We report about the fabrication and analysis of the properties of Cr/CrO_x/Cr tunnel junctions and SET transistors, prepared by different variants of direct-writing multilayer technique. In all cases, the CrO_x tunnel barriers were formed in air under ambient conditions. From the experiments on single junctions, values for the effective barrier height and thickness were derived. For the Cr/CrO_x/Cr SET transistors we achieved minimal junction areas of 17 x 60 nm^2 using a scanning transmission electron microscope for the e-beam exposure on Si_3N_4 membrane substrate. We discuss the electrical performance of the transistor samples as well as their noise behavior.
1999-01-01
Scanning tip microwave near-field microscope
Energy Technology Data Exchange (ETDEWEB)
A near-field microscope which operates in the rf/microwave frequency range is described. In this microscope, a scanning tunneling microscope (STM)-like tip rather than an aperture is used as a point-like evanescent field emitter. A spatial resolution of {approximately}5 {mu}m ({approximately}{lambda}/100000) is achieved in the current version. The design of the microscope as well as the principal factors which affect its performance are discussed. {copyright} {ital 1996 American Institute of Physics.}
1996-06-01
In situ scanning tunneling microscope study of the passivation of Cu(111)
Energy Technology Data Exchange (ETDEWEB)
In situ scanning tunneling microscopy has been used to study the nucleation and growth mechanisms and the structure of passive films formed on Cu(111) surfaces in 0.1 M borate buffer solution (pH 9.3). A surface topography characterized by terraces with monoatomic steps is obtained after potentiodynamic reduction down to {minus}1.12 V/standard hydrogen electrode (SHE), of the electropolished surface exposed to air. The formation of a single Cu{sub 2}O passive layer at 0.03 V/SHE proceeds first by a roughening of the steps assigned to a locally blocked step flow process due to a competition between dissolution and preferential nucleation of the oxide at the steps. The observed oxide nuclei are 2--3 nm wide and about one atomic plane high. This process leads to the complete coverage of the terraces by a grain-like structure of the oxide film. The initial terrace topography is completely altered. Thickening of this oxide layer leads to unstable ...
1999-02-01
Observation of 77 K staircase I-V characteristics in 2DEG's irradiated by a focused ion beam
International Nuclear Information System (INIS)
Staircase current-voltage (I-V) characteristics, observed at 77 K in narrow 2DEG channels irradiated by a single line scan of a focused ion beam (FIB), is reported in detail. These staircases are interpreted as evidence of single electron tunneling through a naturally occurring specific Coulomb island in the random potential fluctuations created by FIB damage. Clear comparison is made between the I-V's taken from wide channels and those from narrow channels. Based on orthodox calculations of the I-V characteristics, it is shown that highly asymmetric tunnel junctions are needed to explain our data. This is consistent with the random nature of the potential landscape in the FIB damaged region. (author).
Dynamics of ligand substitution in labile cobalt complexes resolved by ultrafast T-jump
UK PubMed Central (United Kingdom)
Ligand exchange of hydrated metal complexes is common in chemical and biological systems. Using the ultrafast T-jump, we examined this process, specifically the transformation of aqua cobalt (II) complexes...Full Text Available
2008-09-02
Energy Technology Data Exchange (ETDEWEB)
A comprehensive Scanning Tunneling Microscopy (STM) study of submonolayer nucleation and growth of 2D islands in Ag/Ag(100) homoepitaxy for temperature between 295K and 370K is presented. The initial stages of multilayer kinetic roughening is also studied. Analysis of an appropriate model for metal (100) homoepitaxy, produces estimates of 350 meV for the terrace diffusion barrier, 400 meV for the adatom bond energy, and 25 meV for the additional Ehrlich-Schwoebel step-edge barrier.
1996-08-01
Etching characteristics of high-purity aluminum in hydrochloric acid solutions
Energy Technology Data Exchange (ETDEWEB)
We investigated the effects of additives to the etching solution of 1 M hydrochloric acid on the electrochemical etching behavior for aluminum electrolytic capacitors, using scanning and transmission electron microscopy, and AC impedance spectroscopy. For the addition of 1 M sulfuric acid or 5% ethylene glycol to the hydrochloric acid solution, the distribution of etch tunnels was more uniform with high density of etch pits compared with that without addition. The highest specific surface area was obtained from the electrolyte with 5% ethylene glycol additive. The correlation of internal morphologies of etched foils with impedance parameters was interpreted by impedance techniques.
2007-03-25
International Nuclear Information System (INIS)
Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary ...
1999-05-01
Tunnel Sensors Equipment on Environmental Expert
... Tunnel Sensors Equipment on Environmental Expert Find and compare a variety of tunnel sensors equipment on the world's largest environmental industry portal. View ...
A cost-utility analysis of open and endoscopic carpal tunnel release
UK PubMed Central (United Kingdom)
BACKGROUNDOpen carpal tunnel release (OCTR) is the standard procedure for the surgical treatment of carpal tunnel syndrome. With the advent of minimally invasive surgery, endoscopic...Full Text Available
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
The structure of hydroxylated oxide films (passive films) formed on Cr(110) in 0.5 M H{sub 2}SO{sub 4} at +0.35, +0.55, and +0.75 V/SHE has been investigated by in situ scanning tunneling microscopy (STM). Cathodic reduction pretreatments at {minus}0.54, {minus}0.64, and {minus}0.74 V/SHE destroy the well-defined topography of the single-crystal electrode and they have been excluded from the passivation procedure. Two different passive film structures have been observed, depending on the potential and time of passivation. At low potential (+0.35 V/SHE), the passive film, consisting mostly of chromium hydroxide, has a noncrystalline and granular structure whose roughness suggests local variations of thickness of ca. {+-} 0.5 nm. A similar structure is observed at higher potential (+0.55 V/SHE), but only for a short polarization time. For longer polarization at 0.55 V/SHE, and at higher potentials (+0.75 V/SHE), a crystalline structure is formed; ...
1999-09-16
Corps' tunnel 'expands' understanding of Permafrost
...Corps' tunnel 'expands' understanding of Permafrost Program News Home Warfighter Support Installations Environment Water Resources Information Technology About Us Partnering Opportunities About Us ...News Releases Program News Corps' tunnel 'expands' understanding of Permafrost Corps' tunnel \\
Calculations relating to two experiments that demonstrate coherent control of preformed rubidium-85 molecules in a magneto-optical trap using ultrafast laser pulses are presented. In the first experiment, it is shown that pre-associated molecules in an incoherent mixture of states can be made to oscillate coherently using a single ultrafast pulse. A novel mechanism that can transfer molecular population to more deeply bound vibrational levels is used in the second. Optimal parameters of the control pulse are presented for the application of the mechanism to molecules in a magneto-optical trap. The calculations make use of an experimental determination of the initial state of molecules photoassociated by the trapping lasers in the magneto-optical trap and use shaped pulses consistent with a standard ultrafast laser system.
2009-01-01
Pd adsorption on Si(1 1 3) surface: STM and XPS study
Energy Technology Data Exchange (ETDEWEB)
Pd-induced surface structures on Si(1 1 3) have been studied by scanning tunneling microscopy (STM) and X-ray photoelectron spectroscopy (XPS). In the initial process of the Pd adsorption below 0.10 ML, Pd silicide (Pd{sub 2}Si) clusters are observed to form randomly on the surface. By increasing the Pd coverage to 0.10 ML, the clusters cover the entire surface, and an amorphous layer is formed. After annealing the Si(1 1 3)-Pd surface at 600 deg. C, various types of islands and chain protrusions appears. The agglomeration, coalescence and crystallization of these islands are observed by using high temperature (HT-) STM. It is also found by XPS that the islands correspond to Pd{sub 2}Si structure. On the basis of these results, evolution of Pd-induced structures at high temperatures is in detail discussed.
2008-09-30
Development of high-field STM for 18 T cryocooled superconducting magnet
International Nuclear Information System (INIS)
To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.
2009-02-01
On the Origins of the Weak Folding Cooperativity of a Designed ??? Ultrafast Protein FSD-1
UK PubMed Central (United Kingdom)
FSD-1, a designed small ultrafast folder with a ββα fold, has been actively studied in the last few years as a model system for studying protein folding mechanisms and for testing...Full Text Available
2010-11-01
Study of porous silicon morphologies for electron transport
International Nuclear Information System (INIS)
Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous silicon is still a ...
1993-05-17
Energy Technology Data Exchange (ETDEWEB)
The properties of polycrystalline (Ti, Al)N coatings deposited on non-nitrided, classically plasma-nitrided and low pressure plasma-nitrided AISI H11 steel samples were investigated. The plasma deposition and low pressure plasma nitriding were performed in a Z700-LH magnetron sputter ion plating unit, while a separate unit was used for plasma nitriding of specimens at a pressure of several millibars. The (Ti, Al)N coating was deposited onto all the samples using the same equipment as for the plasma deposition and low pressure plasma nitriding. For the characterization of the composite structures, the following methods were used: scratch test, X-ray diffraction analysis, scanning electron microscopy, scanning tunnelling microscopy and microhardness testing. It was found that plasma nitriding prior to coating deposition strongly affects the growth and properties of hard coatings, such as the microhardness, adhesion, preferred ...
1993-05-15
Published ... - Wind Tunnels | NASA Ames Research Center - NASA
Sep 5, 2008 ... Russia. The six-component balance for blunt models aerodynamic force measurement in shock tunnel. Lu Zhiquo, Liu Hongshan, Zhang Yan ...
Iterated splitting and the Tunnel Classification Conjecture
For a genus-1 1-bridge knot in the 3-sphere, that is, a (1,1)-knot, a middle tunnel is a tunnel that is not an upper or lower tunnel for some (1,1)-position. Most torus knots have a middle tunnel, and non-torus-knot examples were obtained by Goda, Hayashi, and Ishihara. In a previous paper, we generalized their construction and calculated the slope invariants for the resulting examples. We give an interated version of the construction that produces many more examples, and calculate their slope invariants. If one starts with the trivial knot, the iterated construction produces the 2-bridge knots, giving a new calculation of the slope invariants of their tunnels. Together with other information, the examples suggest a general classification conjecture for all tunnels of all tunnel number 1 knots.
2011-01-01
Cost effective use of liquid nitrogen in cryogenic wind tunnels
A method of reliquefying from 12 to 19% of the nitrogen exhaust gas from a cryogenic wind tunnel has
1987-01-01
Ultrafast resonance energy transfer in bio-molecular systems
British Library Electronic Table of Contents (United Kingdom)
In this article, we present our consistent efforts to explore the dynamical pathways of the migration of electronic radiation by using ultrafast (picosecond/femtosecond time scales) F?rster resonance energy transfer (FRET) technique. The ultrafast non-radiative energy migration from an intrinsic donor fluorophore (Tryptophan, Trp214) present in domain IIA of a transporter protein human serum albumin (HSA) to various non-covalently/covalently attached organic/inorganic chromophores including photoporphyrin IX (PPIX), polyoxovanadate [V15As6O42(H2O)]-6 clusters (denoted as V15) and CdS quantum dots (QDs) has been explored. We have also used other covalently/non-covalently attached extrinsic fluorogenic donors (NPA, ANS) in order to exploit the dynamics of resonance energy migration of an enz...
2010-01-01
Ultrafast nonlinear optical response of Ag nanoparticles embedded in mesoporous thin films
British Library Electronic Table of Contents (United Kingdom)
Highly dispersed silver nanoparticles embedded in mesoporous thin films (MTFs) have been synthesized by modification of the interior surface of mesoporous silica with ethylenediamine moieties, which provided the coordination sites for the Ag ions, and subsequent reduction under hydrogen atmosphere. TEM observations show the mesoporous parent films have effectively controlled the growth of the synthesized silver nanoparticles. The composite films had an ultrafast nonlinear response time, as fast as 200 fs, and a third-order nonlinear optical susceptibility of 0.94??10?10 esu, which was enhanced by the local field enhancement effect that was present when the silver nanoparticles were embedded in the surrounding dielectric matrix. The origin of the ultrafast nonlinear response and the enhanc...
2009-01-01
Free-electron laser driven by the LBNL laser-plasma accelerator
Energy Technology Data Exchange (ETDEWEB)
A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.
2008-08-04
Ultrafast laser fabrication of submicrometer pores in borosilicate glass
UK PubMed Central (United Kingdom)
We demonstrate rapid fabrication of submicrometer-diameter pores in borosilicate glass using femtosecond laser machining and subsequent wet-etch techniques. This approach allows direct and repeatable...Full Text Available
2008-05-15
Energy Technology Data Exchange (ETDEWEB)
The motivation, feasibility and potential for two unconventional collider concepts - the Gamma-Gamma Collider and the Muon Collider - are described. The importance of the development of associated technologies such as high average power, high repetition rate lasers and ultrafast phase-space techniques are outlined.
1994-11-01
Acoustic tunneling through artificial structures: From phononic crystals to acoustic metamaterials
British Library Electronic Table of Contents (United Kingdom)
We present a comparative study on the acoustic tunneling through artificial periodical composites, from phononic crystals to acoustic metamaterials. We find that the features of the acoustic tunneling are closely related with the origins of band gaps. In particular, the band gap associated with the negative effective material parameter in the metamaterial results in a better analog of the tunneling effect to the quantum system.
2011-01-01
The dissolution of Ag(111) electrodes investigated by in situ scanning tunnelling microscopy
voltammetric methods. This remained evident for varying extents of silver dissolution. Ag(111) electrodes were oxidised in 0.1 M KCIO sub 4 solutions by a single swept ORC of 0.77x10 sup - sup 3 C cm sup - sup 2. The final rest potential of the Ag(111) working electrode was over the potential range of -36 mV to 114 mV versus the SCE where the silver islands of the reformed surface are believed to be unstable. Results show that a majority of silver islands of all sizes are stable with time, whereas the silver islands with irregular shapes tended to evolve to exhibit higher degrees of spherical geometry. Additionally, the position of the silver islands did not remain constant during the acquisition of STM images. Results from in situ STM demonstrated that the underlying step-terrace morphology of the Ag(111) electrodes did not remain constant with time. Both macroscale and nanoscale changes to the Ag(111) electrode surface were observed. It is concluded that this is due to the transport ...
1998-01-01
Optical and electronic properties of Ag nanodots on Si(111)
International Nuclear Information System (INIS)
Reflectance anisotropy spectroscopy (RAS) has been used, together with scanning tunnelling spectroscopy (STS), to investigate the optical and electronic properties of nanodots formed by depositing Ag on the Si(111)-3 x 1-Ag surface. One-dimensional (1D) arrays of nanodots were grown on a single-domain (3 x 1)-Ag surface and the anisotropic optical response in the 0.5-5 eV range measured by RAS. Aligned, elongated Ag islands were also grown on this surface to compare their properties with those of the nanodots. STS of the Ag islands showed distinct metallic behaviour, whereas the nanodots revealed a bandgap of #approx#0.6 eV, indicating that the surface of the dots has a non-metallic character, similar to that of the Si(111)-3 x 1-Ag surface. RAS also showed substantial differences between the structures, with a large infrared anisotropy for the metallic Ag islands consistent with anisotropic Drude-like intraband transitions, whereas the ...
2006-08-02
Energy Technology Data Exchange (ETDEWEB)
Nano-wire arrays of Niobium were produced by small angle sputtering on facetted sapphire, using the self shadowing effect of the facets. A wire width of about 80 nm was adjusted, the mean (maximum) wire height was about 20 nm (30 nm), the length can be in the cm range. Meander-film morphologies of 20 nm mean (26 nm maximum) thickness were produced by conventional sputtering onto smooth sapphire substrates at elevated temperatures. The morphology of the wires was investigated with atomic force microscopy (AFM), using contact mode. Meander-films were studied by scanning tunnelling microscopy (STM). Hydrogen loading was performed by instantaneously increasing the hydrogen gas pressure above the solubility limit. Thus, an elongated hydride could be monitored in an about 30 nm thick wire. STM studies on meander-films show the presence of cylindrical hydrides. Local out-of-plane and in-plane expansion can be explained by the formation of hydrides, ...
2007-10-31
Study on construction technology for repository
Energy Technology Data Exchange (ETDEWEB)
For the construction of underground facilities comprising access tunnels, connecting tunnels, main tunnels and disposal tunnels, a large number of tunnels will be excavated in deep rock formations. These excavations will extend hundreds kilometers in total length. Therefore, special attention must be paid, to transporting large volume of debris, ventilation, emergency escape routes in case of accident, and other factors. In addition, special attention must also paid to potential accidents which might in underground excavations, including unstable facing phenomena (such as collapse and swelling of facing at weak layer sections), spring water flow resulting collapse of rock, gas eruption, and rock burst. While considering these factors to be emphasized during the construction of geological disposal facilities, the investigation reviewed the existing working methods on individual ...
1999-11-01
Study on construction technology for repository
International Nuclear Information System (INIS)
For the construction of underground facilities comprising access tunnels, connecting tunnels, main tunnels and disposal tunnels, a large number of tunnels will be excavated in deep rock formations. These excavations will extend hundreds kilometers in total length. Therefore, special attention must be paid, to transporting large volume of debris, ventilation, emergency escape routes in case of accident, and other factors. In addition, special attention must also paid to potential accidents which might in underground excavations, including unstable facing phenomena (such as collapse and swelling of facing at weak layer sections), spring water flow resulting collapse of rock, gas eruption, and rock burst. While considering these factors to be emphasized during the construction of geological disposal facilities, the investigation reviewed the existing working methods on individual ...
1999-01-01
International Nuclear Information System (INIS)
The effects of intradot electron-electron interaction on the photon-assisted Andreev tunneling of a superconductor/carbon-nanotube/superconductor system are studied by using nonequilibrium Green's function technique. The inverse supercurrent reflecting the #pi#-junction transition emerges in the spin-split energy-levels regime polarized by the Coulomb interaction. For the positive tunneling case, the supercurrent reaches its maximum when the spin-degenerate energy-levels are nearest to the Fermi surface. Conversely, for the negative tunneling case, the supercurrent reaches its maximum when two split energy-levels are symmetric with respect of the Fermi surface. The sign and the amplitude of the Andreev tunneling depend distinctly on the energy-level spacing tuned by photon-assisted tunneling. In order to fully understand the transport characteristics, the current-carrying density of ...
2007-01-01
Effects of inorganic cation templates on octahedral molecular sieves of manganese oxide
Five hydrated inorganic divalent cations, Mg[sup 2+], Co[sup 2+], Ni[sup 2+], Cu[sup 2+], and Zn[sup 2+], have successfully been used as templates for the synthesis of manganese oxide octahedral molecular sieves (OMS-1) having the todorokite structure. The OMS-1 samples have been well characterized by X-ray diffraction, differential scanning calorimetry, thermogravimetric analysis, scanning electron microscopy/energy dispersive X-ray studies, inductively coupled plasma analysis, electron paramagnetic resonance, Fourier transform infrared spectroscopy, thiosulfate titration, and cyclohexane sorption. Catalytic CO oxidation and 2-propanol decomposition were carried out. Results show that these OMS-1 samples with a tunnel size of about 6.9 angstroms are crystalline and chemically pure. They have the following formulas: Mg[sub 3.17]Mn[sub 5.05]O[sub 12] [center dot] 4.52H[sub 2]O, Co[sub 1.84]Mn[sub 5.59]O[sub 12] [center dot] ...
1994-11-30
Carpal Tunnel Syndrome and Peripheral Polyneuropathy in Patients with End Stage Kidney Disease
UK PubMed Central (United Kingdom)
This study was designed to identify the causes of the development of carpal tunnel syndrome (CTS) associated with end stage kidney disease (ESKD). A total of 112 patients with ESKD, 64 on hemodialysis...Full Text Available
2011-09-01
A TUNNEL DIODE UNIVIBRATOR AND PULSE HEIGHT DISCRIMINATOR
A univibrator and a pulse height discriminator using tunnel diodes and backward diodes are described, along with their applications in pulse shaping and fast coincidence technique. The main advantages achieved are simplicity of design and speed. The characteristics of the two diodes are shown. (auth)
1961-03-01
Superconducting properties of metallic superlattices
Energy Technology Data Exchange (ETDEWEB)
The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
A new method for determining the energy gap of a superconductor using the maximum in the differential conductance curve of electron tunneling spectrum is given in this paper. The V/sub max//kT versus ..delta../kT curve was calculated from tunneling theory. V/sub max/, the voltage of the conductance maximum, can be measured from electron tunneling spectrum. ..delta../kT can be found from this curve, then the energy gap ..delta.. can be calculated. This method is simple, fast and accurate. The accuracy almost approaches that of the curve fitting method.
1986-02-01
... central venous catheters (tunneled [eg, Hickman], subcutaneously implanted [eg, Porta-cath], and nontunneled), peripherally inserted central venous catheters ...
Scanning Electron Microscope Examination of Cotton Linters ...
... TECHNICAL REPORT ARBRL-TR-02476 SCANNING ELECTRON MICROSCOPE ... SCANNING ELECTRON MICROSCOPE EXAMINATION OF ...
1983-03-01
Modeling Transient Discharge into a Tunnel Drilled in a Heterogeneous Formation
British Library Electronic Table of Contents (United Kingdom)
Abstract An analytical model is developed to predict transient discharge flow into a tunnel drilled at various speeds through a heterogeneous formation. This model relies on simplifying assumptions commonly enforced in hydrogeologic engineering, and combines the convolution and superposition principles to account for composite sections with arbitrary parametric contrasts. An application to the data monitored during the exploratory drilling of an Alpine tunnel confirms the validity of the approach.
2007-01-01
Ultrafast fluorescence dynamics of Sybr Green I/DNA complexes
British Library Electronic Table of Contents (United Kingdom)
The ultrafast dynamics of the DNA fluorescent dye Sybr Green I (SG) has been studied in buffer, single-stranded (ssDNA), double-stranded (dsDNA) and triple-stranded DNA (tsDNA). The fluorescence quantum yield of SG increases dramatically when bound to DNA (including tsDNA). The fluorescence dynamics of the free SG has shown two decay components with 0.15-0.4ps and 1.3-2.1ps time constants, depending on the fluorescence wavelength. Upon binding to DNA, the dynamics becomes slower exhibiting four decay components. This is mainly due to the restriction of the internal motions of the dye caused by the relatively rigid environment of the dye complexed with DNA.
2010-01-01
Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems
Energy Technology Data Exchange (ETDEWEB)
We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.
2006-03-06
Energy Technology Data Exchange (ETDEWEB)
In attempting to detect and map out underground facilities, whether they be large-scale hardened deeply-buried targets (HDBT's) or small-scale tunnels for clandestine border or perimeter crossing, seismic imaging using reflections from the tunnel interface has been seen as one of the better ways to both detect and delineate tunnels from the surface. The large seismic impedance contrast at the tunnel/rock boundary should provide a strong, distinguishable seismic response, but in practice, such strong indicators are often lacking. One explanation for the lack of a good seismic reflection at such a strong contrast boundary is that the damage caused by the tunneling itself creates a zone of altered seismic properties that significantly changes the nature of this boundary. This report examines existing geomechanical data that define the extent of an excavation damage zone around ...
2010-11-01
Energy Technology Data Exchange (ETDEWEB)
In July 1997, a field inspection was carried out of parts of the tunnel system of the Tonstad hydroelectric power station, Norway. This report discusses the findings: (1) The main drift has a varying bottom covering of sediments, (2) The tunnel to Ousdal had on its downmost 2 km an almost unbroken and apparently stable armour layer along the walls and an unstable or incomplete armour layer in the middle, (3) The tunnel to Homstoel almost had no bottom layer, (3) Sediments in side inlets and niches are of two kinds: (a) masses added through side inlets, (b) fine sand and mud deposited by the main tunnel, (4) A few cases were observed of downfallen rocks and of peeled rock of about 1 m size. It looks as if the Homstoel tunnel may have been previously used for larger discharges than that from Ousdal and that the latter is now being used to the limit of what the previously established ...
1997-10-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the ...
1999-05-01
Photoinduced charge separation reactions form the basis for energy storage processes in both natural and artificial photosynthesis. Moreover, rapid reversible photoinduced electron transfer reactions are a class of photophysical phenomena that can be exploited to develop schemes for optical switching. Examples from each of these fields are discussed.
1992-01-01
XPS and STM study of passive films formed on Fe-22Cr(110) single-crystal surfaces
Energy Technology Data Exchange (ETDEWEB)
X-ray photoelectron spectroscopy and ex situ scanning tunneling microscopy measurements have been combined to investigate the thickness, the chemical composition, and the structure of passive films formed in 0.5 M H{sub 2}SO{sub 4} on Fe-22Cr(110). Aging under polarization at +500 mV/SHE causes a dehydration (anodic) reaction of the outer chromium hydroxide layer of the passive film. This anodic reaction results in a thickening of the inner mixed Cr(III) and Fe(III) oxide layer enriched in Cr{sub 2}O{sub 3}. It also causes a coalescence of the oxide nuclei of the passive film and a crystallization of the inner Cr{sub 2}O{sub 3}. It also causes a coalescence of the oxide nuclei of the passive film and a crystallization of the inner Cr{sub 2}O{sub 3} oxide layer in epitaxy with the substrate. The epitaxial relationship is {alpha}-Cr{sub 2}O{sub 3}(0001) {parallel} Fe-22Cr(110) with three different azimuthal orientations. Aging under polarization ...
1996-04-01
STM studies of CDWs in pure and doped transition metal chalcogenides
Energy Technology Data Exchange (ETDEWEB)
The effects of dilute impurity doping on charge-density wave (CDW) structures and gaps in NbSe{sub 3} 1T-TaS{sub 2} and 2H-NbSe{sub 2} have been studied by using a scanning tunneling microscope (STM) operating at 4.2 K. In Fe doped samples of NbSe{sub 3} the STM spectroscopy measurements indicate that the added impurities can significantly shift the CDW energy gaps. In NbSe{sub 3}, Fe reduces both CDW gaps by 25-30%, and produces changes in the conductance structure relative to the pure material. The images of Fe{sub 0.01}NbSe{sub 3} show that all three surface chains in the unit cell still carry a strong CDW modulation with no evident disorder. However, a change in the relative amplitudes of the high and low temperature CDWs is detected. The effects of Co and Ni impurities on the gaps in NbSe{sub 3} have also been studied. While Co increases both by 25-30%, Ni increases only the high temperature gap with the low temperature gap remaining ...
1992-12-01
International Nuclear Information System (INIS)
We studied the epitaxial growth of iron silicide (#epsilon#-FeSi,#beta#-FeSi_2, and #alpha#-FeSi_2) nanodots on Si (111) substrates by Fe deposition on Si nanodots on Si (111) substrates with ultrathin Si oxide films using reflection high-energy electron diffraction, scanning tunneling microscopy, and transmission electron microscope (TEM). We formed almost single phase iron silicide nanodots by controlling the Fe deposition conditions; growth temperature, deposition rate, and amount. The #epsilon#-FeSi or #alpha#-FeSi_2 nanodots were epitaxially grown in a dome shape with an average size of #approx#5 nm and an ultrahigh density (>10"1"2 cm"-"2) on the surface. We formed #approx#2-nm high and #approx#8-nm wide #beta#-FeSi_2 nanodots in a dome shape with a density of #approx#5x10"1"1 cm"-"2 on the surface. Cross-sectional TEM images revealed that the #beta#-FeSi_2 growth continued beneath the Si surface. The part of the #beta#-FeSi_2 nanodot ...
2005-08-15
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new method for the determination of the energy gap of superconductors. The V/sub max//kT versus ..delta../kT curve was calculated from tunneling theory. The maximum voltage in differential conductance V/sub max/ was measured from the electron tunneling spectrum. From V/sub max//kT and the curve, one can easily calculate the energy gap value ..delta... This method is simple, and the accuracy almost approaches that of the curve-fitting method.
1986-07-01
International Nuclear Information System (INIS)
This paper presents a new method for the determination of the energy gap of superconductors. The V/sub max//kT versus #DELTA#/kT curve was calculated from tunneling theory. The maximum voltage in differential conductance V/sub max/ was measured from the electron tunneling spectrum. From V/sub max//kT and the curve, one can easily calculate the energy gap value #DELTA#. This method is simple, and the accuracy almost approaches that of the curve-fitting method.
Wind Tunnel Flow Quality and Data Accuracy Requirements
... tests, one often encounters, for instance, separated flows with large ... It is suspected that the flow-quality criteria given in AGARD Report No. ...
1982-11-01
Tunneling spectra of high-temperature superconductors
International Nuclear Information System (INIS)
The frequency dependence of the tunneling spectrum #alpha#"2F (#omega#) is analyzed in terms of electron pairing induced by exchange of acoustic plasmons in addition to the usual phonon-exchange mechanism. Analytic expressions are obtained for the electron self-energy, the tunneling function #alpha#"2F, and the electron pairing coupling lambda which determines the superconducting properties. The resulting theory is applied to recent tunneling data of Nb_3Sn in order to examine the anomalous discrepancies with the phonon density of states found by neutron scattering experiments. The results demonstrate how the high-temperature (T/sub c/ approx. 20 "0K) superconducting properties of A-15 compounds are enhanced by acoustic-plasmon contributions, and thus they reconcile these high transition temperatures with the relatively small values of the phonon part of lambda estimated from several independent experiments.
Tunneling magnetoresistance from a symmetry filtering effect
International Nuclear Information System (INIS)
This paper provides a brief overview of the young, but rapidly growing field of spintronics. Its primary objective is to explain how as electrons tunnel through simple insulators such as MgO, wavefunctions of certain symmetries are preferentially transmitted. This symmetry filtering property can be converted into a spin-filtering property if the insulator is joined epitaxially to a ferromagnetic electrode with the same two-dimensional symmetry parallel to the interface. A second requirement of the ferromagnetic electrodes is that a wavefunction with the preferred symmetry exists in one of the two spin channels but not in the other. These requirements are satisfied for electrons traveling perpendicular to the interface for Fe-MgO-Fe tunnel barriers. This leads to a large change in the resistance when the magnetic moment of one of the electrodes is rotated relative to those of the other electrode. This large tunneling ...
2008-04-01
Tests of the ONERA Calibration Models in Three Transonic ...
... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...
1976-11-01
Shock Tunnel Studies of Scramjet Phenomena - NASA Technical Report ...
Kinetic reaction mechanisms have a hierarchical smacture with mechanisms for complex fuels built up on sub-mechanisms for simple fuel molecules ...
Sandia National Labs: PCNSC: Departments: Semiconductor Material...
For coupled quantum wires and dots, tunneling effects and coherent transport for quantum computing are being studied. In 2D systems, electron-hole bilayers for exciton...
2011-07-05
Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.
2007-01-01
Combined migration velocity model-building and its application in tunnel seismic prediction
We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an accurate prediction of the front of the ...
2010-09-01
Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes
... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...
Feb 13, 2005 ... Part 8 of a non-mathematical historical review of elementary quantum theory, to help explain processes in the Sun and in stars; part of an ...
Particle-Sizing System for Scanning Electron Microscope ...
... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...
1991-03-01
A bright field scanning transmission electron microscope (STEM ...
A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...
Ultrafast carrier dynamics of InGaAsN and InGaAs single quantum wells
International Nuclear Information System (INIS)
Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results reveal that the carrier dynamics is strongly affected by N ...
2008-04-21
Energy Technology Data Exchange (ETDEWEB)
This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements require a linear ...
2004-12-15
Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences
International Nuclear Information System (INIS)
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an ...
Wind tunnel modeling of heat islands in a turbulent boundary layer
International Nuclear Information System (INIS)
The basic studies of this report, had been done with a wind tunnel. Model similarity with typical atmospheric situations - such as an urban heat island - had to exist. Sufficient heat is needed to generate turbulent convection at the ground. By omitting the Boussinesq-approximation proper similarity parameters could be found to present the results in a dimensionless form. Also the effect of a cross circulation was investigated as well as the question at which conditions the convection is no longer able to overcome the longitudinal momentum of the wind. (KW).
Tunneling spectroscopy of anisotropic superconductors
Energy Technology Data Exchange (ETDEWEB)
Tunneling spectroscopy of normal-insulator-superconductor junction is investigated theoretically. In anisotropic superconductors, differently from the case of isotropic superconductor, the effective pair potentials felt by quasiparticles depend on the direction of their motion. By taking this effect into account, it is shown that the conductance spectra strongly depend on the crystal orientation. Using Green`s function method, local density of states (LDOS) in superconductor is also calculated. The close relation between conductance spectra and LDOS is presented. The calculation is compared with experimental spectra of high-{Tc} superconductors.
1996-12-31
Similarity between the primary and secondary air-assisted liquid jet breakup mechanism
we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.
2007-01-01
All Optical Switch of Vacuum Rabi Oscillations: The Ultrafast Quantum Eraser
We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.
2010-01-01
The Performance of Spent Fuel Casks in Severe Tunnel Fires
International Nuclear Information System (INIS)
The Nuclear Regulatory Commission (NRC), working with the National Institute of Standards and Technology (NIST), Pacific Northwest National Laboratory (PNNL), and the National Transportation Safety Board (NTSB), performed analyses to predict the response of various spent fuel transportation cask designs when exposed to a fire similar to that which occurred in the Howard Street railroad tunnel in downtown Baltimore, Maryland on July 18, 2001. The thermal performance of three different spent fuel cask designs (HOLTEC HI-STAR 100, TransNuclear TN-68, and NAC-LWT) was evaluated with the ANSYSR and COBRA-SFS analysis codes, utilizing boundary conditions for the tunnel fire obtained using NIST's Fire Dynamics Simulator (FDS) code. NRC Staff evaluated the potential for a release of radioactive material from each of the three transportation casks analyzed for the Baltimore tunnel fire scenario. The results of these analyses are ...
2005-11-01
Response of a Spent Fuel Transportation Cask to a Tunnel Fire Event
Energy Technology Data Exchange (ETDEWEB)
The staff of the Spent Fuel Project Office at the U.S. Nuclear Regulatory Commission undertook the investigation and thermal analysis of the Baltimore tunnel fire event. This event occurred in the Howard Street tunnel, in Baltimore, Maryland, on July 18, 2001. The staff was tasked with assessing the consequences of this event on the transportation of spent nuclear fuel. This paper describes the staff's coordination with the following government and laboratory organizations: the National Transportation Safety Board (NTSB), to determine the details of the train derailment and fire; the National Institute of Standards and Technology (NIST), to quantify the thermal conditions within the tunnel; the Center for Nuclear Waste Regulatory Analysis (CNWRA), to validate the NIST evaluations, and the Pacific Northwest National Laboratory (PNNL), to assist in the thermal analysis. The results of the staff's review and ...
2003-02-25
Effect of oxide treatment at the microcrystalline tunnel junction of a-Si:H/a-Si:H tandem cells
Energy Technology Data Exchange (ETDEWEB)
The electrical transport taking place in the {mu}c-Si tunnel recombination junction (TRJ) of a-Si:H/a-Si:H tandem solar cells and the role of CO{sub 2} plasma oxidation performed between microcrystalline layers is investigated in this paper with the computer code AMPS. Oxidized interfaces were modelled as simple highly defective intrinsic {mu}c-Si layers. Two different tunnel junction structures are studied in this paper: (a) (n){mu}c-Si/oxide/(p){mu}c-Si and (b) (n){mu}c-Si/(i){mu}c-Si/(p){mu}c-Si. In the last configuration the oxide interface is removed and replaced by a thin defective (i) {mu}c-Si layer. Both tunnel junctions have comparable theoretical and experimental tandem solar cell efficiencies which indirectly proves that our modelling assumption for oxidised interfaces is correct. A-Si:H/a-Si:H tandem solar cell efficiencies depend on the thickness of the intrinsic layer introduced in the ...
2000-05-01
Wind tunnel and numerical study of a small vertical axis wind turbine
British Library Electronic Table of Contents (United Kingdom)
This paper presents a combined experimental and computational study into the aerodynamics and performance of a small scale vertical axis wind turbine (VAWT). Wind tunnel tests were carried out to ascertain overall performance of the turbine and two- and three-dimensional unsteady computational fluid dynamics (CFD) models were generated to help understand the aerodynamics of this performance. Wind tunnel performance results are presented for cases of different wind velocity, tip-speed ratio and solidity as well as rotor blade surface finish. It is shown experimentally that the surface roughness on the turbine rotor blades has a significant effect on performance. Below a critical wind speed (Reynolds number of 30,000) the performance of the turbine is degraded by a smooth rotor surface finis...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...
2011-01-01
Silicon oxide conductivity of hydrogen ion implanted polysilicon thin film transistors
Energy Technology Data Exchange (ETDEWEB)
The influence of hydrogen ion implantation into the channel polysilicon of polysilicon thin film transistors on gate oxide conductivity has been investigated. Data for effective tunnelling barriers at the gate oxide/channel polysilicon interface are presented. A value of 1.2eV for samples with boron doped channel polysilicon is calculated. For hydrogenated boron doped samples tunnelling barriers higher than 2.1 eV are obtained. The tunnelling barriers for phosphorus doped samples are impurity concentration dependent and decrease with increasing phosphorus concentration in the range 3 x 10{sup 17} to 3 x 10{sup 19} cm{sup -3}. (Author).
1996-10-01
Silicon oxide conductivity of hydrogen ion implanted polysilicon thin film transistors
International Nuclear Information System (INIS)
The influence of hydrogen ion implantation into the channel polysilicon of polysilicon thin film transistors on gate oxide conductivity has been investigated. Data for effective tunnelling barriers at the gate oxide/channel polysilicon interface are presented. A value of 1.2eV for samples with boron doped channel polysilicon is calculated. For hydrogenated boron doped samples tunnelling barriers higher than 2.1 eV are obtained. The tunnelling barriers for phosphorus doped samples are impurity concentration dependent and decrease with increasing phosphorus concentration in the range 3 x 10"1"7 to 3 x 10"1"9 cm"-"3. (Author).
Offshore drilling rig with enclosed work area
Energy Technology Data Exchange (ETDEWEB)
In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.
1987-12-01
Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki
Energy Technology Data Exchange (ETDEWEB)
A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)
2000-01-10
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to investigate whether hydroxyapatite (HAp) coating could induce polyethylene terephthalate (PET) artificial ligament graft osseointegration in the bone tunnel. Twenty-four New Zealand white rabbits underwent artificial ligament graft transplantation in bilateral proximal tibia tunnels. One limb was implanted with HAp-coated PET graft, and the contralateral limb was implanted with non-HAp-coated PET graft as control. The rabbits were randomly sacrificed at four and eight?weeks after surgery. The loads to failure of the experimental group at eight?weeks were significantly higher than those of the control group (p?=?0.0057). Histologically, application of HAp coating induced new bone formation between graft and bone at eight?weeks compared with the controls. Rea...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In this paper, we discuss various aspects of the development of an inverted-grown AlGaAs/GaAs cascade solar cell incorporating a patterned germanium tunnel junction. Topics include the development of the Al{sub 0.37}Ga{sub 0.63}As top cell, the growth of the GaAs bottom cell over the patterned germanium tunnel junction, and a technique for selective removal of thin AlGaAs/GaAs heterostructures after lattice-matched growth on germanium substrates. The problems to be overcome for the achievement of around 30% efficiencies in the AlGaAs/GaAs cascade cell under concentrator applications are also discussed. (orig.).
1991-05-01
Jul 8, 2008 ... This case involves the flow over the ONERA M6 wing. ... The wind tunnel tests are documented by Schmitt and Charpin in the AGARD Report AR-138 ... supersonic flow, shocks, and turbulent boundary layers separation). ...
Novel Technique for Aerodynamic Force Measurement in Shock Tubes.
For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...
1989-01-01
Drama-based education to motivate participation in substance abuse prevention
UK PubMed Central (United Kingdom)
BackgroundThe substance abuse prevention goal of the theatre production "TUNNELS" was to provide community education on substance abuse to an audience in Durham, NC and surrounding...Full Text Available
Aerodynamic Force Characteristics of Bluff Bodies.
The lift and drag characteristics of a wide range of bluff body shapes were studied using data from sources including wind tunnel testing and flow visualization. For a given orientation of any body, it is found that its drag is strongly influenced by its ...
1985-01-01
Motion compensation with a scanned ion beam: a technical feasibility study
UK PubMed Central (United Kingdom)
BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target...Full Text Available
Los Alamos DP West Plutonium Facility decontamination project
Energy Technology Data Exchange (ETDEWEB)
The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation.
1982-01-01
LCLS XTOD Tunnel Vacuum System (XVTS)
Energy Technology Data Exchange (ETDEWEB)
The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.
2005-11-04
A study on the design method of multi tunnels in geological disposal facility
International Nuclear Information System (INIS)
In the geological disposal facility of the high-level radioactive waste, a group of galleries is designed in parallel at the depth of more than 300 m below surface. This is an unprecedented structure in the field of conventional engineering, and it is necessary to take this characteristic into consideration in the design of the galleries. In the geological disposal facility, as well as ensuring the dynamic stability of the gallery during construction and operational periods, it is necessary to evaluate the EDZ adequately for long-term stability after the closure. In this study, analysis of the 'multi tunnels model' which represents the whole gallery group was performed and the results about the outbreak behavior of EDZ were summarized. (author)
2008-01-01
Development of New Ground Inspection Techniques for the ...
Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...
Bone scanning in Ewing's sarcoma
International Nuclear Information System (INIS)
In eight patients with Ewing's sarcoma bone scans were performed using "9"9"mTc-MDP. This procedure rendered possible the diagnosis of clinically or radiologically silent metastases. (orig.).
This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to
2003-01-01
Single-event dynamics of high-performance HBTs and GaAs MESFETs
Energy Technology Data Exchange (ETDEWEB)
Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.
1993-12-01
...motion - Oxford Low carbon power - Imperial Oil exploration - Edinburgh Better policing - Leeds Efficient aircraft - Bristol Pioneering Drug Delivery - Nottingham Plastic electronics - Cambridge Materials discovery - Liverpool Bioluminescence - Cardiff Sucralose - King's Intellectual property - LSE Aeroengine repair - Birmingham Anti-viral drugs - UCL Marine engineering skills - Southampton Business Management - Warwick Medical imaging - Imperial Biopharmaceutical skills - Newcastle Primary education - Queen's Ultrafast Computing - Glasgow Clinical Development Centre - Kings Clean fuels at Oxford DNA sequencing - Cambridge 3G phone auctions - UCL Drugs and health screening - Leeds Business and Community Innovation Graduates Training and professional development Members Download a ...
Quantum coherence in ion channels: resonances, transport and verification
Energy Technology Data Exchange (ETDEWEB)
Recently it was demonstrated that long-lived quantum coherence exists during excitation energy transport in photosynthesis. It is a valid question up to which length, time and mass scales quantum coherence may extend, how one may detect this coherence and what, if any, role it plays in the dynamics of the system. Here we suggest that the selectivity filter of ion channels may exhibit quantum coherence, which might be relevant for the process of ion selectivity and conduction. We show that quantum resonances could provide an alternative approach to ultrafast two-dimensional (2D) spectroscopy to probe these quantum coherences. We demonstrate that the emergence of resonances in the conduction of ion channels that are modulated periodically by time-dependent external electric fields can serve as signatures of quantum coherence in such a system. Assessments of experimental feasibility and specific paths towards the experimental realization of such experiments are ...
2010-08-15
Energy Technology Data Exchange (ETDEWEB)
This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.
2003-09-10
High-resolution NMR on /sup 29/Si nuclei in acidic zeolites
The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.
1986-12-01
Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development
International Nuclear Information System (INIS)
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...
2002-08-01
Versatile gamma scanning system
International Nuclear Information System (INIS)
(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.
Is there still a place for bone scanning in Ewing's sarcoma: concise communication
International Nuclear Information System (INIS)
In this retrospective study, 28 cases of Ewing's sarcoma are reviewed for the onset of metastasis. Bone scans demonstrated bone metastasis in three out of 28 patients at presentation. Of the 22 patients free of metastases at presentation, ten subsequently developed bone metastases. In six of these patients, the bone scan was the earliest demonstrator of metastatic disease. Bone scans are recommended at presentation and periodically during follow-up.
... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...
Energy Technology Data Exchange (ETDEWEB)
Research highlights: {yields} The use of resonant photoemission in its 'core-hole clock' expression for the study of the dynamical charge transfer across hybrid organic-inorganic interfaces and for the intermolecular charge transfer in the bulk of organic thin films is reviewed. {yields} The electronic coupling to the substrate and the efficiency of charge transport across hybrid interfaces is different for individual electronic subsystems of the molecular adsorbate. {yields} The intermolecular charge transfer in the bulk of discotic liquid crystals occurs on the order of a few femtoseconds and is faster than expected from the macroscopic charge transport characteristics of the material. -- Abstract: The focus of this brief review is the use of resonant photoemission in its 'core-hole clock' expression for the study of two important problems relevant for the field of organic electronics: the dynamical charge transfer across hybrid organic-inorganic ...
2011-01-15
Energy Technology Data Exchange (ETDEWEB)
This thesis details the first direct ultrafast measurements of the dynamic thermal expansion of a surface and the temperature dependent surface thermal diffusivity using a two-color reflection transient grating technique. Studies were performed on p-type, n-type, and undoped GaAs(100) samples over a wide range of temperatures. By utilizing a 90 fs ultraviolet probe with visible excitation beams, the effects of interband saturation and carrier dynamics become negligible; thus lattice expansion due to heating and subsequent contraction caused by cooling provided the dominant influence on the probe. At room temperature a rise due to thermal expansion was observed, corresponding to a maximum net displacement of {approximately} 1 {Angstrom} at 32 ps. The diffracted signal was composed of two components, thermal expansion of the surface and heat flow away from the surface, thus allowing a determination of the rate of expansion as well as the surface thermal diffusivity, ...
1992-04-01
Spent fuel transportation cask response to a tunnel fire scenario
Energy Technology Data Exchange (ETDEWEB)
On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB), the U.S. agency responsible for determining the cause of transportation accidents, to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for Nuclear Waste Regulatory ...
2004-07-01
Normal-state conductance used to probe superconducting tunnel junctions for quantum computing
International Nuclear Information System (INIS)
Here we report normal-state conductance measurements of three different types of superconducting tunnel junctions that are being used or proposed for quantum computing applications: p-Al/a-AlO/p-Al, e-Re/e-AlO/p-Al, and e-V/e-MgO/p-V, where p stands for polycrystalline, e for epitaxial, and a for amorphous. All three junctions exhibited significant deviations from the parabolic behavior predicted by the WKB approximation models. In the p-Al/a-AlO/p-Al junction, we observed enhancement of tunneling conductances at voltages matching harmonics of Al-O stretching modes. On the other hand, such Al-O vibration modes were missing in the epitaxial e-Re/e-AlO/p-Al junction. This suggests that absence or existence of the Al-O stretching mode might be related to the crystallinity of the AlO tunnel barrier and the interface between the electrode and the barrier. In the e-V/e-MgO/p-V junction, which is one of the candidate systems for ...
2010-04-01
Quantum Transition State Theory for proton transfer reactions in enzymes
We consider the role of quantum effects in the transfer of hyrogen-like species in enzyme-catalysed reactions. This study is stimulated by claims that the observed magnitude and temperature dependence of kinetic isotope effects imply that quantum tunneling below the energy barrier associated with the transition state significantly enhances the reaction rate in many enzymes. We use a path integral approach which provides a general framework to understand tunneling in a quantum system which interacts with an environment at non-zero temperature. Here the quantum system is the active site of the enzyme and the environment is the surrounding protein and water. Tunneling well below the barrier only occurs for temperatures less than a temperature $T_0$ which is determined by the curvature of potential energy surface near the top of the barrier. We argue that for most enzymes this temperature is less than room temperature. For ...
2009-01-01
Photoelectrochemistry of disordered passive films
Energy Technology Data Exchange (ETDEWEB)
A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes ...
1987-01-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...
2006-04-01
Spent Fuel Transportation Package Response to the Baltimore Tunnel Fire Scenario
International Nuclear Information System (INIS)
On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB, the U.S. agency responsible for determining the cause of transportation accidents), to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for Nuclear Waste Regulatory ...
2006-11-01
Theory of NMR multiple echoes in solid hydrogen
Energy Technology Data Exchange (ETDEWEB)
We have examined the theory of NMR multiple echoes developed for solid {sup 3}He to determine whether multiple echoes could be observed in solid hydrogen. We were particularly interested in the possibility of testing for low frequency quantum tunneling motions in solid hydrogen by the observation of multiple echoes. We find that for easily accessible nuclear spin polarizations, P > 12%, multiple echoes would be observed for HD impurities in solid parahydrogen if motional narrowing is effective in increasing the HD nuclear spin-spin relaxation time T{sub 2} to the order of 1 msec. These values for T{sub 2}, which have been observed for HD impurity concentrations of the order of 1%, are larger than the calculated rigid lattice values and can be attributed to quantum tunneling at frequencies of the order of 1kHz.
1995-11-01
Pinned fluxons in a Josephson junction with a finite-length inhomogeneity
We consider a Josephson junction system installed with a finite length inhomogeneity, either of microresistor or of microresonator type. The system can be modelled by a sine-Gordon equation with a piecewise-constant function to represent the varying Josephson tunneling critical current. The existence of pinned fluxons depends on the length of the inhomogeneity, the variation in the Josephson tunneling critical current and the applied bias current. We establish that a system may either not be able to sustain a pinned fluxon, or - for instance by varying the length of the inhomogeneity - may exhibit various different types of pinned fluxons. Our stability analysis shows that changes of stability can only occur at critical points of the length of the inhomogeneity as a function of the (Hamiltonian) energy density inside the inhomogeneity - a relation we determine explicitly. In combination with continuation arguments and Sturm-Liouville theory, we ...
2011-01-01
On virtual phonons, photons and electrons
A macroscopic realization of the strange virtual particles is presented. The classical Helmholtz and the quantum mechanical Schr\\"odinger equations are analogous differential equations. Their imaginary solutions are called evanescent modes in the case of elastic and electromagnetic fields. In the case of non-relativistic quantum mechanical fields they are called tunneling solutions. The imaginary solutions of this differential equation point to strange consequences: They are non local, they are not observable, and they described as virtual particles. During the last two decades QED calculations of the imaginary solutions have been experimentally confirmed for phonons, photons, and for electrons. The experimental proofs of the predictions of the non-relativistic quantum mechanics and of the Wigner phase time approach for the elastic, the electromagnetic and the Schr\\"odinger fields will be presented in this article. The results are zero ...
2009-01-01
Extracorporeal Shock Wave Therapy in Pillar Pain After Carpal Tunnel Release: A Preliminary Study
British Library Electronic Table of Contents (United Kingdom)
"Pillar pain" is a relatively frequent complication after surgical release of the median nerve at the wrist. Its etiology still remains unknown although several studies highlight a neurogenic inflammation as a possible cause. Pillar pain treatment usually includes rest, bracing and physiotherapy, although a significant number of patients still complain of painful symptoms two or even three years after surgery. The aim of this study was to investigate the efficacy of low-energy, flux density-focused extracorporeal shock wave therapy (ESWT) in the treatment of pillar pain. We treated 40 consecutive patients with ESWT who had pillar pain for at least six months after carpal tunnel release surgery, and to our knowledge, this is the first study that describes the use of ESWT for treating this c...
2011-01-01
"9"9"mTechnetium-heat damaged erythrocyte spleen scan
International Nuclear Information System (INIS)
"9"9"mTechnetium -heat damaged erythrocyte were used as spleen scanning agents in 12 patients from July, 1985 to April, 1986. We used this scan to evaluate situs inversus, asplenia, accessory spleen, hypersplenism, splenic infarction, tumor staging and evaluation of therapy, especially when the "9"9"mTc-tin colloid scans were not definite for diagnosis. The techniques applied to these scans were in vivo/in vitro-labeling method and heating-method to damage the erythrocytes. Liver-to-spleen uptake ratios were increased upto 100:1 and interference from the left lobe of the liver was eliminated. These scans were helpful to evaluate the spleen. (Author).
Ultrasmall spot size scanning laser ophthalmoscopy
UK PubMed Central (United Kingdom)
An ultrasmall spot size scanning laser ophthalmoscope has been developed that employs an annular aberration-corrected incident beam to increase the effective numerical aperture of the eye thereby reducing...Full Text Available
Simple device for scanning image
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
2002-01-01
Role of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot
UK PubMed Central (United Kingdom)
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
2010-02-01
UK PubMed Central (United Kingdom)
Background:The purpose of the study was to evaluate vitreoretinal interface (VRI) alteration with a short-wavelength scanning laser ophthalmoscope (swSLO), the Nidek F-10, and compare...Full Text Available
2011-01-01
New Biomarkers Probing Depth of Cell Senescence Assessed by Laser Scanning Cytometry
UK PubMed Central (United Kingdom)
The imaging analytical capabilities of laser scanning cytometer (LSC) have been used to assess morphological features considered to be typical of the senescent phenotype. The characteristic “flattening”...Full Text Available
2010-11-01
Reactor poolside high-resolution fuel rod gamma scanning system
International Nuclear Information System (INIS)
(1981). United States Blair, TR Exxon Nucl, Richland, WA 99352
Energy Technology Data Exchange (ETDEWEB)
Thirty-two patients with AIDS related complex (ARC) or acquired immunodeficiency syndrome (AIDS) underwent /sup 67/Ga scans as part of their evaluation. Three patterns of /sup 67/Ga biodistribution were found: lymph node uptake alone; diffuse pulmonary uptake; normal scan. Gallium-67 scans were useful in identifying clinically occult Pneumocystis carinii pneumonia in seven of 15 patients with ARC who were asymptomatic and had normal chest radiographs. Gallium scans are a useful ancillary procedure in the evaluation of patients with ARC or AIDS.
1987-07-01
Environmental scanning electron microscopy
Energy Technology Data Exchange (ETDEWEB)
The ElectroScan environmental scanning electron microscope (ESEM) is one of the most exciting new developments in the field of Electron Microscopy. The ESEM differs from conventional Scanning Electron Microscopes (SEM) by being able to examine materials including liquids and oils in their natural state with no prior sample preparation. Accessory equipment, cooling, heating and manipulating devices allow the manipulation of samples thus making it possible for the first time to image dynamic processes such as wetting, drying, absorption, corrosion, melting, crystallisation, curing and fracturing at high magnification. Papers concerning the historical development of the ESEM are given in a bibliography at the end of this paper. 24 refs., 18 figs.
1994-12-31
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
Time-resolved resonance and linewidth of an ultrafast switched GaAs/AlAs microcavity
We explore a planar GaAs/AlAs photonic microcavity using pump-probe spectroscopy. Free carriers are excited in the GaAs with short pump pulses. The time-resolved reflectivity is spectrally resolved short probe pulses. We show experimentally that the cavity resonance and its width depend on the dynamic refractive index of both the lambda-slab and the lambda/4 GaAs mirrors. We clearly observe a double exponential relaxation of both the the cavity resonance and its width, which is due to the different recombination timescales in the lambda-slab and the mirrors. In particular, the relaxation time due to the GaAs mirrors approaches the photon storage time of the cavity, a regime for which nonlinear effects have been predicted. The strongly non-single exponential behavior of the resonance and the width is in excellent agreement to a transfer-matrix model taking into account two recombination times. The change in width leads to a change in reflectivity modulation depth. The model predicts an ...
2009-01-01
Improving T D reliability. How pumped storage can boost network security
Energy Technology Data Exchange (ETDEWEB)
The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, provides 5000 acre-ft of active storage volume ...
1994-03-01
High-performance hybrid pervaporation membranes with superior hydrothermal and acid stability
Energy Technology Data Exchange (ETDEWEB)
A new organic-inorganic hybrid membrane has been prepared with exceptional performance in dewatering applications. The only precursor used in the sol-gel synthesis of the selective layer was organically linked 1,2-bis(triethoxysilyl)ethane (BTESE). The microporous structure of this layer enables selective molecular sieving of small molecules from larger ones. In the dehydration of n-butanol with 5% of water, the membrane shows a high separation factor of over 4000 and ultra-fast water transport at a rate of more than 20 kg m{sup -2} h{sup -1} at 150C. This can be related to the high adsorption capacity of the material and the sub-micron thickness of the selective layer. The selectivity has now remained constant over almost one and a half years under continuous process testing conditions. Apart from the hydrothermal stability, the membrane exhibits a high tolerance for acid contamination. A slow performance decline in flux and separation factor is only observed at a ...
2009-05-15
The model was based on a SEDCO 700 series semi-submersible offshore drilling rig used for operations in the North Sea. This report supplements earlier work on wind-heeling moments which are required to establish stability criteria on semi-submersibles. Wi...
1982-01-01
Wind-tunnel measurements were taken of the time-average aerodynamic forces and moments on a notional model of a semi-submersible offshore drilling rig at two heights and at various attitudes to the wind. Attempts were made to analyze the separate effects ...
1982-01-01
Tailored airfoils for vertical axis wind turbines
Energy Technology Data Exchange (ETDEWEB)
The evolution of a family of airfoil sections designed to be used as blade elements of a vertical axis wind turbine (VAWT) is described. This evolution consists of extensive computer simulation, wind tunnel testing and field testing. The process reveals that significant reductions in system costs-of-energy and increases in fatigue lifetime may be expected for VAWT systems using these blade elements.
1984-11-01
Energy Technology Data Exchange (ETDEWEB)
The wavefunction of a particle extends into the classically forbidden barrier region of the potential energy surface. The consequence of this partial delocalisation is the phenomenon of quantum tunnelling, an effect which enables a particle to penetrate a potential barrier of magnitude greater than the energy of the particle. The tunnelling probability is an exponential function of the particle mass. The effect is therefore an important contribution to the behaviour of light atoms, in particular the proton. The hydrogen bond has long been appreciated to be an essential component of many biological and chemical systems, and the proton transfer reaction in the hydrogen bond is fundamental to many of these processes. The proton behaviour in the hydrogen bonds of benzoic acid, acetylacetone and calix-4-arene has been studied. A variety of techniques, both experimental and computational, were adopted for the study of the three hydrogen bonded ...
2002-07-01
Progress of magnetic-suspension systems and magnetic bearings in the USSR
International Nuclear Information System (INIS)
This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.
1992-05-01
Proceedings, international symposium on mine mechanization and automation
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under the session headings: research in mechanical fragmentation; rock characterization, remote sensing and interface detection; monitoring, data transmission and communications; tunnel boring machines; minewide monitoring and expert systems for ground control; machine guidance; shaft and raise boring; automation of drilling equipment; machine automation and control; new developments in mechanical miners; materials handling; innovative mining systems; general minewide monitoring and expert systems; ground support; human factors; and extraterrestrial mining.
1991-01-01
Nel tunnel alla ricerca di una nuova fisica
The Large Hadron Collider is at the top of world-wide science for particle physics. It promises to open the road to a new knowledge of the universe and its nature. Luciano Maiani and Robert Aymar, actual and future Director Generals of CERN, explain the aims of this most powerful instrument, the difficulties and the industrial repercussions, among which will be the "Grid", that will change the telecommunications (4 pages)
2003-01-01
Jet cutting and cleaning bibliography
Energy Technology Data Exchange (ETDEWEB)
This bibliography includes over 600 references (with abstracts) on all aspects of waterjet cutting and cleaning. The references are listed under the following chapter headings: fluid mechanics of jets; jet impact; equipment; jet cleaning; jet cutting; civil engineering; mining and tunnelling; precision cutting; underwater; safety; and bibliographies. Separate author and corporate source indexes are provided.
1988-01-01
International Symposium on Magnetic Suspension Technology. Part 2
International Nuclear Information System (INIS)
In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.
1991-08-19
Two-dimensional generalization of the original peak finding algorithm suggested earlier is given. The ideology of the algorithm emerged from the well known quantum mechanical tunneling property which enables small bodies to penetrate through narrow potential barriers. We further merge this ``quantum'' ideology with the philosophy of Particle Swarm Optimization to get the global optimization algorithm which can be called Quantum Swarm Optimization. The functionality of the newborn algorithm is tested on some benchmark optimization problems.
2004-01-01
Bounding ingestion stream-tube determination via a CO tracer
Energy Technology Data Exchange (ETDEWEB)
A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.
1998-05-01
Air pollution exposure monitoring and estimation. Part 5: Traffic exposure in adults
Energy Technology Data Exchange (ETDEWEB)
In Oslo, traffic has been one of the dominating sources of air pollution in the last decade. In one part of the city where most traffic collects, two tunnels were built. A series of before and after studies was carried out in connection with the tunnels in use. Dispersion models were used as a basis for estimating exposure to nitrogen dioxide and particulate matter in two fractions. Exposure estimates were based on the results of the dispersion model providing estimates of outdoor pollutant concentrations on an hourly basis. The estimates represent concentrations in receptor points and in a square kilometre grid. The estimates were used to assess development of air pollution load in the areas, compliance with air quality guidelines, and to provide a basis for quantifying exposure-effect relationships in epidemiological studies. After both tunnels were taken in use, the pollution levels in the study areas were lower than ...
1999-08-01
Inguino-scrotal hernia detection in the early phase of a bone scan
International Nuclear Information System (INIS)
A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd
1999-11-01
Gamma scanning of FBTR fuel pins
International Nuclear Information System (INIS)
This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.
Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins
International Nuclear Information System (INIS)
A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.
Brain and bone scans in primary Ewing's sarcoma of the petrous bone: case report
International Nuclear Information System (INIS)
The authors present a case in which primary Ewing's sarcoma of the right petrous pyramid in a 9-year-old girl showed no uptake on a /sup 99m/Tc-pertechnetate nuclide angiogram. Intense uptake was present on a /sup 99m/Tc-polyphosphate bone scan, but a static brain scan was only minimally abnormal. The diagnosis and treatment of Ewing's sarcoma are reviewed.
Helical CT defecography; La defecografia con Tomografia Computerizzata spirale
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus ...
1999-11-01
International Nuclear Information System (INIS)
The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising "9"9"mTc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)
Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
2009-01-01
Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan
International Nuclear Information System (INIS)
Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal ...
2009-10-01
Wind tunnel test on a straight wing vertical-axis wind turbine with attachment on blade surface
Energy Technology Data Exchange (ETDEWEB)
There is a renewed interest in straight wing vertical axis wind turbines (SW-VAWT) which are usually installed on the roofs of high buildings in cities, urban areas and high mountain areas for independent electric power supply. SW-VAWTs have the advantages of simple design and low cost, as well as wind direction independence compared to the horizontal system. However, when SW-VAWTs are installed in cold regions, ice, snow and other attachments can affect its performance. In this study, clay was attached to the leading edge of the blade surface to determine how the performance of SW-VAWTs are affected by the mechanism of icing. Wind tunnel tests were used to study the rotational performance and power performance of the turbine blades. Icing prevention was also investigated. The attachment of clay on the leading edge of blade surface made the rotational performance of the SW-VAWT worse. The attachment of clay on the leading edge of blade surface also made the output ...
2008-07-01
The tunneling universe in scalar-tensor theory with matter
Energy Technology Data Exchange (ETDEWEB)
In this paper, the wavefunction of the universe with a tunneling boundary condition is considered in the context of the Brans-Dicke-type scalar-tensor theory with matter. The matter may be interpreted as a D-particle (or D0-brane) in string theory when the Brans-Dicke parameter {omega} is -1. We study two simple examples. The first example, the {gamma}=0 (matter) case, has a scale factor duality even if the low energy string action is coupled to matter. The universe undergoes quantum transition from super-inflationary (pre-big-bang) to deflationary (post-big-bang) phase. We calculate the transition rate by solving the Wheeler-DeWitt equation and find that it is non-vanishing. The two phases are disconnected classically. The second example is the {gamma}=1/3(radiation) case. With the help of earlier work this matter can be identified with a D0-brane in string theory. In this case, due to the absence of the scale factor duality and the complicated relations between ...
2007-10-21
Single Cooper-pair tunneling junctions using high-{Tc} superconducting materials
Energy Technology Data Exchange (ETDEWEB)
The authors introduce the single electron (Cooper-pair) tunneling junctions using c-axis Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+d} (Bi-2212) superconducting single crystal whiskers. Focused-ion-beam (FIB) etching patterned the Bi-2212 whiskers. The fabricated small stacked junctions have in-plane area S smaller than <1 {micro}m{sup 2}. The junctions showed the current-voltage (I-V) characteristics with the periodic structure of current peaks. The stacking layered structure of Bi-2212 works as multi-junctions array which decrease the effective capacitance, C{sub {Sigma}} = C{sub 0}/N, where C{sub 0} is the capacitance of junction and N is the layer number of elementary junctions. The period of current peaks of I-V curves corresponds to the charging energy of the single Cooper pair, 2Ec (=e{sup 2}/C{sub {Sigma}}).
1999-09-01
Photocurrent Noise in Quantum Dot Infrared Photodetectors
Low-frequency current noise and current-voltage (I-V) characteristics have been studied in InAs/GaAs self-assembled Quantum Dot Infrared Photodetectors in dark conditions and under illumination, at T = 77K and T = 5K. The noise behavior is consistent with a generation-recombination fluctuation process mainly related to thermally excited charge carriers at T = 77K. At T = 5K the current noise is consistent with a mechanism of fluctuations driven by the electric field, related to tunneling rather than emission-capture of charge carriers from the Quantum Dots. A very effective noise suppression mechanism, related to the tunneling regime, determines a decrease of fluctuation intensity as a function of the voltage. At T = 5K, an interesting behavior is observed in the current-voltage and noise power spectra for some of nominally identical QDIP structures in the presence of irradiation. Some devices indeed exhibit (i) a very high photoresponse and ...
2005-08-01
Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions
Energy Technology Data Exchange (ETDEWEB)
Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.
2009-05-15
InP-quantum dots in Al_0_._2_0Ga_0_._8_0InP with different barrier configurations
International Nuclear Information System (INIS)
Systematic ensemble photoluminescence studies have been performed on type-I InP-quantum dots in Al_0_._2_0Ga_0_._8_0InP barriers, emitting at approximately 1.85 eV at 5 K. The influence of different barrier configurations as well as the incorporation of additional tunnel barriers on the optical properties has been investigated. The confinement energy between the dot barrier and the surrounding barrier layers, which is the sum of the band discontinuities for the valence and the conduction bands, was chosen to be approximately 190 meV by using Al_0_._5_0Ga_0_._5_0InP. In combination with 2 nm thick AlInP tunnel barriers, the internal quantum efficiency of these barrier configurations can be increased by up to a factor of 20 at elevated temperatures with respect to quantum dots without such layers. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2009-04-01
Energy Technology Data Exchange (ETDEWEB)
In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that ...
2007-06-04
International Nuclear Information System (INIS)
In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that ...
2007-06-04
Al[sub 0. 3]Ga[sub 0. 7]As/GaAs heterojunction tunnel diode for tandem solar cell applications
Energy Technology Data Exchange (ETDEWEB)
A p[sup +]-Al[sub 0.3]Ga[sub 0.7]As/n[sup +]-GaAs heterojunction tunnel diode was fabricated using Atomic Layer Epitaxy (ALE) growth technique. Background carbon doping of [similar to]10[sup 20] cm[sup [minus]3] was achieved in the p-side of the diode by optimizing growth conditions such as V/III ratio, exposure times to reactant gases, and growth temperature. In the n-side of the diode GaAs was doped with silane and doping concentrations as high as 7[times]10[sup 18] cm[sup [minus]3] were also achieved. The dopants are chosen to satisfy the high levels and low diffusion requirements. The diode can be used to interconnect the high and low band-gap cells in the AlGaAs/GaAs cascade solar cell structure. The reactor used in this investigation is a commercial MOCVD system which has been specially modified for dual operation of ALE and MOCVD growth modes.
1994-06-30
A reactor-neutrino experiment, Daya Bay, has been proposed to determine the least-known neutrino mixing angle theta_13 using electron antineutrinos produced at the Daya Bay nuclear power complex in China. Daya Bay is an international collaboration with institutions from China, the United States, the Czech Republic, Hong Kong, Russia, and Taiwan. The experiment will use eight identical detectors deployed at three different locations optimized for monitoring the antineutrino rates from the six reactors and for detecting any rate deficit and spectral distortion near the first oscillation maximum. The overburden of the under ground experimental halls, connected with tunnels, ranges from about 250 to 900 meters-water-equivalent so that the cosmogenic background is small compared to the number of observed antineutrino events. Civil construction of tunnels and experimental facilities is planned to start in 2007, with detector construction beginning in ...
2007-01-01
Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma
International Nuclear Information System (INIS)
Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening ...
International Nuclear Information System (INIS)
Thirty-six patients with acquired immunodeficiency syndrome (AIDS), who were febrile but without localizing signs, underwent indium-111 leukocyte scintigraphy 24 hours after injection of labeled white blood cells (WBCs) and were restudied 48 hours after injection of gallium-67 citrate. Fifty-six abnormalities were identified as possible sources of the fever; 27 were confirmed with biopsy. Of these 27, 15 were identified only on In-111 WBC scans (including colitis, sinusitis, and focal bacterial pneumonia); six, only on Ga-67 scans (predominantly Pneumocystis carinii pneumonia and lymphadenopathy); and six, on both studies (predominantly pulmonary lesions). In-111 WBC scanning revealed 21 of 27 abnormalities (78%) and gallium scanning, 12 of 27 (44%). If only one scintigraphic study has been performed, particularly with Ga-67, a significant number of lesions would not have been detected. The authors ...
CT diagnosis of intrahepatic cholangiocarcinoma
International Nuclear Information System (INIS)
Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast ...
Voltage-current characteristics of point systems of metal-oxide-metal
A detection theory is developed for point-contact metal-oxide-metal (MOM) systems. A system with heterogeneous oxide strongly bonded to the substrate is considered. It is shown that the form of the functional connection between the barrier heights and the ultimate compressive strength of the oxide has no substantial influence on the voltage-current characteristics of the system. Quantitative analysis indicates that a MOM system can behave as a tunnel diode and as a diode with a Schottky barrier. The model permits the determination of the optimum construction of long-life detectors based on MOM point-contacts.-
1975-10-01
Study of radiation chemistry in solids using solid hydrogen
Energy Technology Data Exchange (ETDEWEB)
Having simple and highly symmetric structure, solid hydrogen is a useful matrix on the study of radiation-chemical processes in solid phase which have been less understood in previous studies. We have found three outstanding findings: resonance effects on the tunneling reaction H+H{sub 2} {yields} H{sub 2} + H, effects of pressure on the dissociation and recombination of H{sub 2} molecules in solid hydrogen, and high-resolution ESR spectroscopy using a solid parahydrogen matrix. (author)
2002-03-01
International Nuclear Information System (INIS)
The deferred luminescence (isothermal luminescence -ITL- and thermoluminescence - RTL) emitted by Chlorella cells after #gamma# irradiation at 77 K has been investigated. The decay kinetics of ITL as well as the effect of illumination of both ITL and RTL show that trapped electrons take part in the recombination reactions which give rise to both emissions, and that ITL can be attributed to electron tunnelling. Most strains of Chlorella studied present similar RTL glow curves, the only exceptions found being Chlorella vulgaris (green and bleached strains).
Stability against temperature variations at the ALS
Energy Technology Data Exchange (ETDEWEB)
We have studied the effects of temperature fluctuations on the Advanced Light Source (ALS). By modeling the storage ring support structure, we find that fluctuations of {plus minus}2 to 3deg C in the tunnel will cause photon beam motion of the order of the beam size. Temperature stabilization at this level will allow the residual motion of the photon beams to be reduced by a second level of active feedback, operating on signals from photon beam position monitors. Air temperature in the experimental area and the temperature of cooling water serving the beamlines should be constant to {plus minus}1deg C. This will provide a suitable environment for experiments. (orig.).
1990-05-20
Safe hole trapping, light soaking and secondary photocurrent transients in amorphous silicon
International Nuclear Information System (INIS)
A new analysis is developed for long secondary photocurrent transients which gives the distribution of trapped holes in valence band tail states. Thermally assisted tunneling to dangling bonds is implicated as the rate limiting step in hole-recombination. Light-soaking causes the energetically deeper hole traps with the longer residence times to be lost first and in the same number as would be expected for the increase in dangling bonds; This result supports a model which has hole trapping in valence tail states as a precursor to light induced dangling bonds.
1988-09-26
Rotational modes of motion for an aerodynamic pendulum with a vertical rotation axis
British Library Electronic Table of Contents (United Kingdom)
An aerodynamic pendulum placed in a steady horizontal air flow is studied in connection with modeling a wind-receiving element of a vertical-axis wind turbine (VAWT). When modeling the medium effects on the pendulum, the following two approaches are combined: the quasi-static one based on stationary wind tunnel experiments and the unsteady one based on the added mass effects. The existence of stable and unstable rotational modes is analyzed analytically (via the Poincar?-Pontryagin method) and numerically. The dependence on the parameters responsible for the viscous friction at the rotation axis and for the added mass effects is taken into account.
2009-01-01
Quantum tunnelling for Hawking radiation from a dynamical Black Hole
The paper deals with Hawking radiation related to non-static spherically symmetric black hole. Quantum corrections are incorporated using Hamilton-Jacobi method beyond semi-classical approximation. It is found that different order correction terms satisfy identical differential equation as the semiclassical action and are solved by a typical technique. It has been shown that with proper choice of the proportionality factors, one loop back reaction effect in the space time can be obtained. Finally, using the law of black hole mechanics, a general modified form of the black hole entropy is obtained considering modified Hawking temperature.
2011-01-01
Photon-assisted spin-polarized transport in carbon nanotubes with impurities
International Nuclear Information System (INIS)
Impurity effects on the photon-assisted spin-polarized transport through armchair carbon nanotubes connected with ferromagnetic leads are investigated theoretically. The impurity induces one resonant state whose position depends on the impurity strength, which can break the electron-hole symmetry. Whether the impurity suppresses or enhances the spin-coherent current depends on the nanotube length. When the microwave fields are applied on the nanotube, additional small side peaks caused by the photon-assisted tunneling are found. With increasing the impurity strength, one new current peak appears under the influence of both the microwave fields and the impurity.
2006-12-25
On Witten's instability and winding tachyons
Energy Technology Data Exchange (ETDEWEB)
We investigate, from a spacetime perspective, some aspects of Horowitz's recent conjecture that black strings may catalyze the decay of Kaluza-Klein spacetimes into a bubble of nothing. We identify classical configurations that interpolate between flat space and the bubble, and discuss the energetics of the transition. We investigate the effects of winding tachyons on the size and shape of the barrier and find no evidence at large compactification radius that tachyons enhance the tunneling rate. For the interesting radii, of order the string scale, the question is difficult to answer due to the failure of the {alpha}' expansion.
2006-12-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary ...
2002-12-01
British Library Electronic Table of Contents (United Kingdom)
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
2007-01-01
Entangled quantum currents in distant mesoscopic Josephson junctions
Energy Technology Data Exchange (ETDEWEB)
Two mesoscopic SQUID rings which are far from each other are considered. A source of two-mode nonclassical microwaves irradiates the two rings with correlated photons. The Josephson currents are in this case quantum mechanical operators, and their expectation values with respect to the density matrix of the microwaves yield the experimentally observed currents. Classically correlated (separable) and quantum mechanically correlated (entangled) microwaves are considered, and their effect on the Josephson currents is quantified. Results for two different examples that involve microwaves in number states and coherent states are derived. It is shown that the quantum statistics of the tunnelling electron pairs through the Josephson junctions in the two rings are correlated.
2004-12-22
Energy Technology Data Exchange (ETDEWEB)
The effect of the electric field on an exciton confined in a pair of vertically coupled quantum dots is studied. We use a single-band approximation and a parabolic model potential. As a result of these idealizations, we obtain a numerically solvable model, which is used to describe the influence of the electron-hole interaction on the Stark effect for the lowest-energy photoluminescence lines. We show that for intermediate tunnel coupling between the dots this interaction leads to an anomalous Stark effect with an essential deviation of the recombination energy from the usual quadratic dependence on the electric field.
2005-04-15
Boring of full scale deposition holes using a novel dry blind boring method
Energy Technology Data Exchange (ETDEWEB)
As a part of the Finnish radioactive waste disposal research three holes (the size of deposition holes) were bored in the research tunnel at Olkiluoto in Finland. A novel full-face boring technique was used based on rotary crushing of rock and removal of crushed rock by vacuum flushing through the drill string an the purpose of the work was to demonstrate the feasibility of the technique. During the boring test procedures were carried out in order to determine the effect of charges in operating parameters on the performance of the boring machine and the quality of the hole. (refs.).
1996-11-01
A twin unidirectional impulse turbine for wave energy conversion
British Library Electronic Table of Contents (United Kingdom)
A twin unidirectional impulse turbine has been proposed in order to enhance the performance of wave energy plant. This turbine system uses two unidirectional impulse turbines and their flow direction is different from each other. However, the turbine characteristics have not been clarified to date. The performances of a unidirectional impulse turbine under steady flow conditions were investigated experimentally by using a wind tunnel with large piston/cylinder in this study. Then, efficiency of the twin impulse turbine have been estimated by a quasi-steady analysis using experimental results.
2011-01-01
The value of computed tomography in the diagnosis of grating scapula
Energy Technology Data Exchange (ETDEWEB)
Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)
1994-07-01
Role of nuclear medicine bone scans in evaluating pain in athletic injuries
Energy Technology Data Exchange (ETDEWEB)
The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.
1987-10-01
Bone scanning in Ewing's sarcoma
International Nuclear Information System (INIS)
This is a retrospective analysis of bone scans in 72 patients with Ewing's sarcoma. Sites of primary disease were found to be evenly distributed among the axial skeleton and the proximal and distal extremities. Primary disease sites in the axial skeleton were more frequently associated with metastases. Fifty-three of these patients had their first scans done at presentation; among them, 25 were found to have metastases. Unsuspected metastases were picked up in 28 of all the patients. Metastases at presentation were seen to be associated with a poorer prognosis.
Energy Technology Data Exchange (ETDEWEB)
To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105/sup 0/C. The samples were then heated for 45 min in a split tube furnace at 700/sup 0/C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives values of Rainier Mesa 0.15 +- .01, Paintbrush 0.18 +- .03, Tunnel Beds 0.20 +- .04, and Grouse Canyon 0.29 +- .02. Statistically significant ...
1981-05-01
Ventilation of Ukrainian mines and its improvement
Energy Technology Data Exchange (ETDEWEB)
Mining depth in coal basins of the Ukrainian SSR increases by 12 to 18 m/year and ventilation conditions become more complicated due to increasing methane content in coal seams and hazards of coal spontaneous combustion. Over 87% of Ukrainian coal mines is characterized by methane or carbon dioxide content. In some gassy mines gas emission is as high as 173 m/SUP/3/min. Length of ventilation tunnels in Ukrainian coal mines ranges from 2.1 to 15 km and the average length amounts to 7.3 km. In underground mines of the Ukrainian SSR 730 blowers are used: 61% axial flow blowers and 39% centrifugal blowers. The following blower types are most popular: the VOKD-1.5, VOKD-1.8, VODK-2.4, VTs-25, VTs-32 and VTsD-2.2. Ventilation network of Ukrainian mines consists of 1904 coal faces and 3125 development workings. Ventilation systems used in mines are shown in 2 schemes. Trends in ventilation improvement are discussed: increase of air output by sinking new ventilation ...
1982-04-01
Scour and accretion in sub-sea structures
Energy Technology Data Exchange (ETDEWEB)
Analytical means have been developed to predict scour and accretion in sub-sea structures. Such structures can be very large and can have a large density of piping and structural members. They introduce a blocking and a shielding in the flow at the sea bottom leading to variable velocities and turbulence in the interior of the structure. This changes the transport capacity of the flow and result in general erosion where the transport capacity is increased and in accretion where the transport capacity is decreased. In addition there may occur the so-called tunnel erosion for structures built on concrete mats or similar. This type of erosion undermines the foundation of the sub-sea structure. Analytical models are developed and programmed to analyse the above phenomena. The internal flow variations are found by means of the LICengineering shielding programme and these are coupled to the transport formulae. The methodology is unstable if the starting conditions are ...
1997-09-01
Size determination of Acipenser ruthenus spermatozoa in different types of electron microscopy
British Library Electronic Table of Contents (United Kingdom)
In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde...
2010-01-01
... point dried and mounted on aluminum stubs using colloidal silver paste. Mounted specimens were observed and photographed using ... ...
New Image - ONLY - Scan to PDF - NASA Technical Reports Server
Aluminum electrolytic capacitors are presently not allowed ..... specified for commercial aluminum electrolytic capacitors of similar rating. ...
New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)
Variations,of-the ,rudder pedel force with.indicated airspeed are shown in figure 16 for the six vertical-tail configurations. -tested. ...
New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)
ratio 2 with NACA 0005-63 thickness distribution in streamwise planes, and twisted and cambered for a trapezoidal span load distribution has ...
High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry
In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.
2004-01-01
Habitat Selection by Mountain Plovers in Shortgrass Steppe
... the area covered by the point-count grid, stopping approximately every 100 m, stepping away from the vehicle, and scanning with binoculars for mountain plovers. Once ... ...
FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
International Nuclear Information System (INIS)
English 1993 p. 161-163 China Zhu Rongbao Yang Liucheng Zhang
Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning
International Nuclear Information System (INIS)
The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).
Advances in Modeling of Scanning Charged-Particle-Microscopy Images
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This work describes scanning in charged-particle microscopes, which is applied both in the artificial image generator and the DCIC ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an ...
1996-03-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the methodology and the results from the modelling of an open repository for spent nuclear fuel in Laxemar. Specifically, the present work analyses the hydrological effects of the planned repository during the construction and operational phases when it is open, i.e. air-filled, and hence may cause a disturbance of the hydrological conditions in the surroundings. The numerical modelling is based on the SDM-Site Laxemar MIKE SHE model. The modelling was divided into three steps. The first step was to update the SDM-Site Laxemar model with a new hydrogeological bedrock model. The other main updates were an increase of the depth of the MIKE SHE model domain, enhanced vertical computational resolution and that the drainage of the Aespoe Hard Rock Laboratory was included in the model. The resulting model was used to simulate undisturbed natural conditions. The next step was to describe the open repository conditions, using Laxemar layout D2, by implementing the access ...
2009-10-15
UK PubMed Central (United Kingdom)
BackgroundThe Prospective Space-Time scan statistic (PST) is widely used for the evaluation of space-time clusters of point event data. Usually a window of cylindrical shape is employed,...Full Text Available
Practical MRI atlas of neonatal brain development
International Nuclear Information System (INIS)
This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.
Paraquat-induced pulmonary lesions : HRCT findings in long-term follow-up : a case report
International Nuclear Information System (INIS)
We illustrate serial HRCT findings over a 16-month period in a 35-year-old woman who had ingested paraquat. Initial areas of ground-glass opacity changed into areas of multiple air cysts on follow up scan obtained five months after ingestion. A further follow-up scan obtained 16 months after ingestion showed improvement, with increased lung volume and normalized lung architecture.
1997-03-01
Magnetic resonance imaging in acute intractional tuberculosis
International Nuclear Information System (INIS)
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
Isolated dextrogastria: report of two cases
International Nuclear Information System (INIS)
Isolated situs inversus of the stomach with otherwise normal position of the thoracic and abdominal viscera is an extremely rare anomaly occurring in two distinct forms. Because of its close relationship to the liver, the right-sided stomach may produce interesting and confusing changes in the liver scan. Two cases illustrate the radiologic features of the two principal types of isolated congenital dextrogastria and the effect of one type on the liver scan.
Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system
International Nuclear Information System (INIS)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
Energy Technology Data Exchange (ETDEWEB)
We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)
2001-02-01
International Nuclear Information System (INIS)
The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.
1989-09-10
Development of heavy-ion irradiation technique for single-event in semiconductor devices
Energy Technology Data Exchange (ETDEWEB)
Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)
1997-03-01
Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle
Energy Technology Data Exchange (ETDEWEB)
The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.
1988-10-13
International Nuclear Information System (INIS)
A bone scan can be negative in Ewing's sarcoma. The bone scan during and after treatment can give prognostic information on the primary tumor site: A persisting hot spot strongly suggests the presence of local malignancy, while a hot spot becomming negative points to local cure of Ewing's sarcoma. (orig.).
Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues
Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a function of depth in tissue phantoms with a range of relevant optical properties. The phantom data agree ...
2011-02-01
Diagnosis of plasmocytomas using magnetic resonance imaging
International Nuclear Information System (INIS)
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...
2000-08-01
Development of a HVDC prototype breaker. Final report
Energy Technology Data Exchange (ETDEWEB)
The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. ...
1980-06-01
Energy Technology Data Exchange (ETDEWEB)
Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level ...
1984-09-01
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
International Nuclear Information System (INIS)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...
2007-03-15
Transition-metal dimers and physical limits on magnetic anisotropy
British Library Electronic Table of Contents (United Kingdom)
Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...
2007-01-01
Three dimensional shock wave/boundary layer interactions
British Library Electronic Table of Contents (United Kingdom)
An investigation into a three-dimensional, curved shock wave interacting with a three-dimensional, curved boundary layer on a slender body is presented. Three different nose profiles mounted on a cylindrical body were tested in a supersonic wind tunnel and numerically simulated by solving the Navier?Stokes equations. The conical and hemispherical nose profiles tested were found to generate shock waves of sufficient strength to separate the boundary layer on the cylinder, while the shock wave generated by the ogival profile did not separate the boundary layer. For the separated flow, separation was found to occur predominantly on the windward side of the cylinder with the lee-side remaining shielded from the direct impact of the incident shock wave. A thickening of the boundary layer on the...
2011-01-01
International Nuclear Information System (INIS)
We consider a SQUID ring inductively coupled to an electromagnetic field mode, both treated quantum mechanically. We demonstrate a method for creating a maximally entangled state between the ring and the field mode. Our method utilises a non-adiabatic external magnetic flux pulse to move into and out of a transition region. Hence, our approach is fundamentally different to techniques based on Landau-Zener tunnelling that can also be used to achieve similar results. Our analysis is extended to include the effects of coupling the system to a dissipative environment. With this model we show that although such an environment makes a noticeable difference to the time evolution of the system, it need not destroy the entanglement of this coupled system over time scales required for quantum technologies.
2010-07-01
Tachyons in gravitational field
International Nuclear Information System (INIS)
Behaviour of tachyons in gravitational field has been investigated by using imaginary as well as real superluminal Lorentz transformations. Using real superluminal transformations in four- and six-dimensional space-time, an expression for the gravitational force acting on a tachyon, moving along the tachyon corridor constructed to follow the tachyon geodesic, has been derived. The motion of a tachyon through a black hole has also been discussed and it is shown that the black hole acts like a gravitational tunnel for tachyons and the transition between the regions inside and outside the horizon can be understood as real superluminal transformations transforming a R"4=(r,t) world into a T"4=(t,r) world. 36 refs.. (author).
International Nuclear Information System (INIS)
Electron-beam codeposition of the elements to form certain high critical temperature superconducting materials, in particular A-15 compounds, has proven to be very useful in research directed at understanding and improving their superconducting properties. This work has used the close control of three or more evaporant sources to reproducibly make specimens that permit studies across selected regions of composition and phase space. The effect of composition and phase, together with the temperature and rate of deposition, on the growth morphology and superconducting properties has been studied. The superconducting properties measured include the critical temperature, ac loss, critical current density, and tunnel junction characteristics. The particular compounds studied include Nb_3Sn, Nb_3Ge, and V_3Si.
International Nuclear Information System (INIS)
HLW disposal is one of the largest issue to utilize Nuclear power safely. In the past study, the concept, which buffer materials and Overpacked waste were transported into underground respectively, have shown. The concept of pre-assembled engineered barrier has advantage to simplify the logistics and emplacement procedure, however there are difficulties to support heavy weight of pre-assembled package by equipment under the condition of little clearance between tunnel and package. In this study, Combination of air bearing and two degree-of-freedom wheels were suggested for transportation, and air jack was suggested for unloading and emplacement system. Also, whole system for transportation and emplacement procedure was designed, and Scale model test was examined to evaluate the feasibility of these concept and functions. (author)
2009-11-01
Spin qubits in antidot lattices
DEFF Research Database (Denmark)
We suggest and study designed defects in an otherwise periodic potential modulation of a two-dimensional electron gas as an alternative approach to electron spin based quantum information processing in the solid-state using conventional gate-defined quantum dots. We calculate the band structure and density of states for a periodic potential modulation, referred to as an antidot lattice, and find that localized states appear, when designed defects are introduced in the lattice. Such defect states may form the building blocks for quantum computing in a large antidot lattice, allowing for coherent electron transport between distant defect states in the lattice, and for a tunnel coupling of neighboring defect states with corresponding electrostatically controllable exchange coupling between different electron spins.
2008-01-01
Quasienergy description of the driven Jaynes-Cummings model
We analyze the driven resonantly coupled Jaynes-Cummings model in terms of a quasienergy approach by switching to a frame rotating with the external modulation frequency and by using the dressed atom picture. A quasienergy surface in phase space emerges whose level spacing is governed by a rescaled effective Planck constant. Moreover, the well-known multiphoton transitions can be reinterpreted as resonant tunneling transitions from the local maximum of the quasienergy surface. Most importantly, the driving defines a quasienergy well which is nonperturbative in nature. The quantum mechanical quasienergy state localized at its bottom is squeezed. In the Purcell limited regime, the potential well is metastable and the effective local temperature close to its minimum is uniquely determined by the squeezing factor. The activation occurs in this case via dressed spin flip transitions rather than via quantum activation as in other driven nonlinear quantum systems such as ...
2010-01-01
On the curvature in logarithmic plots of rate coefficients for chemical reactions
In terms of the reduced potential energy barrier ? = ?uTS/kT, the rate coefficients for chemical reactions are usually expressed as proportional to e-?. The coupling between vibrational modes of the medium to the reaction coordinate leads to a proportionality of the regularized gamma function of Euler Q(a,?) = ?(a,?)/?(a), with a being the number of modes coupled to the reaction coordinate. In this work, the experimental rate coefficients at various temperatures for several chemical reactions were fitted to the theoretical expression in terms of Q(a,?) to determine the extent of its validity and generality. The new expression affords lower deviations from the experimental points in 29 cases out of 38 and it accounts for the curvature in the logarithmic plots of rate coefficients versus inverse temperature. In the absence of tunneling, conventional theories predict the curvature of these plots to be identically zero.
2011-05-06
Numerical analysis of design parameters for a generic fan-in-wing configuration
British Library Electronic Table of Contents (United Kingdom)
The present investigation focuses on the study of design parameters for a generic fan-in-wing configuration. The objective is to evaluate the performance of a fan-in-wing concept in a Short-Take-Off and Landing situation. The results presented are also of interest for transition between hover and a wing-sustained flight for a Vertical Take Off and Landing concept. Steady Reynolds Averaged Navier-Stokes computations using an actuator disk technique are performed. The results show a good agreement with experimental data and simulation results obtained in previous investigations for a generic wind tunnel model. A parametric study is conducted for a more realistic wing planform. For a single fan installed in the wing, the streamwise and spanwise influence on the wing aerodynamics is studied. I...
2010-01-01
Nuclear fission with mean-field instantons
We present a description of nuclear spontaneous fission, and generally of quantum tunneling, in terms of instantons - periodic imaginary-time solutions to time-dependent mean-field equations - that allows for a comparison with more familiar and used generator coordinate (GCM) and adiabatic time-dependent Hartree-Fock (ATDHF) methods. It is shown that the action functional whose value for the instanton is the quasiclassical estimate of the decay exponent fulfils the minimum principle when additional constraints are imposed on trial fission paths. In analogy with mechanics, these are conditions of energy conservation and the velocity-momentum relations. In the adiabatic limit the instanton method reduces to the time-odd ATDHF equation, with collective mass including the time-odd Thouless-Valatin term, while the GCM mass completely ignores velocity-momentum relations. This implies that GCM inertia generally overestimates instanton-related decay rate. The very ...
2007-01-01
Neutrino tagging through secondary beam scraping
We discuss an experimental technique aimed at tagging electron neutrinos in multi-GeV artificial sources on an event-by-event basis. It exploits in a novel manner calorimetric and tracking technologies developed in the framework of the LHC experiments and of rare kaon decay searches. The setup is based on an instrumented decay tunnel equipped with tagging units that intercept secondary and tertiary leptons from the bulk of undecayed pi+ and protons. We show that the taggers are able to reduce the nue contamination originating from K_e3 decays by about one order of magnitude. Only a limited suppression (~60%) is achieved for nue produced by the decay-in-flight of muons; for moderate beam powers, similar performance as for K_e3 can be reached supplementing the tagging system with an instrumented beam dump.
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Microcrystalline-Si thin-film transistors (?C-Si TFTs) formed by using the source/drain contact electrode of self-aligned palladium silicide have been investigated. Both the self-aligned palladium silicided scheme and the previous top-gate staggered structure employ two-mask process steps for fabricating ?C-Si TFTs. However, the self-aligned palladium silicided scheme would cause better device characteristics than the top-gate staggered structure, primarily due to more carrier tunneling. For a gate length of 2 ?m, as compared to the top-gate staggered scheme, this silicided scheme can result in a 40% improvement of on-state current. In addition, as the gate length is reduced to 1 ?m, considerable short-channel effect is caused for both the device schemes.
2010-01-01
J/Psi dissociation in parity-odd bubbles
We calculate the quarkonium dissociation rate in the P and CP-odd domains (bubbles) that were possibly created in heavy-ion collisions. In the presence of the magnetic field produced by the valence quarks of colliding ions, parity-odd domains generate electric field. Quarkonium dissociation is the result of quantum tunneling of quark or antiquark through the potential barrier in this electric field. The strength of the electric field in the quarkonium comoving frame depends on the quarkonium velocity with respect to the background magnetic field. We investigate momentum, electric field strength and azimuthal dependence of the dissociation rate. Azimuthal distribution of quarkonia surviving in the electromagnetic field is strongly anisotropic; the form of anisotropy depends on the relation between the electric and magnetic fields and quarkonium momentum. These features can be used to explore the properties of the electromagnetic field created in heavy ion ...
2011-01-01
Generation of the scalar field and anisotropy at quantum creation of the closed universe
Energy Technology Data Exchange (ETDEWEB)
The behaviour of the wave function of the universe under the barrier for the anisotropic cosmological Bianchi type-IX model taking account of the scalar field is explored. In view of the known difficulties with the interpretation of multidimensional ones is offered. For this purpose in the frameworks of the semiclassical approach the system of characteristics equations relative to one variable is written out. This system describes a bundle of the characteristics along which the multidimensional problem is reduced to a one-dimensional one that allows to utilize the standard interpretation of the wave function as well as the usual Schroedinger equation. The obtained results for the Bianchi type-IX model are reduced to the following statement: the universe tunnels through the barrier from an isotropic state with small anisotropy that is necessary for providing a ling-lived inflation to derive the universe.
2000-09-01
Flutter control effect and mechanism of central-slotting for long-span bridges
British Library Electronic Table of Contents (United Kingdom)
The flutter control effect and mechanism of central-slotting, which have gradually been adopted in the design and construction of long-span bridges as an effective flutter controlling measure, were investigated with theoretical analysis and wind tunnel test. Five basic girder cross-sections representing five typical aerodynamic configurations were selected and central-slotted with two different slot widths. Then, a series of sectional model tests and theoretical analyses based on the two-dimensional three-degrees-of-freedom coupling flutter analysis method (2 dimension-3 degrees of freedom method, 2d-3DOF method) were carried out to investigate the aerody namic performance, flutter mechanism and flutter modality of the five basic sections and their corresponding central-slotted sections. T...
2007-01-01
Energy saver A-sector power test results
Energy Technology Data Exchange (ETDEWEB)
The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.
1982-09-15
Effect of wing planform on leading-edge vortex structures
British Library Electronic Table of Contents (United Kingdom)
Flow visualization experiments are conducted in water tunnel for low aspect ratio cropped wings at low Reynolds number. The experimental results show that the model sweep angle ? influences the formation and development of the leading-edge vortex. For wings with ? =0?, the dominant flow structure is transverse vortex. When ??26?, the dual vortex structure can be observed at some angles of attack, and it is confirmed that the dual vortex is a special structure for flow over low aspect ratio wing at low Reynolds number. For ??56? wings, the dual vortex structure can be observed in a large range of attack angles. Moreover, in comparison with the outer vortex, the breakdown position of the primary vortex is delayed, and the larger the ?, the later the breakdown location at the same angle of at...
2010-01-01
Development of flexible joint for 500kV Al-sheathed O. F. cable
Energy Technology Data Exchange (ETDEWEB)
This paper reports on a flexible dimensionaly flush joint for 500kV aluminum-sheathed oil-filled cables capable of being assembled, pulled an installed in a similar manner to cables at site which has been developed. This joint is intended for use at intermediate points on long bridges or tunnels where local assembly and installation of conventional joints would be difficult. In developing the joint various novel and original techniques have been employed, including the flexible flush jointing of segmental conductors, the flexible jointing of paper insulation by a combination of wrapping-back and stepping methods, plus on-site aluminum sheath corrugating and sealing methods.
1992-10-01
British Library Electronic Table of Contents (United Kingdom)
The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...
2010-01-01
Designed defects in 2D antidot lattices for quantum information processing
DEFF Research Database (Denmark)
We propose a new physical implementation of spin qubits for quantum information processing, namely defect states in antidot lattices defined in the two-dimensional electron gas (2DEG) at a semiconductor heterostructure. Calculations of the band structure of a periodic antidot lattice are presented. A point defect is created by removing a single antidot, and calculations show that localized states form within the defect, with an energy structure which is robust against thermal dephasing. The exchange coupling between two electrons residing in two tunnel-coupled defect states is calculated numerically. We find results reminiscent of double quantum dot structures, indicating that the suggested structure is a feasible physical implementation of spin qubits.
2008-01-01
Dependence of nitriding degree of Ti surface by non-LTE nitrogen plasma on various plasma parameters
International Nuclear Information System (INIS)
Experiments of plasma nitriding of titanium are carried out by two plasma sources. One is a microwave discharge plasma source under several Torr, and the other is a nitrogen arc jet generated under atmospheric pressure followed by rapid expansion into a gas wind tunnel. The relationship between the surface density of nitrogen atoms in the #alpha#-Ti and various plasma parameters is systematically studied. For the microwave nitrogen plasma, it is found that the effect of the vibration temperature is the most essential for the surface nitriding, whereas the effect of electron temperature, density and rotation temperature is less remarkable. It is also found that the higher vibration temperature of the microwave discharge nitrogen plasma makes the target temperature higher, and consequently, the surface density of atomic nitrogen remarkably increased. However, the effect of target temperature is less remarkable for the arc jet nitrogen plasma.
2004-06-01
International Nuclear Information System (INIS)
Two different techniques were used for measuring Rn-gas concentrations and Working Level (WL) in U-exploration galleries at El-Allouga Mine, Sinai, Egypt. The active techniques used EDA(RDA-200) with calibrated Lucas cell and Tri-Met-372 instruments and passive techniques used four different types of SSNTD. Twenty eight (28) stations inside the studied tunnels were located covering the different environmental conditions. The measurements were carried out during summer time, in the ventilated sector (16 stations), the average tunnel air temperature was 24.4 #+-# 2.2 degree C and relative humidity 38%. In the non-ventilated sector (12 stations), the average tunnel air temperature was 22.2#+-#0.4 degree C and relative humidity 70%. The Rn-gas concentrations using EDA(RDA-200) and calibrated Lucas cell, in the ventilated sector averaged 11.966 p Ci/l, while in the non-ventilated stations averaged 786.21 p Ci/l. Also for the ...
2007-04-22
Boring of full scale deposition holes using a novel dry blind boring method
Energy Technology Data Exchange (ETDEWEB)
Three holes the size of deposition holes (depth 7.5 m and diameter 1.5 m) were bored in the Research Tunnel at Olkiluoto, Finland. A novel full-face boring technique was used based on rotary crushing of rock and removal of crushed rock by vacuum flushing through the drill string. The purpose of the work was to demonstrate the feasibility of the technique. During the boring test procedures were carried out in order to determine the effect of changes in operating parameters on the performance of the boring machine and the quality of the hole. The boring method was found to be technically feasible and efficient. Evaluation of the quality of the hole included studies of the geometry of the hole, measurements of the surface roughness using a laser profilometer and study of excavation disturbances in the zone adjacent to the surface of the holes using two novel methods, He-gas diffusion and the {sup 14}C-polymethylmethacrylate methods. 43 refs.
1996-10-01
Bladder Injuries During Laparoscopic Orchiopexy: Incidence and Lessons Learned
British Library Electronic Table of Contents (United Kingdom)
Purpose Laparoscopic orchiopexy is a safe operation. However, the bladder can be injured during creation of the transperitoneal tunnel for the cryptorchid testis. We reviewed our experience with this complication. Materials and Methods We searched the operative notes of patients who had undergone laparoscopic orchiopexy between August 15, 2002 and October 1, 2008, and identified bladder injuries and their treatment. Results A total of 93 patients underwent laparoscopic orchiopexies for 101 undescended testes during the study interval, with 3 procedures resulting in bladder injuries. The 3 operations varied with regard to whether the injury was recognized intraoperatively or postoperatively, and repaired in an open or laparoscopic fashion. Conclusions Bladder injury during laparoscopic orch...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Papers are presented on the modeling, dispersion, formation, transformation, monitoring and biological effects of atmospheric pollution. Specific topics include a prognostic mesoscale model for pollutant transport and diffusion, commuter exposure modeling, a Gaussian plume model for an urban area, carbon monoxide dispersion in an urbanized area, wind-tunnel modeling of flue gas dispersion, the regional-scale transport of fine aerosol components in eastern North America, and a Markov process for the generation of hourly average wind vectors. Attention is also given to photochemical aerosol formation in multicomponent systems, heterogeneous nitrogen oxide-particulate reactions, the generation and measurement of primary soot aerosols of size between 50 and 400 A, inertial particle size classification techniques, the design of air quality monitoring networks, visibilities in polluted and unpolluted areas, and monitoring air quality according to an analysis of ...
1980-01-01
Assessing soil quality under intensive cultivation and tree orchards in Southern Italy
British Library Electronic Table of Contents (United Kingdom)
Concerns about groundwater contamination as well as pesticide residues in food and soil have fuelled vigorous debates about the sustainability of chemical-intensive agriculture. Search has been prompted for agronomic strategies with lower environmental hazards. In this multidisciplinary study we compared the characteristics of soils from 20 agricultural farms selected in five geographical areas of Southern Italy with different soil types. In each farm, fields with management regime classified as high-input (HIMR, intensive cultivation under plastic tunnels) or low-input (LIMR, tree orchards) were selected. Soil samples were analyzed for 31 parameters including physical and chemical properties (bulk density, water holding capacity, texture, pH, limestone, electrical conductivity, organic C ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This volume is based on the proceedings of the CERN Accelerator School's course on Applied Geodesy for Particle Accelerators held in April 1986. The purpose was to record and disseminate the knowledge gained in recent years on the geodesy of accelerators and other large systems. The latest methods for positioning equipment to sub-millimetric accuracy in deep underground tunnels several tens of kilometers long are described, as well as such sophisticated techniques as the Navstar Global Positioning System and the Terrameter. Automation of better known instruments such as the gyroscope and Distinvar is also treated along with the highly evolved treatment of components in a modern accelerator. Use of the methods described can be of great benefit in many areas of research and industrial geodesy such as surveying, nautical and aeronautical engineering, astronomical radio-interferometry, metrology of large components, deformation studies, etc.
1987-01-01
Application of activated charcoal radon collectors in high humidity environments
Energy Technology Data Exchange (ETDEWEB)
Most commercially based activated charcoal radon collectors were designed for use in indoor environments. However, at present, they are often used for research in radon surveys in unique environments, such as in the bathrooms, underground areas, mines, caves and tunnels. In these environments, the relative humidity would be around 100%, and a change in the sensitivity of cpm(Bq m{sup -3}){sup -1}(radon) would occur. For this study, the reduction in the sensitivity of activated charcoal radon collector due to environmental humidity was investigated, and the data correction was discussed. Here, ST-100 (Pico-Rad) was selected as an example of a familiar activated charcoal radon collector. According to our performance test, the humidity of 90% (20 deg. C) resulted in a 15% reduction of the sensitivity for 24 h collection. The ST-100 user should discuss the necessity of data correction by comparing the change of sensitivity with other levels of estimation errors.
2004-09-01
A new aspect of superconductivity in A-15 compounds
International Nuclear Information System (INIS)
We present a new aspect of superconductivity in A-15 compounds which is able to explain their exceptional role among the high Tc superconductors. The basic idea is that a strong energy dependence of the the electronic density of states near the Fermi level may greatly reduce the repulsive part of the frequency dependent electron-phonon interaction. This leads to a large enhancement of Tc which is a maximum when the Fermi energy is comparable to a typical phonon energy. Our findings are based on numerical solutions of the Eliashberg equations where both the retardation of the electron-phonon coupling and the energy dependence of the electronic density of states have been included. For the electronic density of states we use the models of Labbe and Friedel and of Cohen et al., while the shape of the Eliashberg function #alpha#"2F(#omega#) is taken from the tunneling results of Shen. We compare our theory to experimental results for ternary A-15 compounds. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
We present a 1-D heat transfer, melting, vaporization and resolidification model describing the interaction of a scanning continuous-wave laser with a metal surface wherein the beam power is constant. A physical model based on the Stefan problem is developed with appropriate boundary conditions. The effects of processing parameters on process variables are investigated numerically by varying beam diameters, scan speeds and substrate temperatures for Nickel. Relations are derived for the times to initiate melting, to initiate vaporization, to reach maximum melting depth, for melting-resolidification, and for maximum melting and vaporization depths. Surface temperatures are compared with approximate closed form solutions. (Author)
2004-09-01
International Nuclear Information System (INIS)
Scanning thermal microscopy (SThM) was used to map thermal conductivity images in an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment (SMAT). It is found that the deformed surface layer shows different thermal conductivities that strongly depend on the grain size of the microstructure: the thermal conductivity of the nanostructured surface layer decreases obviously when compared with that of the coarse-grained matrix of the sample. The role of the grain boundaries in thermal conduction is analyzed in correlation with the heat conduction mechanism in pure metal. A theoretical approach, based on this investigation, was used to calculate the heat flow from the probe tip to the sample and then estimate the thermal conductivities at different scanning positions. Experimental results and theoretical calculation demonstrate that SThM can be used as a tool for the thermal property and microstructural analysis of ...
2006-06-15
Interpretation of gamma-scanning data from the ORR demonstration elements
Energy Technology Data Exchange (ETDEWEB)
The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.
1989-01-01
High speed inverted optical-resolution photoacoustic microscopy
Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.
2011-02-01
UK PubMed Central (United Kingdom)
Extending genome wide association analysis by the inclusion of gene expression data may assist in the dissection of complex traits. We examined piebald, a pigmentation phenotype in both human and Merino...Full Text Available
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
UK PubMed Central (United Kingdom)
The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available
2010-01-01
TO: All GCN Notice recipients RE
These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...
International Nuclear Information System (INIS)
English Oct 1996 p. 352-353 Brazil Maliska, Ana Maria Kuehn, Ingeborg Klein,
1996-10-01
UK PubMed Central (United Kingdom)
Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass...Full Text Available
2009-12-01
Spacecraft and Instruments - NASA
Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...
PrognoScan: a new database for meta-analysis of the prognostic value of genes
UK PubMed Central (United Kingdom)
BackgroundIn cancer research, the association between a gene and clinical outcome suggests the underlying etiology of the disease and consequently can motivate further studies. The...Full Text Available
Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults
UK PubMed Central (United Kingdom)
Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available
2010-03-01
Performance of a modified two-dimensional gamma scan system in spent fuel pin studies
International Nuclear Information System (INIS)
This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified system. (author)
1999-11-01
Performance characterization of a volumetric breast ultrasound scanner
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good ...
2007-03-01
Optical sectioning of microbial biofilms.
UK PubMed Central (United Kingdom)
Scanning confocal laser microscopy (SCLM) was used to visualize fully hydrated microbial biofilms. The improved rejection of out-of-focus haze and the increased resolution of SCLM made it preferable...Full Text Available
1991-10-01
Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot
UK PubMed Central (United Kingdom)
There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available
UK PubMed Central (United Kingdom)
Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available
1981-05-01
Magnetic resonance imaging findings in 46 elbows with a radial head fracture
UK PubMed Central (United Kingdom)
Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available
2010-06-01
Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism
UK PubMed Central (United Kingdom)
BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available
2011-01-01
Lameness, Activity Time-Budgets, and Estrus Expression in Dairy Cattle
UK PubMed Central (United Kingdom)
The aim of the present study was to identify specific behavioral patterns that contribute to diminished estrus expression in lame cows. Behavioral scan and focal sampling were used to examine...Full Text Available
2008-12-01
Kaposi's sarcoma involving the thyroid in a patient with AIDS
International Nuclear Information System (INIS)
A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...
UK PubMed Central (United Kingdom)
The torque-velocity relationship is known to be affected by ageing, decreasing its protective role in the prevention of falls. Interindividual variability in this torque-velocity relationship is partly...Full Text Available
2008-09-01
Energy Technology Data Exchange (ETDEWEB)
This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.
1983-01-01
Field experience with eddy current X-probes in CANDU steam generators and heat exchangers
Energy Technology Data Exchange (ETDEWEB)
CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...
2006-07-01
Field experience with eddy current X-probes in CANDU steam generators and heat exchangers
International Nuclear Information System (INIS)
CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...
2005-11-20
Energy Technology Data Exchange (ETDEWEB)
In the paper six cases of facial osteomyelitis as a complication of chronic sinusitis in hemophiliac-AIDS patients are reported. Osteomyelitis was suggested by an increasing of erythrocyte sedimentation rate. The diagnosis was confirmed by a positive {sup 99m} Tc MDP scintigraphy. The patients were submitted to clinical treatment. The erythrocyte sedimentation rate and 67-gallium citrate scans were used in the follow-up of the therapy. Three patients had negative gallium after three weeks of organism-specific antibiotic therapy; in two patients the gallium scintigraphy remained positive. One patient did not undergo the radionuclide scan for this clinical conditions. These results suggest that MDP scans showed higher sensitivity and specificity in detection of bone disease in chronic sinusitis. Gallium scans appeared to be valuable tool in the follow-up of the infection. There are no reports in the ...
1997-01-01
Experimental Electron Heat Diffusion in TJ-II ECRH Plasmas
Energy Technology Data Exchange (ETDEWEB)
Interpretative transport has been used to revisit the global scalings of TJ-II ECRH plasmas from a local perspective. Density, rotational transform and ERCH power scans were analysed based upon Thomson Scattering data (electron density and temperature) in steady state discharges. A simple formula to obtain the thermal conductivity, assuming pure diffusion and negligible convective heat fluxes was used in a set of 161 discharges. All the analysis was performed with the ASTRA transport shell. The density scan indicates that inside n=0,4 there is no significant change of e with density in the range studied (0.4 <ne>(1019m-3) 1.0), while in 0,5 <0,8 approximately, e decreases with density. In the rotational transform scan it is found that the values of e when a low order rational of the rotational transform is present locally seem to be smaller for the corresponding range, although it is apparent a general ...
2006-07-01
Electronic and Interfacial Properties of Pd/6H-SiC Schottky Diode ...
and palladium silicides (Pd,Si) with a total. AES intensity ratio of Pd to Si of 35/65. Scanning Electron Microscopy. (SEM') of the Pd region shows that ...
Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging
International Nuclear Information System (INIS)
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
UK PubMed Central (United Kingdom)
Thermal behaviors of eucalyptus wood residue (EWR) filled recycled high density polyethylene (HDPE) composites have been measured applying the thermogravimetric analysis (TGA) and differential scanning...Full Text Available
UK PubMed Central (United Kingdom)
Because the results with cobalt-57-bleomycin (57Co-bleo) as a tumour-seeking agent in patients with pulmonary tumours were promising, a prospective study was carried out to test the sensitivity and...Full Text Available
1976-12-01
Catheter Ablation for Paroxysmal Atrial Fibrillation
... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...
UK PubMed Central (United Kingdom)
Differential scanning calorimetric (DSC) studies of the glassy states of as-received and hydrated lysozyme, hemoglobin, and myoglobin powders, with water contents of < or = 0.25, < or...Full Text Available
1994-01-01
UK PubMed Central (United Kingdom)
The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available
1993-04-01
UK PubMed Central (United Kingdom)
PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available
2011-02-01
Atelectasis on pediatric chest CT: comparison of sedation techniques
International Nuclear Information System (INIS)
Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). ...
1999-07-01
International Nuclear Information System (INIS)
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)
2001-09-01
An unusual presentation of metastatic adenocarcinoma of lung: a case report
UK PubMed Central (United Kingdom)
We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available
Amorphous to crystalline phase transformation in Metglas reg-sign studied by Moessbauer spectroscopy
International Nuclear Information System (INIS)
The authors present differential scanning calorimetry (DSC) and in situ Moessbauer spectroscopy results for Metglas ribbons, to which different heat treatments were made. The Curie temperature of the amorphous phase is determined and the evolution of the magnetic field of this phase is studied as a function of temperature
1997-12-01
UK PubMed Central (United Kingdom)
The lung of the lesser bushbaby (Galago senegalensis) has been investigated morphologically and morphometrically using the transmission and scanning electron microscopes. Grossly and microscopically,...Full Text Available
1990-10-01
A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT
UK PubMed Central (United Kingdom)
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
2010-01-01
Scintigraphic detection of a radiologically equivocal fracture
Energy Technology Data Exchange (ETDEWEB)
This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period.
1988-04-01
Scintigraphic detection of a radiologically equivocal fracture
International Nuclear Information System (INIS)
This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Primary B-cell lymphoma of thymus is uncommon. We describe the case of a 23-year-old woman with a history of shortness of breath and distended neck veins of 1-month duration. A chest roentgenogram and computed tomographic chest scan of the showed a large anterior mediastinal mass. Tru-cut biopsy revealed primary B-cell lymphoma of thymus. She underwent chemotherapy with no symptomatic improvement. Post-chemotherapy computed tomographic scan of the chest showed no appreciable reduction in tumor size. Surgical excision was carried out with excellent results.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
2011-01-01
International Nuclear Information System (INIS)
Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.
2009-11-25
Beam position monitor readout and control in the SLC linac
Energy Technology Data Exchange (ETDEWEB)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
1985-04-01
International Nuclear Information System (INIS)
Wind tunnel tests were performed of three fugitive dust control agents derived from potato and sugar beet products. These materials are being considered for use as dust suppressants to reduce the potential for transport of radioactive materials by wind from radioactive waste construction and remediation sites. Soil and dust control agent type, solution concentrations, application quantities, aging (or drying) conditions, surface disturbance, and wind and saltating sand eolian erosive stresses were selected and controlled to simulate application and exposure of excavated soil surfaces in the field. A description of the tests, results, conclusions, and recommendations are presented in this report. The results of this study indicate that all three dust control agents can protect exposed soil surfaces from extreme eolian stresses. It is also clear that the interaction and performance of each agent with various soil types may differ dramatically. Thus, soils similar to ...
1993-01-01
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
Energy Technology Data Exchange (ETDEWEB)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock ...
2008-04-15
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
International Nuclear Information System (INIS)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock ...
Energy Technology Data Exchange (ETDEWEB)
This paper introduces a multichannel digital data acquisition system and examples of measurements with the system in seismic exploration using the high resolution seismic refraction method. The high resolution seismic refraction system performs analyses nearly automatically by using a computer after initial travel time has been read. Therefore, the system requires high-accuracy travel time data, for which a multichannel digital measuring instrument developed recently for seismic exploration using the refraction method has been used for the measurement. The specification specifies the number of channels at 144 as a maximum, a sampling time of 62.5 {mu}sec to 4 m sec, the maximum number of sampling of 80,000 samples, and gain accuracy of {plus_minus} 1%. The system was used for surveying a tunnel having a maximum soil cover of about 800 m. The traverse line length is about 6 km, the distance between vibration receiving points is 50 m, and the number of vibration ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
We report on a new experimental approach to the size estimation of the hot spot induced by ionizing particles in a Josephson tunnel junction. Here, in contrast to the case of a superconducting strip, it is possible to investigate the hot spot dynamics in absence of effects due to the heating induced by the bias current. The reported experiment is based on the motion of Abrikosov vortices, trapped in the thin films constituting the junction electrodes, under 5.6 MeV {alpha}-particle irradiation. The fast time evolution of a hot spot, combined with the presence of Abrikosov vortices, produces a change of the static magnetic field in the junction area and thus a change of the critical current value, I{sub c}. Measurements of I{sub c} during the {alpha}-particle irradiation and in presence of trapped Abrikosov vortices allow to determine the rate of appearance of those I{sub c} changes. The behavior of the average appearance rate as function of the Abrikosov vortices ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work is to determine the extent to which drill water might be expected to be imbibed by core samples taken from densely welded tuff. In a related experimental study conducted in G-Tunnel, drill water imbibition by the core samples was observed to be minimal. Calculations were carried out with the TOUGH code with the intent of corroborating the imbibition observations. Due to the absence of hydrologic data pertaining directly to G-Tunnel welded tuff, it was necessary to apply data from a similar formation. Because the moisture retention curve was not available for imbibition conditions, the drainage curve was applied to the model. The poor agreement between the observed and calculated imbibition data is attributed primarily to the inappropriateness of the drainage curve. Also significant is the value of absolute permeability (k) assumed in the model. Provided that the semi-log plot of the drainage and imbibition moisture ...
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
Inverted growth and the development of associated cell processing, are likely to offer a significant degree of freedom for improving the performance of many III-V multijunction cascades and open new avenues for advanced multijunction concepts. This is especially true for the development of high-efficiency Al[sub 0.37]Ga[sub 0.63]As/GaAs cascades where the high growth temperatures required for the AlGaAs top cell growth can cause the deterioration of the tunnel junction interconnect. In the approach of inverted-grown AlGaAs/GaAs cascade cells, the AlGaAs top cell is grown first at 780 [degree]C and the GaAs tunnel junction and bottom cell are grown at 675 [degree]C. After the inverted growth, the AlGaAs/GaAs cascade structure is selectively removed from the parent substrate. The feasibility of inverted growth is demonstrated by a fully-processed, inverted-grown, thin film GaAs cell with a 1-sun AM1.5 efficiency of 20.3%. Also, an inverted-grown, ...
1992-12-01
Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to ...
2002-03-01
This Dissertation presents the author's investigation and development of a systematic method for evaluating the aerodynamic performance of Vertical Axis Wind Energy Capture Systems (WECS) apart from their electrical generation capability. The current standard method for specifying a wind energy machine is to discuss its rated power in kilowatts (or megawatts when capacity exceeds 100 kW). While this holistic method is effective for comparing machines it does not reveal the essential characteristics necessary for optimization of individual machine components. The method developed herein separates the performance characteristics of the WECS from the generation characteristics and isolates them for benchmarking and optimization. In order to develop an evaluation criterion, it was essential to evaluate and benchmark the current state of the art for wind energy capture. A thorough history of Vertical Axis Wind Turbine (VAWT) development and technology transfer, a standardized set of VAWT ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The ...
2007-07-01
International Nuclear Information System (INIS)
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several ...
2006-07-01
A Clinical Study on the Value of a Scoring System of the Scanning Images in Liver Cirrhosis
International Nuclear Information System (INIS)
Although the radioisotope liver scan has primarily been of use in the detection of the intra-hepatic space occupying lesions, there has been an increasing awareness of its use in evaluation of liver function. In this study, the degree of hepatomegaly, changes in shape and mottling radiodensity on each lobe and splenic visualization in the liver scans done with colloidal radiogold were numerically expressed as scores under the arbitrary standard in 210 patients with liver cirrhosis. The clinical value of this scoring system was studied with special regards to the correlation between the radiogold hepatic uptake half time and conventional liver function tests. Following were the results; 1) The normal scan appeared in 6.7% of 210 patients with liver cirrhosis. 2) The colloidal radiogold hepatic uptake half time was abnormally and progressively prolonged in parallel to severity of hepatocellular dysfunction. The mean hepatic ...
1970-09-01
Special phased array applications for pipeline girth weld inspections
Energy Technology Data Exchange (ETDEWEB)
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for ...
2004-07-01
Prospective evaluation of femoral head viability following femoral neck fracture
International Nuclear Information System (INIS)
The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showed only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts ...
1984-06-05
Energy Technology Data Exchange (ETDEWEB)
A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...
1990-01-01
CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice
Energy Technology Data Exchange (ETDEWEB)
Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...
1992-07-15
CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice
International Nuclear Information System (INIS)
Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...
1992-07-01
Energy Technology Data Exchange (ETDEWEB)
The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their ...
1991-11-01
Turbulent heat transfer augmentation using microscale disturbances inside the viscous sublayer
Energy Technology Data Exchange (ETDEWEB)
The authors report here on an experimental study of heat transfer augmentation in turbulent flow. Enhancement strategies employed in this investigation are based on the near-wall mixing processes induced in the sublayer through appropriate wall and near-wall streamwise-periodic disturbances. Experiments are performed in a low-turbulence wind-tunnel with a high-aspect-ratio rectangular channel having either (a) two-dimensional periodic microgrooves on the wall, or (b) two-dimensional microcylinders placed in the immediate vicinity of the wall. It is found that microdisturbances placed inside the sublayer induce favorable heat-transport augmentation with respect to the smooth-wall case, in the near-analogous momentum and heat transfer behavior are preserved; a roughly commensurate increase in heat and momentum transport is termed favorable in that it leads to a reduction in the pumping power penalty at fixed heat removal rate. The study shows that this favorable ...
1992-05-01
Energy Technology Data Exchange (ETDEWEB)
A strong dependence of thermal activation energy (TAE) on infrared (IR) stimulation time for the infrared stimulated luminescence (IRSL) signal was observed for K-feldspar grains extracted from several sediments and granites from China. A TAE value as low as {approx}0.1 eV was observed at the beginning of IR stimulation and increased to {approx}0.45 eV after 90 s. For a trap depth of {approx}2 eV below the conduction band for the IRSL traps, the TAE value of {approx}0.45 eV is consistent with the energy gap between the excited states ({approx}0.5 eV below the conduction band) and conduction band. This phenomenon is explained as the result of the coexistence of thermally assisted recombination via conduction band or band-tail states hopping and athermal tunnelling recombination of electrons from the excited states under IR stimulation, leading to the observation of a higher anomalous fading rate in the initial part of the IRSL decay curve.
2010-08-15
Energy Technology Data Exchange (ETDEWEB)
Long-term disposal and management of low and intermediate-level radioactive waste is a major project of the nuclear power industry. Therefore, the selection of an underground waste repository has to be a geologically and seismologically stable storage. Easy transportation and emplacement is essential. The Wolsung nuclear power plant (NPP) of unit no. 1/2/ 3/ 4, which is responsible for the future of the energy industry, has already been constructed at the Wolsung site and a New NPP has recently been created at the Sinwolsung site. Radioactive waste used in the plant facilities, has piled up increasingly every year, but it should be taken to be managed at long-term underground storage disposal facilities. The Wolsung site for radioactivity waste repository was known to be relatively stable through various geological surveys, earthquakes, groundwater, engineering testing and analysis, but still more research related to the stability of the structure, in deep underground ...
2010-05-15
International Nuclear Information System (INIS)
Long-term disposal and management of low and intermediate-level radioactive waste is a major project of the nuclear power industry. Therefore, the selection of an underground waste repository has to be a geologically and seismologically stable storage. Easy transportation and emplacement is essential. The Wolsung nuclear power plant (NPP) of unit no. 1/2/ 3/ 4, which is responsible for the future of the energy industry, has already been constructed at the Wolsung site and a New NPP has recently been created at the Sinwolsung site. Radioactive waste used in the plant facilities, has piled up increasingly every year, but it should be taken to be managed at long-term underground storage disposal facilities. The Wolsung site for radioactivity waste repository was known to be relatively stable through various geological surveys, earthquakes, groundwater, engineering testing and analysis, but still more research related to the stability of the structure, in deep underground ...
2010-05-01
Energy Technology Data Exchange (ETDEWEB)
The danger potential for 110 kV cables, which are installed on racks and in tunnels, caused by catching fire because of arcing short circuits and mechanical overstressing by peak shortcircuit current, has been experimental analysed under Bewag network conditions. As a result, recommendations for an improved installation of 110 kV cables are given. (orig.) [Deutsch] Fuer offen gelegte 110-kV-Kabel in Raeumen, auf Fussboeden und in Schaechten wurde das von Kurzschluessen auf den Kabeln ausgehende Gefaehrdungspotential fuer die Entstehung von Kabelbraenden durch Fehlerlichtboegen und fuer eine mechanische Ueberbeanspruchung von Kabeln durch Stosskurzschlussstroeme unter Beruecksichtigung der Netzverhaeltnisse der Bewag experimentell untersucht. Im Ergebnis geben die Verfasser Empfehlungen fuer die sichere Anordnung offen gelegter 110-kV-Kabel. (orig.)
1998-03-23
Rhodopsin photochemistry is vibrationally coherent
Energy Technology Data Exchange (ETDEWEB)
Visual excitation is initiated by the absorption of a photon by the 11-cis retinal chromophore bound within the pigment called rhodopsin. We have used a variety of vibrational spectroscopies to obtain information about the vibrational nuclear dynamics that lead to this efficient photochemical isomerization. The cis-trans isomerization in rhodopsin is complete in only 200 fs. The extreme speed of this process, which is consistent with the {approximately}50 fs lifetime indicated by the spontaneous emission yield, suggests that the photochemistry involves non-stationary states or vibrational coherence. Recent studies have in fact observed vibrationally coherent oscillations of the ground state photoproduct called bathorhodopsin following impulsive excitation of the rhodopsin reactant. This conclusively demonstrates that the isomerization process in rhodopsin is vibrationally coherent. These observations further suggest that the isomerization quantum yield is directly dependent on the ...
1995-12-31
Recent trends in heavy-fermion physics
Energy Technology Data Exchange (ETDEWEB)
We discuss recent results obtained for the heavy-fermion metals UPd{sub 2}Al{sub 3} and YbRh{sub 2}Si{sub 2}. UPd{sub 2}Al{sub 3} is the first among all superconductors for which tunneling and inelastic neutron-scattering data highlight a non-phononic, i.e., magnetic-exciton mediated, pair state. YbRh{sub 2}Si{sub 2} represents a model system exhibiting pronounced non-Fermi liquid effects above a weak antiferromagnetic phase transition at T{sub N}=70 mK. Upon approaching the quantum critical point (T{sub N}{yields}0), by low doping with Ge, one observes for T<0.3 K disparate behavior in the temperature dependences of both the electrical resistivity and the electronic specific heat as well as a Curie-Weiss law in the uniform magnetic susceptibility, implying uncompensated large 4f moments. These observations indicate a break up of the composite quasiparticles into their local f-spin and itinerant conduction-electron parts.
2003-05-01
Proton spin lattice relaxation studies in lithium ammonium sulfate LiNH_4SO_4
International Nuclear Information System (INIS)
Lithium ammonium sulfate (LAS) undergoes a phase transition at Tsub(c1) = 459.5deg K from a paraelectric phase (phase 1) to a ferroelectric phase (phase II) and again at Tsub(c2) = 283deg K to a polar ferroelastic phase (phase III). Proton spin lattice relaxation investigations in the temperature range 480-77deg K at 10 MHz show discontinuous changes in Tsub(1) at the transition temperatures, indicating first order phase transitions. The absence of the slow motion region (#omega#sub(not)tausub(not)>>1) shows that the ammonium ions are reorienting fast enough to keep the resonance absorption line narrow down to liquid nitrogen temperatures. The possibility of a second minimum and a low activation energy, Esub(a) = 2.659 kcal/mole, in phase III suggest the possibility of tunnelling of the protons at low temperatures. The nature of the transitions have been discussed in the light of the available literature. The unusually high activation energy, Esub(a) = 17.845 ...
1978-12-31
Energy Technology Data Exchange (ETDEWEB)
The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general public. The action would also refurbish ...
1994-03-01
Probabilistic power generation planning with environmental consideration for Lebanon
International Nuclear Information System (INIS)
Full text.This paper describes a software tool for generation expansion planning based on dynamic programming, probabilistic production simulation, and environmental assessment. The aim is to determine the units needed to expand a given system in order to minimize either the cost or the environmental impact or some weighed function of the two. The problem of generation expansion planning is solved in stages using Tunnel Dynamic Programming (TDP) with Heuristic rules to limit the number of options analyzed. The production costing methodology is based on combining a probabilistic generation model known as the capacity outage table (COT) with the load duration curve (LDC) of the system to deduce a risk model from which the expected energy not supplied (EENS) is estimated. The generation model is built recursively using an efficient numerical convolution procedure and is combined at each step with the LDC to calculate the expected energy produced by each unit, its ...
2000-11-23
Energy Technology Data Exchange (ETDEWEB)
ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were proposed to extend the rectennas into the IR and optical region of the electromagnetic spectrum for use as ...
2003-02-01
Oxygen O18 method and the search for the ionization mechanism in sputtering of oxygenated surfaces
International Nuclear Information System (INIS)
Recently developed oxygen O18 method [K. Franzreb, J. Lorincik, P. Williams, Surf. Sci. 573 (2004) 291; R.C. Sobers, K. Franzreb, P. Williams, Appl. Surf. Sci. 231-232 (2004) 729; P. Williams, R.C. Sobers Jr., K. Franzreb, J. Lorincik, Appl. Surf. Sci. 252 (2006) 6429] is able to quantitatively determine the flux ratio of oxygen to matrix species at dynamical SIMS sputtering. This flux ratio can be directly related to the surface oxygen concentration at dynamical sputtering - an important parameter controlling the ionization yield of emitted species. It is argued that the oxygen O18 method is a worthy step forward in gathering relevant experimental data that might eventually lead to the understanding of oxygen enhancement mechanism in SIMS. A current status of understanding of the ionization processes in SIMS is briefly discussed in terms of non-adiabatic strongly velocity dependent processes represented by the electron tunneling and bond-breaking models and in ...
2008-12-15
Overview of the programme forseen for the potential site Oberbauenstock (Community Bauen UR)
International Nuclear Information System (INIS)
On 30th September 1985, the Federal Government licensed site suitability investigations in three areas with a view to disposal of low-and intermediate-level radioactive waste. This report gives a summary overview of the corresponding research programme at the potential site Oberbauenstock. The first part of the report begins with some comments on the concept of radioactive waste disposal and on some basic aspects of site-specific exploration and investigation. The governmental decision of 30th September and Nagra's two-phase investigation concept are then briefly considered. To close, the objectives of investigation phase I are outlined and possible results are briefly discussed. The research programme developed for investigation of the potential site at Oberbauenstock is presented in the second part of the report. Besides geological and hydrogeological investigations at the surface, the programme mainly comprises investigations and measurements in the underground structures of the ...
1985-09-01
On the theory of mechano-catalytic water-splitting system
Energy Technology Data Exchange (ETDEWEB)
A theory has been developed for the mechano-catalytic water-splitting, which is the system of simultaneous H{sub 2} and O{sub 2} evolution by stirring the powder of an oxide semiconductor in pure water under the condition that the stirring rod must be kept in contact with the surface of the glass vessel. The kinetic equations and the coupling strength of the frictional energy conversion between mechanical and electrical systems are calculated . The total system composed of the formation of the dangling bonds on the glass surface, the trapping of the semiconductor particles at the microcrevice of the glass surface, the strong field inside the fine particles due to the frictional electricity, the mechanism of charge transfer from the semiconductor to the stirring rod, the hopping conduction of positive hole, the electric current density injected into water from the semiconductors, and the tunnel chemical reaction for splitting-water have been analysed. Some parts of ...
2000-10-01
OECD/NEA international Stripa project 1980-1992. Overview volume 3
International Nuclear Information System (INIS)
The broad objective of the engineered barriers studies was to demonstrate and qualify the use of different materials and techniques for sealing water flow paths in the Stripa granite, the mine excavations and the excavation disturbed zones. As may be anticipated from the application of the observational method that forms the basis for design of geotechnical structures, the programme evolved with the finding being made at Stripa and other underground laboratories. During phase 1, the engineered barriers investigations focussed on the heat affected zone of the repository. Specifically, the response of clay buffers and the interactions between waste containers, clay buffer materials and the rock were studied. The phase 2 investigations examined the feasibility of sealing boreholes shafts and tunnels with clay sealants. The phase 3, studies of the ability to grout and seal fractured granite including the excavation disturbed zone were effected and specific studies into ...
Noise and microresonance of critical current in Josephson junction induced by Kondo trap states
We analyze the impact of trap states in the oxide layer of a superconducting tunnel junctions, on the fluctuation of the Josephson critical current, thus on coherence in superconducting qubits. Two mechanisms are usually considered: the current blockage due to repulsion at the occupied trap states, and the noise from electrons hopping across a trap. We extend previous studies of noninteracting traps to the case where the traps have on-site electron repulsion inside one ballistic channel. The repulsion not only allows the appropriate temperature dependence of 1/f noise, but also is a control to the coupling between the computational qubit and the spurious two-level systems inside the oxide dielectric. We use second order perturbation theory which allows to obtain analytical formulae for the interacting bound states and spectral weights, limited to small and intermediate repulsions. Remarkably, it still reproduces the main features of the model as identified from the ...
2011-01-01
The kinetics of electrical breakdown of thin (15-70 ?m) layers of polymers and ceramics in a constant-sign field at 77-480 K has been investigated. The temperature dependences of the longevity (breakdown waiting time) of both dielectrics have been found to be similar to each other. At elevated temperatures, the longevity of the dielectrics varies exponentially with increasing temperature, and at reduced temperatures, it is temperature-independent (there is an athermal plateau). The mechanisms of elementary events controlling the process of preparation of the dielectrics for breakdown at elevated and reduced temperatures are the thermal-fluctuation over-barrier electron transition from trap to trap and the tunneling (under-barrier) transition, respectively. The hopping electron transport in the field direction gives rise to critical space charges causing breakdown of the dielectrics. The transition barrier heights (trap depths) have been determined. The ...
2011-07-01
Lab-Tutorials for teaching quantum physics (Lab-Tutorials fuer den Quantenphysik Unterricht)
English abstract: In the "Intuitive Quantum Physics" course, we use graphical interpretations of mathematical equations and qualitative reasoning to develop and teach a simplified model of quantum physics. Our course contains three units: Wave physics, Development of a conceptual toolbox, and quantum physics. It also contains three key themes: wave-particle duality, the Schroedinger equation, and tunneling of quantum particles. Students learn most new material in lab-tutorials in which students work in small groups (3 to 3 people) on specially designed worksheets. Lecture reinforces the lab-tutorial content and focuses more on issues about the nature of science. Data show that students are able to learn some of the most difficult concepts in the course, and also that students learn to believe that there is a conceptually accessible structure to the physics in the course. German abstract: Im Kurs "Intuitive Quantum Physics" werden graphische Interpretationen ...
2006-01-01
International Nuclear Information System (INIS)
A nuclear fuel waste disposal vault would not likely be a sterile environment. Bacterial activity would be expected in those areas of the vault conducive to bacterial life, i.e., where effects of heat, moisture content, radiation and compaction would not prevent or severely restrict bacterial life and where suitable and sufficient nutrients would be present. An inventory of bacterial nutrients that would be emplaced 'intentionally' with vault materials (fuel waste, waste containers, buffer and backfill materials) has been made previously. This report assesses bacterial nutrients that would be added 'inadvertently' to a vault in the form of residues of materials used to excavate and operate a vault. Measurements of blasting material residues in the various water supplies, excavated broken rock (muck) and in cores drilled in old and new tunnel walls were made at AECL's Underground Research Laboratory. Results show that the largest potential nutrient addition (both ...
1987-08-27
Energy Technology Data Exchange (ETDEWEB)
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate oxide tunneling ...
2006-08-15
International Nuclear Information System (INIS)
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate oxide tunneling conduction ...
2006-08-01
High-efficiency solar cell and method for fabrication
A high-efficiency 3- or 4-junction solar cell is disclosed with a theoretical AM0 energy conversion efficiency of about 40%. The solar cell includes p-n junctions formed from indium gallium arsenide nitride (InGaAsN), gallium arsenide (GaAs) and indium gallium aluminum phosphide (InGaAlP) separated by n-p tunnel junctions. An optional germanium (Ge) p-n junction can be formed in the substrate upon which the other p-n junctions are grown. The bandgap energies for each p-n junction are tailored to provide substantially equal short-circuit currents for each p-n junction, thereby eliminating current bottlenecks and improving the overall energy conversion efficiency of the solar cell. Additionally, the use of an InGaAsN p-n junction overcomes super-bandgap energy losses that are present in conventional multi-junction solar cells. A method is also disclosed for fabricating the high-efficiency 3- or 4-junction solar cell by metal-organic chemical vapor deposition (MOCVD). ...
1999-08-31
High-efficiency GaAs solar cells on mm and sub-mm grain-size polycrystalline Ge substrates
Energy Technology Data Exchange (ETDEWEB)
GaAs material and device structure optimization studies on optical-grade, millimeter-and-less grain-size polycrystalline Ge substrates are presented. We discuss the growth of high-quality epitaxial layers across various crystalline orientations of a polycrystalline substrate; this is important for obtaining high-performance solar cells. The GaAs solar cell on n-type poly-Ge substrate is a p-on-n type, with an undoped spacer between the p-emitter and the n-base. An experimental study of dark currents in these junctions, with and without the spacer, as a function of temperature (77K to 288K) is presented; this study suggests that the spacer reduces the tunneling contribution to dark current. In addition, we describe device-structure optimization studies that have led us to achieve an open-circuit voltage (V{sub oc}) exceeding 1 Volt and an AM1.5 efficiency of {approximately}19{percent} for a 4-cm{sup 2}-area GaAs cell on sub-mm grain-size poly-Ge. We have also ...
1997-02-01
Energy Technology Data Exchange (ETDEWEB)
A central issue to be addressed within the Nevada Nuclear Waste Storage Investigations (NNWSI) is the role which fractures will play as the variably saturated, fractured rock mass surrounding the waste package responds to heating, cooling, and episodic infiltration events. Understanding the role of fractures during such events will, in part, depend on our ability to make geophysical measurements of perturbations in the moisture distribution in the vicinity of fractures. In this study we first examine the details of the perturbation in the moisture distribution in and around a fracture subjected to an episodic infiltration event, and then integrate that behavior over the scale at which moisture measurements are likely to be made during the Engineered Barrier Design Test of the NNWSI project. To model this system we use the TOUGH hydrothermal code and fracture and matrix properties considered relevant to the welded ash flow tuff found in the Topopah Spring member at Yucca Mountain as ...
1988-05-31
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation was conducted to evaluate the effect of three different oxygenated compounds, diglyme, diethyl maleate and dibutyl maleate, on emissions from a Volkswagen 1.9 litre, turbocharged, direct injection diesel engine. Sampling was performed using a mini-dilution tunnel technique to obtain particulate matter and a Fourier transform infrared (FTIR) spectrometer for gaseous emissions. The particulate samples were analysed using thermal analysis and Soxhlet extraction to determine the fraction of volatile and soluble organic material respectively. All three oxygenated compounds were found to be effective at reducing particulate emissions, with the maleate compounds being more effective overall than the diglyme. Analysis of the relative contributions of changes in the soot and soluble organic fraction (SOF) to the reduction of particulate matter indicated that, for diethyl maleate and diglyme, reductions in soot were the dominant effect. No ...
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
Rotationally resolved spectra of kinetic energy releases epsilon-c in predissociations of H/sub 2/, after dissociative charge exchange of H/sub 2/ /sup +/ with Cs atoms, are obtained. The experiments are performed with natural and with pure parahydrogen. The predissociations with epsilon-c<1.9 eV constitute less than 5% of the total amount of dissociations to HXchemically bondH at a beam energy of 5 keV. All strong rotational peaks observed could be attributed to n = 3 Rydberg states which predissociate to H(1s)+H(2l). Vibrational-rotational series are observed of the d /sup 3/Pi/sub u//sup +/, D /sup 1/Pi/sub u//sup +/, and J /sup 1/..delta../sub g//sup +/ states. Predissociation by barrier tunneling is reported of v = 4 levels of the h /sup 3/..sigma../sub g//sup +/ state and of v = 4 and 5 levels of the i /sup 3/Pi/sub g/ state. Selectivity of the charge-exchange process for different n = 3 states, or even for different parity states, is concluded.
1986-11-01
Energy Technology Data Exchange (ETDEWEB)
Acetohydroxyacid synthase (AHAS; EC 2.2.1.6) is the first enzyme in the biosynthetic pathway of the branched-chain amino acids. It catalyzes the conversion of two molecules of pyruvate into 2-acetolactate or one molecule of pyruvate and one molecule of 2-ketobutyrate into 2-aceto-2-hydroxybutyrate. AHAS requires the cofactors thiamine diphosphate (ThDP), Mg{sup 2+} and FAD for activity. The herbicides that target this enzyme are effective in protecting a broad range of crops from weed species. However, resistance in the field is now a serious problem worldwide. To address this, two new sulfonylureas, monosulfuron and monosulfuron ester, have been developed as commercial herbicides in China. These molecules differ from the traditional sulfonylureas in that the heterocyclic ring attached to the nitrogen atom of the sulfonylurea bridge is monosubstituted rather than disubstituted. The structures of these compounds in complex with the catalytic subunit of Arabidopsis thaliana AHAS have ...
2009-08-17
CAR International. A simple model to determine city street air quality
Energy Technology Data Exchange (ETDEWEB)
Based on wind tunnel experiments, theoretical considerations and measurements the dispersion model CAR (Calculation of Air pollution from Road traffic) has been developed for determining air quality in city streets. CAR International is a simple parameterized model using readily available input data and calculating annual percentile values and average concentrations close to streets (at the kerb side) for non-reactive air pollutants and NO{sub 2}. Originally the model was set up for the Dutch situation (traffic, meteorology) with a system of fixed parameters. In order to extend its application to other countries the program has been made more flexible and user friendly. User defined system data can now be changed interactively, such as emission factors of passenger cars and trucks, fraction of directly emitted NO{sub 2}, city and regional background concentration, and average regional wind speed. The accuracy of the model has proved to be good and is within the ...
1995-06-22
Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite
Energy Technology Data Exchange (ETDEWEB)
The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, the AF of the BSL and IRSL is stronger ...
2006-08-15
Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite
International Nuclear Information System (INIS)
The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, the AF of the BSL and IRSL is stronger ...
2005-07-24
An Empirical Analysis of Internet Protocol Version 6 (IPv6)
Although the current Internet Protocol known as IPv4 has served its purpose for over 20 years, its days are numbered. With IPv6 reaching a mature enough level, there is a need to evaluate the performance benefits or drawbacks that the new IPv6 protocol will have in comparison to the well established IPv4 protocol. Theoretically, the overhead between the two different protocols should be directly proportional to the difference in the packet's header size, however according to our findings, the empirical performance difference between IPv4 and IPv6, especially when the transition mechanisms are taken into consideration, is much larger than anticipated. We first examine the performance of each protocol independently. We then examined two transition mechanisms which perform the encapsulation at various points in the network: host-to-host and router-to-router (tunneling). Our experiments were conducted using two dual stack (IPv4/IPv6) routers using end nodes running ...
2004-01-01
Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring
Energy Technology Data Exchange (ETDEWEB)
This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' performed by SKB staff. This document provides an in-depth summary of the AE and ...
2005-12-15
Aerodynamic force measurement on a large-scale model in a short duration test facility
International Nuclear Information System (INIS)
A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between measured values and numerical simulation values was less than 5%. We conclude that this measurement technique is sufficiently reliable for measuring aerodynamic force ...
2005-03-01
Aerodynamic design of the George Washington University solar car Sunforce 1
Energy Technology Data Exchange (ETDEWEB)
Aerodynamics play a critical role in the success of a competitive solar vehicle. In particular, the topics addressed in this paper are minimizing the drag forces acting on the car surface while providing an effective angle of solar exposure, ventilation, manoeuvring stability, maintenance accessibility, and component `functional duality`, while simultaneously maintaining stringent racing regulations. Starting with a conceptual design, modifications were analysed through a commercial, computational fluid dynamics (CFD) package in order to evaluate drag and lift characteristics. By visualizing wind tunnel flow as a means of support of the coded model, the computational design has been validated. Although the design of the George Washington University (GWU) solar car `Sunforce 1` was geared towards the November 1993 World Solar Challenge held in Australia, results of the fourth place finish in the US Sunrace `93 were used to demonstrate the effectiveness of this ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
Anomalous fading of the feldspar infrared stimulated luminescence (IRSL) signal hampers possibilities of using feldspar IRSL to obtain burial ages for sediments beyond the dating range of quartz optically stimulated luminescence. Here, we propose a new approach to quantify anomalous fading of the feldspar IRSL signal over geological burial times based on laboratory fading experiments. The approach builds on the description of the quantum mechanical tunnelling process recently proposed by Huntley [2006. An explanation of the power-law decay of luminescence. J. Phys. Condensed Matter 18, 1359-1365]. We show that our methods allow the construction of un-faded and natural IRSL dose-response curves as well as anomalous fading rates in field saturation. The predicted level of field saturation closely approximates the measured saturation level for five samples from fluvial deposits (Lower Rhine) known to be older than 1 Ma. The modelled anomalous fading rate in field ...
2008-02-15
(Electronic and structural properties of individual nanometer-size supported metallic clusters)
Energy Technology Data Exchange (ETDEWEB)
The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their ...
1991-11-01
Energy Technology Data Exchange (ETDEWEB)
Step-scan Fourier transform infrared spectroscopy in conjunction with impulse stress on polymer films has been used to monitor dynamic rheological responses in real time. A novel piezo-electrically-driven polymer microrheometer was employed to apply repetitive impulses to the polymer sample while time-domain spectra were recorded. Recent results include the study of both semi-crystalline polymers such as isotactic polypropylene (iPP) and elastomers such as Estane polyester/polyurethane copolymer and Kraton tri-block copolymer. The spectral changes of iPP are consistent with frequency-domain results. For iPP at room temperature, large differences in the response times of different absorption bands are not seen. However, the orientation response of the CH{sub 3} rocking mode is slightly slower than the responses of the backbone modes. To the authors` knowledge, this is the first reported successful step-scan FTIR time-domain dynamic polymer ...
1998-07-01
The uterine blush. A potential false-positive in Meckel's scan interpretation
Energy Technology Data Exchange (ETDEWEB)
To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. ...
1982-10-01
Energy Technology Data Exchange (ETDEWEB)
We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.
1997-10-01
International Nuclear Information System (INIS)
We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.
1988-09-18
Position of nuclear-medical techniques for evaluation of loosened total hip endroprostheses
Energy Technology Data Exchange (ETDEWEB)
For diagnosis of loosening or infection after implantation of a single-side or double-side total hip endoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled leucocyte ...
1985-10-01
Energy Technology Data Exchange (ETDEWEB)
Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to ...
1989-12-15
Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin
Energy Technology Data Exchange (ETDEWEB)
The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled ...
1990-12-01
High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control
Energy Technology Data Exchange (ETDEWEB)
High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing ...
2004-03-31
Ganglioneuromas in childhood: MRI and CT characteristics
International Nuclear Information System (INIS)
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...
2000-05-01
Dimensionless energy confinement scaling in W7-AS
International Nuclear Information System (INIS)
Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is ...
1999-12-01
Computed tomography of the orbit
Energy Technology Data Exchange (ETDEWEB)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...
1981-01-01
Computed Tomography in pulmonary cystic fibrosis
International Nuclear Information System (INIS)
This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...
1984-11-01
3-dimensional observations of atmospheric variables during the field campaign COPS
Energy Technology Data Exchange (ETDEWEB)
The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman lidar which provides combined ...
2008-05-01
[75Se]Selenomethionine scanning for parathyroid localization should be abandoned
International Nuclear Information System (INIS)
Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in the preoperative ...
Vessel elements present in the secondary xylem of Trochodendron and Tetracentron (Trochodendraceae)
British Library Electronic Table of Contents (United Kingdom)
For almost 150 years, the two monotypic genera Trochodendron and Tetracentron (Trochodendraceae) have been considered to share an unusual and primitive feature in angiosperms - the lack of vessels in their wood. Therefore, they have been classified in a basal position in the angiosperms. Our observations by light microscopy, low-vacuum environmental scanning electron microscopy (ESEM) and high-vacuum scanning electron microscopy (SEM) both in fresh and FAA-fixed materials consistently showed the presence of tracheary elements differentiated into two types in both genera. In Trochodendron, the tracheary elements can be divided into perforate vessel elements and imperforate fiber-tracheids and tracheids. The vessel elements show end and lateral walls. The pits on the end walls are elongate- ...
2011-01-01
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.
2003-05-01
British Library Electronic Table of Contents (United Kingdom)
Direct visualization of rare earths in @a- and @b-SiAlON unit-cells is performed through Z-contrast imaging technique in an aberration-corrected scanning transmission electron microscope. The preferential occupation of Yb and Ce atoms in different interstitial locations of @b-SiAlON lattice is demonstrated, yielding higher solubility for Yb than Ce. The triangular-like host sites in @a-SiAlON unit cell accommodate more Ce atoms than hexagonal sites in @b-SiAlON. We think that our results will be applicable as guidelines for many kinds of rare-earth-doped materials.
2011-01-01
Thermal and mechanical properties of poly(vinyl alcohol) plasticized with glycerol
British Library Electronic Table of Contents (United Kingdom)
Abstract Thermomechanical behavior of membranes based on blends of poly(vinyl alcohol) (PVA) with different weight percentage (wt %) of glycerol has been studied. Solid-state PVA/Glycerol polymer membranes were prepared by a solution casting method. The films were studied for thermal characteristics by differential scanning calorimetry (DSC) and thermogravimetric analysis and for the mechanical properties including hardness and modulus by nanoindentation method. The dispersion of glycerol within the polymer matrix was examined using scanning electron microscopy. Fourier transform infrared spectroscopy was used to confirm the formation of hydrogen bonding between the plasticizer and PVA in their blends and also to provide information on compatibility and physical interactions between the gl...
2011-01-01
Subdural effusions in children under two years. Clinical and computer-tomographical data
Energy Technology Data Exchange (ETDEWEB)
We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.
1980-05-01
British Library Electronic Table of Contents (United Kingdom)
Chitosan (Ch) microspheres have been developed by precipitation method, cross-linked with glutaraldehyde and used as a template for layer-by-layer (LBL) deposition of two natural polyelectrolytes. Using a LBL methodology, Ch microspheres were alternately coated with hyaluronic acid (HA) and Ch under mild conditions. The roughness of the Ch-based crosslinked microspheres was characterized by atomic force microscopy (AFM). Morphological characterization was performed by environmental scanning electron microscopy (ESEM), scanning electron microscopy (SEM) and stereolight microscopy. The swelling behaviour of the microspheres demonstrated that the ones with more bilayers presented the highest water uptake and the uncoated cross-linked Ch microspheres showed the lowest uptake capability. Micros...
2010-01-01
Precise measurement of a focused ion beam profile
Energy Technology Data Exchange (ETDEWEB)
The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.
1987-06-01
Polarised neutron reflectometry study of Co/CoO exchange-biased multilayers
Energy Technology Data Exchange (ETDEWEB)
We have investigated via SQUID magnetometry and polarised neutron reflectivity the exchange-bias effect in CoO/Co sputtered multilayers. In particular, we studied the magnetisation reversal and the time relaxation of the exchange-bias field close to the coercive field H{sub c1}. Neutron intensities of all four cross sections (I++, I+-, I-+, I-) were recorded at the position of the first multilayer Bragg peak while scanning the magnetic field. From such scans we infer that the magnetisation reversal for the ascending as well as for the descending branch of the magnetic hysteresis occurs not by in-plane rotation but through domain-wall movements. The exchange-bias field, H{sub EB}, is strongly affected by thermal fluctuations. H{sub EB} decreases, following an exponential decay function with a half-life time of about 580 s at T=240 K. (orig.)
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution and coverage of the ...
2000-11-01
Neutron intensity measurements of BWR spent fuels
International Nuclear Information System (INIS)
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
2000-03-01
Miscibility enhancement of PP/PBT blends with a side-chain liquid crystalline ionomer
British Library Electronic Table of Contents (United Kingdom)
Side-chain liquid crystalline ionomer (SLCI) containing sulfonic acid groups with a polymethylhydrosiloxane main-chain was used in the blends of polypropylene (PP) and polybutylene terephthalate (PBT) as a compatibilizer. The crystalline behavior, morphological, and mechanical properties of the blends were investigated in detail by differential scanning calorimetry (DSC), polarizing optical microscope (POM), Fourier transforms infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Revealed by the shift of Tm in DSC thermogram and the shift of the absorbed peak in FTIR spectra, specific interaction led to stronger interfacial adhesion between these phases, which resulted in much finer dispersion of the minor PBT phase in PP matrix. The SLCI containing sulfonate acid groups ac...
2009-01-01
Mechanism of filler action in reducing the wear of PTFE polymer by differential scanning calorimetry
British Library Electronic Table of Contents (United Kingdom)
Two types of representative nanometer materials, i.e., fibroid nanometer attapulgite and approximate spherical ultrafine diamond, were selected as fillers of polytetrafluoroethylene (PTFE) to study the mechanism of the wear-reducing actions of the fillers in PTFE composites. The friction and wear tests were performed on a block-on-ring wear tester under dry sliding conditions. Differential scanning calorimetry (DSC) was used to investigate material microstructure and to examine modes of failure. No significant change in coefficient of friction was found, but the wear rate of PTFE composites was orders of magnitude less than that of pure PTFE. DSC analysis revealed that nanometer attapulgite and ultrafine diamond played a heterogeneous nucleation role in PTFE matrix and consequently resulte...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)
1997-05-01
Impact of Cr3C2/VC addition on the dry sliding friction and wear response of WC-Co cemented carbides
British Library Electronic Table of Contents (United Kingdom)
Two grades of WC-10wt.%Co cemented carbide with or without addition of Cr3C2/VC grain growth inhibitor during liquid phase sintering were produced with the goal to investigate their reciprocating sliding friction and wear behaviour against WC-6wt.%Co cemented carbide under unlubricated conditions. The tribological characteristics were obtained on a Plint TE77 tribometer using distinctive normal contact loads. The generated wear tracks were analyzed by scanning electron microscopy and quantified topographically using surface scanning equipment. The post-mortem obtained wear volumes were compared to the online assessed wear. Correlations between wear volume, wear rate and coefficient of friction on the one hand and sliding distance and microstructural properties on the other hand were determ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.
1988-01-01
Focused ion beam sculpting curved shapes.
Energy Technology Data Exchange (ETDEWEB)
A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.
2005-02-01
Finite element analysis of a scanning x-ray microscope micropositioning stage
Energy Technology Data Exchange (ETDEWEB)
A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.
1992-01-01
Extracellular matrix of plant callus tissue visualized by ESEM and SEM
British Library Electronic Table of Contents (United Kingdom)
Actinidia deliciosa endosperm-derived callus culture is stable over a long period of culture. This system was used to investigate the ultrastructure of extracellular matrix occurring in morphogenic tissue. Specimens were prepared by different biological techniques (chemical fixation, liquid nitrogen fixation, glycerol substitution, critical-point drying, lyophilization) and observed by scanning electron microscopy (SEM). Fresh and wet samples were analyzed with the use of environmental scanning electron microscopy (ESEM). Extracellular matrix was observed on the surface of cell clusters as a membranous layer or reticulated network, shrunken or wrinkled, depending on the procedure. Generally, shrunken membranous layers with a globular appearance and fibrils were noted after critical-point d...
2010-01-01
Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry
British Library Electronic Table of Contents (United Kingdom)
Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...
2010-01-01
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
British Library Electronic Table of Contents (United Kingdom)
Abstract Here we propose a software for the estimation of the occupied area and volume of fungal cultures. This software was developed using a Matlab platform and allows analysis of high-definition images from optical, electronic or atomic force microscopes. In a first step, a single hypha grown on potato dextrose agar was monitored using optical microscopy to estimate the change in occupied area and volume. Weight measurements were carried out to compare them with the estimated volume, revealing a slight difference of less than 1.5%. Similarly, samples from two different solid-state fermentation cultures were analyzed using images from a scanning electron microscope (SEM) and an environmental SEM (ESEM). Occupied area and volume were calculated for both samples, and the results obtained w...
2011-01-01
International Nuclear Information System (INIS)
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
Electrical properties of focused-ion-beam boron-implanted silicon
International Nuclear Information System (INIS)
Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).
Effects of modification on microstructure and properties of ultrahigh carbon (1.9wt.% C) steel
British Library Electronic Table of Contents (United Kingdom)
The effects of a modifier that contains Rare Earths (RE), low melting point alloy (Al-Bi-Sb) and Ca-Si alloy on an ultrahigh carbon steel containing 1.9wt.% C were studied. Microstructure characterization was carried out with optical microscopy (OM) and scanning electronic microscopy (SEM) combined with energy-dispersive spectrometry (EDS). Upon modification, the continuous eutectic carbide network structure was broken up and changed to a partly isolated and finer blocky structure in the as-cast alloy. Differential scanning calorimetry (DSC) revealed that the eutectoid temperature increased and the eutectic temperature decreased for the modified alloy. Modification also improved the impact toughness of the tempered steel, with a significant increase from 6.5 to 12.6Jcm^-^2, despite the har...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
To improve the friction and wear behavior of carbon fabric reinforced polymer composites (CFRP), nano-SiO2 was deposited on the fabric surface. The friction and wear behavior of the resulting composites were investigated on a model ring-on-block test rig. Experimental results revealed that fiber surface treatment contributed to largely improve the tribological properties of the CFRP composites. Scanning electron microscope (SEM) investigation showed that the worn surface of the surface modified CFRP composite was smoother under given load and sliding rate. Field emission scanning electron microscopy (FESEM), FTIR and X-ray photoelectron spectroscopy (XPS) studies of the carbon fiber surface showed that nanostructured Sio2 thin film can be obtained by SiO2 sols deposition, which improved th...
2009-01-01
International Nuclear Information System (INIS)
Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)
1998-10-30
British Library Electronic Table of Contents (United Kingdom)
A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...
2011-01-01
Characterisation and use of biomass fly ash in cement-based materials
British Library Electronic Table of Contents (United Kingdom)
This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...
2009-01-01
For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817
1999-03-20
Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics
International Nuclear Information System (INIS)
Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.
International Nuclear Information System (INIS)
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
We have employed Environmental Scanning Electron Microscopy (ESEM) and Energy Dispersive X-ray (EDX) analysis to study the microstructural evolution of acrylic latex stabilised with a novel polysaccharide derived from agricultural waste. The analysis revealed that the micro structure of the latex in the 'wet' state consists of individual particles and clusters. Upon evaporation a discontinuous film is formed, with voids present within its structure, which is inconsistent with the conventional descriptions of film formation. Further ESEM examination of 'dry' specimens revealed that aging resulted in the formation of dendritic structures on the surfaces of the latex films, which EDX analysis confirmed to have been formed via crystallisation of salt. The experimental evidence suggests that the clusters, which are part of the structure of the latex, may act as nucleation centres that would allow the dendrites to form.
2008-08-15
A novel gamma scanning system for on-line diagnostic inspection of industrial process columns
International Nuclear Information System (INIS)
A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)
A mobile gamma scanning system for detecting radiation anomalies
Energy Technology Data Exchange (ETDEWEB)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
1983-09-01
A mobile gamma scanning system for detecting radiation anomalies
International Nuclear Information System (INIS)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
A digitization and multimedia project at Quinnipiac University, Hamden, Connecticut, USA
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...
2007-01-01
Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT
Energy Technology Data Exchange (ETDEWEB)
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse ...
2000-08-01
VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
Thermal NDE method for thermal spray coatings
Energy Technology Data Exchange (ETDEWEB)
This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.
1982-01-01
UK PubMed Central (United Kingdom)
The interpretation of solution hydrodynamic data in terms of macromolecular structural parameters is not a straightforward task. Over the years, several approaches have been developed to cope...Full Text Available
2010-02-01
Energy Technology Data Exchange (ETDEWEB)
The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did ...
1988-12-01
Regulatory T cells inhibit stable contacts between CD4+ T cells and dendritic cells in vivo
UK PubMed Central (United Kingdom)
Regulatory T (T reg) cells exert powerful down-modulatory effects on immune responses, but it is not known how they act in vivo. Using intravital two-photon laser scanning microscopy we determined that,...Full Text Available
2006-03-20
Radioisotope imaging of brain tumors in two rhesus monkeys. Final report
Energy Technology Data Exchange (ETDEWEB)
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
1988-04-01
International Nuclear Information System (INIS)
Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)
1999-10-26
Personal computers restructuring tomorrow's nets
Energy Technology Data Exchange (ETDEWEB)
Discusses alternative futures for distributing future personal computers, via data communications networks. The author scans and extrapolates some of the advances for impacting the emerging future of information utilities now sprouting up thoroughout the world. In particular he looks at the future of personal computers in the field of artificial intelligence,, for expert knowledge-based systems.
1982-01-01
Molecules with polymerizable ligands as precursors to porous doped materials
Energy Technology Data Exchange (ETDEWEB)
Titanium and aluminum alkoxide derivatives with polymerizable ligands such as 2-(methacryloyloxy)ethylacetoacetate (HAAEMA), oleic acid and geraniol (HOGE) have been obtained. The various compounds have been characterized by FT-IR and NMR {sup 1}H. Copolymerization with styrene and divinylbenzene affords porous doped organic materials which have been characterized by scanning electron microscopy (SEM), elemental analysis, density measurements.
1996-12-31
Micromachining using focused ion beams
Energy Technology Data Exchange (ETDEWEB)
Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)
1994-11-16
International Nuclear Information System (INIS)
Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median MRI slice was rated ...
2007-02-01
Fouling Study of Silicon Oxide Pores Exposed to Tap Water
Energy Technology Data Exchange (ETDEWEB)
We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.
2007-07-12
Fault diagnosis of rolling bearing based on cyclic spectrum density
International Nuclear Information System (INIS)
The paper considered the vibration signals of rotating equipment as cyclo stationary signals through analyzing the features of this kind of signals. Based on the analytic method of cyclic spectrum density, the paper pointed out that the impact frequency could be extracted effectively with the help of scanning cyclic frequency domain. The validity of the method of cyclic spectrum density is proved by simulating signals and the method is applied to the diagnosis of rolling bearings. (authors)
2009-09-01
Electrochemical stability of silicon/carbon composite anode for lithium ion batteries
International Nuclear Information System (INIS)
Silicon/carbon composite anode materials were prepared by pyrolyzing the phenol-formaldehyde resin (PFR) mixed with silicon and graphite powders. Scanning electron microscopic (SEM) observation showed that the morphology stability of the composite electrodes can be retained during cycling. A structure evolution mechanism is proposed to illuminate the enhancement of cycleability of the composite electrode. The composite used as anode material for lithium ion batteries possesses a reversible capacity of over 700 mAh/g.
2007-04-20
Effect of environmental variables on localized corrosion of high-performance container materials
Energy Technology Data Exchange (ETDEWEB)
Electrochemical cyclic potentiodynamic polarization (CPP) experiments were performed on several candidate high-performance waste package container materials to evaluate their susceptibility to localized corrosion in aqueous environments relevant to the potential underground high-level nuclear waste repository. This paper presents the results of this study showing the effects of chloride ion (Cl) concentrations, pH, temperature, and electrochemical potential scan rate on the pitting corrosion behavior of these materials.
1997-01-01
Differential diagnosis of tumorous lesions in the iliac bone in children
Energy Technology Data Exchange (ETDEWEB)
The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.
1984-02-01
Dielectric barrier discharge using corona-modified silicone rubber
Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.
2008-10-01
Development and application of a gamma scanning system for LLW and MLW packages
International Nuclear Information System (INIS)
The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.
1993-09-05
UK PubMed Central (United Kingdom)
CTX-M extended-spectrum beta-lactamases (ESBLs) have emerged as the most common type of ESBL globally, their incidence easily surpassing those of SHV and TEM ESBLs in most locales. This study compared...Full Text Available
2010-01-01
Data of spleen-scintiscanning after splenectomy
International Nuclear Information System (INIS)
In 65 adult rabbits of both sexes (2.5 to 6 kg) the following salvaging procedures were performed after simulated trauma: (1) Continuous suture line; (2) closure with fibrin sealant after temporary clamping; (3) hemisplenectomy with omental wrap; (4) suture fixation of fragments and slices of spleen tissue to the peritoneum; (5) suture fixation of spleen fragments to the omentum; (6) extraperitoneal subcutaneous transposition of spleen cubes. In addition, the likelihood of spontaneous splenosis was examined in a preliminary study involving 5 animals by introducing unattached spleen meal and fragments. Scanning was repeated 4 to 12 weeks postoperatively. The functional competence of minor parenchymal islands was also investigated with well counter measurements of organ and muscle tissue homogenates. Spontaneous splenosis after abdominal injuries was not found to be the rule. Salvaging procedures at the natural vascular hilus by sutures, fibrin sealant and ...
Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method
Energy Technology Data Exchange (ETDEWEB)
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
1982-01-01
CT scan findings in cerebral paragonimiasis
International Nuclear Information System (INIS)
Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
1982-01-01
CT manifestations of ileal dysgenesis
Energy Technology Data Exchange (ETDEWEB)
Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)
2007-02-15
Biodegradability of polyurethane/polysaccharide blends
Energy Technology Data Exchange (ETDEWEB)
Biodegradable polymers for use in environmental waste-management has been the subject of much discussion over the last few years. Polyurethane mixtures with polysaccharide (80/20 and 90/10 w/w ) have been prepared and films obtained. These films were inoculated, according to ASTM G22-76 rule and analysed by thermogravimetry and scanning electronic microscopy (SEM). The results are discussed in terms of thermal degradation and biodegradability. (author)
2001-07-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
International Nuclear Information System (INIS)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the ...
2009-03-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the ...
2007-06-15
A study of the effect of Yttria additions on densification of #beta#-sialon
International Nuclear Information System (INIS)
In this paper the effect of adding commercially pure yttria concentrate and yttrium carbonate concentrate (NUCLEMON) on the densification of #beta#-Sialon has been studied. The specimens were sintered in graphite furnace at 1720 and 175 deg C, for 1 hour in a nitrogen atmosphere. Densities of up to 99% of the theoretical density were obtained. Microstructural analyses of the specimens were carried out with the aid of an X ray diffractometer and a scanning electron microscope. (author)
1995-06-10
Application of low-dose radiation protocols in survey CT scans
International Nuclear Information System (INIS)
Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for ...
2009-08-01
Energy Technology Data Exchange (ETDEWEB)
Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...
2009-10-15
Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method
Energy Technology Data Exchange (ETDEWEB)
High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width of the ribbon, with far greater speed, lower cost, and more ...
1993-08-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...
2008-10-01
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral formation in this ...
2011-05-05
Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys
International Nuclear Information System (INIS)
Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial ...
2006-08-30
International Nuclear Information System (INIS)
Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal findings can therefore exclude the ...
1988-08-15
International Nuclear Information System (INIS)
Two most important causes of portal hypertension are cirrhosis of liver and non-cirrhotic portal fibrosis (NCPF). The purpose of this study was to assess the scintigraphic appearances of "9"9"mTc sulfur colloid liver scan in differentiating liver cirrhosis from NCPF. Materials and Methods: Retrospective analysis records of 146 patients (91 male and 55 female) with diffuse hepatocellular disease was done for liver size, liver uptake, spleen size, spleen uptake, colloid shift to bone marrow and lungs. Results: Cirrhotic livers showed patchy and lower uptake than NCPF (59% vs. 20%, P-value 0.041). Spleen size was significantly increased in NCPF compared to cirrhosis (100% vs. 67%, P-value 0.0137). Significant colloid shift to bone marrow was noted in cirrhosis (84% vs. 7%, P-value<0.0001). Conclusion: "9"9"mTc sulfur colloid liver scan is a non-invasive procedure having a useful adjunctive role in clinical differentiation of cirrhosis from ...
International Nuclear Information System (INIS)
Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.
International Nuclear Information System (INIS)
This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more reliable results. Furthermore, the results are compared to the ...
2011-06-01
International Nuclear Information System (INIS)
Thermochromic tungsten-doped vanadium dioxide (VO2) powders were successfully synthesized by thermal reduction using V2O5 as a vanadium precursor. The products were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and differential scanning calorimetry (DSC). The results indicated that W was successfully doped into the crystal lattice of VO2 matrix, and prepared tungsten-doped VO2 had a rod-like morphology. The effects of reducing temperature and annealing temperature on the crystallographic structures were also discussed. The phase transition temperature (Tt) of VO2 could be simply tuned by changing the doping concentration of tungsten. When the doping concentration was 1.58 mol%, the Tt could be reduced to 37.8 oC from initial 69.5 oC, suggesting that tungsten-doped VO2 possesses prominent thermochromic properties and optical switching characters. It has shown that this ...
2010-08-20
Preparation of ZnO varistors by solution nano-coating technique
Energy Technology Data Exchange (ETDEWEB)
This paper introduces a new method to produce nano-composite powder for the preparation of high performance ZnO varistors. ZnO particles were coated with Bi{sub 2}O{sub 3}, Sb{sub 2}O{sub 3}, Co{sub 2}O{sub 3}, Cr{sub 2}O{sub 3} and other additives via liquid nano-coating technique. Then the prepared powder was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), thermal gravity and differential scanning calorimetry (TG-DSC) and particle size distribution. The results showed that the ZnO composite powder is homogeneously coated and ultrafine. The densification, phase composition and microstructure of ZnO varistors was studied by linear shrinkage, X-ray diffraction (XRD) and SEM, respectively. The preliminary electrical parameters of ZnO varistors showed that the breakdown voltage V {sub b} (1 mA/cm{sup 2}) and nonlinear coefficient {alpha} is 5400 V/cm and 50, respectively, much higher than that of ...
2006-06-15
Energy Technology Data Exchange (ETDEWEB)
One- and two-dimensional long-period superstructures (LPS), based on the L1{sub 2} substructure, are systematically investigated for the noble metal-palladium alloys Cu-Pd, Ag-Pd and Au-Pd with first-principles methods. Notwithstanding the fact that the experimental phase diagrams of these systems yield totally different features, quite similar behaviour with respect to formation of low temperature ordered LPS-phases (Cu{sub 3}Pd: LPS 3, Ag{sub 3}Pd: LPS 3, Au{sub 3}Pd: LPS 2; {l_brace}Cu, Au{r_brace}Pd{sub 3}: L1{sub 2}, AgPd{sub 3}: not a ground state) is predicted. As a lever between via LDA obtained formation enthalpies and a thorough ground state scan, the cluster expansion method in conjunction with a genetic algorithm provides adequate means for the extraction of effective interactions, which also allow for an enhanced ground state scan in the configurational space of LPS structures. As a result, the sequences and energetical hierarchies ...
2007-07-01
International Nuclear Information System (INIS)
Iron oxide thin films were prepared by spray pyrolysis technique onto glass substrates from iron chloride solution. They were characterized by X-ray diffractometry (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and (UV-vis) spectroscopy. The films deposited at T _s #<=# 450 deg. C were amorphous; while those produced at T _s_u_b = 500 deg. C were polycrystalline #alpha#-Fe_2O_3 with a preferential orientation along the (1 0 4) direction. By observing scanning electron microscopy (SEM), it was seen that iron oxide films were relatively homogeneous uniform and had a good adherence to the glass substrates. The grain size was found (by RX) between 19 and 25 nm. The composition of these films was examined by X-ray photoelectron spectroscopy and electron probe microanalysis (EPMA). These films exhibited also a transmittance value about 80% in the visible and infrared range. The cyclic voltammetry study showed ...
2006-12-15
Pelvic CT for the prognostic evaluation of anorectal malformation
International Nuclear Information System (INIS)
The anatomical patterns of anorectal malformations have so far been studied according to the principles which inspire Pena's technique for the surgical treatment of anorectal anomalies. Thus, the diagnostic study of anorectal malformation has by the authors been considered a work of classification, but of identification. Among the diagnostic procedures in use in author's Institute, preoperative CT of pelvis is performed to assess the presence and to define the development of muscular sphincteric structure towards prognostic evaluation of continence, the major long-term goal. Seven patients, aged 1-30 months, with anorectal anomalies were studied with preoperative CT of the pelvis. CT scans showed well-developed sphinteric muscles in 3 patients (2 with recto-ureteral and 1 with recto-vestibular fistulas), poorly-developed muscular structure in 3 patients (with recto-vaginal, cloacal and prostatic fistulas), absence of muscular structure in 1 case (with recto-vesical ...
1989-01-01
Optimal alignment of mirror based pentaprisms for scanning deflectometric devices
In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction of the systematic ...
2011-03-04
Energy Technology Data Exchange (ETDEWEB)
The ultrafine fibers based on the composites of polyethylene terephthalate (PET) and a series of fatty acids, lauric acid (LA), myristic acid (MA), palmitic acid (PA), and stearic acid (SA), were prepared successfully via electrospinning as form-stable phase change materials (PCMs). The morphology and thermal properties of the composite fibers were studied by field emission scanning electron microscopy (FE-SEM) and differential scanning calorimetry (DSC), respectively. It was found that the average fiber diameter increased generally with the content of fatty acid (LA) in the LA/PET composite fibers. The fibers with the low mass ratio maintained cylindrical shape with smooth surface while the quality became worse when the mass ratio is too high (more than 100/100). Moreover, the latent heat of the composite fibers increased with the increase of LA content and the phase transition temperature of the fibers have no obvious variations compared with ...
2008-11-15
Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloy
International Nuclear Information System (INIS)
Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloys with 0#<=#x#<=#1 have been performed. The simulations are compared with measured channeling-angular scans for strained Si_0_._9_5Sn_0_._0_5 layers grown by molecular beam epitaxy (MBE). Agreement between simulated and measured angular scans can only be achieved if we assume a deviation of the crystal structure from the ideal one. This deviation can be attributed to a mosaic structure in the films and to an atomic-scale distortion of the crystal lattice due to an expected difference in the bond lengths between the Si-Si, Si-Sn and Sn-Sn atoms (such a difference in bond lengths has been observed in the epitaxial Si_1_-_xGe_x system). The contributions from both of these imperfections are estimated and discussed.
2000-04-01
Modification of SGS system for application to various sized drums
Energy Technology Data Exchange (ETDEWEB)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...
2005-11-15
Modification of SGS system for application to various sized drums
International Nuclear Information System (INIS)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The accuracy of TGS is better ...
2005-11-01
MicroDiffraction in the Scanning Electron Microscope (SEM)
The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and elemental information to ...
1997-12-31
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
Energy Technology Data Exchange (ETDEWEB)
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform infrared (FTIR) spectroscopic analysis, ...
2011-01-15
Intrapartum FHR monitoring and neonatal CT brain scan
Energy Technology Data Exchange (ETDEWEB)
The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and ...
1982-12-01
Intrapartum FHR monitoring and neonatal CT brain scan
International Nuclear Information System (INIS)
The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and no variability resulted in ...
1982-01-01
High resolution scanning electron microscopy of plasmodesmata.
Symplastic transport occurs between neighbouring plant cells through functionally and structurally dynamic channels called plasmodesmata (PD). Relatively little is known about the composition of PD or the mechanisms that facilitate molecular transport into neighbouring cells. While transmission electron microscopy (TEM) provides 2-dimensional information about the structural components of PD, 3-dimensional information is difficult to extract from ultrathin sections. This study has exploited high-resolution scanning electron microscopy (HRSEM) to reveal the 3-dimensional morphology of PD in the cell walls of algae, ferns and higher plants. Varied patterns of PD were observed in the walls, ranging from uniformly distributed individual PD to discrete clusters. Occasionally the thick walls of the giant alga Chara were fractured, revealing the surface morphology of PD within. External structures such as spokes, spirals and mesh were observed surrounding the PD. ...
2011-05-28
Energy Technology Data Exchange (ETDEWEB)
One bundle of Hanaro fuel irradiated up to 50%-burnup and cooled for 6 months was transported to IMEF for PIE, which has 6 elements. At first we measured the longitudinal distribution and the rotational distribution of several dominant peaks intensities from the bundle. After dismantling of the bundle we measured the longitudinal distribution of {sup 137}Cs and {sup 134}Cs peaks in each fuel element to see the burn-up feature. And finally we found out the relative number distribution of {sup 137}Cs and {sup 134}Cs for each detection point, which would be used for burn-up calculation. The relative detection efficiency of the scanning system was obtained experimentally by using the {sup 134}Cs peaks. We also checked up the azimuthal difference of peak intensity for each element, which are resulted about 2% of difference. These data will be used for the further analysis of Hanaro fuel performance evaluation. (author)
1999-09-01
Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring
International Nuclear Information System (INIS)
A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.
Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube
International Nuclear Information System (INIS)
This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...
1985-04-25
Energy Technology Data Exchange (ETDEWEB)
Scanning electrochemical microscopy (SECM) was applied to evaluate the heterogeneity of a passive film formed on a pure iron electrode in deaerated pH 8.4 borate solution. A probe current image of SECM was measured with a tip-generation/sub-strate-collection (TO/SC) mode in deaerated pH 8.4 borate solution containing 0.03 moldm{sup -3} Fe(CN){sub 6}{sup 4-} as a mediator. The difference in thickness of passive films formed on two iron plates at different potentials could be evaluated from the probe current image. The probe current image of the passivated iron surface with distinctive crystal grains was composed of the patch patterns, the shapes of which coincided completely with the shapes of the substrate crystal grains. The probe current flowed above the grain surface oriented to {l_brace}100{r_brace} plane was less than that above the grain surface oriented to {l_brace}110{r_brace} or {l_brace}111{r_brace} plane. The grain orientation dependence of probe current ...
1999-04-01
Donut-shaped high-dose configuration for proton beam radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which ...
2005-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
International Nuclear Information System (INIS)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is ...
2005-01-01
Direct patterning of gold oxide thin films by focused ion-beam irradiation
International Nuclear Information System (INIS)
For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the ...
1989-02-01
International Nuclear Information System (INIS)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the ...
1989-01-01
Detection of Second-Layer Corrosion in Aging Aircraft Fuselage
International Nuclear Information System (INIS)
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...
2006-12-01
Detection of Second-Layer Corrosion in Aging Aircraft
International Nuclear Information System (INIS)
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented ...
2009-12-01
Computer assisted axial tomography (Emi scan) in neurologic investigation
Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...
1974-01-01
Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" and one belongs to the "layer-lattice ...
2007-01-01
Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional and ...
1980-10-31
Thermodynamics of potassium diclofenac salt aqueous solutions at various temperatures
British Library Electronic Table of Contents (United Kingdom)
Solution and dilution enthalpies of aqueous solutions of potassium diclofenac salt (K_DC) were measured by an isoperibolic calorimeter at 298.15 and 318.5?K. Heat capacities of the solutions with concentrations 0.002?0.09?mol?kg?1 were obtained at the temperature interval of 288.15?318.15?K using a scanning adiabatic microcalorimeter. The virial coefficients were derived from Pitzer?s model, and the excess thermodynamic functions of both the solvent and the solute of the solution were calculated. The concentration and temperature dependencies of thermodynamic characteristics of the solution were analyzed and discussed.
2011-01-01
Study of penetration depth for V"+ with low energy implanted in peanut seeds
International Nuclear Information System (INIS)
The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95
2002-11-01
Seismic and Rockphysics Diagnostics fo Multiscale Reservoir Textures
Energy Technology Data Exchange (ETDEWEB)
We have continued to finish up our work on analyzing relationships between elastic properties and rock microstructure. We have worked on theoretical models for the effects of sorting and packing on elastic moduli and seismic velocities. After analyzing the scanning acoustic images of shales to quantify textures at different scales, we are now using theoretical inclusion models to quantify the elastic property variation with texture. In the closing phases of this project most of our efforts are now focused on writing up the results and preparing the final reports.
2005-02-01
International Nuclear Information System (INIS)
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid ...
Radiodiagnosis of Ewing's sarcoma of the rib in children
International Nuclear Information System (INIS)
The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.
Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon
International Nuclear Information System (INIS)
This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.
Pitting corrosion of nickel base alloys in halide media
International Nuclear Information System (INIS)
A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.
1988-03-06
Employment of /sup 203/Pb isotoic solution without a carrier for erythrocyte tracing
Energy Technology Data Exchange (ETDEWEB)
Possibilities of applying the Pb/sup 203/ isotonic solution without a carrier as a label of blood erythrocytes, are found. There is a number of advantages in the Pb/sup 203/ isotonic solution without a carrier, such as a high label efficiency (above 95%), a short half-life (52 hours), and a low radiation dose. These factors prove to be favourable as compared with Cr/sup 51/ widely used for these purposes. Besides, of all preparations used up to now to treat erythrocytes and to scan the spleen, it is only in the case of Pb/sup 203/ isotonic solution without a carrier that no weight amounts of chemical substances do not enter the organism.
1981-08-01
Conformal radiation therapy: technical requirements and clinical applications
International Nuclear Information System (INIS)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
1995-01-01
Bone scanning after muscle-pedicle bone graft for femoral neck fracture, (1). Preliminary report
Energy Technology Data Exchange (ETDEWEB)
sup(99m)Tc-MDP bone scintigraphy was performed on patients who received muscle-pedicle bone graft. In each of the bone head and the bone graft, a time-activity curve was obtained. In this muscle-pedicle bone graft, active revascularization and marked osteogenesis, which suggested rapid bone repairing, were observed. The bone scintigraphy was considered to be useful in observing the result of bone grafts, blood circulation, and time of bone fusion, and of value for early detection of secondary changes.
1982-04-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
