory planned preventive maintenance scheme for each mine. This paper discusses the merits of changing from preventive ...

1984-11-01

32

Transurethral Ultrasound Diffraction Tomography  

Science.gov (United States)

... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...

2007-03-01

33

NASA - Get (In) on NASA Innovation!  

Science.gov (United States)

Sep 19, 2011 ... (The whispering voice, on the other hand, was the latest in ultrasound directed audio technology from the firm Audio Spotlight.) The NASA ...

34

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

35

Breast Cancer Treatment  

Medline Plus

... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...

36

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

37

Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea  

UK PubMed Central (United Kingdom)

Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available

2009-06-01

38

Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available

39

Two-phase flow regime observations in a vertical hexagonal flow channel with and without a finned fuel bundle  

International Nuclear Information System (INIS)

Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, Real-Time Neutron Radiography, pressure transducer and ...

1990-12-10

40

The Induction of APC with a Distinct Tolerogenic Phenotype via Contact-Dependent STAT3 Activation  

UK PubMed Central (United Kingdom)

BackgroundActivation of the signal transducer and activator of transcription 3 (STAT3) within antigen presenting cells (APCs) is linked to abnormal APCs differentiation and function....Full Text Available

 
 
 
 
41

Instructional control of an autonomic sexual response1  

UK PubMed Central (United Kingdom)

Four of seven human male subjects developed full penile erections when exposed to erotically stimulating motion pictures. Changes in penile size were detected by a mercury strain gauge transducer and...Full Text Available

1969-01-01

42

Identifying related L1 retrotransposons by analyzing 3' transduced sequences  

UK PubMed Central (United Kingdom)

BackgroundA large fraction of the human genome is attributable to L1 retrotransposon sequences. Not only do L1s themselves make up a significant portion of the genome, but L1-encoded...Full Text Available

2003-01-01

43

Highly efficient concentration of lenti- and retroviral vector preparations by membrane adsorbers and ultrafiltration  

UK PubMed Central (United Kingdom)

BackgroundLentiviral vectors (LVs) can efficiently transduce a broad spectrum of cells and tissues, including dividing and non-dividing cells. So far the most widely used method...Full Text Available

44

Differential interleukin-6/Stat3 signaling as a function of cellular context mediates Ras-induced transformation  

UK PubMed Central (United Kingdom)

IntroductionTyrosine phosphorylated signal transducer and activator of transcription 3 (pStat3) is expressed in numerous cancers and is required for mediating tumorigenesis. Autocrine...Full Text Available

2010-01-01

45

Changes in colonic motility induced by sennosides in dogs: evidence of a prostaglandin mediation.  

UK PubMed Central (United Kingdom)

The effects of sennosides on colonic motility were investigated in eight conscious dogs chronically fitted with two strain gauge transducers in the proximal colon, an intracolonic silicone catheter...Full Text Available

1988-09-01

46

Simulation-based training improves applied clinical placement of ultrasound-guided PICCs  

British Library Electronic Table of Contents (United Kingdom)

Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...

2011-01-01

47

Preparation of AgCl Nanoparticles@Ancient Textile with Antibacterial Activity under Ultrasound Irradiation  

British Library Electronic Table of Contents (United Kingdom)

The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.

2011-01-01

48

First trimester measurements of nasal bone length using three-dimensional ultrasound  

British Library Electronic Table of Contents (United Kingdom)

Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...

2009-01-01

49

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

50

Ultrasound-Guided Three-In-One Nerve Block for Femur Fractures  

UK PubMed Central (United Kingdom)

Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available

2010-09-01

51

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

52

Prediction of the intramuscular fat content in loin muscle of pig carcasses by quantitative time-resolved ultrasound  

British Library Electronic Table of Contents (United Kingdom)

A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...

2012-01-01

53

PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION  

UK PubMed Central (United Kingdom)

Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available

2008-08-01

54

Neoangiogenesis in early cervical cancer: Correlation between color Doppler findings and risk factors. A prospective observational study  

UK PubMed Central (United Kingdom)

BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Doppler ultrasound (TVCD) may predict those prognostic factors...Full Text Available

55

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

56

Kaposi's sarcoma involving the thyroid in a patient with AIDS  

International Nuclear Information System (INIS)

A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.

57

Intravascular ultrasound to guide the management of intracoronary thrombus: a Case Report  

UK PubMed Central (United Kingdom)

Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available

58

Endovascular surgery for peripheral arterial occlusive disease. A critical review.  

UK PubMed Central (United Kingdom)

Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available

1992-07-01

59

Efficacy of ultrasound-guided obturator nerve block in transurethral surgery  

UK PubMed Central (United Kingdom)

Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available

2011-01-01

60

Assessment of the bone quality of black male athletes using calcaneal ultrasound: a cross-sectional study  

UK PubMed Central (United Kingdom)

BackgroundLifestyle, genetics and environmental factors are established determinants of bone density. We aimed to describe the bone characteristics of competitive top-ranked Nigerian...Full Text Available

 
 
 
 
61

A non-invasive technique for standing surgical repair of urinary bladder rupture in a post-partum mare: a case report  

UK PubMed Central (United Kingdom)

An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available

62

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...

2001-07-01

63

Onset of nucleate boiling and onset of fully developed subcooled boiling using pressure transducers signals spectral analysis  

International Nuclear Information System (INIS)

The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

64

Onset of nucleate boiling and onset of fully developed subcooled boiling using pressure transducers signals spectral analysis  

Energy Technology Data Exchange (ETDEWEB)

The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

2001-12-01

65

Experimental compliance calibration for the mixed-mode bending (MMB) specimen  

Energy Technology Data Exchange (ETDEWEB)

A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.

1997-12-31

66

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

67

New Insights into Type II NAD(P)H:Quinone Oxidoreductases  

UK PubMed Central (United Kingdom)

Type II NAD(P)H:quinone oxidoreductases (NDH-2) catalyze the two-electron transfer from NAD(P)H to quinones, without any energy-transducing site. NDH-2 accomplish the turnover of NAD(P)H, regenerating...Full Text Available

2004-12-01

68

Measurement of audible noise from transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.

1981-03-01

69

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...

1995-08-01

70

The influence of ultrasound on the fluoroquinolones antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...

2011-01-01

71

Serial Intravascular Ultrasound Analysis of the Impact of Myocardial Bridge on Neointimal Proliferation After Coronary Stenting in Patients with Acute Myocardial Infarction  

British Library Electronic Table of Contents (United Kingdom)

Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...

2010-01-01

72

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

73

Endoscopic snare papillectomy with biliary and pancreatic stent placement for tumors of the major duodenal papilla  

British Library Electronic Table of Contents (United Kingdom)

Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...

2010-01-01

74

Assessment of Low Quantitative Ultrasound Values of Calcaneus in Chinese Mainland Women  

British Library Electronic Table of Contents (United Kingdom)

Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...

2006-01-01

75

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

77

Early prenatal diagnosis of conjoined twins at 7 weeks and 6 days' gestation with two-dimensional Doppler ultrasound: a case report  

UK PubMed Central (United Kingdom)

This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according...Full Text Available

78

The Brazilian spherical detector: progress and plans  

International Nuclear Information System (INIS)

We are building the Schenberg gravitational wave detector at the Physics Institute of University of Sao Paulo as programmed by the Brazilian Graviton Project. The antenna and its vibration isolation system are already built, and we have made a first cryogenic run for an overall test, in which we measured the antenna mechanical Q (figure of merit). We also have built a 10.21 GHz oscillator with phase noise performance better than -120 dBc at 3.2 kHz to pump an initial CuAl6% two-mode transducer. We plan to prepare this spherical antenna for a first operational run at 4.2 K with a single transducer and an initial target sensitivity of h #approx# 2 x 10"-"2"1 Hz"-"1"/"2 in a 50 Hz bandwidth around 3.2 kHz soon. Here we present details of this plan and some recent results of the development of this project.

2004-03-07

79

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the detectability of these probes. (author).

1991-08-01

80

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex D - Full-scale test of wind turbine blade, using sensors and NDT  

Energy Technology Data Exchange (ETDEWEB)

A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated damage. (au)

2002-05-01

 
 
 
 
81

Nutrition and Physical Activity in Aging, Obesity, and Cancer  

British Library Electronic Table of Contents (United Kingdom)

The liver is a primary target of growth hormone (GH). GH signals are mediated by the transcription factor signal transducer and activator of transcription 5 (STAT5). Here, we focus on recent discoveries about the role of GH-STAT5 signaling in hepatic physiology and pathophysiology. We discuss roles of the GH-STAT5 axis in body growth, lipid metabolism, and the cell cycle pertaining to hepatosteatosis, fibrosis, and hepatocellular carcinoma. Finally, we discuss recent discoveries about the role of GH-STAT5 in sex-specific gene expression and bile acid, steroid, and drug metabolism.

2011-01-01

82

Methods and instruments for nondestructive testing of the anisotropy of the magnetic properties of ferromagnetic sheet materials (review)  

Energy Technology Data Exchange (ETDEWEB)

This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.

1995-04-01

83

Loaded Transducer Fpr Downhole Drilling Component  

Energy Technology Data Exchange (ETDEWEB)

A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.

2005-07-05

84

Acoustic wave device using plate modes with surface-parallel displacement  

Energy Technology Data Exchange (ETDEWEB)

Solid-state acoustic sensors for monitoring conditions at a surface immersed in a liquid and for monitoring concentrations of species in a liquid and for monitoring electrical properties of a liquid are formed by placing interdigital input and output transducers on a piezoelectric substrate and propagating acoustic plate modes therebetween. The deposition or removal of material on or from, respectively, a thin film in contact with the surface, or changes in the mechanical properties of a thin film in contact with the surface, or changes in the electrical characteristics of the solution, create perturbations in the velocity and attenuation of the acoustic plate modes as a function of these properties or changes in them.

1992-01-01

85

Visualization of the salivary glands. CT and MRI  

International Nuclear Information System (INIS)

For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...

86

A comparison of truncated total least squares with Tikhonov regularization in imaging by ultrasound inverse scattering  

International Nuclear Information System (INIS)

For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...

2003-08-07

87

Idiopathic renal hematuria in a military working dog.  

Science.gov (United States)

A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185

1992-10-01

88

Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography  

International Nuclear Information System (INIS)

Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...

2010-08-01

89

Modulation of neuronal differentiation by CD40 isoforms  

International Nuclear Information System (INIS)

Neuron differentiation is a complex process involving various cell-cell interactions, and multiple signaling pathways. We showed previously that CD40 is expressed and functional on mouse and human neurons. In neurons, ligation of CD40 protects against serum withdrawal-induced injury and plays a role in survival and differentiation. CD40 deficient mice display neuron dysfunction, aberrant neuron morphologic changes, and associated gross brain abnormalities. Previous studies by Tone and colleagues suggested that five isoforms of CD40 exist with two predominant isoforms expressed in humans: signal-transducible CD40 type I and a C-terminal truncated, non-signal-transducible CD40 type II. We hypothesized that differential expression of CD40 isoform type I and type II in neurons may modulate neuron differentiation. Results show that adult wild-type, and CD40"-"/"- deficient mice predominantly express CD40 type I and II isoforms. Whereas adult ...

2008-05-02

90

Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems  

Energy Technology Data Exchange (ETDEWEB)

In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been conducted in searching for suitable adjusting methods for the GHPS and on the subsequent effects on the working parameters of the GHPS. Firstly, several methods are compared, and it is found that the method of adjusting the compressor's rotation speed using a transducer is better than the others. Secondly, this method is experimented on a small scale GHPS at frequencies ranging from 30 to 55 Hz. The analysis of the experimental data reveals the relationships between the compressor frequency and other important parameters, such as coefficient of performance, heat capacity, cool capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (Author)

2003-01-01

91

Pineal and photoperiodic influences on fat deposition, pelage, and testicular activity in male meadow voles.  

Science.gov (United States)

Pinealectomy completely prevented gonadal regression as well as reduction in body weight and white adipose tissue content of the gonadal and retroperitoneal fat deposits in male meadow voles transferred from long to short day lengths. Pineal influences on pelage characteristics depended on which parameter was assessed. For instance, the increase in guard hair length observed in short-day control voles was blocked by pinealectomy; however, a similar increase in underhair length was unaffected by removal of the pineal gland. Photoperiod-dependent changes in fat deposition, testicular activity, and guard hair length presumably rely on altered pineal secretory activity to transduce the effects of day length on the neuroendocrine axis; however, mechanisms independent of pineal activity may be capable of mediating photoperiodic control of underhair growth. PMID:2979644

1988-01-01

92

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

93

Flow-induced changes in pial artery compliance registered with a non-invasive method in rabbits  

British Library Electronic Table of Contents (United Kingdom)

Aim: This study was performed: 1) to assess the relationship between blood flow velocity in the internal carotid artery (CBFICA) and pial artery pulsation (cc-TQ) and 2) to evaluate flow-induced changes in pial artery compliance. Methods: Experiments were performed on 10 crossbred male rabbits. Heart rate (HR), blood pressure (BP), left ventricle ejection fraction (LVEF), CBFICA, the systolic-diastolic blood volume fraction in the brain circulation (CBFSDF) and cc-TQ were recorded after glucagon and acetazolamide administration. cc-TQ was measured with near-infrared transillumination back scattering sounding (NIR-T/BSS), LVEF and CBFSDF with gated scintigraphy and BP and CBFICA with electromagnetic pressure and flow transducers, respectively. Doses of drugs were chosen to exert a haemodyna...

2011-01-01

94

Field results using measurement-while-drilling directional systems in Long Beach, California  

Energy Technology Data Exchange (ETDEWEB)

One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.

1981-01-01

95

Experimental modelling of thermal consolidation effects around a high level waste repository  

International Nuclear Information System (INIS)

This report summarizes the results of a research programme which involves the development of a laboratory experimental facility for the simulation and study of hydro-thermo-mechanical processes in saturated geomaterials with low permeability. The experimentation involves a synthetic cement based porous material made of cement grout which possesses permeabilities in the range of dense unfractured sandstones or shale. Specially manufactured pore-pressure transducers were installed within the cylindrical block at locations adjacent to a plane free boundary. The block was saturated with the periodic application of a vacuum. In its saturated state the plane boundary of the block was subjected to heating via a circular heater the temperature of which was maintained constant. The resulting pore pressure generation along with temperature at these locations was monitored continuously. The results of a series of experiments are documented and further extensions to the ...

96

Evaluation of Capiox FX05 Oxygenator With an Integrated Arterial Filter on Trapping Gaseous Microemboli and Pressure Drop With Open and Closed Purge Line  

British Library Electronic Table of Contents (United Kingdom)

Abstract Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass (CPB) because there is a positive correlation between microemboli exposure during CPB and postoperative neurological injury. Thus, minimizing the number of GME delivered to pediatric patients undergoing CPB procedures would lead to better clinical outcomes. In this study, we used a simulated CPB model to evaluate the effectiveness of capturing GME and the degree of membrane pressure drop for a new membrane oxygenator, Capiox Baby FX05 (Terumo Corporation, Tokyo, Japan), which has an integrated arterial filter with open and closed purge line. We used identical components in this study as our clinical CPB circuit. Three emboli detection and classification quantifier transducers were placed at prepump, preoxygena...

2010-01-01

97

Dynamically focussed array  

Energy Technology Data Exchange (ETDEWEB)

An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a continuously varying focus in accordance ...

1981-07-07

98

Chemical sensors based on surface-confined dendrimers  

Energy Technology Data Exchange (ETDEWEB)

The use of dendrimers for preparing chemically sensitive interfaces for detecting volatile organic compounds (VOCs) using surface acoustic wave (SAW) device transducers is described. Specifically, the synthesis of the dendrimers and the means by which they are affixed to SAW devices is discussed, followed by a detailed spectroscopic analysis of the surface-confined dendrimers and a discussion of their interaction with different VOCs. Most of these preliminary experiments focus on dendrimer surface modification using benzoylchloride, which leads to phenyl terminal groups linked to the dendrimer via amide groups. The results of this study lead us to conclude that dendrimers: (1) provide general specificity towards classes of functional groups and are therefore suitable for array-based sensing schemes; (2) are intermediate in structure between monolayers and polymers and exhibit the desirable properties of both; (3) can be straightforwardly attached to the surfaces of ...

1997-10-01

99

Channelrhodopsin-2 gene transduced into retinal ganglion cells restores functional vision in genetically blind rats  

British Library Electronic Table of Contents (United Kingdom)

To test the hypothesis that transduction of the channelrhodopsin-2 (ChR2) gene, a microbial-type rhodopsin gene, into retinal ganglion cells of genetically blind rats will restore functional vision, we recorded visually evoked potentials and tested the experimental rats for the presence of optomotor responses. The N-terminal fragment of the ChR2 gene was fused to the fluorescent protein Venus and inserted into an adeno-associated virus to make AAV2-ChR2V. AAV2-ChR2V was injected intravitreally into the eyes of 6-month-old dystrophic RCS (rdy/rdy) rats. Visual function was evaluated six weeks after the injection by recording visually evoked potentials (VEPs) and testing optomotor responses. The expression of ChR2V in the retina was investigated histologically. We found that VEPs could not b...

2010-01-01

100

Ceramic Materials and Devices  

Science.gov (United States)

Course website from Cambridge on ceramic materials. This site contains eight lectures in PDF format (Adobe Reader required), two question sheets, five practicals (including answers), digital movies and further useful links. "There is a strong relationship between the structure of a material and its physical properties. The properties of a material whether mechanical, electrical, optical or magnetic, determine how it can be used in practical applications. In this course, the focus is on the structure / property relationship for ionic materials with electrical properties utilised in various transducer devices. The materials considered include perovskites, which have special polarisation properties exploited in ferroelectric, pyroelectric and piezoelectric devices. Other oxides, such as zirconia, have structures permitting rapid diffusion of ions, making them suitable for use in sensors, fuel cells and batteries. The scientific principles underlying the properties of ...

2007-02-01

 
 
 
 
101

Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design.  

Science.gov (United States)

For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817

1999-03-20

102

Better machinery monitoring  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses how specialized techniques for machine condition monitoring can help to eliminate false alarms and undetected faults, leading to a truly cost effective predictive maintenance program. It is vital to base the monitoring system on the parameter which will give the most useful information about potential faults and breakdowns. This parameter is generally agreed to be vibration. While oil debris analysis and variations in temperature, geometry and machine speed can all give advance warning of faults, no other parameter can reveal as wide a range of fault types as vibration. The vibration transducers job is to accurately and faithfully convert the vibration into an electric signal for assessment. If this part of the system is weak, reliability will be badly affected. Data integrity is crucial.

1990-07-01

103

Comparison of histological findings and parathyroid scintigraphy in hemodialysis patients with secondary hyperparathyroid glands  

International Nuclear Information System (INIS)

The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...

2005-04-01

104

The use of SMARTeR stents in patients with biliary obstruction  

Energy Technology Data Exchange (ETDEWEB)

AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.

2004-03-01

105

Temperature and time-dependence of the elastic moduli of Pu and Pu-Ga alloys  

International Nuclear Information System (INIS)

In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .

2007-10-11

106

Solid suspension in stirred tanks: UVP measurements and CFD simulations  

British Library Electronic Table of Contents (United Kingdom)

Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.

2011-01-01

107

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)

2009-07-20

108

Perioperative Care of a Child with Transposition of the Great Arteries  

British Library Electronic Table of Contents (United Kingdom)

Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...

2011-01-01

109

MRI imaging of fetal neck masses with airway compromise: utility in delivery planning  

International Nuclear Information System (INIS)

We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)

2001-10-01

110

Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases  

British Library Electronic Table of Contents (United Kingdom)

Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...

2008-01-01

111

Hepatosplenic T-cell lymphoma is a distinct rare entity: Diagnosis by fine-needle aspiration cytology  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.

2011-01-01

112

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...

2002-08-01

113

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

114

Delaying the superficial inferior epigastric artery flap: A solution to the problem of the small calibre of the donor artery  

British Library Electronic Table of Contents (United Kingdom)

Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...

2011-01-01

115

Clinical and metabolic characteristics of polycystic ovary syndrome without polycystic ovary: a pilot study on Chinese women  

British Library Electronic Table of Contents (United Kingdom)

Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...

2008-01-01

116

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry

2005-08-15

117

Tetracycline hydrochloride sclerotherapy; renal, hepatic, ovarian, and perivesical cysts  

Energy Technology Data Exchange (ETDEWEB)

To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the remaining five the cyst ...

2000-11-01

118

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by two radiologists. ...

2002-10-01

119

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The ...

120

Endobronchial ultrasound with transbronchial needle aspiration for restaging the mediastinum in lung cancer  

DEFF Research Database (Denmark)

Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...

2008-01-01

 
 
 
 
121

Conservative treatment options for carpal tunnel syndrome: a systematic review of randomised controlled trials.  

Science.gov (United States)

Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to determine the strength ...

2002-03-01

122

Time-of-Flight Measurements from Eddy Current Tests  

Science.gov (United States)

Data fusion techniques are based on the premise that two or more carefully designed NDE tests are potentially capable of offering additional information concerning the test object relative to what can be garnered from a single test. However, information from a heterogeneous set of transducers cannot be fused unless the data is mapped onto a common `format'. The eddy current method cannot, for example, provide time-of-flight information that can be combined from estimates derived from ultrasonic tests. This paper presents a simple solution to address the problem by employing the so-called Q-transform to relate diffusive fields, such as those generated by eddy current probes, and propagating wave fields generated by ultrasonic NDT sensors. The paper illustrates how the distance between a defect and a source can be extracted from eddy current data generated using carefully selected excitation signals. Numerical results and comparisons with analytical predictions are ...

2003-03-01

123

The neuroimmune-endocrine axis: pathophysiological implications for the central nervous system cytokines and hypothalamus-pituitary-adrenal hormone dynamics  

Scientific Electronic Library Online (English)

Abstract in english Cytokines are molecules that were initially discovered in the immune system as mediators of communication between various types of immune cells. However, it soon became evident that cytokines exert profound effects on key functions of the central nervous system, such as food intake, fever, neuroendocrine regulation, long-term potentiation, and behavior. In the 80's and 90's our group and others discovered that the genes encoding various cytokines and their receptors are e (more) xpressed in vascular, glial, and neuronal structures of the adult brain. Most cytokines act through cell surface receptors that have one transmembrane domain and which transduce a signal through the JAK/STAT pathway. Of particular physiological and pathophysiological relevance is the fact that cytokines are potent regulators of hypothalamic neuropeptidergic systems that maintain neuroendocrine homeostasis and which regulate the body's response to stress. The mechanisms ...

2000-10-01

124

The influence of electromagnetic field irradiated by high-voltage transmission lines on properties of cells.  

Science.gov (United States)

The influence of low-frequency electromagnetic field irradiating by high-voltage transmission lines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmission lines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this electromagnetic field. The spectra of infrared absorption for ...

2005-01-01

125

Review of progress in quantitative NDE. Abstracts  

Energy Technology Data Exchange (ETDEWEB)

The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for UT and EC; process control and material ...

1986-01-01

126

Retrieval of intravascular foreign bodies with goose neck snare  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is highly effective ...

2004-03-01

127

Propagation of guided waves in aircraft structure  

International Nuclear Information System (INIS)

The potential of ultrasonic guided modes for use in global structural health monitoring of aging metallic aircraft can only be realized if the modes selected are able to propagate over a reasonable distance. This work studies the propagation of different modes through fuselage structure by means of mode analysis, finite element modeling and experimental measurement. Beginning with the case of a simple skin panel, the paper examines propagation across a set of structural features representing a typical monocoque fuselage and considers the effect of overlying sealant layers, bonded and sealed joints, paint layers and tapering skin. With the exception of the fundamental symmetric mode at very low frequency, no mode was found that could propagate across all features with an effective attenuation of less than 40 dB/m. This makes global monitoring of a fuselage structure using a sparse array of transducers very difficult. However, more local monitoring is possible and ...

2000-05-23

128

Pressure Fluctuations as a Diagnostic Tool for Fluidized Beds  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project was to investigate the origin of pressure fluctuations in fluidized bed systems. The study assessed the potential for using pressure fluctuations as an indicator of fluidized bed hydrodynamics in both laboratory scale cold-models and industrial scale boilers. Both bubbling fluidized beds and circulating fluidized beds were evaluated. Testing including both cold-flow models and laboratory and industrial-scale combustors operating at elevated temperatures. The study yielded several conclusions on the relationship of pressure fluctuations and hydrodynamic behavior in fluidized beds. The study revealed the importance of collecting sufficiently long data sets to capture low frequency (on the order of 1 Hz) pressure phenomena in fluidized beds. Past research has tended toward truncated data sets collected with high frequency response transducers, which miss much of the spectral structure of fluidized bed hydrodynamics. As a result, many ...

1998-05-01

129

NADP Regulates the Yeast GAL Induction System  

Energy Technology Data Exchange (ETDEWEB)

Transcriptional regulation of the galactose-metabolizing genes in Saccharomyces cerevisiae depends on three core proteins: Gal4p, the transcriptional activator that binds to upstream activating DNA sequences (UASGAL); Gal80p, a repressor that binds to the carboxyl terminus of Gal4p and inhibits transcription; and Gal3p, a cytoplasmic transducer that, upon binding galactose and adenosine 5'-triphosphate, relieves Gal80p repression. The current model of induction relies on Gal3p sequestering Gal80p in the cytoplasm. However, the rapid induction of this system implies that there is a missing factor. Our structure of Gal80p in complex with a peptide from the carboxyl-terminal activation domain of Gal4p reveals the existence of a dinucleotide that mediates the interaction between the two. Biochemical and in vivo experiments suggests that nicotinamide adenine dinucleotide phosphate (NADP) plays a key role in the initial induction event.

2008-01-01

130

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method offers more flexibility than frequency ...

1986-01-01

131

Effect of dissolved oxygen, hydrazine and pH outside the crevice on the galvanic corrosion of support plate alloys  

International Nuclear Information System (INIS)

A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven specimens in the lower flow arm. In addition, a high pressure syringe was used to ...

1985-03-01

132

Development of a methodology to assess organometallic effects on bioenergetic systems  

Energy Technology Data Exchange (ETDEWEB)

A methodology for assessing the impact of subacute concentrations of organometallic agents on bioenergetic and oxidative damage processes in animals, cells and energy transducing subcellular organelles is being developed. Several of the assays are noninvasive and thus lend themselves to human tests. At the whole-animal level we utilize a treadmill chamber where physiological parameters of exercising animals are monitored. These include parameters of whole animals' work performance such as oxygen consumption, carbon dioxide evolution and endurance. Oxidative damage can be monitored in experiments by analyzing expired air of the animals for ethane and n-pentane. These alkanes correlate with lipid peroxidation in vivo. At the cellular and subcellular levels, respiratory activity, lipid peroxidation and free radical species are assayed. Respiratory activity is measured in muscle homogenates and isolated mitochondria using substrates which feed into different ...

1981-06-01

133

[Natural course of asymptomatic gallstone disease].  

Science.gov (United States)

Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...

1993-07-01

134

The safety issues of medical robotics  

International Nuclear Information System (INIS)

In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical ...

2001-08-01

135

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...

136

Percutaneous drainage of abdominal abcess  

Energy Technology Data Exchange (ETDEWEB)

The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. Percutaneous routes that ...

2002-09-01

137

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the ...

2002-01-01

138

Is intraoperative ultrasound (IOUS) still useful for the detection of liver metastases?  

British Library Electronic Table of Contents (United Kingdom)

SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...

2009-01-01

139

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

140

Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging; Flussquantifizierung in Koronar- und Bypassgefaessen mit der MR-Phasenkontrasttechnik  

Energy Technology Data Exchange (ETDEWEB)

Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...

2000-02-01

 
 
 
 
141

The p75"N"T"R tumor suppressor induces cell cycle arrest facilitating caspase mediated apoptosis in prostate tumor cells  

International Nuclear Information System (INIS)

The p75 neurotrophin receptor (p75"N"T"R) is a death receptor which belongs to the tumor necrosis factor receptor super-family of membrane proteins. This study shows that p75"N"T"R retarded cell cycle progression by induced accumulation of cells in G0/G1 and a reduction in the S phase of the cell cycle. The rescue of tumor cells from cell cycle progression by a death domain deleted (#DELTA#DD) dominant-negative antagonist of p75"N"T"R showed that the death domain transduced anti-proliferative activity in a ligand-independent manner. Conversely, addition of NGF ligand rescued retardation of cell cycle progression with commensurate changes in components of the cyclin/cdk holoenzyme complex. In the absence of ligand, p75"N"T"R-dependent cell cycle arrest facilitated an increase in apoptotic nuclear fragmentation of the prostate cancer cells. Apoptosis of p75"N"T"R expressing cells occurred via the intrinsic mitochondrial pathway leading to a sequential caspase-9 and ...

2006-03-24

142

Process-integrated online monitoring of safety-relevant aluminum airbag pressure vessel components for a combined defect detection and material property determination by using contactless NDT (EMUS and EC)  

Energy Technology Data Exchange (ETDEWEB)

Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and sizing (single frequency technique with ...

1999-07-01

143

Field investigation of a wake structure downwind of a VAWT in a windfarm array  

Energy Technology Data Exchange (ETDEWEB)

The effects of upwind turbine wakes on the performance of a FloWind 17-m VAWT were investigated through a series of field experiments conducted at the FloWind windfarm on Cameron Ridge, Tehachapi, California. The field experiment was conducted within a VAWT array consisting of more than nine VAWTs with separations 3D crosswised by 8D downwind (where D is the turbine diameter) in a staggered configuration. The array is the upwind three rows of VAWTS in a total of six rows that are on top of the Cameron Ridge plateau. The terrain features in the vicinity are reasonably regular, with an upslope of 7 deg on the average; however, several local irregularities are present. The annual hourly averaged wind speed exceeds 8 m/s at the site. The wind field and the power-outputs of nine turbines within the array were measured with wind sensors and power transducers. Nine Gill propeller and 18 Maximum cup anemometers and one direction sensor were mounted on portable and stack-up ...

1987-10-01

144

Deliberate ignition of hydrogen-air-steam mixtures in condensing steam environments  

Energy Technology Data Exchange (ETDEWEB)

Large scale experiments were performed to determine the effectiveness of thermal glow plug igniters to burn hydrogen in a condensing steam environment due to the presence of water sprays. The experiments were designed to determine if a detonation or accelerated flame could occur in a hydrogen-air-steam mixture which was initially nonflammable due to steam dilution but was rendered flammable by rapid steam condensation due to water sprays. Eleven Hydrogen Igniter Tests were conducted in the test vessel. The vessel was instrumented with pressure transducers, thermocouple rakes, gas grab sample bottles, hydrogen microsensors, and cameras. The vessel contained two prototypic engineered systems: (1) a deliberate hydrogen ignition system and (2) a water spray system. Experiments were conducted under conditions scaled to be nearly prototypic of those expected in Advanced Light Water Reactors (such as the Combustion Engineering (CE) System 80+), with prototypic spray drop ...

1997-05-01

145

Comparison between experimental data and numerical modeling for the natural circulation phenomenon  

Energy Technology Data Exchange (ETDEWEB)

There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat transfer phenomena. Instrumentation data acquisition is performed through a computer interface developed with LABVIEW. Previous ...

2009-07-01

146

Clinical and ultrasonographic findings, diagnosis and treatment of pyelonephritis in 17 cows.  

Science.gov (United States)

The goal of the present study was to describe the clinical, haematological and ultrasonographic findings and treatment of 17 cattle with pyelonephritis. Fifteen cattle had an abnormal general condition, which varied in severity; five animals had signs of colic. The urine was brownish-red in 11 animals and cloudy in 13. Clumps of purulent material were seen in the urine of nine animals and clots of blood in two. The specific gravity was lower than normal in 13 animals and ranged from 1.005 to 1.020. A urine test strip revealed protein in 16 animals, blood in 16 and leukocytes in 12. Bacteriological examination of urine yielded Corynebacterium renale in 11 animals, Arcanobacter pyogenes in two and Escherichia coli in one. Rectal examination revealed abnormalities of the urinary tract in 11 animals; there was dilatation of the left ureter and/or enlargement of the left kidney in eight cases, and dilatation of the right ureter and/or enlargement of the right kidney in three others. The ...

2007-03-23

147

Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...

2003-06-01

148

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...

149

The value of high-resolution MR-imaging for the staging of malignant lesions of tongue, pharynx and larynx; Klinische Wertigkeit der hochaufloesenden Magnetresonanztomographie beim Staging von Tumoren der Mundhoehle, des Pharynx und des Larynx  

Energy Technology Data Exchange (ETDEWEB)

In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert auf die Bestimmung ...

1994-02-01

150

The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...

2011-04-15

151

Technetium-99m DISIDA hepatobiliary agent in diagnosis of hepatocellular carcinoma: relationship between detectability and tumor differentiation  

Energy Technology Data Exchange (ETDEWEB)

The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did not differ from that observed by 99mTc-sulfur colloid scan or ...

1988-12-01

152

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...

2004-07-01

153

Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two patients with larger ...

2010-08-01

154

Pioglitazone does not affect vascular or inflammatory responses after endotoxemia in humans.  

Science.gov (United States)

PPARgamma agonists have been proposed to exert more than metabolic benefits, particularly by anti-inflammatory mechanisms. We hypothesized that pioglitazone might modulate inflammatory and vascular responses to lipopolysaccharide (LPS). In a placebo-controlled parallel-group study in 18 healthy male subjects, the E. coli endotoxin model of inflammation (20 IU/kg i. v.) was employed to test the effect of 60 mg pioglitazone over nine days on inflammatory cytokines. Macrovascular function and microvascular blood flow were assessed by brachial artery ultrasound and retinal blood flow parameters, respectively. Pioglitazone increased brachial artery diameter by 5.6% but had no effect on other outcome parameters under resting conditions. LPS increased cytokine levels to peak concentrations of 91.3+/-22.5 ng/ml (IL-6), 261.4+/-60.0 ng/ml (TNFalpha), and 524.5+/-15.3 ng/ml (VCAM-1). The endotoxin caused microvascular vasodilation and increased retinal white blood cell flux, ...

2008-05-21

155

Longitudinal changes in extended roles in radiography  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this ...

2002-11-01

156

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen ...

2008-09-15

157

Image-guided pleural biopsy: diagnostic yield and complications  

International Nuclear Information System (INIS)

Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of ...

2006-08-01

158

Clinical Significance of Renal Pelvic Dilatation less than 10 mm in Neonates: Correlation with Urinary Tract Infection and Vesicoureteral Reflux  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the correlation of mild renal pelvic dilatation (RPD) that is observed to be less than 10 mm on ultrasound (US) with urinary tract infection (UTI) and vesicoureteral reflux (VUR) in neonates. We reviewed 137 kidneys of 107 neonates who had RPD less than 10 mm on US. All the kidneys were divided into two groups: Group I (RPD <= 5.0 mm) and Group II (RPD > 5.0 mm), and we statistically analyzed the RPD change according to UTI and VUR. Seven neonates had VUR (5.1%), and there was no statistical significance between Group I (6 neonates, 5.6%) and Group II (1 neonate, 3.3%). Thirty seven cases (27%) had UTI and there was no statistical significance between Group I (30 cases, 28.0%) and Group II (7 cases, 23.3%). The RPD did not change in 81.8% of the cases, it increased in 4.4% of the cases and it decreased in 13.9% of the cases on follow up US. The incidence of VUR and UTI were not different according to the change of RPD. There were ...

2009-12-15

159

Accuracy of single versus combined use of ultrasonography or computed tomography in the localization of parathyroid adenoma  

International Nuclear Information System (INIS)

Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...

160

Design of High-speed Wear Lifetime Tester of the Instrument Ball Bearings  

Energy Technology Data Exchange (ETDEWEB)

The instrument ball bearings are the key components of movable components for various kinds of measuring and control instruments; they often operate in the environmental condition of high-speed and light preload. In general, the non metal, disposable oilimpregnated retainer material has been used for these kinds of high precision miniature bearing. The engineering practice shows that the common failure mode of them is the wear which appears under the condition of insufficient lubrication condition. As the results, the vibration and noise will be enlarged, so does the frictional torque, which makes the ball bearings to lose its original working accuracy. It is the lifetime test of bearings that can enable the designers and manufacturers to chose the material of the bearing properly, optimize the product structure, mend the manufacturing technique process, and to enhance the technical level of the bearing products significantly. In this paper, the wear lifetime tester has been designed ...

2006-10-15

 
 
 
 
161

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv administration of Gd-DTPA. ...

2002-05-01

162

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

163

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The ...

2003-05-01

164

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...

1998-03-01

165

State and development of uterine myoma embolization in Germany; Stand und Entwicklung der Uterusmyomembolisation in Deutschland  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the current situation and implementation of embolization of uterine leiomyomas into the treatment concept in women with symptomatic uterine leiomyomas in Germany. A questionnaire addressing the clinical background of uterine myomas, recommended treatment concepts, preclinical evaluation, technical approach and complications was sent to 164 departments of gynecology and radiology in Germany. 33 radiological departments and 19 gynecological departments submitted a completed questionnaire. Only 7 departments of radiology reported to have own experience with embolization of uterine leiomyomas, while only 2 departments of gynecology considered embolization as an alternative treatment option in patients with symptomatic leiomyomas. 18/33 radiological departments offer this treatment option but get no patient referrals. Agreement was found concerning the indications for treatment, preclinical evaluation by ultrasound and MRI, preferable location of treatable ...

2003-08-01

166

Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoraic 3-dimensional echocardiography; Vergleich der transthorakalen 3D-Echokardiographie mit der MRT zur Bestimmung linksventrikulaerer Volumina bei Patienten mit pathologischer Ventrikelgeometrie aufgrund angeborener Herzfehler  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and ...

2003-07-01

167

Abdominal adipose tissue distribution in obese children. US versus CT measurements; Valutazione della distribuzione del tessuto adiposo addominale nei bambini obesi. Confronto tra ecografia e Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Computed Tomography (CT) and, more recently, ultrasound (US), have proved excellent tools for quantifying adipose tissue distribution. Body fat distribution is an important factor in the treatment of obesity and its complications. In this work it is investigated the correlation between CT and US measurements in pediatric obesity. Forty obese children and adolescents aged 4.1-14.8 years were submitted to CT and US. Intra-abdominal, subcutaneous and total body fat were calculated (in cm{sup 2}), with the CT image analysis software. The rectus muscle-spine and rectus muscle-aorta distances, as indicative of visceral fat thickness, were measured on US images with(out) compression. The distance between skin fat and fat-rectus muscle interfaces was measured as subcutaneous fat thickness. US-CT findings have been compared with other morphometric variables-i.e., patient's (ideal) body weight and skin fold measures. A statistically significant correlation was found ...

1999-12-01