WorldWideScience
1

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

2

Evaluation of ultrasonic indications in steam turbine rotors by fracture mechanics analysis  

International Nuclear Information System (INIS)

The report summarizes ten years of experience in the analysis and evaluation of ultrasonic testing data measured in turbine and generator rotors. Apart from the information on type, position, size and distribution of flaws, the expert knowledge achieved in an interpretation of ultrasonic signals yields further insight, as e.g.: - Confirmation of assumptions taken as a basis for fracture-mechanical analysis of these flaws with regard to crack initiation and crack growth under low-cycle fatigue conditions (O=0.7-1 Rp 0.2, N<25.000 growth in length); - enhanced information on a correlation of ultrasonic testing data with the real flaw size. (orig.).

1990-10-04

3

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

4

Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials  

International Nuclear Information System (INIS)

It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.

2007-12-17

5

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented ...

2009-12-01

6

Generation and control of sound bullets with a nonlinear acoustic lens  

UK PubMed Central (United Kingdom)

Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available

2010-04-20

7

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer ...

2008-05-07

8

Mobile and Marine Robotics  

Science.gov (United States)

University research group with research areas: * Land based and submersible autonomous robots, (UUVs: AUVs and ROVs); * Controllers, electronics, sensor design and fusion, motion control; * Guidance and navigation of underwater vehicles; * AI, neural networks, fuzzy logic, subsumption control, behaviour based control; * Optical fibre and ultrasonic sensors for proximal object detection; * Robot arm control, visual servoing; * Imaging sonar applications; * Simulator development: UUV simulator; imaging sonar simulator; Aircraft/flight simulator.

2007-07-01

9

THE EFFECTS OF ONE MEGACYCLE ULTRASONIC ...  

Science.gov (United States)

... ULTRASONIC VIBRATION TO PORTLAND CEMENT-WATER PASTE REDUCES THE ULTIMATE COMPRESSIVE STRENGTH OF MORTARS ...

1959-09-09

10

Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction  

International Nuclear Information System (INIS)

An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.

2005-04-09

11

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

12

ISR; A database for symbolic processing in computer vision  

Energy Technology Data Exchange (ETDEWEB)

Computer vision imposes unique requirements on the representation and manipulation of image data and knowledge. At a vision system's lowest level are sensors that represent an image with purely numeric image arrays, while at the highest level are semantic world models that provide the final interpretation of the scene. In between are thousands of intermediate descriptions, many of which must be repeatedly accessed and processed during interpretation. In this article, the authors describe a representation and management system for use at the intermediate (symbolic) level of vision. Based on database management methodology, the intermediate symbolic representation (ISR) mediates access to intermediate-level vision data and forms an active interface to the higher-level inference processes that construct an image's ...

1989-12-01

13

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

14

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

15

Road Interpretation for Driver Assistance Based on an Early Cognitive Vision System  

DEFF Research Database (Denmark)

In this work, we address the problem of road interpretation for driver assistance based on an early cognitive vision system. The structure of a road and the relevant traf?c are interpreted in terms of ego-motion estimation of the car, independently moving objects on the road, lane markers and large scale maps of the road. We make use of temporal and spatial disambiguation mechanisms to increase the reliability of visually extracted 2D and 3D information. This information is then used to interpret the layout of the road by using lane markers that are detected via Bayesian reasoning. We also estimate the ego-motion of the car which is used to create large scale maps of the road and also to detect independently moving objects. Sample results for the presented algorithms are shown on a stereo image sequence, that has been collected from a structured road.

2009-01-01

16

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

17

Addition of methyl cellulose enema to double-contrast barium imaging of sigmoid diverticulosis  

Energy Technology Data Exchange (ETDEWEB)

Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).

1997-01-01

18

Dynamically focussed array  

Energy Technology Data Exchange (ETDEWEB)

An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a continuously varying ...

1981-07-07

19

An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.  

Science.gov (United States)

A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial ...

2010-07-19

20

A comparison of truncated total least squares with Tikhonov regularization in imaging by ultrasound inverse scattering  

International Nuclear Information System (INIS)

For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image ...

2003-08-07

21

Structural studies of some phospho-borate glasses using ultrasonic pulse-echo technique, DSC and IR spectroscopy  

International Nuclear Information System (INIS)

Glasses in the system (95-x) [0.25 Na2O-0.75 B2O3]-x P2O5-5 Fe2O3 (0?x?15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P2O5 on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P2O5. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P2O5 content as a second network former. These results are interpreted in terms of the replacement of the diborate units with B-O-B bridges by phosphate units with non-bridging oxygens ...

2009-06-01

22

Elastic properties and structural studies on some zinc-borate glasses derived from ultrasonic, FT-IR and X-ray techniques  

International Nuclear Information System (INIS)

Glasses in the system (1 - x) [29Na2O- 4Al2O3- 67B2O3]- xZnO (0 ? x ? 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N4 values (fraction of tetrahedral coordinated boron atoms), and substitution of longer bond lengths of Zn-O in place of shorter B-O bond. The ...

2009-05-05

23

Imaging pharmacodynamics in oncology. The potential significance of 'flares'  

International Nuclear Information System (INIS)

The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically ...

2010-04-01

24

Direct digital radiography vs conventional radiography of thoracic spine: a comparative study  

International Nuclear Information System (INIS)

Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...

2005-09-01

25

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it ...

1998-02-01

26

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work ...

2001-07-01

27

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...

1987-12-01

28

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...

1987-01-01

29

High resolution transmission electron microscopy of partial states of oxygen order in YBa_2Cu_3O_z  

International Nuclear Information System (INIS)

This paper reports on high resolution electron microscopy used to investigate the effect of electron irradiation induced oxygen loss on the states of partial order in YBa_2Cu_3O_z. Contrast effects visible in the [001] zone image as a result of the degree of the out-of-plane correlation of these ordered states are investigated. Using statistical simulations to aid in the analysis of the HREM images, an interpretation based on a kinetically limited evolution of the variation of long range [001] ordering is proposed.

1990-04-16

30

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

31

A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography  

International Nuclear Information System (INIS)

Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all ...

1999-11-01

32

An imaging comparison of three depth migration algorithms on Foothills datasets  

Energy Technology Data Exchange (ETDEWEB)

Three popular imaging methods were used to carry out seismic migration from the Alberta foothills: Kirchhoff integral, reverse-time and explicit finite-difference migration methods. The imaging comparisons of reverse-time, Kirchhoff and f-x post-stack depth migration leads to the following conclusions. All of the three migration methods can provide acceptable and well-imaged intermediate results on the simplest model. Post-stack migration was not very sensitive to the accuracy of the velocity field once a reliable structural stack was available. With respect to the imaging accuracy and calculation cost, the Kirchhoff migration method seemed to be superior to reverse-time and f-x migration algorithms because its results on different kinds of velocity cases were basically kept coherent and consistent with the velocity model given by Mobil. Because of the lack of an accurate velocity field, reverse-time ...

1999-11-01

33

An imaging comparison of three depth migration algorithms on Foothills datasets  

Energy Technology Data Exchange (ETDEWEB)

Three popular imaging methods were used to carry out seismic migration from the Alberta foothills: Kirchhoff integral, reverse-time and explicit finite-difference migration methods. The imaging comparisons of reverse-time, Kirchhoff and f-x post-stack depth migration leads to the following conclusions. All of the three migration methods can provide acceptable and well-imaged intermediate results on the simplest model. Post-stack migration was not very sensitive to the accuracy of the velocity field once a reliable structural stack was available. With respect to the imaging accuracy and calculation cost, the Kirchhoff migration method seemed to be superior to reverse-time and f-x migration algorithms because its results on different kinds of velocity cases were basically kept coherent and consistent with the velocity model given by Mobil. Because of the lack of an accurate velocity field, reverse-time ...

1999-01-01

34

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain structures and to determine the consistency of ...

2007-01-01

35

Ultrasonic Acoustic Emissions from the Sapwood of Cedar and Hemlock 1  

UK PubMed Central (United Kingdom)

Measurements are reported of ultrasonic acoustic emissions (AEs) measured from sapwood samples of Thuja occidentalis L. and Tsuga canadensis (L.) Carr. during air dehydration....Full Text Available

1984-08-01

36

Ultrasonic enhancement of heat transfer on narrow surface  

Energy Technology Data Exchange (ETDEWEB)

Ultrasonic enhancement of heat transfer on a narrow surface was measured by changing the width of the surface from 8 to 0.1 mm. Ultrasonic power of 600 W with a frequency of 40 kHz was used. Heat transfer on the narrow surface without ultrasonic vibration was correlated by the experimental equation for a thin wire. The cavitation intensity was measured by the cavitation erosion loss of an aluminum foil of 15 [mu]m thickness. The effects of acoustic streaming and cavitation were separated by this measurement. Heat transfer by acoustic streaming was predicted through forced convection. Enhancement by cavitation was explained by the turbulence thermal conductivity of the microjets.

1994-06-01

37

Ultrasonic piezoelectric transducer that forms a specified directivity pattern  

Energy Technology Data Exchange (ETDEWEB)

Methods of designing ultrasonic piezoelectric transducers in accord with a specified directivity pattern are analyzed and general formulas are presented for the design problem. As an example, the pressure distribution on the working surface of a circular piezoelectric transducer is determined that is capable of forming a narrow weakly divergent beam. Experimental results are presented with respected to ultrasonic fields that support the theoretical conclusions.

1989-03-01

38

Evaluation of phased array UT conditions using ultrasonic visualization technique  

International Nuclear Information System (INIS)

Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)

2008-07-01

39

Effect of ultrasonic waves on boiling heat transfer. 2  

International Nuclear Information System (INIS)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-05-01

40

Effect of ultrasonic waves on boiling heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-07-01

41

Effect of ultrasonic energy on Mn-Zn ferrite powder behavior  

Energy Technology Data Exchange (ETDEWEB)

Effect of ultrasonic-wave irradiation on the Mn-Zn ferrite powder suspension prepared by solid-state reaction and alcoholic dehydration methods was investigated. Size, distribution, and morphology of the powders prepared at different temperatures were examined, as a function of irradiation time. It was observed that the powders were reduced in size by ultrasonic energy through distinct routes. 8 refs., 7 figs., 1 tab.

1999-07-01

42

Performance study of teleradiology network systems with CRT monitors. ROC analysis of an observation study of simulated lung nodules  

International Nuclear Information System (INIS)

To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the ...

43

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells  

Energy Technology Data Exchange (ETDEWEB)

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength ...

2009-11-15

44

Use of SPOT satellite imagery to obtain GIS input for oil spill models  

Energy Technology Data Exchange (ETDEWEB)

Satellite imagery is a cost-effective tool for creating and updating basemaps of coastal zones, especially where existing maps and aerial photographs are unavailable, are out-of-date, or provide limited information. Reliable maps of coastal zones are particularly important for oil spill modelling programs. Color IR (multispectral) images with 20m x 20m ground resolution and black & white (panchromatic) images with 10m x 10m ground resolution of many coastlines around the globe have been acquired from 1986 to present by SPOT Image Corporation. We have digitally merged same-day SPOT panchromatic and multispectral imagery to provide maximum spatial resolution and permit excellent color differentiation of coastal zone features. This combination adequately discriminates individual features, including pipelines, offshore platforms, storage tanks, jetties, and shoreline type. The SPOT images were ...

1995-04-01

45

A high accuracy ultrasonic measurement method for nondestructive evaluation of residual stress in welded pipings  

Energy Technology Data Exchange (ETDEWEB)

Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The ...

1995-08-01

46

Near-surface 3D reflections seismic survey; Sanjigen senso hanshaho jishin tansa  

Energy Technology Data Exchange (ETDEWEB)

Faults are being actively investigated across Japan since the Great Hanshin-Awaji Earthquake. Discussed in this report is the application of the 3D near-surface reflection seismic survey in big cities. Data from trenching and drilling is used for the geological interpretation of the surroundings of a fault, and the reflection seismic survey is used to identify the position, etc., of the fault. In this article, when the results obtained from the experimental field are examined, it is found that the conventional 2D imaging reflection survey betrays the limit of its capability when the geological structure is complicated, that the 3D reflection seismic survey, on the contrary, is capable of high-precision imaging and, when augmented by drilling, etc., becomes capable of a more detailed interpretation, and that it also contributes effectively to the improvement of local disaster prevention in big cities. ...

1997-05-27

47

Computer image analysis of wear debris for machine condition monitoring and fault diagnosis  

Energy Technology Data Exchange (ETDEWEB)

Whenever moving surfaces interact, wear particles are produced. Microscopic examination of the morphology of such wear debris is an accepted method for machine condition monitoring and fault diagnosis. Wear particle analysis has not, however, been widely accepted in industry because it is dependent on expert interpretation of particle morphology and relies on subjective assessment criteria. Consequently, the methods are time consuming and expensive and are not always consistent. The use of automated computer image analysis systems to assess the morphology of debris promises to overcome these limitations by making the methods more time and cost efficient, and also more consistent and effective. The first step required for automation of the analysis procedure is to develop objective criteria for assessing the wear particle morphology. Numerical parameters to describe the morphology have been developed and are outlined in this paper. A system ...

1995-03-01

48

Semantic network array processor and its applications to image understanding  

Energy Technology Data Exchange (ETDEWEB)

The problems in computer vision range from edge detection and segmentation at the lowest level to the problem of cognition at the highest level. This correspondence describes the organization and operation of a semantic network array processor (SNAP) as applicable to high level computer vision problems. The architecture consists of an array of identical cells each containing a content addressable memory, microprogram control, and a communication unit. The applications discussed in this paper are the two general techniques, discrete relaxation and dynamic programming. While the discrete relaxation is discussed with reference to scene labeling and edge interpretation, the dynamic programming is tuned for stereo.

1987-01-01

49

Lack of awareness of symptoms in people with dementia: the structural and functional basis  

British Library Electronic Table of Contents (United Kingdom)

AbstractObjective To review studies investigating the brain correlates of unawareness of cognitive and behavioural symptoms in people with dementia. Design A detailed search of the literature was conducted to include all the peer-reviewed studies published in English aimed at identifying the structural or functional brain correspondents of unawareness in dementia patients. Their results were interpreted in relation to the methodological differences in terms of type of dementia studied, the protocol adopted to measure lack of awareness, the imaging techniques employed, the experimental designs and statistical analyses performed. Results Eighteen studies undertaken to explore the functional and structural correlates of unawareness of cognitive symptoms in dementia were identified. Although t...

2011-01-01

50

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

51

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

52

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular regurgitation was easy to differentiate from pathological paravalvular ...

53

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate ...

2010-10-01

54

Some thoughts on the mechanism of cellular trapping of Cu(II)-ATSM  

British Library Electronic Table of Contents (United Kingdom)

Cu(II)-ATSM continues to be investigated, both in the laboratory and in the clinic, as a tumor hypoxia imaging agent. However, meaningful interpretation of these images requires a more complete understanding of the mechanism by which the tracer is trapped within the cell. Cu(II)-ATSM is a simple molecule and its biochemical interaction with cells is similarly simple, mainly based upon redox chemistry. Here we suggest that the trapping mechanism is biphasic. The first phase is a reduction/oxidation cycle involving thiols and molecular oxygen. This can be followed by interaction with proteins in the mitochondria leading to more permanent retention of the tracer. The uptake mechanism is complicated by this second step because of the changes in the cell resulting from hypoxia, such as an incre...

2010-01-01

55

Polarity of prismatic facets delimiting WC grains in WC-Co alloys  

British Library Electronic Table of Contents (United Kingdom)

This study reports a determination of the polarity of WC facets in WC-Co alloys sintered at the liquid state. In these alloys, WC grains are delimited by basal facets and two sets of {101 0} prismatic facets, one set of facets being much more developed than the other. A variation of the shape is observed as a function of the composition of the alloy. High resolution transmission electron microscopy is used to investigate the polarity of the prismatic facets owing to the typical triangular patterns appearing on the images. The effect of the composition is investigated using two alloys with different carbon potentials and one containing VC and Cr3C2 as grain growth inhibitors. The interpretation of the images shows that in all cases, the same set of prismatic planes is favoured.

2010-01-01

56

Images of addiction and recovery: An interpretative phenomenological analysis of the experience of addiction and recovery as expressed in visual images  

British Library Electronic Table of Contents (United Kingdom)

This article focuses on visual representations of subjective experiences of the process of recovery from addiction and the meanings that participants attribute to their visual work. The data are drawn from a study of six female participants. In this article, we discuss the results with reference to one participant, to allow for detailed consideration of the visual and the verbal material. This participant was selected because of the richness of her material, which provided an opportunity to carry out a detailed case study. Potential participants were informed in advance that they would be asked to draw during the interview. They were also asked to bring to the interview some artwork made during their engagement in creative activities at an earlier stage in their recovery. The data were ana...

2011-01-01

57

Digital atlas of fetal brain MRI  

International Nuclear Information System (INIS)

Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program ...

2010-02-01

58

Improved detection of myocardial infarction with technetium-99m stannous pyrophosphate and serum MB creatine phosphokinase  

International Nuclear Information System (INIS)

The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK activity. Serum MB CPK ...

59

Structural studies of some phospho-borate glasses using ultrasonic pulse-echo technique, DSC and IR spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Glasses in the system (95-x) [0.25 Na{sub 2}O-0.75 B{sub 2}O{sub 3}]-x P{sub 2}O{sub 5}-5 Fe{sub 2}O{sub 3} (0<=x<=15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P{sub 2}O{sub 5} on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P{sub 2}O{sub 5}. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P{sub 2}O{sub 5} content as a second network former. These results are interpreted in terms ...

2009-06-01

60

Elastic properties and structural studies on some zinc-borate glasses derived from ultrasonic, FT-IR and X-ray techniques  

Energy Technology Data Exchange (ETDEWEB)

Glasses in the system (1 - x) [29Na{sub 2}O- 4Al{sub 2}O{sub 3}- 67B{sub 2}O{sub 3}]- xZnO (0 {<=} x {<=} 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N{sub 4} values (fraction of tetrahedral coordinated boron atoms), and substitution of longer ...

2009-05-05

61

THE INTERPRETATION OF ELECTRON MICROSCOPE ...  

Science.gov (United States)

... Accession Number : AD0633770. Title : THE INTERPRETATION OF ELECTRON MICROSCOPE FRACTOGRAPHS. Descriptive Note : Final rept.,. ...

1966-01-21

62

Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy  

International Nuclear Information System (INIS)

The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is ...

2009-10-12

63

Physical Modelling of Axisymmetric Turbulent Impinging Jets as used within the Nuclear Industry for Mobilisation of Sludges  

Energy Technology Data Exchange (ETDEWEB)

The impingement of a fluid jet onto a surface has broad applications across many industries. Within the UK nuclear industry, during the final stages of fuel reprocessing, impinging fluid jets are utilised to mobilise settled sludge material within storage tanks and ponds in preparation for transfer and ultimate immobilisation through vitrification. Despite the extensive applications of impinging jets within the nuclear and other industries, the study of two-phase, solid loaded, impinging jets is limited, and generally restricted to computational modelling. Surprisingly, very little fundamental understanding of the turbulence structure within such fluid flows through experimental investigation is found within the literature. The physical modelling of impinging jet systems could successfully serve to aid computer model validation, determine operating requirements, evaluate plant throughput requirements, optimise process operations and support design. Within this project a method is ...

2008-07-01

64

Pixel-based and object-oriented change detection analysis using high-resolution imagery  

Energy Technology Data Exchange (ETDEWEB)

The high spatial resolution of state-of-the-art commercial satellite imagery provides a good basis for recognising and monitoring even small-scale structural changes within nuclear facilities and for planning of routine and/or challenge inspections of nuclear sites. Despite the advantages of the improved spatial resolution some problems exist that may make the interpretation of the changes more difficult: Firstly, the results of the change analysis can be very complex and unclear at a glance. Secondly, shadow formation and off-nadir images due to different sensor and solar conditions at the acquisition times can cause false signals or overlap real changes. In view to the fast-growing amount of data from different sensor types there are then some requirements of an effective change detection procedure for safeguards purposes: i. The techniques involved should possess a certain amount of robustness in terms of small misregistration errors, ...

2003-05-01

65

Prestin and high frequency hearing in mammals  

UK PubMed Central (United Kingdom)

Recent evidence indicates that the evolution of ultrasonic hearing in echolocating bats and cetaceans has involved adaptive amino acid replacements in the cochlear gene prestin. A substantial...Full Text Available

2011-03-01

66

Intravesical Prostatic Protrusion in Men in Olmsted County, Minnesota  

UK PubMed Central (United Kingdom)

PurposeUltrasonically measured intravesical prostatic protrusion may be a promising noninvasive method of assessing bladder outlet obstruction. Previous investigations...Full Text Available

2009-12-01

67

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)

2002-03-01

68

Automated NDT for large diameter tubular products  

International Nuclear Information System (INIS)

Ultrasonic and eddy-current techniques are used to automatically examine large diameter tubular products during their production for defective areas and out-of-tolerance conditions.

1976-09-06

69

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure ...

2005-08-15

70

Assessment of vesical-ureteral reflux in transplant patients using radionuclide cystography; Exploration scintigraphique des reflux vesico-renaux chez les patients transplantes renaux  

Energy Technology Data Exchange (ETDEWEB)

Direct radionuclide cystography is known to be sensitive and safe in children with suspected vesical-ureteral reflux. In this study we have investigated the utility of direct radionuclide cystography in renal transplant recipients with a recent history of pyelonephritis or recurrent urinary infections. Direct radionuclide cystography is a simple test, however it requires a rigorous methodology in order to obtain images during fill-in as well as during voiding in both men and women. The images must be interpreted using a rigorous image display methodology. Twenty-eight radionuclide cystographies were performed in 17 patients. Among the 17 tests performed for the initial diagnosis of reflux , 12 were positive. Four patients with positive results and four patients with negative results were also investigated by radiologic cystography. Similar results were obtained in those patients. Nine scintigraphies ...

1995-12-31

71

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR ...

1993-12-31

72

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. ...

1982-10-01

73

Technology for enhancing chest auscultation in clinical simulation.  

Science.gov (United States)

The ability to use an acoustic stethoscope to detect lung and/or heart sounds, and then to then communicate one's interpretation of those sounds is an essential skill for many medical professionals. Interpretation of lung and heart sounds, in the context of history and other examination findings, often aids the differential diagnosis. Bedside assessment of changing auscultation findings may also guide treatment. Learning lung and heart auscultation skills typically involves listening to pre-recorded normal and adventitious sounds, often followed by laboratory instruction to guide stethoscope placement, and finally correlating the sounds with the associated pathophysiology and pathology. Recently, medical simulation has become an important tool for teaching prior to clinical practice, and for evaluating bedside auscultation skills. When simulating cardiovascular or pulmonary problems, high-quality lung and heart sounds should be able to ...

2011-02-11

74

Stress measurement and bolt tensioning by ultrasonic methods  

International Nuclear Information System (INIS)

In the past decade, a new technique has been developed for measuring tensile stresses in solids. This ultrasonic technique has been used thus far primarily for measuring fastener tension. The precision of measurement is routinely to 2-3% and, with special care, to approx. 1%. The method is insensitive to the frictional losses which plague tensioning by torque wrench. Though the approach is relatively new, it promises a wide range of applicability.

1980-01-01

75

Multiphase origin of the Cu-Co ore deposits in the western part of the Lufilian fold-and-thrust belt, Katanga (Democratic Republic of Congo)  

British Library Electronic Table of Contents (United Kingdom)

A multiphase origin of the Cu-Co ores in the western part of the Lufilian fold-and-thrust belt in Central Africa is proposed based on literature, satellite image interpretations and petrographic and fluid inclusion analyses on samples from the stratiform mineralization of Kamoto and Musonoi (DR Congo). The various mineral occurrences in the Katanga Copperbelt can be classified in distinct categories: stratiform, supergene enrichment and vein-type. The stratiform mineralization form the largest group and can be found mainly in Lower Roan (R-2) rocks, which can be identified as ridges on satellite imagery. Ore deposits outside the R-2 occur along lineaments and result often from supergene enrichment.The main phase of the stratiform mineralization in the Katanga Copperbelt occurred during dia...

2006-01-01

76

Language and Music in the Musician Brain  

British Library Electronic Table of Contents (United Kingdom)

Abstract Results of numerous experiments conducted over the past 15-years by using behavioural as well as brain imaging methods have shown that musical expertise influences brain anatomy, brain functions and behaviour. The musician- brain is thus considered as a very good model of brain plasticity. Moreover, many results have demonstrated that musical expertise not only impacts on music processing but also on several aspects of speech processing including lexical pitch, sentence intonation and the metric structure of words. Conversely, recent results indicated that linguistic expertise with tone or quantity languages such as Mandarin Chinese, Thai, Finnish and Japanese, influences the processing of harmonic tones and musical intervals. We discuss possible interpretations of these findings ...

2011-01-01

77

Landscape pattern MACRS analysis and the optimal utilization of Shiyang River Basin based on RS and GIS approach  

British Library Electronic Table of Contents (United Kingdom)

Chose the arid interior district Shiyang River basin four issues of Landsat/TM images from 1986 to 2006 to visually interpret, and analyze the natural succession of ecological environment and the landscape pattern characteristic under the human activity interference. The results showed that in past 20years, the number of landscape patch has increased, but the average patch size was decreasing, which explained that the landscape fragmentation degree was increasing, the landscape integrity was declining. The edge density of landscape remained invariable basically, which explained its stability maintained good. The diversity and evenness index continually enhanced, the diversity increased from 0.73 in 1986 to 0.84 in 2006. The mean core patch area of study area reduced from134.47hm2 in 1994 t...

2009-01-01

78

Proceedings of clinical SPECT [single photon emission computed tomography] symposium  

International Nuclear Information System (INIS)

It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have ...

1986-09-22

79

Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy  

International Nuclear Information System (INIS)

This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of ...

1999-02-01

80

Pre-transitional disk nature of the AB Aur disk  

CERN Document Server

The disk around AB Aur was imaged and resolved at 24.6\\,$\\mu$m using the Cooled Mid-Infrared Camera and Spectrometer on the 8.2m Subaru Telescope. The gaussian full-width at half-maximum of the source size is estimated to be 90 $\\pm$ 6 AU, indicating that the disk extends further out at 24.6\\,$\\mu$m than at shorter wavelengths. In order to interpret the extended 24.6\\,$\\mu$m image, we consider a disk with a reduced surface density within a boundary radius $R_c$, which is motivated by radio observations that suggest a reduced inner region within about 100 AU from the star. Introducing the surface density reduction factor $f_c$ for the inner disk, we determine that the best match with the observed radial intensity profile at 24.6\\,$\\mu$m is achieved with $R_c$=88 AU and $f_c$=0.01. We suggest that the extended emission at 24.6\\,$\\mu$m is due to the enhanced emission from a wall-like structure at the boundary radius ...

2010-01-01

81

Microstructural characterization of Ti-6Al-4V metal chips by focused ion beam (FIB) and transmission electron microscopy (TEM)  

Energy Technology Data Exchange (ETDEWEB)

The microstructure of the secondary deformation zone (SDZ) near the cutting surface in metal chips of Ti-6Al-4V formed during machining was investigated using focused ion beam (FIB) specimen preparation and transmission electron microscopy (TEM) imaging. Use of the FIB allowed precise extraction of the specimen across this region to reveal its inhomogeneous microstructure resulting from the non-uniform distribution of strain, strain rate, and temperature generated during the cutting process. Initial imaging from conventional TEM foil preparation revealed microstructures ranging from heavily textured to regions of fine grains. Using FIB preparation, the transverse microstructure could be interpreted as fine grains near the cutting surface which transitioned to coarse grains toward the free surface. At the cutting surface a 10 nm thick recrystallized layer was observed capping a 20 nm thick amorphous layer.

2011-01-01

82

High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A  

CERN Document Server

Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which ...

2009-01-01

83

Fusion of information from optical, thermal, multispectral imagery and geologic/topographic products to detect underground detonations (video). Audio-Visual (Final)  

Energy Technology Data Exchange (ETDEWEB)

The video documents the results of a Small Business Innovative Research (SBIR-Phase II) project conducted for DARPA focusing on the use of all-source overhead remote sensor imagery for monitoring underground nuclear tests and related activities. The documentation includes: (1) the main unclassified body of the report; (2) a separate ground truth Annex; and (3) a separate classified Annex. Autometric's approach was to investigate the exploitation potential of the various sensors, especially the fusion of products from them in combination with each other and other available collateral data. This approach featured empirical analyses of multisensor/multispectral imagery and collateral data collected before, during, and after an actual underground nuclear test (named 'BEXAR'). Advanced softcopy digital image processing and hardcopy image interpretation techniques were investigated for the research. ...

1992-04-01

84

Elastic modeling and steep dips: unraveling the reflected wavefield  

Energy Technology Data Exchange (ETDEWEB)

As part of a larger elastic numerical modeling project, we have been investigating how energy reflected from steeply dipping interfaces is recorded using typical multicomponent acquisition geometries. Specifically, we have been interpreting how rcflection events from the flanks of salt dome structures are distributed on 3C and 4C phones for vertical seismic profiles (VSPs) and ocean bottom seismic (OBS) or land surface surveys. The ultimate goal of this investigation is to improve the structural imaging of steeply dipping interfaces and eventually to evaluate the usc of the recorded elastic wavefield for fluid description near these interfaces. In the current work, we focus on a common assumption used when processing converted wave reflection seismic data that most PP energy is recorded on the vertical geophone and/or the hydrophone and that most PS energy is recorded on the horizontal geophones. This is a useful assumption when it is valid, ...

2003-01-01

85

The Application of Spatial Signature Analysis to Electrical Test Data: Validation Study  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of the Spatial Signature Analysis (SSA) Electrical-test (e-test) validation study that was conducted between February and June, 1998. SSA is an automated procedure developed by researchers at the Oak Ridge National Laboratory to address the issue of intelligent data reduction while providing feedback on current manufacturing processes. SSA was initially developed to automate the analysis of optical defect data. Optical defects can form groups, or clusters, which may have a distinct shape. These patterns can reveal information about the manufacturing process. Optical defect SSA uses image processing algorithms and a classifier system to interpret and identify these patterns, or signatures. SSA has been extended to analyze and interpret electrical test data. The algorithms used for optical defect SSA have been adapted and applied to e-test binmaps. An image of the binmap is ...

1999-03-15

86

Rapid yield learning through optical defect and electrical test analysis  

Energy Technology Data Exchange (ETDEWEB)

As semiconductor device density and wafer area continue to increase, the volume of in-line and off-line data required to diagnose yield-limiting conditions is growing exponentially. To manage this data in the future, analysis tools will be required that can automatically reduce this data to useful information, e.g., by assisting the engineer in rapid root-cause diagnosis of defect generating mechanisms. In this paper, the authors describe a technology known as Spatial Signature Analysis (SSA) and its application to both optically-detected defect data as well as electrical test (e-test) bin data. The results of a validation study are summarized that demonstrate the effectiveness of the SSA approach on optical defect wafermaps through field-testing at three semiconductor manufacturing sites on ASIC, DRAM and SRAM products. This method has been extended to analyze and interpret electrical test data and to provide a pathway for correlation of this data with in-line ...

1998-02-01

88

Ultrasonic Acoustic Emissions from the Sapwood of Thuja occidentalis Measured inside a Pressure Bomb 1  

UK PubMed Central (United Kingdom)

An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available

1984-04-01

89

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

90

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for ...

2009-07-01

91

Results of UT training for defect detection and sizing technique using specimens with fatigue crack and SCC  

International Nuclear Information System (INIS)

At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)

2005-04-01

92

BURST STRENGTH AND NON-DESTRUCTIVE EVALUTION OF COMPOSITE PIPES AND PIPE COUPLINGS WITH DEFECTS (TOP 48)  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...

1996-01-31

93

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

94

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow ...

1995-07-01

95

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow regime, void ...

1346-01-01

96

Multitemporal analysis of satellite data and their use in the monitoring of the environmental impacts of open cast lignite mining areas in Eastern Germany  

Energy Technology Data Exchange (ETDEWEB)

The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas were classified into different spectral ...

1998-08-01

97

Groundwater penetrating radar and high resolution seismic for locating shallow faults in unconsolidated sediments  

Energy Technology Data Exchange (ETDEWEB)

Faults in shallow, unconsolidated sediments, particularly in coastal plain settings, are very difficult to discern during subsurface exploration yet have critical impact to groundwater flow, contaminant transport and geotechnical evaluations. This paper presents a case study using cross-over geophysical technologies in an area where shallow faulting is probable and known contamination exists. A comparison is made between Wenner and dipole-dipole resistivity data, ground penetrating radar, and high resolution seismic data. Data from these methods were verified with a cone penetrometer investigation for subsurface lithology and compared to existing monitoring well data. Interpretations from these techniques are compared with actual and theoretical shallow faulting found in the literature. The results of this study suggests that (1) the CPT study, combined with the monitoring well data may suggest that discontinuities in correlatable zones may indicate that faulting ...

1993-12-31

98

Demonstration of realtime radiography on pipeline girth welds: Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...

1988-09-01

99

Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography  

International Nuclear Information System (INIS)

Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to ...

2009-01-01

100

Acoustic and visual remote sensing of barrels of radioactive waste: Application of civilian and military technology to environmental management of the oceans  

Energy Technology Data Exchange (ETDEWEB)

As part of an ongoing strategic research project to find barrels of radioactive waste off San Francisco, the U.S. Navy (USN), the U.S. Geological Survey (USGS), and the Gulf of the Farallones National Marine Sanctuary (GFNMS) pooled their expertise, resources, and technology to form a partnership to verify new computer enhancement techniques developed for detecting targets the size of 55 gallon barrels on sidescan sonar images. Between 1946 and 1970, approximately 47,800 large barrels and other containers of radioactive waste were dumped in the ocean west of San Francisco; the containers litter an area of the sea floor of at least 1400 km {sup 2} knows as the Farallon Island Radioactive Waste Dump. The exact location of the containers and the potential hazard the containers pose to the environment is unknown. The USGS developed computer techniques and contracted with private industry to enhance sidescan data, collected in cooperation with the GFNMS, to detect ...

1995-04-01

101

Petrophysical Analysis and Geographic Information System for San Juan Basin Tight Gas Reservoirs  

Energy Technology Data Exchange (ETDEWEB)

The primary goal of this project is to increase the availability and ease of access to critical data on the Mesaverde and Dakota tight gas reservoirs of the San Juan Basin. Secondary goals include tuning well log interpretations through integration of core, water chemistry and production analysis data to help identify bypassed pay zones; increased knowledge of permeability ratios and how they affect well drainage and thus infill drilling plans; improved time-depth correlations through regional mapping of sonic logs; and improved understanding of the variability of formation waters within the basin through spatial analysis of water chemistry data. The project will collect, integrate, and analyze a variety of petrophysical and well data concerning the Mesaverde and Dakota reservoirs of the San Juan Basin, with particular emphasis on data available in the areas defined as tight gas areas for purpose of FERC. A relational, geo-referenced database (a geographic ...

2008-10-01

102

Utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humans  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement in the accuracy of /sup 99m/Tc-TBI stress ...

1986-10-01

103

The role of crystallographic and geometrical relationships between #alpha# and #beta# phases in an #alpha#/#beta# titanium alloy  

International Nuclear Information System (INIS)

The present study has examined for #alpha#/#beta#-Ti alloys the relationship between the morphology and crystallography of Widmanstaetten plates of #alpha#-Ti in colonies within a prior grain of #beta#-Ti. Thus, optical metallography, scanning electron microscopy and transmission electron microscopy have been used to characterize the morphological features of the microstructure, whereas orientation-imaging microscopy (OM) and transmission electron microscopy (TEM) have been employed to reveal crystallographic information. It has been discovered that within a prior #beta#-Ti grain, although the growth direction of the Widmanstaetten plates in given colonies may differ by large angles from #alpha#-plates in other colonies, they may exhibit very close crystallographic relationships. For example, inclined #alpha#-plates may share common basal planes and be related by a rotation of #approx#10.5 deg. about the c-axis of the crystals. This phenomenon has been ...

2003-09-15

104

Noise bias in the refinement of structures derived from single particles  

Energy Technology Data Exchange (ETDEWEB)

One of the main goals in the determination of three-dimensional macromolecular structures from electron microscope images of individual molecules and complexes (single particles) is a sufficiently high spatial resolution, about 4 A, at which the interpretation with an atomic model becomes possible. To reach high resolution, an iterative refinement procedure using an expectation maximization algorithm is often used that leads to a more accurate alignment of the positional and orientational parameters for each particle. We show here the results of refinement algorithms that use a phase residual, a linear correlation coefficient, or a weighted correlation coefficient to align individual particles. The algorithms were applied to computer-generated data sets that contained projections from model structures, as well as noise. The algorithms show different degrees of over-fitting, especially at high resolution where the signal is weak. We demonstrate ...

2004-12-15

105

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple ...

1993-07-01

106

Effects of morpho dynamics in shallow waters over pipeline facilities; Efeitos da morfodinamica em aguas rasas sobre instalacoes de dutos  

Energy Technology Data Exchange (ETDEWEB)

The success in developing of the oil industry operating in offshore-onshore terminals, connected by pipelines with the facilities of the coastal zone, can be attributed partially to the beach morpho dynamic monitoring. This study represents a solution to the concerns of the technical operations in coastal zones because it minimizes the impact of the petroleum production and it assures the environmental protection associated to the risks of the pipelines breaking. This impact type results mainly of the vertical and horizontal displacements of the beach, from the coastal dunes to the shore face. The mobility of the profile is associated to the magnitude of the sedimentary processes, which reproduce naturally or not, in scale of time that can vary among few days, years or decades. For the monitoring and interpretation of the beach profile mobility the following methods are recommended: calculation of the closure depth with base in the wave data; bathymetric survey ...

2003-07-01

107

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

108

A two-arm gaseous spiral in the inner 200 pc of the early-type galaxy NGC 2974: signature of an inner bar  

CERN Document Server

TIGER integral-field spectrography and HST/WFPC2 imaging of the E3 galaxy NGC 2974 are used to derive the kinematics of the stellar and ionized gas components in its central 500 pc. We derive a numerical two-integral distribution function from a MGE mass model using the HQ formalism. The TIGER as well as published long-slit stellar kinematics are well fitted with this self-consistent model, requiring neither the addition of a significant mass contribution from a hidden disc structure, nor the presence of a central dark mass. The data reveal the presence of a striking, highly contrasted, two-arm gaseous spiral structure within a radius of ~200 pc, corresponding to a total mass of 6.8x10^4 Msun of ionized gas. We use a deconvolved TIGER datacube to probe its kinematics at a resolution of about 0.35 arcsec. Strong departures from circular motions are observed, as well as high velocity dispersion values on the inner side of the arms. We interpret ...

2003-01-01

109

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the ...

2005-01-01

110

4D experience on Girassol Field block 17, Angola  

Energy Technology Data Exchange (ETDEWEB)

The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding on the location of latest development ...

2004-07-01

111

Nonphotochemical Hole-Burning Imaging Studies of in vitro Carcinoma and Normal Cells Utilizing a Mitochondrial Specific Dye  

Energy Technology Data Exchange (ETDEWEB)

Low temperature Nonphotochemical Hole Burning (NPHB) Spectroscopy of the dye rhodamine 800 (MF680) was applied for the purpose of discerning differences between cultured normal and carcinoma ovarian surface epithelial (OSE) cells. Both the cell lines were developed and characterized at the Mayo Clinic (Rochester, MN), with the normal cell line having been transfected with a strain of temperature sensitive Simian Virus 40 Large T Antigen (SV40) for the purpose of extending the life of the cell culture without inducing permanent changes in the characteristics of the cell line. The cationic lipophilic fluorophore rhodamine 800 preferentially locates in in situ mitochondria due to the high lipid composition of mitochondria and the generation of a large negative membrane potential (relative to the cellular cytoplasm) for oxidative phosphorylation. Results presented for NPHB of MF680 located in the cells show significant differences between the two cell lines. The results are ...

2002-06-27

112

Nonphotochemical Hole-Burning Imaging Studies of In Vitro Carcinoma and Normal Cells Utilizing a Mitochondrial Specific Dye  

Energy Technology Data Exchange (ETDEWEB)

Low temperature Nonphotochemical Hole Burning (NPHB) Spectroscopy of the dye rhodamine 800 (MF680) was applied for the purpose of discerning differences between cultured normal and carcinoma ovarian surface epithelial (OSE) cells. Both the cell lines were developed and characterized at the Mayo Clinic (Rochester, MN), with the normal cell line having been transfected with a strain of temperature sensitive Simian Virus 40 Large T Antigen (SV40) for the purpose of extending the life of the cell culture without inducing permanent changes in the characteristics of the cell line. The cationic lipophilic fluorophore rhodamine 800 preferentially locates in in situ mitochondria due to the high lipid composition of mitochondria and the generation of a large negative membrane potential (relative to the cellular cytoplasm) for oxidative phosphorylation. Results presented for NPHB of MF680 located in the cells show significant differences between the two cell lines. The results are ...

2002-08-01

113

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

114

Physical interpretation of recent isomer investigations  

International Nuclear Information System (INIS)

... lifetime lutetium isotopes lutetium 171 lutetium 173 lutetium 175 lutetium 177

1975-08-01

115
116

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

117

Ultrasonic Phased Array Implementation of the Inside Diameter Creeping Wave Sizing Method  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a technique for implementing the ultrasonic inside diameter (ID) creeping wave technique for detection and sizing ID connected defects using a phased array ultrasonic system. The technique uses multiple focal laws to produce the examination modes. The first focal law is designed to create a shear wave nominally at the critical angle for mode conversion to a longitudinal wave at the ID of a part, thus creating a creeping wave. This focal law is focused at the ID to improve sensitivity. The rest of the laws are designed to create tandem sound paths that progress up a vertical surface directly above the focal point of the creeping wave generation point. When a defect on the inner surface is detected with the creeping wave, the height of the defect can be measured from the response of a set of tandem laws without readjusting the position of the probe. Results from standard one-inch long notches of varying depths are presented.

2006-05-01

118

Development of a rapid extraction procedure for speciation of arsenic in chicken meat  

Energy Technology Data Exchange (ETDEWEB)

A rapid extraction procedure has been developed for speciation of arsenic in chicken tissue. Water, methanol-water (1:1), and methanol-chloroform (1:1) were tested as extraction media. Individual use of an ultrasonic bath, a microwave oven, or an ultrasonic probe was not sufficient for quantitative recovery of As(III), dimethylarsinate, monomethylarsonate, As(V), and arsenobetaine in spiked samples of chicken tissue. A new extraction procedure using a methanol-water mixture and a microwave oven then an ultrasonic probe enabled extraction of the arsenic species in 7 min with efficiencies ranging from 80 to 100%. HPLC-UV-HG-AFS was used for the determinations. The extraction procedure was 100% efficient when applied to real samples of chicken tissue. AsB (48{+-}5 {mu}g As kg {sup -1}) and one containing-arsenic feed additive, Nitarsone (227{+-}5 {mu}g As kg {sup -1}) were detected. (orig.)

2006-08-15

119

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill inspection and manipulation requirements were developed for the inspection of the 30 welds ...

1994-12-31

120

An investigation of homogeneous and heterogeneous sonochemistry for the destruction of hazardous substances. Progress report, 1996--1997  

Energy Technology Data Exchange (ETDEWEB)

'The primary objective of this research project is to acquire a deeper fundamental knowledge of acoustic cavitation and cavitation chemistry, and in doing so, to ascertain how ultrasonic irradiation can be more effectively applied to environmental problems. Four on-going projects will be described in this progress report, The first project is the destruction of carbofuran in a Near-Field Acoustical Processor (NAP), and the hydrodynamic characterization of the reactor. The second project is a comprehensive study of how ultrasonic frequency influences sonochemical reaction rates; the substrate it, the preliminary portion of this study has been hydrogen peroxide formation. The third project in progress is destruction of four polychlorinated biphenyls at 20 kHz. Work so far has been at 20 kHz, but the most significant portion of this project will involve a multi-frequency (ultrasonic frequency) study. Finally, the ...

1997-01-01

121

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)

2009-07-20

122

Quantitative non-destructive evaluation of high-temperature superconducting materials  

Energy Technology Data Exchange (ETDEWEB)

Even though the currently intensive research efforts on high- temperature superconducting materials have not yet converged on a well specified practical material, the indications are that such a material may be quite brittle, anisotropic, and may contain many flaws such as microcracks and voids at grain boundaries. Consequently, practical applications of high temperature superconducting materials will require a very careful strength analysis based on fracture mechanics considerations. Because of the high sensitivity of the strength of such materials to the presence of defects, methods of quantitative non-destructive evaluation may be expected to play an important role in strength determinations. This proposal is concerned with the use of ultrasonic methods to detect and characterize isolated cracks, clusters of microcracks and microcracks distributed throughout the material. Particular attention has been, and will continue to be devoted to relating ...

1991-06-14

123

New NDT developments for the control of components in the FA3 EPR nuclear reactor at Flamanville; Nouveau developpement END pour le controle de composants de la tranche EPR de Flamanville (FA3)  

Energy Technology Data Exchange (ETDEWEB)

New Non Destructive Testing techniques are currently being developed for the inspection of two groups of components in the FA3 EPR nuclear reactor at Flamanville. The first group of components to be controlled is constituted by the welds of the (89) rod cluster control assemblies' containment; two control types are to be used: an ultrasonic technique (UT) evaluation from the outside of the flange-casing weld, and an ET control from the inside of the three other welds. The second group of components is formed by the 44 welded joints of the primary circuit, which will be inspected through ultrasonic testing. Details of the components, control devices and sensors are given and some test results are presented

2009-07-01

124

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory capacities to permit them to cope with in ...

1992-12-31

125

Extraction of biologic particles by pumping effect in a p-shaped ultrasonic actuator  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a new method of extracting biologic particles from a mixture of particles. The method is based on the pumping effect in a p-shaped ultrasonic actuator, which has a gap between its two vibrating metal plates. An adhesive tape is placed at a proper position in the gap. Due to the pumping effect which is induced by the sound field in the gap, the particles with smaller mass and radius in the mixture can be pumped up to reach the adhesive tape; while the ones with larger mass cannot. Therefore, the particles with smaller mass and radius can be extracted from the mixture. A theoretical model which can well explain the operation principle and experimental phenomena is developed. By the experimental results and the theoretical analyses based on the model, the validity of the m...

2006-01-01

126

Comparison of interface evolution of ultrasonic aluminum and gold wire wedge bonds during thermal aging  

British Library Electronic Table of Contents (United Kingdom)

Ultrasonic gold and aluminum wire wedge bonding are widely used for electrical and signal interconnections of the integrated circuit chip packages. In this paper, based on the metallurgical theories and thermal aging test methods, the long-term thermal reliabilities of gold and aluminum wire wedge bonding on aluminum and Au/Ni/Cu pads, were investigated, respectively. At 200degreeC, the Au/Al bond interfaces evolved little when the storage time was less than 48h; with the aging time increasing, the interfacial intermetallic compounds (IMC) grew up from the pad (vertical growth); the primary compounds were Au5Al2 near the bond toe and heel, and Au2Al at the periphery. Then, the thickness of IMC was unchanged, and extended horizontally (lateral growth), Au5Al2 transformed into more stable Au...

2007-01-01

127

Automatic phased array ultrasonic testing of pressure vessels; Automatisierte Mehrkanal Ultraschallpruefung von Druckgasbehaeltern  

Energy Technology Data Exchange (ETDEWEB)

Automatic ultrasonic testing is presented as a method for recurrent inspections of pressure gas vessels, from validation to practical testing to customised test applications. National and international regulations and standards are presented along with related implementation problems. [German] Es wird die automatisierte Ultraschallpruefung im Bereich der wiederkehrenden Pruefung von Druckgasbehaeltern, als Alternative zur herkoemmlichen, klassischen Wasserdruckpruefung, vorgestellt. Von der Validierung ueber die praktische Erprobung bis hin zur kundenspezifisch entwickelten Pruefapplikation. Es werden die Anforderungen aus nationalen und internationalen Vorschriften und Normen sowie die damit zusammenhaengenden Umsetzungsprobleme behandelt.

2005-07-01

128

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ...

1997-12-01

129

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated cortical volumes showed ...

2000-01-01

130

Dexamethasone-suppression adrenal scintigraphy in hyperandrogenism: concise communication  

Energy Technology Data Exchange (ETDEWEB)

To assess the contribution of adrenal-derived androgens in women with hirsutism, adrenal scintigrams under dexamethasone suppression (DS) were performed on 35 women with increasing facial or body hair and irregular or absent menses. Based upon the DS regimen chosen (8 mg/d for 2 days or 4 md/d for 7 days before the injection of 6..beta..-(/sup 131/I)iodomethylnorcholesterol), three imaging patterns were identified. The first was the absence of uptake before 3 days (8-mg DS) or before 5 days (4-mg DS) after injection. This imaging pattern was seen in 17 of the 35 patients studied and was considered normal. The second pattern was bilateral uptake earlier than 3 days (8-mg DS regimen) or 5 days (4-mg DS) after injection. This was seen in 13 of the 35 patients and was interpreted as bilateral early visualization. Adrenal-vein catheterization performed on six patients with this pattern showed increased adrenal-vein testosterone. ...

1981-01-01

131

An analysis strategy for safeguards use of optical satellite imagery  

International Nuclear Information System (INIS)

This paper outlines conceptual framework for safeguards remote sensing, and suggests a strategy for overcoming the challenges to full exploitation of all types of optical satellite imagery. Since the introduction of commercial open-source high-resolution satellite imagery in 1999, it has become an important tool for verification of declarations, baseline mapping, detection and monitoring of changes and investigation of undeclared activities. Its use is still relatively restricted, but there is a growing demand for wider satellite reconnaissance support, and the Satellite Image Analysis Unit (SIAU) has recently been expanded in response. For a number of reasons, IAEA safeguards use of satellite imagery is largely based on visual interpretation by experienced image analysts of high-resolution monochromatic imagery to monitor and characterize buildings and structures on safeguards sites. The very wide range of remote sensing ...

2006-10-16

134

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

135

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

136

Radiations against tumors: a bit old-fashioned?; Rayonnements contre tumeurs: un rien demode?  

Energy Technology Data Exchange (ETDEWEB)

The proton therapy gives an irradiation adapted to the shape and the depth of tumors ( eyes, head and neck) with a millimetric, even sub millimetric precision for the ophthalmological tumors. It is equally an excellent tool for the pediatrics tumors. For numerous treatments in France the proton therapy is associated to the photons treatments (x radiation). however, others physical treatments could modulate the medical offer, such thermal therapy or treatments by ultrasonic waves. (N.C.)

2004-09-01

137

Phonon relaxation and internal friction in heterogeneous systems based on poly(vinyl chloride)  

British Library Electronic Table of Contents (United Kingdom)

Phonon relaxation and internal friction in kaolin-and bentonite-filled PVC composites are studied. By varying the temperature and/or content of the ultrafine mineral filler in the PVC, one can control the contribution from phonon viscosity, damping force, and the effect of viscosity into the energy dissipation of ultrasonic oscillations in the MHz frequency interval. The dynamic character of the measurements makes it possible to differentiate between relaxation phenomena in the composites and to suggest methods for their controlled changes.

2010-01-01

138

Domestic and industrial applications of microwaves; Les micro-ondes dans les applications domestiques et/ou industrielles  

Energy Technology Data Exchange (ETDEWEB)

In addition to their use in high-speed ovens, microwaves are also finding applications in industrial manufacture, quality control and storage - anywhere where the high-frequency transmission or reflection properties of a material can be exploited. Microwaves are also being used in medical applications for the characterization of certain type of tumours. They are also being used in research into ultrasonic cavitation. (authors) 5 refs.

1999-01-01

139

Development of techniques for joining of high-sensitivity solar cells. Final report; Entwicklung von Verbindungstechniken fuer hoch empfindliche Solarzellen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The report investigates a number of joining techniques, i.e. isothermal solidification, ultrasonic welding, thermocompression, and glueing. (HW) [Deutsch] In diesem Vorhaben wurden verschiedene Verbindungstechniken untersucht: Isotherme Erstarrung; Ultraschall-Schweissen; Thermokompression; Leitkleben. (HW)

1992-09-01

140

An ultrasonic goniometer for surface stress measurement  

Science.gov (United States)

An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.

1978-09-01

141

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

143

Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 13. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results obtained during Stage 13 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A brief proposal for the continuation of this program in Stage 14 is also given at the end of the report. The program executed in Stage 13 consists of three parts and the work performed in each part is summarized below. 1. Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR). Although the original goal of the investigations of the MSR in Stage 13 was to calculate the neutron noise induced by the fluctuations of the fuel temperature, the study, solution and interpretation of the static problem, as well as to define an approximate version of the point kinetic approximation was necessary to perform. As it turned out, these tasks in themselves were more involved, and also very edifying, to solve. Hence, in this report, we confine the study of ...

2008-06-15

144

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

145

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

146

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

147

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

148

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

149

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

150

The application of 64 multidetector CT angiography in the evaluation of carotid stenosis and follow-up of carotid endarterectomy and percutaneous transluminal stenting  

International Nuclear Information System (INIS)

Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the ...

2006-09-01

151

Quantitative bone scintigraphy. A study in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a decrease to the pre-operative level after two ...

1985-06-02

152

Model for predicting the effects of laser exposures and eye protection on vision. Interim report, January 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser safety standards and eye protection (filters) are designed to limit ocular exposures to prevent retinal lesions, yet eyesafe laser exposures can disrupt vision by causing glare and flashblindness. Protective filters can have opposing effects on vision function. They reduce laser exposures but also reduce task luminance and contrast. Filters alone may interfere with vision and consequently reduce work safety and performance. It is therefore important to be able to predict the effects of both laser exposures and protective filters to assess trade-offs between protection and visual function. This paper briefly reviews the methods, concepts, and experimental database used in our laboratory to predict laser, filter, and laser-plus-filter effects on tasks involving visual detection. The modeling approach uses estimates of the spatial distribution of light in the retinal image of the laser source to predict glare, flashblindness, and retinal lesions. It also ...

1990-01-01

153

MRI of normal fetal brain development  

International Nuclear Information System (INIS)

Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a symmetrical or asymmetrical environment, leading ...

2006-02-01

154

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, subjects breathed a 5% CO(2) gas mixture. Under ...

2004-01-01

155

Hydrogen embrittlement, revisited by in situ electrochemical nanoindentation  

Energy Technology Data Exchange (ETDEWEB)

The fine scale mechanical probing capability of NI-AFM was used to examine hydrogen interaction with plasticity. To realize this, an electrochemical three electrode setup was incorporated into the NI-AFM. The developed ECNI-AFM is capable of performing nanoindentation as well as imaging surfaces inside electrolytes. The developed ECNI-AFM setup was used to examine the effect of cathodically charged hydrogen on dislocation nucleation in pure metals and alloys. It was shown that hydrogen reduces the pop-in load in all of the tested materials except Cu. The reduced pop-in load can be interpreted as the HELP mechanism. Classical dislocation theory was used to model the homogeneous dislocation nucleation and it was shown that H reduces the activation energy for dislocation nucleation in H sensitive metals which are not undergoing a phase transformation. The activation energy for dislocation nucleation is related to the material specific parameters; ...

2007-07-01

156

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils.  

Energy Technology Data Exchange (ETDEWEB)

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, high-precision ...

2005-11-04

157

Development of methodics for the characterization of the composition of the ion-collision-induced secondary-particle flux by comparison of the yield contributions of photoinduced ion formation processes; Entwicklung einer Methodik zur Charakterisierung der Zusammensetzung des ionenbeschussinduzierten Sekundaerteilchenflusses durch Vergleich der Ausbeuteanteile photoinduzierter Ionenbildungsprozesse  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to develop a method to distinguish between different ion formation processes and to determine the influence of these processes on the total number of detected monatomic ions of a certain element. A vector/matrix-formalism was developed, which describes the physical processes of sputtering, ion formation, mass separation and detection in laser-SNMS. In the framework of the method developed, based on this theoretic formalism, changes in the secondary flux contribution of the respective element were observed by comparing the detected monatomic ion yield obtained in specifically aligned (SIMS and) laser-SNMS experiments. The yields resulting from these experiments were used to calculate characteristic numbers to compare the flux composition from different surfaces. The potential of the method was demonstrated for the elements boron, iron and gadolinium by investigating the changes in the flux composition of secondary particles sputtered from metallic surfaces, as a ...

2008-10-13

158
160

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

161
168

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

169

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

177

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

178

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

179

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

180

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

181

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

182

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

183

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

184

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

185

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

186

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

187

Time-of-Flight Measurements from Eddy Current Tests  

Science.gov (United States)

Data fusion techniques are based on the premise that two or more carefully designed NDE tests are potentially capable of offering additional information concerning the test object relative to what can be garnered from a single test. However, information from a heterogeneous set of transducers cannot be fused unless the data is mapped onto a common `format'. The eddy current method cannot, for example, provide time-of-flight information that can be combined from estimates derived from ultrasonic tests. This paper presents a simple solution to address the problem by employing the so-called Q-transform to relate diffusive fields, such as those generated by eddy current probes, and propagating wave fields generated by ultrasonic NDT sensors. The paper illustrates how the distance between a defect and a source can be extracted from eddy current data generated using carefully selected excitation signals. Numerical results and comparisons with ...

2003-03-01

188

Synthesis and characterization of Al{sub 2}O{sub 3}/ZrO{sub 2}, Al{sub 2}O{sub 3}/TiO{sub 2} and Al{sub 2}O{sub 3}/ZrO{sub 2}/TiO{sub 2} ceramic composite particles prepared by ultrasonic spray pyrolysis  

Energy Technology Data Exchange (ETDEWEB)

Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.

2002-08-01

189

Synthesis and characterization of Al_2O_3/ZrO_2, Al_2O_3/TiO_2 and Al_2O_3/ZrO_2/TiO_2 ceramic composite particles prepared by ultrasonic spray pyrolysis  

International Nuclear Information System (INIS)

Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.

2002-08-01

190

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet customers' ...

1999-12-01

191

Porous tooling process for manufacture of graphite/polyimide composites. Final report  

Energy Technology Data Exchange (ETDEWEB)

A porous tooling system was selected for the processing of Graphite/PMR-15 Polyimide laminates in thickness up to 3.2 mm. (0.125 inch). This tool system must have a reasonable strength, permeability dimensional stability, and thermal conductivity to accomplish curing at 600 F and 200 psi and 200 psi autoclave temperature and pressure. A permeability measuring apparatus was constructed and permeability vs. casting water level determined to produce tools at three different permeability levels. On these tools, laminates of 5, 11, and 22 plies (.027, .060, and 0.121 inch) were produced and evaluated by ultrasonic, mechanical, and thermal tests to determine the effect of the tool permeability on the cured laminates. All tools produced acceptable laminates at 5 and 11 plies but only the highest permeability produced acceptable clear ultrasonic C-Scans. Recommendations are made for future investigations of design geometry, and strengthening techniques ...

1981-01-01

192

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...

1995-08-01

193

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

194

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the detectability of these probes. (author).

1991-08-01

195

Advanced direct liquefaction concepts for PETC generic units. Quarterly report, October 1991--December 1991  

Science.gov (United States)

A laser pyrolysis technique has been used to produce ultrafine particles of iron carbide with diameters ranging from 2 to 20 nm. Catalysis using iron carbide was investigated in the liquefaction of Wyodak subbituminous coal; yields were determined. A study was carried out to examine the possibility of using an ultrasonic extraction technique as a rapid method of product work-up of samples following pretreatment or liquefaction experiments. A similar study had shown that extraction of coal-derived products by an ultrasonic method was rapid and gave yields and product distributions comparable to those obtained by Soxhlet extraction. On another project, three different types of supported catalysts were used to test activity for the combined water-gas shift hydrogenation of a synthetic donor solvent. The three catalysts tested were: (1) Alumina supported NiMo catalyst-Shell 324m; (2) Bulk hydrous TiO NiMo catalyst; (3) Thin film hydrous TiO ...

1991-12-31

196

Nondestructive Technique Survey for Assessing Integrity of Composite Firing Vessel  

Energy Technology Data Exchange (ETDEWEB)

The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.

2000-08-01

197

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

198

Decontamination of Johnston Island Coral: a preliminary study  

International Nuclear Information System (INIS)

A preliminary investigation was completed on the characterization and decontamination of coral samples from Johnston Island. These samples were found to contain individual particles (2 to 0.25 mm) of contaminated coral as well as a piece of contaminated magnetic metal. They ranged in activity from about 70 to 811 nCi Am-241. The decontamination methods investigated were froth flotation, ferrite treatment, attrition scrubbing, ultrasonic treatment and dry sieving. Dry sieving, the more effective technique, separated about 42 wt % of the coral into a decontaminated fraction. This fraction (>4 mm) contained about 0.5% of the total activity. 7 refs., 3 tabs.

199

Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983  

Science.gov (United States)

During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.

1984-10-01

200

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

201

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

202

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

203

Automatic interpretation of Schlumberger soundings  

Energy Technology Data Exchange (ETDEWEB)

The automatic interpretation of apparent resistivity curves from horizontally layered earth models is carried out by the curve-fitting method in three steps: (1) the observed VES data are interpolated at equidistant points of electrode separations on the logarithmic scale by using the cubic spline function, (2) the layer parameters which are resistivities and depths are predicted from the sampled apparent resistivity values by SALS system program and (3) the theoretical VES curves from the models are calculated by Ghosh's linear filter method using the Zhody's computer program. Two soundings taken over Takenoyu geothermal area were chosen to test the procedures of the automatic interpretation.

1980-09-01

204

The interpretation of systematic reviews with meta-analyses: an objective or subjective process?  

UK PubMed Central (United Kingdom)

BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available

205

The Product Operator Formalism: A Physical and Graphical Interpretation  

UK PubMed Central (United Kingdom)

The product-operator formalism is the most commonly used tool for describing and designing multidimensional NMR experiments. In spite of its relative simplicity and sound theoretical underpinnings,...Full Text Available

2010-03-01

206

Tachyons and theory of quasi-catastrophes  

International Nuclear Information System (INIS)

The author discusses the formulation and application of the theory of quasi-catastrophes for the behaviour and properties of tachyons. This approach assists in the interpretation of experiments where tachyons may be involved. (W.D.L.).

207

Tachyons and the causal paradox  

International Nuclear Information System (INIS)

The author attempts to clear up the causal 'paradox' often associated with the existence of tacyons. This leads to a discussion of the nature of tachyon messages and the problems involved in their interpretation. (W.D.L.).

208

SS 433 as a black hole candidate  

Energy Technology Data Exchange (ETDEWEB)

The inverse problem of interpreting the SS 433 optical light curves is solved for a geometrically thick model accretion disk around the compact relativistic object: most likely a black hole.

1985-01-01

209

Quantum probabilities: an information-theoretic interpretation  

CERN Document Server

This Chapter develops a realist information-theoretic interpretation of the nonclassical features of quantum probabilities. On this view, what is fundamental in the transition from classical to quantum physics is the recognition that \\emph{information in the physical sense has new structural features}, just as the transition from classical to relativistic physics rests on the recognition that space-time is structurally different than we thought. Hilbert space, the event space of quantum systems, is interpreted as a kinematic (i.e., pre-dynamic) framework for an indeterministic physics, in the sense that the geometric structure of Hilbert space imposes objective probabilistic or information-theoretic constraints on correlations between events, just as the geometric structure of Minkowski space in special relativity imposes spatio-temporal kinematic constraints on events. The interpretation of quantum probabilities is more ...

2010-01-01

210

Nucleon Form Factor Measurements and Interpretation  

Energy Technology Data Exchange (ETDEWEB)

The data base for the form factors of the nucleon obtained from elastic ep scattering is discussed, as well as some recent developments in their calculation.

2007-08-22

211

Newton's first law and the existence of free tachyons  

International Nuclear Information System (INIS)

NEWTON's first law prohibits the coupling of free tachyons to ordinary matter, if it is interpreted as selection rule interdicting emission without change of the rest-mass of the emitting system.

213

INTERPRETATION OF RADAR DATA FROM THE ICY GALILEAN SATELLITES AND ...  

Science.gov (United States)

(1989], however, we modeled the phase using a sum of simple power law terms. We. chose to do our work on Triton's atmosphere using the exponential functions ...

214

Deep Space Probe Science Experiment  

Science.gov (United States)

Briefly, 48 MOS microparticle sensors (essentially the same as those flown on .... at the Naval Research Lab to interpret the polarization of the incoming radio .... Adapter Satellite, to be published in Journal of Spacecraft and Rockets, 1994. ...

215

Considering uncertainties in the reservoir interpretation of geophysical data. Application to segmentation; Prise en compte des incertitudes dans l'interpretation reservoir des donnees geophysiques. Application a la segmentation  

Energy Technology Data Exchange (ETDEWEB)

Qualitative interpretation of data of different nature and sources, based on segmentation techniques such as discriminant analysis, is useful to characterize and monitor hydrocarbon reservoirs. In order to make this interpretation more reliable, it is necessary to characterize uncertainties attached to data and then, to propagate them in the interpretation work-flow. In this thesis, uncertainties are represented by intervals, because usually, little is known about input data errors. The uncertainty characterization issue is dealt with specifically for each case study. The uncertainty propagation issue is treated by a new technique, based on interval analysis, which consists in extending to intervals various popular approaches (non parametric, quadratic and linear) to discriminant analysis: Firstly, a learning phase allows calibrating an imprecise classifying model on the basis of pre-interpreted data. ...

2001-10-01

216

Artificial and natural duplicates in pyrosequencing reads of metagenomic data  

UK PubMed Central (United Kingdom)

BackgroundArtificial duplicates from pyrosequencing reads may lead to incorrect interpretation of the abundance of species and genes in metagenomic studies. Duplicated reads were...Full Text Available

217

A Caution Against Interpreting and Quantifying Oyster Habitat Loss from Historical Surveys  

Science.gov (United States)

... surveys, and increasing interest in both developing an oyster aquaculture industry and scaling up restoration efforts by federal, ... ...

218

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

219

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

220

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

221

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

222

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

223

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

224

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

225

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

226

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

227

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

228

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

229

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

230

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

231

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

232

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

233

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

234

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

235

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

236

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

237

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

238

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

239

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

240

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

241

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

242

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

243

Unified interpretation for second-order subwavelength interference based on Feynman's path-integral theory  

International Nuclear Information System (INIS)

The second-order spatial subwavelength interference pattern is observed in a modified Michelson interferometer with single-mode continuous-wave laser beams. By analyzing our subwavelength interference experiment based on Feynman's path integral theory, a unified interpretation for all the second-order subwavelength interference is suggested.

2010-07-01

244

A phenomenological interpretation of trace impurity transport  

Energy Technology Data Exchange (ETDEWEB)

An interpretive theory of trace impurity transport in tokamaks is presented. It is based on an earlier phenomenological approach developed by the authors for describing tokamak plasma transport experiments. The present model is used to explain disparate phenomena observed in ALCATOR C and DITE in a unified phenomenological framework. Predictive numerical calculations are presented for DITE conditions. If experimentally confirmed, the model could be used to correlate plasma properties with trace impurity behaviour. (orig.)

1989-10-01

245

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

246

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

247

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

248

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

249

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

250

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

251

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

252

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

253

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

254

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

255

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

256

Nitrogen doping into titanium dioxide by the sol?gel method using nitric acid  

British Library Electronic Table of Contents (United Kingdom)

N-doped TiO2 has been prepared by use of sol?gel systems containing titanium alkoxide, with nitric acid as the nitrogen source. The time needed for gelation of the systems was drastically reduced by ultrasonic irradiation. The peaks assigned to the nitrate and nitrous ions were observed by FT-IR measurement during the sol?gel reaction. The N-doping was confirmed by the observation of N?O peaks in the XPS spectrum of the sample heated at 400??C. The nitrate ion acted as an oxidizer of the ethanol solvent and titanium species. The TiO2 became doped with nitrogen oxide species as a result of reduction of nitrate ion incorporated into the dried gel samples. These results indicated that the added nitric acid was reduced during the sol?gel transition and heating process, and the resulting NO spe...

2011-01-01

257

Manufacture and first wall joining for an ITER primary wall module prototype: R and D phase with small scale mock-ups  

International Nuclear Information System (INIS)

In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.

2001-10-01

258

Inspection procedure and essential parameters in NDT qualification; Tarkastusohje ja olennaiset muuttujat NDT-paetevoeinnissae  

Energy Technology Data Exchange (ETDEWEB)

The objective of the inspection qualification is to ensure that applied non-destructive methods (NDT) have the required performance. The approach of the qualification process is systematic and carefully documented and therefore some new requirements can be seen concerning the composition of the documentation. There are also new document types, that only application of the inspection qualification requires. The most important of these is the technical justification, that includes the documented evidences concerning the performance of the inspection system. This publication includes two reports: 'Compilation of the inspection procedure' and 'Essential/influential parameters in NDT qualification'. The former of these discusses the issues to be considered in an inspection procedure especially from the point of view of the mechanised ultrasonic testing. The later report explains the parameters formulated to analyse in the technical ...

2000-06-01

259

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI disorders.

2009-05-15

260

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

261

Electrochemical characterization of MnO2 as the cathode material for a high voltage hybrid capacitor  

British Library Electronic Table of Contents (United Kingdom)

Manganese dioxide (MnO2) was prepared using the ultrasonic method. Its electrochemical performance was evaluated as the cathode material for a high voltage hybrid capacitor. And the specific capacitance of the MnO2 electrode reached 240 F.g-1. The new hybrid capacitor was constructed, combining Al/Al2O3 as the anode and MnO2 as the cathode with electrolyte for the aluminum electrolytic capacitor to solve the problem of low working voltage of a supercapacitor unit. The results showed that the hybrid capacitor had a high energy density and the ability of quick charging and discharging according to the electrochemical performance test. The capacitance was 84.4 mF, and the volume and mass energy densities were greatly improved compared to those of the traditional aluminum electrolytic capacito...

2009-01-01

262

Elastic properties, hardness and indentation fracture toughness of #beta#-sialons  

International Nuclear Information System (INIS)

Dense samples of #beta#-sialons (with z from 1 to 4) were pressuressly sintered for different time (15-240 minutes) and at relatively low temperature of 1600 C using single-phase #beta#-sialon powders synthesized by combustion nitridation. The samples were characterized using ultrasonic method for determination of elastic properties (E,G,#mu#). Also, hardness by Knoop and fracture toughness by Vickers indentation microfracture method was estimated. With increasing z number Young's modulus decreases from 293 to 179 GPa. Simultaneously Poisson ratio increases by about 30%. The highest values of hardness and fracture toughness were obtained for sialon with z equal to 1. (orig.).

1993-10-04

263

Dimensional stability, optical and elastic properties of MgAl{sub 2}O{sub 4} spinel irradiated in FFTF to very high exposures  

Energy Technology Data Exchange (ETDEWEB)

Stoichiometric MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA at temperatures between 385 and 750C to fluences ranging from 2.2 to 24.9 {times} 10{sup 22}n cm{sup {minus}2} (E>0.1 MeV) darken significantly, but do not develop any significant loss in weight or change in dimensions. Similar behavior was observed in both single crystal and fully dense polycrystalline specimens. Measurements of elastic constants by an ultrasonic technique show that no measurable changes occur as a result of the irradiation. These and other results confirm the stability of this material for fusion application as an electrical insulator.

1993-10-01

264

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

265

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

266

Chemical and morphological characterization of mesoporous material supported copper oxide nanoparticles for potential application  

British Library Electronic Table of Contents (United Kingdom)

SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...

2011-01-01

267

Behavior of trace refractory minerals in the lithium metaborate fusion-acid dissolution procedure  

Science.gov (United States)

The feasibility of this procedure was investigated using minerals and ore specimens. The substances were ground then fused using LiBO/sub 2/, quenched with 3% HNO/sub 3/ or mixtures of the acid with 2.5% tartaric acid or 30% H/sub 2/O/sub 2/. The quenched melt was usually completely dissolved within 20 min by placing the beakers in an ultrasonic bath. If any residue was detected, appropriate changes were made in the procedure. Once the procedure has been optimized, any remaining black particles were filtered. If these particles disappeared upon subsequent ignition, they were presumed to have been graphite. Most of the refractory minerals investigated should be expected to be converted to soluble form by this process. 1 table.

1983-12-01

268

Automation techniques for fully automated coil transport; Kanzen jido koiru hanso wo jitsugen shita jidoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Kawasaki Steel started the construction of an automatic steel strip coil transportation system in the 1980's. Presently, most of the in-plant transportation of hot-rolled or cold-rolled coils are automated. For establishing the automatic transportation, there were developed various technologies, such as, the optimum handling technology using artificial intelligence, the technology of preventing additional piling of coils on existing coils by using an ultrasonic wave and a laser beam. Through the improvements of these technologies, a full-automated transportation system has been achieved and the system has contributed substantially toward product quality assurance and cost reduction. This paper gives the changes in the automation technology of coil transportation in the automation of No. 3 finishing hot rolling mill, now having the latest automatic system, in Chiba Works. (author)

1999-12-01

269

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

270

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

271

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...

2001-01-01

272

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

273

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...

274

Incidence of lesions as described by MRI in focal epilepsy of frontal and temporal onset; Inzidenz kernspintomographisch erfassbarer Laesionen bei der Abklaerung fokaler Epilepsien frontalen und temporalen Ursprunges  

Energy Technology Data Exchange (ETDEWEB)

Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis (T2w-images), ...

1997-09-01

275

Visible Earth: Typhoon Aere  

Science.gov (United States)

NASA's Visible Earth catalog of NASA images and animations of our home planet.

278

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

282

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

287

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

289

Lead-203 for skeletal imaging  

International Nuclear Information System (INIS)

... biological variability body distribution kidneys labelled compounds lead 203

290

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

292

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

300

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

315

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

317

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

318

Utilization of fractional Brownian motion in constrained least-squares restoration of medical images  

International Nuclear Information System (INIS)

Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.

319

Document image retrieval with morphology-based segmentation and features combination  

Science.gov (United States)

Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...

2011-01-01

320

Comparative evaluation of /sup 99m/Tc GH, /sup 99m/TcO_4, and /sup 99m/Tc DTPA as brain imaging agents  

International Nuclear Information System (INIS)

The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.

321

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

322

Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia  

International Nuclear Information System (INIS)

Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.

323

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other ...

2004-07-01

324

In-situ examination of turbine components (blade roots, rotor steeple grooves and disk-blade rim attachments) of low-pressure steam turbine, using phased array technology  

Energy Technology Data Exchange (ETDEWEB)

A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data analysis was done in near-real time. ...

2000-07-01

325

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl chloride tube becomes ...

1997-05-27

326

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...

1982-06-01

327

Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' performed by SKB ...

2005-12-15

328

Using and Interpreting Adjusted NNT Measures in Biomedical Research  

UK PubMed Central (United Kingdom)

The number needed to treat (NNT) is a popular effect measure to present study results in biomedical research. NNTs were originally proposed to describe the absolute effect of a new treatment compared...Full Text Available

329

The phase space of tachyons  

International Nuclear Information System (INIS)

The phase space of quantized systems that contain tachyons has been investigated. Interpretation difficulties and unexpected divergences are found when it is considered the volume of Lorentz-invariant phase space. These problems can be overcome, however, at the expense of Lorentz invariance.

330

Statistical treatment of the inner M-shell excitation in heavy ion-atom collisions  

Energy Technology Data Exchange (ETDEWEB)

A statistical treatment has been applied to interpret the experimental data on the Xe M-shell vacancy production in slow 1.05 MeV Xe-Xe collisions and is shown to give better agreement with experiment than that of the molecular-orbital models.

1983-06-27

331

Spontaneous Cortical Activity Reveals Hallmarks of an Optimal Internal Model of the Environment *  

UK PubMed Central (United Kingdom)

The brain maintains internal models of its environment to interpret sensory inputs and prepare actions. While behavioral studies demonstrated that these internal models are optimally adapted...Full Text Available

2011-01-07

332

Spatial analysis of BSE cases in the Netherlands  

UK PubMed Central (United Kingdom)

BackgroundIn many of the European countries affected by Bovine Spongiform Encephalopathy (BSE), case clustering patterns have been observed. Most of these patterns have been interpreted...Full Text Available

333

Sonic hedgehog controls growth of external genitalia by regulating cell cycle kinetics  

UK PubMed Central (United Kingdom)

During embryonic development, cells are instructed which position to occupy, they interpret these cues as differentiation programmes, and expand these patterns by growth. Sonic hedgehog...Full Text Available

2010-06-01

334

Reanalyses of Gulf of Mexico fisheries data: Landings can be misleading in assessments of fisheries and fisheries ecosystems  

UK PubMed Central (United Kingdom)

We used two high profile articles as cases to demonstrate that use of fishery landings data can lead to faulty interpretations about the condition of fishery ecosystems. One case uses the mean trophic...Full Text Available

2008-02-19

335

Quantum group structure in the unitary minimal model  

Energy Technology Data Exchange (ETDEWEB)

We obtain a symmetry algebra for any unitary minimal model by using the representation of conformal field theories. This symmetry algebra can be interpreted as a quantum group. The generalization to non-unitary minimal models is direct. (orig.).

1989-10-05

336

Quantum group structure in the unitary minimal model  

International Nuclear Information System (INIS)

We obtain a symmetry algebra for any unitary minimal model by using the representation of conformal field theories. This symmetry algebra can be interpreted as a quantum group. The generalization to non-unitary minimal models is direct. (orig.).

337

Procedures and interpretation of oxygen diffusion and burn up trials in the laboratory and in situ; Procedures et interpretation des essais de diffusion et de consommation d'oxygene en laboratoire et in situ  

Energy Technology Data Exchange (ETDEWEB)

The development of soil cover with capillary effect required laboratory experiments where diffusion was studied. The effective diffusion coefficients D of materials in the different layers were determined, as well as the reaction constants of reactive materials. Once soil cover is in place, its efficiency can be controlled by oxygen burn up trials in situ. In the specific case where the materials that comprise the soil cover consume oxygen, even in small quantities, the usual interpretation of these trials is not applicable. In this poster presentation, the authors proposed different procedures for long term trials, in situ and in the laboratory, as well as a new interpretation method based on the use of numerical solutions to the modified Fick equations of diffusion for reactive materials. Special emphasis is placed on the proper enunciation of the laws and the solutions appropriate in such situations. The authors illustrated the procedure ...

2000-07-01

338

Precise temporal control of the eye regulatory gene Pax6 via enhancer-binding site affinity  

UK PubMed Central (United Kingdom)

How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available

2010-05-15

339

Planning and interpreting cement bond logs; Implementation of an expert system  

Energy Technology Data Exchange (ETDEWEB)

The Cement Bond Log Advisor is an expert system being developed to assist users in the design, evaluation, and interpretation of cement bond logs (CBL's). CBL's are produced by sonic tools run after the casing is cemented in a well to determine how well the cement is bonded to the casing and formation and whether a cement squeeze jog should be attempted. During the development of program, two particular challenges were encountered and resolved in ways that might be of general interest to developers of expert system applications for the petroleum industry. The first challenge was to find an efficient and effective method for guiding the user in correlating and interpreting the relationships between multiple sources of continuous visual data (the various waveforms making up the log output). Second, the nomographs, which correlate log amplitudes with cement compressive strength and are used in the log ...

1991-07-01

340

Phase space of tachyons  

Energy Technology Data Exchange (ETDEWEB)

The phase space of quantized systems that contain tachyons has been investigated. Interpretation difficulties and unexpected divergences are found when we consider the volume of Lorentz-invariant phase space. These problems can be overcome, however, at the expense of Lorentz invariance.

1983-12-21

341

Particle creation if a cosmic string snaps  

CERN Document Server

We calculate the Bogolubov coefficients for a metric which describes the snapping of a cosmic string. If we insist on a matching condition for all times {\\it and} a particle interpretation, we find no particle creation.

1994-01-01

342

Localizing potentially active post-transcriptional regulations in the Ewing's sarcoma gene regulatory network  

UK PubMed Central (United Kingdom)

BackgroundA wide range of techniques is now available for analyzing regulatory networks. Nonetheless, most of these techniques fail to interpret large-scale transcriptional data...Full Text Available

343

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

344

Glossary of Commercial and Trade Law Terms (Komerclikumu Un Tirdzniecibas Terminu Vardnica) English/Latvian - Latvian/English.  

Science.gov (United States)

The definitions provided in this bilingual glossary are intended to serve as indicative explanations of the defined words and phrases, and not for purposes of interpreting any particular contract or international agreement. Approximately 100 terms appear ...

1995-01-01

345

Glossary of Commercial and Trade Law Terms (Kaubandus-ja Ariseaduse Oskussonastik). English/Estonian - Estonian/English.  

Science.gov (United States)

The definitions provided in this bilingual glossary are intended to serve as indicative explanations of the defined words and phrases and not for purposes of interpreting any particular contract or international agreement. Approximately 100 terms appear w...

1995-01-01

346

Glossary of Commercial and Trade Law Terms (Glosar de Termeni de Drept Comercial). English/Romanian - Romanian/English.  

Science.gov (United States)

The definitions provided in this bilingual glossary are intended to serve as indicative explanations of the defined words and phrases, and not for purposes of interpreting any particular contract or international agreement. Approximately 100 terms appear ...

1995-01-01

347

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

348

From Classical Genetics to Quantitative Genetics to Systems Biology: Modeling Epistasis  

UK PubMed Central (United Kingdom)

Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available

2008-03-01

349

Free electron laser  

International Nuclear Information System (INIS)

Physics and technology of free electron laser (FEL) are reviewed. Mechanisms of stimulated emission in FEL and its present status and future prospects are presented. Electromagnetic wiggler, two stage FEL and so on are also interpreted. Finally, accelerators and wigglers for FEL, recent FEL experiments and FEL applications are noted. (author).

350

Energy-momentum tensor of a spinor field in the mixed universe cosmological model  

International Nuclear Information System (INIS)

The energy-momentum tensor of a massless spinor field is constructed and studied based on the previously proposed interpretation of quantum effects of such a field in the anisotropic metric of Bianchi type IX. The characteristic properties of the energy-momentum tensor in the mixed universe model are discussed.

351

Does the socioeconomic context explain both mortality and income inequality? Prospective register-based study of Norwegian regions  

UK PubMed Central (United Kingdom)

BackgroundStudies from various countries have observed worse population health in geographical areas with more income inequality. The psychosocial interpretation of this association...Full Text Available

352

Chaotic system of two-phase flow in a small, horizontal, rectangular channel.  

Science.gov (United States)

Various measurement tools that are used in chaos theory were applied to analyze two-phase pressure signals with the objective of identifying and interpreting flow pattern transitions for two-phase flows in a small, horizontal rectangular channel. These me...

1995-01-01

353

A plausible model for reversal of neoplastic transformations in plants based on multiple steady states.  

UK PubMed Central (United Kingdom)

We offer a plausible interpretation of some experiments on the reversal of neoplastic transformations in plants. We suggest that normal cells and tumorous cells represent multiple stable-steady states...Full Text Available

1991-12-01

354

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...

2003-01-01

355

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

356

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

357

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...

1985-01-01

358

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...

1993-12-01

359

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

360

Nonrelativistic reduction and interpretation of the Klein-Gordon equation of tachyons  

International Nuclear Information System (INIS)

A one-dimensional tachyon Klein-Gordon equation is reduced to a nonrelativistic-tachyon equation of motion. The interpretation of this reduced equation leads to the following conclusions: 1) tachyons can be localized in time instead of in space as compared with bradyons, 2) space representation and momentum representation of bradyonic quantum equation of motion are replaced by time representation and energy representation in tachyon quantum equation of motion and 3) with the aid of these results, it has been found that the solutions of the tachyon Klein-Gordon equation of motion form a complete set. (author).

361

MACROSCOPIC ONTOLOGY IN EVERETTIAN QUANTUM MECHANICS  

British Library Electronic Table of Contents (United Kingdom)

Abstract Simon Saunders and David Wallace have proposed an attractive semantics for interpreting linguistic communities embedded in an Everettian multiverse. It provides a charitable interpretation of our ordinary talk about the future, and allows us to retain a principle of bivalence for propositions and to retain the law of excluded middle in the logic of propositions about the future. But difficulties arise when it comes to providing an appropriate account of the metaphysics of macroscopic objects and events. I evaluate various metaphysical frameworks which might be combined with the Saunders-Wallace semantics. I conclude that the most appropriate metaphysics to underwrite the semantics renders Everettian quantum mechanics a theory of non-overlapping worlds.

2011-01-01

362

Focus and the exclusion of alternatives: On the interaction of syntactic structure with pragmatic inference  

British Library Electronic Table of Contents (United Kingdom)

The claim that focus evokes a set of alternatives is a central issue in several accounts of the effects of focus on interpretation. This article presents two empirical studies that examine whether this property of focus is independent of contextual conditions. The syntactic operation at issue is object-fronting in German, Spanish, Greek, and Hungarian licensed by contexts involving focus on the object constituent. This operation evokes the intuition that the fronted referent excludes some or all relevant alternatives. The presented experiments deal with the question whether this interpretative property obligatorily accompanies the operation at issue or not. The empirical findings show that in German, Spanish, and Greek this intuition depends on properties of the context and is sensitive to...

2011-01-01

363

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

364

Tracheal images using energy subtraction Fuji computed radiography  

International Nuclear Information System (INIS)

Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).

1985-01-01

365

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

366

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

367

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

368

Parallel architecture for rapid image generation and analysis  

Energy Technology Data Exchange (ETDEWEB)

A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...

1987-01-01

369

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

370

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

371

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

372

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

373

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...

2007-08-21

374

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...

2007-08-21

375

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...

1991-12-01

376

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...

1991-01-01

377

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-08-01

378

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-01-01

379

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

380

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...

1989-08-01

381

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...

1989-01-01

382

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

383

Volume 2- Technical Approach - IMAGE Science Center - NASA  

Science.gov (United States)

Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...

384

Verification of MLC based real-time tumor tracking using an electronic portal imaging device  

UK PubMed Central (United Kingdom)

Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available

2010-06-01

385

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...

2007-07-01

386

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

387

Subject-specific, multiscale simulation of electrophysiology: a software pipeline for image-based models and application examples  

UK PubMed Central (United Kingdom)

Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available

2009-06-13

388

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

389

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

Energy Technology Data Exchange (ETDEWEB)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-03-01

390

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

International Nuclear Information System (INIS)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-01-01

391

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

392

Signal and imaging sciences workshop proceedings  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

1997-11-01

393

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

394

Romantic and Sexual Relationships, Body Image, and Fertility in Adolescent and Young Adult Testicular Cancer Survivors: A Review of the Literature  

UK PubMed Central (United Kingdom)

This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available

2010-08-01

395

Retinal Fundus Image Registration via Vascular Structure Graph Matching  

UK PubMed Central (United Kingdom)

Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available

2010-01-01

396

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

397

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

398

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

399

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

400

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...

2008-04-15

401

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

402

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

403

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

404

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

405

JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases  

UK PubMed Central (United Kingdom)

BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available

406

In vivo imaging of neutrotransmitter functions in brain, heart and tumors  

Energy Technology Data Exchange (ETDEWEB)

This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.

1991-01-01

407

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

408

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

409

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

410

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

411

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

412

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

413

Dual-channel imaging system for singlet oxygen and photosensitizer for PDT  

UK PubMed Central (United Kingdom)

A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available

414

Doppler imaging using spectrally-encoded endoscopy  

UK PubMed Central (United Kingdom)

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available

2008-09-15

415

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-09-01

416

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-01-01

417

Design and Implementation of an Open Source Indexing Solution for a Large Set of Radiological Reports and Images  

UK PubMed Central (United Kingdom)

This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available

2007-11-01

418

Correspondence of Ultrasound Elasticity Imaging to Direct Mechanical Measurement in Aging DVT in Rats  

UK PubMed Central (United Kingdom)

Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available

2005-10-01

419

Closing the loop in cortically-coupled computer vision: a brain-computer interface for searching image databases.  

Science.gov (United States)

We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...

2011-05-12

420

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

421

Challenges of functional imaging research of pain in children  

UK PubMed Central (United Kingdom)

Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available

422

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

423

Antisense imaging of gene expression in the brain in vivo  

UK PubMed Central (United Kingdom)

Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available

2000-12-19

424

A high-speed network for cardiac image review.  

UK PubMed Central (United Kingdom)

A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available

1994-01-01

425

A comparison with result of normalized image to different template image on statistical parametric mapping of ADHD children patients  

Energy Technology Data Exchange (ETDEWEB)

We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

2003-06-15

426

A Software System for Data Analysis in Automated DNA?Sequencing  

UK PubMed Central (United Kingdom)

Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available

1998-06-01

427

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

428

metadata, images and captions. - The Gateway to Astronaut ...  

Science.gov (United States)

... the Zaire is not an efficient transportation link because of many rapids and falls to negotiate between Kinshasa and the port city of Matadi. ...

429

Visible Earth: Food Additives  

Science.gov (United States)

Feb 25, 2008 ... NASA's Visible Earth catalog of NASA images and animations of our home planet.

430

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

431

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

432

Three-dimensional image display of brain tumor utilizing a modified voxel method  

Energy Technology Data Exchange (ETDEWEB)

The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.

1988-08-01

435

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

437

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

438

Radioiodine benzodiazepines as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1992-03-17

439

Radioiodine benzodiazepines as brain imaging agents  

International Nuclear Information System (INIS)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1990-06-25

440

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

441

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

444

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

445

Particle-Sizing System for Scanning Electron Microscope ...  

Science.gov (United States)

... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...

1991-03-01

446

Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax)  

International Nuclear Information System (INIS)

Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)

2002-08-01

447

Monitoring the movement of water influx subsidence in coal district by remote sensing - examples from Huainan coal district  

Energy Technology Data Exchange (ETDEWEB)

Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.

2002-08-01

448

MER-DIMES : a planetary landing application of computer vision  

Science.gov (United States)

During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System

2005-01-01

451

Incidental discovery of asplenia syndrome, with situs inversus and a normal heart by radionuclide biliary imaging. A case report  

International Nuclear Information System (INIS)

/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.

452

Improved quadrant anode image sensor with microchannel plates  

Energy Technology Data Exchange (ETDEWEB)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-15

453

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

454

Imaging findings of abdominal peripheral primitive neuroectodermal tumor: report of four cases with pathological correlation  

British Library Electronic Table of Contents (United Kingdom)

Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.

2009-01-01

455

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

456

Image Descriptors for Displays  

Science.gov (United States)

... 44 2. Luminance Power Spectral Density Measurements ..... 44 ... 50 4. Chrominance Power Spectral Density Measurements ..... 53 ...

1977-02-01

457

Iao: The New Adaptive Optics Visible Imaging and ...  

Science.gov (United States)

... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...

2008-09-01

458

Growth, Characterization and Device Development in ...  

Science.gov (United States)

... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...

1998-03-01

460

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

461

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

462

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

463

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

464

DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics  

Science.gov (United States)

... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....

465

Computer vision approaches to medical image analysis. Revised papers  

Energy Technology Data Exchange (ETDEWEB)

This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)

2006-07-01

466

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

467

Burned Timber Canyon  

Science.gov (United States)

The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....

468

An improved quadrant anode image sensor with microchannel plates  

International Nuclear Information System (INIS)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).

1987-11-01

469

An improved quadrant anode image sensor with microchannel plates  

Science.gov (United States)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-01

470

An Integrated Approach to Intelligent Systems  

Science.gov (United States)

... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...

2002-01-01

472

A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber  

Science.gov (United States)

... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...

473

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

474

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

475

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

476

Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery  

International Nuclear Information System (INIS)

Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck ...

1985-06-02

477

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

478

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

479

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

480

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

481

Proceedings: Image Understanding Workshop  

Energy Technology Data Exchange (ETDEWEB)

Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.

1987-01-01

482

Principium research of real-time neutron radiography in No. 300 reactor  

International Nuclear Information System (INIS)

The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper

2002-12-01

483

Point/counterpoint: dose-related issues in cardiac CT imaging  

British Library Electronic Table of Contents (United Kingdom)

This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.

2011-01-01

484

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

485

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

486

Multiple imaging radiography at LNLS  

Energy Technology Data Exchange (ETDEWEB)

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

2008-01-11

487

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

488

Monoclonal antibody imaging in malignant and benign gastrointestinal diseases  

International Nuclear Information System (INIS)

The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).

489

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

490

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

491

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

492

Imaging Three Dimensional Two-Particle Correlations for Heavy-Ion Reaction Studies  

Energy Technology Data Exchange (ETDEWEB)

The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.

2005-06-27

493

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

494

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

495

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

496

Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998  

Energy Technology Data Exchange (ETDEWEB)

Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout that were investigated include bleeding, shrinkage, bond strength, freeze-thaw ...

1998-11-01

497

Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber  

Energy Technology Data Exchange (ETDEWEB)

A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as NO{sub x}. were reduced about 50%. The ...

1997-12-31

498

Propagation of guided waves in aircraft structure  

International Nuclear Information System (INIS)

The potential of ultrasonic guided modes for use in global structural health monitoring of aging metallic aircraft can only be realized if the modes selected are able to propagate over a reasonable distance. This work studies the propagation of different modes through fuselage structure by means of mode analysis, finite element modeling and experimental measurement. Beginning with the case of a simple skin panel, the paper examines propagation across a set of structural features representing a typical monocoque fuselage and considers the effect of overlying sealant layers, bonded and sealed joints, paint layers and tapering skin. With the exception of the fundamental symmetric mode at very low frequency, no mode was found that could propagate across all features with an effective attenuation of less than 40 dB/m. This makes global monitoring of a fuselage structure using a sparse array of transducers very difficult. However, more local monitoring is possible and ...

2000-05-23

499

Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea  

Energy Technology Data Exchange (ETDEWEB)

An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed boundary layer. Both fast- ...

1998-07-01

500

A novel drug and gene co-delivery system based on Poly(epsilon-caprolactone)-Poly(ethylene glycol)-Poly(epsilon-caprolactone) grafted polyethyleneimine micelle.  

Science.gov (United States)

In this paper, we prepared a novel cationic self-assembled micelle from poly(epsilon-caprolactone)-poly(ethyl glycol)-poly(epsilon-caprolactone) grafted polyethyleneimine (PCEC-g-PEI). The PCEC-g-PEI micelles, formed by self-assembly method, had mean particle size of ca. 82 nm and zeta potential of +22.5 mV at 37 degrees C, and could efficiently transfer pGFP into HEK293 cells in vitro. Meanwhile, as a model hydrophobic chemotherapeutic drug, honokiol was loaded into PCEC-g-PEI micelles by direct dissolution method assisted by ultrasonication. The honokiol loaded cationic PCEC-g-PEI micelles could effectively adsorb DNA onto its surface, while it could release honokiol in an extended period in vitro. This study demonstrated a novel DNA and hydrophobic chemotherapeutic drug co-delivery system. PMID:21121283

2010-12-01