Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against ...
Purpose:To provide a literature review of implant related complications from bilateral NewColorIris implantation (Kahn Medical Devices, Panama City, Panama).Methods:A...Full Text Available
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasounddevice (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good ...
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic ...
Air Force Prototype Thermal Flash Protective Device (TFPD) Goggles were furnished to USAFSAM by the Life Support System Program Office, Aeronautical Systems Division, for determination and evaluation of their eye-type goggles caused stressed areas. The bonding used in the production model eliminated the stressed areas, resulting in increased closed-state optical density, particularly in the upper nasal area of the lens.
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...
AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.
This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available
Laser safety standards and eye protection (filters) are designed to limit ocular exposures to prevent retinal lesions, yet eyesafe laser exposures can disrupt vision by causing glare and flashblindness. Protective filters can have opposing effects on vision function. They reduce laser exposures but also reduce task luminance and contrast. Filters alone may interfere with vision and consequently reduce work safety and performance. It is therefore important to be able to predict the effects of both laser exposures and protective filters to assess trade-offs between protection and visual function. This paper briefly reviews the methods, concepts, and experimental database used in our laboratory to predict laser, filter, and laser-plus-filter effects on tasks involving visual detection. The modeling approach uses estimates of the spatial distribution of light in the retinal image of the laser source to predict glare, flashblindness, and retinal lesions. It also ...
Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.
Abstract During the past few years, laparoscopy has become the gold standard for some surgical procedures and its applications continue to expand. Because of multiple factors such as loss of tactile perception, two-dimensional visualization of the three-dimensional surgical field, and demanding bimanual hand-eye coordination, special training is required to achieve proficiency with laparoscopy. In this study, as the first step toward evidence-based development of strategies to improve the quality of laparoscopy training from brain activity and behavior relationships, a laparoscopy training simulator was developed for use in functional MRI. Experiments confirmed the functional MRI compatibility of the device. Representative behavioral and functional MRI results for two subjects showed the f...
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design ...
The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the ...
The refractive error in 15 eyes with threshold retinopathy of prematurity treated with diode laser photocoagulation was compared with 25 eyes with the same disease severity treated by cryotherapy. Myopia...Full Text Available
The currently available methods for the diagnosis of dry eye are still far from being perfect for a variety of reasons. This review attempts to highlight the advantages and disadvantages of both traditional...Full Text Available
PurposeTo evaluate pathologic features of the photoreceptors in myopic foveoschisis with the Fourier-domain optical coherence tomography (FD-OCT).DesignObservational case series.MethodsSeventeen eyes of 15 patients with myopic foveoschisis (foveal detachment type, six eyes; foveoschisis type, 11 eyes) were included. We observed the photoreceptor inner and outer segments (IS/OS) and evaluated the morphologic status using FD-OCT. Fundus photographs and time-domain OCT (TD-OCT) images also were obtained.ResultsIS/OS defects, which are uncommon in retinal detachments in eyes with myopia, were seen clearly in five eyes (three eyes [50%] with the foveal detachment type; two eyes [18%] with the foveal schisis type). Fundus photographs showed myopic chorioretinal atrophy in eight study eyes (47%),...
Seventeen eyes of patients who were being followed by their ophthalmologists for aphakic (8 eyes) or pseudophakic (9 eyes) cystoid macular edema (CME) were examined on referral. All eyes showed retinal detachment (RD), and eight eyes had CME with RD. Most RDs were inferior and shallow. Proliferative vitreoretinopathy (PVR) was noted in 15 eyes (88.2%). There was history of vitreous loss during the last intraocular surgery in 88.2% eyes. Visual acuity ranged from 20/40 to hand movements. Fundus view was hazy in most eyes, and indirect ophthalmoscopy was most useful in detecting RD. Retinal reattachment with scleral buckling and/or vitrectomy was achieved in 16 eyes (94.1%). Postoperative visual recovery was jeopardized due to longstanding macular detachment of greater than 1 month in 11 ...
Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much ...
The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states ...
The bands may be classified as primary if they merge into the eyewall encircling the eye of the storm, or secondary if they are disconnected from the ...
We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle ?, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the eye with only the cornea, and these increased on average when the IOL geometry and position were included. Relevant individual aberrations were well predicted by the complete eye model. Corneal spherical aberration and horizontal coma were compensated by the IOL, and in 58.3% of the cases IOL tilt and decentration contributed to compensation of horizontal coma. We conclude that customized computer eye models are a good representation of real eyes with IOLs ...
The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available
We investigate a method for gene delivery to vascular smooth muscle cells using ultrasound triggered delivery of plasmid DNA from electrostatically coupled cationic microbubbles. Microbubbles...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available
To quantify the number of cases and clinical courses of Acanthamoeba keratitis treated at the King Khaled Eye Specialist Hospital (KKESH) between December 1982 and May 2005, and to review their clinical course and response to medical and surgical therapy. Retrospective review of medical records of all patients with Acanthamoeba keratitis diagnosed by the KKESH Microbiology or Pathology or Pathology Laboratory since the opening of the hospital. During a period of over 22 years, only six cases of confirmed. Acanthamoeba keratitis were diagnosedand treated at KKESH. In two cases the diagnosis was made by corneal biopsy, while four cases required examination of a histopathology specimen obtained at the time of therapeutic keratoplasty to establish the diagnosis. One eye was cured by medical therapy, while five eyes required one (4eyes) or two (1 eye) therapeutic penetrating keratoplasty ...
Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of ...
PURPOSE: The purpose of this qualitative study was to explore the causes and management of blindness and blinding eye conditions as perceived by rural dwellers of two Yoruba communities in Oyo State,...Full Text Available
Sixty glaucomatous eyes of 60 patients treated with laser trabeculoplasty as primary therapy were reviewed retrospectively. There were 42 eyes with capsular glaucoma and 18 with simple glaucoma. The...Full Text Available
A 37 year old male was referred to our centre for management of episcleritis with peripheral keratitis in the right eye. He had a history of ocular discomfort in the right eye of 1 week duration. Slitlamp...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
AIMS: To examine the frequency of intraocular metastases in patients who had died of cancer, in an eye bank and necropsy population sample. METHODS: The first group included 302 cancer cases received...Full Text Available
...Seeing-eye or guide dogs will remain in guiding...possible agitation of military police working dogs, seeing-eye or guide...allowed in or around working dog kennels and facilities...used for registering military personnel on...
Sep 19, 2011 ... (The whispering voice, on the other hand, was the latest in ultrasound directed audio technology from the firm Audio Spotlight.) The NASA ...
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning ...
As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur ...
Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.
Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available
BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available
... United States, there are 14 million people with diabetes and while most will not lose their vision ... good deal higher among people with Type I diabetes -- the type that usually begins in childhood and ...
We determined the underlying aetiology of blindness for the registered blind population of the Province of Newfoundland and Labrador. In both 1981 and 1984 single-gene disorders accounted for 30% of...Full Text Available
your eye to the SCN in your brain, so that light ... Owls are individuals who go to bed late, like to get up late in the moming. And the moming types, ...
The eye is an easily accessible, highly compartmentalised and immune-privileged organ that offers unique advantages as a gene therapy target. Significant advancements have been made in understanding...Full Text Available
Changing the direction of the line of sight is essential for the visual exploration of our environment. When the head does not move, re-orientation of the visual axis is accomplished with high...Full Text Available
Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...
The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
Larvae of the sunburst diving beetle, Thermonectus marmoratus, have a cluster of six stemmata (E1-6) and one eye patch on each side of the head. Each eye has two retinas: a...Full Text Available
Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus ...
Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available
BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Doppler ultrasound (TVCD) may predict those prognostic factors...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.
Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available
BackgroundLifestyle, genetics and environmental factors are established determinants of bone density. We aimed to describe the bone characteristics of competitive top-ranked Nigerian...Full Text Available
An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available
To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...
Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm ...
KMeyeDB () is a database of human gene mutations that cause eye diseases. We have substantially enriched the amount of data in the database, which now contains information about the mutations of 167 human genes causing eye-related diseases including retinitis pigmentosa, cone-rod dystrophy, night blindness, Oguchi disease, Stargardt disease, macular degeneration, Leber congenital amaurosis, corneal dystrophy, cataract, glaucoma, retinoblastoma, Bardet-Biedl syndrome, and Usher syndrome. KMeyeDB is operated using the database software MutationView, which deals with various characters of mutations, gene structure, protein functional domains, and polymerase chain reaction (PCR) primers, as well as clinical data for each case. Users can access the database using an ordinary Internet browser wi...
PurposeTo characterize the morphology of outer retinal holes caused by solar maculopathy, using spectral-domain optical coherence tomography (SD-OCT). DesignThis study is an observational case series. MethodsThe SD-OCT findings of 3 patients (6 eyes) with chronic solar maculopathy are presented. ResultsSD-OCT demonstrates a characteristic appearance of partial-thickness hole(s) in the outer retina at the fovea. In 3 of 6 eyes, there is 1 hole directly beneath the umbo. In the remaining 3 eyes, there are multifocal holes spread across the fovea. Holes in more restricted layers, as had been previously reported with time-domain OCT, were not seen. In addition, advanced visualization of SD-OCT data demonstrates a hyperreflective ring around the outer retinal hole. ConclusionsSD-OCT can be used...
Over the last decade, the use of the zebrafish as a genetic model has moved beyond the proof-of-concept for the analysis of vertebrate embryonic development to demonstrated utility as a mainstream...Full Text Available
Sensory rhodopsins (SRs) belong to a subfamily of heptahelical transmembrane proteins containing a retinal chromophore. These photoreceptors mediate the cascade of vision in animal eyes and phototaxis...Full Text Available
An ultrasmall spot size scanning laser ophthalmoscope has been developed that employs an annular aberration-corrected incident beam to increase the effective numerical aperture of the eye thereby reducing...Full Text Available
BackgroundDespite having the largest population in Africa, Nigeria has no accurate population based data to plan and evaluate eye care services. A national survey was undertaken...Full Text Available
It has been of interest whether and when the rearrangement of neuronal circuits can be induced after projection patterns are formed during development. Earlier studies using cats reported that the rearrangement...Full Text Available
Study objective:To describe sleep characteristics and rapid eye movement (REM) sleep behavior disorder in patients with Guadeloupean atypical parkinsonism (Gd-PSP), a tauopathy resembling...Full Text Available
How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available
PURPOSE: Visual loss following panretinal photocoagulation was found in the Diabetic Retinopathy and the Early Treatment Diabetic Retinopathy Studies. This study was designed to test the hypothesis...Full Text Available
We report the first case of human infection by Phaeoisaria clematidis. This fungus caused a corneal ulcer in a Brazilian man who had previously suffered an eye injury. Diagnosis was...Full Text Available
Purpose:Methicillin-resistant Staphylococcus aureus (MRSA) strains are commonly classified as hospital-acquired (HA) or community-acquired (CA). Typical HA-MRSA...Full Text Available
Oxidative stress occurs when the level of prooxidants exceeds the level of antioxidants in cells resulting in oxidation of cellular components and consequent loss of cellular function. Oxidative...Full Text Available
We performed a prospective study evaluating the 2-year success rate of extracapsular cataract surgery and posterior chamber IOL insertion performed in 610 eyes by an experienced surgeon in the Nepal...Full Text Available
The composition of the extracellular matrix (ECM) was examined in the developing lens and optic cup (stages 11-16) of the long-tailed monkey (Macaca fascicularis) using peroxidase immunocytochemistry....Full Text Available
Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits....Full Text Available
AbstractPurposeThe aim of this study was to elucidate the effects of the Rho-kinase inhibitor, H-1152, on cultured human trabecular meshwork (HTM) cells, TM morphology,...Full Text Available
OBJECTIVE: To evaluate the interobserver agreement of ultrasonographic assessment of finger and toe joints in patients with rheumatoid arthritis (RA) by 2 investigators with different medical backgrounds. METHODS: Ultrasonography and clinical examination were performed on 150 small joints of 30 patients with active RA. A General Electric LOGIQ 500 ultrasound unit with a 7-13-MHz linear array transducer was used. In each patient, 5 preselected small joints (second and third metacarpophalangeal, second proximal interphalangeal, first and second metatarsophalangeal) were examined independently on the same day by 2 ultrasound investigators (an experienced musculoskeletal radiologist and a rheumatologist with limited ultrasound training). Joint effusion, synovial thickening, bone erosions, and power Doppler signal were evaluated in accordance with an introduced 4-grade semiquantitative scoring system, on which the investigators ...
There is considerable interest in the use of silicon devices as qubits for quantum computing. The existence of nuclear spin in a silicon isotope and the complex band structure of silicon are unfavourable for this application of silicon devices. (viewpoint)
In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...
Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...
17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).
Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...
Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...
This paper addresses one source of degradation in OPV devices: the metal/organic interface. The basic approach was to study the completed device stability vs. the stability of the organic film itself as shown in subsequent devices fabricated from the films.
... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...
A monolithic micromachined waveguide device or devices with low-loss, high-power handling, and near-optical frequency ranges is set forth. The waveguide and integrated devices are capable of transmitting near-optical frequencies due to optical-quality sidewall roughness. The device or devices are fabricated in parallel, may be mass produced using a LIGA manufacturing process, and may include a passive component such as a diplexer and/or an active capping layer capable of particularized signal processing of the waveforms propagated by the waveguide.
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according...Full Text Available
Abstract. Purpose: To determine whether vitrectomy with 25-gauge instruments contributes to better postoperative visual recovery after macular hole (MH) surgery. Methods: The medical records for 46 consecutive eyes operated for MH by a single surgeon were retrospectively examined. Vitrectomy had been performed with a 25-gauge instrument in 23 eyes (25-G group) and with a 20-gauge instrument in 23 eyes (20-G group). Postoperative visual acuity (VA) in logMAR (logarithm of the minimum angle of resolution) units after 1 week and 1, 3, 6, 9 and 12 months, operating time, and volume of intraocular irrigating fluid were compared between the two groups. Results: Mean preoperative logMAR VA was 0.72 in the 25-G group and 0.68 in the 20-G group (p = 0.282, unpaired t-test). One week after surgery, ...
Financial DisclosurePhacoemulsification and implantation of a hydrophilic acrylic toric intraocular lens (IOL) (T-flex 623T) with customized cylindrical power was performed in 1 eye in 3 consecutive patients with cataract and high postkeratoplasty astigmatism (range 6.75 to 8.75 diopters [D]). Twelve months postoperatively, the uncorrected distance visual acuity improved from 20/200 to 20/30 in Case 1, from 20/400 to 20/40 in Case 2, and from 20/200 to 20/25 in Case 3 and the corrected distance visual acuity was 20/25 or better in all 3 eyes. The spheroequivalent was within +-0.50 D of the intended value and the refractive astigmatism was less than 1.00 D. The corneal grafts were transparent, and the endothelial cell loss range was 6% to 12%. Rotation of the toric IOL was less than 5 degre...
Abstract. The pathogenesis of normal (intraocular) pressure glaucoma has remained unclear so far. As hospital-based studies showed an association of normal-pressure glaucoma with low systemic blood pressure, particularly at night, and with vasospastic symptoms, it has been hypothesized that a vascular factor may play a primary role in the pathogenesis of normal-pressure glaucoma. That assumption may, however, be contradicted by the morphology of the optic nerve head. Eyes with normal-pressure glaucoma and glaucomatous eyes with high-intraocular pressure can show a strikingly similar appearance of the optic nerve head, including a loss of neuroretinal rim, a deepening of the optic cup, and an enlargement of parapapillary atrophy. These features, however, are not found in any (other) vascula...
Shallow-water zooplanktivorous fish rely on their vision for foraging. In shallow water, feeding efficiency decreases in dim light and thus the fish cease foraging at crepuscular hours. Creatures living in the lower parts of their depth ranges are expected to be exposed to limited light levels for longer hours. However, observations of the zooplanktivore Dascyllus marginatus showed little change in foraging duration down to 40m deep. We asked whether the visual system's functionality changes with depth along the depth range of this damselfish; we examined eye and retina anatomy for changes in visual acuity and light sensitivity and used the optomotor response to test for spatial and temporal light summation. We found only minor changes in the anatomy of the eye that are not expected to aff...
The authors describe an effect of suppression of invasion of the guinea pig eye conjunctiva and the HEp-2 epithelial cells by virulent Sh. flexneri bacilli, with a simultaneous administration of the same dose of avirulent shigella mutants, genetically connected with them. The data of morphological study and experiments with 3H-glucose labeled shigellae carried out on the cell species model indicated that the bacterial competition for the specific sites for absorption on the epithelial cells underlay the observed phenomenon. PMID:331774
The proton therapy gives an irradiation adapted to the shape and the depth of tumors ( eyes, head and neck) with a millimetric, even sub millimetric precision for the ophthalmological tumors. It is equally an excellent tool for the pediatrics tumors. For numerous treatments in France the proton therapy is associated to the photons treatments (x radiation). however, others physical treatments could modulate the medical offer, such thermal therapy or treatments by ultrasonic waves. (N.C.)
PurposeOptic nerve aplasia (ONA, OMIM 165550) is a very rare unilateral or bilateral condition that leads to blindness in the affected eye, and is usually associated with other ocular...Full Text Available
... Quenching is one of the most fundamentally complex processes in the heat treatment of metals, and it is something on which mechanical properties and distortion of engineering components depend. AU$236.36 ex-GST Terms and Conditions Eyes on the Skies: 400... Adopted as the official book of the International Year of Astronomy (IYA) 2009, this stunningly illustrated history of telescopic discovery spans the range ...
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
A critical element of a retinal prosthesis is the stimulating electrode array, which is placed in close proximity to the retina. It is via this retinal-electrode interface that a retinal prosthesis electrically stimulates nerve cells to produce the perception of light. The impedance load seen by the current driver consists of the tissue resistance and the complex electrode impedance. The results in this paper show that the tissue resistance of the retina is significantly greater than that of the vitreous humor in the eye. Circuit models of the electrode-retina interface are used to parameterize the different contributors to the overall impedance.
Citation information: Rosenfield M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic Physiol Opt 2011, 31, 502-515. doi: 10.1111/j.1475-1313.2011.00834.x ABSTRACT: Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor anomalies and dry eye. Accommodation and vergence responses to ...
An overview is given of techniques to analyze all kinds of complaints from occupants of office buildings about their working environment: headaches, lethargy, eye irritation, respiratory problems, and complaints about the temperature and draught. Special attention is paid to the sensory evaluation of air quality. 4 figs., 7 refs.
Purpose. To report a comparative prospective long-term functional analysis after Riboflavin UV A corneal cross-linking (CXL) in three different age groups of patients affected by progressive keratoconus (KC). Methods. Functional analysis comprised paediatric patients (?18 years) included 152 eyes (29.5%); intermediate group (19-26 years) 286 eyes (55.4%), and adults (?27 years) 78 eyes (15.1%). CXL was performed according to the Siena protocol by using the Vega CBM (Caporossi-Baiocchi-Mazzotta) X linker (CSO, Florence, Italy) at Siena University by the same authors. Pre- and post-op examinations included UCVA, BSCVA, corneal topography, and surface aberrometry (CSO Eye Top, Florence, Italy), at 48 months followup. Results. At 48 months followup paediatrics, intermediate, and adult patients showed a mean gain in UCVA of +0.2, +0.14 and +0.12 Snellen lines. BSCVA gained by a mean of +0.21, +0.2, and +0.1 ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
The device is designed for automatic testing of the degree of discharge of tractive storage batteries (AB) for electric loaders, electric cars and electric ore locomotives. The basic electrical schematic of the device is cited.
For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...
A device made of amorphous silicon which exhibits inductive properties at certain voltage biases and in certain frequency ranges in described. Devices of the type described can be made in integrated circuit form.
A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185
Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...
Single-event burnout (SEB) sensitivity was tested for power MOSFET devices, JTMCS081 and JTMCS062, which were made in Institute of Microelectronics, Chinese Academy of Sciences, using californium-252 simulation source. SEB voltage threshold was found for devices under test (DUT). It is helpful for engineers to choose devices used in satellites. (authors)
An integrated mirrorless bistable optical device based on the Mach-Zehnder interferometric optical switch has been proposed and demonstrated experimentally using a Ti:LiNbO3 waveguide. The resulting device is capable of combining more than two of them to realize multifunctional optical devices such as optical multivibrators.
We discuss the initial development of a concentrator device based on the GaInP/GaAs monolithic tandem cell structure. The very high one-sun efficiency of this device, coupled with its characteristic low operating current, make this a promising candidate for use under high concentration. Test results for a prototype device are presented. This device achieves an efficiency of 29.5% at a concentration of 102 suns.
Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).
A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.
Achieving device independence for software applications is required for all but a small number of critical real time applications. Device independence is achieved by establishing protocols and building protocol interpreters for the specific devices. Data structures containing pointers to functions provide a flexible architecture for implementing protocol translation. 3 refs., 5 figs.
In the PV system with storage batteries, as a maximum power point tracking (MPPT) device is used to enhance battery charging, the enhancement must be greater than the internal loss of the device itself, or there will be no net gain at all. To evaluate the MPPT device benefits under different climate, the theoretical calculation models have been constructed. By simulation, a comparative study between two types of PV charge controllers with and without a MPPT device under different atmospheric conditions was presented. The comparison was made by means of the energy production obtained from the PV generator of each system. The climatic conditions of Beijing and Guangzhou in China have been regarded. From the results obtained it can be concluded that the effectiveness of the MPPT device in Guangzhou is not very obvious, however the MPPT device did greatly enhance ...
This paper presents a rationale for and a summary of tasks and missions to which mobile and stationary robots and other teleoperator-controlled devices could be assigned in response to the accidental release of radioactive and other hazardous/toxic materials to the environment. Many of these vehicles and devices currently support operation and maintenance of nuclear power plants and other nuclear industry facilities. This paper also discusses specific missions for these devices at the Three Mile Island and Chernobyl nuclear power plant sites at the time of the accidents. Also discussed is the status of devices under development for future applications, as well as research on robotics.
Choosing a medical device is complex and requires a transparent process based on reason, evidence and assessment of prioritized public health needs. Poor choices lead to inappropriate use or non-use of medical devices and a waste of resources.This report suggests how an agenda to improve access to appropriate medical devices could be devised from applying the crucial 4 components - Availability, Accessibility, Appropriateness, and Affordability, to the 15 global high-burden diseases and some cross-cutting issues. The results of this exercise suggest several areas of research necessary to help
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
The effects of lead on the development of the nervous system are of immediate concern to human health. While it is clear that lead can affect neuronal development at levels of exposure within the range found in the environment, the particular mechanism of the disruption is not readily ascertained. The goal of the authors research is to develop a model system in which the effects of lead on central nervous system development can be demonstrated. To study neuronal development in a system that minimizes such difficulties, the authors have grafted discrete brain regions derived from rat fetuses into the anterior chamber of the eye of adult hosts. The brain pieces continue organotypic development in the eye, but are isolated from possible secondary changes due to alterations in the development of the endocrine and other somatic systems because the adult host has these systems already fully developed. Using this system, they have discovered that lead ...
Objective: The aim of this study was to compare symptoms and anterior segment tolerability with short-term (3-day) administration of once-daily timolol hemihydrate 0.5%, timolol maleate in sorbate 0.5%, and generic timolol maleate gel-forming solution 0.5% in the treatment of glaucoma and/or ocular hypertension. Methods: In this prospective, randomized, double-masked, active-controlled, 3-period crossover pilot study, eligible patients had primary open-angle, pigmentdispersion, or exfoliation glaucoma, and/or ocular hypertension in >=1 eye; had a best corrected visual acuity of 1.0 or better in each eye, as measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity testing chart; were receiving 1 glaucoma medication; and had an untreated intraocular pressure (IOP) ...
A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8--13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, the authors investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C{sub 3} and C{sub 4} and comparing the effects of an active and an inactive digital mobile radio telephone (GSM) system. During exposure of nearly 3.5 min to the 900 MHz electromagnetic field pulsed at a frequency of 217 Hz and with a pulse width of 580 {micro}s, the authors could not detect any difference in the ...
The author describes the history of the Soviet Unions nuclear weapons testing in Siberia from the first bomb on 29th August 1949 until the test-ban treaty of 1963. The effects of the weapons testing on the local population is only now becoming widely known. Levels of cancers and cataracts are significantly higher than in uneffected populations, and there are also high levels of some lung, bone, skin and digestive conditions. Perhaps the most important information relates to cataracts, previously thought to be caused by single large bursts of radiation. Regulatory authorities worldwide will need to tighten the safety limits for eye radiation exposure to these findings. (U.K.).
The author describes the history of the Soviet Unions nuclear weapons testing in Siberia from the first bomb on 29th August 1949 until the test-ban treaty of 1963. The effects of the weapons testing on the local population is only now becoming widely known. Levels of cancers and cataracts are significantly higher than in uneffected populations, and there are also high levels of some lung, bone, skin and digestive conditions. Perhaps the most important information relates to cataracts, previously thought to be caused by single large bursts of radiation. Regulatory authorities worldwide will need to tighten the safety limits for eye radiation exposure to these findings. (U.K.).
...The RSPB: Birds by family: Owls E-mail to a friendE-newsletterContact us Home England Northern Ireland Scotland Wales About Overview Awards & recognition Contact ...Birds by family PrintHome Birds and wildlife Bird guide Birds by family Owls Owls Owls are specialised birds with round heads and rather flat ...or dished faces, with forward-facing eyes and a short, hooked bill. Most are nocturnal or crepuscular (active at dawn and dusk)... Owls are found all over the temperate and tropical parts of the world. Barn owl With heart shaped face, buff back ...
A critical element of a retinal prosthesis is the stimulating electrode array, which is placed in close proximity to the retina. It is via this retinal-electrode interface that a retinal prosthesis electrically stimulates nerve cells to produce the perception of light. The impedance load seen by the current driver consists of the tissue resistance and the complex electrode impedance. The results in this paper show that the tissue resistance of the retina is significantly greater than that of the vitreous humor in the eye. Circuit models of the electrode-retina interface are used to parameterize the different contributors to the overall impedance. PMID:17325413
Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).
These studies were undertaken to assess the effects of increased galactose (v increased glucose) metabolism via the polyol pathway on vascular filtration function in the kidneys, eyes, nerves, and aorta. Quantitative radiolabeled tracer techniques were used to assess glomerular filtration rate (GFR) and regional tissue vascular clearance of plasma 131I-bovine serum albumin (BSA) in five groups of male Sprague-Dawley rats: nondiabetic controls, streptozotocin-diabetic rats, nondiabetic rats fed a 50% galactose diet, diabetic rats treated with sorbinil (an aldose reductase inhibitor), and galactose-fed rats treated with sorbinil. Sorbinil was added to the diet to provide a daily dose of approximately .2 mmol/kg body weight. After 2 months of diabetes or galactose ingestion, albumin clearance was increased twofold to fourfold in the eye (anterior uvea, choroid, and retina), sciatic nerve, aorta, and kidney; GFR was increased approximately twofold ...
The theoretical performance of ideal single- and multijunction cells are compared at 100xconcentration under a range of cloudless-sky conditions. The sensitivities of device performance to cell temperature and spectral variations are shown to depend on the number of junctions (one, two or three), the way in which the junctions are connected (series, parallel or independent), and the band gaps of the devices. The average performances of all of the multijunction devices surpass that of a single-junction GaAs device, but the inconsistency in performance of some of the multijunction devices is significant for large variations in cell temperature and incident spectrum. The choice of band gap and connection scheme is more important than the number of junctions in determining the consistency of device performance. (orig.).
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...
In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)
Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
Science and technology could be revolutionized by quantum computers, but building them from solid-state devices will not be easy. Robert W Keyes of IBM's research division outlines the challenges in scaling up the technology from lab experiments to practical devices. (U.K.)
... Biomedical Engineering Optical and Photonic Materials and Devices Fundamental Optical Interactions ... of Texas Medical School OPTICAL AND PHOTONIC MATERIALS AND DEVICES Gary Bjorklund, IBM, Chair Nan ...
The patent relates to fluid operated devices for moving articles. The machine may be used in filling a nuclear fuel canister with fuel pellets where there is a tendency for out of squareness of pellets to produce a jam condition readily cleared by a modest force. (U.K.).
A device for reducing the muzzle blast and flash from large caliber guns is disclosed. A container having a plurality of internal chambers and baffle plates filled with an aqueous foam is mounted to the muzzle of the gun barrel. The foam and chambers co-o...
Coke-fired cupola furnaces were improved and made suitable for the production of high-quality casting melts by numerous additional devices. Moreover, they were equipped with environmental protection systems with numerous dust separation devices and afterb...
The purpose of this study was to determine whether the use of wheeled mobility devices differed with respect to age, gender, residential setting, and health-related factors among older adults. A total...Full Text Available
In this paper we discuss the effect on the emittance of the residual dispersion in the insertion devices. The dispersion in the straights could be generated by the lattice error, trim dipole, and insertion device. The effect on the emittance is examined, and the dispersion tolerances are given for the NSLS-11.
This design manual contains descriptions of design procedures and operating experience to date, including results obtained, for secondary flow pollution control devices. Two types of combined sewer overflow regulators are described: the swirl and the helical bend regulator/separa...
The biomechanical nature of the arterial system and its major disease states provides a series of challenges to treatment strategies. Endovascular device design objectives have mostly centered on short-term...Full Text Available
BackgroundDuring surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device...Full Text Available
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
Advanced techniques for focused-ion-beam (FIB) device modification have been developed for complex, multistep modifications to circuitry on planar chip technology. Applying gas-assisted etching (GAE) techniques for high-aspect-ratio milling and the selective milling of both conductive and insulating films enhances process latitude. Localized ion-beam-induced deposition of an insulating film provides reconstructive capability in previously modified areas. The application of both techniques for complex device modification on VSLI devices fabricated with CMOS process technology is reviewed. (UK).
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.
This paper discusses design considerations for the recently introduced GaInP/GaAs monolithic tandem concentrator cell. The prototype device achieves a peak efficiency of 30.2% in a range of 140--180 suns, making this the first two-terminal device to demonstrate a verified efficiency exceeding 30%. At 425 suns the efficiency is still above 29%. The authors focus on the issues of grid design, top-cell thickness, and antireflectance coat. They also examine ways in which these aspects of the device may be modified to provide further performance improvements for future devices.
sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...
The individuality of production devices should be taken into account when statistical models are designed for parallelized devices. In the present work, a new clustering method, referred to as NC-spectral clustering, is proposed for discriminating the individuality of production devices. The key idea is to classify samples according to the differences of the correlation among measured variables, since the individuality of production devices is expressed by the correlation. In the proposed NC-spectral clustering, the nearest correlation (NC) method and spectral clustering are integrated. The NC method generates the weighted graph that expresses the correlation-based similarities between samples, and the constructed graph is partitioned by spectral clustering. A new statistical process monit...
A slurry intake device is proposed which contains an inlet sleeve, housing with grating installed with the discharge end in the zone of the slurry outlet, and hinged deflector. In order to conserve the clay mud, it is equipped with a tie rod and two-arm lever which is kinematically linked to the deflector and the grating. It is installed by hinges in relation to the housing and the latter is attached by hinges to the inlet sleeve. The deflector is arranged in the zone of slurry outlet. The device is distinguished by the fact that the deflector is equipped with a cantilever on which a fixable weight is attached.
Resistance exercise has been widely reported to have positive rehabilitation effects for patients with neuromuscular and orthopaedic conditions. This paper presents an optimal design of magneto-rheological fluid dampers for variable resistance exercise devices. Adaptive controls for regulating the resistive force or torque of the device as well as the joint motion are presented. The device provides both isometric and isokinetic strength training for various human joints.
A self-organizing particle swarm is presented. It works in dissipative state by employing the small inertia weight, according to experimental analysis on a simplified model, which with fast convergence. Then by recognizing and replacing inactive particles according to the process deviation information of device parameters, the fluctuation is introduced so as to driving the irreversible evolution process with better fitness. The testing on benchmark functions and an application example for device optimization with designed fitness function indicates it improves the performance effectively.
A method and apparatus is provided for detecting explosives by thermal imaging. The explosive material is subjected to a high energy wave which can be either a sound wave or an electromagnetic wave which will initiate a chemical reaction in the explosive material which chemical reaction will produce heat. The heat is then sensed by a thermal imaging device which will provide a signal to a computing device which will alert a user of the apparatus to the possibility of an explosive device being present.
The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
The dynamic behavior of electrooptic bistable devices with delayed feedback is investigated theoretically and experimentally. The operation principle of the system is analyzed by the method of iterated maps. Stable, bistable, periodic, higher periodic, and chaotic solutions are discussed and realized experimentally by using an integrated Mach-Zehnder interferometer on LiNbO3 as a basic nonlinear element. Taking into account the periodic modulator characteristic, the application of this device as a simple and fast bistable and monostable multivibrator is demonstrated. In addition, the synchronization properties of the astable multivibrator are investigated.
The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.
This is a patent for a device to increase compaction of the loaded batch in a coking chamber that assures a balanced compaction of the batch from the upper to the bottom layer. The leveling rod has a device on the external end that causes the rod to shift vertically and bring pressure on the material and the pressing attachment. Opposite the loading hoppers of the coking chambers there are guides that ensure the rod will be sunk perpendicularly into the loaded material.
Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)
The invention concerns a container for the long term storage of irradiated nuclear reactor fuel elements, which consists mainly of a basic body, at least one lid and an outside ring shaped lid tightening device, which acts on the basic body and the lid and holds the contact surface of the lid tight against the contact surface of the basic body, where the basic body, lid and the lid tightening device consist of corrosion-proof materials. (orig./HP).
Large scale flows of liquids can be controlled by using power fluidic devices that harness the hydrodynamic properties of liquids rather than use moving parts. Included among the fluidic devices considered are fluidic pumps, reverse flow diverters, fluidic diodes and vortex amplifiers. These devices are of potential use in the nuclear industry, particularly in reprocessing. (U.K.).
The purpose of the invention is to simplify assembly and to reduce labor intensity. This is achieved by the fact that the assembly shaft is positioned in a hawser, while its wall which is turned towards the body of the installation is combined with the hawser wall, where a U shaped opening is made in the wall of the assembly shaft, along the edges of which there is a hermetically sealing device, while the bottom of the body of the offshore drilling rig is equipped with a rigid insert attached with the capability of adjoining it with the hermetically sealing device.
To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the remaining five the cyst ...
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by two radiologists. ...
Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...
Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to determine the strength ...
We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.
A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures of these species as an indication of the ...
This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.
An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted ...
This article describes a flexible and extensible infrastructure for applying Web-Technologies to embedded systems.The presented approach develops a Three-level-Architecture consisting of the embedded system, the universal Remote-Access-Server and the Remote-Access-Client. A system-spanning general interface allows the binding of embedded systems in order to access their process data. Additionally, this procedure facilitates a flexible processing of the device data, so that it is ready to be used by different control devices. To ensure flexibility - connecting different devices on the one side and providing information for different clients like PC, PDA or mobile phone on the other side - a new XML-based description language (Service Description Markup Language - SDML) is introduced. The SDML documents contain information about connected embedded systems, reusable device data and the presentation ...
An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during ...
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
The new oil price environment is sending industry engineers back to the drawing board. The search is on for cost effective and perhaps unconventional deepwater production systems. One candidate for Gulf of Mexico deepwater tracts is a tanker-based floating production, storage, and offloading (FPSO) system. Substantial experience with tanker-based FPSO systems has proven them to be cost effective when the field is remote from existing production facilities and pipelines. A tanker-based system offers the unique feature of integrating production, storage, and offloading capabilities into a single unit. Such systems can be installed in 12 to 15 months and can even be leased, significantly improving an operator's cash flow.
Zeaxanthin is a carotenoid produced by plants and has been associated with protection of the photosynthetic machinery under light stress and, together with lutein, in protection of the central retina of the eye. Zeaxanthin levels in blood plasma have been negatively correlated to the development of AMD (age-related macular degeneration) (Gale et al., 2003). Under normal conditions, plants have a low content of zeaxanthin. The aim of this study was to increase the zeaxanthin content in green vegetables by post harvest treatments. Efficient conditions for activation of the endogenous enzyme system generating zeaxanthin was established and included incubation at low pH (2.5-5.5), with the membrane permeable acetic acid/acetate buffer at room temperature or above for 30min or more. Typically m...
This study provides a comprehensive description of the main morphological and histological events that take place during larval and post-larval development of Senegal sole Solea senegalensis in order to establish a reference for its normal developmental organogenesis. Five stages have been described. Before gill development at the onset of metamorphosis (eye migration process, stage 4c), the skin was the main site of gas and ion exchange, whereas during stages 3 and 4, the skin begins differentiating into the definitive juvenile structure. The timing of development of the endocrine system depends on each organ, the endocrine pancreas and thyroid gland being the first to differentiate (stages 2 and 3, respectively), followed by the interrenal tissue and stannius corpuscles that develop at m...
This study examined the extent to which science, technology, engineering, and math (STEM) students reported having had mentors of their own race and gender and the extent to which they have adopted the idea that matching by race and gender matters. The study also documented the effects of race and gender matching on three academic outcomes, self-reported grade point average, efficacy, and confidence, based on data collected from 1,013 undergraduate and graduate students and postdoctoral scholars actively participating in MentorNet's online community. Analyses indicated that having a mentor of one's own gender or race was felt to be important by many students, especially women and students of Color. Students who had a mentor of their own gender or race reported receiving more help, but matc...
Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and ...
Landscapes are both a synthesis and an expression of national, regional and local cultural heritages. It is therefore very important to develop techniques aimed at cataloguing and archiving their forms. This paper discusses the LDL (Landscape Digital Library) project, a Web accessible database that can present the landscapes of a territory with documentary evidence in a new format and from a new perspective. The method was tested in a case study area of the river Po valley (Northern Italy). The LDL is based on a collection of photographs taken following a systematic grid of survey points identified through topographic cartography; the camera level is that of the human eye. This methodology leads to an innovative landscape archive that differs from surveys carried out through aerial photographs or campaigns aimed at selecting "relevant" points of interest. Further developments and possible uses of the LDL are also discussed.
The number of immigrants to Western Europe has been increasing, with immigration the subject of much controversy in contemporary Europe. In this article, we investigate the relationship between the size of the immigrant population, how natives perceive this size, and their anti-immigrant attitudes. We use data from the 2002/2003 European Social Survey covering 17 Western European countries, and we find that as a rule Western Europeans think that the immigrant population in their country is much larger than it actually is. The perceived size of an immigrant population has an impact on anti-immigrant prejudices, but the real size does not. Like many authors before us, we find that education reduces prejudice. However, we also find that around 10 percent of the total effect of education is a ...
Myotonic dystrophy type 1 (DM1) is characterized by both a premature appearance of age-related phenotypes and multiple organ involvement, which affects skeletal and smooth muscle as well as the eye, heart, central nervous system, and endocrine system. Although erectile dysfunction (ED) is a frequent complaint in patients with DM1, it has not been investigated in great depth. Hypogonadism, which is reported to be one of the physical causes of ED in the general population, frequently occurs in DM1. We planned this case?control study to evaluate the relationship between hypogonadism, as defined by the sexual hormone profile (FSH, LH, testosterone (T) and prolactin) and ED, as assessed by means of an internationally validated self-administered questionnaire (IIEF). DM1 patients had significant...
The glass gene is required for proper photo-receptor differentiation during development of the Drosophila eye glass codes for a DNA-binding protein containing five zinc fingers that we show is a transcriptional activator. A comparison of the sequences of the glass genes from two species of Drosophila and a detailed functional domain analysis of the Drosophila melanogaster glass gene reveal that both the DNA-binding domain and the transcriptional-activation domain are highly conserved between the two species. Analysis of the DNA-binding domain of glass indicates that the three carboxyl-terminal zinc fingers alone are necessary and sufficient for DNA binding. We also show that a deletion mutant of glass containing only the DNA-binding domain can behave in a dominant-negative manner both in vivo and in a cell culture assay that measures transcriptional activation. PMID:7604032
Purpose To investigate the influence of timolol maleate 0.5% gel-forming solution and brinzolamide 1% ophthalmic suspension on contrast sensitivity, ocular higher-order aberration (HOA), and corneal surface light scattering. Design Prospective, comparative study. Participants Forty normal volunteers were enrolled in this study. Methods We evaluated contrast sensitivity, ocular HOA, and corneal light scattering before and 2, 5, 10, and 15 minutes after instillation of antiglaucoma eyedrops. Contrast sensitivity function was assessed with the CSV-1000RN chart (Vector Vision Co., Greenville, OH). Higher-order aberration was measured for a 4-mm pupil using the Hartmann-Shack aberrometer (KR-9000PW; Topcon, Tokyo, Japan). Corneal surface light scattering was quantitatively evaluated by using th...
To test the hypothesis that transduction of the channelrhodopsin-2 (ChR2) gene, a microbial-type rhodopsin gene, into retinal ganglion cells of genetically blind rats will restore functional vision, we recorded visually evoked potentials and tested the experimental rats for the presence of optomotor responses. The N-terminal fragment of the ChR2 gene was fused to the fluorescent protein Venus and inserted into an adeno-associated virus to make AAV2-ChR2V. AAV2-ChR2V was injected intravitreally into the eyes of 6-month-old dystrophic RCS (rdy/rdy) rats. Visual function was evaluated six weeks after the injection by recording visually evoked potentials (VEPs) and testing optomotor responses. The expression of ChR2V in the retina was investigated histologically. We found that VEPs could not b...
Objective Infectious endophthalmitis is among the most serious complications of cataract surgery. Gram-negative bacteria, including Pseudomonas aeruginosa, are responsible for less than 30% of cases; however, their rapidity of infection and virulence often results in poor visual outcome despite prompt antibiotic treatment. The purpose of this study was to investigate an outbreak of post-cataract surgery P. aeruginosa endophthalmitis in India. Design Hospital-based case series. Participants Twenty patients with acute postoperative endophthalmitis who underwent cataract surgery at one of the peripheral centers of Joseph Eye Hospital, Tiruchirapalli, Tamil Nadu, India, from February 23 to April 2, 2008. Interventions Vitreous aspirates and environmental surveillance specimens were inoculated ...
Aim: To determine whether experience improves the consistency of visual search behaviour in fracture identification in plain radiographs, and the effect of specialization. Material and methods: Twenty-five observers consisting of consultant radiologists, consultant orthopaedic surgeons, orthopaedic specialist registrars, orthopaedic senior house officers, and accident and emergency senior house officers examined 33 skeletal radiographs (shoulder, hand, and knee). Eye movement data were collected using a Tobii 1750 eye tracker with levels of diagnostic confidence collected simultaneously. Kullback-Leibler (KL) divergence and Gaussian mixture model fitting of fixation distance-to-fracture were used to calculate the consistency and the relationship between discovery and reflective visual search phases among different observer groups. Results: Total time spent studying the radiograph was not significantly different between the groups. However, the ...
White spot syndrome virus (WSSV) is the causative agent of the white spot disease of shrimp. Penaeus monodon were captured from Muttukadu Estuary in Chennai, India, transported to the laboratory and maintained in an aerated system with continuous water circulation-biofiltration. WSSV-free P. monodon were challenged by feeding them only once with WSSV-infected tissues of P. monodon. Cumulative mortality (100%) of the infected individuals was determined. Tissues from infected and uninfected shrimp such as muscles, hepatopancreas, heart, gills and eye tissues (100mg of each) and haemolymph (50 microl) were subjected to SDS-PAGE. In infected muscle tissue, six newly expressed proteins were detected. In infected haemolymph, four new proteins and three intensely expressed high molecular weight proteins were observed. Three intensely expressed high molecular weight proteins were detected in infected heart tissue and two new proteins in infected hepatopancreatic tissues. ...
The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, the following estimates can be derived by ...
The first part of a systematic investigation is presented of surface treatments affecting the fatigue behavior of smooth and notched quenched and tempered (Q and T) specimens made of a B-Mn SS2131 ({approx}AISI 15B21H) steel. In this part, the effects of plasma nitriding (nitriding temperature=480 C, time=24 h) on the fatigue strength and notch sensitivity were investigated. Constant stress amplitude plane reversed bending fatigue tests (R=-1) at 47 Hz were conducted using cylindrical plasma nitriding (PN) and Q and T steel specimens with K{sub t}=1.05 and 1.7. The compound layer was found to consists of {epsilon}-phase and {gamma}`-phase. S-N curves show that plasma nitriding improves the fatigue limit by 53 and 115% of Q and T smooth and notched specimens, respectively. The fatigue strength of smooth specimens is improved through the whole fatigue life but only for long fatigue lives for notched specimens. Plasma nitriding reverses the low notch sensitivity (at short lives) and high ...
Environmental and breathing zone samples were analyzed for formaldehyde at the Pikes Peak Dialysis Center, Colorado Springs, Colorado in August, 1984 and February, 1985. The evaluation was requested by a representative of the Center to determine if there was a health hazard due to formaldehyde. Eight employees were interviewed. The ventilation systems were investigated. Personal protective clothing was inspected. Breathing-zone samples contained 0 28 to 1.0 (mg/m/sup 3/) formaldehyde. The OSHA standard for formaldehyde is 3.7 mg/m/sup 3/. Area formaldehyde concentrations ranged from nondetectable to 0.75 mg/m/sup 3/. Health complaints reported included sore throat, congestion, cough, and eye, nose and throat irritation. Most of the complaints originated from employees in the formalin mixing, reuse sterilization, and dialysis unit packing sections. The exhaust system in the reuse sterilization area was not working efficiently. A variety of personal protective ...
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
We have investigated tailoring damage effects of explosive devices by addition of unconventional materials, specifically combustible metals. Initial small-scale as well as full-scale testing has been performed. The explosives functioned to disperse and ignite these materials. Incendiary, enhanced-blast, and fragment-damage effect have been identified. These types of effects can be used to extend the damage done to hardened facilities. In other cases it is desirable to disable the target with minimal collateral damage. Use of unconventional materials allows the capability to tailor the damage and effects of explosive devices for these and other applications. Current work includes testing of an incendiary warhead for a penetrator.
High power and particle deposition on target materials are encountered in many applications including magnetic and inertial fusion devices, nuclear and high energy physics applications, and laser and discharge produced plasma devices. Surface and structural damage to plasma-facing components due to the frequent loss of plasma confinement remains a serious problem for the Tokamak reactor concept. The deposited plasma energy causes significant surface erosion, possible structural failure, and frequent plasma contamination.
Field Programmable Gate Arrays (FPGAs) are being used in space applications because of attractive attributes: good density, moderate speed, low cost, and quick turn-around time. However, these devices are susceptible to Single Event Upsets (SEUs). An approach using triple modular redundancy (TMR) and feedback was developed for flip-flop hardening in these devices. Test data showed excellent results for this circuit topology. Total dose and Single Event Effect (SEE) testing have been performed on recently released technologies. Failures are analyzed and test methodology is discussed.
Recently, organic semiconducting materials have gained a broad interest due to their potential for organic electronic devices such as organic light emitting diode (OLED), organic photovoltaic devices and organic field-effect transistors (OFETs). Optical properties of organic semiconducting materials are important for practical application. For example, the power conversion efficiency of organic photovoltaic devices is mainly affected by absorption properties of organic materials. Proton irradiation is one of the efficient methods to change the optical properties of organic materials. In this paper, we investigate the changes of optical properties of various polymers using the proton irradiation.
The saturation of free electron laser (FEL) output power by the KHI-FEL device was achieved on 3rd, October 2000 at the wavelength of 9.3 #mu#m. The FEL device has operated thereafter successfully in the wavelength region between 4.0 and 16.0 #mu#m. The macropulse average FEL power of 37.5 kW, which is the theoretical saturation level, has been obtained at the wavelength of 7.9 #mu#m. The net FEL gain was estimated to be 16%. (author)
Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.
In the well-known devices for increasing the decontamination factor in the treatment of radioactive waste water by evaporation, which consist of narrowing devices with evaporator sump and condenser, droplets of liquid and solid particles are carried over from the breeder space, which are radioactive and therefore make the decontamination factor worse. Better results are obtained if one places a fibre bed filter between the evaporator sump and the condenser, preferably in a horizontal connecting pipe between the evaporator sump and the condenser.
Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical ...
The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...
The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. Percutaneous routes that ...
SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...
The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
... The acousto-optic device have a 30 MHz 1 ... coherent systems including compact non-coherent optical ... a relatively simple phase switching approach. ...
BackgroundThe routine removal of orthopaedic fixation devices after fracture healing remains an issue of debate. There are no evidence-based guidelines on this matter, and little...Full Text Available
... electronic feedback system' connected to a Q switch ... The use of acousto-optic (AO) beam steering devices for BMDO (SDI) applications is very ...
A silicon solar cell assembly comprising a large, thin silicon solar cell bonded to a metal mount for use when there exists a mismatch in the thermal expansivities of the device and the mount.
Introduction: Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. Methods: Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipien...
We report on studies of device degradation in organic photovoltaic devices based on blends of poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl C61-butyric acid methyl ester (PCBM). Since delamination, oxidation, and chemical interactions at the metal electrode/organic interface have long been posited as degradation pathways in organic electronic devices, we first investigated the stability of a variety of electrodes for devices stored in an inert, dark environment. Second, a set of experiments was designed to separate the effects at the metal/organic interface from the degradation of the active layer or the hole extraction interface. To do this, Ca/Al electrodes were deposited to complete half of a substrate's devices, and samples were left both under constant illumination and 10% illumination (10% duty cycle of 1 sun illumination) in a glovebox environment. After more than ...
Wave energy device teams have identified three varieties of air turbine as potentially applicable to wave energy devices. These are: conventional axial turbines; Wells, or self-rectifying, axial turbines and Francis turbines. This report examines the constructional requirements of these devices with regard to mechanical, environmental and manufacturing considerations. It is concluded that the major benefit of optimum material selection will be reduced manufacturing costs rather than enhanced turbine performance. A methodology of material selection has been established and candidate materials have been listed for the major components of each turbine type. Comparative costs for alternative materials are included, from which significant, potential economies have been identified. Recommendations are made aimed at achieving optimum material usage in the proposed turbines.
Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection...Full Text Available
Pd/n-Si and Pd/n-GaAs devices have been irradiated from high energy ({approx}100 MeV) heavy ions of Au{sup 7+} (gold) and Si{sup 7+} (silicon) to study the irradiation effects in these junction devices on semiconductor substrates. The devices have been characterized from I-V and C-V studies for electronic flow characterization. It has been found that the devices become high resistive on the irradiation and the substrates change the conductivity type from n- to p- on the irradiation of fluence of {approx}10{sup 12}-10{sup 13} ions/cm{sup 2}. The change in conductivity type has been understood as a result of creation of deep acceptors on the irradiation.
The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
... Thus. thi, characteristic further buggeots, other things unchanging, that the more *multifunction" the ccna ;Ituent devices ari., t~he more efficienit the ...
A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this ...
With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...
A device is described for transporting loads, especially for moving belt driving stations in open pit mining operations with a propelling mechanism which for lifting a respective load is operable to move into a free space formed by the load with the ground. The device comprises a plurality of lifting mechanisms, by means of which, a lifting platform can be brought into engagement with a supporting surface of the load. The device comprises at least one supporting member which is so designed that it prevents the lifting platform from lifting off lifting mechanisms. Furthermore, means are provided which permit a turning of the lifting platform relative to the lifting mechanisms about a vertical axis which is arranged in a certain relationship to the propelling mechanism.
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid ...
... with the ability to capture imagery in raw 24-bit format, combined with large memory storage devices enable high resolution imagery to be captured ...
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...
The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.
The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.
We demonstrate a two-dimensional device simulator for MOSFET structures that incorporates models for defect distributions and show predicted effects on device switching performance for various spatial distributions of defects in amorphous and polycrystalline silicon.
Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A ...
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.
The NREL Sensitized Solar Cell (SSC) Core Program supports the Solar America Initiative by: (1) targeting new devices and processes for commercialization by 2015 that are less expensive, more efficient, highly reliable, and environmentally benign; (2) collaborating with DOE OS/BES to conduct basic research targeting breakthroughs in key areas, such as ultra-high efficiency and/or ultra-low cost materials and devices.
We study the uniqueness of solutions of a semilinear elliptic problem obtained from an inverse formulation when the nonlinear terms of the equation are prescribed in a general class of real functions. The inverse problem arises in the modeling of the magnetic confinement of a plasma in a Stellarator device. The uniqueness proof relies on an L"#infinity# -estimate on the solution of an auxiliary nonlocal problem formulated in terms of the relative rearrangement of a datum with respect to the solution.
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
Biased above threshold (VT), pulsed photocurrent (u) measurements on windowed silicon Pd gate MOS capacitors are shifted (DV) negatively by H2/N2, whereas Au gates shift positively under NO2/air. Below VT, the shifts are reversed by adjustments of interface state population. Minor temperature increases may coax the device from inversion to depletion, inducing sign reversal of the chemical response.
Heterodyne detection with a point-contact Josephson junction has been investigated both experimentally and theoretically. The measured performance of the device at 36 GHz is in good agreement with the theory. By operating vanadium point contacts at 1.4 K, the authors have achieved a single-sideband (SSB) mixer noise temperature of 54 K with a conversion gain of 1.35 and a signal bandwidth on the order of 1 GHz. A potentially impressive performance for these devices at submillimeter wavelengths can be extrapolated from the results.
In response to severe maintenance problems caused by the highly corrosive toxic and radioactive substance used in the nuclear reprocessing industry, AEA Technology (formerly the United Kingdom Atomic Energy Authority) has developed a series of power fluidics devices with no moving parts. These maintenance-free devices are described in this article which also explores applications in fields outside their original brief. (UK).
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
The results show that the SQUID device eddy current testing system is a suitable tool for NDE. Due to the high low-frequency sensitivity of the SQUID sensor, the SQUID device eddy current testing system permits lower examination frequencies than the conventional eddy current probe system. The SQUID system enhances fault detection in even deeper materials layers. (orig./MM).
First Solar made 9 CdTe PV devices; found two front- and one back-side structures that show improved Jsc and Voc, respectively, compared to base device structure; best cell efficiency was 14.13%.
An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.
The device is made by a tool at the end of a flexible cable, a motor for the rotation of the flexible, a linear drive with a guide for it between the winder and the tube.
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
A device for marking and searching for information on a magnetic carrier is described. In order to increase the noise immunity and reliability of the data recording and reading paths, the recording head is included between the amplifier of the clock pulses for the master oscillator and through the amplifier of the code pulses for the logical element unit. The reproduction head is connected through the code pulse shaper-amplifier with a switch which is connected with the display unit, and through another analogous clock pulse amplifier with a multivibrator.
A device for laying cut peat in drying formations is proposed consisting of separate compartments, reinforced on a common frame and with mechanisms for both vertical and horizontal mixing. In order to intensify the drying process, within the scope of laying cut peat, uniform clearances and spacing in formations is applied. The mixing compartments are joined in sections with capabilities for separate mixing in each unit. The compartments are joined together by hinges and can be turned 180 degrees on the hinges horizontal to the plane.
The purpose of this research was to investigate the de-entrainment of boron for evaporators used in nuclear power plants. The forced circulation and semi-continuous type evaporator was used in the experiment. Cyclone and glass-wool packed column which is supposed to provide good decontamination factor as well as easy maintenance, were selected as de-entrainment device to be used in the evaporation of radioactive liquid wastes. The de-entrainment device combined with cyclone and glass-wool column has shown overall DF more than 1000 for boron.
We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.
The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).
Purpose: To ensure continuous operation for condensate desalters with the control device for desalter group in a nuclear power plant by automatically averaging the operation interval between each of the desalters. Constitution: Electroconduction meters are provided at the inlet and the outlet for each of the desalters. The conduction rates at the inlet and outlet are compared to determine the re-generation timing of the condensate desalter. Limiting set value for each of the equipments in the cleanup systems is changed by using a mathematical operation circuit to average the operation interval between each of the desalters. (Ikeda, J.).
A continuous-flow filter/concentrator for separating and/or concentrating particles in a fluid is disclosed. The filter is a three-port device an inlet port, an filter port and a concentrate port. The filter separates particles into two streams by the ratio of their dielectrophoretic mobility to their electrokinetic, advective, or diffusive mobility if the dominant transport mechanism is electrokinesis, advection, or diffusion, respectively.Also disclosed is a device for separating and/or concentrating particles by dielectrophoretic trapping of the particles.
The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).
A string sieve is proposed which includes a frame, a sifting surface made of string, a device for attaching the strings made in the form of rollers installed in staggered order and a tensing device attached to traverses. To improve the effectiveness of sifting by self cleaning of the sifting surface during operation, the rollers are installed on the traverses by means of a unit of hinges, whose elastic elements are made with varying rigidity.
Three instruments for measuring local velocities in liquid-metal MHD experiments for fusion blanket applications are being evaluated. The devices are used in room-temperature NaK experiments to measure three-dimensional flow field patterns anticipated in complex blanket geometries. Hot film anemometry, a standard technique in ordinary fluids, is being used, as well as two developmental devices. One is called the Liquid Metal Electromagnetic Velocity Instrument (LEVI), and performs essentially as a local dc electromagnetic flow meter. The third device, a Thermal Transient Anemometer (TTA) is a rugged, yet relatively simple device, which measures local velocity through the mechanism of convective heat transfer, in some ways similar to hot-film anemometry. Results are presented showing the kinds of data collected this far with each instrument. Measurements include both local velocity measurements and some ...
Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field ...
Room temperature continuous wave operation of red ([lambda][sub 0] [approximately] 660 nm) vertical cavity surface emitting laser arrays is reported. The 1 [times] 64 arrays have a pitch of 100 [mu]m with device diameters of 15 [mu]m with device diameters of 15 [mu]m. Grown by metalorganic vapor phase epitaxy, the devices consist of an AlGaInP strained quantum well optical cavity active region surrounded by AlGaAs distributed Bragg reflectors (DBR's). The top coupling DBR includes a partial dielectric stack, deposited after implanted device fabrication. All 64 devices operation simultaneously with peak output powers >0.45 mW, threshold current <1.5 mA, and threshold voltages [<=] 2.7 V. The differential quantum efficiencies exceed 10%.
We report on studies of field-effect transistor (FET) and transparent thin-film transistor (TFT) devices based on lightly Ta-doped SnO2 nano-wires. The nanowire-based devices exhibit uniform characteristics with average field-effect mobilities exceeding 100 cm2/V x s. Prototype nano-wire-based TFT (NW-TFT) devices on glass substrates showed excellent optical transparency and transistor performance in terms of transconductance, bias voltage range, and on/off ratio. High on-currents and field-effect mobilities were obtained from the NW-TFT devices even at low nanowire coverage. The SnO2 nanowire-based TFT approach offers a number of desirable properties such as low growth cost, high electron mobility, and optical transparency and low operation voltage, and may lead to large-scale applications of transparent electronics on diverse substrates. PMID:17595151
A non-synthetic polymer material, polyterpenol, was fabricated using a dry polymerization process namely RF plasma polymerization from an environmentally friendly monomer and its surface, optical and electrical properties investigated. Polyterpenol films were found to be transparent over the visible wavelength range, with a smooth surface with an average roughness of less than 0.4 nm and hardness of 0.4 GPa. The dielectric constant of 3.4 for polyterpenol was higher than that of the conventional polymer materials used in the organic electronic devices. The non-synthetic polymer material was then implemented as a surface modification of the gate insulator in field effect transistor (OFET) and the properties of the device were examined. In comparison to the similar device without the polymer insulating layer, the polyterpenol based OFET device showed significant improvements. The addition of the ...
A 72-year-old man was exposed to the sarin gas attack in a Tokyo subway on March 20 th, 1995. After exposure, he noticed eye discomfort, chest tightness, headache and weakness of the lower limbs and oropharyngeal muscles. Despite these symptoms, he visited a hot spring on the same day with his family. On March 25 th, his muscle weakness progressed, and a low grade fever appeared. His muscle weakness disappeared 8 days after exposure to sarin, but respiratory failure rapidly developed, necessitating artificial ventilation within four day after hospitalization on March 28th. Chemotherapy with erythromycin, imipenem/cilastatin, and steroid pulse therapy was begu. PCR and culture of sputum collected by bronchofiberscopy were positive for Legionella pneumophila, serogroup I. His respiratory state improved, but subsequent infection with Pseudomonous aeruginosa. Enterobacter cloacae, and Candida tropicalis/glabrata caused his death 71 days after admission. Oropharyngeal ...
The intention of this study is to show the high potential of remote sensing data to keep an eye on longterm processes in large regions with widespread tasks and questions. The results of two projects (sponsored by the BMBF - Ministry of Education and Science, Germany and the country of Saxony-Anhalt) are taken into account to give an impression of the chances provided by the application of hyperspectral airborne scanner data and satellite images. So these two projects focus at the applicability of various methods to use remote sensing data for a long- term monitoring of former lignite open-cast mining areas. Apart from the traditional pixelorientated analysis, the application and combination of new object orientated methods (e.g. segmentation, texture analysis) were investigated to distinguish between the following typical vegetation types: Spontaneous revegetation of plant communities; reforestation areas; recultivated grass seeding areas; area patterns of ...
Internet bandwidth is in high demand, and one way that web sites lower the amount of bandwidth they use is by compressing their site's images. This lowers the amount of bandwidth used, and makes the site load much faster. There are of course many other useful applications for compressed images. Bit Plane Complexity Segmentation (BPCS) digital picture steganography is a technique to hide data inside an image file. BPCS achieves high embedding rates with low distortion based on the theory that noise-like regions in a bit-plane can be replaced with noise-like secret data without discernible loss in image quality. This is possible because the human eye, while very good at distinguishing anomalies in areas of homogenous texture, is bad at distinguishing anomalies in visually complex areas. However, BPCS is not a robust embedding scheme, and any lossy compression usually destroys the data. Wavelet image compression using the Discreet Wavelet Transform (DWT) is the basis ...
Lutein is a yellow pigment found in common foods that promotes the health of eyes and skin and is associated with reduced risk of age-related macular degeneration and cataracts. In the present study, selected high-lutein wheat and corn were milled into wholegrain flours by two mills to improve flour uniformity. The high-lutein and lutein-fortified wholegrain flours were processed into breads, cookies, and muffins to study lutein stability during baking and subsequent storage. Lutein and its isomers were separated, identified, and quantified by LC-UV/vis and LC-MS following extraction with water-saturated 1-butanol. Baking resulted in a significant reduction in all-trans-lutein and the formation of cis-lutein and cis-zeaxanthin isomers. Subsequent storage at ambient temperature had a slight impact on the content of all-trans-lutein. Effects of processing were more pronounced in lutein-fortified products, and the degradation rate of lutein was influenced by ...
Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical dosage from containing the above-mentioned ...
This report highlights the Pipeline integrity Management methods being implemented by gas companies. These aim at maintaining the current high safety level, prevent major hazards, ensure the integrity of the pipeline and protect people and environment in the vicinity of the pipeline in the most cost effective way. It should be noticed that Pipeline Integrity Management aspects, technical and organisational, are included in the more general framework of the Safety Management System. Currently, more and more gas companies implement such a system on the basis of standards like ISO 9000 and so on. In this way, the report shows how practices of Pipeline Integrity Management are continually developing in order to adapt to their environment, and to improve performance. Past experience and imminent developments show that Pipeline Integrity Management is a flexible and efficient approach to improve safety in the long term. Consequently, Pipeline Integrity Management Systems are, under the ...
Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, ...
PurposeTo evaluate the efficacy of photorefractive keratectomy (PRK) for residual refractive error after penetrating keratoplasty (PKP) for keratoconus. SettingPrivate ophthalmic clinic. DesignCase series. MethodConsecutive patients who had PRK augmented with topical mitomycin-C (MMC) after PKP for keratoconus were retrospectively reviewed. Patients were divided into a a low cylinder group (refractive cylinder 6.00 D). Visual acuity, refraction, and keratometry were analyzed preoperatively and 1, 3, 6, and 12 months postoperatively. ResultsThe study comprised 47 eyes (41 patients). The spherical equivalent (SE) decreased from -4.24 D +- 3.23 (SD) preoperatively to -0.71 +- 1.03 D 12 months postoperatively in the low cylinder group and from -4.19 +- 3.54 D to -2.45 +- 3.42 D, respectively, ...
The retinal degeneration 10 (rd10) mouse is a well-characterized model of autosomal recessive retinitis pigmentosa (RP), which carries a spontaneous mutation in the ? subunit of rod cGMP-phosphodiesterase (PDE?). Rd10 mouse exhibits photoreceptor dysfunction and rapid rod photoreceptor degeneration followed by cone degeneration and remodeling of the inner retina. Here, we evaluate whether gene replacement using the fast-acting tyrosine-capsid mutant AAV8 (Y733F) can provide long-term therapy in this model. AAV8 (Y733F)-smCBA-PDE? was subretinally delivered to postnatal day 14 (P14) rd10 mice in one eye only. Six months after injection, spectral domain optical coherence tomography (SD-OCT), electroretinogram (ERG), optomotor behavior tests, and immunohistochemistry showed tha...
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple algorithm is orders of magnitude faster than the CCCS method. Without pre-calculation of beamlets, its ...
We explore as clearly as possible the features of neutrino oscillation which are relevant for measurements of the CP violating Kobayashi-Maskawa phase delta and the sign of \\Delta m^2_{13}. We focus on the so called low-energy option and discuss principles for optimizing experimental parameters to measure these two quantities simultaneously. Toward the goal, we first formulate a method for obtaining a bird-eye view of the phenomenon of neutrino oscillation by introducing a new powerful tool called the ``CP trajectory diagram in bi-probability space''. It allows us to represent pictorially the three effects separately in a single diagram; effect from genuine CP violation due to the sin delta term, effect from the CP conserving cos delta term, and the fake CP violating effect due to earth matter. By using the CP trajectory diagram we observe that there is a two-fold ambiguity in the determination of delta which is related with the sign of Delta m^2_{13}. We then ...
There are many factors contributing to the changes taking place within the electric utility industry. The environmental pressures on the industry are substantial and include the global warming issue, hazardous and nuclear waste challenges, air toxicities, and the electromagnetic field controversy. An issue of special concern is deregulation of the industry, which brought with it retail wheeling, wholesale wheeling, transmission access, and market-based pricing, all of which have greatly shaken the industry. The changes are expected to happen quickly. This is quite different from the 31 years it took to deregulate the telecommunications industry, the 15 to 20 years for railroads, the 9 years for the natural gas industry, and the 2 years for the airline industry. Historically there has been a general willingness among the utilites to share information through collaborative research. Research and development is viewed as a cost and not an investment in the electric utility business. This ...
Delta Scorpii is a double giant Be star in the forefront of the Scorpio, well visible to the naked eye, being normally of magnitude 2.3. In the year 2000 its luminosity rose up suddenly to the magnitude 1.6, changing the usual aspect of the constellation of Scorpio. This phenomenon has been associated to the close periastron of the companion, orbiting on a elongate ellipse with a period of about 11 years. The periastron, on basis of high precision astrometry, is expected to occur in the first decade of July 2011, and the second star of the system is approaching the atmosphere of the primary, whose circumstellar disk has a H-alpha diameter of 5 milliarcsec, comparable with the periastron distance. The preliminary results of a photometric campaign, here presented in the very days of the periastron, show an irregular behavior of the star's luminosity, which can reflect some shocks between material around the two stars. The small luminosity increasement detected in the ...
Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using PET and ...
This paper reports on the detection of optical novae in our neighbour galaxy M31 based on digitized historical Tautenburg Schmidt plates. The accurate positions of the detected novae lead to a much larger database for searches for recurrent novae in M31. We conducted a systematic search for novae on 306 digitized Tautenburg Schmidt plates covering a time span of 36 years from 1960 to 1996. From the database of both ~ 300 000 light curves and about one million detections on only one plate per colour band, nova candidates were efficiently selected by automated algorithms and subsequently individually inspected by eye. We report the detection of 84 nova candidates. In detail we found 55 nova candidates from the automated analysis of the light curves. Among these, 22 were previously unknown, 12 were known but have not been identified on Tautenburg Schmidt plates before and 21 novae have been discovered on Tautenburg plates previously. An additional 29 known novae could ...
Dozens of universities--primarily from the United States, United Kingdom, and Australia--are eyeing the Gulf region as a largely untapped reservoir of academic potential and economic opportunity. During the last few years, UAE states like Dubai, Abu Dhabi, Qatar, and Ras al Khaymah have spent billions to entice top universities. And many colleges are responding--examples include New York University's campus in Abu Dhabi; Michigan State University's school in Dubai; and big names like Cornell, Northwestern, and Carnegie Mellon that have set up shop in Qatar. Typically, Western universities begin their foray into the Gulf by teaming with local investors. The colleges oversee the academic infrastructure while the investors front all operational costs. The partnerships are complicated. Some investors are mining the UAE's educational zeal for profit. In other cases, schools join forces with the region's numerous royal families, who are mostly interested in furthering ...
The purpose of the Microelectronic Evaluation Laboratory at Sandia is to develop a program for evaluating CMOS LSI (complementary metal oxide silicon - large scale integrated) technology devices which are being used for the first time in a weapon system. These evaluations are based on accelerated aging studies and electrical tests to determine the reliability and life of the devices. In accelerated aging, specific, controlled stresses are applied to the device to accelerate time-to-failure. Data are used tin mathematical models to estimate life in acutal use. The stresses used for this technology are temperature and voltage. The devices are stored at temperatures with or without voltage applied (steady-state or cyclical) and periodically tested until at least 50% failures are encountered. Since most current technologies use epoxy-die-attachment, aging temperatures must be under 200/sup 0/C. This delays ...
The adhesion of a Mg:Ag cathode to the tris-(8-hydroxyquinoline) aluminum (Alq{sub 3}) in organic light emitting devices (OLEDs) can be greatly enhanced by a remote plasma treatment of the Alq{sub 3} layer using either air or N{sub 2} prior to metal deposition. The altered surface properties which lead to increased sticking coefficients of Mg and Ag, as well as enhanced adhesion, are attributed to the introduction of new functional groups into the organic layer, as observed by X-ray photoelectron spectroscopy (XPS). The storage life of the plasma treated devices in air without any capping treatment, as judged by a visible deterioration of the cathode, was increased by approximately five to six times compared to untreated OLEDs. Current-voltage characteristics and EL efficiency, however, were shown to deteriorate for devices incorporating either an air or an N{sub 2} plasma treated Alq{sub 3} layer. For OLEDs subjected to ...
This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential ...
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
Individuals who use augmentative and alternative communication (AAC) depend on technology to meet their daily needs and form relationships. Speech generating devices (SGDs) are integral components of communication systems. Reliability of SGDs is critical for effective use in everyday life. This study examined the reliability of new SGDs and found that mean time to first failure was 42.7 (SD = 41.2) weeks and at least 40% required repairs within the first year of use. The components that most frequently broke down were touch screens, wiring, main boards, batteries, memory cards, and AC adaptors. The costs of repairing SGDs were analyzed. The clinical implications of device breakdown are identified for key stakeholders, including clients, families, service providers, funding agencies, and ma...
The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).
One of the issues with printers - or the increasingly common multi-function devices (MFDs) - is that no one takes any notice of them. They just sit there, unacknowledged and ignored, in the corner of the office, printing, photocopying, faxing and even emailing away and no one gives them a second thought. Until something goes wrong. No-one gives printers - or multi-function devices (MFDs) - a second thought, as they have just been sitting there in offices doing their thing for years. But the problem is that they have now grown up to become fully-fledged computers and are starting to present an information security risk. These machines now have operating systems, hard drives and IP addresses, and have been exploited as storage devices by hackers. But most problems stem from poor internal pra...
Photoemission-electron-microscopy (PEEM) is introduced as a tool for the characterization of organic electronic devices. PEEM-measurements are used for imaging as well as for spectroscopic analyses by illumination with light of a Hg-lamp (4.9 eV), a D2 lamp (7.3 eV), and with synchrotron radiation for resonant photoelectron spectroscopy. We determine the charge carrier concentration inside the channel region of the organic device and its lateral distribution. From resonant photoelectron spectroscopy (RPES) we deduce the electronic states which are accessible with the Hg and D2 illumination. Photoelectron-spectroscopy at selected areas ({mu}-PES) gives information on the absolute values of surface potentials in lateral resolution. We are able to perform these studies with applied voltages at the source- and drain-electrode.
The metallo-organic chemical vapor deposition (MOCVD) process has been used with great success to grow AlGaAs-GaAs and InGaAsP-InGaAs-InP heterostructure materials for electronic and optoelectronic applications. Devices fabricated from Al/sub x/Ga/sub 1-x/As-GaAs heterostructures grown by MOCVD include bipolar transistors, field-effect transistors (FETs), high-mobility (or modulation-doped) FETs, large-area high-efficiency solar cells, low-threshold lasers, high-power lasers, quantum-well lasers, and visible lasers. The state of the art for the MOCFD growth of optoelectronic devices is reviewed in this paper, and some comments are made regarding future trends in the growth of these materials by MOCVD.
A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of ...
A new class of low aspect ratio toroidal hybrid stellarators is found using a more general plasma confinement optimization criterion than quasisymmetrization. The plasma current profile and shape of the outer magnetic flux surface are used as control variables to achieve near constancy of the longitudinal invariant J{sup {asterisk}} on internal flux surfaces (quasiomnigeneity), in addition to a number of other desirable physics target properties. A range of compact (small aspect ratio A), low plasma current devices have been found with significantly improved confinement, both for thermal as well as energetic (collisionless) particle components. With reasonable increases in magnetic field and geometric size, such devices can also be scaled to confine 3.5 MeV alpha particle orbits.
A new class of low aspect ratio toroidal hybrid stellarators is found using more general plasma confinement optimization criterion than quasi-symmetrization. The plasma current profile and shape of the outer magnetic flux surface are used as control variables to achieve near constancy of the longitudinal invariant J* on internal flux surfaces (quasi-omnigeneity), in addition to a number of other desirable physics target properties. We find that a range of compact (small aspect ratio A), high {beta} (ratio of thermal energy to magnetic field energy), low plasma current devices exist which have significantly improved confinement both for thermal as well as energetic (collisionless) particle components. With reasonable increases in magnetic field and geometric size, such devices can also be scaled to confine 3.5 MeV alpha particle orbits.
Google's Android is a comprehensive software framework for mobile communication devices (i.e., smartphones, PDAs). The Android framework includes an operating system, middleware and a set of key applications. The incorporation of integrated access services to the Internet on such mobile devices, however, increases their exposure to damages inflicted by various types of malware. This paper provides a comprehensive security assessment of the Android framework and the security mechanisms incorporated into it. A methodological qualitative risk analysis that we conducted identifies the high-risk threats to the framework and any potential danger to information or to the system resulting from vulnerabilities that have been uncovered and exploited. Our review of current academic and commercial solutions in the area of smartphone security yields a list of applied and recommended defense mechanisms for hardening mobile devices in ...
Trends in front-end-of-line technology are discussed. At the chip level, many of the important parameters are published in the National Technology Roadmap for Semiconductors in 1994. At the device and circuit level, both bipolar and CMOS are scalable. However, the large standby power of bipolar circuits severely limits the integration level of bipolar chips. The inherently low standby power of CMOS, on the contrary, allows the integration level of CMOS circuits to continue increasing with scaling. In reality, both the electric field and power density of CMOS devices have been gradually rising over the generations owing to non-scaling effects of thermal voltage and silicon bandgap. As power supply voltage reaches 1.5V and below, circuit performance can only be gained at the expense of higher active or standby power of the chip. Implications of device scaling on contact and silicide technology are addressed. Trends of local ...
Purpose In literature, few papers compare different hemostatic devices in laparoscopic adrenalectomy. This sequential cohort study analyzes the outcomes of laparoscopic adrenalectomy performed by different hemostatic instruments, to evaluate if any of them has any advantage over the other and as secondary endpoints, the impact of body mass index (BMI) and tumor size on the indication, and the outcome of laparoscopic adrenalectomy. Methods Forty-six patients, aged 54.6???46?years, underwent laparoscopic adrenalectomy over 5?years. Mean BMI was 27???4.8?kg/m2. Twenty-four patients had a left tumor, and 22 had a right one. Patients were divided into two groups according to the hemostatic device: Ultracision was used in 26 patients, and Ligasure was used in 20. Groups were well matched for his...
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
Thermoacoustics deals with the conversion of heat energy into sound energy and vice versa. It is a new and emerging technology which has a strong potential towards the development of sustainable and renewable energy systems by utilizing waste heat or solar energy. Although simple to fabricate, the designing of thermoacoustic devices is very challenging. In the present study, a comprehensive design and optimization algorithm is developed for designing thermoacoustic devices. The unique feature of the present algorithm is its ability to design thermoacoustically-driven thermoacoustic refrigerators that can serve as sustainable refrigeration systems. In addition, new features based on the energy balance are also included to design individual thermoacoustic engines and acoustically-driven thermoacoustic refrigerators. As a case study, a thermoacoustically-driven thermoacoustic refrigerator has been designed and optimized based on the developed ...
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).
Purpose: To flatten temperature distribution of coolant within a core. Constitution: The control device of the present invention is to vary reactivity of a fast breeder to control a reactor power. In general, the control device of this kind comprises a guide pipe arranged within the core and a control rod movable up and down within the guide pipe, and a coolant flows from bottom toward top within the guide pipe. Since a cooling flow rate has a margin, temperature of coolant outlet is extremely low as compared to a fuel assembly, and therefore temperature gradient in the vicinity of the top of the control rod becomes sharp to possibly impart thermal shock to the structural material. In the present invention, the flow passage of coolant is varied to thereby avoid outflow thereof into the core, thus flattening the temperature distribution of the coolant within the core. (Kamimura, M.).
The use of dendrimers for preparing chemically sensitive interfaces for detecting volatile organic compounds (VOCs) using surface acoustic wave (SAW) device transducers is described. Specifically, the synthesis of the dendrimers and the means by which they are affixed to SAW devices is discussed, followed by a detailed spectroscopic analysis of the surface-confined dendrimers and a discussion of their interaction with different VOCs. Most of these preliminary experiments focus on dendrimer surface modification using benzoylchloride, which leads to phenyl terminal groups linked to the dendrimer via amide groups. The results of this study lead us to conclude that dendrimers: (1) provide general specificity towards classes of functional groups and are therefore suitable for array-based sensing schemes; (2) are intermediate in structure between monolayers and polymers and exhibit the desirable properties of both; (3) can be straightforwardly ...
Course website from Cambridge on ceramic materials. This site contains eight lectures in PDF format (Adobe Reader required), two question sheets, five practicals (including answers), digital movies and further useful links. "There is a strong relationship between the structure of a material and its physical properties. The properties of a material whether mechanical, electrical, optical or magnetic, determine how it can be used in practical applications. In this course, the focus is on the structure / property relationship for ionic materials with electrical properties utilised in various transducer devices. The materials considered include perovskites, which have special polarisation properties exploited in ferroelectric, pyroelectric and piezoelectric devices. Other oxides, such as zirconia, have structures permitting rapid diffusion of ions, making them suitable for use in sensors, fuel cells and batteries. The scientific principles ...
The article is aimed to design and testing of joystick with force feedback used in direct, human control of lifting device. The paper starts with the basic description of designed and tested by us MR rotary brake. Some initial laboratory investigations results of such brakes are presented. The usage of MR brakes in 2 axis joystick is proposed. Such, built by as joystick, is described. It was used as Human-Machine Interface in active control of lifting device. The designed and built 2 axis manipulator with electrohydraulic drive is described. In the paper, the based on PC with input/output card, control system of mentioned above joystick with MR brake and manipulator is described. Finally the control algorithm is proposed.
In this work, we investigated self-heating related instability in polysilicon thin film transistors (poly-Si TFTs) fabricated on polyimide (PI) substrates. Indeed, when Joule heating becomes relevant, the temperature of the active layer can substantially rise, since the devices are fabricated on thermally insulating substrates. As a result, electrical instability is triggered and attributed to the generation of interface states, due to the Si-H bond breaking, and charge trapping into the gate insulator. In addition, by using 3-dimensional numerical simulations, coupling the thermodynamic and transport models, we analyzed the temperature distribution of the device under operating conditions and found that self-heating is more severe for devices fabricated on plastic substrates.
A novel floating-gate avalanche injection (FAMOS) type erasable programmable read-only memory (EPROM) device is demonstrated, with a heavily focused ion-beam (FIB) implanted region of about 0.2-..mu..m width at the drain edge of the channel. This heavily B/sup +/-doped region permits a higher electric field near the drain edge, resulting in a remarkable increase of the hot-carrier generation rate, and reduces both the programming voltage and programming time. A three-dimensional device simulator, CADDETH, predicted that the electric field at the drain edge would increase by about six times, which would lead to hot-carrier generation efficiency three orders of magnitude higher.
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
The waterjet technique enables precise tissue dissection without thermal damage and with preservation of vessels in general surgery. In neurosurgery, these qualities could help to avoid damage of intact brain parenchyma in tumour resections. The present study reports our first results with this technique in brain metastases. Ten patients with intracranial metastases underwent surgery with the aid of the waterjet. Resection was performed in combination with conventional neurosurgical methods. The follow-up consisted of neurological examination and MRI studies. Intraoperatively, the device was easy to handle. No complications due to the device were observed. Vessels were preserved at pressures below 20 bars. Six of the tumours consisted of soft tissue which was poorly demarcated from the surrounding brain. In these tumours, the waterjet was very helpful. It enabled tumour debulking by aspiration and - more important - precise separation of tumour ...
The PVSCAN is an instrument designed to characterize silicon solar cell materials and devices. It performs a host of measurements that yield spatial maps of dislocation density, grain distribution, reflectance, and photoresponses from near-junction and the bulk of a solar cell.
Isokinetic training and assessment of the knee joint has been the mainstay of rehabilitation, especially in patients with anterior cruciate ligament deficiency. Besides the original shin pad used, the...Full Text Available
The DataAccessBean is similar to the Data Access Object (DAO) interface in that the DataAccessBean interface is meant to encapsulate the implementation details of the DynamicJavaBean that accesses persistent storage devices such as RDBMS, flat text file databases, etc.
The effect of reinforcement in the cross-linked poly(propylene fumarate-co-caprolactone diol) thermoset composites based on Kevlar fibres and hydroxyapatite was studied. Cross-linked poly(propylene...Full Text Available
Every cook knows that microwaves and metal don't mix. But scientists at the National Institute of Standards have devised a way to make them compatible. If it all pans out, hospitals may be able to sterilize medical instruments and waste in a device similar to a conventional microwave oven.
... Oliver, j. Egekeze, m. 7. Kennedy, JW Jorgenson, J. F. Parcher and ... 9. .:. W. Thackeray, HS White and MS Wrighton, J. Phys ... Dr. Harold H. Singerman ...
Beta silicon carbide is an excellent candidate semiconductor material for demanding applications in high power and high temperature electronic devices due to its high breakdown voltage, relatively large band gap, high thermal conductivity and high melting...
A simple device is described which is used to determine treatment distance and beam direction in electron therapy employing one collimation. A technique for the production of irregular field templates and localization films is given.
A theoretical framework centering on four classes of self-referent constructs is offered as a device for integrating the diverse areas constituting medical sociology. Guidance by this framework...Full Text Available
SummaryBackgroundThe US FDA has been collecting information on medical devices involved in significant adverse advents since 1984. These reports have...Full Text Available
BackgroundEfficient and safe transection of biological tissue in liver surgery is strongly dependent on the ability to address both parenchymal division and hemostasis simultaneously....Full Text Available
...broad range of experience in designing and building research and development laboratories for products such as vaccines, blood and sera, biological products, medical devices, solid dosage forms , highly potent products and cytotoxic material. We also have experience in a range of modular laboratories for TSE research, ...
Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. Experimental data taken for 2k-gate test chips ...
Quantum computers hold great promises for the future of computation. In this paper, this new kind of computing device is presented, together with a short survey of the status of research in this field. The principal algorithms are introduced, with an emphasis on the applications of quantum computing to physics. Experimental implementations are also briefly discussed.
BackgroundThe aim of this double-blind randomized study is to test the efficacy of a radio electric stimulator device using an auricular reflex therapy protocol for stress-related...Full Text Available
When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.
An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to help plasma formation. ...
In this article are presented main results on electric potential investigations in stellarator/torsatron TJ-II and tokamak T-10 in a comparable regimes of device operation.
Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available
Purpose:To evaluate the midterm efficacy and safety of the iStent® glaucoma device in patients with secondary open-angle glaucoma.Patients...Full Text Available
The latest-generation cochlear implant devices provide many deaf patients with good speech recognition in quiet listening conditions. However, speech recognition deteriorates rapidly as the level of...Full Text Available
Jul 16, 2005 ... The purpose of this capability portfolio is to develop a roadmap for NASA to exploit .... 1.2.4-2: Some applications of nanotechnology to advanced EVA suits. ..... Power/Energy Storage: Materials and devices for energy storage and .... to 80 %), manufacturing costs (up to 50%) and enhancements in durability. ...
We have developed miniature (≈1 μm diameter) microcavity surface-plasmon-resonance sensors (MSPRS), integrated them with microfluidics and tested...Full Text Available
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
AIMS—(1) To validate a leg to leg bioimpedance analysis (BIA) device in the measurement of body composition in children by assessment of its agreement with dual energy x...Full Text Available
Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...
The tremendous heat generated in a computer chip or very large scale integrated circuit raises many challenging issues to be solved. Recently, liquid metal with a low melting point was established as the most conductive coolant for efficiently cooling the computer chip. Here, by making full use of the double merits of the liquid metal, i.e. superior heat transfer performance and electromagnetically drivable ability, we demonstrate for the first time the liquid-cooling concept for the thermal management of a computer chip using waste heat to power the thermoelectric generator (TEG) and thus the flow of the liquid metal. Such a device consumes no external net energy, which warrants it a self-supporting and completely silent liquid-cooling module. Experiments on devices driven by one or two stage TEGs indicate that a dramatic temperature drop on the simulating chip has been realized without the aid of any fans. The higher the heat load, the larger ...
The sensitive explosives used in initiating devices like primers and detonators are called primary explosives. Successful detonations of secondary explosives are accomplished by suitable sources of...Full Text Available
The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.
Various electrochemical capacitors (ultracapacitors) are being developed for hybrid vehicles as candidate power assist devices for the fast response engine. The primary functions of the ultracapacitor are to level the dynamic power loads on the primary propulsion device and recover available energy from regenerative breaking during off-peak power periods. Ultracapacitors show promise toward being able to accept high regenerative pulses while exhibiting very high cycle life. This paper will present test data from selected US Department of Energy (DOE) supported ultracapacitor projects designed to meet the fast response engine requirements. Devices containing carbon, conducting polymers, and metal oxide electrode materials in combination with aqueous or organic electrolytes are being supported by the DOE. This paper will present and discuss testing data obtained from recent prototype capacitors supplied by Maxwell Energy ...
An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.
Porous Nitinol (PNT) has found vast applications in the medical industry as interbody fusion devices, synthetic bone grafts, etc. However, the tendency of the PNT to corrode is anticipated to...Full Text Available
Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is...Full Text Available
IntroductionFlow diversion is a new approach to the endovascular treatment of intracranial aneurysms which uses a high density mesh stent to induce sac thrombosis. These devices...Full Text Available
Methodologies are given for conducting studies to discover and map break deformations in coal strata using various modifications on radiometry, together with the field for their use. Results that were obtained using the IKS-50 device are given.
Automated, variable volume unloaders provide the ability to smoothly load/unload reciprocating compressors to maintain ideal operations in ever-changing environments. Potential advantages provided by this load control system include: maximizing unit capacity, optimizing power economy, maintaining low exhaust emissions, and maintaining process suction and discharge pressures. Obstacles foreseen include: reliability, stability, serviceability and automation integration. Results desired include: increased productivity for the compressor and its operators, increased up time, and more stable process control. This presentation covers: system design features with descriptions of how different types of the devices were developed, initial test data, and how they can be effectively operated; three actual-case studies detailing the reasons why automated, hydraulically controlled, variable volume, head-end unloaders were chosen over other types of unloading ...
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between ...
Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.
We demonstrate tuning of Schottky energy barriers in organic electronic devices by utilizing chemically tailored electrodes. The Schottky energy barrier of Ag on poly[2-methoxy], 5-(2{prime}-ethyl-hexyloxy)- 1,4-phenylene was tuned over a range of more than 1 eV by using self-assembled monolayers (SAM{close_quote}s) to attach oriented dipole layers to the Ag prior to device fabrication. Kelvin probe measurements were used to determine the effect of the SAM{close_quote}s on the Ag surface potential. {ital Ab} {ital initio} Hartree-Fock calculations of the molecular dipole moments successfully describe the surface potential changes. The chemically tailored electrodes were then incorporated in organic diode structures and changes in the metal/organic Schottky energy barriers were measured using an electroabsorption technique. These results demonstrate the use of self-assembled monolayers to control metal/organic interfacial electronic properties. ...
A controlled bidirectional quantum secret direct communication scheme is proposed by using a Greenberger-Horne-Zeilinger (GHZ) state. In the scheme, two users can exchange their secret messages simultaneously with a set of devices under the control of a third party. The security of the scheme is analysed and confirmed.
The present invention concerns a device for peeling off activated concretes in processing for discarding a reactor of a nuclear reactor facility. The device comprises a gyrotron for generation microwaves, an irradiator for irradiating output microwaves, a reflection mirror for reflecting and converging the microwaves and irradiating them to a material to be irradiated and a first rotating means for rotating the irradiator and the reflection mirror in parallel with the axis of the gyrotron while maintaining the positional relation between the irradiator and the reflection mirror. When the position of the microwaves irradiated on concrete walls are moved in a circumferential direction and the central axes of the rotational axis and the material to be irradiated are aligned, then the intensity of the irradiation of the microwaves at each of the irradiation points can be maintained constant without changing the focal distance of the reflected ...
The Marcy Wedge-Pro (MWP), a device used in training by tennis players, was employed in the assessment of tennis elbow. The MWP was used to measure the ability of patients to perform wrist extension...Full Text Available
A pneumatic device is in the form of a U-shaped frame, on which a prong is attached by using two pairs of levers. It also has a hydraulic or pneumatic cyclinder, whose rod is connected to one of the pairs of levers. All connections are hinges.
Functionalizing of single molecules on surfaces has manifested great potential for bottom-up construction of complex devices on a molecular scale. We discuss the growth mechanism for the initial layers...Full Text Available
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the ...
The stand is designed to test supports of development workings. To expand the test range for various types of supports, the cross pieces have fixing devices in the form of winches interacting by cables through blocks fastened to the stand body with the support hinges.
IntroductionA rare side effect of antipsychotic medication is neuroleptic malignant syndrome, mainly characterized by hyperthermia, altered mental state, haemodynamic dysregulation,...Full Text Available
BackgroundHip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly...Full Text Available
The primary method for neuronal communication involves the extracellular release of small molecules that are packaged in secretory vesicles. We have developed a platform to separate, lyse, and...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
... 2010-10-01 2010-10-01 false Battery installation. 393.30 Section 393.30...Devices, and Electrical Wiring § 393.30 Battery installation. Every storage battery on every vehicle, unless located in...
The AlGaInP materials system has recently supported the development of a variety of visible diode laser devices at wavelengths ranging from yellow to red. Presently, the majority of published results are with materials prepared by organometallic vapor phase epitaxy (OMVPE). Many issues with such materials exist, including impurity doping, the role of crystal ordering, defect formation during epitaxial growth, and the proper quantum well heterostructure design required for best device results. This paper addresses these topics and reviews the present state of the art, and projects the anticipated results when the materials' problems have been solved.
An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.
This patent describes an automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves on the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first.
In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.
Polymer electrolyte membrane fuel cells (PEMFCs) are energy conversion devices that produce electricity from a supply of fuel, such as hydrogen. One of the major challenges in achieving efficient energy conversion is the development of cost-effective materials that can act as electrocatalysts for PEMFCs. In this letter, we demonstrate that, instead of conventional noble metals, such as platinum, chromium nitride nanocrystals of fcc structure exhibit attractive catalytic activity for PEMFCs. Device testing indicates good stability of nitride nanocrystals in low temperature fuel cell operational environment.
One of the major scientific and technological challenges for the production of flexible organic electronic devices is the device protection against atmospheric molecule permeation, which causes corrosion reducing its operation and lifetime. In this work, Spectroscopic Ellipsometry has been implemented to investigate the influence of silicon dioxide nanoparticles on the optical properties of hybrid polymers. The spectra analysis revealed valuable information about the electronic and vibrational response as well as the cross-linking mechanisms of these materials. The correlation of the optical properties with the synthesis parameters and the barrier response will contribute towards their optimization in order to be used as high barrier coatings for flexible organic electronics applications.
Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity
The authors have measured the noise of MOS transistors of the United Technology Microelectronics Center (UTMC) 1.2 [mu]m radiation hardened CMOS P-well process from the weak to moderate inversion region. The noise power spectral densities of both NMOS and PMOS devices were measured from 1 KHz to 50 MHz. The bandwidth was chosen such that the important components of the spectral densities such as the white thermal noise and the 1/f noise could be easily resolved and analyzed in detail. In this paper the effects of different device terminal DC biases and channel geometries on the noise are described.
We study a quantum computing system using microwave photons in transmission line resonators on a superconducting chip as qubits. We show that linear optics and other controls necessary for quantum computing can be implemented by coupling to Josephson devices on the same chip. By taking advantage of the strong nonlinearities in Josephson junctions, photonic qubit interactions can be realized. We analyze the gate error rate to demonstrate that our scheme is realistic even for Josephson devices with limited decoherence times. As a conceptually innovative solution based on existing technologies, our scheme provides an integrated and scalable approach to the next key milestone for photonic qubit quantum computing.
Background This report describes the authors? experience with a unique endoluminal, endoscopically delivered and retrieved gastroduodenojejunal bypass sleeve, including short-term weight loss and changes in comorbidities. Methods A prospective, single-center trial was designed. The patients were morbidly obese individuals who met the National Institutes of Health criteria for bariatric surgery. The device used was a unique gastroduodenojejunal bypass sleeve secured at the esophagogastric junction with endoscopic and laparoscopic techniques and designed to create an endoluminal gastroduodenojejunal bypass. At completion of the trial, the device was explanted with endoscopic retrieval. The primary end points were safety and incidence of adverse events. The secondary outcomes included the per...
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
The ubiquitous presence of mobile communication devices and the continuous development of mo- bile data applications, which results in high level of mobile devices' activity and exchanged data, often transparent to the user, makes privacy preservation an important feature of mobile telephony systems. We present a formal analysis of the UMTS Authentication and Key Agreement protocol, using the applied pi-calculus and the ProVerif tool. We formally verify the model with respect to privacy properties. We show a linkability attack which makes it possible, for individuals with low-cost equipment, to trace UMTS subscribers. The attack exploits information leaked by poorly designed error messages.
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
This report considers the effect of pipe-whip restraints and snubbers on the normal operation of piping systems in nuclear power plants. Also considered are the effect of these postulated event devices on reliability, economics, and the exposure of plant personnel to radiation. Field data were gathered from three nuclear power plants that had applied for Operating Licenses. Criteria, design philosophies, and data were obtained from the respective nuclear steam system suppliers, architects-engineers and utilities.
Negative ion based neutral beam injector is one of the most attractive heating system in future fusion reactors. In realizing the system, the crucial device which has to be developed is a high intensity negative ion source. Significant progress has been made on the negative ion source in these years. Among them, a few ampere negative ion beam were produced stably, while the divergence of negative ion beams becomes to be as low as < 10 mrad. We consider these results are demonstrating the potential of the negative ion source for the heating device in future reactors.
The fire protection practices adopted at nuclear power stations generally follow the well established principles used throughout industry. Unfortunately, there is one particular area - the interaction with heating, ventilation and air conditioning (HVAC) services - where nuclear power stations pose a seemingly insoluble conflict: that between the need to contain and the need to ventilate. Now, however, solid state fire dampers using power fluidics may promise a solution. One of the key characteristics of a fluidic device is that it is 'solid state', i.e. it has no moving parts. Because of this, its inherent reliability is orders of magnitude greater than a mechanical device. (U.K.).
A probabilistic method for assessing the profitability of reactive power compensation devices such as capacitors, static VAR compensators and generators, which improve network security, was described. Since network development is limited by environmental constraints, power networks are operated close to their limits. Because of this fact transmission network planning increasingly relies on techno-economic models to improve network security and profitability. The proposed method consists of analyzing large numbers of constrained power system states, extracted from power system simulation exercises. The paper describes details of the method and provides an example of a numerical application on a part of the French power transmission system. 10 refs., 8 figs.
This paper is a quarterly report describing the use of a new soil gas collection device which allows the collection of soil gas in the field for later analysis in the laboratory. It describes the installation of this sampling device and the procedure for setting the probe, extraction of soil gas beneath the surface, and sealing of the soil gas for transport. The sites used for initial testing was the top of Yucca Mountain and Crystal Spring in Ash Meadows National Wildlife Refuge. The results from this initial test showed no volatile matter present in the soil at these locations.
Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.
The organization of organic semiconductor molecules in the active layer of organic electronic devices has important consequences to overall device performance. This is due to the fact that molecular organization directly affects charge carrier mobility of the material. Organic field-effect transistor (OFET) performance is driven by high charge carrier mobility while bulk heterojunction (BHJ) solar cells require balanced hole and electron transport. By investigating the properties and device performance of three structural variations of the fluorenyl hexa-peri-hexabenzocoronene (FHBC) material, the importance of molecular organization to device performance was highlighted. It is clear from {sup 1}H NMR and 2D wide-angle X-ray scattering (2D WAXS) experiments that the sterically demanding 9,9-dioctylfluorene groups are preventing {pi}-{pi} intermolecular contact in the hexakis-substituted FHBC 4. For ...
Optogenetics, the ability to use light to activate and silence specific neuron types within neural networks in vivo and in vitro, is revolutionizing neuroscientists' capacity to understand how defined neural circuit elements contribute to normal and pathological brain functions. Typically, awake behaving experiments are conducted by inserting an optical fiber into the brain, tethered to a remote laser, or by utilizing an implanted light-emitting diode (LED), tethered to a remote power source. A fully wireless system would enable chronic or longitudinal experiments where long duration tethering is impractical, and would also support high-throughput experimentation. However, the high power requirements of light sources (LEDs, lasers), especially in the context of the extended illumination periods often desired in experiments, precludes battery-powered approaches from being widely applicable. We have developed a headborne device weighing 2 g capable of wirelessly ...
Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, measurements have ...
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert auf die Bestimmung ...
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...
The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did not differ from that observed by 99mTc-sulfur colloid scan or ...
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two patients with larger ...
PPARgamma agonists have been proposed to exert more than metabolic benefits, particularly by anti-inflammatory mechanisms. We hypothesized that pioglitazone might modulate inflammatory and vascular responses to lipopolysaccharide (LPS). In a placebo-controlled parallel-group study in 18 healthy male subjects, the E. coli endotoxin model of inflammation (20 IU/kg i. v.) was employed to test the effect of 60 mg pioglitazone over nine days on inflammatory cytokines. Macrovascular function and microvascular blood flow were assessed by brachial artery ultrasound and retinal blood flow parameters, respectively. Pioglitazone increased brachial artery diameter by 5.6% but had no effect on other outcome parameters under resting conditions. LPS increased cytokine levels to peak concentrations of 91.3+/-22.5 ng/ml (IL-6), 261.4+/-60.0 ng/ml (TNFalpha), and 524.5+/-15.3 ng/ml (VCAM-1). The endotoxin caused microvascular vasodilation and increased retinal white blood cell flux, ...
Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this ...
Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of ...
We wanted to evaluate the correlation of mild renal pelvic dilatation (RPD) that is observed to be less than 10 mm on ultrasound (US) with urinary tract infection (UTI) and vesicoureteral reflux (VUR) in neonates. We reviewed 137 kidneys of 107 neonates who had RPD less than 10 mm on US. All the kidneys were divided into two groups: Group I (RPD <= 5.0 mm) and Group II (RPD > 5.0 mm), and we statistically analyzed the RPD change according to UTI and VUR. Seven neonates had VUR (5.1%), and there was no statistical significance between Group I (6 neonates, 5.6%) and Group II (1 neonate, 3.3%). Thirty seven cases (27%) had UTI and there was no statistical significance between Group I (30 cases, 28.0%) and Group II (7 cases, 23.3%). The RPD did not change in 81.8% of the cases, it increased in 4.4% of the cases and it decreased in 13.9% of the cases on follow up US. The incidence of VUR and UTI were not different according to the change of RPD. There were ...
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...
Classical semiconductor physics has been continuously improving electronic components such as diodes, light-emitting diodes, solar cells and transistors based on highly purified inorganic crystals over the past decades. Organic semiconductors, notably polymeric, are a comparatively young field of research, the first light-emitting diode based on conjugated polymers having been demonstrated in 1990. Polymeric semiconductors are of tremendous interest for high-volume, low-cost manufacturing (''printed electronics''). Due to their rather simple device structure mostly comprising only one or two functional layers, polymeric diodes are much more difficult to optimize compared to small-molecular organic devices. Usually, functions such as charge injection and transport are handled by the same material which thus needs to be highly optimized. The present work contributes to expanding the knowledge on the physical ...
The Ranque-Hilsch tube is a particular type of vortex tube device. The flow enters the device tangentially near one end and exits from the open ends of the tube. The inlet air is of a uniform temperature throughout while the outputs are of different temperatures. One outlet is hotter and the other is colder than the inlet air. This device has no moving parts and does not require any additional power for its operation other than that supplied to the device to compress the inlet air. It has, however, not been widely used, mainly because of its low efficiency. In this paper, a simplified 2-dimensional computational fluid dynamics model for the flow in the vortex tube is developed using FLUENT. This model makes use of the assumption of axial symmetry throughout the entire flow domain. Compared to a three-dimensional computational solution, the simplified model requires significantly less computational time. ...
The results of experiments with a short period (9.6 mm) wiggler sheet electron beam (1.0 mm x 2.0 cm) millimeter-wave free electron laser (FEL) amplifier are presented. This FEL amplifier utilized a strong wiggler field for sheet beam confinement in the narrow beam dimension and an offset-pole side-focusing technique for the wide dimension beam confinement. The beam analysis herein includes finite emittance and space-charge effects. High-current beam propagation was achieved as a result of extensive analytical studies and experimental optimization. A design optimization resulted in a low sensitivity to structure errors and beam velocity spread, as well as a low required beam energy. A maximum gain of 24 dB was achieved with a 1-kW injected signal power at 86 GHz, a 450-kV beam voltage, 17-A beam current, 3.8-kG wiggler magnetic field, and a 74-period wiggler length. The maximum gain with a one-watt injected millimeter-wave power was observed to be over 30 dB. The lower gain at higher ...
Embryos of chicken (Gallus domesticus), domestic duck (Anas platyrhynchos), and common eider duck (Somateria mollissima) were exposed in ovo to PCBs and to polycyclic aromatic hydrocarbons. Two coplanar PCBs, 3,3{prime},4,4{prime}-tetrachlorobiphenyl (PCB {number_sign}77) and 3,3{prime},4,4{prime},5-pentachlorobiphenyl (PCB {number_sign}126), were considerably more lethal and potent as inducers of 7-ethoxyresorufin O-deethylase (EROD) in chicken embryos (Gallus domesticus) than in embryos of the other two species. In chicken embryos, these compounds caused edema and eye and beak deformities. An artificial mixture of 18 PAHs which all have been detected in environmental samples, was slightly more toxic to embryos of the domestic duck and the common eider duck than to chicken embryos. The most potent compound in the mixture was benzo(k)fluoranthene. When chicken embryo livers were exposed to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) in vitro, EROD was induced by ...
The distribution of i.v. administered lead (/sup 203/Pb-acetate; 50 nmol/kg b.w.) was studied by means of autoradiography and impulse counting in pregnant C57BL mice (day 18) treated orally with dithiocarbamates. Diethyldithiocarbamate (DEDTC), disulfuram or thiram (2 X 1) mmol/kg b.w.) or vehicle (gelatine) alone, was given by gavage 2 h before and immediately after the injection of lead. All three dithiocarbamates, especially thiram, changed the distribution pattern of lead. Thiram and DEDTC had the greatest effect at 4 h after lead administration, disulfiram at 24 h. In the mother, most notably the brain concentration increased (70-fold for thiram at 4 h) while that of erythrocytes and skeleton decreased (50- and 4-fold, respectively). The total fetal concentration unexpectedly showed only a moderate increase (proportional 2-fold for thiram), which may be due partly to the low maternal plasma lead concentration. The partition within the fetal tissues was, however, changed by the ...
The distribution of i.v. administered lead ("2"0"3Pb-acetate; 50 nmol/kg b.w.) was studied by means of autoradiography and impulse counting in pregnant C57BL mice (day 18) treated orally with dithiocarbamates. Diethyldithiocarbamate (DEDTC), disulfuram or thiram (2 X 1) mmol/kg b.w.) or vehicle (gelatine) alone, was given by gavage 2 h before and immediately after the injection of lead. All three dithiocarbamates, especially thiram, changed the distribution pattern of lead. Thiram and DEDTC had the greatest effect at 4 h after lead administration, disulfiram at 24 h. In the mother, most notably the brain concentration increased (70-fold for thiram at 4 h) while that of erythrocytes and skeleton decreased (50- and 4-fold, respectively). The total fetal concentration unexpectedly showed only a moderate increase (proportional 2-fold for thiram), which may be due partly to the low maternal plasma lead concentration. The partition within the fetal tissues was, however, changed by the ...
Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for all targets and OAR with both treatment ...
Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV doses received by different groups of Finnish population. Also, an ...
Gas turbines are used where large amounts of energy is needed, typically as engines in aircraft, ferries and power plants. From an efficiency point of view it is desirable to increase the service temperature as much as possible. One of the limiting factors is then the maximum allowable metal temperatures in the turbine stages, primarily in the blades of the first stage, that are exposed to the highest gas temperatures. Specially designed materials are used to cope with these severe conditions, such as the nickel base superalloy IN792. In order to be able to design the components for higher temperatures and tighter tolerances, a detailed understanding and computationel models of the material behaviour is needed. The models presented in this work have been developed with the objective of being physically well motivated, and with the intention of avoiding excessive numbers of parameters. The influence of the parameters should also be as easy as possible to interpret. The models are to ...
Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher diagnostic accuracy in the detection of bony cage and central airway ...
Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the ...
Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the ...