Evaluation of the cleanliness of ultrapure water by the analysis for metal concentration deposited on Si wafer surface using vapor phase decomposition/inductively coupled plasma mass spectrometry  

International Nuclear Information System (INIS)

Along with the shrinkage of LSI geometries, a higher quality of ultrapure water has been continuously required. Analytical technology for ultrapure water has also progressed before ultrapure water production technology improvements. In this study, we performed optimization of the analytical conditions for the direct analysis of acid droplets, and established an analytical technology for measurements of trace amounts of metallic impurities deposited on a wafer surface by means of Vapor Phase Decomposition (VPD)/Inductively Coupled Plasma Mass Spectrometry (ICP-MS). As a result, analytical technology for metallic elements of the 1x10"8 atoms/cm"2 level on wafer surface has been established. By applying analytical technology to the wafer that has been contacted with ultrapure water, a new evaluation technology for ...

2010-07-01

2

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

3

EDI as a Treatment Module in Recycling Spent Rinse Waters  

Energy Technology Data Exchange (ETDEWEB)

Recycling of the spent rinse water discharged from the wet benches commonly used in semiconductor processing is one tactic for responding to the targets for water usage published in the 1997 National Technology Roadmap for Semiconductors (NTRS). Not only does the NTRS list a target that dramatically reduces total water usage/unit area of silicon manufactured by the industry in the future but for the years 2003 and beyond, the NTRS actually touts goals which would have semiconductor manufacturers drawing less water from a regional water supply per unit area of silicon manufactured than the quantity of ultrapure water (UPW) used in the production of that same silicon. Achieving this latter NTRS target strongly implies more widespread recycling of spent rinse waters at semiconductor manufacturing sites. In spite of the fact ...

1999-08-11

4

Reducing the costs of ultrapure water production - a case study  

Energy Technology Data Exchange (ETDEWEB)

The 380 MW combined cycle gas turbine power station in Peterborough changed its water supply from town mains to high purity reverse osmosis permeate in October 2000. The high purity water is produced from secondary treated sewage effluent using advanced membrane technology. Alpheus Environmental and British Gas staff have recently completed a study of the power station's demineralization plant to identify the differences in operating costs associated with the change in feedwater. The results show that the ultrapure water produced after the change to a high purity feed is of improved quality and that the demineralization plant regeneration operating costs have been reduced by over 90%. The demineralization plant availability has increased from 78 to 98% enabling almost 20% more ultra pure water to be produced. The change in feedwater has also improved the local environment ...

2002-02-01

5

Direct dark matter identification with a hybrid detection technique  

CERN Document Server

In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.

2008-01-01

6

Creation of nitrogen-vacancy centres in diamond with high resolution  

International Nuclear Information System (INIS)

Nowadays, diamond and the nitrogen-vacancy (NV) colour centres constitute the best solid-state system in view of quantum-computing applications. It has also been shown recently that single NV centres could be used as nanoscale magnetic sensors. Such applications require the creation of single NV centres with very high resolution and with a high efficiency. The nano-implanter at the university of Bochum provides low energy nitrogen ions which can be implanted through a hole pierced in the tip of an atomic force microscope. Ultrapure diamond samples have been implanted with spot sizes of 50nm and less. Stimulated Emission Depletion (STED) microscopy has been used to characterise and resolve the implanted spots.

2010-03-21

7

Anaerobic treatment of wastewater from a food-manufacturing plant with a low concentration of organic matter and regeneration of usable pure water  

Energy Technology Data Exchange (ETDEWEB)

Wastewater from a food-manufacturing plant with a low concentration of organic matter was treated at 37 centigrade in an anaerobic fluidized-bed reactor or in an upflow anaerobic sludge blanket. As the influent TOC (total organic carbon) concentration decreased, the TOC removal efficiency in these reactors decreased from 85% to 65%. The concentration of suspended solids in the effluent could be reduced to 20 mg/l, which corresponded to 7% of that in the influent. The effluent from both reactors was treated aerobically in a fixed-bed reactor. The TOC concentration and optical density of effluent from the aerobic treatment were reduced to 5 mg/l and 0.005, respectively. When the effluent treated anaerobically or aerobically was passed over an activated carbon column, the effluent TOC concentration was reduced to 2 to 3 mg/l. The conductivity in raw wastewater was remarkably reduced on an ion-exchange resin column. Ultra-pure water for industrial ...

1994-03-25

8

Surface morphology of thin lysozyme films produced by matrix-assisted pulsed laser evaporation (MAPLE)  

Energy Technology Data Exchange (ETDEWEB)

Thin films of the protein, lysozyme, have been deposited by the matrix-assisted pulsed laser evaporation (MAPLE) technique. Frozen targets of 0.3-1.0 wt.% lysozyme dissolved in ultrapure water were irradiated by laser light at 355 nm with a fluence of 2 J/cm{sup 2}. The surface quality of the thin lysozyme films of different thickness deposited on 7 mm x 7 mm Si-<1 0 0>-wafers was investigated with scanning electron microscopy and atomic force microscopy. Already at comparatively low thickness, {approx}20 nm, the substrate is covered by intact lysozyme molecules and fragments. The concentration of lysozyme in the ice matrix apparently does not play any significant role for the morphology of the film. The morphology obtained with MAPLE has been compared with results for direct laser irradiation of a pressed lysozyme sample (i.e. pulsed laser deposition (PLD))

2007-12-15

10

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples ...

1995-01-15

11

Water | Editorial Board  

Wastenet

...Tota-MaharajE-Mail: Interests: water and wastewater treatment, environmental engineering and sustainable systems; sustainable water management; sustainable urban drainage systems (SUDS); combined renewable energy applications with reverse osmosis desalination; microbial fuel cells for bioenergy production and treatment of urban wastewater; solar photocatalytic treatment and disinfection of water/wastewater Dr. Simon Toze CSIRO Land and Water, Queensland Bioscience Precinct - St Lucia, 306 Carmody Road, St Lucia QLD 4067,...

12

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

13

Electrical conductivity of pyrolyzed polyacrylonitrile  

Energy Technology Data Exchange (ETDEWEB)

Using ultrapure samples of polyacrylonitrile (PAN) of 485,000 or 150,000 average molecular weight solution cast in dimethylformamide, the dc conductivity (sigma) of pyrolyzed PAN (PANP) films has been studied for pyrolysis temperatures (T/ sub p/) of 280 to 435/sup 0/C. Conductivity measurements made during pyrolysis indicate the onset of a dramatic increase in sigma for T/sub p/ of 390 to 435/sup 0/C. Conductivities as high as 5 (ohm-cm)/sup -1/ have been observed for T/sub p/ < 435/sup 0/C.

1981-01-01

14

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect ...

2005-07-01

15

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

16

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

17

The Behavior of Water in Jet Fuels and the Clogging of ...  

Science.gov (United States)

... values and unless special precautions and equipment are used, it would be very difficult to service and maintain operational jet-fuel systems with ...

1950-01-11

18

Effects of Convective Hydraulic Circulation on Phosphorus ...  

Science.gov (United States)

... For other aquatic systems, detailed diel observations of both water temper- ature and periods of flow will be necessary to estimate convective ...

1993-02-01

19

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

20

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

21

Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system  

British Library Electronic Table of Contents (United Kingdom)

Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

2011-01-01

22

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

23

Major roles of water chemistry for safe and reliable nuclear power plant operation. Research committee on water chemistry standard  

International Nuclear Information System (INIS)

The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)

2007-05-01

24

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

25

Hybrid solution and pump-storage optimization in water supply system efficiency: A case study  

International Nuclear Information System (INIS)

Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to ...

2008-11-01

26

Rapid preparation of pyrogen-free 2H2(18)O for human-nutrition studies  

International Nuclear Information System (INIS)

We describe a compact ultrafiltration system for the removal of pyrogens and bacteria from water labeled with the stable isotopes of deuterium and oxygen-18. The ultrafiltration system is constructed from readily available commercial components and can achieve complete removal of pyrogens and bacteria from 1L contaminated water within 30 min. By use of our procedure, loss of the isotopically labeled water by retention in the filtration system was minimal. The purified water is suitable for both oral and intravenous administration to healthy human subjects participating in nutrition studies.

27

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the ...

1982-12-14

28

The controllability analysis of the purification system for heavy water reactors  

International Nuclear Information System (INIS)

The heavy water reactor such as Wolsung No.1 and No.2 has a purification system to purify the reactor coolant. The control system regulates the coolant temperature to protect the ion exchanger. After the fuel exchanges of operating plant, the increase of the coolant pressure makes the purification temperature control difficult. In this paper, the controllability of the control dynamics of the purification system was analysed and the optimal parameters were proposed. To reduce the effects of the flow disturbance, the feedforward control structure was proposed and analysed.

2001-10-01

29

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

30

Siemens provides treatment packages for oil production  

British Library Electronic Table of Contents (United Kingdom)

Modec International Inc has selected Siemens Water Technologies to provide sea-water reverse osmosis (SWRO) systems for several floating, production, storage and offloading (FPSO) vessels that are to be operated in deep-water locations. Siemens is also supplying a wastewater reuse system to one of Brazils largest refineries.

2010-01-01

31

Corrosion of Cu-W condensates in tap water  

International Nuclear Information System (INIS)

Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.

32

WATER SUPPLY ANALYSIS  

Energy Technology Data Exchange (ETDEWEB)

This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.

1996-02-06

33

Separation of rubidium from irradiated aluminum-encapsulated uranium  

International Nuclear Information System (INIS)

A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.

1993-05-01

34

Separation of rubidium from irradiated aluminum-encapsulated uranium  

Energy Technology Data Exchange (ETDEWEB)

A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.

1982-01-01

35

New High-Pressure Excitations in Parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

Raman and infrared spectroscopy of para-H{sub 2} to pressures in excess of 200GPa and to 8K using new ultrapure synthetic diamond anvils reveals numerous new vibrational excitations in the three high-pressure phases. Highly resolved Raman-active librons indicate differences in orientational ordering between phasesII and III, including evidence for changes within phaseII. The librons in phaseIII are strongly pressure dependent and reflect a substantial increase in ordering with pressure. Multiple vibrons in all three phases (I, II, and III) are observed. The results place new bounds on predicted crystal structures and dynamics of the dense molecular solid. {copyright} {ital 1997} {ital The American Physical Society}

1998-01-01

36

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

37

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

38

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

39

Monitoring of the Water Levels in the Wetlands of Fourmile Branch Near the F- and H-Areas of SRS: FY97  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the piezometer network is to establish baseline hydraulic head data for the water table aquifer at the F- and H-Area seeplines prior to startup of the groundwater extraction/injection remediation system.

1999-06-02

40

Steady-state neutronic investigations to the accident of water ingress in systems with pebble-bed high-temperature gas-cooled reactor fuel  

Energy Technology Data Exchange (ETDEWEB)

For light water reactors, loss of coolant is an important point in safety analysis, whereas for gas-cooled reactors the ingress of water into the core region is an incident of safety relevance. The applicability of the computer code system GAMTEREX to pebble beds of spherical high-temperature gas-cooled reactor fuel elements with simulated water ingress is verified by experiment. The measurements were performed at a Siemens-Argonaut reactor, using its ring core as a driver zone for a pebble-bed core in the center of the reactor.

1987-09-01

41

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

42

Temporal variations of fluoride concentration in Isparta public water system and health impact assessment (SW-Turkey)  

British Library Electronic Table of Contents (United Kingdom)

Water?rock interaction is one of the prime factors affecting the fluoride contents of surface and groundwater. If fluoride concentration of drinking water has been neglected, excess fluoride can cause serious dental and medical problems on human health, which is well known at Golcuk-Isparta region. In the research area, Egirdir lake, Golcuk lake and surrounding springs have been utilized as drinking water sources. Golcuk lake water and surrounding groundwaters have high fluoride content (1.4?4.6?mg/l), which is above the WHO standards. Fluoride is predominantly supplied by dissolution of fluoride within the fluormicas of volcanics during the circulation of water. Fluoride concentrations of waters have shown variations for dry and rainy seasons depending on the degree of interaction between...

2008-01-01

43

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

44

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the ...

2000-05-01

45

Flue gas desulfurization wastewater treatment primer  

Science.gov (United States)

Purge water from a typical wet flue gas desulfurization system contains myriad chemical constituents and heavy metals whose mixture is determined by the fuel source and combustion products as well as the stack gas treatment process. A well-designed water treatment system can tolerate upstream fuel and sorbent arranged in just the right order to produce wastewater acceptable for discharge. This article presents state-of-the-art technologies for treating the waste water that is generated by wet FGD systems. 11 figs., 3 tabs.

2009-03-15

46

Safety considerations of active process water system shutdown for TAPP - 3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)

2005-12-01

47

Ashbrook Simon-Hartley Profile on Environmental Expert  

Wastenet

...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Create Free Account ...

48

Ashbrook Simon-Hartley Profile on Environmental Expert  

Wastenet

...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Bulletins Environmental Expert ...

49

/l//IIl/ Kennedy Space Center, Florida 12899  

Science.gov (United States)

inhi bi Led ethylene glycol-water solutions for Apol lo spacecraft en- vironmental control systems (I), the concentration of sodium sulfi te ...

50

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

51

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

52

The building tomorrow and after..; Le batiment demain et apres-demain..  

Energy Technology Data Exchange (ETDEWEB)

During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)

1998-01-01

53

Radionuclide X-ray fluorescence analysis of drinking water using preconcentration of trace metals on chelating cellulose exchanger ostsorb-oxin  

International Nuclear Information System (INIS)

Determination of Cr, Fe, Cu, Zn and Pb in drinking water preconcentrated on a chelating ion exchanger of Czechoslovak production is described. The analytical system consisted of a radionuclide source "2"3"8Pu, a Si/Li semiconductor detector and a multichannel analyzer. Results are compared with trehshold limit values recommended for drinking water. (author) 9 refs.; 2 figs.

1992-04-01

54

Monitoring drinking water networks by data telemanagement; Telegestion de datos para control de redes de agua potable  

Energy Technology Data Exchange (ETDEWEB)

The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)

1997-04-01

55

EFFECTIVE CONTROL OF SECONDARY WATER POLLUTION FROM FLUE GAS DESULFURIZATION SYSTEMS  

Science.gov (United States)

The report describes tests to demonstrate the feasibility of using a vertical-tube, falling-film, vapor-compression evaporator to concentrate waste water from a flue gas desulfurization (FGD) process. Tests showed that waste water from the Chiyoda FGD process can be concentrated ...

56

Effect of design improvements in heavy water management systems to reduce heavy water losses and tritium releases at Wolsong 2,3 and 4  

International Nuclear Information System (INIS)

Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of ...

1994-03-01

57

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

58

Daytime Raman lidar measurements of water vapor during the ARM 1997 water vapor intensive observation period  

Energy Technology Data Exchange (ETDEWEB)

Because of the importance of water vapor, the ARM program initiated a series of three intensive operating periods (IOPs) at its CART (Cloud And Radiation Testbed) site. The goal of these IOPs is to improve and validate the state-of-the-art capabilities in measuring water vapor. To date, two of the planned three IOPs have occurred: the first was in September of 1996, with an emphasis on the lowest kilometer, while the second was conducted from September--October 1997 with a focus on both the upper troposphere and lowest kilometer. These IOPs provided an excellent opportunity to compare measurements from other systems with those made by the CART Raman lidar. This paper addresses primarily the daytime water vapor measurements made by the lidar system during the second of these IOPs.

1998-04-01

59

Effect of water content on the activity of lipase-hydrolysis of olive oil in reverse micelles. Gyakuso micelle nai ni okeru lipase no olive oil kasui bunkai hanno no gansuiritsu izonsei  

Energy Technology Data Exchange (ETDEWEB)

Hydrolysis of olive oil by Chromobacterium viscosum lipase was studied in a reverse micellar system of a anionic surfactant Aerosol OT (AOT) and isooctane. Different methods of solubilization of the micellar system afford specific dependence of enzymatic activity of the lipase on the water content in the micelles. In an injection method, water content is controlled by the amount of injected water, which determines the micelle size and hydrophobicity of the micelle without salt addition and changes reversibly the conformation of lipase corresponding to the change of lipase activity. The activity reaches the maximum at a water content (water/AOT)of 7. In a phase transfer method, water content is determined by salt concentration in the aqueous phase in contact with micelles and the water content ...

1992-01-10

60

Development of a probabilistic timing model for the ingestion of tap water.  

Energy Technology Data Exchange (ETDEWEB)

A contamination event in a water distribution system can result in adverse health impacts to individuals consuming contaminated water from the system. Assessing impacts to such consumers requires accounting for the timing of exposures of individuals to tap-water contaminants that have time-varying concentrations. Here we present a probabilistic model for the timing of ingestion of tap water that we developed for use in the U.S. Environmental Protection Agency's Threat Ensemble Vulnerability Assessment and Sensor Placement Tool, which is designed to perform consequence assessments for contamination events in water distribution systems. We also present a statistical analysis of the timing of ingestion activity using data collected by the American Time Use Survey. The results of the analysis provide the basis for ...

2009-01-01

61

Water consumption of a six-year-old river red gum plantation in the Southern Zagros Mountains, Iran  

British Library Electronic Table of Contents (United Kingdom)

Water is the most important limiting factor in the development of arid environments; therefore, optimization of water use is a necessity in desert reclamation projects. Evapotranspiration of a 6-year-old river red gum (Eucalyptus camaldulensis Dehnh.) plantation, located in a sedimentation basin of an artificial recharge of the Gareh Bygone Plain groundwater system in Iran?s southern Zagros Mountains, was studied during a 7-month period. A neutron moisture probe was used to monitor soil water changes in the root zone. Soil water depletion following rapid drainage for blocks receiving relatively high, medium and low volumes of floodwater were 809.6, 312.4, and 203.1 mm, respectively, for a 150-day period. Soil water potential during most of the study period was below ?1.5 MPa. This study pr...

2007-01-01

62

Source and mobility of minor and trace elements in a volcanic aquifer system: Mt. Vulture (southern Italy)  

British Library Electronic Table of Contents (United Kingdom)

In this paper we provide a geochemical investigation on 34 groundwater samples in the Mt. Vulture volcanic aquifer representing one of the most important groundwater resources of the southern Italy pumped for drinking and irrigation supply. The present study includes the first data on the abundance and mobility of minor and trace elements and the thermodynamic considerations on water-rock interaction processes in order to evaluate the conditions of alkali basalt weathering by waters enriched in magma-derived CO2. The results highlight the occurrence of two hydrofacies: bicarbonate alkaline-earth and alkaline waters deriving from low-temperature leaching of volcanic rocks of Mt. Vulture, and bicarbonate-sulfate-alkaline waters (high-salinity waters) related to prolonged water circulation in...

2011-01-01

63

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

64

Emergency reactor core cooling device  

International Nuclear Information System (INIS)

The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In ...

1993-03-16

65

Safety analysis and justification for modification of auxiliary feed-water system in Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The major feed-water line break accident is re-analyzed, which is based on Guangdong Daya Bay nuclear power station final safety analysis report, to justify the impacts of the decreasing of auxiliary feed-water flow rate on the safety margin in Daya Bay. The results showed that the accident analysis can meet the demands of acceptance criteria with the auxiliary feed-water flowrate decreasing from 45 m"3/h to 41.8 m"3/h, and enough safety margin is still retained

2002-06-01

66

System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate  

Energy Technology Data Exchange (ETDEWEB)

Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.

1989-08-01

67

Innovative technology summary report: in situ air stripping using horizontal wells  

Energy Technology Data Exchange (ETDEWEB)

In situ air stripping (ISAS) technology was developed to remediate soils and ground water contaminated with volatile organic compounds (VOCs) both above and below the water table. ISAS employs horizontal wells to inject (sparge) air into the ground water and vacuum extract VOCs from vadose zone soils. The innovation is creation of a system that combines two somewhat innovative technologies, air sparging and horizontal wells, with a baseline technology, soil vapor extraction, to produce a more efficient in situ remediation system.

1995-04-01

68

Freezing phenomena in ice-water systems  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of solidification and melting are reviewed. The properties of water and ice and the phase diagram of water are discussed with special emphasis on ice density. A concise account of the freezing process and the Stefan problem is presented. To this end, the four stages of freezing are identified, supercooling, nucleation and the formation of dendritic ice, the growth of concentric rings of solid ice at 0{sup o}C and the final cooling of the solid ice are treated in some detail. The subject of bursting of pipes is given particular emphasis. Attention is drawn to a common misconception on pipe bursting and to misleading relationships for the computation of freezing time for ice blockage. Several current applications of melting and freezing systems are outlined. (author)

2002-09-01

69

A multilayered acoustic hyperlens with acoustic metamaterials  

British Library Electronic Table of Contents (United Kingdom)

The acoustic hyperlens can be realized by an alternating layered structure of water and fluid with negative mass density. Based on this alternating layered principle, we propose that an acoustic metamaterial consisting of three layers in water background can be designed to replace the fluid with negative mass density. The effective mass density and bulk modulus of the system which is composed of acoustic metamaterial and water are functions of the frequency. The effective mass density of such a system is close to the negative mass density of the fluid at a specific frequency; thus an acoustic metamaterial hyperlens can be achieved.

2011-01-01

70

The Philadelphia Marriott: A convention center flagship hotel  

Energy Technology Data Exchange (ETDEWEB)

This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.

1997-01-01

71

Rural residential application of geothermal heat pump. Final grant report  

Energy Technology Data Exchange (ETDEWEB)

A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)

1982-07-30

72

Identification of source and recharge zones in an aquifer system from water stable isotope. Case Study Bajo Cauca Antioqueno  

International Nuclear Information System (INIS)

Hydrology and hydrogeochemical are auxiliary techniques to valid conceptual hydrogeology an recharge models. Stable isotopes from water trace sources and path flow and Tritium indicates age. This paper is about the use of D 18, D2H y 3H to study the aquifer system on Bajo Cauca antioqueno.

73

Heating and hot water: the installations; Chauffage et eau chaude: les installations  

Energy Technology Data Exchange (ETDEWEB)

This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)

2005-07-01

74

Doublet III limiter/armor update  

Energy Technology Data Exchange (ETDEWEB)

The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.

1983-12-01

75

Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. ...

2004-05-01

76

Solar desalination using humidification dehumidification processes. Part I. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. ...

2004-05-01

77

Final report for the DOE Suede Project, (solar utilization/economic development and employment project)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy Conservation Devices for (8) one bedroom homes. CDC ...

1983-10-19

78

Binary heat pump system. Binary heat pump system  

Energy Technology Data Exchange (ETDEWEB)

This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This system is characterized by the simultaneous operation of cooling and heating, high ...

1993-11-30

79

A distributed control framework for smart grid development: Energy/water system optimal operation and electric grid integration  

British Library Electronic Table of Contents (United Kingdom)

In this work, we propose a conceptual distributed control framework for electrical grid integrated with distributed renewable energy generation systems in order to enable the development of the so-called ''smart electrical grid''. First, we introduce the key elements and their interactions in the proposed control architecture and discuss the design of the distributed control systems which are able to coordinate their actions to account for optimization considerations on the system operation. Subsequently, we focus on a specific wind/solar energy generation system connected to a reverse osmosis water desalination system and the electrical grid and design two supervisory predictive controllers via model predictive control to operate the integrated system taking into account short-term and lo...

2011-01-01

80

The preparation of highly absorbing cellulosic copolymers -the cellulose acetate/propionate-g. co-acrylic acid system  

Energy Technology Data Exchange (ETDEWEB)

A series of copolymers based on the cellulose acetate/propionate-g.co-acrylic acid system has been prepared under radiation-induced control. These copolymers have been assessed for their water-retention capacity both in an unmodified state and after ''decrystallization'' or ''neutralization'' treatments. The grafting of acrylic acid onto the cellulose acetate/propionate had little effect on the water retention power of the cellulose acetate/propionate. However, improvements to the water retentivity was obtained after ''decrystallization'' procedures had been carried out on the copolymers using selected alkali metal salts with methanol as the continuous medium. The water-retentivity of the copolymers increased with increase in the extent of grafting, though the effect is less ...

1990-01-01

81

Marine pastures: a by-product of large (100 megawatt or larger) floating ocean thermal power plants. Progress report, February 1, 1976--April 30, 1976  

Science.gov (United States)

Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep ...

1976-01-01

82

Characterization of Y2BaCuO5 nanoparticles synthesized by nano-emulsion method  

British Library Electronic Table of Contents (United Kingdom)

Nanoscale yttrium?barium?copper oxide (Y2BaCuO5, Y211) particles were synthesized using the emulsion method and the solution method. The basic water-in-oil (w/o) emulsion system consisted of n-octane (continuous oil phase), cetyltrimethylammonium bromide (cationic surfactant), butanol (cosurfactant) and water. The composition of the emulsion system was varied and characterized by measuring the conductivity of the solutions and droplet size. The droplet size of emulsion was determined by using the dynamic light scattering method. The water content, cosurfactant content, and surfactant/n-octane ratio affected the droplet size which was in the range of 3?8?nm, and hence the w/o emulsion system was referred to as a nano-emulsion system. A model was used to verify the droplet size. The influenc...

2007-01-01

83

An experimental integrated absorption heat pump effluent purification system. Pt. 1: Operating on water/lithium bromide solutions  

Energy Technology Data Exchange (ETDEWEB)

The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate the likely results ...

1999-05-01

84

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven ...

1991-10-22

85

ICPP water inventory study project summary report  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Chemical Processing Plant (ICPP) Water inventory Study was initiated in September 1993 with the formation of a joint working group consisting of representatives from DOE-ID, State of Idaho INEL Oversight Program, US Geological Survey, and INEL employees to investigate three issues that had been identified by the INEL Oversight Program at ICPP: (1) the water inventory imbalance at ICPP, (2) the source of water infiltrating into the Tank Farm vault sumps, and (3) the source of water providing potential recharge to perched water bodies underlying ICPP. These issues suggested that water was being lost from the ICPP distribution system. The INEL Oversight Program was concerned that the unaccounted for water at ICPP could be spreading contaminants that have been released over the past 40 years of operations of ICPP, ...

1994-01-01

86

Challenges in commissioning and operation of 'first-of -its- kind' liquid zone control system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the ...

2006-11-13

87

On the theory of mechano-catalytic water-splitting system  

Energy Technology Data Exchange (ETDEWEB)

A theory has been developed for the mechano-catalytic water-splitting, which is the system of simultaneous H{sub 2} and O{sub 2} evolution by stirring the powder of an oxide semiconductor in pure water under the condition that the stirring rod must be kept in contact with the surface of the glass vessel. The kinetic equations and the coupling strength of the frictional energy conversion between mechanical and electrical systems are calculated . The total system composed of the formation of the dangling bonds on the glass surface, the trapping of the semiconductor particles at the microcrevice of the glass surface, the strong field inside the fine particles due to the frictional electricity, the mechanism of charge transfer from the semiconductor to the stirring rod, the hopping conduction of positive hole, the electric current density injected into water from ...

2000-10-01

88

Determination of time-dependent void fraction distribution in bubbly two-phase flow by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy ...

1995-01-01

89

Three Dimensional Visualization for the Steam Injection into Water Pool using Electrical Resistance Tomography  

International Nuclear Information System (INIS)

The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool

2010-10-01

90

Shallow groundwater nitrogen and denitrification in a newly afforested, subirrigated riparian buffer  

British Library Electronic Table of Contents (United Kingdom)

Summary 1. The EU -Nitrates Directive- (Directive 91/676/EEC) and the WFD (Water Framework Directive 2000/60/EEC) introduced a series of measures designed to reduce and prevent water pollution caused or induced by nitrates from agricultural sources. Therefore, there is an urgent requirement to control the nitrate concentration in freshwater. The objective of this paper was to verify the potential capacity of a specifically designed afforested riparian zone in removing the excess of nitrogen from river water. 2. A buffer zone was set with irrigation ditches, to produce a subsurface water flow carrying water from the study river through the buffer strip to drainage ditches. This experimental system enables the co-occurrence of two main processes: vegetation/microbial nitrogen uptake and deni...

2011-01-01

91

Origin of water salinity in the coastal Sarafand aquifer (South-Lebanon)  

International Nuclear Information System (INIS)

Author.The geochemical and isotopic study, based on the analysis of twenty water samples from well in the coastal plain of Sarafand (South-Lebanon), permit to eliminate the hypothesis of marine intrusion in this aquifer. The increase of salinity observed in certain wells is due to the contamination of cretaceous aquifer water by the quaternary formations. The two poles of mixing are respectively characterized: by weak tritium contents (between 2 and 3 UT) and a value of stable isotopes (-5,9<0,18<-5,5) corresponding to the appearance of cretaceous formation area; by the high tritium contents and enrichment relative to heavy isotope in the mineralized water of superficial formations. On the other hand, the isotope contents permit the set a rapid renewal of the cretaceous aquifer water due to quick circulation in the Karstic system

92

Growth and gas exchange response to water shortage of a maize crop on different soil types  

British Library Electronic Table of Contents (United Kingdom)

The effect of water shortage on growth and gas exchange of maize grown on sandy soil (SS) and clay soil was studied. The lower soil water content in the SS during vegetative growth stages did not affect plant height, above-ground biomass, and leaf area index (LAI). LAI reduction was observed on the SS during the reproductive stage due to early leaf senescence. Canopy and leaf gas exchanges, measured by eddy correlation technique and by a portable photosynthetic system, respectively, were affected by water stress and a greater reduction in net photosynthetic rate (A N) and stomatal conductance (g s) was observed on SS. Chlorophyll and carotenoids content was not affected by water shortage in either condition. Results support two main conclusions: (1) leaf photosynthetic capacity was unaffec...

2009-01-01

93

Design of automatic monitoring network for the water quality management of river basin  

Energy Technology Data Exchange (ETDEWEB)

In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purpose of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for different locations. Proposed methodology is demonstrated ...

1996-04-30

94

Contribution of climatic and anthropogenic effects to the hydric deficit of peatlands  

British Library Electronic Table of Contents (United Kingdom)

Abstract The present study makes use of a detailed water balance to investigate the hydrological status of a peatland with a basal clay-rich layer overlying an aquifer exploited for drinking water. The aim is to determine the influence of climate and groundwater extraction on the water balance and water levels in the peatland. During the two-year period of monitoring, the hydrological functioning of the wetland showed a hydric deficit, associated with a permanent unsaturated layer and a deep water table. At the same time, a stream was observed serving as a recharge inflow instead of draining the peatland, as usually described in natural systems. Such conditions are not favourable for peat accumulation. Field investigations show that the clay layer has a high hydraulic conductivity (from 11...

2011-01-01

95

Base flow hydrology and water quality of an Ozarks spring and associated recharge area, southern Missouri, USA  

British Library Electronic Table of Contents (United Kingdom)

Human activities in the karst Ozark Plateaus can impact water quality of springs where surface water is rapidly transferred to subsurface conduits. Bennett Spring, in southern Missouri, is the fourth largest spring in the state and supports local tourism activities. Questions regarding poorly functioning on-site wastewater systems (OWS) have raised concerns over the long-term water quality of the spring. This study reports the results of a surface water quality monitoring program in the recharge area where monthly samples were collected at base flow to identify potential pollution sources to the spring. Base flow hydrology of the recharge area was highly variable over the study period, which was drier than normal, causing an incomplete sampling record due to no flow conditions at some site...

2011-01-01

96

Antioxidant activity in banana peel extracts: Testing extraction conditions and related bioactive compounds  

British Library Electronic Table of Contents (United Kingdom)

Banana (Musa acuminata Colla AAA) peel extracts obtained in this work had a high capacity to scavenge 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2prime-azino-bis(3-ethylbenzothiazoline)-6-sulfonic acid (ABTS+) free radicals, and they were also good lipid peroxidation inhibitors. Acetone:water extracts were considerably more effective (compared with methanol, ethanol, acetone, water, methanol:water or ethanol:water) at inhibiting the peroxidation of lipids in the b-carotene/linoleic acid system or scavenging free radicals. However, aqueous extracts had a high capacity to protect lipids from oxidation in the thiobarbituric acid reactive substances (TBARS) test, as well as in the b-carotene bleaching assay. In addition, acetone:water most efficiently extracted all extractable components (54+-...

2010-01-01

97

Raft River monitor well potentiometric head responses and water quality as related to the conceptual ground-water flow system  

Energy Technology Data Exchange (ETDEWEB)

Ground-water monitoring near the Raft River site was initiated in 1974 by the IDWR. This effort consisted of semiannual chemical sampling of 22 irrigation wells near the Raft River geothermal development area. This program yielded useful baseline chemical data; however, several problems were inherent. For example, access to water pumped from the wells is limited to the irrigation season (April through September). All the wells are not continuously pumped; thus, some wells that are sampled one season cannot be sampled the next. In addition, information on well construction, completion, and production is often unreliable or not available. These data are to be supplemented by establishing a series of monitor wells in the proposed geothermal withdrawal and injection area. These wells were to be located and designed to provide data necessary for evaluating and predicting the impact of geothermal development on the Shallow Aquifer ...

1982-09-01

98

Model for simulation of freezing and thawing processes in building materials  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model for simultaneous heat and moisture transfer under freezing-thawing in porous hygroscopic material. Even below O{sup o}C, unfrozen liquid water exists in the material which plays an important role in the processes. The model takes into account the existence of unfrozen liquid water. The system is treated as a three-(gas, liquid and solid) phase system of water. Moisture chemical potential is used as a moisture potential. Under freezing, moisture chemical potential is a unique function of local temperature. So, during freezing, two unknown variables to be solved are solid water content and moisture potential or temperature. A simple example of simulation for freezing processes is shown. (author)

2001-07-01

99

Interpolating atmospheric water vapor delay by incorporating terrain elevation information  

British Library Electronic Table of Contents (United Kingdom)

In radio signal-based observing systems, such as Global Positioning System (GPS) and Interferometric Synthetic Aperture Radar (InSAR), the water vapor in the atmosphere will cause delays during the signal transmission. Such delays vary significantly with terrain elevation. In the case when atmospheric delays are to be eliminated from the measured raw signals, spatial interpolators may be needed. By taking advantage of available terrain elevation information during spatial interpolation process, the accuracy of the atmospheric delay mapping can be considerably improved. This paper first reviews three elevation-dependent water vapor interpolation models, i.e., the Best Linear Unbiased Estimator in combination with the water vapor Height Scaling Model (BLUE?+?HSM), the Best Linear Unbiased Es...

2011-01-01

100

Progress on the investigation of coal-water-slurry fuel combustion in a medium-speed diesel engine; Part 3-accumulator injector performance  

Energy Technology Data Exchange (ETDEWEB)

Coal-water-slurry (CWS) engine tests designed to evaluate a new accumulator-based injection system are described in this paper The new injection system was found to improve CWS burnout considerably at both full and part engine loads. The peak cylinder firing pressure when operating with CWS was no higher than when operating with diesel oil. These data demonstrates the improved engine performance that can be achieved with the accumulator-based injection system.

1989-07-01

101

FY1998 research report on the basic research on geothermal district heating in Kamchatka, Russia; 1998 nendo Roshia Renpo Kamchatka shu ni okeru chinetsu riyo ni yoru chiiki danbo ni kansuru kiso chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump ...

1999-05-01

102

Sustainable water resources management in Pakistan  

International Nuclear Information System (INIS)

Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On ...

2004-06-07

103

Generalized simulation model for reservoir system analysis. Technical paper  

Energy Technology Data Exchange (ETDEWEB)

This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. ...

1992-03-01

104

LiNO3 molten salt assisted synthesis of spherical nano-sized YSZ powders in a reverse microemulsion system  

British Library Electronic Table of Contents (United Kingdom)

Spherical nano-sized YSZ (yttria stabilized ZrO2) powders were successfully synthesized via a reverse microemulsion system. The water droplets in the microemulsion system of yclohexane/water/span85/Triton X-100/hexyl alcohol can act as the nano-reactors which solubilize zirconium oxychloride and ammonia water separately. The minute original reactors are favor to the formation of nano-sized spherical YSZ powders and the dispersibility of the powders can be controlled effectually by adjusting the weight ratio of the LiNO3 molten salt to the precursor. The phase transformation from cubic to monoclinic starts at and 500??C and finally monoclinic and cubic phase with increased crytallinity coexist at 800??C. The effect of LiNO3 molten salt in the formation of YSZ powders was also discussed.

2008-01-01

105

Identification and robust water level control of horizontal steam generators using quantitative feedback theory  

British Library Electronic Table of Contents (United Kingdom)

In this paper, a robust water level control system for the horizontal steam generator (SG) using the quantitative feedback theory (QFT) method is presented. To design a robust QFT controller for the nonlinear uncertain SG, control oriented linear models are identified. Then, the nonlinear system is modeled as an uncertain linear time invariant (LTI) system. The robust designed controller is applied to the nonlinear plant model. This nonlinear model is based on a locally linear neuro-fuzzy (LLNF) model. This model is trained using the locally linear model tree (LOLIMOT) algorithm. Finally, simulation results are employed to show the effectiveness of the designed QFT level controller. It is shown that it will ensure the entire designer's water level closed loop specifications.

2011-01-01

106

A Computer Simulation of the Electronic Structure of Leucine in Aqueous Solution  

British Library Electronic Table of Contents (United Kingdom)

In order to obtain the electronic structure of leucine (Leu) in aqueous solution, we studied three systems: Leu+7H2O, Leu+8H2O and Leu+9H2O. The results indicated that the system Leu+8H2O was the only choice which was both acceptable and doable: its computational effort was affordable, and it could simulate a main part of the solvent effect on the electronic structure of Leu in solution. Based on the system Leu+8H2O, all-electron, ab initio calculations were performed to construct an equivalent potential of water for the electronic structure of Leu with dipoles. The results showed that the main effect of water on the electronic structure of Leu was raising the occupied states about 0.0824 Ry on average, and broadening the energy gap by 11%. The water effect on the electronic structure of L...

2011-01-01

107

New intelligent monitor for CANDU type NPP  

International Nuclear Information System (INIS)

Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy ...

2009-10-12

108

Surface wettability effect on an indirect evaporative cooling system  

Energy Technology Data Exchange (ETDEWEB)

Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A dynamic contact analyzer was used to quantitatively measure the wetting properties ...

1996-11-01

109

Final ROI Report - Technology Transfer of Waste-Reducing Groundwater Sampling Systems  

Energy Technology Data Exchange (ETDEWEB)

This report presents the findings of a U.S. DOE Environmental Management technology transfer initiative of waste-reducing ground water sampling systems between Savannah River Site (SRS) and Lawrence Livermore National Laboratory (LLNL) which occurred during fiscal years 2001 and 2002. The report describes the collaboration between the two sites, the deployment of the Savannah River Site Purge Water Management System at LLNL, the changes made to that system for use at LLNL, and documents the return-on-investment derived from the system's use at LLNL as well as other benefits generated through this inter-laboratory collaboration. An evaluation of the deployment of the LLNL EasyPump sampling technology at SRS will be covered in a separate report from SRS.

2002-09-30

110

Canadian R&D on oil-fired combustion systems  

Energy Technology Data Exchange (ETDEWEB)

This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating systems, as well as ...

1996-07-01

111

Water chemistry in the water-vapor circuit at Angra II: evolution of the operational concepts and canceling of the condensed polishing system; Quimica da agua do circuito agua-vapor de Angra II: evolucao do conceito operacional e o cancelamento do sistema de polimento do condensado  

Energy Technology Data Exchange (ETDEWEB)

The chemical operational concept originally established for the water-steam circuit of Angra II nuclear power plant has undergone several modifications throughout the development of the project. This work discusses the two main modifications giving special attention to the costs involved and analyses the main points and the consequences of such modifications 1 ref., 4 figs., 2 tabs.

1995-12-31

112

Use of the River Saale cascade in terms of energy supply and water control. Energetische und wasserwirtchaftliche Nutzung der Saale-Kaskade  

Energy Technology Data Exchange (ETDEWEB)

The river Saale cascade consists of seven reservoirs with a total capacity of approx. 415 Mio. m[sup 3]. The entire reservoir system covers a catchment area of 1665 km[sup 2]. The water management tasks extend to the following main fields: flood protection upkeep of minimum water stock, salt load control and power generation. The energy supply capacity of the cascade is mainly used by pumped storage plants. The last of these plants, Hohenwarte II, was put into service in 1963. (orig.)

1993-01-01

113

The SBWR (simplified boiling water reactor) thermal-hydraulic performance analysis and testing  

Science.gov (United States)

Utility interest has recently increased in potential future nuclear units that combine the characteristics of smaller size, greater simplicity, and more passive safety features. In response to such interest, General Electric (GE) began development in 1982 of a 600-MW(electric) reactor with simplified power generation and safety systems. This paper provides an overview of the simplified boiling water reactor (SBWR) design, with emphasis on the thermal-hydraulic aspects of the design. The SBWR is a natural circulation reactor requiring no pumps to circulate the water through the core.

1989-11-01

114

Rapid and continuous hydrothermal crystallization of metal oxide particles in supercritical water  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on hydrolysis of 10 metal salt aqueous solutions of 6 metal oxides that was conducted in supercritical water. Continuous and rapid production of metal oxide fine particles was achieved by mixing a metal salt aqueous solution with preheated water fed from another line. The reaction time required was less than 2 min. Particle size, morphology, and crystal structure of the obtained metal (hydrous) oxides were examined. Particle size (20 to 600 nm) was different among the system but the size range was relatively narrow in all the cases.

1992-04-01

115

Pitting corrosion of steel pipeline in oil-water-gas multiphase flow system  

Energy Technology Data Exchange (ETDEWEB)

Severe pitting corrosion occurred in a horizontal steel pipeline used to transport multiphase fluid, including water, oil, and natural gas, after 2 months of service. The pitting corrosion rate was up to 42 mm/year. Chemical analysis, X-ray diffractometry, and EDAX showed that the corrosion products mainly consisted of Fe9S8, FeCO3, and NaCl. Calcium containing inclusions were also found in the matrix of the steel, which may accelerate corrosion. The early failure was attributed to the high proportion of water, the slow flow velocity, and the use of unqualified material. (Author)

2000-07-01

116

Microwave drying of fine coal  

Energy Technology Data Exchange (ETDEWEB)

Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.

1989-03-01

117

In situ bioremediation using horizontal wells  

Energy Technology Data Exchange (ETDEWEB)

In Situ Bioremediation (ISB), which is the term used in this report for Gaseous Nutrient Injection for In Situ Bioremediation, remediates soils and ground water contaminated with volatile organic compounds (VOCs) both above and below the water table. ISB involves injection of air and nutrients (sparging and biostimulation) into the ground water and vacuum extraction to remove .VOCs from the vadose zone concomitant with biodegradation of VOCs. The innovation is in the combination of 3 emerging technologies, air stripping, horizontal wells, and bioremediation via gaseous nutrient injection with a baseline technology, soil vapor extraction, to produce a more efficient in situ remediation system.

1995-04-01

118

Effect of synthetic detergents on germination of fern spores  

Energy Technology Data Exchange (ETDEWEB)

Synthetic detergents constitute one of the most important water pollutants by contaminating the lakes and rivers through domestic and industrial use. Considerable information is now available for the adverse effects of detergents an aquatic fauna including fish, algae, and higher aquatic plants. Marked inhibition of germination in orchids and brinjals and of seedlings growth in raddish suggest that rapidly growing systems could be sensitive to detergent polluted water. The present study of the effect of linear alkyl benzene sulphonate on germination of the spores of a fern, Diplazium esculentum aims at the understanding of the effects of water pollution on pteridophytes and the development of spore germination assay for phytoxicity evaluation.

1986-12-01

119

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

120

Biotoxicity characterization of a produced-water discharge in Wyoming  

International Nuclear Information System (INIS)

The objectives of this paper are to document the physicochemical and aquatic toxicological quality of a beneficial-use produced-water discharge and its effect on a receiving stream in Wyoming. Fish and water-flea survival, growth, and reproduction tests indicated that the discharge and all other sampling stations passed the state effluent biomonitoring acute toxicity testing endpoints. while benthic macroinvertebrates were absent at the discharge point designated by the Natl. Pollutant Discharge Elimination System (NPDES), productive and reproducing populations were present at all other downstream and mixing-zone stations. This investigation confirmed the validity of the beneficial-use subcategory for this oilfield discharge.

121

Sorption equilibrium and hydration studies of lysozyme: water activity and 360-MHz proton NMR measurement  

International Nuclear Information System (INIS)

An attempt to determine lysozyme hydration by employing a proton nuclear magnetic resonance (NMR) spin-echo technique and to correlated such measurements with the 20 "0C sorption equilibrium data is made. Determinations of specific site hydration for lysozyme, as well as proton NMR transverse relaxation rates for five different types of water populations in the lysozyme-water system, are presented over the whole range of lysozyme concentrations. The proton spin-echo NMR results are consistent with a three-component analysis of the sorption isotherm up to 70% water content, above which two additional water populations are identified by 360-MHz proton NMR spin-echoes. On the basis of the proton NMR results, a major component (III) of the lysozyme sorption isotherm is assigned to the water trapped between lysozyem molecules, whose relaxation rate is increased by ...

122

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion ...

1993-08-15

123

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

124

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

125

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

126

Reliability assessment of hydrothermal generation systems containing pumped storage plant  

Energy Technology Data Exchange (ETDEWEB)

Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).

1991-11-01

127

Sensing the physical and nutritional status of the root growth environment  

Environmental Research Database

DescriptionAbstract of Research Proposal The root environment has a major effect on crop growth, both directly through the supply of water and nutrients to the shoot, and indirectly through root to shoot signalling. Better management of crop root systems through agronomic and genetic means has the potential to improve the efficiency of water and nutrient uptake, and limit root restrictions to crop growth. However, progress in this area is currently limited by the lack of sensors for in situ estimates of [continued...

2004-01-30

128

Oil and Natural Gas Technology: Development of Next Generation Multiphase Pipe Flow Prediction Tools. Final Report.  

Science.gov (United States)

The developments of fields in deep waters (5000 ft and more) is a common occurrence. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oil-and water possibly along with sand, hydrates, and wax...

2008-01-01

129

In situ air stripping using horizontal wells. Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

In-situ air stripping employs horizontal wells to inject or sparge air into the ground water and vacuum extract VOC`S from vadose zone soils. The horizontal wells provide better access to the subsurface contamination, and the air sparging eliminates the need for surface ground water treatment systems and treats the subsurface in-situ. A full-scale demonstration was conducted at the Savannah River Plant in an area polluted with trichloroethylene and tetrachloroethylene. Results are described.

1995-04-01

130

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

131

Development of Next Generation Multiphase Pipe Flow Prediction Tools. Semi-Annual Technical Report. Reporting Period: June 2006 through November 2006.  

Science.gov (United States)

The developments of oil and gas fields in deep waters (5000 ft and more) will become more common in the future. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oiland water possibly along wi...

2007-01-01

132

Assimilation of Remote Sensing Data into Shelf Sea Hydrodynamic Models  

Environmental Research Database

DescriptionRemote sensing of the sea surface from satellites in near-polar orbits has contributed greatly to our understanding of the links between physical and biological processes in marine systems. However most of this progress has been made in open oceanic waters or major upwelling areas, and many unresolved problems are encountered in coastal regions and shelf seas. In these optically complex waters, quantitative remote sensing requires a more sophisticated interpretation strategy than that implemente [continued...

133

Wildlife Monitoring Program Plan - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Wildlife Monitoring System Schematic .......................... 40 ...... sentinel species - healthy fish are placed in an environment of water (where they arc not .... The way ir! which data for the fnre mdor study groups will be gathered tor managciacilt ...... Earth Resources Aircraft Program (ERAP) Camera ...

134

The Surface Water and Ocean Topography (SWOT) - NASA  

Science.gov (United States)

The ratio of particle velocity to translation speed exceeds 1 for 98% of .... The westward movement of the meandering jet and eddy system transports nutrient- rich ...... J. Hydrometeor., 4, 1044-1066. Gedney, N., P. M. Cox, H. Douville, ...

135

Recovering heat from the cupola stack  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).

1986-01-01

136

NOVEL EMBEDDED CERAMIC ELECTRODE SYSTEM TO ACTIVATE NANOSTRUCTURED TITANIUM DIOXIDE FOR DEGRADATION OF MTBE  

Science.gov (United States)

A novel reactor combining a flame-deposited nanostructured titanium dioxide film and a set of embedded ceramic electrodes was designed, developed and tested for degradation of methyl tert-butyl ether (MTBE) in water. On applying a voltage to the ceramic electrodes, a surface coro...

137

Isolation and characterization of a new Cytophaga species implicated in a work-related lung disease.  

UK PubMed Central (United Kingdom)

A yellow-pigmented, gram-negative, gliding bacterium isolated from an industrial water spray air humidification system was implicated as a causative agent in several occurrences of lung disease with...Full Text Available

1984-11-01

138

Integrated Bow Waterjet for Amphibious Vehicles.  

Science.gov (United States)

Experiments were conducted with a scale model of an amphibious vehicle towed in calm water. Pressure distribution along the submerged bow and hull bottom was determined for a range of vehicle speed. A waterjet system with a bow intake and an axial flow im...

1983-01-01

139

Incident report: spillage of reactor coolant at Wolsung  

Energy Technology Data Exchange (ETDEWEB)

Late last year the Wolsung Candu in Korea suffered an incident which resulted in heavy water being released from the primary system into the containment. With the unit now back at full power, this article examines the causes of the incident and the action which is being taken to prevent it happening again.

1985-05-01

140

Human choice and climate change. Volume 2: Resources and technology  

Energy Technology Data Exchange (ETDEWEB)

Foreward: Preface; Introduction; The natural science of global climate change; Land and water use; Coastal zones and oceans; Energy and industry; Energy and social systems; Technological change; and Sponsoring organizations, International Advisory Board, and project participants.

1997-12-31

141

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

142

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

143

Engineering Task Plan for Water Supply for RMCS Spray Wash Trailer  

Energy Technology Data Exchange (ETDEWEB)

This ETP defines the task and deliverables associated with the design, fabrication and testing of an improved spray wash system for the Rotary Mode Core Sampling (RMCS)Spray Wash Trailer.

2000-04-20

144

Dimensions and approaches for Third World city water security.  

UK PubMed Central (United Kingdom)

A rapid expansion of urban systems, particularly in less-developed countries, pose considerable challenges. Urbanization also provides opportunities for socio-economic progress. Relative contribution...Full Text Available

2003-12-29

145

Development of Tritium Removal Technology.  

Science.gov (United States)

Liquid Phase Catalytic Exchange (LPCE)- Cryogenic Distillation(CD) process was studied which could be available for an optimal tritium removal process of pressurized heavy water reactor system at Wolsung nuclear power plant in the near future. Based upon ...

1986-01-01

146

Development and Evaluation of a Reflective Solar Disinfection Pouch for Treatment of Drinking Water  

UK PubMed Central (United Kingdom)

A second-generation solar disinfection (SODIS) system (pouch) was constructed from food-grade, commercially available packaging materials selected to fully transmit and amplify the antimicrobial properties...Full Text Available

2004-04-01

147

Coal fueled diesel engines - 1992  

Energy Technology Data Exchange (ETDEWEB)

10 papers are presented with the following titles: coal fueled diesel engine development update at GE transportation systems; features and performance data of Cooper-Bassemer coal-fueled six-cylinder LSB engine; preliminary test data and systems analysis of a high pressure coal fuel processor/engine system concept; study for coal-water-slurry fuel combustion in a high speed diesel engine; design and operation of a medium speed 12-cylinder coal-fueled diesel engine; progress on the investigation of coal water slurry fuel combustion in a medium speed diesel engine: part 5 - combustion studies; injection characteristics of coal-water slurries in medium speed diesel equipment; coal-water slurry spray characteristics of a positive displacement fuel injection system; novel injector techniques for coal-fueled diesel engines; ...

1992-01-01

148

Economic evaluation of four types of dry/wet cooling applied to the 5-MWe Raft River geothermal power plant  

Energy Technology Data Exchange (ETDEWEB)

A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had ...

1982-07-01

149

Finalisation of design provision for active process water system shut down at TAPP-3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained ...

2006-11-13

150

Experimental and theoretical studies on humidification-dehumidification-desalination  

Energy Technology Data Exchange (ETDEWEB)

The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water ...

2006-07-01

151

Transient impurity transport by automated ion chromatography  

International Nuclear Information System (INIS)

An ion chromatograph has been modified to automatically sample ten liquid water streams from the secondary side of three pressurized water reactors, Calvert Cliffs, Unit One, Rancho Seco and McGuire, Unit 1. Sampling and measurement is semicontinuous with a cycle time of approximately five hours for 10 locations with sensitivities in the range of 0.1 to 0.5 ppb. The efficiency of the condensate polishing system and subsequent transport of sodium, chloride, and sulfate around the system can be readily followed. Sulfate has been shown to have unusual volatility into the steam phase from the steam generator as well as a tendency to pass through the condensate polisher.

1985-03-01

152

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

153

Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy  

Energy Technology Data Exchange (ETDEWEB)

Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)

2007-04-01

154

Techno-economic investigation of an air humidification-dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

This article presents a humidification-dehumidification (H.D.) process suitable for desalination of sea- and brackish water. The work correlated performance characteristics of the combination of different components in such a loop. Water yield, energy requirement and design data are evaluated as functions of different parameters. The investigation covered water to air mass ratios ranging from 60 to 80, concentration ratios between 2 and 5, at a temperature difference of between 10 and 16 C, along the liquid for dehumidification. The results showed that 76% of energy consumed in the humidifier is recovered by condensation. Increase of the concentration ratio to 5 can reduce the make-up water and rejected brine by about 58% and 24% respectively. Cost calculations show that the H.D. process has significant potential as an alternative for small capacity desalination plants and permits to operate ...

1993-08-01

155

Role of additives in wood plastic composite of water soluble monomer  

International Nuclear Information System (INIS)

Wood plastic composites are prepared under radiation of "6"0Co gamma source with simul, a low grade wood of Bangladesh using a water soluble monomer acrylamide (AM) mixed with a swelling solvent methanol, water or methanol/water (1:1) at different compositions in the presence of a number of additives and co-additives such as NVP (N-vinylpyrrolidone), TPGDA (tripropylene glycol diacrylate), TMPTA (trimethylol propane triacrylate), sulfuric acid, urea and copper sulfate. Polymer loading (PL) and tensile strength (TS) of the composites are measured. The role of these additives on the composites is also discussed. It is observed that nitrogen-atom containing-materials like urea, NVP and AM produce composites with the highest mechanical strength, and incorporation of copper into this system provides additional property of protection and preservation of the composites against attacks by insects and microbes. ...

1994-01-01

156

Road maps on research and development plans for water chemistry of nuclear power systems  

International Nuclear Information System (INIS)

Water chemistry of nuclear power plants has played an important role in reduction of personnel doses, structural materials and fuel integrity assurance, and reduction of radioactive wastes production. Further contributions are requested for advanced utilization of the LWR, advanced fuels and aging management of plants. Since water chemistry has an effect on all structure and materials immersed and at the same time affected by them, the optimum control not sticking to specific issues and covering the whole plant is required for these requests. Taking account of roles and activities of the industry, governmental institutes and academia, road maps on research and development plans for water chemistry were compiled into identified eleven items with targets and counter measures taken, such as common basic technologies, dose reduction, SCC mitigation, fuel cans corrosion/hydrogen absorption mitigation, condition based maintenance ...

2008-05-01

157

Electrochemistry Modeling of Proton Exchange Membrane (PEM) Water Electrolysis for Hydrogen Production  

International Nuclear Information System (INIS)

An electrochemistry model was developed to analyse the J-V characteristics of a Proton Exchange Membrane (PEM) water electrolyzer for hydrogen production. The Butler-Volmer equation and water transport characteristics through electrolyte membrane were employed to simulate the electrode activation over-potential and membrane ohmic over-potential, respectively. The modeling results are found to agree reasonably well with experimental data published in the literature. The parametric simulations show that the ohmic over-potential is relatively small with typical water content in the membrane. Compared with the cathode over-potential, the anode over-potential is more significant and constitutes the major source of voltage loss. The high anode over-potential is due to the relatively slow oxidation kinetics, which is related to anode material property and microstructure. This model can be integrated with a photovoltaic or wind ...

2006-06-13

158

Effect of postharvest water deficit stress on gene expression in heads of broccoli (Brassica oleracea var. italica)  

British Library Electronic Table of Contents (United Kingdom)

Harvested plant organs such as heads of broccoli (Brassica oleracea L. var. italica) experience a range of stresses that can lead to premature reduction in quality and eventual senescence. Understanding plant responses to stress may open up novel opportunities to extend postharvest life. One of the first stresses experienced by harvested organs is likely to be water deficit stress since severance of the vascular system halts the normal flux of water into the tissue. For broccoli branchlets with their cut ends held in water, transcriptome analysis based on hybridization of broccoli floret mRNA to a heterologous Arabidopsis microarray revealed that the transcript abundance of 431 genes reliably changed within 48h of harvest. Of these, transcripts of 146 genes increased and 34 genes decreased...

2011-01-01

159

Condensation heat transfer in a steam-water stratified flow  

Energy Technology Data Exchange (ETDEWEB)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)

1999-07-01

160

Condensation heat transfer in a steam-water stratified flow  

International Nuclear Information System (INIS)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)

1999-04-19

161

Instabilities during liquid migration into superheated hydrothermal systems  

Energy Technology Data Exchange (ETDEWEB)

Hydrothermal systems typically consist of hot permeable rock which contains either liquid or liquid and saturated steam within the voids. These systems vent fluids at the surface through hot springs, fumaroles, mud pools, steaming ground and geysers. They are simultaneously recharged as meteoric water percolates through the surrounding rock or through the active injection of water at various geothermal reservoirs. In a number of geothermal reservoirs from which significant amounts of hot fluid have been extracted and passed through turbines, superheated regions of vapor have developed. As liquid migrates through a superheated region of a hydrothermal system, some of the liquid vaporizes at a migrating liquid-vapor interface. Using simple physical arguments, and analogue laboratory experiments we show that, under the influence of gravity, the liquid-vapor interface may become ...

1995-01-26

162

Advanced resin cleaning system  

International Nuclear Information System (INIS)

Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)

2008-07-01

163

Manganese removal from mine waters - investigating the occurrence and importance of manganese carbonates  

International Nuclear Information System (INIS)

Manganese is a common contaminant of mine water and other waste waters. Due to its high solubility over a wide pH range, it is notoriously difficult to remove from contaminated waters. Previous systems that effectively remove Mn from mine waters have involved oxidising the soluble Mn(II) species at an elevated pH using substrates such as limestone and dolomites. However it is currently unclear what effect the substrate type has upon abiotic Mn removal compared to biotic removal by in situ micro-organisms (biofilms). In order to investigate the relationship between substrate type, Mn precipitation and the biofilm community, net-alkaline Mn-contaminated mine water was treated in reactors containing one of the pure materials: dolomite, limestone, magnesite and quartzite. Mine water chemistry and Mn removal rates were monitored over a 3-month ...

2006-08-01

164

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; ...

165

Solvent effects on biocatalysis in organic systems: equilibrium position and rates of lipase catalyzed esterification.  

Science.gov (United States)

Porcine pancreatic lipase immobilized on celite particles has been employed as a catalyst for the esterification of dodecanol and decanoic acid in a predominantly organic system. Solvent influence on the equilibrium position and on the catalyst activity has been studied using 20 solvents, including aliphatic and aromatic hydrocarbons, ethers, ketones, nitro- and halogenated hydrocarbons, and esters. The equilibrium constant for esterification correlates well with the solubility of water in the organic solvent, which in turn shows a good relationship with a function of Guttman's donor number and the electron pair acceptance index number of the solvent. This may be rationalized in terms of the requirements for solvation of water and of the reactants. The catalyst activity, measured as the initial rate of the esterification reaction, is best correlated as a function of both n-octanol-water partition ...

1991-12-01

166

Influence of two systematic parameters on the geothermal heat pump system operation  

Energy Technology Data Exchange (ETDEWEB)

In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)

2003-01-01

167

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

168

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to ...

1981-11-18

169

Corrosion and scale processes and their inhibition in simulated cooling water systems by monosaccharides derivatives  

British Library Electronic Table of Contents (United Kingdom)

A study of the ordinary mild steel/cooling water interface, with and without inhibitor, was carried out using electrochemical impedance spectroscopy (EIS). EIS spectra in uninhibited medium reveal that a layer of corrosion and scale products is formed naturally and evolves with the immersion time. Monosaccharides derivatives were used as corrosion inhibitors. Most of them exhibit good behaviour against corrosion of ordinary steel in simulated water systems. Their inhibiting efficiency increases with concentration rise and depends on molecular structure especially -OH groups' position on two adjacent carbons and their number. In addition, the effect of MoO4^2^- on the corrosion inhibition in the presence of the best inhibitor was also studied by EIS. The addition of MoO4^2^- enhanced the in...

2009-01-01

170

Study of Water Quality Value in Sub of the Stream Area of Cisadane Rivers Upstream as Reference Area Based on Macro invertebrate Composition  

International Nuclear Information System (INIS)

Specific structure of biota community condition can used as indicator for the ecosystem stability value or the waters pollution level where the aquatic biota exist. the macro invertebrates as bio indicator organism can used to assess the upper Cisadane Sub River Basin water quality. The grouping and calculation result from family number, Ept presences (sensitive macro invertebrate), Diversity index (H"'), DO value and TOC value showed 5 criteria of water quality as reference site. This criteria is used to determine water quality level from ten branches of rivers in the upper Cisadane Sub River Basin, Cijeruk districts. The biotic index calculation for ASPT (Average Score Per Taxon) and T and T (index Trihadiningrum and Tjindronegoro) is used to asses water quality based on macro invertebrate composition indicator. Both biotic index system support and give the ...

2001-11-01

171

Solar desalination using humidification-dehumidification processes. Part II. An experimental investigation  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the ...

2004-05-01

172

Solar desalination using humidification-dehumidification processes. Part II. An experimental investigation  

International Nuclear Information System (INIS)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the ...

2004-05-01

173

Solar desalination using humidification dehumidification processes. Pt. 2. An experimental investigation  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the ...

2004-05-01

174

Radiation thermocatalytic processes of hydrogen production from water  

International Nuclear Information System (INIS)

The results of studies of radiation-thermocatalytic water decomposition in the 673-773 K temperature range in the presence of BeO and titanium Y-type zeolite are presented. It is found that radiation-thermocatalytic processes of hydrogen production from water are characterized by a lower activation energy (55.4 kJ/mole) as compared with thermocatalytic processes (88.4 kJ/mole). The radiation-thermocatalytic process rate in the presence of oxide systems is not an additive sum of rates of radiation-catalytic (at 296-300 K) and thermocatalytic processes of water decomposition. On the basis of obtained results the conclusion is made that during radiation-catalytic decomposition of water in a heterogeneous system BeO + H_2O the main contribution into this process is made by excitons, radiation-chemical yields of excitons and non-equilibrium charge-carriers are ...

175

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely ...

1988-03-25

176

Microprocessor-controlled anodic stripping voltammeter for trace metal analysis in tap water  

Energy Technology Data Exchange (ETDEWEB)

The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time: a rotating cell for efficient oxygen removal and amalgam formation; and, data handling via a minicomputer or analog pen recorder. Plating and stripping potentials are controlled by a digital potentiostat; stripping is done using a staircase waveform with measurement of the current after a one msec delay. In this way charging current effects are minimized. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1-1000 ..mu..g/L Cu, 1 -2 ..mu..g/L Pb for ten ...

1984-06-01

177

Effect of water purification process in radioactive content: analysis on small scale purification plants; Efecto del proceso de purificacion de agua en el contenido radiactivo: analisis en plantas purificadoras a pequena escala  

Energy Technology Data Exchange (ETDEWEB)

Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was ...

2009-10-15

178

Rotor-stator and disc systems for emulsification processes  

Energy Technology Data Exchange (ETDEWEB)

Emulsions now find a wide range of applications in industry and daily life. In the pharmaceutical industry lipophilic active ingredients as well as many nutritional products such as vitamins are often formulated in the dispersed phase of oil-in-water emulsions. Emulsions can be produced with different mechanical emulsification techniques. In the following review, the process of rotor-stator systems and disc systems are compared to other popular mechanical emulsification systems. On the basis of experimental results from the authors' laboratory, a discontinuous gear-rim dispersing system, discontinuous disc system, and a continuous high pressure system are compared with regard to their attainable mean droplet diameter and drop size distribution in an oil-in-water emulsion. It can be shown that dissolver discs ...

2006-01-01

179

Measurement of oxidation rate of sulfite in rain water in Yokohama, Japan  

Energy Technology Data Exchange (ETDEWEB)

In recent years, the influences of acid rain such as the acidification of lake water, on bio-system by the heavy metals from effluent of soils with acid rain and also on the structural materials of buildings are seriously discussed. Sulfur and nitrogen that are contained in fossil fuels are released into the atmosphere by the fuel combustion as their oxides dissolve in rain drops as sulfite and nitrous ions, where they are further oxidized into sulfate and nitrate ions These ions lower the pH of rain water resulting so-called acid rain. Therefore, it is important to accurately determine these ions in rain water for the investigation of reality of acid rain. However, it is not easy to accurately determine these ions, especially for sulfite ions in rain water, since they are quickly oxidized by the catalytic action of metallic ions such as ferric and manganous ions. And light, ...

1986-04-01

180

Improved primary water chemistry control of PWR plant in Japan  

International Nuclear Information System (INIS)

Elevated pH operation to the pH value of 7.3 at 285degC is known to be effective for the reduction of radiation source in the primary water system of PWRs. A research project was started in 1989 and concluded in 1996 to study and verify the optimum pH and/or Li concentration from the viewpoint of radiation source reduction and materials integrity under improved water chemistry. This research project is sponsored by the Ministry of International Trade and Industries (MITI) in Japan and has two programs; high pH and high Li. The high Li program was conducted to establish the optimum Li concentration for the high boron concentration region (1100 - 1800 ppm) of the high burn up operation. In this paper, we shall discuss radiation source behavior under high pH conditions and PWSCC (Primary Water Stress Corrosion Cracking) susceptibility of materials with change of primary water chemistry ...

1998-04-01

181

Effect of water activity on the lipase catalyzed esterification of geraniol in ionic liquid [bmim]PF6.  

Science.gov (United States)

Enzymatic reactions in non-aqueous media have been shown to be effective in carrying out chemical transformation where the reactants are insoluble in water or water is a byproduct limiting conversion. Ionic liquids, liquid organic salts with infinitesimal vapor pressure, are potentially useful alternatives to organic solvents. It is known that the thermodynamic water activity is an important variable affecting the activity of enzymes in non-aqueous solvents. This study investigated the influence of water activity on the esterification of geraniol with acetic acid in ionic liquid [bmim]PF6 catalyzed by immobilized Candida antarctica lipase B. The conversion of geraniol in [bmim]PF6 was significant although the reaction rate was slower than in organic solvents. The profile of initial reaction rate-water activity was determined experimentally, and differed from the data reported for ...

2006-02-01

182

Development of cast-in-place concrete pile installation technique for application in the presence of artesian water; Hiatsu chikasui kasho ni okeru bashouchi kui sekoho no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

When a rotary excavator is operated at locations where there is artesian water, the aquiclude is fractured under pressure of the artesian water upon the penetration of the pile tip through the aquiclude. Since the equipment is provided with a gap for the reduction of friction between the casing and the excavation face, soil and sand near the pile tip burst forth out of the ground together with underground water through the casing or along the outer circumference of the casing. The newly contrived method introduced here is a double pipe process, in which a large casing (2.0m in diameter) is driven until it lands on the aquiclude, water is injected into the casing for the creation of equilibrium between the artesian head and the head in the casing, and finally a casing as large as the pile (1m in diameter) to be installed is used for the excavation of the artesian water section. Since ...

1998-11-05

183

Analytical surveys on water quality of Trasimeno Lake: Definition of trophic levels; Indagine sulla qualita` delle acque del Lago Trasimeno: Definizione dei livelli trofici  

Energy Technology Data Exchange (ETDEWEB)

The previous judgment of eutrophic state, once proposed for the Trasimeno Lake (Umbria region, Italy), has been revised. According to Vollenweider-OECD classification criterion, the lake waters are at present to be classified as mesotrophic waters, with phosphorus limitation. However this level of moderate productivity results to be conditioned by the hydrochemical characteristics of the lake waters, that control phosphorus concentrations independently from the loading coming from the basin, and prevent dangerous and massive algal blooms. Different processes of chemical nature, regulating the phosphorus amount in the lake waters, are then reviewed: adsorption of P/P0(4) onto suspended materials, particularly clay mineral particles, and direct precipitation as hydroxylapatite or co-precipitation with carbonates, are found to be the principal mechanisms that determine chemical removal of phosphorus from ...

1995-06-01

184

Safety System Design Concept and Performance Evaluation for a Long Operating Cycle Simplified Boiling Water Reactor  

Science.gov (United States)

The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between the inner and outer ...

2003-07-15

185

High performance fiber filtration and its fluid flow  

Energy Technology Data Exchange (ETDEWEB)

A new filtration process using acrylic fiber has been developed which has wide applications in water works, sewage water treatment and waste water treatment facilities. Instead of sand, the common filter media in conventional systems, this new system uses long, fine acrylic fibers. Compared with a conventional system, the filtration speed and suspended solids (SS) retention of the new system have been increased 500% from 120--200 m/d to 400--1,200 m/d and from 2--3 kg/m{sup 2} to 5--20 kg/m{sup 2}, respectively. In addition, the backwash time has been decreased 60%, from 20--30 min to 10 min. As SS retention increase, the empty space between the fibers (fiber void) decreases and pressure drops due to the high filtration rate. Thus the pressure decreases rapidly after a certain period of filtration because of the increased SS retention cause ...

1994-12-31

186

Back-up for high voltage cable pressurizing system  

Energy Technology Data Exchange (ETDEWEB)

A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.

1982-07-19

187

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

188

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

189

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

190

Recovery of Water from Boiler Flue Gas  

Energy Technology Data Exchange (ETDEWEB)

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both ...

2008-09-30

191

Management and optimization of the CPCU network working  

Energy Technology Data Exchange (ETDEWEB)

The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for the establishing management data in real ...

1991-10-01

192

Contingency interim measure for the public water supply at Barnes, Kansas.  

Energy Technology Data Exchange (ETDEWEB)

This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public ...

2009-07-09

193

An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)  

International Nuclear Information System (INIS)

Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 ...

2007-11-07

194

Revegetation of inactive U-tailing sites  

International Nuclear Information System (INIS)

Soil placed over any sealant/barrier system can provide a protective mantle if the soil is not lost by erosion. Vegetation is an attractive choice for controlling erosion because it can provide an economical self-renewing cover that serves to reduce erosion by both wind and water. The objective of this research and development effort is to select and test vegetation strategies, including the choice of species and methods for revegetation that are compatible with sealant/barrier systems and are suited to soils and climates at inactive uranium mill tailings sites.

1981-02-01

195

Reductive dechlorination of chlorinated solvents by zero-valent iron, iron oxide and iron sulfide minerals  

Energy Technology Data Exchange (ETDEWEB)

The degradation of chlorinated solvents by reduction at the surface of zero-valent metals and bimetallic systems has emerged as an important approach to the in-situ remediation of ground water. Reduction by iron metal was studied in batch and column systems to develop a mechanistic understanding of the reaction chemistry and to determine the factors that affect dechlorination rate and long term performance in field applications.

1996-10-01

196

Radisson community heating systems: technical and economic comparison of options. Final report  

Energy Technology Data Exchange (ETDEWEB)

The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.

1981-12-01

197

Floating production and storage vessels - design analysis and operational issues: a handbook produced to accompany the Bentham Technical Training Courses  

Energy Technology Data Exchange (ETDEWEB)

These ten chapters present an overview of floating production, storage and offloading (FPSO) vessels, and examines deep water developments; hydrostatic stability; production, storage and offloading systems; the configuration and structure of flexible risers and umbilicals; the structural and global dynamic analysis of flexible riser and umbilicals; verification of FPSO structural integrity; vessel global loading and rigid body response; environmental loading and vessel response; and mooring systems. (UK)

1998-07-01

198

Application of river basin simulation for flood hazard assessment  

Energy Technology Data Exchange (ETDEWEB)

2D simulation modeling of a river basin is based on notion of a River Basin as an opened non equilibrium nature system. All components of the system (elevation, water, soil properties and others) are linked to single multi - functional model. The objective of flood simulation is one the model functions. The objectives of the paper are as follows: a mean scale basin floods computing and the model validation; a large scale basin simulation and demands for its validation; results and demands for flood hazard assessment. (orig.)

2000-07-01

199

Analysis of chlorinated polyvinyl chloride pipe burst problems :Vasquez residence system inspection.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.

2005-10-01

200

The PANDA facility and first test results  

International Nuclear Information System (INIS)

The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (orig.).

201

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

202

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

203

Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water  

International Nuclear Information System (INIS)

Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).

2010-01-15

204

Cloud-point measurement for (sulphate salts + polyethylene glycol 15000 + water) systems by the particle counting method  

International Nuclear Information System (INIS)

The phase separation of (water + salt + polyethylene glycol 15000) systems was studied by cloud-point measurements using the particle counting method. The effect of three kinds of sulphate salt (Na2SO4, K2SO4, (NH4)2SO4) concentration, polyethylene glycol 15000 concentration, mass ratio of polymer to salt on the cloud-point temperature of these systems have been investigated. The results obtained indicate that the cloud-point temperatures decrease linearly with increase in polyethylene glycol concentrations for different salts. Also, the cloud points decrease with an increase in mass ratio of salt to polymer.

2009-07-01

205

Adaptations of the Purge Water Management System for Long-Term Groundwater Monitoring at Savannah River Site, South Carolina (final)  

Energy Technology Data Exchange (ETDEWEB)

To monitor the groundwater contamination and the effectiveness of remedial actions, over a thousand monitoring wells are in active operation (i.e., require quarterly or semi-annual sampling) at SRS. Most wells are expected to continue in operation for another 20 to 40 more years. Required sample volumes can range from a less than a liter to 10 liters. To support the long-term groundwater monitoring requirements of these wells, SRS actively seeks technologies that can maximize data acquisition and minimize costs. To meet this end, SRS has implemented the Purge Water Management System (PWMS). The key attributes of this system lie in its ability to reduce or eliminate the generation of purged groundwater, which is costly in terms of the time and management.

2004-02-10

206

Deliberate ignition of hydrogen-air-steam mixtures in condensing steam environments  

Energy Technology Data Exchange (ETDEWEB)

Large scale experiments were performed to determine the effectiveness of thermal glow plug igniters to burn hydrogen in a condensing steam environment due to the presence of water sprays. The experiments were designed to determine if a detonation or accelerated flame could occur in a hydrogen-air-steam mixture which was initially nonflammable due to steam dilution but was rendered flammable by rapid steam condensation due to water sprays. Eleven Hydrogen Igniter Tests were conducted in the test vessel. The vessel was instrumented with pressure transducers, thermocouple rakes, gas grab sample bottles, hydrogen microsensors, and cameras. The vessel contained two prototypic engineered systems: (1) a deliberate hydrogen ignition system and (2) a water spray system. Experiments were conducted under conditions scaled to be nearly prototypic of those expected in ...

1997-05-01

207

Wax and hydrate control with electrical power  

Energy Technology Data Exchange (ETDEWEB)

Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the ...

1997-08-01

208

Soil less culture; I sistemi di coltivazione senza suolo  

Energy Technology Data Exchange (ETDEWEB)

The paper gives a general view of techniques and systems related to soil less culture developed in the last years (on substrate in beg; NFT; Ebb-Flood, aeroponic,..) taking into account their management and problems (water quality, control of plant nutrition and irrigation; substrates; pathological aspects,..). The evolution, now in progress, of soil less culture from open to closed system as a way to realized an environmental friendly growing system, is considered. When plants are grown with open cycle techniques a large amount of waste solution, with an a high content of nutrients, are discharged in soil and water. Furthermore, they need an extra-utilization of water and fertilizers. Another aspect is the utilization of low cost substrates, which can be reused for more than one cultural cycle without negative effects on yield, and also finally discharged ...

1996-01-01

209

Economic analysis for utilization of geothermal energy by North Dakota Concrete Products Co.  

Energy Technology Data Exchange (ETDEWEB)

North Dakota Concrete Products Company uses a steam curing process that accelerates the concrete curing so that 28-day strength is obtained within 24 hours. The cost of energy required to accomplish this is significant, amounting to approximately $80,000 in 1980. The present boilers are oil fired. Recently, fuel oil prices have increased substantially. Further, supply shortages in the past have threatened plant production. The purpose of this study was to evaluate the economic feasibility of using deep formation warm water as an alternative energy source. A water-to-water heat pump system to replace the existing boiler system was investigated. TPI, Inc. economic and engineering findings for this particular potential geothermal application are disclosed. The operating cost savings of the geothermal system over the operating costs of the existing oilfired system ...

1982-02-01

210

Low-head air stripper treats oil tanker ballast water  

Energy Technology Data Exchange (ETDEWEB)

Prototype tests conducted during the winter of 1989/90 have successfully demonstrated an economical design for air stripping volatile hydrocarbons from oily tanker ballast water. The prototype air stripper, developed for Alyeska's Ballast Water Treatment (BWT) facility in Valdez, Alaska, ran continuously for three months with an average removal of 88% of the incoming volatile organics. Initially designed to remove oil and grease compounds from tanker ballast water, the BWT system has been upgraded to a three-step process to comply with new, stringent regulations. The BWT biological oxidation process enhances the growth of bacteria present in the incoming ballast water through nutrient addition, aeration, and recirculation within a complete-mixed bioreactor. The average removal of BETX is over 95%, however, occassional upsets required the placement of a polishing air ...

1992-02-01

211

Geophysical remote sensing of water reservoirs suitable for desalinization.  

Energy Technology Data Exchange (ETDEWEB)

In many parts of the United States, as well as other regions of the world, competing demands for fresh water or water suitable for desalination are outstripping sustainable supplies. In these areas, new water supplies are necessary to sustain economic development and agricultural uses, as well as support expanding populations, particularly in the Southwestern United States. Increasing the supply of water will more than likely come through desalinization of water reservoirs that are not suitable for present use. Surface-deployed seismic and electromagnetic (EM) methods have the potential for addressing these critical issues within large volumes of an aquifer at a lower cost than drilling and sampling. However, for detailed analysis of the water quality, some sampling utilizing boreholes would be required with geophysical methods being employed to extrapolate ...

2009-12-01

212

A field demonstration of the microbial treatment of sour produced water  

Energy Technology Data Exchange (ETDEWEB)

The potential for detoxification and deodorization of sulfide-laden water (sour water) by microbial treatment was evaluated at a petroleum production site under field conditions. A sulfide-tolerant strain of the chemautotroph and facultative anaerobe, Thiobacillus denitrificans, was introduced into an oil-skimming pit of the Amoco Production Company LACT 10 Unit of the Salt Creek Field, Wyoming. Field-produced water enters this pit from the oil/water separation treatment train at an average flowrate of 5,000 bbl/D (795 m{sup 3}/D) with a potential maximum of 98,000 bbl/D (15,580 m{sup 3}/D). Water conditions at the pit inlet are 4,800 mg/l TDS, 100 mg/l sulfide, pH 7.8, and 107{degrees}F. To this water an aqueous solution of ammonium nitrate and diphosphorous pentoxide was added to provide required nutrients for the bacteria. The first 20% of the pit was aerated ...

1995-12-31

213

Water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation demonstration site in Fort Worth, Texas, 1996-2003  

Science.gov (United States)

In 1996, a field-scale phytoremediation demonstration project was initiated and managed by the U.S. Air Force at a site in western Fort Worth, Texas, using a plantation of 1-year-old stems harvested from branches of eastern cottonwoods during the dormant season (whips) and a plantation of 1-year-old eastern cottonwood seedlings (calipers). The primary objective of the demonstration project was to determine the effectiveness of eastern cottonwoods at reducing the mass of dissolved trichloroethene transported within an alluvial aquifer. The U.S. Geological Survey conducted a study, in cooperation with the U.S. Air Force, to determine water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation site. As part of the study, water-level and water-quality data were collected throughout the duration of the project. This report presents ...

2004-01-01

214

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28

215

The cascade of reservoirs of the ``Mayak`` Plant: Case history and the first version of a computer simulator  

Energy Technology Data Exchange (ETDEWEB)

The improvement of the ecological conditions at waste storing reservoirs is an important task of the restoration activity at Production Association (PA) ``Mayak`` (South Urals). The radionuclides mostly {sup 90}Sr, {sup 137}Cs, and chemical pollutants deposited in the reservoir water and in the bottom sediment are very dangerous sources for the contamination of Techa River below the reservoirs and the contamination of groundwater in the surrounding formations. The spreading of radioactive contaminants has both hydrogeological and the chemical features. The thermodynamic approach used to account for physical-chemical interactions between water and the bed rocks based on Gibbs free energy minimization of multicomponent system (H-O-Ca-Mg-K-Na-S-Cl-C-Sr) permitted the authors to calculate the corresponding ionic and complex species existing in the solutions, and to characterize the processes of precipitation and dissolution. ...

1994-07-01

216

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the secondary ...

2009-02-01

217

Effect of Suburban Development and Landscape Position on Water Quality in Three Small Watersheds Within the Croton System, New York.  

Science.gov (United States)

Internal hydrological processes in suburban watersheds and their effects on water quality warrant investigation. Instrument clusters (throughfall collectors, suction lysimeters, monitoring wells, and shallow and deep piezometers) were installed at several locations within three small (50 - 70 ha) watersheds (one forested, two with different degrees of suburban development) in the Croton Watershed, southeastern New York. Biweekly and storm samples were analyzed for base cations, selected anions, and DOC over a one-year period. The topographic index (TI) quantified landscape position; flowpath analyses determined degree of development at each cluster, using % impervious cover as the metric. Water quality degradation was observed in sites with medium and high TI values; no such effect was observed along the ridges, i.e., low TI values. At medium TI values, areas with more than 5% impervious had degraded water quality. At high ...

2003-12-01

218

Crud removal performance with ion exchange resins in BWR plants  

Energy Technology Data Exchange (ETDEWEB)

It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud ...

1996-01-01

219

The potential of solar-driven humidification-dehumidification desalination for small-scale decentralized water production  

Energy Technology Data Exchange (ETDEWEB)

World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating is compared to direct ...

2010-05-15

220

Removal and recovery system of hexavalent chromium from waste water by tannin gel particles  

Energy Technology Data Exchange (ETDEWEB)

Tannin gel particles that have extremely high adsorption capacity for hexavalent chromium Cr(VI) have been developed by controlling gelation of Mimosa tannin extracted from the bark of plants. The gelation process is composed of two stages; partial gelation of Mimosa tannin by reaction with formaldehyde (cross-linking agent) and granulation by dispersing the partially gelated solution into a liquid mixture of decalin ad a polyether nonionic surfactant with vigorous stirring. The structure of the tannin gel particles is controlled by a combination of operating conditions such as reaction time and temperature at both stages. The water content of the tannin gel particles that reflects their structure can be widely changed from 40 to 79 %(wet basis), even for a constant composition of 23 g Mimosa tannin and 6 ml formaldehyde (37 wt %). It is found that it is very important to increase the water content without losing mechanical strength and supply ...

2000-10-01

221

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be ...

1998-11-15

222

Development and field application of a leak sealant for the NRU water reflector  

International Nuclear Information System (INIS)

The development and successful application of a unique leak sealant formulation comprised of a mixture of graded, hollow ceramic microspheres, surface oxidized aluminum powder and saturated gibbsite suspension is described. The project was undertaken to address the escalating leakage from up to 15 small weld defects in the water reflector vessel, an integral component of the NRU (National Research Universal) reactor calandria. The reflector surrounds the reactor core with a neutron reflecting blanket of light water. Injection of the sealant is typically done with the reactor shutdown and the water reflector system operating normally, but can also be performed with the reactor at full power. The procedure is simple and effective. Individual treatments of as little as 125 ml of sealant (10 ppm in the 12,500 L system) have yielded leak reductions exceeding 2000 L/day. The accumulated ...

2001-06-10

223

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport ...

2006-11-13

224

Thermal-hydraulic testing on a Mitsubishi simplified PWR  

Energy Technology Data Exchange (ETDEWEB)

Mitsubishi is now developing a new Pressurized water reactor (PWR), the Mitsubishi simplified PWR (MS-PWR), which has the innovative features of hybrid safety systems (an optimum combination of passive and active systems) and cooling by horizontal steam generators. In order to confirm the feasibility of the Mitsubishi hybrid safety system, various kinds of safety analyses are performed for loss-of-coolant accident events. In parallel to these safety analysis efforts, the following thermal-hydraulic tests are to be performed: (1) thermal-hydraulic test of a horizontal steam generator; (2) integrated thermal-hydraulic test using a simulation loop for the innovative MS-PWR (SLIM).

1993-01-01

225

Standardization/improvement and technical development of light water reactor power station in Japan(BWR)  

Energy Technology Data Exchange (ETDEWEB)

In order to realize improve of reliability and economy by duplicate production, rapid supply of repair parts from standardized storage, such were expected as to have continuous order of standardized plant, to ignore site condition, to avoid expansion of regulatory requirement. Standardization program was planned to limitedly promote standardization of safety-related design concept, major specification and basic system composition of reactor and primary systems. The area of standardization had been tried to expand to BOP such as general arrangement and rad-waste system.

1985-07-01

226

Remote monitoring of a coal waste impoundment in West Virginia. Open file report Oct 78-Sep 81  

Energy Technology Data Exchange (ETDEWEB)

This report addresses remote monitoring of coal waste impoundments for stability. Existing automated geotechnical monitoring systems are described and reviewed along with details of instruments suitable for such systems. An impoundment in West Virginia, which was in the construction stage, was instrumented and monitored between July 1979 and May 1981. Sensors that measure surface and subsurface parameters including settlement, horizontal deflection, surface tilt, pore water pressure, seepage, pond level, and meteorlogical parameters were installed. Recommendations for improving and expanding the capabilities of the monitoring system are given.

1982-02-01

227

Proceedings of the Canadian Society for Bioengineering CSBE/SCGAB 2008 annual meeting  

Energy Technology Data Exchange (ETDEWEB)

This conference provided a forum to discuss advances in the application of bioengineering principles and practices dealing with biological systems for the production of food, bioproducts and energy. The topics of discussion ranged from engineering practices in agriculture, forestry, bioresources, biochemistry and biosystems. The sessions of the conference were entitled: renewable energy; waste management; soil and water; machinery systems; building and storage systems; and bioproducts and food. The conference also featured a workshop on integrated biomass supply and logistics. In addition to 20 posters, the conference featured 67 presentations, of which 3 have been catalogued separately for inclusion in this database. refs., tabs., figs.

2008-07-01

228

Comparison of fuzzy control systems for hypothermal brain temperature regulation  

British Library Electronic Table of Contents (United Kingdom)

The automatic control system for brain tissue temperature is studied theoretically for brain hypothermia treatment. In order to realize a human-friendly control mechanism, an automatic temperature regulation system is constructed to simulate brain hypothermia treatment by introducing a fuzzy algorithm for possible characteristic changes in patients. The brain temperature model is successfully realized to follow the desired temperature course automatically. The model reference fuzzy control of brain temperature based on water-cooling blankets is verified for clinical application to brain hypothermia treatments through various kinds of simulation experiment.

2007-01-01

229

Real-time neutron radiography at McMaster  

International Nuclear Information System (INIS)

The McMaster Neutron Radiography Facility (MNRF) is fortunate to own the only Real-Time Neutron Radiography system in Canada. Current research at the MNRF involves the visualization of gas-liquid and gas-solid two-phase flow in complex channels, such as nuclear fuel channels, using light water, heavy water, freon-134A, slurries, and other fluids. Other research at the MNRF has examined single-phase flow, material purity, film deposition, turbine blades, and automotive parts.

1995-01-01

230

Leak sealing on ancillary cooling circuits of CANDU reactors  

International Nuclear Information System (INIS)

This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.

1992-11-22

231

Hot water from the sun; Increasing awareness of energy saving considerations - thermal solar systems booming. Heisses Wasser von der Sonne; Umweltbewusster Umgang mit Energieressourcen findet immer mehr Anhaenger - Boom fuer thermische Solarsysteme  

Energy Technology Data Exchange (ETDEWEB)

Thermal solar energy plants for water heating have experienced an enormous boom during the last years. Thus, a total of 200000 square metres of collector surface was installed on German rooves in 1991. This was three times as much as in the year before. And this trend of conserving natural resources by using the energy of the sun is still undiminished. (orig.)

1993-11-01

232

Electrical conductivity of radiation-processed wood polymer composites  

International Nuclear Information System (INIS)

Two species of wood, viz. Haldu (Adina Cordifolia) and Jamun (Syzygium Cumini) were vacuum-impregnated with two styrene-based monomer systems and polymerized in situ with gamma radiation from a cobalt-60 source. The electrical conductivity of these specimens was determined at various polymer loadings under dry conditions, after wetting and after wet recovery as per ASTM standards. The water absorption characteristics are also presented. The results are discussed with special reference to the role of water. Potential applications are also discussed. 7 figures.

1978-01-01

233

Conception and design of steam power plants  

International Nuclear Information System (INIS)

The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).

234

Turn-key Raman lidar for profiling atmospheric water vapor, clouds, and aerosols at the US Southern Great Plains Climate Study Site  

Energy Technology Data Exchange (ETDEWEB)

There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for particle phase studies.

1997-12-31

235

On the development of a new methodology for groundwater-driven health risk assessment  

Science.gov (United States)

A methodology and hypothetical case study are presented for incorporation of uncertainty and variability into calculations of human health risk appropriate for regional, or basin-scale, groundwater management problems. Uncertainty in well water concentration is introduced through complex contaminant migration patterns in the subsurface. Variability is considered in parameters related to individual behavior patterns and biological effects and to groundwater extraction and distribution networks. A joint uncertainty and variability (JUV) analysis is used to generate a two-dimensional distribution or risk surface that spans both transport uncertainty as well as individual variability. Cuts in this distributional surface (fractiles of variability and percentiles of uncertainty) are presented and discussed. Comparisons with alternative approaches based upon deterministic transport models are also made. In addition, important distinctions are made between the case where ...

1998-01-01

236

Improvement of lake water quality by paying farmers to abate nonpoint source pollution. Research report  

Energy Technology Data Exchange (ETDEWEB)

To mitigate damages caused by agricultural runoff, private lake owners' associations are paying for inlake and instream pollution abatement measures and on land-conservation practices. This phenomenon supports the notion that individuals who benefit from improved water quality should be willing to pay part of the abatement costs. The research suggests that on land-conservation measures can substantially reduce sediment delivery at low cost. The Sediment Economics (SEDEC) model was modified and then used to select and to site management systems that achieved stated sediment goals at least cost. Other resource policies such as T value, no-till, and contouring were compared with the least-cost frontier and shown to be more costly. The noncropland areas substantially reduced sediment delivery to water channels and lowered abatement costs. Further research is needed for long-range watershed-planning models such as ...

1988-12-01

237

Existing systems review of treatment media for the Bear Creek Valley treatability study, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

In situ treatment has been proposed as a remediation alternative for surface water and groundwater contaminated with uranium and nitrate as a result of former waste disposal practices in the S-3 Ponds. Interceptor trenches containing reactive media have been proposed to treat groundwater, and constructed wetlands and/or algal mats are potential alternatives for treating surface water. This report presents the results from testing of ten different reactive media, and combinations of media, that are candidates for use in the proposed interceptor trenches to remove uranium and nitrate from groundwater. It also presents the results of testing and evaluation of algal mats and wetlands for removing uranium and nitrate from surface water.

1998-01-01

238

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve ...

239

Dynamic Adjustment of Irrigation Technology/Water Management in Western U.S. Agriculture: Toward a Sustainable Future  

British Library Electronic Table of Contents (United Kingdom)

Changing water demands induced through climate change and a growing biofuel energy sector throughout the western States are expected to increase pressures on the present allocation mechanisms for an increasingly scarce resource, raising uncertainty about the sustainability of irrigated agriculture in the West. In this paper, we first present the policy motivation for examining continued producer adoption of water conserving irrigation production systems as a foundation for providing a sustainable future for western irrigated agriculture. Second, we summarize the historical transitions that help to define the adjustment path to increased sustainability for the sector. While western irrigated agriculture is on a path toward greater sustainability, evidence suggests that the sustainability go...

2010-01-01

240

Device for controlling feedwater at low power of nuclear power plants  

International Nuclear Information System (INIS)

Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum level can be minimized. (Seki, T.).

241

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

242

Study on core cooling of hybrid safety system for next-generation PWR during LOCA  

International Nuclear Information System (INIS)

Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of ...

1995-04-23

243

Upper Paleozoic petroleum system, Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The Ordos Basin is a typical lapped basin, including three sequences of strata: early Paleozoic, late Paleozoic and Mesozoic, with a total thickness of 4000-6000m. Impermeable sealing beds are well developed at the top and base of the upper Paleozoic sequence, separating it from the Mesozoic and the lower Paleozoic strata to form an independent petroleum system. In this petroleum system, the source rocks are widely distributed coals and dark mudstones occurring in the Carboniferous-lower Permian coal measures, with a thickness of 10-15 and 40-60m, respectively. The reservoirs are mainly early Permian tight sandstones, mostly with a porosity of 4-8% and a permeability of 0.1-1.0x10{sup -3}{mu}m{sup 2}. The regional cap rock is a 100-150m thick mudstone in the upper Permian strata. The structural framework of the basin is a huge asymmetric syncline, dipping gently toward the east and north, and steeply toward the south and west. Well data show ...

2005-09-01

244

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...

2011-01-01

245

New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.

1997-12-01

246

MINERGIE modules: heat pump - heat pump/solar - wood - wood/solar; Minergie-Module Waermepumpe - Waermepumpe/Solar - Holz - Holz/Solar  

Energy Technology Data Exchange (ETDEWEB)

This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions ...

2005-07-01

247

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in ...

2008-11-19

248

Nuclear desalination for the petrochemical complex of the Natuna project  

International Nuclear Information System (INIS)

On the basis of environmental considerations, a high temperature gas cooled reactor (HTGR) was proposed as the heat source for the Natuna project for CO_2 conversion. To convert CO_2 to useful products, a large amount of high quality water is required for the chemical processes, boilers and other purposes. One LNG production train (maximum of six trains) would produce 0.4 x 10"9 SCF/d of saleable gas and 1.4 x 10"9 SCF/d of CO_2 (in the case of the Exxon process). This CO_2 gas would then be converted to automobile fuel (methane, methanol), which requires a large amount of water. Natural gas from an off- shore gas field is piped to the petrochemical complex on Natuna Island (about 228 km). Natuna is a small island that, apart from sea water, does not have much available water. The desalination process is considered to be the only solution to the water demand problems of the ...

1997-12-01

249

Contaminant assimilation in newly created prairie wetlands  

Energy Technology Data Exchange (ETDEWEB)

Increased use of wetlands for habitat and water quality improvement emphasize the need for further study of abiotic-biotic interactions in these systems. This research examined contaminant assimilation within the water column of two newly created Colorado prairie wetlands (RMA3 and RMA4). To examine the influence of abiotic factors (e.g., alkalinity, suspended solids), ten chronic toxicity tests were performed from December 1991 through November 1993. In the first set of tests, Ceriodaphnia dubia were exposed to water from the two wetlands which was spiked with various concentrations of zinc. These tests suggested that water from RMA4 had higher contaminant assimilative capacity than water from RMA3. Preliminary analysis suggested suspended solids, pH, conductivity, and temperature were important factors affecting neonate production by C. dubia when exposed to ...

1994-12-31

250

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ranged from 49% to 60% of the incident solar energy. The ...

1979-01-01

251

New analytical technique for carbon dioxide absorption solvents  

Energy Technology Data Exchange (ETDEWEB)

The densities and refractive indices of two binary systems (water + MEA and water + MDEA) and three ternary systems (water + MEA + CO{sub 2}, water + MDEA + CO{sub 2}, and water + MEA + MDEA) used for carbon dioxide (CO{sub 2}) capture were measured over the range of compositions of the aqueous alkanolamine(s) used for CO{sub 2} absorption at temperatures from 295 to 338 K. Experimental densities were modeled empirically, while the experimental refractive indices were modeled using well-established models from the known values of their pure-component densities and refractive indices. The density and Gladstone-Dale refractive index models were then used to obtain the compositions of unknown samples of the binary and ternary systems by simultaneous solution of the density and refractive index equations. The results from ...

2008-02-15

252

Integrated interpretation of AE clusters and fracture system in Hijiori HDR artificial reservoir; Hijiori koon gantai jinko choryuso no AE cluster to kiretsu system ni kansuru togoteki kaishaku  

Energy Technology Data Exchange (ETDEWEB)

With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heat exchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized ...

1997-05-27

253

Explosion confinement system for exploitations by sublevels; Sistema de Confinamiento de Explosiones para Explotaciones por Subniveles  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to develop a explosion suppression system capable to confine and extinguish gas explosions of the type produced in sub level caving faces when blasting to the coal pillar. Existing systems, such as triggered barriers, were considered not to be valid because of size, weight, cost, and other operational constraints. The research activities have been focused in the development of a mixed water/air spray system that should be manually activated some second before blasting. Two prototypes have been developed and tested, the first one using nozzle operating at the standard ranges of pressure that are normally available in underground coal mines, and a second one based in high-pressure nozzles. In this case, bottles containing a pressurized air/water mixtures are required. The works carried out included theoretical studies, hydraulic nozzles ...

1999-11-01

254

Effective multiplication factor measurement by feynman-{alpha} method. 3  

Energy Technology Data Exchange (ETDEWEB)

The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and ...

1998-06-01

255

Snow Survey & Water Supply | NRCS  

Science.gov (United States)

Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...

2011-08-21

256

Reconsidering the site requirements for NPP on Olt River  

International Nuclear Information System (INIS)

Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling ...

2009-10-12

257

Spent fuel consolidation in the 105KW Building fuel storage basin  

Energy Technology Data Exchange (ETDEWEB)

This study is one element of a larger engineering study effort by WHC to examine the feasibility of irradiated fuel and sludge consolidation in the KW Basin in response to TPA Milestone (target date) M-34-00-T03. The study concludes that up to 11,500 fuel storage canisters could be accommodated in the KW Basin with modifications. These modifications would include provisions for multi-tiered canister storage involving the fabrication and installation of new storage racks and installation of additional decay heat removal systems for control of basin water temperature. The ability of existing systems to control radionuclide concentrations in the basin water is examined. The study discusses requirements for spent nuclear fuel inventory given the proposed multi-tiered storage arrangement, the impact of the consolidated mass on the KW Basin structure, and criticality issues associated with multi-tiered ...

1994-09-23

258

Pulse radiolysis studies on [Fe(CN)_6]"4"- - BrO_3"- - CN"-system in ethylene glycol - water solutions  

International Nuclear Information System (INIS)

Formation of oxidizing and reducing radicals was studied by pulse radiolysis of [Fe(CN)_6]"4"- - BrO_3"- - CN"- system in ethylene glycol - water solvent mixture. Oxidizing #centre dot#BrO_2 and BrO radicals formed by electron scavenging with #centre dot#BrO_2"- were identified and their reactions were investigated. The reaction of hydroxyl radicals with ethylene glycol leads to formation of reactive radicals with reducing properties and of compounds which reduce slowly in dark the ferricyanide formed in the reaction of #centre dot#BrO_2 radical with ferrocyanide. (author) 21 refs.; 7 figs.

1991-01-01

259

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through the CANDU flux ...

1992-01-01

260

Investigation of erosion-corrosion of 3003 aluminum alloy in ethylene glycol-water solution by impingement jet system  

British Library Electronic Table of Contents (United Kingdom)

Erosion-corrosion (E-C) of 3003 aluminum (Al) alloy in ethylene glycol-water solutions were studied by weight-loss and electrochemical measurements as well as surface characterization through an impingement jet system. Al alloy E-C is dominated by erosion components, i.e., pure erosion and corrosion-enhanced erosion, which account for 92-97% of the total E-C rate under the various conditions in this work. Contribution from corrosion components, including pure corrosion and erosion-enhanced corrosion, is slight. With the increase of fluid flow velocity and sand concentration, the total E-C rate increases. Compared with the significant increase of the rates of erosion components, the increase of the rate of corrosion component is negligible. Upon fluid flow, passivity of Al alloy that develo...

2009-01-01

261

Interaction of periodic and iodic acids with propyoneamide in aqueous solutions  

International Nuclear Information System (INIS)

Interaction of periodic and iodic acids with propyoneamide in aqueous solutions at 25 deg C has been studied. In the system iodic acid-propyoneamide-water formation of two compounds of the composition 6C_2H_5CONH_2#centre dot#HIO_3 and C_5H_5CONH_2#centre dot#HIO_3 is ascertained, for which concentrational boundaries of formation, density, melting points are determined. The system periodic acid-propyoneamide-water is referred to the simple eutonic type. By the method of IR spectroscopy it has been shown that oxygen atom of amide carbonyl group is the centre of propyoneamide protonation by iodic acid.

262

Functional changes of the visual system of the damselfish Dascyllus marginatus along its bathymetric range  

British Library Electronic Table of Contents (United Kingdom)

Shallow-water zooplanktivorous fish rely on their vision for foraging. In shallow water, feeding efficiency decreases in dim light and thus the fish cease foraging at crepuscular hours. Creatures living in the lower parts of their depth ranges are expected to be exposed to limited light levels for longer hours. However, observations of the zooplanktivore Dascyllus marginatus showed little change in foraging duration down to 40m deep. We asked whether the visual system's functionality changes with depth along the depth range of this damselfish; we examined eye and retina anatomy for changes in visual acuity and light sensitivity and used the optomotor response to test for spatial and temporal light summation. We found only minor changes in the anatomy of the eye that are not expected to aff...

2010-01-01

263

A hybrid solar desalination process of the multi-effect humidification dehumidification and basin-type unit  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a hybrid solar desalination process of the multi-effect humidification dehumidification and the basin-type unit. The sketch of the hybrid solar desalination process is given. The solar vacuated tube collector is employed in the desalination system, multi-effect humidification dehumidification desalination (HDD) process is plotted according to pinch technology, and then the water rejected from multi-effect HDD process is reused to desalinate in a basin-type unit further. The gain output ratio (GOR) of this system will rise by 2?3 at least through reusing the rejected water. The research proves that the multi-effect HDD has much room to be improved. A hybrid solar desalination process of the multi-effect humidification dehumidification and the basin-type unit should be no...

2008-01-01

264

Profile extrusion of wood plastic cellular composites and formulation evaluation using compression molding  

Science.gov (United States)

Wood Plastic Composites (WPCs) have experienced a healthy growth during the last decade. However, improvement in properties is necessary to increase their utility for structural applications. The toughness of WPCs can be improved by creating a fine cellular structure while reducing the density. Extrusion processing is one of the most economical methods for profile formation. For our study, rectangular profiles were extruded using a twin-screw extrusion system with different grades of HDPE and with varying wood fibre and lubricant contents together with maleated polyethylene (MAPE) coupling agent to investigate their effects on WPC processing and mechanical properties. Work has been done to redesign the extrusion system setup to achieve smoother and stronger profiles. A guiding shaper, submerged in the water, has been designed to guide the material directly through water immediately after exiting the ...

2010-01-01

265

Conductivity and Viscosity Measurements for Binary Lysozyme Chloride Aqueous Solution and Ternary Lysozyme-Salt-Water Solution  

CERN Document Server

We use the conductimetric method, adequate to electrolytes, to determine the lysozyme charge in lys-water and ternary lys-salt-water systems. We measured also the viscosities for the above binary and ternary systems in the same conditions at pH$=4.5$ and T$=298$ K, measurements that allow us to see any effect of viscosity on cations mobilities and implicitly on the lysozyme charge. The method is illustrated for the lysozyme chloride aqueous solution system at 25$^o$ C, using the data reported here for pH$=4.5$ at 0.15, 0.6, 0.8, 1., 1.5, 2., 2.5, 3., 3.5 mM (mg/mL) lysozyme chloride concentrations. The method was also applied to ternary lys-salt-water systems in the same conditions at pH$=4.5$ and T$=25^o$ C. Ternary conductivities are reported for a mean concentration 0.6 mM of lysozyme chloride in all systems and a ...

2004-01-01

266

Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions  

Energy Technology Data Exchange (ETDEWEB)

The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, ...

1999-06-19

267

Activities and activity ratios of U and Ra radioisotopes in drinking wells, springs and tap water samples in Morocco  

International Nuclear Information System (INIS)

Radiochemical results ("2"3"4U, "2"3"8U, "2"2"6Ra and "2"2"8Ra activities; "2"3"4U/"2"3"8U, "2"2"8Ra/"2"2"6Ra and "2"2"6Ra/"2"3"8U activity ratios) are reported for 31 drinking water samples collected from 8 wells, 12 hot mineral springs, 5 cold springs, and 6 tap water samples. Activities of the Ra isotopes were measured by gamma spectrometry using a low background and high efficiency well type germanium detector. The U isotopes were counted in an alpha spectrometer. The results show that "2"3"8U activity varies between 4.46 and about 308 mBq l"-"1 in wells, 0.59 and 17.88 mBq l"-"1 in hot springs, 2.19 and 3.21 mBq l"-"1 in cold springs, and between 2.5 and 15.70 mBq l"-"1 in tap water samples. "2"3"4U/"2"3"8U activity ratio is generally higher than 1 which is the equilibrium activity ratio value in closed systems. It varies in the ranges 0.79-2.11 in wells, 0.97-7.39 in hot springs, 2.53-8.30 in cold ...

268

Optimal scheduling of power systems with pumped hydropower storage plants adopting nonlinear programming techniques  

Energy Technology Data Exchange (ETDEWEB)

The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be ...

1980-12-01

269

A model for the calculation of vent clearing transients in pressure suppression systems  

International Nuclear Information System (INIS)

For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations ...

1975-09-01

270

Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code  

Energy Technology Data Exchange (ETDEWEB)

In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...

1998-12-01

271

Deployment Support Leading to Implementation  

Energy Technology Data Exchange (ETDEWEB)

The following paragraphs summarize the progress of each research project funded under the WVU Cooperative Agreement during the third quarter of 1997 (July - September 1997). The projects are arranged according to their 1997 WVU task number. WVU Focus Area 1.0: Subsurface Contaminants, Containment and Remediation Task No. 1.1: Project discontinued. Task No. 1.2: Development of Standard Test Protocols and Barrier Design Models for Desiccation Barriers (K. Amininan & S. Ameri): A number of experiments were preformed this period to evaluate the ability of the dried sand-packs to act as a barrier to liquids. Water infiltration tests were done with a constant head, dispersing 80 ml of water, and by adding water in small increments. Results indicate that when the water is spilled over the sand-pack, it has the tendency to channel through the sand-pack, significantly reducing the capacity of the dried zone ...

1997-10-01

272

Ecological sanitation: and sustainable sanitation system especially for poor and lowland countries  

International Nuclear Information System (INIS)

More than 80% of the people of Nepal are farmers and 90% of the farmers do farming for subsistence. Agricultural productions contribute about 50% of country's GDP. Agricultural sector has been categorized as the top priority sector since many years. The environment of the country has also deteriorated substantially by the unplanned and unscientific use of natural resources such as air, soil, water, air and forest. Fertility of the soil has also been declining and studies show that productions in mountains is decreasing at a rate of 40 Kg/ha. Yr (1). The Terai, a narrow strip of land in the south, is in heavy pressure due to over exploitation and population growth (both natural and migratory). Shallow groundwater (shallow tube wells) is the main source of drinking water in Terai (the lowland region of Nepal). A study conducted by Department of Water Supply and Sewerage (DWSS) showed that more than 55% of Terai tube wells are ...

2004-06-07

273

Ultra-high pressure water jet: Baseline report  

International Nuclear Information System (INIS)

The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of ...

1997-07-01

274

Summary of the Waste Management Programs at uranium recovery facilities as they relate to the 40 CFR Part 192 standards  

International Nuclear Information System (INIS)

This study evaluates the degree to which surface impoundments at licensed facilities comply with significant changes in NRC requirements initiated by enactment of EPA's final environmental standards for uranium recovery facilities (40 CFR Part 192). Impoundment liner requirements, ground-water protection standards, ground-water monitoring and corrective action programs, and site closure standards are the most significant regulatory modifications. The compliance status of 30 conventional mills and 31 in-situ mines is determined from a review of Nuclear Regulatory Commission and agreement state docket files through November, 1983. Results of this review show that a majority of conventional uranium mill tailings management systems are deficient with respect to liner requirements for new impoundments or proposed expansions to existing impoundments, as well as with respect to some aspects of ground-water ...

275

Salinity and hydrodynamics of the Holocene and upper Pleistocene beneath the Louisiana wetlands from electrical measurements  

Energy Technology Data Exchange (ETDEWEB)

A conceptual hydrodynamic model in the Holocene and upper Pleistocene beneath the Louisiana wetlands is described in terms of safety distributions. Porewater safety is calculated from electrical measurements, including resistivity soundings, electric logs, and electromagnetic profiling. Electrical measurements support the primary, basin-wide groundwater flow model; however, the data also indicate secondary contributions from expulsion of fluids under geopressure along active growth faults and from original waters of deposition. Expulsion of water from growth faults has been described previously for deeper sections of the Pleistocene, but has not been reported for the Holocene or upper Pleistocene beneath the Louisiana wetlands. Porewater chemistry variations beneath the coastal wetlands are a consequence of the following (in order of importance): (1) environment of deposition; (2) a basin-wide, regional flow system; (3) ...

1995-06-01

276

Proceedings: Water treeing and aging  

Energy Technology Data Exchange (ETDEWEB)

This report presents the record of the workshop Water Treeing and Aging.'' The workshop was held in Phoenix, Arizona on December 9--11, 1990 and was sponsored by the Distribution Program of the Electrical Systems Division of the Electric Power Research Institute (EPRI). Attendance at the workshop was by invitation only. Twenty two attendees from seven countries, from universities, research organizations, electric utilities and polymeric materials suppliers took part in this workshop. The workshop was designed to assess progress in the understanding of water treeing phenomena and polymeric cable insulation aging since the last meeting of a similar forum of experts, which was organized by the Office of Exploratory Research of EPRI in December 1985. The objective of the present workshop was to assess progress and to provide direction for further studies in this field. The discussions covered a wide range of ...

1991-10-01

277

Microbial indicators of environmental water pollution. Mizu kankyo ni okeru biseibutsu shihyo  

Energy Technology Data Exchange (ETDEWEB)

Microbial indicators in the environmental water are categorized as follows. 1. Index for pathogenic microbial contamination, especially enteric canal based ones. 2. Index for the ordinary microbial contamination. 3. Index for nutritive assessment. 4. Index for the treating effect of final effluent discharged into an environmental water. 5. Index for distinction of of the contamination source. Above 1 and 2'' are among the indices which cannot be replaced by other physico-chemical substances or indices. Up to the present time, 1'' is assessed by a coliform group and 2'' by the bacteria. Recently, however, the status on the microbial contamination of the environmental water is changing, thus urging the reexamination of the assessment systems. This report describes the following items. Characteristics and the elements of the indices (enteric canal based ...

1990-08-10

278

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water ...

1977-11-01

279

Isotope exchange reaction between tritiated water and hydrogen on SiC  

Energy Technology Data Exchange (ETDEWEB)

SiC has been considered as a primary candidate material for a first wall component in future fusion reactor because it has been claimed that SiC has excellent high-temperature properties, good chemical stability and low activation. However, the behavior of tritium on SiC has not been discussed yet. In this study, tritium trapping capacity on the surface of SiC was experimentally obtained at the temperature range of 25-800 deg. C in consideration of tritium trapping to the experimental system. The capacity, which was independent of the water vapor pressure in the gas phase and the temperature, was determined as about 10{sup 6} Bq/cm{sup 2}. The isotope exchange reaction rate between tritiated water in a gas phase and hydrogen on the surface was quantified at the temperature of 25, 500 and 700 deg. C in consideration of the behavior of tritium trapping at change of experimental condition by the numerical curve fitting method ...

2003-11-15

280

Isotope exchange reaction between tritiated water and hydrogen on SiC  

International Nuclear Information System (INIS)

SiC has been considered as a primary candidate material for a first wall component in future fusion reactor because it has been claimed that SiC has excellent high-temperature properties, good chemical stability and low activation. However, the behavior of tritium on SiC has not been discussed yet. In this study, tritium trapping capacity on the surface of SiC was experimentally obtained at the temperature range of 25-800 deg. C in consideration of tritium trapping to the experimental system. The capacity, which was independent of the water vapor pressure in the gas phase and the temperature, was determined as about 10"6 Bq/cm"2. The isotope exchange reaction rate between tritiated water in a gas phase and hydrogen on the surface was quantified at the temperature of 25, 500 and 700 deg. C in consideration of the behavior of tritium trapping at change of experimental condition by the numerical curve fitting method applying ...

2003-11-15

281

Development of in-vessel type control rod drive mechanism for marine reactor  

Energy Technology Data Exchange (ETDEWEB)

A highly reliable control rod drive mechanism (CRDM) installed inside the reactor vessel has developed for use of an advanced marine reactor. This CRDM contributes to compactness and simplicity of the reactor system, and it can eliminate the possibility of a rod ejection accident. The CRDM works in the high temperature and high pressure water - 310degC and 12 MPa, the same atmosphere as the primary loop. Driving force is produced by a synchronous motor with the rotor of a permanent magnet, which has been developed. An innovative latch mechanism using separable ball nuts can latch driving shaft connecting the control rod and de-latch it for scram. The rod position detector using a magnetostrictive wire type sensor on the principle of Wiedeman effect has been developed, accuracy of which is verified to have a detecting error within 1.2 mm. Ball bearings for thrust and radial supports in rotation have been developed to be capable of working under ...

2001-07-01

282

Biological treatment process for removing petroleum hydrocarbons from oil field produced waters  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of removing petroleum hydrocarbons from oil fields produced waters using biological treatment was evaluated under laboratory and field conditions. Based on previous laboratory studies, a field-scale prototype system was designed and operated over a period of four months. Two different sources of produced waters were tested in this field study under various continuous flow rates ranging from 375 1/D to 1,800 1/D. One source of produced water was an open storage pit; the other, a closed storage tank. The TDS concentrations of these sources exceeded 50,000 mg/l; total n-alkanes exceeded 100 mg/l; total petroleum hydrocarbons exceeded 125 mg/l; and total BTEX exceeded 3 mg/l. Removals of total n-alkanes, total petroleum hydrocarbons, and BTEX remained consistently high over 99%. During these tests, the energy costs averaged $0.20/bbl at 12 bbl/D.

1995-12-31

283

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their ...

1999-11-22

284

The first PANDA tests  

International Nuclear Information System (INIS)

The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be favorably responsive and highly robust to changes in the thermal ...

285

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of ...

286

Design of air-conditioning installations; Conception des installations climatiques et de conditionnement de l'air  

Energy Technology Data Exchange (ETDEWEB)

This guidebook concerns the design of air-conditioning and air-treatment installations in recent and old buildings. The design of indoor atmosphere treatment systems is based on a rigorous and safe methodology. The following aspects are reviewed: situation of ambient air treatment, different aspects of a project, humid-air technique, principles of air treatment, basic conditions for a successful project, determination of enthalpy and hydric loads of rooms, design of ambient treatment systems, cold water production using a thermodynamical system, aeraulics, hydraulics, acoustics, logics of operation, forecasting of energy consumptions, global management of air-conditioning installations, ambient air-treatment systems. (J.S.)

1999-07-01

287

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, ...

2005-11-23

288

NICE3: Dyebath reuse in carpet manufacturing  

Energy Technology Data Exchange (ETDEWEB)

Fact sheet on an analysis system for dyebath processes in the carpet manufacturing industry written for the NICE3 Program. The Georgia Institute of Technology (G.I.T.) has developed an effective automated dyebath analysis and reuse system that improves the energy, environmental, and economic performance of dyehouse batch operations. The new system enables dyeing solutions to be accurately monitored and adjusted for reuse. According to industry estimates, 160 pounds of water are used to produce each pound of textile product. The current wasteful batch dyeing process requires all water and residual chemicals, as well as the energy required to heat the mixture for dyeing, to be dumped after one application. Spent dyebaths can only be reused after they are sampled, analyzed, and reconstituted, a process requiring labor and expertise that are unavailable in the dyehouses. Therefore, ...

1999-09-29

289

Fuzzy decision making in multiobjective long-term scheduling of hydrothermal system  

Energy Technology Data Exchange (ETDEWEB)

In the paper, a fuzzy decision-making methodology is presented to decide the generation schedule of long-term hydrothermal problems with explicit recognition of statistical uncertainties in system production cost data, NO{sub x} emission data, system load demand and hydro reservoir water inflows. In deciding the optimal operation, three objectives operating cost, NO{sub x} emission and unsatisfied load demand over the whole of the planning period are simultaneously minimised. Specific technique is put forth to convert the stochastic models into their deterministic equivalents. The weighted minimax method is used to simulate the tradeoff relation between the conflicting objectives in the non-inferior domain. The fuzzy set theory is exploited to choose the best operating point over the tradeoff curve. An efficient decomposition technique is applied to reduce the complexity of the problem. In each subproblem, thermal ...

2001-01-01

290

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...

291

A model for calculation of RCS pressure during reflux boiling under reduced inventory conditions and its assessment against PKL data  

International Nuclear Information System (INIS)

There has been recent interest in the United States concerning the loss of residual heat removal system (RHRS) under reduced coolant inventory conditions for pressurized water reactors. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-III experimental facility at Siemens-KWU to supply applicable data. Recently, an NRC-sponsored effort has been undertaken at the Idaho National Engineering Laboratory to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following the long term loss-of-RHRS during reduced inventory operation. The thermal-hydraulic response of a closed reactor coolant system during such a transient is investigated in this report. Some of the specific processes investigated include: reflux condensation in the steam generators, the corresponding pressure increase in the reactor ...

1992-04-01

292

A model for calculation of RCS pressure during reflux boiling under reduced inventory conditions and its assessment against PKL data  

International Nuclear Information System (INIS)

There has been recent interest in the United States concerning the loss of residual heat removal system (RHRS) under reduced coolant inventory conditions for pressurized water reactors. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-HI experimental facility at Siemens-KWU to supply applicable data. Recently, an NRC-sponsored effort has been undertaken at the Idaho-National Engineering Laboratory to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following the long term loss-of-RHRS during reduced inventory operation. The thermal-hydraulic response of a closed reactor coolant system during such a transient is investigated in this report. Some of the specific processes investigated include: reflux condensation in the steam generators, the corresponding pressure increase in the reactor ...

1991-10-28

293

Treatment of Produced Waters Using a Surfactant Modified Zeolite/Vapor Phase Bioreactor System  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes work performed on this project from October 2004 through March 2005. In previous work, a surfactant modified zeolite (SMZ) was shown to be an effective system for removing BTEX contaminants from produced water. Additional work on this project demonstrated that a compost-based biofilter could biodegrade the BTEX contaminants found in the SMZ regeneration waste gas stream. However, it was also determined that the BTEX concentrations in the waste gas stream varied significantly during the regeneration period and the initial BTEX concentrations were too high for the biofilter to handle effectively. A series of experiments were conducted to determine the feasibility of using a passive adsorption column placed upstream of the biofilter to attenuate the peak gas-phase VOC concentrations delivered to the biofilter during the SMZ regeneration process. In preparation for the field test of the SMZ/VPB treatment ...

2005-03-11

294

West Siberian basin hydrogeology - regional framework for contaminant migration from injected wastes  

Energy Technology Data Exchange (ETDEWEB)

Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed models of contaminated ...

1994-05-01

295

Waste treatment process for removal of contaminants from aqueous, mixed-waste solutions using sequential chemical treatment and crossflow microfiltration, followed by dewatering  

Energy Technology Data Exchange (ETDEWEB)

In processes of this invention aqueous waste solutions containing a variety of mixed waste contaminants are treated to remove the contaminants by a sequential addition of chemicals and adsorption/ion exchange powdered materials to remove the contaminants including lead, cadmium, uranium, cesium-137, strontium-85/90, trichloroethylene and benzene, and impurities including iron and calcium. Staged conditioning of the waste solution produces a polydisperse system of size enlarged complexes of the contaminants in three distinct configurations: water-soluble metal complexes, insoluble metal precipitation complexes, and contaminant-bearing particles of ion exchange and adsorbent materials. The volume of the waste is reduced by separation of the polydisperse system by cross-flow microfiltration, followed by low-temperature evaporation and/or filter pressing. The water produced as filtrate is discharged if it ...

1994-01-01

296

Waste treatment process for removal of contaminants from aqueous, mixed-waste solutions using sequential chemical treatment and crossflow microfiltration, followed by dewatering  

Energy Technology Data Exchange (ETDEWEB)

In processes of this invention aqueous waste solutions containing a variety of mixed waste contaminants are treated to remove the contaminants by a sequential addition of chemicals and adsorption/ion exchange powdered materials to remove the contaminants including lead, cadmium, uranium, cesium-137, strontium-85/90, trichloroethylene and benzene, and impurities including iron and calcium. Staged conditioning of the waste solution produces a polydisperse system of size enlarged complexes of the contaminants in three distinct configurations: water-soluble metal complexes, insoluble metal precipitation complexes, and contaminant-bearing particles of ion exchange and adsorbent materials. The volume of the waste is reduced by separation of the polydisperse system by cross-flow microfiltration, followed by low-temperature evaporation and/or filter pressing. The water produced as filtrate is discharged if it ...

1994-11-22

297

Nitrogen Requirements and Balance of Protected Cucumber in Coastal Lebanon  

International Nuclear Information System (INIS)

Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of ...

2003-10-01

298

Liquid zone system events at Wolsong Unit 2  

International Nuclear Information System (INIS)

On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) ...

1998-09-07

299

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46{sup o}C to 31-36{sup o}C. (author)

2004-06-01

300

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

International Nuclear Information System (INIS)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 deg. C to 31-36 deg. C.

2004-06-01

301

A study on the photocatalytic decomposition reactions of organics dissolved in water (II)  

Energy Technology Data Exchange (ETDEWEB)

Experiments on aqueous TiO{sup 2} photocatalytic reaction characteristics of 4 nitrogen-containing and 12 aromatic organic compounds were carried out. Based on the values calculated for the distribution of ionic species and atomic charge, the characteristics of their photocatalytic decomposition were estimated. It was shown that the dependence of decomposition of the N-containing compounds were linearly proportional to their nitrogen atomic charge values, while that of the aromatic compounds were inversely proportional. The effects of aqueous pH, oxygen content and concentration on the TiO{sup 2} photocatalytic characteristics of EDTA-Cu(II) and EDTA-Fe(III) were experimentally investigated. All EDTA systems were decomposed better in the pH range of 2.5{approx}3.0 and with more dissolved oxygen. These results could be applied to a unit process for removal of organic impurities dissolved in a source water of the system ...

2001-01-01

302

Wetland treatment of oil and gas well wastewaters. Quarterly technical report, May 25, 1992---August 24, 1992  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to extend the knowledge base for wetland treatment to include processes and substances of particular importance to small, on-site systems receiving oil and gas well waste water. Collection of data on the sorption of heavy metals and the degradation of toxic organics is one of the key tasks. The toxic organics phenolics and anthracene, and chromium and copper have been selected as target adsorbates. An information search was performed on oil refinery waste treatment wetland systems.

1995-11-01

303

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

304

Process for removing sulfur dioxide from gas streams  

Science.gov (United States)

In the prevention of atmospheric pollution by sulfur dioxide emissions from acid absorbers in contact process sulfuric acid plants in which the unconverted SO/sub 2/ is accumulated by adsorption in a zeolite adsorbent bed and desorbed back into the acid production system, it is found that ambient moist air, after partial dehydration in an acid scrubber is suitably used both to cool down and hot purge desorb the zeolite beds. In addition the pure water derived from the ambient air is advantageously used in the acid-making system.

1976-10-26

305

Process and system for treatment of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

In a treatment system of radioactive waste solution including sodium sulfate generated from a boiling water type nuclear reactor, waste solution is fed into a thin film evaporator where the waste solution is evaporated and made into powder while precipitating in a peripheral surface of the evaporator vessel. The surface of the precipitated solid is wiped by rotating wiper blades and removed off as radioactive solid powder. The rotational speed of a rotor to which the wiper blades are secured is controlled at a minimum and necessary rotational speed which contributes to make the waste solution into the powder so that the rate of worn out of the wiper blade is decreased.

1985-07-02

306

Proceedings of the fourth international airborne remote sensing conference and exhibition/ 21st Canadian symposium on remote sensing  

Energy Technology Data Exchange (ETDEWEB)

The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.

1999-07-01

307

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

308

VWS Westgarth supplies treatment systems for Daewoo FPSO vessel  

British Library Electronic Table of Contents (United Kingdom)

VWS Westgarth, a subsidiary of Veolia Water Solutions & Technologies (VWS), has been awarded a multi-million dollar contract by Daewoo Shipbuilding & Marine Engineering Co (DSME), under which it will design, supply and deliver two treatment units for use on a floating production storage and offloading (FPSO) vessel.

2011-01-01

309

Underground piping handbook  

Energy Technology Data Exchange (ETDEWEB)

This book provides the information required to design and prepare construction drawings, and to install, inspect, test, and commission buried piping. Both pressure and gravity piping are covered, including water, steam, gases, and sewers. Directed primarily toward underground industrial piping systems, this is a succinct, well-organized compilation of practical knowledge. Checklists, examples, tables, charts, nomographs, short cuts, and helpful hints gained through years of experience complete this timely and useful ''how to'' book.

1985-01-01

310

Stakeholder acceptance analysis: In-well vapor stripping, in-situ bioremediation, gas membrane separation system (membrane separation)  

Energy Technology Data Exchange (ETDEWEB)

This document provides stakeholder evaluations on innovative technologies to be used in the remediation of volatile organic compounds from soils and ground water. The technologies evaluated are; in-well vapor stripping, in-situ bioremediation, and gas membrane separation.

1995-12-01

311

Spectral characteristics of lignite open cast mining systems: a preliminary status  

Energy Technology Data Exchange (ETDEWEB)

The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.

1999-07-01

312

Self installable: floating production facility requires only light support craft  

Energy Technology Data Exchange (ETDEWEB)

An integrated multiwell floating production, storage, and offloading (FPSO) facility was successfully installed at the Tazerka field offshore Tunisia in 1982. Because there is good reason to believe that the installation techniques developed for the Tazerka FPSO can be applied to even larger systems in deeper waters, this paper presents the design and step-by-step installation procedures developed at Tazerka.

1983-05-01

313

Remote sensing for environmental monitoring and resource management. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The subject of this volume is remote sensing for environmental monitoring and resource management. This session is divided in eight parts. First part is on general topics, methodology and meteorology. Second part is on geology, environment and land cover. Third part is on disaster monitoring. Fourth part is on operational status of remote sensing. Fifth part is on coastal zones and inland waters. Sixth and seventh parts are on forestry and agriculture. Eighth part is on instrumentation and systems. (A.B.). refs., figs., tabs.

1992-12-31

314

Offshore: North Sea facility gets the CETCO solution  

British Library Electronic Table of Contents (United Kingdom)

CETCO Oilfield Services, suppliers of environmental systems, have undertaken a project to treat contaminated water returns on a Floating, Production, Storage and Offloading (FPSO) facility in the North Sea. The solution sees fluids treated during oil well clean-up operations, reducing the potential for overboard oil discharges, and resulting production upsets.

2006-01-01

315

New technologies in fossil-fuel utilization  

Energy Technology Data Exchange (ETDEWEB)

This document contains the outline and viewgraphs used in the speech. Topics covered are: conventional oil and gas recovery; unconventional oil and gas sources; oil shale resources; conventional coal combustion; advanced fossil power systems; fluidized bed combustion; coal/oil or coal/water mixtures; and gaseous and liquid fuels from coal. (DMC)

1982-01-01

316

NAME=\\  

Wastenet

... Electro-Osmotic Pulse (EOP) technology forces moisture to flow through concrete surfaces against the hydraulic gradient when an electric field is applied to an embedded anode system. This flow is initiated by the movement of cations (positively charged ions) present in a porous medium such as concrete toward the negative earth. Water surrounding the cations moves with them. The Corps of Engineers owns and maintains many buried ...

317

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

318

Internal dose from tritium at Wolsung nuclear power plant  

International Nuclear Information System (INIS)

Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction "2H(n,#gamma#)"3H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D_2O and 35 Ci/kg-D_2O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium contribution to the ...

1995-02-01

319

Interfacial Area and Interfacial Transfer in Two-Phase Flow Systems (Volume IV. Chapters 15-19)  

Energy Technology Data Exchange (ETDEWEB)

Experiments were performed on horizontal air-water bubbly two-phase flow, axial flow, stratified wavy flow, and annular flow. Theoretical studies were also undertaken on interfacial parameters for a horizontal two-phase flow.

2003-03-15

320

Industrial waste management information for 1990 and record-to-date  

Energy Technology Data Exchange (ETDEWEB)

This product provides detailed data and graphics on airborne and liquid effluent releases, fuel oil consumption, and water usage for the calendar year 1990. It summarizes industrial waste data records compiled since 1971 for the Idaho National Engineering Laboratory (INEL). The data presented are from the INEL Industrial Waste Management Information System (IWMIS).

1991-08-01

321

Incident report: spillage of reactor coolant at Wolsung  

International Nuclear Information System (INIS)

Late last year the Wolsung Candu in Korea suffered an incident which resulted in heavy water being released from the primary system into the containment. With the unit now back at full power, this article examines the causes of the incident and the action which is being taken to prevent it happening again. (author).

1985-01-01

322

Idaho National Engineering Laboratory Nonradiological Waste Management Information for 1992 and record to date  

Energy Technology Data Exchange (ETDEWEB)

This document provides detailed data and graphics on airborne and liquid effluent releases, fuel oil and coal consumption, water usage, and hazardous and mixed waste generated for calendar year 1992. This report summarizes industrial waste data records compiled since 1971 for the Idaho National Engineering Laboratory (INEL). The data presented are from the INEL Nonradiological Waste Management Information System.

1993-08-01

323

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

324

French power for Jersey goes under water  

Energy Technology Data Exchange (ETDEWEB)

A proposed project by which the island of Jersy could buy electric power from France is discussed. The interconnector will be capable of transmitting up to 50MW. Included in the project will be 27 km of submarine cable and 23 km of underground cable. An oil-filled cable containing 120 mm diameter copper conductors and weighing 47 kg/m is used. Details of the installation and oil system are given.

1983-01-21

325

Environmental effects and energy efficiency in building design - a green building approach. Pt. 1. Energy efficiency techniques  

Energy Technology Data Exchange (ETDEWEB)

A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)

1993-12-31

326

Crumbling case for nuclear power  

Energy Technology Data Exchange (ETDEWEB)

In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.

1983-01-01

327

Combined-cycle cogen plant a successful good neighbor  

Energy Technology Data Exchange (ETDEWEB)

This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.

1993-04-01

328

Cold regions hydrology and hydraulics  

Energy Technology Data Exchange (ETDEWEB)

This monograph addresses a narrow aspect of cold regions engineering, namely the effects of cold weather on the traditional civil engineering disciplines of hydrology and hydraulics. Hydrologic and hydraulic considerations in the design, construction, and operation of civil works are very important. Many of the problems encountered in the design and construction of buildings, transportation systems, water supply facilities, waste treatment facilities, and hazardous waste disposal facilities, for example are closely tied to the characteristics of the site hydrology.

1990-01-01

329

Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).

1997-06-21

330

100 Areas: (For Technical Progress Letter No. 97), May 7--13  

Science.gov (United States)

Physics information for the D and F piles is presented. Thermal conductivity, reactivity, and irradiation levels are included. Concerning the cooling systems: process water control, pressure drip studies, purging studies, corrosion, and gun barrel clearance of expanded graphite are discussed. (GHH)

1946-05-17

331

Review of fires and fire control methods for nuclear air cleaning systems  

International Nuclear Information System (INIS)

The nuclear power industry has experienced four carbon based adsorbent fires in its history, one was of the Monticello Standby Gas Treatment System and other three were in various off-gas delay beds. Although, some of the latter may not be classified as a full fledged fires. There were a number of experiments performed relating to igniting carbon beds and experiments relating to attempts at extinguishing set fires reported in the literature. Review of these experiments indicates that fire resulting from decay heat of adsorbed radioactive iodine is not justified even under the somewhat unrealistic source terms still in effect. At the same time the non-nuclear chemical industry application of carbon base adsorbents for solvent recovery has resulted in numerous fires and significant property losses. Fire control systems installed in nuclear air cleaning systems in the US consists of water deluge. ...

1987-05-01

332

Large temperature differential thermal storage system. Its design and evaluation  

Energy Technology Data Exchange (ETDEWEB)

A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was ...

1996-07-01

333

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma ...

2006-11-13

334

Evaluation of the Validity of Groundwater Samples Obtained Using the Purge Water Management System at SRS  

Energy Technology Data Exchange (ETDEWEB)

As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical ...

1999-04-27

335

Water Quality Criteria | Water Quality Criteria | US EPA  

Science.gov (United States)

for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...

2011-08-28

336

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...

1980-01-01

339

Numerical analysis and visualization experiment on behavior of borated water during MSLB with RCP running mode in an advanced reactor  

Energy Technology Data Exchange (ETDEWEB)

The core bypass phenomenon of borated water injected through direct vessel injection (DVI) nozzles in APR1400 (Advanced Power Reactor 1400MWe) during main steam line break (MSLB) accidents with a reactor coolant pump (RCP) running mode has been simulated using a two-channel and one-dimensional system analysis model code (MARS), and a three-dimensional computational fluid dynamics (CFD) code (FLUENT). A visualization experiment has also been performed using a scaled-down model of the APR1400. The MARS analysis has predicted a serious core bypass phenomenon of borated water, while the CFD analysis has shown results opposite to the MARS results. The CFD analysis has shown that the flow pattern in the downcomer is fully three-dimensional and that vortex flow structures are formed near the cold legs so that the borated water might pass without difficulty into the high flow region of the cold legs and flow ...

2007-04-15

340

Distribution of polycyclic aromatic hydrocarbons in water and surface sediments from Daya Bay, China  

International Nuclear Information System (INIS)

Findings indicate an urgent need to establish a monitoring program for persistent organic pollutants in water and sediment. - Marine culture is thriving in China and represents a major component of the regional economy in coastal zones, yet the environmental quality of many of those areas has never been studied. This paper attempts to investigate the quality status of Daya Bay, a key aquaculture area in China. The levels of 16 polycyclic aromatic hydrocarbons (PAHs) were determined in water and sediment samples of the bay. The total concentrations of 16 PAHs varied from 4228 to 29325 ng l"-"1 in water, and from 115 to 1134 ng g"-"1 dry weight in sediments. In comparison to many other marine systems studied, the PAH levels in Daya Bay waters were relatively high, and at six sites they were sufficiently high (>10 #mu#g l"-"1) to cause acute toxicity. The PAH composition pattern in ...

2003-02-01

341

Chemical thermodynamics of silica: a critique on its geothermometer  

Energy Technology Data Exchange (ETDEWEB)

The chemical thermodynamic concepts used in the calculation of solubility data of silica (quartz) are presented taking into account the PVT characteristics of water. The temperature-dependence trends between the thermodynamically calculated and the experimental quartz solubility data are very similar, but the values are widely different at high temperatures. The experimental solubility, especially along the saturation curve at high temperature and thermodynamic data for silica need to be reevaluated in order to use silica chemistry to understand geological processes. There could exist a wide range of values for silica solubility at a specified temperature, depending upon the amount of water in the reaction vessel. Thus the silica contents in geothermal fluid, in general, cannot be used as a geothermometer to estimate the reservoir temperature. The derivation of a silica geothermometer needs an extra assumption about the total amount of ...

2000-06-01

342

Preliminary delineation of natural geochemical reactions, Snake River Plain aquifer system, Idaho National Engineering Laboratory and vicinity, Idaho  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, is conducting a study to determine the natural geochemistry of the Snake River Plain aquifer system at the Idaho National Engineering Laboratory (INEL), Idaho. As part of this study, a group of geochemical reactions that partially control the natural chemistry of ground water at the INEL were identified. Mineralogy of the aquifer matrix was determined using X-ray diffraction and thin-section analysis and theoretical stabilities of the minerals were used to identify potential solid-phase reactants and products of the reactions. The reactants and products that have an important contribution to the natural geochemistry include labradorite, olivine, pyroxene, smectite, calcite, ferric oxyhydroxide, and several silica phases. To further identify the reactions, analyses of 22 representative water samples from sites tapping the Snake River Plain aquifer ...

1997-05-01

343

ESBWR related passive decay heat removal tests in PANDA  

International Nuclear Information System (INIS)

A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and ...

1999-04-19

344

Photocatalytic oxidation and reduction chemistry and a new process for treatment of pink water and related contaminated water  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to develop new photocatalytic or other innovative process chemistry for the treatment of pink water and related contaminated water.

1996-10-01

345

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the ...

1995-01-01

346

Potential for hot-dry-rock geothermal resources: experimental results  

Science.gov (United States)

Hot dry rock (HDR) contains insufficient permeability and fluid for natural hydrothermal development, but water pumped in a circulation loop through a HDR reservoir (hydraulically fractured between two drill holes) is being tested and evaluated. The formation of such in situ heat transfer systems, and subsequent testing of the man-made geothermal reservoirs in the Jemez volcanic field, New Mexico have already indicated the technical feasibility of the hot dry rock (HDR) geothermal concept. Documented production history and heat-extraction data obtained during the period from 1978 to 1980 have confirmed heat transfer, low water loss, and predictable thermal drawdown models for the HDR systems. During a nine month test of closed-loop heat extraction operations, 15 x 10/sup 6/ kWh of thermal energy were produced. The effective heat-transfer area and volume of the reservoir increased due to secondary ...

1982-01-01

347

Development and Application of Subchannel Analysis Code Technology for Advanced Reactor Systems  

Energy Technology Data Exchange (ETDEWEB)

A study has been performed for the development and assessment of a subchannel analysis code which is purposed to be used for the analysis of advanced reactor conditions with various configurations of reactor core and several kinds of reactor coolant fluids. The subchannel analysis code was developed on the basis of MATRA code which is being developed at KAERI. A GUI (Graphic User Interface) system was adopted in order to reduce input error and to enhance user convenience. The subchannel code was complemented in the property calculation modules by including various fluids such as heavy liquid metal, gas, refrigerant,and supercritical water. The subchannel code was applied to calculate the local thermal hydraulic conditions inside the non-square test bundles which was employed for the analysis of CHF. The applicability of the subchannel code was evaluated for a high temperature gas cooled reactor condition and supercritical pressure conditions ...

2006-01-15

348

Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space ...

2010-01-15

349

SCDAP/RELAP5/MOD 3.1 code manual: Interface theory. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of off-site power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume describes the organization and manner of the interface between severe accident models which are ...

1995-06-01

350

RELAP5/MOD3 code manual. Volume 4, Models and correlations  

International Nuclear Information System (INIS)

The RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents and operational transients such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I presents modeling theory and associated numerical schemes; Volume II details instructions for code application and input data preparation; Volume ...

1995-08-05

351

Abiotic systems for the catalytic treatment of solvent-contaminated water  

Energy Technology Data Exchange (ETDEWEB)

Three abiotic systems are described that catalyze the reductive dehalogenation of heavily halogenated environmental pollutants, including carbon tetrachloride, trichloroethene, and perchloroethene. These systems include (a) an electrolytic reactor in which the potential on the working electrode (cathode) is fixed by using a potentiostat, (b) a light-driven system consisting of a semiconductor and (covalently attached) macrocycle that can accept light transmitted via an optical fiber, and a light-driven, two-solvent (isopropanol/acetone) system that promotes dehalogenation reactions via an unknown mechanism. Each is capable of accelerating reductive dehalogenation reactions to very high rates under laboratory conditions. Typically, millimolar concentrations of aqueous-phase targets can be dehalogenated in minutes to hours. The description of each system includes the elements of ...

1996-12-31

352

A desiccant dehumidifier for electric vehicle heating  

Energy Technology Data Exchange (ETDEWEB)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in the vehicle. Either strategy results in a substantial heating ...

1996-09-01

353

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. (Author)

1994-10-01

354

Revegetation/rock cover for stabilization of inactive U-tailings sites  

International Nuclear Information System (INIS)

Soil placed over any sealant/barrier system can provide a protective mantle if the soil is not lost by erosion. Vegetation is an attractive choice for controlling erosion because it can provide an economic self-renewing cover that serves to reduce erosion by both wind and water. Vegetation alone, however, may not adequately stabilize the surface in extremely arid areas. In those areas, a properly designed surface treatment of rock cover, perhaps in conjunction with vegetation, may be necessary to stabilize the tailings surfaces. The objective of this program is to establish guidelines for surface stabilization that are compatible with sealant/barrier systems and that are suited to soils and climates at inactive uranium mill tailings sites. These guidelines will provide the means to estimate potential vegetation cover, potential erosion, effects of surface treatments on sealant/barrier systems, and costs ...

1982-02-01

355

Reflux boiling heat removal in a scaled TMI-2 system test facility  

International Nuclear Information System (INIS)

An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.

1980-06-01

356

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

357

Public power's roots deep in the Northwest  

Energy Technology Data Exchange (ETDEWEB)

Municipal power systems developed early in the Pacific Northwest, but a new dimension was added in the 1930s when the public utility district (PUD) concept combining urban and rural areas encited vigorous debate and the public rejected private-utility candidates. A favorable national climate developed for consumer-owned systems during the 1920s and 30s encouraging the passage of the Federal Water Power Act, the creation of the Tennessee Valley Authority, the building of Hoover Dam, and the establishment of the Bonneville Power Administration. This article reviews developments following the Public Utility Act of 1935, which authorized the Federal Power Commission and the uniform system of accounts. After tracing the record of investigations and policy trends during the Roosevelt era, it concludes that utilities benefited from accounting regulations. (DCK)

1982-01-01

358

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the ...

359

Improvements on burnup chain model and group cross section library in the SRAC system  

Energy Technology Data Exchange (ETDEWEB)

Data and functions of the cell burnup calculation of the SRAC system were revised to improve mainly the accuracy of the burnup calculation of high conversion light water reactors (HCLWRs). New burnup chain models were developed in order to treat fission products (FPs) and actinide nuclides in detail. Group cross section library, SRACLIB-JENDL2, was generated based on JENDL-2 nuclear data file. In generating this library, emphasis was placed on FPs and actinides. Also revised were the data such as the average energy release per fission for various actinides. These improved data were verified by performing the burnup analysis of PWR spent fuels. Some new functions were added to the SRAC system for the convenience to yield macroscopic cross sections used in the core burnup process. (author).

1992-01-01

360

Dynamical Quasi-Stationary States in a system with long-range forces  

CERN Document Server

The Hamiltonian Mean Field model describes a system of N fully-coupled particles showing a second-order phase transition as a function of the energy. The dynamics of the model presents interesting features in a small energy region below the critical point. In particular, when the particles are prepared in a ``water bag'' initial state, the relaxation to equilibrium is very slow. In the transient time the system lives in a dynamical quasi-stationary state and exhibits anomalous (enhanced) diffusion and L\\'evy walks. In this paper we study temperature and velocity distribution of the quasi-stationary state and we show that the lifetime of such a state increases with N. In particular when the $N\\to \\infty$ limit is taken before the $t \\to \\infty$ limit, the results obtained are different from the expected canonical predictions. This scenario seems to confirm a recent conjecture proposed by C.Tsallis.

2001-01-01

361

Development of Methods for Obtaining Position Image and Chemical Binding Information from Flow Experiments of Porous Media  

Energy Technology Data Exchange (ETDEWEB)

Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.

1998-12-01

362

DOE Plutonium Disposition Study: Pu consumption in ALWRs. Volume 1, Final report  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) has contracted with Asea Brown Boveri-Combustion Engineering (ABB-CE) to provide information on the capability of ABB-CE`s System 80 + Advanced Light Water Reactor (ALWR) to transform, through reactor burnup, 100 metric tonnes (MT) of weapons grade plutonium (Pu) into a form which is not readily useable in weapons. This information is being developed as part of DOE`s Plutonium Disposition Study, initiated by DOE in response to Congressional action. This document, Volume 1, presents a technical description of the various elements of the System 80 + Standard Plant Design upon which the Plutonium Disposition Study was based. The System 80 + Standard Design is fully developed and directly suited to meeting the mission objectives for plutonium disposal. The bass U0{sub 2} plant design is discussed here.

1993-05-15

363

Cost optimization of a solar humidification?dehumidification desalination unit using mathematical programming  

British Library Electronic Table of Contents (United Kingdom)

In a previous paper, the performance of the humidification?dehumidification (HD) desalination process was optimized through mathematical programming. In this paper, by adding a solar system to the model, the total solar HD system is optimized. The main purpose of this optimization is the reduction of fresh water production costs. By using special operational and geographical constraints the model can be used for any region to determine optimum operation point of system. Results show that solution obtained by cost objective function has a cost 7?28% lower than other objective functions. Also recycling, in spite of the increase of productivity and decrease of specific thermal energy consumption of the HD process, increases the cost of production.

2009-01-01

364

Containment integrated leakage rate test (ILRT) of Indian PHWR  

International Nuclear Information System (INIS)

Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian Pressurized Heavy Water Reactor (PHWR) ...

2005-12-01

365

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the heat ...

2010-07-01

366

Benefit analysis and evaluation of pumped-storage plant in Taipower system  

Energy Technology Data Exchange (ETDEWEB)

The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.

1995-12-31

367

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

368

Synchrotron SAXS Studies of Nanostructured Materials and Colloidal Solutions: A Review  

Scientific Electronic Library Online (English)

Abstract in english Structural characterisations using the SAXS technique in a number of nanoheterogeneous materials and liquid solutions are reviewed. The studied systems are protein (lysozyme)/water solutions, colloidal ZnO particles/water sols, nanoporous NiO-based xerogels, hybrid organic-inorganic siloxane-PEG and PPG nanocomposites and PbTe semiconductor nanocrystals embedded in a glass matrix. These investigations also focus on the transformations of time-varying structures and on str (more) uctural changes related to variations in temperature and composition. The reviewed investigations aim at explaining the unusual and often interesting properties of nanostructured materials and solutions. Most of the reported studies were carried out using the SAXS beamline at the National Synchrotron Light Laboratory (LNLS), Campinas, Brazil.

2002-03-01

369

Sterically stabilized water based magnetic fluids: Synthesis, structure and properties  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluids (MFs), prepared by chemical co-precipitation followed by double layer steric and electrostatic (combined) stabilization of magnetite nanoparticles dispersed in water, are presented. Several combinations of surfactants with different chain lengths (lauric acid (LA), myristic acid (MA), oleic acid (OA) and dodecyl-benzene-sulphonic acid (DBS)) were used, such as LA+LA, MA+MA, LA+DBS, MA+DBS, OA+DBS, OA+OA and DBS+DBS. Static light scattering, transmission electron microscopy, small angle neutron scattering, magnetic and magneto-rheological measurements revealed that MFs with MA+MA or LA+LA biocompatible double layer covered magnetite nanoparticles are the most stable colloidal systems among the investigated samples, and thus suitable for biomedical applications.

2007-04-15

370

Special features of control and protection for large saturated steam turbines  

International Nuclear Information System (INIS)

For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).

371

Radiological operating experience at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.

1987-04-22

372

Quantum-chemical investigation of mechanism of dehydroxylation of crystalline and amorphous aluminosilicates  

Science.gov (United States)

Within the framework of the cluster approach and the semiempirical SCF MO LCAO method in the CNDO/BW valence approximation, possible pathways have been compared for the dehydroxylation of aluminosilicate systems. It has been shown that dehydroxylation as a result of splitting of a water molecule from an acidic bridge hydroxyl group and a more basic terminal group Al-OH is the most energyfavorable. Apparently, such a dehydroxylation pathway is primarily characteristic for amorphous aluminosilicates. Typical of crystalline aluminosilicates at moderate heat-treating temperature is dehydroxylation through splitting of a water molecule from an acidic bridge hydroxyl group and a neutral Si-OH group; at higher temperatures, there is a possible pathway of dehydroxylation of highsilica zeolites as a result of condensation of two acidic surface hydroxyls.

1986-07-01

373

Quantum simulation of molecular interaction and dynamics at surfaces  

British Library Electronic Table of Contents (United Kingdom)

The interaction between molecules and solid surfaces plays important roles in various applications, including catalysis, sensors, nanoelectronics, and solar cells. Surprisingly, a full understanding of molecule-surface interaction at the quantum mechanical level has not been achieved even for very simple molecules, such as water. In this mini-review, we report recent progresses and current status of studies on interaction between representative molecules and surfaces. Taking water/metal, DNA bases/carbon nanotube, and organic dye molecule/oxide as examples, we focus on the understanding on the microstructure, electronic property, and electron-ion dynamics involved in these systems obtained from first-principles quantum mechanical calculations. We find that a quantum mechanical description ...

2011-01-01

374

Production of tetrazolium salts under conditions of phase-transfer catalysis  

Energy Technology Data Exchange (ETDEWEB)

Recently the authors showed that tetrazolium salts can be obtained during the oxidation of substituted 1,3,5-triarylformazans with potassium permanganate in a two-phase organic solvent-water system. The role of phase-transfer catalyst in this reaction is played by the tetrazolium salt, which is formed in a small amount as the result of oxidation of the formazan at the phase boundary. The method is distinguished by its extreme simplicity. However, the yield of the tetrazolium salts fluctuates within wide limits and does not exceed 62%. This is due to the fact that as the reaction proceeds the pH of the aqueous phase increases from 6 to 12. At the same time it is known that tetrazolium salts are unstable in aqueous alkaline solutions. They found that if the aqueous phase is replaced by aqueous hydrochloric acid (5 wt. %) the yields of the tetrazolium salts (Ia-g) are increased to 70-87%. For convenience of isolation the readily ...

1988-06-20

375

PSPs at Bhira and Bhivpuri  

International Nuclear Information System (INIS)

Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.

1992-01-01

376

Modification of streaming potential by precipitation of calcite in a sand-water system: laboratory measurements in the pH range from 4 to 12  

British Library Electronic Table of Contents (United Kingdom)

SUMMARY Spontaneous potentials associated with volcanic activity are often interpreted by means of the electrokinetic potential, which is usually positive in the flow direction (i.e. Zeta potential of the rock is negative). The water-rock interactions in hydrothermal zones alter the primary minerals leading to the formation of secondary minerals. This work addresses the study of calcite precipitation in a sand composed of 98 per cent quartz and 2 per cent calcite using streaming potential measurements. The precipitation of calcite as a secondary mineral phase, inferred by high calcite saturation indices and by a fall in permeability, has a significant effect on the electrokinetic behaviour, leading to a significant reduction in the Zeta potential (in absolute value) and even a change in si...

2006-01-01

377

Modeling of batteries and fuel cells; Proceedings of the Symposium, Phoenix, AZ, Oct. 13-19, 1991  

Energy Technology Data Exchange (ETDEWEB)

The present volume on modeling of batteries and fuel cells discusses the significance of the effectiveness factor for flooded porous electrodes, active pore distribution spectroscopy for characterizing porous battery electrodes, the agglomerate model for porous electrodes, and dynamic-performance measurements of battery cells for electric vehicles and other applications. Attention is given to mathematical modeling of a primary zinc/air battery, mathematical modeling of Grace Li-TiS2 cells, modeling of electrocrystallization processes in battery systems, and rotating disk electrode studies in molten Li/K carbonate eutectic. Topics addressed include the variability of nickel oxide cathode dissolution in molten carbonate fuel cells, water transport properties of fuel cell ionomers, modeling water content effects in polymer electrolyte fuel cells, and computer algebra applied in electrochemistry and fuel cell modeling.

1991-01-01

378

Measurement of Lake Roosevelt biota in relation to reservoir operations. Appendices 1991  

International Nuclear Information System (INIS)

This report consists of appendices A-F containing the biological data which were collected from Lake Roosevelt, Washington. The data are to be used in the design of a computer model that would predict biological responses of reservoir operations as part of the System Operation Review program. Major components of the model included: Quantification of impacts to phytoplankton, zooplanktons, benthic invertebrates, and fish caused by reservoir drawdowns and low water retention times; quantification of number, distribution, and use of fish food organisms in the reservoir by season; determination of seasonal growth of fish species as related to reservoir operations, prey abundance and utilization; and quantification of entrainment levels of zooplankton and fish as related to reservoir operations and water retention times.

1995-11-05

379

Mathematical model for radon diffusion in earthen materials  

Energy Technology Data Exchange (ETDEWEB)

Radon migration in porous, earthen materials is characterized by diffusion in both the air and water components of the system as well as by the interaction of the radon between the air and water. The size distribution and configuration of the pore spaces and their moisture distributions are key parameters in determining the radon diffusion coefficient for the bulk material. A mathematical model is developed and presented for calculating radon diffusion coefficients solely from the moisture content and pore size distribution of a soil, reducing the need for resorting to radon diffusion measurements. The resulting diffusion coefficients increase with the median pore diameter of the soil and decrease with increasing widths of the pore size distribution. The calculated diffusion coefficients are suitable for use in simple homogeneous-medium diffusion expressions for predicting radon transport and compare well with measured ...

1982-10-01

380

Low temperature surface modifications of polyacrylonitrile ultrafiltration membranes: 1. Plasma treatment effects  

Energy Technology Data Exchange (ETDEWEB)

Excitation of low temperature helium or helium/water plasma and subsequent exposure to air of polyacrylonitrile (PAN) ultrafiltration membranes was used to hydrophilize the surface of these materials. We analyzed the effectiveness of this approach as a function of plasma operating variables including gas phase composition, plasma power, treatment time and system pressure. Following the changes in physical and chemical composition of the PAN surface resulting from these modifications was a major aspect of this work. Techniques such as the captive bubble contact angle method, ellipsometry, ESCA, and FTIR-ATR were all used. In addition, the formation and life-time of peroxides during these processes were determined. At low powers (<25W) and short treatment periods ({<=}30 sec), the main chemical conversion of PAN surfaces was simultaneous hydrophilization and stabilization via PAN cyclization. Relatively small water ...

1995-12-01

381

Gross decontamination experiment report  

International Nuclear Information System (INIS)

A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system ...

382

Geothermal resources of the Green River Basin, Wyoming, including thermal data for the Wyoming portion of the Thrust Belt  

Energy Technology Data Exchange (ETDEWEB)

The geothermal resources of the Green River basin were investigated. Oil-well bottom-hole temperatures, thermal logs of wells, and heat flow data have been interpreted within a framework of geologic and hydrologic constraints. Basic thermal data, which includes the background thermal gradient and the highest recorded temperature and corresponding depth is tabulated. It was concluded that large areas are underlain by water at temperatures greater than 120/sup 0/F. Although much of this water is too deep to be economically tapped solely for geothermal use, oil and gas wells presently provide access to this significant geothermal resource. Isolated areas with high temperature gradients exist. These areas - many revealed by hot springs - represent geothermal systems which might presently be developed economically. 34 refs., 11 figs., 8 tabs. (ACR)

1985-01-01

383

GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992  

Science.gov (United States)

The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.

1993-08-01

384

Flow visualization of liquid metal by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.

1994-12-31

385

Flow visualization of liquid metal by neutron radiography  

International Nuclear Information System (INIS)

Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.

1994-07-01

386

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe  

International Nuclear Information System (INIS)

To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).

1994-05-01

387

Environmental surveillance at Hanford for CY-1979  

Energy Technology Data Exchange (ETDEWEB)

Environmental data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, and game birds), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1979 were indistinguishable from background levels. The data are summarized in the following highlights. Air quality measurements of NO/sub 2/ in the vicinity of the Hanford Site and releases of SO/sub 2/ onsite were well within the applicable federal and state standards. Particulate air concentrations exceed the standards primarily because of agricultural activities in the area. Discharges of waste water from Hanford facilities in the Columbia River under the National Pollution Discharge Elimination System (NPDES) permit were all within the parameter limits on the permit.

1980-04-01

388

Electrochemical characterization and CFD simulation of flow-assisted corrosion of aluminum alloy in ethylene glycol-water solution  

British Library Electronic Table of Contents (United Kingdom)

An impingement jet system was used to study flow-assisted corrosion (FAC) of 3003 aluminum (Al) alloy in ethylene glycol-water solutions that simulates the automotive coolant by corrosion potential and electrochemical impedance spectroscopy (EIS) measurements as well as computational fluid dynamics (CFD) simulation. The effects of solution pH and fluid impact angle on Al FAC were determined. An increase of solution pH enhances the activity of Al due to dissolution of Al oxide film in alkaline environment. Moreover, Al activity decreases with the increasing fluid impact angle to the specimen. A CFD simulation shows that, with the increase of impact angle, the electrode area under high-velocity flow field decreases and that under low-velocity flow field increases. Consequently, the shear str...

2008-01-01

389

Effects of coolant chemistry on corrosion of 3003 aluminum alloy in automotive cooling system  

British Library Electronic Table of Contents (United Kingdom)

In this work, effects of coolant chemistry, including concentrations of chloride ions and ethylene glycol and addition of various ions, on corrosion of 3003 Al alloy were investigated by electrochemical impedance spectroscopy measurements and scanning electron microscopy characterization. In chloride-free, ethylene glycol-water solution, a layer of Al-alcohol film is proposed to form on the electrode surface. With the increase of ethylene glycol concentration, more Al-alcohol film is formed, resulting in the increase in film resistance and charge-transfer resistance. In the presence of Cl- ions, they would be involved in the film formation, decreasing the stability of the film. In 50% ethylene glycol-water solution, the threshold value of Cl- concentration for pitting initiation is within ...

2010-01-01

390

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

British Library Electronic Table of Contents (United Kingdom)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...

2009-01-01

391

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

392

Combined inverse modeling approach and load duration curve method for variable nitrogen total maximum daily load development in an agricultural watershed  

British Library Electronic Table of Contents (United Kingdom)

Purpose Nonpoint sources (NPS) pollution has been an important cause for water quality impairment worldwide. To take the temporal variations of both NPS pollution and in-stream attenuation into consideration, an inverse modeling approach and the load duration curve (LDC) method were combined for variable nutrient total maximum daily load (TMDL) development. Methods Water quality and hydrological parameters were monitored monthly along the ChangLe River system in 2004?2008. The catchment NPS export load (EL) and TMDL for total nitrogen (TN) were estimated by the inverse format of an existing stream nutrient transport equation. The LDC method was used to describe the variability of EL, TMDL, requiring load (RLR) and percent (the ratio between the RLR and the EL, RPR) reduction, and then to s...

2011-01-01

393

Basement of the South China Sea Area: Tracing the Tethyan Realm  

British Library Electronic Table of Contents (United Kingdom)

Abstract: The basement of the South China Sea (SCS) and adjacent areas can be divided into six divisions (regions) - Paleozoic Erathem graben-faulted basement division in Beibu Gulf, Paleozoic Erathem strike-slip pull-apart in Yinggehai waters, Paleozoic Erathem faulted-depression in eastern Hainan, Paleozoic Erathem rifted in northern Xisha (Paracel), Paleozoic Erathem strike-slip extending in southern Xisha, and Paleozoic-Mesozoic Erathem extending in Nansha Islands (Spratly) waters. The Pre-Cenozoic basement in the SCS and Yunkai continental area are coeval within the Tethyan tectonic domain in the Pre-Cenozoic Period. They are formed on the background of the Paleo-Tethyan tectonic domain, and are important components of the Eastern Tethyan multi-island-ocean system. Three branches of t...

2011-01-01

394

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the ...

1990-07-01

395

The carbonate feedback system: interaction between stratigraphic accommodation, ecological succession and the carbonate factory; Le systeme de feed-back des carbonates: une interaction entre accomodation stratigraphique, succession ecologique et l`usine des carbonates  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the analysis of carbonate depositional systems, using high resolution sequence stratigraphy, studies the ratio between change in accommodation space and skeletal carbonate production. This approach establishes the concurrent change in nature of facies belts (expansion, retraction and type) and fossil communities, within the detailed time frame in accommodation. Carbonate production is generally considered to be a fairly simple function of environmental conditions such as climate and water depth. However, data from several case studies also show a covariance between change in stratigraphic architecture of carbonate systems (the seaward or landward stepping stacking patterns of stratigraphic units) and charge in facies. Case studies include Carboniferous algal mound development in the Paradox Basin (USA), Devonian stromatoporoid reef development in Alberta (Canada), and Cenomanian rudistid shoal development in ...

1996-12-31

396

Energy analysis of a solar pre-water heating system; Analise energetica de um sistema de pre-aquecimento solar de agua  

Energy Technology Data Exchange (ETDEWEB)

Several technological alternatives have been studied taking into consideration that one of the biggest problems of the electric power companies is to provide electric power during the peak consumption periods, which largest contribution to the increase of the demand comes from the residential sector, especially by the use of electric showers. One of the most promising alternatives is the pre-water heating system for reduced power showers, developed by Universidade de Campinas and Companhia Paulista de Forca e Luz. The goal of this system is basically to reduce demand during the peak periods, in order to avoid heavy investments by the electric power companies in generation, transmission and distribution of electric power directed to low acquisitive power customers, a sector in which the electric power price is not enough to recover such investments. The objective of this paper is to evaluate the total energy required in the ...

1996-12-31

397

Assessment of energy performance in the life-cycle of biogas production  

International Nuclear Information System (INIS)

Energy balances are analysed from a life-cycle perspective for biogas systems based on 8 different raw materials. The analysis is based on published data and relates to Swedish conditions. The results show that the energy input into biogas systems (i.e. large-scale biogas plants) overall corresponds to 20-40% (on average approximately 30%) of the energy content in the biogas produced. The net energy output turns negative when transport distances exceed approximately 200 km (manure), or up to 700 km (slaughterhouse waste). Large variations exist in energy efficiency among the biogas systems studied. These variations depend both on the properties of the raw materials studied and on the system design and allocation methods chosen. The net energy output from biogas systems based on raw materials that have high water content and low biogas yield (e.g. manure) is ...

2006-03-01

398

Water resources data for Oklahoma, water year 1992. Volume 2. Red River Basin. Water-data report (Annual), 1 October 1991-30 September 1992  

Energy Technology Data Exchange (ETDEWEB)

Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.

1993-04-01

399

Natural disaster risk analysis for critical infrastructure systems: An approach based on statistical learning theory  

Energy Technology Data Exchange (ETDEWEB)

Probabilistic risk analysis has historically been developed for situations in which measured data about the overall reliability of a system are limited and expert knowledge is the best source of information available. There continue to be a number of important problem areas characterized by a lack of hard data. However, in other important problem areas the emergence of information technology has transformed the situation from one characterized by little data to one characterized by data overabundance. Natural disaster risk assessments for events impacting large-scale, critical infrastructure systems such as electric power distribution systems, transportation systems, water supply systems, and natural gas supply systems are important examples of problems characterized by data overabundance. There are often substantial amounts of information ...

2009-04-15

400

Fiscal 1996 report on the results of the subsidy operation under the Sunshine Project on the development of a geothermal water use power plant, etc. Development of the binary cycle power plant (development of the measurement while drilling system for geothermal wells); 1996 nendo New Sunshine keikaku hojo jigyo seika hokokusho. Nessui riyo hatsuden plant nado kaihatsu (binary cycle hatsuden plant no kaihatsu (chinetsusei kussakuji kotei joho kenchi system no kaihatsu))  

Energy Technology Data Exchange (ETDEWEB)

The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. In the development ...

1997-03-01

401

Utilization of emulsified rapeseed oil in a direct injection diesel engine; Chokufunshiki diesel kikan deno nataneyu nyuka nenryo no riyo  

Energy Technology Data Exchange (ETDEWEB)

With an objective to use reproducible vegetable oil as a substitute fuel, studies were performed to use emulsified rapeseed oil at an optimal mixing ratio with water in a direct injection diesel engine. The experiment used a water cooled, lateral installation, single-cylinder, direct injection, four-cycle diesel engine, and the tested fuel used an emulsified rapeseed oil fuel with rapeseed oil added with water at a rate of 20% by weight. As a result of the experiment using the emulsified rapeseed oil, it was found that reducing the injection opening diameter smaller than the standard opening diameter improves the engine performance and simultaneously reduces concentrations of HC, CO and exhaust smoke. The optimal opening diameter was about 0.22 mm. Increasing the valve opening pressure reduced the NOx concentration, but increased the HC concentration. Using the emulsified rapeseed oil fuel accumulated more carbon below the ...

1994-09-30

402

Two-phase flow regime observations in a vertical hexagonal flow channel with and without a finned fuel bundle  

International Nuclear Information System (INIS)

Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, Real-Time Neutron ...

1990-12-10

403

Trace metal concentrations in estuaries and coastal regions  

Energy Technology Data Exchange (ETDEWEB)

Estuaries and coastal regions are highly variable in the physical and hydrographic conditions. As a result of heavy urbanization and industrialization of the head waters of most estuaries, there are substantial localized inputs of contaminants to the estuary. These factors combined with the flushing characteristics of individual estuaries to create relatively unique features that result in variation in the typical levels of trace metals for these systems. This makes intercomparison of the estuaries difficult. Comparability among estuaries becomes even more difficult when metals analyses are conducted without proper control of field and laboratory contamination, now firmly established in the trace metal analytical literature as a prerequisite for reliable marine trace metals analysis. This paper compares the concentrations of selected trace metal (Ag, Cd, Cu, Ni, Pb, and Zn) concentrations in the waters of several major ...

1994-12-31

404

Studies of the behaviour of technical chemicals introduced into the subsoil under modelled conditions  

International Nuclear Information System (INIS)

Because of the environmental hazard of organic solvents such as chlorinated or aromatic hydrocarbons, water soluble and biodegradable substitutes have come into use. It should be assessed how they affect soil and aquifer when spilled in leaks or accidents. This was simulated in a model system using methanol and percolation columns, one filled with material from the unsaturated subsurface and two with different materials from aquifers. The results reveal that a spill of the substitutes can also cause problems. In homogeneous soils and at long retention times until the substance reaches the aquifer, sorption and biological degradation are most likely to prevent contamination of the groundwater. When oxygen supply in the subsurface is insufficient, reducing conditions occur and sulphide is formed. The data show that much more methanol was eliminated than reflected by the consumption of electron acceptors. This indicates that sorption and anabolic ...

1993-04-01

405

Soil heterogeneity effects on O2 distribution and CH4 emissions from wetlands: In situ and mesocosm studies with planar O2 optodes and membrane inlet mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

The importance of soil heterogeneity for methane emission from a wetland soil is assessed by in situ point measurements of depth-specific O2 and CH4 concentrations and simultaneous soil CH4 fluxes at contrasting water levels. Profile measurements, and associated assumptions in their interpretation, were validated in a controlled mesocosm drainage and saturation experiment applying planar O2 optodes and membrane inlet mass spectrometry. Results show that peat soil is heterogeneous containing dynamic macropore systems created by both macrofauna and flora, which facilitate preferential flow of water, O2 and CH4 and vary temporally with changes in the moisture regime. The O2 content above the water table after drainage varied horizontally from 0 to 100% air saturation within few mm. Oxic zones...

2010-01-01

406

Safety analysis practices for the dense storage of RBMK spent fuel and improved technology for the long term storage of spent fuel in water pools  

International Nuclear Information System (INIS)

The paper discusses the safety problems connected with the conversion to dense storage of RBMK-1000 spent fuel in reactor cooling pools and independent storage facilities. Recourse to dense storage has been made for a number of reasons, among which are the absence of spent fuel shipments from the nuclear power plant site, prolongation of storage time and a partial change in storage conditions. Increasing the storage density per unit volume of the storage facility and turning to new technical procedures (as against the basic design) call for further investigation of safety problems. The safety assessment of the dense storage mode includes: (1) Selecting a list of initiating events for design basis and unforeseeable accidents; (2) Assessing dense storage safety under normal as well as design basis accident conditions; (3) Safety analysis and development of measures to compensate for unforeseen accidents. Based on the studies performed, suggestions have been advanced concerning ...

1995-08-01

407

Rationale for chemical control of feedwater and boiler water. Volume 1. Concentration models. Final report  

Science.gov (United States)

Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying out the base of the ...

1984-01-01

408

Properly synchronized measurements of droplet sizes for high-pressure intermittent coal-water slurry fuel sprays  

Energy Technology Data Exchange (ETDEWEB)

Experiments were completed to study intermittent coal-water slurry (CWS) fuel sprays injected from an electronically-controlled accumulator injector system. A new synchronization technique was developed using the light extinction signal as a triggering source for the data taking initiation with a laser diffraction particle analyzing (LDPA) technique. This technique allowed measurement of SMDs near the spray tip where the light extinction was low and the data were free from the multiscattering bias. Coal-water slurry fuel with 50% coal loading in mass containing 5 {mu}m mass median diameter coal particulates was considered. A correlation of the SMD with the injection conditions was determined which should show a satisfactory agreement with the measured SMD data. The spray SMD showed an increase with the distance of the axial measurement location and with the ambient gas density, and showed a decrease with increasing ...

1993-12-31

409

Primary coolant depressurization facility  

Energy Technology Data Exchange (ETDEWEB)

In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible ...

1992-10-14

410

Obsidians and tektites: Natural analogues for water diffusion in nuclear waste glasses  

Energy Technology Data Exchange (ETDEWEB)

Projected scenarios for the proposed Yucca Mountain repository include significant periods of time when high relative humidity atmospheres will be present, thus the reaction processes of interest will include those known to occur under these conditions. The ideal natural analog for the proposed Yucca Mountain repository would consist of natural borosilicate glasses exposed to expected repository conditions for thousands of years; however, the prospects for identifying such an analog are remote, but an important caveat for using natural analog studies is to relate the reaction processes in the analog to those in the system of interest, rather than a strict comparison of the glass compositions. In lieu of this, identifying natural glasses that have reacted via reaction processes expected in the repository is the most attractive option. The goal of this study is to quantify molecular water diffusion in the natural analogs obsidian and tektites. ...

1991-11-01

411

Macrofouling control in nuclear power plants  

International Nuclear Information System (INIS)

Macrofouling of cooling-water systems is one of the more significant and costly problems encountered in the nuclear power industry. Both marine and freshwater macroinvertebrates can be responsible for losses in plant availability because of plugged intakes and heat transfer equipment. There is a greater diversity of macrofouling organisms in marine waters than in fresh waters. Marine macrofouling organisms include barnacles, mollusks, bryozoans, and hydroids. Barnacles are crustaceans with feathery appendages, which allow them to attach to a variety of surfaces. They are a major cause of severe macrofouling because they can remain attached even after death. The major freshwater macrofouling organisms include the Asiatic Clam (Corbicula fluminea) and the newest freshwater macrofouler, the Zebra Mussel (Dreissena polymorpha). The introduction of the Zebra Mussel into the Great Lakes has created economic ...

1991-11-10

412

Long-term corrosion study at nuclear power plant Bohunice (Slovakia)  

International Nuclear Information System (INIS)

Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original 'Bohunice' design in period 1994-1998. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Moessbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Moessbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filter deposits. The corrosion of new feed water pipelines system (from austenitic steel) in combination to innovated operation regimes goes dominantly to magnetite. The hematite presence is mostly on the internal surface of steam generator body and its concentration increases towards the top ...

2010-03-01

413

Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor  

Energy Technology Data Exchange (ETDEWEB)

Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel design, the heat exchanger efficiency ...

2005-07-01

414

Experience on resin pyrolysis  

International Nuclear Information System (INIS)

The Swedish State Power Board has together with Nukem, Hanau, West-Germany carried out pyrolysis o powder resins in a pilot plant with a capacity of about 30 kg/hr. The pyrolysis reactor with its afterburner and offgas scrubber system has been operated under steady state condition. About 2200 kg resins have been pyrolysed under November-December 1983 and the decontamination factor for Cs has been measured. Solidification of the residues from the pyrolysis reactor and scrubber water solutions has been carried out and various recipes with cement have been tested. The pyrolysis process has high decontamination factors and no offgas problems as the operating temperature of the reactor is Low. The residues from the reactor are chemically dead and can not cause swelling problems. Compared with a normal cementation process the final waste volume will be reduced with a factor of 4 if also the scrubber water after neutralization is ...

415

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, loss of the GDCS pool ...

1990-10-29

416

Electron spin resonance probe for the solvation of ionomer membranes and other microscopically heterogeneous systems. Cu[sup 2+] in nafion, sephadex and silica gel  

Energy Technology Data Exchange (ETDEWEB)

Cu[sup 2+] is a sensitive electron spin resonance (ESR) probe for the penetration of various polar solvents in membranes made of Nafion and as an indicator for the replacement of one solvent by another. The ESR parameters (g and [sup 63]Cu hyperfine tensors) can be translated into a structure of the solvent around the cation. The replacement of a solvent in the membrane by another depends on the polarity of the two solvents. The solvent with the largest dielectric constant, N-methylformamide (NMF), can be replaced by water but not by methanol or acetonitrile (dielectric constants 182, 78.5, 32.7, and 37.5, respectively). Preferential solvation of the cation by water in three water/acetonitrile mixtures (9:1, 1:1, and 1:9 by volume) in contact with silica gel, Sephadex, and Nafion has been observed in various degrees. Nafion is most selective, followed by Sephadex and by silica gel. The selectivity appears to be related to ...

1992-01-01

417

Effect of dissolved oxygen, hydrazine and pH outside the crevice on the galvanic corrosion of support plate alloys  

International Nuclear Information System (INIS)

A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven specimens in the lower ...

1985-03-01

418

Effect of dissolved oxygen on denting corrosion  

International Nuclear Information System (INIS)

The following conclusions are drawn from the study of the effects of dissolved oxygen on corrosion denting: 1) Following the ingress of fresh-water contamination into a PWR boiler, an acidic chloride solution can be formed in the crevice between tube and tube support plate when an oxidant such as dissolved oxygen or copper ions is present in the boiler water. 2) In the absence of copper, very high levels of dissolved oxygen and neutral chloride are necessary to initiate corrosion. 3) When copper is present in the feed system, sufficient copper ions to initiate corrosion within the crevice are released when the chloride concentration is 0.8 mg/kg and probably also at lower chloride values. Corrosion initiation however may require prior exposure of the copper to dissolved oxygen and can be suppressed by pretreatment with hydrazine. 4) The effect of dissolved oxygen on corrosion already occurring was not explored; neither was ...

1985-03-01

419

Development of generalized boiling transition analysis methodology applicable to a wide variety of BWR-type fuel bundle geometry -Mater plan and status of first year-  

Energy Technology Data Exchange (ETDEWEB)

As a three-year joint university-industry effort, development of a generalized boiling transition analysis method has been started in 2002 aiming at enhanced capabilities of subchannel analysis for a wide variety of BWR-type fuel bundle geometry from ordinary BWR to tight lattice fuel bundles. For this purpose, five dominant factors affecting boiling transition phenomena have been identified on which our efforts of experimentation and numerical analyses are focused. In this report, as the first-year achievement, we will describe a master plan of the development and contents for experimental approaches to construct thermal-hydraulic databases. The databases will be utilized for the developments of constitutive equations to describe the basic characteristics of the elementary processes. The planned experiments are divided into two groups. One is air-water experiments at atmospheric pressure, and the other is steam-water experiments up to 1 MPa. ...

2003-07-01

420

Development of generalized boiling transition analysis methodology applicable to a wide variety of BWR-type fuel bundle geometry -Mater plan and status of first year-  

International Nuclear Information System (INIS)

As a three-year joint university-industry effort, development of a generalized boiling transition analysis method has been started in 2002 aiming at enhanced capabilities of subchannel analysis for a wide variety of BWR-type fuel bundle geometry from ordinary BWR to tight lattice fuel bundles. For this purpose, five dominant factors affecting boiling transition phenomena have been identified on which our efforts of experimentation and numerical analyses are focused. In this report, as the first-year achievement, we will describe a master plan of the development and contents for experimental approaches to construct thermal-hydraulic databases. The databases will be utilized for the developments of constitutive equations to describe the basic characteristics of the elementary processes. The planned experiments are divided into two groups. One is air-water experiments at atmospheric pressure, and the other is steam-water experiments up to 1 MPa. ...

2003-10-05

421

Crud behaviors and water chemistry in nuclear reactors  

International Nuclear Information System (INIS)

The deposit of radioactive corrosion products in the cooling systems of nuclear reactors becomes a serious problem for the personnel of facilities. Crud has an important role in the process of depositing radioactive corrosion products. The main components of crud are hematite, magnetite, nickel ferrite and so on, and the particles of these oxide compounds are distributed in water. Most of the behavior of crud are still not known. As for the mechanism of the production of crud, the Potter-Mann model has been proposed. However, the precipitation process of iron ions in water is unknown. The crud is defined as the particles filtered by 0.45 micrometer millipore filters. However, it is not known whether there are crud particles smaller than this size. The crud particles can be adsorbed on the filters by the surface electrochemical interaction. The adsorption of cations to crud particles was studied. The adhesion of crud ...

422

Corrosion failure and its prevention in light water reactor power plants  

Energy Technology Data Exchange (ETDEWEB)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

1988-01-01

423

Corrosion failure and its prevention in light water reactor power plants  

International Nuclear Information System (INIS)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

424

Biological and chemical evaluation of sewage water pollution in the Rietvlei nature reserve wetland area, South Africa  

International Nuclear Information System (INIS)

Macroinvertebrate communities in Rietvlei nature reserve wetland area and their relationship with water quality were studied with the aim to evaluate their use as potential indicators of pollution. Sampling locations were selected to include outlets from swage effluent, agricultural and informal residential runoff. A large increase in nutrient concentrations was observed downstream from discharged treated sewage with an associated decrease in species richness. Bioassays performed included: Daphnia magna, Hydra attenuate, Lactuca sativa, Allium cepa and Pyxicephalus adspersus. The highest percentage of lethality response to a screen (100% concentration) of sampled wetland water by test specimens were observed at the point source input of the Hartbeespoort treated sewage plant. Data generated from the AUSRIVAS method and multitrophic level bioassays revealed the deterioration of the wetland possibly due to factors such as increasing urbanization, ...

2008-11-01

425

An engineering approach to solid waste collection system: Ibadan North as case study  

International Nuclear Information System (INIS)

This research centered on finding and perfecting methods of collection and disposal of refuse in Ibadan North Local Government Areas. The methodology used included questionnaire administration, personal interviews, field reconnaissance, and biochemical tests of water samples, all aimed at providing useful data for the design of effective methods of collecting and disposing refuse. The local government area was divided into three classes based on resident income: a high-income area (Bodija Avenue, etc.), a medium-income area (Sanngo, Oluyole, etc.), and a low-income area (Beere, Adeoyo, etc.). The research outcomes revealed that the waste generation rate for the local government ranged from 0.2 to 0.33 kg/cap/day and waste density ranged from 172.41 to 217.61 kg/m"3. Water analyses showed that the chloride, manganese, lead, and cadmium levels in water from low-income areas were above the WHO standard. The refuse generated in ...

426

Abrasive waterjet cutting of high purity uranium metal: Topical report  

Science.gov (United States)

The Abrasive Waterjet Cutting process was evaluated to determine if the equivalent could be utilized for cutting uranium metal at the Feed Materials Production Center (FMPC). In the process, a thin stream of ultrahigh pressure water carried grit material through a designated piecepart. In order to be acceptable for use at the FMPC, the equipment must be cost effective, minimize waste, and be adaptableto operating in an enclosure, and improve health and safety conditions. Observation of the cutting process showed that health and safety aspects could be optimized with an enclosed ventilated system. Also the equipment can be easily automated. The cutting action produced sparks similar to the sparks caused by a grinding operation. The sparks are captured in a water container under the workpiece that not only catches the sparks, but also serves to dissipiate the stream of water and residues produced by the ...

1988-01-01

427

The all-electric drill ship  

Energy Technology Data Exchange (ETDEWEB)

Oil, in various forms, has been used for thousands of years and has even been recommended as a medicinal product. Starting in the mid-19. century, however, mineral oil production became an economic, political, social and scientific gold mine. Subterranean and offshore drilling rigs have created colossal fortunes among multinationals and made certain nations extremely wealthy. Starting in the 1920's, oil companies began to explore the possibilities of undersea drilling, but it was only in 1947 that the first offshore drilling rig was set up. With three-quarters of the planet covered by water, it was inevitable that oil companies would turn to offshore drilling - especially as sub-sea oil fields may cover as much as 84 million square kilometres. Drilling rigs now go deeper than ever and are able to operate in up to 3000 meters water depth. This paper will present the technical merits of two similar all-electric drill-ships ...

2000-07-01

428

Increased Mercury Bioaccumulation Follows Water Quality Improvement  

International Nuclear Information System (INIS)

Changes in physical and chemical characteristics of aquatic habitats made to reduce or eliminate ecological risks can sometimes have unforeseen consequences. Environmental management activities on the U.S. Dept. of Energy reservation in Oak Ridge, Tennessee,have succeeded in improving water quality in streams impacted by discharges fi-om industrial facilities and waste disposal sites. The diversity and abundance of pollution-sensitive components of the benthic macroinvertebrate communities of three streams improved after new waste treatment systems or remedial actions reduced inputs of various toxic chemicals. Two of the streams were known to be mercury-contaminated from historical spills and waste disposal practices. Waterborne mercury concentrations in the third were typical of uncontaminated systems. In each case, concentrations of mercury in fish, or the apparent biological availability of mercury increased over the ...

429

Technical considerations associated with waste-to-energy systems  

Energy Technology Data Exchange (ETDEWEB)

The average American generates four pounds of solid waste per day, yet increasing constraints are being placed on the ability of municipalities to handle waste disposal. Most cities face a scarcity of acceptable landfill sites and conventional incineration and landfill methods have come under strict air, water and soil pollution standards. City administrators are being encouraged to select from a variety of proposed technologies that supplant traditional waste disposal methods, some of which offer the promise of revenues from energy and resource recovery. The problem is to select from available near-term technologies those systems that will fit into a city's long-term solid-waste management program. Broadly, waste-to-energy recovery systems now available to cities may be classified as combustion, pyrolysis, biodegradation, and mechanical front-end systems. It is important to notice that ...

1981-01-01

430

Supporting Thermal Hydraulic Calculations for the SGTR Event Tree of SMART Level 1 PSA  

International Nuclear Information System (INIS)

SMART (System integrated Modular Advanced ReacTor) , is under development at the Korea Atomic Energy Research Institute (KAERI). SMART is an integral type pressurized water reactor which contains a pressurizer, 4 reactor coolant pumps (RCPs), and 8 steam generator cassettes(S/Gs) in a single reactor vessel. This reactor has substantially enhanced its safety with an integral layout of its major components, 4 trains of safety injection system (SIS), and an adoption of 4 trains of passive residual heat removal system (PRHRS) instead of an active auxiliary feedwater system . The thermal power is 330 MWth. During the conceptual design stage, a preliminary PSA was performed. PSA results identified that a steam generator tube rupture (SGTR) is one of the most important initiating events which results in a high core damage frequency. Clear understanding of accident progression with various ...

2010-10-01

431

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving ...

1996-02-01

432

Solar expriment begins at Atlanta school. [George A. Towns Elementary School  

Science.gov (United States)

The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind conditions will be recorded. The inlet ...

1976-03-01

433

Phosphorous adsorption and precipitation in a permeable reactive wall: Applications for wastewater disposal systems  

Energy Technology Data Exchange (ETDEWEB)

A permeable reactive mixture has been developed using low cost, readily available materials that is capable of providing effective, long-term phosphorous treatment in areas impacted by on-land wastewater disposal. The reactive mixture creates a geochemical environment suitable for P-attenuation by both adsorption and precipitation reactions. Potential benefits include significant reductions in phosphorous loading to receiving groundwater and surface water systems, and the accumulation of P-mass in a finite and accessible volume of material. The mixture may be applied as a component within surface treatment systems or in subsurface applications such as horizontal or vertical permeable reactive walls. The mixture averaged > 90% treatment efficiency over 3.6 years of continuous-flow laboratory column experiments. The mixture was further evaluated at the pilot-scale to treat municipal wastewater, and the field-scale to treat ...

1997-12-31

434

Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems  

Energy Technology Data Exchange (ETDEWEB)

Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. (Author).

1992-11-01

435

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the ...

1986-01-01

436

Innovative coke oven gas cleaning system for retrofit applications. Quarterly environmental monitoring report No. 1, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia removal ...

1992-08-24

437

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia removal ...

1992-08-24

438

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The ...

1984-09-01

439

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The ...

1984-01-01

440

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill inspection and manipulation requirements were developed for the ...

1994-12-31

441

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and ...

2005-11-23

442

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling ...

2007-07-01

443

Safe Water in an Emergency  

Medline Plus

English - Safe Water in an Emergency Click to Stop Video Click to Start Video To Listen to ...

444

Isothermal heat measurements of TBP-nitric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

Net heats of reaction were measured in an isothermal calorimeter for both single phase (organic) and two phase (organic and aqueous) TBP/HNO{sub 3} reacting solutions at temperatures above 100 C. The oxidation rate constant was determined to be 5.4E-4 min{sup {minus}1} at 110 C for an open ``vented`` system as compared to 1.33 E-3 min{sup {minus}1} in the closed system. The heat released per unit material oxidized was also reduced. The oxidation in both phases was found to be first order in nitric acid and pseudo-zero order in butylnitrate and water. The hydrolysis (esterification) rate constant determined by Nichols` (1.33E-3 min{sup {minus}1}) fit the experimental data from this work well. Forced evaporation of the volatile components by the product gases from oxidation resulted in a cooling mechanism which more than balanced the heat from the oxidation reaction in the two-phased systems. Rate ...

1994-12-16

445

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term monitoring of the operating conditions, (3) measurement of ...

2001-03-01

446

Building a Construction Curriculum for Your School District  

Science.gov (United States)

Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a ...

2010-06-01

447

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 {ell}/s (1 ft{sup 3}/min). The water flow rate was varied between 0 and 3.78 {ell}/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6} n/cm{sup 2}{center_dot}s{sup {minus}1} directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm ...

1995-09-01

448

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6}n/cm{sup 2}/s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of ...

1992-12-31

449

Void fraction measurements using neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 ell/s (1 ft"3/min). The water flow rate was varied between 0 and 3.78 ell/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10"6 n/cm"2#centre dot#s"-"1 directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support ...

1995-01-01

450

Three-phase flow in heterogeneous wettability porous media; Deplacements triphasiques en milieux poreux de mouillabilite heterogene  

Energy Technology Data Exchange (ETDEWEB)

Better understanding and modelling of three-phase flow through porous media is of great interest, especially for improved oil recovery methods such as gas injection processes. Early theoretical and experimental studies have already demonstrated that the wettability characteristics of the solid surface and the spreading characteristics of the fluid system hold the key roles. This observation is confirmed by our theoretical results using DLP theory on the stability and the thickness of static oil films. In most of the works related to three-phase flow processes, homogeneous wettability is assumed. There exist only a few studies demonstrating the tremendous impact of the wettability heterogeneities on gas injection. The objective of the present work is twofold: to demonstrate the effect of small scale wettability heterogeneities on gas injection efficiency, and to develop a tool to predict this impact for various patterns and spatial distributions. To this end an ...

1998-11-26

451

Instrumentation for monitoring and control of water chemistry for light-water-cooled nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: radioactive nuclides ({sup 60}Co, {sup 58}Co, {sup 131}I, etc.), ...

2010-05-15

452

Environmental mitigation for SCC initiation of BWR core internals by hydrogen injection during start-up  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen injection into the reactor water has been applied to many BWR power stations. Since hydrogen injected accelerates recombination of oxidant generated by water radiolysis, oxidant concentration, such as dissolved oxygen concentration in reactor water can be reduced. As the result of the reduction of oxidant concentration, Electrochemical Corrosion Potential (ECP) at the surface of structural material can be lowered. Lowered ECP moderates Stress Corrosion Cracking (SCC) sensitivity of structural materials, such as stainless steels. As usual, hydrogen injection system begins to work after the plant start-up is finished, when the condition of normal operation is established. Accordingly, Hydrogen Water Chemistry (HWC) does not cover all the period of plant operation. As far as SCC crack growth is considered, loss of HWC during plant start-up does not result in significant crack ...

2004-07-01

453

Multielement determination of heavy metals in water samples by continuous powder introduction microwave-induced plasma atomic emission spectrometry after preconcentration on activated carbon  

International Nuclear Information System (INIS)

A novel continuous powder introduction microwave-induced plasma atomic emission spectrometry method (CPI-MIP-AES) has been developed for trace determination of metals in ground and tap water samples after preconcentration on activated carbon. The experimental setup consisted of integrated rectangular cavity TE_1_0_1 and vertically positioned plasma torch. The technical arrangement of the sample introduction system has been designed based on the fluidized bed concept. The satisfactory signal stability required for sequential analysis was attained owing to the vertical plasma configuration, as well as the plasma gas flow rate compatibility with sample introduction flow rate. The elements of interest (Cd, Cu, Cr, Fe, Mn, Pb, Zn) were preconcentrated in a batch procedure at pH 8-8.5 after addition of activated carbon and then, after filtering and drying of the activated carbon suspension, introduced to the MIP by the CPI ...

2005-03-31

454

High resolution sequence stratigraphy of Miocene deep-water clastic outcrops, Taranaki coast, New Zealand  

Energy Technology Data Exchange (ETDEWEB)

Approximately 700m of deep water clastic deposits of Mt. Messenger Formation are superbly exposed along the Taranaki coast of North Island, New Zealand. Biostratigraphy indicates the interval was deposited during the time span 10.5-9.2m.y. in water depths grading upward from lower bathyal to middle-upper bathyal. This interval is considered part of a 3rd order depositional sequence deposited under conditions of fluctuating relative sea-level, concomitant with high sedimentation rates. Several 4th order depositional sequences, reflecting successive sea-level falls, are recognized within the interval. Sequence boundaries display a range of erosive morphologies from metre-wide canyons to scours several hundred metres across. All components of a generic lowstand systems tract--basin floor fan, channel-levee complex and progading complex--are present in logical and temporal order. They are repetitive through the interval, with ...

1995-08-01

455

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator tubes can potentially ...

1996-06-01

456

Use of explosive quick depressurization valves in the SBWR project. Dynamic loads induced by their operation  

International Nuclear Information System (INIS)

In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other ...

457

Start-up control system and vessel for LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A reflux condensing start-up system includes a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a ...

1987-01-01

458

Solidification of DOE problem wastes  

Energy Technology Data Exchange (ETDEWEB)

Sodium nitrate waste has been successfully solidified in two types of polymeric materials: polyethylene, a thermoplastic material, and polyester styrene (PES), a thermosetting material. Waste form property evaluation tests such as ANS 16.1 leaching test and compressive strength measurements were performed on the waste forms containing various amounts of sodium nitrate. A single-screw extruder was employed for incorporating dry waste into polyethylene at its melt temperature of 120/sup 0/C to produce a homogenous mixture. Results of the leaching test for polyethylene waste forms containing 30, 50, 60 and 70 wt% sodium nitrate are presented as cumulative fraction leached and leaching indices ranging from 11 to 7.8. Two PES systems are discussed. The first is for solidification of dry salt wastes and the second is a water extendible system that is compatible with wet waste streams. Leaching data for PES and ...

1986-01-01

459

Results of two-phase natural circulation in hot-leg U-bend simulation experiments  

Energy Technology Data Exchange (ETDEWEB)

In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed using two different thermal-hydraulic loops. The main focus of the experiment was the two-phase flow behavior in the hot-leg U-bend typical of BandW LWR systems. The first group of experiments was carried out in the nitrogen gas-water adiabatic simulation loop and the second in the Freon 113 boiling and condensation loop. Both of the loops have been designed as a flow visualization facility and built according to the two-phase flow scaling criteria developed under this program. The nitrogen gas-water system has been used to isolate key hydrodynamic phenomena such as the phase distribution, relative velocity between phases, two-phase flow regimes and flow termination mechanisms, whereas the Freon loop has been used to study the effect of ...

1987-01-01

460

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the feedback signal and the ...

1993-12-01

461

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of diversion plates and chutes which directed ...

1992-09-01

462

Mullite long fibres prepared by sol-gel method using water solvent systems  

Energy Technology Data Exchange (ETDEWEB)

Mullite long fibres, which are a candidate for high temperature applications were prepared by sol-gel method from water solvent systems. They were synthesized from three different combinations of raw materials as follows: (1):Al(O{sub 1}C{sub 3}H{sub 7}){sub 3}, Al-nitrate and Si(OC{sub 2}H{sub 5}){sub 4} (TEOS), (2):Al metal, Al-chloride and TEOS, (3):Al metal, Al-nitrate and TEOS. In the methods (1) and (2), very fine SiO{sub 2} aerosol particles were also used partially replacing TEOS. The prepared solutions were condensed and examined the spinability by a hand drawing method. Dense and crack free mullite fibres were prepared from the methods (1) and (3) by firing up to 1100 C. Whereas the fibres prepared from the method (2) were less SiO{sub 2} than mullite composition and were porous by the firing due to evaporation of residual Cl ions at high temperature. (orig.) 10 refs.

1997-12-31

463

Improvement of wood quality used in Syria by irradiation polymerization  

International Nuclear Information System (INIS)

Wood plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, and with Okoume (aucoumea klaineana pierre) imported to Syria in large quantities. Three monomer systems; acrylamide, butylmethacrylate, and styrene were used. polymerization was induced at various radiation doses (10, 20, and 30 kGy) to study the role of radiation doses using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength or tensile strength of the obtained wood polymer composites (WPC) were studied. The effect of the additives, sulfuric acid (H"+), N-vinyl pyrrolidone (NVP), trimethyolpropane triacrylate (TMPTA), urea (U), lithium nitrate (LiNo_3), copper sulfate (CuSO_4) and co-additives on monomer system polymerization were also investigated. Methanol, water and water/methanol mixtures were used as the swelling agents. In general, the use of ...

2010-04-01

464

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome ...

1992-01-01

465

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome ...

1992-11-15

466

Corrosion of support materials  

International Nuclear Information System (INIS)

Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or corrosion penetrations utilized, average bulk water chloride concentrations, pilling bedworth ratios, pot and model boilers data are equivalent, heat flux not significantly ...

1985-03-01

467

Competition advantage by utilizing the gross calorific value-high potential for the local heat supply; Wettbewerbsvorsprung durch Brennwertnutzung. Hohes Potential bei der Nahwaermeversorgung  

Energy Technology Data Exchange (ETDEWEB)

The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter Brennwerttechnik ihre Kosten senken und einen zusaetzlichen Beitrag zum Umweltschutz leisten. Mit dem richtigen Brennwertkessel amortisieren sich ...

1999-01-01

468

Assessing the Significance of Above- and Belowground Carbon Allocation of Fast- and Slow-Growing Families of Loblolly Pine - Final Report  

Energy Technology Data Exchange (ETDEWEB)

During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between ...

2001-03-01

469

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

470

An analysis of PZR and related system design features for KNGR  

Energy Technology Data Exchange (ETDEWEB)

The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were higher and lower, ...

1995-12-01

471

Carbon Capture and Water Emissions Treatment System (CCWESTRS) at Fossil-Fueled Electric Generating Plants  

Energy Technology Data Exchange (ETDEWEB)

The Tennessee Valley Authority (TVA), the Electric Power Research Institute (EPRI), and the Department of Energy-National Energy Technologies Laboratory (DOE-NETL) are evaluating and demonstrating integration of terrestrial carbon sequestration techniques at a coal-fired electric power plant through the use of Flue Gas Desulfurization (FGD) system gypsum as a soil amendment and mulch, and coal fly ash pond process water for periodic irrigation. From January to March 2002, the Project Team initiated the construction of a 40 ha Carbon Capture and Water Emissions Treatment System (CCWESTRS) near TVA's Paradise Fossil Plant on marginally reclaimed surface coal mine lands in Kentucky. The CCWESTRS is growing commercial grade trees and cover crops and is expected to sequester 1.5-2.0 MT/ha carbon per year over a 20-year period. The concept could be used to meet a portion of the timber ...

2005-08-30

472

Understanding and protecting steam generator materials  

Science.gov (United States)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-01-01

473

Understanding and protecting steam generator materials  

International Nuclear Information System (INIS)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-11-16

474

UK's Sizewell inquiry; funny how time slips away  

Energy Technology Data Exchange (ETDEWEB)

Comments are made on the Public Inquiry into CEGB's proposal to construct a pressurized water reactor (PWR) at Sizewell, UK. Aspects discussed include: time elapsed and its possible effect on the result; economics of nuclear power plants compared with coal-fired power plants; changes in real sterling/dollar exchange rates; effect of mineworkers' strike; the UK electric power generating system; AGR reactors compared with PWR reactors; extension of Magnox reactor life; radioactive waste management; political decisions.

1985-03-01

475

The river Elbe. A case study for the ecological and economical chain of sediments  

Energy Technology Data Exchange (ETDEWEB)

Industrial activities in the river basin of the Elbe have a very long tradition, and have been resulting in the contamination of sediments for centuries. Contamination lasted until the fall of the iron curtain; since then, the situation has improved significantly. In the transition zone between freshwater systems and the marine environment, ports like Hamburg still have to bear this burden of history. An overall (contaminated) management strategy should be developed in the context of the European Water Framework Directive with the emphasis on source control. (orig.)

2002-07-01

476

Solidification of problem wastes: Annual progress report, October 1985-September 1986  

Energy Technology Data Exchange (ETDEWEB)

This report describes initial work on the development of solidification systems for sodium nitrate waste and compacted waste. Sodium nitrate waste has been solidified in three types of materials: polyethylene, polyester-styrene (PES), and latex cement. Evaluations of the properties of the waste form, such as the ANS 16.1 leaching test, water immersion test and compressive strength measurements were performed on the waste forms containing various amounts of sodium nitrate. 9 refs., 9 figs., 7 tabs.

1987-02-01

477

Solid-state ozone synthesis by energetic ions  

International Nuclear Information System (INIS)

We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.

1999-08-02

478

Scientific reference on the long time evolution of spent fuels; Referentiel scientifique sur l'evolution a long terme des combustibles uses  

Energy Technology Data Exchange (ETDEWEB)

This report is published in the framework of the 1991 French law for the nuclear waste management. The state of the art reported here concerns the long term evolution of spent fuel in the various environmental conditions corresponding to dry storage and geological disposal: closed system, air and water saturated medium. This review is based on the results of the french PRECCI project (Research Program on Long term Evolution of Spent Nuclear Fuel) and on literature data. (authors)

2005-03-15

479

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

480

Proceedings of the Canadian Society for Bioengineering CSBE/SCGAB 2009 annual general meeting and technical conference  

Energy Technology Data Exchange (ETDEWEB)

This conference was attended by experts on current issues in engineering of an urban ecosystem, composting, biofuels and green energy. The meeting provided a forum to discuss advances in the application of engineering principles and practices dealing with biological systems for the production of food, bioproducts and energy. The discussions focused on engineering practices in agriculture, forestry, bioresources, biochemistry and biosystems. The 7 technical sessions of the conference were entitled: aquaculture; safety and training; bioprocessing; energy production and biofuels; environment and ecology; soil and water; and development of technologies. The conference feature 58 presentations, of which 9 have been catalogued separately for inclusion in this database. refs., tabs., figs.

2009-07-01

481

Performance optimization of the humidification?dehumidification desalination process using mathematical programming  

British Library Electronic Table of Contents (United Kingdom)

In this paper the humidification?dehumidification desalination process is studied and its performance optimized using mathematical programming. An advantage of this method is consideration of the simultaneous effect of various parameters on process performance. An NLP system model is solved for three objective functions: minimization of specific thermal energy consumption, maximization of productivity and maximization of condenser heat recovery. The solutions have been improved especially from a productivity point of view in comparison with previous studies. The productivity objective function leads to the best solution if there is no limitation for the humidifier inlet water temperature. Otherwise, the specific energy objective function seems to be better than others. In the next step the...

2009-01-01

482

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

483

Indoor radon pollution: Control and mitigation. June 1978-December 1989 (Citations from the NTIS data base). Report for June 1978-December 1989  

International Nuclear Information System (INIS)

This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.).

484

Geothermal resource assessment of the New England states  

Energy Technology Data Exchange (ETDEWEB)

With the exception of Sand Springs in Williamstown, Massachusetts, there are no identifiable hydrothermal geothermal resources in the New England region. The radioactive plutons of the White Mountains of New Hampshire do not, apparently, contain sufficient stored heat to make them a feasible target for an induced hydrothermal system such as exists at Fenton Hill near Los Alamos, New Mexico. The only potential source of low grade heat is the large volume of ground water contained within the unconsolidated sediments related to the Pleistocene glaciation of the region. During the course of the survey an unusual and unexplained thermal anomaly was discovered in St. Johnsbury, Vermont, which is described.

1982-01-01

485

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions, Second Edition  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-05-01

486

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-02-01

487

Effect of tetracycline hydrochloride treatment on the critical thermal maximum of common shiners  

Energy Technology Data Exchange (ETDEWEB)

The transfer of fish from field to laboratory facilities or their propagation in closed or restricted systems frequently results in bacterial infection and ultimately large-scale mortality. In attemps to alleviate this problem, we have added tetracycline hydrochloride to the water prophylactically (pretreating tanks before wild fish were added) and therapeutically (treating tanks after bacterial outbreaks were detected.) In the present study, we examined the effect of tetracyline hydrochloride on the critical thermal maximum (CTM) of the common shiner (Notropis cornutus).

1980-01-01

488

DWPF Melter No.2 Prototype Bus Bar Test Report  

Energy Technology Data Exchange (ETDEWEB)

Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.

2003-03-26

489

Computational Chemistry Study of Solvents for Carbon Dioxide Absorption  

Energy Technology Data Exchange (ETDEWEB)

Absorption with aqueous amine solvents is at present the most viable technology for CO{sub 2} capture. While this is a proven technology, efforts are ongoing to improve it in order to make it a more attractive technology for large scale use to reduce CO{sub 2} emissions. Finding solvents with better properties is one approach to improving the technology. In this thesis methods in computational chemistry are used to improve the understanding of the chemistry of CO{sub 2} absorption in amine-water systems. The work is also intended to provide models that can be used to predict the performance of new solvents. Such predictive models are intended to facilitate the screening for new solvents

2005-08-15

490

Bring fresh ideas to boiler startup procedures  

Energy Technology Data Exchange (ETDEWEB)

This article describes innovations in new-boiler startups, based on experiences at United Development Group`s 50-MW Niagra cogeneration facility, Niagra Falls, NY. The plant comprises: a circulating coal fluidized bed boiler supplying steam to a nearby factory and electricity to the grid. Before operation the system was flushed with demineralized water, and the boiler degreased, the steam blow relied on a new procedure involving a continuous flow of steam. Startup was then initiated, following manufacturers heatup rate and soak times closely. After startup boiler tube sections were checked, and cleaned if necessary. 1 fig.

1996-05-01

491

Biomass production in Florida  

Energy Technology Data Exchange (ETDEWEB)

Florida posseses climatic, land, and water resources favorable for abundant biomass production. Therefore, a statewide program has been initiated to determine adapted species for the available array of production sites. Plant resources under investigation include woody, aquatic, grasses, hydrocarbon, and root crop species. The goal is to produce a continuous stream of biomass for the various biofuel conversion options. Preliminary yields from energy cropping experiments range from about 10 to nearly 90 metric tons per hectare per year, depending on the crop and the production systems employed. (Refs. 15).

1981-08-01

492

Australasia floating production storage offloading`s (F.P.S.O.) push  

Energy Technology Data Exchange (ETDEWEB)

Floating Production, Offshore Storage and Offloading (FPSO) of hydrocarbons is not new. However, offshore crude oil development has to face the increasing need of the geopolitical interests to develop smaller or difficult reservoir in remote areas in deeper water and harsher environment. Such a trend can only be sustained if the offshore technology provides the right tools at the right time and at an acceptable price. This article will attempt to describe the relative merits of FPSO systems and discuss its main components. An overview of the present world situation shows the excellent performance of the FPSO with the type of development strategy undertaken in P.R.C.

1993-12-31

493

Atomic power of Germany and ecology  

International Nuclear Information System (INIS)

The NPPs safety system in Germany is discussed. It is shown that there exists no threat for the German NPPs at the peace times. They release insignificant quantities of radioactive substances into the water and atmosphere. The average equivalent dose constitutes 0.0005 mSv annually. The annual equivalent dose for the personnel is equal to 4.4 mSv. At the same time, the NPPs contribute to a certain degree to the environmental medium improvement, preventing the ingress therein of the sulfur and carbon dioxide, dust and nitrogen oxides by application of fossil fuels. Attention is also paid to reprocessing facilities and also to the nuclear fuel wastes disposal. The advantages of the nuclear power engineering in comparison with the fossil fuel power engineering are enumerated

494

Annual Report 2007. Nuclear Regulatory Authority  

International Nuclear Information System (INIS)

The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.

2004-07-11

495

A new empirical potential function and its application to hydrogen bonding  

International Nuclear Information System (INIS)

A new potential function based on spectroscopic results for diatomic molecules is presented and applied to the hydrogen bonding systems. The potential energy of interaction is supposed to have electrostatic, polarization, dispersion, repulsion and effective charge-transfer contributions. Estimates of the effective charge-transfer quantity have been made based on the average charge of the proton donor and the acceptor atoms. For dimers such as water, methanol, acetic acid and formic acid, the vibrational stretching frequencies and dimerization energies are calculated and discussed in connection with Badger-Bauer rule. (author).

1981-01-01

496

A Nash-Moser theorem for singular evolution equations. Application to the Serre and Green-Naghdi equations  

CERN Document Server

We study the well-posedness of the initial value problem for a wide class of singular evolution equations. We prove a general well-posedness theorem under three assumptions easy to check: the first controls the singular part of the equation, the second the behavior of the nonlinearities, and the third one assumes that an energy estimate can be found for the linearized system. We allow losses of derivatives in this energy estimate and therefore construct a solution by a Nash-Moser iterative scheme. As an application to this general theorem, we prove the well-posedness of the Serre and Green-Naghdi equation and discuss the problem of their validity as asymptotic models for the water-waves equations.

2007-01-01

497

Liuhua 11-1 development -- Design and fabrication considerations for the FPSO Nanhai Sheng Li  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development, design, and fabrication of the crude oil process facilities, and the conversion of an existing tanker for use at the Liuhua 11-1 Field. Over a 16-month period spanning 1994 and 1995, Amoco Orient Petroleum Company, and partners, China Offshore Oil Nanhai East Corporation (CONHE), and Kerr-McGee China Petroleum Ltd., converted a crude oil tanker originally built in 1975 to the Nanhai Sheng Li, the floating production, storage and offloading (FPSO) facility for the Liuhua 11-1 Field. The FPSO will process up to 65,000 BOPD produced from 20 subsea wells located 1.7 miles away. In addition to the processing facilities for produced oil and water, the FPSO has a processed crude oil storage capacity of 715,000 bbls. The ship`s propulsion system was removed during the conversion, because the FPSO is permanently moored at site by means of a 10-point, ``soft`` mooring. The mooring system was ...

1996-12-31

498

Experience with pressuriser for PHT pressure control in TAPP 4 reactor  

International Nuclear Information System (INIS)

In a 540 MWe PHWR reactor at TAPP-4 the pressuriser has been incorporated in the PHT pressure control system to provide the necessary vapour cushion for PHT main circuit to reduce pressure variations due to transients involving swell and shrinkage. Need for the Pressuriser is due to the large inventory in PHT main circuit and relatively large heat source. The incorporation of Pressuriser is one of the modifications while upgrading from prevalent operating 220 MWe reactors to the present 540 MWe at TAPP-4. The sizing, design and selection of the 540 MWe Pressuriser has been done w.r.t swell/shrinkage requirement during normal/transient operation of the reactor. In this paper the commissioning and operating experience of the Pressuriser in conjunction with the PHT pressure control system is presented. During light water commissioning of PHT circuit some major hurdles like failure of pressuriser heaters due to faulty ...

2006-11-13

499

Performance evaluation of low heat rejection engines  

Energy Technology Data Exchange (ETDEWEB)

Improving the performance of the Chinese B135 six-cylinder direct injection turbocharged and turbocompounded Low Heat Rejection Engine (LHRE) was based on experimental and analytical studies. The studies were primarily applied on a B1135 single-cylinder LHR engine and a conventional water-cooled B1135 single-cylinder engine. Performance of the B1135 LHRE was worse than that of the conventional B1135 due to a deterioration in the combustion process of the B1135 LHRE. The combustion process was improved and the fuel injection system was redesigned and applied to the B135 six-cylinder LHRE. The new design improved the performance of the LHRE and better fuel economy was realized by the thermal energy recovered from the exhaust gases by the turbocompounding system.

1994-10-01