WorldWideScience
1

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 ...

2009-07-20

3

Study of the thermodynamic properties of (U,Ce)O{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The X-ray diffraction analysis of (U,Ce)O{sub 2} with the CeO{sub 2} contents ranging from 0 to 20 mol% CeO{sub 2} was performed at room temperature to obtain the variation in the lattice parameter with the CeO{sub 2} content. Ultrasonic pulse echo measurements were also carried out to estimate the change in the mechanical properties of (U,Ce)O{sub 2} with the CeO{sub 2} content. The lattice parameter of (U,Ce)O{sub 2} was found to decrease with increasing CeO{sub 2} content. The variation in the lattice parameter with the CeO{sub 2} content closely followed the Vegard law. The shear and longitudinal velocities in (U,Ce)O{sub 2} were found to decrease with increasing CeO{sub 2} content. The Young`s and shear moduli, and Poisson`s ratio estimated from the wave velocities decreased with the CeO{sub 2} content. No mechanical property showed anomaly in low CeO{sub 2} content region. (orig.).

1997-08-01

4

Structural studies of some phospho-borate glasses using ultrasonic pulse-echo technique, DSC and IR spectroscopy  

International Nuclear Information System (INIS)

Glasses in the system (95-x) [0.25 Na2O-0.75 B2O3]-x P2O5-5 Fe2O3 (0?x?15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P2O5 on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P2O5. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P2O5 content as a second network former. These results are interpreted in terms of the replacement of the diborate units with B-O-B bridges by phosphate units with non-bridging oxygens (NBOs). Therefore, ...

2009-06-01

5

Observations of photon echo enhancement in an ultraslow light regime  

CERN Document Server

Using spectral hole-burning-based ultraslow group velocity in a dilute solid medium, we report enhanced photon echo efficiency three orders of magnitude higher than that in a nonslow light regime. The enhancement is due to exponentially increased absorption of an optical data pulse owing to the enhanced photon-atom interaction in an ultraslow light regime, whereas echo reabsorption is negligibly small due to group-velocity dependent population depletion.

2011-01-01

6

Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy  

International Nuclear Information System (INIS)

The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is ...

2009-10-12

7

Structural studies of some phospho-borate glasses using ultrasonic pulse-echo technique, DSC and IR spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Glasses in the system (95-x) [0.25 Na{sub 2}O-0.75 B{sub 2}O{sub 3}]-x P{sub 2}O{sub 5}-5 Fe{sub 2}O{sub 3} (0<=x<=15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P{sub 2}O{sub 5} on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P{sub 2}O{sub 5}. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P{sub 2}O{sub 5} content as a second network former. These results are interpreted in terms of the replacement of ...

2009-06-01

8

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

9

Measurement of the susceptibility of solid "3He along the melting curve from 20 mK down to the nuclear ordering temperature  

International Nuclear Information System (INIS)

The susceptibility of solid "3He is deduced from multiple echoes observed in pulsed NMR experiments. It follows a Curie Weiss law at high temperature, increases faster than this law below 5 mK and drops abruptly around 1 mK. (Auth.).

1977-02-01

10

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

11

Fault assessment in large welded- and cast iron parts; Fehlerbeurteilung in grossen Schmiede- und Gussteilen  

Energy Technology Data Exchange (ETDEWEB)

The results of these investigations can be summarised as follows: At simulated operating stress most naturally occuring faults in welded- and cast iron parts develop cracks and can be assessed for reliability under fatigue-,creep- and creep fatigue behaviour according to the laws of fracture mechanics. The empirically determined correlation between the real fault size and the ultrasonic inspection results (height of echo, echo dynamics, sound weakening) lead to better assessment of real fault extension in turbine components. It is very important to adapt the method of inspection and assessment to the type of possible fault.(orig.) [German] Die bei diesen Untersuchungen ermittelten Ergebnisse lassen sich wie folgt zusammenfassen: - Die Mehrzahl der untersuchten natuerlichen Fehlstellen in den Schmiede- und Gussstuecken verhalten sich unter den simulierten Betriebsbeanspruchungen rissartig und sind damit mittels den ...

1998-07-01

12

Dynamically focussed array  

Energy Technology Data Exchange (ETDEWEB)

An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a continuously varying ...

1981-07-07

13

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue ...

2008-05-07

14

THE EFFECTS OF ONE MEGACYCLE ULTRASONIC ...  

Science.gov (United States)

... ULTRASONIC VIBRATION TO PORTLAND CEMENT-WATER PASTE REDUCES THE ULTIMATE COMPRESSIVE STRENGTH OF MORTARS ...

1959-09-09

15

New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging  

International Nuclear Information System (INIS)

A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.

16

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global ...

2004-01-01

18

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those obtained for the artificially defected tube. In ...

19

An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.  

Science.gov (United States)

A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for systems ...

2010-07-19

20

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of ...

2004-07-01

21

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

23

Repair of a Complex Congenital Cardiac Defect  

Medline Plus

... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...

26

Prediction of the intramuscular fat content in loin muscle of pig carcasses by quantitative time-resolved ultrasound  

British Library Electronic Table of Contents (United Kingdom)

A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...

2012-01-01

27

Physical properties of Ti/sub 50/Be/sub 40/Zr/sub 10/ glass  

Science.gov (United States)

Continuous metallic glass ribbons were produced by mejans of liquid-quenching at rates >10/sup 50/C/s. The ribbons, typically 30 ..mu..m thick and 1 to 2 mm wide, were determined to be glassy by X-ray diffraction (XRD) employing CuK..cap alpha.. and MoK..cap alpha.. radiation. Mechanical properties of the as-quenched product were determined by measurements of hardness, tensile strength and Young's modulus. The Vicker's diamond pyramid microhardness (H/sub V/) was measured on epoxy mounted samples using a Lietz Miniload instrument with a 100 g load. Tensile tests were conducted in an Instron machine using specimens which were hand-polished to produce smooth, parallel sides. Young's modulus (E) is given by the relationship rho V/sub E/sup 2//. V/sub E/, the velocity of extensional mode waves, was measured by the pulse-echo technique using a Panametrics Intervalometer and glass density, rho, was obtained by the liquid immersion method. ...

1977-09-01

28

Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998  

Energy Technology Data Exchange (ETDEWEB)

Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout that were investigated include bleeding, shrinkage, bond strength, freeze-thaw ...

1998-11-01

30

Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep ...

1997-04-01

31

Theory of NMR multiple echoes in solid hydrogen  

Energy Technology Data Exchange (ETDEWEB)

We have examined the theory of NMR multiple echoes developed for solid {sup 3}He to determine whether multiple echoes could be observed in solid hydrogen. We were particularly interested in the possibility of testing for low frequency quantum tunneling motions in solid hydrogen by the observation of multiple echoes. We find that for easily accessible nuclear spin polarizations, P > 12%, multiple echoes would be observed for HD impurities in solid parahydrogen if motional narrowing is effective in increasing the HD nuclear spin-spin relaxation time T{sub 2} to the order of 1 msec. These values for T{sub 2}, which have been observed for HD impurity concentrations of the order of 1%, are larger than the calculated rigid lattice values and can be attributed to quantum tunneling at frequencies of the order of 1kHz.

1995-11-01

32

Ultrasonic Acoustic Emissions from the Sapwood of Cedar and Hemlock 1  

UK PubMed Central (United Kingdom)

Measurements are reported of ultrasonic acoustic emissions (AEs) measured from sapwood samples of Thuja occidentalis L. and Tsuga canadensis (L.) Carr. during air dehydration....Full Text Available

1984-08-01

33

Ultrasonic enhancement of heat transfer on narrow surface  

Energy Technology Data Exchange (ETDEWEB)

Ultrasonic enhancement of heat transfer on a narrow surface was measured by changing the width of the surface from 8 to 0.1 mm. Ultrasonic power of 600 W with a frequency of 40 kHz was used. Heat transfer on the narrow surface without ultrasonic vibration was correlated by the experimental equation for a thin wire. The cavitation intensity was measured by the cavitation erosion loss of an aluminum foil of 15 [mu]m thickness. The effects of acoustic streaming and cavitation were separated by this measurement. Heat transfer by acoustic streaming was predicted through forced convection. Enhancement by cavitation was explained by the turbulence thermal conductivity of the microjets.

1994-06-01

34

Evaluation of ultrasonic indications in steam turbine rotors by fracture mechanics analysis  

International Nuclear Information System (INIS)

The report summarizes ten years of experience in the analysis and evaluation of ultrasonic testing data measured in turbine and generator rotors. Apart from the information on type, position, size and distribution of flaws, the expert knowledge achieved in an interpretation of ultrasonic signals yields further insight, as e.g.: - Confirmation of assumptions taken as a basis for fracture-mechanical analysis of these flaws with regard to crack initiation and crack growth under low-cycle fatigue conditions (O=0.7-1 Rp 0.2, N<25.000 growth in length); - enhanced information on a correlation of ultrasonic testing data with the real flaw size. (orig.).

1990-10-04

35

Ultrasonic piezoelectric transducer that forms a specified directivity pattern  

Energy Technology Data Exchange (ETDEWEB)

Methods of designing ultrasonic piezoelectric transducers in accord with a specified directivity pattern are analyzed and general formulas are presented for the design problem. As an example, the pressure distribution on the working surface of a circular piezoelectric transducer is determined that is capable of forming a narrow weakly divergent beam. Experimental results are presented with respected to ultrasonic fields that support the theoretical conclusions.

1989-03-01

36

Evaluation of phased array UT conditions using ultrasonic visualization technique  

International Nuclear Information System (INIS)

Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)

2008-07-01

37

Effect of ultrasonic waves on boiling heat transfer. 2  

International Nuclear Information System (INIS)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-05-01

38

Effect of ultrasonic waves on boiling heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-07-01

39

Effect of ultrasonic energy on Mn-Zn ferrite powder behavior  

Energy Technology Data Exchange (ETDEWEB)

Effect of ultrasonic-wave irradiation on the Mn-Zn ferrite powder suspension prepared by solid-state reaction and alcoholic dehydration methods was investigated. Size, distribution, and morphology of the powders prepared at different temperatures were examined, as a function of irradiation time. It was observed that the powders were reduced in size by ultrasonic energy through distinct routes. 8 refs., 7 figs., 1 tab.

1999-07-01

40

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity variation with repetition and T1 relaxation time ...

2001-03-01

41

A high accuracy ultrasonic measurement method for nondestructive evaluation of residual stress in welded pipings  

Energy Technology Data Exchange (ETDEWEB)

Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The ...

1995-08-01

42

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is ...

43

Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil  

Energy Technology Data Exchange (ETDEWEB)

Single-shot spin-echo diffusion-weighted echo-planar imaging using a phased-array multicoil was performed to distinguish between normal and cirrhotic livers. Sets of 6 images with different b-value were acquired with breath-holding. Significant differences were observed between controls and cirrhosis cases in the signal ratios when the b-value was 383 s/mm{sup 2}, and apparent diffusion coefficients. (orig.)

1998-07-01

44

Resonance spin-echo option on neutron reflectometers for the study of dynamics of surfaces and interfaces  

Energy Technology Data Exchange (ETDEWEB)

The applications of neutron reflectometry to study dynamic phenomena at surface and interfaces have been restricted so far. This was mainly due to the low intensity of neutron sources, but now high-intensity spallation neutron sources are under construction in Japan (J-PARC) and US (SNS). We are planning to install a spin-echo option on the J-PARC neutron reflectometer with horizontal sample geometry for studies of dynamics of surfaces and interfaces. This option is based on the resonance spin-echo method and aimed at dynamics up to hundreds of nanoseconds. In this contribution, the plan and status of development are introduced together with the principle and characteristics of this option.

2005-02-15

45

Vibrational population dynamics in liquids and glasses: IR pump-probe experiments from 10 K to 300 K  

Energy Technology Data Exchange (ETDEWEB)

The temperature dependent vibrational relaxation of the CO stretching mode of Rhodium dicarbonyl acetylacetonate (Rh(CO){sub 2}(acac)) and tungsten hexacarbonyl (W(CO){sub 6}) in dibutylphthalate (DBP) and 2-methylpentane (2-MP) were measured with IR pump and probe (P-P) experiments. The experiments were performed with {approximately}1.5 ps pulses generated by the Stanford superconducting accelerator pumped free electron laser (FEL). Measurements were performed on the Rh(CO){sub 2}(acac) CO asymmetric stretching mode at {lambda} = 4.98{mu}m from 10 K to 300 K. Both the parallel and magic angle probe polarizations decay curves are biexponential over the entire temperature range. The slow component (ranging from 40 ps at 300 K to 55 ps at 10K) is attributed to the population relaxations. For the fast component (ranging from 4-5 ps at 300 K to 13-15 ps at 10K), we propose a mechanism of spectral diffusion, in contrast to the previously proposed mechanisms of ...

1995-12-31

46

Appearance of normal brain maturation on 1.5-T MR images  

International Nuclear Information System (INIS)

To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of myelination, as demonstrated by histochemical methods. T1-weighted images were most useful ...

47

Acid/base and hydrogen bonding effects on the proton-coupled electron transfer of quinones and hydroquinones in acetonitrile: Mechanistic investigation by voltammetry, "1H NMR and computation  

International Nuclear Information System (INIS)

This report seeks to address the role of hydrogen bonding with Bronsted acids and bases in proton-coupled electron transfer (PCET) as it pertains to concerted or stepwise pathways of quinone (Q) and hydroquinone (QH_2) electrochemistry. This study was performed using a series of techniques that included cyclic voltammetry (CV), digital simulations, computational chemistry and "1H NMR. Hydrogen bonding was inferred by a decrease in diffusion coefficient (D) values measured using a pulsed gradient echo- (PGE-) "1H NMR technique. Changes of 40.8% and 37.9% in D values were only noted after the addition of two equivalents of acetate to 1,4-hydroquinone (1,4-QH_2) and catechol (1,2-QH_2), respectively. In contrast, the D values for the addition of selected amines (pyridine, N,N-diisopropylethylamine and triethylamine) changed only 3.2% on average. Quantum mechanical calculations were conducted to determine the pK_a of all quinoid species to serve as ...

2010-09-01

48

View Datasets - ECHO - NASA  

Science.gov (United States)

This data set contains data from in situ infrared thermometer measurements ... Surface temperature was measured using an Apogee Infrared Thermometer from 23 ...

50

Joining of zirconium alloys  

International Nuclear Information System (INIS)

Alloys of zirconium are widely used in various core components of power reactors. Nuclear assemblies require high degree of reliability and integrity for performing in radiation and corrosive atmosphere. The hostile environments of reactor core and inaccessibility for repairs make it mandatory to select only those joining techniques which produce not only superior quality but are also amenable to NDT methods and such other techniques which ensure acceptable performance. The author has worked on various types of welding of zirconium alloys for different applications. Modern techniques in electron beam (EB) welding, resistance welding, GTAW welding and laser welding have been developed for joining Zr alloys components for different types of reactors. Many of these have been standardized and successfully used in production. Several advancements have been made in the welding technologies towards achieving high productivity and increased reliability with economy and adaptability. EB, laser, ...

2002-09-11

51

THE APPLICATION OF STEEP PULSE CURRENTS TO THE ...  

Science.gov (United States)

... Title : THE APPLICATION OF STEEP PULSE CURRENTS TO THE ELECTROHYDRAULIC AND MAGNETIC FORMING OF METALS. ...

1966-04-01

52

Prestin and high frequency hearing in mammals  

UK PubMed Central (United Kingdom)

Recent evidence indicates that the evolution of ultrasonic hearing in echolocating bats and cetaceans has involved adaptive amino acid replacements in the cochlear gene prestin. A substantial...Full Text Available

2011-03-01

53

Intravesical Prostatic Protrusion in Men in Olmsted County, Minnesota  

UK PubMed Central (United Kingdom)

PurposeUltrasonically measured intravesical prostatic protrusion may be a promising noninvasive method of assessing bladder outlet obstruction. Previous investigations...Full Text Available

2009-12-01

54

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)

2002-03-01

55

Automated NDT for large diameter tubular products  

International Nuclear Information System (INIS)

Ultrasonic and eddy-current techniques are used to automatically examine large diameter tubular products during their production for defective areas and out-of-tolerance conditions.

1976-09-06

56

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure ...

2005-08-15

57

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. ...

58

MR imaging of bone marrow with gradient echo sequences. Pt. 1. Contrast conditions of phase-identical and opposed-phase gradient echo sequences. Kernspintomographische Screeninguntersuchungen des Knochenmarkes mit Gradientenecho-Sequenzen. T. 1. Kontrastverhaeltnisse phasenidentischer und phasenverschobener Gradientenecho-Sequenzen. Untersuchungen von Probanden und pathologisch-anatomischen Praeparaten  

Energy Technology Data Exchange (ETDEWEB)

Anatomical specimens and normal persons were studied by gradient echo MR imaging to determine the influence of different echo times (TE) on bone marrow contrast. First of all, six normal persons were studied to determine specific echo times for in-phase and opposed-phase states. Using different sequences bone marrow contrast in isolated femoral bones was determined and compared to results of pathological exams. Red bone marrow had no signal on opposed-phase images; contrast between red and yellow marrow was higher on opposed-phase than on in-phase images. Bone marrow lesions can be expected to be visualised with high signal on opposed-phase images; this technique should be especially suited for MR imaging of bone marrow. (orig.).

1991-06-01

59

Stress measurement and bolt tensioning by ultrasonic methods  

International Nuclear Information System (INIS)

In the past decade, a new technique has been developed for measuring tensile stresses in solids. This ultrasonic technique has been used thus far primarily for measuring fastener tension. The precision of measurement is routinely to 2-3% and, with special care, to approx. 1%. The method is insensitive to the frictional losses which plague tensioning by torque wrench. Though the approach is relatively new, it promises a wide range of applicability.

1980-01-01

60

Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials  

International Nuclear Information System (INIS)

It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.

2007-12-17

61

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

62

Localized H-1 MR spectroscopy in postnatal brain development  

International Nuclear Information System (INIS)

This paper investigates regional and age-related changes in metabolite ratios using image-localized H-1 MR spectroscopy in children. Twenty-seven children referred for MR imaging of the brain underwent localized H-1 MR spectroscopy with a Siemens 1.5-T whole-body imager. Localization to 2 x 2 x 2-cm volumes of interest was achieved with a stimulated-echo or spin-echo technique. Repetition times of 1,600 and 5,000 msec were used, with echo times varying between 68 and 270 msec. Total combined imaging and spectroscopy times were 90-120 minutes.

1990-11-25

63

Aircraft measurements of asymmetric temperature microstructure causing azimuth variations of VHF radar echo power  

British Library Electronic Table of Contents (United Kingdom)

VHF wind-profiling radars often measure a decrease of echo power with zenith angle, which can be explained from in situ measurements of horizontal layering or anisotropy of metre-scale temperature structure in the atmosphere. There can also be an azimuthal variation of echo power, which is increased in an azimuth opposite to the vertical shear vector of horizontal wind. This paper checks if the azimuth variation can also be linked to in situ observations of temperature structure, using aircraft flights in the tropopause region near a VHF radar. At heights where VHF radar measures wind shear and aspect sensitivity, there can be an asymmetry in the probability distribution of horizontal gradient of potential temperature, for horizontal scale of e.g. hundreds of metres. The asymmetry is often...

2007-01-01

64

Acute femoral neck fracture  

International Nuclear Information System (INIS)

Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).

67

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE); Ein neuer Ansatz in der Magnetresonanztomographie der Lunge mit einer ultrakurzen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, ...

1996-05-01

68

Ultrasonic Acoustic Emissions from the Sapwood of Thuja occidentalis Measured inside a Pressure Bomb 1  

UK PubMed Central (United Kingdom)

An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available

1984-04-01

69

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

70

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

71

Generation and control of sound bullets with a nonlinear acoustic lens  

UK PubMed Central (United Kingdom)

Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available

2010-04-20

72

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for ...

2009-07-01

73

Results of UT training for defect detection and sizing technique using specimens with fatigue crack and SCC  

International Nuclear Information System (INIS)

At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)

2005-04-01

74

BURST STRENGTH AND NON-DESTRUCTIVE EVALUTION OF COMPOSITE PIPES AND PIPE COUPLINGS WITH DEFECTS (TOP 48)  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...

1996-01-31

75

In vitro investigation of biological and technical prosthetic heart valves in MRI: evaluation of possible deflection and heating of the implants; In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung moeglicher Anziehung und Erhitzung der Implantate  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: ...

2000-02-01

76

Optimized pulse sequences for the suppression of decoherence in quantum information  

International Nuclear Information System (INIS)

The dynamical decoupling (DD) aims at suppressing the decoherence by means of coherent control pulses. Even if devices exist where instantaneous pulses are an adequate approximation, experimentally a finite duration #tau#_p and a bounded amplitude are inevitable. They are the cause of additional errors which can be corrected by designing the pulse shape appropriately. The new pulse has the overall effect of an ideal, instantaneous pulse with the advantage of decoupling the spin (or qubit) from the bath up to the order O(#tau#_p"3). The limitation of the no-go theorem for #pi# pulses is avoided. Hence, the Uhrig sequence (UDD), originally thought for ideal #pi# pulses, works also for bounded control Hamiltonians. Numerical simulations show that concatenated sequences of real pulses are effective against general ...

2010-03-21

77

Principle of pulse frequency measurement and methods for improving frequency meters accuracy  

Energy Technology Data Exchange (ETDEWEB)

Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed.

1980-01-01

78

Principle of pulse frequency measurement and methods for improving frequency meters accuracy  

International Nuclear Information System (INIS)

Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed. (author).

1980-01-01

79

A TUNNEL DIODE UNIVIBRATOR AND PULSE HEIGHT DISCRIMINATOR  

Science.gov (United States)

A univibrator and a pulse height discriminator using tunnel diodes and backward diodes are described, along with their applications in pulse shaping and fast coincidence technique. The main advantages achieved are simplicity of design and speed. The characteristics of the two diodes are shown. (auth)

1961-03-01

80

Sorption equilibrium and hydration studies of lysozyme: water activity and 360-MHz proton NMR measurement  

International Nuclear Information System (INIS)

An attempt to determine lysozyme hydration by employing a proton nuclear magnetic resonance (NMR) spin-echo technique and to correlated such measurements with the 20 "0C sorption equilibrium data is made. Determinations of specific site hydration for lysozyme, as well as proton NMR transverse relaxation rates for five different types of water populations in the lysozyme-water system, are presented over the whole range of lysozyme concentrations. The proton spin-echo NMR results are consistent with a three-component analysis of the sorption isotherm up to 70% water content, above which two additional water populations are identified by 360-MHz proton NMR spin-echoes. On the basis of the proton NMR results, a major component (III) of the lysozyme sorption isotherm is assigned to the water trapped between lysozyem molecules, whose relaxation rate is increased by diffusion barriers. The trapped water population dominates the ...

81

Vascular Effects of Photodynamic and Pulsed Dye Laser Therapy Protocols  

UK PubMed Central (United Kingdom)

Background and ObjectivePulsed dye laser (PDL) treatment of cutaneous vascular lesions is associated with variable and unpredictable efficacy. Thus, alternative treatment...Full Text Available

2008-11-01

82

Development of High Field Dipole and High Current Pulse Power Supply for Compact Proton Synchrotron  

CERN Document Server

Development of High Field Dipole and High Current Pulse Power Supply for Compact Proton Synchrotron

2003-01-01

83

Chinese Journal of Lasers (Selected Articles)  

Science.gov (United States)

... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...

1991-12-10

84

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

86

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

87

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

88

Learning material defect patterns by separating mixtures of independent component analyzers from NDT sonic signals  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces the application of independent component analysis mixture modelling (ICAMM) in non-destructive testing (NDT). The application consists of discriminating patterns for material quality control from homogeneous and defective materials inspected by impact-echo testing. This problem is modelled as a mixture of independent component analysis (ICA) models, representing a class of defective or homogeneous material by an ICA model whose parameters are learned from the impact-echo signal spectrum. These parameters define a kind of particular signature for the different defects. The proposed procedure is intended to exploit to the maximum the information obtained with the cost efficiency of only a single impact. To illustrate this capability, four levels of classification detail...

2010-01-01

89

Decoherence, entanglement decay, and equilibration produced by chaotic environments  

CERN Document Server

We investigate decoherence in quantum systems coupled via dephasing-type interactions to an arbitrary environment with chaotic underlying classical dynamics. The coherences of the reduced state of the central system written in the preferential energy eigenbasis are quantum Loschmidt echoes, which in the strong coupling regime are characterized at long times scales by fluctuations around a constant mean value. We show that due to the chaotic dynamics of the environment, the mean value and the width of the Loschmidt echo fluctuations are inversely proportional to the quantity we define as the effective Hilbert space dimension of the environment, which in general is smaller than the dimension of the entire available Hilbert space. Nevertheless, in the semiclassical regime this effective Hilbert space dimension is in general large, in which case even a chaotic environment with few degrees of freedom produces decoherence without revivals. Moreover ...

2011-01-01

90

Ultrasonic Phased Array Implementation of the Inside Diameter Creeping Wave Sizing Method  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a technique for implementing the ultrasonic inside diameter (ID) creeping wave technique for detection and sizing ID connected defects using a phased array ultrasonic system. The technique uses multiple focal laws to produce the examination modes. The first focal law is designed to create a shear wave nominally at the critical angle for mode conversion to a longitudinal wave at the ID of a part, thus creating a creeping wave. This focal law is focused at the ID to improve sensitivity. The rest of the laws are designed to create tandem sound paths that progress up a vertical surface directly above the focal point of the creeping wave generation point. When a defect on the inner surface is detected with the creeping wave, the height of the defect can be measured from the response of a set of tandem laws without readjusting the position of the probe. Results from standard one-inch long notches of varying depths are presented.

2006-05-01

91

Development of a rapid extraction procedure for speciation of arsenic in chicken meat  

Energy Technology Data Exchange (ETDEWEB)

A rapid extraction procedure has been developed for speciation of arsenic in chicken tissue. Water, methanol-water (1:1), and methanol-chloroform (1:1) were tested as extraction media. Individual use of an ultrasonic bath, a microwave oven, or an ultrasonic probe was not sufficient for quantitative recovery of As(III), dimethylarsinate, monomethylarsonate, As(V), and arsenobetaine in spiked samples of chicken tissue. A new extraction procedure using a methanol-water mixture and a microwave oven then an ultrasonic probe enabled extraction of the arsenic species in 7 min with efficiencies ranging from 80 to 100%. HPLC-UV-HG-AFS was used for the determinations. The extraction procedure was 100% efficient when applied to real samples of chicken tissue. AsB (48{+-}5 {mu}g As kg {sup -1}) and one containing-arsenic feed additive, Nitarsone (227{+-}5 {mu}g As kg {sup -1}) were detected. (orig.)

2006-08-15

92

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill inspection and manipulation requirements were developed for the inspection of the 30 welds ...

1994-12-31

93

An investigation of homogeneous and heterogeneous sonochemistry for the destruction of hazardous substances. Progress report, 1996--1997  

Energy Technology Data Exchange (ETDEWEB)

'The primary objective of this research project is to acquire a deeper fundamental knowledge of acoustic cavitation and cavitation chemistry, and in doing so, to ascertain how ultrasonic irradiation can be more effectively applied to environmental problems. Four on-going projects will be described in this progress report, The first project is the destruction of carbofuran in a Near-Field Acoustical Processor (NAP), and the hydrodynamic characterization of the reactor. The second project is a comprehensive study of how ultrasonic frequency influences sonochemical reaction rates; the substrate it, the preliminary portion of this study has been hydrogen peroxide formation. The third project in progress is destruction of four polychlorinated biphenyls at 20 kHz. Work so far has been at 20 kHz, but the most significant portion of this project will involve a multi-frequency (ultrasonic frequency) study. Finally, the ...

1997-01-01

97

Device for marking and searching for information on a magnetic carrier  

Science.gov (United States)

A device for marking and searching for information on a magnetic carrier is described. In order to increase the noise immunity and reliability of the data recording and reading paths, the recording head is included between the amplifier of the clock pulses for the master oscillator and through the amplifier of the code pulses for the logical element unit. The reproduction head is connected through the code pulse shaper-amplifier with a switch which is connected with the display unit, and through another analogous clock pulse amplifier with a multivibrator.

1984-03-01

100

Free-electron-laser-induced shock-wave control and mechanistic analysis using pulse control  

International Nuclear Information System (INIS)

The wavelength of the free electron laser (FEL) in Osaka University can be continuously varied in the range of 5.0-20.0 #mu#m. The FEL has a double-pulse structure, consisting of a train of macropulses of pulse duration 12 #mu#s. Each macropulse contains a train of 330 micropulses of pulse duration 5 ps. The tunability and picosecond pulses afford new medical and biological applications. However, a macropulse of long pulse duration leads to undesirable secondary effects. Precise control of the macropulse duration is essential for the high-precision applications of the FEL. An FEL pulse control system using acousto-optic modulators has been developed to investigate mechanical (shock-wave) effects of the FEL on living tissues. With this system, we have controlled photoinduced shock waves and determine the mechanism of interaction during FEL-induced tissue ...

2008-11-01

101

Quantitative non-destructive evaluation of high-temperature superconducting materials  

Energy Technology Data Exchange (ETDEWEB)

Even though the currently intensive research efforts on high- temperature superconducting materials have not yet converged on a well specified practical material, the indications are that such a material may be quite brittle, anisotropic, and may contain many flaws such as microcracks and voids at grain boundaries. Consequently, practical applications of high temperature superconducting materials will require a very careful strength analysis based on fracture mechanics considerations. Because of the high sensitivity of the strength of such materials to the presence of defects, methods of quantitative non-destructive evaluation may be expected to play an important role in strength determinations. This proposal is concerned with the use of ultrasonic methods to detect and characterize isolated cracks, clusters of microcracks and microcracks distributed throughout the material. Particular attention has been, and will continue to be devoted to relating ...

1991-06-14

102

New NDT developments for the control of components in the FA3 EPR nuclear reactor at Flamanville; Nouveau developpement END pour le controle de composants de la tranche EPR de Flamanville (FA3)  

Energy Technology Data Exchange (ETDEWEB)

New Non Destructive Testing techniques are currently being developed for the inspection of two groups of components in the FA3 EPR nuclear reactor at Flamanville. The first group of components to be controlled is constituted by the welds of the (89) rod cluster control assemblies' containment; two control types are to be used: an ultrasonic technique (UT) evaluation from the outside of the flange-casing weld, and an ET control from the inside of the three other welds. The second group of components is formed by the 44 welded joints of the primary circuit, which will be inspected through ultrasonic testing. Details of the components, control devices and sensors are given and some test results are presented

2009-07-01

103

Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction  

International Nuclear Information System (INIS)

An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.

2005-04-09

104

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory capacities to permit them to cope with in ...

1992-12-31

105

Extraction of biologic particles by pumping effect in a p-shaped ultrasonic actuator  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a new method of extracting biologic particles from a mixture of particles. The method is based on the pumping effect in a p-shaped ultrasonic actuator, which has a gap between its two vibrating metal plates. An adhesive tape is placed at a proper position in the gap. Due to the pumping effect which is induced by the sound field in the gap, the particles with smaller mass and radius in the mixture can be pumped up to reach the adhesive tape; while the ones with larger mass cannot. Therefore, the particles with smaller mass and radius can be extracted from the mixture. A theoretical model which can well explain the operation principle and experimental phenomena is developed. By the experimental results and the theoretical analyses based on the model, the validity of the m...

2006-01-01

106

Comparison of interface evolution of ultrasonic aluminum and gold wire wedge bonds during thermal aging  

British Library Electronic Table of Contents (United Kingdom)

Ultrasonic gold and aluminum wire wedge bonding are widely used for electrical and signal interconnections of the integrated circuit chip packages. In this paper, based on the metallurgical theories and thermal aging test methods, the long-term thermal reliabilities of gold and aluminum wire wedge bonding on aluminum and Au/Ni/Cu pads, were investigated, respectively. At 200degreeC, the Au/Al bond interfaces evolved little when the storage time was less than 48h; with the aging time increasing, the interfacial intermetallic compounds (IMC) grew up from the pad (vertical growth); the primary compounds were Au5Al2 near the bond toe and heel, and Au2Al at the periphery. Then, the thickness of IMC was unchanged, and extended horizontally (lateral growth), Au5Al2 transformed into more stable Au...

2007-01-01

107

Automatic phased array ultrasonic testing of pressure vessels; Automatisierte Mehrkanal Ultraschallpruefung von Druckgasbehaeltern  

Energy Technology Data Exchange (ETDEWEB)

Automatic ultrasonic testing is presented as a method for recurrent inspections of pressure gas vessels, from validation to practical testing to customised test applications. National and international regulations and standards are presented along with related implementation problems. [German] Es wird die automatisierte Ultraschallpruefung im Bereich der wiederkehrenden Pruefung von Druckgasbehaeltern, als Alternative zur herkoemmlichen, klassischen Wasserdruckpruefung, vorgestellt. Von der Validierung ueber die praktische Erprobung bis hin zur kundenspezifisch entwickelten Pruefapplikation. Es werden die Anforderungen aus nationalen und internationalen Vorschriften und Normen sowie die damit zusammenhaengenden Umsetzungsprobleme behandelt.

2005-07-01

108

Transesophageal echo to help percutaneous closure of ventricular septal defect post acute myocardial infarction  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.

2011-01-01

109

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR Imaging of the joints. (orig.) [Deutsch] ...

1993-12-31

110

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM ...

1998-11-01

111

Theoretical study on device efficiency of pulsed liquid jet pump  

International Nuclear Information System (INIS)

The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries

2001-03-01

112

Influence of duration and rate of pulse rise of the applied voltage on ozone concentration in the barrier glow discharge  

International Nuclear Information System (INIS)

The barrier glow discharge between two planar electrodes, covered with dielectric, is studied under high-voltage pulsed power supply. Wide applications of such type of discharges, in particular, for ozone production, stimulated a number of investigations in this direction. In this work we investigated the dependence of ozone concentration on the duration and the rate of pulse rise of the applied voltage. The thyristor converter circuit with the shortening of input pulses on the base of the saturable throttle was used for the realization of this task. The output pulses with amplitude up to 15 kV, repetition frequency of 1 kHz, pulse duration of 0.3 #mu#s (or 7 #mu#s) and the rate of pulse rise of 0.1 #mu#s were generated with this scheme. Measurements of the ozone concentration produced in the air mixture have shown that its value increased by factor two with ...

2005-09-06

113

Design of electron beam accelerators for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks ...

1988-07-01

114

Design of electron beam accelerator for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can ...

1988-01-01

115

Radiations against tumors: a bit old-fashioned?; Rayonnements contre tumeurs: un rien demode?  

Energy Technology Data Exchange (ETDEWEB)

The proton therapy gives an irradiation adapted to the shape and the depth of tumors ( eyes, head and neck) with a millimetric, even sub millimetric precision for the ophthalmological tumors. It is equally an excellent tool for the pediatrics tumors. For numerous treatments in France the proton therapy is associated to the photons treatments (x radiation). however, others physical treatments could modulate the medical offer, such thermal therapy or treatments by ultrasonic waves. (N.C.)

2004-09-01

116

Phonon relaxation and internal friction in heterogeneous systems based on poly(vinyl chloride)  

British Library Electronic Table of Contents (United Kingdom)

Phonon relaxation and internal friction in kaolin-and bentonite-filled PVC composites are studied. By varying the temperature and/or content of the ultrafine mineral filler in the PVC, one can control the contribution from phonon viscosity, damping force, and the effect of viscosity into the energy dissipation of ultrasonic oscillations in the MHz frequency interval. The dynamic character of the measurements makes it possible to differentiate between relaxation phenomena in the composites and to suggest methods for their controlled changes.

2010-01-01

117

Mobile and Marine Robotics  

Science.gov (United States)

University research group with research areas: * Land based and submersible autonomous robots, (UUVs: AUVs and ROVs); * Controllers, electronics, sensor design and fusion, motion control; * Guidance and navigation of underwater vehicles; * AI, neural networks, fuzzy logic, subsumption control, behaviour based control; * Optical fibre and ultrasonic sensors for proximal object detection; * Robot arm control, visual servoing; * Imaging sonar applications; * Simulator development: UUV simulator; imaging sonar simulator; Aircraft/flight simulator.

2007-07-01

118

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

119

Domestic and industrial applications of microwaves; Les micro-ondes dans les applications domestiques et/ou industrielles  

Energy Technology Data Exchange (ETDEWEB)

In addition to their use in high-speed ovens, microwaves are also finding applications in industrial manufacture, quality control and storage - anywhere where the high-frequency transmission or reflection properties of a material can be exploited. Microwaves are also being used in medical applications for the characterization of certain type of tumours. They are also being used in research into ultrasonic cavitation. (authors) 5 refs.

1999-01-01

120

Development of techniques for joining of high-sensitivity solar cells. Final report; Entwicklung von Verbindungstechniken fuer hoch empfindliche Solarzellen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The report investigates a number of joining techniques, i.e. isothermal solidification, ultrasonic welding, thermocompression, and glueing. (HW) [Deutsch] In diesem Vorhaben wurden verschiedene Verbindungstechniken untersucht: Isotherme Erstarrung; Ultraschall-Schweissen; Thermokompression; Leitkleben. (HW)

1992-09-01

121

An ultrasonic goniometer for surface stress measurement  

Science.gov (United States)

An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.

1978-09-01

122

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

123

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

124

Interplay of the chirps and chirped pulse compression in a high-gain seeded free-electron laser  

International Nuclear Information System (INIS)

In a seeded high-gain free-electron laser (FEL), where a coherent laser pulse interacts with an ultrarelativistic electron beam, the seed laser pulse can be frequency chirped, and the electron beam can be energy chirped. Besides these two chirps, the FEL interaction introduces an intrinsic frequency chirp in the FEL even if the above-mentioned two chirps are absent. We examine the interplay of these three chirps. The problem is formulated as an initial value problem and solved via a Green function approach. Besides the chirp evolution, we also give analytical expressions for the pulse duration and bandwidth of the FEL, which remains fully longitudinally coherent in the high-gain exponential growth regime. Because the chirps are normally introduced for a final compression of the FEL pulse, some conceptual issues are discussed. We show that to get a short pulse duration, an energy ...

2007-03-01

125

Finite-duration Seeding Effects in Powerful Backward Raman Amplifiers  

Energy Technology Data Exchange (ETDEWEB)

In the process of backward Raman amplification (BRA), the leading layers of the seed laser pulse can shadow the rear layers, thus weakening the effective seeding power and affecting parameters of output pulses in BRA. We study this effect numerically and also analytically by approximating the pumped pulse by the ''*-pulse'' manifold of self-similar solutions. We determine how the pumped pulse projection moves within the *-pulse manifold, and describe quantitatively the effective seeding power evolution. Our results extend the quantitative theory of BRA to regimes where the effective seeding power varies substantially during the amplification. These results might be of broader interest, since the basic equations, are general equations for resonant 3-wave interactions.

2003-07-14

126

Electron yield enhancement in a laser wakefield accelerator driven by asymmetric laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The effect of asymmetric laser pulses on electron yield from a laser wakefield accelerator has been experimentally studied using > 10{sup 19} cm{sup -3} plasmas and a 10 TW, > 45 fs, Ti:Al{sub 2}O{sub 3} laser. Laser pulse shape was controlled through non-linear chirp with a grating pair compressor. Pulses (76 fs FWHM) with a steep rise and positive chirp were found to significantly enhance the electron yield compared to pulses with a gentle rise and negative chirp. Theory and simulation show that fast rising pulses can generate larger amplitude wakes that seed the growth of the self-modulation instability and that frequency chirp is of minimal importance for the experimental parameters.

2002-08-01

127

Coherently pulsed laser source  

Energy Technology Data Exchange (ETDEWEB)

An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.

1982-06-01

128

IMPROVED NATURAL GAS STORAGE WELL REMEDIATION  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report covers activities ...

2001-12-01

129

System suitable for use in neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating ...

1990-02-07

130

System suitable for use in neutron radiography  

International Nuclear Information System (INIS)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating ...

1988-07-20

131

Pulsed Dye Laser Induced Inflammatory Response and Extracellular Matrix Turnover in Rat Vocal Folds and Vocal Fold Fibroblasts  

UK PubMed Central (United Kingdom)

Background and ObjectivesDisruption of the vocal fold extracellular matrix (ECM) can induce a profound and refractory dysphonia. Pulsed dye laser (PDL) irradiation...Full Text Available

2009-10-01

132

Pulse compression in a free electron laser amplifier  

International Nuclear Information System (INIS)

We have studied both theoretically and experimentally a new scheme of active pulse compression in a free electron laser (FEL) amplifier. The pulse compression scheme presented here is the following. A frequency-chirped pulse is injected into the FEL interaction region. Because of the high gain and narrow bandwidth of the FEL interaction, only the resonant frequency band of the pulse is actively amplified, resulting in a short pulse of high power coherent radiation at the output of the laser. For our experimental parameters (beam voltage #approx =# 150 kV, current #approx =# 5.0 A, wiggler period #approx =# 3.5 cm and gain #approx =# 10 dB), pulses of a few nanoseconds were generated at #approx =# 10 GHz after an interaction length of 2.30 m, in good agreement with theoretical expectations. For the same input pulses (width > 100 ns, ...

133

Nonlinear transmission of two successive ultrashort laser pulses by a thin semiconductor film under two-photon generation of biexcitons. Giant oscillator strength model  

International Nuclear Information System (INIS)

The possibility to compress and to split laser pulses at their nonlinear optical transmission through semiconductor films was investigated

2011-07-07

134

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

135

High efficiency coupling and guiding of intense femtosecond laser pulses in preformed plasma channels in an elongated gas jet  

International Nuclear Information System (INIS)

We report coupling and guiding of pulses of peak power up to 0.3 TW in 1.5 cm long preformed plasma waveguides generated in a high repetition rate argon gas jet. Coupling of up to 52% was measured for 50 mJ, -110 fs pulses injected at times longer than 20 ns, giving guided intensities up to -5x1016 W/cm2. It was found that for short delays between waveguide generation and pulse injection, pulse shortening occurred, with this effect reduced as delay was increased. Injection into the waveguide of two consecutive pulses separated by a few nanoseconds resulted in the reduction of shortening of the second pulse at all delays. Femtosecond time-resolved shadowgrams of the coupling of injected pulses into the waveguide show that there is ?0.5 mm of neutral gas remaining at the waveguide entrance after waveguide generation.

1999-07-12

136

Development of a coal fired pulse combustor for residential space heating. Technical progress report, October--December 1986  

Energy Technology Data Exchange (ETDEWEB)

This progress report presents a detailed description of the background, technology and application, and Statement of Work for the development of a coal-fired pulse combustor for residential space heating.

1986-12-31

137

Acousto-optic multiplexing and demultiplexing  

Energy Technology Data Exchange (ETDEWEB)

A system is claimed for multiplexing or demultiplexing pulsed laser radiation having an acousto-optical device which is electrically controlled to switch a common path of high pulse rate laser radiation between a plurality of spatially distinct paths for relatively lower pulse rate laser radiation at which the pulses are sequenced according to a predetermined time pattern. The acousto-optical element typically includes a Bragg cell which is electrically driven by a set of distinct frequencies, causing deflection of radiation passing therethrough at a predetermined set of angles whereby pulsed radiation on a single path may be distributed onto the plural separate paths or radiation on plural separate paths of time-sequenced pulses of radiation can be combined into a single path of augmented pulse rate. The control of the acousto-optical ...

1980-06-03

138

Using ICCD as a fast optical switch to measure harmonic super-radiation from an optical klystron in a storage ring  

International Nuclear Information System (INIS)

An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate

2001-07-01

139

The Effect of the Temperature to Which the Material is Heated ...  

Science.gov (United States)

... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...

1980-09-01

141

Research on Nanosecond Pulse Corona Discharge Attenuation  

Science.gov (United States)

A line-to-plate reactor was set-up in the experimental study on the application of nanosecond pulsed corona discharge plasma technology in environmental pollution control. Investigation on the attenuation and distortion of the amplitude of the pulse wave front and the discharge image as well as the waveform along the corona wire was conducted. The results show that the wave front decreases sharply during the corona discharge along the corona wire. The higher the amplitude of the applied pulse is, the more the amplitude of the wave front decreased. The wave attenuation responds in a lower corona discharge inversely. To get a higher efficiency of the line-to-plate reactor a sharp attenuation of the corona has to be considered in practical design.

2007-12-01

142

Picosecond timing of terawatt laser pulses with the SLAC 46 GeV electron beam  

International Nuclear Information System (INIS)

We report on the collision of 1.5 ps (FWHM) laser pulses traversing at 17 a short similar 7 ps (FWHM) 46.6 GeV electron bunch. The phase-locked system used to maintain the correct timing of the laser pulses and the appropriate diagnostics are described. The jitter between the laser and electron pulses is determined from the stability of the observed rate of Compton scatters and can be described by a Gaussian distribution with #sigma#_j#approx =#2.2 ps. (orig.).

143

Optical SETI with Air Cerenkov Telescopes  

CERN Document Server

We propose using large Air Cerenkov Telescopes (ACT's) to search for optical, pulsed signals from extra-terrestrial intelligence. Such dishes collect tens of photons from a nanosecond-scale pulse of isotropic equivalent power of tens of solar luminosities at a distance of 100 pc. The field of view for giant ACT's can be on the order of ten square degrees, and they will be able to monitor 10 to 10$^2$ stars simultaneously for nanosecond pulses of about 6th mag or brighter. Using the Earth's diameter as a baseline, orbital motion of the planet could be detected by timing the pulse arrival times.

2001-01-01

144

Operating Manual for Single-Shot Autocorrelator  

Science.gov (United States)

... pulses by a 50/50 beamsplitter and recombined in space and in time inside a wafer of KDP crystal which generates a second harmonic of the ...

1993-01-01

146

Magnetic Tape Pulse Width to Digital Convertor.  

Science.gov (United States)

... This is achieved by the use of a unique logic circuit employing a plurality of flip-flop devices, multivibrators and AND gates. ...

1976-12-07

150

High intensity lasers for gamma-gamma colliders  

International Nuclear Information System (INIS)

Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).

151

Generation of high-energy electrons and ions at propagation of relativistic laser pulses through supercritical plasma  

International Nuclear Information System (INIS)

In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions

2007-12-01

154

Case for applying subnanosecond high-intensity, electrical pulses to biological cells.  

Science.gov (United States)

In this paper, model analysis into the time-dependent transmembrane potential at the outer cell membrane is presented, for applied high-intensity electric pulses having durations in the nanosecond range or smaller. It is argued that the frequency-dependent dielectric response of cell membranes could be used to advantage for stronger bioeffects by employing shorter pulses. Our model calculations predict faster transmembrane voltages and larger electroporation densities for a given external energy with pulse durations in the subnanosecond regime. This temporal regime would be used, for example, in the electrotherapy of mixed cell ensembles having different dielectric response properties. PMID:21937300

2011-10-01

155

Basic Research Leading to Compact, Portable Pulsed Power  

Science.gov (United States)

... 1 ..... 14 High Dielectric Constant Ceramics for Use in Blumlein Transmission Lines ..... 14 ...

2007-03-31

156

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

157

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...

1999-05-01

158

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are ...

2006-02-01

159

MRI with pathogenic correlation of small renal cell carcinoma  

Energy Technology Data Exchange (ETDEWEB)

MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which showed low signal intensity of T2-weighted ...

1999-11-01

160

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

161

Experiment for deep seismic reflections in Hidaka, Hokkaido. Comparison between Vibroseis and explosive data; Hidaka chiiki ni okeru shinbu hanno data no shutoku jikken. Vibroseis to dynamite no hikaku  

Energy Technology Data Exchange (ETDEWEB)

This is a prompt report. These days the importance of acquiring knowledge about the structure from the lower crust down to the upper mantle is often discussed with reference taken to Hyogo-ken Nanbu Earthquake. The Hidaka collision belt where the lower crust is exposed on the surface is a rare phenomenon in the world and has been the subject of seismic survey. As a part of the survey, experiments are conducted by the use of vibrations produced by Vibroseis and dynamite sources. Every one of the shot records (20-second record) from the two types of vibration sources contains a clear echo in the vicinity of 16 seconds supposedly from a level deeper than 40 kilometers, not to mention reflections from shallow levels. Although some studies have to be conducted before the reflecting geological boundary (possibly the upper mantle) of the echo near the 16-second point can be identified, yet this is probably the reflection from the deepest level ever ...

1997-05-27

162

Comparison of contrast-enhanced flash and turbo-flash with conventional spin-echo sequences as a basis for morphologocal MR imaging for planning high-precision radiotherapy of intracranial brain tumors. Comparison of FLASH-, turbo-FLASH and SE-sequences; Morphologische MR-Bildgebung mit T1-gewichteten Sequenzen zur radiotherapeutischen Zielvolumendefinition von intrakraniellen Tumoren. Vergleich von FLASH-, Turbo-FLASH- und SE-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of ...

1997-03-01

163

Time-resolved measurement of a self-amplified free-electron laser  

International Nuclear Information System (INIS)

We report on a time-resolved measurement of self-amplified spontaneous emission free-electron laser (FEL) pulses. We observed that the spikes in such FEL pulses have an intrinsic positive chirp and the energy chirp in the electron bunch mapped directly into the FEL output. The measurement also provides rich information on the statistics of the FEL pulses.

2003-07-11

164

Shaping pulses using frequency conversion with a modulated picosecond free electron laser  

Energy Technology Data Exchange (ETDEWEB)

Computer simulations and experiments indicate that we can shape the infrared picosecond pulses of the Mark III FEL in amplitude, frequency, and phase. Strongly modulated fundamental and second harmonic pulses have been generated by operating the Mark III FEL in the regime of strong sideband growth. In this paper, we present the results of simulations and experiments for second harmonic generation with fundamental inputs from 2 to 3 {mu}m.

1995-12-31

165

Monolithic stabilized Yb-fiber All-PM laser directly delivering nJ-level femtosecond pulses  

DEFF Research Database (Denmark)

We present a monolithic, self-starting, all-PM, stabilized Yb-fiber laser, pulse-compressed in a hollow-core PM photonic crystal fiber, providing the 370 fs pulses of 4 nJ energy with high mode quality.

2008-01-01

166

MIZAR mz8310  

Science.gov (United States)

The mz8310 device support module provides support for the following record types: event, pulseCounter, pulseDelay, and pulseTrain. No driver support is needed. Up to 4 mz8310 modules are supported. Each 8310 module contains 10 channels, which are identified as signals O,...9. Each channel is individually configurable. Each mz83 10 has two Am9513 Timing Controller chips. Each Am9513 has 5 counters.

1992-07-09

167

Power cables: methods of defects localization; Cables d'energie: methodes de localisation des defauts  

Energy Technology Data Exchange (ETDEWEB)

The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)

2006-08-15

168

The use of short-echo-time {sup 1}H MRS for childhood cerebellar tumours prior to histopathological diagnosis  

Energy Technology Data Exchange (ETDEWEB)

Proton magnetic resonance spectroscopy (MRS) measures concentrations of metabolites in vivo and provides a powerful method for identifying tumours. MRS has not entered routine clinical use partly due to the difficulty of analysing the spectra. To create a straightforward method for interpreting short-echo-time MRS of childhood cerebellar tumours. Single-voxel MRS (1.5-T Siemens Symphony NUM4, TR/TE 1,500/30 ms) was performed at presentation in 30 children with cerebellar tumours. The MRS results were analysed for comparison with histological diagnosis. Peak heights for N-acetyl aspartate (NAA), creatine (Cr), choline (Cho) and myo-inositol (mIns) were determined and receiver operator characteristic curves used to select ratios that best discriminated between the tumour types. The method was implemented by a group of clinicians and scientists, blinded to the results. A total of 27 MRS studies met the quality control criteria. NAA/Cr >4.0 distinguished all but ...

2007-11-15

169

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children ...

2000-07-01

170

MR imaging of regional late brain development  

International Nuclear Information System (INIS)

This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential age-dependent patterns of mean T2 values emerged between the six FSCWM sites. The ...

171

VLF wave stimulation by pulsed electron beams injected from the space shuttle  

International Nuclear Information System (INIS)

Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.

172

Resonantlike phenomenon in short-pulse free-electron-laser oscillators with modulated desynchronism  

International Nuclear Information System (INIS)

Recently a new method of controlling the pulse length of a short-pulse free-electron laser (FEL) has been developed. By modulating the synchronism between the optical and electron pulses in the FEL cavity, it was found that the output power and the micropulse length of the FEL beam oscillates at the modulation frequency. In this paper, we study theoretically the behavior of the micropulse length, both in the high loss (steady state) regime and the low loss (limit cycle) regime, when a modulated desynchronism is applied. In order to do this, we analyze the dynamics of a short-pulse FEL oscillator. The modulation frequency value plays an important role in the dynamics. We find that there is a resonantlike phenomenon between the externally applied desynchronism modulation and the limit cycle oscillation without modulation of a free-electron laser.

2002-01-01

173

Optimal dynamic detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

The detection of explosives is a notoriously difficult problem, especially at stand-off distances, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring optimal dynamic detection to exploit the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity of explosives signatures while reducing the influence of noise and the signals from background interferents in the field (increase selectivity). These goals are being addressed by operating in an optimal nonlinear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked control and probe ...

2009-01-01

174

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as cryo-permanent magnets in potential applications ...

2005-02-01

175

Demonstrating coherent control in 85Rb2 using ultrafast laser pulses: a theoretical outline of two experiments  

CERN Document Server

Calculations relating to two experiments that demonstrate coherent control of preformed rubidium-85 molecules in a magneto-optical trap using ultrafast laser pulses are presented. In the first experiment, it is shown that pre-associated molecules in an incoherent mixture of states can be made to oscillate coherently using a single ultrafast pulse. A novel mechanism that can transfer molecular population to more deeply bound vibrational levels is used in the second. Optimal parameters of the control pulse are presented for the application of the mechanism to molecules in a magneto-optical trap. The calculations make use of an experimental determination of the initial state of molecules photoassociated by the trapping lasers in the magneto-optical trap and use shaped pulses consistent with a standard ultrafast laser system.

2009-01-01

176

A numerical study of ultra-short-pulse reflectometry  

Energy Technology Data Exchange (ETDEWEB)

Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude ...

1994-05-01

177

Nonlinear pulse evolution in seeded free-electron laser amplifiers and in free-electron laser cascades  

International Nuclear Information System (INIS)

The advances in laser technology have made available very short and intense laser pulses which can be used to seed a high-gain single-pass free-electron laser (FEL) amplifier. With these seed pulses, a regime of the FEL interaction where the radiation evolution is simultaneously dominated by nonlinear effects (saturation) and time-dependent effects (slippage) can be explored. This regime is characterized by the propagation of a solitary wavelike pulse where the power of the optical wave grows quadratically with time, its pulse length decreases and the spectral bandwidth increases. We analyze the interplay between the field and particle dynamics of this propagation regime which was studied before and termed super-radiance. Furthermore we analyze the properties of the strong higher-order harmonic emission from this wave and its behavior when propagating in a cascade FEL. The super-radiant ...

2005-08-15

178

Time-of-Flight Measurements from Eddy Current Tests  

Science.gov (United States)

Data fusion techniques are based on the premise that two or more carefully designed NDE tests are potentially capable of offering additional information concerning the test object relative to what can be garnered from a single test. However, information from a heterogeneous set of transducers cannot be fused unless the data is mapped onto a common `format'. The eddy current method cannot, for example, provide time-of-flight information that can be combined from estimates derived from ultrasonic tests. This paper presents a simple solution to address the problem by employing the so-called Q-transform to relate diffusive fields, such as those generated by eddy current probes, and propagating wave fields generated by ultrasonic NDT sensors. The paper illustrates how the distance between a defect and a source can be extracted from eddy current data generated using carefully selected excitation signals. Numerical results and comparisons with ...

2003-03-01

179

Synthesis and characterization of Al{sub 2}O{sub 3}/ZrO{sub 2}, Al{sub 2}O{sub 3}/TiO{sub 2} and Al{sub 2}O{sub 3}/ZrO{sub 2}/TiO{sub 2} ceramic composite particles prepared by ultrasonic spray pyrolysis  

Energy Technology Data Exchange (ETDEWEB)

Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.

2002-08-01

180

Synthesis and characterization of Al_2O_3/ZrO_2, Al_2O_3/TiO_2 and Al_2O_3/ZrO_2/TiO_2 ceramic composite particles prepared by ultrasonic spray pyrolysis  

International Nuclear Information System (INIS)

Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.

2002-08-01

181

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet customers' ...

1999-12-01

182

Porous tooling process for manufacture of graphite/polyimide composites. Final report  

Energy Technology Data Exchange (ETDEWEB)

A porous tooling system was selected for the processing of Graphite/PMR-15 Polyimide laminates in thickness up to 3.2 mm. (0.125 inch). This tool system must have a reasonable strength, permeability dimensional stability, and thermal conductivity to accomplish curing at 600 F and 200 psi and 200 psi autoclave temperature and pressure. A permeability measuring apparatus was constructed and permeability vs. casting water level determined to produce tools at three different permeability levels. On these tools, laminates of 5, 11, and 22 plies (.027, .060, and 0.121 inch) were produced and evaluated by ultrasonic, mechanical, and thermal tests to determine the effect of the tool permeability on the cured laminates. All tools produced acceptable laminates at 5 and 11 plies but only the highest permeability produced acceptable clear ultrasonic C-Scans. Recommendations are made for future investigations of design geometry, and strengthening techniques ...

1981-01-01

183

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...

1995-08-01

184

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

185

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the detectability of these probes. (author).

1991-08-01

186

Advanced direct liquefaction concepts for PETC generic units. Quarterly report, October 1991--December 1991  

Science.gov (United States)

A laser pyrolysis technique has been used to produce ultrafine particles of iron carbide with diameters ranging from 2 to 20 nm. Catalysis using iron carbide was investigated in the liquefaction of Wyodak subbituminous coal; yields were determined. A study was carried out to examine the possibility of using an ultrasonic extraction technique as a rapid method of product work-up of samples following pretreatment or liquefaction experiments. A similar study had shown that extraction of coal-derived products by an ultrasonic method was rapid and gave yields and product distributions comparable to those obtained by Soxhlet extraction. On another project, three different types of supported catalysts were used to test activity for the combined water-gas shift hydrogenation of a synthetic donor solvent. The three catalysts tested were: (1) Alumina supported NiMo catalyst-Shell 324m; (2) Bulk hydrous TiO NiMo catalyst; (3) Thin film hydrous TiO ...

1991-12-31

187

Nondestructive Technique Survey for Assessing Integrity of Composite Firing Vessel  

Energy Technology Data Exchange (ETDEWEB)

The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.

2000-08-01

188

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

189

Decontamination of Johnston Island Coral: a preliminary study  

International Nuclear Information System (INIS)

A preliminary investigation was completed on the characterization and decontamination of coral samples from Johnston Island. These samples were found to contain individual particles (2 to 0.25 mm) of contaminated coral as well as a piece of contaminated magnetic metal. They ranged in activity from about 70 to 811 nCi Am-241. The decontamination methods investigated were froth flotation, ferrite treatment, attrition scrubbing, ultrasonic treatment and dry sieving. Dry sieving, the more effective technique, separated about 42 wt % of the coral into a decontaminated fraction. This fraction (>4 mm) contained about 0.5% of the total activity. 7 refs., 3 tabs.

190

Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983  

Science.gov (United States)

During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.

1984-10-01

191

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

192

Simulating quantum search algorithm using vibronic states of I_2 manipulated by optimally designed gate pulses  

International Nuclear Information System (INIS)

In this paper, molecular quantum computation is numerically studied with the quantum search algorithm (Grover's algorithm) by means of optimal control simulation. Qubits are implemented in the vibronic states of I_2, while gate operations are realized by optimally designed laser pulses. The methodological aspects of the simulation are discussed in detail. We show that the algorithm for solving a gate pulse-design problem has the same mathematical form as a state-to-state control problem in the density matrix formalism, which provides monotonically convergent algorithms as an alternative to the Krotov method. The sequential irradiation of separately designed gate pulses leads to the population distribution predicted by Grover's algorithm. The computational accuracy is reduced by the imperfect quality of the pulse design and by the electronic decoherence processes that are modeled by the non-Markovian ...

2010-04-01

193

Positive pulsed corona discharge process for simultaneous removal of SO{sub 2} and NO{sub x} from iron-ore sintering flue gas  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak ...

1999-08-01

194

Low-level microwave irradiations affect central cholinergic activity in the rat  

Energy Technology Data Exchange (ETDEWEB)

Sodium-dependent high-affinity choline uptake was measured in various regions of the brains of rats irradiated for 45 min with either pulsed or continuous-wave low-level microwaves (2,450 MHz; power density, 1 mW/cm2; average whole-body specific absorption rate, 0.6 W/kg). Pulsed microwave irradiation (2-microseconds pulses, 500 pulses/s) decreased choline uptake in the hippocampus and frontal cortex but had no significant effect on the hypothalamus, striatum, and inferior colliculus. Pretreatment with a narcotic antagonist (naloxone or naltrexone; 1 mg/kg i.p.) blocked the effect of pulsed microwaves on hippocampal choline uptake but did not significantly alter the effect on the frontal cortex. Irradiation with continuous-wave microwaves did not significantly affect choline uptake in the hippocampus, striatum, and hypothalamus but decreased the uptake in the frontal cortex. The ...

1987-01-01

195

High extraction efficiency observed at the JAERI free-electron laser  

International Nuclear Information System (INIS)

A high power Free-Electron Laser (FEL) has lased at a wavelength of 22 #mu#m at the Japan Atomic Energy Research Institute (JAERI). The maximum power on a macro-pulse average is 1.7 kW, and it corresponds to an FEL energy of 160 #mu#J/micro-pulse. Extraction efficiency from the electron beam to the FEL radiation was measured to be 5.3% by an energy analyzer, when the maximum FEL power was coupled out. The rms wavelength spread was measured to be 4.6% at the same time. The extraction efficiency, in general, has a maximum value near the zero detuning length of an optical cavity, where (in contrast) the single-pass gain becomes smallest. A high peak current and a long macro-pulse duration are therefore indispensable for realizing high efficiency. The electron beam energy is 16.5 MeV, and the average current is 5.3 mA at a micro-pulse repetition rate of 10.4 MHz. The macro-pulse ...

2001-12-21

196

Development and testing of commercial-scale, coal-fired combustion systems, Phase 3. Technical progress report, October 1990--December 1990  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy`s Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also ...

1990-12-31

197

Development and testing of commercial-scale, coal-fired combustion systems, Phase 3  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and ...

1990-01-01

198

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

199

Self-seeded injection-locked FEL amplifier  

Energy Technology Data Exchange (ETDEWEB)

A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.

1998-12-01

200

Relaxation oscillation of amplified spontaneous radiation pulse emitted from a single-mirror Cu/CuBr laser  

Energy Technology Data Exchange (ETDEWEB)

The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.

1985-10-01

201

Measurement of low-energy laser pulse duration in femtosecond range  

International Nuclear Information System (INIS)

Measurements of low-energy (#approx#10"- "1"0 J) femtosecond laser pulse durations have been carried out on the basis of second-order autocorrelation function analysis. The scheme of non collinear second harmonic generation realized in KDP crystal has been used for increasing of the measurement contrast and accuracy. Proposed scheme can be used for measurements in wide enough ranges of laser pulse durations (from tens femto seconds to hundreds picoseconds) and energies. (authors)

202

Effect of 9. 6-GHz pulsed microwaves on the orb web spinning ability of the cross spider (Araneus diadematus)  

Energy Technology Data Exchange (ETDEWEB)

Eight cross spiders (Araneus diadematus) were exposed overnight (16 h) during web-building activity to pulsed 9.6-GHz microwaves at average power densities of 10, 1, and 0.1 mW/sq. cm. (estimated SARs 40, 4, and 0.4 mW/g). Under these conditions, 9.6-GHz pulsed microwaves did not affect the web-spinning ability of the cross spider.

1986-01-01

203

Coating of metallic membranes by pulsed laser deposition; Beschichtung von metallischen Membranen mittels Pulsed Laser Deposition  

Energy Technology Data Exchange (ETDEWEB)

There is increasing demand to functionalize meso- and nano-porous materials by coating and make the porous substrate biocompatible or environment friendly. However, coating on a meso-porous substrate poses great challenges, especially if the pore aspect ratio is high. In the current work the pulsed laser deposition (PLD) method is used for coating Ni{sub 3}Al-based meso-porous membranes with diamond-like carbon (DLC) layers of high thickness homogeneity and adhesion. (orig.)

2008-08-15

204

All Optical Switch of Vacuum Rabi Oscillations: The Ultrafast Quantum Eraser  

CERN Document Server

We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.

2010-01-01

205

Technique for the removal of electrons from an extracted, pulsed, H{sup {minus}} ion beam  

Energy Technology Data Exchange (ETDEWEB)

A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}

1996-10-01

206

SHORT PULSE LASERS  

Science.gov (United States)

... main in this state only for 10-8 secs., after which they decay to the meta- stable state (fluorescent level) because of spontaneous radiation or other ...

1962-10-01

207

Pulsed Plasma Preparation for LWIR Materials  

Science.gov (United States)

... at compositions below -AlP 4 the films were still unstable, hydrolysing in room air, and the long term stability of higher aluminium phosphides is in ...

1990-06-18

208

Properties of hot-pressed Fe sintered materials by plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N{sub 2} : H{sub 2}) and pulsed ratio (pulse on/off time ratio)

2002-05-01

209

Properties of hot-pressed Fe sintered materials by plasma nitriding  

International Nuclear Information System (INIS)

This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N_2 : H_2) and pulsed ratio (pulse on/off time ratio).

2002-05-01

211

Picosecond pulse-conductivity technique applied to study excess-electron reactions in hydrocarbon mixtures  

Energy Technology Data Exchange (ETDEWEB)

To measure electron reactions on a picosecond timescale the investigators developed a picosecond pulse-conductivity technique, which makes use of the electron fine-structure pulses of our LINAC (pulse width 25 vs FWHM) to produce excess electrons and now detects changes in sample conductance under optimum conditions with an instrumental response of 18 ps. This resolution is in agreement with a theoretical estimate. This technique has been successfully applied to study excess electron reactions in solvents covering a mobility range from 0.24 to 100 cm/sup 2/V/sup -1/s/sup -1/; extension to lower mobility liquids seem possible.

1983-01-01

212

Parametric study of pulsed thermal bumps in supersonic boundary layer  

British Library Electronic Table of Contents (United Kingdom)

A three-dimensional numerical study is performed to explore the effect of pulsed spanwise-periodic surface thermal perturbation (also denoted as thermal bump) in a Mach 1.5 flat plate laminar boundary layer. A high-resolution upwind-biased Roe method is used with the compressive Van Leer harmonic limiter on a suitably refined mesh. The dependence of flow stability characteristics on the variation of thermal bump geometry (shape and dimension) and pulsing properties (disturbance amplitude and frequency) is assessed. It is shown that the finite-span thermal bumps generate streamwise vortices. When the thermal bump is pulsed, vortex shedding is observed, and the streamwise vorticity grows with the downstream distance. Analysis of the integrated disturbance energy indicates that the streamwise...

2011-01-01

213

Microwave excitation of a CO/sub 2/ laser. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

A flowing carbon dioxide laser was operated at low pressures up to 4 torr. Excitation of the laser was provided using various combinations of direct current (DC), pulsed microwave, and continuous wave (CW) microwave excitation. The microwaves were in the 2.45 GHz band and were coupled into the gas using a slow-wave interdigital transmission line. Laser output of 25 milliwatts (mw) was achieved using a DC discharge only. A combination of a DC discharge and pulsed microwaves doubled the output and resulted in some modulation. Changing the laser gas mixture and pulsed microwave field characteristics allowed some flexibility in the modulation. Lasing was not achieved with excitation from the CW microwaves alone due to the formation of localized discharges. Using pulsed microwaves to sustain the discharge and CW microwaves to pump the laser, a quasi-CW output of 55 mw was achieved.

1983-12-01

214

Liquid nitrogen temperature operation of a switching power converter  

Science.gov (United States)

The performance of a 42/28 V, 175 W, 50 kHz pulse-width modulated buck dc/dc switching power

1995-01-01

215

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.

216

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

217

High-power rf-pulsed modulators for the Los Alamos free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

In the rf-driven free-electron laser (FEL) at the Los Alamos National Laboratory, there are two pulsed-power rf modulators as sources for two tandem, side-coupled 20-MeV linear accelerators. The rf power used to control the cavity fields is supplied by two 5.5-MW modulating anode klystrons operating at a center frequency of 1300.2 MHz. The modulation of the 125 kV klystron is achieved by using a triode switch tube that provides a pulse width up to 300 ..mu..s and a pulse repetition rate up to 10 Hz. This paper describes the present configuration of these two duplicate systems and presents plans for meeting the requirements of future rf FEL experiments at Los Alamos. 12 refs., 5 figs.

1987-09-01

218

High intensity lasers for gamma-gamma colliders  

Energy Technology Data Exchange (ETDEWEB)

Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).

1995-02-01

219

Half-period optical pulse generation using a free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Recently there has been growth, in interest in non-equilibrium interaction of half-period long optical pulses with matter. To date the optical pulses have been produced by chopping out a half-period long segment from a longer pulse using a semiconductor switch driven by a femtosecond laser. In this paper we present new methods for producing tunable ultra-short optical pulses as short as half an optical period using a free-electron laser driven by electron bunches with a duration a fraction of an optical period. Two different methods relying on the production of coherent spontaneous emission will be described. In the first method we show that when a train of ultra-short optical pulses as short as one half period. We present calculations which show that the small signal gain is unimportant in the early stages of radiation build up in the cavity when the startup process is dominated by ...

1995-12-31

220

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

221

Electrically triggered all-or-none Ca(2)+-liberation during action potential in the giant alga Chara.  

Science.gov (United States)

Electrically triggered action potentials in the giant alga Chara corallina are associated with a transient rise in the concentration of free Ca(2)+ in the cytoplasm (Ca(2)+(cyt)). The present measurements of Ca(2)+(cyt) during membrane excitation show that stimulating pulses of low magnitude (subthreshold pulse) had no perceivable effect on Ca(2)+(cyt). When the strength of a pulse exceeded a narrow threshold (suprathreshold pulse) it evoked the full extent of the Ca(2)+(cyt) elevation. This suggests an all-or-none mechanism for Ca(2)+ mobilization. A transient calcium rise could also be induced by one subthreshold pulse if it was after another subthreshold pulse of the same kind after a suitable interval, i.e., not closer than a few 100 ms and not longer than a few seconds. This dependency of Ca(2)+ mobilization on single and double pulses ...

2001-07-01

222

Electrically Triggered All-or-None Ca2+-Liberation during Action Potential in the Giant Alga Chara  

Science.gov (United States)

Electrically triggered action potentials in the giant alga Chara corallina are associated with a transient rise in the concentration of free Ca2+ in the cytoplasm (Ca2+cyt). The present measurements of Ca2+cyt during membrane excitation show that stimulating pulses of low magnitude (subthreshold pulse) had no perceivable effect on Ca2+cyt. When the strength of a pulse exceeded a narrow threshold (suprathreshold pulse) it evoked the full extent of the Ca2+cyt elevation. This suggests an all-or-none mechanism for Ca2+ mobilization. A transient calcium rise could also be induced by one subthreshold pulse if it was after another subthreshold pulse of the same kind after a suitable interval, i.e., not closer than a few 100 ms and not longer than a few seconds. This dependency of Ca2+ mobilization on single and double pulses can be simulated by a ...

2001-01-01

223

Effect of an Active Abdominal Pulse Generator on Defibrillation Thresholds with a Dual-Coil, Transvenous ICD Lead System  

British Library Electronic Table of Contents (United Kingdom)

Effect of Abdominal Active Can on DFTs. Introduction: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. Methods and Results: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ...

2006-01-01

224

Direct Detection Optical Intersatelllte Link at 220 Mbps Using ...  

Science.gov (United States)

on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...

225

Development of mini-LIA and primary experiments  

International Nuclear Information System (INIS)

Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

2009-09-01

226

Development of a Transpondersonde for the Super-LOKI ...  

Science.gov (United States)

... The three meteorological rocket systems, in order of ... IC3 and IC4 divides the incoming clock pulses f ... at the junction of the temperature sensor and R ...

1972-02-02

227

Development of KSTAR heating and current drive systems for long pulse operation  

Energy Technology Data Exchange (ETDEWEB)

The heating and current drive systems are being developed to support long pulse, high {beta}, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.

2003-07-01

228

Development of KSTAR heating and current drive systems for long pulse operation  

International Nuclear Information System (INIS)

The heating and current drive systems are being developed to support long pulse, high #beta#, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.

2003-05-29

229

Computer Controlled MHD Power Consolidation and Pulse ...  

Science.gov (United States)

... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...

1990-08-01

230

Afferent mechanisms of microwave-induced biological effects. Annual report, 1 June 1985-31 May 1986  

Energy Technology Data Exchange (ETDEWEB)

Effects of 2450-MHz circularly polarized microwave irradiation on central nervous system functions were studied. Pulsed (microsecond, 500 pps) microwaves decreased high-affinity sodium-dependent choline uptake in the hippocampus and frontal cortex of the rat. The effect on hippocampal choline uptake was blocked by pretreatment with narcotic antagonists. Continuous-wave microwaves of the same power density decreased choline uptake in the frontal cortex only. Furthermore, it was found that the effects of pulsed microwaves on central cholinergic activity are classically conditionable to cues in the exposure environment. The hypothesis that some of the neurological effects of pulsed microwave irradiation are caused by its effect on the auditory system was investigated. Effects of pink noise and pulsed microwaves were compared.

1986-07-01

231

A chirped-pulse regenerative-amplifier FEL for the gamma-gamma collider  

International Nuclear Information System (INIS)

During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-#mu#m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.

1995-05-01

232

A chirped-pulse regenerative-amplifier FEL for the gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-{mu}m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.

1995-05-01

233

A Multichannel Personal Telemetry System Using Pulse ...  

Science.gov (United States)

... Multivibrators were used in the first model, which is called the "MV Model." Mwe second model, "1ST Model," has a saw-toothed voltage. ...

1961-07-01

234

Scoring of brain maturation in developmentally handicapped children with high-field MR imaging  

International Nuclear Information System (INIS)

A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.

235

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T{sub 2}-weighted utrafast turbo-spin-echo sequence (UTSE); MRT versus CT in der Diagnostik von Pneumonien. Evaluation einer T{sub 2}-gewichteten ultraschnellen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary ...

1999-05-01

236

MRI of liposarcomas. Observations on 28 liposarcomas; Magnetresonanztomographie der Liposarkome. Beobachtungen an 28 Liposarkomen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub 1}-weighted images. Only scattered fatty ...

1996-08-01

237

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil; Lymphknotenstaging beim Zervixkarzinom: Ergebnisse der hochaufloesenden Magnetresonanztomographie (MRT) mit einer Phased-Array-Koerperspule  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was ...

1997-03-01

238

Flow mapping for assessment of native and repaired valves  

International Nuclear Information System (INIS)

Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.

239

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

240

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

241

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

242

Second harmonic generation of copper-vapor pulsed laser radiation  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of second harmonic generation in a copper-vapor pulsed laser with an ADP crystal is presented. The ratio of the conversion into the second harmonic is found to depend on the average power of the exciting radiation. The maximum conversion ratio was 8.5%. Thermal self-defocusing is the main obstacle to obtaining high average powers at the double frequency.

1980-08-01

243

Searches for Fast Radio Transients  

CERN Document Server

We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.

2003-01-01

244

Saturation of hot CO/sub 2/ by short 10. 6. mu. m laser pulses  

Energy Technology Data Exchange (ETDEWEB)

Saturation of the absorption of hot CO/sub 2/ by 1.6 ns P(18) and P(20) laser pulses at 10.6 ..mu..m has been measured. Coherent propagation calculations with no fitting parameters are in good agreement with the data and are consistent with a substantial hot-band contribution to the P(20) saturation.

1981-07-01

245

Pulsed plasma processing of effluent pollutants and toxic chemicals  

International Nuclear Information System (INIS)

The author is exploring the efficiency of pulsed plasma processing in the removal of nitrogen dioxide, nitrogen oxide, and other pollutants. This process uses an electrical discharge to create chemical radicals from air molecules. These radicals can react with pollutants and form harmless compounds. Additives such as hydrocarbons are also used to improve the efficiency of the removal. The efficient removal of nitrogen dioxide has required the presence of dilute aqueous solution of ammonia.

1994-05-01

246

Modulation instability of linearly polarized laser pulse in relativistic plasma  

International Nuclear Information System (INIS)

Based on the nonlinear dispersion relation of electromagnetic wave in relativistic plasma, the nonlinear controlling equation for linearly polarized mode is obtained using Karpman's method. The modulation instability of intense laser pulse propagating through relativistic plasma is analyzed and the modulation instability growth rate as a function of perturbation wave number for laser beam propagating through relativistic plasma is given. (authors)

2008-10-01

247

Methodology to assess the effects of magnetohydrodynamic electromagnetic pulse (MHD-EMP) on power systems  

International Nuclear Information System (INIS)

This paper summarizes a method to evaluate the possible effects of magnetohydrodynamic-electromagnetic pulse (MHD-EMP) on power systems. This method is based on the approach adapted to study the impact of geomagnetic storms on power systems. The paper highlights the similarities and differences between the two phenomena. Also presented are areas of concern which are anticipated from MHD-EMP on the overall system operation. 12 refs., 1 fig.

1986-01-01

248

Method of defining features on materials with a femtosecond laser  

Energy Technology Data Exchange (ETDEWEB)

The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.

2006-05-23

249

Mechanisms of the pulse rise-time variations in X-ray proportional counters  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a description of the physical processes governing the variations of the pulse rise-time which occur during the operation of the proportional counter and are due to varying either the count rate or the applied voltage. On the basis of the rise-time concept the differences in the count rate effect observed in various types of proportional counters are discussed.

1981-01-01

250

Long pulse extraction of deuterium negative ion beams from the Kamaboko ion source  

Energy Technology Data Exchange (ETDEWEB)

Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)

1998-07-01

251

Integrated experimental test program on waterhammer pressure pulses and associated structural responses within a feedwater sparger  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The ...

1997-12-31

252

High-brightness photoemitter development for electron accelerator injectors  

Energy Technology Data Exchange (ETDEWEB)

Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.

1985-01-01

253

Fluctuations of the energy of Stokes pulses of resonance coherent SRS  

International Nuclear Information System (INIS)

An analytic solution is obtained for the equations of resonance coherent SRS by neglecting the population of the final level of the Raman transition for the systems with the active-medium length that is smaller than the wavelength of the incident light. For the extended systems, a numerical solution is obtained. The energy distribution of the Stokes pulses is found. The large-scale (about 100%) fluctuations of the Stokes radiation energy were observed in the case of unsaturated amplified spontaneous emission. (nonlinear optical phenomena)

2000-11-30

254

Efficiency of selective IR multiphoton dissociation of molecules in a pulsed gas-dynamic flow interacting with a solid surface  

International Nuclear Information System (INIS)

Isotopically selective IR multiphoton dissociation of molecules (SF_6, CF_3I) in a pulsed gas-dynamic flow interacting with a solid surface was studied for the first time. A noticeable (severalfold) increase in the yield of products (compared to excitation of molecules in an unperturbed flow) without a substantial decrease in the selectivity of the process was observed. Possible reasons for the effect are discussed. (laser applications and other topics in quantum electronics)

2000-08-31

255

Development of a pump-probe facility combining a far-infrared source with laser-like characteristics and a VUV free electron laser  

International Nuclear Information System (INIS)

The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the spent electron beam ...

2001-12-21

256

DC CHARACTERIZATION OF HIGH GRADIENT MULTILAYER INSULATORS  

Energy Technology Data Exchange (ETDEWEB)

We have developed a novel insulator concept that involves the use of alternating layers of conductors and insulators with periods less than 1 mm. We have demonstrated that these structures perform 2 to 5 times better than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present new testing results showing exceptional behavior at DC, with gradients in excess of 110kV/cm in vacuum.

2005-05-26

257

Application of neural networks to pulse-shape analysis of Bragg curves  

Energy Technology Data Exchange (ETDEWEB)

A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.

2006-01-15

258

Adiabatic quantum computing with phase modulated laser pulses  

Energy Technology Data Exchange (ETDEWEB)

Implementation of quantum logical gates for multilevel systems is demonstrated through decoherence control under the quantum adiabatic method using simple phase modulated laser pulses. We make use of selective population inversion and Hamiltonian evolution with time to achieve such goals robustly instead of the standard unitary transformation language. (letter to the editor)

2005-09-23

259

3-D numerical simulation of the transient electromagnetic pulse coupling to double cylinder object  

International Nuclear Information System (INIS)

In this paper, finite-difference time-domain method is used to research the transient electromagnetic pulse (EMP) coupling to the cylinder object which is shielded in another shielding cavity with a hole numerically. The different coupling effectiveness of three transient EMP is simulated. The distribution of the electric field in the shielding cavity and the current on the cavity are researched. The shielding effectiveness is evaluated. (authors)

2006-10-21

260

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

261

Surface modification/alloying using intense pulsed electron beam as a tool for improving the corrosion resistance of steels exposed to heavy liquid metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying of steel surface with aluminum (Al) using Microsecond-pulsed Intense Electron Beams (MIEB-Al) was developed and optimized in order to be used for improving the corrosion resistance of the 316, 1.4970 and T91 steels, exposed to liquid Pb and Pb-Bi-eutectic. The procedure consists in two steps: (i) coating the steel surface with Al or an Al-containing alloy layer and (ii) melting the coating layer and the steel surface layer using intense pulsed electron beam. In order to cover the steel surface with an homogeneous and crack-free Al-alloyed layer, the following experimental conditions are required: Al coating thickness range 5-10mm, electron kinetic energy 120keV; pulse duration 30ms; energy density 40-45J/cm2; number of pulses 2-3. Using the mentioned procedure, the corrosion r...

2011-01-01

262

Single-pulse excimer laser nanostructuring of silicon: A heat transfer problem and surface morphology  

Science.gov (United States)

We present computer modeling along with experimental data on the formation of sharp conical tips on silicon-based three-layer structures that consist of a single-crystal Si layer on a 1 {mu}m layer of silica on a bulk Si substrate. The upper Si layers with thicknesses in the range of 0.8-4.1 {mu}m were irradiated by single pulses from a KrF excimer laser focused onto a spot several micrometers in diameter. The computer simulation includes two-dimensional time-dependent heat transfer and phase transformations in Si films that result from the laser irradiation (the Stefan problem). After the laser pulse, the molten material self-cools and resolidifies, forming a sharp conical structure, the height of which can exceed 1 {mu}m depending on the irradiation conditions. We also performed computer simulations for experiments involving single-pulse irradiation of bulk silicon, reported by other groups. We discuss conditions under ...

2008-05-01

263

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to ...

264

Longitudinal and transverse dynamics of a free electron laser based on a storage ring of second and third generation  

International Nuclear Information System (INIS)

This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or ...

265

Characteristics of pulse corona discharge over water surface  

International Nuclear Information System (INIS)

Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO_2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water was waved by corona ...

2008-12-01

266

3D+1 Lorentz type soliton in air  

CERN Document Server

Up to now the long range filaments have been considered as a balance between Kerr focusing and defocusing by plasma generation in the nonlinear focus. However, it is difficult to apply the above explanation of filamentation in far-field zone. There are basically two main characteristics which remain the same at these distances - the super broad spectrum and the width of the core, while the power in a stable filament drops to the critical value for self-focusing. At such power the plasma and higher-order Kerr terms are too small to prevent self-focusing. We suggest here a new mechanism for stable soliton pulse propagation in far-away zone, where the power of the laser pulse is slightly above the critical one, and the pulse comprises super-broad spectra. For such pulses the diffraction is not paraxial and an initially symmetric Gaussian pulse takes parabolic form at several ...

2011-01-01

267

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

268

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

269

Nitrogen doping into titanium dioxide by the sol?gel method using nitric acid  

British Library Electronic Table of Contents (United Kingdom)

N-doped TiO2 has been prepared by use of sol?gel systems containing titanium alkoxide, with nitric acid as the nitrogen source. The time needed for gelation of the systems was drastically reduced by ultrasonic irradiation. The peaks assigned to the nitrate and nitrous ions were observed by FT-IR measurement during the sol?gel reaction. The N-doping was confirmed by the observation of N?O peaks in the XPS spectrum of the sample heated at 400??C. The nitrate ion acted as an oxidizer of the ethanol solvent and titanium species. The TiO2 became doped with nitrogen oxide species as a result of reduction of nitrate ion incorporated into the dried gel samples. These results indicated that the added nitric acid was reduced during the sol?gel transition and heating process, and the resulting NO spe...

2011-01-01

270

Manufacture and first wall joining for an ITER primary wall module prototype: R and D phase with small scale mock-ups  

International Nuclear Information System (INIS)

In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.

2001-10-01

271

Inspection procedure and essential parameters in NDT qualification; Tarkastusohje ja olennaiset muuttujat NDT-paetevoeinnissae  

Energy Technology Data Exchange (ETDEWEB)

The objective of the inspection qualification is to ensure that applied non-destructive methods (NDT) have the required performance. The approach of the qualification process is systematic and carefully documented and therefore some new requirements can be seen concerning the composition of the documentation. There are also new document types, that only application of the inspection qualification requires. The most important of these is the technical justification, that includes the documented evidences concerning the performance of the inspection system. This publication includes two reports: 'Compilation of the inspection procedure' and 'Essential/influential parameters in NDT qualification'. The former of these discusses the issues to be considered in an inspection procedure especially from the point of view of the mechanised ultrasonic testing. The later report explains the parameters formulated to analyse in the technical ...

2000-06-01

272

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI disorders.

2009-05-15

273

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

274

Electrochemical characterization of MnO2 as the cathode material for a high voltage hybrid capacitor  

British Library Electronic Table of Contents (United Kingdom)

Manganese dioxide (MnO2) was prepared using the ultrasonic method. Its electrochemical performance was evaluated as the cathode material for a high voltage hybrid capacitor. And the specific capacitance of the MnO2 electrode reached 240 F.g-1. The new hybrid capacitor was constructed, combining Al/Al2O3 as the anode and MnO2 as the cathode with electrolyte for the aluminum electrolytic capacitor to solve the problem of low working voltage of a supercapacitor unit. The results showed that the hybrid capacitor had a high energy density and the ability of quick charging and discharging according to the electrochemical performance test. The capacitance was 84.4 mF, and the volume and mass energy densities were greatly improved compared to those of the traditional aluminum electrolytic capacito...

2009-01-01

275

Elastic properties, hardness and indentation fracture toughness of #beta#-sialons  

International Nuclear Information System (INIS)

Dense samples of #beta#-sialons (with z from 1 to 4) were pressuressly sintered for different time (15-240 minutes) and at relatively low temperature of 1600 C using single-phase #beta#-sialon powders synthesized by combustion nitridation. The samples were characterized using ultrasonic method for determination of elastic properties (E,G,#mu#). Also, hardness by Knoop and fracture toughness by Vickers indentation microfracture method was estimated. With increasing z number Young's modulus decreases from 293 to 179 GPa. Simultaneously Poisson ratio increases by about 30%. The highest values of hardness and fracture toughness were obtained for sialon with z equal to 1. (orig.).

1993-10-04

276

Dimensional stability, optical and elastic properties of MgAl{sub 2}O{sub 4} spinel irradiated in FFTF to very high exposures  

Energy Technology Data Exchange (ETDEWEB)

Stoichiometric MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA at temperatures between 385 and 750C to fluences ranging from 2.2 to 24.9 {times} 10{sup 22}n cm{sup {minus}2} (E>0.1 MeV) darken significantly, but do not develop any significant loss in weight or change in dimensions. Similar behavior was observed in both single crystal and fully dense polycrystalline specimens. Measurements of elastic constants by an ultrasonic technique show that no measurable changes occur as a result of the irradiation. These and other results confirm the stability of this material for fusion application as an electrical insulator.

1993-10-01

277

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

278

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

279

Chemical and morphological characterization of mesoporous material supported copper oxide nanoparticles for potential application  

British Library Electronic Table of Contents (United Kingdom)

SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...

2011-01-01

280

Behavior of trace refractory minerals in the lithium metaborate fusion-acid dissolution procedure  

Science.gov (United States)

The feasibility of this procedure was investigated using minerals and ore specimens. The substances were ground then fused using LiBO/sub 2/, quenched with 3% HNO/sub 3/ or mixtures of the acid with 2.5% tartaric acid or 30% H/sub 2/O/sub 2/. The quenched melt was usually completely dissolved within 20 min by placing the beakers in an ultrasonic bath. If any residue was detected, appropriate changes were made in the procedure. Once the procedure has been optimized, any remaining black particles were filtered. If these particles disappeared upon subsequent ignition, they were presumed to have been graphite. Most of the refractory minerals investigated should be expected to be converted to soluble form by this process. 1 table.

1983-12-01

281

Automation techniques for fully automated coil transport; Kanzen jido koiru hanso wo jitsugen shita jidoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Kawasaki Steel started the construction of an automatic steel strip coil transportation system in the 1980's. Presently, most of the in-plant transportation of hot-rolled or cold-rolled coils are automated. For establishing the automatic transportation, there were developed various technologies, such as, the optimum handling technology using artificial intelligence, the technology of preventing additional piling of coils on existing coils by using an ultrasonic wave and a laser beam. Through the improvements of these technologies, a full-automated transportation system has been achieved and the system has contributed substantially toward product quality assurance and cost reduction. This paper gives the changes in the automation technology of coil transportation in the automation of No. 3 finishing hot rolling mill, now having the latest automatic system, in Chiba Works. (author)

1999-12-01

282

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

283

MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen; MRT bei Karotisstens: Einfluss von Stenteigenschaften und Geraeteparametern auf die Darstellbarkeit des Karotislumens  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no ...

2005-03-01

284

MR findings in cases of suspected impacted fracture of the femoral neck  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric ...

1997-09-01

285

Hyperoxia-induced acute lung injury using a pig model. Correlation between MR imaging and histologic results  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a pathological score of 15. Furthermore, significant ...

2001-06-01

286

Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation  

International Nuclear Information System (INIS)

To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type ...

2000-12-01

287

Experimental study of lipiodol ultra-fluid. On its signal intensity in MR imaging  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at 1.0 T is probably responsible for the higher intensity at 1.0 T. When MRI is performed after TAE with ...

1988-11-01

288

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...

2000-08-01

289

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic reference deviations ...

2010-11-21

290

Bone marrow MR imaging as predictors of outcome in hemopoietic stem cell transplantation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25{+-}4.14%) compared to unsuccessful transplants (94.54% {+-}2.93%; p=0.01). Red marrow area percentage correlated positively with duration of symptoms(r=0.428, p=0.026) ...

2008-09-15

291

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain structures and to determine the consistency of ...

2007-01-01

292

In-situ examination of turbine components (blade roots, rotor steeple grooves and disk-blade rim attachments) of low-pressure steam turbine, using phased array technology  

Energy Technology Data Exchange (ETDEWEB)

A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data analysis was done in near-real time. ...

2000-07-01

293

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl chloride tube becomes ...

1997-05-27

294

Thermal processing effects on the functional properties and microstructure of lentil, chickpea, and pea flours  

British Library Electronic Table of Contents (United Kingdom)

Pulses are rich in nutrients. The existence of anti-nutritional components and the length of time required for preparation have, however, limited their frequency of use compared to recommended intake levels. Anti-nutritional components in pulses can be largely removed by heat treatment. Additionally pre-treatment of pulses with heat and processing of seeds into flour could further enhance their use by decreasing processing and preparation times. In this study, trypsin inhibitor activity, functional properties, and microstructural characteristics of flours prepared from different varieties of lentil, chickpea, and pea as affected by roasting and boiling were evaluated. Both thermal treatments resulted in significant reduction (p<0.05) in trypsin inhibitor activity ranging from -95.6% to -37...

2011-01-01

295

The effect of pulse field-strength on electric-field stimulated biosorption of uranium by Kluyveromyces-marxianus IMB3  

Energy Technology Data Exchange (ETDEWEB)

Improved biosorption of uranium by Kluyveromyces marxianus IMB3 biomass was achieved by increasing the electric field strength of delivered pulses from 1.25kV/cm to 2.5kV/cm. Although this had little or no effect on the maximum biosorption capacity (q(max)), at low concentrations of uranium the amount bound to the biomass increased from 70 to 140mg uranium/g biomass. Significant increases in the maximum biosorption capacities (119-180 mg uranium/g biomass) were observed when the pulse field strength was increased from 2.5kV/cm to 3.25kV/cm. (Author).

1996-04-01

296

Retrograde amnesia produced by electron beam exposure: casual parameters and duration of memory loss. Final report for November 84  

Energy Technology Data Exchange (ETDEWEB)

The production of retrograde amnesia (RA) upon electron-beam exposure was investigated. RA production was evaluated using a single-trial avoidance task for 10, 1, and 0.1 microsecond pulsed exposures. The dose-response curve obtained at each pulse duration showed significant RA production. The most effective dose range was 0.1-10 rad at a dose rate of 1,000,000 rad/sec. By employing a 10 rad (1,000,000 rad/s) pulse, a memory loss of the events occurring in the previous 4 sec was demonstrated. The conclusion was that the RA effect might be due to sensory system activation which provided a novel stimulus that masked previous stimuli.

1985-01-01

297

Pulsed laser deposition of titanium-carbonitride thin films  

Energy Technology Data Exchange (ETDEWEB)

The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).

1997-05-15

298

Muon physics with the proposed Pulsed Lepton Source at LAMPF  

Energy Technology Data Exchange (ETDEWEB)

The Pulsed Lepton Source (PLS) project opens some exciting possibilities for muon and neutrino physics . The PLS would use the 0.25 4s proton pulses from the upgraded Proton Storage Ring (PSR) at LAMPF to create short, intense bursts of muons and neutrinos. The neutrino beam would be used for a few fundamentally important weak interaction physics experiments. The muon beams would find a wide variety of applications in both fundamental and applied'' muon physics areas. After a brief discussion of the physical layouts of the PSR and the proposed PLS in Sec. 2 and muon area in Sec. 3, we note some of the muon physics experiments and areas that could advantageously be addressed at the PLS in Secs. 4 and 5, and conclude in Sec. 6.

1992-01-01

299

Modeling of a self-excited pulse combustor and stability analysis  

British Library Electronic Table of Contents (United Kingdom)

The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...

2011-01-01

300

Microstructure and tool electrode erosion in EDMed of TiN/Si_3N_4 composites  

International Nuclear Information System (INIS)

Conductive TiN/Si_3N_4 ceramic composites were processed by electrical discharge machining (EDM) and their microstructure and conductivity were investigated. The whole process of tool electrode wear is evaluated by sinker-EDM. The machined surfaces of TiN/Si_3N_4 ceramic composites were examined by scanning electron microscopy (SEM) and profilometry to determine the surface finish. The electrode wear rate of brass is higher than copper electrode for all EDMed tests. The surface texture was found to have greater dependence on pulse energy. It was observed that the sinker-EDM at higher pulse energy caused severe microdamage in the surface. The surface roughness (Ra) values also increase with increasing pulse energy.

2003-12-20

301

High dielectric constant ceramics for ion-electron sources  

Energy Technology Data Exchange (ETDEWEB)

Ferroelectric disks, coated with proper electrodes, can easily produce a dense plasma cloud when excited with a high-voltage pulse. This plasma can be a source of either electrons or ions depending on the sign of the extracting field set in front of the disk. We present the behavior of the disks operating at high frequency as emitters of both electrons and ions in two experimental configurations: (a) without and (b) with two screening grids. These two screening grids are inserted when the plasma must be confined within the cathode region. The system is capable of providing ion pulses of a few hundred milliamperes, whose length can range from a hundred nanoseconds to dozen microseconds. The electron pulses of energetic electrons have typically an amplitude higher than a couple of amperes. Tests at MHz repetition rate were positive as for stable operation.

2002-08-21

302

GRBs Light Curves - Another Clue on the Inner Engine  

CERN Document Server

The nature of the `inner engine' that accelerate and collimate the relativistic flow at the cores of GRBs is the most interesting current puzzle concerning GRBs. Numerical simulations have shown that the internal shocks' light curve reflects the activity of this inner engine. Using a simple analytic toy model we clarify the relations between the observed $ \\gamma $-rays light curve and the inner engine's activity and the dependence of the light curves on the inner engine's parameters. This simple model also explains the observed similarity between the observed distributions of pulses widths and the intervals between pulses and the correlation between the width of a pulse and the length of the preceding interval. Our analysis suggests that the variability in the wind's Lorentz factors arises due to a modulation of the mass injected into a constant energy flow.

2002-01-01

303

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

304

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

305

Field results using measurement-while-drilling directional systems in Long Beach, California  

Energy Technology Data Exchange (ETDEWEB)

One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.

1981-01-01

306

Development of L-band pillbox RF window  

Energy Technology Data Exchange (ETDEWEB)

A pillbox RF output window was developed for the L-band pulsed klystron for the Japanese Hadron Project (JHP) 1-GeV proton linac. The window was designed to withstand a peak RF power of 6 MW, where the pulse width is 600 {mu}sec and the repetition rate is 50 Hz. A high power model was fabricated using an alumina ceramic which has a low loss tangent of 2.5x10{sup -5}. A high power test was successfully performed up to a 113 kW RF average power with a 4 MW peak power, a 565 {mu}sec pulse width and a 50 Hz repetition rate. By extrapolating the data of this high power test, the temperature rise of the ceramic is estimated low enough at the full RF power of 6 MW. Thus this RF window is expected to satisfy the specifications of the L-band Klystron. (author).

1994-12-31

307

Design: voice activated door opener.  

Science.gov (United States)

A voice activated garage door opener was designed for a handicapped person to open a garage door without assistance. This design uses speech recognition of one word. The activating word that was chosen is "up". The frequency spectrum of "up" was captured on a soundboard and is the basis of this design. Filters are used to pick out three frequency bands in this spectrum. The output signals from these filters are then compared to three threshold voltages using voltage comparators. If the output signals from the filters are above the threshold voltages, the comparators go high. Monostable multivibrators are used on the output of the comparators to lengthen the high pulses. When all of the pulses from the monostable multivibrators are high at the same time, an AND gate output goes high. This high pulse activates the door opener. PMID:8329601

1993-01-01

308

An PB?-73C vacuum spark gap with a control circuit based on an inductive energy storage  

British Library Electronic Table of Contents (United Kingdom)

The design and operating principle of a small (50 mm in diameter and 100 mm in height) ???-73C vacuum spark gap are described. It is shown that it can be efficiently switched using a control circuit with a low (?900 V) supply voltage, which is based on an inductive energy storage and a diode opening switch that forms a high-voltage igniting pulse with a rise time of nanosecond duration. The ???-73C switching process is investigated at different rise times of igniting voltage pulses and different igniting current amplitudes. The results of tests of the spark gap operating in regimes of switching current pulses with an amplitude of 12 kA and a rise time of 800 ns are presented.

2011-01-01

309

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

310

A laser reflector for multi-bunch gamma conversions in a {gamma}{gamma} collider  

Energy Technology Data Exchange (ETDEWEB)

One of the main challenges for a high energy {gamma}{gamma} collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).

1995-02-01

311

A laser reflector for multi-bunch gamma conversions in a #gamma##gamma# collider  

International Nuclear Information System (INIS)

One of the main challenges for a high energy #gamma##gamma# collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).

312

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are described. copyright 1997 American Institute of Physics.

313

Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' performed by SKB ...

2005-12-15

314

Treatment of proliferative haemangiomas with the 585 nm pulsed dye laser.  

Science.gov (United States)

Haemangiomas usually develop within the first few weeks of life, most regressing spontaneously before the age of 7 years. Some may ulcerate or compromise a vital function, in which case systemic corticosteroids, surgery or radiotherapy may be helpful. All of these treatment modalities are associated with significant morbidity. Treatment with the 585 nm flashlamp pulsed dye laser is safe and effective in the management of superficial vascular malformations. We report seven patients, under 12 months of age, who presented with proliferative haemangiomas, causing functional impairment. Ulcerated lesions were present in four patients. The patients were treated with the 585 nm pulsed dye laser (fluences 7.0-9.25 J/cm2), at intervals of 4-8 weeks. All of the lesions showed a significant reduction in size, together with improvement in the colour and integrity of the overlying skin. Treatment with the 585 nm pulsed dye laser should ...

1996-04-01

315

Study to reduce laser-induced breakdown spectroscopy measurement uncertainty using plasma characteristic parameters  

Energy Technology Data Exchange (ETDEWEB)

Using standard brass alloy samples, an approach to reduce the laser-induced breakdown spectroscopy measurement uncertainty was tested and proved. Two important parameters for plasma characterization, the plasma temperature and the electron density, were applied to minimize the signal uncertainties due to uncontrollable experimental parameter variations. Results show that for the pulse-to-pulse analysis, the signal fluctuations can be significantly reduced by utilizing the plasma characteristic information. The major source for the single pulse fluctuations is the redistribution of the characteristic line at different temperatures according to the Boltzmann distribution under LTE. The change of the degree of ionization also contributes to the signal fluctuations. For the multi-pulse analysis, due to the nonlinear relationship between the plasma temperature and the line intensity, it is not applicable to utilize the Boltzmann ...

2010-07-15

316

Streptococcus pneumoniae Isolates with Reduced Susceptibility to Ciprofloxacin in Spain: Clonal Diversity and Appearance of Ciprofloxacin-Resistant Epidemic Clones  

UK PubMed Central (United Kingdom)

Analysis of the pulsed-field gel electrophoretic profiles of 82 pneumococcal isolates with reduced susceptibility to ciprofloxacin (RSC) and of 90 co-occurring susceptible isolates indicates a considerable...Full Text Available

2001-10-01

317

SCALER WITH RESOLUTION TIME EQUAL TO 10 NANOSECONDS  

Science.gov (United States)

In systems of fast decimal counters, there are three problems to be resolved: to study a bistable having a short switching time, to form with the aid of three bistables a circuit divisible by 5, and to normalize the input pulses. The solutions to these problems for the nonsecond scaler are presented. (J.S.R.)

1960-01-01

318

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

319

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...

2000-01-01

320

Program Solicitation  

Science.gov (United States)

Technologies for materials, processes, and manufacturing that will provide safe, .... advanced energy conversion techniques, and pulsed inductive and ... duration antimatter storage and transportation, and methods for utilizing ...... EVA systems can be found in the EVA Technology Roadmap of the EVA Project Plan. ...

321

New neutron simulation capabilities provided by the Sandia Pulse Reactor (SPR-III) and the Upgraded Annular Core Pulse Reactor (ACPR)  

Science.gov (United States)

The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which enhances the neutron exposure capabilities over those of the former ACPR Facility.

1978-07-01

322

Mode-locked YAG-Nd ring laser with unidirectional stimulated emission  

Energy Technology Data Exchange (ETDEWEB)

The traveling-wave mode in ring lasers is achieved by two methods: by a reversing mirror, and by using an intracavity nonreciprocal device. This paper is devoted to realization of the traveling-wave mode in a mode-locked YAG-Nd ring laser by a method proposed by Tomov et al. This method uses two intracavity Q-switches. In mode-locked operation, pulses are generated that can be considered short compared with the period of modulation T = L/C (where L is the length of the perimeter of the cavity). Analysis shows that if the shift of the switching signals corresponds to the time of travel of a light pulse between Q-switches, the pulse in one direction will pass the Q-switches at instants of zero losses, while losses in the other direction will be maximized for a distance between Q-switches of L/4, and will be zero for a distance L/2. Experimental verification of the proposed method gave unidirectional lasing with an intensity ...

1981-05-01

323

Measurement of cosmic ray neutron spectrum at sea level  

International Nuclear Information System (INIS)

The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).

324

MRI features of epidural extramedullary hematopoiesis  

Energy Technology Data Exchange (ETDEWEB)

A case of {beta}-thalassemia intermedia with spinal cord compression due to extramedullary hematopoiesis, which was successfully treated by blood transfusion, is presented. Emphasis was made on the MRI appearance of extramedullary hematopoiesis on different pulse sequences. The theories that aimed to explain the involvement of the epidural space by extramedullary hematopoiesis are discussed.

2000-07-01

325

J4P Evaluation of Externally Heated Pulsed MPD Thruster Cathodes  

Science.gov (United States)

twenty 350 V, 2.5 mF aluminum electrolytic capacitors with 10.8 mH inductors made of multi-strand wire. The PFN discharge was controlled using an silicon ...

326

Institute of Plasma Physics, Academy of Sciences of the Czech Republic  

International Nuclear Information System (INIS)

The major activities of the various Institute's departments are highlighted. The following departments are included: (i) Tokamak; (ii) Pulse plasma systems; (iii) Thermal plasma; (iv) Materials engineering; (v) Laser plasma; and (vi) Optical diagnosis. (P.A.)

327

Initial stage of localized corrosion in artificial pits formed with photon rupture on Zn-5 mass% Al alloy-coated steel  

International Nuclear Information System (INIS)

The photon rupture method, by which oxide film and metal are removed by focused pulsed Nd-YAG laser beam irradiation, was applied to form artificial micro-pits in Zn-5 mass% Al alloy-coated steel. The zinc alloy-coated layer was removed by pulsed laser irradiation treatment for about one second in a neutral buffer solution with NaCl. The rest potential transient with the laser treatment was measured. In the early stage of the laser treatment the rest potential of zinc alloy-coated steel changed to the negative direction immediately after every irradiation of a laser pulse and then returned to the previous value. However, after the steel substrate was exposed to the solution, the rest potential moved to the positive direction immediately after every irradiation of a laser pulse and then returned to the previous value. The amplitude and duration of the potential change after the laser irradiation ...

2007-05-01

328

Improvement of a Dendritic Cell-Based Therapeutic Cancer Vaccine with Components of Toxoplasma gondii?  

UK PubMed Central (United Kingdom)

The use of dendritic cells (DCs) as a cellular adjuvant is a promising approach to the immunotherapy of cancer. It has previously been demonstrated that DCs pulsed ex vivo with Toxoplasma gondii...Full Text Available

2009-10-01

329

High Power, High Repetition Rate, Diode-Pumped, Solid State Laser ...  

Science.gov (United States)

Also, this laster will employ an acousto-optic Q-switch which will allow repetition rates greater than 50 kHz at reduced pulse energy. ...

330

Energetic constraints on the creation of cell membrane pores by magnetic particles.  

UK PubMed Central (United Kingdom)

Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available

1996-08-01

331

Efficient modeling for pulsed activation in inertial fusion energy reactors  

International Nuclear Information System (INIS)

First structural wall material (FSW) materials in inertial fusion energy (IFE) power reactors will be irradiated under typical repetition rates of 1-10 Hz, for an operation time as long as the total reactor lifetime. The main objective of the present work is to determine whether a continuous-pulsed (CP) approach can be an efficient method in modeling the pulsed activation process for operating conditions of FSW materials. The accuracy and practicability of this method was investigated both analytically and (for reaction/decay chains of two and three nuclides) by computational simulation. It was found that CP modeling is an accurate and practical method for calculating the neutron-activation of FSW materials. Its use is recommended instead of the equivalent steady-state method or the exact pulsed modeling. Moreover, the applicability of this method to components of an IFE power plant subject to repetition rates lower than ...

2000-11-01

332

Drift compression and final focus of intense heavy ion beams  

Energy Technology Data Exchange (ETDEWEB)

The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.

2003-05-01

333

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

334

Developmental Changes in Pituitary Adenylate Cyclase Activating Polypeptide Expression during the Perinatal Period: Possible Role in Fetal Gonadotroph Regulation  

UK PubMed Central (United Kingdom)

Normal reproductive functioning may require secretion of LH independently of FSH. Variation in GnRH pulse frequency and inhibin negative feedback are mechanisms for differential gonadotropin regulation;...Full Text Available

2009-10-01

335

Behaviour of atomic oxygen in a pulsed dielectric barrier discharge measured by laser-induced fluorescence  

International Nuclear Information System (INIS)

Atomic oxygen is measured in a pulsed dielectric barrier discharge (DBD) using two-photon absorption laser-induced fluorescence (TALIF). The ground-level atomic oxygen is excited to the 3p "3P state by two-photon absorption at 226 nm. Negative (-40 kV) or positive (+30 kV) pulsed DBD occurs in an O_2-N_2 mixture at atmospheric pressure. The pulse width of the DBD current is approximately 50 ns. The TALIF experiment shows that the decay rate of atomic oxygen increases linearly with O_2 concentration. This result proves that atomic oxygen decays mainly by the third-body reaction, O + O_2 + M #-># O_3 + M. The rate coefficient of the third-body reaction is estimated to be 2.2 x 10"-"3"4 cm"6 s"-"1 in the negative DBD and 0.89 x 10"-"3"4 cm"6 s"-"1 in the positive DBD. It is shown that the decay rate of atomic oxygen increases linearly with humidity. This can explain the well-known fact that ozone production in DBD is ...

2005-08-21

336

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

337

An 802.11 Wireless Blood Pulse-Oximetry System for Medical Response to Disasters  

UK PubMed Central (United Kingdom)

In a mass casualty situation, medical personnel at the disaster site and other field treatment settings may need to monitor the vital signs of hundreds of seriously injured patients with minimal staffing....Full Text Available

2005-01-01

338

A chemical-modification approach to the olfactory code. Studies with a thiol-specific reagent  

UK PubMed Central (United Kingdom)

The effects of thiol-specific reagents on the amplitude of the electro-olfactogram (E.O.G.) responses elicited from frog olfactory mucosa by pulses of odorant vapours was studied. The impermeant thiol-specific...Full Text Available

1978-12-15

339

Yttrium Calcium Oxyborate for high average power frequency doubling and OPCPA  

Science.gov (United States)

Significant progress has been achieved recently in the growth of Yttrium Calcium Oxyborate (YCOB) crystals. Boules have been grown capable of producing large aperture nonlinear crystal plates suitable for high average power frequency conversion or optical parametric chirped pulse amplification (OPCPA). With a large aperture (5.5 cm x 8.5 cm) YCOB crystal we have demonstrated a record 227 W of 523.5nm light (22.7 J/pulse, 10 Hz, 14 ns). We have also demonstrated the applicability of YCOB for 1053 nm OPCPA.

2006-06-20

340

Tunable VUV generation by anti-Stokes stimulated Raman conversion of XeCl laser radiation  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on the results of experiments into efficient higher-order anti-Stokes Raman conversion of tunable short-pulse XeCl laser radiation. The maximum output energy of the pumping laser, in which the radiation of a frequency-doubled dye laser is amplified by two XeCl laser amplifiers, is 55 mJ with a pulse duration of 1 ns FWHM. Using hydrogen gas as a Raman medium, a series of anti-Stokes lines up to the 12th order (121.5 nm) is generated in the vacuum ultraviolet (VUV) region. 16 references.

1987-06-01

341

The successful treatment of lupus pernio with the flashlamp pulsed dye laser.  

Science.gov (United States)

Lupus pernio of the nose is the most characteristic cutaneous lesion of sarcoidosis. It is cosmetically disfiguring and can be the cause of significant morbidity. In particular, the affected skin is often red or purple due to increased vasculature. It is particularly resistant to both surgical and medical therapy. We describe a patient with lupus pernio affecting her nose, which showed a dramatic improvement following treatment with the pulse dye laser (PDL). A biopsy taken after treatment showed the continued presence of sarcoidal granulomas. We therefore feel that treatment with the PDL is an effective tool in improving the cosmetic appearance of lupus pernio, but does not influence the underlying disease process. PMID:11360426

1999-01-01

342

Superconducting magnetic and inertial energy pulsed power systems  

International Nuclear Information System (INIS)

Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.

1975-07-15

343

Simulation of Pulsed Neutron Activation using a CFD code  

International Nuclear Information System (INIS)

Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed

2008-09-14

344

Preliminary Study of Plasma Stream Interaction with Tungsten Target within RPI-IBIS Facility  

International Nuclear Information System (INIS)

The paper presents results of experimental research on the interaction of a pulsed plasma-ion stream with a tungsten (W) target. The pulsed hydrogen plasma was produced within the RPI-IBIS (Multi-Rod Plasma Injector) facility at IPJ in Swierk. Measurements were carried out by means of optical spectroscopy and corpuscular diagnostic techniques. For experiments with the W-target the operational conditions (so-called PID mode) were chosen when a clean hydrogen plasma stream was generated. Attention was paid to the identification of WI and WII spectral lines.

2006-01-01

345

Polysilicon TFT fabrication on plastic substrates  

Energy Technology Data Exchange (ETDEWEB)

Processing techniques utilizing low temperature depositions and pulsed lasers allow the fabrication of polysilicon thin film transistors (TFT`s) on plastic substrates. By limiting the silicon, SiO2, and aluminum deposition temperatures to 100(degrees)C, and by using pulsed laser crystallization and doping of the silicon, we have demonstrated functioning polysilicon TFT`s fabricated on polyester substrates with channel mobilities of up to 7.5 cm2/V-sec and Ion/Ioff current ratios of up to 1x10(to the 6th power).

1997-08-06

346

Photochemical generation of E' centre from Si-H in amorphous SiO2 under pulsed ultraviolet laser radiation  

CERN Document Server

In situ optical absorption spectroscopy was used to study the generation of E' centres in amorphous SiO_2 occurring by photo-induced breaking of Si-H groups under 4.7eV pulsed laser radiation. The dependence from laser intensity of the defect generation rate is consistent with a two-photon mechanism for Si-H rupture, while the growth and the saturation of the defects are conditioned by their concurrent annealing due to reaction with mobile hydrogen arising from the same precursor. A rate equation is proposed to model the kinetics of the defects and tested on experimental data.

2006-01-01

347

Performance optimization of the Packard 2000 CA/LL liquid scintillation counter for "1"4C dating  

International Nuclear Information System (INIS)

The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).

348

Multilayer ultra high gradient insulator technology  

Energy Technology Data Exchange (ETDEWEB)

We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.

1998-03-27

349

Monte Carlo Uncertainty Analyses of Pulsed Activation in the National Ignition Facility Gunite Shielding  

International Nuclear Information System (INIS)

The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.

2003-05-01

350

Microstructure Characterization of Magnetic-Pulse-Welded AA 6061-T6 by Electron Backscattered Diffraction  

Energy Technology Data Exchange (ETDEWEB)

The grain boundary crystallographic misorientations of magnetic-pulse-welded (MPW) aluminum alloy (AA) 6061-T6 in linear and tubular configurations were examined using the electron backscattered diffraction (EBSD) technique. A refined structure of heavily deformed grains with higher grain boundary angles was observed in linear welds. Significant spalling was observed away from the joints, in the interior of tubular welds. The results show the complex interaction of shock waves with the materials during this impact welding process.

2008-08-01

351

Micropulse Lidar (MPL) Handbook  

Energy Technology Data Exchange (ETDEWEB)

The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.

2006-05-01

352

Integrated disease management of ascochyta blight in pulse crops  

British Library Electronic Table of Contents (United Kingdom)

Ascochyta blight causes significant yield loss in pulse crops worldwide. Integrated disease management is essential to take advantage of cultivars with partial resistance to this disease. The most effective practices, established by decades of research, use a combination of disease-free seed, destruction or avoidance of inoculum sources, manipulation of sowing dates, seed and foliar fungicides, and cultivars with improved resistance. An understanding of the pathosystems and the inter-relationship between host, pathogen and the environment is essential to be able to make correct decisions for disease control without compromising the agronomic or economic ideal. For individual pathosystems, some components of the integrated management principles may need to be given greater consideration tha...

2007-01-01

353

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

354

Influence of UMTS mobile phone microwave fields on the muscular system; Einfluss von Mikrowellenfeldern des UMTS Mobilfunks auf das muskulaere System  

Energy Technology Data Exchange (ETDEWEB)

Two hypotheses are in the centre of this investigation, on the one hand the question, whether microwaves as exogenous fields alone are able to stimulate human muscle cells above-threshold, and on the other hand, whether microwaves as conditioning to cathodical electrical pulses can modify the excitation threshold and form. No excitation through the application of microwaves alone can be introduced at any subject. The conditioning of above-threshold cathodical electrical pulses with UMTS-microwaves leads not to a transgression of the threshold or the electrical muscle response (EMG) depending on the amplitude, the duration or the dose rate. (orig.)

2004-07-01

355

Improved, chirped acousto-optic q switch. [Patent application  

Science.gov (United States)

An improved acousto-optic laser Q-switch uses a chirped fm pulse in the acousto-optic cell to diffract and focus the input beam into a resonating high-Q mode. When the rf acoustic pulse is not wholly within the cell, the beam is diverted to the output. A reflective surface is placed on the cell to yield only one output beam and to yield a retroflective beam back into the cavity for a high Q condition whenever a correctly generated chirp acoustic wave is in the proper postion within the cell.

1977-01-24

356

Grid-controlled plasma cathodes  

International Nuclear Information System (INIS)

Experiments are described on a plasma cathode with biased grids to prevent entry of ions into the electron extraction gap. The cathode has potential applications to the generation of high-current pulsed electron beams. Operation at 20 A/cm"2 is theoretically possible. The source combines the low average power consumption of a plasma cathode with many of the attractive features of thermionic cathodes, such as space-charge-limited extractor gap electron flow, fast turn-on, and no diode closure. Initial experiments are reported at the 2 A/cm"2 level for pulse lengths to 160 #mu#s.

357

Generation and detection of superstrong shock waves during ablation of an aluminum surface by intense femtosecond laser pulses  

British Library Electronic Table of Contents (United Kingdom)

Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.

2011-01-01

358

Field emission dark current of technical metallic electrodes  

International Nuclear Information System (INIS)

In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.

2007-04-21

359

Electromagnetic coupling of high-altitude, nuclear electromagnetic pulses  

International Nuclear Information System (INIS)

We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.

1984-11-01

360

Effect of isopropyl alcohol on the surface localization and recombination of conduction-band electrons in Degussa P25 TiO_2. A pulse-radiolysis time-resolved microwave conductivity study  

International Nuclear Information System (INIS)

Conduction-band electrons, formed by pulse radiolysis of Degussa P25 TiO_2 particles, have been monitored by time-resolved microwave conductivity and found to undergo equilibrium localization and eventual recombination at the particle surface. In the presence of isopropyl alcohol recombination is retarded due to surface hole scavenging. The particle bulk can then be pumped with mobile electrons, which survive for seconds.

361

A new method for the analysis of infrared stimulated luminescence data from potassium feldspars  

International Nuclear Information System (INIS)

A new method is described for the analysis of high precision pulse annealing data obtained using IRSL measurements on potassium feldspars using a Risoe reader. Presenting the data as the percentage of the signal lost per annealing phase permits more detailed comparisons to be made between samples. In addition, it is possible to directly compare the temperatures at which the TL and IRSL signals are released, thus giving information about the relationship between them. This method of analysis is applied to pulse annealing data for natural, irradiated, preheated and IR bleached aliquots. (author).

1993-07-01

362

Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study  

British Library Electronic Table of Contents (United Kingdom)

AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...

2011-01-01

363

The diagnosis of inflammatory muscular and vascular conditions using MRT with STIR sequences  

International Nuclear Information System (INIS)

The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2 weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. Amongst 49 patients in whom the suspected ...

364

The 2001 Superoutburst of WZ Sagittae  

CERN Document Server

We report the results of a worldwide campaign to observe WZ Sagittae during its 2001 superoutburst. After a 23-year slumber at V=15.5, the star rose within 2 days to a peak brightness of 8.2, and showed a main eruption lasting 25 days. The return to quiescence was punctuated by 12 small eruptions, of ~1 mag amplitude and 2 day recurrence time; these "echo outbursts" are of uncertain origin, but somewhat resemble the normal outbursts of dwarf novae. After 52 days, the star began a slow decline to quiescence. Periodic waves in the light curve closely followed the pattern seen in the 1978 superoutburst: a strong orbital signal dominated the first 12 days, followed by a powerful /common superhump/ at 0.05721(5) d, 0.92(8)% longer than P_orb. The latter endured for at least 90 days, although probably mutating into a "late" superhump with a slightly longer mean period [0.05736(5) d]. The superhump appeared to follow familiar rules for such phenomena in dwarf novae, with ...

2002-01-01

365

News from the world; Echos du monde  

Energy Technology Data Exchange (ETDEWEB)

This document gathers a series of very short articles concerning nuclear industry around the world. Areva company is investing 30 million euros in its Chalon-Saint-Marcel plant, it is the consequence of the extension of service life of nuclear power plants in the Usa. Areva holds 40% of the American market concerning the replacement of steam generators and 50% of that concerning the replacement of closure heads. The Obrigheim nuclear power plant was definitely closed down on may 2004, this decommissioning is a step forward in the German policy of progressively stepping out of nuclear energy. Chinese authorities are willing to construct 40 nuclear reactors in 15 years, despite that, the contribution of nuclear energy to the generation of electricity will reach only 4% in 2020. In 2007 Cea will begin the construction works of a new research reactor (Jules Horowitz reactor) in the Cadarache site. Prices of the yellow cake have been going up during the last years: from 9 dollar the pound ...

2005-04-01

366

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

367

Mining ethical issues: the new prohibitionists  

Energy Technology Data Exchange (ETDEWEB)

The mining and energy industry is under assault today for reasons that have less to do with alleged technical failures and much more to do with ethical complaints about a rate of growth in population that industrial products from mining resources have made possible. The political agendas of Western industrialized nations have been driven during the past quarter century by those whose social philosophy advocates a new ethic of biocentric equality, whereby humans must be forced to being `living as if Nature mattered`. A Green ethic requires that `a violent, plundering humankind` must abandon its alleged rape of the earth and derive its ethical norms from pre-existing ecosystemic harmonies to preserve a fragile and precarious balance existing in Nature. From the perspective of history, there is nothing new about such complaints, current complaints about the use of fossil fuels and pollution from mining, echo similar complaints in past periods. Current Green thinking ...

1997-10-01

368

MRT in differentiation between tumour and implant material in the postoperative sella. Differenzierung zwischen Tumor und Implantatmaterial in der postoperativen Sella mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T[sub 1] weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of examination for hypophyseal tumours to ...

1993-06-01

369

MRT in differentiation between tumour and implant material in the postoperative sella  

International Nuclear Information System (INIS)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T_1 weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of examination for hypophyseal tumours to ...

370

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation  

International Nuclear Information System (INIS)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor invasion ...

371

Two-gigawatt burst-mode operation of the intense microwave prototype (IMP) free-electron laser (FEL) for the microwave tokamak experiment (MTX)  

Energy Technology Data Exchange (ETDEWEB)

The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to ...

1993-10-06

372

The effect of pulse voltage and capacitance on biosorption of uranium by biomass derived from whiskey distillery spent wash  

Energy Technology Data Exchange (ETDEWEB)

Biosorption of uranium by residual biomass from The Old Bushmill`s Distillery Co. Ltd., Bushmills, Co. Antrim, Northern Ireland, following exposure to short and intense electric pulses has been examined. The biomass was prepared from the distillery spent wash and consisted of non-viable yeast and bacterial cells. As shown previously, untreated biomass had a maximum biosorption capacity of 170 mg uranium/g dry weight biomass. When biosorption reactions were placed between two electrodes and exposed to electric pulses with field strengths ranging from 1.25-3.25 kV/cm at a capacitance of 25 {mu}F, biosorption increased from 170 mg of uranium to 275 mg uranium/g dry weight biomass. The data were obtained from biosorption isotherm analyses and taken as the degree of biosorption at residual uranium concentrations of 3 mM. In addition, when the capacitance of the electric pulses increased from 0.25 {mu}F to 25 {mu}F at a fixed ...

1999-01-01

373

Preliminary activation calculations for the PDX tokamak  

Energy Technology Data Exchange (ETDEWEB)

Activation dose rates have been computed for the Poloidal Divertor Experiment Tokamak at the Princeton Plasma Physics Laboratory. Dose rates were computed in one-dimensional (cylindrical) geometry using the ANISN S/sub n/ transport theory code and the DKR radioactivity code. The EPR (DLC37F) 121-group coupled neutron-gamma cross section library was used with ANISN. For DKR, the 46-group neutron library of DCDLIB was employed. Dose rates were calculated for 1 minute, 1 hour, 6 hours, 24 hours, 1 week, and 1 month following a single pulse yielding 10/sup 15/ neutrons and for 2 hypothetical pulsing sequences. First, it was assumed that 10 pulses were conducted each day (1 hour apart) for 5 days. Second, it was assumed that 100 pulses were conducted each day (6 minutes apart) for 5 days. It was found that /sup 56/Mn and /sup 64/Cu are the main contributors to the dose at short time periods after shutdown, ...

1980-10-01

374

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of ...

2008-02-01

375

Effects of holmium laser on dental structure in vivo: thermal evaluation and histological analysis on pulpal tissue; Efeitos in vivo do laser de holmio em estrutura dental: monitoracao termica e analise histologica do tecido pulpar  

Energy Technology Data Exchange (ETDEWEB)

Previous in vitro studies have demonstrated that Ho:YLF laser is capable of inducing physical and chemical changes on dental surfaces treated for caries prevention. The temperature in the pulp chamber was in vitro evaluated to as a function of the power and frequency of the laser irradiation. The purpose of this work is to verify the occurrence of pulp inflammation after Ho:YLF laser irradiation using different parameters in rabbits' teeth. The premolars and molars of ten rabbits (NZB) were divided in two groups according to the irradiation energy values of a Ho:YLF laser prototype operating at 2.065{mu}m wave length, frequency of O,5Hz and pulse length of 250{mu}s. An group A teeth were irradiated with using ten pulses of 334mJ/pulse of a Ho:YLF laser prototype operating at O.5Hz, and group B, with 512mJ/pulse. Animals were killed by transcardiac perfusion and the samples were prepared for ...

2001-07-01

376

Development and use of localized arc filament plasma actuators for high-speed flow control  

International Nuclear Information System (INIS)

The paper discusses recent results on the development of localized arc filament plasma actuators and their use in controlling high-speed and high Reynolds number jet flows. Multiple plasma actuators (up to 8) are controlled using a custom-built 8-channel high-voltage pulsed plasma generator. The plasma generator independently controls pulse repetition rate (0-200 kHz), duty cycle and phase for each individual actuator. Current and voltage measurements demonstrated the power consumption of each actuator to be quite low (20 W at 20% duty cycle). Emission spectroscopy temperature measurements in the pulsed arc filament showed rapid temperature increase over the first 10-20 ?s of arc operation, from below 1000 deg. C to up to about 2000 deg. C. At longer discharge pulse durations, 20-100 ?s, the plasma temperature levels off at approximately 2000 deg. C. Modelling calculations using an unsteady, ...

2007-02-07

377

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted ...

2009-08-15

378

The magnetoresonance operation of microwiggler on the piezoelectrics with a strong magnetic guide field  

Energy Technology Data Exchange (ETDEWEB)

We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).

1995-12-31

379

Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber  

Energy Technology Data Exchange (ETDEWEB)

A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as NO{sub x}. were reduced about 50%. The ...

1997-12-31

380

Propagation of guided waves in aircraft structure  

International Nuclear Information System (INIS)

The potential of ultrasonic guided modes for use in global structural health monitoring of aging metallic aircraft can only be realized if the modes selected are able to propagate over a reasonable distance. This work studies the propagation of different modes through fuselage structure by means of mode analysis, finite element modeling and experimental measurement. Beginning with the case of a simple skin panel, the paper examines propagation across a set of structural features representing a typical monocoque fuselage and considers the effect of overlying sealant layers, bonded and sealed joints, paint layers and tapering skin. With the exception of the fundamental symmetric mode at very low frequency, no mode was found that could propagate across all features with an effective attenuation of less than 40 dB/m. This makes global monitoring of a fuselage structure using a sparse array of transducers very difficult. However, more local monitoring is possible and ...

2000-05-23

381

Physics through the 1990s: scientific interfaces and technological applications  

Energy Technology Data Exchange (ETDEWEB)

The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and many chapters contain recommendations regarding funding, ...

1986-01-01

382

Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea  

Energy Technology Data Exchange (ETDEWEB)

An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed boundary layer. Both fast- ...

1998-07-01

383

Elastic properties and structural studies on some zinc-borate glasses derived from ultrasonic, FT-IR and X-ray techniques  

International Nuclear Information System (INIS)

Glasses in the system (1 - x) [29Na2O- 4Al2O3- 67B2O3]- xZnO (0 ? x ? 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N4 values (fraction of tetrahedral coordinated boron atoms), and substitution of longer bond lengths of Zn-O in place of shorter B-O bond. The results indicate that ...

2009-05-05

384

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative characterization of ...

2009-12-01

385

Current status and future plan of JMTR Hot Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) nondestructive evaluation using ultrasonic wave and infrared thermography for the quantitative ...

1999-08-01

386

Achievement report for fiscal 1998. Research and development of a multi-plant maintenance system (the first year); 1998 nendo seika hokokusho. Odanteki maintenance gijutsu no kenkyu kaihatsu (dai 1 nendo)  

Energy Technology Data Exchange (ETDEWEB)

This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a lubrication control system, and an anomaly diagnostic system using ultrasonic waves. ...

1999-03-01

387

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...

1998-02-01

388

A novel drug and gene co-delivery system based on Poly(epsilon-caprolactone)-Poly(ethylene glycol)-Poly(epsilon-caprolactone) grafted polyethyleneimine micelle.  

Science.gov (United States)

In this paper, we prepared a novel cationic self-assembled micelle from poly(epsilon-caprolactone)-poly(ethyl glycol)-poly(epsilon-caprolactone) grafted polyethyleneimine (PCEC-g-PEI). The PCEC-g-PEI micelles, formed by self-assembly method, had mean particle size of ca. 82 nm and zeta potential of +22.5 mV at 37 degrees C, and could efficiently transfer pGFP into HEK293 cells in vitro. Meanwhile, as a model hydrophobic chemotherapeutic drug, honokiol was loaded into PCEC-g-PEI micelles by direct dissolution method assisted by ultrasonication. The honokiol loaded cationic PCEC-g-PEI micelles could effectively adsorb DNA onto its surface, while it could release honokiol in an extended period in vitro. This study demonstrated a novel DNA and hydrophobic chemotherapeutic drug co-delivery system. PMID:21121283

2010-12-01

389

A comparison of truncated total least squares with Tikhonov regularization in imaging by ultrasound inverse scattering  

International Nuclear Information System (INIS)

For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...

2003-08-07

390

State of the art in high-power microwaves: An overview  

Energy Technology Data Exchange (ETDEWEB)

In the two decades since the presentation of the first experimental results, the study of high-power microwaves (HPM) has aimed at the production of microwave pulses with ever higher peak power and ever larger energy content. Drawing on the electrical pulsed power and relativistic electron beam technologies, a mix of sources have produced power levels in excess of 1 GW and pulse energies of tens to a thousand joules in both the centimeter and millimeter wavelength ranges. The potential for military applications of such powerful bursts became a major driving force for substantial research programs -- and considerable advancements -- in the United States and the former Soviet Union. The end of the Cold War and a reexamination of national priorities has diminished the momentum of military HPM development in these countries. Nevertheless, the field hasn`t reached its limits, in capability or applicability, and one sees at ...

1993-12-01

391

Pulse height response of Si surface barrier detectors to 5-70 MeV heavy ions  

Energy Technology Data Exchange (ETDEWEB)

An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alpha particle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of ...

1992-04-01

392

Molecular-beam/surface-science apparatus for state-resolved chemisorption studies using pulsed-laser preparation  

International Nuclear Information System (INIS)

We describe a new apparatus that combines pulsed laser excitation in a molecular beam with surface-science methods for preparation of clean single-crystal surfaces and detection of adsorbates to enable state-selected studies of gas-surface reaction dynamics. Reactant molecules are prepared in specific vibrationally excited states via overtone pumping using tunable, narrow-band laser radiation. The collision-free environment of the molecular beam prevents relaxation of the prepared molecules before impact on the target surface and enables complete control over the collision energy and incidence angle. Chemisorption products are detected after a given deposition time by Auger electron spectroscopy. To achieve sufficient beam flux of state-selected reactant molecules for product detection by standard surface-science techniques, we use a high-intensity, short-pulse molecular-beam source matched to the low duty cycle of the ...

2003-09-01

393

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and ...

394

Gaussian pulse decomposition: an intuitive model of electrocardiogram waveforms.  

Science.gov (United States)

This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization method is used to fit a portion of the ECG waveform with a single Gaussian pulse, which is then subtracted from the ECG waveform. The process iterates on the resulting residual waveform until the normalized mean square error is below an acceptable level. Three different minimization methods were compared for their applicability to the ChAD algorithm; the Nelder-Mead simplex method was found to be more noise-tolerant than the Newton-Raphson method or the steepest descent method. Using morphologically different ECG waveforms from the MIT-BIH arrhythmia database, it was demonstrated that the ChAD algorithm is capable ...

395

Controlling Charge and Current Neutralization of an Ion Beam Pulse in a Background Plasma by Application of a Solenoidal Magnetic Field I: Weak Magnetic Field Limit  

Energy Technology Data Exchange (ETDEWEB)

Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ?ce > ?pe?b, where ?ce = e?/mec is the electron gyrofrequency, ?pe is the electron plasma frequency, and ...

2008-10-10

396

rf system for the Los Alamos free-electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 ..mu..s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2/sup 0/, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-..mu..s pulses. Each tube has ...

1983-01-01

397

rf system for the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2_0, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each tube has delivered over ...

1983-03-21

398

The effects of high-intensity pulsed electromagnetic field on proliferation and differentiation of neural stem cells of neonatal rats in vitro.  

Science.gov (United States)

The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of the growth of neural stem cells (PHPEMS groups was the same as that in control group (P>0.05). It was suggested that 0.1 Hz, 5 pulses stimulation of HPEMS within ...

2009-12-29

399

The effect of relative humidity on ozone production by corona discharge in oxygen or air - A numerical simulation - Part 2: Air  

Science.gov (United States)

The simulation of the temporal evolution of the various neutral gaseous species studied (O, O{sub 3}, H, OH, HO{sub 2}, H{sub 2}O{sub 2}, N, NO, NO{sub 2}, NO{sub 3}, N{sub 2}O, N{sub 2}O{sub 5}, HNO{sub 2}, and HNO{sub 3}) use corona effects. The physical conditions of the discharge were used. The reactions take place in dry or humid air, after the dissociation of O{sub 2}, N{sub 2}, and H{sub 2}O by an electronic pulse. When water vapor is present, there is a probability of production of H{sub 2}O{sub 2}, HNO{sub 2}, and HNO{sub 3} in air. Temperature and humidity have cumulative effects. With multiple pulses, the O{sub 3} maximal concentration is obtained for a limited number of pulses.

400

The RF system for the Los Alamos free electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are + or - 1/2"0, and + or - 1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each tube has ...

401

The BPX electrical power system  

International Nuclear Information System (INIS)

This paper reports on the Burning Plasma Experiment (BPX) which when operating at a toroidal field of 8.1 tesla and a plasma current of 10.6 megamps, requires peak power of 1235 megawatts and total pulse energy of over 21 gigajoules. These requirements are twice and over four times the corresponding figures for the Tokamak Fusion Test Reactor (TFTR), respectively. The design of the BPX power system has evolved, along with the tokamak, over a period of several years and has included studies of several alternative approaches. The reapplication of the existing TFTR power and energy facilities has been basic to all approaches. Among the new sources of pulse power and energy that have been considered are: direct utility grid pulsing, new flywheel units, and lead-acid storage batteries. The toroidal field power requirements are the greatest of the BPX subsystems and, fortunately, are sufficiently free of dynamics to allow the ...

1991-10-03

402

TPX Neutral Beam Injection System design  

International Nuclear Information System (INIS)

The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems and the major modification of replacing the beamline-torus duct ...

1993-10-11

403

Surface morphology of thin lysozyme films produced by matrix-assisted pulsed laser evaporation (MAPLE)  

Energy Technology Data Exchange (ETDEWEB)

Thin films of the protein, lysozyme, have been deposited by the matrix-assisted pulsed laser evaporation (MAPLE) technique. Frozen targets of 0.3-1.0 wt.% lysozyme dissolved in ultrapure water were irradiated by laser light at 355 nm with a fluence of 2 J/cm{sup 2}. The surface quality of the thin lysozyme films of different thickness deposited on 7 mm x 7 mm Si-<1 0 0>-wafers was investigated with scanning electron microscopy and atomic force microscopy. Already at comparatively low thickness, {approx}20 nm, the substrate is covered by intact lysozyme molecules and fragments. The concentration of lysozyme in the ice matrix apparently does not play any significant role for the morphology of the film. The morphology obtained with MAPLE has been compared with results for direct laser irradiation of a pressed lysozyme sample (i.e. pulsed laser deposition (PLD))

2007-12-15

404

Simulations of a ring resonator free-electron laser  

International Nuclear Information System (INIS)

In this paper, a relatively high gain (#approx =# 25 to 40 percent) free-electron laser (FEL) with an optical ring resonator is simulated using the code FELEX. The laser system corresponds to the ''burst mode'' FEL scheduled for operation at Boeing Aerospace Company in 1988. The ring consists of paraboloids, grazing incidence by hyperboloids, and a grating rhomb. The wiggler is 5 m in length and has an adjustable taper, while the electron beam is produced by an RF linac. The optical elements of the ring together with the FEL interaction in the wiggler are modeled in three spatial dimensions to investigate the system from start-up to saturation. Both single frequency and finite pulse simulations are performed. The study illustrates the necessity of mode matching the loaded resonator to maximize the extraction efficiency. The mode matching is necessary because the FEL interaction significantly alters the optical beam focus position and Rayleigh range. The ...

405

Regeneration of CO poisoned PEM fuel cells by periodic pulsed oxidation  

International Nuclear Information System (INIS)

CO poisoning is a major issue when reformate is used as a fuel in PEM fuel cells. Normally it is necessary to reduce the CO to very low levels (#approx#5 ppm) and CO tolerant catalysts, such as Pt-Ru, are often employed. As an alternative approach, we have studied the use of pulsed oxidation for the regeneration of CO poisoned cells. Results are presented for the regeneration of Pt and Pt-Ru anodes in a PEM fuel cell fed with CO concentrations as high as 10,000 ppm. The results show periodic removal of CO from the catalyst surface by pulsed oxidation can increase the average cell potential and increase overall efficiency. A method for enhancing the performance of a fuel cell stack using a microprocessor-based Fuel Cell Health Manager (FCHM) has been developed. The results of a cost/benefit analysis for the use of a FCHM on a 4 kW residential fuel cell system are presented. (author)

2004-09-25

406

Pulse Shapes From Rapidly-Rotating Neutron Stars: Equatorial Photon Orbits  

CERN Document Server

We demonstrate that fitted values of stellar radius obtained by fitting theoretical light curves to observations of millisecond period X-ray pulsars can significantly depend on the method used to calculate the light curves. The worst-case errors in the fitted radius are evaluated by restricting ourselves to the case of light emitted and received in the equatorial plane of a rapidly-rotating neutron star. First, using an approximate flux which is adapted to the one-dimensional nature of such an emission region, we show how pulse shapes can be constructed using an exact spacetime metric and fully accounting for time-delay effects. We compare this to a method which approximates the exterior spacetime of the star by the Schwarzschild metric, inserts special relativistic effects by hand, and neglects time-delay effects. By comparing these methods, we show that there are significant differences in these methods for some applications, for example ...

2005-01-01

407

Photo-induced transformation of close Frenkel pairs in strontium fluoride  

International Nuclear Information System (INIS)

Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation from I to II and vice versa. It is suggested that the component I corresponds to ...

408

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...

2006-09-01

409

Measurements of radio propagation in rock salt for the detection of high-energy neutrinos  

CERN Document Server

We present measurements of the transmission of radio/microwave pulses through salt in the Cote Blanche salt mine operated by the North American Salt Company in St. Mary Parish, Louisiana. These results are from data taken in the southwestern region of the 1500 ft. (457 m) deep level of the mine on our third and most recent visit to the mine. We transmitted and received a fast, high-power, broadband pulse from within three vertical boreholes that were drilled to depths of 100 ft. (30 m) and 200 ft. below the 1500 ft. level using three different pairs of dipole antennas whose bandwidths span 125 to 900 MHz. By measuring the relative strength of the received pulses between boreholes with separations of 50 m and 169 m, we deduce the attenuation of the signal attributed to the salt medium. We fit the frequency dependence of the attenuation to a power law and find the best fit field attenuation lengths to be 93 \\pm 7 m at 150 ...

2008-01-01

410

Large area electron beam pumped krypton fluoride laser amplifier  

International Nuclear Information System (INIS)

Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a daily basis for laser-target experiments. ...

411

High voltage high brightness electron accelerator with MITL voltage adder coupled to foilless diode  

International Nuclear Information System (INIS)

The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.

1995-10-13

412

Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor  

International Nuclear Information System (INIS)

Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min"-"1), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O_2 mixtures with the maximum efficiency (energy ...

2005-02-07

413

FEA Analysis of AP-0 Target Hall Collection Lens (Current Design)  

Energy Technology Data Exchange (ETDEWEB)

The AP-0 Target Hall Collection Lens is a pulsed device which focuses anti-protons just downstream of the Target. Since the angles at which the anti-protons depart the Target can be quite large, a very high focusing strength is required to maximize anti-proton capture into the downstream Debuncher Ring. The current design of the Collection Lens was designed to operate with a focusing gradient of 1,000 T/m. However, multiple failures of early devices resulted in lowering the normal operating gradient to about 750 T/m. At this gradient, the Lens design fares much better, lasting several million pulses, but ultimately still fails. A Finite Element Analysis (FEA) has been performed on this Collection Lens design to help determine the cause and/or nature of the failures. The Collection Lens magnetic field is created by passing high current through a central conductor cylinder. A uniform current distribution through the cylinder will create a ...

2001-06-22

414

Evaluation of the potential of pentachlorophenol degradation in soil by pulsed corona discharge plasma from soil characteristics.  

Science.gov (United States)

Chlorinated organics are frequently found as harmful soil contaminants and persisted for extended periods of time. A novel approach, named pulsed corona discharge plasma (PCDP), was employed for the degradation of pentachlorophenol (PCP) in soil. Experimental results showed that 87% of PCP could be smoothly removed in 60 min. Increasing pulse voltage, enhancing soil pH, lowering humic acid (HA) in soil and reducing granular size of the soil were found to be favorable for PCP degradation efficiency. Oxidation and physical processes simultaneously contributed to PCP removal in soil and ozone was the main factor in PCDP treatment. C-Cl bonds in PCP were cleaved during PCDP treatment by Fourier transform infrared spectroscopy (FTIR) analysis. The mineralization of PCP was confirmed by total organic carbon (TOC) and dechlorination analyses. The main intermediate products such as tetrachlorocatechol, tetrachlorohydroquinone, acetic acid, formic acid, ...

2010-04-15

415

Efficiency of ozone production by pulsed positive corona discharge in synthetic air  

International Nuclear Information System (INIS)

We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh"-"1 and 35-110 eV/molecule. (author)

2002-06-07

416

Development of CANDU Void Reactivity Uncertainty Evaluation Methodology  

International Nuclear Information System (INIS)

One of inherent characteristics of CANDU reactor is positive void reactivity in contrast to other pressurized light water reactors. During the large break loss of coolant accident, power pulse will be occurred during short time of early phase of accident due to positive void reactivity. However the duration of this power pulse is short, energy due to power pulse would be accumulated in the cladding material and will affect the peak cladding temperature or number of failed fuel elements. Recently, Canadian Nuclear Safety Commission (CNSC) indicated that the amount of void reactivity might be larger than the assumed values in safety analysis and this indication was based on the experimental data from ZED-2 facility. Based on that, the estimation of uncertainties due to the void reactivity during LBLOCA is the most important issue for CANDU safety analysis. In this study, a framework of uncertainty evaluation methodology for ...

2010-10-01

417

Demonstration and Optimization of a Drive Laser for an X-Band Photoinjector  

Energy Technology Data Exchange (ETDEWEB)

Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address observed shortcomings and ...

2009-04-17

418

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible ...

2009-06-17

419

Behavioral effects of exposure to the TEMPO high-power microwave system. Interim report, January-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of ...

1988-03-01

420

Application of conventional laser technology to gamma-gamma colliders  

International Nuclear Information System (INIS)

A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...

1994-03-28

421

Application of conventional laser technology to gamma-gamma colliders  

Energy Technology Data Exchange (ETDEWEB)

A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address ...

1995-02-01

422

Application of conventional laser technology to gamma-gamma colliders  

Energy Technology Data Exchange (ETDEWEB)

A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser ...

1995-02-01

423

Air breakdown induced by a high-power short-pulse microwave  

Energy Technology Data Exchange (ETDEWEB)

At Himeji Institute of Technology, the high power microwaves with the peak power of 20 MW, frequency of 12 GHz and pulse duration of 14 ns have been produced with a virtual cathode oscillator (vircator). These high power microwaves offer new applications in various fields. One problem in laser-triggered lightning experiment is the strong attenuation of laser energy by rain, cloud and laser-produced plasma. Microwaves propagate in thundercloud with small loss, and also are able to irradiate much extensive region of targets. In this paper, the fundamental experiment on the air breakdown induced by high power, short pulse microwaves is reported. The experimental setup of the vircator diode for microwave generation is shown. The typical evolution of diode voltage, electron beam current and microwave emission from the top in the course of time is shown. The experimental setup for microwave-induced air breakdown and the experimental procedure are ...

1996-05-01

424

Acute low-level microwave exposure and central cholinergic activity: studies on irradiation parameters  

Energy Technology Data Exchange (ETDEWEB)

Sodium-dependent high-affinity choline uptake was measured in the striatum, frontal cortex, hippocampus, and hypothalamus of rats after acute exposure (45 min) to pulsed (2 microseconds, 500 pps) or continuous-wave 2,450-MHz microwaves in cylindrical waveguides or miniature anechoic chambers. In all exposure conditions, the average whole-body specific absorption rate was at 0.6 W/kg. Decrease in choline uptake was observed in the frontal cortex after microwave exposure in all of the above irradiation conditions. Regardless of the exposure system used, hippocampal choline uptake was decreased after exposure to pulsed but not continuous-wave microwaves. Striatal choline uptake was decreased after exposure to either pulsed or continuous-wave microwaves in the miniature anechoic chamber. No significant change in hypothalamic choline uptake was observed under any of the exposure conditions studied. We conclude that depending on ...

1988-01-01

425

A nuclear powered pulsed inductive plasma accelerator as a viable propulsion concept for advanced OTV space applications  

International Nuclear Information System (INIS)

An electric propulsion concept suitable for delivering heavy payloads from low earth orbit (LEO) to high energy earth orbit is proposed. The system consists of a number of pulsed inductive plasma thrusters powered by a 100 kWe space nuclear power system. The pulsed plasma thruster is a relatively simple electrodeless device. It also exhibits adequate conversion to thrust power in the desired I sub sp regime of 1500 to 3000 seconds for optimal payload transfer from low earth to high earth orbit. Because of these features and the fact that the nuclear power unit will be capable of delivering sustained high power levels throughout the duration of any given mission, the system presented appears to be a very promising propulsion candidate for advanced orbital transfer vehicle (OTV) applications. An OTV, which makes use of this propulsion system and which has been designed to lift a 9000-lb payload into geosynchronous earth orbit, (GEO) is also ...

426

A high-intensity plasma-sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as ...

1989-01-01

427

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a ...

2007-10-29

428

Comparison of the argon tunable dye laser with the flashlamp pulsed dye laser in treatment of facial telangiectasia  

Science.gov (United States)

A prospective, side-by-side comparison study of two different lasers for the treatment of solar- induced telangiectasia was carried out in 14 patients at the Beckman Laser Institute and Medical Clinic. The argon tunable dye laser (Coherent, Palo Alto, Calif.) was used in the method modified from Orenstein and Nelson to completely treat discrete telangiectasias on one cheek. Specifically, the argon tunable dye laser (ATDL) was set at 0.7 - 0.8 watts, 585 nm wavelength, shutter-pulsed at 0.1 second duration with a spot size of 0.1 mm, and individual vessels were 'traced out' with 4X loupe magnification. Each patient's opposite cheek was then treated in the standard fashion with the flashlamp pulsed dye laser (Candela, Natick, Mass.) using a technique similar to Polla's et al. Specifically, the flashlamp pulsed dye laser (FPDL) was set at 585 nm wavelength, pulsed mode of 450 microseconds ...

1992-06-01

429

Wave formation mechanism in magnetic pulse welding  

British Library Electronic Table of Contents (United Kingdom)

Wavy interface morphology is observed in Magnetic Pulse Welding (MPW) similarly to that of the Explosion Welding process (EXW). It is recognized that interfacial waves are formed in a periodic manner and have well defined wavelength and amplitude. The phenomenon of wave formation in EXW has been subjected to extensive investigations in which empirical and numerical models have been published. In the present study, a wave formation mechanism for MPW is presented. This wave-creation mechanism was studied by evaluating the influence of sample geometry on wave morphology using stereoscopic optical microscopy. It was found that interfacial waves are formed in a Kelvin-Helmholtz instability mechanism. Reflected shock waves interact with the welding collision point at the weld interface, where in...

2010-01-01

430

Up-conversion luminescence saturation under pulsed excitation of erbium-doped, SiO_2-TiO_2 sol-gel powders  

International Nuclear Information System (INIS)

The intensity of erbium up-conversion luminescence could be limited by a saturation effect due to increased pump power. We studied the luminescence saturation of the 550 nm emission on erbium-doped, SiO_2-TiO_2 sol-gel powders under pulsed excitation at 979 and 1532 nm. From the latter, the up-converted luminescence intensity decreased with increasing excitation power, whereas no saturation was observed at 979 nm excitation. We proposed that the saturation effect is determined by the pump power, the erbium content and the lifetime of the corresponding first excited states at different pumping schemes.

2010-12-01

431

Time Characterization of High Density Gas Jet from a Pulsed Supersonic Nozzle via Laser Produced Plasma  

International Nuclear Information System (INIS)

A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.

2006-07-01

432

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

433

The response of clamped-clamped microbeams under mechanical shock  

British Library Electronic Table of Contents (United Kingdom)

We present modeling, simulation, and characterization for the dynamic response of clamped-clamped microbeams under mechanical shock. A Galerkin-based reduced-order model is utilized and its results are verified by comparing to finite-element results. The results indicate that the response of a microbeam to mechanical shock is inherently non-linear because of the dominating effect of mid-plane stretching. The effect of the shock pulse shape is investigated. It is concluded that the shape of the shock pulse can result in significant dynamic amplification in the response of the microbeam even in cases where the shock load is considered quasi-static.The combined effect of the electrostatic force and mechanical shock is investigated. The results show that this combined effect can lead to early ...

2007-01-01

434

The effects of high-intensity pulsed electromagnetic field on proliferation and differentiation of neural stem cells of neonatal rats in vitro  

British Library Electronic Table of Contents (United Kingdom)

Summary The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of ...

2009-01-01

435

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

436

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

437

The NIST/NRL free-electron laser facility  

International Nuclear Information System (INIS)

A free-electron laser (FEL) user facility is discussed. The FEL, which will be operated as an oscillator, will be driven by the electron beam of the racetrack microtron (RTM) that is nearing completion. Variation of the electron kinetic energy from 17 MeV to 185 MeV will permit the FEL wavelength to be tuned from 200 nm to 10 #mu#m. Performance will be enhanced by the high brightness, low energy spread, and continuous pulse nature of the RTM electron beam. The authors are designing a new injector to increase the peak current of the RTM. A 3.6-m undulator is under construction, and the 9-m optical cavity is under design. The FEL will emit a continuous train of 3-ps pulses at 66 MHz with an average power of 10--200 W, depending on the wavelength, and a peak power of up to several hundred kW. An experimental area is being prepared with up to five stations for research using the FEL beam.

1989-04-24

438

The Formation of the Low-sized High Density Plasma Structures in the Self-maintained Plasma-beam Discharge  

International Nuclear Information System (INIS)

The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.

2006-01-01

439

Temperature dependence of threshold current of injection lasers for short pulse excitation  

Energy Technology Data Exchange (ETDEWEB)

We report measurements of the temperature dependence of the threshold current of GaAs, 1.3-..mu..m InGaAsP, and 1.5-..mu..m InGaAsP double heterostructure lasers using short electrical pulses. T/sub 0/approx.200 K is observed for all the lasers. These high T/sub 0/ values show that the carrier density at threshold does not increase rapidly with increasing temperature in any of the lasers studied and thus the observed low cw T/sub 0/ of InGaAsP lasers is primarily due to a decrease of the carrier lifetime at threshold with increasing temperature.

1984-05-15

440

Surface modification of the pure iron by the pulse plasma nitriding: Application of a kinetic model  

Energy Technology Data Exchange (ETDEWEB)

In this work, the pulse plasma nitriding process of pure iron is modelled using a kinetic model derived from the Fick's laws. This approach based on the error function model allows to simulate the growth kinetics of a biphase configuration consisting of {gamma}'-Fe{sub 4}N{sub 1-x} and {epsilon}-Fe{sub 2-3}N iron nitrides under specified conditions. By coupling the kinetics data about the diffusivities of nitrogen in {alpha}-Fe, {gamma}' and {epsilon} phases to the thermodynamic description of the Fe-N phase diagram, it is possible to evaluate the kinetic constant at each growing phase interface, the thickness of nitrided layer, and predict the nitrogen concentration profiles. The comparison between the experimental and theoretical results shows the reliability of the simulation results.

2007-07-25

441

Surface modification of the pure iron by the pulse plasma nitriding: Application of a kinetic model  

International Nuclear Information System (INIS)

In this work, the pulse plasma nitriding process of pure iron is modelled using a kinetic model derived from the Fick's laws. This approach based on the error function model allows to simulate the growth kinetics of a biphase configuration consisting of #gamma#'-Fe_4N_1_-_x and #epsilon#-Fe_2_-_3N iron nitrides under specified conditions. By coupling the kinetics data about the diffusivities of nitrogen in #alpha#-Fe, #gamma#' and #epsilon# phases to the thermodynamic description of the Fe-N phase diagram, it is possible to evaluate the kinetic constant at each growing phase interface, the thickness of nitrided layer, and predict the nitrogen concentration profiles. The comparison between the experimental and theoretical results shows the reliability of the simulation results.

2007-07-25

442

Submegahertz linewidth at 240 GHz from an injection-locked free-electron laser  

International Nuclear Information System (INIS)

Radiation from an ultrastable 240 GHz solid state source has been injected, through an isolator, into the cavity of the University of California, Santa Barbara millimeter-wave free-electron laser (FEL). High-power FEL emission, normally distributed among many of the cavity's longitudinal modes, is concentrated into the single mode to which the solid state source has been tuned. The linewidth of the FEL emission is 0.5 MHz, consistent with the Fourier transform limit for the 2 #mu#s pulses. This demonstration of frequency-stable, ultranarrow-band FEL emission is a critical milestone on the road to FEL-based pulsed electron paramagnetic resonance spectroscopy.

2007-10-22

443

STATUS OF THE DIELECTRIC WALL ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

2009-04-22

444

Pulsed Radiofrequency Ablation for Residual and Phantom Limb Pain: A Case Series  

British Library Electronic Table of Contents (United Kingdom)

Abstract Residual limb pain (RLP) and phantom limb pain (PLP) can be debilitating and can prevent functional gains following amputation. High correlations have been reported between RLP and the stump neuromas following amputation. Many treatment methods including physical therapy, medications, and interventions, have been used with limited success. Pulsed radiofrequency ablation (PRFA) has shown promise in treating neuropathic pain because of the inhibition of evoked synaptic activity. We present 4 amputees who were treated with PRFA after failing conservative management for their RLP and PLP. All 4 patients underwent PRFA and demonstrated at least 80% relief of RLP for over 6 months. One patient reported a complete resolution of phantom sensation while another patient had significantly de...

2010-01-01

445

Pulse radiolysis studies on [Fe(CN)_6]"4"- - BrO_3"- - CN"-system in ethylene glycol - water solutions  

International Nuclear Information System (INIS)

Formation of oxidizing and reducing radicals was studied by pulse radiolysis of [Fe(CN)_6]"4"- - BrO_3"- - CN"- system in ethylene glycol - water solvent mixture. Oxidizing #centre dot#BrO_2 and BrO radicals formed by electron scavenging with #centre dot#BrO_2"- were identified and their reactions were investigated. The reaction of hydroxyl radicals with ethylene glycol leads to formation of reactive radicals with reducing properties and of compounds which reduce slowly in dark the ferricyanide formed in the reaction of #centre dot#BrO_2 radical with ferrocyanide. (author) 21 refs.; 7 figs.

1991-01-01

446

Propagation of pressure perturbations in bubbly air/water flows  

Energy Technology Data Exchange (ETDEWEB)

The propagation of acoustic pressure perturbations in an adiabatic low-quality air/water flow were investigated both theoretically and experimentally. A linearized dispersion model is correlated with data to extract information on the behavior of interfacial momentum transfer controlled by the virtual volume coefficient. The dispersion model is examined in limiting cases of low and high frequency and related to current models for critical flow velocity. Fourier decomposition techniques are employed to predict the dispersion of measured pressure pulses and to relate data for standing waves and propagating pulses. The dispersion model is based on a two-fluid model and is the most complete model available in the literature at this time. The dispersion data presented herein is also the best available to date for low frequency (i.e., frequencies less than bubble resonance) sound propagation in bubbly air/water mixtures.

1987-01-01

447

Programming resistive switching memory by a charged capacitor  

British Library Electronic Table of Contents (United Kingdom)

Resistive switching memory is a very promising technology for emerging nonvolatile memory applications. Generally, the switching behavior is triggered by a sweep or pulse voltage. In this paper, a charged capacitor is proposed to be used as the external electrical source to program a resistive switching element. From theoretical analyses based on a set behavior model, the capacitor approach can program the device efficiently. Compared with sweep or pulse mode, capacitor driving method can greatly reduce over-programming after the set event, and thus improve the resistance uniformity. The experimental results performed on Cu/ZrO2:Cu/Pt device support this conclusion quite well. The proposed methodology has great value for achieving a reliable resistive switching, which is important for high...

2011-01-01

448

Preparation of cost-effective Pt-Co electrodes by pulse electrodeposition for PEMFC electrocatalysts  

International Nuclear Information System (INIS)

Graphical abstract: - Abstract: Low loading platinum-cobalt (Pt-Co) cathode catalyst on a Nafion(Na+)-bonded carbon layer is fabricated by using galvanostatic pulse technique to show the advantage of electrodeposition for high utilization of catalyst in proton exchange membrane fuel cell (PEMFC). We observed that Pt-Co catalysts evenly exist on the surface of carbon electrode and its thickness is about 5.8 ?m, which is four times thinner than conventional Pt/C. Improved single cell power performance of Pt-Co cathode catalysts with a ratio of 3.2:1 compared with Pt/C is clearly presented.

2011-03-01

449

Performance following a 500-675 rad neutron pulse. Report for June 1981-January 1984  

Energy Technology Data Exchange (ETDEWEB)

A three-light, three-lever discrete avoidance behavioral task was initiated to study the effects of a 500-675 rad neutron pulse upon performance. Eight primates performed the task for 4 h(3.5 h postexposure) on exposure day and for 4 h on each of 3 d postexposure. For the exposure day, five subjects had a decrease in correct responses, seven had increased reaction times, and six experienced productive emesis within 3.5 hours postexposure. Although the performance degradations were not severe, these data suggest that the performance of time critical tasks could be significantly impaired.

1985-06-01

450

Performance Evaluation of Several Types of Pulsed Eddy Current Probes for Detecting Wall Thickness Reduction  

Science.gov (United States)

In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.

2010-02-01

451

Pencil-like mm-size electron beams produced with linear inductive voltage adders  

International Nuclear Information System (INIS)

We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.

452

Ozone production process in pulsed positive dielectric barrier discharge  

International Nuclear Information System (INIS)

The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O_2 + M #-># O_3 + M, is estimated to be 2.5 x 10"-"3"4 cm"6 s"-"1.

2007-01-07

453

One-electron redox reactions of pyrazolin-5-ones. A pulse radiolysis study of antipyrine and analogues  

Energy Technology Data Exchange (ETDEWEB)

One-electron oxidation of several derivatives of pyrazolin-5-one, including the drug antipyrine, were studied by pulse radiolysis of aqueous solutions. All the compounds were found to be oxidized by Br2 rapidly but considerably more slowly by weaker oxidants, such as peroxyl radicals. From redox equilibria using p-methoxyphenol and N,N,N',N'-tetramethyl-p-phenylenediamine as reference compounds, the one-electron oxidation potentials of the methyl-substituted 2-pyrazolin-5-ones were found to be in the range of 0.32-0.39 V versus normal hydrogen electrode. The relevance of these findings to the properties of the drug nafazatrom is discussed. Antipyrine was found to have a much higher oxidation potential, estimated as 1.2-1.5 V, which is rationalized on the basis of the phenyl substitution and lack of resonance stabilization of the radical cation.

1985-10-01

454

Observation of dust stream formation produced by low current, high voltage cathode spots  

International Nuclear Information System (INIS)

Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed during this process.

2004-04-01

455

Numerical simulation of a pulsed corona discharge plasma  

Science.gov (United States)

In this paper we study theoretically a pulsed corona discharge plasma in air at atmospheric pressure. A self consistent one-dimensional model, using a flux-corrected transport numerical scheme, is presented to achieve it. The charged particle kinetics in this model are described by one-dimensional continuity equations coupled with Poisson's equations. The spatio-temporal local field, charge density variations and the velocity profile of an ionizing front are calculated to describe the dynamical behavior of corona discharge plasmas. The simulation results of a wire-in-cylinder corona discharge plasma explain the physical mechanisms of discharge processes. These results may also be apply to obtain the optimizing parameters for designing the plasma reactor.

2001-10-01

456

Modulation of proton NMR free induction decay by spin diffusion  

Energy Technology Data Exchange (ETDEWEB)

The effects of spin diffusion on the free induction decay (FID) of protons associated with the noncrystalline domains of two polymers, polyethylene and blended Nylon 66 (ZYTEL-408), have been examined using Goldman--Shen NMR pulse sequence ((1/2)..pi..x-t/sub 0/-(1/2)..pi..x-bar-tau-(1/2)..pi..x-t). At tau< or approx. =100 ..mu..s, the FID is drastically distorted from the exponential form while at longer tau(tau> or approx. =500 ..mu..s) an exponential FID is observed; but its transverse spin relaxation rate is smaller than that of the FID obtained after a single (1/2)..pi..x pulse and approaches this value at the limit of large tau. These findings are interpreted in terms of the theory of rapid spin diffusion. The spatial variation in the spin relaxation rate within the noncrystalline domain is inferred.

1982-02-01

457

Mechanism of the accumulation effect in laser damage to polymers: appearance of microdamage due to an ionization absorption wave  

Energy Technology Data Exchange (ETDEWEB)

An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.

1984-04-01

458

Magnetic pulse welding (MPW); Magnetumformen - Fuegen und Schweissen (MPW)  

Energy Technology Data Exchange (ETDEWEB)

Magnetic pulse welding, a cold solid state bonding process, is becoming a viable replacement for conventional fusion welding processes and explosive welding. The process is presented here along with its fundamental equations and applications of similar and dissimilar welds are illustrated along with typical interface microstructures. (orig.) [German] Magnetimpuls-schweissen, ein Verbindungsverfahren im kalten Festzustand, wird ein funktionsfaehiger Ersatz fuer das herkoemmliche Schmelzschweissverfahren und das Explosionsschweissverfahren. Das Verfahren wird hier mit seinen grundlegenden Gleichungen vorgestellt, und Anwendungen von aehnlichen und unaehnlichen Schweissungen werden mit typischen Schnittstellen-Mikrostrukturen veranschaulicht. (orig.)

2001-07-01

459

Laser-generated PuO_2--UO_2 condensation aerosols  

International Nuclear Information System (INIS)

A 340-watt CO_2 laser is being used to generate PuO_2-UO_2 condensation aerosol from the surface of a Liquid Metal Fast Breeder Reactor (LMFBR) fuel pellet. A wide range of concentrations is achieved by varying the laser power, pulse width, and/or pulse period. The resulting aerosol is composed of branch chain-like aggregates, with the primary particle size ranging between 0.005 and 0.15 #mu#m. X-ray diffraction analyses show that these aerosols condense into a face-centered cubic crystal structure. The activity mean aerodynamic diameter (AMAD), for most power levels, is approximately 0.85 #mu#m with a geometric standard deviation of 1.5.

1977-05-01

460

Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation  

CERN Document Server

An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.

2010-01-01

461

Irradiation effect of high current pulsed electron beam on surface structure and mechanical properties of NiCoCrAlY  

International Nuclear Information System (INIS)

DZ4 substrates were coated with NiCoCrAlY by plasma spray and subsequently treated by high current pulsed electron beams(HCPEB) of different parameters. The surface microstructure, phase structure and high temperature oxidation resistance were studied. It has been shown that as a result of the HCPEB treatment the loose and rough structure remelted and the surface became smooth. Smooth microregion, craters and cracks appeared on the surface. The ?' phase manifolded and there was no visible thermal stress. The oxidation test at 900 degree C for 100 h showed that a more compact and successive ?-Al_2O_3 scale was formed on the surface of the samples after HCPEB irradiation, which improved the oxidation resistance of the NiCoCrAlY coatings obviously. (authors)

2009-09-01

462

Ion implantation into concave polymer surface  

Energy Technology Data Exchange (ETDEWEB)

A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation measurement shows that gas-barrier property enhances due to the ...

2006-01-15

463

Intermediate Strain-Rate Loading Experiments - Technique and Applications to Ceramics  

Energy Technology Data Exchange (ETDEWEB)

A new test methodology is described which allows access to loading rates that lie between split Hopkinson bar and shock-loading techniques. Gas gun experiments combined with velocity interferometry techniques have been used to experimentally determine the intermediate strain-rate loading behavior of Coors AD995 alumina and Cercom silicon-carbide rods. Graded-density materials have been used as impactors; thereby eliminating the tension states generated by the radial stress components during the loading phase. Results of these experiments demonstrate that the time-dependent stress pulse generated during impact allows an efficient transition from the initial uniaxial strain loading to a uniaxial stress state as the stress pulse propagates through the rod. This allows access to intermediate loading rates over 5 x 10{sup 3}/s to a few times 10{sup 4}/s.

1999-08-16

464

Interfacial ultrafine-grained structures on aluminum alloy 6061 joint and copper alloy 110 joint fabricated by magnetic pulse welding  

British Library Electronic Table of Contents (United Kingdom)

Magnetic pulse welding is a solid state impact welding process, similar to explosive welding, which produces metallurgical bond by oblique high-speed impact between two metal bodies. This violent impact removes the metal surface oxide layers and then joins the two atomic level clean metal surfaces together by the incidental compression pressure. The impact velocity is at 200?400?m/s and the being welded metal surface undergoes severe plastic deformation with strain rate in the order of 106?107?s?1. The ultrafine-grained structure was observed on the welded interface. This article studied two types of similar material lap joint interfaces and the base metals were aluminum alloy 6061 and copper alloy 110. Nano-indentation testing shows that the welded interfaces have significantly greater ha...

2010-01-01

465

Infrared bleaching of the thermoluminescence of four feldspars  

International Nuclear Information System (INIS)

This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse annealing results and the loss of TL due to IR exposure of the ...

1995-06-01

466

Impact of Collateral Damage to Endourologic Tools During Laser Lithotripsy???In Vitro Comparison of Three Different Clinical Laser Systems  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background and Purpose: During laser lithotripsy, working instruments are often in close proximity to the distal fiber tip and may be damaged accidentally or even intentionally. The aim of this study was to compare the amount of damage to a standard guidewire and the nitinol wires of endourologic retrieval baskets that were affected by three different clinically available laser systems. Materials and Methods: The impact of pulsed laser irradiation on a standard hydrophilic guidewire and a retrieval basket were investigated. One infrared (IR) laser system (holmium:yttrium-aluminum-garnet [Ho:YAG]: ????=???2100???nm) and two laser systems emitting light in the visible (VIS) spectral range (frequency-doubled double-pulse neodymium:YAG [FREDDY]: ????=???532???nm/1064???nm and flashl...

2011-01-01

467

Heteroepitaxial Growth of NSMO on Silicon by Pulsed Laser Deposition  

Energy Technology Data Exchange (ETDEWEB)

The following is the optimized pulsed laser deposition (PLD) procedure by which we prepared the final samples that were sent to LLNL. These samples are epitaxial multilayer structures of Si/YSZ/CeO/NSMO, where the abbreviations are explained in the following table. In this heterostructure, YSZ serves as a buffer layer to prevent deleterious chemical reactions, and also serves to de-oxygenate the amorphous SiO{sub 2} layer to generate a crystalline template for epitaxy. CeO and BTO serve as template layers to minimize the effects of thermal and lattice mismatch strains, respectively. More details on the buffer and template layer scheme are included in the manuscript [Yong et al., 2008] attached to this report.

2008-06-25

468

Gun requirements to achieve high field spheromaks  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a gun similar to that in the SSPX could demonstrate the high fields required for Pulsed Spheromak reactors merely by prolonging the pulse. Important considerations are choosing the voltage to exceed ohmic losses; designing the gun to avoid wasteful short-circuiting of current within the gun; and the injection efficiency factor, f, determined by the ''sag'' in the profile of {lambda} = {mu}{sub o}j/B. Typically f = 0.75 in experiments, giving an overall efficiency > 50 % if short-circuiting is avoided. Theoretical transport models agree qualitatively with the need for a finite gradient in h to pump in helicity by current-driven tearing modes and suggest that pressure-driven resistive modes would not compete with current-driven modes during a buildup to ohmic ignition.

1999-03-04

469

Free electron laser inertial thermonuclear synthesis  

International Nuclear Information System (INIS)

The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.

470

Effects of electric current pulse on stability of solid/liquid interface of Al-4.5wt.% Cu alloy during directional solidification  

British Library Electronic Table of Contents (United Kingdom)

This paper investigates the effects of the electric current pulse (ECP) on the interface stability of Al-4.5% Cu alloy during the directional solidification. Experimental results show both the cellular spacing and the mushy zone depth decrease with increasing current density, moreover, the solid-liquid interface morphology transforms from dendritic to cellular or even planar interface. The secondary dendrites are suppressed due to the homogeneous distribution of the solute and the increase of temperature gradient originated from ECP. The decrease of the cellular spacing results from branching of the cellular tip caused by Joule heat of the current exerting on cellular tip.

2007-01-01

471

Effect of On-Chip Magnetic Shielding for TES Microcalorimeters  

British Library Electronic Table of Contents (United Kingdom)

We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...

2008-01-01

472

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)

473

Direct patterning of complex oxides by pulsed laser deposition through stencils  

International Nuclear Information System (INIS)

The possibilities to grow isolated structures of complex oxides by pulsed laser deposition through stencils were investigated. A stencil consisting of a SiN membrane with apertures of several hundred nanometers embedded in a Si chip is placed in front of a heated substrate (up to 750 degrees Celsius). Deposition through these apertures results in resistless, direct patterning by local deposition of complex oxides like ferroelectric Lead Zirconate Titanate. The created isolated structures were analyzed by AFM imaging. Under-deposition, in this work called broadening, is inevitable during stencil deposition and is depending on deposition parameters, especially pressure. Different causes of broadening are mapped and discussed.

2007-04-01

474

Diffraction Experiments at the IBR-2 Pulsed Reactor with Methane Cold Neutron Source  

CERN Document Server

A new methane cold neutron source has been tested at the IBR-2 pulsed reactor at the Frank Laboratory of Neutron Physics. In a paper the results of experiments at neutron diffractometers HRFD and DN-2 which are placed at the IBR-2 from the methane moderator side are given. A comparison with the results obtained with the conventional water comb-like moderator is performed. The perspectives of the cold source for various kinds of neutron diffraction experiments, including atomic and magnetic structural analysis and real time experiments are discussed. It is shown, that for a huge number of the experiments which are performing at both HRFD and DN-2 the methane cold neutron source provides the better conditions than water comb-like moderator.

2000-01-01

475

Development of Plasma Technologies at IPP NSC KIPT  

International Nuclear Information System (INIS)

Plasma Technologies in Institute of Plasma Physics of the NSC KIPT are recently developed in the following directions. Material surfaces modification under their irradiation with pulsed plasma streams of different working gases. Besides traditional analysis of improvements of tribological characteristics and structural-phase changes of the modified layers recently we started investigations of material corrosions characteristic improvement under influence of pulsed plasma on the material surfaces. As to the surface coatings in arc discharges of Bulat type devices, new trends are related with multi-layers coatings, using Ti-AI-N coatings in cutting tools, using high frequency discharges or combined HF- and arc discharges for increasing the nomenclature of goods to be coated. Development of ozonators is respectively new area for IPP NSC KIPT. On the base of barrier high-frequency discharge there were developed a number of high efficiency ozonators ...

2001-09-19

476

Determining concentration distribution of admixture from count ratemeter response in continuous analyses  

International Nuclear Information System (INIS)

A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).

1983-01-01

477

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

478

Chinese research on high-power microwaves. Studies in Chinese Science  

Energy Technology Data Exchange (ETDEWEB)

The study examines advances in Chinese High Power Microwaves (HPM) research and its associated technologies: pulsed power, high-power microwave sources, and high-power microwave components. It draws from open literature published in Chinese and English, communication with US scholars who have visited China recently, and communication with Chinese researchers in the United States. The study is limited to frequencies ranging from 1 GHz to 300 GHz. It includes both high peak power microwaves and high average power microwaves. The technical review section of this study is ordered in technological sequence, starting with the pulsed-power systems required to form the intense relativistic electron beams, then assessing microwave source research and development, and finally discussing high-power microwave components.

1990-05-01

479

Cardiac Pacing: Memories of a Bygone Era  

British Library Electronic Table of Contents (United Kingdom)

The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...

2008-01-01

480

Capacity-coupled multidischarge for atmospheric plasma production  

International Nuclear Information System (INIS)

We propose a method of plasma production by capacity-coupled multidischarge (CCMD) at atmospheric pressure. The discharge gaps in the CCMD consist of a common electrode and a number of compact electrodes (CCE) which are directly coupled with small capacitors for quenching the discharge. A simple CCE structure is provided by a cylindrical capacitor, the inner conductor of which is used as a gap electrode. A short pulse discharge is observed to appear homogeneously at each CCE. A charge transfer for the single-pulsed discharge is 10-100 times as large as that of the conventional dielectric barrier discharge. A high efficiency of ozone production has been confirmed in the CCMD using O_2 gas. A device configuration of the CCMD is quite flexible with respect to its geometrical shape and size. The CCMD could be used to produce plasmas for various kinds of industrial applications at atmospheric pressure.

2003-12-29

481

>100 watt average power at 0.53 {mu}m with 25 ns, 2.5 kHz repetition rate pulses from a single power oscillator  

Energy Technology Data Exchange (ETDEWEB)

We have generated approximately 100 watts of frequency doubled light from the output of an electro-optically Q-switched, diode-pumped Nd:YAG slab laser oscillator operating at an average power of 200 watts (2.5 kHz repetition rate, 80 mJ/pulse, 25 ns pulsewidth). The Q-switch was a compensated z-axis propagation LiNbO{sub 3} electro-optic modulator, and the frequency conversion crystal was a thin slab of KTP. In addition, Q-switched operation at an average power of approximately 250 watts with 26 ns pulsewidths has been demonstrated.

1994-03-01

482

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse ...

2000-08-01

483

The feasibility study of hot cell decontamination by the PFC spray method  

International Nuclear Information System (INIS)

The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research ...

2008-01-01

484

The state of surface layers on lithium in modified non-aqueous media  

Energy Technology Data Exchange (ETDEWEB)

The state of lithium electrode surface after contact with triethylamine-modified propylene carbonate solutions of lithium perchlorate was studied using the pulse galvanostatic technique as well as methods of SIMS and electron microscopy. It was shown that amine added into the solutions stabilizes the state of lithium and prevents the formation of a secondary porous passive film on the lithium surface. Chemical composition of the primary film remains unchanged. Certain properties of passive films formed in electrolyte solutions studied were evaluated.

1995-04-01

485

The magnetopause  

Energy Technology Data Exchange (ETDEWEB)

A review of theoretical and observational research on the magnetopause during 1987-1990. Starting with recent work on magnetic reconnection, the review proceeds to magnetopause surface wave phenomena, including the controversy over the role of solar wind pressure pulses in the coupling process and in the mimicking of flux transfer events signatures, and finishes with the magnetopause structure and associated wave phenomena. Recent advances in computer modeling of the magnetopause and the pertinent processes are also discussed. 108 refs.

1991-01-01

486

The THz Radiation from Undulator  

Science.gov (United States)

The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.

2010-02-03

487

The JET (Joint European Torus) multipellet launcher and fueling of JET plasmas by multipellet injection  

Energy Technology Data Exchange (ETDEWEB)

A new multipellet long-pulse plasma fueling system is in operation on JET. In the initial experimental phase, a variety of plasma density profile shapes have been produced with peak to average values ranging up to 2.5 and peak plasma density up to 1.2 )times) 10/sup 20/m/sup )minus/3). 7 refs., 4 figs

1988-01-01

488

Single-mode 30 MW CO/sub 2/ laser system for 16. mu. m Raman scattering in parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

A CO/sub 2/ laser chain able to supply approx.=30 MW on a single mode TEM/sub 00/ is described. The coupling of a modified Lumonics 101 module with a low-pressure cell constitues the oscillator and two further Lumonics 103 stages two amplifiers. The final pulse achieves the energy of 4.0 J with 90% of this energy in a peak of 100 ns FWHM.

1983-01-11

489

Monitoring interfacial dynamics by pulsed laser techniques. [Annual report  

Energy Technology Data Exchange (ETDEWEB)

Goal was developing optical methods for study of dynamic processes at the electrode/electrolyte interface. In the past year, optical second harmonic generation was used for time-resolved measurements of thallium deposition on Cu(111). The studies of carrier dynamics in photo-excited materials have involved both steady-state and picosecond time-resolved luminescence measurements following photoexcitation of the semiconductor material.

1992-12-31

490

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

491

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

492

Fifty successful years of the Institute of Plasma Physics, Academy of Sciences of the Czech Republic  

International Nuclear Information System (INIS)

The history of the Czech Institute of Plasma Physics is highlighted. The article is structured as follows: Cyclic accelerators; Interaction of an external high-frequency field and high-temperature plasma - the tokamak; Interaction of an external high-frequency field and high-temperature plasma - pulse plasma systems; Low-temperature plasma - plasma technologies and new materials; Laser plasma - PALS; Optical diagnosis; and Teaching, conferences and international cooperation. (P.A.)

493

Ferromagnetism in Mn-doped GaAs layers: Effects of laser annealing  

Energy Technology Data Exchange (ETDEWEB)

The properties of Mn-doped GaAs layers grown by laser deposition were investigated with measurements of Hall effect and magneto-optical Kerr effect (MOKE). The electrical and magnetic parameters of the layers were defined by growth temperature and quantity of sputtered Mn. It was shown that room-temperature ferromagnetism is revealed by MOKE and, after ruby laser 25 ns pulse annealing, by Hall effect measurements.

2006-05-15

494

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for ...

495

Development of a retrofit coal combustor for industrial applications  

Energy Technology Data Exchange (ETDEWEB)

In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.

1987-01-01

496

Creep performance of welded joints of type alloy 800 HT; Zeitstandfestigkeit von Schweissverbindungen des Typs Alloy 800 HT  

Energy Technology Data Exchange (ETDEWEB)

The results of the creep performance studies at temperatures from 700-1000 C with welds of alloy 800 HT, the manual shielded metal arc welds made with Githerm 85 and Grini 209 filler metals, as well as the MIG pulsed arc welds made with the Nicrofer S 206 and Nicrofer S 5520 filler metals, proved to be in very good agreement with the calculated characteristic values published on VdTUeV sheet 434 in comparative assessments based on creep values valid for a service period of 10 000 hours. The MIG pulsed arc weld made with the Nicrofer S 5520 filler metal achieved by far the best results and strength values comparable to those of the base material, whereas the values of the other welds were corresponding to calculated strength values of the base material reduced by 20%. (orig./CB) [Deutsch] Die im Temperaturbereich von 700-1000 C an Alloy 800 HT und den Elektrodenhandschweissverbindungen mit den Schweisszusaetzen Gritherm 85 und Grini 209, sowie ...

1999-10-01

497

Chamber technology concepts for inertial fusion energy: Three recent examples  

Energy Technology Data Exchange (ETDEWEB)

The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting structures from fusion neutrons thereby ...

1997-02-27

498

A multi-megawatt X-band solid state microwave switch  

Energy Technology Data Exchange (ETDEWEB)

The authors present design methodology and initial experimental results for a high power microwave switch. The switch is designed for application to the pulse compression system associated with the Next Linear Collider Test Accelerator (NLCTA). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. They explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission.

1995-12-31