Real time automatic discriminating of ultrasonic flaws
International Nuclear Information System (INIS)
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft ...
2009-07-20
High speed inverted optical-resolution photoacoustic microscopy
Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.
2011-02-01
Special phased array applications for pipeline girth weld inspections
Energy Technology Data Exchange (ETDEWEB)
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of ...
2004-07-01
Porous tooling process for manufacture of graphite/polyimide composites. Final report
Energy Technology Data Exchange (ETDEWEB)
A porous tooling system was selected for the processing of Graphite/PMR-15 Polyimide laminates in thickness up to 3.2 mm. (0.125 inch). This tool system must have a reasonable strength, permeability dimensional stability, and thermal conductivity to accomplish curing at 600 F and 200 psi and 200 psi autoclave temperature and pressure. A permeability measuring apparatus was constructed and permeability vs. casting water level determined to produce tools at three different permeability levels. On these tools, laminates of 5, 11, and 22 plies (.027, .060, and 0.121 inch) were produced and evaluated by ultrasonic, mechanical, and thermal tests to determine the effect of the tool permeability on the cured laminates. All tools produced acceptable laminates at 5 and 11 plies but only the highest permeability produced acceptable clear ultrasonic C-Scans. Recommendations are made for future ...
1981-01-01
Detection of Second-Layer Corrosion in Aging Aircraft
International Nuclear Information System (INIS)
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)
2002-03-01
Energy Technology Data Exchange (ETDEWEB)
A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems ...
2000-07-01
Particle-Sizing System for Scanning Electron Microscope ...
... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...
1991-03-01
Energy Technology Data Exchange (ETDEWEB)
Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain structures and to determine the consistency of ...
2007-01-01
Generation and control of sound bullets with a nonlinear acoustic lens
UK PubMed Central (United Kingdom)
Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available
2010-04-20
THE EFFECTS OF ONE MEGACYCLE ULTRASONIC ...
... ULTRASONIC VIBRATION TO PORTLAND CEMENT-WATER PASTE REDUCES THE ULTIMATE COMPRESSIVE STRENGTH OF MORTARS ...
1959-09-09
Development of New Ground Inspection Techniques for the ...
Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...
Energy Technology Data Exchange (ETDEWEB)
After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill inspection and manipulation requirements were ...
1994-12-31
Versatile gamma scanning system
International Nuclear Information System (INIS)
(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.
Inspection pig for gas pipeline
Energy Technology Data Exchange (ETDEWEB)
The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory ...
1992-12-31
Energy Technology Data Exchange (ETDEWEB)
Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.
2002-08-01
International Nuclear Information System (INIS)
Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.
2002-08-01
Ultrasonic Phased Array Implementation of the Inside Diameter Creeping Wave Sizing Method
Energy Technology Data Exchange (ETDEWEB)
This paper describes a technique for implementing the ultrasonic inside diameter (ID) creeping wave technique for detection and sizing ID connected defects using a phased array ultrasonic system. The technique uses multiple focal laws to produce the examination modes. The first focal law is designed to create a shear wave nominally at the critical angle for mode conversion to a longitudinal wave at the ID of a part, thus creating a creeping wave. This focal law is focused at the ID to improve sensitivity. The rest of the laws are designed to create tandem sound paths that progress up a vertical surface directly above the focal point of the creeping wave generation point. When a defect on the inner surface is detected with the creeping wave, the height of the defect can be measured from the response of a set of tandem laws without readjusting the position of the probe. Results from standard one-inch long notches of varying ...
2006-05-01
Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer
International Nuclear Information System (INIS)
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue ...
2008-05-07
Phonon relaxation and internal friction in heterogeneous systems based on poly(vinyl chloride)
British Library Electronic Table of Contents (United Kingdom)
Phonon relaxation and internal friction in kaolin-and bentonite-filled PVC composites are studied. By varying the temperature and/or content of the ultrafine mineral filler in the PVC, one can control the contribution from phonon viscosity, damping force, and the effect of viscosity into the energy dissipation of ultrasonic oscillations in the MHz frequency interval. The dynamic character of the measurements makes it possible to differentiate between relaxation phenomena in the composites and to suggest methods for their controlled changes.
2010-01-01
A tube inspection device. Dispositif de controle de tubes
Energy Technology Data Exchange (ETDEWEB)
The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).
1993-05-07
FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
Reactor poolside high-resolution fuel rod gamma scanning system
International Nuclear Information System (INIS)
(1981). United States Blair, TR Exxon Nucl, Richland, WA 99352
Nondestructive techniques for the control of conditioned radioactive wastes
International Nuclear Information System (INIS)
The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.
2005-09-01
The influence of material configuration and impact parameters on the damage tolerance characteristics of sandwich composites comprised of carbon-epoxy woven fabric facesheets and Nomex honeycomb cores was investigated using empirically based response surfaces. A series of carefully selected tests were used to isolate the coupled influence of various combinations of the number of facesheet plies, core density, core thickness, impact energy, impactor diameter, and impact velocity on the damage formation and residual strength degradation due to normal impact. The ranges of selected material parameters were typical of those found in common aircraft applications. The diameter of the planar damage area associated with Through Transmission Ultrasonic C-scan measurements and the peak residual facesheet indentation depth were used to describe the extent of internal and detectable surface damage, respectively. Standard analysis of variance techniques ...
2003-01-01
Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins
International Nuclear Information System (INIS)
A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.
International Nuclear Information System (INIS)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
1999-08-22
Energy Technology Data Exchange (ETDEWEB)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
1999-08-01
Gamma scanning of FBTR fuel pins
International Nuclear Information System (INIS)
This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.
Energy Technology Data Exchange (ETDEWEB)
In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet ...
1999-12-01
Inspection of PFR steam generators
International Nuclear Information System (INIS)
The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).
1976-03-09
Energy Technology Data Exchange (ETDEWEB)
Kawasaki Steel started the construction of an automatic steel strip coil transportation system in the 1980's. Presently, most of the in-plant transportation of hot-rolled or cold-rolled coils are automated. For establishing the automatic transportation, there were developed various technologies, such as, the optimum handling technology using artificial intelligence, the technology of preventing additional piling of coils on existing coils by using an ultrasonic wave and a laser beam. Through the improvements of these technologies, a full-automated transportation system has been achieved and the system has contributed substantially toward product quality assurance and cost reduction. This paper gives the changes in the automation technology of coil transportation in the automation of No. 3 finishing hot rolling mill, now having the latest automatic system, in Chiba Works. ...
1999-12-01
International Nuclear Information System (INIS)
English 1993 p. 161-163 China Zhu Rongbao Yang Liucheng Zhang
Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system
International Nuclear Information System (INIS)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
Energy Technology Data Exchange (ETDEWEB)
This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.
1983-01-01
Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends
Energy Technology Data Exchange (ETDEWEB)
A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second ...
2006-07-01
Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends
International Nuclear Information System (INIS)
A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second ...
2005-11-20
Nitrogen doping into titanium dioxide by the sol?gel method using nitric acid
British Library Electronic Table of Contents (United Kingdom)
N-doped TiO2 has been prepared by use of sol?gel systems containing titanium alkoxide, with nitric acid as the nitrogen source. The time needed for gelation of the systems was drastically reduced by ultrasonic irradiation. The peaks assigned to the nitrate and nitrous ions were observed by FT-IR measurement during the sol?gel reaction. The N-doping was confirmed by the observation of N?O peaks in the XPS spectrum of the sample heated at 400??C. The nitrate ion acted as an oxidizer of the ethanol solvent and titanium species. The TiO2 became doped with nitrogen oxide species as a result of reduction of nitrate ion incorporated into the dried gel samples. These results indicated that the added nitric acid was reduced during the sol?gel transition and heating process, and the resulting NO spe...
2011-01-01
International Nuclear Information System (INIS)
The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.
1989-09-10
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
International Nuclear Information System (INIS)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the ...
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the ...
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a lubrication control ...
1999-03-01
Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning
International Nuclear Information System (INIS)
The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).
Ultrasonic Acoustic Emissions from the Sapwood of Cedar and Hemlock 1
UK PubMed Central (United Kingdom)
Measurements are reported of ultrasonic acoustic emissions (AEs) measured from sapwood samples of Thuja occidentalis L. and Tsuga canadensis (L.) Carr. during air dehydration....Full Text Available
1984-08-01
Ultrasonic enhancement of heat transfer on narrow surface
Energy Technology Data Exchange (ETDEWEB)
Ultrasonic enhancement of heat transfer on a narrow surface was measured by changing the width of the surface from 8 to 0.1 mm. Ultrasonic power of 600 W with a frequency of 40 kHz was used. Heat transfer on the narrow surface without ultrasonic vibration was correlated by the experimental equation for a thin wire. The cavitation intensity was measured by the cavitation erosion loss of an aluminum foil of 15 [mu]m thickness. The effects of acoustic streaming and cavitation were separated by this measurement. Heat transfer by acoustic streaming was predicted through forced convection. Enhancement by cavitation was explained by the turbulence thermal conductivity of the microjets.
1994-06-01
Evaluation of ultrasonic indications in steam turbine rotors by fracture mechanics analysis
International Nuclear Information System (INIS)
The report summarizes ten years of experience in the analysis and evaluation of ultrasonic testing data measured in turbine and generator rotors. Apart from the information on type, position, size and distribution of flaws, the expert knowledge achieved in an interpretation of ultrasonic signals yields further insight, as e.g.: - Confirmation of assumptions taken as a basis for fracture-mechanical analysis of these flaws with regard to crack initiation and crack growth under low-cycle fatigue conditions (O=0.7-1 Rp 0.2, N<25.000 growth in length); - enhanced information on a correlation of ultrasonic testing data with the real flaw size. (orig.).
1990-10-04
Ultrasonic piezoelectric transducer that forms a specified directivity pattern
Energy Technology Data Exchange (ETDEWEB)
Methods of designing ultrasonic piezoelectric transducers in accord with a specified directivity pattern are analyzed and general formulas are presented for the design problem. As an example, the pressure distribution on the working surface of a circular piezoelectric transducer is determined that is capable of forming a narrow weakly divergent beam. Experimental results are presented with respected to ultrasonic fields that support the theoretical conclusions.
1989-03-01
Evaluation of phased array UT conditions using ultrasonic visualization technique
International Nuclear Information System (INIS)
Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)
2008-07-01
Effect of ultrasonic waves on boiling heat transfer. 2
International Nuclear Information System (INIS)
This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).
1993-05-01
Effect of ultrasonic waves on boiling heat transfer
Energy Technology Data Exchange (ETDEWEB)
This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).
1993-07-01
Effect of ultrasonic energy on Mn-Zn ferrite powder behavior
Energy Technology Data Exchange (ETDEWEB)
Effect of ultrasonic-wave irradiation on the Mn-Zn ferrite powder suspension prepared by solid-state reaction and alcoholic dehydration methods was investigated. Size, distribution, and morphology of the powders prepared at different temperatures were examined, as a function of irradiation time. It was observed that the powders were reduced in size by ultrasonic energy through distinct routes. 8 refs., 7 figs., 1 tab.
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
The objective of the inspection qualification is to ensure that applied non-destructive methods (NDT) have the required performance. The approach of the qualification process is systematic and carefully documented and therefore some new requirements can be seen concerning the composition of the documentation. There are also new document types, that only application of the inspection qualification requires. The most important of these is the technical justification, that includes the documented evidences concerning the performance of the inspection system. This publication includes two reports: 'Compilation of the inspection procedure' and 'Essential/influential parameters in NDT qualification'. The former of these discusses the issues to be considered in an inspection procedure especially from the point of view of the mechanised ultrasonic testing. The later report explains the parameters formulated to ...
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI disorders.
2009-05-15
Analysis by mass spectroscope device provided with ion source of induced plasma
International Nuclear Information System (INIS)
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.
Development of heavy-ion irradiation technique for single-event in semiconductor devices
Energy Technology Data Exchange (ETDEWEB)
Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)
1997-03-01
Beam position monitor readout and control in the SLC linac
Energy Technology Data Exchange (ETDEWEB)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
1985-04-01
Energy Technology Data Exchange (ETDEWEB)
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The ...
1995-08-01
Performance of a modified two-dimensional gamma scan system in spent fuel pin studies
International Nuclear Information System (INIS)
This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified ...
1999-11-01
International Nuclear Information System (INIS)
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...
Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot
UK PubMed Central (United Kingdom)
There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available
International Nuclear Information System (INIS)
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)
2001-09-01
Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber
Energy Technology Data Exchange (ETDEWEB)
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as ...
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot ...
2007-07-01
Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring
Energy Technology Data Exchange (ETDEWEB)
This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' ...
2005-12-15
Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy
International Nuclear Information System (INIS)
The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is ...
2009-10-12
International Nuclear Information System (INIS)
Glasses in the system (95-x) [0.25 Na2O-0.75 B2O3]-x P2O5-5 Fe2O3 (0?x?15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P2O5 on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P2O5. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P2O5 content as a second network former. These results are interpreted in terms of the replacement of the diborate units with B-O-B bridges by phosphate units with ...
2009-06-01
International Nuclear Information System (INIS)
Glasses in the system (1 - x) [29Na2O- 4Al2O3- 67B2O3]- xZnO (0 ? x ? 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N4 values (fraction of tetrahedral coordinated boron atoms), and substitution of longer bond lengths of Zn-O in place of ...
2009-05-05
An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for ...
2010-07-19
In this paper, we prepared a novel cationic self-assembled micelle from poly(epsilon-caprolactone)-poly(ethyl glycol)-poly(epsilon-caprolactone) grafted polyethyleneimine (PCEC-g-PEI). The PCEC-g-PEI micelles, formed by self-assembly method, had mean particle size of ca. 82 nm and zeta potential of +22.5 mV at 37 degrees C, and could efficiently transfer pGFP into HEK293 cells in vitro. Meanwhile, as a model hydrophobic chemotherapeutic drug, honokiol was loaded into PCEC-g-PEI micelles by direct dissolution method assisted by ultrasonication. The honokiol loaded cationic PCEC-g-PEI micelles could effectively adsorb DNA onto its surface, while it could release honokiol in an extended period in vitro. This study demonstrated a novel DNA and hydrophobic chemotherapeutic drug co-delivery system. PMID:21121283
2010-12-01
Prestin and high frequency hearing in mammals
UK PubMed Central (United Kingdom)
Recent evidence indicates that the evolution of ultrasonic hearing in echolocating bats and cetaceans has involved adaptive amino acid replacements in the cochlear gene prestin. A substantial...Full Text Available
2011-03-01
Intravesical Prostatic Protrusion in Men in Olmsted County, Minnesota
UK PubMed Central (United Kingdom)
PurposeUltrasonically measured intravesical prostatic protrusion may be a promising noninvasive method of assessing bladder outlet obstruction. Previous investigations...Full Text Available
2009-12-01
Automated NDT for large diameter tubular products
International Nuclear Information System (INIS)
Ultrasonic and eddy-current techniques are used to automatically examine large diameter tubular products during their production for defective areas and out-of-tolerance conditions.
1976-09-06
A Study on TOFD Inspection Using Phased Array Ultrasonic Technique
Energy Technology Data Exchange (ETDEWEB)
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure ...
2005-08-15
Development and application of a gamma scanning system for LLW and MLW packages
International Nuclear Information System (INIS)
The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.
1993-09-05
A Clinical Study on the Value of a Scoring System of the Scanning Images in Liver Cirrhosis
International Nuclear Information System (INIS)
Although the radioisotope liver scan has primarily been of use in the detection of the intra-hepatic space occupying lesions, there has been an increasing awareness of its use in evaluation of liver function. In this study, the degree of hepatomegaly, changes in shape and mottling radiodensity on each lobe and splenic visualization in the liver scans done with colloidal radiogold were numerically expressed as scores under the arbitrary standard in 210 patients with liver cirrhosis. The clinical value of this scoring system was studied with special regards to the correlation between the radiogold hepatic uptake half time and conventional liver function tests. Following were the results; 1) The normal scan appeared in 6.7% of 210 patients with liver cirrhosis. 2) The colloidal radiogold hepatic uptake half time was abnormally and progressively prolonged in parallel to severity of hepatocellular ...
1970-09-01
Energy Technology Data Exchange (ETDEWEB)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
No living analogue exists for the hypothetical early hominid hard/tough-seed, coarse-root-eating, and bone-crushing masticatory adaptation. To investigate possible microdamage/microwear to dental enamel caused by such usage, puncture-crushing experiments were carried out on single human teeth, using an Instron compression apparatus on the following six test materials: Makapansgat Limeworks chert (e.g., taphonomy), fresh steer longbone, mongongo nuts, Grewia berries, Carob beans, and wild-onion bulbs. Pairs of extracted unworn third molars were utilized, with one tooth acting as the control. The teeth were mounted, ultrasonically cleaned, and two-stage replicas made with a vinyl polysiloxane elastomer and araldite epoxy resin. After Instron loading and materials failure (1.2-395.0 kg) the test items and the crowns were prepared for comparison with scanning electron microscopy and dispersive x-ray elemental analysis and mapping. The results ...
1982-03-01
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
Scanning Electron Microscope Examination of Cotton Linters ...
... TECHNICAL REPORT ARBRL-TR-02476 SCANNING ELECTRON MICROSCOPE ... SCANNING ELECTRON MICROSCOPE EXAMINATION OF ...
1983-03-01
Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998
Energy Technology Data Exchange (ETDEWEB)
Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout that were investigated include bleeding, shrinkage, bond ...
1998-11-01
Energy Technology Data Exchange (ETDEWEB)
We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).
1995-12-31
Physics through the 1990s: scientific interfaces and technological applications
Energy Technology Data Exchange (ETDEWEB)
The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and many chapters contain recommendations ...
1986-01-01
International Nuclear Information System (INIS)
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...
2003-08-07
3-dimensional observations of atmospheric variables during the field campaign COPS
Energy Technology Data Exchange (ETDEWEB)
The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman ...
2008-05-01
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.
2003-05-01
A mobile gamma scanning system for detecting radiation anomalies
Energy Technology Data Exchange (ETDEWEB)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
1983-09-01
A mobile gamma scanning system for detecting radiation anomalies
International Nuclear Information System (INIS)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
Stress measurement and bolt tensioning by ultrasonic methods
International Nuclear Information System (INIS)
In the past decade, a new technique has been developed for measuring tensile stresses in solids. This ultrasonic technique has been used thus far primarily for measuring fastener tension. The precision of measurement is routinely to 2-3% and, with special care, to approx. 1%. The method is insensitive to the frictional losses which plague tensioning by torque wrench. Though the approach is relatively new, it promises a wide range of applicability.
1980-01-01
Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials
International Nuclear Information System (INIS)
It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.
2007-12-17
Energy Technology Data Exchange (ETDEWEB)
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate ...
2006-07-01
Performance characterization of a volumetric breast ultrasound scanner
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good ...
2007-03-01
Recent developments and applications for the University of Texas thermal neutron imaging facility
Energy Technology Data Exchange (ETDEWEB)
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work ...
2001-07-01
FCR (Fuji Computed Radiography) in neurosurgery
Energy Technology Data Exchange (ETDEWEB)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
1988-08-01
FCR (Fuji Computed Radiography) in neurosurgery
International Nuclear Information System (INIS)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
1988-01-01
Finite element analysis of a scanning x-ray microscope micropositioning stage
Energy Technology Data Exchange (ETDEWEB)
A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.
1992-01-01
International Nuclear Information System (INIS)
Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)
1998-10-30
For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817
1999-03-20
A novel gamma scanning system for on-line diagnostic inspection of industrial process columns
International Nuclear Information System (INIS)
A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)
Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring
International Nuclear Information System (INIS)
A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.
Thermal NDE method for thermal spray coatings
Energy Technology Data Exchange (ETDEWEB)
This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.
1982-01-01
International Nuclear Information System (INIS)
Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)
1999-10-26
Personal computers restructuring tomorrow's nets
Energy Technology Data Exchange (ETDEWEB)
Discusses alternative futures for distributing future personal computers, via data communications networks. The author scans and extrapolates some of the advances for impacting the emerging future of information utilities now sprouting up thoroughout the world. In particular he looks at the future of personal computers in the field of artificial intelligence,, for expert knowledge-based systems.
1982-01-01
Micromachining using focused ion beams
Energy Technology Data Exchange (ETDEWEB)
Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)
1994-11-16
Development of Guide System for a Reactor Head Maintenance Robot
Energy Technology Data Exchange (ETDEWEB)
The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address CRD nozzle inspection and repair issues. ...
2005-07-01
A statistical pattern recognition paradigm for structural health monitoring
Energy Technology Data Exchange (ETDEWEB)
The process of implementing a damage detection strategy for aerospace, civil and mechanical engineering infrastructure is referred to as structural health monitoring (SHM). Here damage is defined as changes to the material and/or geometric properties of these systems, including changes to the boundary conditions and system connectivity, which adversely affect the system's current or future performance. Our approach is to address the SHM problem in the context of a statistical pattern recognition paradigm (Farrar, Nix and Doebling, 2001). In this paradigm, the process can be broken down into four parts: (1) Operational Evaluation, (2) Data Acquisition, (3) Feature Extraction, and (4) Statistical Model Development for Feature Discrimination. When one attempts to apply this paradigm to data from 'real-world' structures, it quickly becomes apparent that data cleansing, normalization, fusion and ...
2004-01-01
Focused ion beam sculpting curved shapes.
Energy Technology Data Exchange (ETDEWEB)
A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.
2005-02-01
Extracellular matrix of plant callus tissue visualized by ESEM and SEM
British Library Electronic Table of Contents (United Kingdom)
Actinidia deliciosa endosperm-derived callus culture is stable over a long period of culture. This system was used to investigate the ultrastructure of extracellular matrix occurring in morphogenic tissue. Specimens were prepared by different biological techniques (chemical fixation, liquid nitrogen fixation, glycerol substitution, critical-point drying, lyophilization) and observed by scanning electron microscopy (SEM). Fresh and wet samples were analyzed with the use of environmental scanning electron microscopy (ESEM). Extracellular matrix was observed on the surface of cell clusters as a membranous layer or reticulated network, shrunken or wrinkled, depending on the procedure. Generally, shrunken membranous layers with a globular appearance and fibrils were noted after critical-point d...
2010-01-01
National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware
Energy Technology Data Exchange (ETDEWEB)
When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, ...
2001-07-27
UK PubMed Central (United Kingdom)
An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available
1984-04-01
Selective imaging of adherent targeted ultrasound contrast agents
UK PubMed Central (United Kingdom)
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
2007-04-21
In service inspection for steam generator tubes
International Nuclear Information System (INIS)
In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.
1987-11-24
Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools
Energy Technology Data Exchange (ETDEWEB)
Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.
1997-10-01
International Nuclear Information System (INIS)
We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.
1988-09-18
Modification of SGS system for application to various sized drums
Energy Technology Data Exchange (ETDEWEB)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the ...
2005-11-15
Modification of SGS system for application to various sized drums
International Nuclear Information System (INIS)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % ...
2005-11-01
International Nuclear Information System (INIS)
At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)
2005-04-01
Environmental Research Database
ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...
1996-01-31
Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis
Energy Technology Data Exchange (ETDEWEB)
A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.
2003-01-15
Energy Technology Data Exchange (ETDEWEB)
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels ...
1995-07-01
International Nuclear Information System (INIS)
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are ...
1346-01-01
Energy Technology Data Exchange (ETDEWEB)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...
2003-10-01
International Nuclear Information System (INIS)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma ...
2003-10-01
Energy Technology Data Exchange (ETDEWEB)
There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between the pressure tube channels is less than 100 mm and pipes in feederpipe support area ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
Glasses in the system (95-x) [0.25 Na{sub 2}O-0.75 B{sub 2}O{sub 3}]-x P{sub 2}O{sub 5}-5 Fe{sub 2}O{sub 3} (0<=x<=15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P{sub 2}O{sub 5} on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P{sub 2}O{sub 5}. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P{sub 2}O{sub 5} content as a second network former. These results are ...
2009-06-01
Energy Technology Data Exchange (ETDEWEB)
Glasses in the system (1 - x) [29Na{sub 2}O- 4Al{sub 2}O{sub 3}- 67B{sub 2}O{sub 3}]- xZnO (0 {<=} x {<=} 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N{sub 4} values (fraction of tetrahedral coordinated boron atoms), and ...
2009-05-05
A bright field scanning transmission electron microscope (STEM ...
A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental ...
2008-10-01
International Nuclear Information System (INIS)
Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median MRI slice was rated ...
2007-02-01
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation ...
Circumsolar radiation telescope
Energy Technology Data Exchange (ETDEWEB)
A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of ...
1980-01-01
International Nuclear Information System (INIS)
The gliding modes of a duplex Ti-6Al-4V titanium alloy were investigated through in situ (scanning electron microscopy) tensile tests. A method based on electron back-scattering diffraction (EBSD) measurements was used to identify activated slip systems. The approach applied to a large number of grains allowed a statistical analysis of the nature (basal, prismatic, pyramidal) and distribution of the slip systems according to the crystallographic texture. A discussion concerning the pertinence of Schmid's law to explain the occurrence and succession of slip events is then proposed. The domain in favor of each type of slip system is finally presented by using inverse pole figures mapped with Schmid's factor iso-curves.
2005-02-01
A microcontroller-based data-acquisition system for meteorological station monitoring
International Nuclear Information System (INIS)
This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
The impingement of a fluid jet onto a surface has broad applications across many industries. Within the UK nuclear industry, during the final stages of fuel reprocessing, impinging fluid jets are utilised to mobilise settled sludge material within storage tanks and ponds in preparation for transfer and ultimate immobilisation through vitrification. Despite the extensive applications of impinging jets within the nuclear and other industries, the study of two-phase, solid loaded, impinging jets is limited, and generally restricted to computational modelling. Surprisingly, very little fundamental understanding of the turbulence structure within such fluid flows through experimental investigation is found within the literature. The physical modelling of impinging jet systems could successfully serve to aid computer model validation, determine operating requirements, evaluate plant throughput requirements, optimise process operations and support design. Within this ...
2008-07-01
On the development of the METAR family of inspection tools
Energy Technology Data Exchange (ETDEWEB)
Since 1998, Hydro Quebec Research Centre (IREQ), in collaboration with Gentilly-2, has been working on the development of inspection devices for the feeder tubes of CANDU power plants. The first tool to come out of this work was the Metar bracelet, now used throughout the CANDU utilities, consisting of 14 ultrasonic probes held in place in a rigid bracelet to measure the thickness of the pipes and moved around manually along the pipe. Following the success of the Metar, a motorized version, i.e. the Crawler, has been developed to inspect beyond the operator arm's reach to access hard to reach place or further down the pipes in the reactor. This new system has been tested at 3 different stations and will be commercially available soon. Finally, the same technology was used to develop a motorized 2-axis crack detection device to answer new concerns about the feeder. Other configurations, depending on the demands from the industry, could ...
2003-07-01
Evaluation of the compressive mechanical properties of endoluminal metal stents.
The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of the beStent, the Crown and the Palmaz-Schatz stent (PS153-series) were comparable. The spiral articulated Palmaz-Schatz stent showed twice the ...
1998-06-01
Temperature measurements via narrow line laser absorption of carbon dioxide
Energy Technology Data Exchange (ETDEWEB)
Theoretical development for temperature measurements via narrow line, infrared absorption of carbon dioxide (CO{sub 2}) is presented. The proposed technique is based on rapid-scanning of two adjacent absorption line shapes. Spectroscopic considerations for sensitivity to temperature measurements are discussed. Several line pairs are evaluated, and the R(58) and R(60) transitions of the (00{sup 0}1){l_arrow}(00{sup 0}0) band are suggested for use in high temperature measurements for combustion systems.
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.
2010-07-01
Pitting corrosion of nickel base alloys in halide media
International Nuclear Information System (INIS)
A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.
1988-03-06
Mineral analysis in experimental corneal scars. An EDAX study
Energy Technology Data Exchange (ETDEWEB)
Central penetrating excisional wounds were made in the corneas of 12 rabbits and 10 trout. The scar tissue and the surrounding cornea were compared using a new method for assessing inorganic elements in the cornea: the scanning electron microscopy and energy dispersive analysis of x-ray (EDAX). Semiquantitative determination of inorganic elements within the range of atomic numbers 9-93 in the periodic system was performed, comparing the relative concentration of those elements in the scar tissue to the surrounding cornea. Results showed that calcium was the only element higher in the healing wound than in the surrounding cornea.
1988-01-01
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design ...
2007-08-21
Development of a rapid extraction procedure for speciation of arsenic in chicken meat
Energy Technology Data Exchange (ETDEWEB)
A rapid extraction procedure has been developed for speciation of arsenic in chicken tissue. Water, methanol-water (1:1), and methanol-chloroform (1:1) were tested as extraction media. Individual use of an ultrasonic bath, a microwave oven, or an ultrasonic probe was not sufficient for quantitative recovery of As(III), dimethylarsinate, monomethylarsonate, As(V), and arsenobetaine in spiked samples of chicken tissue. A new extraction procedure using a methanol-water mixture and a microwave oven then an ultrasonic probe enabled extraction of the arsenic species in 7 min with efficiencies ranging from 80 to 100%. HPLC-UV-HG-AFS was used for the determinations. The extraction procedure was 100% efficient when applied to real samples of chicken tissue. AsB (48{+-}5 {mu}g As kg {sup -1}) and one containing-arsenic feed additive, Nitarsone (227{+-}5 {mu}g As kg {sup -1}) were detected. (orig.)
2006-08-15
Energy Technology Data Exchange (ETDEWEB)
'The primary objective of this research project is to acquire a deeper fundamental knowledge of acoustic cavitation and cavitation chemistry, and in doing so, to ascertain how ultrasonic irradiation can be more effectively applied to environmental problems. Four on-going projects will be described in this progress report, The first project is the destruction of carbofuran in a Near-Field Acoustical Processor (NAP), and the hydrodynamic characterization of the reactor. The second project is a comprehensive study of how ultrasonic frequency influences sonochemical reaction rates; the substrate it, the preliminary portion of this study has been hydrogen peroxide formation. The third project in progress is destruction of four polychlorinated biphenyls at 20 kHz. Work so far has been at 20 kHz, but the most significant portion of this project will involve a multi-frequency (ultrasonic frequency) study. Finally, the ...
1997-01-01
Quantitative non-destructive evaluation of high-temperature superconducting materials
Energy Technology Data Exchange (ETDEWEB)
Even though the currently intensive research efforts on high- temperature superconducting materials have not yet converged on a well specified practical material, the indications are that such a material may be quite brittle, anisotropic, and may contain many flaws such as microcracks and voids at grain boundaries. Consequently, practical applications of high temperature superconducting materials will require a very careful strength analysis based on fracture mechanics considerations. Because of the high sensitivity of the strength of such materials to the presence of defects, methods of quantitative non-destructive evaluation may be expected to play an important role in strength determinations. This proposal is concerned with the use of ultrasonic methods to detect and characterize isolated cracks, clusters of microcracks and microcracks distributed throughout the material. Particular attention has been, and will continue to be devoted to relating ...
1991-06-14
Energy Technology Data Exchange (ETDEWEB)
New Non Destructive Testing techniques are currently being developed for the inspection of two groups of components in the FA3 EPR nuclear reactor at Flamanville. The first group of components to be controlled is constituted by the welds of the (89) rod cluster control assemblies' containment; two control types are to be used: an ultrasonic technique (UT) evaluation from the outside of the flange-casing weld, and an ET control from the inside of the three other welds. The second group of components is formed by the 44 welded joints of the primary circuit, which will be inspected through ultrasonic testing. Details of the components, control devices and sensors are given and some test results are presented
2009-07-01
Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction
International Nuclear Information System (INIS)
An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.
2005-04-09
Extraction of biologic particles by pumping effect in a p-shaped ultrasonic actuator
British Library Electronic Table of Contents (United Kingdom)
This paper presents a new method of extracting biologic particles from a mixture of particles. The method is based on the pumping effect in a p-shaped ultrasonic actuator, which has a gap between its two vibrating metal plates. An adhesive tape is placed at a proper position in the gap. Due to the pumping effect which is induced by the sound field in the gap, the particles with smaller mass and radius in the mixture can be pumped up to reach the adhesive tape; while the ones with larger mass cannot. Therefore, the particles with smaller mass and radius can be extracted from the mixture. A theoretical model which can well explain the operation principle and experimental phenomena is developed. By the experimental results and the theoretical analyses based on the model, the validity of the m...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Ultrasonic gold and aluminum wire wedge bonding are widely used for electrical and signal interconnections of the integrated circuit chip packages. In this paper, based on the metallurgical theories and thermal aging test methods, the long-term thermal reliabilities of gold and aluminum wire wedge bonding on aluminum and Au/Ni/Cu pads, were investigated, respectively. At 200degreeC, the Au/Al bond interfaces evolved little when the storage time was less than 48h; with the aging time increasing, the interfacial intermetallic compounds (IMC) grew up from the pad (vertical growth); the primary compounds were Au5Al2 near the bond toe and heel, and Au2Al at the periphery. Then, the thickness of IMC was unchanged, and extended horizontally (lateral growth), Au5Al2 transformed into more stable Au...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Automatic ultrasonic testing is presented as a method for recurrent inspections of pressure gas vessels, from validation to practical testing to customised test applications. National and international regulations and standards are presented along with related implementation problems. [German] Es wird die automatisierte Ultraschallpruefung im Bereich der wiederkehrenden Pruefung von Druckgasbehaeltern, als Alternative zur herkoemmlichen, klassischen Wasserdruckpruefung, vorgestellt. Von der Validierung ueber die praktische Erprobung bis hin zur kundenspezifisch entwickelten Pruefapplikation. Es werden die Anforderungen aus nationalen und internationalen Vorschriften und Normen sowie die damit zusammenhaengenden Umsetzungsprobleme behandelt.
2005-07-01
International Nuclear Information System (INIS)
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas ...
2007-09-21
Motion compensation with a scanned ion beam: a technical feasibility study
UK PubMed Central (United Kingdom)
BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target...Full Text Available
International Nuclear Information System (INIS)
Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion tests.
2011-02-01
British Library Electronic Table of Contents (United Kingdom)
Flue gas desulfurization systems (FGDs) are operated in severely corrosive environments that cause sulfuric acid dew-point corrosion. The corrosion behavior of low-alloy steels was tested using electrochemical techniques (electrochemical impedance spectroscopy, potentiodynamic tests, potentiostatic tests), and the corrosion products were analyzed by scanning electron microscopy and X-ray photoelectron spectroscopy. The electrochemical results showed that alloying W with small amounts of Sb, Cu, and Co improves the corrosion resistance of steels. The results of surface analyses showed that the surface of the steels alloyed with W consisted of W oxides and higher amounts of Sb and Cu oxides. This suggests that the addition of W promotes the formation of a protective WO3 film, in addition to ...
2011-01-01
Development of high-field STM for 18 T cryocooled superconducting magnet
International Nuclear Information System (INIS)
To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.
2009-02-01
Design and control of six degree-of-freedom active vibration isolation table.
A six-axis active vibration isolation system (AVIS) is designed by using the direct driven guide and ball contact mechanisms in order to have no cross-coupling between actuators. The point contact configuration gives an advantage of having an easy assembly of eight voice coil actuators to an upper and a base plate. A voice coil actuator is used since it can provide a large displacement and sufficient bandwidth required for vibration control. The AVIS is controlled considering the effect of flexible vibration mode in the upper plate and velocity sensor dynamics. A loop shaping technique and phase margin condition are applied to design a vibration controller. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system. The scanning profiles of the specimen are compared together by using the atomic force microscope. The robustness of the AVIS is ...
2010-03-01
Automated bead-positioning system for measuring impedances of R-F cavity modes
Energy Technology Data Exchange (ETDEWEB)
We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.
1993-05-01
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral formation in this ...
2011-05-05
Energy Technology Data Exchange (ETDEWEB)
One- and two-dimensional long-period superstructures (LPS), based on the L1{sub 2} substructure, are systematically investigated for the noble metal-palladium alloys Cu-Pd, Ag-Pd and Au-Pd with first-principles methods. Notwithstanding the fact that the experimental phase diagrams of these systems yield totally different features, quite similar behaviour with respect to formation of low temperature ordered LPS-phases (Cu{sub 3}Pd: LPS 3, Ag{sub 3}Pd: LPS 3, Au{sub 3}Pd: LPS 2; {l_brace}Cu, Au{r_brace}Pd{sub 3}: L1{sub 2}, AgPd{sub 3}: not a ground state) is predicted. As a lever between via LDA obtained formation enthalpies and a thorough ground state scan, the cluster expansion method in conjunction with a genetic algorithm provides adequate means for the extraction of effective interactions, which also allow for an enhanced ground state scan in the configurational space of LPS structures. As a result, the sequences and ...
2007-07-01
Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloy
International Nuclear Information System (INIS)
Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloys with 0#<=#x#<=#1 have been performed. The simulations are compared with measured channeling-angular scans for strained Si_0_._9_5Sn_0_._0_5 layers grown by molecular beam epitaxy (MBE). Agreement between simulated and measured angular scans can only be achieved if we assume a deviation of the crystal structure from the ideal one. This deviation can be attributed to a mosaic structure in the films and to an atomic-scale distortion of the crystal lattice due to an expected difference in the bond lengths between the Si-Si, Si-Sn and Sn-Sn atoms (such a difference in bond lengths has been observed in the epitaxial Si_1_-_xGe_x system). The contributions from both of these imperfections are estimated and discussed.
2000-04-01
MicroDiffraction in the Scanning Electron Microscope (SEM)
The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and ...
1997-12-31
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
Intrapartum FHR monitoring and neonatal CT brain scan
Energy Technology Data Exchange (ETDEWEB)
The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with ...
1982-12-01
Intrapartum FHR monitoring and neonatal CT brain scan
International Nuclear Information System (INIS)
The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and no ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
One bundle of Hanaro fuel irradiated up to 50%-burnup and cooled for 6 months was transported to IMEF for PIE, which has 6 elements. At first we measured the longitudinal distribution and the rotational distribution of several dominant peaks intensities from the bundle. After dismantling of the bundle we measured the longitudinal distribution of {sup 137}Cs and {sup 134}Cs peaks in each fuel element to see the burn-up feature. And finally we found out the relative number distribution of {sup 137}Cs and {sup 134}Cs for each detection point, which would be used for burn-up calculation. The relative detection efficiency of the scanning system was obtained experimentally by using the {sup 134}Cs peaks. We also checked up the azimuthal difference of peak intensity for each element, which are resulted about 2% of difference. These data will be used for the further analysis of Hanaro fuel performance evaluation. (author)
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...
1989-02-01
International Nuclear Information System (INIS)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...
1989-01-01
Detection of Second-Layer Corrosion in Aging Aircraft Fuselage
International Nuclear Information System (INIS)
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS ...
2006-12-01
Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" and one belongs to the ...
2007-01-01
Bone scanning in Ewing's sarcoma
International Nuclear Information System (INIS)
In eight patients with Ewing's sarcoma bone scans were performed using "9"9"mTc-MDP. This procedure rendered possible the diagnosis of clinically or radiologically silent metastases. (orig.).
This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to
2003-01-01
Self-assessment of current knowledge in nuclear medicine (second edition)
Energy Technology Data Exchange (ETDEWEB)
In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...
1981-01-01
New real-time MR image-guided surgical robotic system for minimally invasive precision surgery
Energy Technology Data Exchange (ETDEWEB)
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...
2008-04-15
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
2007-05-10
Radwaste Drum Assay Technology by Segmented Gamma Scanning System
Energy Technology Data Exchange (ETDEWEB)
Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential peak absorption, ...
2009-01-15
Radiations against tumors: a bit old-fashioned?; Rayonnements contre tumeurs: un rien demode?
Energy Technology Data Exchange (ETDEWEB)
The proton therapy gives an irradiation adapted to the shape and the depth of tumors ( eyes, head and neck) with a millimetric, even sub millimetric precision for the ophthalmological tumors. It is equally an excellent tool for the pediatrics tumors. For numerous treatments in France the proton therapy is associated to the photons treatments (x radiation). however, others physical treatments could modulate the medical offer, such thermal therapy or treatments by ultrasonic waves. (N.C.)
2004-09-01
University research group with research areas: * Land based and submersible autonomous robots, (UUVs: AUVs and ROVs); * Controllers, electronics, sensor design and fusion, motion control; * Guidance and navigation of underwater vehicles; * AI, neural networks, fuzzy logic, subsumption control, behaviour based control; * Optical fibre and ultrasonic sensors for proximal object detection; * Robot arm control, visual servoing; * Imaging sonar applications; * Simulator development: UUV simulator; imaging sonar simulator; Aircraft/flight simulator.
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
In addition to their use in high-speed ovens, microwaves are also finding applications in industrial manufacture, quality control and storage - anywhere where the high-frequency transmission or reflection properties of a material can be exploited. Microwaves are also being used in medical applications for the characterization of certain type of tumours. They are also being used in research into ultrasonic cavitation. (authors) 5 refs.
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The report investigates a number of joining techniques, i.e. isothermal solidification, ultrasonic welding, thermocompression, and glueing. (HW) [Deutsch] In diesem Vorhaben wurden verschiedene Verbindungstechniken untersucht: Isotherme Erstarrung; Ultraschall-Schweissen; Thermokompression; Leitkleben. (HW)
1992-09-01
An ultrasonic goniometer for surface stress measurement
An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.
1978-09-01
Radiometric measurement of temperature distributions in solar cavity receivers
Energy Technology Data Exchange (ETDEWEB)
An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...
1989-03-01
International Nuclear Information System (INIS)
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...
Is there still a place for bone scanning in Ewing's sarcoma: concise communication
International Nuclear Information System (INIS)
In this retrospective study, 28 cases of Ewing's sarcoma are reviewed for the onset of metastasis. Bone scans demonstrated bone metastasis in three out of 28 patients at presentation. Of the 22 patients free of metastases at presentation, ten subsequently developed bone metastases. In six of these patients, the bone scan was the earliest demonstrator of metastatic disease. Bone scans are recommended at presentation and periodically during follow-up.
... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...
The carbon fiber surface treatment and addition of PA6 on tensile properties of ABS composites
British Library Electronic Table of Contents (United Kingdom)
In this study acrylonitrile-butadiene-styrene (ABS) terpolymer was reinforced with HNO3-treated short carbon fibers (HCFs). The effects of HCF concentration on the tensile properties of the composites were examined. Increasing the HCF concentration in the ABS matrix from 10 wt% to 30 wt% resulted in improved tensile strength and tensile modulus. To obtain a strong interaction at the interface, polyamide-6 (PA6) at varying concentrations was introduced into the ABS/10 wt% HCF composite. The incorporation and increasing amount of PA6 in the composites increased tensile properties of the ABS/PA6/HCF systems due to the improved adhesion at the interface, which was confirmed by the ratio of tensile strength as an adhesion parameter. These results were also supported by scanning electron microgr...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The use of indigenous bacterial root endophytes with biocontrol activity against soil-borne phytopathogens is an environmentally-friendly and ecologically-efficient action within an integrated disease management framework. The earliest steps of olive root colonization by Pseudomonas fluorescens PICF7 and Pseudomonas putida PICP2, effective biocontrol agents (BCAs) against Verticillium wilt of olive (Olea europaea L.) caused by the fungus Verticillium dahliae Kleb., are here described. A gnotobiotic study system using in vitro propagated olive plants, differential fluorescent-protein tagging of bacteria, and confocal laser scanning microscopy analysis have been successfully used to examine olive roots?Pseudomonas spp. interactions at the single-cell level. In vivo simultaneous visualization...
2011-01-01
Range-resolved gas concentration measurements using tunable semiconductor lasers
British Library Electronic Table of Contents (United Kingdom)
A method for range-resolved gas sensing using path-integrated optical systems is presented. The method involves dividing an absorption path into several measurement segments and extracting the gas concentration in each segment from two path-integrated measurements. We implemented the method with tunable lasers (a 1389-nm VCSEL and a 10.9-?m pulsed quantum cascade laser) and a group of retro reflectors (RRs) distributed along absorption paths. Using a rotating mirror with the VCSEL configuration, we could scan a group of seven tape RRs spaced by 10?cm in ??9?ms to extract an H2O concentration profile. Reduced H2O concentrations were recorded in the segments purged with dry air. Hollow corner cube RRs were used in the quantum cascade laser configuration at distances up to 1.1?km from the las...
2008-01-01
Radiation risk in computerized tomography (CT)
Energy Technology Data Exchange (ETDEWEB)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...
1984-01-01
Radiation risk in computerized tomography (CT)
International Nuclear Information System (INIS)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...
1984-01-01
Radiation risk in computerized tomography (CT)
International Nuclear Information System (INIS)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...
British Library Electronic Table of Contents (United Kingdom)
The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The photocytotoxic effect of hypericin (Hyp) targeted by two different delivery techniques, namely, liposomes and anti-hepatocyte specific antigen (anti-HSA) was investigated. Optical absorption and steady-state fluorescence were used to analyze the conjugation of Hyp with anti-HSA model and to evaluate the encapsulation capacity and drug release in a liposome model. Particle size and thermal analysis of the prepared liposomes were performed using laser-light scattering and differential scanning calorimetry (DSC), respectively. Viability study of HepG2 cells exposed to Hyp in the two delivery systems, in the dark and following visible light irradiation, was performed in comparison to free Hyp. The intracellular uptake and localization of Hyp in HepG2 cells were analyzed by means of spectro...
2010-01-01
Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator
Energy Technology Data Exchange (ETDEWEB)
A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared with direct beam profile measurements.
2009-02-11
International Nuclear Information System (INIS)
A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (#approx#1x1 mm"2). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin.
2006-09-01
Morphology evolution of Ir-Nb-X (X = Hf, Ta, or Ti) ternary alloys
Energy Technology Data Exchange (ETDEWEB)
The microstructure evolution of nine samples from three Ir-base ternary systems, Ir-Nb-Hf, Ir-Nb-Ta, and Ir-Nb-Ti, was investigated by microstructure observation using scanning electron microscopy (SEM), composition map-analysis using electron probe microscopy analysis (EPMA), and phase determination using X-ray diffraction (XRD) patterns. The fcc/L1{sub 2} two-phase structure was detected in all the samples. Lattice misfits between fcc and L1{sub 2} phases were calculated. Ir-Nb-Ta and Ir-Nb-Ti alloys exhibited a microstructure quite similar to that of Ni-base superalloys, and the cuboidal L1{sub 2} precipitates in Ir-Nb-Ta and Ir-Nb-Ti alloys could maintain up to 1900 {sup o}C.
2007-01-31
British Library Electronic Table of Contents (United Kingdom)
Propanolol is a betablocker drug used in the treatment of arterial hypertension related diseases. In order to achieve an optimal performance of this drug it is important to consider the possible interactions of propanolol with plasma proteins. In this work, we have used several experimental techniques to characterise the effect of addition of the betablocker propanolol on the properties of bovine plasma fibrinogen (FB). Differential scanning calorimeter (DSC), circular dichroism (CD), dynamic light scattering (DLS), surface tension techniques and atomic force microscopy (AFM) measurements have been combined to carry out a detailed physicochemical and surface characterization of the mixed system. As a result, DSC measurements show that propranolol can play two opposite roles, either acting ...
2011-01-01
Focused ion beam preparation of inclined planes in semiconductor materials
International Nuclear Information System (INIS)
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
Electrochemical behaviour of multicomponent Zr-Ti-V-Mn-Cr-Ni alloys in alkaline solution
Energy Technology Data Exchange (ETDEWEB)
The effect of the composition of multicomponent Zr-Ti-V-Mn-Cr-Ni alloys on their hydrogen-storage capacity and on the rate of electrosorption/desorption hydrogen was investigated under potentiodynamics as well as single-pulse and long-term galvanostatic conditions. The main characteristics of alloys and alloy electrodes were determined by their structural analysis by means of X-ray diffraction and scanning electron microscope, by specific surface area test and by determination of the hydrogen absorption/desorption isotherms in the gas/solid phase system. It was found that only the alloys with a manganese content below a threshold could be used as electrode materials for Ni-MH batteries, whereas the modification of the electrode material by micro-encapsulation of alloy particles should limit the dissolution of manganese from the electrode material in a strong alkaline solution. (orig.)
1996-01-01
Effects of coolant chemistry on corrosion of 3003 aluminum alloy in automotive cooling system
British Library Electronic Table of Contents (United Kingdom)
In this work, effects of coolant chemistry, including concentrations of chloride ions and ethylene glycol and addition of various ions, on corrosion of 3003 Al alloy were investigated by electrochemical impedance spectroscopy measurements and scanning electron microscopy characterization. In chloride-free, ethylene glycol-water solution, a layer of Al-alcohol film is proposed to form on the electrode surface. With the increase of ethylene glycol concentration, more Al-alcohol film is formed, resulting in the increase in film resistance and charge-transfer resistance. In the presence of Cl- ions, they would be involved in the film formation, decreasing the stability of the film. In 50% ethylene glycol-water solution, the threshold value of Cl- concentration for pitting initiation is within ...
2010-01-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
1991-12-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
1991-01-01
Assessment of MCNP-4B code using measurement data of Wolsung nuclear power plant 2
International Nuclear Information System (INIS)
The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear power plant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.
2001-05-01
A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin
British Library Electronic Table of Contents (United Kingdom)
A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...
2008-01-01
Thermodynamics and stability of the mixed-conducting Sr-Fe-Co-O system.
Energy Technology Data Exchange (ETDEWEB)
Mixed-conducting Sr-Fe-Co oxides have potential applications in dense ceramic membranes for high-purity oxygen separation and/or methane conversion to produce syngas (CO + H{sub 2}), because of their combined high electronic/ionic conductivity and significant oxygen permeability. We studied the crystal structure and microstructure of the system in X-ray diffraction experiments and by using scanning electron microscopy, respectively. Thermogravimetric analysis was conducted on the SrFeCo{sub 0.5}O{sub x} sample in environments of various oxygen partial pressures (pO{sub 2}). Conductivity increased while weight decreased with increasing temperature. Activation energy decreased while conductivity increased with increasing pO{sub 2}. The pO{sub 2}-dependent conducting behavior of the SrFeCo{sub 0.5}O{sub x} system can be understood by considering the trivalent-to-divalent transition of transition-metal ions.
1999-04-28
MTX diagnostic and timing system for free-electron laser heating experiments
International Nuclear Information System (INIS)
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of ...
Fabrication of nanometer structures by means of a fine-focused ion beam
International Nuclear Information System (INIS)
Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal deposition is given. The layer quality is determined by Auger electron analysis which ...
2000-03-01
International Nuclear Information System (INIS)
The adherent magnetite film thickness, corrosion rate and the loose crud on the surface of carbon steel and other structural materials were evaluated by inserting the coupons in the two autoclaves connected to the two ends of the PHT systems of Indian PHWRs. This paper includes an analysis of the results obtained during the hot conditioning of TAPP-3 and 4, Kaiga-3 and 4, and RAPP-5. The system temperatures of 230 deg C to 260 deg C and the adherent magnetic thickness of 0.30 ?m to 0.75 ?m on the internal surface of carbon steel were achieved during the hot conditioning of these reactors. The time duration of termination of the hot conditioning ranged from 48 to 71 hours. The maximum magnetite film thickness of 0.75 ?m in 71 hours and temperature 260 deg C and a minimum thickness of 0.30 nm in 48 hours at 230 deg C were achieved during hot conditionings. The XRD analyses of hot conditioned carbon steel coupons showed that oxide film constitutes ...
2008-12-01
International Nuclear Information System (INIS)
Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations using Somatom Siemens Emotion scanner. Non-enhanced sections were obtained with 8 mm ...
2007-01-01
Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997
Energy Technology Data Exchange (ETDEWEB)
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform ...
1998-03-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...
2006-04-01
International Nuclear Information System (INIS)
The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The acoustic amplitude ...
"9"9"mTechnetium-heat damaged erythrocyte spleen scan
International Nuclear Information System (INIS)
"9"9"mTechnetium -heat damaged erythrocyte were used as spleen scanning agents in 12 patients from July, 1985 to April, 1986. We used this scan to evaluate situs inversus, asplenia, accessory spleen, hypersplenism, splenic infarction, tumor staging and evaluation of therapy, especially when the "9"9"mTc-tin colloid scans were not definite for diagnosis. The techniques applied to these scans were in vivo/in vitro-labeling method and heating-method to damage the erythrocytes. Liver-to-spleen uptake ratios were increased upto 100:1 and interference from the left lobe of the liver was eliminated. These scans were helpful to evaluate the spleen. (Author).
Time-of-Flight Measurements from Eddy Current Tests
Data fusion techniques are based on the premise that two or more carefully designed NDE tests are potentially capable of offering additional information concerning the test object relative to what can be garnered from a single test. However, information from a heterogeneous set of transducers cannot be fused unless the data is mapped onto a common `format'. The eddy current method cannot, for example, provide time-of-flight information that can be combined from estimates derived from ultrasonic tests. This paper presents a simple solution to address the problem by employing the so-called Q-transform to relate diffusive fields, such as those generated by eddy current probes, and propagating wave fields generated by ultrasonic NDT sensors. The paper illustrates how the distance between a defect and a source can be extracted from eddy current data generated using carefully selected excitation signals. Numerical results and comparisons with ...
2003-03-01
Energy Technology Data Exchange (ETDEWEB)
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...
1995-08-01
International Nuclear Information System (INIS)
Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the detectability of these probes. (author).
1991-08-01
A laser pyrolysis technique has been used to produce ultrafine particles of iron carbide with diameters ranging from 2 to 20 nm. Catalysis using iron carbide was investigated in the liquefaction of Wyodak subbituminous coal; yields were determined. A study was carried out to examine the possibility of using an ultrasonic extraction technique as a rapid method of product work-up of samples following pretreatment or liquefaction experiments. A similar study had shown that extraction of coal-derived products by an ultrasonic method was rapid and gave yields and product distributions comparable to those obtained by Soxhlet extraction. On another project, three different types of supported catalysts were used to test activity for the combined water-gas shift hydrogenation of a synthetic donor solvent. The three catalysts tested were: (1) Alumina supported NiMo catalyst-Shell 324m; (2) Bulk hydrous TiO NiMo catalyst; (3) Thin film hydrous TiO ...
1991-12-31
Energy Technology Data Exchange (ETDEWEB)
The project involved several studies of vesicles and micelles and their constituent surfactants. The primary objective of the project was an elucidation of factors involved in the stabilization and destabilization of vesicles and micelles. Work was performed on seven individual studies. Several different types of novel cleavable surfactants were synthesized, including systems with two chains and two head groups, and their aqueous micelles and vesicles were characterized by methods including dynamic laser light scattering (to give aggregate sizes) and differential scanning calorimetry (to give vesicle bilayer phase transition temperatures). A cleavable surfactant is stable under certain conditions but liable under other conditions with respect to cleavage to give nonsurfactant products and/or other surfactants with different properties. The destruction of several cleavable surfactant-derived aggregates was demonstrated, indicating that they have ...
1996-03-19
Phase diagram of the ternary system lauric acid-capric acid-naphthalene
Energy Technology Data Exchange (ETDEWEB)
The mixture of lauric acid and capric acid is a potential latent heat storage material. However, its eutectic melting temperature is quite high for low-temperature thermal energy storage. Addition of naphthalene is proposed. The ternary system lauric acid-capric acid-naphthalene has been investigated by differential scanning calorimetry (DSC), visual polythermal and chromatography of gases. The phase diagram is of an incongruent eutectic type. The eutectic mixture contains 18.4mol% lauric acid, 63.1mol% capric acid and 18.5mol% naphthalene and melts at 13.3{sup o}C. The peritectic mixture contains 32.4mol% lauric acid, 48.2mol% capric acid and 19.4mol% naphthalene and peritectic temperature of 16.2{sup o}C. The incongruent compound was analysed to be CH{sub 3}(CH{sub 2}){sub 10}COOH.CH{sub 3}(CH{sub 2}){sub 8}COOH. The melting temperature of the lauric acid-capric acid-naphthalene eutectic mixture makes it suitable for cooling applications.
2004-12-15
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)
2005-10-15
International Nuclear Information System (INIS)
Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...
Energy Technology Data Exchange (ETDEWEB)
The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel irradiated at Hanaro - PIE of ...
2002-12-01
International Nuclear Information System (INIS)
In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis sub-program was stated to determine the long-lived non-gamma emitting ...
Applications of a downhole programmable microprocessor for a geothermal borehole inspection tool
Energy Technology Data Exchange (ETDEWEB)
The high-temperature scanning borehole inspection system is currently being developed jointly by the Los Alamos National Laboratory (LANL) and Westfalische Berggewerkschaftskasse (WBK) of West Germany. The downhole instrument is a digital televiewer that utilized a microprocessor to digitize, process and transmit the acoustic information to the surface acquisition and control system. The primary operation of the downhole acoustic assembly uses a piezoelectric crystal acting as a receiver-transmitter which is mounted on the rotating head. The crystal emits a burst of acoustic energy that propagates through the borehole fluid with a portion of the energy reflected by the borehole wall back to the crystal. The time of travel and the amplitude of the reflected signal are conditioned by the microprocessor and transmitted along with other pertinent data to the surface data processing center. This instrument has been designed ...
1987-01-01
Nondestructive Technique Survey for Assessing Integrity of Composite Firing Vessel
Energy Technology Data Exchange (ETDEWEB)
The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.
2000-08-01
Nondestructive Detection Techniques of Garter Springs from CANDU Reactors
Energy Technology Data Exchange (ETDEWEB)
The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.
2004-04-15
Decontamination of Johnston Island Coral: a preliminary study
International Nuclear Information System (INIS)
A preliminary investigation was completed on the characterization and decontamination of coral samples from Johnston Island. These samples were found to contain individual particles (2 to 0.25 mm) of contaminated coral as well as a piece of contaminated magnetic metal. They ranged in activity from about 70 to 811 nCi Am-241. The decontamination methods investigated were froth flotation, ferrite treatment, attrition scrubbing, ultrasonic treatment and dry sieving. Dry sieving, the more effective technique, separated about 42 wt % of the coral into a decontaminated fraction. This fraction (>4 mm) contained about 0.5% of the total activity. 7 refs., 3 tabs.
Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983
During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.
1984-10-01
Energy Technology Data Exchange (ETDEWEB)
This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)
1998-12-15
Ultrasmall spot size scanning laser ophthalmoscopy
UK PubMed Central (United Kingdom)
An ultrasmall spot size scanning laser ophthalmoscope has been developed that employs an annular aberration-corrected incident beam to increase the effective numerical aperture of the eye thereby reducing...Full Text Available
Simple device for scanning image
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
2002-01-01
Role of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot
UK PubMed Central (United Kingdom)
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
2010-02-01
UK PubMed Central (United Kingdom)
Background:The purpose of the study was to evaluate vitreoretinal interface (VRI) alteration with a short-wavelength scanning laser ophthalmoscope (swSLO), the Nidek F-10, and compare...Full Text Available
2011-01-01
New Biomarkers Probing Depth of Cell Senescence Assessed by Laser Scanning Cytometry
UK PubMed Central (United Kingdom)
The imaging analytical capabilities of laser scanning cytometer (LSC) have been used to assess morphological features considered to be typical of the senescent phenotype. The characteristic “flattening”...Full Text Available
2010-11-01
Energy Technology Data Exchange (ETDEWEB)
Thirty-two patients with AIDS related complex (ARC) or acquired immunodeficiency syndrome (AIDS) underwent /sup 67/Ga scans as part of their evaluation. Three patterns of /sup 67/Ga biodistribution were found: lymph node uptake alone; diffuse pulmonary uptake; normal scan. Gallium-67 scans were useful in identifying clinically occult Pneumocystis carinii pneumonia in seven of 15 patients with ARC who were asymptomatic and had normal chest radiographs. Gallium scans are a useful ancillary procedure in the evaluation of patients with ARC or AIDS.
1987-07-01
Environmental scanning electron microscopy
Energy Technology Data Exchange (ETDEWEB)
The ElectroScan environmental scanning electron microscope (ESEM) is one of the most exciting new developments in the field of Electron Microscopy. The ESEM differs from conventional Scanning Electron Microscopes (SEM) by being able to examine materials including liquids and oils in their natural state with no prior sample preparation. Accessory equipment, cooling, heating and manipulating devices allow the manipulation of samples thus making it possible for the first time to image dynamic processes such as wetting, drying, absorption, corrosion, melting, crystallisation, curing and fracturing at high magnification. Papers concerning the historical development of the ESEM are given in a bibliography at the end of this paper. 24 refs., 18 figs.
1994-12-31
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
Energy Technology Data Exchange (ETDEWEB)
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those ...
1998-12-01
Inguino-scrotal hernia detection in the early phase of a bone scan
International Nuclear Information System (INIS)
A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd
1999-11-01
Brain and bone scans in primary Ewing's sarcoma of the petrous bone: case report
International Nuclear Information System (INIS)
The authors present a case in which primary Ewing's sarcoma of the right petrous pyramid in a 9-year-old girl showed no uptake on a /sup 99m/Tc-pertechnetate nuclide angiogram. Intense uptake was present on a /sup 99m/Tc-polyphosphate bone scan, but a static brain scan was only minimally abnormal. The diagnosis and treatment of Ewing's sarcoma are reviewed.
Energy Technology Data Exchange (ETDEWEB)
Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and sizing (single frequency technique with ...
1999-07-01
International Nuclear Information System (INIS)
A combined application of several microtechniques is presented and discussed with the Ti/TiO_2 and Zr/ZrO_2-systems as an example. All measurements were carried out on single grains of technical materials in order to detect and quantify the effect of substrate microstructure on the properties of anodic passive films formed potentiodynamically in 0.5 M H_2SO_4 (dU/dt = 20 mVs"-"1). Anisotropy-micro-ellipsometry (AME) was employed to determine the crystallographic orientation of the substrate grains along with passive film thickness and crystallinity in dependence on the anodization potential. Both the isotropic (amorphous) TiO_2- and the anisotropic (crystalline) ZrO_2-films exhibit a systematic dependence of film thickness on the grain orientation. Local LASER-scanning photocurrent measurements (#lambda#=257 nm) on the same grains likewise show a heterogeneity of the photoelectrochemical reactivity in all cases. This is quantitatively explained ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...
1991-12-01
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different ...
2007-03-15
Wood Plastic Composites (WPCs) have experienced a healthy growth during the last decade. However, improvement in properties is necessary to increase their utility for structural applications. The toughness of WPCs can be improved by creating a fine cellular structure while reducing the density. Extrusion processing is one of the most economical methods for profile formation. For our study, rectangular profiles were extruded using a twin-screw extrusion system with different grades of HDPE and with varying wood fibre and lubricant contents together with maleated polyethylene (MAPE) coupling agent to investigate their effects on WPC processing and mechanical properties. Work has been done to redesign the extrusion system setup to achieve smoother and stronger profiles. A guiding shaper, submerged in the water, has been designed to guide the material directly through water immediately after exiting the die; instead of passing it through a water ...
2010-01-01
International Nuclear Information System (INIS)
The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising "9"9"mTc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)
Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
2009-01-01
Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan
International Nuclear Information System (INIS)
Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal ...
2009-10-01
Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument
International Nuclear Information System (INIS)
Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, which can be attached ...
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned ...
2005-04-01
International Nuclear Information System (INIS)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned ...
2005-04-01
Structure and Function Evolution of Thiolate Monolayers on Gold
Energy Technology Data Exchange (ETDEWEB)
The use of n-alkanethiolate self-assembled monolayers on gold has blossomed in the past few years. These systems have functioned as models for common interfaces. Thiolate monolayers are ideal because they are easily modified before or after deposition. The works contained within this dissertation include interfacial characterization (inbred reflection absorption spectroscopy, ellipsometry, contact angle, scanning probe microscopy, and heterogeneous electron-transfer kinetics) and various modeling scenarios. The results of these characterizations present ground-breaking insights into the structure, function, and reproducible preparation of these monolayers. Surprisingly, three interfacial properties (electron-transfer, contact angle, and ellipsometry) were discovered to depend directly on the odd-even character of the monolayer components. Molecular modeling was utilized to investigate adlayer orientation, and suggests that these effects are ...
2006-05-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
Energy Technology Data Exchange (ETDEWEB)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...
1987-03-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
International Nuclear Information System (INIS)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...
1987-01-01
International Nuclear Information System (INIS)
This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative algorithms, compared with the situation when a constant dwell-time ...
2005-09-01
Oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend-electron beam irradiation
Energy Technology Data Exchange (ETDEWEB)
The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeV electron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies revealed that grafting of the OPEFB fiber with methyl acrylate did not cause appreciable ...
2007-12-15
Energy Technology Data Exchange (ETDEWEB)
Piezoelectric ceramics for acoustic applications have been prepared by mixing the piezoelectric phase Pb{sub 1-1.5x}La{sub x}{open_square}{sub x/2}(Ti{sub 1-y}Zr{sub y})O{sub 3} (PLZT) with variable fractions of Al{sub 2}O{sub 3}. The samples are in form of pellets and polarized at high temperature. After thermal treatment, X-ray diffraction and scanning electron microscopy have been used to determine the phase and morphological modifications. The morphotropic PLZT initial phase disproportionates into modified PLZT and ZrO{sub 2} phases. Using electrical impedance spectroscopy, the resonance frequencies of the composite system have been determined and analyzed. As the Al{sub 2}O{sub 3} volume fractions increase, the resonance frequency and the amplitude of the electrical response both decrease. An interpretation of the role of Al{sub 2}O{sub 3} additions is proposed in terms of phase and microstructure modifications. Using LRC electrical ...
2003-01-15
Energy Technology Data Exchange (ETDEWEB)
Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting ...
1988-07-01
International Nuclear Information System (INIS)
Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve ...
British Library Electronic Table of Contents (United Kingdom)
The glasses with the composition of 37.5Li2O?(25?x)Fe2O3?xNb2O5?37.5P2O5 (mol%) (x=5,10,15) are prepared, and it is found that the addition of Nb2O5 is effective for the glass formation in the lithium iron phosphate system. The glass?ceramics consisting of Nasicon-type Li3Fe2(PO4)3 crystals with an orthorhombic structure are developed through conventional crystallization in an electric furnace, showing electrical conductivities of 3?10?6?Scm?1 at room temperature and the activation energies of 0.48?eV (x=5) and 0.51?eV (x=10) for Li+ ion conduction in the temperature range of 30?200??C. A continuous wave Nd:YAG laser (wavelength: 1064?nm) with powers of 0.14?0.30?W and a scanning speed of 10??m/s is irradiated onto the surface of the glasses, and the formation of Li3Fe2(PO4)3 crystals is c...
2008-01-01
Is there an enhancement of muons at sea level from transient events?
In a recent study of a search for enhancements from the galactic center with muons at sea level using the TUPI muon telescope, we have found several ground level enhancements (GLEs) as very sharp peaks above the count rate background. This paper reports a consistent analysis of two GLEs observed in December 2003 and detected after an up-grade of the data acquisition system, which includes a noise filter and which allows us to verify that the GLEs are not mere background fluctuations. The main target of this study is a search for the origin of the GLEs. The results show that one of them has a strong correlation with a solar flare, while the other has an unknown origin, because there is neither a satellite report of a solar flare, nor prompt X-ray emission, and nor a excess of nuclei during the raster scan where the GLE was observed. Even so, two possibilities are analyzed: the solar flare hypothesis and the gamma ray burst (GRB) hypothesis. We ...
2004-01-01
In situ thermal desorption of H{sub 2} from LiNH{sub 2}-2LiH monitored by environmental SEM
Energy Technology Data Exchange (ETDEWEB)
This article describes in situ heating and observation of a LiNH{sub 2}-2LiH mixture in an environmental scanning electron microscope (ESEM). The LiNH{sub 2}-2LiH mixture showed extensive morphological changes with heating and attendant hydrogen desorption. Static images and real-time movies were obtained during the dehydrogenation process. H{sub 2} evolution commences at {proportional_to}150 C (LiNH{sub 2} + 2LiH {yields} Li{sub 2}NH + H{sub 2} + LiH), and continues until {proportional_to}410 C. Dramatic morphological changes are observed at 220 and 410 C (Li{sub 2}NH + LiH {yields} Li{sub 3}N + H{sub 2}). The material converts to a microcrystalline phase at higher temperatures (>500 C). The observed H{sub 2} desorption and morphological changes occur at temperatures in good agreement with those measured by complementary analytical methods. This is the first time the major structural and morphological changes attendant on H{sub 2} loss from this ...
2009-01-15
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise ...
1987-01-01
Failure analysis of surface-micromachined microengines
Energy Technology Data Exchange (ETDEWEB)
Microelectronic failure analysis (FA) has been an integral part of the development of state-of-the-art integrated circuits. FA of MicroElectroMechanical Systems (MEMS) is moving from its infancy stage to assume an important role in the successful design, fabrication, performance and reliability analysis for this new technology. In previous work, the authors focused on the application of several techniques developed for integrated circuit analysis to an earlier version of a surface micromachined microengine fabricated at Sandia. Recently, they have identified important new failure modes in binary counters that incorporate a newer design of the microengine, using a subset of integrated circuit failure analysis techniques including optical microscopy, focused ion beam (FIB) techniques, atomic force microscopy (AFM), and scanning electron microscopy (SEM). The primary failure mode they have identified is directly related to visible wear on bearing ...
1998-11-01
Burnup determination of spent nuclear fuel in the pool
Energy Technology Data Exchange (ETDEWEB)
A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of the average burnup, cooling time and initial enrichment of the ...
1998-06-01
International Nuclear Information System (INIS)
A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium content in process residues and wastes is 5% with 68.3% of confidence level
1998-09-01
Application of polyacrylonitrile-based polymer electrolytes in rechargeable lithium batteries
DEFF Research Database (Denmark)
Polyacrylonitrile (PAN)-based polymer electrolytes have obtained considerable attention due to their fascinating characteristics such as appreciable ionic conductivity at ambient temperatures and mechanical stability. This study is based on the system PAN-ethylene carbonate (EC)-propylene carbonate (PC)-lithium trifluoromethanesulfonate (LiCF3SO3). The composition 15 mol% PAN-42 mol% EC-36 mol% PC-7 mol% LiCF3SO3 has shown a maximum room temperature conductivity of 1.2 x 10(-3) stop S cm(-1) stop. Also, it was possible to make a thin, transparent film out of that composition. Cells of the form, Li/PAN-EC-PC-LiCF3SO3/polypyrrole (PPy)-alkylsulfonate (AS) were investigated using cyclic voltammetry and continuous charge-discharge tests. When cycled at low scan rates, a higher capacity could be obtained and well-defined peaks were present. The appearance of peaks elucidates the fact that redox reactions occur completely. This well proves the reason ...
2008-01-01
An investigation of the isothermal creep response of Al-based composites by neutron diffraction
Energy Technology Data Exchange (ETDEWEB)
Discontinuously reinforced aluminium-based composites containing particulate or whisker SiC reinforcements at different volume fractions, were produced via a powder-route. Isothermal creep tests have been carried out at 270, 300 and 320 C. During these tests axial and transverse strains were monitored using a non-contacting laser scanning extensometer arrangement. At the same time neutron diffraction has been used to measure the elastic phase strain evolution with composite creep deformation. It was found that after the initial loading the phase strains remained essentially constant during primary and secondary creep. This indicates that the initial matrix/reinforcement inelastic misfits remain largely unchanged, probably due to the setting up of a dynamic equilibrium between misfit generation and stress relaxation. For each system, the neutron data has been combined with Eshelby modelling to obtain a measure of the load transfer. It was found ...
2000-05-31
Aluminum assisted electrodeposition of europium in LiCl-KCl molten salt
Energy Technology Data Exchange (ETDEWEB)
Cyclic voltammetry (CV), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) were employed to investigate the electrodeposition of Eu and Al in an LiCl-KCl eutectic melt containing Eu{sup 2+} and Al{sup 3+} at 450 deg. C. In order to deposit a pure Eu and Al alloy, the stoichiometrically lower concentration of Al{sup 3+} than that of Eu{sup 2+} and Al wires as a counter electrode was introduced into the bath of LiCl-KCl melt for the electrodeposition. The electrodeposition takes place at a potential more negative than -1.95 V vs. Ag|Ag{sup +} while the deposit is oxidized at more positive potential than -1.92 V. Two new reduction peaks and an anodic peak on a W working electrode were observed at -2.39 V, -2.42 V, and -2.1 V, vs. Ag|Ag{sup +}, respectively, suggesting that the potential window of the Al system in LiCl-KCl melt can be extended to -2.43 V vs. Ag|Ag{sup +}. The EDS analysis indicated that AlEu can be ...
2010-03-01
Aluminum assisted electrodeposition of europium in LiCl-KCl molten salt
International Nuclear Information System (INIS)
Cyclic voltammetry (CV), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) were employed to investigate the electrodeposition of Eu and Al in an LiCl-KCl eutectic melt containing Eu2+ and Al3+ at 450 deg. C. In order to deposit a pure Eu and Al alloy, the stoichiometrically lower concentration of Al3+ than that of Eu2+ and Al wires as a counter electrode was introduced into the bath of LiCl-KCl melt for the electrodeposition. The electrodeposition takes place at a potential more negative than -1.95 V vs. Ag|Ag+ while the deposit is oxidized at more positive potential than -1.92 V. Two new reduction peaks and an anodic peak on a W working electrode were observed at -2.39 V, -2.42 V, and -2.1 V, vs. Ag|Ag+, respectively, suggesting that the potential window of the Al system in LiCl-KCl melt can be extended to -2.43 V vs. Ag|Ag+. The EDS analysis indicated that AlEu can be deposited at the potential more negative than ...
2010-03-01
3-Dimensional Mapping of Corneal Topography and Thickness
Optical sections of the cornea are obtained by illumination with a collimated beam expanded in a fan shape by a small rotary cylindrical lens. The light diffused from the cornea is observed by two cameras and processed in order to yield the surfaces' profiles. The optical system used to project a thin rotating line on the cornea consists of a white light source provided with optical fiber bundle output which is first conditioned by a set of lenses so that it would produce a spot on the cornea. A small cylinder lens is used to expand the beam in one direction so that a thin line illuminates the cornea, rather than a spot. The cylinder lens is provided with motor driven rotation about an axis normal to its own in order to rotate the line on the cornea such that the projected line scans the whole cornea; the illuminator is completed with a slit aperture. The cornea is not perfectly transparent, scattering some of the light that traverses it; this ...
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The ...
2003-03-15
International Nuclear Information System (INIS)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The ...
2003-03-01
IMPROVED NATURAL GAS STORAGE WELL REMEDIATION
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report covers activities ...
2001-12-01
International Nuclear Information System (INIS)
Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).
International Nuclear Information System (INIS)
In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.
2001-10-01
Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.
A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192
2002-11-01
Electrochemical characterization of MnO2 as the cathode material for a high voltage hybrid capacitor
British Library Electronic Table of Contents (United Kingdom)
Manganese dioxide (MnO2) was prepared using the ultrasonic method. Its electrochemical performance was evaluated as the cathode material for a high voltage hybrid capacitor. And the specific capacitance of the MnO2 electrode reached 240 F.g-1. The new hybrid capacitor was constructed, combining Al/Al2O3 as the anode and MnO2 as the cathode with electrolyte for the aluminum electrolytic capacitor to solve the problem of low working voltage of a supercapacitor unit. The results showed that the hybrid capacitor had a high energy density and the ability of quick charging and discharging according to the electrochemical performance test. The capacitance was 84.4 mF, and the volume and mass energy densities were greatly improved compared to those of the traditional aluminum electrolytic capacito...
2009-01-01
Elastic properties, hardness and indentation fracture toughness of #beta#-sialons
International Nuclear Information System (INIS)
Dense samples of #beta#-sialons (with z from 1 to 4) were pressuressly sintered for different time (15-240 minutes) and at relatively low temperature of 1600 C using single-phase #beta#-sialon powders synthesized by combustion nitridation. The samples were characterized using ultrasonic method for determination of elastic properties (E,G,#mu#). Also, hardness by Knoop and fracture toughness by Vickers indentation microfracture method was estimated. With increasing z number Young's modulus decreases from 293 to 179 GPa. Simultaneously Poisson ratio increases by about 30%. The highest values of hardness and fracture toughness were obtained for sialon with z equal to 1. (orig.).
1993-10-04
Energy Technology Data Exchange (ETDEWEB)
An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a continuously varying focus in accordance ...
1981-07-07
Energy Technology Data Exchange (ETDEWEB)
Stoichiometric MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA at temperatures between 385 and 750C to fluences ranging from 2.2 to 24.9 {times} 10{sup 22}n cm{sup {minus}2} (E>0.1 MeV) darken significantly, but do not develop any significant loss in weight or change in dimensions. Similar behavior was observed in both single crystal and fully dense polycrystalline specimens. Measurements of elastic constants by an ultrasonic technique show that no measurable changes occur as a result of the irradiation. These and other results confirm the stability of this material for fusion application as an electrical insulator.
1993-10-01
British Library Electronic Table of Contents (United Kingdom)
SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...
2011-01-01
Behavior of trace refractory minerals in the lithium metaborate fusion-acid dissolution procedure
The feasibility of this procedure was investigated using minerals and ore specimens. The substances were ground then fused using LiBO/sub 2/, quenched with 3% HNO/sub 3/ or mixtures of the acid with 2.5% tartaric acid or 30% H/sub 2/O/sub 2/. The quenched melt was usually completely dissolved within 20 min by placing the beakers in an ultrasonic bath. If any residue was detected, appropriate changes were made in the procedure. Once the procedure has been optimized, any remaining black particles were filtered. If these particles disappeared upon subsequent ignition, they were presumed to have been graphite. Most of the refractory minerals investigated should be expected to be converted to soluble form by this process. 1 table.
1983-12-01
Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures
International Nuclear Information System (INIS)
Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, ...
2005-04-01
We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the ...
2010-11-10
Failed nuclear fuel rod analysis by gamma computed tomography
International Nuclear Information System (INIS)
Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such distributions in the area of ...
Energy Technology Data Exchange (ETDEWEB)
The biological literature is huge and increasingly moving to electronic form. By developing a variety of new techniques, it should be possible to take advantage of this huge and growing electronic store. Computers should allow one to use the literature with greater efficiency and insight to disseminate information and to advance scientific understanding. Though there is a great deal of research and development effort focused on electronic text, e.g., the Digital Libraries initiative, little attention has been paid to the diagrammatic content of documents. However, it is common knowledge among biologists, and scientists in general, that the figures in documents are of critical importance. Little work has been done to develop principles and systems for analyzing, representing, and indexing and searching the diagrammatic content of electronic documents. This has been the main thrust of this research project. The primary work in the world on the analysis of graphics in ...
1997-04-04
Effect of Ba on ferroelectric and piezoelectric properties of the PLZT (1.2/55/45) system
International Nuclear Information System (INIS)
Ferroelectric Pb_0_._9_8_2_-_zLa_0_._0_1_2#DELTA#_0_._0_0_6Ba_z(Zr_0_._5_5Ti_0_._4_5)O_3 (PLZT; z = 0-6 mol%) ceramic compositions were fabricated by a mixed-oxide method. X-ray diffraction studies of sintered ceramics indicate the coexistence of rhombohedral and tetragonal phases in the 5 mol% Ba-doped PLZT composition. Grain growth is inhibited with increasing Ba concentration in the PLZT system as evidenced by scanning electron micrographs. Dielectric constant and dielectric loss as a function of temperature suggest that #epsilon#_r_t and tan #delta# are increased up to compositions containing 4 and 5 mol% Ba, respectively. The dielectric maximum (#epsilon#_T_c) decreased to 4 mol% Ba and gradually increased to 6 mol% Ba, whereas, with increasing Ba concentration in the PLZT system, the Curie temperature (T_C) decreased from the composition with no Ba to that with 6 mol% Ba. Relaxor behavior as a function of temperature ...
2006-06-01
ALOS satellite imagery utilizations for safeguards
International Nuclear Information System (INIS)
This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an inclination angle of 98.16 degrees, 691.65 km ...
2006-10-16
Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma
International Nuclear Information System (INIS)
Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening ...
International Nuclear Information System (INIS)
Thirty-six patients with acquired immunodeficiency syndrome (AIDS), who were febrile but without localizing signs, underwent indium-111 leukocyte scintigraphy 24 hours after injection of labeled white blood cells (WBCs) and were restudied 48 hours after injection of gallium-67 citrate. Fifty-six abnormalities were identified as possible sources of the fever; 27 were confirmed with biopsy. Of these 27, 15 were identified only on In-111 WBC scans (including colitis, sinusitis, and focal bacterial pneumonia); six, only on Ga-67 scans (predominantly Pneumocystis carinii pneumonia and lymphadenopathy); and six, on both studies (predominantly pulmonary lesions). In-111 WBC scanning revealed 21 of 27 abnormalities (78%) and gallium scanning, 12 of 27 (44%). If only one scintigraphic study has been performed, particularly with Ga-67, a significant number of lesions would not have been detected. The authors ...
CT diagnosis of intrahepatic cholangiocarcinoma
International Nuclear Information System (INIS)
Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast ...
The value of computed tomography in the diagnosis of grating scapula
Energy Technology Data Exchange (ETDEWEB)
Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)
1994-07-01
Role of nuclear medicine bone scans in evaluating pain in athletic injuries
Energy Technology Data Exchange (ETDEWEB)
The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.
1987-10-01
Bone scanning in Ewing's sarcoma
International Nuclear Information System (INIS)
This is a retrospective analysis of bone scans in 72 patients with Ewing's sarcoma. Sites of primary disease were found to be evenly distributed among the axial skeleton and the proximal and distal extremities. Primary disease sites in the axial skeleton were more frequently associated with metastases. Fifty-three of these patients had their first scans done at presentation; among them, 25 were found to have metastases. Unsuspected metastases were picked up in 28 of all the patients. Metastases at presentation were seen to be associated with a poorer prognosis.
Size determination of Acipenser ruthenus spermatozoa in different types of electron microscopy
British Library Electronic Table of Contents (United Kingdom)
In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde...
2010-01-01
... point dried and mounted on aluminum stubs using colloidal silver paste. Mounted specimens were observed and photographed using ... ...
New Image - ONLY - Scan to PDF - NASA Technical Reports Server
Aluminum electrolytic capacitors are presently not allowed ..... specified for commercial aluminum electrolytic capacitors of similar rating. ...
New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)
Variations,of-the ,rudder pedel force with.indicated airspeed are shown in figure 16 for the six vertical-tail configurations. -tested. ...
New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)
ratio 2 with NACA 0005-63 thickness distribution in streamwise planes, and twisted and cambered for a trapezoidal span load distribution has ...
High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry
In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.
2004-01-01
Habitat Selection by Mountain Plovers in Shortgrass Steppe
... the area covered by the point-count grid, stopping approximately every 100 m, stepping away from the vehicle, and scanning with binoculars for mountain plovers. Once ... ...
Advances in Modeling of Scanning Charged-Particle-Microscopy Images
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This work describes scanning in charged-particle microscopes, which is applied both in the artificial image generator and the DCIC ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent ...
2006-03-15
Energy Technology Data Exchange (ETDEWEB)
A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl chloride tube becomes ...
1997-05-27
What Can a Dual beam Really Do?
International Nuclear Information System (INIS)
Full Text: Smallstage Dualbeam (SDB) systems, that is a Focussed Ion Beam column coupled with a SEM column, have been around for about five years now. There impact on the Semiconductor industry has been enormous, with virtually every lab having a SDB to produce, characterise and analyse cross sections and TEM samples on the Nano-scale. But what about other industries? What else can SDB system be used for? The SEM column in itself is a very powerful tool for sample characterisation, modification and analysis. An electron beam from a Tungsten or Thermal Field Emission source has enough current to allow sophisticated patterns to be created in photo-resist samples, a process known as lithography. The current is also high enough to allow for a process known as Electron Beam Induced Deposition (EBID), where the beam interacts with an introduced gas and material is deposited in a controlled manner on the sample. With the addition of the Focussed Ion ...
2005-08-16
We report on the effect of potato maltodextrins with variable dextrose equivalent (Paselli SA-2, SA-6 and SA-10) on the surface behavior at the air-water interface of the mixture: legumin+small-molecule surfactant. Distinct in nature small-molecule surfactants (model: sodium salt of capric acid, Na-caprate; and commercially important: a citric acid ester of monoglyceride, CITREM) have been under our consideration. The role of the structure of both of the maltodextrins and the small-molecule surfactants in the effect studied has been elucidated by measurements in a bulk aqueous medium of the enthalpy of their interaction from mixing calorimetry, value of weight average molecular weight of the maltodextrins and the thermodynamics of the pair maltodextrin-solvent and maltodextrin-protein interactions from laser static light scattering. The combined data of mixing calorimetry and light scattering suggest some complex formation between the small-molecule surfactants and the maltodextrins. ...
2001-07-01
Structure and property relationship in the mixed-conducting Sr-Fe-Co-O system.
Energy Technology Data Exchange (ETDEWEB)
Mixed-conducting ceramic oxides have potential uses in high-temperature electrochemical applications such as solid oxide fuel cells, advanced batteries, sensors, and oxygen-permeable membranes. The Sr-Fe-Co-O system combines high electronic/ionic conductivity with appreciable oxygen permeability at elevated temperatures. Dense ceramic membranes made of this material can be used to separate high-purity oxygen from air without the need for external electrical circuitry, or to partially oxidize methane to produce syngas. Samples of Sr{sub 2}Fe{sub 3{minus}x}Co{sub x}O{sub y} (with x = 0, 0.6, 1.0, and 1.4) were prepared by solid-state reaction in atmospheres with various oxygen partial pressures (pO{sub 2}) and were characterized by X-ray diffraction, scanning electron microscopy, and electrical conductivity measurements. Phase components of the samples are dependent on cobalt concentration and synthesis pO{sub 2}. Total conductivity increases ...
1998-05-18
International Nuclear Information System (INIS)
Single phase amorphous Al_xHf_1_0_0_-_x alloys with a wide amorphization range (33#<=#x#<=#75) were synthesized by the solid-state interdiffusion of pure polycrystalline Al and Hf powders at room temperature using a rod-milling technique. The mechanisms of metallic glass formation and competing crystallization processes in the mechanically deformed composite powders were investigated by means of X-ray diffraction, differential thermal analysis, scanning electron microscopy and transmission electron microscopy. The numerous intimate layered composite particles of the diffusion couples that formed during the first and intermediate stages of milling (0-173 ks) are intermixed to form amorphous phase(s) upon heating to about 980 K by so-called thermally assisted solid-state amorphization (TASSA). The amorphization heat formation for the binary Al_xHf_1_0_0_-_x system via TASSA, #DELTA#H"T"A"S"S"A_a, was measured directly as a function of the ...
1999-03-04
Energy Technology Data Exchange (ETDEWEB)
Lithium ion conducting glass ceramics composed of the crystalline conductive phase Li{sub 1.4}Al{sub 0.4}(Ge{sub 1-x}Ti{sub x}){sub 1.6}(PO{sub 4}){sub 3}(x=0-1.0) with the Nasicon-type structure have been synthesized and characterized by DTA, X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM) and complex impedance techniques. The experimental results indicated that the glass ceramics were mainly composed of solid solution Li(Ge{sub 1-x}Ti{sub x}){sub 2}(PO{sub 4}){sub 3} formed by LiGe{sub 2}(PO{sub 4}){sub 3} and LiTi{sub 2}(PO{sub 4}){sub 3} in the whole x range and showed conductivity over 10{sup -4} S/cm at room temperature. The maximum room temperature lithium ion conductivity of 6.21x10{sup -4} S/cm with an activation energy as low as 0.32 eV was obtained for the Li{sub 1.4}Al{sub 0.4}(Ge{sub 0.67}Ti{sub 0.33}){sub 1.6}(PO{sub 4}){sub 3} treated at 950 C for 18 h. Mechanisms for the enhancement of {sigma}{sub totle} in glass ...
2004-07-30
Fabrication of metallic contacts to nanometre-sized materials using a focused ion beam (FIB)
Energy Technology Data Exchange (ETDEWEB)
Nanometre-sized materials, like nanowires, nanoparticles or nanobelts, are gaining huge interest as building blocks of modern electronic nanodevices. Their fabrication feasibility has been demonstrated in the last years, and different routes are already well established in order to synthesize these materials. However, the assessment of their electrical properties is still a challenging issue, due to the difficulty to perform a precise nanolithography process allowing the access to such small structures. The fabrication of metallic contacts with precision in the nanometre range is necessary, as well as achieving a flexible system that allows to contact individual structures. Such a system could be a dual-beam Focused Ion Beam instrument, which combines Scanning Electron Microscopy (SEM) and Focused Ion Beam (FIB) in one machine, able to assist deposition of materials with nanometre precision. In this work, the methodology of ...
2006-07-15
Fabrication of metallic contacts to nanometre-sized materials using a focused ion beam (FIB)
International Nuclear Information System (INIS)
Nanometre-sized materials, like nanowires, nanoparticles or nanobelts, are gaining huge interest as building blocks of modern electronic nanodevices. Their fabrication feasibility has been demonstrated in the last years, and different routes are already well established in order to synthesize these materials. However, the assessment of their electrical properties is still a challenging issue, due to the difficulty to perform a precise nanolithography process allowing the access to such small structures. The fabrication of metallic contacts with precision in the nanometre range is necessary, as well as achieving a flexible system that allows to contact individual structures. Such a system could be a dual-beam Focused Ion Beam instrument, which combines Scanning Electron Microscopy (SEM) and Focused Ion Beam (FIB) in one machine, able to assist deposition of materials with nanometre precision. In this work, the methodology of ...
2006-07-01
International Nuclear Information System (INIS)
Full text: Certain groups of patients have been excluded from ventilation lung scanning due to their inability to comply with instruction. Tetley Manufacturing have recently developed a Positive Ventilation Delivery System (PVDS) which assists in delivering Technegas to patients who are unable to cooperate fully. The aim of this study is to evaluate the PVDS in the clinical setting. Fifteen frail aged and psychogeriatric patients (n=l 5), mean age 78 years (range 60-93), were ventilated with Technegas using the PVDS. The decision to ventilate the patient with the PVDS was based on an initial assessment of the patients ability to comply with instructions, or failure of the conventional ventilation method, to produce an adequate count rate. Technegas was prepared in the usual manner and then delivered to the patients lungs by squeezing a black anesthetic bag synchronously with the patients breathing, until a count rate of approximately 1000 ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
Batch and dynamic flow biosorption studies were carried out using the waste biomass entrapped in silica-gel matrix for the removal of nickel(II) ions from synthetic solutions and real wastewater. Batch biosorption conditions were examined with respect to initial pH, S/L ratio, contact time, and initial nickel ion concentration. Zeta potential measurements showed that immobilized biosorbent was negatively charged in the pH range of 3.0-8.0. The immobilized biomass was found to possess relatively high biosorption capacity (98.01 mg g{sup -1}), and biosorption equilibrium was established in a short time of operation (5 min). The equilibrium data were followed by Langmuir, Freundlich, and Dubinin-Radushkevich isotherm models. Scanning electron microscope analysis was used to screen the changes on the surface structure of the waste biomass after immobilization and nickel(II) biosorption. Sorbent-sorbate interactions were confirmed by Fourier transform infrared ...
2009-04-30
Effects of ion-induced electron emission on magnetron plasma instabilities
International Nuclear Information System (INIS)
Some magnetron sputtering systems experience rapid oscillations in the current and voltage of the plasma discharge after several hours when equipped with certain targets. These oscillations often lead to the plasma becoming extinguished, a condition known as ''flame-out.'' This article details the study of two 90% W--10% Ti magnetron targets which differed in density. The higher density targets sometimes experienced flame-out after approximately 3 h of sputtering. The less dense material could be sputtered for the entire 15 h life of the target. Scanning electron microscopy pictures and atomic composition depth profiles were obtained using Auger electron spectroscopy. In addition, a Colutron-based ion source with a high vacuum system was used to measure ion-induced secondary electron emission coefficients as a function of energy, ion specie, and gas coverage. Analysis of the sample from the group that suffers flame-out ...
Development of materials resistant to metal dusting degradation.
Energy Technology Data Exchange (ETDEWEB)
Metal dusting corrosion has been a serious problem in the petroleum and petrochemical industries, such as reforming and syngas production systems. This form of deterioration has led to worldwide material loss for 50 years. For the past three years, we have studied the mechanism of metal dusting for Fe- and Ni-base alloys. In this report, we present a correlation between the weight loss and depth of pits that form in Ni-base alloys. Nickel-base alloys were also tested at 1 and 14.8 atm (210 psi), in a high carbon activity environment. Higher system pressure was found to accelerate corrosion in most Ni-base alloys. To reduce testing time, a pre-pitting method was developed. Mechanical scratches on the alloy surface led to fast metal dusting corrosion. We have also developed preliminary data on the performance of weldments of several Ni-base alloys in a metal dusting environment. Finally, Alloy 800 tubes and plates used in a reformer plant were ...
2006-04-24
Energy Technology Data Exchange (ETDEWEB)
Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...
2000-10-01
UK PubMed Central (United Kingdom)
BackgroundThe Prospective Space-Time scan statistic (PST) is widely used for the evaluation of space-time clusters of point event data. Usually a window of cylindrical shape is employed,...Full Text Available
Scanning tip microwave near-field microscope
Energy Technology Data Exchange (ETDEWEB)
A near-field microscope which operates in the rf/microwave frequency range is described. In this microscope, a scanning tunneling microscope (STM)-like tip rather than an aperture is used as a point-like evanescent field emitter. A spatial resolution of {approximately}5 {mu}m ({approximately}{lambda}/100000) is achieved in the current version. The design of the microscope as well as the principal factors which affect its performance are discussed. {copyright} {ital 1996 American Institute of Physics.}
1996-06-01
Practical MRI atlas of neonatal brain development
International Nuclear Information System (INIS)
This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.
Paraquat-induced pulmonary lesions : HRCT findings in long-term follow-up : a case report
International Nuclear Information System (INIS)
We illustrate serial HRCT findings over a 16-month period in a 35-year-old woman who had ingested paraquat. Initial areas of ground-glass opacity changed into areas of multiple air cysts on follow up scan obtained five months after ingestion. A further follow-up scan obtained 16 months after ingestion showed improvement, with increased lung volume and normalized lung architecture.
1997-03-01
Magnetic resonance imaging in acute intractional tuberculosis
International Nuclear Information System (INIS)
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
Isolated dextrogastria: report of two cases
International Nuclear Information System (INIS)
Isolated situs inversus of the stomach with otherwise normal position of the thoracic and abdominal viscera is an extremely rare anomaly occurring in two distinct forms. Because of its close relationship to the liver, the right-sided stomach may produce interesting and confusing changes in the liver scan. Two cases illustrate the radiologic features of the two principal types of isolated congenital dextrogastria and the effect of one type on the liver scan.
Energy Technology Data Exchange (ETDEWEB)
We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)
2001-02-01
Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle
Energy Technology Data Exchange (ETDEWEB)
The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.
1988-10-13
International Nuclear Information System (INIS)
A bone scan can be negative in Ewing's sarcoma. The bone scan during and after treatment can give prognostic information on the primary tumor site: A persisting hot spot strongly suggests the presence of local malignancy, while a hot spot becomming negative points to local cure of Ewing's sarcoma. (orig.).
Energy Technology Data Exchange (ETDEWEB)
Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level ...
1984-09-01
[Preparation of titanium dioxide particles and properties for flue gas desulfurization].
Under different sintering temperatures(340 degrees C, 440 degrees C, 540 degrees C, 640 degrees C), four TiO2 particles were prepared. The crystal types of all four samples were found to possess anatase structures by XRD. It was obtained by N2 experimental adsorption at low temperature (77K) that their surface areas and average pore size were between 79 and 124 m2/g, 56.8 and 254.8 A respectively. The pore structure of TiO2 particles was characterized by scanning electron microscope (SEM). The tests of adsorption dynamics for FGD and the performance of SO2 removal were investigated in a fixed-bed system for different samples. The results show that SG540 sample which made at 540 degrees C sintering temperature had the most quality among the four samples. It can adsorb SO2 of 38.9 mg for one gram SG540 sample. Different operating conditions for SG540 such as adsorption temperature, SO2 concentration in flue gas and the superficial velocity of ...
2003-01-01
X-ray ablation measurements and modeling for ICF applications
Energy Technology Data Exchange (ETDEWEB)
X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are also described. ...
1996-09-01
Thermochemistry of mixed explosives
Energy Technology Data Exchange (ETDEWEB)
In order to predict thermal hazards of high-energy materials, accurate kinetics constants must be determined. Predictions of thermal hazards for mixtures of high-energy materials require measurements on the mixtures, because interactions among components are common. A differential-scanning calorimeter (DSC) can be used to observe rate processes directly, and isothermal methods enable detection of mechanism changes. Rate-controlling processes will change as components of a mixture are depleted, and the correct depletion function must be identified for each specific stage of a complex process. A method for kinetics measurements on mixed explosives can be demonstrated with Composition B is an approximately 60/40 mixture of RDX and TNT, and is an important military explosive. Kinetics results indicate that the mator process is the decomposition of RDX in solution in TNT with a perturbation caused by interaction between the two components. It is concluded that a ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The present study deals with two subjects. The first one is to determine the thermal properties of lauric acid (LA)-stearic acid (SA), myristic acid (MA)-palmitic acid (PA) and palmitic acid (PA)-stearic acid (SA) eutectic mixtures as latent heat storage material. The properties were measured by the differential scanning calorimetry (DSC) analysis technique. The second one is to study the thermal reliability of these materials in view of the change in their melting temperatures and latent heats of fusion with respect to repeated thermal cycles. For this aim, the eutectic mixtures were subjected to 360 repeated melt/freeze cycles, and their thermal properties were measured after 0, 90,1 80 and 360 thermal cycles by the technique of DSC analysis. The DSC thermal analysis results show that the binary systems of LA-SA in the ratio of 75.5:24.5 wt.%, MA-PA in the ratio of 58:42 wt.% and PA-SA in the ratio of 64.2:35.8 wt.% form eutectic mixtures ...
2004-02-01
The Two-Column Aerosol Project (TCAP) Science Plan
Energy Technology Data Exchange (ETDEWEB)
The Two-Column Aerosol Project (TCAP) field campaign will provide a detailed set of observations with which to (1) perform radiative and cloud condensation nuclei (CCN) closure studies, (2) evaluate a new retrieval algorithm for aerosol optical depth (AOD) in the presence of clouds using passive remote sensing, (3) extend a previously developed technique to investigate aerosol indirect effects, and (4) evaluate the performance of a detailed regional-scale model and a more parameterized global-scale model in simulating particle activation and AOD associated with the aging of anthropogenic aerosols. To meet these science objectives, the Atmospheric Radiation Measurement (ARM) Climate Research Facility will deploy the ARM Mobile Facility (AMF) and the Mobile Aerosol Observing System (MAOS) on Cape Cod, Massachusetts, for a 12-month period starting in the summer of 2012 in order to quantify aerosol properties, radiation, and cloud characteristics at a location subject ...
2011-07-27
Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements reveal an interesting ...
2009-07-01
Performance of a high Cr and Ni austenitic stainless steel plates in PEMFC working environments
Energy Technology Data Exchange (ETDEWEB)
The high cost of proton exchange membrane fuel cells (PEMFCs) poses a significant challenges to their commercial uptake. The bipolar plates connect the anode and cathodes of cells and separate the reactant gases, and are the most expensive components in PEMFCs. Although stainless steel can be used as a low-cost alternative in bipolar plate construction, steel is prone to electrochemical corrosion in the highly acidic PEMFC operation process. This study examined the polarization curves and ICR as a function of compaction force of a high Cr and Ni austenitic stainless steel in an environment simulating the bipolar plate under PEMFC operating conditions. The 3-electrode system consisted of a platinum (Pt) sheet, a saturated calomel electrode with a Luggin capillary contract with the used solution and the work electrode. All polarization curves were measured in a solution of H{sub 2}SO{sub 4} in order to simulate the aggressive PEMFC environment. Surface morphologies ...
2006-07-01
Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers
International Nuclear Information System (INIS)
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and focus-to-surface ...
2001-11-01
International Nuclear Information System (INIS)
For higher U-loading in low-enriched U-10 wt.%Mo fuels, monolithic fuel plate clad in AA6061 is being developed as a part of Reduced Enrichment for Research and Test Reactor (RERTR) program. This paper reports the first characterization results from a monolithic U-10 wt.%Mo fuel plate with a Zr diffusion barrier that was fabricated as part of a plate fabrication campaign for irradiation testing in the Advanced Test Reactor (ATR). Both scanning and transmission electron microscopy (SEM and TEM) were employed for analysis. At the interface between the Zr barrier and U-10 wt.%Mo, going from Zr to U(Mo), UZr_2, #gamma#-UZr, Zr solid-solution and Mo_2Zr phases were observed. The interface between AA6061 cladding and Zr barrier plate consisted of four layers, going from Al to Zr, (Al, Si)_2Zr, (Al, Si)Zr_3 (Al, Si)_3Zr, and AlSi_4Zr_5. Irradiation behavior of these intermetallic phases is discussed based on their constituents. Characterization of as-fabricated phase ...
2010-07-01
A simple approach to controlling the loading percentage and size of zero-valent iron nanoparticles (ZVI NPs) immobilized within polyacrylic acid (PAA)/polyvinyl alcohol (PVA) nanofibrous mats for dye remediation applications is described. A functional "nanoreactor" comprised by electrospun PAA/PVA nanofibers served to bind ferric ions with the carboxyl groups of PAA, prior to their reduction to ZVI NPs. The resulting ZVI NP-immobilized hybrid polymer nanofibers were characterized using scanning electron microscopy, transmission electron microscopy, and thermogravimetric analysis. The morphology of the polymer nanofibers exhibited no appreciable change even after eight cycles of ferric ion binding/reduction, and the loading percentage and size of the ZVI NPs were controlled simply by varying the number of ferric ion binding/reduction cycles. Dye remediation experiments revealed that the decoloration effect of ZVI NPs immobilized within the polymer nanofibers is both ...
2011-06-01
Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone
Energy Technology Data Exchange (ETDEWEB)
Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal association cortex) and multiple Heschl`s ...
1995-06-19
Light-weight free-standing carbon nanotube-silicon films for anodes of lithium ion batteries.
Silicon is an attractive alloy-type anode material because of its highest known capacity (4200 mAh/g). However, lithium insertion into and extraction from silicon are accompanied by a huge volume change, up to 300%, which induces a strong strain on silicon and causes pulverization and rapid capacity fading due to the loss of the electrical contact between part of silicon and current collector. Si nanostructures such as nanowires, which are chemically and electrically bonded to the current collector, can overcome the pulverization problem, however, the heavy metal current collectors in these systems are larger in weight than Si active material. Herein we report a novel anode structure free of heavy metal current collectors by integrating a flexible, conductive carbon nanotube (CNT) network into a Si anode. The composite film is free-standing and has a structure similar to the steel bar reinforced concrete, where the infiltrated CNT network functions as both ...
2010-07-27
Energy Technology Data Exchange (ETDEWEB)
Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat transfer coefficient between the heat transfer fluid (HTF) pipe and the PCM, heat recovery ...
2005-04-01
Energy Technology Data Exchange (ETDEWEB)
Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe Microanalysis), AES (Auger Electron Spectroscopy) and XPS (X-ray Photoelectron ...
1999-07-15
International Nuclear Information System (INIS)
Cigarette smoking is the major environmental risk factor for bladder cancer in humans. Aromatic amines, potent DNA-reactive bladder carcinogens present in cigarette smoke, contribute significantly. However, increased cell proliferation, caused by direct mitogenesis or in response to cytotoxicity, may also play a role since urothelial hyperplasia has been observed in human cigarette smokers. We examined the urothelial effects of cigarette smoke (whole body inhalation exposure (Teague) system) in female C57BL/6 mice at various times in two studies, including reversibility evaluations. In both studies, no urothelial hyperplasia was observed by light microscopy in any group. However, in study 1, the Ki-67 labeling index (LI) of the urothelium was significantly increased in the smoke exposed group compared to controls through 3 months, but was not present at 6, 9 or 12 months even with continued exposures. In the groups that discontinued smoke exposure, it returned to ...
2007-11-20
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
Energy Technology Data Exchange (ETDEWEB)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the ...
1987-04-01
Energy Technology Data Exchange (ETDEWEB)
The first of three scheduled poolside fuel examinations at the Oyster Creek reactor conducted during February/March 1980, was directed at one of the four symmetrically loaded ENC 8 x 8 lead assemblies that had achieved a burnup of approx. 25,000 MWd/MTU. Forty-five of the fuel rods in assembly UD3-109 were removed and examined. In general, the individual fuel rods were in excellent condition. The average fuel rod diameter continued to decrease during the last cycle was assembly burnup increased from 19,500 to 25,700 MWd/MTU. The creepdown since the beginning of life (BOL) in the center of the fuel rods is about 0.003 in. The fuel rods bore no indication of cladding ridging. Fuel rod growth continued at a linear rate of about 0.02% per GWd/MTU burnup since BOL. Preliminary eddy current test data showed that the cladding was free of significant defects. Visual examination of fuel rods, spacers, and tie plate revealed no unusual conditions. An average assembly burnup of 31,000 MWd/MTU is ...
1980-12-31
In the present work, a new kind of myoglobin (Mb)/Au nanoparticles composite film was fabricated on pyrolytic graphite (PG) electrodes. Oppositely charged chitosan (CS) and silica (SiO(2)) nanoparticles were alternately adsorbed on the PG surface by the electrostatic interaction between them, forming {CS/SiO(2)}(5) layer-by-layer films. Mb and HAuCl(4) in solution were then simultaneously loaded into {CS/SiO(2)}(5) films. The loaded Au(III) in the films were electrochemically reduced into Au nanoparticles, forming nanocomposite films, designated as {CS/SiO(2)}(5)-Mb-Au. Various techniques such as cyclic voltammetry (CV), square wave voltammetry (SWV), quartz crystal microbalance (QCM), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and energy dispersive X-ray (EDX) analysis were used to characterize the films. Compared with {CS/SiO(2)}(5)-Mb films without Au nanoparticles inside, the {CS/SiO(2)}(5)-Mb-Au films exhibited much ...
2008-12-01
International Nuclear Information System (INIS)
Thermo-reactive diffusion chromizing followed by pulsed plasma nitriding were carried out on AISI 52100 and 8620 bearing steels. The chromized samples were pulse-plasma nitrided for 5 h at 500 deg. C in various N_2-H_2 gas mixtures. The coated steels were characterized using scanning electron microscopy, X-ray diffraction and microhardness testing. The unlubricated wear behaviors of only chromized and duplex treated steels were investigated in ball-on-disc system tests at room temperature. X-ray diffraction patterns of the duplex treated samples containing H_2 indicated the formation of dominant CrN and Cr_2N nitrides as well as the formation of Cr_3C_2 and Cr_7C_3 carbides. Gas mixtures in the plasma nitriding, which was performed after chromizing, have a significant influence on the wear rate of the duplex treated steels. The wear and friction tests showed that the lowest friction coefficient and wear rates were observed for the samples ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM images, the signal ...
1998-11-01
Energy Technology Data Exchange (ETDEWEB)
A geological study was conducted to better understand the nature of cleat development and degree of mineralization in coal seams of the Scollard and Coalspur Formations in western Alberta. The results can be applied to equivalent formations. The source and reservoir rocks of a coalbed methane (CBM) system were described. Coal seams are basically fractured reservoirs with 7 types of cleats. The field work involved cleat minerals sampling and determining cleat attributes such as type, strike and spacing from open-cut mines and outcrops. The laboratory work involved X-Ray diffraction, scanning electron microscopy, energy dispersive microscopy, stable isotope analysis, and fluid inclusions analysis. The study showed that coal seams of the Scollard and Coalspur Formations are widespread and cleated to various degrees. The face and butt cleats strike northeast-southwest and northwest southeast respectively along the structural grain of the Laramide ...
2004-07-01
Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997
Energy Technology Data Exchange (ETDEWEB)
This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the automated ...
1998-07-01
British Library Electronic Table of Contents (United Kingdom)
Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
We present a 1-D heat transfer, melting, vaporization and resolidification model describing the interaction of a scanning continuous-wave laser with a metal surface wherein the beam power is constant. A physical model based on the Stefan problem is developed with appropriate boundary conditions. The effects of processing parameters on process variables are investigated numerically by varying beam diameters, scan speeds and substrate temperatures for Nickel. Relations are derived for the times to initiate melting, to initiate vaporization, to reach maximum melting depth, for melting-resolidification, and for maximum melting and vaporization depths. Surface temperatures are compared with approximate closed form solutions. (Author)
2004-09-01
International Nuclear Information System (INIS)
Scanning thermal microscopy (SThM) was used to map thermal conductivity images in an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment (SMAT). It is found that the deformed surface layer shows different thermal conductivities that strongly depend on the grain size of the microstructure: the thermal conductivity of the nanostructured surface layer decreases obviously when compared with that of the coarse-grained matrix of the sample. The role of the grain boundaries in thermal conduction is analyzed in correlation with the heat conduction mechanism in pure metal. A theoretical approach, based on this investigation, was used to calculate the heat flow from the probe tip to the sample and then estimate the thermal conductivities at different scanning positions. Experimental results and theoretical calculation demonstrate that SThM can be used as a tool for the thermal property and microstructural analysis of ...
2006-06-15
Interpretation of gamma-scanning data from the ORR demonstration elements
Energy Technology Data Exchange (ETDEWEB)
The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.
1989-01-01
Study of the thermodynamic properties of (U,Ce)O{sub 2}
Energy Technology Data Exchange (ETDEWEB)
The X-ray diffraction analysis of (U,Ce)O{sub 2} with the CeO{sub 2} contents ranging from 0 to 20 mol% CeO{sub 2} was performed at room temperature to obtain the variation in the lattice parameter with the CeO{sub 2} content. Ultrasonic pulse echo measurements were also carried out to estimate the change in the mechanical properties of (U,Ce)O{sub 2} with the CeO{sub 2} content. The lattice parameter of (U,Ce)O{sub 2} was found to decrease with increasing CeO{sub 2} content. The variation in the lattice parameter with the CeO{sub 2} content closely followed the Vegard law. The shear and longitudinal velocities in (U,Ce)O{sub 2} were found to decrease with increasing CeO{sub 2} content. The Young`s and shear moduli, and Poisson`s ratio estimated from the wave velocities decreased with the CeO{sub 2} content. No mechanical property showed anomaly in low CeO{sub 2} content region. (orig.).
1997-08-01
Propagation of guided waves in aircraft structure
International Nuclear Information System (INIS)
The potential of ultrasonic guided modes for use in global structural health monitoring of aging metallic aircraft can only be realized if the modes selected are able to propagate over a reasonable distance. This work studies the propagation of different modes through fuselage structure by means of mode analysis, finite element modeling and experimental measurement. Beginning with the case of a simple skin panel, the paper examines propagation across a set of structural features representing a typical monocoque fuselage and considers the effect of overlying sealant layers, bonded and sealed joints, paint layers and tapering skin. With the exception of the fundamental symmetric mode at very low frequency, no mode was found that could propagate across all features with an effective attenuation of less than 40 dB/m. This makes global monitoring of a fuselage structure using a sparse array of transducers very difficult. However, more local monitoring is possible and ...
2000-05-23
Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea
Energy Technology Data Exchange (ETDEWEB)
An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed boundary layer. Both fast- ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
The results of these investigations can be summarised as follows: At simulated operating stress most naturally occuring faults in welded- and cast iron parts develop cracks and can be assessed for reliability under fatigue-,creep- and creep fatigue behaviour according to the laws of fracture mechanics. The empirically determined correlation between the real fault size and the ultrasonic inspection results (height of echo, echo dynamics, sound weakening) lead to better assessment of real fault extension in turbine components. It is very important to adapt the method of inspection and assessment to the type of possible fault.(orig.) [German] Die bei diesen Untersuchungen ermittelten Ergebnisse lassen sich wie folgt zusammenfassen: - Die Mehrzahl der untersuchten natuerlichen Fehlstellen in den Schmiede- und Gussstuecken verhalten sich unter den simulierten Betriebsbeanspruchungen rissartig und sind damit mittels den bruchmechanischen Gesetzen in ihrem ...
1998-07-01
Current status and future plan of JMTR Hot Laboratory
Energy Technology Data Exchange (ETDEWEB)
The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) nondestructive evaluation using ultrasonic wave and infrared thermography for the quantitative ...
1999-08-01
International Nuclear Information System (INIS)
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...
1998-02-01
Energy Technology Data Exchange (ETDEWEB)
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...
2004-09-01
Energy Technology Data Exchange (ETDEWEB)
Fatty acids such as stearic acid (SA), palmitic acid (PA), myristic acid (MA), and lauric acid (LA) are promising phase change materials (PCMs) for latent heat thermal energy storage (LHTES) applications, but high cost is the most drawback which limits the utility area of them in thermal energy storage. The use of fatty acids as form-stable PCM will increase their feasibilities in practical LHTES applications due to reduced cost of the energy storage system. In this regard, a series of fatty acid/poly(methyl methacrylate) (PMMA) blends, SA/PMMA, PA/PMMA, MA/PMMA, and LA/PMMA were prepared as new kinds of form-stable PCMs by encapsulation of fatty acids into PMMA which acts as supporting material. The blends were prepared at different mass fractions of fatty acids (50, 60, 70, 80, and 90% w/w) to reach maximum encapsulation ratio. All blends were subjected to leakage test by heating the blends over the melting temperature of the PCM. The blends that do not allow ...
2008-02-15
UK PubMed Central (United Kingdom)
Extending genome wide association analysis by the inclusion of gene expression data may assist in the dissection of complex traits. We examined piebald, a pigmentation phenotype in both human and Merino...Full Text Available
UK PubMed Central (United Kingdom)
The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available
2010-01-01
TO: All GCN Notice recipients RE
These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...
International Nuclear Information System (INIS)
English Oct 1996 p. 352-353 Brazil Maliska, Ana Maria Kuehn, Ingeborg Klein,
1996-10-01
UK PubMed Central (United Kingdom)
Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass...Full Text Available
2009-12-01
Spacecraft and Instruments - NASA
Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...
PrognoScan: a new database for meta-analysis of the prognostic value of genes
UK PubMed Central (United Kingdom)
BackgroundIn cancer research, the association between a gene and clinical outcome suggests the underlying etiology of the disease and consequently can motivate further studies. The...Full Text Available
Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults
UK PubMed Central (United Kingdom)
Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available
2010-03-01
Optical sectioning of microbial biofilms.
UK PubMed Central (United Kingdom)
Scanning confocal laser microscopy (SCLM) was used to visualize fully hydrated microbial biofilms. The improved rejection of out-of-focus haze and the increased resolution of SCLM made it preferable...Full Text Available
1991-10-01
UK PubMed Central (United Kingdom)
Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available
1981-05-01
Magnetic resonance imaging findings in 46 elbows with a radial head fracture
UK PubMed Central (United Kingdom)
Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available
2010-06-01
Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism
UK PubMed Central (United Kingdom)
BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available
2011-01-01
Lameness, Activity Time-Budgets, and Estrus Expression in Dairy Cattle
UK PubMed Central (United Kingdom)
The aim of the present study was to identify specific behavioral patterns that contribute to diminished estrus expression in lame cows. Behavioral scan and focal sampling were used to examine...Full Text Available
2008-12-01
Kaposi's sarcoma involving the thyroid in a patient with AIDS
International Nuclear Information System (INIS)
A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...
UK PubMed Central (United Kingdom)
The torque-velocity relationship is known to be affected by ageing, decreasing its protective role in the prevention of falls. Interindividual variability in this torque-velocity relationship is partly...Full Text Available
2008-09-01
Field experience with eddy current X-probes in CANDU steam generators and heat exchangers
Energy Technology Data Exchange (ETDEWEB)
CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...
2006-07-01
Field experience with eddy current X-probes in CANDU steam generators and heat exchangers
International Nuclear Information System (INIS)
CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...
2005-11-20
Energy Technology Data Exchange (ETDEWEB)
In the paper six cases of facial osteomyelitis as a complication of chronic sinusitis in hemophiliac-AIDS patients are reported. Osteomyelitis was suggested by an increasing of erythrocyte sedimentation rate. The diagnosis was confirmed by a positive {sup 99m} Tc MDP scintigraphy. The patients were submitted to clinical treatment. The erythrocyte sedimentation rate and 67-gallium citrate scans were used in the follow-up of the therapy. Three patients had negative gallium after three weeks of organism-specific antibiotic therapy; in two patients the gallium scintigraphy remained positive. One patient did not undergo the radionuclide scan for this clinical conditions. These results suggest that MDP scans showed higher sensitivity and specificity in detection of bone disease in chronic sinusitis. Gallium scans appeared to be valuable tool in the follow-up of the infection. There are no reports in the ...
1997-01-01
Experimental Electron Heat Diffusion in TJ-II ECRH Plasmas
Energy Technology Data Exchange (ETDEWEB)
Interpretative transport has been used to revisit the global scalings of TJ-II ECRH plasmas from a local perspective. Density, rotational transform and ERCH power scans were analysed based upon Thomson Scattering data (electron density and temperature) in steady state discharges. A simple formula to obtain the thermal conductivity, assuming pure diffusion and negligible convective heat fluxes was used in a set of 161 discharges. All the analysis was performed with the ASTRA transport shell. The density scan indicates that inside n=0,4 there is no significant change of e with density in the range studied (0.4 <ne>(1019m-3) 1.0), while in 0,5 <0,8 approximately, e decreases with density. In the rotational transform scan it is found that the values of e when a low order rational of the rotational transform is present locally seem to be smaller for the corresponding range, although it is apparent a general ...
2006-07-01
Electronic and Interfacial Properties of Pd/6H-SiC Schottky Diode ...
and palladium silicides (Pd,Si) with a total. AES intensity ratio of Pd to Si of 35/65. Scanning Electron Microscopy. (SEM') of the Pd region shows that ...
Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging
International Nuclear Information System (INIS)
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
UK PubMed Central (United Kingdom)
Thermal behaviors of eucalyptus wood residue (EWR) filled recycled high density polyethylene (HDPE) composites have been measured applying the thermogravimetric analysis (TGA) and differential scanning...Full Text Available
UK PubMed Central (United Kingdom)
Because the results with cobalt-57-bleomycin (57Co-bleo) as a tumour-seeking agent in patients with pulmonary tumours were promising, a prospective study was carried out to test the sensitivity and...Full Text Available
1976-12-01
Catheter Ablation for Paroxysmal Atrial Fibrillation
... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...
UK PubMed Central (United Kingdom)
Differential scanning calorimetric (DSC) studies of the glassy states of as-received and hydrated lysozyme, hemoglobin, and myoglobin powders, with water contents of < or = 0.25, < or...Full Text Available
1994-01-01
UK PubMed Central (United Kingdom)
The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available
1993-04-01
UK PubMed Central (United Kingdom)
PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available
2011-02-01
Atelectasis on pediatric chest CT: comparison of sedation techniques
International Nuclear Information System (INIS)
Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). ...
1999-07-01
An unusual presentation of metastatic adenocarcinoma of lung: a case report
UK PubMed Central (United Kingdom)
We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available
Amorphous to crystalline phase transformation in Metglas reg-sign studied by Moessbauer spectroscopy
International Nuclear Information System (INIS)
The authors present differential scanning calorimetry (DSC) and in situ Moessbauer spectroscopy results for Metglas ribbons, to which different heat treatments were made. The Curie temperature of the amorphous phase is determined and the evolution of the magnetic field of this phase is studied as a function of temperature
1997-12-01
UK PubMed Central (United Kingdom)
The lung of the lesser bushbaby (Galago senegalensis) has been investigated morphologically and morphometrically using the transmission and scanning electron microscopes. Grossly and microscopically,...Full Text Available
1990-10-01
A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT
UK PubMed Central (United Kingdom)
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
2010-01-01
Scintigraphic detection of a radiologically equivocal fracture
Energy Technology Data Exchange (ETDEWEB)
This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period.
1988-04-01
Scintigraphic detection of a radiologically equivocal fracture
International Nuclear Information System (INIS)
This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Primary B-cell lymphoma of thymus is uncommon. We describe the case of a 23-year-old woman with a history of shortness of breath and distended neck veins of 1-month duration. A chest roentgenogram and computed tomographic chest scan of the showed a large anterior mediastinal mass. Tru-cut biopsy revealed primary B-cell lymphoma of thymus. She underwent chemotherapy with no symptomatic improvement. Post-chemotherapy computed tomographic scan of the chest showed no appreciable reduction in tumor size. Surgical excision was carried out with excellent results.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
2011-01-01
International Nuclear Information System (INIS)
Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.
2009-11-25
International Nuclear Information System (INIS)
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only ...
1991-01-01
Multi-Phase Fracture-Matrix Interactions Under Stress Changes
Energy Technology Data Exchange (ETDEWEB)
The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several fractures have been ...
2005-12-07
Energy Technology Data Exchange (ETDEWEB)
This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the innovations presented here, applied alone or in ...
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
Fuel cells based on solid oxides ('SOFC') are excellent alternative devices for power generation, when they are operated at high temperature, e.g. above 600 C. Having only fixed parts for the power generating part of the device is only one advantage of the fuel cell. Due to their unique design, these devices offer a maximum of efficiency for energy conversion compared to conventional power generating systems, which are mainly based on turbines. One aim of this thesis is the examination of alternative electrolyte and cathode materials for the SOFC applications at reduced temperatures, which means in the temperature range between 600 C and 750 C. For the first main task, several materials from the oxygen ion conducting electrolytes were selected. Different strontium and magnesium doped lanthanum gallate (LSGM) materials with additional transition metal doping were selected and prepared via two different preparation methods. The optimum calcining ...
2007-05-04
International Nuclear Information System (INIS)
To investigate the effect of external loads arising from differential thermal expansion between a substrate and a surface-mount component during thermomechanical cycling, specimens with a nickel surface-mount component on a copper substrate were prepared. Specimens consisted of two 100 #mu#m thick 1 mm"2 solder joints about 9 mm apart, with two designs. In one specimen (denoted 'dual-shear'), the as-fabricated joints were not stressed due to differential contraction during solidification and cool down. In the other specimen (denoted 'component'), a continuous copper substrate between the joints caused the nickel component to be put in compression during cool down, which imposed shear on the joints. To impose differential thermal shear strains, the 'dual-shear' specimen was clamped to a copper block to cause a significant reversal in sign of the shear imposed on the solder joint during cycling. In the 'component' specimen configuration, the existing compressive strain in the component ...
2006-04-15
International Nuclear Information System (INIS)
Objective: To investigate the predictive value of ADC value in grading of neuroepithelial tumors. Methods: The clinical data and images of 70 patients with neuroepithelial tumors pathologically proven were collected and analyzed retrospectively. All the patients were classified into low (WHO I or II) and high (WHO III or IV) grade groups which included 40 and 30 cases respectively according to the 2007 WHO classification of tumours of the central nervous system. All the patients underwent plain and contrast-enhanced MR scan and DWI before surgery. The minimum ADC (MinADC) value was measured postoperatively on ADC maps. The Ki-67 labeling index (Ki-67 LI) of tumor tissue was determined by immunohistochemistry. MinADC values for two groups were analyzed using student t test, while the age and Ki-67 LI for the two groups was analyzed using Mann-Whitney test (P<0.05 considered to be significant). Also the MinADC value and Ki-67 LI were analyzed ...
2009-11-01
Energy Technology Data Exchange (ETDEWEB)
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB) [German] Bildgebende Verfahren kommen bei der Abklaerung von Erkrankungen des weiblichen Urogenitaltrakts ergaenzend zu der klinischen Untersuchung zur Anwendung. Kongenitale Uterusanomalien werden primaer mit der HSG oder der Laparoskopie diagnostiziert. Zusaetzlich koennen der transvaginale US und in unklaren Faellen die MRT eingesetzt werden. Die Diagnose entzuendlicher Erkrankungen des weiblichen Genitaltrakts erfolgt in der Regel klinisch. Schnittbildverfahren werden bei therapieresistenten, komplizierten Faellen angewendet. Initial werden benigne Neoplasien des Uterus mit dem transvaginalen US abgeklaert. Eine Verdickung des Endometriums ist dabei ein unspezifischer Befund und kann auf eine Hyperplasie, Polypen oder ...
2001-09-01
Prospective evaluation of femoral head viability following femoral neck fracture
International Nuclear Information System (INIS)
The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showed only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts ...
1984-06-05
Energy Technology Data Exchange (ETDEWEB)
A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...
1990-01-01
CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice
Energy Technology Data Exchange (ETDEWEB)
Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...
1992-07-15
CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice
International Nuclear Information System (INIS)
Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...
1992-07-01
The feasibility study of hot cell decontamination by the PFC spray method
International Nuclear Information System (INIS)
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Step-scan Fourier transform infrared spectroscopy in conjunction with impulse stress on polymer films has been used to monitor dynamic rheological responses in real time. A novel piezo-electrically-driven polymer microrheometer was employed to apply repetitive impulses to the polymer sample while time-domain spectra were recorded. Recent results include the study of both semi-crystalline polymers such as isotactic polypropylene (iPP) and elastomers such as Estane polyester/polyurethane copolymer and Kraton tri-block copolymer. The spectral changes of iPP are consistent with frequency-domain results. For iPP at room temperature, large differences in the response times of different absorption bands are not seen. However, the orientation response of the CH{sub 3} rocking mode is slightly slower than the responses of the backbone modes. To the authors` knowledge, this is the first reported successful step-scan FTIR time-domain dynamic polymer ...
1998-07-01
The uterine blush. A potential false-positive in Meckel's scan interpretation
Energy Technology Data Exchange (ETDEWEB)
To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. ...
1982-10-01
Position of nuclear-medical techniques for evaluation of loosened total hip endroprostheses
Energy Technology Data Exchange (ETDEWEB)
For diagnosis of loosening or infection after implantation of a single-side or double-side total hip endoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled leucocyte ...
1985-10-01
Energy Technology Data Exchange (ETDEWEB)
Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to ...
1989-12-15
Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin
Energy Technology Data Exchange (ETDEWEB)
The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled ...
1990-12-01
High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control
Energy Technology Data Exchange (ETDEWEB)
High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing ...
2004-03-31
Ganglioneuromas in childhood: MRI and CT characteristics
International Nuclear Information System (INIS)
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...
2000-05-01
Dimensionless energy confinement scaling in W7-AS
International Nuclear Information System (INIS)
Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is ...
1999-12-01
Computed tomography of the orbit
Energy Technology Data Exchange (ETDEWEB)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...
1981-01-01
Computed Tomography in pulmonary cystic fibrosis
International Nuclear Information System (INIS)
This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...
1984-11-01
[75Se]Selenomethionine scanning for parathyroid localization should be abandoned
International Nuclear Information System (INIS)
Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in the preoperative ...
Vessel elements present in the secondary xylem of Trochodendron and Tetracentron (Trochodendraceae)
British Library Electronic Table of Contents (United Kingdom)
For almost 150 years, the two monotypic genera Trochodendron and Tetracentron (Trochodendraceae) have been considered to share an unusual and primitive feature in angiosperms - the lack of vessels in their wood. Therefore, they have been classified in a basal position in the angiosperms. Our observations by light microscopy, low-vacuum environmental scanning electron microscopy (ESEM) and high-vacuum scanning electron microscopy (SEM) both in fresh and FAA-fixed materials consistently showed the presence of tracheary elements differentiated into two types in both genera. In Trochodendron, the tracheary elements can be divided into perforate vessel elements and imperforate fiber-tracheids and tracheids. The vessel elements show end and lateral walls. The pits on the end walls are elongate- ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Direct visualization of rare earths in @a- and @b-SiAlON unit-cells is performed through Z-contrast imaging technique in an aberration-corrected scanning transmission electron microscope. The preferential occupation of Yb and Ce atoms in different interstitial locations of @b-SiAlON lattice is demonstrated, yielding higher solubility for Yb than Ce. The triangular-like host sites in @a-SiAlON unit cell accommodate more Ce atoms than hexagonal sites in @b-SiAlON. We think that our results will be applicable as guidelines for many kinds of rare-earth-doped materials.
2011-01-01
Thermal and mechanical properties of poly(vinyl alcohol) plasticized with glycerol
British Library Electronic Table of Contents (United Kingdom)
Abstract Thermomechanical behavior of membranes based on blends of poly(vinyl alcohol) (PVA) with different weight percentage (wt %) of glycerol has been studied. Solid-state PVA/Glycerol polymer membranes were prepared by a solution casting method. The films were studied for thermal characteristics by differential scanning calorimetry (DSC) and thermogravimetric analysis and for the mechanical properties including hardness and modulus by nanoindentation method. The dispersion of glycerol within the polymer matrix was examined using scanning electron microscopy. Fourier transform infrared spectroscopy was used to confirm the formation of hydrogen bonding between the plasticizer and PVA in their blends and also to provide information on compatibility and physical interactions between the gl...
2011-01-01
Subdural effusions in children under two years. Clinical and computer-tomographical data
Energy Technology Data Exchange (ETDEWEB)
We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.
1980-05-01
British Library Electronic Table of Contents (United Kingdom)
Chitosan (Ch) microspheres have been developed by precipitation method, cross-linked with glutaraldehyde and used as a template for layer-by-layer (LBL) deposition of two natural polyelectrolytes. Using a LBL methodology, Ch microspheres were alternately coated with hyaluronic acid (HA) and Ch under mild conditions. The roughness of the Ch-based crosslinked microspheres was characterized by atomic force microscopy (AFM). Morphological characterization was performed by environmental scanning electron microscopy (ESEM), scanning electron microscopy (SEM) and stereolight microscopy. The swelling behaviour of the microspheres demonstrated that the ones with more bilayers presented the highest water uptake and the uncoated cross-linked Ch microspheres showed the lowest uptake capability. Micros...
2010-01-01
Precise measurement of a focused ion beam profile
Energy Technology Data Exchange (ETDEWEB)
The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.
1987-06-01
Polarised neutron reflectometry study of Co/CoO exchange-biased multilayers
Energy Technology Data Exchange (ETDEWEB)
We have investigated via SQUID magnetometry and polarised neutron reflectivity the exchange-bias effect in CoO/Co sputtered multilayers. In particular, we studied the magnetisation reversal and the time relaxation of the exchange-bias field close to the coercive field H{sub c1}. Neutron intensities of all four cross sections (I++, I+-, I-+, I-) were recorded at the position of the first multilayer Bragg peak while scanning the magnetic field. From such scans we infer that the magnetisation reversal for the ascending as well as for the descending branch of the magnetic hysteresis occurs not by in-plane rotation but through domain-wall movements. The exchange-bias field, H{sub EB}, is strongly affected by thermal fluctuations. H{sub EB} decreases, following an exponential decay function with a half-life time of about 580 s at T=240 K. (orig.)
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution and coverage of the ...
2000-11-01
Neutron intensity measurements of BWR spent fuels
International Nuclear Information System (INIS)
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
2000-03-01
Miscibility enhancement of PP/PBT blends with a side-chain liquid crystalline ionomer
British Library Electronic Table of Contents (United Kingdom)
Side-chain liquid crystalline ionomer (SLCI) containing sulfonic acid groups with a polymethylhydrosiloxane main-chain was used in the blends of polypropylene (PP) and polybutylene terephthalate (PBT) as a compatibilizer. The crystalline behavior, morphological, and mechanical properties of the blends were investigated in detail by differential scanning calorimetry (DSC), polarizing optical microscope (POM), Fourier transforms infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Revealed by the shift of Tm in DSC thermogram and the shift of the absorbed peak in FTIR spectra, specific interaction led to stronger interfacial adhesion between these phases, which resulted in much finer dispersion of the minor PBT phase in PP matrix. The SLCI containing sulfonate acid groups ac...
2009-01-01
Mechanism of filler action in reducing the wear of PTFE polymer by differential scanning calorimetry
British Library Electronic Table of Contents (United Kingdom)
Two types of representative nanometer materials, i.e., fibroid nanometer attapulgite and approximate spherical ultrafine diamond, were selected as fillers of polytetrafluoroethylene (PTFE) to study the mechanism of the wear-reducing actions of the fillers in PTFE composites. The friction and wear tests were performed on a block-on-ring wear tester under dry sliding conditions. Differential scanning calorimetry (DSC) was used to investigate material microstructure and to examine modes of failure. No significant change in coefficient of friction was found, but the wear rate of PTFE composites was orders of magnitude less than that of pure PTFE. DSC analysis revealed that nanometer attapulgite and ultrafine diamond played a heterogeneous nucleation role in PTFE matrix and consequently resulte...
2007-01-01
Impact of Cr3C2/VC addition on the dry sliding friction and wear response of WC-Co cemented carbides
British Library Electronic Table of Contents (United Kingdom)
Two grades of WC-10wt.%Co cemented carbide with or without addition of Cr3C2/VC grain growth inhibitor during liquid phase sintering were produced with the goal to investigate their reciprocating sliding friction and wear behaviour against WC-6wt.%Co cemented carbide under unlubricated conditions. The tribological characteristics were obtained on a Plint TE77 tribometer using distinctive normal contact loads. The generated wear tracks were analyzed by scanning electron microscopy and quantified topographically using surface scanning equipment. The post-mortem obtained wear volumes were compared to the online assessed wear. Correlations between wear volume, wear rate and coefficient of friction on the one hand and sliding distance and microstructural properties on the other hand were determ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.
1988-01-01
Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry
British Library Electronic Table of Contents (United Kingdom)
Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...
2010-01-01
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
British Library Electronic Table of Contents (United Kingdom)
Abstract Here we propose a software for the estimation of the occupied area and volume of fungal cultures. This software was developed using a Matlab platform and allows analysis of high-definition images from optical, electronic or atomic force microscopes. In a first step, a single hypha grown on potato dextrose agar was monitored using optical microscopy to estimate the change in occupied area and volume. Weight measurements were carried out to compare them with the estimated volume, revealing a slight difference of less than 1.5%. Similarly, samples from two different solid-state fermentation cultures were analyzed using images from a scanning electron microscope (SEM) and an environmental SEM (ESEM). Occupied area and volume were calculated for both samples, and the results obtained w...
2011-01-01
International Nuclear Information System (INIS)
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
Electrical properties of focused-ion-beam boron-implanted silicon
International Nuclear Information System (INIS)
Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).
Effects of modification on microstructure and properties of ultrahigh carbon (1.9wt.% C) steel
British Library Electronic Table of Contents (United Kingdom)
The effects of a modifier that contains Rare Earths (RE), low melting point alloy (Al-Bi-Sb) and Ca-Si alloy on an ultrahigh carbon steel containing 1.9wt.% C were studied. Microstructure characterization was carried out with optical microscopy (OM) and scanning electronic microscopy (SEM) combined with energy-dispersive spectrometry (EDS). Upon modification, the continuous eutectic carbide network structure was broken up and changed to a partly isolated and finer blocky structure in the as-cast alloy. Differential scanning calorimetry (DSC) revealed that the eutectoid temperature increased and the eutectic temperature decreased for the modified alloy. Modification also improved the impact toughness of the tempered steel, with a significant increase from 6.5 to 12.6Jcm^-^2, despite the har...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
To improve the friction and wear behavior of carbon fabric reinforced polymer composites (CFRP), nano-SiO2 was deposited on the fabric surface. The friction and wear behavior of the resulting composites were investigated on a model ring-on-block test rig. Experimental results revealed that fiber surface treatment contributed to largely improve the tribological properties of the CFRP composites. Scanning electron microscope (SEM) investigation showed that the worn surface of the surface modified CFRP composite was smoother under given load and sliding rate. Field emission scanning electron microscopy (FESEM), FTIR and X-ray photoelectron spectroscopy (XPS) studies of the carbon fiber surface showed that nanostructured Sio2 thin film can be obtained by SiO2 sols deposition, which improved th...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...
2011-01-01
Characterisation and use of biomass fly ash in cement-based materials
British Library Electronic Table of Contents (United Kingdom)
This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...
2009-01-01
Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics
International Nuclear Information System (INIS)
Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.
International Nuclear Information System (INIS)
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
We have employed Environmental Scanning Electron Microscopy (ESEM) and Energy Dispersive X-ray (EDX) analysis to study the microstructural evolution of acrylic latex stabilised with a novel polysaccharide derived from agricultural waste. The analysis revealed that the micro structure of the latex in the 'wet' state consists of individual particles and clusters. Upon evaporation a discontinuous film is formed, with voids present within its structure, which is inconsistent with the conventional descriptions of film formation. Further ESEM examination of 'dry' specimens revealed that aging resulted in the formation of dendritic structures on the surfaces of the latex films, which EDX analysis confirmed to have been formed via crystallisation of salt. The experimental evidence suggests that the clusters, which are part of the structure of the latex, may act as nucleation centres that would allow the dendrites to form.
2008-08-15
A digitization and multimedia project at Quinnipiac University, Hamden, Connecticut, USA
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...
2007-01-01
Collaborative systems and multiagent systems
This paper presents some basic elements regarding the domain of the collaborative systems, a domain of maximum actuality and also the multiagent systems, developed as a result of a sound study on the one-agent systems.
2009-01-01
Turbine blade protective coat damage; Schutzschichtschaeden an Gasturbinenschaufeln
Energy Technology Data Exchange (ETDEWEB)
Damage survey of protective coats of modern gas turbine blade shows that most damages are not due to classic wear mechanisms such as oxydation or high-temperature corrosion but caused by foreign bodies, poor coating during manufacturing, or operation-caused cracks. Mere visual inspection of cracks is often not sufficient to tell whether cracks are superficial or whether they have already progressed into the base material. Non-destructive methods such as ultrasonic inspection or eddy-current testing are helpful tools but there is not yet a fully matured testing concept at hand. Metallographical tests can give important information about crack mechanisms and thermal, chemical and mechanical stresses.(orig.) [German] Die Schadenerfahrung mit Schutzschichten moderner Gasturbinenschaufeln zeigt, dass die meisten Schaeden nicht auf die klassischen Verbrauchsmechanismen wie Oxydation und Hochtemperaturkorrosion zurueckzufuehren sind, sondern durch Fremdkoerper, ...
1998-07-01
Top of tubesheet cracking in Bruce A NGS steam generator tubing - recent experience
Energy Technology Data Exchange (ETDEWEB)
During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary side and primary side initiated, circumferential, stress corrosion cracking and intergranular attack ...
1998-07-01
Steam Generator Group Project: Annual report, 1985
Energy Technology Data Exchange (ETDEWEB)
This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is discussed. Successful ...
1987-04-01
Steam Generator Group Project: Annual report, 1985
International Nuclear Information System (INIS)
This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is discussed. Successful ...
Predictive maintenance plant assessment
Energy Technology Data Exchange (ETDEWEB)
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leak detection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or some of these technologies can be staggering, not to mention the ...
1996-07-01
International Nuclear Information System (INIS)
Alloys of zirconium are widely used in various core components of power reactors. Nuclear assemblies require high degree of reliability and integrity for performing in radiation and corrosive atmosphere. The hostile environments of reactor core and inaccessibility for repairs make it mandatory to select only those joining techniques which produce not only superior quality but are also amenable to NDT methods and such other techniques which ensure acceptable performance. The author has worked on various types of welding of zirconium alloys for different applications. Modern techniques in electron beam (EB) welding, resistance welding, GTAW welding and laser welding have been developed for joining Zr alloys components for different types of reactors. Many of these have been standardized and successfully used in production. Several advancements have been made in the welding technologies towards achieving high productivity and increased reliability with economy and adaptability. EB, laser, ...
2002-09-11
International Nuclear Information System (INIS)
Objective: To survey the data for the state of health in the ambient residents of Daya Bay Nuclear Power Plant, and provide the background data to evaluate the state of health affected by fallout of nuclear power plant. Methods: The datas were collected by a radiation epidemiology. The investigation was carried out in the area within 20 km of radius from Daya Bay Nuclear' Power Plant, and the subjects who had lived there for three years or longer before January. 1,1993 and covered by the Household Registry were recruited to a cohort. Results: The mortality rate of overall cancer (per 100 000 PYr) was 88.57 (the standard mortality rate was 79.77 ), the mortality rate of leukemia (per 100 000 PYr) was 3.24 (the standard mortality rate was 2.94), the palpation rate of the goiter in 7-14 years old was 8.34%(9.69% in B ultrasonic), the morbidity rate of newborn's defect (per 100 00 P) was 82.33. The mortality of all cancers or leukemia was similar to the result from ...
2005-06-01
International Nuclear Information System (INIS)
Under the current design philosophy, reactor structures are to be designed to withstand large inelastic deformation caused by strong and severe ground motion. The design of the main structural elements and their connections are to be such that they always fail in ductile mode. This will ensure large energy absorption capacity of the structures under seismic excitation and avoid sudden and brittle failure of the structure. Over the years, a number of experimental investigations have been carried out on RC beam- column joints to study their behaviour and strength. However, these studies mostly pertain to small scale joints of moment resisting frame of residential buildings and commercial complexes. Information on full scale joints existing in NPP structures are scanty. Therefore, experimental programme was planned in the laboratory to construct identical large sized joints with the same reinforcement percentage and detail as that of the existing joints in NPP structures built in 1960's. ...
2003-02-01
International Nuclear Information System (INIS)
A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio F-test; no significant ...
2004-06-04
VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
Energy Technology Data Exchange (ETDEWEB)
The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did ...
1988-12-01
Regulatory T cells inhibit stable contacts between CD4+ T cells and dendritic cells in vivo
UK PubMed Central (United Kingdom)
Regulatory T (T reg) cells exert powerful down-modulatory effects on immune responses, but it is not known how they act in vivo. Using intravital two-photon laser scanning microscopy we determined that,...Full Text Available
2006-03-20
Radioisotope imaging of brain tumors in two rhesus monkeys. Final report
Energy Technology Data Exchange (ETDEWEB)
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
1988-04-01
Fouling Study of Silicon Oxide Pores Exposed to Tap Water
Energy Technology Data Exchange (ETDEWEB)
We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.
2007-07-12
Fault diagnosis of rolling bearing based on cyclic spectrum density
International Nuclear Information System (INIS)
The paper considered the vibration signals of rotating equipment as cyclo stationary signals through analyzing the features of this kind of signals. Based on the analytic method of cyclic spectrum density, the paper pointed out that the impact frequency could be extracted effectively with the help of scanning cyclic frequency domain. The validity of the method of cyclic spectrum density is proved by simulating signals and the method is applied to the diagnosis of rolling bearings. (authors)
2009-09-01
Effect of environmental variables on localized corrosion of high-performance container materials
Energy Technology Data Exchange (ETDEWEB)
Electrochemical cyclic potentiodynamic polarization (CPP) experiments were performed on several candidate high-performance waste package container materials to evaluate their susceptibility to localized corrosion in aqueous environments relevant to the potential underground high-level nuclear waste repository. This paper presents the results of this study showing the effects of chloride ion (Cl) concentrations, pH, temperature, and electrochemical potential scan rate on the pitting corrosion behavior of these materials.
1997-01-01
Differential diagnosis of tumorous lesions in the iliac bone in children
Energy Technology Data Exchange (ETDEWEB)
The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.
1984-02-01
Dielectric barrier discharge using corona-modified silicone rubber
Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.
2008-10-01
Data of spleen-scintiscanning after splenectomy
International Nuclear Information System (INIS)
In 65 adult rabbits of both sexes (2.5 to 6 kg) the following salvaging procedures were performed after simulated trauma: (1) Continuous suture line; (2) closure with fibrin sealant after temporary clamping; (3) hemisplenectomy with omental wrap; (4) suture fixation of fragments and slices of spleen tissue to the peritoneum; (5) suture fixation of spleen fragments to the omentum; (6) extraperitoneal subcutaneous transposition of spleen cubes. In addition, the likelihood of spontaneous splenosis was examined in a preliminary study involving 5 animals by introducing unattached spleen meal and fragments. Scanning was repeated 4 to 12 weeks postoperatively. The functional competence of minor parenchymal islands was also investigated with well counter measurements of organ and muscle tissue homogenates. Spontaneous splenosis after abdominal injuries was not found to be the rule. Salvaging procedures at the natural vascular hilus by sutures, fibrin sealant and ...
Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method
Energy Technology Data Exchange (ETDEWEB)
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
1982-01-01
CT scan findings in cerebral paragonimiasis
International Nuclear Information System (INIS)
Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
1982-01-01
CT manifestations of ileal dysgenesis
Energy Technology Data Exchange (ETDEWEB)
Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)
2007-02-15
Biodegradability of polyurethane/polysaccharide blends
Energy Technology Data Exchange (ETDEWEB)
Biodegradable polymers for use in environmental waste-management has been the subject of much discussion over the last few years. Polyurethane mixtures with polysaccharide (80/20 and 90/10 w/w ) have been prepared and films obtained. These films were inoculated, according to ASTM G22-76 rule and analysed by thermogravimetry and scanning electronic microscopy (SEM). The results are discussed in terms of thermal degradation and biodegradability. (author)
2001-07-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
International Nuclear Information System (INIS)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the ...
2009-03-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the ...
2007-06-15
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
