WorldWideScience
1

Intravascular ultrasound to guide the management of intracoronary thrombus: a Case Report  

UK PubMed Central (United Kingdom)

Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available

2

Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases  

British Library Electronic Table of Contents (United Kingdom)

Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...

2008-01-01

3

Percutaneous drainage of abdominal abcess  

Energy Technology Data Exchange (ETDEWEB)

The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the ...

2002-09-01

4

CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections  

International Nuclear Information System (INIS)

The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.

1999-03-01

5

Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors ...

2010-08-01

6

Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea  

UK PubMed Central (United Kingdom)

Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available

2009-06-01

7

Simulation-based training improves applied clinical placement of ultrasound-guided PICCs  

British Library Electronic Table of Contents (United Kingdom)

Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...

2011-01-01

8

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were ...

2001-03-01

9

Ultrasound-Guided Three-In-One Nerve Block for Femur Fractures  

UK PubMed Central (United Kingdom)

Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available

2010-09-01

10

Efficacy of ultrasound-guided obturator nerve block in transurethral surgery  

UK PubMed Central (United Kingdom)

Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available

2011-01-01

11

Integrated Coronary Physiology in Percutaneous Intervention: A new paradigm in interventional cardiology  

British Library Electronic Table of Contents (United Kingdom)

Coronary angiography has provided an unrivalled appreciation of coronary anatomy fostering a far greater appreciation of the extent of atherosclerotic disease. However, the subjectivity of coronary angiography at determining the extent of plaque has been exposed with IVUS. Indices of coronary physiology have provided valuable adjunctive information as to the physiological importance of specific lesions. Fractional flow reserve is an established method for evaluating the significance of epicardial stenoses. Fractional flow reserve guided percutaneous coronary intervention is associated with improved outcomes when compared to a conventional angiographic guided strategy, particularly in intermediate lesions. The use of coronary physiology in the cath lab represents a new avenue to guide appro...

2011-01-01

12

The use of SMARTeR stents in patients with biliary obstruction  

Energy Technology Data Exchange (ETDEWEB)

AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.

2004-03-01

14

Transesophageal echo to help percutaneous closure of ventricular septal defect post acute myocardial infarction  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.

2011-01-01

15

Percutaneous mechanical declotting of thrombosed dialysis graft  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the effectiveness of percutaneous mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Technical success was achieved in 24 of 32 cases, with a procedure time of 30-240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pulmonary embolism. The six-month patency rate was 67.8%. Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpensive, safe and fast, and is well ...

2000-10-01

16

Tetracycline hydrochloride sclerotherapy; renal, hepatic, ovarian, and perivesical cysts  

Energy Technology Data Exchange (ETDEWEB)

To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the ...

2000-11-01

17

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...

2008-11-21

18

Percutaneous US-guided RF thermal ablation for malignant renal tumors: preliminary results in 13 patients  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive treatment for small renal cell carcinoma (RCC) can be necessary in selected patients and, anyway, is desirable. In situ ablation techniques, including RFA, have been developed. The aim of this study is to evaluate the feasibility, safety and short-term local effectiveness of percutaneous US-guided RFA in a small series, as well as mid-term patient outcome. Thirteen patients with a total of 18 tumors (17 small lesions, 35 mm in size or less, and a larger one, 75 mm in size) underwent 19 RFA sessions. Seven patients had a solitary kidney, and three suffered from VHL disease, too. We treated four lesions in a patient with a bilateral tumor. In another patient, three lesions were ablated. Seventeen tumors were RCC; one was a metastasis from lung cancer. Eight lesions were parenchymal, six exophytic, two parenchymal/exophytic, one parenchymal/central and one central. A monopolar RF system with multitined expandable electrode ...

2004-12-01

19

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The ...

2003-05-01

20

Image-guided pleural biopsy: diagnostic yield and complications  

International Nuclear Information System (INIS)

Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A ...

2006-08-01

21

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

22

Hepatosplenic T-cell lymphoma is a distinct rare entity: Diagnosis by fine-needle aspiration cytology  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.

2011-01-01

23

 

Wastenet

guid isPermaLink=\\

24

A Method for Accurate in silico modeling of Ultrasound Transducer Arrays  

UK PubMed Central (United Kingdom)

This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available

2009-05-01

25

Percutaneous endoscopic lumbar discectomy: clinical and quality of life outcomes with a minimum 2 year follow-up  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic lumbar discectomy is a relatively new technique. Very few studies have reported the clinical outcome of percutaneous endoscopic discectomy in terms...Full Text Available

26

Percutaneous duodenostomy - alternative route for enteral nutrition  

International Nuclear Information System (INIS)

Percutaneous translumbar duodenostomy for enteral feeding was performed in one patient with nutritional difficulties. No complication was encountered. The procedure can be an alternative to percutaneous gastrostomy and jejunostomy for enteral feeding in special situations. (orig.).

27

Four Cases of a Cerebral Air Embolism Complicating a Percutaneous Transthoracic Needle Biopsy  

UK PubMed Central (United Kingdom)

A percutaneous transthoracic needle biopsy is a common procedure in the practice of pulmonology. An air embolism is a rare but potentially fatal complication of a percutaneous transthoracic needle biopsy....Full Text Available

2009-01-01

28

The entrepreneur's guide to managing information technology  

CERN Document Server

The entrepreneur's guide to managing information technology

2008-01-01

29

Percutaneous tracheostomy  

UK PubMed Central (United Kingdom)

Background:Percutaneous tracheostomy (PT) has gained an increasing acceptance as an alternative to the conventional surgical tracheostomy (ST). In experienced hands, and with...Full Text Available

1999-01-01

30

Percutaneous renal biopsy as an outpatient procedure.  

UK PubMed Central (United Kingdom)

Percutaneous renal biopsy (PRB) is a safe and effective tool in the diagnosis and management of renal disease. It is the gold standard for evaluating renal parenchymal disease. It is both useful for...Full Text Available

2004-09-01

31

Close to Transplant Renal Artery Stenosis and Percutaneous Transluminal Treatment  

UK PubMed Central (United Kingdom)

Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS)....Full Text Available

2011-01-01

32

Introduction to Javascript  

Science.gov (United States)

Javascript, The Definitive Guide

2009-02-03

37

Endobronchial ultrasound with transbronchial needle aspiration for restaging the mediastinum in lung cancer  

DEFF Research Database (Denmark)

Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...

2008-01-01

38

The safety issues of medical robotics  

International Nuclear Information System (INIS)

In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, ...

2001-08-01

39

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the ...

2002-01-01

40

Ultrasound and airflow induced thermal instability suppression of DC corona discharge: an experimental study  

International Nuclear Information System (INIS)

The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the ...

2006-02-01

41

Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation  

International Nuclear Information System (INIS)

Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying ...

2009-05-01

43

Computerized tomography-guided neurolytic splanchnic nerve block  

International Nuclear Information System (INIS)

Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with severe chronic ...

1997-01-01

44

Ultrasound diagnosis of cephalopagus conjoined twin pregnancy at 29 weeks  

UK PubMed Central (United Kingdom)

The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available

45

Targeted gene transfection from microbubbles into vascular smooth muscle cells using focused, ultrasound-mediated delivery  

UK PubMed Central (United Kingdom)

We investigate a method for gene delivery to vascular smooth muscle cells using ultrasound triggered delivery of plasmid DNA from electrostatically coupled cationic microbubbles. Microbubbles...Full Text Available

2010-09-01

46

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

47

Mid-trimester diagnosis of bladder neck obstruction by ultrasound and paracentesis.  

UK PubMed Central (United Kingdom)

A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available

1983-06-01

48

Correspondence of Ultrasound Elasticity Imaging to Direct Mechanical Measurement in Aging DVT in Rats  

UK PubMed Central (United Kingdom)

Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available

2005-10-01

49

A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis  

UK PubMed Central (United Kingdom)

Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available

2010-04-01

52

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

53

Treatment of large lumbar disc herniation with percutaneous ozone injection via the posterior-lateral route and inner margin of the facet joint  

UK PubMed Central (United Kingdom)

AIM: To evaluate the effects of percutaneous ozone injection via the posterior-lateral route and inner margin of the facet joint in the treatment of large lumbar disc herniation.METHODS:...Full Text Available

2010-03-28

54

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

55

Revisional Percutaneous Full Endoscopic Disc Surgery for Recurrent Herniation of Previous Open Lumbar Discectomy  

UK PubMed Central (United Kingdom)

Study DesignA retrospective study.PurposeTo determine the feasibility and effectiveness of revisional percutaneous full endoscopic discectomy for...Full Text Available

2011-03-01

56

Retrosternal Percutaneous Tracheostomy: An Approach for Predictably Impossible Classic Tracheostomy  

UK PubMed Central (United Kingdom)

Percutaneous tracheostomy is a routine procedure in intensive care units. In cases of very low position of the larynx, cervical spine deformation, morbid obesity, or neck tumor, performance of the classic...Full Text Available

2010-01-01

57

Pyogenic Spondylodiscitis after Percutaneous Endoscopic Lumbar Discectomy  

UK PubMed Central (United Kingdom)

We reviewed 9 cases of pyogenic spondylodiscitis following percutaneous endoscopic lumbar discectomy (PELD). Microbiologic cultures revealed 6 causative organisms. Five patients were managed conservatively...Full Text Available

2010-11-01

58

Pharmacological Prevention of Peri-, and Post-Procedural Myocardial Injury in Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

In recent years, percutaneous coronary intervention (PCI) has become a well-established technique for the treatment of coronary artery disease. PCI improves symptoms in patients with coronary artery...Full Text Available

2008-08-01

59

Percutaneous mitral valve repair: the beginning of the end or the end of the beginning?  

UK PubMed Central (United Kingdom)

The new percutaneous mitral valve repair techniques are at an early stage. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary...Full Text Available

60

Percutaneous endoscopic lumbar discectomy for migrated disc herniation: classification of disc migration and surgical approaches  

UK PubMed Central (United Kingdom)

Percutaneous endoscopic lumbar discectomy (PELD) for migrated disc herniations is technically demanding due to the absence of the technical guideline. The purposes of this study were to propose a radiologic...Full Text Available

2007-03-01

61

Percutaneous core excision and radiofrequency thermo-coagulation for the ablation of osteoid osteoma of the spine  

UK PubMed Central (United Kingdom)

Percutaneous radiofrequency ablation is the treatment of choice for osteoid osteoma of the appendicular skeleton. However, difficulties in localizing the lesion in the spine and its proximity to neural...Full Text Available

2009-03-01

62

Percutaneous absorption of aromatic amines in rubber industry workers: impact of impaired skin and skin barrier creams  

UK PubMed Central (United Kingdom)

BackgroundSeveral aromatic amines (AA) could cause bladder cancer and are an occupational hygiene problem in the workplace. However, little is known about the percutaneous absorption...Full Text Available

2007-06-01

63

Percutaneous Management of a Long Saphenous Vein Graft Aneurysm: A Case Report and Review of Literature  

UK PubMed Central (United Kingdom)

Aneurysms of saphenous vein grafts are rare but can result in complications such as myocardial infarction or death. Percutaneous treatment has included a variety of approaches, including covered stents....Full Text Available

2009-01-01

64

Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve  

UK PubMed Central (United Kingdom)

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available

2010-06-28

65

Outpatient percutaneous coronary intervention: Ready for prime time?  

UK PubMed Central (United Kingdom)

Outpatient practice after percutaneous coronary intervention (PCI) is gaining momentum due to constantly optimizing results. Furthermore, the availability of limited beds to handle the large volume...Full Text Available

2007-10-01

66

Endovascular covered stenting for the management of post-percutaneous nephrolithotomy renal pseudoaneurysm: a case report  

UK PubMed Central (United Kingdom)

IntroductionIntrarenal pseudoaneurysm is a rare, yet clinically significant, complication of percutaneous nephrolithotomy. A high index of clinical suspicion is necessary in order...Full Text Available

67

Echocardiographic assessment and percutaneous closure of multiple atrial septal defects  

UK PubMed Central (United Kingdom)

Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is...Full Text Available

68

Comparison of prasugrel and clopidogrel in patients with acute coronary syndrome undergoing percutaneous coronary intervention  

UK PubMed Central (United Kingdom)

Antiplatelet agents are the cornerstone of treatment for patients with acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI). Clopidogrel, when added to aspirin, has demonstrated...Full Text Available

2009-01-01

69

Comparison of Percutaneous Endoscopic Lumbar Discectomy and Open Lumbar Microdiscectomy for Recurrent Disc Herniation  

UK PubMed Central (United Kingdom)

ObjectiveThe purpose of this study was to compare clinical and radiological outcomes of percutaneous endoscopic lumbar discectomy (PELD) and open lumbar microdiscectomy (OLM) for...Full Text Available

2009-12-01

71

Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...

2003-06-01

72

A PEM's (Program Element Monitors) Survival Guide--The ...  

Science.gov (United States)

... Page 3. REPORT NUMBER 88-0645 TITLE A PEM'S SURVIVAL GUIDE--THE FIRST YEAR ... A PEM'S SURVIVAL GUIDE-THE FIRST YEAR (U) 12. ...

1988-04-01

73

Transurethral Ultrasound Diffraction Tomography  

Science.gov (United States)

... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...

2007-03-01

74

NASA - Get (In) on NASA Innovation!  

Science.gov (United States)

Sep 19, 2011 ... (The whispering voice, on the other hand, was the latest in ultrasound directed audio technology from the firm Audio Spotlight.) The NASA ...

75

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

76

Breast Cancer Treatment  

Medline Plus

... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...

77

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

78

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

79

Joint Task Force Headquarters Master Training Guide.  

Science.gov (United States)

The purpose of the Joint Task Force Headquarters Master Training Guide (JTF HQ MTG) is to provide a descriptive, performance-oriented training guide to assist leaders in training their units. It also serves as a guide for the JTF Headquarters in actual op...

2003-01-01

81
83

Late Life-Threatening Hemorrhage after Percutaneous Tracheostomy  

UK PubMed Central (United Kingdom)

Purpose. Formation of a tracheoinnominate artery fistula (TIF) and consecutive hemorrhage is a rare and life-threatening complication with high mortality. Warning symptoms can...Full Text Available

2011-01-01

84

Cryoanalgesia for intractable perineal pain.  

UK PubMed Central (United Kingdom)

Cryoanalgesia, the local application of extreme cold to nerves to produce analgesia, has been used to treat patients with intractable perineal pain. The cryoprobe was inserted percutaneously through...Full Text Available

1981-11-01

85

A Program Manager's Guide for Software Cost Estimating  

Science.gov (United States)

... A PROGRAM MANAGER'S GUIDE FOR SOFTWARE COST ESTIMATING ... This thesis provides a broad view of the software cost estimating process. ...

2002-12-01

86

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

87

Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available

88

The Risk of Paradoxical Embolism (RoPE) Study: Developing risk models for application to ongoing randomized trials of percutaneous patent foramen ovale closure for cryptogenic stroke  

UK PubMed Central (United Kingdom)

BackgroundDespite the diffusion into practice of percutaneous closure of a patent foramen ovale (PFO) in patients with cryptogenic stroke (CS), the benefits have not been demonstrated,...Full Text Available

89

Huge Psoas Muscle Hematoma due to Lumbar Segmental Vessel Injury Following Percutaneous Endoscopic Lumbar Discectomy  

UK PubMed Central (United Kingdom)

We present a case of an acute psoas muscle hematoma following percutaneous endoscopic lumbar discectomy. A 60-year-old female who presented with far lateral lumbar disc herniation underwent endoscopic...Full Text Available

2009-03-01

90

Suburban amoebiasis. CT and US findings and percutaneous treatment of amoebic liver abscess; Amebiasi sub-urbana: aspetti diagnostici con tomografia computerizzata ed ecografia e trattamento percutaneo degli ascessi amebici del fegato  

Energy Technology Data Exchange (ETDEWEB)

The study reports ultrasonography and computerise tomography findings in 16 patients with amoebic abscesses, 12 of whom lived in a temperate peripheral area north-east of Naples (Italy). All patients have a clinical-diagnostic condition called sub-urban amoebiasis. The personal experience with the US guided therapeutic drainage of amoebic abscess with repeated cavity washing, which is important for positive parasitology. Combined US and CT assessment facilitated the diagnosis of amoebiasis and its differentiation from pyogenic abscess and hepatoma. [Italian] La colonizzazione epatica rappresenta la localizzazione piu' comune dell'amebiasi extraintestinale e gli ascessi epatici ne costituiscono la manifestazione piu' frequente sviluppandosi nel 3-9 % dei pazienti affetti da infezione parassitaria. Diversi studi confermano che la terapia medica dell'amebiasi risulta piu' efficace quando viene associato il drenaggio ...

2000-03-01

91

In vitro examination of the visibility of 11 stent catheters with real-time MR imaging; In-vitro-Untersuchung der Sichtbarkeit von 11 Stentkathetern unter Echtzeit-MR-Kontrolle  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an evaluation of the visibility of the tip of ...

2004-09-01

92

NAME=\\  

Wastenet

...A-Z list of ESDS guides Economic and Social Data Service - User support - ESDS guides | Home | A-Z index ...uk Telephone: +44 (0)1206 872143 Fax: 01206 872003 Print-friendly page A-Z list of ESDS guides Printing tips Printing tips The majority of these guides are web pages with a ... To print these guides at their best: select 'print friendly' at the top-right of the content of the page go to File/...via Beyond 20/20 WDS Advice for new users Analysing Change Over Time: A guide to ESDS resources CommonGIS functionality guide Countries and Citizens: Linking ...

93

Preparation of AgCl Nanoparticles@Ancient Textile with Antibacterial Activity under Ultrasound Irradiation  

British Library Electronic Table of Contents (United Kingdom)

The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.

2011-01-01

94

First trimester measurements of nasal bone length using three-dimensional ultrasound  

British Library Electronic Table of Contents (United Kingdom)

Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...

2009-01-01

95

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

96

FFTF operations procedures preparation guide. Revision 2  

Science.gov (United States)

The Guide is intended to provide guidelines for the initial preparation of FFTF Operating Procedures. The Procedures Preparation Guide was developed from the plan presented and approved in the FFTF Reactor Plant Procedures Plan, PC-1, Revision 3.

1976-12-01

97

32 CFR 552.18 - Administration.  

Science.gov (United States)

...Seeing-eye or guide dogs will remain in guiding...possible agitation of military police working dogs, seeing-eye or guide...allowed in or around working dog kennels and facilities...used for registering military personnel on...

2010-07-01

98

Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride  

Energy Technology Data Exchange (ETDEWEB)

The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

2009-10-15

99

Percutaneous nephrolithotomy for staghorn kidney stones in elderly patients  

British Library Electronic Table of Contents (United Kingdom)

Purpose We retrospectively analyzed the results of percutaneous nephrolithotomy operations for treatment of staghorn kidney stone disease in elderly patients and compared surgical parameters and outcomes with a control group of young adult patients. Patients and method Between 2002 and 2010, 300 consecutive patients underwent percutaneous nephrolithotomy operation for treatment of staghorn kidney stone disease. Forty-five of the patients were older than 65?years and considered to be in elderly group. Thirty-seven of the patients were between the ages 18 and 36?years and considered to be the control group. Surgical parameters and outcomes were compared between groups. Results There were no significant differences between groups for stone area, operation time, difference in hemoglobin levels...

2011-01-01

100

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

101

Prediction of the intramuscular fat content in loin muscle of pig carcasses by quantitative time-resolved ultrasound  

British Library Electronic Table of Contents (United Kingdom)

A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...

2012-01-01

102

PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION  

UK PubMed Central (United Kingdom)

Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available

2008-08-01

103

Neoangiogenesis in early cervical cancer: Correlation between color Doppler findings and risk factors. A prospective observational study  

UK PubMed Central (United Kingdom)

BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Doppler ultrasound (TVCD) may predict those prognostic factors...Full Text Available

104

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

105

Kaposi's sarcoma involving the thyroid in a patient with AIDS  

International Nuclear Information System (INIS)

A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.

106

Endovascular surgery for peripheral arterial occlusive disease. A critical review.  

UK PubMed Central (United Kingdom)

Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available

1992-07-01

107

Assessment of the bone quality of black male athletes using calcaneal ultrasound: a cross-sectional study  

UK PubMed Central (United Kingdom)

BackgroundLifestyle, genetics and environmental factors are established determinants of bone density. We aimed to describe the bone characteristics of competitive top-ranked Nigerian...Full Text Available

108

A non-invasive technique for standing surgical repair of urinary bladder rupture in a post-partum mare: a case report  

UK PubMed Central (United Kingdom)

An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available

109

The 60 Minute Network Security Guide (First Steps Towards a ...  

Science.gov (United States)

... UNCLASSIFIED The 60 Minute Network Security Guide ... 15. SUBJECT TERMS IATAC Collection; information security; network security 16. ...

2001-10-16

110

National Security Agency (NSA) Systems and Network Attack ...  

Science.gov (United States)

... execute the samples The NSA's 60 Minute Network Security Guide [NSA02], part of the Supporting Document guides section ...

2005-03-01

111

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...

2001-07-01

112

Usefulness of thromboaspiration with Desilets-Hoffman sheath in thrombosed hemodialysis access graft  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a Desilets-Hoffman Sheath compared with the previously established percutaneous mechanical thrombectomy technique in cases of occluded dialysis graft. One hundred and sixty eight patients (103 women, 65 men; mean age, 54.7 years; mean graft age, 20.9 months) with 225 episodes of dialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using the crossing catheter or single puncture technique. The technical success rate, procedure time, and complication and patency rates were analyzed. Technical success was achieved in 200 of the 225 procedures (88.9%). The average duration of the intervention was 74.3 {+-} 35 minutes. The primary patency rate was 63.1% at 3 months, 44.2% at 6 months and 26.3% at 1 year. Major complications occurred in 4% of the cases (4 venous ...

2004-07-01

113

Use of clopidogrel in the reduction of myocardial damage during percutaneous coronary intervention  

UK PubMed Central (United Kingdom)

It is estimated that approximately a quarter of patients undergoing coronary intervention may have significant post-procedural creatinine (CK)/creatinine kinase myocardial band (CK-MB) elevations and...Full Text Available

2009-01-01

114

Primary hemifacial spasm: a neurophysiological study.  

UK PubMed Central (United Kingdom)

A series of 53 cases of primary hemifacial spasm have been evaluated by means of blink reflexes and their results compared with a normal control group. Reflex responses were obtained by percutaneous...Full Text Available

1986-01-01

115

Obstructive Jaundice after Bilioenteric Anastomosis: Transhepatic and Direct Percutaneous Enteral Stent Insertion for Afferent Loop Occlusion  

UK PubMed Central (United Kingdom)

Recurrent tumour after radical pancreaticoduodenectomy may cause obstruction of the small bowel loop draining the liver. Roux-loop obstruction presents a particular therapeutic challenge, since the...Full Text Available

2010-09-01

116

New methods of making blocked coronary arteries patent again.  

UK PubMed Central (United Kingdom)

The use of percutaneous transluminal coronary angioplasty is limited by procedural complications and the serious drawback of restenosis, but some new techniques have been developed in an attempt to...Full Text Available

1994-09-03

117

Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine  

UK PubMed Central (United Kingdom)

BackgroundObservational clinical studies have shown that patients with diabetes have less favorable results after percutaneous coronary intervention compared with the non-diabetic...Full Text Available

118

Left Main Coronary Stenosis as a Consequence of Bentall Operation: Percutaneous Treatment  

UK PubMed Central (United Kingdom)

A 65-year-old man suffering from ascending aorta aneurysm and atherosclerotic three vessel disease without left main involvement underwent aortic root replacement with coronary ostia reimplantation...Full Text Available

2009-01-01

119

Health-related quality of life following percutaneous coronary intervention: the impact of age on outcome at 1 year.  

Science.gov (United States)

This study was performed to assess the possibility that patient age may independently affect improvements in health-related quality of life following percutaneous coronary intervention. One hundred five patients undergoing elective percutaneous coronary intervention at a single tertiary referral center between January 10, 2001 and January 6, 2002 were enrolled and prospectively evaluated. Health-related quality of life was assessed before and 1 year following percutaneous coronary intervention using Short Form-12 and the Seattle Angina Questionnaire. For the purpose of analysis, patients were divided according to age (younger than 60, 60-70, and older than 70 years). One hundred patients (95%) completed both questionnaires. Baseline characteristics among the age groups were similar in terms of gender, cardiac risk factors, and procedural details. All health-related quality-of-life indices demonstrated improvements with at ...

120

Drug-Eluting Stents versus Bare Metal Stents in Unprotected Left Main Coronary Artery Stenosis: a Meta-Analysis  

UK PubMed Central (United Kingdom)

ObjectivesWe undertook a meta-analysis to assess outcomes for drug-eluting (DES) and bare metal stents (BMS) in percutaneous coronary intervention (PCI) for unprotected...Full Text Available

2010-06-01

121

Cangrelor increases the magnitude of platelet inhibition and reduces interindividual variability in clopidogrel-pretreated subjects  

UK PubMed Central (United Kingdom)

BackgroundInadequate platelet inhibition despite aspirin and clopidogrel therapy during and after a percutaneous coronary intervention is associated with an impaired clinical outcome....Full Text Available

2009-05-01

122

Abciximab: a reappraisal of its use in coronary care  

UK PubMed Central (United Kingdom)

Platelet reactivity plays a pivotal role in the pathogenesis of ischemic adverse events during and after acute coronary syndromes (ACS), and percutaneous coronary intervention (PCI). Glycoprotein (GP)...Full Text Available

2008-03-01

123

Xyce Parallel Electronic Simulator : reference guide, version 4.1.  

Energy Technology Data Exchange (ETDEWEB)

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide.

2009-02-01

124

Xyce Parallel Electronic Simulator : reference guide, version 2.0.  

Energy Technology Data Exchange (ETDEWEB)

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide.

2004-06-01

127

Radiological equipment for emergencies  

Energy Technology Data Exchange (ETDEWEB)

A brief guide to training and equipment needed to effectively manage victims of radiation accidents. (DT)

1985-01-01

128

Keeping chickens: a beginner's guide : Directgov - Environment and greener living  

Wastenet

...Keeping chickens: a beginner's guide : Directgov - Environment and greener living chickens, feeding chickens, egg marking, registering a ...flock, battery hens Chickens; Department for Environment, Food and Rural Affairs; Registrations; Animals; Livestock; Local government; Local ...authorities A guide for people keeping chickens on the laws for registering and feeding them, and how to spot key diseases. A ...guide for people keeping chickens on the laws for registering and feeding them, and how to spot key diseases. Keeping chickens: ...

133

Interobserver agreement in ultrasonography of the finger and toe joints in rheumatoid arthritis.  

DEFF Research Database (Denmark)

OBJECTIVE: To evaluate the interobserver agreement of ultrasonographic assessment of finger and toe joints in patients with rheumatoid arthritis (RA) by 2 investigators with different medical backgrounds. METHODS: Ultrasonography and clinical examination were performed on 150 small joints of 30 patients with active RA. A General Electric LOGIQ 500 ultrasound unit with a 7-13-MHz linear array transducer was used. In each patient, 5 preselected small joints (second and third metacarpophalangeal, second proximal interphalangeal, first and second metatarsophalangeal) were examined independently on the same day by 2 ultrasound investigators (an experienced musculoskeletal radiologist and a rheumatologist with limited ultrasound training). Joint effusion, synovial thickening, bone erosions, and power Doppler signal were evaluated in accordance with an introduced 4-grade semiquantitative scoring system, on which the investigators ...

2003-01-01

134

The application of 64 multidetector CT angiography in the evaluation of carotid stenosis and follow-up of carotid endarterectomy and percutaneous transluminal stenting  

International Nuclear Information System (INIS)

Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the ...

2006-09-01

135

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...

2007-03-01

136

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...

1995-08-01

137

The influence of ultrasound on the fluoroquinolones antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...

2011-01-01

138

Serial Intravascular Ultrasound Analysis of the Impact of Myocardial Bridge on Neointimal Proliferation After Coronary Stenting in Patients with Acute Myocardial Infarction  

British Library Electronic Table of Contents (United Kingdom)

Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...

2010-01-01

139

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

140

Endoscopic snare papillectomy with biliary and pancreatic stent placement for tumors of the major duodenal papilla  

British Library Electronic Table of Contents (United Kingdom)

Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...

2010-01-01

141

Assessment of Low Quantitative Ultrasound Values of Calcaneus in Chinese Mainland Women  

British Library Electronic Table of Contents (United Kingdom)

Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...

2006-01-01

142

Short rotation coppice: a guide to cold storage of planting material  

Energy Technology Data Exchange (ETDEWEB)

This guide has been written to introduce growers of Short Rotation Coppice (SRC) to the principles and need for cold storage of planting material. The main types of cold store are described. It also provides assistance in the selection of suitable stores and how these are located nationally. (author)

1999-07-01

143

NAME=\\  

Wastenet

...In your area Get connected Farmers & growers news Training & events Poultry (laying) Poultry production can be a profitable enterprise for organic farmers and eggs are ... To find out more about organic poultry production download our free comprehensive introductory guide: Organic poultry production - an introductory guide [PDF, ...

144

Mechanism for breaking up (agglomerate) dams and removal of part of a pitch coke sinter cake  

Energy Technology Data Exchange (ETDEWEB)

The guiding mechanism is attached by a hinge (swivel) to the supporting frame, and the frame is equipped by hinges (swivels) with hydraulic or pneumatic cylinders mounted on its ends and is attached by hinges (swivels) to the coke ejector and guide respectively. This increases the productivity and efficiency of operating the system.

1981-08-23

145

Guided Cell Migration on Microtextured Substrates with Variable Local Density and Anisotropy  

UK PubMed Central (United Kingdom)

This work reports the design of and experimentation with a topographically patterned cell culture substrate of variable local density and anisotropy as a facile and efficient platform to guide...Full Text Available

2009-02-06

146

Intestinal Ischemia for estenosis of the superior mesenteric artery, Treatment with angioplastia and stent implant  

International Nuclear Information System (INIS)

Chronic mesenteric arterial ischemia is an uncommon condition associated a high morbidity and mortality. It is most Commonly caused by atherosclerotic occlusive disease. Patients may suffer epigastric or periumbilical postprandial pain ten to thirty minutes after eating. A case of chronic mesenteric artery stenosis, the diagnosis was performance with colonoscopy and biopsy. We present a case report of a patient with chronic mesenteric ischemia. Mesenteric arteriography was performed and documented estenosis of the mesenteric superior artery. Then percutaneous arteriography with angioplasty and implant of stent was performed. The patients became completely asymptomatic and normal colon mucous is observed in control colonoscopy. The purpose of this report is to present the case endoscopy, clinic and radiological features and to describe the percutaneous angioplasty and implant of stent. We believe that angioplasty treatment offers and improvement ...

147

Update of the Navy Contract Writing Guide  

Science.gov (United States)

... These requirements may be expressed in terms of MIL-STD-2073-1, DoD Material Procedures for Development and Application of Packaging ...

2004-06-01

148

Noncommissioned Officer Education System (NCOES) ...  

Science.gov (United States)

... While some measures were suggested as counseling tools to guide and influence ... it be awarded as part of the NCO Evaluation Report (NCOER). ...

2008-11-01

149

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

151

Hazardous Waste Management on the Farm  

Science.gov (United States)

Sep 2, 2008 ... Abstract: This tutorial is intended to serve as a guide towards proper hazardous waste management. Knowing the regulations, different ...

152

Design Guide: Designing and Building High Voltage Power ...  

Science.gov (United States)

... Aluminum electrolytic capacitors have improved through the years. They are smaller, and equivalent series resistance (ESR) is improved. ...

1988-08-01

153

Return on investment (ROI) proposal preparation guide  

Energy Technology Data Exchange (ETDEWEB)

The ROI Proposal Preparation Guide is a tool to assist Hanford waste generators in preparing ROI proposal forms for submittal to Department of Energy, Richland Operations Office (DOE/RL) for funding. The guide describes the requirements for submitting an ROI proposal and provides examples of completed ROI forms. The intent is to assist waste generators in identifying projects that meet the criteria, provide information necessary to complete the ROI forms, and submit a proposal that is eligible to receive funding.

1998-10-09

154

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

155

Early prenatal diagnosis of conjoined twins at 7 weeks and 6 days' gestation with two-dimensional Doppler ultrasound: a case report  

UK PubMed Central (United Kingdom)

This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according...Full Text Available

156

Study on possible fuel layering sequence for FIREX target  

International Nuclear Information System (INIS)

A new procedure of fuel layering for the Fast Ignition Realization Experiment (FIREX) target is proposed. A conical laser guide heating technique was experimentally demonstrated in principle as the followings. It employed the target consisting of a polystyrene (PS) shell, a fill tube and a conical laser guide. At first, liquid fuel was fed into the shell and existed around the conical laser guide because the surface tension of the fuel must cause it. Then, it was solidified. The laser light provided a heat source to the conical laser guide so that the solid fuel was moved to the other interior of the shell. This process resulted in missing solid fuel around the conical laser guide. To fill the vacant space, liquid fuel was added as temperature was raised to the melting point. After the liquid fuel addition, temperature was lowered to the solidification point again. During this ...

2010-08-01

157

Dispersion of Spilled Heavy Oil by Impinging Waterjet  

Science.gov (United States)

The purpose of this study is to search for a new method of dispersing spilled heavy oil, which has a detrimental effect on the natural environment and marine ecosystem. A method ejecting a waterjet vertically downward to heavy oil on the water surface was studied, particularly focusing on the effect of the guide nozzle shape. The waterjet comprised heavy oil and minute air bubbles, and passed through the hole of the guide nozzle. Thirteen guide nozzle shapes were tested and compared. The dispersion efficiency of a tapered hole was the best among the 13 nozzles. The flow in the hole of the guide nozzles was recorded by a high-speed video camera. The occurrence of two flows, regular and counter flows, was observed in the taper guide nozzle. It seemed that the counter flows generated the shearing force between the waterjet and the heavy oil layer. It is considered that the shearing ...

2009-01-01

158

Use of platelet glycoprotein IIb/IIIa inhibitors in diabetics undergoing PCI for non-ST-segment elevation acute coronary syndromes: impact of clinical status and procedural characteristics  

UK PubMed Central (United Kingdom)

BackgroundThe most recent ESC guidelines for percutaneous coronary intervention (PCI) recommend the use of glycoprotein IIb/IIIa inhibitors (GPI) in high risk patients with non-ST-segment...Full Text Available

2010-06-01

159

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

160

Percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency: efficacy of mechanical thrombectomy with using the stone basket  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the procedural success after percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency and the efficacy of performing mechanical thrombectomy with using the stone basket. From March 2004 to June 2005, 36 thrombosed native hemodialysis access shunts in the upper limbs (brachiocephalic fistulas: 16 and radiocephalic fistulas: 20) were percutaneously treated in 30 patients. Declotting procedures were performed with using urokinase (100,00-200,000 unit) and manual catheter-directed thrombo-aspiration in all the patients. Angioplasty (6 mm in diameter and 4 cm in length) was performed at the identified area of the stenosis and /or with maceration of the thrombus. In 14 cases with massive thrombosis that was refractory to the above mentioned declotting procedures, mechanical thrombectomy with using a Wittich nitinol stone basket (Cook, Bloomington, IN) was performed. Data regarding the procedural ...

2006-06-15

161

Percutaneous intervention in the menagement of insufficient native arteriovenous hemodialysis fistulae  

Energy Technology Data Exchange (ETDEWEB)

To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), artery (n=6), and at the site of anastomosis ...

2002-11-01

162

A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program  

UK PubMed Central (United Kingdom)

BackgroundPaclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation...Full Text Available

163

ASTM residential green building standard guide development  

Energy Technology Data Exchange (ETDEWEB)

The authors have led development of a Standard Guide for Residential Green Buildings through the consensus process of the American Society for Testing and Materials (ASTM). The voluntary guidance document has been processed through two public peer reviews in ASTM`s E-50.06 sub-committee on the environment. The guide`s purpose is to present general criteria for home builders, residential designers and developers on how to systematically approach the creation of a green home--from the design phase on through to eventual de-commissioning of residential structures. This paper briefly reviews the standards process, includes an overview of the Standard Guides` principal criteria, and provides a robust resource listing for further investigation by readers. During development of the Standard Guide, authors emphasized thorough review of the available literature on sustainable residential development. This was ...

1997-12-31

164

Limiting values of radionuclide intake and air concentration and dose conversion factors for inhalation, submersion, and ingestion: Federal guidance report No. 11  

Energy Technology Data Exchange (ETDEWEB)

Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is ...

1988-09-01

165

Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow ...

2001-11-01

166

Visualization of the salivary glands. CT and MRI  

International Nuclear Information System (INIS)

For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...

167

MR imaging of experimental intramuscular hemorrhage at 0. 02 T; Contrast enhancement with Gd-DOTA  

Energy Technology Data Exchange (ETDEWEB)

Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).

1990-09-01

168

A comparison of truncated total least squares with Tikhonov regularization in imaging by ultrasound inverse scattering  

International Nuclear Information System (INIS)

For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...

2003-08-07

169

Safety design guide for pipe rupture protection for CANDU 9  

Energy Technology Data Exchange (ETDEWEB)

This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new.

1996-03-01

170

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

171

Optical guiding measurements on the Mark III free electron laser oscillator  

International Nuclear Information System (INIS)

It has been predicted for several years that light is focused (optically guided) as well as amplified by the electron beam in a free electron laser (FEL). The degree of focusing depends strongly on both electron beam and optical beam characteristics. In an FEL oscillator the degree of focusing varies with intracavity optical power during the macropulse. We report the first direct measurements of the evolution of transverse optical model size and shape between small signal and saturation in a short wavelength (Compton regime) FEL oscillator. The mode measurements on the Mark III FEL oscillator are shown to be consistent with theory, requiring both refractive and gain contributions to guiding. (orig.).

172

MRI survival guide  

International Nuclear Information System (INIS)

The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB)

173

Feasibility study on scheme of disposing spent guide tubes at Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country

1998-12-01

174

Construction: Masonry. Secondary Schools. Curriculum Guide.  

Science.gov (United States)

This construction curriculum guide on masonry for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of instruction; and a listing of references. Concepts covered include orientation to masonry construction, safety, tools and equipment, cement, concrete, concrete block masonry, concrete forms, and concrete reinforcement. Appended materials include transparency copies, tests and answer keys, information sheets, and student activities. (CT)

1980-08-01

175

Idiopathic renal hematuria in a military working dog.  

Science.gov (United States)

A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185

1992-10-01

177

Web Policies & Notices  

Science.gov (United States)

Resources & Guides Schools Airmen Testing FAA Academy Federal Aviation Administration Web Policies & Notices Print Email | Updated: 4:46 pm ET March 2, 2011 Employment...

2011-10-08

178

Washington: a guide to geothermal energy development  

Energy Technology Data Exchange (ETDEWEB)

Washington's geothermal potential is discussed. The following topics are covered: exploration, drilling, utilization, legal and institutional setting, and economic factors of direct use projects. (MHR)

1980-06-01

179

Viewing the Constellations with Binoculars  

CERN Document Server

A guide to practical astronomy. It introduces the reader to some basic (and some not-so-basic) astronomical concepts, and discusses the stars and their evolution, the planets, nebulae, and distant galaxies

2010-01-01

180

User's Guide - NSSDC - NASA  

Science.gov (United States)

F4.1 . MONOTON. Increasing . FILLVAL ... Interface is easier-to-use and requires a much shorter learning curve than the Internal Interface, ...

181

Update of the Navy Contract Writing Guide Phase III  

Science.gov (United States)

... Defense Finance and Accounting Service DID Data Item Descriptions DLA Defense Logistics Agency DLAM Defense Logistics Agency Manual ...

2005-06-01

182

The National Shipbuilding Research Program. Guide to ...  

Science.gov (United States)

... NVIC 3-94, International Maritime Organization Code for the Safe Carriage of Irradiated Nuclear Fuel, Plutonium and High-Level Radioactive ...

1997-10-01

183

Test Planning Guide for ASF Facilities  

Science.gov (United States)

15 to 75% of the gun barrel diameter. Similarly, model masses typically vary from 0.01 to 100 .... taining acceptable levels of gun barrel erosion. The ...

184

Teachers' Guide on Climate Change and Global Warming  

Science.gov (United States)

... Top Ten Things You Need to Know About Global Warming and a note about why there is so ... create your own unit on climate change and global warming."...

185

Recommendations for the prevention of damage to steam turbines. 2. rev. ed.  

International Nuclear Information System (INIS)

The purpose of the recommendation is to prevent, to detect, and to remove soiling of guide and retrating blades of steam turbines, e.g. on account of foreign matter in steam dissolved. (TK/LN).

186

Personnel and Payroll Management; A Guide for the ...  

Science.gov (United States)

... 2. Federal Employees Retirement System (FERS) ... . 17 ... a. Straight and differential pay b. Bcnefits: retirement, sick leave, health insurance ...

1990-06-19

187

Organization of optic lobes that support motion detection in a semiterrestrial crab  

UK PubMed Central (United Kingdom)

There is a mismatch between the documentation of the visually guided behaviors and visual physiology of decapods (Malacostraca, Crustacea) and knowledge about the neural architecture of their...Full Text Available

2005-12-19

188

MST Division Work for Others  

Science.gov (United States)

[[pdf] Reference Guide for Proposals 07/09 [pdf] FY11 Overhead Rate Calculator (xls) DARPA Opportunities NIH Proposals (Leads & Subcontractors) [NIH Office] Related Links MST...

2011-08-27

189

Integrated Optics Interdigitated-Electrode Switches  

Science.gov (United States)

... thus can function as switches -6 ... Akkari, "Optical Channel Waveguide Switch and Coupler ... Wide-Band Guided Wave Acousto-Optic Bragg Diffraction ...

1989-12-31

190

Global Learning and Observations to Benefit the Environment (GLOBE)  

Science.gov (United States)

... s guides and "how-to" videos and other materials, and 7. Receive continuing support from GLOBE's ... and educational materials that result from international proposals in its materials and support ...

191

Cisco Presentation Guide - NASA  

Science.gov (United States)

MilStar,. Globalstar,. Others. DVB. Satellite. Internet. Home Agent. Foreign Agent. Foreign Agent . Reparenting the HA. Primary. Home Agent. Secondary ...

192

COTS GUIDE - Commercial Off-the-Shelf  

Science.gov (United States)

consider applying the requirements of MIL-STD-2073-1. 5.2.5. Sustainability. Because of the design control the. Government has had over. XIL-SPEC designs, ...

193

Benefits Processing Service Delivery Guide - NASA  

Science.gov (United States)

Dec 20, 2007 ... Process 5b Federal Employee Retirement System (FERS) Deposits and ..... CSRS, CSRS Offset, or FERS ..... Advanced Sick Leave and ...

194

A comprehensive assessment of N-terminal signal peptides prediction methods  

UK PubMed Central (United Kingdom)

BackgroundAmino-terminal signal peptides (SPs) are short regions that guide the targeting of secretory proteins to the correct subcellular compartments in the cell. They are cleaved...Full Text Available

195

A Bookshelf in Public Health, Medical Care, and Allied Fields  

UK PubMed Central (United Kingdom)

This bibliography of nonserial publications consists of 610 annotations. It is intended as a guide to the development of a collection for librarians and for health professionals in research and education....Full Text Available

1972-01-01

196

Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography  

International Nuclear Information System (INIS)

Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...

2010-08-01

197

The interventional treatment for biliary re-stenosis after metallic stents placement in patients with malignant obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional treatment for biliary re-stenosis after metallic stents placement in patients due to cholangiocarcinoma and evaluate its therapeutic effect. Methods: Percutaneous metallic stents placement or combined with continuously infusion arterial chemotherapeutic and chemotherapeutic embolization were performed in 12 patients with biliary re-stenosis using 12 metallic stents. Results: Once stent placement was 100% successful in all 12 cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that in preoperation. Jaundice was reduced satisfactorily in 12 patients. 3 patients were undergone continuously arterial chemotherapeutics infusion and chemotherapeutic embolization 4 weeks after stents placement. Conclusions: Percutaneous replacement of biliary metallic stents was effective and safe for palliation of malignant biliary re-stenosis and would be much better when combined with ...

2002-10-01

198

Lipiodol-CT in the detection of tumor persistence in hepatocellular carcinoma treated with percutaneous ethanol injection  

Energy Technology Data Exchange (ETDEWEB)

Our purpose was to investigate the usefulness of Lipiodol-CT for detection of residual viable neoplastic tissue in hepatocellular carcinoma (HCC) lesions treated by means of percutaneous ethanol injection (PEI). An emulsion of 5 to 20 ml iodized oil and 50 to 70 mg doxorubicin hydrochloride was intraarterially injected in 18 patients with 25 HCC lesions treated by means of PEI one to 24 months before. At CT performed 3 to 5 weeks after injection, retention of Lipiodol was observed in 9 of 13 tumors that still contained viable neoplastic tissue and in 2 of 12 tumors proven to have undergone complete necrosis after PEI. The sensitivity and specificity of Lipiodol-CT were 69.2% and 83.3%, respectively. Thus, Lipiodol-CT seems to have limited diagnostic value after PEI, probably as a consequence of the alcohol-induced vascular damage, accounting for both false-negative and false-positive results. (orig.).

1994-07-01

199

Health Related Quality of Life After Percutaneous Coronary Revascularisation in Patients with Previous Coronary Artery Bypass Grafts: A Two-Year Follow Up Study  

British Library Electronic Table of Contents (United Kingdom)

Percutaneous coronary revascularisation [PCR] improves angina and health related quality of life [HRQOL] compared to standard medical therapy. It is unknown whether PCR has the same benefits for patients with a history of CABG. Over a period of 5?years, we assessed HRQOL of patients undergoing PCR using Part 1 of the Nottingham Health Profile [NHP] at baseline 3, 12 and 24?months. We compared HRQOL after PCR in 255 patients with CABG to 2680 without. There were more males [81.1% v 69.6% p?=?0.002] and older patients [mean age 60.1?years v. 58.0 p?=?0.03] in CABG group. Perceived HRQOL improved at 24?months for pain, energy and emotional reaction but the improvement was less in the CABG group. However, mean NHP scores at 24?months for those with CABG had returned to baseline levels for slee...

2011-01-01

200

Effect of percutaneous transluminal angioplasty in insufficiency of arteriovenous fistula for hemodialysis  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the effectiveness of percutaneous transluminal angioplasty(PTA) and to determine the factors affecting the long-term patency rate in the management of insufficient hemodialytic arteriovenous fistula(AVF). Forty-nine cases of insufficient hemodialytic AVF were treated in 44 patients(native AVF:20, graft AVF:29, M:17, F:27, Age:22-70 years). In 28 thrombus patients, thrombolysis was performed with urokinase, and was followed by PTA. The initial success rate and complications of PTA were evaluated. According to the site and length of the stenosis, type and age of the AVF, the presence or abscence of thrombus, a history of diabetic mellitus, the patient's age, and the duration of renal failure, patency rates were compared within each subgroup using the Kaplan-Meier logrank test. The initial success rate of PTA for insufficient hemodialytic AVF was 88%(43/49), the patency rate of PTA was 67% at 6 months, and 50% at 12 months. The initial success ...

1999-06-01

201

CT diagnosis of subphrenic abscess after splenectomy for trauma; Ruolo della tomografia computerizzata nella valutazione degli ascessi subfrenici dopo splenectomia post-traumatica  

Energy Technology Data Exchange (ETDEWEB)

The paper studies subphrenic inflammatory abscesses and splenic fluid collections after splenectomy for trauma. These complications may appear early or late postoperatively; they are easily demonstrated with computerized tomography, which permits accurate spatial assessment of the lesions and appropriate treatment with percutaneous drainage. It has been also investigates the diagnostic accuracy of the CT in subphrenic inflammatory conditions after emergency splenectomy for traumatic spleen rupture and found that CT is a precious tool for rapid and easy diagnosis and follow-up of subphrenic abscesses treated with percutaneous drainage. [Italian] Scopo del lavoro e' di valutare il ruolo della tomografia computerizzata nelle flogrosi subfreniche secondarie a splenectomia d'urgenza per rottura traumatica della milza, documentando come tale metodica risulti accurata nel diagnosticare e monitorare in modo semplice e rapido ...

1999-09-01

202

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures  

International Nuclear Information System (INIS)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...

1999-12-01

203

Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent  

Energy Technology Data Exchange (ETDEWEB)

To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in ...

2002-07-01

204

Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model.  

Science.gov (United States)

Percutaneous osseointegrated prostheses are being investigated as an alternative strategy to attach prosthetic limbs to patients. Although the use of these implants has shown to be promising in clinical trials, the ability to maintain a skin seal around an osseointegrated implant interface is a major challenge to prevent superficial and deep periprosthetic infections. The specific aim of this study was to establish a translational load-bearing ovine model to assess postoperative limb compensation and gait symmetry following a percutaneous osseointegrated implant. We tested the following hypotheses: (1) the animals would return to pre-amputation limb loads within 12-months; (2) the animals would return to a symmetrical gait pattern (stride length and time in stance) within 12-months. The results demonstrated that one month following surgery, the sheep loaded their amputated limb to a mean value of nearly 80% of their pre-amputation loading ...

2011-09-13

205

Technical and economic assessment of computer vision for industrial inspection and robotic assembly  

Energy Technology Data Exchange (ETDEWEB)

The use of computer vision to detect, measure, and perhaps guide the assembly of man-made components is potentially a very significant research and development area. The efficacy of these techniques for any given application depends on both technical and economic considerations. This paper will explore both these considerations using appropriate generic examples. It is our goal to first present a concise discussion of the present state of many technical and economic factors and then extrapolate these factors into the future for the purpose of guiding further investigations.

1981-12-01

206

Quality assurance program requirements (operation)  

International Nuclear Information System (INIS)

Apppendix B of 10 CFR Part 50 establishes quality assurance requirements for the operation of nuclear power plant safety-related structures, systems and components. This Guide describes an acceptable method for complying with these regulations with regard to overall quality assurance program requirements for the operation phase of nuclear power plants. Input to this Guide has been provided by the Advisory Committee on Reactor Safeguards.

207

Quality assurance program requirements (design and construction)  

International Nuclear Information System (INIS)

Appendix B to 10 CFR Part 50 establishes overall quality assurance requirements for the design, construction and operation of safety-related structures, systems, and components. This guide presents a method acceptable to the Commission for complying with these regulations with regard to overall quality assurance program requirements during design and construction of nuclear power plants. Input to this guide has been provided by the Advisory Committee on Reactor Safeguards.

208

Quality assurance during operation of nuclear power plants  

International Nuclear Information System (INIS)

The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.).

209

Nanophotonic components utilizing channel plasmon polaritons  

Science.gov (United States)

Channel plasmon polaritons (CPPs) propagating along the bottom of subwavelength grooves cut into a metal surface were recently shown to exhibit strong confinement combined with low propagation loss, a feature that makes this guiding configuration very promising for the realisation of ultra-compact photonic components. Here, the results of our investigations of CPP guiding by V-grooves cut into gold are presented, demonstrating efficient large-angle bending and splitting of radiation as well as waveguide-ring resonators and Bragg grating filters.

2008-08-01

210

Implementation guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511  

Energy Technology Data Exchange (ETDEWEB)

This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.

1998-04-17

211

Guide to UK renewable energy companies 2001. 6. ed.  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.

212

European Union clean coal technologies. Guide on EC financial support for EU clean coal technology projects outside the EU in the target market  

Energy Technology Data Exchange (ETDEWEB)

This guide is one of the actions following from the recommendations of the Thermie B project that aimed to support the development of a new European Integrated Clean Coal (CCT) Program concept (STR - 1121 - 96), November 1998. The concept aimed to enhance the market deployment of EU CCTs. This guide is prepared for EU industry to help them finding support for their CCT exports to the target markets. The guide will include easy accessible information on the most relevant EC-programs and is intended as a practical tool for EU CCT industry, to assist them in identifying and selecting the export support and programs best able to support their specific export assistance. The guide is a manual (signpost) through the 'jungle of assistance' and therefore does not include extensive information on application procedures, since this kind of information can be easily obtained, once the relevant ...

2000-10-11

213

CCNA Cisco Certified Network Associate Study Guide: Exam 640-801  

CERN Document Server

Here's the book you need to prepare for Cisco's revised CCNA exam, 640-801. This new edition of the best-selling CCNA Study Guide provides in-depth coverage of every CCNA exam objective, practical information on Cisco internetworking solutions and hundreds of challenging review questions.

2006-01-01

214

Abdominal masses in the pediatric age. Characterization by CT guided fine needle aspiration biopsy  

International Nuclear Information System (INIS)

CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age.

1999-04-01

215

Xyce parallel electronic simulator : reference guide.  

Energy Technology Data Exchange (ETDEWEB)

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains ...

2011-05-01

216

Guide to good practices for the development of test items  

Energy Technology Data Exchange (ETDEWEB)

While the methodology used in developing test items can vary significantly, to ensure quality examinations, test items should be developed systematically. Test design and development is discussed in the DOE Guide to Good Practices for Design, Development, and Implementation of Examinations. This guide is intended to be a supplement by providing more detailed guidance on the development of specific test items. This guide addresses the development of written examination test items primarily. However, many of the concepts also apply to oral examinations, both in the classroom and on the job. This guide is intended to be used as guidance for the classroom and laboratory instructor or curriculum developer responsible for the construction of individual test items. This document focuses on written test items, but includes information relative to open-reference (open book) examination test items, as well. These ...

1997-01-01

217

Fundamental study on the convective heat transfer augmentation of a wavy type heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heat exchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting flow guide-plates could not be expected large effects on the heat transfer ...

1988-06-25

218

Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial  

Scientific Electronic Library Online (English)

Abstract in english AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, pati (more) ents' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of ...

2011-01-01

219

Comparison of histological findings and parathyroid scintigraphy in hemodialysis patients with secondary hyperparathyroid glands  

International Nuclear Information System (INIS)

The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...

2005-04-01

220

User's guide for the BNW-III optimization code for modular dry/wet-cooled power plants  

Energy Technology Data Exchange (ETDEWEB)

This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.

1984-09-01

221

Quantization of coupled 1D vector modes in integrated photonic waveguides  

International Nuclear Information System (INIS)

A quantum mechanical analysis of the guided light in integrated photonics waveguides is presented. The analysis is made starting from one-dimensional (1D) guided vector modes by taking into account the modal orthonormalization property on a cross section of an optical waveguide, the vector structure of the guided optical modes and the reversal-time symmetry in order to quantize the 1D vector modes and to derive the quantum momentum operator and the Heisenberg equations. The results provide a quantum-consistent formulation of the linear and nonlinear quantum light propagations as a function of forward and backward creation and annihilation operators in integrated photonics. As an illustration, an application to an integrated nonlinear directional coupler is given, that is, both the nonlinear momentum and the Heisenberg equations of the nonlinear coupler are derived.

2008-06-01

222

Navy Occupational Health Information Management System (NOHIMS). System/Functional Manager's guide  

Energy Technology Data Exchange (ETDEWEB)

This guide is intended to provide the necessary guidance to successfully manage the NAVMED Navy Occupational Health Information Management System (NOHIMS) at NAVMED sites and the NAVSEA Occupational Safety and Health Record Keeping System (OSHRKS) at NAVSEA sites. Outlines procedures to manage system operations, procedures to resolve hardware, software and communications problems, and procedures outside the realm of system operations that are required for a successful system. This guide is intended for the System and Functional Managers use. The System Manager is the individual designated to provide overall ADP management to the entire local configuration. Usually responsible for file backup, daily operations of the CPU, security, supplies, equipment, operating software and technical ADP guidance to the local functional users.

1987-04-01

223

Control device in a reactor  

International Nuclear Information System (INIS)

Purpose: To flatten temperature distribution of coolant within a core. Constitution: The control device of the present invention is to vary reactivity of a fast breeder to control a reactor power. In general, the control device of this kind comprises a guide pipe arranged within the core and a control rod movable up and down within the guide pipe, and a coolant flows from bottom toward top within the guide pipe. Since a cooling flow rate has a margin, temperature of coolant outlet is extremely low as compared to a fuel assembly, and therefore temperature gradient in the vicinity of the top of the control rod becomes sharp to possibly impart thermal shock to the structural material. In the present invention, the flow passage of coolant is varied to thereby avoid outflow thereof into the core, thus flattening the temperature distribution of the coolant within the core. (Kamimura, M.).

224

Block Talk: Spatial Language During Block Play  

British Library Electronic Table of Contents (United Kingdom)

Spatial skills are a central component of intellect and show marked individual differences. There is evidence that variations in the spatial language young children hear, which directs their attention to important aspects of the spatial environment, may be one of the mechanisms that contributes to these differences. To investigate how play affects variations in language, parents and children were assigned to 1 of 3 conditions: free play with blocks, guided play, or play with preassembled structures (Study 1). Parents in the guided play condition produced significantly higher proportions of spatial talk than parents in the other two conditions, and children in the guided play condition produced significantly more spatial talk than those in the free play condition. Study 2 established baseli...

2011-01-01

225

Application of hazard analysis - Critical control point (HACCP) principles to primary production: What is feasible and desirable?  

British Library Electronic Table of Contents (United Kingdom)

We show that the HACCP system is not fully applicable at the primary production level, and that food safety is obtained through the careful implementation of good hygiene practice (GHP) at the farm. Guides to GHP intended at primary productions cover one activity, such as cattle rearing or corn production. Yet most farms have more than one activity. Hazards from one activity can be transferred to another activity, and in general this is not considered in one-activity guides. There is a need therefore for farmers to be able to detect and control such transfers. We suggest a horizontal complement to the Guides to GHP that would consider only the application of the Step 6 and Principle 1 of the HACCP system amended as follows: ''List all potential hazards transferred from one activity to anot...

2011-01-01

226

Temperature and time-dependence of the elastic moduli of Pu and Pu-Ga alloys  

International Nuclear Information System (INIS)

In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .

2007-10-11

227

Solid suspension in stirred tanks: UVP measurements and CFD simulations  

British Library Electronic Table of Contents (United Kingdom)

Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.

2011-01-01

228

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)

2009-07-20

229

Perioperative Care of a Child with Transposition of the Great Arteries  

British Library Electronic Table of Contents (United Kingdom)

Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...

2011-01-01

230

MRI imaging of fetal neck masses with airway compromise: utility in delivery planning  

International Nuclear Information System (INIS)

We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)

2001-10-01

231

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...

2002-08-01

232

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

233

Delaying the superficial inferior epigastric artery flap: A solution to the problem of the small calibre of the donor artery  

British Library Electronic Table of Contents (United Kingdom)

Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...

2011-01-01

234

Clinical and metabolic characteristics of polycystic ovary syndrome without polycystic ovary: a pilot study on Chinese women  

British Library Electronic Table of Contents (United Kingdom)

Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...

2008-01-01

235

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry

2005-08-15

236

Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 ...

2007-10-01

237

Stopping or Reporting Early for Positive Results in Randomized Clinical Trials: The National Cancer Institute Cooperative Group Experience From 1990 to 2005  

UK PubMed Central (United Kingdom)

Randomized clinical trials are designed with stopping boundaries to guide data monitoring committees with their decision making concerning ongoing trials. In particular, when extremely positive results...Full Text Available

2009-04-01

238

Standardization of clinical decision making for the conduct of credible clinical research in complicated medical environments.  

UK PubMed Central (United Kingdom)

The likelihood that past experience will produce correct guides to current practice depends on the signal-to-noise ratio for the clinical problem of interest. If the signal-to-noise ratio is high, the...Full Text Available

1996-01-01

239

Signal and imaging sciences workshop proceedings  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

1997-11-01

240

School-based physical education programs: evidence-based physical activity interventions for youth in Latin America  

UK PubMed Central (United Kingdom)

This article focuses on results of the systematic review from the Guide for Useful Interventions for Activity in Latin America project related to school-based...Full Text Available

2010-06-01

241

Robust principal axes determination for point-based shapes using least median of squares  

UK PubMed Central (United Kingdom)

A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available

2009-04-01

242

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

243

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

244

Quality assurance requirements for packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants (Revision 1) - October 1976  

International Nuclear Information System (INIS)

This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.

245

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

246

Pitfalls with the "chest compression-only" approach: the challenge of an unusual cause  

UK PubMed Central (United Kingdom)

Chest compression-only (CC-only) is now incorporated in the Norwegian protocol for dispatch guided CPR (cardiopulmonary resuscitation) in cardiac arrest of presumed cardiac aetiology.We present...Full Text Available

247

Phase separation, pore structure, and properties of nanofibrous gelatin scaffolds  

UK PubMed Central (United Kingdom)

The development of three-dimensional (3D) biomimetic scaffolds which provide an optimal environment for cells adhesion, proliferation and differentiation, and guide new tissue formation has...Full Text Available

2009-09-01

248

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

249

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

250

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

251

Molecular Ecology of Pyrethroid Knockdown Resistance in Culex pipiens pallens Mosquitoes  

UK PubMed Central (United Kingdom)

Pyrethroid insecticides have been extensively used in China and worldwide for public health pest control. Accurate resistance monitoring is essential to guide the rational use of insecticides and resistance...Full Text Available

252

Mindfulness Research Guide: a New Paradigm for Managing Empirical Health Information  

UK PubMed Central (United Kingdom)

Scientific knowledge of human health continues to grow substantially through publication in empirical journals. These journals, which serve as the warehouses of scientific knowledge, continue...Full Text Available

2010-09-01

253

Metacad programmer's guide  

Energy Technology Data Exchange (ETDEWEB)

Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.

1983-05-01

254

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

255

Learning the Hard Way: Force Protection 1983-2000.  

Science.gov (United States)

The October 2000 terrorist attack on the guided-missile destroyer USS Cole (DDG 67) in the port of Aden, Yemen, is commonly viewed in the larger context of al-Qa'ida's September 11th campaign. Beyond the initial official investigations, the military force...

2009-01-01

256

Laboratory Evaluation of Base Materials for Neutralization of the Contaminated Aquifer at the F-Area Seepage Basins  

Energy Technology Data Exchange (ETDEWEB)

Laboratory studies were performed to support field-testing of base injection into the F-Area Seepage Basins groundwater. The general purpose of these experiments is to provide information to guide the test of base injection and to identify potential adverse effects.

2001-09-11

257

In Vitro Antimicrobial Susceptibilities of Streptococcus pneumoniae Clinical Isolates Obtained in Canada in 2002  

UK PubMed Central (United Kingdom)

Empirical treatment is best guided by current surveillance of local resistance patterns. The goal of this study is to characterize the prevalence of antimicrobial nonsusceptibility within pneumococcal...Full Text Available

2004-09-01

258

Image-guided lumbar facet joint infiltration in nonradicular low back pain  

UK PubMed Central (United Kingdom)

Objective:To assess the efficacy of facet joint infiltrations for pain relief in 44 selected patients with chronic nonradicular low back pain (LBP).Materials...Full Text Available

2009-02-01

259

Image-Guided Convection-Enhanced Delivery Platform in the Treatment of Neurological Diseases  

UK PubMed Central (United Kingdom)

SummaryConvection-enhanced delivery (CED) of substances within the human brain is becoming a more frequent experimental treatment option in the management of brain tumors, and...Full Text Available

2008-01-01

260

Head position modulates optokinetic nystagmus  

UK PubMed Central (United Kingdom)

Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits....Full Text Available

2011-08-01

261

Guidelines on exchangers  

Energy Technology Data Exchange (ETDEWEB)

Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.

1985-08-01

262

Guide to Camouflage for Developers. Volume 1  

Science.gov (United States)

... B I 3 IT TAKES MORE THAN WOODLAND CAMOUFLAGE PAINT! 1X I ... ITEMS/SYSTEMS sm . 4J eo IA''5 FOR CAMOUFLAGE Page 18. SECTION ...

1989-09-01

263

GSFC Information Systems Technology Developments Supporting the Vision for Space Exploration.  

Science.gov (United States)

The Vision for Space Exploration will guide NASA's future human and robotic space activities. The broad range of human and robotic missions now being planned will require the development of new system-level capabilities enabled by emerging new technologie...

2005-01-01

264

From spectral information to animal colour vision: experiments and concepts  

UK PubMed Central (United Kingdom)

Many animals use the spectral distribution of light to guide behaviour, but whether they have colour vision has been debated for over a century. Our strong subjective experience of colour and the fact...Full Text Available

2010-06-07

266

Electromagnetic tracking in the clinical environment  

UK PubMed Central (United Kingdom)

When choosing an electromagnetic tracking system (EMTS) for image-guided procedures several factors must be taken into consideration. Among others these include the system’s refresh rate, the...Full Text Available

2009-03-01

267

ENVI Reference Guide - NASA  

Science.gov (United States)

ADD_MEAN is a floating point number. This value is only used for the LEE filter, ... an averaging filter. This value is only used for the Frost filter, ...... Use this keyword to specify the gaussian sigma value for methods 4 and 5. For ...

268

Cost guide. Volume 6. Cost-estimating methods and techniques  

Energy Technology Data Exchange (ETDEWEB)

There are many requirements for cost analysis and estimating within the Department of Energy (DOE). As projects go through the many stages of planning, source evaluation and selection, contracting, and construction, different estimating requirements exist and different techniques are available to the estimator. This cost guide illustrates how quantity takeoff estimating is performed when adequate design data are available, and it shows how statistics can be applied to obtain parametric cost estimates. Parametric techniques will become increasingly useful as the Department's cost data base and Cost Estimating Relationships (CERs) are developed. Other cost guides developed by the Independent Cost Estimating (ICE) Staff will be published and disseminated soon. The section on parametric cost estimating uses Department of Defense examples since the ICE Staff considered this information to be some of the best available on this subject. Also, ...

1982-05-01

269

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

270

Contrasting Population Structures of the Genes Encoding Ten Leading Vaccine-Candidate Antigens of the Human Malaria Parasite, Plasmodium falciparum  

UK PubMed Central (United Kingdom)

The extensive diversity of Plasmodium falciparum antigens is a major obstacle to a broadly effective malaria vaccine but population genetics has rarely been used to guide vaccine design....Full Text Available

271

Cognitive Expertise, Emotional Development and Reflective Capacity: Clinical Skills for Improved Pain Care  

UK PubMed Central (United Kingdom)

The overarching goal of medical training is to nurture the growth of knowledgeable, caring and insightful clinicians guided by the ideals of medical professionalism. Recent definitions of professional...Full Text Available

2008-11-01

272

Cavitation guide for control valves  

Energy Technology Data Exchange (ETDEWEB)

This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to ...

1993-04-01

273

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

274

Calculation of radon flux attenuation by earthen uranium mill tailings covers  

International Nuclear Information System (INIS)

This regulatory guide describes methods acceptable to the NRC staff for calculating radon fluxes through earthen covers and for calculating the resulting minimum cover thickness needed to meet NRC and EPA standards. The guide also suggests methods for obtaining the various parameters used in calculating the radon fluxes and earthen cover thicknesses and suggests default values for certain parameters. This regulatory guide is applicable to active uranium tailings sites. The NRC staff is using the methods stated in this guide as a basis for review and concurrence of DOE remedial action plans for inactive sites. The guidance is intended to be used for calculating radon flux attenuation by earthen uranium mill tailings covers. The parameter values and examples presented are limited to earthen cover materials, but the diffusion theory and the methods presented are also applicable to man-made materials. ...

2002-02-24

275

Calculation of radon flux attenuation by earthen uranium mill tailings covers  

Energy Technology Data Exchange (ETDEWEB)

This regulatory guide describes methods acceptable to the NRC staff for calculating radon fluxes through earthen covers and for calculating the resulting minimum cover thickness needed to meet NRC and EPA standards. The guide also suggests methods for obtaining the various parameters used in calculating the radon fluxes and earthen cover thicknesses and suggests default values for certain parameters. This regulatory guide is applicable to active uranium tailings sites. The NRC staff is using the methods stated in this guide as a basis for review and concurrence of DOE remedial action plans for inactive sites. The guidance is intended to be used for calculating radon flux attenuation by earthen uranium mill tailings covers. The parameter values and examples presented are limited to earthen cover materials, but the diffusion theory and the methods presented are also applicable to man-made materials. ...

1989-06-01

276

Aging and the Social Cognitive Determinants of Physical Activity Behavior and Behavior Change: Evidence from the Guide to Health Trial  

UK PubMed Central (United Kingdom)

Part one of this study investigated the effect of aging on social-cognitive characteristics related to physical activity (PA) among adults in the baseline phase of a health promotion...Full Text Available

277

A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results  

UK PubMed Central (United Kingdom)

BackgroundHip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly...Full Text Available

278

A Practical Approach to Genetic Inducible Fate Mapping: A Visual Guide to Mark and Track Cells In Vivo  

UK PubMed Central (United Kingdom)

Fate maps are generated by marking and tracking cells in vivo to determine how progenitors contribute to specific structures and cell types in developing and adult tissue. An advance in this...Full Text Available

279

A GUIDE TO THE LITERATURE ON HIGH-VELOCITY ...  

Science.gov (United States)

... Birdsall, DH, Ford, FC, Furth, HP, and Riley, RE, A-2-3-1 "Magnetic Forming! What is it?", American Machinist, 105 (6), 117-121 (March 20, 1961). ...

1962-12-03

280

A College Guide to Disabled Student Services in Washington State.  

Science.gov (United States)

Prepared by volunteers representing a wide range of interests and experience and including students with disabilities, this guide provides basic information about support services available to students with disabilities at public and private postsecondary education institutions in the State of Washington. The guide may also serve as a resource for family members, school counselors and others who assist students in furthering their education. The first section presents general information, discussing students' rights to appropriate education, giving basic rules for managing the transition to college life, charting effects of functional limitations in the academic setting, and providing a planning checklist for new students. Institutional profiles are presented in the second section, covering vocational-technical institutes (5), community colleges (27), and 4-year colleges and universities (16). Information is included on contact person, ...

1986-08-01

281

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

282

49 CFR 221.5 - Definitions.  

Science.gov (United States)

...Colormetric System, which lie within the region bounded by the spectrum locus and lines defined by the following equations: X...intensity of a light in candela as defined by the Illuminating Engineering Society's Guide for Calculating the Effective...

2010-10-01

283

32 CFR 935.40 - Criminal offenses.  

Science.gov (United States)

... (v) Import onto or keep on Wake Island any plant or animal not indigenous to the island, other than military working dogs or a guide dog for the blind or visually-impaired accompanying its owner; or (w) Import or bring onto or...

2010-07-01

284

32 CFR 935.150 - Registration.  

Science.gov (United States)

...1) A privately owned motor vehicle. (2) A privately owned boat. (3) An indigenous animal, military working dog, or guide dog for the blind or visually-impaired accompanying its owner. (4) A narcotic or dangerous drug or...

2010-07-01

285

[Pulmonary vascular manifestations in hereditary hemorrhagic telangiectasia].  

Science.gov (United States)

Hereditary hemorrhagic telangiectasia (Osler-Rendu-Weber disease) is a genetic disorder with autosomal dominance, variable penetrance, and an estimated prevalence of 1/10,000 inhabitants in France. Diagnosis is based on clinical criteria including epistaxis, telangiectasia, visceral manifestations, and familial occurrence. Pulmonary arteriovenous malformations, present in 15-33% of patients, are its primary visceral complications. The disease may be revealed by infectious and ischemic neurological manifestations due to paradoxical embolism. The high frequency of neurologic complications even in asymptomatic patients justifies systematic screening for pulmonary arteriovenous malformations. Treatment of these malformations is based on percutaneous transcatheter coil embolization of the feeding artery. Pulmonary arterial hypertension is rare in this disease. It may be due to systemic arteriovenous shunting in the liver, which increases cardiac output, or be similar to ...

2005-11-01

286

Venous Thoracic Outlet Compression and the Paget-Schroetter Syndrome: A Review and Recommendations for Management  

British Library Electronic Table of Contents (United Kingdom)

Paget Schroetter syndrome, or effort thrombosis of the axillosubclavian venous system, is distinct from other forms of upper limb deep vein thrombosis. It occurs in younger patients and often is secondary to competitive sport, music, or strenuous occupation. If untreated, there is a higher incidence of disabling venous hypertension than was previously appreciated. Anticoagulation alone or in combination with thrombolysis leads to a high rate of rethrombosis. We have established a multidisciplinary protocol over 15?years, based on careful patient selection and a combination of lysis, decompressive surgery, and postoperative percutaneous venoplasty. During the past 10?years, a total of 232 decompression procedures have been performed. This article reviews the literature and presents the Exet...

2011-01-01

287

Treatment of hilar cholangiocarcinoma with inserting biliary double stents  

International Nuclear Information System (INIS)

Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 #+-# 29) #mu#mol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

2004-10-01

288

The interventional treatment for biliary recurrent obstruction after palliative T tube drainage in patients with obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice

2002-10-01

289

Clinical Evaluation of the Zilver Vascular Stent for Symptomatic Iliac Artery Disease  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate the safety and effectiveness of the Zilver vascular stent in the treatment of de novo or restenotic lesions in the external and common iliac arteries.Materials and MethodsRegardless of the results of an initial percutaneous transluminal angioplasty (PTA), 151 consecutive patients were implanted with Zilver vascular stents (Cook, Bloomington, Ind) in up to two stenotic (?10 cm) or occluded (?5 cm) atherosclerotic lesions of the external or common iliac arteries. The primary endpoint was the rate of major adverse events within 9 months after the procedure. Major adverse events were defined as death, myocardial infarction, target lesion revascularization, and limb loss. Secondary endpoints included acute procedural success, 30-day clinical success, 9-month pat...

2008-01-01

290

Chemoradiotherapy of unresectable and recurrent cholangiocarcinoma  

International Nuclear Information System (INIS)

This study is for chemoradiotherapy of unresectable and recurrent cholangiocarcinoma (CCC). Between April 2005 and March 2007, 5 patients were evaluated for unresectable and recurrent CCC. All patients were performed percutaneous transhepatic biliary drainage (PTBD) and treated with chemoradiotherapy. The radiation method was an external beam radiotherapy (EBRT) and remote after loading system (RALS). The chemotherapy was 5-fluorouracil (FU) and gemcitabine by intravenous injection. Three patients had unresectable and 2 had recurrent CCC. As for the side effects, 4 patients had a slight neutropenia and 1 had an uncontrollable gastric bleeding. No patient had cholangitis. The mean survival time for unresectable and recurrent CCC was 13.7 months and 17 months, respectively. Our results indicated that chemoradiotherapy had been consistent with efficacy in patients with unresectable and recurrent CCC. (author)

2007-11-01

291

As time goes by? The fallacy of thrombolysis in STEMI networks  

British Library Electronic Table of Contents (United Kingdom)

Primary percutaneous coronary intervention (PPCI) is superior to thrombolysis (TL) as reperfusion therapy in ST-elevation myocardial infarction (STEMI). TL is a rapidly available, but semi-effective therapy (effective reperfusion in 50% of patients only), whereas PPCI is a potentially delayed, but highly effective therapy (effective reperfusion in >90%). Since TL loses its efficacy beyond 2?3?h after symptom onset, it is a significant reperfusion alternative to PPCI in early presenters only. The individual decision to treat an early presenter with PPCI or TL requires the evaluation of the time delay between potential start of TL or PPCI, the PCI-related delay (PRD). PRD is greatest, if TL is given in the prehospital setting. Until now, prehospital TL as the most rapidly available reperfusi...

2011-01-01

292

Washington: a guide to geothermal energy development  

Energy Technology Data Exchange (ETDEWEB)

A brief overview is given of the geological characteristics of each region of the state as they relate to potential geothermal development. Those exploration methods which can lead to the siting of a deep exploration well are described. Requirements and techniques needed for drilling deeper higher temperature exploration and production wells are presented. Electrical generation, direct utilization, and indirect utilization are reviewed. Economic factors of direct use projects are presented. A general guide to the regulatory framework affecting geothermal energy development is provided. The general steps necessary to gain access to explore, develop, distribute, and use geothermal resources are outlined. (MHR)

1980-01-01

293

PFP Interface identification and management planning guide  

Energy Technology Data Exchange (ETDEWEB)

The purpose of-this planning guide is to present the process used to identify, document, and control PFP Stabilization and Deactivation Project interfaces. Revisions to this document will include, as attachments, the most recent version of the Project Interface Management List. A preliminary Interface Management List is included in Appendix A. This document is intended be a Project owned management tool. As such, this document will periodically require revisions resulting from improvements of the information, processes, and techniques as now described. For most revisions that suggest improved processes, PFP management approval is all that will be required.

1999-05-20

294

Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax)  

International Nuclear Information System (INIS)

Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)

2002-08-01

295

Microwave heating type evaporator  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To prevent evaporization stills against corrosion due to radioactive liquid wastes. Constitution: Microwaves are supplied from a microwave generator by way of a wave guide tube and through a microwave permeation window to the inside of an evaporatization still. A matching device is attached to the wave guide tube for transmitting the microwaves in order to match the impedance. When the microwaves are supplied to the inside of the evaporization still, radioactive liquid wastes supplied from a liquid feed port by way of a spray tower to the inside of the evaporization still is heated and evaporated by the induction heating of the microwaves. (Seki, T.).

1987-01-22

296

Method and apparatus for efficient photodetachment and purification of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ion guide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ion guide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.

2008-02-26

297

Guide to seismic Un{sup *}x (SU) (2). Examples of data processing (1), data input and the preparation of trace headers; Seismic Un{sup *}x (SU) nyumon (2). Deta shori no jutsurei (1), deta nyuryoku to toresu heda no settei  

Energy Technology Data Exchange (ETDEWEB)

A Guide to Seismic Un{sup *} (SU)(2)-Examples of Data Processing(part 1), Data Input and the Preparation of Trace Headers - This is part 1, the preparatory section for the preliminary series for the SU, the two cases of reflectional seismic survey and processing employing the SU, which explains how to input input data from the SEG-Y format tapes and to set trace header. (NEDO)

1999-10-01

298

Engineering guides for estimating cover material thickness and volume for uranium mill tailings  

Energy Technology Data Exchange (ETDEWEB)

Five nomographs have been prepared that facilitate the estimation of cover thickness and cover material volume for the Uranium Mill Tailing Remedial Action Program. Key parameters determined include the cover thickness with either a surface radon flux or a boundary radon air concentration criterion and the total volume of cover material required for two different treatments of the edge slopes. Also included in the engineering guide are descriptions and representative values for the radon source term, the diffusion coefficients and the key meteorological parameters. 16 refs., 7 figs., 2 tabs.

1982-09-01

299

Effective-index modeling of channel plasmon polaritons  

Science.gov (United States)

Effective-index approach is applied for modeling of channel plasmon polaritons (CPPs) propagating in rectangular grooves (trenches) and triangular (V-shaped) grooves in gold, accounting for the main features of CPP guiding and elucidating its underlying physics. The effective indexes of CPP modes along with the corresponding propagation lengths are calculated for different configurations and wavelengths while varying the groove depth. The results obtained allow one to identify the parameter range for realizing the single-mode CPP guiding featuring subwavelength confinement and moderate propagation loss at telecom wavelengths.

2006-10-01

300

Developing with Ext GWT Enterprise RIA Development  

CERN Document Server

Developing in Ext GWT is a fast--paced, practical guide to quickly learning the tasks necessary in building enterprise--class Rich Internet Applications. Based around the exciting new UI library from Ajax leaders Ext JS and the latest GWT release, this book takes the reader through setup, the available widgets, and advanced custom widgets and templates, and concludes with a functional sample client--server application in less than 150 pages. Not your typical beginner's guide to programming, this book provides a rapid approach to becoming effective with leading commercial RIA tools and librarie

2009-01-01

301

Coal export financing: how it is done and who does it. (From the series, Market Guide for Steam Coal Exports from Appalachia)  

Energy Technology Data Exchange (ETDEWEB)

This publication, part of the series titled Market Guide for Steam Coal Exports from Appalachia provides information on export markets, contracts, and related matters for producers and others involved in mining, selling, and shipping Appalachian coal to foreign buyers. It also includes information on the financial institutions that provide export finance and how they are used. Senior officers of more than 40 banks ranged from the largest money center bank and a major foreign bank in New York City to small banks in Appalachia.

1982-11-01

302

CCNA Certification All-In-One For Dummies  

CERN Document Server

A complete preparation guide for the entry-level networking CCNA certification. If you're planning to advance your career by taking the all-important Cisco Certified Network Associate (CCNA), this is the study guide you need! Seven minibooks cover all the concepts and topics on which you'll be tested, covering the latest version of the exam. Each part of the exam is covered thoroughly in its own section, so you can readily find the information you want to study. Plenty of review questions help you prepare, and the companion CD-ROM includes the highly rated Dummies Test Engine so you can test y

2010-01-01

303

Basic Design Report of DC-TOF Inelastic Neutron Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

2006-04-15

304

Alaska: a guide to geothermal energy development  

Energy Technology Data Exchange (ETDEWEB)

A brief overview is given of the geological characteristics of each region of the state as they relate to potential geothermal development. Those exploration methods which can lead to the siting of a deep exploration well are described. Requirements and techniques needed for drilling deeper higher temperature exploration and production wells are presented. Electrical generation, direct utilization, and indirect utilization are reviewed. Economic factors of direct use projects are presented. A general guide to the regulatory framework affecting geothermal energy development is provided. The general steps necessary to gain access to explore, develop, distribute, and use geothermal resources are outlined. (MHR)

1980-06-01

305

The WHO patient safety curriculum guide for medical schools.  

Science.gov (United States)

BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate patient safety learning into existing curriculum. DESIGN: To address this gap and provide a foothold for ...

2010-12-01

306

Republished paper: The WHO patient safety curriculum guide for medical schools.  

Science.gov (United States)

BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate patient safety learning into existing curriculum. DESIGN: To address this gap and provide a foothold for ...

2011-04-01

307

Interventional procedures in superficial lesions: the value of 2D with additional coronal reformatted 4D ultrasonography guidance  

International Nuclear Information System (INIS)

We wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional procedures in superficial lesion. Thirty-three patients were referred for US-guided interventional procedures for superficial lesions, including core biopsy in 19, fine- needle aspriation in eight, therapeutic drug injection in four and needle puncture in two. The procedures were performed under 4D US guidance. We reviewed the pathologic/cytologic results of the core biopsies or needle aspirations, and also the outcomes of drug injection or needle puncture. For all the patients who underwent 4D US-guided core biopsy, the specimens were adequate for making the pathological diagnosis, and specimens were successfully obtained for those patients who underwent 4D US-guided aspiration. The patients treated with 4D ...

2006-03-01

308

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by two radiologists. ...

2002-10-01

309

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The ...

310

Conservative treatment options for carpal tunnel syndrome: a systematic review of randomised controlled trials.  

Science.gov (United States)

Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to determine the strength ...

2002-03-01

311

Percutaneous transluminal angioplasty and thrombolysis in the management of insufficient hemodialysis access: Long-term patency rates and factors affecting patency rates  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the success rates, long-term patency rates and factors affecting the patency rates of percutaneous transluminal angioplasty(PTA) and thrombolysis in the management of insufficient access during hemodialysis. Between January 1991 and March 1995, 37 insufficient shunts(23 native fistulae and 14 graft fistulae) were treated in 31 patients. PTA was performed in 24 shunts, and thrombolysis in 13;in seven of these latter, thrombolysois was followed by PTA. The success and long-term patency rates of PTA and thrombolysis were evaluated. Shunts were subdivided according to a patient's age, type and age of the shunt, and number and length of the stenosis, and the degree of residual stenosis and in each subgroup, patency rates was compared. The overall success rate of PTA and thrombolysis for insufficient hemodialytic access was 78.4%(29/37). The success rates of PTA and thrombolysis were 91.7%(22/24) and 53.8%(7/13), respectively. The patency rates of ...

1997-10-01

312

Percutaneous transluminal angioplasty and stent insertion in central venous steno-occlusion  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) and stent insertion in central venous steno-occlusion. Between August 1992 and January 1998, 11 patients with symptomatic central venous steno-occlusion (six stenoses and five occlusions) underwent pereutaneous treatment. Eleven PTAs were performed and stents were introduced in two patients because of incomplete PTA. During follow-up, a total of eight revisions were performed in five patients with recurrence (six stenoses and two occlusions). Success and long term patency rates were evaluated. The length and degree of the lesion and degree of residual stenosis, as well as pressure gradient through the lesion and decrease of the gradient after PTA, were correlated with patency rates. Complications during the procedures and follow-up period were evaluated. The overall success rate was 89.5%;those of primary and revision intervention were 90. 9% and 87.5%, respectively. Primary and revision ...

1998-12-01

313

Multiscale modeling of transdermal drug delivery  

Science.gov (United States)

This study addresses the modeling of transdermal diffusion of drugs, to better understand the permeation of molecules through the skin, and especially the stratum corneum, which forms the main permeation barrier of the skin. In transdermal delivery of systemic drugs, the drugs diffuse from a patch placed on the skin through the epidermis to the underlying blood vessels. The epidermis is the outermost layer of the skin and can be further divided into the stratum corneum (SC) and the viable epidermis layers. The SC consists of keratinous cells (corneocytes) embedded in the lipid multi-bilayers of the intercellular space. It is widely accepted that the barrier properties of the skin mostly arises from the ordered structure of the lipid bilayers. The diffusion path, at least for lipophilic molecules, seems to be mainly through the lipid bilayers. Despite the advantages of transdermal drug delivery compared to other drug delivery routes such as oral dosing and injections, the low ...

2006-01-01

314

Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation  

International Nuclear Information System (INIS)

Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). ...

2000-09-01

315

A simplified method of opacifying and mixing acrylic cement for percutaneous vertebroplasty: a clinical and in vitro study.  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated with injection of the cement mixture. Complete (CR) ...

316

A Simplified Method of Opacifying and Mixing Acrylic Cement for Percutaneous Vertebroplasty: A Clinical and In Vitro Study  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast{sup TM} 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated with injection of the cement mixture. ...

2005-06-15

317

Development of Guide System for a Reactor Head Maintenance Robot  

Energy Technology Data Exchange (ETDEWEB)

The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address CRD nozzle inspection and repair issues. ...

2005-07-01

318

Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the ...

2008-11-15

319

Rayleigh Laser Guide Star Systems UnISIS Bow Tie Shutter and CCD39 Wavefront Camera  

CERN Document Server

Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie arrangement.

2002-01-01

320

Modified nasolacrimal duct stenting  

International Nuclear Information System (INIS)

Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of ...

2008-06-01

321

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...

2002-06-01

322

LERF Assessment on the AOT changes for Kori 3 and 4 / Yonggwang 1 and 2  

International Nuclear Information System (INIS)

Allowed outage time (AOT), which is required by the technical specification of nuclear power plants (NPPs), has been determined on the basis of deterministic analysis or engineering judgment. AOT is defined as the time for which safety related components can remain inoperable before a plant state is changed. Recently, plants' operating experiences and probabilistic safety assessment (PSA) results show that the AOT could be optimized. Foreign NPPs licensees have changed their technical specifications including AOT using PSA techniques. In 1998, U.S. NRC issued the regulatory guides on risk informed decision-making and technical specification changes, and these are Reg. Guide 1.174, and 1.177. The US NRC accepted AOT extension proposals including the safety injection tank (SIT) and low pressure safety injection system (LPSI) for the ABB-CE designed plants. This paper discusses interim results of AOT changes of the SIT, LPSI, CSS (Containment ...

2007-05-10

323

High efficiency coupling and guiding of intense femtosecond laser pulses in preformed plasma channels in an elongated gas jet  

International Nuclear Information System (INIS)

We report coupling and guiding of pulses of peak power up to 0.3 TW in 1.5 cm long preformed plasma waveguides generated in a high repetition rate argon gas jet. Coupling of up to 52% was measured for 50 mJ, -110 fs pulses injected at times longer than 20 ns, giving guided intensities up to -5x1016 W/cm2. It was found that for short delays between waveguide generation and pulse injection, pulse shortening occurred, with this effect reduced as delay was increased. Injection into the waveguide of two consecutive pulses separated by a few nanoseconds resulted in the reduction of shortening of the second pulse at all delays. Femtosecond time-resolved shadowgrams of the coupling of injected pulses into the waveguide show that there is ?0.5 mm of neutral gas remaining at the waveguide entrance after waveguide generation.

1999-07-12

324

[Natural course of asymptomatic gallstone disease].  

Science.gov (United States)

Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...

1993-07-01

325

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...

326

Is intraoperative ultrasound (IOUS) still useful for the detection of liver metastases?  

British Library Electronic Table of Contents (United Kingdom)

SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...

2009-01-01

327

CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia  

International Nuclear Information System (INIS)

Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were ...

2010-01-01

328

Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging; Flussquantifizierung in Koronar- und Bypassgefaessen mit der MR-Phasenkontrasttechnik  

Energy Technology Data Exchange (ETDEWEB)

Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...

2000-02-01

329

The Application of AHP Model to Guide Decision Makers: A Case Study of E-banking Security  

CERN Document Server

Changes in technology have resulted in new ways for bankers to deliver their services to costumers. Electronic banking systems in various forms are the evidence of such advancement. However, information security threats also evolving along this trend. This paper proposes the application of Analytic Hierarchy Process (AHP) methodology to guide decision makers in banking industries to deal with information security policy. The model is structured according aspects of information security policy in conjunction with information security elements. We found that cultural aspect is valued on the top priority among other security aspects, while confidentiality is considered as the most important factor in terms of information security elements.

2010-01-01

330

Teaching and Learning Guide for: Fairness and Power in Family Organization  

British Library Electronic Table of Contents (United Kingdom)

This guide accompanies the following article: Gabrielle Poeschl, `What Family Organization Tells Us about Fairness and Power in Marital Relationships', Social and Personality Compass 1/1 (2007): 557-571, 10.1111/j.1751-9004.2007.00026.x Author's Introduction One thing that often strikes me, when I talk with people, is the human capacity to accept and defend surprising aspects of the social life. Thus, we have some feeling that the separation between the domestic and the public spheres has not always existed, but we are ready to assume that in the first human groups, men went out hunting to feed their family, while women stayed in the camp to take care of the children. Even in the face of evidence to the contrary, we are reluctant to question the opinion that men and women differ in persona...

2009-01-01

331

Simulation on Impact of Information Guidance on Regional Traffic Flow  

British Library Electronic Table of Contents (United Kingdom)

The traffic flow information guidance can improve the operating efficiency of regional traffic. On the basis of the information guidance model and survey data, this paper takes advantage of the VISSIM software to simulate the traffic in a region within the Southwest Second Ring of Beijing constructed by six roads and six intersections and makes a comparative evaluation on the operation of the regional road traffic flow before and after the implementation of the traffic flow information guidance measures. The analysis of five different guided flow cases shows that if the guided left-turn traffic flows in southbound I.A increases from 10% to 30%, the travel time of the left-turn traffic flow in southbound I.A has a reduction from 18% to 42%, and its delay also reduces from 234 s to 164 s. In...

2008-01-01

332

Hot Cell Facility (HCF) Safety Analysis Report  

Energy Technology Data Exchange (ETDEWEB)

This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important safety functions of each SSC are described. Additionally, information which describes the safety management programs at ...

2000-11-01

333

Federal Geothermal Research Program Update Fiscal Year 1999  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) and its predecessors have conducted research and development (R&D) in geothermal energy since 1971. To develop the technology needed to harness the Nation's vast geothermal resources, DOE's Office of Geothermal and Wind Technologies oversees a network of national laboratories, industrial contractors, universities, and their subcontractors. The following mission and goal statements guide the overall activities of the Office of Geothermal and Wind Technologies. This Federal Geothermal Program Research Update reviews the specific objectives, status, and accomplishments of DOE's Geothermal Program for Federal Fiscal Year (FY) 1999. The information contained in this Research Update illustrates how the mission and goals of the Office of Geothermal and Wind Technologies are reflected in each R&D activity. The Geothermal Program, from its guiding principles to the most detailed ...

2004-02-01

334

An investigation of the thermal performance of an oil filled transformer winding  

Energy Technology Data Exchange (ETDEWEB)

Manufacturers may be required to design transformers to overload specifications. Oil viscosity changes and loss variation with temperature are not accounted for in the industry loading guide. A comprehensive test program was performed using a winding assembly with imbedded thermocouples. Steady state and transient tests were performed for natural and non-directed forced oil circulation. The temperature distribution in the winding was not linear with height as usually assumed. A large number of temperature sensors is required to determine the hot spot location. The location of the hot spot was found to be different and less predictable for natural oil circulation compared with non-directed forced oil circulation especially during overload conditions. This paper reports that improved loading guide equations were developed to account for oil viscosity, resistance change, cooling duct oil rise, and location of the hot spot.

1992-07-01

335

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents ...

1990-07-01

336

Routine upfront abciximab versus standard periprocedural therapy in patients undergoing primary percutaneous coronary intervention for cardiogenic shock: The PRAGUE-7 Study. An open randomized multicentre study  

British Library Electronic Table of Contents (United Kingdom)

Background: The outcome of acute myocardial infarction (AMI) complicated with cardiogenic shock is poor. The aim of this study was to analyse, whether upfront abciximab administration could improve the outcomes of cardiogenic shock. Methods: This multicentre open trial randomized 80 patients with AMI complicated by cardiogenic shock expected to undergo primary PCI into group A (routine upfront-pre-procedural-abciximab bolus followed by 12-h abciximab infusion) and group B (standard therapy). The study primary objective was 30-day combined outcome (death/reinfarction/stroke/new severe renal failure). Results: PCI was technically successful in 90% (A) versus 87.5% (B) patients. Abciximab was used in 100% (A) versus 35% (B). The primary endpoint occurred in 17 group A patients (42.5%) and 11 ...

2011-01-01

337

Retrieval of intravascular foreign bodies with goose neck snare  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is highly effective ...

2004-03-01

338

Percutaneous Treatment of Malignant Jaundice Due to Extrahepatic Cholangiocarcinoma: Covered Viabil Stent Versus Uncovered Wallstents  

International Nuclear Information System (INIS)

To compare clinical effectiveness of Viabil-covered stents versus uncovered metallic Wallstents, for palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, 60 patients were enrolled in a prospective and randomized study. In half of the patients a bare Wallstent was used, and in the other half a Viabil biliary stent. Patients were followed up until death. Primary patency, survival, complication rates, and mean cost were calculated in both groups. Stent dysfunction occurred in 9 (30%) patients in the bare stent group after a mean period of 133.1 days and in 4 (13.3%) patients in the covered stent group after a mean of 179.5 days. The incidence of stent dysfunction was significantly lower in the covered stent group (P = 0.046). Tumor ingrowth occurred exclusively in the bare stent group (P = 0.007). Median survival was 180.5 days for the Wallstent and 243.5 days for the Viabil group (P = 0.039). Complications and mean cost were similar in the two groups. Viabil ...

2010-02-01

339

New stent developments for peripheral arterial occlusive disease; Neue Stententwicklungen fuer die periphere arterielle Verschlusskrankheit  

Energy Technology Data Exchange (ETDEWEB)

Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren ...

2010-01-15

340

Incidence of low bioavailability of leuprolide acetate after percutaneous administration to rats by dissolving microneedles  

British Library Electronic Table of Contents (United Kingdom)

Two-layered dissolving microneedles of which acral portion contained leuprolide acetate (LA) as solid dispersion were prepared with sodium chondroitin sulfate as the base and the systemic absorption efficiency of LA was studied in rats after administration to their abdominal skin. A patch contained 100 dissolving microneedles of which length and basement diameter were 469.8+/-4.7mm and 284.5+/-9.8mm, where LA content was 14.3+/-1.6mg. In vitro dissolution experiment showed that LA was released from dissolving microneedle patch within 3min. LA was stable in the patch, % recoveries for 3 months were 102.2+/-1.9-95.3+/-1.9%. One and half-patch of LA dissolving microneedles were administered to the rat skin and plasma LA concentrations were measured by LC-MS/MS. Plasma LA concentrations increa...

2011-01-01

341

Endoluminal vascular prostheses; Endoluminale Gefaessprothesen  

Energy Technology Data Exchange (ETDEWEB)

Endoluminal vascular prostheses that can be implanted by percutaneous routes represent the most recent development in vascular interventional radiology. Various commercially available types of prosthesis are presented and the construction principles and applications are described. At present secure indications for the implantation of endoluminal prostheses are limited to the elimination of aneurysms and arteriovenous fistulae of the large vessels near the trunk in sections that do not cross a joint. The wide use in peripheral occlusive diseases cannot yet be recommended because confirmed data are not available. (orig.) [German] Endoluminale Gefaessprothesen, die perkutan implantierbar sind, stellen die juengste Entwicklung in der vaskulaeren interventionellen Radiologie dar. Verschiedene kommerziell erhaeltliche Prothesentypen werden vorgestellt, ihr Konstruktionsprinzip und ihre Applikation erlaeutert. Die gesicherten Indikationen zur endoluminalen ...

2000-06-01

342

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and MRCP are virtually ...

2010-07-01

343

Analysis of the placement of multiple metallic stents in the treatment of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the clinical efficacy of multiple stents placement in the management of hilar cholangiocarcinoma, especially in the complex cases of which the hepatic ducts are invaded. Methods: Forty-five consecutive patients with hilar cholangiocarcinoma were treated with percutaneous transhepatic placement of two or three self-expandable metallic endoprostheses. The cause of hilar obstructions in these patients were all cholangiocarcinoma, including Bismuth classification type II (n 12), IIIa (n 17), IIIb (n 10), and IV (n 6). Two or 3 stents were placed in the configuration of T, Y or X over the strictures. Results: Stent placement with 2 or 3 endoprostheses was successful in all patients. All patients showed significant decrease in serum bilirubin level. The mortality rate within 30 days of stent placement was 2.2% (1/45). The mean survival and stent patency times were 215.3 d (26- 516 d) and 181.5 d (26-473 d), respectively. Conclusion: Deploying of ...

2007-11-01

344

Transcutaneous oximetry compared to ankle-brachial-index measurement in the evaluation of percutaneous transluminal angioplasty  

International Nuclear Information System (INIS)

Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the ...

2007-11-01

345

Diagnosis and therapy of Budd-Chiari syndrome; Diagnostik und Therapie des Budd-Chiari-Syndroms  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no ...

1998-09-01

346

enb12441e.pdf  

Wastenet

Each WG has two Co-Chairs and six Vice-Chairs, except WG III, which for the Fifth ...Assessment cycle has three Co-Chairs.The Co-Chairs guide the WGs in fulfilling their ...IN THIS ISSUE A Brief History of the IPCC 1 IPCC-31 Report 3 Approval of the Draft Report of

347

Waste management facilities cost information for hazardous waste. Revision 1  

Energy Technology Data Exchange (ETDEWEB)

This report contains preconceptual designs and planning level life-cycle cost estimates for managing hazardous waste. The report`s information on treatment, storage, and disposal modules can be integrated to develop total life-cycle costs for various waste management options. A procedure to guide the US Department of Energy and its contractor personnel in the use of cost estimation data is also summarized in this report.

1995-06-01

348

Volcano Field Trip  

Science.gov (United States)

This site focuses on the subject of volcanoes, including how volcanoes form, the destruction they can cause, effects of volcanoes on the environment, where active volcanoes are found, volcanoes of other planets, and the different volcano types. Designed as an electronic tour, it guides the user through different web sites and outlines teaching objectives, concepts covered, and new vocabulary. There is a teacher resources section with links for more information, and questions for students to answer along the way.

349

The role of imaging in the choice of correct treatment of unstable thoraco-lumbar fractures  

International Nuclear Information System (INIS)

The concept of unstable burst fracture has been discussed since over 50 years and this injury has received much attention in the literature as regards its radiological diagnosis and clinical treatment. The purpose of this article is to review the way we use imaging to diagnose the injury and to guide treatment.

2006-09-01

350

The characterization of electron beam and its importance  

International Nuclear Information System (INIS)

The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)

2003-07-22

351

The Chicago Handbook for Teachers: A Practical Guide to the College Classroom. Second Edition  

Science.gov (United States)

Those who teach college students have extensive training in their disciplines, but unlike their counterparts at the high school or elementary school level, they often have surprisingly little instruction in the craft of teaching itself. "The Chicago Handbook for Teachers, Second Edition", is an extraordinarily helpful guide for anyone facing the daunting challenge of putting together a course and delivering it successfully. Representing teachers at all stages of their careers, the authors, including distinguished historian Alan Brinkley, offer practical advice for almost any situation a new teacher might face, from preparing a syllabus to managing classroom dynamics. Beginning with a nuts and bolts plan for designing a course, the handbook also explains how to lead a discussion, evaluate your own teaching, give an effective lecture, supervise students' writing and research, create and grade exams, and more. This new edition is thoroughly revised for contemporary ...

2011-06-01

352

Steam turbines. Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In spite of the fact that market requirements for new plants continue to be restricted, steam turbine technology and operation engineers have left nothing undone to improve products and operating characteristics. They are generally guided by the principle of optimum economic power supplies but lowest pollution. The new eastern markets are expected to give new impulses to steam turbine design. Cogeneration is of special future importance. (orig.).

1991-04-01

353

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

354

Safety analysis and license of rod drop time issue at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The rod drop time event of the Daya Bay Nuclear Power Plant is caused by the malfunction of the guide tube developed by Framatome. Three temporary solutions were implemented successively and the long term solution was found in the process of searching for the root cause. The different solutions and the root cause are introduced. The safety analysis and license of the solutions are mainly discussed. Experiences and lessons are drawn by summarizing the important items related to nuclear safety.

355

Quality assurance plan for the Basic Environmental Compliance and Monitoring Program (BECAMP). Revision 1  

Energy Technology Data Exchange (ETDEWEB)

This quality assurance plan (QAP) is designed ensure that the methodologies and the data used for environmental cleanup and treatment studies at the Nevada Test Site are both usable and defensible. The QAP serves two purposes in this regard: (1) to guide the preparation of procedures for carrying out the tasks of the Basic Environmental compliance and Monitoring program (BECAMP); and (2) to help management track the progress of those tasks.

1993-11-01

356

Producing Open Source Software How to Run a Successful Free Software Project  

CERN Document Server

This comprehensive guide offers several tried and true steps to help you successfully manage the complex process of developing free software. Topics include project management, developer motivation, technical infrastructure to support collaboration, and project promotion. Producing Open Source Software is ideal for developers starting their own free software projects, or people who simply want to participate in the process.

2009-01-01

357

MRI survival guide; MRT Basiskurs  

Energy Technology Data Exchange (ETDEWEB)

The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientiation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB) [German] Praktisch jeder Mediziner wird im Laufe seiner Berufstaetigkeit mit der MRT konfrontiert - unabhaengig davon ob in der Radiologie, Orthopaedie, Gynaekologie, Chirurgie, Neurologie oder sonstigen ...

1999-07-01

358

Longitudinal and transverse mode evolution in free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We use the method of Padg approximants and Fourier transform techniques to treat analytically the problem of transverse and longitudinal mode evolution in FELs. We obtain simple relations providing a transparent understanding of the dynamic of pulse propagation effects and of transverse mode guiding. We discuss the interplay with inhomogeneous broadening effects and derive gain formulae including longitudinal and transverse mode couplings.

1995-12-31

359

Interventional Procedures in Superficial Lesions: The Value of 2D with Additional Coronal Reformatted 4D Ultrasonography Guidance  

UK PubMed Central (United Kingdom)

ObjectiveWe wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional...Full Text Available

2006-01-01

360

International water power and dam construction yearbook 1996  

Energy Technology Data Exchange (ETDEWEB)

This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)

1996-12-31

361

Interconnection France-England; Interconnexion France-Angleterre  

Energy Technology Data Exchange (ETDEWEB)

These documents defines the interconnection France-England rules for the 2000 MW DC submarine cable directly linking the transmission networks of England and Wales and France. Rights to use Interconnector capacity from 1 April 2001 are to be offered through competitive tenders and auctions, full details of which are set out in the Rules. The contract and a guide to the application form are provided. (A.L.B.)

2001-07-01

362

High gain 10.6-micron free-electron laser amplifier  

International Nuclear Information System (INIS)

A 10.6-micron wavelength free-electron laser (FEL) amplifier has been operated using a 45-MeV, 600-A electron beam from the Advanced Test Accelerator (ATA) and a 15.36-meter long electromagnetic wiggler. The peak small signal power gain was 27 dB(500). Gain guiding was observed to confine the amplified laser beam.

1988-11-02

363

Hanford Internal Dosimetry Program Manual, PNL-MA-552  

Energy Technology Data Exchange (ETDEWEB)

This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

2009-09-24

364

Geothermal heat pumps - gaining ground in the UK and worldwide  

Energy Technology Data Exchange (ETDEWEB)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

2001-07-01

365

Geothermal heat pumps - gaining ground in the UK and worldwide  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

366

Field guide to the binary stars  

Energy Technology Data Exchange (ETDEWEB)

For most of the history of binary star astronomy, systems have been classified largely on the basis of how they were discovered and qualitative appearance of their spectra and light curves. Present understanding of single and double star evolution has now progressed to the point where most of the classes previously identified, and some new ones, can be arranged into evolutionary sequences, depending primarily on the initial masses and separation of the component stars.

1983-05-12

367

FLUKA: A Multi-Particle Transport Code  

Energy Technology Data Exchange (ETDEWEB)

This report describes the 2005 version of the Fluka particle transport code. The first part introduces the basic notions, describes the modular structure of the system, and contains an installation and beginner's guide. The second part complements this initial information with details about the various components of Fluka and how to use them. It concludes with a detailed history and bibliography.

2005-12-14

368

Energy on the Web  

Energy Technology Data Exchange (ETDEWEB)

Contains Executive Summary and Chapters on: Energy and the Internet; Internet Developments; Search Guide; Oil and Gas Industry; Electricity and Utilities; Nuclear Energy; Coal Industry; Alternative Energy; Government and Supranational Agencies; Research Institutions and Universities; Energy Statistics; Commodity Pricing and financial Markets; Company Information; Country Information; Associations; Engineering; Environment; Patents, Trademarks and Standards; News; Industry Events; Miscellaneous. (Author)

1999-10-01

369

EPA (ENVIRONMENTAL PROTECTION AGENCY) MACROSCOPIC PLANNING MODEL (EPAMAC) FOR STORMWATER AND COMBINED SEWER OVERFLOW CONTROL: APPLICATION GUIDE AND USER'S MANUAL  

Science.gov (United States)

A simplified stormwater management model has been developed to provide an inexpensive, flexible tool for planning and preliminary sizing of stormwater facilities. The model was developed to be part of a methodology for use in the management of stormwater that utilizes both simple...

371

Device for additional compaction of crushed coal loaded into a coke oven  

Energy Technology Data Exchange (ETDEWEB)

This is a patent for a device to increase compaction of the loaded batch in a coking chamber that assures a balanced compaction of the batch from the upper to the bottom layer. The leveling rod has a device on the external end that causes the rod to shift vertically and bring pressure on the material and the pressing attachment. Opposite the loading hoppers of the coking chambers there are guides that ensure the rod will be sunk perpendicularly into the loaded material.

1980-03-26

372

Computed tomography of the chest: A teaching file  

Energy Technology Data Exchange (ETDEWEB)

As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.

1987-01-01

373

Combined heuristic with fuzzy system to transmission system expansion planning  

Energy Technology Data Exchange (ETDEWEB)

A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

2011-01-15

374

Characterization of Adaptive Optics at Keck Observatory  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.

2003-07-24

375

Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects  

CERN Document Server

We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.

2009-01-01

376

COST ESTIMATING TOOLS AND RESOURCES FOR ADDRESSING SITES UNDER THE BROWNFIELDS INITIATIVE (SYSTEMS ANALYSIS BRANCH, SUSTAINABLE TECHNOLOGY DIVISION, NRMRL)  

Science.gov (United States)

EPA's Brownfields Economic Redevelopment Initiative was established to assist states, site planners and other community stakeholders to work together to assess, cleanup and sustainably reuse brownfields sites. EPA has developed a series of guides to help these parties effectively...

377

Annotated bibliography covering generation and use of evaluated cross section uncertainty files  

Energy Technology Data Exchange (ETDEWEB)

Literature references related to definition, generation, and use of evaluated cross section uncertainty (variance-covariance) files are listed with comments intended primarily to guide the reader toward materials of immediate interest. Papers are also cited that cover covariance information for individual experiments and that relate to production and use of multigroup covariance matrices. Titles are divided among several major categories.

1983-03-01

378

Anisotropic many-body effects in the quasiparticle velocity of Nb  

International Nuclear Information System (INIS)

Fermi radii and velocities are determined by deconvoluting de Haas-van Alphen data. Comparison of these data with accurate augmented-plane-wave band-structure results establishes the reliability of the augmented-plane-wave calculations and allows a determination of the anisotropic many-body enhancement factor lambda(k). The Fermi-surface average of 1.33 suggests a large electron-electron contribution. Our anisotropic lambda(k) porvides a detailed test and guide for model calculations of many-body enhancement.

379

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

380

Accommodation : Accommodation, campus and Brighton : ... : University of Sussex  

Wastenet

... Further information For more detailed information on available accommodation, refer to our housing guide At home with us, visit Residential Services, or contact : T +44 (0)1273 678220 E housing@sussex.ac.uk Davidrsquo;s perspective lsquo;When my wife and I decided to study at Sussex, we applied for University accommodation. We were delighted with the lovely self-contained flat on Clifton Road in Brighton that we got via the Housing Office. ...

381

ALARA Center of Technology -- resource guide  

Energy Technology Data Exchange (ETDEWEB)

The purpose is to provide a source of information that can be used to assist personnel in the planning, training, and execution of radiological work using the principles of ALARA. This document is not intended to replace HNF or WHC Control Manual requirements. The ALARA Tools-List provides detailed information on the use and procurement of engineered controls, mockup training guidelines, and good radiological work practices that have been proven to be ALARA.

1998-02-05

382

A guide to choosing a school : Directgov - Parents  

Wastenet

...authority's and schools' prospectuses Finding a school to suit your child School performance: test results and Ofsted reports Applying for a school place Once you ... Finding a school to suit your child School performance: test results and Ofsted reports Applying for a school place: admissions criteria Apply for ...

383

32 CFR Appendix D to Subpart M of... - Unauthorized Activities in Maneuver Training Areas  

Science.gov (United States)

...DEPARTMENT OF THE ARMY MILITARY RESERVATIONS AND...REGULATIONS AFFECTING MILITARY RESERVATIONS ...or guide service, dog training for reimbursement...non-profit organizations working in the public...profit, including dog training for reimbursement...non-profit organizations working in the public...

2010-07-01

384

 

Wastenet

nl/guid /item item titleNieuwe rol overheid nodig voor schone economie/title ...nl/nieuws/nieuwsberichten/2011/nieuwe-rol-overheid-nodig-voor-schone-economie/link description<p>De in de maatschappij ...gt; <a href="/nieuws/persberichten/2011/nieuwe-rol-overheid-nodig-voor-schone-economie">Nieuwe rol overheid nodig voor schone

385

The use of biodegradable polylactic acid barrier materials in the treatment of grade II periodontal furcation defects in humans--Part II: A multicenter investigative surgical study.  

Science.gov (United States)

This study evaluated whether differences in design of 3-dimensional polylactic acid barriers (EPi-Guide and Guidor) would influence hard tissue results in the treatment of Grade II furcations in humans. A multicenter study was conducted, using 40 patients with moderate to advanced bilateral chronic adult periodontitis of the mandibular first or second molars. After flap access, debridement, and root preparation, surgical bone level measurements were taken and membranes were placed on a random basis. Surgical reentry occurred at 1 year. Data collected from all 3 investigative centers were pooled and analyzed using an analysis of variance appropriate for a counterbalancing design. Both barrier materials resulted in significant gains of attachment level and defect reduction. The composite reduction in the vertical component of the osseous defects was greater in the sites treated with Epi-Guide as compared to those treated with Guidor; the ...

1999-02-01

386

The magnetoresonance operation of microwiggler on the piezoelectrics with a strong magnetic guide field  

Energy Technology Data Exchange (ETDEWEB)

We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).

1995-12-31

387

Technology for enhancing chest auscultation in clinical simulation.  

Science.gov (United States)

The ability to use an acoustic stethoscope to detect lung and/or heart sounds, and then to then communicate one's interpretation of those sounds is an essential skill for many medical professionals. Interpretation of lung and heart sounds, in the context of history and other examination findings, often aids the differential diagnosis. Bedside assessment of changing auscultation findings may also guide treatment. Learning lung and heart auscultation skills typically involves listening to pre-recorded normal and adventitious sounds, often followed by laboratory instruction to guide stethoscope placement, and finally correlating the sounds with the associated pathophysiology and pathology. Recently, medical simulation has become an important tool for teaching prior to clinical practice, and for evaluating bedside auscultation skills. When simulating cardiovascular or pulmonary problems, high-quality lung and heart sounds should be able to ...

2011-02-11

388

Robust line width estimation  

Energy Technology Data Exchange (ETDEWEB)

Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. Details concerning the implementation of this ...

1986-07-01

389

Pumps and compressors - buyers` guide 1996/`97; Pumpen und Kompressoren - Einkaufsfuehrer 1996/97  

Energy Technology Data Exchange (ETDEWEB)

The 1996/`97 buyers` guide comprises ten chapters: 1. List of suppliers; 2. Waste management, effluents, sewage systems; 3. Water supply, hydroengineering; 4. Chemistry, petrochemistry; 5. Chemical engineering; 6. Food industry, biotechnology; 7. Paper and cellulose industry; 8. Natural gas industry, natural gas supply; 9. Power plant engineering, power systems, district heating; 10. Air conditioning and refrigeration engineering. (orig.) [Deutsch] Der vorliegende Einkaufsfuehrer 1996/97 ist in zehn Kapiteln gegliedert. Diese sind: 1. Firmenverzeichnis 2-11 2. Entsorgungs-/Abwassertechnik, Klaeranlagen 12-15 3. Wasserversorgung, Wassertechnik 16-18 4. Chemie, Petrochemie 19-22 5. Verfahrenstechnik 23-26 6. Lebensmittelindustrie, Biotechnik 27-29 7. Papier-, Zeluloseindustrie 30-31 8. Erdgasindustrie, -versorgung 32 9. Kraftwerkstechnik, Energieanlagen, Fernwaerme 33-34 10. Kaelte-/Klimatechnik 35-36. (orig.)

1996-12-01

390

Propagation of guided waves in aircraft structure  

International Nuclear Information System (INIS)

The potential of ultrasonic guided modes for use in global structural health monitoring of aging metallic aircraft can only be realized if the modes selected are able to propagate over a reasonable distance. This work studies the propagation of different modes through fuselage structure by means of mode analysis, finite element modeling and experimental measurement. Beginning with the case of a simple skin panel, the paper examines propagation across a set of structural features representing a typical monocoque fuselage and considers the effect of overlying sealant layers, bonded and sealed joints, paint layers and tapering skin. With the exception of the fundamental symmetric mode at very low frequency, no mode was found that could propagate across all features with an effective attenuation of less than 40 dB/m. This makes global monitoring of a fuselage structure using a sparse array of transducers very difficult. However, more local monitoring is possible and ...

2000-05-23

391

Investigation of computational aeroacoustic tools for noise predictions of wind turbine aerofoils  

International Nuclear Information System (INIS)

In this work trailing edge noise levels of a research aerofoil have been computed and compared to aeroacoustic measurements using two different approaches. On the other hand, aerodynamic and aeroacoustic calculations were performed with the full Navier-Stokes CFD code Fluent [Fluent Inc 2005 Fluent 6.2 Users Guide, Lebanon, NH, USA] on the basis of a steady RANS simulation. Aerodynamic characteristics were computed by the aid of various turbulence models. By the combined usage of implemented broadband noise source models, it was tried to isolate and determine the trailing edge noise level. Throughout this work two methods of different computational cost have been tested and quantitative and qualitative results obtained. On the one hand, the semi-empirical noise prediction tool NAFNoise [Moriarty P 2005 NAFNoise User's Guide. Golden, Colorado, July. http://wind.nrel.gov/designcodes/ simulators/NAFNoise] was used to directly predict trailing edge ...

2007-07-01

392

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

393

GUIDE : Unifying Evolutionary Engines through a Graphical User Interface  

CERN Document Server

Many kinds of Evolutionary Algorithms (EAs) have been described in the literature since the last 30 years. However, though most of them share a common structure, no existing software package allows the user to actually shift from one model to another by simply changing a few parameters, e.g. in a single window of a Graphical User Interface. This paper presents GUIDE, a Graphical User Interface for DREAM Experiments that, among other user-friendly features, unifies all kinds of EAs into a single panel, as far as evolution parameters are concerned. Such a window can be used either to ask for one of the well known ready-to-use algorithms, or to very easily explore new combinations that have not yet been studied. Another advantage of grouping all necessary elements to describe virtually all kinds of EAs is that it creates a fantastic pedagogic tool to teach EAs to students and newcomers to the field.

2003-01-01

394

Farm Business Management Analysis: Adjusting the Farm Business to Increase Profit. Unit III. Volume 15, Number 3. Instructor's Guide.  

Science.gov (United States)

Designed primarily for Missouri vocational agricultural instructors participating in the Farm Business Management Analysis Program, this instructor's guide, consisting of 10 lessons, deals with adjusting a farm business to increase profits. The following topics are covered in the individual lessons: law and the farm family, planning income tax management, closing the record book and planning cash flow, evaluating family living expenses, determining the most profitable livestock enterprise, determining the most profitable cropping system, planning the farm marketing program, adjusting capital investments to increase net profit, planning for efficient labor use, and controlling costs. Included in each section are suggestions for a review of previous materials covered, an objective, motivational techniques, key points to be addressed in the lesson, information to be introduced during the lesson, guidelines for holding a group discussion, conclusions, end-of-class ...

1982-06-01

395

Eco-profiling Inco Limited production : a case study  

Energy Technology Data Exchange (ETDEWEB)

Inco Ltd., a primary producer of nickel and an important producer of copper, cobalt, precious metals and sulphur products, initiated a project in 1997 to conduct eco-profiles of its worldwide metal production in an effort to improve its internal processing, marketing and environmental management. The study made it possible to recognize some internal and external benefits including the opportunity to gain operating efficiencies and improved process/product design, the development of better environmental performance indicators to guide decision making, and the availability of comprehensive product related environmental data to meet the informational needs of customers, designers, engineers and governments. This paper described the life cycle assessment (LCA) process used by Inco to conduct the study. A life cycle inventory (LCI) was used to quantitatively calculate resource requirements and environmental burdens associated with a product system over the life cycle of ...

2000-07-01

396

Device for removing drilling fines from a well head  

Energy Technology Data Exchange (ETDEWEB)

The device for removing drilling fines from the well head includes a support disk encompassing the sucker rod of the drilling machine with frame made in the form of a dish with inner conical surface, and overturned truncated cone located in the dish of the support disk with the formation between them of a ring guide slit. In order to improve the effectiveness of removing the drilling fines and convenience of operation by excluding heavy manual auxiliary operations to clean the well head and to move the device from one well to another, it is equipped with a mechanism for suspension with a drive. The inner conical surface of the dish is equipped with slide blocks, while the overturned truncated cone is equipped with projections. The suspension mechanism is made in the form of a hydrocylinder and two pairs of levers connected in pairs by means of hinges. The hinges of each pair of levers are connected to the hydrocylinder, and the levers are hinged to the machine ...

1982-01-01

397

Correct implementation of the Argonne QuickSite{sup SM} process for preremedial site investigations  

Energy Technology Data Exchange (ETDEWEB)

Expedited site characterization (ESC), developed by Argonne National Laboratory, is an interactive, integrated process emphasizing the use of existing data of sufficient quality, multiple complementary characterization methods, and on-site decision making to optimize environmental site investigations. The Argonne ESC is the basis for the provisional ESC standard guide of the ASTM (American Society for Testing and Materials). QuickSite{sup SM} is the implementation package developed by Argonne to facilitate ESC of sites contaminated with hazardous wastes. At various sites, Argonne has successfully implemented QuickSite{sup SM} and demonstrated the technical superiority of the ESC process over traditional methodologies guided by statistics and random-sampling approaches. A key feature in the success of QuickSite{sup SM} investigations is achieving an understanding of the subsurface geologic and hydrogeologic controls and processes at a site ...

1997-10-01

398

Calculating ac/dc resistance ratios for high-pressure oil-filled cable Designs. Volume 1. Designer's guide. Final report  

Energy Technology Data Exchange (ETDEWEB)

Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables with concentric stranded copper conductors and also for cables with aluminum or copper segmental conductors ...

1985-04-01

399

BNFL Report Glass Formers Characterization  

Energy Technology Data Exchange (ETDEWEB)

The objective of this task was to obtain powder property data on candidate glass former materials, sufficient to guide conceptual design and estimate the cost of glass former handling facilities as requested under Part B1 of BNFL Technical and Development Support. Twenty-nine glass forming materials were selected and obtained from vendors for the characterization of their physical properties, durability in caustic solution, and powder flow characteristics. A glass former was selected based on the characterization for each of the ten oxide classes required for Envelope A, B, and C mixtures. Three blends (A, B, and C) were prepared based on formulations provided by Vitreous State Laboratory and evaluated with the same methods employed for the glass formers. The properties obtained are presented in a series of attached Tables. It was determined that five of the ten glass formers, (kyanite, iron oxide, titania, zircon, and zinc oxide) have the potential to cause some ...

2000-07-27

400

Advanced Neutron Source: Plant Design Requirements. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents ...

1990-07-01

401

Abdominal masses in the pediatric age. Characterization by CT guided fine needle aspiration biopsy; Masse addominali nell'eta' pediatrica. Caratterizzazione mediante biopsia computerizzata con ago sottile guidata con Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age. [Italian] Sono noti i vantaggi che la biopsia percutanea con ago sottile guidato con TC puo' apportare per la diagnosi delle lesioni espansive addominali, soprattutto se confrontata con procedure piu' invasive come la laparatomia esplorativa. Questo tipo di metodica e' attalmente poco utilizzato nel caso di pazienti pediatrici a causa della scarsa collaborazione e dei rischi associati. Gli autori valutano l'applicabilita' di tale procedura nell'eta' pediatrica alla luce delle propria esperienza.

1999-04-01

402

A clinician's guide to surgical fires. How they occur, how to prevent them, how to put them out.  

Science.gov (United States)

Surgical fires--fires that occur on or in a surgical patient--are a rare but devastating complication of surgical procedures. They can happen during almost any kind of operation and can have dire consequences for both the patient and the hospital. The risk of surgical fires can be minimized as long as everyone on the surgical team understands how fires start and what to do when they occur. It's important to recognize the interaction among ignition sources, oxidizers, and fuels--the three sides of the classic fire triangle. What's more, staff members need to be alert to "hidden" fire risks, such as unsuspected oxygen-enriched atmospheres and less-than-obvious fuels. They also need to be drilled in the correct steps for responding to fires. In this guide, we describe the elements of surgical fires, including the types of equipment and materials that make up each side of the fire triangle. Through a series of case histories, we illustrate the many ways in which fires ...

2003-01-01

403

Turbulence Investigation and Reproduction for Assisting Downstream Migrating Juvenile Salmonids, Part II of II; Effects of Induced Turbulence on Behavior of Juvenile Salmon, 2001-2005 Final Report.  

Energy Technology Data Exchange (ETDEWEB)

Passage through dams is a major source of mortality of anadromous juvenile salmonids because some populations must negotiate up to eight dams in Columbia and Snake rivers. Dams cause direct mortality when fish pass through turbines, but dams may also cause indirect mortality by altering migration conditions in rivers. Forebays immediately upstream of dams have decreased the water velocity of rivers and may contribute substantially to the total migration delay of juvenile salmonids. Recently, Coutant (2001a) suggested that in addition to low water velocities, lack of natural turbulence may contribute to migration delay by causing fish to lose directional cues. Coutant (2001a) further hypothesized that restoring turbulence in dam forebays may reduce migration delay by providing directional cues that allow fish to find passage routes more quickly (Coutant 2001a). Although field experiments have yielded proof of the concept of using induced turbulence to guide fish to ...

2005-07-01

404

Thermal-receiver designs for line-focus solar collectors  

Energy Technology Data Exchange (ETDEWEB)

Considerable potential exists for increasing the annual efficiency of line-focus collectors by reducing receiver heat losses. Five alternate receiver designs are compared with a standard design. The comparison is based on annual collector-field efficiency using optimized receiver designs. Of the receivers studied, the all-glass design and the cavity design provide the greatest increases in efficiency. Average fluid temperatures range from 200/sup 0/ to 450/sup 0/C. As a guide for further study, areas of uncertainty and potential problems are identified.

1982-02-01

405

Theoretical approach on microscopic bases of stochastic functional self-organization: quantitative measures of the organizational degree of the environment  

International Nuclear Information System (INIS)

There has been increased theoretical and experimental research interest in autonomous mobile robots exhibiting cooperative behaviour. This paper provides consistent quantitative measures of organizational degree of a two-dimensional environment. We proved, by the way of numerical simulations, that the theoretically derived values of the feature are reliable measures of aggregation degree. The slope of the feature's dependence on memory radius leads to an optimization criterion for stochastic functional self-organization. We also described the intellectual heritages that have guided our research, as well as possible future developments. (author)

2001-11-30

406

The neural basis of visual behaviors in the larval zebrafish  

British Library Electronic Table of Contents (United Kingdom)

We review visually guided behaviors in larval zebrafish and summarise what is known about the neural processing that results in these behaviors, paying particular attention to the progress made in the last 2 years. Using the examples of the optokinetic reflex, the optomotor response, prey tracking and the visual startle response, we illustrate how the larval zebrafish presents us with a very promising model vertebrate system that allows neurocientists to integrate functional and behavioral studies and from which we can expect illuminating insights in the near future.

2009-01-01

407

Surveillance and control. A new edition of the BETCGB guidebook for the control of dams in exploitation; Surveillance et controle. Une nouvelle edition du guide du BETCGB pour le controle des barrages en exploitation  

Energy Technology Data Exchange (ETDEWEB)

The French office for technical studies and control of big dams (BETCGB), has recently reedited the `guidebook for the control of dams in exploitation`. The aim of this document is to provide to the regional directions of industry, research and environment (DRIRE) a methodological help for their control actions of hydroelectric dams granted for exploitation. It comprises 6 chapters dealing with: the different type of dams, the inspection, the surveillance, the floods evacuation, the flood instructions, and the particular emergency plans. (J.S.)

1998-12-31

408

Study on high-resolution sequence stratigraphy framework of uranium-hosting rock series in Qianjiadian sag  

International Nuclear Information System (INIS)

The ore-hosting Yaojia Formation is composed of a set of braided stream medium-fine grained sediments. Guided by the basic theory of high-resolution sequence stratigraphy, and based on the core observation, the analysis of chemical composition of rocks, and data of natural potential logging and apparent resistivity logging, the authors have set up the high-resolution sequence stratigraphy framework of the ore-hosting Yaojia Formation, and discussed the relation of the stratigraphic structure of the middle cycle, as well as the paleotopography, the micro-facies to the formation of uranium deposit. (authors)

2005-07-01

409

Renewable energy systems for rural areas  

International Nuclear Information System (INIS)

In the rural areas, especially those located far enough from infrastructure facilities (highways and national roads, electricity and gas networks, etc.), energy supply (both quantitatively and qualitatively) is scarcer than in the urban ones. The purpose of this paper is to analyse the use of renewable energy hybrid systems in order to increase the quality and the quantity of energy supplied to the rural settlements. The paper is thus a guide of how to choose the appropriate energy source with higher potential and efficiency, minimal capital and operational costs and better comfort. (authors)

2007-11-22

410

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

411

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

412

Radiation hardening of semiconductor parts  

International Nuclear Information System (INIS)

This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.

413

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

414

Packaging Review Guide for Reviewing Safety Analysis Reports for Packagings  

Energy Technology Data Exchange (ETDEWEB)

This Packaging Review Guide (PRG) provides guidance for Department of Energy (DOE) review and approval of packagings to transport fissile and Type B quantities of radioactive material. It fulfills, in part, the requirements of DOE Order 460.1B for the Headquarters Certifying Official to establish standards and to provide guidance for the preparation of Safety Analysis Reports for Packagings (SARPs). This PRG is intended for use by the Headquarters Certifying Official and his or her review staff, DOE Secretarial offices, operations/field offices, and applicants for DOE packaging approval. This PRG is generally organized at the section level in a format similar to that recommended in Regulatory Guide 7.9 (RG 7.9). One notable exception is the addition of Section 9 (Quality Assurance), which is not included as a separate chapter in RG 7.9. Within each section, this PRG addresses the technical and regulatory bases for the review, the manner in ...

2007-04-12

415

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

416

NAME=\\  

Wastenet

...The RSPB: Birds by family: Owls E-mail to a friendE-newsletterContact us Home England Northern Ireland Scotland Wales About Overview Awards & recognition Contact ...Birds by family PrintHome Birds and wildlife Bird guide Birds by family Owls Owls Owls are specialised birds with round heads and rather flat ...or dished faces, with forward-facing eyes and a short, hooked bill. Most are nocturnal or crepuscular (active at dawn and dusk)... Owls are found all over the temperate and tropical parts of the world. Barn owl With heart shaped face, buff back ...

417

Modeling of instabilities induced by cage clearances in ball bearings  

Energy Technology Data Exchange (ETDEWEB)

Generalized dynamic motion of balls and cage in a ball bearing are simulated by solving the differential equations of motion under prescribed operating conditions and bearing geometry. The general cage motion is parametrically evaluated as a function of clearances both in the ball pockets and at the guide lands. The design significance of the modeling approach is demonstrated by the prediction of critical clearances which trigger certain instabilities in the cage motion. In more practical terms, the correlation between cage clearances and instability defines a wear life for the bearing under the prescribed operating conditions. 10 refs.

1991-01-01

418

Mode theory of the plasma cladding waveguide  

International Nuclear Information System (INIS)

The plasma cladding waveguide, which is a cylindrical dielectric core surrounded by a plasma cladding, is developed, and the guided modes and their characteristics of this waveguide are displayed through the present detailed theoretical research. The conditions of the single mode existing in the plasma cladding waveguide have been given, and the defined forbidden gap of frequency is discussed. It is found that the usage characteristics of the plasma cladding waveguide vary strongly with plasma frequency, and changing the plasma parameters can control the propagation mode. This paper focuses on exhibiting the basic characteristics and the potential applications of this new type of waveguide.

2007-04-07

419

Method to generate the first design of the reload pattern to be used with the Presto-B code in the simulation of the CNLV U-1 reactor; Metodo para generar el primer diseno del patron de recarga a ser utilizado con el codigo Presto-B, en la simulacion del reactor de la CNLV U-1  

Energy Technology Data Exchange (ETDEWEB)

This guide is applied for the reload pattern's formation for mirror symmetry of a core room and in accordance with the Control Cell core technique (of the english Control Cell Core - CCC) for the PRESTO-B code. (Author)

1992-08-15

420

International Water Power and Dam Construction Handbook 1993  

Energy Technology Data Exchange (ETDEWEB)

In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)

1993-01-01

421

Intelligent Interaction with Knowledge Associates  

Energy Technology Data Exchange (ETDEWEB)

The Knowledge Associates for Novel Intelligence (KANI) system provides a collection of automated 'associates' to actively support and participate in the information analysis task. In this paper, we describe the Information Integration Associate (IIA), which facilitates analyst interaction with underlying KANI reasoning and extraction associates and provides an interactive representation of the analytic process. We focus on features of the IIA that guide communication between the user and the KANI system in a way that ensures mutual understanding of the analytic task being performed, the capabilities of the system to assist the user, and the status of any reasoning and extraction conducted on behalf of the user by the KANI system.

2006-01-29

422

Guidelines on the medical therapy of persons accidentally overexposed to ionizing radiations. External contamination  

International Nuclear Information System (INIS)

The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)

423

Flue gas desulfurization information system (FGDIS) data base user's manual  

Science.gov (United States)

This manual is intended to provide a guide to the use of the Flue Gas Desulfurization Information System (FGDIS) data base which is a collection of data files consisting of information pertaining to the design and performance of flue gas desulfurization (FGD) systems. The files are stored at the U.S. Environmental Protection Agency National Computer Center (NCC), Research Triangle Park, NC. Access to these files and manipulation of the data therein is accomplished via System 2000, general data base management system developed by INTEL Corp. and supported by the NCC Univac 1100 hardware.

1981-03-01

424

Explosives synthesis at Los Alamos  

Energy Technology Data Exchange (ETDEWEB)

During the past two decades, the explosives synthetic effort at Los Alamos has been directed toward energetic heterocylic compounds and has produced some useful thermally stable explosives. The recent evolution of crystal-density predictive methods is guiding our current efforts toward ultrahigh performance explosives. Much of our effort is now on the development of new methods for preparing unique nitro compounds that are inaccessible by conventional techniques. This paper reviews the Los Alamos synthetic program with emphasis on the development of novel thermally stable explosives, and current efforts to synthesize high-density/performance explosives will be discussed.

1986-03-01

425

Experimental Uncertainty for the Thermal Expansion of a Simulated Fuel  

Energy Technology Data Exchange (ETDEWEB)

Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.

2006-07-01

426

Excel Hacks 100 Industrial Strength Tips and Tools  

CERN Document Server

The tips and tools in Excel Hacks include little known backdoor" adjustments for everything from reducing workbook and worksheet frustration to hacking built-in features such as pivot tables, charts, formulas and functions, and even the macro language. This resourceful, roll-up-your-sleeves guide shows you new ways to make Excel do things--from data analysis to worksheet management to import/export--that you never thought possible. Excel Hacks increases productivity with Excel and gives you hours of "hacking" enjoyment along the way. "

2009-01-01

427

Energy directory. Annual 1983. [References to 9800 individuals and organizations involved in energy policy  

Energy Technology Data Exchange (ETDEWEB)

A complete guide to 7000 key decision makers and 2800 organizations actively involved in energy today, the 1983 Directory updates the changes in state and Congressional energy offices that resulted from the 1982 elections, the reshuffling at DOE, the shifts of jurisdiction at the Department of the Interior, and the increasing role of the private sector in funding energy research and development. New features include the addition of nearly 100 major venture-capital firms and key public-affairs contacts. The Directory also features an Annual Energy Review highlighting development that will have international effects in the coming year.

1983-01-01

428

Educational research in Mainland China: current situation and developmental trends  

British Library Electronic Table of Contents (United Kingdom)

The influence of Confucian culture in Chinese Mainland China is reflected in the current situation and contextual trends of educational research content of educational thought of Confucianism, educational issues grounded on theoretical views of Confucianism, and the influence of the inclusiveness of Confucianism. In terms of research method, the current situation of educational research is reflected in empirical research whose methods value the construction of the metaphysical theoretical system, the guiding role of educational theories for educational reform practice, and research that enriches the literature. In terms of research value, the current situation of educational research is reflected in studies that focus on human nature, human relations, thoughts, willpower, emotion, human ri...

2011-01-01

429

Documentation of a model action plan to deter illicit nuclear trafficking  

International Nuclear Information System (INIS)

Theft, illegal possession, smuggling, or attempted unauthorized sale of nuclear and radiological materials remains a worldwide problem. The Nuclear Smuggling International Technical Working Group (ITWG) has adopted a model action plan to guide investigation of these cases through a systematic approach to nuclear forensics. The model action plan was recently documented and provides recommendations concerning incident response, collection of evidence in conformance with required legal standards, laboratory sampling and distribution of samples, radioactive materials analysis, including categorization and characterization of samples, forensics analysis of conventional evidence, and case development including interpretation of forensic signatures. (author)

2008-05-01

430

Development of three-dimensional aiming point guidance law  

British Library Electronic Table of Contents (United Kingdom)

A new aiming point guidance (APG) law in 3-dimensional space is derived analytically. The guidance law is capable of guiding the missile (interceptor) to a straight collision course with respect to the target. The missile turning rate command proportional to the error angle between the current missile heading and the predicted aim point is calculated based on the predicted target position. Performance of the APG law is numerically evaluated and compared with the proportional navigation guidance (PNG) law. The result of numerical simulation shows that the APG law is superior to the PNG law in terms of miss distance, time of interception and final stage missile turning rate demand.

2010-01-01

431

Comparison of Atmospheric Dispersion Models Between PHWR and PWR  

International Nuclear Information System (INIS)

The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences

2010-10-01

432

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

433

Clean air status report. Statistical analysis of pollution, 1966 through 1982  

Energy Technology Data Exchange (ETDEWEB)

Air pollution abatement measures are being intensified at the moment: Power plants and district heating systems are being retrofitted with high-efficiency desulphurisation and NO/sub 2/ reduction systems, the 3rd amendment of the Clean Air Technical Guide sets more rigid emission limits, and unleaded petrol and catalysts will significantly reduce car exhaust emissions. The author presents pollutant balances from 1966 to 1982 to contradict the popular notion that pollutant emitters formerly failed to take preventive measures.

1986-04-01

434

Bringing robotics technology down to Earth  

International Nuclear Information System (INIS)

Robotics technology is successfully being transitioned from space to terrestrial applications. It is being modified and enhanced to help in the US DOE's Environmental Restoration and Waste Management Program. Some examples of these applications, ranging from large multijointed manipulators to autonomously navigated remote vehicles, are outlined in this article. They include the following: underground storage tank technology demonstration; light-duty utility arm system; remotely controlled material-handling system; remotely operated excavator; self-guided transfer vehicle. 10 figs.

435

Beginning Scala  

CERN Document Server

The open source Scala language is a Java--based dynamic scripting, functional programming language. Moreover, this highly scalable scripting language lends itself well to building Cloud--based/deliverable Software as a Service (SaaS) online applications. Written by Lift Scala web framework founder and lead Dave Pollak, Beginning Scala takes a down--to--earth approach to teaching Scala that leads you through simple examples that can be combined to build complex, scalable systems and applications. This book introduces you to the Scala programming language and then guides you through Scala constr

2009-01-01

436

Aspiration cover for the loading site of a belt conveyer  

Energy Technology Data Exchange (ETDEWEB)

An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.

1982-01-01

437

Antimicrobial potential of Glycyrrhiza glabra roots  

British Library Electronic Table of Contents (United Kingdom)

The present study was aimed to investigate antimicrobial potential of Glycyrrhiza glabra roots. Antimycobacterial activity of Glycyrrhiza glabra was found at 500mg/mL concentration. Bioactivity guided phytochemical analysis identified glabridin as potentially active against both Mycobacterium tuberculosis H37Ra and H37Rv strains at 29.16mg/mL concentration. It exhibited antimicrobial activity against both Gram-positive and Gram-negative bacteria. Our results indicate potential use of licorice as antitubercular agent through systemic experiments and sophisticated anti-TB assay.

2008-01-01

438

Annual Report 2007. Nuclear Regulatory Authority  

International Nuclear Information System (INIS)

The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.

2004-07-11

439

An advanced NDA workstation for integrated safeguards  

International Nuclear Information System (INIS)

In this paper the authors describe the design and development of an advanced NDA workstation, which fits into an integrated data evaluation scheme for safeguards. This kind of instrument must be sort of an intelligent assistant to the inspection procedure, be able to generate as correct as possible measurements, guide the inspector throughout the procedure, and report descriptive data to the data evaluation system. The problem of improving the quality of the measurement is tackled using a simple expert system, which should convey in the instrument some of the physicist knowledge. The authors describe the hardware and software resources which were included in their design to reach the intended goal. A prototype of the machine has been built, and a preliminary software for Plutonium Isotopic Composition is under development.

1986-06-22

440

Usefulness of fluoroscopy-guided intra-articular injection of the knee  

Energy Technology Data Exchange (ETDEWEB)

To determine the accuracy of the intra-articular location of hyaluronic acid injection using a blind approach and to establish the usefulness of fluoroscopy-guided intra-articular injection. A fluoroscopy unit was used for 368 intra-articular injections of hyaluronic acid to 93 knees in 65 patients. Initially, blind needle positioning was conducted on the fluoroscopy table. The failure rate of the blind approach among the 368 injections was evaluated, and a relationship between the Kellgren-Lawrence grade (K-L grade) and the incidence of repeated failures using the blind approach was determined for injections to 52 knees in 37 patients who received a complete cycle of injections (five consecutive injections with a one-week interval between injections). Using a blind approach, 298 of 368 trials (81.2%) resulted in a needle tip being placed in an intra-articular location, while 70 of 368 trials resulted in an extra-articular placement of the needle tip. Among 52 ...

2007-06-15

441

STOMP, Subsurface Transport Over Multiple Phases, theory guide  

Energy Technology Data Exchange (ETDEWEB)

This guide describes the simulator`s governing equations, constitutive functions and numerical solution algorithms of the STOMP (Subsurface Transport Over Multiple Phases) simulator, a scientific tool for analyzing multiple phase subsurface flow and transport. The STOMP simulator`s fundamental purpose is to produce numerical predictions of thermal and hydrologic flow and transport phenomena in variably saturated subsurface environments, which are contaminated with volatile or nonvolatile organic compounds. Auxiliary applications include numerical predictions of solute transport processes including radioactive chain decay processes. In writing these guides for the STOMP simulator, the authors have assumed that the reader comprehends concepts and theories associated with multiple-phase hydrology, heat transfer, thermodynamics, radioactive chain decay, and nonhysteretic relative permeability, saturation-capillary pressure constitutive functions. ...

1996-10-01

442

SILMUSCEN and CLIGEN User`s Guide  

Energy Technology Data Exchange (ETDEWEB)

This User`s Guide has been prepared to provide recommendations for the selection and application of climatic scenarios in the Finnish Research Programme on Climate Change (SILMU). These scenarios are required for conducting impact studies in SILMU. They should reflect the current range of estimates of future climate in the Finnish region. In addition, they should be consistent with other projections of importance in impact studies, such as future atmospheric composition and sea level. Section 2 provides some background information about the types of scenarios required in SILMU and Section 3 offers a general description of the scenarios. In Section 4 there is some advice on applying sensitivity studies to complement the use of scenarios. Section 5 explains the installation of the SILMUSCEN program and Section 6 guides the user through some examples to illustrate how SILMUSCEN can be used. Section 7 offers some recommendations on which scenarios ...

1995-12-31

443

Results of 1995 characterization of Gunite and Associated Tanks at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This technical memorandum (TM) documents the 1995 characterization of eight underground radioactive waste tanks at Oak Ridge National Laboratory (ORNL). These tanks belong to the Gunite and Associated Tanks (GAAT) operable unit, and the characterization is part of the ongoing GAAT remedial investigation/feasibility study (RI/FS) process. This TM reports both field observations and analytical results; analytical results are also available from the Oak Ridge Environmental Information System (OREIS) data base under the project name GAAT (PROJ-NAME = GAAT). This characterization effort (Phase II) was a follow-up to the {open_quotes}Phase I{close_quotes} sampling campaign reported in Results of Fall 1994 Sampling of Gunite and Associated Tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee, ORNL/ER/Sub/87-99053/74, June 1995. The information contained here should be used in conjunction with that in the previous TM. The sampling plan is documented in ORNL Inactive Waste Tanks ...

1996-02-01

444

Computerized Tomography-guided fine-needle biopsy of peripheral pulmonary nodules < 2 cm in diameter  

International Nuclear Information System (INIS)

The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were pneumothorax in 80 ...

445

A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall  

Energy Technology Data Exchange (ETDEWEB)

Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to ...

2010-10-15

446

Vector Velocity Imaging Using Cross-Correlation and Virtual Sources  

DEFF Research Database (Denmark)

Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, measurements have ...

2006-01-01

447

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...

448

The value of high-resolution MR-imaging for the staging of malignant lesions of tongue, pharynx and larynx; Klinische Wertigkeit der hochaufloesenden Magnetresonanztomographie beim Staging von Tumoren der Mundhoehle, des Pharynx und des Larynx  

Energy Technology Data Exchange (ETDEWEB)

In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert auf die Bestimmung ...

1994-02-01

449

The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...

2011-04-15

450

Technetium-99m DISIDA hepatobiliary agent in diagnosis of hepatocellular carcinoma: relationship between detectability and tumor differentiation  

Energy Technology Data Exchange (ETDEWEB)

The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did not differ from that observed by 99mTc-sulfur colloid scan or ...

1988-12-01

451

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...

2004-07-01

452

Pioglitazone does not affect vascular or inflammatory responses after endotoxemia in humans.  

Science.gov (United States)

PPARgamma agonists have been proposed to exert more than metabolic benefits, particularly by anti-inflammatory mechanisms. We hypothesized that pioglitazone might modulate inflammatory and vascular responses to lipopolysaccharide (LPS). In a placebo-controlled parallel-group study in 18 healthy male subjects, the E. coli endotoxin model of inflammation (20 IU/kg i. v.) was employed to test the effect of 60 mg pioglitazone over nine days on inflammatory cytokines. Macrovascular function and microvascular blood flow were assessed by brachial artery ultrasound and retinal blood flow parameters, respectively. Pioglitazone increased brachial artery diameter by 5.6% but had no effect on other outcome parameters under resting conditions. LPS increased cytokine levels to peak concentrations of 91.3+/-22.5 ng/ml (IL-6), 261.4+/-60.0 ng/ml (TNFalpha), and 524.5+/-15.3 ng/ml (VCAM-1). The endotoxin caused microvascular vasodilation and increased retinal white blood cell flux, ...

2008-05-21

453

Longitudinal changes in extended roles in radiography  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this ...

2002-11-01

454

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen ...

2008-09-15

455

Clinical Significance of Renal Pelvic Dilatation less than 10 mm in Neonates: Correlation with Urinary Tract Infection and Vesicoureteral Reflux  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the correlation of mild renal pelvic dilatation (RPD) that is observed to be less than 10 mm on ultrasound (US) with urinary tract infection (UTI) and vesicoureteral reflux (VUR) in neonates. We reviewed 137 kidneys of 107 neonates who had RPD less than 10 mm on US. All the kidneys were divided into two groups: Group I (RPD <= 5.0 mm) and Group II (RPD > 5.0 mm), and we statistically analyzed the RPD change according to UTI and VUR. Seven neonates had VUR (5.1%), and there was no statistical significance between Group I (6 neonates, 5.6%) and Group II (1 neonate, 3.3%). Thirty seven cases (27%) had UTI and there was no statistical significance between Group I (30 cases, 28.0%) and Group II (7 cases, 23.3%). The RPD did not change in 81.8% of the cases, it increased in 4.4% of the cases and it decreased in 13.9% of the cases on follow up US. The incidence of VUR and UTI were not different according to the change of RPD. There were ...

2009-12-15

456

Accuracy of single versus combined use of ultrasonography or computed tomography in the localization of parathyroid adenoma  

International Nuclear Information System (INIS)

Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...

457

Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent  

Energy Technology Data Exchange (ETDEWEB)

We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate ...

2007-10-15

458

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear relationship exists between ...

1985-06-02

459

Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible ...

2007-08-15

460

Prospective benefit and effect of lipiodol marking in hepatocellular carcinoma; Moeglicher Nutzen und Auswirkung einer Lipiodolmarkierung auf die Histologie beim hepatozellulaeren Karzinom  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the benefit and the effect of intraarterial lipiodol application on histological analysis of patients suspected of having HCC. To determine whether lipiodol marking leads to a better biopsy result and how lipiodol or a transarterial chemoembolization influences the histological diagnosis. Materials and Methods: Two groups of patients were examined. Group A included 14 patients highly suspected of having an HCC which had previously been unsuccessfully biopsied. A transarterial embolization with lipiodol was performed in these patients to mark intrahepatic tumors which could not otherwise be defined in unenhanced CT. A biopsy was then repeated. Group B included 22 patients undergoing therapy using transarterial chemoembolization (TACE). A biopsy was performed to support the diagnosis of a multifocal HCC before changing the therapy. Results: The transversal diameters of the biopsied tumors were similar in both groups (A: 22 mm; B: 21 mm). The length of ...

2005-10-01

461

Optimizing the Protocol for Pulmonary Cryoablation: A Comparison of a Dual- and Triple-Freeze Protocol  

International Nuclear Information System (INIS)

The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not significantly different ...

2010-12-01

462

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo differenti procedure ablative percutanee  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...

1999-12-01

463

Evaluation of a novel radiopacifiying agent on the physical properties of surgical spineplex.  

Science.gov (United States)

Polymethlylmethacrylate (PMMA) is the most frequently used cement for percutaneous vertebroplasty and kyphoplasty. To aid visualisation during surgery cements are doped with radiopacifying agents such as Barium sulphate (Ba(2)SO(4)) or Zirconium Dioxide (ZiO(2)). Mounting research suggests that these agents may impair the biocompatibility of the cements. However, incorporating an alternative radiopacifier agent with excellent biocompatibility would be a significant step forward. Bioactive radiopaque glasses incorporating elements such as strontium (Sr) and zinc (Zn), known to have beneficial and therapeutic effects on bone, are of great interest in this respect. In this study, the Ba(2)SO(4) of the commercially available Spineplex was incrementally replaced with a radiopaque therapeutic glass composition. The resulting effects on cement setting time, peak isotherm, ultimate compressive strength, Young's modulus (up to 30 days cement maturation) and radiopacity were ...

2009-08-18

464

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv administration of Gd-DTPA. ...

2002-05-01

465

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

466

Guide to Combined Heat and Power Systems for Boiler Owners and Operators  

Energy Technology Data Exchange (ETDEWEB)

Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that only produce steam or hot water for process applications. By using fuel energy for both ...

2004-08-19

467

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...

1998-03-01

468

What factors influence the prevalence and accuracy of nursing diagnoses documentation in clinical practice? A systematic literature review  

British Library Electronic Table of Contents (United Kingdom)

Aim.- To identify what determinants influence the prevalence and accuracy of nursing diagnosis documentation in clinical practice. Background.- Nursing diagnoses guide and direct nursing care. They are the foundation for goal setting and provide the basis for interventions. The literature mentions several factors that influences nurses- documentation of diagnoses, such as a nurse-s level of education, patient-s condition and the ward environment. Design.- Systematic review. Method.- MEDLINE and CINAHL databases were searched using the following headings and keywords: nursing diagnosis, nursing documentation, hospitals, influence, utilisation, quality, implementation and accuracy. The search was limited to articles published between 1995-October 2009. Studies were only selected if they were...

2011-01-01

469

Supply chain networks and service-dominant logic: suggestions for future research  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The service-dominant (S-D) logic views supply chains as value co-creation networks. These networks promote knowledge growth amongst network members via resource deployment and coordination. The exchange of knowledge and utilization of operant resources among the network members leads to co-created service offerings and value proposals for the end-users, with the ultimate goal of transforming end-user experiences to perceptions of superior value-in-use. The purpose of this paper is to develop an illustration of the value co-creation concept and use this illustration as guide to examine the research gaps that are yet to be tapped in the area where supply chain networks and S-D logic intersects. Design/methodology/approach - The literature on S-D logic is reviewed and research gaps ...

2011-01-01

470

Summary of Information Presented at an NRC-Sponsored Low-Power Shutdown Public Workshop, April 27, 1999, Rockville, Maryland  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes a public workshop that was held on April 27, 1999, in Rockville, Maryland. The workshop was conducted as part of the US Nuclear Regulatory Commission's (NRC) efforts to further develop its understanding of the risks associated with low power and shutdown operations at US nuclear power plants. A sufficient understanding of such risks is required to support decision-making for risk-informed regulation, in particular Regulatory Guide 1.174, and the development of a consensus standard. During the workshop the NRC staff discussed and requested feedback from the public (including representatives of the nuclear industry, state governments, consultants, private industry, and the media) on the risk associated with low-power and shutdown operations.

1999-07-01

471

Seismic qualification method of equipment for nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Safety related equipment installed in Korean Nuclear Power Plants are required to perform a safety function during and after a seismic event. To accomplish this safety function, they must be seismically qualified in accordance with the intent and requirements of the USNRC Reg. Guide 1.100 Rev. 02 and IEEE Std. 344-1987. This paper defines and summarizes acceptable criteria and procedures, based on the Korean experience, for seismic qualification of purchased equipment to be installed in a nuclear power plant. As such the paper is intended to be a concise reference by equipment designers, architectural engineering company and plant owners in uniform implementation of commitments to nuclear regulatory agencies such as the USNRC or Korea Institute of Nuclear Safety (KINS) relating to adequacy of seismic Category 1 equipment. Thus, the paper provides the methodologies which can be used for qualifying equipment for safely related service in Nuclear Power Plants in a ...

1995-12-31

472

Rotary drill bit with rotary cutter  

Energy Technology Data Exchange (ETDEWEB)

A rotary drill bit having a drill bit body and at least one trunnion projecting from the drill bit body and a rotary cutter supported on at least one radial roller bearing on the trunnion. The rolling elements of the bearing are guided on at least one axial end facing the drill bit body in an outer bearing race groove incorporated in the bore of the rotary cutter. The inner bearing race groove is formed on the trunnion for the rolling elements of the radial roller bearing. At least one filling opening is provided which extends through the drill bit body and trunnion and is essentially axially oriented having one terminal end adjacent the inner bearing race groove and at least one filler piece for sealing the opening.

1981-03-17

473

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

474

Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL  

Science.gov (United States)

Recently the author showed that the widely used simulation code TDA3D, even though a single frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, the author applies this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, he shows that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is substracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.

1998-08-01

475

Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL  

Energy Technology Data Exchange (ETDEWEB)

Recently, we showed (Yu, Phys. Rev. E 58 (1998) 4991) that the widely used simulation code TDA3D, even though a single-frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, we apply this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, we show that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is subtracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.

1999-06-01

476

Indexes to Nuclear Regulatory Commission issuances, July--December 1996. Volume 44, Index 2  

Energy Technology Data Exchange (ETDEWEB)

Digests and indexes for issuances of the Commission (CLI), the Atomic Safety and Licensing Board Panel (LBP), the Administrative Law Judges (ALJ), the Directors` Decisions (DD), and the Decision on Petitions for Rulemaking (DPRM) are presented in this document. These digests and indexes are intended to serve as a guide to the issuances. Information elements common to the cases heard and ruled upon are: case name (owner(s) of facility); full text reference (volume and pagination); issuance number; issues raised by apellants; legal citations (cases, regulations, and statutes); name of facility, docket number; subject matter of issues and/or rulings; type of hearing (operating license, operating license amendment, etc.); type of issuance (memorandum, order, decision, etc.).

1997-04-01

477

High-visibilty two-photon interference at a telecom wavelength using picosecond regime separated sources  

CERN Document Server

We report on a two-photon interference experiment in a quantum relay configuration using two picosecond regime PPLN waveguide based sources emitting paired photons at 1550 nm. The results show that the picosecond regime associated with a guided-wave scheme should have important repercussions for quantum relay implementations in real conditions, essential for improving both the working distance and the efficiency of quantum cryptography and networking systems. In contrast to already reported regimes, namely femtosecond and CW, it allows achieving a 99% net visibility two-photon interference while maintaining a high effective photon pair rate using only standard telecom components and detectors.

2009-01-01

478

Health risks arising from ionizing radiation and chemical pollutants  

International Nuclear Information System (INIS)

In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified in German antipollution legislation. (orig.) 891 HP/orig. 892 MKO.

1979-10-03

479

Good plant design and operation for onshore carbon capture installations and onshore pipelines. A recommended practice guidance document. 1st. ed.  

Energy Technology Data Exchange (ETDEWEB)

The document provides: An overview of CCS technology including what plant equipment is novel and what is currently in use within the CCS or other industries; An in depth guide to carbon dioxide to broaden the readers understanding of the material and its health and safety issues; Key design features of plant and pipelines for carbon dioxide service including experience gained from the industrial gases sector; and Key operational information for plant and pipelines for carbon dioxide service including experience gained from the industrial gases sector to ensure that your operating practices take into account the latest operational experiences from carbon dioxide plant. 45 figs., 18 tabs.

2010-09-15

480

Fourier duality as a quantization principle  

Energy Technology Data Exchange (ETDEWEB)

The Weyl-Wigner prescription for quantization on Euclidean phase spaces makes essential use of Fourier duality. The extension of this property to more general phase spaces requires the use of Kac algebras, which provide the necessary background for the implementation of Fourier duality on general locally groups. Kac algebras - and the duality they incorporate are consequently examined as candidates for a general quantization framework extending the usual formalism. Using as a test case the simplest non-trivial phase space, the half-plane, it is shown how the structures present in the complete-plane case must be modified. Traces, for example, must be replaced by their noncommutative generalizations - weights - and the correspondence embodied in the Weyl-Wigner formalism is no more complete. Provided the underlying algebraic structure is suitably adapted to each case, Fourier duality is shown to be indeed a very powerful guide to the quantization of general physical ...

1996-08-01

481

Farm Business Management. Volume I. Vocational Agriculture Education.  

Science.gov (United States)

This curriculum guide provides a basic core of instruction for the first year of a three-year adult program in farm business management. It contains 12 units of instruction. Each unit consists of seven basic components: performance objectives, teacher activities, information sheets (content essential for meeting the cognitive objectives), assignment sheets (application of knowledges that are prerequisites to skill development), supplements and transparency masters, tests, and test and assignment sheet answers. Depending on the specific objectives, supplements, transparency masters, assignment sheets, and job sheets may or may not be included. The 12 units cover orientation, recordkeeping, inventory and net worth statement, depreciation, enterprise accounting and supplemental records, enterprise budgets, cash-flow planning, farm credit, partial budgeting, marketing, income tax management, and year-end closing of records. (YLB)

1983-12-01

482

Dietary and Nutritional Treatments for Attention-Deficit/Hyperactivity Disorder: Current Research Support and Recommendations for Practitioners  

British Library Electronic Table of Contents (United Kingdom)

Evidence for dietary/nutritional treatments of attention-deficit/hyperactivity disorder (ADHD) varies widely, from double-blind, placebo-controlled trials to anecdotal. In guiding patients, clinicians can apply the SECS versus RUDE rule: treatments that are Safe, Easy, Cheap, and Sensible (SECS) require less evidence than those that are Risky, Unrealistic, Difficult, or Expensive (RUDE). Two nutritional treatments appear worth general consideration: Recommended Daily Allowance/Reference Daily Intake multivitamin/mineral supplements as a pediatric health intervention not specific to ADHD and essential fatty acids, especially a mix of eicosapentaenoic acid, docosahexaenoic acid, and ?-linolenic acid as an ADHD-specific intervention. Controlled studies support the elimination of artificial fo...

2011-01-01

483

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

484

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

485

Design and control of six degree-of-freedom active vibration isolation table.  

Science.gov (United States)

A six-axis active vibration isolation system (AVIS) is designed by using the direct driven guide and ball contact mechanisms in order to have no cross-coupling between actuators. The point contact configuration gives an advantage of having an easy assembly of eight voice coil actuators to an upper and a base plate. A voice coil actuator is used since it can provide a large displacement and sufficient bandwidth required for vibration control. The AVIS is controlled considering the effect of flexible vibration mode in the upper plate and velocity sensor dynamics. A loop shaping technique and phase margin condition are applied to design a vibration controller. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system. The scanning profiles of the specimen are compared together by using the atomic force microscope. The robustness of the AVIS is verified by showing the impulse response. ...

2010-03-01

486

Corrosion: Understanding the basics  

Energy Technology Data Exchange (ETDEWEB)

This new book presents a practical how to approach to understanding and solving the problems of corrosion of structural materials. Although it is written mainly for those having a limited technical background in corrosion, it also provides more experienced engineers with a useful overview of the principles of corrosion and can be used as a general guide for developing a corrosion-control program. Contents include: the effects and economic impact of corrosion; basic concepts important to corrosion; principles of aqueous corrosion; forms of corrosion: recognition and prevention; types of corrosive environments; corrosion characteristics of structural materials; corrosion control by proper design; corrosion control by materials selection; corrosion control by protective coatings and inhibitors; corrosion control by cathodic and anodic protection; corrosion testing and monitoring; techniques for diagnosis of corrosion failures; and glossary of corrosion-related terms.

2000-07-01

487

Contribution to 3D-operational geodesy. Pt. 3  

Energy Technology Data Exchange (ETDEWEB)

Whereas in part 1 and 2 the detailed observation equations of terrestrial type for an integrated geodetic model are presented this paper will outline how the theory is transferred in an operational program. The main lines of functions of the FORTRAN IV program are discussed. Since the input specifications as well as the data requirements are described in detail and illustrated by example of input and output part 3 can serve as an user-guide for OPERA. OPERA is an acronym for operational adjustment. Besides the integrated determination of 3D-geocentric coordinates and the gravity disturbing potential the program can handle all cases of traditional geodesy (in total 13 variants of solution are provided) equivalent also with adjustments in ellipsoidal coordinates B, L or H, as well as constrained adjustments, pure prediction of the gravity disturbing field, etc.

1983-01-01

488

Computer system for digitizing, analyzing and plotting well log data (a user's guide to WELLOG. Rev. 1)  

Energy Technology Data Exchange (ETDEWEB)

WELLOG is a system of programs developed at the Earth Science Laboratory to be used to digitize well logs and perform some analysis and plotting of the data. Multiple logs can be plotted side by side for correlation analysis and up to three logs can be plotted in a cross plot. Data entry and editing functions are also provided by the programs. This system of well log interpretation programs is presently operating on the University of Utah UNIVAC 1108 computer. Digitizing of well logs is accomplished by an old model CALMA (off-line) digitizer. Those parts of WELLOG that handle the digitized data tapes are extremely machine dependent. The parts of WELLOG that produce the plots and handle the data beyond the digitized data tape are more portable.

1980-03-01

489

Computer and Network Security in Small Libraries: A Guide for Planning.  

Science.gov (United States)

This manual is intended to provide a free resource on essential network security concepts for non-technical managers of small libraries. Managers of other small nonprofit or community organizations will also benefit from it. An introduction defines network security; outlines three goals of network security; discusses why a library should be concerned with network security; and describes limits of this work. The manual is divided into three main parts. Part One features the management issues related to network security: analyzing risk, developing a security plan and policy, the funding requirements libraries can expect in operating their networks, and implementing adequate security. Part Two describes the areas of computer networks that need to be secured, and provides a description of many of the security measures necessary for adequate security. Part Three presents sample documents that may be help in the library's efforts to secure its network A glossary and bibliography are also ...

2000-12-01

490

Brief guide to the MINC-method for modeling flow and transport in fractured media  

Science.gov (United States)

MINC stands for Multiple INteracting continua.'' It is an approximate method for modeling fluid and heat flow in fractured- porous media, developed by Pruess and Narasimhan (1982, 1985) at the Lawrence Berkeley Laboratory. The method is applicable to flow processes in which an important aspect is the exchange of fluid, heat, or chemical species between fractures and unfractured rock. Examples include production and injection operations in fractured geothermal reservoirs, water-flooding, steamflooding, and other methods for enhanced oil recovery from fractured reservoirs, as well as chemical transport and contaminant migration in fractured rock. MINC can only be applied to media in which the fractures are sufficiently well connected so that a continuum treatment of flow in the fracture network can be made.

1992-05-01

491

Biomass production and relative competitiveness of a C3 legume and a C4 grass co-dominant in the semiarid Loess Plateau of China  

British Library Electronic Table of Contents (United Kingdom)

Bothriochloa ischaemum L. and Lespedeza davurica (Laxm.) Schindl. are two co-dominant species of great importance in reducing soil and water loss and maintaining the distinctive natural scenery of the semiarid Loess Plateau of China. Our aim was to determine the growth and interspecific competition between these species under water stress to facilitate the prediction of community succession and guide the selection of appropriate methods of conservation and use in the area. A pot experiment was designed to investigate the effects of water stress and competition on biomass production and allocation, relative competitive ability and water use efficiency of the two species. Bothriochloa ischaemum (a C4 perennial herbaceous grass) was planted in the same pot with L. davurica (a C3 perennial leg...

2011-01-01

492

BRE: Consultation on the Green Guide update  

Wastenet

...Content 3a LCA Methodology - Characterisation(PDF) 3a1 BRE Response - Characterisation 3b LCA Methodology - Normalisation (PDF) 3b1 BRE Response - Normalisation 3c LCA Methodology - Weighting (PDF) 3c1 Feedback - Weighting 3c2 Weightings Exercise (PDF) 4 Specification (PDF) 4a - Functional Units Spreadsheet (Excel) 4b Specification List (Excel) 5 Energy Model (PDF) 6 Whole Life perfomance 6b Response Note To Briefing Note 6 - Whole Life Performance (PDF) 7 End-of-Life and Waste models (PDF) 7a Waste routes and rates feedback (PDF) 7b Waste Disposal Routes for Industry Consultation 7c Site Wastage Rates for Industry Consultation 8 Existing LCA ...

493

Architects and engineers guide to energy conservation in existing buildings  

Energy Technology Data Exchange (ETDEWEB)

The manual enhances and simplifies the work of those architects and engineers whose practice includes the analysis and modification of existing buildings to reduce both fuel consumption and operating costs. A review of the principles of energy use and conservation is given. The manual also provides a step-by-step methodology for assessing and improving the year-round energy performance of buildings, as well as a series of forms, charts, and nomographs designed to serve as day-to-day tools in the energy professional's toolbox. After a cost-benefit analysis is prepared for each conservation opportunity, the owner will be able to implement decisions based on projected energy savings and calculate investment costs, operational changes, and payback periods. Each of these considerations is accorded a detailed treatment.

1980-02-01

494

Approach to the homoerythrina alkaloids using a tandem N-alkylation/azomethine ylide cycloaddition.  

Science.gov (United States)

Synthetic efforts toward the homoerythrina alkaloids 1-3 are described. Two separate model systems guided the pivotal [3 + 2] azomethine ylide cycloaddition cascade to form the A-C rings of these alkaloids. The cycloaddition precursors 63 and 68, prepared in nine and ten steps, respectively, from alkyne 47, each contain an enolizable ketone, a tethered electrophile, and an electron-poor dipolarophile. Heating 63 and 68 with the stannyl amine 17 generated demethoxyschelhammeridine 65 and demethoxyschelhammericine 70, the products of intramolecular azomethine ylide cycloadditions. Subsequent attempts to install the C-3 methoxy group of 1-3 are also described. PMID:17465572

2007-04-28

495

A study of the Teachers` Academy for Mathematics and Science  

Energy Technology Data Exchange (ETDEWEB)

The Teachers` Academy for Mathematics and Science in Chicago (TAMS) is a freestanding institution founded in 1989 by scientists and a variety of other stakeholders, to advance the systemic reform of mathematics and science education in Chicago`s public schools. It focuses on the ``re-tooling`` of its elementary level teachers. The TAMS program, which has been funded in part by the DOE, contributes to strategic goals two through five of the Office of University and Science Education (OUSE). This evaluation of TAMS by the National Center for Improving Science Education is primarily a qualitative study that summarizes the history and current status of the organization and its programs. Data was obtained through extensive interviews, observations, and document review, using a framework of templates to guide data collection and analyses. The findings are organized around a series of lessons learned from the first three years of TAMS and conclusions about its current ...

1994-09-15

496

A six-axes robot for deep water applications  

Energy Technology Data Exchange (ETDEWEB)

The six-axes industrial robot MANUTEC r15 UW was modified to work underwater and successfully tested down to the simulated water depth of 1100 m. Next step in the program was to use this robot as a handling tool for inspection tasks at the welding seam of an underwater structure conducted with CCD-cameras and distance sensors. This was also to demonstrate the possibility to assist and later on to replace divers from this work. Additional research was focussed on the stiffness and rigidity of the robot during the precise guiding of tools and workpieces under current water conditions up to a flow velocity of 1.1 m/s. Present work is concentrated on the application of this subsea robot on a maintenance task at the Brazilian underwater template OCTOS-1000. For this experiments the robot is integrated in a large mock-up which simulates a quarter section of this template. (orig.)

1994-01-01

497

A numerical investigation of scale-up effects on coke yields of a thermal cracking Riser reactor  

Energy Technology Data Exchange (ETDEWEB)

A validated computational fluid dynamics (CFD) computer code, ICRKFLO, was used to investigate the scale-up effects on the coke yields of thermal cracking riser factors. Comparisons were made for calculated coke yields of pilot- and commercial-scales riser units. Computational results show that the riser aspect ratio, reaction temperature, particle residence time, and particle/oil ratio have major impacts on the coke yield. A computational experiment was conducted to determine optimal operating conditions for a conceptual design of a commercial-scale riser unit. This experiment showed that the performance loss in scale-up from pilot to commercial scale may be almost completely recovered through optimizing the operating conditions after scale-up using the CFD simulations as a guide.

1995-05-01

498

1994 MWD comparison tables  

Energy Technology Data Exchange (ETDEWEB)

Twenty-eight measurement while drilling tools are listed in this year's MWD Comparison Tables. Updated data on tools listed last year and data on five new tools provide a convenient guide for choosing MWD systems. Future MWD technologies include sonic tools and tools that make measurements ahead of the bit. For the seventh year, Petroleum Engineer International presents the Measurement While Drilling (MWD) Tables comparing a variety of available tools from many different vendors. The 1994 Tables include two additional companies and five new MWD tools not found in last year's Tables. However, the tables should serve only as a reference source. System specifications can change rapidly as tools are refined and new technologies develop. Operators and contractors should consult designated MWD marketing representatives before making a final tool selection.

1994-05-01