Ultra-high pressure water jet: Baseline report
International Nuclear Information System (INIS)
The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of ...
1997-07-01
Railgun. Challenge to ultra-high speed; Railgun. Chokosoku eno chosen
Energy Technology Data Exchange (ETDEWEB)
A railgun has an armature driven between two rail-like conductors. In other words, it is a linear drive device system that drives airframes by using the Lorentz`s force. The system is expected as a next-generation high-speed transport means, or as a means to create such ultimate fields as ultra-high pressures, ultra-high temperatures, and ultra-ferromagnetic fields. This paper is a report on investigations on the relevant technological trends as surveyed by the investigation committee at the Institute of Electrical Engineers of Japan using research reports published inside and outside the country. The reported themes cover explanations from the construction to the pulse power supply that forms the core of the technology, problems in switching, recent status of research and development, and to application fields. Compatibility in the high-level electrical and mechanical performances demanded in the railgun is not as easy as has been anticipated ...
1995-09-12
Effects of modification on microstructure and properties of ultrahigh carbon (1.9wt.% C) steel
British Library Electronic Table of Contents (United Kingdom)
The effects of a modifier that contains Rare Earths (RE), low melting point alloy (Al-Bi-Sb) and Ca-Si alloy on an ultrahigh carbon steel containing 1.9wt.% C were studied. Microstructure characterization was carried out with optical microscopy (OM) and scanning electronic microscopy (SEM) combined with energy-dispersive spectrometry (EDS). Upon modification, the continuous eutectic carbide network structure was broken up and changed to a partly isolated and finer blocky structure in the as-cast alloy. Differential scanning calorimetry (DSC) revealed that the eutectoid temperature increased and the eutectic temperature decreased for the modified alloy. Modification also improved the impact toughness of the tempered steel, with a significant increase from 6.5 to 12.6Jcm^-^2, despite the har...
2011-01-01
Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide
Energy Technology Data Exchange (ETDEWEB)
Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the ...
2010-11-24
Air shifting diffusion; Diffusion d'air par deplacement
Energy Technology Data Exchange (ETDEWEB)
The technique of air diffusion by shifting presents several advantages in terms of thermal comfort, indoor air quality and energy conservation. This book presents the principle, dimensioning, and implementation of air shifting diffusion systems. (J.S.)
2001-07-01
International Nuclear Information System (INIS)
High-power arc lamp design has enabled ultrahigh-temperature (UHT) annealing as an alternative to conventional rapid thermal processing (RTP) for ultrashallow junction formation. The time duration of the UHT annealing technique is significantly reduced from those obtained through conventional RTP. This difference in time may offer the ability to maintain a highly activated ultrashallow junction without being subjected to transient enhanced diffusion (TED), which is typically observed during postimplant thermal processing. In this study, two 200-mm (100) n-type Czochralski-grown Si wafers were preamorphized with either a 48- or a 5-keV Ge"+ implant to 5x10"1"4 cm"2, and subsequently implanted with 3-keV BF_2"+ molecular ions to 6x10"1"4 cm"2. The wafers were sectioned and annealed under various conditions in order to investigate the effects of the UHT annealing technique on the resulting junction characteristics. The main point of the paper is to show that the UHT ...
2005-02-15
A film of GaSb grown epitaxially on a Si substrate is a direct transition semiconductor useful for application as a light source in Si photonics and channel material in next-generation field effect transistors because its energy bandgap is close to the optical fibre communication wavelength and it possesses high carrier mobility. Here, we report a novel method for heteroepitaxial growth of high-quality GaSb/Si films, despite having a lattice mismatch as large as ? 12%, using elastically strain-relaxed GaSb nanodots with ultrahigh density as seed crystals for film growth. The nanodot seed crystals were grown epitaxially by restricted contact with the Si substrate through nanowindows in an ultrathin SiO(2) film on the Si substrate. A light-emitting diode containing GaSb/Si films with a thickness of ? 90 nm fabricated by this method operated at room temperature. The growth method was also used to fabricate AlGaSb films of high quality. Our method ...
2011-05-17
The electric fuel zinc-air battery option
Energy Technology Data Exchange (ETDEWEB)
With specific energy of more than 200 Wh/kg, the Electric Fuel zinc-air battery delivers as much as eight times the energy of lead-acid traction battery, more than twice the energy of the nearest advanced-battery competitor, and as much energy as a tank of gasoline. (author)
1995-12-31
High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy
UK PubMed Central (United Kingdom)
PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The zinc-air battery/fuel cell is an old technology invented one hundred years ago. However, there is renewed interest in this technology in response to the growing need for clean energy technology. The zinc-air battery/fuel cell is more attractive than similar technologies because its characteristics include high power density, safe operation and storage, and low cost. Zinc-air battery/fuel cells can be made in milliwatts to mega watts to accommodate different applications. The zinc-air battery/fuel cell has four major designs, namely primary, mechanically rechargeable, continuous feed and electrically rechargeable zinc-air battery/fuel cells. Among the different designs, the most common is the air cathode. There are 3 generations of catalysts used in the air cathodes. This paper discussed the different designs of the ...
2010-07-01
Gamma-ray burst (GRB) is one of the candidates of high-energy cosmic-ray acceleration sites. They may be also ultra-high-energy (above 3 EeV) cosmic-ray (UHECR) sources. In this paper, we discuss possibilities and implications of high-energy cosmic-ray acceleration in GRBs. (1) First, we show that not only protons but also heavier nuclei can be accelerated up to ultra-high energies in both usual high-luminosity (HL) and low-luminosity (LL) GRBs by using the Geant4. LL GRBs may also make a significant contribution to the observed UHECR flux if they form a distinct population, and we investigate cosmic-ray acceleration in LL GRBs in detail. (2) Second, we discuss implications of the GRB-UHECR hypothesis (and Hypernova-UHECR hypothesis) to cosmic-ray astronomy. HL GRBs and LL GRBs will lead to different source number densities as UHECR sources, so that the determination of the number ...
2008-01-01
Use of fuel cells to meet military requirements for mobile power
International Nuclear Information System (INIS)
'Full text:' The use of fuel cell technology in military applications will depend on safe, high energy density systems being developed. An important part of using this technology is also the development of alternative hydrogen producing fuels with high energy densities and are easy to transport. Fuel cells are now a very large R and D effort for several military applications around the world. The major reason is because of the high power demands needed requires electrical energy sources that far exceed the capabilities of batteries currently being fielded for portable applications. Fuel cells are regarded as highly efficient, tactical energy converters that can be adapted for wide range of power requirements. They are potentially the lowest weight power source when coupled with batteries or capacitors to form hybrid systems. Generally electrical power is needed to support a number of applications from ...
2004-09-25
Energy Technology Data Exchange (ETDEWEB)
This guidebook concerns the design of air-conditioning and air-treatment installations in recent and old buildings. The design of indoor atmosphere treatment systems is based on a rigorous and safe methodology. The following aspects are reviewed: situation of ambient air treatment, different aspects of a project, humid-air technique, principles of air treatment, basic conditions for a successful project, determination of enthalpy and hydric loads of rooms, design of ambient treatment systems, cold water production using a thermodynamical system, aeraulics, hydraulics, acoustics, logics of operation, forecasting of energy consumptions, global management of air-conditioning installations, ambient air-treatment systems. (J.S.)
1999-07-01
Evaluation of carbon substrates for bifunctional air electrodes applied in zinc-air-batteries
Energy Technology Data Exchange (ETDEWEB)
The key component for improving the energy efficiency and cycle life of the electrically rechargeable zinc-air battery is the bifunctional air electrode. The air electrodes described in this paper contained different types of carbon black as the substrate for the perovskite catalyst (La{sub 0.6}Ca{sub 0.4}CoO{sub 3}). Morphological and physical properties of the carbon substrates play an important role in enhancing the activity and stability of the bifunctional air electrode. Current-potential curves and cycle-life tests were applied in order to gather information on the activity and stability of these electrodes. (authors)
2000-07-01
Energy-conscious air-side design: Phase 1 of energy use minimization
Of the many energy-conservation options available to the design engineer, a system-management approach is recommended as one that will effect maximum benefits to the owner. Systems management includes energy-conscious consideration of design criteria, design details, installation, testing and balancing, and operation. It requires the informed participation of the design engineer, contractor, testing and balancing (TAB) engineer, and owner/operator. Within limits, almost every component of HVAC systems offers an opportunity to conserve energy. Many of these impact energy determinants such as system static pressure, system total air flow, or the quantity of outside air. A few design considerations for energy conservation in a simple system and the impact that the TAB work has on these are illustrated. Particular attention is devoted to the ...
1981-01-01
Edge biasing in the WEGA stellarator
Energy Technology Data Exchange (ETDEWEB)
The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The focus of this work is ...
2009-02-27
Energy Technology Data Exchange (ETDEWEB)
Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)
2006-07-01
Current ventilation and air conditioning systems and strategies
Energy Technology Data Exchange (ETDEWEB)
The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor air quality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)
1994-02-01
First plasma experiment on spherical tokamak device UTST
International Nuclear Information System (INIS)
The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasma obtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma obtained 10 kA by using only outer PF coils and single ST was generated at the lower area (z=-0.3 - -1.0[m]) close to a washer gun. This result ...
2009-04-01
Epitaxial stabilization of MnO(111) overlayers on a Pd(100) surface
International Nuclear Information System (INIS)
The growth of epitaxial MnO(100) and MnO(111) layers on Pd(100) surface has been investigated by spot-profile analysis low-energy electron diffraction, dynamic atomic force microscopy, photoemission and high-resolution electron energy loss spectroscopy, and density functional theory. We have found that despite the large lattice mismatch to the Pd(100) substrate, the MnO(100) layers are kinetically stabilized at low temperatures (?350 deg. C) and at oxygen pressures between 2x10-7 and 5x10-7 mbar. Annealing in ultrahigh vacuum at 650 deg. C or, alternatively, deposition of manganese metal in oxygen pressure -7 mbar causes the transformation of the MnO(100) to a polar MnO(111) surface, which is decorated by triangular pyramids with (100) side facets. It is suggested that the growth of MnO(111) layers is energetically preferred over MnO(100) due to the epitaxial stabilization at the metal-oxide interface.
2007-06-01
Energy-filtered electron microscopy for imaging core-shell nanostructures
Energy Technology Data Exchange (ETDEWEB)
CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the core-shell arrangements in ...
2008-08-15
The solar energy in Lebanon: an inexhaustible and economical energy
International Nuclear Information System (INIS)
The article describes the energy in Lebanon. In 1995, 97% of the imported energy was based on hydrocarbons. Fuel and gas oil present 66% of the final energy. Air pollution is mainly caused by the transportation sector (vehicles and buses...) which presents 70% of the global atmospheric pollution. Renewable energy such as biomass, fossil energy, hydro-energy, solar energy... are also described. The solar energy was defined as a best solution that preserve health in Lebanon. The different applications of the solar for energy production is discussed: photovoltaic , thermal heating, sanitary hot water, electrical heaters, solar water heaters...In conclusion, solar heaters economize 80% of the annual energy expenses
1997-06-01
Air pollution abatement measures
Energy Technology Data Exchange (ETDEWEB)
The major inquiry of the political party 'Die Gruenen' touches all problems connected with air pollution. The Federal Government states that an extensive air pollution abatement program, i.e. the revision of existing regulations and implementation of new ones has been allowing the realization of all essential environmental aims originally headed for three years ago in the field of air pollution abatement. Achievements such as these will bring about another obvious improvement of the air quality of the Federal Republic of Germany in the coming years. The recent development of energy economy has also proved to be having an obivously positive effect on the environment and pollution abatement. (HSCH).
1987-01-14
Energy Technology Data Exchange (ETDEWEB)
This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.
2001-07-01
Mathematical modeling of a direct contact humidification?dehumidification desalination process
British Library Electronic Table of Contents (United Kingdom)
Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...
2009-01-01
Texas - Energy Collaborations Working for the Environment
Energy Technology Data Exchange (ETDEWEB)
This fact sheet highlights how renewable energy and energy efficiency technologies can and are being used to reduce air emissions and meet environmental goals, showcasing case studies and technology-specific topics.
2007-12-01
The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
The report deals with the energy consumption of traffic and its emissions of hazardous substances into the air, and stresses the advantages of the electric car with respect to energy consumption and noise generation. 5 figs., 3 refs.
1991-01-01
Indoor climate seminar; Sisaeilmastoseminaari
Energy Technology Data Exchange (ETDEWEB)
The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.
1989-12-31
Ultra high-speed (508 MHz) beam position digital feedback system
Energy Technology Data Exchange (ETDEWEB)
The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters ...
1997-02-01
Potassium deposition on a thiophene-terminated alkanethiol monolayer
International Nuclear Information System (INIS)
Potassium deposition in ultrahigh vacuum on 12-(3-thienyl)dodecanethiol monolayers assembled on gold surfaces has been investigated using X-ray and ultraviolet photoelectron spectroscopies (XPS and UPS). Angle-resolved XPS indicates that initially deposited potassium penetrates the self-assembled monolayer (SAM) and diffuses to the SAM/Au interface. Even after large metal doses, the presence of thiophene ring valence electronic states in the UPS spectra confirms that most of the thiophene rings (at the SAM/vacuum interface) are not covered by potassium. The binding energy shifts of the thiophene ring valence states and the C1s and thiophene S2p peaks, referenced to the Fermi level, are due to the work function changes of the gold substrate. This indicates that these electronic states are pinned to the vacuum level, in contrast to the thiolate S2p orbital, which is pinned to the Fermi level. For large potassium doses, the appearance of new ...
2009-05-01
Kapitza conductance of the (100) surface of copper
International Nuclear Information System (INIS)
Measurements of the Kapitza conductance to liquid helium II across the (100) surface of single crystals of copper are presented. The temperature range of these measurements was 1.6-- 2.1 K. The sample surfaces were subjected to several different treatments. Some surfaces were cleaned by low-energy argon ion bombardment, annealed in an ultrahigh-vacuum system, and preserved under vacuum until purified liquid helium was admitted. Other surfaces were intentionally damaged by machining and/or exposure to the atmosphere. The conductance after these latter treatments was found to be about a factor of three higher than that of the more ideally cleaned and annealed surfaces, and a significant difference in the temperature dependence of the conductance was also observed. Conductances were reproducible for similarly treated surfaces and correlated with surface damage determined by x-ray diffraction. The relationship of these results to the numerous ...
Energy Technology Data Exchange (ETDEWEB)
Prior to an industrial-scale test of zinc/air batteries at Greven, the TUeV Bayern-Sachsen carried out preliminary tests on behalf of the Deutsche Bundespost. The results were quite promising: The energy density of the new battery is ten times as high as that of conventional lead batteries, and the battery-powered test vehicle had a range of up to 300 km. (orig.)
1994-01-01
Snow Survey & Water Supply | NRCS
Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...
2011-08-21
Capturing energy in the air to power electronics | SmartPlanet
...smart grid applications where you could place them very close to the high-voltage transmission lines , very close to transformers and so on. Photo:...
Briefing on the Latest Sanctions on Iran
of refined petroleum and energy traders have stopped sales of refined product to Iran. Jet fuel suppliers are now refusing to supply jet fuel to Iran Air at most destinations in...
2011-08-28
Liquid hydrogen droplet as an ultrahigh-Q optical cavity
Energy Technology Data Exchange (ETDEWEB)
We describe a liquid hydrogen droplet as an optical cavity via whispering gallery modes. We show that the droplet leads to an ultrahigh-cavity-Q value of 2.5x10{sup 9} in visible region. We show also that the high-Q droplet results in a huge Raman nonlinearity, generating a stimulated Raman comb series covering whole visible region.
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Energy conservative building design has triggered greater interests in developing flexible and sophisticated air conditioning systems capable of achieving enhanced energy-savings potential without sacrificing the desired thermal comfort and indoor air quality (IAQ). This research work greatly aimed at achieving enhanced energy conservation, good thermal comfort and better IAQ for space conditioning with the application of combined variable refrigerant volume (VRV) and variable air volume (VAV) air conditioning (A/C) systems. Experimental investigation on the proposed combined air conditioning system with the application of intelligent fuzzy logic controller was performed for summer and winter climatic conditions to substantiate the energy-savings capability. The proposed system experimentally ...
2010-04-15
Symposium on wood fuel and air purification. Symposium Brennstoff Holz und Luftreinhaltung
Energy Technology Data Exchange (ETDEWEB)
Lectures were held on forest and wood management, the forest as an energy source and the emission problem of wood combustion, future emission limitating regulations for wood firing, influence of firing technique on air pollution abatement and constructive and operational air pollution abatement measures with manually and continuously fuelled furnaces.
1981-01-01
International Nuclear Information System (INIS)
Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear ...
1993-08-15
Technology base research on the slurry-zinc/air battery system: Final report
Energy Technology Data Exchange (ETDEWEB)
The slurry-Zn/air battery system has received renewed R and D interest because it does not have the shape-change problems of batteries with Zn-plate electrodes and can sustain higher current densities and specific peak power than other metal-air battery systems. Additional advantages of the slurry-Zn/air battery include safety, low environmental impact, potential low cost, and separation of energy density from power density functions for design purposes. In this work we present results obtained at the individual cell level as a basis to estimate the performance of a secondary slurry-Zn/air battery system. The expected specific energy of such systems has been increased as a result of the use of capacity-extension additives, which has been one of the major thrusts of this work. 8 refs., 20 figs., 5 tabs.
1988-08-01
Energy saving self-powered industrial dehumidifier
Energy Technology Data Exchange (ETDEWEB)
An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.
1988-07-26
General flow and thermal boundary conditions in indoor air flow simulation
Energy Technology Data Exchange (ETDEWEB)
The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, air quality, and thermal comfort in a real building. (author)
1994-12-31
Employing exergy-optimized pin fins in the design of an absorber in a solar air heater
Energy Technology Data Exchange (ETDEWEB)
Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)
2010-02-15
Energy Technology Data Exchange (ETDEWEB)
Unlike the conventional automotive, modem railway trains are designed with non-openable windows; and a mechanical ventilation and air-conditioning (MVAC) system is installed in each train compartment for better indoor air quality as well as to provide a thermally comfortable environment. The ventilation rate is no doubt a critical element in the design of a MVAC system, especially in Hong Kong where the daily passenger load is extremely heavy. Earlier studies illustrated that carbon dioxide can be controlled at 1000 ppm by increasing the ventilation rate to 25.2 m{sup 3} h{sup -1}; however, it will also lead to an increase in energy consumption. In this paper, the electrical energy consumption at various ventilation rates was studied, and the cost of maintaining a low carbon dioxide level was estimated These provide solid information for the local railway companies to improve the ...
2000-01-01
Thermal energy considerations on solar cavity wall building
Energy Technology Data Exchange (ETDEWEB)
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
1983-02-01
Multicriteria analysis of ventilation in summer period
Energy Technology Data Exchange (ETDEWEB)
This paper presents a multicriteria analysis of ventilation during summertime in Europe. Multicriteria analysis theories are used to determine the most suitable ventilation strategy on a university building, that is to say to ensure the best possible indoor air quality, thermal comfort of the occupants and the lower energy consumption in case of accelerated diurnal or nocturnal ventilation and/or air conditioning. After defining the possible actions, the criteria of quality regarding thermal comfort, indoor air quality and energy consumption are defined. The possible actions are then assessed relative to each of these three criteria and ranked from the best to the worst ones using two different multicriteria analysis methods. (author)
2002-02-01
Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet
Energy Technology Data Exchange (ETDEWEB)
Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.
1995-11-01
Super-ventilation in commercial buildings; Surventilation des locaux tertiaires
Energy Technology Data Exchange (ETDEWEB)
The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and air quality
1995-09-01
Energy conservation by partial recirculation of peanut drying air
Energy Technology Data Exchange (ETDEWEB)
Conventional, recirculating, and intermittent type peanut dryers were compared in a three-year study. Comparisons indicate that partial recirculation of peanut drying air may reduce energy consumption per unit of water removed by approximately 25% while also reducing required drying time and maintaining high quality.
1983-06-01
Introduction of energy saving type air conditioner
Energy Technology Data Exchange (ETDEWEB)
It is reported that due to the large demand for electricity in Japanese homes and given the fact that the energy consumption rate of air conditioners to the total energy consumption rate in an average home exceeds 20%, an energy saving-type room air conditioner is essential, also for environmental reasons. Japanese customers ranked high running costs as a major drawback of conventional equipment. Toshiba started developing the first generation energy saving air conditioners in 1993. Improvements to the concept were made and the 1995 model offers a heating COP of 4.65 and a cooling COP of 4.3 at rated conditions, an improvement of more than 30% compared to the conventional model. Various component improvements have led to this high performance including the indoor fan design, a DC compressor motor and inverter using digital sampling, advanced ...
1996-07-01
SERAPHIM: A propulsion technology for fast trains
Energy Technology Data Exchange (ETDEWEB)
The Segmented Rail Phased Induction Motor (SERAPHIM) is a compact, pulsed linear induction motor (LIM) offering a unique capability for very high speed train propulsion. It uses technology developed for the Sandia coilgun, an electromagnetic launcher designed to accelerate projectiles to several kilometers per second. Both aluminum cylinders and plates were accelerated to a kilometer per second (Mach 3) by passing through a sequence of coils which were energized at the appropriate time. Although this technology was developed for ultra-high velocity, it can be readily adapted to train propulsion for which, at sea level, the power required to overcome air resistance limits the operational speed to a more modest 300 mph. Here, the geometry is reversed. The coils are on the vehicle and the ``projectiles`` are fixed along the roadbed. SERAPHIM operates not by embedding flux in a conductor, but by excluding it. In this propulsion scheme, pairs of ...
1995-06-01
International Nuclear Information System (INIS)
The section on environmental impacts covers global environmental concerns and air pollution. Energy systems includes the following: alternative fuels; co-generation; fossil fuels; mechanical thermal storage; fission/fusion; thermal management; electric and hybrid vehicles. The section on renewable energy sources includes biomass, hydrogen, and solar. This volume also contains separate sections for stirling cycles, policy issues, and new technologies for energy utilization. Separate abstracts were prepared for 150 papers of this volume.
1993-08-08
Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur
Energy Technology Data Exchange (ETDEWEB)
This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)
2000-07-01
British Library Electronic Table of Contents (United Kingdom)
In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...
2009-01-01
Search for tachyons preceding cosmic ray extensive air showers of energy >= 10"1"4 eV
International Nuclear Information System (INIS)
A search for tachyons preceding extensive air showers has been conducted using an air shower array operated in conjunction with a large aperture, five element cosmic ray telescope. More than 200 000 air showers of primary energy >10"1"4 eV were observed over a period of 223 days and a 290 #mu#s period before each of these showers was scanned for a related particle signal from the telescope. In this way a particle arrival time spectrum containing 1519 tachyon candidates was observed. No convincing evidence was found for any subgroup of these events that might be attributable to tachyons. (author).
Coordination of air pollution abatement. Ilmansuojeluohjelmien yhteensovittaminen
Energy Technology Data Exchange (ETDEWEB)
Finland has set up several national air pollution control programmes in order to implement international conventions. As a rule these programmes have focused on one pollutant. The national second carbon dioxide commission is at present working on a new programme to curb carbon dioxide emissions, and this will unavoidably affect other programmes, too. This study presents the existing programmes and their respective implementation costs. The aim has been to focus on the interaction between different air pollution combatting measures and the possibilities of setting priorities on a cost basis. The main result is that it will be difficult to integrate overall aims for general welfare and subsequent energy consumption with environmental considerations, especially in air pollution control. If the increase in energy generation follows current scenarios, the costs for ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This document deals with energy management in buildings. It presents the conditions for a good implementation of energy management. These conditions include the total involvement of the management and the training of the staff. The structure of this implementation is presented together with the tools for an efficient energy management. Eventually, information on air quality and comfort in buildings is provided, as well as the management of complaints linked to them. (TEC). 1 tab.
1993-12-31
Air pollutant emissions due to energy utilization in Turkey
International Nuclear Information System (INIS)
Pollutant emissions due to fossil fuel and biomass energy utilization in Turkey have been estimated. Standard emission factors were used for estimating the levels of particulate matter, sulfur oxides, nitrogen oxides, carbon monoxide, volatile organic compounds, and aldehydes. The results are presented for different fuels and energy-consuming sectors for the reference year 1987. Total Turkish emissions vs energy consumption are presented for every fifth year since. 1960. (author).
Energy Technology Data Exchange (ETDEWEB)
A simple theory for predicting the convective energy loss from side-facing cavity receivers in windless environments has been developed. The approach used is to determine the velocity distribution of the incoming air in the aperture plane (and thereby the rate of mass entrainment); and then to estimate the bulk temperature of the heated emerging air. The convective loss is then calculated from an energy balance. To illustrate this theory, numerical results applicable to the 2.15 meter cubic cavity being tested in the laboratory are provided.
1981-01-01
A conceptual model for laboratory ventilation greenhouse gas planning
British Library Electronic Table of Contents (United Kingdom)
There is increasing pressure to operate laboratory facilities in environmentally and financially sustainable ways. A key factor in achieving this goal is careful consideration of how energy is used by the buildings' ventilation system, both for conditioning air supplied to the laboratories and the energy used moving air through the building. Traditionally, laboratory energy use is treated as an engineering concern within the scope of the building's overall design and operation. However, this approach limits the involvement of key stakeholders in many important decisions and can lead to unexpected safety concerns for the laboratory's users. We believe that a broad view of the parties affected by a laboratory building's operations is necessary to avoid having the various stakeholders working...
2011-01-01
Realization of good indoor climate in low-energy office
Energy Technology Data Exchange (ETDEWEB)
Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting ...
1994-12-31
Theory of multifoil collision supercompression
Energy Technology Data Exchange (ETDEWEB)
Investigations of superdense compression touch on such problems as ultrahigh-frequency oscillations of matter in the generation of gravitational waves, the powerful pumping of hard coherent radiation, and the laboratory simulation of stellar interiors. This paper reviews the theory of supercompression and discusses some experiments involving multifoil collision supercompression.
1980-01-01
Incidence and Diversity of Potentially Highly Heat-Resistant Spores Isolated at Dairy Farms
UK PubMed Central (United Kingdom)
The presence of highly heat-resistant spores of Bacillus sporothermodurans in ultrahigh-temperature or sterilized consumer milk has emerged as an important item in the dairy industry....Full Text Available
2005-03-01
Centrifugal potential energy : an astounding renewable energy concept
Energy Technology Data Exchange (ETDEWEB)
A new energy concept known as centrifugal potential energy was discussed. This new energy concept is capable of increasing the pressure, temperature and enthalpy of a fluid, without having to apply work or heat transfer to the fluid. It occurs through a change in the centrifugal potential energy of the flowing fluid in a rotating frame of reference or a centrifugal force field, where work is performed internally by the centrifugal weight of the fluid. This energy concept has resulted in new energy equations, such as the Rotational Frame Bernoulli's Equation for liquids and the Rotational Frame Steady-Flow Energy Equation for gases. Applications of these equations have been incorporated into the design of centrifugal field pumps and compressors. Rather than compressing a fluid with a physical load transfer, these devices can compress ...
2010-07-01
Designing a healthy house - an overview
Energy Technology Data Exchange (ETDEWEB)
There are certain factors to take into account when determining the suitability of a healthy house site. Power lines, agricultural spraying, vehicle exhaust, and industrial pollution are all potential sources of indoor air contamination. It is recommended that a environmental assessment be done to determine whether there are specific sources of contamination. Good drainage is required. The surrounding landscaping should be open and sunlit, and with low maintenance requirements. Decks and fences made from pressure-treated or chemical treated lumber should be avoided. One of the early decisions in the design process is the choice of the structural system. The key with all foundation types is to control moisture, whether from rain, from the ground, or the condensation of moisture from the air with cooling. The construction frame is sealed away from the occupants by the air/vapor barrier, so only in extreme cases is it ...
1999-11-01
International Nuclear Information System (INIS)
The mixed structure of a nuclear reactor building is composed of SC-columns, S-beams, S-joints and PCa-panels. Following the last report (Part 7)[1], the main test results of the mixed structure, that is, the deformation mode, strain distribution and shear strength, are described. The S-joints using ultrahigh strength materials had no buckling nor shear slipping. The proposed mixed structure resisted the external horizontal forces under integrated uniformity among SC-columns, S-joints and PCa-panels. It could be confirmed that the mixed structure can be established. (author)
1993-08-15
International Nuclear Information System (INIS)
The objective of this study is to comprehend the basic structural characteristics of box shaped mixed structures proposed for a future nuclear reactor building structure. Specimens of reinforced concrete precast panel walls of the mixed structures were prepared using ultrahigh strength materials. Two bending shear tests were conducted with a parameter of the quantity of reinforcement bars. The results include: (1) Relationship of shear stress and the angle of the structure, and (2) Failure mode. (author)
1993-08-15
Heat pumps in urban space heating systems: Energy and environmental aspects
International Nuclear Information System (INIS)
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with heat pump systems to obtain ...
1991-01-01
Coal: being aware of new power solutions in coastal regions
Energy Technology Data Exchange (ETDEWEB)
Cheap air conditioning from oceanic temperature differences is a possible new competitor for coal in coastal regions. Coal suppliers planning expansion in growing economies need to be aware of the possibilities and limitations of this new competitor. Ocean thermal energy conversion (OTEC) used to be uneconomic but the National Energy Laboratory of Hawaii (NELH) has developed a very economic method of utilising the temperature difference between warm ocean surface and cold deep ocean to generate energy for air conditioning. The article outlines the process and mentions demonstrations of OTEC technology to produce electricity and air conditioning at a site in Kailua-Kona, Hawaii. Indonesia and India have viable sites for OTEC installations, and NELH is working with Madras State on a project to construct a commercial OTEC plant in India. 2 photos.
1998-08-01
Energy Technology Data Exchange (ETDEWEB)
We present two applications of CR-39 to estimate biological effects of heavy ion irradiation. The accurate measurement of fluence of ions using CR-39 is indispensable to calculate the action cross sections for biological effects. Ions with 6 MeV/n at the Medium Energy Beam Course, HIMAC (NIRS) were extracted to the air, and degraded with the air. DNA and living cells were irradiated by ions with various specific energies at several air columns along with the Bragg curve. DNA strand breaks and cell killing were measured and the results were converted to the action cross sections using the fluence measured with CR-39 at the irradiation positions. Another example of the application of CR-39 is to identify whether the ions with a specific energy pass through the cell or stop within the cell. (author)
2001-10-01
International Nuclear Information System (INIS)
We studied the epitaxial growth of iron silicide (#epsilon#-FeSi,#beta#-FeSi_2, and #alpha#-FeSi_2) nanodots on Si (111) substrates by Fe deposition on Si nanodots on Si (111) substrates with ultrathin Si oxide films using reflection high-energy electron diffraction, scanning tunneling microscopy, and transmission electron microscope (TEM). We formed almost single phase iron silicide nanodots by controlling the Fe deposition conditions; growth temperature, deposition rate, and amount. The #epsilon#-FeSi or #alpha#-FeSi_2 nanodots were epitaxially grown in a dome shape with an average size of #approx#5 nm and an ultrahigh density (>10"1"2 cm"-"2) on the surface. We formed #approx#2-nm high and #approx#8-nm wide #beta#-FeSi_2 nanodots in a dome shape with a density of #approx#5x10"1"1 cm"-"2 on the surface. Cross-sectional TEM images revealed that the #beta#-FeSi_2 growth continued beneath the Si surface. The part of the #beta#-FeSi_2 nanodot ...
2005-08-15
Transverse glow discharges in supersonic air and methane flows
British Library Electronic Table of Contents (United Kingdom)
Transverse glow discharges in supersonic air and methane flows are studied both experimentally and theoretically. The experiments show that a diffuse volume discharge filling the whole cross section of the flow can easily be initiated in air, whereas a diffuse discharge in a methane flow shows a tendency to transition into a constricted mode. The electron transport coefficients (mobility and drift velocity) and the kinetic coefficients (such as collisional excitation rates of the vibrational levels of a methane molecule, as well as dissociation and ionization rates) are calculated by numerically solving the Boltzmann equation for the electron energy distribution function. The calculated coefficients are used to estimate the parameters of the plasma and the electric field in the positive co...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather ...
2006-09-15
Transportation 2005. [Denmark]. Trafik 2005; Problemstillinger, maal og strategier
Energy Technology Data Exchange (ETDEWEB)
The Danish Ministry of Transportation has prepared a national plan of transportation, for the years until 2005. Official policy concerning land, maritime and air transport, personal and cargo transportation, investments and expenditures is outlined. Environmental impacts of energy consumption and air pollution abatement measures are considered. (EG)
1993-01-01
Thermodynamic calculations for Otto cycle engines using methanol as a fuel
Energy Technology Data Exchange (ETDEWEB)
Equations are derived to calculate the work required for the isentropic compression of a 2-phase fuel-air mixture. Methanol evaporation during compression substantially reduces compression work and improves cycle efficiency and maximum power. Effects of evaporative cooling in the intake manifold are calculated. Energy d. of methanol and gasoline fuel-air charges are compared. The phase equilibrium and evaporation rate are causes of the poor cold-starting performance of methanol.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
The author cites the example of Gelsenkirchen in order to illustrate the measures taken in the field of power supply with regard to air pollution abatement. (orig.) [Deutsch] Der Verfasser gibt am Beispiel der Stadt Gelsenkirchen einen Ueberblick darueber, was hinsichtlich des Klimaschutzes - und zwar bezogen auf die Energieversorgung - in den letzten Jahren in Gelsenkirchen getan wurde. (orig.)
1996-07-01
A search for tachyons in extensive air showers
International Nuclear Information System (INIS)
A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).
UK PubMed Central (United Kingdom)
Biomass fuel burning leads to high levels of suspended particulate matter and hazardous chemicals in the indoor environment in countries where it is in common use, contributing significantly to indoor...Full Text Available
2010-07-01
International Nuclear Information System (INIS)
The electromagnetic field due to an air explosion is here studied: neutron and the gamma-rays, generated by neutronic reactions, deposit energy which ionizes atmosphere; recoil electrons are also created by gamma collisions. This data set allows to solve the Maxwell equations which manage the electromagnetic field. The TRIPOLI-2 code studies the coupled neutron-gamma transport in 3D- geometries by the Monte Carlo method. The code has been modified to calculate the photon energy deposited in matter and the recoil electron current created by Compton effect. The method is tested wiht a simple case; then neutron and gamma transport is studied in air kerma, deposited photon energy, electron current are calculated as functions of space and time and the contributions of the different neutronic reactions are separately evaluated. The calculations presented here are only part of studies ...
1988-09-12
NASA Aeronautical Engineenng Aera 3ring Aeronautical Engineenng
for an Air Force Manufacturing technology program whose aim is the establishment of organic matrix ...... display considerations for advanced energy/flight management sys- ...... Future System - The Roadmap of the System of the Future - ...... data storage units, pilot's guidance indicators, and a quick look ...
Cupola Furnace: Machine-Readable Bibliographic Data Base.
One of the tasks comprising ERDA Contract EY-76-S-02-2840, ''Minimization of Cupola Energy and Air Pollution,'' has been the carrying out of a comprehensive survey of world literature relating to the cupola furnace for melting of cast iron. It was decided...
1978-01-01
Section 204 of the Energy Independence and Security Act of 2007 (EISA 2007) requires EPA to assess and report to Congress on the impacts to date and likely future impacts of the increased use of biofuels as required by the Clean Air Act, section 211(0). Environmental issues (...
Energy Technology Data Exchange (ETDEWEB)
'Within 15 years the energy consumption bottleneck has shifted from the supply side to emissions, i.e. to the waste side.' Reflecting this statement one may realize the importance of lending more weight to energy conservation but may also be induced to critically analyze the corresponding measures. First results of such reflections are given with regard to the payback periods of air pollution abatement measures relative to the additional emissions they cause. (orig.).
1991-12-18
New developments in the Electric Fuel Ltd. zinc/air system
Energy Technology Data Exchange (ETDEWEB)
Electric Fuel Ltd. is engaged in the design, development and commercialization of its proprietary zinc/air battery technology for electric vehicles, consumer electronic products and defence applications. To meet the challenging requirements for propelling an all-electric bus, the Vehicle Division sought a unique solution: an all electric battery-battery hybrid propulsion system. The high energy zinc/air battery is coupled with a high-power auxiliary battery. The combined system offers zero emission, high power and long range in an economically viable package. The consumer battery group has developed a high power primary zinc/air cell aimed at cellular phone users, offering extended use, convenience and low cost. (orig.)
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
1993-07-01
Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur
Energy Technology Data Exchange (ETDEWEB)
This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)
1997-07-01
The Polish Nuclear Society on the energy situation in Poland
Energy Technology Data Exchange (ETDEWEB)
Discusses the resolution of the 2. Congress of the Polish Nuclear Society on the energy situation in Poland and recommendations for energy policy. Recommendations for use of nuclear power plants in Poland are made considering environmental pollution from coal combustion (air pollution by sulfur dioxide, nitrogen oxides and carbon dioxide as well as water pollution by salt from mine water discharged to rivers), development of the Polish economy, forecast increase in energy consumption and the role of nuclear energy in other European countries. Research on nuclear power plants, safety and environmental aspects as well as comparative efficiency of coal-fired power plants and nuclear power plants is evaluated.
1993-10-01
Most K-12 schools could save 25% of their energy costs by being smart about energy. Nationwide, the savings potential is $6 billion. While improving energy use in buildings and busses, schools are likely to create better places for teaching and learning, with better lighting, temperature control, acoustics, and air quality. This brochure, targeted to school facilities managers and business officials, describes how schools can become more energy efficient.
2001-08-06
Energy Technology Data Exchange (ETDEWEB)
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
2007-05-01
Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions
Energy Technology Data Exchange (ETDEWEB)
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
2007-02-01
Ventilation concept, indoor air quality and measurement results in the ``Passivhaus Kranichstein``
Energy Technology Data Exchange (ETDEWEB)
The ``Passivhaus Darmstadt-Kranichstein`` is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m{sup 2} of living area, thereof about 12 kWh are needed for room heating. The determining factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The results of a detailed monitoring program allow decisive statements concerning reduction of energy consumption, relief of environment, indoor air quality, and thermal comfort. (author)
1994-12-31
Prohibitions against the combustion of solid and liquid fuels in urban areas
Energy Technology Data Exchange (ETDEWEB)
Much as it is accepted for pollution control reasons air pollution abatement still is the subject of heated debates. Pollutant emissions can considerably be reduced with the help of electric power supplies. In order not to prejudice electric power users tariffs have to be adapted to the prices of other energy sources available on the market. There is a general need for energy conservation, resource conservation and the reduction of carbon dioxide emissions. Thermal insulation is among the remedial measures. Fundamental air pollution abatement measures will have to be avoiding smog warnings which are known to considerably interfere with both economic and private activities.
1988-02-01
International Nuclear Information System (INIS)
A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)
2010-12-01
Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
2011-09-01
Energy Technology Data Exchange (ETDEWEB)
An analysis is given of the problems which can be solved by the use of electric-powered vehicles. A detailed comparison is made of the energy consumption and the air polluting emissions of electric and conventional vehicles, taking into account the energy consumption of the vehicles and the primary energy consumption of electric power generation and automotive fuels production. Also the air pollution, as a result of power generation and fuel production are considered. In chapter 1 an outline is given of the traffic and transportation sector in the Netherlands with special attention to data on the energy consumption and the air pollution of this sector. Based on these data the problems can be formulated for which the application of electric vehicles can be a solution. In chapter three a brief description is given of the technical ...
1992-09-01
New materials for future generations of III-V solar cells
Energy Technology Data Exchange (ETDEWEB)
Three- and four-junction III-V devices are proposed for ultrahigh-efficiency solar cells using a new 1-eV material lattice-matched to GaAs, namely, GaInNAs. We demonstrate working prototypes of a GaInNAs-based solar cell lattice-matched to GaAs with photoresponse down to 1 eV. Under the AM1.5 direct spectrum with all the light higher in energy than the GaAs band gap filtered out, the prototypes grown with base doping of about 10{sup 17}&hthinsp;cm{sup {minus}3} have open-circuit voltages ranging from 0.35 to 0.44 V, short-circuit current densities of 1.8 mA/cm{sup 2}, and fill factors from 61{percent} to 66{percent}. To improve on the current record-efficiency tandem GaInP/GaAs solar cell by adding a GaInNAs junction, the short-circuit current density of this 1-eV cell must be significantly increased. Because these low short-circuit current densities are due to short diffusion lengths, we have demonstrated a depletion-width-enhanced ...
1999-03-01
Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen
International Nuclear Information System (INIS)
Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the ...
2004-07-19
Energy Technology Data Exchange (ETDEWEB)
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation, ...
1990-01-01
Externally fired combined cycle demonstration
Energy Technology Data Exchange (ETDEWEB)
Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy ...
1995-11-01
Metrologic analysis of energy and economic growth rate and study of the countermeasures in China
International Nuclear Information System (INIS)
Coal output in China increased from 872mt in 1985 to 1080mt in 1990, representing an annual growth rate of 4.37% . As the biggest coal burning country, it gives out a large amount of CO_2 and other pollutants into air, resulting in serious air pollution and sharing a great part in creating the global greenhouse effect. On the other hand, China faces severe energy shortage. Coal will remain the most important energy resource for a long time, Using the method of econometrics, this paper analyses the relations between China's energy production, consumption increase and national economic growth in the list forty years, makes comparisons with other countries, and points out problems of China's energy consumption increase and economic development. On this basis the strategy for developing China's energy industry is put forward, In the end, the ...
1992-10-13
Electrically rechargeable zinc/air battery: a high specific energy system
Energy Technology Data Exchange (ETDEWEB)
This contribution describes our research and development efforts towards the demonstration of a light-weight, low-cost 12 V/20 Ah electrically rechargeable Zn/air battery. We successfully developed electrodes having active areas of up to 200 cm{sup 2}. Deep discharge cycles at different currents as well as current-voltage curves are reported for a 10 cell Zn/air battery (serial connection) with a rated capacity of 20 Ah. Based on the discharge cycle at a power of 19 W, and the weight of the battery, a specific energy of more than 90 Wh/kg could be evaluated for the whole system. (author) 4 figs., 1 tab., 5 refs.
1999-08-01
Development of a greenhouse-type solar dryer for medicinal plants and herbs
Energy Technology Data Exchange (ETDEWEB)
The economy of medicinal plant production is burdened considerably by the energy costs of drying. To substitute fossil energy, a solar heated dryer was developed, taking a plastic film greenhouse as superstructure to lower the initial costs. The solar air heaters, being incorporated into the roof, consist of a black absorber tissue, which is placed between the transparent cover of the greenhouse and an insulating air-bubble foil. To obtain a modular design, the system is structured along the ridge into segments of 2 m width. Each segment forms an independent solar air heater/batch dryer unit and is operated by a fan with a power consumption of 500 W. A prototype was tested in Yugoslavia, drying mint, sage and hops. (author).
1989-01-01
Willingness to pay for energy-saving measures in residential buildings
Energy Technology Data Exchange (ETDEWEB)
This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)
2008-03-15
Transportation energy data book: Edition 12
Energy Technology Data Exchange (ETDEWEB)
The Transportation Energy Data Book: Edition 12 is a statistical compendium prepared and published by Oak Ridge National Laboratory under contract with the Office of Transportation Technologies in the Department of Energy. Designed for use as a desk-top reference, the data book represents an assembly and display of statistics and information that characterize transportation activity, and presents data on other factors that influence transportation energy use. The purpose of this document is to present relevant statistical data in the form of tables and graphs. Each of the major transportation modes--highway, air, water, rail, pipeline--is treated in separate chapters or sections. Chapter 1 compares US transportation data with data from seven other countries. Aggregate energy use and energy supply data for all modes are presented in Chapter 2. The highway mode, ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction between coating system and basic material ...
2004-07-01
Phantom and animal imaging studies using PLS synchrotron X-rays
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...
2001-01-01
Some significant environmental issues in high-rise residential building design in urban areas
Energy Technology Data Exchange (ETDEWEB)
Almost in all the major cities in Asian countries, residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. While the wide use of air-conditioning helped to improve thermal comfort, health problems associated with poor indoor air qualities have appeared more frequently. The increased energy consumption is also a great concern in view of its impact on the energy economics of the region. Drawn from some of the onsite measurements and survey, and also the author's personal observation, some of the key issues are discussed in this paper. (author)
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
In the frame of the comprehensive assessment of Swiss energy systems, air quality simulations were performed by using a 3-dimensional photo-chemical dispersion model. The objective is to investigate the impacts of pollutants in Switzerland for future options of Swiss energy systems. Four scenarios were investigated: Base Case: simulations with the projected emissions for the year 2030, Scenario 1) all nuclear power plants were replaced by oil-driven combined cycle plants (CCP), Scenarios 2 to 4) traffic emissions were reduced in whole Switzerland as well as in the cities and on the highways separately. Changes in the pollutant concentrations and depositions, and the possible short-term impacts are discussed on the basis of exceedences of critical levels for plants and limits given to protect the public health. (author) 2 figs., 7 refs.
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
The Electric Fuel zinc-air battery yielded energy densities from 6.8 to 10.2 times higher than those of the lead-acid batteries. The higher the power and the more difficult the driving cycle, the higher this ratio of energy densities grew. Not only was the Electric Fuel battery capable of extended high-power discharge, the impact of such discharge conditions on energy and driving range was show to be quite small, and was much smaller than the comparable impact on lead-acid traction batteries. At the time of writing this paper, tests are scheduled to continue with the 110-kWh battery in the Mercedes van, and preliminary plans have been made for testing of additional batteries on other vehicle types.
1993-11-01
British Library Electronic Table of Contents (United Kingdom)
The objective of this study is to analyze the effects of heat loss characterized by a percentage of the fuel's energy, friction and variable specific heats of working fluid on the performance of an air standard Otto cycle with a restriction of maximum cycle temperature. A more realistic and precise relationship between the fuel's chemical energy and the heat leakage that is based on a pair of inequalities is derived through the resulting temperature. The variations in power output and thermal efficiency with compression ratio, and the relations between the power output and the thermal efficiency of the cycle are presented. The results show that the power output as well as the efficiency where maximum power output occurs will increase with increase of the maximum cycle temperature. The temp...
2008-01-01
Renewable energy technologies for federal facilities: Geothermal heat pump
Energy Technology Data Exchange (ETDEWEB)
This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.
1996-05-01
Drying of medicinal plants with solar energy utilization
Energy Technology Data Exchange (ETDEWEB)
In the paper, a potential of solar energy for drying of medicinal plants in Polish conditions is estimated and development of solar drying technologies is presented. The results of economic assessment of flat-plate solar collectors applied for drying of medicinal plants on a farm are promising. In some specific conditions, e.g. drying of wild grown medicinal plants in remote areas, even application of photovoltaic modules for driving of a fan of a solar dryer is a profitable option and enables easy control of the drying air temperature.
1997-10-01
Development of High-Efficiency Low-Lift Vapor Compression System - Final Report
Energy Technology Data Exchange (ETDEWEB)
PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.
2010-03-31
Desiccant cooling: parametric energy study
Energy Technology Data Exchange (ETDEWEB)
Desiccants have been used in many applications to provide dehumidification. This paper describes an application of desiccants which provide both dehumidification and sensible cooling, with little or no use of conventional vapour-compression refrigeration plant. Through a parametric study, the energy consumption and costs of a desiccant cooling system are compared with those of a conventional vapour-compression refrigeration-based air-conditioning system. (author)
1998-12-31
Combined cycles and combined energy systems for a safe and sound environment and life
Energy Technology Data Exchange (ETDEWEB)
Discussion is presented of world CO{sub 2} emissions and the effect rising population and population distribution has on this. Possible ways of decreasing emissions are presented, including potential for heat recovery, exhaust-air purification as an energy supply, shared power supply in industry, the use of cogeneration, and multiple use of heat in industry. 9 refs., 10 figs., 3 tabs.
1992-01-01
A new control strategy for tracking peak power in a wind or wave energy system
Energy Technology Data Exchange (ETDEWEB)
This paper proposes a novel control strategy for tracking peak power in a wind or wave energy system using a squirrel cage induction generator. It eliminates wind speed measurement or estimation and uses a simple scalar technique by exploiting the cubic nature of the power curve. The method works even when air velocity is varying dynamically. (author)
2009-06-15
International Nuclear Information System (INIS)
This Statistical Report presents results from the physical Swedish Environmental and Economic Accounts for the years 1993 and 1995 according to the classification NACE. The Environmental Economic Accounts constitute an integrated and comprehensive system for environmental and economic statistics. Environmental data are systematically presented together with economic data in a common framework. The system can be used for analyses of various relationships between economy and environment. Data on emissions to air of carbon dioxide, sulphur dioxide, nitrogen oxides, carbon monoxide, methane, nitrous oxide and ammonia are presented for 39 industries, government services and private consumption. The use of energy commodities in monetary and physical terms are also presented for the same sectors. Economic, energy and emission data are also presented in environmental and economic profiles and indicators. Environmental and economic ...
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
Thin, lightweight, and flexible gas-diffusion electrodes (GDEs) based on freestanding entangled networks of single-walled carbon nanotubes (SWNTs) decorated with Ag nanoparticles (AgNPs) are tested as the air-breathing cathode in a zinc-air battery. The SWNT networks provide a highly porous surface for active oxygen absorption and diffusion. The high conductivity of SWNTs coupled with the catalytic activity of AgNPs for oxygen reduction leads to an improvement in the performance of the zinc-air cell. By modulating the pH value and the reaction time, different sizes of AgNPs are decorated uniformly on the SWNTs, as revealed by transmission electron microscopy and powder X-ray diffraction. AgNPs with sizes of 3-5 nm double the capacity and specific energy of a zinc-air battery as compared with bare SWNTs. The simplified, lightweight architecture shows significant advantages over ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes zinc-air battery for electric vehicle (EV). This battery is composed of air electrode, zinc electrode, and alkali electrolyte. During the discharge, oxygen taken from the air is reduced at the air electrode, and zinc is dissolved at the zinc electrode. The whole reaction is formation of zinc oxide from oxygen and zinc. This is taken out to use as a secondary battery through exchange and regeneration, which is called mechanical charge. For Electric Fuel, discharged products in the zinc electrode from a spent EV are extracted by a vibrating crusher, and are dissolved in KOH to prepare zinc ion electrolyte. Thus, zinc is obtained through the electrolytic refining. Since the regenerated zinc is separated from the electrolytic electrode as a form of dendritic powder, it is recovered, treated by press molding, regenerated, and used as a zinc electrode. The battery developed by Electric ...
1998-05-05
New facility design and work method for the quantitative fit testing laboratory. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated ...
1989-05-01
Energy Technology Data Exchange (ETDEWEB)
The indoor climate of school buildings have been much debated recently. Many problems connected with air quality and thermal comfort are caused by bad maintenance, fitted carpets and no sunshades. Mechanical ventilation in schools has gained a bad reputation and many municipalities are seeking other solutions when building new schools. Natural ventilation according to the ''Swedish model'' does not use air filters or heat recovery from the outgoing air and achieve low energy consumption by reducing the airflow substantially in cold weather. Most of the naturally ventilated schools have supply air culverts of concrete below ground outside the building and in the basement. This is also true of schools using hybrid ventilation, where natural and mechanical ventilation is combined. The naturally ventilated schools often use manual control of the ...
2000-07-01
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...
2006-03-01
Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the productivity of the unit is strongly influenced by ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the productivity of the unit is strongly influenced by ...
2004-05-01
British Library Electronic Table of Contents (United Kingdom)
Tailor die quenching in the hot stamping of quenchable steel sheets was developed to produce ultra-high strength steel formed parts having strength distribution. Local portions of the heated sheet were quenched by holding grooved tools at the bottom dead centre during the stamping. Non-contact portions were generated in the sheet by grooving the tools, and thus the strength in the contact portions is high owing to the quenching and that in the non-contact portions is low owing to the lack of the quenching. Hat-shaped products having a tensile strength of approximately 1.5GPa only at four corners were formed.
2010-01-01
Mechanical properties and structure of low-alloy ultra-high strength steels
Energy Technology Data Exchange (ETDEWEB)
Mechanical properties of P-LDHA and V-ROL N steels of the Czech production are compared with other ultra-high strength steels produced in the world. The most important results can be summarized into following points: 1. Optimally heat treated P-LDHA steel exhibits substantially better strength characteristics then the V-ROL N steel. 2. Optimal tempering temperature of the P-LDHA steel is 300 C. 3. Basic mechanical properties of P-LDHA steel belong to the top of the UHS steels ranking and are well comparable with those of American 300 M steel. 4. In the low-cycle fatigue region, the P-LDHA steel exhibits slightly better fatigue resistance then the 300 M steel. On the other hand, the high-cycle fatigue resistance of 300 M steel is slightly better then that of the P-LDHA steel. (orig.)
2000-07-01
International Nuclear Information System (INIS)
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
2003-01-22
Energy Technology Data Exchange (ETDEWEB)
Ventilation systems must ensure high room air quality with minimum energy consumption in all states of operation. Systems for ventilation on demand are increasing their market share. (orig./MSK) [Deutsch] Oberste Aufgabe von Raumlufttechnischen Anlagen ist die Sicherstellung guter Raumluftqualitaet bei minimalem Energieverbrauch unter allen Betriebsbedingungen. Um dieses Ziel zu erreichen, setzt sich am Markt zunehmend die bedarfsgeregelte Lueftung durch. (orig./MSK)
1997-11-01
The secondary slurry-zinc/air battery
Energy Technology Data Exchange (ETDEWEB)
The rechargeability of the slurry-Zn/air battery was demonstrated with a practical recharge cell that requires minimal hydraulic and mechanical energy for operation. A dendritic Zn was deposited on a Mg plate substrate from which it was easily, periodically and automatically scraped to regenerate dendritic Zn slurries. Excellent discharge results were obtained with the regenerated dendritic Zn slurry, comparable to those obtained with slurries made with mixtures of Zn powder. The dendritic Zn slurry allowed, however, twice the utilization of Zn. 13 refs., 24 figs., 2 tabs.
1989-07-01
Energy Technology Data Exchange (ETDEWEB)
This invention is concerned with a solar energy system for propelling aircraft. Obtained are forces for aerodynamic lift and impetus. The lifted body had a transparent upper surface for the sun light, but black or reflecting for IR-radiation and high thermal insulation properties. Inside of the lifted body, the air temperature increases and is lifted by convection influence. The air resistance of this body is low in horizontal direction and higher in vertical position. The payload could be shifted, so that the positive or negative angle of the whole body can be selected. By this principal it is possible to transform the static lifting force in a dynamic impetus.
1981-07-30
Heat recovery in polyester production: a case study
Energy Technology Data Exchange (ETDEWEB)
Energy savings in the synthetic fiber industry could be realized by using autoclave reactor condensate and boiler flue gas heat recovery. The non-cellulose (polyester) production process analysis shows that condensate returning from the reactor to the steam boiler raises inlet temperature, giving a reduced fuel requirement of about 8%. Also, boiler flue gas with a sufficiently high outlet temperature for boiler feed water and combustion air preheating results in further fuel savings. The process with an economizer saves up to 8.44%, and with a combustion air preheater, 6.25%. (Author)
1997-07-01
Development and cycle test of zinc-oxygen cells
Energy Technology Data Exchange (ETDEWEB)
For the development of a rechargeable zinc/air battery, La{sub 0.6}Ca{sub 0.4}CoO{sub 3}-catalyzed (perovskite) bifunctional oxygen electrodes and pasted zinc electrodes were prepared and tested in monopolar zinc/air cells. The cells were cycled in moderately alkaline electrolyte. The maximum power as well as the cycle life of the cells were investigated. Up to 450 cycles could be reached, and attractive specific energies and powers were obtained. (author) 3 figs., 4 refs.
1995-07-01
Design parameters for tube cavity receivers in solar power plants
Energy Technology Data Exchange (ETDEWEB)
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
1981-01-01
International Nuclear Information System (INIS)
Recycling of used battery for recovering lead done by either small household/small scale industries has been identified as a source of air pollution, especially by heavy metal (Pb). This condition give an adverse impact toward workers and societies. Technological aspect is one of the causal. The process apply an open system. Therefore, a lot of energy, as well as dust wasted to the air without prior treatment. For overcoming this condition, closed system by utilizing Cupola furnace will be offered as one of the alternatives clean technology application and to increase the recovering performance in order to set an effective and efficient result. (author)
2000-02-01
Alkaline rechargeable zinc-air battery; Alkalische wiederaufladbare Zink-Luft Batterie
Energy Technology Data Exchange (ETDEWEB)
Because of its high energy density, compatibility with aqueous electrolytes and the low toxicity of its active materials, the zinc-air battery system is an interesting candidate for electric vehicle applications. The use of O{sub 2} from the air as a reactant requires a partially open cell construction and a technologically challenging air interface. This report describes the research and development program at the Paul Scherrer Institute which finally led to the demonstration of a durable, electrically rechargeable zinc-oxygen battery. In a first phase the research program was focused on the development of bifunctional oxygen diffusion electrodes and pasted zinc electrodes. The current-potential behaviour and the cycle life performance of anodes and cathodes was tested in single electrode measurements (three-electrode arrangements) as well as in complete monopolar zinc-oxygen and ...
1996-11-01
Thermal gradient humidification-dehumidification desalination system
Energy Technology Data Exchange (ETDEWEB)
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative ...
1982-12-14
Energy Technology Data Exchange (ETDEWEB)
In the international study of IEA Annex 27 `Demonstration and evaluation of domestic ventilation systems` a number of simple tools to gain insight into the characteristics of ventilation systems for dwellings are presented. The assessment is made with respect to e.g. indoor air quality, comfort, noise, energy, costs and reliability. In three articles the results of Annex 27 will be discussed. In the first article background information of IEA Annex 27 was given as well as applications in the Netherlands. In this second article attention is paid to the assessment models (`simplified tools`) for indoor air quality, thermal comfort and noise. 6 refs.
1999-09-01
British Library Electronic Table of Contents (United Kingdom)
Displacement Ventilation (DV) offers a great opportunity to improve indoor air quality while reducing the energy consumption compared to mixing ventilation. A frequent problem with displacement ventilation is however the draft discomfort caused by the cold air movement at foot level and excessive temperature difference between head and ankle. Despite numerous past studies, there is still a lack of detailed data regarding the velocity and temperature distribution inside DV jets. In this experimental study, measurements of the air velocity and temperature are performed in the DV jet produced by a flat wall-mounted DV diffuser, using a fine mesh focused on the 0.00-0.20 m height range. Two supply conditions are studied. Three planes of measurements are covered: the vertical longitudinal plane...
2012-01-01
Energy storage for hybrid remote power systems
Energy Technology Data Exchange (ETDEWEB)
Energy storage can be a cost-effective component of hybrid remote power systems. Storage serves the special role of taking advantage of intermittent renewable power sources. Traditionally this role has been played by lead-acid batteries, which have high life-cycle costs and pose special disposal problems. Hydrogen or zinc-air storage technologies can reduce life-cycle costs and environmental impacts. Using projected data for advanced energy storage technologies, LLNL ran an optimization for a hypothetical Arctic community with a reasonable wind resource (average wind speed 8 m/s). These simulations showed the life-cycle annualized cost of the total energy system (electric plus space heating) might be reduced by nearly 40% simply by adding wind power to the diesel system. An additional 20 to 40% of the wind-diesel cost might be saved by adding hydrogen storage or zinc-air fuel cells ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
Chemical looping combustion is a novel technology that can be used to meet the demand on energy production without CO{sub 2} emission. To improve CO{sub 2} capture efficiency in the process of chemical looping combustion of coal, a prototype configuration for chemical looping combustion of coal is made in this study. It comprises a fast fluidized bed as an air reactor, a cyclone, a spout-fluid bed as a fuel reactor and a loop-seal. The loop-seal connects the spout-fluid bed with the fast fluidized bed and is fluidized by steam to prevent the contamination of the flue gas between the two reactors. The performance of chemical looping combustion of coal is experimentally investigated with a NiO/Al{sub 2}O{sub 3} oxygen carrier in a 1 kW{sub th} prototype. The experimental results show that the configuration can minimize the amount of residual char entering into the air reactor from the fuel reactor with the external ...
2010-05-15
The green power option to gain market advantage
Energy Technology Data Exchange (ETDEWEB)
Deregulation of the electric power industry in Alberta holds the prospect of providing greater choice for customers. One such option will be `green power` which is provided by renewable energy technologies. The energy produced would be without environmental impacts such as air emissions, water pollution, flooding, thermal emissions or waste by-products. Wind power, small scale hydro power, photovoltaics and biomass technologies have been termed as `green power`. The choices that customers make will not be focused on price alone. Market forces are emerging to demand reduction in emissions which will result in a market for `green energy` products and facilitate achieving goals for a sustainable future.
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.
1989-03-01
Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy
Energy Technology Data Exchange (ETDEWEB)
Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)
2007-04-01
A theoretical evaluation of solar-powered desiccant cooling in the United Kingdom
Energy Technology Data Exchange (ETDEWEB)
Desiccant cooling is a potentially environmentally friendly technology that can be used to condition the internal environment of buildings. Unlike conventional air conditioning systems, which rely on electrical energy to drive the cooling cycle, desiccant cooling is a heat-driven cycle. This paper follows on from an initial study by the authors, and uses real meteorological data to evaluate the potential in the United Kingdom of using solar energy to drive the desiccant cooling cycle. Through the use of parametric studies, the paper investigates the energy consumption and costs associated with desiccant cooling. (author)
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
A closed economic system was assumed for the Veneto Region (Italy) in order to define an appropriate input-output model and assess the future economic and environmental impacts of proposed actions for energy source development and economic growth. Present and forecasted energy demands (to the year 2000) were determined by energy source, e.g., natural gas, coal, petroleum and hydropower for the different consuming sectors - agriculture, transportation, industry, etc. Forecasts were made of the air pollution expected as a result of different types of energy and technology inputs for each sector. These considered planned retrofits towards clean combustion systems. Costs were estimated for the implementation of proposed pollution abatement measures, as well as, for the effects of energy use related environmental damage and measures to restore the environment. Some ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this paper is to present and evaluate control strategies for adjustment and preservation of air quality, thermal and visual comfort for buildings' occupants while, simultaneously, energy consumption reduction is achieved. Fuzzy PID, fuzzy PD and adaptive fuzzy PD control methods are applied. The inputs to any controller are: the PMV index affecting thermal comfort, the CO{sub 2} concentration affecting indoor air quality and the illuminance level affecting visual comfort. The adaptive fuzzy PD controller adapts the inputs and outputs scaling factors and is based on a second order reference model. More specifically, the scaling factors are modified according to a sigmoid type function, in such a way that the measured variable to be as closer as possible to the reference model. The adaptive fuzzy PD controller is compared to a non-adaptive fuzzy PD and to an ON-OFF one. The comparison criteria are the ...
2001-07-01
Low energy, low emissions: SO_2, NO_x and CO_2 in Western Europe. Working paper
International Nuclear Information System (INIS)
A link is made in this paper between proposed low energy scenarios for different Western European countries and the amount of pollutants that may result from these scenarios. Air pollutant emissions are calculated for the ten countries for which low energy scenarios are available. These scenarios emphasize stringent energy efficiency, maximizing the use of renewable (other than nuclear) energy, and minimizing the use of fossil fuels. Under these low energy scenarios, the average per capita energy use (year 2030) in the ten countries is estimated as 97 GJ/person, which is a decrease of 38% relative to 1980. Using the energy consumption figures from the low energy scenarios, together with sector- and fuel-specific emission factors from Europe, the resulting emissions of SO_2 , NO_x , and CO_2 were ...
International Nuclear Information System (INIS)
Interest to thin film of metals' silicides first of all is conditioned intrinsic al them unique physical properties. On their basis of it is possible to produce extremely sophisticated devices of solid-state electronics, production which needs the controlled change of physics, chemical and electrical properties with high-level of accuracy. On the present time most are in detail investigated composition, structure and properties of three-dimensional samples of metals' silicides. In the last years the intensive are led to researches in the direction of creation and study of physical-chemical properties thin (500-1000 Angstroms) and ultrafine (100-120 Angstroms) films silicides. It has information about composition, morphology of surface and emission of properties of thin film of silicides of barium, of cobalt and of palladium, was obtained in conditions of ultra-high vacuum. Low energy ion implantation and further annealing on composition, ...
Reducing energy costs of plastics processing
Energy Technology Data Exchange (ETDEWEB)
Ways of reducing energy consumption in plastics processing are examined. Examples are given which illustrate how the awareness of everyone in the company to energy saving is essential with particular reference to switching arrangements to ensure such things as lights, machinery, compressed air systems are switched off when not needed or run at a lower level where appropriate. An understanding of the various elements of the electricity bill can inform a company`s planning of its operations to take advantage of lower tariffs. Machinery selection both with regard to efficiency of processing, quality of engineering and appropriate size can achieve significant savings and attention to maintenance is important. Fundamental to all aspects of energy saving is the monitoring of energy usage to identify where savings can be made and to evaluate the effectiveness of any measures taken. (UK)
1995-02-01
Techno-economic investigation of an air humidification-dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
This article presents a humidification-dehumidification (H.D.) process suitable for desalination of sea- and brackish water. The work correlated performance characteristics of the combination of different components in such a loop. Water yield, energy requirement and design data are evaluated as functions of different parameters. The investigation covered water to air mass ratios ranging from 60 to 80, concentration ratios between 2 and 5, at a temperature difference of between 10 and 16 C, along the liquid for dehumidification. The results showed that 76% of energy consumed in the humidifier is recovered by condensation. Increase of the concentration ratio to 5 can reduce the make-up water and rejected brine by about 58% and 24% respectively. Cost calculations show that the H.D. process has significant potential as an alternative for small capacity desalination plants and permits to operate systems as small as 10 m[sup ...
1993-08-01
Some characteristics of a novel direct thermal to optical energy converter medium
Energy Technology Data Exchange (ETDEWEB)
We have measured some of the optical characteristics of a novel energy conversion medium, over a range of compositions in the system Yb[sub 2]O[sub 3][minus]Al[sub 2]O[sub 3], which we have fabricated by a proprietary process. These specimens have good resistance to thermal shock, are durable, and are mechanically and chemically stable. The integrated emission of light generated by these unoptimized specimens when heated with a propane-air flame and detected with a silicon photodetector ranged up to 1.88 watts/cm[sup 2]. The emission spectrum from these specimens when heated with a propane-air flame and detected with a germanium photodetector shows a narrow band in the vicinity of 1 micron.
1995-01-05
International Nuclear Information System (INIS)
An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.
2006-01-01
Materials for air turbines in wave power devices. A generic study
Energy Technology Data Exchange (ETDEWEB)
Wave energy device teams have identified three varieties of air turbine as potentially applicable to wave energy devices. These are: conventional axial turbines; Wells, or self-rectifying, axial turbines and Francis turbines. This report examines the constructional requirements of these devices with regard to mechanical, environmental and manufacturing considerations. It is concluded that the major benefit of optimum material selection will be reduced manufacturing costs rather than enhanced turbine performance. A methodology of material selection has been established and candidate materials have been listed for the major components of each turbine type. Comparative costs for alternative materials are included, from which significant, potential economies have been identified. Recommendations are made aimed at achieving optimum material usage in the proposed turbines.
1981-01-01
Utility applications program. Annual report for 1981
Energy Technology Data Exchange (ETDEWEB)
The purpose of the Utility Applications Program is to provide information and assistance to interested utilities on central station energy storage systems. Compressed air and underground pumped hydroelectric energy storage are the primary technical focus. Smaller utilities are the primary targets of this program, as they may not have resources to track and utilize new energy conservation developments. The program, initiated during this year-long period, consists of a series of tasks integrating and supporting energy storage implementation. Program management and technical coordination activities monitor the wide range of research ongoing both under government support and in industry and provide a locus for dissemination of results. Recently completed DOE demonstration studies provide the central data base and the DOE CAES and UPH Technology Program activities provide another major ...
1982-06-01
Structure and properties of high-performance polymeric and carbon fibers - an overview
Energy Technology Data Exchange (ETDEWEB)
In this paper structure and mechanical properties of PBZT and PBO fibers are briefly discussed. One limitation of the high-modulus polymeric fibers and ultrahigh-modulus carbon fibers in reinforced composites is their poor compressive strength. Issues related to the compressive strength of polymeric and carbon fibers are considered. 62 references, 7 figures, 4 tables.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)
2008-05-15
PV Conversion Technologies, Session: OPV, Sensitized, Seed (Presentation)
Energy Technology Data Exchange (ETDEWEB)
The NREL Sensitized Solar Cell (SSC) Core Program supports the Solar America Initiative by: (1) targeting new devices and processes for commercialization by 2015 that are less expensive, more efficient, highly reliable, and environmentally benign; (2) collaborating with DOE OS/BES to conduct basic research targeting breakthroughs in key areas, such as ultra-high efficiency and/or ultra-low cost materials and devices.
2008-04-01
Development of Bulk Nanocrystalline Cemented Tungsten Carbide for Industrial Applicaitons
Energy Technology Data Exchange (ETDEWEB)
This report contains detailed information of the research program entitled "Development of Bulk Nanocrystalline Cemented Tungsten Carbide Materials for Industrial Applications". The report include the processes that were developed for producing nanosized WC/Co composite powders, and an ultrahigh pressure rapid hot consolidation process for sintering of nanosized powders. The mechanical properties of consolidated materials using the nanosized powders are also reported.
2009-03-10
Energy Technology Data Exchange (ETDEWEB)
In many facilities, energy management is simply a matter of managing the energy required for lighting and space conditioning. In many others, however, energy management is much more complex and involves large motors and controls, industrial insulation, complex combustion monitoring, unique steam distribution problems, significant amounts of waste heat, etc. Typical facilities offering large energy management opportunities include industrial facilities, large office and commercial operations, government institutions such as schools, hospitals and prisons. Such facilities generally have specialized industrial, commercial or institutional processes that incorporate many of the concepts covered in other chapters. These processes require thorough analytical evaluations to determine the appropriate energy-saving measures. This chapter provides some examples. In this chapter the authors ...
1994-12-31
Economic policy instruments for the control of air pollution in Poland
International Nuclear Information System (INIS)
The World Bank is analyzing the role of economic policy instruments for the control of air pollution in Poland, in cooperation with Polish and international experts. The first stage, covering Poland as a whole, was recently completed, jointly financed with the U.S. E.P.A. and the Government of the Netherlands. The second stage, now under way, will extend the analysis into a specific regional framework. Stage 2 is financed by the World Bank, the Polish Government, and the U.K. Environment Know-How Fund. Air Pollution in Poland is overwhelmingly caused by energy production and uses, due to the fact that the Polish economy depends heavily on coal and lignite. At present, vehicles contribute less to total emissions than do coal burning and industrial processes, although they account for 25-35% of nitrogen oxides, carbon monoxide, hydrocarbons and lead; and the concentrated in areas of high population density. The paper shows ...
1993-06-13
Surface wettability effect on an indirect evaporative cooling system
Energy Technology Data Exchange (ETDEWEB)
Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A dynamic contact analyzer was used to quantitatively measure ...
1996-11-01
Performance analysis on a hybrid air-conditioning system of a green building
Energy Technology Data Exchange (ETDEWEB)
This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by ...
2006-05-15
Feasibility study of a new zinc-air battery concept using flowing alkaline electrolyte
Energy Technology Data Exchange (ETDEWEB)
Proof-of-principle experiments are reported for a new concept in electrically rechargeable zinc-air battery. The zinc electrode is a porous flow-thru type using a copper foam metal substrate with zinc deposition onto the foam metal from concentrated zincate electrolyte (as used in zinc-slurry type batteries). The bifunctional air electrode employs low-cost materials, being fabricated entirely from carbon-based precursors and small amounts of nickel and/or cobalt oxide. Corrosion measurements on the graphite materials in the air electrode indicate sufficient corrosion resistance for 8000 h life on charge. A prototype single cell was constructed having 1.5 Ah capacity producing 1.2 V discharge -2.0 charge at the three hour rate and has produced stable voltages for more than 150 cycles. Based on the 1.5 Ah prototype characteristics, design calculations for a 32 kWh battery project an energy density of ...
1986-04-01
Catalytic oxidation of the unburnt fuel for the efficient production of electric energy
Energy Technology Data Exchange (ETDEWEB)
Modern combined cycle power plants with natural gas as the only fuel reach efficiencies of up to 58% for electric power generation. Nevertheless the reserves of natural gas are more limited compared to the reserves of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverised coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide and unburnt carbon to carbon dioxide ...
1995-12-31
Performance testing of selected types of electronic personal dosimeters used in Sudan
International Nuclear Information System (INIS)
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
2010-12-01
Storage of electric energy gained from renewable sources
Energy Technology Data Exchange (ETDEWEB)
This paper discussed issues related to the storage of electricity produced from renewable energy sources. Storage systems currently used by distribution systems were reviewed. The study showed that successful storage systems ensure high charging and discharging rates for shorter periods of time. Systems with high storage capacities must also be able to store energy for longer periods of time than traditional energy storage systems. Systems include pumped storage plants; electro-chemical accumulators; compressed air accumulators; and redox flow batteries. Hydrogen technologies for the storage of electric energy from renewable sources were reviewed. The paper also outlined energy storage and fuel cell research currently being conducted by researchers in the Czech Republic. The study concluded by stating that new energy storage technologies are ...
2009-03-11
Postulated weather modification effects of large energy releases
International Nuclear Information System (INIS)
Postulated impacts of large energy releases were examined in the light of existing technical information. The magnitudes of direct atmospheric modifications were estimated, and the ecological and economic implications of the modifications were explored. Energy releases from energy centers (10 to 40 power plants at a single site) and individual power plant clusters (1 to 4 power plants) were considered. In the atmosphere the energy will exist initially as increased temperature (sensible heat), moisture (latent heat), and air motion (kinetic energy). Addition of energy could result in increased cloudiness and fog, and changed precipitation patterns. A framework for economic analysis of the impacts of the postulated atmospheric modifications was established on the basis of costs and benefits. Willingness-to-pay was selected as the appropriate ...
1977-01-01
Field performance of an energy pile system for space heating
Energy Technology Data Exchange (ETDEWEB)
This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance for space heating was quite high at 3.9, and the seasonal primary ...
2007-05-15
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Gasification of waste from furniture industries for generation of sustainable energy
Energy Technology Data Exchange (ETDEWEB)
The global interest in renewable energy is attributed to the decline in fossil fuel sources and the need for technical, economic, social and environmental sustainability. This study focused on the new techniques that have been developed for the use of biomass for energy from wood wastes from the forest-based industry. As an energy source, wood waste contributes positively to the environment by reducing environmental problems related to contamination of soil, air and water through improper disposal of waste. Biomass gasification has the advantage of converting biomass into a combustible gas that can be used for heat generation, electricity and synthesis of chemicals. Syngas produced from gasification of eucalyptus residues has significant potential, with an average High Heating Value of 6.60 MJ/m{sup 3}, and regular composition during the process, with predominance of carbon monoxide, followed by ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
This report discusses environmental surveillance activities conducted on the Nevada Test Site during the first calendar quarter of 1996. Surveillance activities included collection and analysis of air, noble gas, tritiated water vapor, and other water samples. Samples were analyzed for both radiological and non-radiological effluents.
1996-11-01
The building tomorrow and after..; Le batiment demain et apres-demain..
Energy Technology Data Exchange (ETDEWEB)
During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)
1998-01-01
International Nuclear Information System (INIS)
An apparently significant result in an experiment to search for tachyons in the interval of time immediately preceding in the arrival of air showers of energy approximately 10"1"5 eV is considered. Several similar experiments have been completed, all of which have yielded null results. The original data of the foregoing reference have been re-examined and it is shown that an artifact of the apparatus was contributing to the original apparently significant results. (orig./BJ).
Energy Technology Data Exchange (ETDEWEB)
HEW is operating one of the biggest district heating networks of the Federal Republic of Germany. The paper discusses a number of projects which in recent years have been engaged in extensive air pollution abatement measures to make district heating an environmentally compatible energy source. Emphasis is placed on the hot gas cleanup system of block 2 of the harbor power plant. The system is the first of its kind to have realized an SCR system connected with the desulfurization system for industrial denitrification purposes.
1988-01-01
Green design focus: Energy efficiency and environmental responsibility
Energy Technology Data Exchange (ETDEWEB)
This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.
1998-02-01
Reengineering Air Mobility: A Process Perspective
Page 1. REENGINEERING AIR MOBILITY: A PROCESS PERSPECTIVE ... REENGINEERING AIR MOBILITY: A PROCESS PERSPECTIVE ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The Burrard Thermal Generating Station is located at Port Moody, British Columbia, and burns natural gas to supply steam to six turbine units for generating up to 912 MW of electricity. The Burrard plant accounts for ca 8.7% of the provincial generating capability. Burrard is expected to continue to fill a vital role as a supplier of displaceable firm energy to the British Columbia Hydro system. In parallel with a renewed focus on Burrard from a system planning perspective, there have also been concerns about air pollution from the plant in the context of its possible effect on the region's air quality. To address this and other issues surrounding Burrard's future, B.C. Hydro established a project team to conduct a utilization study. The team's work focused on the role of Burrard in providing a reliable and profitable role in electricity generation, the options for dealing with the ...
1993-01-01
Radionuclide air emissions report for the Hanford Site -- calendar year 1997
Energy Technology Data Exchange (ETDEWEB)
This report documents radionuclide air emission from the Hanford Site in 1997, and the resulting effective dose equivalent to the maximally exposed member of the public, referred to as the MEI. The report has been prepared in accordance with reporting requirements in the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. This report has also been prepared in accordance with the reporting requirements of the Washington Administrative Code Chapter 246-247, Radiation Protection-Air Emissions. The effective dose equivalent to the MEI from the Hanford Site`s 1997 point source emissions was 1.2 E-03 mrem (1.2 E-05 mSv), which is well below the 40 CFR 61 Subpart H regulatory limit of 10 mrem/yr. Radon ...
1998-06-17
State of the energy in Lebanon
International Nuclear Information System (INIS)
The article describes the state of the energy in Lebanon. In 1996, Lebanon consumed 4647 Ktoe as a primary energy. 97% of this energy is imported mainly polluting oil products: 1623 Ktons fuel-oil, 1379 Ktons gasoline, 930 Ktons diesel, 200 Ktons coal, 124 Ktons LPG, 107 Ktons jet-fuel/Kerosene, 109 Ktons Asphaltic products. The remaining 3% of the energy consumption is renewable energy. As for production, the state owns two refineries which are not used anymore. The year 2000 plan includes an expansion project for the Tripoli refinery and an alternative plan for the Zahrani refinery. These refineries require a total investment in order to reach a production capacity of 50000 barrels a day. The article is a description of the pollution type sources and location in Lebanon. The combustion of the total energy produces yearly more than 15 Ktons of dust, 85 Ktons of ...
1998-04-01
Office of Industrial Technologies: Summary of program results
Energy Technology Data Exchange (ETDEWEB)
Working in partnership with industry, the US Department of Energy`s (DOE`s) Office of Industrial Technologies (OIT) is helping reduce industrial energy use, emissions, and waste while boosting productivity. Operating within the Office of Energy Efficiency and Renewable Energy (EE), OIT conducts research, development, demonstration, and technology transfer efforts that are producing substantial, measurable benefits to industry. This document summarizes some of the impacts of OIT`s programs through 1997. OIT tracks energy savings as well as other benefits associated with the successfully commercialized technologies resulting from OIT-supported research partnerships. Specifically, a chart shows current and cumulative energy savings as well as cumulative reductions of various air pollutants including particulates, volatile organic compounds ...
1999-01-01
Measurement of electron energy fluence spectra from electron beam therapy machines
Energy Technology Data Exchange (ETDEWEB)
A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled ...
1984-01-01
TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR
Energy Technology Data Exchange (ETDEWEB)
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis ...
2010-03-01
International Nuclear Information System (INIS)
During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.
1991-10-31
The influence of bowl offset on air motion in a direct injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
The influence of bowl offset on motored mean flow and turbulence in a direct injection diesel engine has been examined with the aid of a multi-dimensional flow code. Results are presented for three piston geometries. The bowl geometry of each piston was the same, while the offset between the bowl and the cylinder axis was varied from 0.0 to 9.6% of the bore. The swirl ratio at intake valve closing was also varied from 2.60 to 4.27. It was found that the angular momentum of the air at TDC was decreased by less than 8% when the bowl was offset. Nevertheless, the mean (squish and swirl) flows were strongly affected by the offset. In addition, the distribution of turbulent kinetic energy (predicted by the /delta/-e model) was modified. Moderate increases (10% or less) in mass averaged turbulence intensity at TDC with offset were observed.
1988-01-01
Numerical analysis of methane-air combustion considering radiation effect
Energy Technology Data Exchange (ETDEWEB)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the experimental data than that of the case without radiation effect. (author)
2008-12-15
Numerical analysis of methane-air combustion considering radiation effect
International Nuclear Information System (INIS)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the experimental data than that of the case without radiation effect.
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
This illustrated final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project concerning a new, highly active oxygen reduction electrode for PEM fuel cell and zinc/air battery applications. The goal of this project was, according to the authors, to increase the efficiency of the oxygen reduction reaction by lowering the activation polarisation through the right choice of catalyst and by lowering the concentration polarisation. In this work, carbon nanotubes are used as support material. The use of these nanotubes grown on perovskites is discussed. Theoretical considerations regarding activation polarisation are discussed and alternatives to the use of platinum are examined. The results of experiments carried out are presented in graphical and tabular form. The paper is completed with a comprehensive list of references.
2008-04-15
Model for predicting air-fuel mixing and combustion for direct injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
Based on a multi-zone spray-mixing approach, an air-fuel mixing and combustion model for a Direct Injection Diesel engine is presented. The predictions from the model show very good agreement with the experimental data for various engines under a wide range of operating conditions. Major physical processes are modeled and validated independently. The atomisation process is based on Binary Drop Division concept. Fuel droplets are considered randomly distributed in the spray. A spherico-symmetrical transient drop evaporation model is used for evaporation calculation. A 3-dimensional spray-swirl interaction is modeled on centreline velocity vector/continuum approach. Turbulent mixing is characterised considering all possible available energy sources in DI diesel engines.
1986-01-01
Formation of particles in combustion of biofuels
International Nuclear Information System (INIS)
Biomass combustion is an important part in a sustainable energy system, but as well a source of submicron (particles < 1 #mu#m) particles in the air. Consequently, to obtain a good air quality together with increased biomass combustion there is a need for a better understanding of particle formation. This work is a part of a larger project about formation and emissions of particles from biofuel combustion. The report includes the work performed in the project during the year 2004. The aim of the project is to describe the release of inorganic components, which cause particle emissions, during combustion of single fuel particles of biofuel, e.g. wood pellets. The work is carried out by emission measurements, systematic combustion experiments and modelling work. The results are expected to contribute to the understanding of which parameters that influence the formation of fine particles and thus gain a better insight into ...
Experimental Investigation and RELAP5 Modeling of Two-Phase Flow in Horizontal Rectangular Channel
British Library Electronic Table of Contents (United Kingdom)
The investigation of steam, water, and air flow characteristics in horizontal channel is a part of major investigations program at the Lithuanian Energy Institute. The objective of this program is to identify condensation effects on two-phase flow stability and to predict conditions when rapid condensation could be induced in two-phase condensable flow. This article presents investigation of steam-water and air multiphase flow in nearly horizontal rectangular channel. The experimental data for pressure drop and interfacial and wall shear stresses in the channel with uniform distribution of void fraction are presented in this paper. Overall channel dimensions are length = 1.2 m, width = 0.02 m, height = 0.1 m; however, the test section was about 0.84 m in length. Three different flow types ...
2011-01-01
Exergy analysis of the solar multi-effect humidification?dehumidification desalination process
British Library Electronic Table of Contents (United Kingdom)
An exergy analysis method is presented of the solar multi-effect humidification?dehumidification desalination (HDD) process. Pinch technology is used in the humidification process to determine the maximum possible saturated air temperature and the temperature of water rejected from the unit, and then the dehumidification process to determine the temperature of water leaving from the heat exchanger. The formulae to calculate the exergy of water and saturated air are given. The solar plane collector is used. From exergy analysis, the solar collector has the lowest exergy efficiency; the HDD process has a lower exergy efficiency, and the water rejected has also a large exergy loss. The energy and exergy recovery rate of the desalination process is also lower. The solar multi-effect HDD proces...
2007-01-01
Design of a GaAs/Ge solar array for unmanned aerial vehicles
Energy Technology Data Exchange (ETDEWEB)
Unmanned Aerial Vehicles (UAV) are being proposed for many applications including surveillance, mapping and atmospheric studies. These applications require a lightweight, low speed, medium to long duration airplane. Due to the weight, speed, and altitude constraints imposed on such aircraft, solar array generated electric power is a viable alternative to air-breathing engines. Development of such aircraft is currently being funded under the Environmental Research Aircraft and Sensor Technology (ERAST) program. NASA Lewis Research Center (LeRC) is currently building a Solar Electric Airplane to demonstrate UAV technology. This aircraft utilizes high efficiency Applied Solar Energy Corporation (ASEC) GaAs/Ge space solar cells. The cells have been provided by the Air Force through the ManTech Office. Expected completion of the plane is early 1995, with the airplane currently undergoing flight testing using battery power.
1995-03-01
Energy Technology Data Exchange (ETDEWEB)
Examination is made of the main features of the physical and chemical preignition processes within homogeneous mixtures of air and gaseous fuels, such as propane, methane and hydrogen in a motored engine, while employing detailed chemical kinetics in a one zone analytical model. The changes in the compression temperature and pressure due to the admission of gaseous fuels, energy release during the preingition reactions and the contributions of heat transfer and residual gases to the preignition reaction activity were followed over a number of consecutive cycles until the occurrence of autoignition. Some of the observed differences in engine behaviour when operating on methane, propane and hydrogen were discussed with particular reference to the observed trends in dual fuel engine operation. Calculated results showed good agreement with some corresponding experimental trends. 14 refs., 9 figs.
1994-10-01
Energy Technology Data Exchange (ETDEWEB)
The kraft recovery boiler is of critical importance for the paper and pulp industry. From only energy point of view, kraft recovery boilers supply more than 50% of total thermal energy consumed in the paper and pulp industry. A kraft recovery boiler has two main functions: firstly to recover the inorganic cooking chemicals in the black liquor for reuse in the pulping process, and secondly to make use of the chemical energy in the organic portion of the black liquor to generate super-heated steam for the plant. The twin objectives of recovering chemicals and energy makes the recovery boiler design and operation more complex than virtually any other boiler application. Thus there is a demand for development of an analytical tool that can be used to predict the performance of a kraft recovery boiler. This paper presents the results achieved from a project jointly financed by Swedish National ...
2001-07-01
Load calculation and system evaluation for electric vehicle climate control
Energy Technology Data Exchange (ETDEWEB)
This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the best choices for EV HVAC. These are, vapor compression, ice storage and adsorption systems. These systems are evaluated, including calculations of ...
1994-09-12
APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)
Energy Technology Data Exchange (ETDEWEB)
The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)
2008-10-15
Who's In The Dark: Satellite Based Estimates Of Electrification Rates
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed to estimate the percent population having electric power access based on the presence of satellite detected nighttime lighting. A global survey was conducted for the year 2006 using nighttime lights collected by the U.S. Air Force Defense Meteorological Satellite Program (DMSP) in combination with the U.S. Department of Energy Landscan population dataset. The survey includes results for 229 countries and more than 2000 subnational units. The results are compared to reported electrification rates for 87 countries compiled from a variety of sources by the International Energy Agency. The DMSP derived estimate of number of people worldwide who lack access to electricity is 1.62 billion, only slightly larger than the 1.58 billion estimated by the International Energy Agency.
2011-01-01
The thermal response of an infinite line of open loop wells for ground coupled heat pump systems
British Library Electronic Table of Contents (United Kingdom)
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...
2011-01-01
Malaspina University-College's green building strategy
Energy Technology Data Exchange (ETDEWEB)
This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance ...
2000-01-01
Development of a portable thermophotovoltaic power generator
Energy Technology Data Exchange (ETDEWEB)
A 150 Watt thermophotovoltaic (TPV) power generator is being developed. The technical approach taken in the design focused on optimizing the integrated performance of the primary subsystems in order to yield high energy conversion efficiency and cost effectiveness. An important aspect of the approach is the use of a selective emitter radiating to a bandgap matched photovoltaic array to minimize thermal and optical recuperation requirements, as well as the non-recoverable heat losses. For the initial prototype system, fibrous ytterbia emitters radiating in a band centered at 980 nm are matched with high efficiency silicon photoconverters. The integrated system includes a dielectric stack filter for optical energy recovery and a ceramic recuperator for thermal energy recovery. The system has been operated with air preheat temperatures up to 1350K. The design of the system and development status are ...
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
2003-01-22
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is ...
2004-05-01
International Nuclear Information System (INIS)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is ...
2004-05-01
Numerical simulation of droplets deposition in a horizontal turbulent channel flow
In this dissertation, a two-phase, air-droplets, dilute, turbulent, and steady state flow in a horizontal rectangular channel, is modeled and numerically simulated using a modified KIVA-3V code. The deposition of different sizes of droplets on the walls of the channel is also studied. In this model, the interaction effects between the phases (two-way coupling) are considered by source terms in the momentum and energy equations for the continuous phase and by the instantaneous local velocity of the air in the droplet equation of motion, which includes the aerodynamic and gravitational forces. The turbulence is modeled by a k-? model. The interaction effects between the turbulence and the dispersed droplets are also taken into account. The effects of the turbulence on the droplets are modeled by a fluctuating component added to the local air velocity in the droplet equation of motion. The effects of the ...
1999-01-01
Air breakdown induced by a high-power short-pulse microwave
Energy Technology Data Exchange (ETDEWEB)
At Himeji Institute of Technology, the high power microwaves with the peak power of 20 MW, frequency of 12 GHz and pulse duration of 14 ns have been produced with a virtual cathode oscillator (vircator). These high power microwaves offer new applications in various fields. One problem in laser-triggered lightning experiment is the strong attenuation of laser energy by rain, cloud and laser-produced plasma. Microwaves propagate in thundercloud with small loss, and also are able to irradiate much extensive region of targets. In this paper, the fundamental experiment on the air breakdown induced by high power, short pulse microwaves is reported. The experimental setup of the vircator diode for microwave generation is shown. The typical evolution of diode voltage, electron beam current and microwave emission from the top in the course of time is shown. The experimental setup for microwave-induced air breakdown and the ...
1996-05-01
Extrinsic fracture mechanisms in two laminated metal composites
Energy Technology Data Exchange (ETDEWEB)
The crack growth behavior and fracture toughness of two laminated metal composites (6090/SiC/25p laminated with 5182 and ultrahigh-carbon steel laminated with brass) have been studied in both ``crack arrester`` and ``crack divider`` orientations. The mechanisms of crack growth were analyzed and extrinsic toughening mechanisms were found to contribute significantly to the toughness. The influence of laminate architecture (layer thickness and component volume function), component material properties and residual stress on these mechanisms and the resulting crack growth resistance are discussed.
1994-11-29
Explosives synthesis at Los Alamos
Energy Technology Data Exchange (ETDEWEB)
During the past two decades, the explosives synthetic effort at Los Alamos has been directed toward energetic heterocylic compounds and has produced some useful thermally stable explosives. The recent evolution of crystal-density predictive methods is guiding our current efforts toward ultrahigh performance explosives. Much of our effort is now on the development of new methods for preparing unique nitro compounds that are inaccessible by conventional techniques. This paper reviews the Los Alamos synthetic program with emphasis on the development of novel thermally stable explosives, and current efforts to synthesize high-density/performance explosives will be discussed.
1986-03-01
Energy Technology Data Exchange (ETDEWEB)
The study described in this report is part of a project sponsored by the Toronto Atmospheric Fund, performed at the Lawrence Berkeley National Laboratory, to assess the potential role of surface property modifications on energy, meteorology, and air quality in the Greater Toronto Area (GTA), Canada. Numerical models were used to establish the possible meteorological and ozone air-quality impacts of increased urban albedo and vegetative fraction, i.e., ''cool-city'' strategies that can mitigate the urban heat island (UHI), significantly reduce urban energy consumption, and improve thermal comfort, particularly during periods of hot weather in summer. Mitigation is even more important during critical heat wave periods with possible increased heat-related hospitalization and mortality. The evidence suggests that on an annual basis cool-city strategies are beneficial, and ...
2002-04-30
Canada vs. the OECD: an environmental comparison
International Nuclear Information System (INIS)
Canada's environmental performance is compared to the 28 other nations in the Organization for Economic Cooperation and Development (OECD). Twenty-five environmental indicators in ten categories are examined. These are: air, water, energy, biodiversity, waste, climate change, ozone depletion, agriculture, transportation and miscellaneous. Results show Canada with the poorest environmental record of all OECD countries, except the United States. The statistical information, compiled from data verified and published by the OECD, shows Canada among the worst three countries on nine indicators (per capita GHG emissions, CO and VOCs emissions, water consumption, energy consumption, energy efficiency, volume of timber logged, generation of nuclear waste, and the highest amount of energy consumed per unit of GDP). Tracking Canada's energy performance over the past two ...
Design of a 60 MW CFB gasification system (CGAS) for Uganda : utilising rice husks as input fuel
Energy Technology Data Exchange (ETDEWEB)
In Uganda, biomass comprises more than 95 per cent of the total energy supply. Agricultural residues are a major source of energy that can be converted into producer gas in biomass gasifiers. The high poverty levels in Uganda can be attributed in part to the fact that more than 90 per cent of the population does not have access to electricity due to limited and unreliable electricity produced in the country. A circulating fluidized bed (CFB) gasification system was designed in this study in order to generate a system for the effective use of agricultural wastes for energy production. Rice husks were used as the feedstock for a power output of 60 MW. The gasification system was designed using ERGUN CFB software with available theoretical and experimental data. The design comprises a reactor subsystem, air distribution plate, cyclone, air inlet and fuel feeding systems. The reactor is ...
2010-07-01
Efficient low-emission burners for natural gas domestic cooktops
Energy Technology Data Exchange (ETDEWEB)
Three new partially-aerated burners have been developed for Australian cooktops fired with natural gas, with maximum thermal inputs of 12, 7.5 and 5.5 MJ h{sup -1}. These novel burner designs minimise the NO{sub 2} emission per unit of useful energy, since NO{sub 2} is the more toxic nitrogen oxide of concern for indoor air pollution. They provide lower values of the ratio of NO{sub 2} emission to thermal efficiency than production burners, with respective reductions of 42, 13 and 23% compared with production burners of corresponding size. The traditional combustion diagrams of these prototype burners have been defined, on plots of primary aeration versus thermal input, to identify the regions of stable flame operation. However, the regions of satisfactory operation are further limited at low primary aeration by the Australian Gas Association requirement for CO/CO{sub 2} ratio <0.01 and at low thermal inputs by the requirement for ...
2000-03-01
Radionuclide Air Emissions Report for the Hanford Site Calendar year 1998
Energy Technology Data Exchange (ETDEWEB)
This report documents radionuclide air emissions from the Hanford Site in I998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR SI), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246-247, Radiation Protection--Air Emissions. The federal regulations in 40 CFR 61, Subpart H; require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 mrem/yr effective dose ...
1999-06-15
Solid fuels such as coal, wood, and crop straw supply some fraction of household cooking and heating fuel for more than one billion people in China. As these fuels do not generally combust cleanly in household stoves, their use levies large health and environmental burdens, particularly in rural regions. Production of clean-burning fuels from agricultural residue offers one prospect for mitigating health and social burdens imposed by household use of solid fuels. This dissertation explores the question: how might production of clean-burning household fuels from agricultural residues affect human health and social conditions in rural China? I approach this question from three perspectives. First, a technically plausible but currently unproven village-scale energy technology is explored in a scenario bounded by natural resources and substantiated by engineering specifications, estimates of indoor exposures to air pollution, and epidemiological ...
2005-01-01
S-N curves for welded tubular joints
Energy Technology Data Exchange (ETDEWEB)
The objective of the project was to develop a welded tubular joint database to assess the fatigue design curves (X and X{prime}) in the American Petroleum Institute design code (API RP2A). Changes in the curve-fitting method and screening criteria (primarily the exclusion of the very thin tubular joints) produced results different from those reported previously. The current results show that the X and X{prime} curves are too conservative and that a new curve should be adopted. The Department of Energy T{prime} curve was found to be consistent with the screened tubular joint air data and is recommended for use in API RP2A. The weldment size effect exponent (n) of 0.25 in the current version of API RP2A was found to be too small, and a higher value of 0.30 consistent with the Department of Energy recommendations is recommended. The fatigue test results for tubular joints tested in air and tubular joints ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Storing electrical energy in batteries is not a viable option for sustaining a country's energy economy. The mass and volume, as well as the costs, of electrochemical components required for this would be beyond all reason. Nevertheless, in certain applications the storage of electrical energy does have significant advantages over other technologies. For example, electrically powered road vehicles emit no exhaust fumes and very little noise at their place of operation. In this way they contribute substantially to air and noise pollution control in urban areas. Photovoltaic applications permit environmentally friendly electricity applications in places remote from the public grid where conventional solutions are prohibitively expensive. More than in the past, battery systems today have to meet a wide range of technical, economic and ecological requirements in order to be marketable. This is why ...
1997-02-01
Energy Technology Data Exchange (ETDEWEB)
A wind turbine is disclosed which permits high energy production over a wide range of wind forces while being protected against climatic hazards. According to the invention, a mast supports an energy recuperator comprising vane-type rotors by means of a frame which is orientable around a vertical axis. An energy conversion device is connected to the recuperator in order to be driven in rotation by the recuperator. The frame is responsive to the aerodynamic force exerted on the recuperator with respect to the mast and to the ground so as to optimize the power collected by the machine. The frame comprises a turret pivoted to the mast about the vertical axis and a structure pivoted to the turret about a horizontal axis of tilting motion. A balance weight maintains the recuperator in the top position when there is no wind. The aerodynamic drag of the recuperator acts in the opposite direction. In consequence, in the event of a ...
1991-12-19
Electrical wind generation, feasibility study and analysis in Lebanon
International Nuclear Information System (INIS)
Full text.This paper is to investigate the potentials and possibilities of electrical generation via wind turbine. Special attention is directed to the interpretation of wind generation characteristics and parameters found in Lebanon and linking the electrical energy to the Lebanese slectric grid. Although much of the wind energy research is very well established and boomed globally (USA, Europe, India and China), in Lebanon is never used. At a time when climate scientists are increasingly concerned about carbon dioxide emissions from coal and diesel plants, and the nuclear industry is drying, the significance of a major new source os electricity is clear. there are many motives and feasibility criteria for qind power generation in Lebanon. They include the need for increasing the Lebanese electrical capacity, reducing air pollution, alternative energy sources and prices and availability of oil. The ...
1999-11-02
Computational and experimental study of a railplug ignitor
Energy Technology Data Exchange (ETDEWEB)
The plasma plume generated by a new type of high energy Janitor known as the railplug, is examined. The railplug is a miniaturized railgun that has the potential for improving ignition characteristics of combustible mixtures in engines. The objective of the study is to gain an uderstanding of the characteristics of the plasma created by a transparent railplug, and to validate a multidimensional computer simulation of the plasma and shock fronts. The nature of the plume emitted by the railplug was examined for three levels of electrical energy while firing into air at a pressure of 1 atm. The computer model is to be used to predict trends in railplug performance for various railplug designs, energies, and ambient conditions. The velocity of the plasma movement inside a transparent railplug was measured, as well as the velocity of the plume ejected from the cavity. A shock is produced at the initiation ...
1992-01-01
Sensor test facilities and capabilities at the Nevada Test Site
Energy Technology Data Exchange (ETDEWEB)
Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced sensor systems for monitoring activities ...
1996-12-31
Impact of energy consumption on urban warming and air pollution in Tokyo metropolitan area
International Nuclear Information System (INIS)
The rapid progress of industrialization and urbanization due to economic growth and concentration of social function in the urban areas in Japan have had an adverse effect on the urban environment. In most cities, it has become evident that the increase in energy consumption is causing environmental problems, including a temperature rise in the urban atmosphere (urban heat island) and air pollution. This paper reports the results of field observations and three dimensional simulations of the urban heat island using a three-dimensional modelling vorticity-velocity vector potential formation, in the Tokyo metropolitan area. According to the simulation for urban warming in the study area for the year 2031, the maximum temperature of a summer evening (18:00) would exceed 43 degrees celsius, indicating that Tokyo would no longer be comfortable for its inhabitants. It is concluded that in the near future, the problem of the urban heat island will ...
1995-11-20
Energy Technology Data Exchange (ETDEWEB)
"What happens to conventional metals near the ocean?" you might ask the workers who are repairing the water tower at Jones Beach. They will tell you that both the tower's steel framework and copper roof show extensive corrosion from the salty air. To power future generations of cars, homes, utility plants, and even particle accelerators, unprecedented levels of efficiency will be needed. Such efficiency will require new unconventional alloys and composite materials that can also withstand high temperatures, intense radiation fluxes, high stresses, and other extreme conditions in highly corrosive environments that accelerate the aging and weakening of materials, as salty air weakens steel and copper. During the lecture, Simos will discuss the demands of next-generation energy systems and focus on the extreme conditions that materials used in these systems will perform under. He will also explain Brookhaven ...
2009-06-17
Environmental strategy for energy: hydrogen fuel cell bus for Brazil
Energy Technology Data Exchange (ETDEWEB)
One of the most densely populated urban regions in the world is the Sao Paulo Metropolitan region (SPMR) in the State of Sao Paulo, Brazil. Air pollution is a real problem, mainly caused by vehicle exhaust fumes. The air pollution abatement measures adopted in the SPMR, such as the addition of ethanol to gasoline, the use of cars running on pure alcohol, the restrictions in the circulation of vehicles and the utilization of electronic fuel injection and catalyst have had a positive effect on the environment. The 25,000 buses and approximately 400,000 trucks, all operating on diesel, have not been affected by these measures, and it is believed that SPMR is the ideal location for testing new vehicular pollution reduction technologies. A project to this effect was launched by the Ministry of Mines and Energy in conjunction with a host of other partners, and it involved the operation of a fuel cell bus using hydrogen produced ...
2001-06-01
Efficiency of ozone production by pulsed positive corona discharge in synthetic air
International Nuclear Information System (INIS)
We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh"-"1 and 35-110 ...
2002-06-07
Energy Technology Data Exchange (ETDEWEB)
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted to the evaporative condensers. Capital credit was not given to the system employing ...
1982-07-01
CFD investigation of unstable airflow due to temperature difference via horizontal openings
Energy Technology Data Exchange (ETDEWEB)
Air flow and the buoyancy-driven flow through a building`s horizontal openings was discussed. Horizontal openings occur in staircases, stairwells, ventilation shafts and chimneys. Mass and energy transfer through them have important implications regarding energy saving, thermal comfort, control of contaminants and micro-organisms and spread of fire and smoke. The analysis of the buoyancy-driven flow was attained using computational fluid dynamics (CFD). Use was made of the CFD code FLUENT which integrated the Navier-Stokes equations by a time-dependent, finite volume method. Good agreement was achieved between predicted and experimental measurements of flow rate. Results showed that flow patterns in horizontal openings were transient and unstable. The air exchange through the openings occurred in intermittent pulses. The flow rate through the opening increased with the temperature difference between ...
1995-12-31
[Special cases of vascular injuries by war projectiles].
The author resumes what is actually known about the behaviour of war projectiles in the target (wound ballistics). This is function of their nature, their velocity, their air trajectory. The difference between lesions due to slow moving bullets and these due to projectiles with a high kinetic energy is outlined. The last ones create, through the temporary cavitation effect, lesions at distance from the residual visible tract, particularly in the vascular conduits. The therapeutic conclusions, which derive from those ballistic behaviours, are briefly described in matter of repair of vascular war injuries [Acta chir. belg., 1982, 82, 457-461]. PMID:7148288
Thermodynamic analysis of a hybrid geothermal heat pump system
British Library Electronic Table of Contents (United Kingdom)
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
2011-01-01
International Nuclear Information System (INIS)
The article is an overview on atmospheric pollution in Lebanon. It presents an analysis of sources of pollution in the country and their impacts on local and global environment and describes their control. Air pollution is mainly due to the industrial, electrical and transportation sectors. Pollutants from fuel combustion are analyzed. It is estimated that in 2010, CO_2 emissions will reach 5987250 tons, SO_2 emissions is estimated to be 182950 tons, Nox to 105180 and dusts to 4965 tons. CFC consumption and measures of control according to Montreal protocol are described. Consumption of primary energy, consumption of petroleum products, quantity of petroleum in refineries and production of cement in Lebanon are also presented in tables
2000-02-01
Low Temperature Systems (LTS); LTS (Lage Temperatuur Systemen)
Energy Technology Data Exchange (ETDEWEB)
Several aspects of low temperature systems (LTS) are discussed in five articles. In the first article the role of municipalities in the Netherlands in the implementation of LTS is outlined. In the second article a brief overview is given of a brochure in which 9 projects with LTS are described. In article three the results of a literature study on qualitative aspects (thermal comfort, air quality, energy consumption, safety and cost) of LTS are presented. In the fourth article it is outlined why one should apply LTS, and the fifth article is a reflection of the discussion that took place at the TVVL symposium on sustainable concepts and sustainable installation
1999-04-01
Improvement of the efficiency of a bare solar collector by means of turbulence promoters
Energy Technology Data Exchange (ETDEWEB)
A steady-state mathematical model was developed for a bare collector. Results obtained by previous authors for heat transfer and friction in rectangular ducts with periodic disturbances were employed to evaluate the effect of such disturbances on bare collector efficiency and on its pressure drop. An effective efficiency, which takes into account extra heat obtained and additional mechanical (electric) energy consumption for moving air when heat-transfer augmentation devices are employed, was defined. Simulation results are given for a bare collector, with and without perturbations, showing efficiency and effective efficiency dependence on collector dimensions, solar radiation intensity, disturbance diameter and pitch for collector performance optimization. (author).
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
This work develops and demonstrates a laboratory-scale high temperature natural gas furnace that can operate with/without oxygen enrichment to significantly improve energy efficiency and reduce emissions. The laboratory-scale is 5ft in diameter & 8ft tall. This furnace was constructed and tested. This report demonstrates the efficiency and pollutant prevention capabilities of this test furnace. The project also developed optical detection technology to control the furnace output.
2007-02-16
Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note
Energy Technology Data Exchange (ETDEWEB)
The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.
1986-01-01
Electric vehicle getting up speed soon?; Kommt E-Mobil in Fahrt?
Energy Technology Data Exchange (ETDEWEB)
A novel zinc-air battery might soon enhance the mileage and applications of electric vehicles. The battery named Zoxy battery weighs 80% less than a conventional lead battery, but has an equal amount of energy in store. (orig./CB) [Deutsch] Eine neuartige Zink-Luft-Batterie koennte vor allem dem Elektroauto groessere Reichweiten und neue Einsatzmoeglichkeiten erschliessen. Die sogenannte Zoxy-Batterie ist 80% leichter als eine herkoemmliche Bleibatterie - bei gleichem Energiegehalt. (orig.)
1997-12-31
Analysis of convective losses from cavity solar central receivers
Energy Technology Data Exchange (ETDEWEB)
An analytical model is presented which enables the estimation of convective losses from cavity receivers. Evidence from solar experiments is used to test the hypothesized mechanisms. The analytical results and experimental evidence indicate that the convective loss from cavity receivers is appreciable. The model indicates that the influences of the wind on the convective loss at normal operating conditions are minimal. It also shows that the internal thermal resistance, i.e. the ability to heat the air inside the cavity, are of importance. Buoyancy induced flows are, on the other hand, effective in transferring energy across the aperture. 8 refs.
1981-01-01
A new type active personal dosemeter with a solid state detector
International Nuclear Information System (INIS)
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
1988-04-01
Room air quality. Raumluftqualitaet
Energy Technology Data Exchange (ETDEWEB)
Room air quality and thus thermal comfort for the occupiers in closed spaces depend on several factors: temperature and humidity of the air, temperature of the surrounding surfaces, content of foreign matter of the air, acoustical perceptions, electric fields and ions as well as colours and light. Air humidification, cleaning and ionization largely contributes to improved room air quality. The article goes into problems of too dry and polluted air as well as into measures with which these problems can be solved. (BWI).
1990-12-01
Remote power systems with advanced storage technologies for Alaskan villages
Energy Technology Data Exchange (ETDEWEB)
Remote Alaskan communities pay economic and environmental penalties for electricity, because they must import diesel as their primary fuel for electric power production, paying heavy transportation costs and potentially causing environmental damage with empty drums, leakage, and spills. For these reasons, remote villages offer a viable niche market where sustainable energy systems based on renewable resources and advanced energy storage technologies can compete favorably on purely economic grounds, while providing environmental benefits. These villages can also serve as a robust proving ground for systematic analysis, study, improvement, and optimization of sustainable energy systems with advanced technologies. This paper presents an analytical optimization of a remote power system for a hypothetical Alaskan village. The analysis considers the potential of generating renewable energy (e.g., wind and ...
1997-12-01
An experimental study of H-air counterflow diffusion flames (CFDFs) is reported. Coaxial tubular
1989-01-01
Tachyons revisited - comments on a search for faster-than-light particles
International Nuclear Information System (INIS)
An apparently significant result in an experiment to search for tachyons in the interval of time immediately preceding the arrival of air showers of energy greater than 10"1"5 eV has been reported by Clay and Crouch (Clay, R.W. and Crouch, P.C., 1974, Nature, vol.248,28-30). Several similar experiments have been completed, all of which have yielded null results. The original data of Clay and Crouch have been re-examined and it is shown that an artifact of the apparatus was contributing to the original, apparently significant, result. An upper limit estimate shows that the number of tachyons is less than the number of hadrons of energy greater than 100 GeV in showers of average size N = 6 x 10"5 particles. (author).
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Energy Technology Data Exchange (ETDEWEB)
This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee and liability are ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
This study presents a full cost approach to determine the levelized cost of energy (LCOE) of 14 electricity generation technologies. It encompasses costs incurred at all stages of the fuel cycle, including those that are traditionally omitted from economic evaluations of generation technologies. Incorporating these 'externalities' increases the likelihood of developing the most economical and sustainable power resource from a societal perspective. The following externalities are included in this analysis: damage from air pollution, energy security, transmission and distribution costs, and other environmental impacts. Incorporating externalities has a large impact on the LCOE and the relative attractiveness of electricity generation options. Results indicate that clean and efficient generation technologies are the most attractive when all options are examined using a full cost, levelized approach. (author)
2002-12-01
Emissions trading and green power : profitability for buyers and sellers
Energy Technology Data Exchange (ETDEWEB)
Proposed features of the competitive electricity market in Ontario were reviewed. The speaker predicted that demand for renewable energy in Ontario`s competitive electricity market will be affected by green power, emissions trading, labelling, and renewables portfolio standard. Under current regulations retailers can charge customers a premium for purchasing electricity generated by `green` sources. The existing limits on emissions of sulphur dioxide, nitrogen oxides and carbon dioxides will remain in place, but an emissions cap and trading program for all Ontario-based generation is an option to consider. Ontario`s Market Design Committee (MDC) has recommended the implementation of emissions trading for electricity-related air pollutants for all generators located in Ontario. The complex mechanics of emission trading are explained. The MDC recommendation of the use of standard labels to disclose the mix of energy sources ...
1998-12-31
Efficient, low emissions gas range cooktop
Energy Technology Data Exchange (ETDEWEB)
Disclosed is a gas-fired cooktop for a range which provides high thermal efficiency and low emissions of air pollutants, particularly low levels of NO{sub x}. The cooktop includes a perforated tile burner which radiates infrared energy upward at a high flux rate to rapidly quench burner gas temperatures and inhibit the formation of NO{sub x}. A perforated glass-ceramic jet plate positioned between the burner and a cooking vessel transmits most of the radiant infrared energy from the burner to the vessel and also forms jets of combustion products which are directed against the bottom of the vessel fo convective heating. Thermal efficiencies of up to about 70% and NO{sub x} emissions as low as about 15ppM are achieved by the cooktop.
1990-01-09
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.
2003-07-01
British Library Electronic Table of Contents (United Kingdom)
Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Air quality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag ...
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.
1993-11-01
Technical considerations associated with waste-to-energy systems
Energy Technology Data Exchange (ETDEWEB)
The average American generates four pounds of solid waste per day, yet increasing constraints are being placed on the ability of municipalities to handle waste disposal. Most cities face a scarcity of acceptable landfill sites and conventional incineration and landfill methods have come under strict air, water and soil pollution standards. City administrators are being encouraged to select from a variety of proposed technologies that supplant traditional waste disposal methods, some of which offer the promise of revenues from energy and resource recovery. The problem is to select from available near-term technologies those systems that will fit into a city's long-term solid-waste management program. Broadly, waste-to-energy recovery systems now available to cities may be classified as combustion, pyrolysis, biodegradation, and mechanical front-end systems. It is important to notice that operations used for ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Three agricultural applications in a specially designed greenhouse solar system functioning as a multi-purpose solar air collector for crop production and curing/drying processes are examined. An automated hydroponic crop production system is proposed for the greenhouse solar system. Design criteria of the proposed system and its utilization of solar energy for root-zone warming are presented and discussed. Based upon limited testing of the hydroponic system considered, hydroponic production of greenhouse crops is believed reasonable to complement the year-round use of the greenhouse solar system. The hardware/software design features of a microcomputer-based control system applied in the greenhouse solar barn are presented and discussed. On-line management and utilization of incident solar energy by the microcomputer system are investigated for both the greenhouse and tobacco curing/drying modes of operation. The design ...
1987-01-01
Probabilistic power generation planning with environmental consideration for Lebanon
International Nuclear Information System (INIS)
Full text.This paper describes a software tool for generation expansion planning based on dynamic programming, probabilistic production simulation, and environmental assessment. The aim is to determine the units needed to expand a given system in order to minimize either the cost or the environmental impact or some weighed function of the two. The problem of generation expansion planning is solved in stages using Tunnel Dynamic Programming (TDP) with Heuristic rules to limit the number of options analyzed. The production costing methodology is based on combining a probabilistic generation model known as the capacity outage table (COT) with the load duration curve (LDC) of the system to deduce a risk model from which the expected energy not supplied (EENS) is estimated. The generation model is built recursively using an efficient numerical convolution procedure and is combined at each step with the LDC to calculate the expected energy produced ...
2000-11-23
Energy Technology Data Exchange (ETDEWEB)
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within ...
1997-11-01
British Library Electronic Table of Contents (United Kingdom)
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...
2008-01-01
Emissions from power plants 1987-1996; Emissioner fra kraftvaerkerne 1987-1996
Energy Technology Data Exchange (ETDEWEB)
The document gives statistics on the pollutive emissions from Danish power plants during the period 1987-1996, the main pollutants being sulphur dioxide, nitrogen oxides and carbon dioxide. Data on efficiency levels relative to the production of electricity and heating and on the power plants` contribution to the total emission of CO{sub 2}, NO{sub x}, and SO{sub 2} from energy consumption in Denmark, are presented, and also as corrected for the net import of electricity. Other data on the emission of each of these chemicals by power plants are presented as factual, and corrected in accordance with the net import of electricity, and as factual per consumed and produced energy unit at the power plants. Short notes on related Danish legislation are found in addition to information on sources, methods and definitions used as a basis for the production of this document. Emission from power stations is dependent on their energy ...
1997-08-01
Drying characteristics and nitrogen loss of biogas digestate during drying process
Energy Technology Data Exchange (ETDEWEB)
The cost of transporting biogas digestate can be decreased by reducing its water content. However, the digestate emits volatile compounds during drying. This study investigated the drying behaviour and the change of digestate composition. Drying took place in a hybrid solar/waste-heat dryer that used solar energy as well as waste heat from a combined heat and power unit (CHP) and the exhaust air of a microturbine. The experiment involved the use of 60 t of liquid digestate. Climatic conditions were measured inside and outside the drying hall. Dry matter (DM) and organic dry matter (ODM) were also measured on a daily basis. In addition, the energy consumption of waste and solar heat were recorded and related to the quantity of dried feedstock. The total nitrogen, ammonium, phosphate, potassium oxide, magnesium oxide and calcium oxide in the digestate were subjected to chemical analysis before and after the drying process. ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The Externally-Fired Combined Cycle (EFCC) is an attractive emerging technology for powering high efficiency combined gas and steam turbine cycles with coal or other ash bearing fuels. In the EFCC, the heat input to a gas turbine is supplied indirectly through a ceramic air heater. The air heater, along with an atmospheric coal combustor and ancillary equipment, replaces the conventional gas turbine combustor. A steam generator located downstream from the ceramic air heater and steam turbine cycle, along with an exhaust cleanup system, completes the combined cycle. A key element of the EFCC Development Program, the 25 MMBtu/h heat-input Kennebunk Test Facility (KTF), has recently begun operation. The KTF has been operating with natural gas and will begin operating with coal in early 1995. The US Department of Energy selected an EFCC repowering of the Pennsylvania Electric Company`s Warren Station for ...
1995-06-01
Energy Technology Data Exchange (ETDEWEB)
At the request of the US Department of Housing and Urban Development (HUD), the Pacific Northwest Laboratory estimated the material, labor, and operating costs for ventilation equipment needed for compliance with HUD`s proposed revision to the ventilation standard for manufactured housing. This was intended to bound the financial impacts of the ventilation standard revision. Researchers evaluated five possible prototype ventilation systems that met the proposed ventilation requirements. Of those five, two systems were determined to be the most likely used by housing manufacturers: System 1 combines a fresh air duct with the existing central forced-air system to supply and circulate fresh air to conditioned spaces. System 2 uses a separate exhaust fan to remove air from the manufactured home. The estimated material and labor costs for these two systems range from $200 to $300 per home. Annual operating ...
1993-11-01
Environmental releases for calendar year 1997
Energy Technology Data Exchange (ETDEWEB)
This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Order 5400.1. This report provides supplemental information to the Hanford Site Environmental Report (PNNL-11795). The Hanford Site Environmental Report provides an update on the environmental status of the Hanford Site. The sitewide annual report summarizes the degree of compliance with applicable environmental regulations and informs the public concerning the impact of Hanford Site operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (FDH), and Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data on air emissions, liquid effluents, and hazardous substances released to the environment during calendar ...
1998-08-25
Engineering Development of Coal-Fired High-Performance Power Systems
Energy Technology Data Exchange (ETDEWEB)
A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine ...
2000-12-31
Energy Technology Data Exchange (ETDEWEB)
Experts tend to disagree about the economic effects of air pollution abatement measures. This book, which addresses also non-experts, explains the analytical background on the basis of available data. The authors conclude that there is a wide range of political options for achieving the goal of air pollution abatement. They differentiate between the various levels of discussion and show how misinterpretations of scientific results come about, thus making an important contribution to a discussion that is based on facts rather than emotions. [German] Die Einschaetzungen zur wirtschaftlichen Bewertung von Klimaschutzmassnahmen, insbesondere zur Steigerung der Energieeffizienz, sind sehr widerspruechlich. Dieses Buch erlaeutert anhand von Zahlenmaterial die analytischen Hintergruende und ist auch fuer Nicht-Oekonomen verstaendlich geschrieben. Die Autoren kommen zu dem Schluss, dass in vielen Bereichen rentable Energiesparpotentiale nicht erkannt ...
2000-07-01
Application of the Center for Air Toxic Metals (CATM) database
Energy Technology Data Exchange (ETDEWEB)
A relational database capable of storing and manipulating the large volumes of data on air toxic metals has been developed for the Center for Air Toxic Metals at the Energy and Environmental Research Center (EERC) of the University of North Dakota. The database provides information to researchers, managers, and operations personnel to aid in their decision making and long-term planning of issues related to air toxic metals. A personal computer-based graphical user interface is used to access the data located on a UNIX workstation at the EERC. With security codes and software issued by the EERC and an Internet service provider in place, the database can be accessed externally through the Internet. Currently the database contains over 3000 analytical measurements from nine full-scale systems and several bench-scale operations. Data are available on gas, solid, and liquid stream samples as well as relevant ...
1996-12-31
Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatre
Energy Technology Data Exchange (ETDEWEB)
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of ...
2008-07-01
A zinc-air battery and flywheel zero emission vehicle
Energy Technology Data Exchange (ETDEWEB)
In response to the 1990 Clean Air Act, the California Air Resources Board (CARB) developed a compliance plan known as the Low Emission Vehicle Program. An integral part of that program was a sales mandate to the top seven automobile manufacturers requiring the percentage of Zero Emission Vehicles (ZEVs) sold in California to be 2% in 1998, 5% in 2001 and 10% by 2003. Currently available ZEV technology will probably not meet customer demand for range and moderate cost. A potential option to meet the CARB mandate is to use two Lawrence Livermore National Laboratory (LLNL) technologies, namely, zinc-air refuelable batteries (ZARBs) and electromechanical batteries (EMBs, i. e., flywheels) to develop a ZEV with a 384 kilometer (240 mile) urban range. This vehicle uses a 40 kW, 70 kWh ZARB for energy storage combined with a 102 kW, 0.5 kWh EMB for power peaking. These technologies are sufficiently near-term ...
1995-10-03
A novel zinc-air battery for electric vehicles
Energy Technology Data Exchange (ETDEWEB)
A new type of zinc electrode is matched with new bifunctional air electrodes to produce a zinc-air battery of a novel design. The zinc electrode is a flow-thru type made from copper foam-metal. The air electrode uses corrosion resistant carbon black as a high area support for a highly dispersed spinel oxide electrocatalyst. The battery design employs flowing electrolyte, 12 M KOH saturated or supersaturated with zincate. Single cells as large as 200 cm{sup 2} (1/5 EV design scale) having a capacity of 20 AH have been tested with C/4--C/16 constant current cycling. More extensive and realistic life cycle testing was done with 2 Ah cells, including the Simplified Federal Urban Driving Schedule (SFUDS) cycle. This testing has confirmed that these cells can provide the necessary transient power response required for urban EV applications. The cells achieved an average of 72 SFUDS repetitions (7.2 hrs) per discharge cycle, more ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
This proceedings volume comprises 17 papers on the following subjects: Methane hydrates, compounds of gas and water; Compressed air stroage gas turbine power plants / Scheduled application for load levelling between varying wind power production and power demand; Modern pumped storage power stations in the GW range - the PSW Goldisthal example; Lead batteries - new developments and future applications; Alkaline battery systems for hybrid electric road vehicles; Lighium systems and their applications; Zinc/air cells; Hydrogen storage - metal hydride storage, compressed gas storage, LNG storage; Carbon nanofibres for hydrogen storage; Double-layer condensers - technology, cost, perslpectives; Supercondensers in motor vehicles; Superconducting magnetic energy stores; Flywheel storage - status report; Decentralized energy storage in the European integrated supply grid - the EU project DISPOWER; ...
2002-07-01
Principles of room air flow; Grundlagen der Raumluftstroemung
Energy Technology Data Exchange (ETDEWEB)
The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and air quality, evaluation of the ventilation. figs., tabs., refs.
1994-12-31
Ultra fine grinding of low-rank coal. Progress report, April-June 1986
Energy Technology Data Exchange (ETDEWEB)
The lignite used for Phase I of the project was a Texas lignite from the Martin Lake mine obtained from the stockpile for the Martin Lake Power Plant of the Texas Utilities Generating Company. The power requirements for the fluid-energy mill were determined from the measured steam (or air) temperatures, pressures and pressure drops and the lignite flow rate. The instrument locations for the tests are shown on Figure 1. All of the instruments were connected to a microcomputer via an analog input interface board. Data were recorded on disks periodically throughout the tests. Appropriate calibration procedures were followed to assure that reliable data were being obtained. The combined grinding/drying tests were conducted in Vicksbuth, MS at Ergon, Inc.'s fluid-energy-mill facility. both steam and air were used as grinding fluids. With steam, tests were used as grinding fluids. With steam, tests ...
1986-07-01
Energy Technology Data Exchange (ETDEWEB)
As part of a five-year-lasting open-top-chamber experiment at the `Edelmannshof` site (Welzheimer Wald) we analyzed Norway spruce trees (Picea abies (L.) Karst.) with regard to carbohydrate and energy (ATP/ADP ratio) metabolism. End products, intermediates, and a regulator of carbon allocation (starch, sucrose, hexoses, fructose-2,6-bisphosphate) as well as enzyme activities involved in sucrose metabolism (sucrose-P synthase, sucrose synthase, acid invertase) were determined in needle and trunk samples of the different treatments (charcoal-filtered, unfiltered, ambient air). Changes of these parameters were documented annually and with regard to needle development (up to 2 years after bud break), and diurnally during an ozone period in midsummer. Samples from trees grown in an unfiltered atmosphere showed relatively high sucrose and hexose contents of the needles. The capacities of sucrose-P synthase (increased; sucrose synthesis) and acid ...
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
This study examines various aspects of natural radioactive materials in the atmosphere over Perth in order to characterise the behaviour of these radionuclides. Data for this study was provided by the surface air sampling program (SASP) of the U.S. Department of Energy, which focuses on the lowest 2 metre layer of air; sampling being at 1.6 metres above the surface. The study particularly aimed to interpret correlation between existing radionuclide concentration data and meteorological data; which has been achieved in a qualitative sense. A general conclusion drawn form the observed results is that long-term averages of radionuclide concentrations have the highest correlation with climatic data; correlations between sample readings and contemporaneous weather data have the lowest correlation coefficients. Limitations in both the radionuclide and meteorological data were realised early in the project. The focus of the ...
1995-12-31
Alternative standards and instruments for air pollution control in Poland
Energy Technology Data Exchange (ETDEWEB)
Like other Central European countries, Poland faces the twin challenges of improving environmental quality while also fostering sustainable economic development. In this study we examine the costs of different standards for air pollution control, and the cost savings from using incentive-based policy instruments in lieu of more rigid command-and-control policies. The comparisons are based on the results of a simulation model of energy use and air pollution control for the Polish economy over 1990-2015. The model simulates least-cost energy supply decisions under different environmental policy assumptions, the corresponding emissions, and the cost of achieving the specified policy objectives. The model results suggest that incentive-based policies will have efficiency gains over command policies that are at least worthy of consideration and may be quite substantial. The size of the gains in practice ...
1994-10-01
Optimal capacity of the battery energy storage system in a power system
Energy Technology Data Exchange (ETDEWEB)
Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and ...
1993-12-01
Materials for power sources to meet military requirements
Energy Technology Data Exchange (ETDEWEB)
Power source requirements for the military were presented to provide guidelines for research and development planning. Power sources that contain a high amount of energy and are small, light and durable are a common request from military users. Safety, reliability and low temperature performance are also important factors in the selection of power sources, as are cost and energy efficiency. Issues concerning advanced batteries were reviewed with reference to high energy density cathode materials. Various thermoelectric and renewable energy materials were discussed, with reference to recovery and conversion of waste heat. It was suggested that photovoltaic devices could help revolutionize military logistics by modifying energy re-supply requirements. Solid Oxide Fuel Cells (SOFC) were considered in relation to the high price of the ceramic materials required for operation. It was ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
To realise the Dutch objectives of energy saving and emission reductions in the built environment, the use of 'Low Valued Energy' will be necessary in the future. Low Valued Energy is available from residual, ambient heat and renewable sources. Using Low Valued Energy for space heating in commercial and residential buildings requires adjusting the design of the installations, i.e. lowering the design supply temperature of the heating system from 90C to 55C or less. Appropriate heat distribution systems, e.g. floor or wall heating and radiators, have a life cycle of 40 to 50 years. The application (on a large scale in buildings), however, requires an enormous change in the installation and building branch. To enable the application of low temperature sources in the future, the building and installation designs should be based on low temperature distribution systems. Being aware of this ...
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents efforts to date and prospective goals towards development of a modelling and analysis framework which is comprehensive enough to address the global climate crisis, and detailed enough to provide policymakers with concrete targets and achievable outcomes. In terms of energy efficiency policy, this requires coverage of the entire world, with emphasis on countries and regions with large and/or rapidly growing energy-related emissions, and analysis at the 'technology' level-building end use, transport mode or industrial process. These elements have not been fully addressed by existing modelling efforts, which usually take either a top-down approach, or concentrate on a few fully industrialized countries where energy demand is well-understood. Inclusion of details such as appliance ownership rates, use patterns and efficiency levels throughout the world allows for a deeper understanding of ...
2009-05-29
Co-combustion of recycled waste materials with peat and coal in a 15 kw fluidized bed reactor
Energy Technology Data Exchange (ETDEWEB)
Co-combustion tests for recycled fuels and peat were made at a 15 kW fluidized bed reactor at VTT Energy in Jyvaeskylae. Peat was used as reference fuel. 25 tests in total were performed during 1994 - 1996. A part of the peat energy was substituted by coal in five tests, in order to change the sulphur/chlorine ratio of the fuel mixture. Fuel mixtures (25% recycled fuel and 75% peat, at energy ratio) were pelletized in order to get homogeneous fuel mixtures. The tests in the year 1994 were air staging experiments (with and without tertiary air). All test were performed with air staging in the years 1995 and 1996. The aim of the research was to determine whether the co-combustion of waste materials will cause additional emission problems, as compared to combustible emissions from conventional air-staged fluidized bed combustion. Further, the ...
1998-12-31
Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector
Energy Technology Data Exchange (ETDEWEB)
The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ...
2006-07-01
International Nuclear Information System (INIS)
Since the 1970s, Danish electricity supply has been dependent on imported coal. This has lead to greater reliability of supply, as could be seen during the Gulf War when Danish electricity prices remained stable in contrast to conditions in other countries. The disadvantage is the air pollution caused by coal combustion. This is regulated, it is stated, by several international laws and agreements, and these are named here. The nature of this form of pollution is explained in relation to actual Danish power plants and their efforts to reduce emissions of sulphur dioxide and nitrogen oxides. Carbon dioxide, which is a greenhouse gas, is also emitted. Danish environmental policy concentrates on these problems. The efforts of the electric power companies to reduce air pollution are detailed, both nationally and internationally, and their positive consequences are described. Desulphurization and denitrification costs are claimed to be 4.6 Danish ...
1990-10-22
Energy Technology Data Exchange (ETDEWEB)
World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating ...
2010-05-15
Energy Technology Data Exchange (ETDEWEB)
Worker exposures to N-nitroso compounds were evaluated at B.F. Goodrich Company, Woodburn, Indiana on December 12, 1979. Personal and area air samples were collected and analyzed by gas-chromatography and thermal-energy-analysis methods. All of the samples contained N-nitrosomorpholine (NMOR) and five samples also contained N-nitrosodimethylamine (NDMA). The amount of NMOR ranged from 0.85 to 3.7 micrograms per cubic meter (micrograms/cu m) for area air samples and 0.63 to 1.8 micrograms/cu m for personal samples. NDMA concentrations ranged from undetectable to 1.8 microgram/cu m for area samples and undetectable to 0.09 micrograms/cu m for personal samples. The authors note that no exposure standards exist for NDMA or NMOR but both are listed as potential human carcinogens. They suggest that the B.F. Goodrich Company characterize nitrosamine exposures at this facility.
1980-02-28
Energy Technology Data Exchange (ETDEWEB)
A numerical model was developed to simulate the combined effects of heat transfer, magnetite oxidation, and NO{sub x} formation in a grate-kiln furnace for taconite pellet induration. Heat transfer from the flame in the kiln was described by the net radiation method. The shrinking core model was used to account for magnetite oxidation on the grate. A novel approach to oxidation of tumbling pellets in a kiln was derived. The Zeldovich mechanism was used to predict thermal NO generation. Temperature fluctuations in the gas streams were estimated with a clipped Gaussian probability density function. The thermal energy balances and mass balances resulted in coupled systems of first-order differential equations, which were solved numerically. The model is capable of predicting NO production and magnetite oxidation in agreement with observation of plant performance. Although the design of the grate-kiln system is for efficient heat and mass transfer, it may not be the ...
1996-12-31
Electrochemical power generation apparatus and methods
Energy Technology Data Exchange (ETDEWEB)
Apparatus and methods are described for generating heat and electricity from the consumption of a variety of aluminum products. The method consists of (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The latter may be used in a slurry type ...
1981-03-03
Electrochemical power generation
Energy Technology Data Exchange (ETDEWEB)
Apparatus and methods for generating heat and electricity from the consumption of a variety of aluminum products comprise: (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The latter may be used in a slurry type zinc/air ...
1983-01-18
Energy Technology Data Exchange (ETDEWEB)
A team at the Paul Scherrer Institute (PSI) recently achieved a breakthrough in the development of an environment-friendly and rechargeable battery with novel electrodes. The energy storage density of a rechargeable 12 V/20 Ah zinc/air battery could be increased to 100 watt hours per kilogramme - three times as much as conventional lead accumulators. 20-Ah cells could be charged and discharged 55 times in 1000 hours without any loss of capacity worth mentioning. This is a remarkable cycle stability. (orig.) [German] Einem Team des Paul Scherrer Instituts (PSI) ist kuerzlich bei der Entwicklung einer umweltfreundlichen und wiederaufladbaren Batterie mit neuartigen Elektroden der Durchbruch gelungen. Dabei konnte die Energiespeicherdichte einer wiederaufladbaren 12 V/20 Ah-Zink-Luft-Batterie auf 100 Wattstunden pro Kilogramm gesteigert werden - dreimal soviel wie bei konventionellen Bleiakkumulatoren. 20-Ah-Zellen konnten in 1000 Stunden ohne ...
1999-10-01
International Nuclear Information System (INIS)
A high-performance power system (HIPPS) is being developed. This system is a coal-fired, combined-cycle plant that will have an efficiency of at least 47 percent, based on the higher heating value of the fuel. The original emissions goal of the project was for NOx and SOx to each be below 0.15 lb/MMBtu. In the Phase 2 RFP this emissions goal was reduced to 0.06 lb/MMBtu. The ultimate goal of HIPPS is to have an all-coal-fueled system, but initial versions of the system are allowed up to 35 percent heat input from natural gas. Foster Wheeler Development Corporation is currently leading a team effort with AlliedSignal, Bechtel, Foster Wheeler Energy Corporation, Research-Cottrell, TRW and Westinghouse. Previous work on the project was also done by General Electric. The HIPPS plant will use a high-Temperature Advanced Furnace (HITAF) to achieve combined-cycle operation with coal as the primary fuel. The HITAF is an atmospheric-pressure, pulverized-fuel-fired ...
1995-07-12
Conversion of energy and power sources to gas fuel: effects on air quality
International Nuclear Information System (INIS)
The consequences of converting a facility from brown coal fuel to gas fuel were analyzed by model simulation. Treated were a district heating plant with an output of 700 TJ/yr and minor local heating sources (stoves) at a density of 1 family house per 100 m"2. Emissions of particulate matter, sulfur dioxide, nitrogen oxides, carbon monoxide, and hydrocarbons before and after the conversion are given for the two types of source. Conversion of a major air pollution source to gas fuel would result in a reduction of the contribution of sulfur dioxide emissions of the order of 10"-"4, of particulate matter and carbon monoxide of the order of 10"-"3, and of hydrocarbons of the order of 10"-"2. The decrease will be lowest for nitrogen oxides, viz. about 40%. Analogous data for local heating sources in towns would be 10"-"5 for sulfur dioxide, 10"-"4 for particulate matter, 10"-"3 for carbon monoxide and hydrocarbons, and roughly one order of magnitude for nitrogen oxides. ...
1994-02-01
Chemical Looping Combustion System-Fuel Reactor Modeling
Chemical looping combustion (CLC) is a process in which an oxygen carrier is used for fuel combustion instead of air or pure oxygen as shown in the figure below. The combustion is split into air and fuel reactors where the oxidation of the oxygen carrier and the reduction of the oxidized metal occur respectively. The CLC system provides a sequestration-ready CO2 stream with no additional energy required for separation. This major advantage places combustion looping at the leading edge of a possible shift in strict control of CO2 emissions from power plants. Research in this novel technology has been focused in three distinct areas: techno-economic evaluations, integration of the system into power plant concepts, and experimental development of oxygen carrier metals such as Fe, Ni, Mn, Cu, and Ca. Our recent thorough literature review shows that multiphase fluid dynamics modeling for CLC is not available in the ...
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
An investigation was given on the relationship between methanol adsorbing behavior of reformed coal surface and oxygen containing functional groups in coal. Akabira bituminous coal was air-oxidized or Yallourn brown coal was decarbonated in oil as a reformation treatment. Both of the treated and untreated coals showed an adsorption heat curve of the Langmuir type. The Akabira coal had its oxygen content and the adsorption heat increased as a result of the air oxidizing reformation treatment. The Yallourn coal had its oxygen content and adsorption heat decreased as a result decarbonation reformation treatment. Oxygen containing functional groups act as strong adsorption sites for methanol, and the maximum adsorption amount depends on oxygen content in the coals. Since the coal surface is non-uniform in terms of energy, methanol is adsorbed first into sites with higher molar adsorption heat, and then into lower sites ...
1996-10-28
International Nuclear Information System (INIS)
The DOE is conducting a comprehensive technical analysis of a flexible-fuel transportation system in the United States -- that is, a system that could easily switch between petroleum and another fuel, depending on price and availability. The DOE Alternative Fuels Assessment is aimed directly at questions of energy security and fuel availability, but covers a wide range of issues. This report examines environmental, health, and safety concerns associated with a switch to alternative- and flexible-fuel vehicles. Three potential alternatives to oil-based fuels in the transportation sector are considered: methanol, compressed natural gas (CNG), and electricity. The objective is to describe and discuss qualitatively potential environmental, health, and safety issues that would accompany widespread use of these three fuels. This report presents the results of exhaustive literature reviews; discussions with specialists in the vehicular and fuel-production industries and ...
2004-06-07
A novel gas turbine cycle with hydrogen-fueled chemical-looping combustion
Energy Technology Data Exchange (ETDEWEB)
In this paper we have proposed a novel gas turbine cycle with hydrogen-fueled chemical-looping combustion, and the system study on two hydrogen-fueled power plants, the new gas turbine cycle and an advanced gas turbine cycle with H{sub 2}/O{sub 2} combustion, has been investigated with the aid of exergy principle (EUD methodology). The hydrogen fueled chemical-looping combustion in the new gas turbine cycle consists of two successive reactions: hydrogen fuel is reacted with metal oxide (reduction of metal oxide), and then instead of air or pure oxygen, the reduced metal is successively oxidized by the saturated air. As a result, the new hydrogen-fueled gas turbine cycle has a breakthrough performance, with at least about 12 percentage-point higher efficiency compared to the gas turbine cycle with H{sub 2}/O{sub 2} combustion, and will be environmentally superior due to complete elimination of NO{sub x} formation. The promising results obtained ...
2000-12-01
Surface analysis by Fourier-transform infrared (FTIR) spectroscopy
Energy Technology Data Exchange (ETDEWEB)
A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.
1981-08-12
Separation of rubidium from irradiated aluminum-encapsulated uranium
International Nuclear Information System (INIS)
A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.
1993-05-01
Separation of rubidium from irradiated aluminum-encapsulated uranium
Energy Technology Data Exchange (ETDEWEB)
A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.
1982-01-01
Pulsed laser deposition of titanium-carbonitride thin films
Energy Technology Data Exchange (ETDEWEB)
The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).
1997-05-15
Observation of dislocation-mediated layer-by-layer interface growth
Energy Technology Data Exchange (ETDEWEB)
The growth of thin Pd[sub 2]Si films on Si(111) surfaces is studied using [ital in] [ital situ] transmission electron microscope under ultrahigh vacuum conditions. No immediate reaction of deposited Pd with Si is observed at room temperature. At [similar to]200 [degree]C, uniform Pd[sub 2]Si films can be formed. The thin Pd[sub 2]Si films are found to grow into strained islands at elevated temperatures. Interfacial misfit dislocations associated with interfacial steps propagate across the strained islands, causing the islands to grow layer-by-layer at the interface. The strain fields associated with the misfit dislocations are believed to be responsible for this behavior.
1994-07-11
Mesodynamics in the SARS nucleocapsid measured by NMR field cycling
Energy Technology Data Exchange (ETDEWEB)
Protein motions on all timescales faster than molecular tumbling are encoded in the spectral density. The dissection of complex protein dynamics is typically performed using relaxation rates determined at high and ultra-high field. Here we expand this range of the spectral density to low fields through field cycling using the nucleocapsid protein of the SARS coronavirus as a model system. The field-cycling approach enables site-specific measurements of R{sub 1} at low fields with the sensitivity and resolution of a high-field magnet. These data, together with high-field relaxation and heteronuclear NOE, provide evidence for correlated rigid-body motions of the entire {beta}-hairpin, and corresponding motions of adjacent loops with a time constant of 0.8 ns (mesodynamics). MD simulations substantiate these findings and provide direct verification of the time scale and collective nature of these motions.
2009-09-15
High-Voltage Transmission Lines: The Ongoing Search for Biological Effects.
Energy Technology Data Exchange (ETDEWEB)
During the early 1970s, controversy developed over the possible biological effects of electric fields from new 500-kilovolt and 765-kilovolt transmission lines. This, along with growing interest in advancing transmission voltage into the ultrahigh-voltage range (1000 kilovolts and above), led to the initiation of numerous research projects. Several reviews of this research by scientists in the US and other countries indicate that transmission lines have not been proven to be a health hazard to people or animals. The issue remains controversial, however, because research has confirmed some subtle effects of electric fields, and because it is an inseparable part of the public opposition that often accompanies the siting of high-voltage transmission lines. In addition, there is renewed interest in magnetic fields, including a possible association between such fields and human cancers. 2 figures, 2 tables.
1984-12-20
Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses
International Nuclear Information System (INIS)
We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)
International Nuclear Information System (INIS)
A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.
1999-03-01
Guide to Combined Heat and Power Systems for Boiler Owners and Operators
Energy Technology Data Exchange (ETDEWEB)
Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional ...
2004-08-19
Energy Technology Data Exchange (ETDEWEB)
Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in ...
1993-10-01
Report on the International Peer Review of RAINS-ASIA
Energy Technology Data Exchange (ETDEWEB)
Many Asian countries have experienced rapid economic growth during recent years and this trend is expected to continue. The economic growth is accompanied by increasing energy demand, with coal as the dominant energy source. For the first time a model has been specifically developed and applied for integrated assessment of future SO{sub 2} emissions in Asia. The report deals with the RAINS-ASIA model developed in Norway offering an opportunity to assess sulphur deposition and ecosystem protection levels resulting from different energy pathways and different emission control strategies. The cost of various control strategies are also provided. During the project an impressive database has been collected for the region (23 countries, 94 subregions and 355 large point sources). This was made possible through dedicated work by the project team, in close collaboration with scientific and technical institutions in several Asian ...
1995-10-01
International Nuclear Information System (INIS)
A hydrogen combustion and exhaust emissions in a supercharged gas engine ignited with micro pilot diesel fuel was discussed in this presentation. A schematic diagram of the experimental study was first presented. The single cylinder, water-cooled, supercharged test engine was illustrated. Results were presented for the following: fuel energy and energy share (hydrogen and diesel fuel); pressure history and rate of heat release; engine performance and exhaust emissions; effect of nitrogen dilution on heat value per cycle; effect of N_2 dilution on pressure history and rate of heat release; and engine performance and exhaust emissions. This presentation demonstrated that smooth and knock-free engine operation results from the use of hydrogen in a supercharged dual-fuel engine for leaner fuel-air equivalence ratios maintaining high thermal efficiency. It was possible to attain mor3 than 90 per cent ...
2009-09-20
Geothermal Heat Pump research and development studies at Sandia National Laboratories
Energy Technology Data Exchange (ETDEWEB)
The Geothermal Heat Pump (GHP) concept was originally developed in the 1940`s. Recently, because of increasing energy costs, utility interest, and the development of simple and durable ground source heat exchangers, GHP`s have gained international attention as a proven means of energy conservation and electrical peak power demand reduction. GHP systems require installation of a buried heat exchanger to utilize the nearly constant ground temperature making them more efficient than conventional air source heat pumps. However, the high installation cost for both residential and commercial applications is a major obstacle to their market penetration. Sandia National Laboratories (SNL) through its sponsors, the Department of Energy (DOE), and the Department of Defense (DOD), has embarked on a research program to find ways to reduce GHP installation costs and improve performance, thereby increasing their ...
1994-08-01
Energy Technology Data Exchange (ETDEWEB)
This summary denotes the progress made by the Exploratory Technology Research (ETR) Program for Electrochemical Energy Storage during calendar year 1992. The primary objective of the ETR Program, which is sponsored by the US Department of Energy (DOE) and managed by Lawrence Berkeley Laboratory (LBL), is to identify electrochemical technologies that can satisfy stringent performance, durability and economic requirements for electric vehicles (EVs). The ultimate goal is to transfer the most-promising electrochemical technologies to the private sector or to another DOE program (e.g., SNL`s Electric Vehicle Advanced Battery Systems Development Program, EVABS) for further development and scale-up. Besides LBL, which has overall responsibility for the ETR Program, LANL and BNL have participated in the ETR Program by providing key research support in several of the program elements. Program consists of three major elements: Exploratory Research; ...
1993-10-01
Determination of pressure distribution in an aerated bed in a controlled pilot-scale compost reactor
Energy Technology Data Exchange (ETDEWEB)
This study investigated the effectiveness of dealing with biological waste by composting. In particular, it examined the feasibility of recovering excess thermal energy produced in the process of composting biological waste in terms of mass and energy transport parameters required in the aerated compost bed. An experiment was performed in which a 100 dm{sup 3} adiabatic, leak-tight reactor equipped with a controlled aeration system was constructed to study the temperature and pressure distribution in the bed. Sensors were used to determine the amount and humidity of emitted gases under variable external physical conditions. The perforated bottom of the reactor allowed for bed aeration. As such, the humidity and heat were transported upwards, forced by the air pumped in and by natural convection. In terms of pressure distribution inside the composted and aerated bed, the study results showed that there were considerable ...
2010-07-01
An overview of PETC`s gas-to-liquids technology R&D Program
Energy Technology Data Exchange (ETDEWEB)
The overall goal of the Gas-to-Liquids Program at the U.S. Department of Energy`s Pittsburgh Energy Technology Center (PETC) is to develop technologies for the production of hydrocarbon fuels and premium chemicals from light alkane gases. PETC`s current Gas-to-Liquids Program comprises the development of four primary advanced conversion technologies, namely, partial oxidation, oxidative coupling, oxyhydrochlorination, and novel conversion processes. Based on the current state of development, it can be concluded that, in the near future, one or more of these technologies will reach proof-of-concept demonstration. Oxyhydrochlorination is the most advanced direct conversion technology, and the synthesis of lower cost methyl chloride from natural gas would impact several commercial technologies that utilize methyl chloride as an intermediate to high value products. Technology development for the partial oxidation of methane to synthesis gas using ...
1995-04-01
British Library Electronic Table of Contents (United Kingdom)
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Alter both oil crisis, of 1973 and 1979, a bad effect of the elevated costs and continuously increment of the oil prices was noted, for this reason, the interest for renewable energies sources widely available in developing countries was increased. All over the world, governments have formulated main objectives for energies savings and search for friendly technologies, taking into account the effects related with the environment. The imminent scarcity of fossil fuels has made humanity the rational use of primary energies, as a result of these; new plants with improved technology have been conceived taking into account energy savings and efficiency improvement. In this context, biomass gasification technologies are important, since they consist in techniques of parallel production of electricity and heat from just one fuel. This work consists in the development of a gasifier down draft of 100 kW for an ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
A zinc-air battery using zinc regeneration electrolysis with propanol oxidation as a counter electrode reaction is reported in this paper. It possesses functions of both zincate reduction and electrochemical preparation, showing the potential for increasing the electronic energy utilization. Charge/discharge tests and scanning electron microscopy (SEM) micrographs reveal that when a nickel sheet plated with the high-H{sub 2}-overpotential metal, cadmium, was used as the negative substrate electrode, the dendritic formation and hydrogen evolution are suppressed effectively, and granular zinc deposits become larger but relatively dense with the increase of charge time. The performance of batteries is favorable even if the charge time is as long as 5 h at the current density of 20 mA cm{sup -2}. Better discharge performance is achieved using a 'cavity-opening' configuration for the discharge cell rather than a ...
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
The Deutsche Post AG is a transport company that with approximately 55,000 vehicles owns one of the biggest fleets in Europe. Being aware of its responsibility in the field of environmental policy it is looking for an alternative solution of an environmentally friendly vehicle drive system that also takes into account economic efficiency. Extensive investigations have led to a new energy storage based on the zinc-air energy system that has been developed and manufactured by the Israeli Company Electric Fuel Ltd. First tests showed an extraordinarily high capacity potential, drive values and ranges, which had been considered as impossible until that point of time. After these tests the Deutsche Post AG decided together with other well-known partners at home and abroad to carry out a territorial test with the zinc-air energy system in order to obtain insight into the day-to-day ...
1997-07-01
Use plan for demonstration radioactive-waste incinerator
Energy Technology Data Exchange (ETDEWEB)
The University of Maryland at Baltimore was awarded a grant from the Department of Energy to test a specially modified incinerator to burn biomedical radioactive waste. In preparation for the incinerator, the Radiation Safety Office devised a comprehensive plan for its safe and effective use. The incinerator plan includes a discussion of regulations regarding on-site incineration of radioactive waste, plans for optimum use in burning four principal waste forms, controlled air incineration technology, and standard health physics safety practices; a use plan, including waste categorization and segregation, processing, and ash disposition; safety procedures, including personnel and area monitoring; and methods to evaluate the incinerator's effectiveness by estimating its volume reduction factors, mass and activity balances, and by determining the cost effectiveness of incineration versus commercial shallow land burial.
1982-04-01
Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems
Energy Technology Data Exchange (ETDEWEB)
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
2006-03-01
British Library Electronic Table of Contents (United Kingdom)
This paper presents a two-stage solar multi-effect humidification dehumidification desalination process plotted from pinch analysis. The sketch of two-stage solar multi-effect humidification dehumidification desalination process is given. The solar vacuated tube collector is employed in the desalination system, multi-effect humidification dehumidification desalination (HDD) process are plotted two different temperature range according to pinch technology. The higher temperature range is from 60 to 80?C, and the lower is from 30 to 60?C. The mass flow rates of dry air in the two stage desalination units are different. The pinch analysis chart is given. According to the pinch chart, the energy recover rate could get higher according to working temperature range. The research proves that the ...
2008-01-01
Those nuclear wastes nobody knows what to do with; Ces dechets nucleaires dont on ne sait que faire
Energy Technology Data Exchange (ETDEWEB)
The important use of nuclear energy in Europe, and in particular in France, has a beneficial impact on the air quality but raises important problems of radioactive waste management. The technical problems encountered by the French government with the dismantling of Superphenix reactor are a good example. Moreover, despite its reassuring talks, the electronuclear industry lobby, particularly powerful, has never been able to propose any satisfactory solution for the elimination of radioactive wastes. This article makes a criticism of the lack of visibility and democratic debate in France about the sensible subject of nuclear waste management. A comparison with the situation in other countries is made. (J.S.)
1998-01-01
The impacts and costs of global warming. A review
Energy Technology Data Exchange (ETDEWEB)
There is now a scientific consensus that current rates of accumulation of greenhouses gases in the atmosphere will result in significant global warming and climate change. These changes are likely to have important impacts on a wide range of human activities and the natural environment. There has now been a considerable weight of literature published on the impacts of global warming, much of it very recent. This report seeks to summarise the important results, to analyse the uncertainties and to make a preliminary analysis of the feasibility of monetarising these environmental costs. The impacts of global warming are divided into ten major categories: agriculture, forests and forestry, terrestrial ecosystems and biodiversity, hydrology and water resources, sea level rise and coastal zones, energy, infrastructure/transport/industry, human health and air quality, oceans, and cryospheric impacts. The results of major summary reports are analysed, ...
1991-09-01
International Nuclear Information System (INIS)
A stratigraphic and geochemical study of alpine soils, which formed in later Pleistocene (late glacial) and Neoglacial deposits in the Wind River Mountains of western Wyoming, indicates that these soils are affected by air-fall in flux of inorganic pollutants. Arsenic, bromine and antimony appear to have been deposited in surface soils by incorporation of aeolian materials which were presumably transported by winds from industrial sources, including coal-burning operations. As vanadium was not found in surface soils at concentrations above site-specific background levels, oil-fired energy generating stations were not found to be significant sources of surface soil pollution in the region. Acid-rain effects were not observed in the soils. (author) 32 refs.; 2 figs.; 3 tabs.
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
This report is submitted to Congress by the Secretary of the Air Force, the Secretary of the Navy, and the Secretary of the Interior pursuant to Section 6 of the Military Lands Withdrawal Act of 1986. It contains an analysis and evaluation of the effects on public health and safety resulting from DOD and Department of Energy (DOE) military and defense-related uses on withdrawn public lands in the State of Nevada and in airspace overlying the State. This report describes the cumulative impacts of those activities on public and private property in Nevada and on plants, fish and wildlife, cultural, historic, scientific, recreational, wilderness and other resources of the public lands of Nevada. An analysis and evaluation of possible measures to mitigate the cumulative effects of the withdrawal of lands and the use of airspace in Nevada for defense-related purposes was conducted, and those considered practical are listed.
1991-09-23
Radiation hazard control report
Energy Technology Data Exchange (ETDEWEB)
The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.
1982-12-01
Process for the recirculation of nitrogen oxides
Energy Technology Data Exchange (ETDEWEB)
The invention is regeneration and recirculation of nitrogen oxides in the exhaust gas of a nitric acid plant without using any material current and heat energy other than that generated in the process of producing nitric acid. Nitrogen oxide is recovered by at least two adsorbers each containing an acid resistant zeolite molecular sieve and operating in an alternate heat cycle; adsorption occurring at 20-40 degrees C and regeneration at 300-350 degrees C. The hot gas exiting from the oxidation U used in the production of nitric acid is used to regenerate the adsorbers and the nitrogen oxides set free during the said regeneration are introduced into the main feed stream of the nitric acid plant. In the final stage of the regeneration the adsorbers are cooled by rinsing them with exhaust gas or air at a temperature of 20-40 degrees C.
1983-01-04
On the suitability of alternate fuels for dual fuel engine operation
Energy Technology Data Exchange (ETDEWEB)
A compression ignition engine was operated on dual fuel principle inducting two commercial fuels and four pure hydrocarbon fuels in turn through intake manifold along with air and injecting diesel fuel to initiate the combustion in the conventional manner. The engine was operated at different loads and at each load the quantity of inducted fuel was increased gradually till knocking set in. The engine performance and exhaust pollutant emissions were recorded at different operating conditions. It was observed that the extent of induction and the effect on the performance depend on the properties of the inducted fuel such as volatility, self ignition temperature and oxidation characteristics. The energy release during the cycle was also observed to shift depending on the properties of inducted fuel. With the dual fuel operation, the thermal efficiency at part loads was observed to be less compared to neat diesel operation. The thermal efficiency ...
1980-12-01
Near term and future alternative clean vehicle technologies
Energy Technology Data Exchange (ETDEWEB)
Availability of a natural gas-powered van that meets California`s ultra low emission vehicle requirements and has a 300-km range was reported. A similar van with an electric system giving a range of 240 km was also within sight. Regarding the limitations of electric batteries it was suggested that a super capacitor may allow systems to achieve higher energy densities; a refuelable zinc-air battery could be considered for vehicle use. While the prospect for emissions improvement of gasoline vehicles has clearly improved in recent years, the relative costs of infrastructure, vehicle and fuel for the the alternative fuels compared with gasoline demonstrate the difficulty the alternative fuels have in taking market share from gasoline. For the next decade, gasoline, propane and CNG are expected to be the dominant fuels for vehicles. After that, the leading fuel will be the one that has been most extensively researched and developed during the ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
Contents: recent trend of battery technologies; alkaline manganese battery with no mercury addition; high capacity zinc-air battery series for hearing aids; characteristics of vanadium-niobium-lithium rechargeable battery; high-energy density lithium-ion rechargeable battery; lithium polymer rechargeable battery: polymer gel electrolyte and electrode; high-capacity ni-cd battery sm120; high-capacity nickel-metal hydride battery; sealed-type batteries for electric vehicles; high-temperature-durable calcium-type battery for automobiles; sealed lead acid batteries for upss; solar cell power unit; solid oxide fuel cell (1); battery management system.
1994-08-01
Lebanon: assessment of the state of the environment.Final report
International Nuclear Information System (INIS)
The study concerns the assessment of the state of the environment in Lebanon and the identification of policy options has three specific objectives namely to determine the conditions of the environment in Lebanon after years of wars (1975-1992); to identify environmentals trends associated with Lebanon's development and to assess their sustainability; to identify policy options for environmental management. Issues of the environment concerned are both the brown issues e.g. the management of wastes and effluent arising from human activitiesand green issues, the natural resource base defined through main receptors:air, water (including coastal waters), land and terrestrial ecology sectors such as agriculture, industry, energy, transport, tourism and fisheries, population and human settlements are also studied
Independent power plant using wood waste
Energy Technology Data Exchange (ETDEWEB)
A 1 MWe power plant using waste wood fuel is to be installed at a US Marine Corps base, which will supply all wood from a landfill site. The core energy conversion technology is a down-draft gasifier supplying approximately 150 Btu/scf gas to both spark ignition and diesel dual-fuel engine-generator sets. Features of the plant design include: (1) grinding wood fuel from a wide range of waste resources, (2) specialized screening for fines removal, (3) complete tar and other waste product control without landfill disposal, and (4) use of process heat for bulk fuel drying, gasifier air pre-heating, and wastewater evaporation.
1995-08-01
Household batteries: Evaluation of collection methods
Energy Technology Data Exchange (ETDEWEB)
While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household ...
1992-01-01
Household batteries: Evaluation of collection methods
Energy Technology Data Exchange (ETDEWEB)
While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household ...
1992-12-31
Energy Technology Data Exchange (ETDEWEB)
At the 7th Healthy Buildings Conference, which was held in Singapore, 7-11 December 2003, more than 500 articles to improve public health and productivity of workers in buildings and the performance of installations. Special attention is paid to indoor air quality and thermal comfort in relation to energy efficiency. [Dutch] Op de laatste Healthy Buildings conferentie, december 2003 in Singapore, werden meer dan 500 artikelen gepresenteerd over het creeren van gezonde, productiviteit verhogende gebouwen en installaties. Deze keer lag de nadruk op binnenluchtkwaliteit en thermisch binnenklimaat, onder andere op het aspect energiezuinigheid. Opvallend was ook de aandacht die de problemen met binnenluchtkwaliteit in ontwikkelingslanden kreeg.
2004-02-01
Energy Technology Data Exchange (ETDEWEB)
This publication contains the Ordinance on Heating Costs, the Ordinance on Heating Installations, and the 1st Federal Ordinance on Emission Control (BImSchV) concerning Small-Scale Furnaces, in each case with notes and explanations. All these ordinances aim at reducing energy consumption in connection with heating; the 1st BImSchV also at air pollution abatement by lowering the permissible limiting values for soot and flue gas. The three ordinances also apply to housing property. (HSCH).
1991-01-01
Gas turbine tops 40% efficiency; features novel inlet-air cooler
Energy Technology Data Exchange (ETDEWEB)
This article reports on the world's first gas turbine to top 40% thermal efficiency in simple cycle and is now operating commercially as part of a natural-gas-fired combined-cycle cogeneration (CC) plant serving the Ottawa Health Sciences Center, Ottawa, Ont, Canada. Owned and operated by TransAlta Energy Corp, Calgary, Alta, the CC plant supplies steam and hot and chilled water to the health center and another thermal user while the electricity is sold to Ontario Hydro. Part of the project included the conversion of 15-psig steam-carrying equipment to hot-water service. Commercial success of this installation heralds a new era in the application of efficient gas turbines for power generation.
1993-02-01
The possible physical linkage between galactic cosmic rays intensity and the Earth's cloud cover is discussed using the analysis of the first indirect aerosol effect (Twomey effect) and its experimental representation as the dependence of average cloud droplet effective radius on aerosol index characterizing the aerosol concentration in the atmospheric air column of unit section. It is shown that the basic kinetic equation of the Earth's climate energy-balance model is described by the bifurcation equation (with respect to the temperature of the Earth's surface) in the form of fold catastrophe with two governing parameters defining the variations of insolation and Earth's magnetic field (or galactic cosmic rays intensity in the atmosphere), respectively. The principle of hierarchical climatic models construction, which consists in the structural invariance of balance equations of these models evolving on the different time scales, is described. ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
To gain in efficiency, lightness and volume, the hybrid and electric-powered cars will certainly follow the cellular phone path. The key of success of todays hybrid cars is the Ni-MH battery developed by Matsushita (87.5% of the market in 2004). The lithium-ion batteries will be the next step and would allow to supply 80 to 100% of the energy of the vehicle, the thermal engine becoming just an auxiliary system for additional power, autonomy and air-conditioning. Prototypes can reach today 200 to 450 km of autonomy and 130 km/h speeds with batteries of about 200 kg. If most of the safety problems linked with the Li technology have been solved, the main drawback remains the cost of the Li-ion technology. Short paper. (J.S.)
2005-09-28
Experimental studies on fumigation of ethanol in a small capacity Diesel engine
British Library Electronic Table of Contents (United Kingdom)
To diversify the mix of domestic energy resources and to reduce dependence on imported oil, ethanol is widely investigated for applying in combination with Diesel fuel to reduce pollutants, including smoke and NOx. Present work aims at developing a fumigation system for introduction of ethanol in a small capacity Diesel engine and to determine its effects on emission. Fumigation was achieved by using a constant volume carburetor. Different percentages of ethanol fumes with air were then introduced in the Diesel engine, under various load conditions. Ethanol is an oxygenated fuel and lead to smooth and efficient combustion. Atomization of ethanol also results in lower combustion temperature. During the present study, gaseous emission has been found to be decreasing with ethanol fumigation. ...
2011-01-01
Development and realization of shredder fluff recycling
Energy Technology Data Exchange (ETDEWEB)
In the past shredder fluff from automobile recycling was discarded in landfills, but shrinking landfill space and the partly hazardous content of the fluff as well as its caloric value, all resulted in efforts to turn this waste problem into an energy resource. In order to produce a fuel, the inorganic compounds have to be removed. Extensive analyses and particle size measurements were made on fluff from various shredder. For optimal separation all particles are reduced to a uniform, relatively small size. In a subsequent combined screening and air classification process, successful separation into organic and inorganic fractions is achieved. The inorganic fraction is treated in a heavy media or an eddy-current separator to recover the valuable metals, while the organic fraction is now suitable for thermal processing, such as fluidized bed gasification and using the resulting carbon as a chemical reagent.
1995-12-31
Design of a magnetic braking system
International Nuclear Information System (INIS)
A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within acceptable range with the measured value. The results will facilitate the design of magnetic braking systems.
2006-09-01
Clean combustion of solid fuels
International Nuclear Information System (INIS)
A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.
2008-01-01
Capturing the Daylight Dividend
Energy Technology Data Exchange (ETDEWEB)
Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.
2006-04-30
Brookhaven National Laboratory Coastal Meteorology Program, 1972-1983
Energy Technology Data Exchange (ETDEWEB)
Research conducted at Brookhaven National Laboratory under the Coastal Meteorology and Diffusion Research Program from 1972 to 1983 is summarized by the following study areas: Diffusion Studies, Boundary Layer Studies, Coastal Meteorology Studies, Air-Sea Interaction Studies, Coastal Transport and Diffusion Climatology, Seabreeze Modeling and Instrument Development, all supported by the US Department of Energy. Studies supported by the Nuclear Regulatory Commission, the National Science Foundation and the American Petroleum Institute are also described. A summary of a Workshop on Coastal Atmospheric Transport Processes, an account of studies in progress, recommendations for future research and a description of facilities and instrumentation available are also included. A list of all publications and presentations prepared as part of the program is given with abstracts. 7 figures, 1 table.
1983-06-01
Banana peel extract mediated synthesis of gold nanoparticles
British Library Electronic Table of Contents (United Kingdom)
Gold nanoparticles were synthesized by using banana peel extract (BPE) as a simple, non-toxic, eco-friendly 'green material'. The boiled, crushed, acetone precipitated, air-dried peel powder was used to reduce chloroauric acid. A variety of nanoparticles were formed when the reaction conditions were altered with respect to pH, BPE content, chloroauric acid concentration and temperature of incubation. The reaction mixtures displayed vivid colors and UV-vis spectra characteristic of gold nanoparticles. Dynamic light scattering (DLS) studies revealed that the average size of the nanoparticles under standard synthetic conditions was around 300nm. Scanning electron microscopy and energy dispersive spectrometry (EDS) confirmed these results. A coffee ring phenomenon, led to the aggregation of th...
2010-01-01
Banana peel extract mediated novel route for the synthesis of silver nanoparticles
British Library Electronic Table of Contents (United Kingdom)
Bio-inspired silver nanoparticles were synthesized with the aid of a novel, non-toxic, eco-friendly biological material namely, banana peel extract (BPE). Boiled, crushed, acetone precipitated, air-dried peel powder was used for reducing silver nitrate. Silver nanoparticles were formed when the reaction conditions were altered with respect to pH, BPE content, concentration of silver nitrate and incubation temperature. The colorless reaction mixtures turned brown and displayed UV-visible spectra characteristic of silver nanoparticles. Scanning electron microscope (SEM) observations revealed the predominance of silver nanosized crystallites after short incubation periods. When the reaction mixtures were incubated for 15 days, some micro-aggregates were also observed. Energy dispersive spectr...
2010-01-01
Banana peel extract mediated novel route for the synthesis of palladium nanoparticles
British Library Electronic Table of Contents (United Kingdom)
Bio-inspired palladium nanoparticles were synthesized by using banana peel extract (BPE), a non-toxic eco-friendly material. Boiled, crushed, acetone precipitated, air-dried peel powder was used to reduce palladium chloride. The palladium nanoparticles were characterized by using UV-Visible spectroscopy, scanning electron microscope-energy dispersive spectra (SEM-EDS) and X-ray diffraction (XRD) analysis. Dynamic light scattering (DLS) studies revealed the average size of nanoparticles to be 50nm. Fourier transform infra red spectroscopy (FTIR) implicated the role of carboxyl, amine and hydroxyl groups in the synthetic process. This paper thus describes a novel green method for the synthesis of palladium nanoparticles.
2010-01-01
Appendix B : Environment report : Securing a sustainable future for Canada`s oil sands industry
Energy Technology Data Exchange (ETDEWEB)
The oil sands industry in Canada was said to be committed to environmentally sustainable economic development, i.e. a development that recognizes the mutual dependence of a healthy environment and a healthy economy. To indicate progress toward this goal, the report pointed out the investment of millions of dollars in environmental research and tens of millions of dollars in plant equipment already made. These infrastructure investments have paid dividends in terms of energy conservation, reduction of greenhouse gas emissions, land reclamation, air quality monitoring, water conservation, and water quality and biodiversity protection. A number of recommendations governing provincial jurisdictions over regulations were made. Particular concern was expressed over fairness, and overlapping of regulations by different levels of government.
1995-12-01
A study on the cooling effects of greening in a high-density city: An experience from Hong Kong
British Library Electronic Table of Contents (United Kingdom)
Greening is a useful mitigation strategy for planners mainly from a visual perspective. For high-density urban living environment such as Hong Kong, urban greening helps cooling the air and providing shade; it also helps lowering building energy consumption by providing a better outdoor boundary condition. Many researchers have also suggested that greening may be employed as a strategy for combating the ill effects of urban Heat Island (UHI). Working towards a set of better greening guidelines for urban planners, the current paper first provides a comprehensive review of planning with urban greening. It then describes parametric studies that have been conducted to investigate the preferred location, amount, and types of vegetation for urban planning. The parametric studies employed the num...
2012-01-01
A study of solar-powered, high-altitude unmanned aerial vehicles
British Library Electronic Table of Contents (United Kingdom)
Purpose ? Aims to present a methodology for analysing a solar-electric, high-altitude, long-endurance, unmanned aircraft. Design/methodology/approach ? The study focuses on the aerodynamics, flight performance and power requirements of a heavier-than-air, solar-electric, HALE UAV. The methodology is founded on using an analytical approach to determine the power required to undertake various flight manoeuvres. An analytical approach is also undertaken in determining the intensity of the solar radiation available to the aircraft. Finally to demonstrate the methodology, a HALE concept was generated and evaluated. Findings ? When using estimates of current solar-electric propulsion and energy conversion efficiencies, the HALE concept was only able to sustain year round, level flight up to lati...
2006-01-01
A comparison of flue gas desulfurization processes
As coal becomes more and more important as a power plant fuel in this time of energy shortage and the combustion of high-sulfur coals that would impair air quality, efforts have been made to devise efficient processes to control sulfur dioxide emission. Besides desulfurization before combustion, flue gas desulfurization is considered the most promising method that could also be applicable to all other fossil fuels. In this article, the flue gas desulfurization processes are briefly reviewed, and processes with highest use and with high potential for future use are compared from technical and economical points of view. In the selection of a desulfurization process, it is very important to consider the capacity of the plant, fuel type and fuel-to-sulfur ratio, availability and price of the reagent to be used, type, price, and market of side products, disposal problems of wastes, and environmental factors.
2000-04-01
Ultra-high temperature strength properties on Mod.9Cr-1Mo steel
Energy Technology Data Exchange (ETDEWEB)
A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were acquired. (2) Short-term mechanical properties of Mod.9Cr-1Mo steel were evaluated based on the results of ...
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
In the paper presented, an attempt is made to describe quantitatively the room air motion by diffuse air distribution. Since solving the problem theoretically, seems to be hopeless at present, only an experimental solution seems to promise success. Experiments with diffuse air distribution offer suitable preconditions. With this kind of air introduction into the room, a relatively regular distribution of room air motion can be expected. A further simplification will be achieved by isotherme flow conditions. The first goal of the experiments was to establish whether the velocities measured are reproducible to demonstrate, and can be brought into a functional connection. The room air motion is a measured value which changes temporarily and locally quite largely, far more than is customary with technical measurements. From there, a second task arises, i.e. to ...
1985-08-01
Radon in soil gas survey in Curitiba (Brazil)
International Nuclear Information System (INIS)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air ...
2002-10-08
Pollutant Emission Factors from Residential Natural Gas Appliances: A Literature Review
Energy Technology Data Exchange (ETDEWEB)
There is a need to reduce air pollutant emissions in some U.S. urban regions to meet federal and state air quality guidelines. Opportunities exist for reducing pollutant emissions from natural gas appliances in the residential sector. A cost-benefit analysis on various pollutant-reducing strategies is needed to evaluate these opportunities. The effectiveness of these pollutant-reducing strategies (e.g., low-emission burners, energy conservation) can then be ranked among themselves and compared with other pollutant-reducing strategies available for the region. A key step towards conducting a cost-benefit analysis is to collect information on pollutant emissions from existing residential natural gas appliances. An extensive literature search was conducted to collect data on residential natural-gas-appliance pollutant emission factors. The literature primarily describes laboratory tests and may not reflect actual emission ...
1996-08-01
Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil
International Nuclear Information System (INIS)
Current work presents the results of more than 100 measurements of 222Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222Rn concentration were processed taking into account the volume of water sample and its temperature, atmospheric pressure and the total volume ...
Energy Technology Data Exchange (ETDEWEB)
This study investigated the engine performance and emissions of a supercharged engine fueled by hydrogen and ignited by a pilot amount of diesel fuel in dual-fuel mode. The engine was tested for use as a cogeneration engine, so power output while maintaining a reasonable thermal efficiency was important. Experiments were carried out at a constant pilot injection pressure and pilot quantity for different fuel-air equivalence ratios and at various injection timings without and with charge dilution. The experimental strategy was to optimize the injection timing to maximize engine power at different fuel-air equivalence ratios without knocking and within the limit of the maximum cylinder pressure. The engine was tested first with hydrogen-operation condition up to the maximum possible fuel-air equivalence ratio of 0.3. A maximum IMEP of 908 kPa and a thermal efficiency of about 42% were obtained. Equivalence ratio could not be ...
2010-01-15
Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
Space HVAC systems are to provide hygienical room air. Air change is necessary because of pollutants released from materials or production processes but also because of the presence of humans or animals who consume oxygen. Poor room climate and/or poor air hygiene do not only reduce the felt comfort but may also result in a loss or profitability and higher sickness rates. (orig.)
2006-07-01
ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS
Energy Technology Data Exchange (ETDEWEB)
A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolyzation process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)
1999-07-01
Decline of Ambient Air Pollution Levels and Improved Respiratory Health in Swiss Children
UK PubMed Central (United Kingdom)
The causality of observed associations between air pollution and respiratory health in children is still subject to debate. If reduced air pollution exposure resulted in improved respiratory health...Full Text Available
2005-11-01
UK PubMed Central (United Kingdom)
Studies of the associations between air pollution and hospital admissions and emergency room use are reviewed, including studies of air pollution episodes, time-series analyses, and cross-sectional...Full Text Available
1993-07-01
The use of foam to improve liquid lifting from low-pressure gas wells
Energy Technology Data Exchange (ETDEWEB)
Gas well load up is the loss of available reservoir energy due to the accumulation of liquids in the wellbore over time, and these liquids arise from liquids (hydrocarbons and water) condensed from the gas. Accumulation of these liquids near the wellbore can cause severe reduction to complete loss of available transport energy. A systematic experimental approach was undertaken to evaluate the performance of foam in removing liquids from the bottom of wells. The objectives of the research were: (1) to determine the efficiency of liquid lifting with foam; and (2) to compare the effects of surfactant type and concentration on liquid lifting. A flowloop successfully simulated the effects of completions with and without packer for low-pressure gas well with liquid production. In the base-case runs (air and water flow), the two phase flow regime was mostly annular. Liquid lifting is improved in general when a surfactant is used. ...
1999-07-01
Test-bed for compact ventilation units; Pruefstand fuer Kompaktlueftungsgeraete fuer Komfortlueftung
Energy Technology Data Exchange (ETDEWEB)
This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal bridges. The test installation is described ...
2005-12-15
Sustainable schools. Better than traditional schools?
Energy Technology Data Exchange (ETDEWEB)
In the United Kingdom several educational buildings were built in the last decades with a strong environmental ethos, real icons of a new generation of low-energy sustainable buildings. For some of the buildings the performance was assessed. Also in the Netherlands several new concepts were developed for sustainable schools during the last years. This is an interesting topic as many of those schools had problems concerning energy efficiency, indoor air quality and thermal comfort. In the case of sustainable schools much effort was put into the design process of the schools to try to find better solutions to face the problems of the traditional designs. This resulted in different solution concepts, which raises the question which are better school concepts. From the literature three evaluations from the UK and one overview of five sustainable educational buildings from the Netherlands are given, which show that sustainable ...
2008-10-15
Solar expriment begins at Atlanta school. [George A. Towns Elementary School
The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind conditions will be recorded. The inlet temperatures, outlet temperatures, and the mass flow rates to the ...
1976-03-01
On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir
Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the ...
1992-01-01
International Nuclear Information System (INIS)
The present volume on energy and the environment discusses space power requirements, space power systems, space power systems hardware, space radioisotope systems, space solar arrays, space solar cells, space station power, and terrestrial applications of aerospace technology. Attention is given to NASA future space power requirements and issues, the design of a battery charger for the NASA EOS Space Platform, in situ carbon dioxide fixation on Mars, and a preliminary design update of the CRAF/Cassini Power Subsystem. Topics addressed include concentrator testing using projected images, solar power satellites and demonstraton platforms from nonterrestrial materials, a mass sensitivity analysis of lunar orbiting beam power systems, and a power-beaming-based infrastructure for space power. Also discussed are fiber-optic sensors for aerospace electrical measurements, the preliminary design of a mobile lunar power supply, advanced power systems for EOS, and ...
1991-08-03
Ground source heat for heat pumps; Erdgekoppelte Waermequellen fuer Waermepumpen
Energy Technology Data Exchange (ETDEWEB)
Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen Verbreitungsschub. In dem durch Heiz- und Kuehlbedarf charakterisierten Umfeld kann sie Ihre Vorteile voll nutzen. Fuer Deutschland kommt eine Schaetzung zu einem Potential der erdgekoppelten Waermepumpen zur Substition ...
1996-12-31
International Nuclear Information System (INIS)
The increasing diffusion of small-scale energy systems within the distributed generation (DG) paradigm is raising the need for studying the environmental impact due to the different DG solutions in order to assess their sustainability. Addressing the environmental impact calls for building specific models for studying both local and global emissions. In this framework, the adoption of natural gas-fueled DG cogeneration technologies may provide, as a consequence of cogeneration enhanced overall energy efficiency and of natural gas relatively low carbon content, a significant reduction of global impact in terms of CO2 emissions with respect to the separate production of electricity and heat. However, a comprehensive evaluation of the DG alternatives should take into account as well the impact due to the presence of plants spread over the territory that could increase the local pollution, in particular due to CO and NOx, and thus could worsen the ...
2008-10-01
A space crystal diffraction telescope for the energy range of nuclear transitions
Energy Technology Data Exchange (ETDEWEB)
This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & ...
1995-04-01
Study of the thermal plasma etching at atmospheric pressure on silica rods
International Nuclear Information System (INIS)
Etching of SiO_2 rods has been obtained with a dc torch with argon as the process gas in an air environment at atmospheric pressure; the high temperature of the plasma jet causes vaporization of the exposed area. The apparatus and torch operative parameters have been set up to obtain a depth etch rate of up to 0.6 mm min"-"1 corresponding to 0.826 g min"-"1. An enthalpy probe has been employed to monitor the plasma conditions before the thermal plasma etching process and from the experimental etch rate a surface rod temperature of T_s_u_r = 2057 K has been derived. Etching has been obtained with uniformity over the entire exposed area with peak to peak differences below 1%. The plasma to rod heat transfer has been simulated using a commercial CFD code Fluent (copyright). The model consists of a non-steady two-dimensional simulation for a compressible turbulent fluid, with an adapted grid calculation. Boundary conditions have been set out using the enthalpy probe ...
2004-04-21
Methods for evaluating long-term changes in thermal resistance of vacuum insulation panels
Energy Technology Data Exchange (ETDEWEB)
Vacuum insulation panels (VIP) offer excellent thermal resistance properties that can enhance the energy efficiency of insulating systems, save space and contribute to energy consumption reductions. However, VIPs are not used much in Canada, and new commitments to carbon dioxide reductions has created the need to study the prospect of using VIPs in various components of a building envelope. For that reason, assessment methods for the applicability and sustainability of VIPs for use in building envelope construction were developed. There are practical aspects regarding the long-term performance and application of VIPs in building construction. Air molecules and water molecules can permeate through the foil and seams of the VIPs, causing a reduction in thermal resistance. This paper addresses some of the test methods that may accelerate long term changes in thermal resistance. Results were presented from tests using elevated ...
2005-07-01
Nuclear reactor with external structure cooling by natural convection
International Nuclear Information System (INIS)
The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.
Energy Technology Data Exchange (ETDEWEB)
The measurement of air pollutants is no more sufficient. It is necessary to assess the risk induced by air pollution, and then to put in place actions to reduce it. The air quality monitoring takes into account different pollutants: nitrogen oxides, carbon monoxide, particulates for the traffic; sulfur dioxide and particulates for use of fuel or coal or chemical transformations in air; ozone and nitrogen dioxide from hydrocarbon and nitrogen oxides emissions; the use of simulation methods allow to calculate the concentrations levels for these pollutants taken as indicators. (N.C.)
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
In order to promote the use of natural gas air-conditioning systems in the tertiary sector, Gaz de France (the French gas utility) in association with Electricite de France (EdF) and the French chamber of council engineers (CICF) have created the Acerclim organization which aims at certifying the quality of the design, realization and exploitation of air processing and air-conditioning installations according to the ISO 9001 criteria. This article describes this quality procedure named 'CHSB Air'. (J.S.)
2002-07-01
Wing-surface-jet interaction characteristics of an upper-surface ...
Engine flow simulation was provided by four separately mounted air ejectors connected to a high-pressure air supply. The engine nacelle center lines were ...
Transforming Civil Engineering. Air Force Civil Engineer ...
... Civil Engineering Page 2. ... 4. TITLE AND SUBTITLE Transforming Civil Engineering (Air Force Civil Engineer, Volume 15, Number 1, 2007) 5a. ...
2011-05-14
The Numerical Weather Prediction System at the Italian Air ...
... Title : The Numerical Weather Prediction System at the Italian Air Force Weather Service: Impact of Non-Conventional Observations and Increased ...
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
This report documents the technical basis by which the workplace air monitoring and sampling program is operated in the 324 and 327 Buildings.
2000-01-17
Evaluation of Two Microclimate Cooling Air Vests on a Heated ...
... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...
1992-12-01
Computer-Aided Acquisition and Logistic Support Gateway ...
... Army, Navy, Air Force Procedures (JANAP) 128 AUTODIN Operating Procedures. ... JANAP = Joint Army, Navy, Air Force Procedures ...
1989-09-01
Characterizing Differential Air-Core Eddy Current Probes
... Accession Number : ADD331250. Title : Characterizing Differential Air-Core Eddy Current Probes. Corporate Author : Personal ...
A Danish decision-support GIS tool for management of urban air quality and human exposures
Energy Technology Data Exchange (ETDEWEB)
A new prototype model system named AirGIS has been developed to support local authorities in air quality management for big Danish cities. The system is based on the Danish operational street pollution model (OSPM), technical and cadastral digital maps and Danish national administrative databases on buildings, cadastres and populations. It applies a geographic information system (GIS). AirGIS estimates ambient air pollution levels at high temporal and spatial resolutions. The model system enables mapping of traffic emissions, air quality levels and human exposures at residence addresses, at workplace addresses and in streets. Mapping and scenario results can be compared with air quality limits. Impact assessment of traffic air pollution abatement measures can also be carried out. (author)
2001-07-01
Survey of UEC estimates for space heating, DHW heating, and appliances energy usage
Energy Technology Data Exchange (ETDEWEB)
Natural Resources Canada commissioned an informal survey in which 18 organizations, mainly utilities from across Canada were contacted by letter or fax to gather data regarding unit energy consumption (UEC) of space heating, domestic hot water (DHW) heating and appliances. The data was used in updating and refining the residential energy end-use model used at NRCan. The survey included energy load, UEC, efficiency, and per cent saturation for both space heating and water heating equipment for all fuel types including electric, natural gas, oil, wood and propane used in single detached, single attached, apartment and mobile homes. A list of UEC and per cent saturation for major appliances such as refrigerators, freezers, clothes washers and dryers, cooktop/ovens, central air-conditioners, and lighting is also included in the survey. The collected data was presented separately for each organization. The ...
1998-03-01
SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA
Energy Technology Data Exchange (ETDEWEB)
Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no cooling ...
2008-09-30
A desiccant dehumidifier for electric vehicle heating
Energy Technology Data Exchange (ETDEWEB)
Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in the vehicle. Either strategy results in a ...
1996-09-01
The Refuelable Zinc-air Battery: Alternative Techniques for Zinc and Electrolyte Regeneration
Energy Technology Data Exchange (ETDEWEB)
An investigation was conducted into alternative techniques for zinc and electrolyte regeneration and reuse in the refuelable zinc/air battery that was developed by LLNL and previously tested on a moving electric bus using cut wire. Mossy zinc was electrodeposited onto a bipolar array of inclined Ni plates with an energy consumption of 1.8 kWh/kg. Using a H{sub 2}-depolarized anode, zinc was deposited at 0.6 V (0.8 kA/m{sup 2}); the open circuit voltage was 0.45 V. Three types of fuel pellets were tested and compared with results for 0.75 mm cut wire: spheres produced in a spouted bed (UCB); coarse powder produced by gas-atomization (Noranda); and irregular pellets produced by chopping 1-mm plates of compacted zinc fines (Eagle-Picher, Inc.). All three types transported within the cell. The coarse powder fed continuously from hopper to cell, as did the compacted pellets (< 0.83 mm). Large particles (> 0.83 mm; Eagle-Picher and UCB) ...
2006-01-19
This report covers the first year of operation of a fuel cell power plant, installed by PPL Spectrum, Inc. (PPL) under contract with the United States Coast Guard (USCG), Research and Development Center (RDC). The fuel cell was installed at Air Station Cape Cod in Bourne, MA. The project had the support of the Massachusetts Technology Collaborative (MTC), the Department of Energy (DOE), and Keyspan Energy. PPL selected FuelCell Energy, Inc. (FCE) and its fuel cell model DFC{reg_sign}300 for the contract. Grant contributions were finalized and a contract between PPL and the USCG for the manufacture, installation, and first year's maintenance of the fuel cell was executed on September 24, 2001. As the prime contractor, PPL was responsible for all facets of the project. All the work was completed by PPL through various subcontracts, including the primary subcontract with FCE for the manufacture, ...
2004-06-30
Energy Technology Data Exchange (ETDEWEB)
A 2-stage cold (non-tritium) PMR system was tested with the ITER mix in61 days of continuous operation. No decrease in performance was observed over the duration of the test. Decontamination factor (DF) was found to increase with decreasing inlet rate. Decontamination factors in excess of 1.4 {times} 10{sup 5} were obtained, but the exact value of the highest DF could not be determined because of analysis limitations. Results of the 61-day test were used to design a 2-stage PMR system for use in tritium testing. The PMR system was scaled up by a factor of 6 and built into a glovebox in the Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory. This system is approximately 1/5th of the expected full ITER scale. The ITER mix was injected into the PMR system for 31 hours, during which 4.5 g of tritium were processed. The 1st stage had DF = 200 and the 2nd stage had DF = 2.9 {times} 10{sup 6}. The overall DF = 5.8 {times} 10{sup 8}, which is greater than ITER ...
1996-12-31
International Nuclear Information System (INIS)
A 2-stage cold (non-tritium) PMR system was tested with the ITER mix in 61 days of continuous operation. No decrease in performance was observed over the duration of the test. Decontamination factor (DF) was found to increase with decreasing inlet rate. Decontamination factors in excess of 1.4x10"5 were obtained, but the exact value of the highest DF could not be determined because of analysis limitations. Results of the 61-day test were used to design a 2-stage PMR system for use in tritium testing. The PMR system was scaled up by a factor of 6 and built into a glovebox in the Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory. This system is approximately 1/5"t"h of the expected full ITER scale. The ITER mix was injected into the PMR system for 31 hours, during which 4.5 g of tritium were processed. The 1"s"t stage had DF =200 and the 2"n"d stage had DF=2.9x10"6. The overall DF=5.8x10"8, which is greater than ITER requirements. 3 refs., 10 figs.
1996-06-16
The Schenberg spherical antenna: status report
International Nuclear Information System (INIS)
Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new set of transducers, microwave oscillators, ...
2009-09-14
Synthesis of nanoporous carbon as a gas adsorbent by reverse replication process of silica template
Energy Technology Data Exchange (ETDEWEB)
Porous carbon with high surface area and pore volume was prepared by a reverse replication process and its toluene equilibrium adsorption behavior was investigated. The preparation process of the porous carbon was composed of following sub-processes in series: synthesis and template preparation of silica gel, impregnation and polymerization of DVB monomer in silica template, carbonization of DVB polymer in a silica-polymer composite, and HF-assisted selective etching of silica in carbon-silica composite, The prepared porous carbon was nano porous and had ultrahigh specific surface area (2007 m{sup 2}/g) and large pore volume (3.07cm{sup 3}/g). The nanoporous carbon showed rapid toluene adsorption rate and good toluene adsorption capacity, compared with a commercial Y-type zeolite, In the present study, a reverse replication process to prepare nanoporous carbons will be introduced and its application potential as a gas adsorbent will be discussed. (author). 17 ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
Abstract: We report for the selective-area chemical synthesis of semiconductor single-crystal organic nanowires of silver-tetracyanoquinodimethane (Ag-TCNQ). Straight and smooth Ag-TCNQ nanowires can be produced and patterned on micrometer and nanometer scale on silicon substrates covered with a thin layer of Ag film through the reaction of TCNQ and Ag in a simple gas-solid chemical reaction process. Ag-TCNQ nanowires are characterized by UV-vis, IR and Raman spectroscopy, respectively. The Ag-TCNQ nanowires grows preferentially along the [100] direction of strong - stacking of Ag-TCNQ molecules. Nanodevices based on these nanowires are fabricated using focus ion beam (FIB) technique. Electrical properties are characterized and I-V hysteresis is observed, which shows memory effect with electrical switching of three orders on-off ratio. These nanowires could be potential for use in optical storage, ultrahigh-density nanoscale memory and logic devices.
2008-09-01
Energy Technology Data Exchange (ETDEWEB)
Research and development has been performed on photochromic materials expected to be used in ultra-high density recording, high resolution indication and photoswitches. With regard to molecular orientation in the ternary system mixed LB film, the result of structural analysis by XPM spectrum revealed that the acceptor constituent in the LB film is so structured that it is separated and laminated with two other constituents, and that the sensitizer constituent and the donor constituent are not recognized of being separated definitely. Regarding the electron movement reaction in the solid phase system, a photo-current measuring experiment was carried out on the laminated film which is vacuum-deposited with the ternary system comprising of the donor, sensitizer, and acceptor. It was concluded that the observed photo-current reflects the electron movement reaction in the solid phase as it is. For the photo-current in the LB film, increase in the photo-current was ...
1990-03-01
Mechanism of ageing in irradiated polymers
Energy Technology Data Exchange (ETDEWEB)
Samples of ultra-high molecular weight polyethylene (UHMWPE) and nylon 66, of grades suitable for use in medical prostheses, were subjected to irradiation using a /sup 60/Co source. The effects of a 10 Mrad dose on percentage crystallinity, tensile behaviour and dynamic mechanical response were established 3 days after irradiation at intervals over a one year period. Crystallinity in UHMWPE was found to increase progressively during this period with consequent changes in mechanical behaviour. It is proposed that the observed ageing process arises from the breakdown of metastable groups in the polymer, which are formed on irradiation, with consequent release of long inter-lamella tie chains. This removes an inhibition to crystal perfection processes, which can occur at room temperature in polyethylene. Infra-red spectroscopic evidence supports the proposal that the metastable species is peroxy or hydroperoxy and that this decomposes on ageing to a carbonyl group, ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Fe-Ni-Mn martensitic steels are one of the major groups of ultra-high strength steels that have good mechanical properties and ductility in as annealed condition but they suffer from severe inter-granular embitterment after aging. In this paper, the effect of heavy shaped cold rolling and wire drawing on the mechanical properties of Fe-Ni-Mn steel was investigated. This process could provide a large strain deformation in this alloy. The total strain was {epsilon} {approx}7. Aging behavior and tensile properties of Fe-10Ni-7Mn were studied after aging at 753 K. The results showed that the ultimate tensile strength and ductility after cold rolling, wire drawing and aging increased up to 2540 MPa and 7.1 %, respectively, while the conventional steels show a premature fracture stress of 830 MPa with about zero ductility after aging.
2010-07-01
International Nuclear Information System (INIS)
Fe-Ni-Mn martensitic steels are one of the major groups of ultra-high strength steels that have good mechanical properties and ductility in as annealed condition but they suffer from severe inter-granular embitterment after aging. In this paper, the effect of heavy shaped cold rolling and wire drawing on the mechanical properties of Fe-Ni-Mn steel was investigated. This process could provide a large strain deformation in this alloy. The total strain was #epsilon# #approx#7. Aging behavior and tensile properties of Fe-10Ni-7Mn were studied after aging at 753 K. The results showed that the ultimate tensile strength and ductility after cold rolling, wire drawing and aging increased up to 2540 MPa and 7.1 %, respectively, while the conventional steels show a premature fracture stress of 830 MPa with about zero ductility after aging.
2010-07-01
Hydrogen transport behavior of Timetal-21S alloy
International Nuclear Information System (INIS)
Ti-15Mo-2.7Nb-3Al-0.2Si (Timetal-21S), a metastable #beta#-titanium alloy, is a candidate material for titanium matrix composite structures in hydrogen-fueled hypersonic planes because of its excellent formability and adequate mechanical properties in the 500--800 C temperature range. The alloy is strengthened through the precipitation of fine #alpha# particles in the #beta# matrix. The mechanical properties and microstructures are controlled by a solutionizing/aging heat treatment. A major concern in using titanium alloys in hydrogen service is the embrittlement caused by the precipitation of hydrides. It is believed that the large solubility of hydrogen in the #beta#-phase would preclude the precipitation of hydrides in Beta titanium alloys, especially at low hydrogen pressures. However, depending on the hydrogen content, a shift in the ductile/brittle transition temperatures to levels much higher than room temperature has been reported for Timetal-21S alloy. The objective of the ...
Focused ion-beam line profiles: A study of some factors affecting beam broadening
Energy Technology Data Exchange (ETDEWEB)
The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ``wings`` that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least for the lighter ions ...
1995-11-01
Focused ion-beam line profiles: A study of some factors affecting beam broadening
International Nuclear Information System (INIS)
The current--density profile of a focused ion beam (FIB) has a central peak accompanied by broader ''wings'' that, while unimportant in lithographic applications, can lead to unwanted effects during an implantation operation. The origin of the wings, and hence the best way to minimize them, is not clear and needs further study. We have measured the line profiles of several of the ions available in our FIB machine as a function of a number of variables, under ultrahigh vacuum (UHV) conditions. No effects are observed from changes in emission current or deliberate defocusing of the objective lens. There are some changes with beam aperture and/or current, but the biggest differences seem to be associated with a change of source type and hence, possibly, with a change in the source/extractor configuration or in the alloy and the emission process. The wing amplitudes are appreciably lower than many previously observed, and their profiles, at least for the lighter ions ...
Energy Technology Data Exchange (ETDEWEB)
Negative ion electrospray ionization (ESI) coupled with high field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) allows for the direct detection of acidic NSO compounds in petroleum. The technique requires no chromatographic separation, is able to distinguish 18 different compound classes (e.g., neutral nitrogen, carboxylic acids and oxygenates), and can identify {approx}14,000 distinct masses by ultra-high mass resolution and mass accuracy. We previously studied three crude oils from different geological origins [Organic Geochemistry 33 (2002b) 743-759]. Here, we expand our research by comparing two source-equivalent Smackover oils of different levels of thermal maturity. We observe clear differences in the distribution of NSO compound classes, types (number of rings plus double bonds within a class), and number of alkyl carbons. With increasing thermal stress, the relative amount of sulfur and oxygen containing compounds decreases, ...
2004-07-01
Abrasive waterjet cutting of high purity uranium metal: Topical report
The Abrasive Waterjet Cutting process was evaluated to determine if the equivalent could be utilized for cutting uranium metal at the Feed Materials Production Center (FMPC). In the process, a thin stream of ultrahigh pressure water carried grit material through a designated piecepart. In order to be acceptable for use at the FMPC, the equipment must be cost effective, minimize waste, and be adaptableto operating in an enclosure, and improve health and safety conditions. Observation of the cutting process showed that health and safety aspects could be optimized with an enclosed ventilated system. Also the equipment can be easily automated. The cutting action produced sparks similar to the sparks caused by a grinding operation. The sparks are captured in a water container under the workpiece that not only catches the sparks, but also serves to dissipiate the stream of water and residues produced by the cut. Metallographic tests performed on the cut surface of the ...
1988-01-01
... 15 minutes Time lapse video Time Lapse Recorder (Panasonic) SVHS 4-seconds
Thermal performance of solar air collectors with a passive heat transfer augmentation technique
Energy Technology Data Exchange (ETDEWEB)
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
2000-07-01
Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials
International Nuclear Information System (INIS)
It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.
2007-12-17
In situ air stripping using horizontal wells. Innovative technology summary report
Energy Technology Data Exchange (ETDEWEB)
In-situ air stripping employs horizontal wells to inject or sparge air into the ground water and vacuum extract VOC`S from vadose zone soils. The horizontal wells provide better access to the subsurface contamination, and the air sparging eliminates the need for surface ground water treatment systems and treats the subsurface in-situ. A full-scale demonstration was conducted at the Savannah River Plant in an area polluted with trichloroethylene and tetrachloroethylene. Results are described.
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
Climate change is not only dangerous but also expensive. On the other hand, air pollution abatement measures are costly as well. Scientists of the Microeconomics Department investigated how air pollution abatement and cost efficiency can best be combined. (orig.)
2005-07-01
An experimental study of the ventilation performance of cold-air distribution systems
Energy Technology Data Exchange (ETDEWEB)
The ventilation performance of cold-air distribution systems was investigated in a full-scale test room for three different designs of ceiling-mounted diffusers: a large square radial, a small square radial, and two linear diffusers. The supply air temperature was 38 F (3.3 C). Tests were conducted with internal heat loads and with and without furnishings. The local mean ages of air, air diffusion effectiveness, and contaminant-removal efficiency were measured using tracer gas techniques to assess the performance of the ventilation system in maintaining adequate air quality conditions in the occupied region. Air velocities and temperatures were also measured in the occupied region to calculate the air diffusion performance index (ADPI). It was found that the cold-air distribution system provided satisfactory ...
1994-12-31
Performance of air-augmented waterjet thrusters
This report describes an investigation of the performance of air-augmented waterjet thrusters. The investigation is divided into two parts. Part one describes a study of the injection of large diameter air bubbles to reduce heat transfer between the air and water and, thus, increase the thrust. This study is done analytically by solving the appropriate, governing equations. The results indicate that the approach is very worth-while since thrust can be increased ten percent as compared to air-augmentation with small bubbles. Several practical systems are discussed for injecting large air bubbles. Part two is an experimental investigation of the thrust produced under a wind range of conditions. The results show that a thrust increase of more than 20 percent can be achieved by air-augmentation. Further, the performance improves for larger thrust nozzles.
1976-11-01
Energy Technology Data Exchange (ETDEWEB)
By means of a numerical simulation model (PHOENICS) the air flow and the distribution of the air concentration in an operating room of an hospital have been calculated. Comparisons were made for 11 different conditions (m[sup 3]/h air flow, speed of the air supply in the centre, the middle and outside of the room), of which six cases are discussed in this article, in order to optimize the air flow pattern in the room. The calculations were conducted for the so-called Howorth system. It is shown that the inlet velocity profile with a higher inlet velocity in the center zone of the hood gives the best results. The calculated results were validated by some measurements and experiments with smoke. 7 figs., 2 tabs., 8 refs.
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports thermal comfort and indoor air quality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of acceptability of IAQ associated with the UFAC ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this research is to experimentally study the efficiency of a new-design plate collector used to heat air in a new desalination humidification-dehumidification process. In fact, in such processes, the air solar collectors work at unusual experimental parameters (forced convection, elevated air humidity, high solar irradiation). At these stressed experimental conditions, few published works are available in literature. Furthermore, the comparison of the efficiency of collectors running with normal air humidity content (about 10-20 g kg{sup -1}) and air of elevated humidity (20-50 g kg{sup -1}) have not been published to our knowledge. In the present investigation, a new air solar plate collector was designed and developed for its use in a desalination process. Moreover, a characterization of such collector was performed under different experimental ...
2005-07-01
A study on the treatment of radioactive liquid wastes using synthetic by air intake system
International Nuclear Information System (INIS)
In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the ...
2003-11-27
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no ...
2007-06-30
MEASUREMENT OF HYDROPEROXIDES DURING THE TEXAS 2000 AIR QUALITY STUDY
International Nuclear Information System (INIS)
Hydroperoxides are important atmospheric oxidants. They are responsible for most of the oxidation of aqueous-phase SO(sub 2) to sulfate in the northeastern United States, resulting in the formation of acid precipitation and visibility-reducing sulfate aerosol (Penkett et al., 1979; Lind et al., 1987; Madronich and Calvert, 1990; Tanner and Schorran, 1995). Atmospheric hydrogen peroxide (H(sub 2)O(sub 2) or HP) is produced by the self-reaction of hydroperoxyl radicals (HO(sub 2)); higher organic peroxides are produced by reaction of HO(sub 2) with alkylperoxyl radicals (RO(sub 2)). Peroxyl radicals, along with OH, are chain carriers in the complex photochemical process that produces tropospheric ozone. Thus, concentrations of peroxides and their free radical precursors depend on solar intensity and ambient concentrations of water vapor, ozone, NO(sub x) (NO+ NO(sub 2)), and VOCs (volatile organic compounds). Several investigators have demonstrated that HP and hydroxymethyl hydroperoxide ...
Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense
Energy Technology Data Exchange (ETDEWEB)
Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)
1997-05-01
Effect of Carbon Dioxide in the Air on Zinc-air Cell
Energy Technology Data Exchange (ETDEWEB)
The electrolyte was brought into contact with air and potassium carbonate was measured with various contact time in order to check the defect of carbon dioxide in the air on zinc-air cell. The relationship between potassium carbonate concentration in electrolyte and battery capacity was also studied. The potassium carbonate concentration in the electrolyte. The rate of carbon dioxide absorption was mainly affected by the pore size of hydrophobic membrane. Our study showed that adapting the pore of hydrophobic membrane decreased the loss of cell discharge performance due to the presence of carbon dioxide or water vapor in the atmosphere. 7 refs., 12 figs., 1 tab.
1999-04-01
Alterations in resting oxygen consumption in women exposed to 10 days of cold air
Energy Technology Data Exchange (ETDEWEB)
Repeated exposure to cold air reduces the metabolic response to cold air exposure in man. The purpose of this investigation was to measure the change in resting metabolic rate (RMR) with exposure to 22C air and 4C air during a 12 day period. Four women sat in 22C air for 45 min followed by 45 min in 4C air each day for ten days. The authors measured RMR during a 45 min period in 22C air followed by 45 min in 4C air on four days. All subjects began their morning exposures on a Monday within 2 days of the onset of menses completing the study on a Friday, 12 days later. Subjects dressed in a T-shirt, shorts and cotton socks. During 45 min of exposure to warm air, RMR remained steady at 10% of VO{sub 2peak} on Day 1 and 10% on Day 5. RMR during exposure to warm air significantly ...
1991-03-11
International Nuclear Information System (INIS)
Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and calculated (CATHARE code version V15a mod 2.1) results of the test NCg-l. It was carried ...
2001-03-20
Energy Technology Data Exchange (ETDEWEB)
The main problems with the use of neat vegetable oils in diesel engines are higher smoke levels and lower thermal efficiency as compared to diesel. The problem can be tackled by inducting a gaseous fuel in the intake manifold along with air. In this investigation, hydrogen is used as the inducted fuel and rubber seed oil (RSO), rubber seed oil methyl ester (RSOME) and diesel are used as main fuels in a dual fuel engine. A single cylinder diesel engine with rated output of 4.4 kW at 1500 rpm was converted to operate in the dual fuel mode. Dual fuel operation of varying hydrogen quantity with RSO and RSOME results in higher brake thermal efficiency and significant reduction in smoke levels at high outputs. The maximum brake thermal efficiency is 28.12%, 29.26% and 31.62% with RSO, RSOME and diesel at hydrogen energy share of 8.39%, 8.73% and 10.1%, respectively. Smoke is reduced from 5.5 to 3.5 BSU with RSOME and for RSO it is from 6.1 to 3.8 BSU ...
2008-11-15
Relevance of mixed layer scaling for daytime dispersion based on RAPS and other field programs
Energy Technology Data Exchange (ETDEWEB)
A brief review and assessment of field measurement programs that provide data for mixed layer diffusion research is presented. The majority of programs emphasize either the meteorological aspects of the mixed layer or plume characterization. Few programs are available that provide the complimentary blend of plume and appropriate meteorological measurements needed to adequately validate mixed layer diffusion theory. Three major U.S. EPA (Environmental Protection Agency) field programs that provide data bases for model development and validation of mixed layer diffusion processes are described and discussed in more detail. The Regional Air Pollution Study (RAPS) focused on measurements of surface and mixed layer turbulent transport processes in the urban environment. The Tennessee Plume Study (TPS) obtained a database with coincident measurement of boundary layer turbulent structure and plume dispersion for a large coal-fired power plant in nonuniform terrain over ...
1983-01-01
Reactive magnetron sputtering of hard Si-B-C-N films with a high-temperature oxidation resistance
International Nuclear Information System (INIS)
Based on the results obtained for C-N and Si-C-N films, a systematic investigation of reactive magnetron sputtering of hard quaternary Si-B-C-N materials has been carried out. The Si-B-C-N films were deposited on p-type Si(100) substrates by dc magnetron co-sputtering using a single C-Si-B target (at a fixed 20% boron fraction in the target erosion area) in nitrogen-argon gas mixtures. Elemental compositions of the films, their surface bonding structure and mechanical properties, together with their oxidation resistance in air, were controlled by the Si fraction (5-75%) in the magnetron target erosion area, the Ar fraction (0-75%) in the gas mixture, the rf induced negative substrate bias voltage (from a floating potential to -500 V) and the substrate temperature (180-350 deg. C). The total pressure and the discharge current on the magnetron target were held constant at 0.5 Pa and 1 A, respectively. The energy and flux of ions bombarding the ...
2005-11-01
International Nuclear Information System (INIS)
Growing of PV for electricity generation is one of the highest in the field of the renewable energies and this tendency is expected to continue in the next years. Due to the various seasonal, hourly and daily changes in climate, it is relatively difficult to find a suitable analytic model for predicting the performance of a grid-connected photovoltaic (GCPV) plant. In this paper, an artificial neural network is used for modelling and predicting the power produced by a 20 kWp GCPV plant installed on the roof top of the municipality of Trieste (latitude 45 deg. 40'N, longitude 13 deg. 46'E), Italy. An experimental database of climate (irradiance and air temperature) and electrical (power delivered to the grid) data from January 29th to May 25th 2009 has been used. Two ANN models have been developed and implemented on experimental climate and electrical data. The first one is a multivariate model based on the solar irradiance and the ...
2010-12-01
The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
More than two and a half years of monitoring of a passive house school and day-care centre in Frankfurt a. M. show comfortable indoor climate and good air quality. The space heat consumption is low and shows savings of approximately 90 % as compared to average existing schools. Excellent performance was also achieved in terms of primary energy. The results of further analyses of the efficient ventilation system with heat recovery, the perimeter insulation as an alternative to floor slab insulation and the influence of the air change due to the entrance door are presented. (Abstract Copyright [2008], Wiley Periodicals, Inc.) [German] Ueber zweieinhalb Jahre Monitoring einer Passivhaus-Schule und Kindertagesstaette (KiTa) in Frankfurt a.M. zeigt behagliche raumklimatische Bedingungen bei guten Luftqualitaeten. Die Heizwaermeverbrauchswerte liegen wie erwartet niedrig und zeigen Einsparungen um 90 % gegenueber dem Durchschnitt ...
2008-02-15
Life-cycle analysis and external costs in transportation
International Nuclear Information System (INIS)
The assessment of greenhouse gas impacts in the US shows that against a baseline gasoline vehicle, the impact of including the full fuel cycle generally reduces the relative advantages of alternative transportation fuels. While a switch to diesel is estimated to save 30% as compared to gasoline, the savings from natural gas/LPG are (around 20%), for ethanol from corn (8%) and for battery electricity vehicles using power from coal (6%) are much smaller. This is largely due to the use of LCA rather than end-use comparisons. However, the results also show that there would be large savings from the use of ethanol from fuel cells using methanol (39%) or natural gas (50%), while ethanol from wood in a conventional engine appears to have the greatest savings (63%). In external costs of motor vehicle use, analysis results were presented for both air pollution and energy security impacts (including SPR, military expenditures, macro-economic costs and ...
Energy Technology Data Exchange (ETDEWEB)
'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
This project is aimed at development of optimum combustion technology with diversified fuels, e.g., naphtha and LCO, for gas turbines and others as power sources for topographical energy supply. The combustion under the microgravity is also investigated using the underground facilities at Japan Microgravity Center. Described herein are the FY 2000 results. For construction of combustion model and simulation, the combustion reactions for various liquid fuels are simplified to calculate ignition delay, adiabatic flame temperature and laminar burning velocity with an error less than about 3%. The microgravity combustion experiments are conducted for spray dispersed into a cylinder, to find flame propagation velocities changing with the vaporization characteristics of liquid fuels, and also to construct the combustion models. The premixed turbulent combustion simulation program is developed using a probability density function and analyzed. Development of new ...
2001-03-01
Cooling of nuclear power stations with high temperature reactors and helium turbine cycles
International Nuclear Information System (INIS)
On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable design of the overall 'cold end' to be expected. In the so-called unit range it is ...
Compressed hydrogen fuelled vehicle at ENEA: Status and development
International Nuclear Information System (INIS)
The world's 500 million road vehicles using internal combustion engines account for roughly half of global oil consumption and, in Italy, for about 50% of all nitrogen oxide and 90% of carbon monoxide emissions. In efforts to conserve petroleum reserves and reduce air pollution, research programs are being conducted to develop hydrogen fueled automotive engines. Hydrogen combustion products are carbon dioxide free, and when burned with a large excess of air, this fuel produces water vapour and only small amounts of nitrogen oxides. Hydrogen fueled vehicles can be made to operate in a dual fuel mode so as to allow the use of petrol or diesel fuel in travel over long distances. Currently, because technical and economic difficulties relevant to hydrogen fuel storage limit driving range and payload (there are bulk and weight problems in compressed gas and metal hydride storage systems, and cost problems in cryogenic storage), only limited research ...
1993-06-22
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results ...
1993-06-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final ...
1994-07-01
International Nuclear Information System (INIS)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results ...
1993-01-01
Advanced hydrogen fueled internal combustion engines
Energy Technology Data Exchange (ETDEWEB)
The Hydrogen Program at Sandia National Laboratories is developing internal combustion engine generators for application in series hybrid vehicles and stationary power units. The program consists of two approaches: investigating the utilization of hydrogen in a conventional crankshaft driven engine and in an advanced free piston configuration. The conventional engine program has taken the direction of utilizing the unique ability to spark ignite homogeneous fuel/air mixtures of hydrogen at low equivalence ratios to achieve low NO{sub x} emissions and high thermal efficiency. The goal is to translate the indicated thermal efficiency of single-cylinder engines into multicylinder configurations achieving at least 40% brake thermal efficiency. When coupled to an electrical generator, the fuel to electricity conversion efficiency would be approximately 37%. A modified Perkins 3.152 Diesel engine is currently being tested and has achieved an indicated thermal efficiency ...
1998-01-01
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw material of the globe ...
Water induction studies in a hydrogen-diesel dual-fuel engine
Energy Technology Data Exchange (ETDEWEB)
Power output of a hydrogen-diesel dual-fuel engine is limited by the onset of knock as the percentage of heat input derived from hydrogen increased beyond a certain limit. Earlier work carried out at the Internal Combustion Engines Laboratory, Indian Institute of Technology, Madras, indicates that this knock sets in when the induced hydrogen exceeds about 60% of input energy at a pilot diesel quantity of 30% of full load diesel amount. At higher rates of hydrogen induction, the richer hydrogen-air mixture is more prone to knocking. Hardly any information is available on the possibilities of improving the knock limited power output of a hydrogen-diesel dual-fuel engine. Water can serve as a powerful internal coolant in decreasing the unburned mixture temperature because of its high latent heat. This paper presents the results of our investigation on improving the knock limited power output when water is inducted with the intake charge of a ...
1987-01-01
Vapor phase lubrication of a Ni-based superalloy
Energy Technology Data Exchange (ETDEWEB)
In addition to ceramics, alloys such as tool steel and nickel- and iron-based superalloys are being considered for high temperature applications such as missile bearings and low heat rejection engines. Studies were made to lubricate a nickel-based superalloy at 500{degrees}C, by using a vaporized aryl phosphate ester, at a concentration of 0.1% in air. From deposition and wear studies it was found that it was impossible to form a good polymeric coating on the superalloy surface. Energy dispersive X-ray analyzer (EDXA) analysis showed that this was due to minute quantities of aluminum in the alloy segregating to the surface, upon being heated to 500{degrees}C, forming a passive oxide coating. It was necessary to activate the surface, in order to lubricate the material successfully. A method of activation by electrodepositing the surface with a layer of iron oxide was developed. Once activated, a good lubricous polymer was formed on the ...
1995-03-01
Time-Resolved Aerosol Collector for CCSEM/EDX Single Particle Analysis
Energy Technology Data Exchange (ETDEWEB)
An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the relative contribution of ...
2003-01-02
Thermal effect on superhydrophobic performance of stearic acid modified ZnO nanotowers
Energy Technology Data Exchange (ETDEWEB)
The thermal desorption of stearic acid on superhydrophobic zinc oxide nanotowers has been investigated. The stearic acid passivated zinc oxide nanotowers provide a very high contact angle of {approx}173 {+-} 1.1 deg. with a very low hysteresis of {approx}1.4 {+-} 0.5 deg. due to the presence of a binary structure composed of several nanosteps on each nanotower of height {approx}700 nm that eventually reduces the area of contact between the drop and the nanotowers and trapping more air as revealed by the field emission scanning electron microscopy images. The superhydrophobic performance of these nanotowers, however, declines following annealing at elevated temperatures. Fourier transform infrared spectra show a reduction in the intensity of stearic acid -CH{sub n} peaks at elevated temperatures revealing the cause of the decrease in contact angle and confirming the occurrence of thermal desorption at 184 deg. C. The corresponding activation ...
2008-02-28
Energy Technology Data Exchange (ETDEWEB)
A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor air quality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.
2006-09-15
Technology development, evaluation, and application (TDEA) FY 1997 progress report
Energy Technology Data Exchange (ETDEWEB)
The public expects that the Los Alamos National Laboratory (LANL) will operate in a manner that prevents negative impacts to the environment and protects the safety and health of its employees and the public. To achieve this goal within budget, the Department of Energy (DOE) and LANL must develop new and improved environment, safety, and health (ES and H) technologies and implement innovative, more cost-effective ES and H approaches to operations. In FY95, the Environment, Safety, and Health (ESH) Division initiated a Technology Development, Evaluation, and Application (TDEA) program. The purpose of this unique program is to test and develop technologies that solve LANL ES and H problems and improve the safety of LANL operations. This progress report presents the results of 10 projects funded in FY97 by the TDEA Committee of the Environment, Safety, and Health Division. Products generated from the projects funded in FY97 included implementation of radiation worker ...
1998-05-01
Energy Technology Data Exchange (ETDEWEB)
In this study, WO{sub 3} thin films were grown on glass substrates using an aqueous solution containing tungstate (NH{sub 4}){sub 2}WO{sub 4} as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at T{sub s} = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T({lambda}) and reflectance R({lambda}) spectra in 300-1800 nm domain. The ...
2009-11-13
International Nuclear Information System (INIS)
In this study, WO3 thin films were grown on glass substrates using an aqueous solution containing tungstate (NH4)2WO4 as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at Ts = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T(?) and reflectance R(?) spectra in 300-1800 nm domain. The refractive and absorption indexes, n and k were ...
2009-11-13
British Library Electronic Table of Contents (United Kingdom)
Here in the present paper, we report on growth of stoichiometric and nonstoichiometric nanostructured heterojunction solar cell of CdS/CuInSXSe2-X varying X from 0 to 2 in the interval of 0.5 using cost effective, simple, chemical ion exchange method at room temperature on ITO glass substrate. The as-grown varying composition solar cells annealed at 200degreeC in air and characterized for structural, compositional, optical and illumination studies. The X-ray diffraction pattern obtained from CdS/CuInSXSe2-X solar cell confirms the formation of CuInSe2, CuInS0.5Se1.5, CuInS1Se1, CuInS1.5Se0.5 and CuInS2 phases having tetragonal structure with varying crystallite size from 19, 19.37, 28, 33 and 20nm respectively. The energy dispersive X-ray analysis (EDAX) confirms the expected elemental com...
2011-01-01
Spray evaporation in direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
A theoretical model for spray evaporation in a direct-injection diesel engine is developed taking into consideration the unsteady evaporation period. For this purpose, the liquid droplets temperatures, masses and velocities are studied. Solving the conservation of energy and mass equations together with the equation of state, a set of ordinary differential equations is achieved. These equations are solved using a special numerical technique. This technique, based on a fourth-order Runge-Kutta integration method is described. Calculated results are compared with experimental data and were found to be in good agreement. Analysis of the obtained results shows that for the combustion-chamber constituents, temperature is a dominant factor in the spray-evaporation process and in shaping the temperature history of the evaporating droplets. The combustion-chamber pressure and the spray volume play a secondary role in the evaporation process. Also, it was found that the ...
1987-01-01
Second law analysis of compressible flow through a diffuser subjected to constant heat flux at wall
International Nuclear Information System (INIS)
Entropy generation is equivalent to destruction of available work (exergy). The useful energy is destroyed due to the intrinsic irreversibility associated within thermodynamic systems. Exergy analysis can be used as an effective basis for the development and improvement of systems design not only in the overall perspective but also in the individual component level. Second law analysis provides a useful tool to identify the irreversibility in any thermal system. This study presents the investigation of local and total entropy generation in compressible flow through a diffuser. Air is used as the fluid. Uniform heat flux boundary condition is applied at the wall. Two dimensional solution of velocity and temperature fields are obtained using the CFD code FLUENT. Distribution of entropy generation rate is investigated throughout the volume of the fluid as it flows through the diffuser. Regions of high entropy generation in the diffuser have been ...
2010-12-01
Reducing VMTs through Transit-On-Demand with GPS and satellite communications
Energy Technology Data Exchange (ETDEWEB)
As a partial solution to the problem of increasing foreign petroleum imports,urban congestion, and air pollution from automobiles, NREL researchers have successfully demonstrated a transportation concept called Transit-On-Demand (TOD). TOD uses the global positioning system (GPS) to locate all vehicles in a fleet, two-way communications between the vehicles and a central computer-server, and advanced dispatching and routing software to control the movement of vehicles within the fleet. Reducing the vehicle-miles-travelled (VMTs) through implementing efficient transportation systems such as TOD, results in less energy being required for transportation and a decrease in the amount of required imported petroleum. Through development of an advanced world wide web site and use of the new Java{trademark} Internet programming language, the demonstration allows visitors to the web site to see updates of vehicle position on a map every 20 seconds,while ...
1996-10-01
Power generation using coir-pith and wood derived producer gas in diesel engines
Energy Technology Data Exchange (ETDEWEB)
Partial combustion of biomass in the gasifier generates producer gas that can be used for heating purposes and as supplementary or sole fuel in internal combustion engines. In this study, the potential of coir-pith and wood chips as the feedstock for gasifier is analyzed. The performance of the gasifier-engine system is analyzed by running the engine for various producer gas-air flow ratios and at different load conditions. The system is experimentally optimized with respect to maximum diesel savings and lower emissions in the dual fuel mode operation while using coir-pith and wood chips separately. The performance and emission characteristics of the dual fuel engine are compared with that of diesel engine at different load conditions. Specific energy consumption in the dual fuel mode of operation is found to be in the higher side at all load conditions. The brake thermal efficiency of the engine while using wood chips in the dual mode ...
2006-10-15
Partial natural-gas firing of Cupola furnaces. Delvis naturgasfyring af kupolovne
Energy Technology Data Exchange (ETDEWEB)
The aim was to investigate conditions relating to the substitution of natural gas for part of the amount of cinders previously used as fuel in an existing cupola furnace used in an iron foundry. The process of retrofitting is described. The principle solution is that four gas burners are placed symmetrically around the furnace immediately above the melting zone. They are mounted in separate fire boxes in such a way that they point downwards in order to prevent the fire box being filled with materials from the furnace, which would cause damage to the burners. The burners are continuously controlled to produce an output of 720 - 2620 kW and with 0.5 - 1.5 excess air. This solution was successful although it was found necessary (in order to achieve a satisfactory quality of resulting molten material) to add extra cinders to the furnace resulting in a reduction of only 9% of total cinders used, instead of the hoped-for 15%. The melting temperature was stabilized to ca. ...
1994-03-01
Ozone production at the National Synchrotron Light Source
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10"1"2 and 10"1"5 eV . cm"-"3 . sec"-"1. The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10"-"1"9 cm"3 . eV"-"1. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene aspects of operation and possible control ...
1998-09-20
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10/sup 12/ and 10/sup 15/ eV/sup . /cm/sup -3 . /sec/sup -1/. The measured ozone half-life was 37+-2 min. The measured G-value was 2.69+-0.14 mol/100 eV and the ozone destruction factor k was less than 5 x 10/sup -19/cm/sup 3//eV. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppm ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene aspects of operation and ...
Oxidation inhibition of sulfite in dual alkali flue gas desulfurization system.
A laboratory-scale well-mixed thermostatic reactor with continuously blasting air was used to investigate the oxidation inhibition of sulfite in dual alkali flue gas desulfurization (FGD) system. The effects of operating parameters such as pH value and catalyst concentration on the oxidation were studied. Sodium thiosulfate was used in the system, and was found that it significantly inhabited the sulfite oxidation. In the absence of catalyst, sodium thiosulfate at 12.67 mmol/L had an inhibition efficiency of approximately 98%. While in the presence of catalyst, sodium thiosulfate at 26.72 mmol/L had an inhibition efficiency less than 85.0%. The oxidation reaction order of sulfite in the sodium thiosulfate was determined to be -1.90 and -0.55 in the absence and presence of the catalyst, respectively. Apparent activation energy of oxidation inhibition was calculated to be 53.9 kJ/mol. Pilot tests showed that the consumption rate of thiosulfate ...
2007-01-01
Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea
Energy Technology Data Exchange (ETDEWEB)
An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed ...
1998-07-01
New intelligent monitor for CANDU type NPP
International Nuclear Information System (INIS)
Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy water leakage, (b) reduces the possibility of health hazard. In order to attain this goal of safety function, ...
2009-10-12
Energy Technology Data Exchange (ETDEWEB)
Petroleum is the unchallenged energy market leader in West Germany,having a share of 42%; natural gas accounts for 16-17%. West Germany imports 29% of its natural gas from the Soviet Union, 28% from the Netherlands, 14% from Norway, and 1% from Denmark. In West Germany many-branched natural gas distribution system is operated, equipped with a.o. 21 installations for underground storage which results in a great flexibility of the system. Because of the preferential treatment given to the use of coal as fuel for power plants the share of natural gas has decreased to the present 6% in the last ten years. In the indutrial sector the share is 18%. Strict air pollution abatement measures ('TA-Luft') favour the use of natural gas. However, duty has been levied on the use of natural gas per January 1st, 1989. For space heating of houses and commercial buildings the share of natural gas is 27%. 7 figs., 9 ills.
1989-10-01
Monoenergetic Gamma-Rays from Non-Minimal Kaluza-Klein Dark Matter Annihilations
We investigate monoenergetic gamma-ray signatures of Z^1 dark matter annihilations in a non-minimal Universal Extra Dimensions model. The self-interactions of the non-Abelian Z^1 gauge boson give rise to a large number of contributing Feynman diagrams that do not exist for annihilations of the Abelian gauge boson B^1, which is the standard Kaluza-Klein dark matter candidate. We find that the annihilation rate is indeed considerably larger for the Z^1 than for the B^1. Even though relic density calculations indicate that the mass of the Z^1 should be larger than the mass of the B^1, the predicted fluxes are of the same order of magnitude. We compare our results to existing experimental limits, as well as to future sensitivities, for image air Cherenkov telescopes, and we find that the limits are reached already with a moderately large boost factor. However, the realistic prospects for detection depend on the energy resolution, as well as on the ...
2011-01-01
Internalizing externalities of electricity generation: An analysis with MESSAGE-MACRO
Energy Technology Data Exchange (ETDEWEB)
This paper examines the global impacts of a policy that internalizes the external costs (related to air pollution damage, excluding climate costs) of electricity generation using a combined energy systems and macroeconomic model. Starting point are estimates of the monetary damage costs for SO{sub 2}, NO {sub X} , and PM per kWh electricity generated, taking into account the fuel type, sulfur content, removal technology, generation efficiency, and population density. Internalizing these externalities implies that clean and advanced technologies increase their share in global electricity production. Particularly, advanced coal power plants, natural gas combined cycles, natural gas fuel cells, wind and biomass technologies gain significant market shares at the expense of traditional coal- and gas-fired plants. Global carbon dioxide emissions are lowered by 3% to 5%. Sulfur dioxide emissions drop significantly below the already low level. The ...
2007-02-15
Internalizing externalities of electricity generation: An analysis with MESSAGE-MACRO
Energy Technology Data Exchange (ETDEWEB)
This paper examines the global impacts of a policy that internalizes the external costs (related to air pollution damage, excluding climate costs) of electricity generation using a combined energy systems and macroeconomic model. Starting point are estimates of the monetary damage costs for SO{sub 2}, NOX, and PM per kWh electricity generated, taking into account the fuel type, sulfur content, removal technology, generation efficiency, and population density. Internalizing these externalities implies that clean and advanced technologies increase their share in global electricity production. Particularly, advanced coal power plants, natural gas combined cycles, natural gas fuel cells, wind and biomass technologies gain significant market shares at the expense of traditional coal- and gas-fired plants. Global carbon dioxide emissions are lowered by 3% to 5%. Sulfur dioxide emissions drop significantly below the already low level. The policy ...
2007-02-15
Impact of low-rank coal properties on advanced power systems
Energy Technology Data Exchange (ETDEWEB)
Advanced coal-fired combined-cycle power systems under development and demonstration have the potential to increase generating efficiency to approach 50%, reduce the cost of electricity by up to 20%, and meet stringent standards on emissions of SO{sub x}, NO{sub x}, fine particulates, and air toxic metals. Integrated gasification combined cycle, pressurized fluidized-bed combustion, and externally fired combined cycle systems rely on different high-temperature combinations of heat exchange, gas filtration, and sulfur capture to meet these requirements. The success of these systems when operated on low-rank coals depends importantly on the behavior of the ash. This paper focuses on the behavior of ash in an intermediate-scale transport gasifier coupled with a hot-gas cleanup system. The work reported is part of the overall program on hot-gas cleanup and the transport reactor development unit (TRDU) located at the Energy and Environmental ...
1996-12-31
Hydrogen and natural gas buses in the USA. The cleanest machines ever built
Energy Technology Data Exchange (ETDEWEB)
In 1983, the first modern urban transit bus powered by an alternative transportation fuel took to the roads in the USA. A little more than a decade later, about 2.5% of all USA buses are powered by alternative transportation fuels and about 20% of the new bus orders for delivery by 1998 will be powered by alternative fuels, mostly by natural gas. There are over 2,200 natural gas buses in operation or on order, plus about 600 additional buses powered by other alternative fuels. When these orders are completed, alternative fuel buses will constitute over 4.4% of the urban bus fleet in the USA. The widespread use of natural gas buses in the USA provides an important transition pathway for hydrogen vehicles because of the similarities between distribution, refueling and onboard energy storage technologies for the two fuels. Projects demonstrating advanced hybrid-electric buses powered by natural gas or hydrogen and projects demonstrating hydrogen fuel cells in buses ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid Tests (LOFT), part of an international safety program for commercial power reactors. ...
2005-02-01
International Nuclear Information System (INIS)
New physical objects, ispalators based on free soap films, exhibit persistent flows of the soap solution in open and closed volumes in air with additions of gases of the C_8F_1_8 type (p = 20 Torr) at temperature drops on the films of the order of tenths and hundredths of kelvin. The flows move continuously at a velocity of 5 - 20 cm s"-"1. It is found that the parts of an inclined ispalator film show anomalous behaviour upon heating: their weight increases and they move downward over the film, whereas the unheated parts of the film move upward. Continuous radial vortex flows accompanied by the formation and washing of the regions of a thin black film are observed on circular films in closed volumes upon their uniform external cooling by evaporating water for 5 - 10 hours. The rapid flows make film ispalators the efficient heat carriers, which operate at small temperature drops (tenths and hundredths of kelvin) and surpass copper in the amount of thermal ...
2002-05-31
International Nuclear Information System (INIS)
High temperature fatigue crack growth (FCG) and creep crack growth (CCG) experiments have been conducted in air on weld metal, heat affected zone (HAZ) and base metal of the austenitic Alloy 800 and the nickel base Alloy 617. Tests were performed on specimens machined from pipes, in the temperature range 550-900 deg. C. The crack propagation mode was examined. At all temperatures and for both materials, FCG of base metal was found to be the highest, whereas the weld metal exhibited the lowest FCG rate. The FCG rate in the HAZ was found to lie in between of those observed for base and weld metal. The crack propagation mode remained transgranular in base metal and transdendritic in weld metal at all temperatures. CCG behaviour could be described using the energy rate integral C*. Base metal and weld metal exhibited similar CCG rate at same C*. The crack propagation mode under CCG condition was found to be intergranular in base metal and HAZ and ...
1993-08-15
Energy Technology Data Exchange (ETDEWEB)
The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are ...
1999-04-02
Experimental modelling of a pilot lignocellulosic pellets stove plant
Energy Technology Data Exchange (ETDEWEB)
Small-scale stoves, producing heat and hot water, are suited for domestic purposes. In order to optimise their efficiency when using lignocellulosic pellets, an important task is to do research on their real performance. The general behaviour depends on many operational factors (air flow and humidity, pressure, etc), dimension and pellet characteristics (moisture, size, raw material, density, friability, etc). In this paper, the first results and general performance of a 24 kW pellet fixed bed stove pilot plant are presented. The plant has been designed to study pellet combustion in the laboratory. The main targets are to reduce emissions of pollutants and to improve energy efficiency. Different situations can be simulated and tested due to its flexible design. Temperatures, pressures, flows and emissions are measured and analysed. An extensive study of different load conditions is presented through the application of both an experiment design ...
2004-12-01
Electronic fuel injection techniques for hydrogen powered i. c. engines
Energy Technology Data Exchange (ETDEWEB)
Numerous studies have demonstrated the advantages of hydrogen as a fuel for Otto Cycle engines due to high thermal efficiency and low exhaust pollutant levels. Characteristic of hydrogen engine operation using premixed intake charge formation is a problem of pre-ignition resulting in an intake manifold backfire. Additional problems include high NO production when using certain equivalence ratios and power output degradation due to low fuel energy/volume density. Techniques for direct and port fuel injection are discussed as means for overcoming these problems. Emphasis is placed on the need for total engine control, integrating control of fuel injection, ignition timing, intake air throttling, and vehicle subsystems within a central electronic unit. An electronically actuated fuel injection valve and a prototype electronic control system are developed. These are applied in port and direct injection system geometries, and evaluated in engine ...
1980-01-01
Eco-profiling Inco Limited production : a case study
Energy Technology Data Exchange (ETDEWEB)
Inco Ltd., a primary producer of nickel and an important producer of copper, cobalt, precious metals and sulphur products, initiated a project in 1997 to conduct eco-profiles of its worldwide metal production in an effort to improve its internal processing, marketing and environmental management. The study made it possible to recognize some internal and external benefits including the opportunity to gain operating efficiencies and improved process/product design, the development of better environmental performance indicators to guide decision making, and the availability of comprehensive product related environmental data to meet the informational needs of customers, designers, engineers and governments. This paper described the life cycle assessment (LCA) process used by Inco to conduct the study. A life cycle inventory (LCI) was used to quantitatively calculate resource requirements and environmental burdens associated with a product system over the life cycle of a product. LCI ...
2000-07-01
Development of a methodology to assess organometallic effects on bioenergetic systems
Energy Technology Data Exchange (ETDEWEB)
A methodology for assessing the impact of subacute concentrations of organometallic agents on bioenergetic and oxidative damage processes in animals, cells and energy transducing subcellular organelles is being developed. Several of the assays are noninvasive and thus lend themselves to human tests. At the whole-animal level we utilize a treadmill chamber where physiological parameters of exercising animals are monitored. These include parameters of whole animals' work performance such as oxygen consumption, carbon dioxide evolution and endurance. Oxidative damage can be monitored in experiments by analyzing expired air of the animals for ethane and n-pentane. These alkanes correlate with lipid peroxidation in vivo. At the cellular and subcellular levels, respiratory activity, lipid peroxidation and free radical species are assayed. Respiratory activity is measured in muscle homogenates and isolated mitochondria using substrates which ...
1981-06-01
International Nuclear Information System (INIS)
In general, over the course of the time, the phenomenon of acceleration in physical development may be observed, i.e. the children and adults of the next generation are taller and heavier than in former generation. Our data presented in this paper show a regular trend of acceleration in the development on Vietnamese, but the trend is still slow and was mostly probably influenced by our difficulties in a long time of war. It is hoped that, the acceleration in the development may be increased in the future following the economical acceleration of our country, however it is known that the ratio between the length of different parts of human body is a specific characteristic for human race, sex and group age. Therefore we may estimate these ratio for the prolongation of the utilization of our measured physical data. The result of studies on water balance of Vietnamese living in comfortable environment air temperature conditions and working in hot environment with ...
1998-02-01
Energy Technology Data Exchange (ETDEWEB)
This paper evaluates a new power tower concept that offers significant benefits for commercialization of power tower technology. The concept uses a molten nitrate salt centralreceiver plant to supply heat, in the form of combustion air preheat, to a conventional combined-cycle power plant. The evaluation focused on first commercial plants, examined three plant capacities (31, 100, and 300 MWe), and compared these plants with a solar-only 100-MWe plant and with gas-only combined-cycle plants in the same three capacities. Results of the analysis point to several benefits relative to the solar-only plant including low energy cost for first plants, low capital cost for first plants, reduced risk with respect to business uncertainties, and the potential for new markets. In addition, the concept appears to have minimal technology development requirements. Significantly, the results show that it is possible to build a first plant with this concept ...
1994-10-01
Combined cycle power plant with integrated low temperature heat (LOTHECO)
International Nuclear Information System (INIS)
The major driver to enhance the efficiency of the simple gas turbine cycle has been the increase in process conditions through advancements in materials and cooling methods. Thermodynamic cycle developments or cycle integration are among the possible ways to further enhance performance. The current paper presents the possibilities and advantages from the LOTHECO natural gas-fired combined cycle concept. In the LOTHECO cycle, low-temperature waste heat or solar heat is used for the evaporation of injected water droplets in the compressed air entering the gas turbine's combustion chamber. Following a description of this innovative cycle, its advantages are demonstrated by comparison between different gas turbine power generation systems for small and large-scale applications, including thermodynamic and economic analysis. A commercial gas turbine (ALSTOM GT10C) has been selected and computed with the heat mass balance program ENBIPRO. The results from the ...
2004-08-01
Cogeneration in air separation cryogenic plants; Cogeracao em plantas criogenicas de separacao de ar
Energy Technology Data Exchange (ETDEWEB)
A thermal and economic study, carried on by using the first and second law of thermodynamics concepts demonstrated the economic feasibility of the cogeneration system, and proposed modifications to be done in the studied cryogenic plant, a typical T-240 NA MPL3 plant. The thermodynamic analysis showed that the second law efficiency of the processes could be improved, together with a 12% electric energy consumption reduction. Four cogeneration schemes were analyzed with both the first and second laws of thermodynamics and, then, the economic analysis was performed. Rankine, Brayton, Otto and Combined gas-steam basic cycles were used in this analysis.The combined gas-steam cycle was shown to be more economically feasible than others. Thermal and electric loads were well balanced, resulting in a higher second law efficiency. Although the initial investment for the modification was higher, the savings resulted to be higher, turning into a higher rate of return of the ...
2000-07-01
Climate change: the Intergovernmental Panel on Climate Change impacts assessment
Energy Technology Data Exchange (ETDEWEB)
The report was prepared for the IPCC by Working Group II. The remit of Working Group II was to describe the environmental and socioeconomic implications of possible climate changes over the next decades caused by increasing concentrations of greenhouse gases. The scenarios used include the following features: an effective doubling of atmospheric CO{sub 2} between now and 2025-2050; a consequent increase of global mean temperature of 1.5-4.5{degree}C; an unequal global distribution of the temperature increase; a sea level rise of 0.3 to 0.5m by 2050. The impacts of possible climate change were assessed for the following: agriculture and forestry; natural terrestrial ecosystems; hydrology and water resources; human settlements including the energy, transport and industrial sectors; human health; air quality and changes in UV-B radiation; oceans and coastal zones; seasonal snow cover; ice and permafrost. Further action is recommended. 1015 refs., ...
1990-01-01
International Nuclear Information System (INIS)
In this study, perovskite type oxide YAlO_3 has been doped with different amounts of the divalent cation Ca to synthesize Y_1_-_xCa_xAlO_3_-_#delta# (x = 0-0.21) compositions. The effect of dopant concentration on the crystal structure and electrical properties of YAlO_3 synthesized by citrate gel route has been investigated. The phase purity of the samples has been carried out using X-ray diffraction. The microstructural evaluation of the samples has been conducted by scanning electron microscopy and energy dispersive spectrum analysis. Thermal analysis has been conducted to monitor the decomposition of the intermediate products. The electrical conductivity studies have been performed using a.c. impedance spectroscopy as a function of temperature in the range 200-800 "oC in air. The Y_0_._9_4Ca_0_._0_6AlO_3_-_#delta# composition exhibits a total conductivity of 2.5 mS/cm at 800 "oC.
2010-04-30
Challenges in validating the sterilisation dose for processed human amniotic membranes
Energy Technology Data Exchange (ETDEWEB)
Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10{sup -1}. This paper describes our experience in using the IAEA Code of Practice in conducting the ...
2007-11-15
Energy Technology Data Exchange (ETDEWEB)
The results of an experimental investigation of the performance of a small bore engine with a swirl chamber when operating as a dual fuel engine with commercial methane as the gaseous fuel were presented in this paper. The experiment involved using a 3-dimensional computational fluid dynamics model to predict the performance of the engine. A detailed chemical kinetics for the gaseous fuel component, consisting primarily of methane and a reduced detailed chemical kinetics for the diesel fuel while considering the turbulent combustion processes an associated performance of a dual fuel engine with a swirl chamber were incorporated in the simulation. The study experimentally and numerically investigated the effects of changes in the quantities of the liquid fuel pilot and gaseous fuels on the combustion processes, engine performance, cyclic variations, and emissions. The paper discussed the experimental approach and results. It also discussed the simulation of the dual fuel engine ...
2007-07-01
A unified theory of radon transport in porous media: Model benchmark and soil parameter evaluations
Energy Technology Data Exchange (ETDEWEB)
This report documents the activities by Rogers and Associates Engineering Corporation personnel in the second year of a grant from the Office of Health and Environmental Research at the US Department of Energy. The project objective is to integrate theories of all significant radon generation and transport mechanisms into a unified, self-consistent theory. During the second year of the project, the following activities were performed. Several field permeabilities were measured to develop a soils data base for a simple permeability correlation. Simple soil gas permeability and radon diffusion coefficient correlations were developed from the RAE data base. A methodology was developed to characterize the air permeabilities and radon diffusion coefficients of soils in general, and the Soil Conservation Service soil classifications in particular. The RAETRAN code was benchmarked against two different sets of measurements. Using RAETRAD, a ...
1990-04-01
A dynamic model of a locomotive diesel engine and electrohydraulic governor
Energy Technology Data Exchange (ETDEWEB)
As part of a comprehensive simulation of a prototype locomotive propulsion system, a detailed model has been developed which predicts the dynamic response of an experimental 2-stroke, turbocharged and intercooled diesel engine. Engine fueling and brake torque are computed from regression equations derived from an extensive data base. Corrections are applied to the calculated steady-state torque to account for dynamic deviations of in-cylinder trapped air-fuel ratio from the steady-state value. The engine simulation accurately represents the operation of the turbo-charger, which is gear-driven at low turbocharger speeds, and freewheels through an overrunning clutch when exhaust energy accelerates the turbocharger beyond its geared speed. Engine fueling level, ie, rack, is determined from a dynamic simulation of an electrohydraulic governor which responds to the difference between the desired and the actual engine speeds. The governor ...
1988-01-01
A - Z Index : Environmental Energy Technologies Division
Buildings Energy-Efficient Research Laboratories Energy Efficiency in Federal Facilities Energy Efficiency Standards Group Energy Efficient Windows Collaborative Energy &...
2011-07-15
Thermal performance of phase change wallboard for residential cooling application
Energy Technology Data Exchange (ETDEWEB)
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat ...
1997-04-01
Energy Technology Data Exchange (ETDEWEB)
In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective transportation systems, parking, inter-region ...
2003-07-01
International Nuclear Information System (INIS)
A community greenhouse gas emission and energy inventory is an important tool to help local governments plan, implement and monitor climate change mitigation strategies and sustainable energy systems. Inventories can also facilitate a number of other local priorities such as air quality management; integrated land-use and transportation planning; infrastructure optimization and planning; and community economic development planning. The British Columbia government's community energy and emissions inventory initiative (CEEI) intends to collect and centralize high-quality geocoded data to generate high-value community inventories for the province's 185 local governments. This report presented strategic guidance for a comprehensive community emissions inventory system based on a high level review of international best practices. The report described the project objective and scope; guiding principles; ...
Energy Technology Data Exchange (ETDEWEB)
There are a multitude of cost centers in the typical coal mine, and almost as many ways to calculate their individual and collective effect on the bottom line. The costs of explosives is, in some ways, very difficult to determine without consideration of drilling, loading, hauling and breaking costs. Saving a nickel in explosive costs, for example, could end up costing a dollar more in crushing expenses. Typically, mines request quotations for explosives products on a weight basis. Were the market one of pure commodities, this would give a valid comparison. However, the energy being purchased often is not considered. The cost of any explosive should be considered in light of the work it can do, not the air it displaces or the price per pound. Consider in essence, the purchase of explosive energy as you would the sale of coal, in terms of dollars per Btu. Recent new developments in explosives technology make the economic ...
1987-03-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
