Calculations relating to two experiments that demonstrate coherent control of preformed rubidium-85 molecules in a magneto-optical trap using ultrafast laser pulses are presented. In the first experiment, it is shown that pre-associated molecules in an incoherent mixture of states can be made to oscillate coherently using a single ultrafastpulse. A novel mechanism that can transfer molecular population to more deeply bound vibrational levels is used in the second. Optimal parameters of the control pulse are presented for the application of the mechanism to molecules in a magneto-optical trap. The calculations make use of an experimental determination of the initial state of molecules photoassociated by the trapping lasers in the magneto-optical trap and use shaped pulses consistent with a standard ...
We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.
This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafastoptical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced ...
A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.
Highly dispersed silver nanoparticles embedded in mesoporous thin films (MTFs) have been synthesized by modification of the interior surface of mesoporous silica with ethylenediamine moieties, which provided the coordination sites for the Ag ions, and subsequent reduction under hydrogen atmosphere. TEM observations show the mesoporous parent films have effectively controlled the growth of the synthesized silver nanoparticles. The composite films had an ultrafast nonlinear response time, as fast as 200 fs, and a third-order nonlinear optical susceptibility of 0.94??10?10 esu, which was enhanced by the local field enhancement effect that was present when the silver nanoparticles were embedded in the surrounding dielectric matrix. The origin of the ultrafast nonlinear response and the enhanc...
We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.
Photoinduced charge separation reactions form the basis for energy storage processes in both natural and artificial photosynthesis. Moreover, rapid reversible photoinduced electron transfer reactions are a class of photophysical phenomena that can be exploited to develop schemes for optical switching. Examples from each of these fields are discussed.
Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a function of depth in tissue phantoms with a range of relevant ...
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
Recently there has been growth, in interest in non-equilibrium interaction of half-period long opticalpulses with matter. To date the opticalpulses have been produced by chopping out a half-period long segment from a longer pulse using a semiconductor switch driven by a femtosecond laser. In this paper we present new methods for producing tunable ultra-short opticalpulses as short as half an optical period using a free-electron laser driven by electron bunches with a duration a fraction of an optical period. Two different methods relying on the production of coherent spontaneous emission will be described. In the first method we show that when a train of ultra-short opticalpulses as short as one half period. We present calculations which show that the ...
A system is claimed for multiplexing or demultiplexing pulsed laser radiation having an acousto-optical device which is electrically controlled to switch a common path of high pulse rate laser radiation between a plurality of spatially distinct paths for relatively lower pulse rate laser radiation at which the pulses are sequenced according to a predetermined time pattern. The acousto-optical element typically includes a Bragg cell which is electrically driven by a set of distinct frequencies, causing deflection of radiation passing therethrough at a predetermined set of angles whereby pulsed radiation on a single path may be distributed onto the plural separate paths or radiation on plural separate paths of time-sequenced pulses of radiation can be combined into a single path of augmented pulse ...
An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.
We propose using large Air Cerenkov Telescopes (ACT's) to search for optical, pulsed signals from extra-terrestrial intelligence. Such dishes collect tens of photons from a nanosecond-scale pulse of isotropic equivalent power of tens of solar luminosities at a distance of 100 pc. The field of view for giant ACT's can be on the order of ten square degrees, and they will be able to monitor 10 to 10$^2$ stars simultaneously for nanosecond pulses of about 6th mag or brighter. Using the Earth's diameter as a baseline, orbital motion of the planet could be detected by timing the pulse arrival times.
on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...
This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.
The wavelength of the free electron laser (FEL) in Osaka University can be continuously varied in the range of 5.0-20.0 #mu#m. The FEL has a double-pulse structure, consisting of a train of macropulses of pulse duration 12 #mu#s. Each macropulse contains a train of 330 micropulses of pulse duration 5 ps. The tunability and picosecond pulses afford new medical and biological applications. However, a macropulse of long pulse duration leads to undesirable secondary effects. Precise control of the macropulse duration is essential for the high-precision applications of the FEL. An FEL pulse control system using acousto-optic modulators has been developed to investigate mechanical (shock-wave) effects of the FEL on living tissues. With this system, we have controlled photoinduced shock waves and determine the mechanism of interaction during ...
Since information has been regarded os a physical entity, the field of quantum information theory has blossomed. This brings novel applications, such as quantum computation. This field has attracted the attention of numerous researchers with backgrounds ranging from computer science, mathematics and engineering, to the physical sciences. Thus, we now have an interdisciplinary field where great efforts are being made in order to build devices that should allow for the processing of information at a quantum level, and also in the understanding of the complex structure of some physical processes at a more basic level. This thesis is devoted to the theoretical study of structures at the nanometer-scale, 'nanostructures', through physical processes that mainly involve the solid-state and quantum optics, in order to propose reliable schemes for the processing of quantum information. Initially, the main results of quantum information theory and quantum ...
An improved acousto-optic laser Q-switch uses a chirped fm pulse in the acousto-optic cell to diffract and focus the input beam into a resonating high-Q mode. When the rf acoustic pulse is not wholly within the cell, the beam is diverted to the output. A reflective surface is placed on the cell to yield only one output beam and to yield a retroflective beam back into the cavity for a high Q condition whenever a correctly generated chirp acoustic wave is in the proper postion within the cell.
We explore a planar GaAs/AlAs photonic microcavity using pump-probe spectroscopy. Free carriers are excited in the GaAs with short pump pulses. The time-resolved reflectivity is spectrally resolved short probe pulses. We show experimentally that the cavity resonance and its width depend on the dynamic refractive index of both the lambda-slab and the lambda/4 GaAs mirrors. We clearly observe a double exponential relaxation of both the the cavity resonance and its width, which is due to the different recombination timescales in the lambda-slab and the mirrors. In particular, the relaxation time due to the GaAs mirrors approaches the photon storage time of the cavity, a regime for which nonlinear effects have been predicted. The strongly non-single exponential behavior of the resonance and the width is in excellent agreement to a transfer-matrix model taking into account two recombination times. The change in width leads to a change in ...
The advances in laser technology have made available very short and intense laser pulses which can be used to seed a high-gain single-pass free-electron laser (FEL) amplifier. With these seed pulses, a regime of the FEL interaction where the radiation evolution is simultaneously dominated by nonlinear effects (saturation) and time-dependent effects (slippage) can be explored. This regime is characterized by the propagation of a solitary wavelike pulse where the power of the optical wave grows quadratically with time, its pulse length decreases and the spectral bandwidth increases. We analyze the interplay between the field and particle dynamics of this propagation regime which was studied before and termed super-radiance. Furthermore we analyze the properties of the strong higher-order harmonic emission from this wave and its behavior when propagating in a cascade FEL. The ...
Recently a new method of controlling the pulse length of a short-pulse free-electron laser (FEL) has been developed. By modulating the synchronism between the optical and electron pulses in the FEL cavity, it was found that the output power and the micropulse length of the FEL beam oscillates at the modulation frequency. In this paper, we study theoretically the behavior of the micropulse length, both in the high loss (steady state) regime and the low loss (limit cycle) regime, when a modulated desynchronism is applied. In order to do this, we analyze the dynamics of a short-pulse FEL oscillator. The modulation frequency value plays an important role in the dynamics. We find that there is a resonantlike phenomenon between the externally applied desynchronism modulation and the limit cycle oscillation without modulation of a free-electron laser.
The major activities of the various Institute's departments are highlighted. The following departments are included: (i) Tokamak; (ii) Pulse plasma systems; (iii) Thermal plasma; (iv) Materials engineering; (v) Laser plasma; and (vi) Optical diagnosis. (P.A.)
Ligand exchange of hydrated metal complexes is common in chemical and biological systems. Using the ultrafast T-jump, we examined this process, specifically the transformation of aqua cobalt (II) complexes...Full Text Available
An analytic solution is obtained for the equations of resonance coherent SRS by neglecting the population of the final level of the Raman transition for the systems with the active-medium length that is smaller than the wavelength of the incident light. For the extended systems, a numerical solution is obtained. The energy distribution of the Stokes pulses is found. The large-scale (about 100%) fluctuations of the Stokes radiation energy were observed in the case of unsaturated amplified spontaneous emission. (nonlinear optical phenomena)
A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.
In this paper, a relatively high gain (#approx =# 25 to 40 percent) free-electron laser (FEL) with an optical ring resonator is simulated using the code FELEX. The laser system corresponds to the ''burst mode'' FEL scheduled for operation at Boeing Aerospace Company in 1988. The ring consists of paraboloids, grazing incidence by hyperboloids, and a grating rhomb. The wiggler is 5 m in length and has an adjustable taper, while the electron beam is produced by an RF linac. The optical elements of the ring together with the FEL interaction in the wiggler are modeled in three spatial dimensions to investigate the system from start-up to saturation. Both single frequency and finite pulse simulations are performed. The study illustrates the necessity of mode matching the loaded resonator to maximize the extraction efficiency. The mode matching is necessary because the FEL interaction significantly alters the ...
We report an observation of a delayed all-optical routing/switching phenomenon based on ultraslow group velocity of light via nondegenerate four-wave mixing processes in a defected solid medium. Unlike previous demonstrations of enhanced four-wave mixing processes using the slow light effects, the present observation demonstrates a direct retrieval of the resonant Raman-pulse excited spin coherence into photon coherence through coherence conversion processes.
Goal was developing optical methods for study of dynamic processes at the electrode/electrolyte interface. In the past year, optical second harmonic generation was used for time-resolved measurements of thallium deposition on Cu(111). The studies of carrier dynamics in photo-excited materials have involved both steady-state and picosecond time-resolved luminescence measurements following photoexcitation of the semiconductor material.
This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a ...
Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation ...
A high power Free-Electron Laser (FEL) has lased at a wavelength of 22 #mu#m at the Japan Atomic Energy Research Institute (JAERI). The maximum power on a macro-pulse average is 1.7 kW, and it corresponds to an FEL energy of 160 #mu#J/micro-pulse. Extraction efficiency from the electron beam to the FEL radiation was measured to be 5.3% by an energy analyzer, when the maximum FEL power was coupled out. The rms wavelength spread was measured to be 4.6% at the same time. The extraction efficiency, in general, has a maximum value near the zero detuning length of an optical cavity, where (in contrast) the single-pass gain becomes smallest. A high peak current and a long macro-pulse duration are therefore indispensable for realizing high efficiency. The electron beam energy is 16.5 MeV, and the average current is 5.3 mA at a micro-pulse repetition rate of 10.4 MHz. The ...
Significant progress has been achieved recently in the growth of Yttrium Calcium Oxyborate (YCOB) crystals. Boules have been grown capable of producing large aperture nonlinear crystal plates suitable for high average power frequency conversion or optical parametric chirped pulse amplification (OPCPA). With a large aperture (5.5 cm x 8.5 cm) YCOB crystal we have demonstrated a record 227 W of 523.5nm light (22.7 J/pulse, 10 Hz, 14 ns). We have also demonstrated the applicability of YCOB for 1053 nm OPCPA.
The paper presents results of experimental research on the interaction of a pulsed plasma-ion stream with a tungsten (W) target. The pulsed hydrogen plasma was produced within the RPI-IBIS (Multi-Rod Plasma Injector) facility at IPJ in Swierk. Measurements were carried out by means of optical spectroscopy and corpuscular diagnostic techniques. For experiments with the W-target the operational conditions (so-called PID mode) were chosen when a clean hydrogen plasma stream was generated. Attention was paid to the identification of WI and WII spectral lines.
In situ optical absorption spectroscopy was used to study the generation of E' centres in amorphous SiO_2 occurring by photo-induced breaking of Si-H groups under 4.7eV pulsed laser radiation. The dependence from laser intensity of the defect generation rate is consistent with a two-photon mechanism for Si-H rupture, while the growth and the saturation of the defects are conditioned by their concurrent annealing due to reaction with mobile hydrogen arising from the same precursor. A rate equation is proposed to model the kinetics of the defects and tested on experimental data.
The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.
We have generated approximately 100 watts of frequency doubled light from the output of an electro-optically Q-switched, diode-pumped Nd:YAG slab laser oscillator operating at an average power of 200 watts (2.5 kHz repetition rate, 80 mJ/pulse, 25 ns pulsewidth). The Q-switch was a compensated z-axis propagation LiNbO{sub 3} electro-optic modulator, and the frequency conversion crystal was a thin slab of KTP. In addition, Q-switched operation at an average power of approximately 250 watts with 26 ns pulsewidths has been demonstrated.
A next generation e"+-e"- linear collider in the TeV range can be converted into a #gamma#-#gamma# collider by converting it to e"--e"- operation and then generating #gamma#-rays via Compton backscattering with optical beams. This provides unique access to some areas of fundamental physics as well as highly desirable redundancy to the collisions. The required optical beam (with a wavelength of about 1 micron) must have very high peak power, (about 1 TW) as well as average power (about 10 kW). To achieve a 1 : 1 conversion from an electron to #gamma#-quantum, each micropulse must contain about one Joule and must be about one picosecond long, the micropulse peak power being about one Terawatt. To match the electron beam pulse structure, a macropulse consists of a sequence of about one hundred micropulses separated by about one nanosecond, and the macropulses am repeated at a rate of about 100 Hz. Thus, the time average power ...
One of the main challenges for a high energy {gamma}{gamma} collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
One of the main challenges for a high energy #gamma##gamma# collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few ...
It is shown that the direct Fourier synthesization of light beams allows one to create polarity-asymmetric waves, which are able, in the process of nonlinear interaction with a medium, to break its inversion symmetry. As a result, these "polar" waves may show the effect of optical rectification in nonlinear centrosymmetric media by generating light-induced dc electric polarization. At the same time, the waves of this type, due to their unusual symmetry properties, can be used for detecting the direction and sign of a dc electric field applied to the medium. The prospects of application of polar waves to data recording and processing are discussed.
The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.
The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the ...
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
It is shown that the interpretation of the experimental results reported in the publication "Storage of Light in Atomic Vapor" by D.F.Phillips et al., Phys. Rev.Lett. 86, 783 (2001) [quant-ph/0012138] is incorrect. The experimental observation of this paper can be consistently explained in the framework of standard concepts of the physics of optical pumping and has nothing to do with "storage of light", or "dynamic reduction of the group velocity", or "light pulse compression".
Using spectral hole-burning-based ultraslow group velocity in a dilute solid medium, we report enhanced photon echo efficiency three orders of magnitude higher than that in a nonslow light regime. The enhancement is due to exponentially increased absorption of an optical data pulse owing to the enhanced photon-atom interaction in an ultraslow light regime, whereas echo reabsorption is negligibly small due to group-velocity dependent population depletion.
The history of the Czech Institute of Plasma Physics is highlighted. The article is structured as follows: Cyclic accelerators; Interaction of an external high-frequency field and high-temperature plasma - the tokamak; Interaction of an external high-frequency field and high-temperature plasma - pulse plasma systems; Low-temperature plasma - plasma technologies and new materials; Laser plasma - PALS; Optical diagnosis; and Teaching, conferences and international cooperation. (P.A.)
The properties of Mn-doped GaAs layers grown by laser deposition were investigated with measurements of Hall effect and magneto-optical Kerr effect (MOKE). The electrical and magnetic parameters of the layers were defined by growth temperature and quantity of sputtered Mn. It was shown that room-temperature ferromagnetism is revealed by MOKE and, after ruby laser 25 ns pulse annealing, by Hall effect measurements.
In this communication we propose a method to implement an all-optical astable multivibrator using the non-linear material based switches and logic gates. The scheme can operate in real time. The delay time can achieve ps(pico-second). The pulse duration can be made very low and may cross the THz easily by selecting proper material and laser source.
Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a ...
FSD-1, a designed small ultrafast folder with a ββα fold, has been actively studied in the last few years as a model system for studying protein folding mechanisms and for testing...Full Text Available
A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the ...
The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made ...
Wavy interface morphology is observed in Magnetic Pulse Welding (MPW) similarly to that of the Explosion Welding process (EXW). It is recognized that interfacial waves are formed in a periodic manner and have well defined wavelength and amplitude. The phenomenon of wave formation in EXW has been subjected to extensive investigations in which empirical and numerical models have been published. In the present study, a wave formation mechanism for MPW is presented. This wave-creation mechanism was studied by evaluating the influence of sample geometry on wave morphology using stereoscopic optical microscopy. It was found that interfacial waves are formed in a Kelvin-Helmholtz instability mechanism. Reflected shock waves interact with the welding collision point at the weld interface, where in...
A free-electron laser (FEL) user facility is discussed. The FEL, which will be operated as an oscillator, will be driven by the electron beam of the racetrack microtron (RTM) that is nearing completion. Variation of the electron kinetic energy from 17 MeV to 185 MeV will permit the FEL wavelength to be tuned from 200 nm to 10 #mu#m. Performance will be enhanced by the high brightness, low energy spread, and continuous pulse nature of the RTM electron beam. The authors are designing a new injector to increase the peak current of the RTM. A 3.6-m undulator is under construction, and the 9-m optical cavity is under design. The FEL will emit a continuous train of 3-ps pulses at 66 MHz with an average power of 10--200 W, depending on the wavelength, and a peak power of up to several hundred kW. An experimental area is being prepared with up to five stations for research using the FEL beam.
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.
We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)
In this article, we present our consistent efforts to explore the dynamical pathways of the migration of electronic radiation by using ultrafast (picosecond/femtosecond time scales) F?rster resonance energy transfer (FRET) technique. The ultrafast non-radiative energy migration from an intrinsic donor fluorophore (Tryptophan, Trp214) present in domain IIA of a transporter protein human serum albumin (HSA) to various non-covalently/covalently attached organic/inorganic chromophores including photoporphyrin IX (PPIX), polyoxovanadate [V15As6O42(H2O)]-6 clusters (denoted as V15) and CdS quantum dots (QDs) has been explored. We have also used other covalently/non-covalently attached extrinsic fluorogenic donors (NPA, ANS) in order to exploit the dynamics of resonance energy migration of an enz...
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to ...
Pulsed radiolysis method is used to study transformations intermediates of 6-aminophenalenone in ethanol. In alkaline medium the main product is radical-anion of 6-aminophenalenone, which optical absorption spectrum contains two bands with maxima at 355 and 400 nm. The particle precursors are e_s, CH_3CHOH and CH_3CHO"- radicals. In neutral and acid medium radical-anions are protonated in reactions with alcohol and hydrogen ions. The resulting H-adduct of 6-aminophenalenone has optical absorption maxima at 350 and 390 nm. Availability of two maxima is related to two various product structures. Molar extinction coefficients of radical-anions and H-adducts of 6-aminophenalenone and rate constants of reactions with their participation are estimated.
Intermediate products of the conversions of 6-aminophenalenone in ethanol were investigated by pulse radiolysis. In alkaline medium the main product is the 6-aminophenalenone radical cation, the optical absorption spectrum of which contains two bands with maxima at 355 and 400 nm. The precursors of this particle are e_s, CH_3CHOH and CH_3CHO"- radicals. In neutral and acid medium, radical cations are protonated in reactions with alcohol and hydrogen ions. The H-adduct of 6-aminophenalenone that arises has optical absorption maxima at 350 and 390 nm. The presence of two maxima is due to two different structures of the product. The molar extinction coefficients of the radical anions and H-adducts of 6-aminophenalenone and the rate constants of the reactions involving them were estimated. 6 refs., 4 figs., 2 tabs.
Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
The spectral dependences of absorption photoinduced in a pure bismuth titanium oxide crystal by 532-nm laser pulses are studied. It is shown that optical absorption in the crystal in the range from 492 to 840 nm increases with increasing exposure. The photoinduced absorption relaxes in the dark for more than 60 hours. A model of photoinduced absorption is proposed which assumes the population of two trap centres with the normal energy distribution law for the concentrations of electrons photoexcited from donors to the conduction band. This model well describes the spectral dependences of photoinduced absorption by using the average ionisation energies of the traps E{sub 1} = 1.60 eV and E{sub 2} = 2.57 eV. The model is used to estimate the increase in the photorefractive sensitivity of a bismuth titanium oxide crystal in the near IR region, which was earlier observed after exposing the crystal to visible radiation. It is predicted that the ...
A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also ...
A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser ...
A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met ...
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
By gas-source molecular-beam epitaxy, we obtained a device-quality GaInP epitaxial layer lattice matched to (100)-GaAs substrates, with a photoluminescence efficiency comparable to that of a crystal grown by liquid-phase epitaxy. A GaInP/AlInP double heterostructure laser with a GaInP active layer was fabricated, and pulsed lasing operation was achieved at room temperature for, we believe, the first time.
Various particle-photon or beam-wave interactions are discussed. To be of use as intense radiation sources, it is necessary that these interactions produce coherent radiation. The free electron laser (FEL), developed on the basis of undulator radiation, is the result of many years of interaction between physics and technology. It has many features, such as continuous tunability over a wide wavelength range, excellent optical quality, high power and short pulse capability, and thus has many potential applications. FEL development in China and abroad are mentioned and the Beijing FEL presented to illustrate the physics and technology involved in an FEL project.
The mechanistic aspects of electrochemical reductions of U"V"IO_2(acac)_2dmso(acac=acetylacetonate, dmso=dimethyl sulfoxide) complex with bidentate ligand(acac) in DMSO were investigated by using cyclic voltammetry, normal pulse voltammetry, and spectrophotometer equipped with an optical transparent thin layer electrode cell. It is concluded that the uranyl complexes with bidentate ligands at the equatorial plane form stable U(V) complexes by the electrochemical reduction and that their molar extinction coefficients in the visible region are very small. (J.P.N.).
We demonstrate rapid fabrication of submicrometer-diameter pores in borosilicate glass using femtosecond laser machining and subsequent wet-etch techniques. This approach allows direct and repeatable...Full Text Available
The motivation, feasibility and potential for two unconventional collider concepts - the Gamma-Gamma Collider and the Muon Collider - are described. The importance of the development of associated technologies such as high average power, high repetition rate lasers and ultrafast phase-space techniques are outlined.
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize the output energy. ...
... In 1982 an acousto-optic spectrum analyzer incorporated ... the OPTIMP is the optically controlled optical ... switch that changes the intensity reflectance ...
For InAs-GaAs based quantum dot lasers emitting at 1300 nm, digital modulation showing an open eye pattern up to 12 Gb s{sup -1} at room temperature is demonstrated, at 10 Gb s{sup -1} the bit error rate is below 10{sup -12} at -2 dB m receiver power. Cut-off frequencies up to 20 GHz are realised for lasers emitting at 1.1 {mu}m. Passively mode-locked QD lasers generate opticalpulses with repetition frequencies between 5 and 50 GHz, with a minimum Fourier limited pulse length of 3 ps. The uncorrelated jitter is below 1 ps. We use here deeply etched narrow ridge waveguide structures which show excellent performance similar to shallow mesa structures, but a circular far field at a ridge width of 1 {mu}m, improving coupling efficiency into fibres. No beam filamentation of the fundamental mode, low a-factors and strongly reduced sensitivity to optical feedback are observed. QD lasers are thus superior to ...
Monodisperse noble metal nanoparticles are of tremendous interest for numerous applications, such as surface-enhanced Raman spectroscopy, catalysis or biosensing. However, preparation of monodisperse metal nanoparticles is still a challenging task, because typical preparation methods yield nanoparticle ensembles with broad shape and/or size distributions. To overcome this drawback, tailoring of metal nanoparticles with laser light has been developed, which is based on the pronounced shape- and size-dependent optical properties of metal nanoparticles. I will demonstrate that nanoparticle tailoring with ns-pulsed laser light is a suitable method to prepare nanoparticle ensembles with a narrow shape and/or size distribution. While irradiation with ns-pulsed laser light during nanoparticle growth permits a precise shape tailoring, post-grown irradiation allows a size tailoring. For example, the initial broad Gaussian size ...
We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.
The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)
An experimental study and a theoretical simulation were made of stimulated Raman scattering (SRS) conversion into shifted components. It was found that there were optimal values of the pressure and focal distance for conversion into the first 'blue' satellite of the first Stokes component. A study was made of the spatial and temporal dynamics of SRS conversion, which took into account generation of the shifted components. It was demonstrated theoretically and experimentally that the satellite intensity could be enhanced significantly by additional electron-collision excitation of the vibrational levels in the conversion medium or by the application of pairs of pump pulses. The maximum efficiency of conversion to the first 'blue' satellite of the first Stokes component was 10% and the satellite intensity reached one-third of the intensity of the main Stokes line. (nonlinear optical phenomena and devices)
A method for range-resolved gas sensing using path-integrated optical systems is presented. The method involves dividing an absorption path into several measurement segments and extracting the gas concentration in each segment from two path-integrated measurements. We implemented the method with tunable lasers (a 1389-nm VCSEL and a 10.9-?m pulsed quantum cascade laser) and a group of retro reflectors (RRs) distributed along absorption paths. Using a rotating mirror with the VCSEL configuration, we could scan a group of seven tape RRs spaced by 10?cm in ??9?ms to extract an H2O concentration profile. Reduced H2O concentrations were recorded in the segments purged with dry air. Hollow corner cube RRs were used in the quantum cascade laser configuration at distances up to 1.1?km from the las...
The high repetition rate and low single-pass gain inherent in an rf-driven Free Electron Laser (FEL) dictate that the laser system be configured as an oscillator. This allows the laser's electric field to build up over many passes around a high Q cavity. By way of contrast, the high-current capability of the Induction Linac (IL) system permits high single-pass optical gain, but the relatively low duty factor precludes oscillator operation; the pulses are neither long enough nor often enough to permit a field to accumulate in a cavity. The IL is thus configured as a MOPA (master oscillator/power amplifier) with a conventional laser serving as the MO. This report concentrates on the status of IL-driven FEL research at LLNL and gives a description of several applications for the high-peak-power radiation produced by an induction linac FEL.
Indium sulfide thin films were deposited onto indium-tin-oxide coated glass substrate by electrochemical deposition from an aqueous solution containing In2 (SO4) 3 and Na2S2O3. The deposition conditions were optimized on the basis of data obtained by scanning electron microscope, Auger electron spectroscopy and optical transmission measurements. Furthermore, the photosensitivity of the films was observed by means of photoelectrochemical measurements, which confirmed that the indium sulfide showed n-type conduction. The X-ray diffraction and Raman studies revealed that the as-grown films were amorphous or nanocrystalline in nature and became polycrystalline In2S3 after annealing.
Pulsed DC-plasma nitriding has been applied to form nitride layer having only a diffusion layer. The discharge current with the variation of discharge gases is proportional to the intensity of N{sub 2}{sup +} peak in optical emission spectroscopy during the plasma nitriding. The discharge current, microhardness in surface of substrate and depth of nitride layer increased with the ratio of N{sub 2} to H{sub 2} gas in discharge gases. When the ratio of N{sub 2} to H{sub 2} is lower than 60% in the discharge gases, high microhardness value of 1100Hv nitride layer which contains no compound layer has been formed. (author). 20 refs., 6 figs., 1 tab.
We report the results of characterization of nonlinear refractive index of the composite material produced by MeV Ag ion implantation of LiNbO{sub 3} crystal (z-cut). The material after implantation exhibited a linear optical absorption spectrum with the surface plasmon peak near 430 nm attributed to the colloidal silver nanoclusters. Heat treatment of the material at 500 C caused a shift of the absorption peak to 550 nm. The nonlinear refractive index of the sample after heat treatment was measured in the region of the absorption peak with the Z-scan technique using a tunable picosecond laser source (4.5 ps pulse width). The experimental data were compared against the reference sample made of MeV Cu implanted silica with the absorption peak in the same region. The nonlinear index of the Ag implanted LiNbO{sub 3} sample produced at five times less fluence is on average two times greater than that of the reference. (orig.) 20 refs.
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design ...
The ultrafast dynamics of the DNA fluorescent dye Sybr Green I (SG) has been studied in buffer, single-stranded (ssDNA), double-stranded (dsDNA) and triple-stranded DNA (tsDNA). The fluorescence quantum yield of SG increases dramatically when bound to DNA (including tsDNA). The fluorescence dynamics of the free SG has shown two decay components with 0.15-0.4ps and 1.3-2.1ps time constants, depending on the fluorescence wavelength. Upon binding to DNA, the dynamics becomes slower exhibiting four decay components. This is mainly due to the restriction of the internal motions of the dye caused by the relatively rigid environment of the dye complexed with DNA.
A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including the control grids is supported by two high voltage ceramic bushings in a stainless steel vacuum chamber. For acceleration of ...
This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD ...
High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin rotator and describe two types of transmission-based neutron ...
... the application of an acousto- optical tunable filter ... Couplers for Large Switch-Array Applications ... Symmetric Integrated Optic X Junction," Electronics ...
Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power extractor with a circular DL waveguide and tested it with single electron bunches and bunch trains. The output RF frequency (7.8GHz) is the sixth harmonic of the operational ...
Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...
The molar extinction coefficients at the absorption maximum of the solvated electron spectrum have been evaluated to be 900, 970, and 1000 mol-1?m2 for 1,2-ethanediol (12ED), 1,2-propanediol (12PD), and 1,3-propanediol (13PD), respectively. These values are two-third or three-fourth of the value usually reported in the published report. Picosecond pulse radiolysis studies have aided in depicting the radiolytic yield of the solvated electron in these solvents as a function of time from picosecond to microsecond. The radiolytic yield in these viscous solvents is found to be strongly different from that of the water solution. The temperature dependent absorption spectra of the solvated electron in 12ED, 12PD, and 13PD have been also investigated. In all the three solvents, the optical spectra shift to the red with increasing temperature. While the shape of the spectra does not change in 13PD, a widening on the blue side of the absorption band is ...
One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight instrument uses electron impact ionization ...
Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers adjacent tothe ...
Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie arrangement.
The aim of this work is to describe the processes during plasma nitriding of Nb-containing, powder metallurgy prepared (PM) tool steel. PM steel was studied containing 2.5% C, 3.3% Si, 6.2% Cr, 2.2% Mo, 2.6% V, 2.6% Nb and 1.0% W, produced by melt atomization and hot isostatic pressing. The hardened and tempered steel was plasma nitrided at temperatures ranging from 470 to 530 deg. C. The nitriding time was 30-180 min. Optical microscopy, electron microscopy, XRD, EDS, WDS and hardness measurements were used to study the steel's properties, microstructure, phases and chemical composition. The nitriding temperature of 470 deg. C was found to be unsuitable for practical use because the layers prepared at this temperature were non-uniform. The compound layer formed by M{sub 2,3}(C,N) and M{sub 4}N was found after nitriding at temperatures of 500 and 530 deg. C for at least 60 min. The effect of niobium on the formation of this layer was studied.
The aim of this work is to describe the processes during plasma nitriding of Nb-containing, powder metallurgy prepared (PM) tool steel. PM steel was studied containing 2.5% C, 3.3% Si, 6.2% Cr, 2.2% Mo, 2.6% V, 2.6% Nb and 1.0% W, produced by melt atomization and hot isostatic pressing. The hardened and tempered steel was plasma nitrided at temperatures ranging from 470 to 530 deg. C. The nitriding time was 30-180 min. Optical microscopy, electron microscopy, XRD, EDS, WDS and hardness measurements were used to study the steel's properties, microstructure, phases and chemical composition. The nitriding temperature of 470 deg. C was found to be unsuitable for practical use because the layers prepared at this temperature were non-uniform. The compound layer formed by M_2_,_3(C,N) and M_4N was found after nitriding at temperatures of 500 and 530 deg. C for at least 60 min. The effect of niobium on the formation of this layer was studied.
Distributed Bragg reflectors (DBRs) composed of In_0_._5Al_0_._5P/In_0_._5(Al_yGa_1_-_y)_0_._5P quarter-wave layers have been prepared using metalorganic vapor phase epitaxy. The structures were grown over a wide range of high-index layer composition (0#<=#y#<=#0.6) and peak reflectivity wavelength (720 nm#<=##lambda##<=#565 nm, covering the spectrum from deep red to green). In all cases observed and calculated reflectance spectra were in excellent agreement. Using these DBRs, an undoped all-phosphide visible vertical cavity surface-emitting laser structure was grown. Under pulsedoptical excitation at room temperature, lasing was obtained at a wavelength of #lambda##approx#670 nm, with a threshold power density comparable to that observed from similar structures prepared using AlAs/AlGaAs DBRs.
The lasing of the first free-electron laser (FEL) in the world was successfully carried out in 1977, so the history of FELs as a light source is not so long. But FELs are now utilized for research in many scientific and engineering fields owing to such characteristics as tunability of the wavelength, and short pulse and high peak power, which is difficult utilizing a common light source. Research for industrial applications has also been carried out in some fields, such as life sciences, semiconductors, nano-scale measurement, and others. The task for the industrial use of FEL is the realization of high energy efficiency and high optical power. As a means of promoting realization, the combining of an FEL and superconducting linac is now under development in order to overcome the thermal limitations of normal-conducting linacs. Further, since tuning the wavelength is carried out by changing the magnetic density of the undulator, which is now ...
The coherent interaction of femtosecond laser pulses and a thin CdSe sample is investigated both experimentally and theoretically. Observation of coherent phenomena in semiconductors is very rare because the incoherent processes occur in the femtosecond time domain in these materials. One example of such a phenomena is the so called optical Stark effect of exciton where a blue shift of the exciton resonance occurs as a result of pumping below the bandgap. The coherent effects involving band-to-band and also exciton transitions. Using femtosecond transmission measurements clear evidence was observed for coherent interference effects of the light field and the driven material polarization. These interferences manifest themselves as oscillatory structures in the differential transmission spectra. The oscillatory features are explained by comparison with a semiclassical theory. Examples of the computed results are presented for different time ...
We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)
The dynamical decoupling (DD) aims at suppressing the decoherence by means of coherent control pulses. Even if devices exist where instantaneous pulses are an adequate approximation, experimentally a finite duration #tau#_p and a bounded amplitude are inevitable. They are the cause of additional errors which can be corrected by designing the pulse shape appropriately. The new pulse has the overall effect of an ideal, instantaneous pulse with the advantage of decoupling the spin (or qubit) from the bath up to the order O(#tau#_p"3). The limitation of the no-go theorem for #pi# pulses is avoided. Hence, the Uhrig sequence (UDD), originally thought for ideal #pi# pulses, works also for bounded control Hamiltonians. Numerical simulations show that concatenated sequences of real pulses are effective against general ...
Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results reveal that the carrier dynamics is strongly affected by N ...
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an ...
we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed.
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed. (author).
A univibrator and a pulse height discriminator using tunnel diodes and backward diodes are described, along with their applications in pulse shaping and fast coincidence technique. The main advantages achieved are simplicity of design and speed. The characteristics of the two diodes are shown. (auth)
X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and ...
... The acousto-optic device have a 30 MHz 1 ... coherent systems including compact non-coherent optical ... a relatively simple phase switching approach. ...
Background and ObjectivePulsed dye laser (PDL) treatment of cutaneous vascular lesions is associated with variable and unpredictable efficacy. Thus, alternative treatment...Full Text Available
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
... Biomedical Engineering Optical and Photonic Materials and Devices Fundamental Optical Interactions ... of Texas Medical School OPTICAL AND PHOTONIC MATERIALS AND DEVICES Gary Bjorklund, IBM, Chair Nan ...
BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
An integrated mirrorless bistable optical device based on the Mach-Zehnder interferometric optical switch has been proposed and demonstrated experimentally using a Ti:LiNbO3 waveguide. The resulting device is capable of combining more than two of them to realize multifunctional optical devices such as optical multivibrators.
A device for marking and searching for information on a magnetic carrier is described. In order to increase the noise immunity and reliability of the data recording and reading paths, the recording head is included between the amplifier of the clock pulses for the master oscillator and through the amplifier of the code pulses for the logical element unit. The reproduction head is connected through the code pulse shaper-amplifier with a switch which is connected with the display unit, and through another analogous clock pulse amplifier with a multivibrator.
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
Pulse radiolysis has been used to optically and kinetically characterize the transient free radicals formed by the reaction of H"s"m"-"b"u"l"l"e"t, N_3"s"m"-"b"u"l"l"e"t, or OH"s"m"-"b"u"l"l"e"t with 2,4,5-trichlorophenol (TCP-OH). The hydroxy-2,4,5-trichlorocyclohexadienyl radical (H-TCP-OH) formed by H"s"m"-"b"u"l"l"e"t addition to TCP-OH [k = (1.1 #+-# 0.2) x 10"9 M"-"1 s"-"1] has an absorption maximum at 360 nm with #epsilon#_3_6_0 = (4700 #+-# 1000) M"-"1 cm"-"1. The 2,4,5-trichlorophenoxyl radical (TCP-O"s"m"-"b"u"l"l"e"t) formed by the reaction of N_3"s"m"-"b"u"l"l"e"t with TCP-O- [k = (4.3 #+-# 0.8) x 10"9 M"-"1 s"-"1] has an absorption maximum at 430 nm with #epsilon#_4_3_0 = (3600 #+-# 600) M"-"1 cm"-"1. The dihydroxy-2,4,5-trichlorocyclohexadienyl radical (HO-TCP-OH) formed by OH"s"m"-"b"u"l"l"e"t radical addition to TCP-OH [k = (1.2 #+-# 0.1) x 10"1"0 M"-"1 s"-"1] has an absorption maximum at 320 nm with #epsilon#_3_2_0 = (5300 #+-# ...
The ion nitriding treatment is a process widely used in steel alloys to improve the material's properties; such as surface hardness, resistance to wear, fatigue life and resistance to corrosion. But geometric changes in the components can produce during the nitriding process different effects on the behavior of the plasma, such as local variations in the electric field, an empty cathode effect, etc. These in turn can affect among other factors the local temperature and therefore the kinetics of the process, generating variations in the compound layer thicknesses and zone of diffusion, and micro-hardness profile. These heterogeneities limit the effectiveness of the plasma nitriding process, where control and duplication of the surface modification are most important. This work aims to study the effect of the geometry of the pieces treated with ionic nitriding, especially the effect of the orifices. An understanding of the operating mechanisms is sought in order to predict the ...
The aim of this study was to investigate whether sub-ablative pulsed C0{sub 2} laser (1 0,6 {mu}m) irradiation is capable of reducing the susceptibility of the dental enamel to demineralization, and thus achieving a potential caries-protective effect. The crowns of 51 bovine front teeth, embedded in acrylic resin and polished until exposure of flat enamel surface, were used. The samples were cut in cubes of 10x10 mm, and totally coated with acid-resistant nail varnish, except for an enamel exposed window of 16 mm square. Three groups (n=17) were obtained: control group (CG) not irradiated; group laser A (LA) and group laser B (LB) where the samples were irradiated. The conditions were 60 mJ, 100 Hz, 0,3 J/cm{sup 2} for LA and 135 mJ, 10 Hz, 0,7 J/cm{sup 2} for LB. Two samples of each group were submitted to SEM analysis and fifteen to demineralization in 3 ml acetate buffer solution (0,1 mol/L) with pH 4,5 for 24h at 37 deg C, with regular agitation. After the ...
Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.
Recently it was demonstrated that long-lived quantum coherence exists during excitation energy transport in photosynthesis. It is a valid question up to which length, time and mass scales quantum coherence may extend, how one may detect this coherence and what, if any, role it plays in the dynamics of the system. Here we suggest that the selectivity filter of ion channels may exhibit quantum coherence, which might be relevant for the process of ion selectivity and conduction. We show that quantum resonances could provide an alternative approach to ultrafast two-dimensional (2D) spectroscopy to probe these quantum coherences. We demonstrate that the emergence of resonances in the conduction of ion channels that are modulated periodically by time-dependent external electric fields can serve as signatures of quantum coherence in such a system. Assessments of experimental feasibility and specific paths towards the experimental realization of such experiments are ...
The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...
Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically selective excitation of uranium vapor also ...
The barrier glow discharge between two planar electrodes, covered with dielectric, is studied under high-voltage pulsed power supply. Wide applications of such type of discharges, in particular, for ozone production, stimulated a number of investigations in this direction. In this work we investigated the dependence of ozone concentration on the duration and the rate of pulse rise of the applied voltage. The thyristor converter circuit with the shortening of input pulses on the base of the saturable throttle was used for the realization of this task. The output pulses with amplitude up to 15 kV, repetition frequency of 1 kHz, pulse duration of 0.3 #mu#s (or 7 #mu#s) and the rate of pulse rise of 0.1 #mu#s were generated with this scheme. Measurements of the ozone concentration produced in the air mixture have shown that its value increased by factor two with ...
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks ...
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can ...
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
In a seeded high-gain free-electron laser (FEL), where a coherent laser pulse interacts with an ultrarelativistic electron beam, the seed laser pulse can be frequency chirped, and the electron beam can be energy chirped. Besides these two chirps, the FEL interaction introduces an intrinsic frequency chirp in the FEL even if the above-mentioned two chirps are absent. We examine the interplay of these three chirps. The problem is formulated as an initial value problem and solved via a Green function approach. Besides the chirp evolution, we also give analytical expressions for the pulse duration and bandwidth of the FEL, which remains fully longitudinally coherent in the high-gain exponential growth regime. Because the chirps are normally introduced for a final compression of the FEL pulse, some conceptual issues are discussed. We show that to get a short pulse duration, an energy ...
In the process of backward Raman amplification (BRA), the leading layers of the seed laser pulse can shadow the rear layers, thus weakening the effective seeding power and affecting parameters of output pulses in BRA. We study this effect numerically and also analytically by approximating the pumped pulse by the ''*-pulse'' manifold of self-similar solutions. We determine how the pumped pulse projection moves within the *-pulse manifold, and describe quantitatively the effective seeding power evolution. Our results extend the quantitative theory of BRA to regimes where the effective seeding power varies substantially during the amplification. These results might be of broader interest, since the basic equations, are general equations for resonant 3-wave interactions.
The effect of asymmetric laser pulses on electron yield from a laser wakefield accelerator has been experimentally studied using > 10{sup 19} cm{sup -3} plasmas and a 10 TW, > 45 fs, Ti:Al{sub 2}O{sub 3} laser. Laser pulse shape was controlled through non-linear chirp with a grating pair compressor. Pulses (76 fs FWHM) with a steep rise and positive chirp were found to significantly enhance the electron yield compared to pulses with a gentle rise and negative chirp. Theory and simulation show that fast rising pulses can generate larger amplitude wakes that seed the growth of the self-modulation instability and that frequency chirp is of minimal importance for the experimental parameters.
An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.
Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.
Free-electron laser (FEL) experiments have been conducted with the 38-MeV L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. It is a 1.3 GHz RF linac with a thermoionic gun, and equipped with two 12th and one 6th sub-harmonic prebunchers for producing the high-intensity single-bunch beam with a charge up to 67 nC/bunch. For oscillation experiments of FEL, the gun is replaced with that with a smaller cathode area in order to reduce the emittance of the beam. The normalized emittance has been measured to be 200 {pi} mm-mrad. The linac is operated in the long-pulse mode and one of the 12th sub-harmonic bunchers and the 6th sub-harmonic buncher are operated, so that the time duration of the macropulse is 4 {mu}s and the spacing between micropulses is 9.2 ns. The length of the micropulse is 30-40 ps and the charge in each micropulse is 2 nC. The electron beam from the linac is transported to a wiggler which has the period ...
Flux-grown ScPO{sub 4} single crystals exhibit a number of luminescence bands in their x-ray-excited luminescence spectra - including sharp lines arising from rare-earth elements plus a number of broad bands at 5.6 cV, 4.4 eV, and 3 eV. The band at 5.6 eV was attributed to a self-trapped exciton (STE) [l], and it could be excited at 7 eV and higher energies. This luminescence is strongly polarized (P = 70 %) along the optical axes of the crystal and exhibits a kinetic decay time constant that varies from several ns at room temperature to {approximately}10 {micro}s at 60 K and up to {approximately}1 ms at 10 K. It is assumed that the STE is localized on the SC ions. The band at 3 eV can be excited in the range of the ScPO{sub 4} crystal transparency (decay time = 3 to 4 {micro}s.) This band is attributed to a lead impurity that creates different luminescence centers. At high temperatures, the band at 4.4 eV is dominant in the x-ray-excited TSL and afterglow spectra. ...
K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsedoptical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and compared to various theoretical models. ...
'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. Experiments with gypsum and ...
We have estimated the mixing height (MH) and investigated the relationship between vertical mixing and ground-level ozone concentrations in Seoul, Korea, by using three ground-based active remote sensing instruments operating side by side: micro-pulse lidar (MPL), differential absorption lidar (DIAL), and differential optical absorption spectroscopy (DOAS). The M H is estimated from MPL measurements of aerosol extinction profiles by the gradient method under convective conditions. Comparisons of the MHs estimated from MPL and radiosonde measurements show a good agreement (r"2 = 0.99). Continuous MPL measurements with high temporal and vertical resolution reveal the diurnal variations of the MH under convective conditions and the presence of a residual layer during the nighttime. Comprehensive measurements of ozone and aerosol by MPL, DIAL and DOAS during an high ozone episode (24-26 May 2000) in Seoul, Korea, reveal that (1) photochemical ozone ...
Spin-polarized liquid helium-3 is prepared by laser optical pumping in low magnetic field and at room temperature, prior to fast liquefaction of the polarized sample. The use of a new helium-3 cryostat enabled us to obtain liquid helium-3 with polarization rates up to 25 % at well-stabilized temperatures (around 0.5 K). We could thereby study the effect of nuclear polarization on liquid-vapour equilibrium, and particularly on the saturated vapour pressure. Very sensitive capacitive gauges were developed. We estimated (to first order in M{sup 2}) the expected effects when the polarization M is suddenly destroyed. These effects were experimentally observed in helium-3/helium-4 mixtures, in pure helium-3, only a transient increase in pressure has been recorded. We then describe in a third part a preliminary experiment which aimed at determining the longitudinal relaxation time T1 in mixtures. Relaxation on the walls is efficiently reduced by a cesium coating and T1s ...
Cretaceous Sunniland Formation rudistid reservoir facies buried at 3,520 meters (92 C) between evaporite units contain marginally mature algal sapropelic carbonate source rock hydrocarbons. The closed system aids in identification of porosity redistribution related to hydrocarbon emplacement. Multiple dissolution and cementation events associated with hydrocarbon migration pulses are particularly evident along stylolites. Corrosion usually predates typically interparticle first generation saddle dolomite, and corroded saddle dolomite may be observed with two generations of optically continuous limpid overgrowths separated by a corrosive boundary. Dissolution or dedolomitization may provide a magnesium source for subsequent dolomite cements. Carbonic and organic acids are probable primary corrosive agents. Moldic, stylolite and fracture porosity, often reduced by dolomite cements, was generated. Moldic pores may develop from peloids by ...
Research highlights: {yields} The use of resonant photoemission in its 'core-hole clock' expression for the study of the dynamical charge transfer across hybrid organic-inorganic interfaces and for the intermolecular charge transfer in the bulk of organic thin films is reviewed. {yields} The electronic coupling to the substrate and the efficiency of charge transport across hybrid interfaces is different for individual electronic subsystems of the molecular adsorbate. {yields} The intermolecular charge transfer in the bulk of discotic liquid crystals occurs on the order of a few femtoseconds and is faster than expected from the macroscopic charge transport characteristics of the material. -- Abstract: The focus of this brief review is the use of resonant photoemission in its 'core-hole clock' expression for the study of two important problems relevant for the field of organic electronics: the dynamical charge transfer across hybrid organic-inorganic ...
This thesis details the first direct ultrafast measurements of the dynamic thermal expansion of a surface and the temperature dependent surface thermal diffusivity using a two-color reflection transient grating technique. Studies were performed on p-type, n-type, and undoped GaAs(100) samples over a wide range of temperatures. By utilizing a 90 fs ultraviolet probe with visible excitation beams, the effects of interband saturation and carrier dynamics become negligible; thus lattice expansion due to heating and subsequent contraction caused by cooling provided the dominant influence on the probe. At room temperature a rise due to thermal expansion was observed, corresponding to a maximum net displacement of {approximately} 1 {Angstrom} at 32 ps. The diffracted signal was composed of two components, thermal expansion of the surface and heat flow away from the surface, thus allowing a determination of the rate of expansion as well as the surface thermal diffusivity, ...
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
The continuing rapid increase in available computing power has not reduced the importance of efficient methods of optical system assessment for automatic lens design. On the contrary, the new capabilities simply show that truly automatic optical design wi...
An optical flow gradient algorithm was applied to spontaneously forming networks of neurons and glia in culture imaged by fluorescence optical microscopy in order to map functional calcium signaling...Full Text Available
Upon illumination of an optically driven Q-switch 35 over conventional electro- optic, acousto-optic and medium located inside the laser cavity with an ...
PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available
During formation of the optic projection in astray/robo2 mutant zebrafish, optic axons exhibit rostro-caudal pathfinding errors, ectopic midline crossing and...Full Text Available
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating ...
Background and ObjectivesDisruption of the vocal fold extracellular matrix (ECM) can induce a profound and refractory dysphonia. Pulsed dye laser (PDL) irradiation...Full Text Available
We have studied both theoretically and experimentally a new scheme of active pulse compression in a free electron laser (FEL) amplifier. The pulse compression scheme presented here is the following. A frequency-chirped pulse is injected into the FEL interaction region. Because of the high gain and narrow bandwidth of the FEL interaction, only the resonant frequency band of the pulse is actively amplified, resulting in a short pulse of high power coherent radiation at the output of the laser. For our experimental parameters (beam voltage #approx =# 150 kV, current #approx =# 5.0 A, wiggler period #approx =# 3.5 cm and gain #approx =# 10 dB), pulses of a few nanoseconds were generated at #approx =# 10 GHz after an interaction length of 2.30 m, in good agreement with theoretical expectations. For the same input pulses (width > 100 ns, ...
The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.
We report coupling and guiding of pulses of peak power up to 0.3 TW in 1.5 cm long preformed plasma waveguides generated in a high repetition rate argon gas jet. Coupling of up to 52% was measured for 50 mJ, -110 fs pulses injected at times longer than 20 ns, giving guided intensities up to -5x1016 W/cm2. It was found that for short delays between waveguide generation and pulse injection, pulse shortening occurred, with this effect reduced as delay was increased. Injection into the waveguide of two consecutive pulses separated by a few nanoseconds resulted in the reduction of shortening of the second pulse at all delays. Femtosecond time-resolved shadowgrams of the coupling of injected pulses into the waveguide show that there is ?0.5 mm of neutral gas remaining at the waveguide entrance after waveguide generation.
This progress report presents a detailed description of the background, technology and application, and Statement of Work for the development of a coal-fired pulse combustor for residential space heating.
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
A line-to-plate reactor was set-up in the experimental study on the application of nanosecond pulsed corona discharge plasma technology in environmental pollution control. Investigation on the attenuation and distortion of the amplitude of the pulse wave front and the discharge image as well as the waveform along the corona wire was conducted. The results show that the wave front decreases sharply during the corona discharge along the corona wire. The higher the amplitude of the applied pulse is, the more the amplitude of the wave front decreased. The wave attenuation responds in a lower corona discharge inversely. To get a higher efficiency of the line-to-plate reactor a sharp attenuation of the corona has to be considered in practical design.
We report on the collision of 1.5 ps (FWHM) laser pulses traversing at 17 a short similar 7 ps (FWHM) 46.6 GeV electron bunch. The phase-locked system used to maintain the correct timing of the laser pulses and the appropriate diagnostics are described. The jitter between the laser and electron pulses is determined from the stability of the observed rate of Compton scatters and can be described by a Gaussian distribution with #sigma#_j#approx =#2.2 ps. (orig.).
Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions
In this paper, model analysis into the time-dependent transmembrane potential at the outer cell membrane is presented, for applied high-intensity electric pulses having durations in the nanosecond range or smaller. It is argued that the frequency-dependent dielectric response of cell membranes could be used to advantage for stronger bioeffects by employing shorter pulses. Our model calculations predict faster transmembrane voltages and larger electroporation densities for a given external energy with pulse durations in the subnanosecond regime. This temporal regime would be used, for example, in the electrotherapy of mixed cell ensembles having different dielectric response properties. PMID:21937300
in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...
... electronic feedback system' connected to a Q switch ... The use of acousto-optic (AO) beam steering devices for BMDO (SDI) applications is very ...
An analysis is made of the basic principles and methods of construction of integrated optical circuits (IOC) for data processing, which are optical waveguide processors in the integrated form. A classification is provided of IOC in accordance with the nature of the input connections to optical components and in accordance with their intended function. An analysis is made of the current status of research and development of analog IOC for handling analog and digital signals, IOC for computing technology, and switching IOC. A detailed analysis is made of IOC with different functions in data processing: spectrum analyzers and correlators, analog-digital converters, circuits for identification of data sets and for encoding of signals, threshold and multistable circuits, logic and arithmetic units, and switching arrays. Descriptions are given of IOC for optically controlled data handling: bistable purely ...
There is a requirement for a noninvasive technique to monitor stem cell differentiation. Several candidates based on optical spectroscopy are discussed in this review: Fourier transform infrared (FTIR)...Full Text Available
... switching off all the pixels causes all the spectrum lines to disappear (top of Figure 6), next, that switching off one ... Acousto-optic spectrum analyser ...
Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available
The optical and nonlinear optical properties of colloidal solutions of silver obtained by laser ablation in water and ethanol are studied. It is shown that freshly prepared colloids experience a full or partial sedimentation by changing their nonlinear optical properties. Aqueous colloids undergo a partial sedimentation and their nonlinear optical absorption changes to nonlinear optical transmission. The obtained results are interpreted using the Drude model for metal particles taking the particle size into account and can be explained by the sedimentation of larger silver particles accompanied by the formation of a stable colloid containing silver nanoparticles with a tentatively silver oxide shell. The characteristic size of particles forming such a stable colloid is determined and its optical nonlinearity is estimated.
... A technique of the prior art uses an acousto-optic Q-switch which can ... Another approach uses electro-optic Q-switches in a pseudo cavity dumping ...
We report on a time-resolved measurement of self-amplified spontaneous emission free-electron laser (FEL) pulses. We observed that the spikes in such FEL pulses have an intrinsic positive chirp and the energy chirp in the electron bunch mapped directly into the FEL output. The measurement also provides rich information on the statistics of the FEL pulses.
Computer simulations and experiments indicate that we can shape the infrared picosecond pulses of the Mark III FEL in amplitude, frequency, and phase. Strongly modulated fundamental and second harmonic pulses have been generated by operating the Mark III FEL in the regime of strong sideband growth. In this paper, we present the results of simulations and experiments for second harmonic generation with fundamental inputs from 2 to 3 {mu}m.
We present a monolithic, self-starting, all-PM, stabilized Yb-fiber laser, pulse-compressed in a hollow-core PM photonic crystal fiber, providing the 370 fs pulses of 4 nJ energy with high mode quality.
The mz8310 device support module provides support for the following record types: event, pulseCounter, pulseDelay, and pulseTrain. No driver support is needed. Up to 4 mz8310 modules are supported. Each 8310 module contains 10 channels, which are identified as signals O,...9. Each channel is individually configurable. Each mz83 10 has two Am9513 Timing Controller chips. Each Am9513 has 5 counters.
Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.
The detection of explosives is a notoriously difficult problem, especially at stand-off distances, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring optimal dynamic detection to exploit the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity of explosives signatures while reducing the influence of noise and the signals from background interferents in the field (increase selectivity). These goals are being addressed by operating in an optimal nonlinear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked control and probe ...
The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as cryo-permanent magnets in potential applications ...
Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude ...
Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).
This book examines the nonlinear optical properties of laser materials. The physical radiation effects on laser materials are also considered. Topics considered include: nonlinear optical properties; nonlinear and harmonic generation materials; two-photon absorption; nonlinear refractive index; stimulated Raman scattering; radiation damage; crystals; and glasses.
The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, ...
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber ...
We propose a scheme of quantum computation with nonlinear quantum optics. Polarization states of photons are used for qubits. Photons with different frequencies represent different qubits. Single qubit rotation operation is implemented through optical elements like the Faraday polarization rotator. Photons are separated into different optical paths, or merged into a single optical path using dichromatic mirrors. The controlled-NOT gate between two qubits is implemented by the proper combination of parametric up and down conversions. This scheme has the following features: (1) No auxiliary qubits are required in the controlled-NOT gate operation; (2) No measurement is required in the course of the computation; (3) It is resource efficient and conceptually simple.
Because of limitation on neutron-incident data, it is difficult to obtain global optical model potential for neutrons. In contrast, there are some global optical model potentials for proton in detail. It is interesting to convert the proton-incident global optical potentials into neutron-incident ones. In this study we introduce (N-Z)/A dependent symmetry potential terms into the global proton-incident optical potentials, and then obtain neutron-incident ones. The neutron potentials reproduce total cross sections in an acceptable degree. However, a comparison with potentials proposed by other authors brings about a confused situation in the sign of the symmetry terms. (author).
It has been predicted for several years that light is focused (optically guided) as well as amplified by the electron beam in a free electron laser (FEL). The degree of focusing depends strongly on both electron beam and optical beam characteristics. In an FEL oscillator the degree of focusing varies with intracavity optical power during the macropulse. We report the first direct measurements of the evolution of transverse optical model size and shape between small signal and saturation in a short wavelength (Compton regime) FEL oscillator. The mode measurements on the Mark III FEL oscillator are shown to be consistent with theory, requiring both refractive and gain contributions to guiding. (orig.).
A fiber optic feedthrough module which comprises a metal sleeve, a fiber optic element extending through the sleeve in spaced relation thereto, and a tandem series of centrally-apertured mating annular sealant bodies of thermoplastic material surrounding the fiber optic element and compressed between it and the sleeve. The module is made by first providing a loose subassembly of a plurality of individual but interfitting sealant bodies on the fiber optic element and then inserting this subassembly into a metal sleeve, following by swaging the whole assembly which eliminates clearances and provides sealed interfaces between the various contacting components. (author).
Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...
The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, provides 5000 acre-ft of active storage volume ...
A new organic-inorganic hybrid membrane has been prepared with exceptional performance in dewatering applications. The only precursor used in the sol-gel synthesis of the selective layer was organically linked 1,2-bis(triethoxysilyl)ethane (BTESE). The microporous structure of this layer enables selective molecular sieving of small molecules from larger ones. In the dehydration of n-butanol with 5% of water, the membrane shows a high separation factor of over 4000 and ultra-fast water transport at a rate of more than 20 kg m{sup -2} h{sup -1} at 150C. This can be related to the high adsorption capacity of the material and the sub-micron thickness of the selective layer. The selectivity has now remained constant over almost one and a half years under continuous process testing conditions. Apart from the hydrothermal stability, the membrane exhibits a high tolerance for acid contamination. A slow performance decline in flux and separation factor is only observed at a ...
Topographic and optical patterns have been fabricated in a-SiC films with a focused high-energy (1 MeV) H"+ and He"+ ion beam and examined with near-field techniques. The patterns have been characterized with atomic force microscopy and scanning near-field optical microscopy to reveal local topography and optical absorption changes as a result of the focused high-energy ion beam induced modification. Apart of a considerable thickness change (thinning tendency), which has been observed in the ion-irradiated areas, the near-field measurements confirm increases of optical absorption in these areas. Although the size of the fabricated optical patterns is in the micron-scale, the present development of the technique allows in principle writing optical patterns up to the nanoscale (several tens of nanometers). The observed values of the optical ...
In this paper, molecular quantum computation is numerically studied with the quantum search algorithm (Grover's algorithm) by means of optimal control simulation. Qubits are implemented in the vibronic states of I_2, while gate operations are realized by optimally designed laser pulses. The methodological aspects of the simulation are discussed in detail. We show that the algorithm for solving a gate pulse-design problem has the same mathematical form as a state-to-state control problem in the density matrix formalism, which provides monotonically convergent algorithms as an alternative to the Krotov method. The sequential irradiation of separately designed gate pulses leads to the population distribution predicted by Grover's algorithm. The computational accuracy is reduced by the imperfect quality of the pulse design and by the electronic decoherence processes that are modeled by the non-Markovian ...
The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak ...
Sodium-dependent high-affinity choline uptake was measured in various regions of the brains of rats irradiated for 45 min with either pulsed or continuous-wave low-level microwaves (2,450 MHz; power density, 1 mW/cm2; average whole-body specific absorption rate, 0.6 W/kg). Pulsed microwave irradiation (2-microseconds pulses, 500 pulses/s) decreased choline uptake in the hippocampus and frontal cortex but had no significant effect on the hypothalamus, striatum, and inferior colliculus. Pretreatment with a narcotic antagonist (naloxone or naltrexone; 1 mg/kg i.p.) blocked the effect of pulsed microwaves on hippocampal choline uptake but did not significantly alter the effect on the frontal cortex. Irradiation with continuous-wave microwaves did not significantly affect choline uptake in the hippocampus, striatum, and hypothalamus but decreased the uptake in the frontal cortex. The ...
The US Department of Energy`s Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also ...
The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and ...
Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.
The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.
Measurements of low-energy (#approx#10"- "1"0 J) femtosecond laser pulse durations have been carried out on the basis of second-order autocorrelation function analysis. The scheme of non collinear second harmonic generation realized in KDP crystal has been used for increasing of the measurement contrast and accuracy. Proposed scheme can be used for measurements in wide enough ranges of laser pulse durations (from tens femto seconds to hundreds picoseconds) and energies. (authors)
Eight cross spiders (Araneus diadematus) were exposed overnight (16 h) during web-building activity to pulsed 9.6-GHz microwaves at average power densities of 10, 1, and 0.1 mW/sq. cm. (estimated SARs 40, 4, and 0.4 mW/g). Under these conditions, 9.6-GHz pulsed microwaves did not affect the web-spinning ability of the cross spider.
There is increasing demand to functionalize meso- and nano-porous materials by coating and make the porous substrate biocompatible or environment friendly. However, coating on a meso-porous substrate poses great challenges, especially if the pore aspect ratio is high. In the current work the pulsed laser deposition (PLD) method is used for coating Ni{sub 3}Al-based meso-porous membranes with diamond-like carbon (DLC) layers of high thickness homogeneity and adhesion. (orig.)
The possibility of radio galaxies being random sample of otherwise normal elliptical galaxies is tested. Starting with the observed optical luminosity functions for elliptical galaxies, it is shown that the probability of an elliptical forming a radio source is a continuous, increasing function of optical luminosity, precisely proportional to square of the optical luminosity of the galaxy. Once the probability function is fixed, the luminosity function of normal elliptical galaxies is used as input for Monte Carlo simulations that reproduce the distribution of radio galaxies in the radio-optical luminosity plane. Our results show that radio galaxies are luminosity biased, but otherwise random sample of elliptical galaxies. This unified view of radio and non-radio ellipticals also explains the well known difference of 0.5 mag in average optical luminosity between FRI and FRII radio ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)
Large optical surveys provide an unprecedented census of galaxies in the local Universe, forming an invaluable framework into which more detailed studies of objects can be placed. But how useful are optical surveys for understanding the co-evolution of black holes and galaxies, given their limited wavelength coverage, selection criteria, and depth? In this conference paper I present work-in-progress comparing optical and mid-IR diagnostics of three "unusual" low redshift populations (luminous Seyferts, dusty Balmer-strong AGN, ULIRGs) with a set of ordinary star-forming galaxies from the SDSS. I address the questions: How well do the mid-infrared and optical diagnostics of star formation and AGN strength agree? To what extent do optical surveys allow us to include extreme, dusty, morphologically disturbed galaxies in our "complete" census of black hole-galaxy co-evolution?
A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}
... main in this state only for 10-8 secs., after which they decay to the meta- stable state (fluorescent level) because of spontaneous radiation or other ...
... at compositions below -AlP 4 the films were still unstable, hydrolysing in room air, and the long term stability of higher aluminium phosphides is in ...
This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N{sub 2} : H{sub 2}) and pulsed ratio (pulse on/off time ratio)
This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N_2 : H_2) and pulsed ratio (pulse on/off time ratio).
To measure electron reactions on a picosecond timescale the investigators developed a picosecond pulse-conductivity technique, which makes use of the electron fine-structure pulses of our LINAC (pulse width 25 vs FWHM) to produce excess electrons and now detects changes in sample conductance under optimum conditions with an instrumental response of 18 ps. This resolution is in agreement with a theoretical estimate. This technique has been successfully applied to study excess electron reactions in solvents covering a mobility range from 0.24 to 100 cm/sup 2/V/sup -1/s/sup -1/; extension to lower mobility liquids seem possible.
A three-dimensional numerical study is performed to explore the effect of pulsed spanwise-periodic surface thermal perturbation (also denoted as thermal bump) in a Mach 1.5 flat plate laminar boundary layer. A high-resolution upwind-biased Roe method is used with the compressive Van Leer harmonic limiter on a suitably refined mesh. The dependence of flow stability characteristics on the variation of thermal bump geometry (shape and dimension) and pulsing properties (disturbance amplitude and frequency) is assessed. It is shown that the finite-span thermal bumps generate streamwise vortices. When the thermal bump is pulsed, vortex shedding is observed, and the streamwise vorticity grows with the downstream distance. Analysis of the integrated disturbance energy indicates that the streamwise...
A flowing carbon dioxide laser was operated at low pressures up to 4 torr. Excitation of the laser was provided using various combinations of direct current (DC), pulsed microwave, and continuous wave (CW) microwave excitation. The microwaves were in the 2.45 GHz band and were coupled into the gas using a slow-wave interdigital transmission line. Laser output of 25 milliwatts (mw) was achieved using a DC discharge only. A combination of a DC discharge and pulsed microwaves doubled the output and resulted in some modulation. Changing the laser gas mixture and pulsed microwave field characteristics allowed some flexibility in the modulation. Lasing was not achieved with excitation from the CW microwaves alone due to the formation of localized discharges. Using pulsed microwaves to sustain the discharge and CW microwaves to pump the laser, a quasi-CW output of 55 mw was achieved.
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries
In the rf-driven free-electron laser (FEL) at the Los Alamos National Laboratory, there are two pulsed-power rf modulators as sources for two tandem, side-coupled 20-MeV linear accelerators. The rf power used to control the cavity fields is supplied by two 5.5-MW modulating anode klystrons operating at a center frequency of 1300.2 MHz. The modulation of the 125 kV klystron is achieved by using a triode switch tube that provides a pulse width up to 300 ..mu..s and a pulse repetition rate up to 10 Hz. This paper describes the present configuration of these two duplicate systems and presents plans for meeting the requirements of future rf FEL experiments at Los Alamos. 12 refs., 5 figs.
Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.
Electrically triggered action potentials in the giant alga Chara corallina are associated with a transient rise in the concentration of free Ca(2)+ in the cytoplasm (Ca(2)+(cyt)). The present measurements of Ca(2)+(cyt) during membrane excitation show that stimulating pulses of low magnitude (subthreshold pulse) had no perceivable effect on Ca(2)+(cyt). When the strength of a pulse exceeded a narrow threshold (suprathreshold pulse) it evoked the full extent of the Ca(2)+(cyt) elevation. This suggests an all-or-none mechanism for Ca(2)+ mobilization. A transient calcium rise could also be induced by one subthreshold pulse if it was after another subthreshold pulse of the same kind after a suitable interval, i.e., not closer than a few 100 ms and not longer than a few seconds. This dependency of Ca(2)+ mobilization on single and double pulses ...
Electrically triggered action potentials in the giant alga Chara corallina are associated with a transient rise in the concentration of free Ca2+ in the cytoplasm (Ca2+cyt). The present measurements of Ca2+cyt during membrane excitation show that stimulating pulses of low magnitude (subthreshold pulse) had no perceivable effect on Ca2+cyt. When the strength of a pulse exceeded a narrow threshold (suprathreshold pulse) it evoked the full extent of the Ca2+cyt elevation. This suggests an all-or-none mechanism for Ca2+ mobilization. A transient calcium rise could also be induced by one subthreshold pulse if it was after another subthreshold pulse of the same kind after a suitable interval, i.e., not closer than a few 100 ms and not longer than a few seconds. This dependency of Ca2+ mobilization on single and double pulses can be simulated by a ...
Effect of Abdominal Active Can on DFTs. Introduction: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. Methods and Results: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ...
Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)
... The three meteorological rocket systems, in order of ... IC3 and IC4 divides the incoming clock pulses f ... at the junction of the temperature sensor and R ...
The heating and current drive systems are being developed to support long pulse, high {beta}, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.
The heating and current drive systems are being developed to support long pulse, high #beta#, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.
... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...
Effects of 2450-MHz circularly polarized microwave irradiation on central nervous system functions were studied. Pulsed (microsecond, 500 pps) microwaves decreased high-affinity sodium-dependent choline uptake in the hippocampus and frontal cortex of the rat. The effect on hippocampal choline uptake was blocked by pretreatment with narcotic antagonists. Continuous-wave microwaves of the same power density decreased choline uptake in the frontal cortex only. Furthermore, it was found that the effects of pulsed microwaves on central cholinergic activity are classically conditionable to cues in the exposure environment. The hypothesis that some of the neurological effects of pulsed microwave irradiation are caused by its effect on the auditory system was investigated. Effects of pink noise and pulsed microwaves were compared.
During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-#mu#m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.
During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-{mu}m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.
PurposeA time-course analysis of gene regulation in the adult rat retina after intraorbital nerve crush (IONC) and intraorbital nerve transection (IONT).MethodsRNA...Full Text Available
In a new approach to medical computer based education (CBE) students at several U.S. and Canadian health professions schools have been using an optical videodisc under computer control to study basic...Full Text Available
Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.
Optical absorptance spectra of A-15 compounds were taken using a calorimetric technique in the range 0.2 eV to 4.0 eV. Thermomodulation spectra were taken on several A-15 sputtered films.
Optical absorptance spectra of A-15 compounds were taken using a calorimetric technique in the range 0.2 eV to 4.0 eV. Thermomodulation spectra were taken on several A-15 sputtered films.
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available
PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
The utility of a two-photon optical fiber fluorescence probe (TPOFF) for sensing and quantifying tumor fluorescent signals was tested in vivo. Xenograft tumors were developed in athymic mice using MCA207...Full Text Available
Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
Recently, organic semiconducting materials have gained a broad interest due to their potential for organic electronic devices such as organic light emitting diode (OLED), organic photovoltaic devices and organic field-effect transistors (OFETs). Optical properties of organic semiconducting materials are important for practical application. For example, the power conversion efficiency of organic photovoltaic devices is mainly affected by absorption properties of organic materials. Proton irradiation is one of the efficient methods to change the optical properties of organic materials. In this paper, we investigate the changes of optical properties of various polymers using the proton irradiation.
... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...
... concentrated on the construction of switches using fiber ... been chosen for a switch realized in ... of these techniques using acousto-optic modulators or ...
A monolithic micromachined waveguide device or devices with low-loss, high-power handling, and near-optical frequency ranges is set forth. The waveguide and integrated devices are capable of transmitting near-optical frequencies due to optical-quality sidewall roughness. The device or devices are fabricated in parallel, may be mass produced using a LIGA manufacturing process, and may include a passive component such as a diplexer and/or an active capping layer capable of particularized signal processing of the waveforms propagated by the waveguide.
Using a sensitive optical wavelength modulation technique the surface-plasmon excited on a gold grating surface immersed in sulfuric acid is studied at the same time as cyclic voltammetry is undertaken. Because of the optical sensitivity of the modulation technique significant optical effects are observed at potentials well below those at which any gross oxidation effects occur.
High purity MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA to very high exposure have been examined by three techniques to determine changes in their optical properties. Significant changes were observed in optical absorption, photoluminescence and radioluminescence.
A method for bistable storage of binary optical information includes an antiferroelectric (AFE) lead lanthanum zirconate titanate (PLZT) layer having a stable antiferroelectric first phase and a ferroelectric (FE) second phase obtained by applying a switching electric field across the surface of the device. Optical information is stored by illuminating selected portions of the layer to photoactivate an FE to AFE transition in those portions. Erasure of the stored information is obtained by reapplying the switching field.
We propose a scheme able to generate stationary continuous variable entanglement between an optical and a microwave cavity mode by means of their common interaction with a micro-mechanical resonator. We show that when both cavities are intensely driven one can generate bipartite entanglement between any pair of the tripartite system, and that, due to entanglement sharing, optical-microwave entanglement is efficiently generated at the expense of microwave-mechanical and opto-mechanical entanglement.
A new dual focal point electro-optic lens that is switchable to focusing and unfocusing is proposed and successfully demonstrated. This electro-optic lens is constructed by coating transparent fine electrodes in the Fresnel-zone plate onto a PLZT ceramic plate. Its focal length changes from 1.25 m to infinity binary at 515 nm with the external voltage of 210 V. PMID:20725208
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)
An experimental study of second harmonic generation in a copper-vapor pulsed laser with an ADP crystal is presented. The ratio of the conversion into the second harmonic is found to depend on the average power of the exciting radiation. The maximum conversion ratio was 8.5%. Thermal self-defocusing is the main obstacle to obtaining high average powers at the double frequency.
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
Saturation of the absorption of hot CO/sub 2/ by 1.6 ns P(18) and P(20) laser pulses at 10.6 ..mu..m has been measured. Coherent propagation calculations with no fitting parameters are in good agreement with the data and are consistent with a substantial hot-band contribution to the P(20) saturation.
The author is exploring the efficiency of pulsed plasma processing in the removal of nitrogen dioxide, nitrogen oxide, and other pollutants. This process uses an electrical discharge to create chemical radicals from air molecules. These radicals can react with pollutants and form harmless compounds. Additives such as hydrocarbons are also used to improve the efficiency of the removal. The efficient removal of nitrogen dioxide has required the presence of dilute aqueous solution of ammonia.
Based on the nonlinear dispersion relation of electromagnetic wave in relativistic plasma, the nonlinear controlling equation for linearly polarized mode is obtained using Karpman's method. The modulation instability of intense laser pulse propagating through relativistic plasma is analyzed and the modulation instability growth rate as a function of perturbation wave number for laser beam propagating through relativistic plasma is given. (authors)
This paper summarizes a method to evaluate the possible effects of magnetohydrodynamic-electromagnetic pulse (MHD-EMP) on power systems. This method is based on the approach adapted to study the impact of geomagnetic storms on power systems. The paper highlights the similarities and differences between the two phenomena. Also presented are areas of concern which are anticipated from MHD-EMP on the overall system operation. 12 refs., 1 fig.
The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.
The paper presents a description of the physical processes governing the variations of the pulse rise-time which occur during the operation of the proportional counter and are due to varying either the count rate or the applied voltage. On the basis of the rise-time concept the differences in the count rate effect observed in various types of proportional counters are discussed.
Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)
This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The ...
Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.
Isotopically selective IR multiphoton dissociation of molecules (SF_6, CF_3I) in a pulsed gas-dynamic flow interacting with a solid surface was studied for the first time. A noticeable (severalfold) increase in the yield of products (compared to excitation of molecules in an unperturbed flow) without a substantial decrease in the selectivity of the process was observed. Possible reasons for the effect are discussed. (laser applications and other topics in quantum electronics)
We have developed a novel insulator concept that involves the use of alternating layers of conductors and insulators with periods less than 1 mm. We have demonstrated that these structures perform 2 to 5 times better than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present new testing results showing exceptional behavior at DC, with gradients in excess of 110kV/cm in vacuum.
A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.
Implementation of quantum logical gates for multilevel systems is demonstrated through decoherence control under the quantum adiabatic method using simple phase modulated laser pulses. We make use of selective population inversion and Hamiltonian evolution with time to achieve such goals robustly instead of the standard unitary transformation language. (letter to the editor)
In this paper, finite-difference time-domain method is used to research the transient electromagnetic pulse (EMP) coupling to the cylinder object which is shielded in another shielding cavity with a hole numerically. The different coupling effectiveness of three transient EMP is simulated. The distribution of the electric field in the shielding cavity and the current on the cavity are researched. The shielding effectiveness is evaluated. (authors)
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
The alloying of steel surface with aluminum (Al) using Microsecond-pulsed Intense Electron Beams (MIEB-Al) was developed and optimized in order to be used for improving the corrosion resistance of the 316, 1.4970 and T91 steels, exposed to liquid Pb and Pb-Bi-eutectic. The procedure consists in two steps: (i) coating the steel surface with Al or an Al-containing alloy layer and (ii) melting the coating layer and the steel surface layer using intense pulsed electron beam. In order to cover the steel surface with an homogeneous and crack-free Al-alloyed layer, the following experimental conditions are required: Al coating thickness range 5-10mm, electron kinetic energy 120keV; pulse duration 30ms; energy density 40-45J/cm2; number of pulses 2-3. Using the mentioned procedure, the corrosion r...
We present computer modeling along with experimental data on the formation of sharp conical tips on silicon-based three-layer structures that consist of a single-crystal Si layer on a 1 {mu}m layer of silica on a bulk Si substrate. The upper Si layers with thicknesses in the range of 0.8-4.1 {mu}m were irradiated by single pulses from a KrF excimer laser focused onto a spot several micrometers in diameter. The computer simulation includes two-dimensional time-dependent heat transfer and phase transformations in Si films that result from the laser irradiation (the Stefan problem). After the laser pulse, the molten material self-cools and resolidifies, forming a sharp conical structure, the height of which can exceed 1 {mu}m depending on the irradiation conditions. We also performed computer simulations for experiments involving single-pulse irradiation of bulk silicon, reported by other groups. We discuss conditions under ...
Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO_2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water was waved by corona ...
Up to now the long range filaments have been considered as a balance between Kerr focusing and defocusing by plasma generation in the nonlinear focus. However, it is difficult to apply the above explanation of filamentation in far-field zone. There are basically two main characteristics which remain the same at these distances - the super broad spectrum and the width of the core, while the power in a stable filament drops to the critical value for self-focusing. At such power the plasma and higher-order Kerr terms are too small to prevent self-focusing. We suggest here a new mechanism for stable soliton pulse propagation in far-away zone, where the power of the laser pulse is slightly above the critical one, and the pulse comprises super-broad spectra. For such pulses the diffraction is not paraxial and an initially symmetric Gaussian pulse takes parabolic form at several ...
In this paper, we report an optical fiber sensor for measuring temperature based on bimetallic concept. The sensor is designed by following the basic principle of Fabry-Perot interferometer and theoretical detail of the sensor has been outlined here with a numerical study. An important feature of the proposed sensor is that the fabrication will be done on a commercial multimode optical fiber. The Micro-Electro-Mechanical Systems (MEMS) based fabrication process could be performed directly on a multimode optical fiber end face which will eliminate the need for adhesive in packaging. The sensor could be fabricated as sensor arrays for micro level applications. The potential application of the proposed optical sensor includes biomedical applications, nano research, microfluidics, and other ME...
Plasma polymerization of aniline is carried out in a radiofrequency plasma reactor and the effect of polymerization time is examined in the structural, optical and optoelectronic properties of deposited films. Conjugated structures of polyaniline like films are obtained with unique and broad optical absorption band in the ultraviolet and entire visible region. The width of the absorption band increases and hence the optical band gap decreases with polymerization time. The optical constants are extracted by Swanepoel method and the optical dispersion parameters are determined by employing the Wemple-DiDomenico single oscillator model. The films exhibit similar thermal stability in air and argon atmosphere in the region of interest for optoelectronic applications. The photoluminescence study...
A previous analysis aimed at underlining the importance of the relativistic electron beam quality for the performances of a Free Electron Laser (FEL) is continued in the paper by the study of the influence of the undulator field (wiggler) parameters and of the optical beam (and/or optical cavity) quality on the operation of a FEL. The importance of parameters such as K, #lambda#_u, g of the undulator, F, P_L, #nu#_c of the optical beam, and L, L_o_p_t and L_c_r of the optical cavity for the characteristics of the input radiation as P_o_u_t, G_o_p_t, and #eta# are analyzed and some relations between these parameters that will give the possibility to estimate the corresponding values are given. Some proposal for the design of a compact FEL in IR-spectral region, with #lambda# #approx# 230 #mu#m are given. (Author).
Until recently, the wavelength-division-multiplexed (WDM) transmission system has reached record capacities and distances due to innovations such as FEC (Forward Error Correction), distributed Raman amplification, new transmission fiber and advanced optical format. Optical-communication systems exclusively employed conventional On-Off Keying signals in either Non-Return-To-Zero (NRZ) or Return-To-Zero (RZ) format. Recently a number of advanced modulation formats have attracted attention. Some of these formats carry information through On-Off-Keying but also modulate the optical phase in order to enhance the robustness of signal to chromatic dispersion, optical filtering and non-linearities. Through extensive sets of simulation results, we showed that it is possible to replace a channel wit...
TiO{sub 2} is a vital material in several technologies including, photocatalysis, gas sensing, biomaterials and optical coatings. Among the several crystal structures of this oxide, rutile has the highest density and microhardness, the highest index of refraction and the highest temperature stability. The processing of dense polycrystalline materials often includes the addition of a liquid-forming phase at higher temperatures. This technique is known as liquid-phase sintering and has been studied extensively. Rutile boundaries containing an amorphous phase have been used to study boundary migration and grain-boundary grooving. Visible-light (VLM), scanning electron (SEM) and transmission electron microscopy (TEM) in addition to electron-backscatter diffraction (EBSD) and a focused-ion beam (FIB) tool were used to characterize boundary migration in rutile. EBSD analysis was carried out on a Philips XL30 FEG SEM equipped with a DigiView 1612 high-resolution, ...
An International Workshop on Metrology for X-ray and Neutron Optics has been held March 16-17, 2000, at the Advanced Photon Source, Argonne National Laboratory, near Chicago, Illinois (USA). The workshop gathered engineers and scientists from both the U.S. and around the world to evaluate metrology instrumentation and methods used to characterize surface figure and finish for long grazing incidence optics used in beamlines at synchrotrons radiation sources. This two-day workshop was motivated by the rapid evolution in the performance of x-ray and neutron sources along with requirements in optics figure and finish. More specifically, the performance of future light sources, such as free-electron laser (FEL)-based x-ray sources, is being pushed to new limits in term of both brilliance and coherence. As a consequence, tolerances on surface figure and finish of the next generation of optics are expected to ...
We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an ...
Cancer is a severe threat to human health. Early detection is considered the best way to increase the chance for survival. While the traditional cancer detection method, biopsy, is invasive, noninvasive optical diagnostic techniques are revolutionizing the way that cancer is diagnosed. Reflectance spectroscopy is one of these optical spectroscopy techniques showing promise as a diagnostic tool for pre-cancer detection. When a neoplasia occurs in tissue, morphologic and biochemical changes happen in the tissue, which in turn results in the change of optical properties and reflectance spectroscopy. Therefore, a pre-cancer can be detected by extracting optical properties from reflectance spectroscopy. This dissertation described the construction of a fiberoptic based reflectance system and the development of a series of modeling studies. This research is aimed at establishing an improved understanding of ...
Pulses are rich in nutrients. The existence of anti-nutritional components and the length of time required for preparation have, however, limited their frequency of use compared to recommended intake levels. Anti-nutritional components in pulses can be largely removed by heat treatment. Additionally pre-treatment of pulses with heat and processing of seeds into flour could further enhance their use by decreasing processing and preparation times. In this study, trypsin inhibitor activity, functional properties, and microstructural characteristics of flours prepared from different varieties of lentil, chickpea, and pea as affected by roasting and boiling were evaluated. Both thermal treatments resulted in significant reduction (p<0.05) in trypsin inhibitor activity ranging from -95.6% to -37...
Improved biosorption of uranium by Kluyveromyces marxianus IMB3 biomass was achieved by increasing the electric field strength of delivered pulses from 1.25kV/cm to 2.5kV/cm. Although this had little or no effect on the maximum biosorption capacity (q(max)), at low concentrations of uranium the amount bound to the biomass increased from 70 to 140mg uranium/g biomass. Significant increases in the maximum biosorption capacities (119-180 mg uranium/g biomass) were observed when the pulse field strength was increased from 2.5kV/cm to 3.25kV/cm. (Author).
The production of retrograde amnesia (RA) upon electron-beam exposure was investigated. RA production was evaluated using a single-trial avoidance task for 10, 1, and 0.1 microsecond pulsed exposures. The dose-response curve obtained at each pulse duration showed significant RA production. The most effective dose range was 0.1-10 rad at a dose rate of 1,000,000 rad/sec. By employing a 10 rad (1,000,000 rad/s) pulse, a memory loss of the events occurring in the previous 4 sec was demonstrated. The conclusion was that the RA effect might be due to sensory system activation which provided a novel stimulus that masked previous stimuli.
The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).
The Pulsed Lepton Source (PLS) project opens some exciting possibilities for muon and neutrino physics . The PLS would use the 0.25 4s proton pulses from the upgraded Proton Storage Ring (PSR) at LAMPF to create short, intense bursts of muons and neutrinos. The neutrino beam would be used for a few fundamentally important weak interaction physics experiments. The muon beams would find a wide variety of applications in both fundamental and applied'' muon physics areas. After a brief discussion of the physical layouts of the PSR and the proposed PLS in Sec. 2 and muon area in Sec. 3, we note some of the muon physics experiments and areas that could advantageously be addressed at the PLS in Secs. 4 and 5, and conclude in Sec. 6.
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
Conductive TiN/Si_3N_4 ceramic composites were processed by electrical discharge machining (EDM) and their microstructure and conductivity were investigated. The whole process of tool electrode wear is evaluated by sinker-EDM. The machined surfaces of TiN/Si_3N_4 ceramic composites were examined by scanning electron microscopy (SEM) and profilometry to determine the surface finish. The electrode wear rate of brass is higher than copper electrode for all EDMed tests. The surface texture was found to have greater dependence on pulse energy. It was observed that the sinker-EDM at higher pulse energy caused severe microdamage in the surface. The surface roughness (Ra) values also increase with increasing pulse energy.
Ferroelectric disks, coated with proper electrodes, can easily produce a dense plasma cloud when excited with a high-voltage pulse. This plasma can be a source of either electrons or ions depending on the sign of the extracting field set in front of the disk. We present the behavior of the disks operating at high frequency as emitters of both electrons and ions in two experimental configurations: (a) without and (b) with two screening grids. These two screening grids are inserted when the plasma must be confined within the cathode region. The system is capable of providing ion pulses of a few hundred milliamperes, whose length can range from a hundred nanoseconds to dozen microseconds. The electron pulses of energetic electrons have typically an amplitude higher than a couple of amperes. Tests at MHz repetition rate were positive as for stable operation.
The nature of the `inner engine' that accelerate and collimate the relativistic flow at the cores of GRBs is the most interesting current puzzle concerning GRBs. Numerical simulations have shown that the internal shocks' light curve reflects the activity of this inner engine. Using a simple analytic toy model we clarify the relations between the observed $ \\gamma $-rays light curve and the inner engine's activity and the dependence of the light curves on the inner engine's parameters. This simple model also explains the observed similarity between the observed distributions of pulses widths and the intervals between pulses and the correlation between the width of a pulse and the length of the preceding interval. Our analysis suggests that the variability in the wind's Lorentz factors arises due to a modulation of the mass injected into a constant energy flow.
We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.
One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.
A pillbox RF output window was developed for the L-band pulsed klystron for the Japanese Hadron Project (JHP) 1-GeV proton linac. The window was designed to withstand a peak RF power of 6 MW, where the pulse width is 600 {mu}sec and the repetition rate is 50 Hz. A high power model was fabricated using an alumina ceramic which has a low loss tangent of 2.5x10{sup -5}. A high power test was successfully performed up to a 113 kW RF average power with a 4 MW peak power, a 565 {mu}sec pulse width and a 50 Hz repetition rate. By extrapolating the data of this high power test, the temperature rise of the ceramic is estimated low enough at the full RF power of 6 MW. Thus this RF window is expected to satisfy the specifications of the L-band Klystron. (author).
A voice activated garage door opener was designed for a handicapped person to open a garage door without assistance. This design uses speech recognition of one word. The activating word that was chosen is "up". The frequency spectrum of "up" was captured on a soundboard and is the basis of this design. Filters are used to pick out three frequency bands in this spectrum. The output signals from these filters are then compared to three threshold voltages using voltage comparators. If the output signals from the filters are above the threshold voltages, the comparators go high. Monostable multivibrators are used on the output of the comparators to lengthen the high pulses. When all of the pulses from the monostable multivibrators are high at the same time, an AND gate output goes high. This high pulse activates the door opener. PMID:8329601
The design and operating principle of a small (50 mm in diameter and 100 mm in height) ???-73C vacuum spark gap are described. It is shown that it can be efficiently switched using a control circuit with a low (?900 V) supply voltage, which is based on an inductive energy storage and a diode opening switch that forms a high-voltage igniting pulse with a rise time of nanosecond duration. The ???-73C switching process is investigated at different rise times of igniting voltage pulses and different igniting current amplitudes. The results of tests of the spark gap operating in regimes of switching current pulses with an amplitude of 12 kA and a rise time of 800 ns are presented.
This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.
A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are described. copyright 1997 American Institute of Physics.
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...
The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. ...
Instrumentation research to study the feasibility of using optical data processing techniques to solve real-time pattern recognition problems for high energy physics experiments is now in its second year. During the past year, a prototype optical processor for use in BNL Experiment 702 was conceived and designed, using test data from the experiment and simulating the optical processor in the computer. A number of technical studies have been made, mostly relating to the selection of the optical filter for the processor. Comparisons between natural and synthetic holograms, both bleached and unbleached, have been made. We conclude from these tests that the kinoform, a computer-generated phase hologram, is the optimal choice for this processor. A new method for producing the kinoform has been tried by this group with encouraging results. The optical design for the prototype processor is ...
ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were proposed to extend the rectennas into the IR and ...
In this article we describe an optoelectronic sensor for assessing the level of light petrochemical products in technological tanks at the oil refineries. This sensor employs the multi-element vertical array of discrete micro- optical refractometric transducers. The transducers are made of silica glass and have the conical shape. In the air, each transducer operates as a tiny retro-reflector that optically couple together two multimode optical fibers. The optical coupling in the transducer is due to the internal reflection at the conical surface. The amount of the coupling depends on the refractive index of the surrounding media. In a fluid, the total internal reflection vanishes and the coupling becomes negligibly small. The number of immersed transducers is a measure of the fluid level in the reservoir. Because of the significance of the transducer transmission function, it is evaluated in detail ...
As a result of health and safety issues surrounding the use of radioactive materials on coated optical components, there has been renewed interest in coating materials whose optical and mechanical properties approach those offered by their radioactive counterparts. Due to the radioactive nature of ThF{sub 4} and its widespread use in optical coatings, the coating industry is examining other low index and non-radioactive fluorides as possible alternatives. In this paper, the authors present the results of an experimental study on the optical and mechanical properties of thermally evaporated ThF{sub 4}, DyF{sub 3}, CeF{sub 3}, LiF, HfF{sub 4}, IRX, and IRB thin films, where the materials were deposited at different substrate temperatures. The objective is to examine this series of fluorides under comparable deposition conditions and with respect to such material properties as: n and k, film stress, and ...
The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...
The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National ...
Haemangiomas usually develop within the first few weeks of life, most regressing spontaneously before the age of 7 years. Some may ulcerate or compromise a vital function, in which case systemic corticosteroids, surgery or radiotherapy may be helpful. All of these treatment modalities are associated with significant morbidity. Treatment with the 585 nm flashlamp pulsed dye laser is safe and effective in the management of superficial vascular malformations. We report seven patients, under 12 months of age, who presented with proliferative haemangiomas, causing functional impairment. Ulcerated lesions were present in four patients. The patients were treated with the 585 nm pulsed dye laser (fluences 7.0-9.25 J/cm2), at intervals of 4-8 weeks. All of the lesions showed a significant reduction in size, together with improvement in the colour and integrity of the overlying skin. Treatment with the 585 nm pulsed dye laser should ...
Using standard brass alloy samples, an approach to reduce the laser-induced breakdown spectroscopy measurement uncertainty was tested and proved. Two important parameters for plasma characterization, the plasma temperature and the electron density, were applied to minimize the signal uncertainties due to uncontrollable experimental parameter variations. Results show that for the pulse-to-pulse analysis, the signal fluctuations can be significantly reduced by utilizing the plasma characteristic information. The major source for the single pulse fluctuations is the redistribution of the characteristic line at different temperatures according to the Boltzmann distribution under LTE. The change of the degree of ionization also contributes to the signal fluctuations. For the multi-pulse analysis, due to the nonlinear relationship between the plasma temperature and the line intensity, it is not applicable to utilize the Boltzmann ...
Analysis of the pulsed-field gel electrophoretic profiles of 82 pneumococcal isolates with reduced susceptibility to ciprofloxacin (RSC) and of 90 co-occurring susceptible isolates indicates a considerable...Full Text Available
In systems of fast decimal counters, there are three problems to be resolved: to study a bistable having a short switching time, to form with the aid of three bistables a circuit divisible by 5, and to normalize the input pulses. The solutions to these problems for the nonsecond scaler are presented. (J.S.R.)
The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...
Technologies for materials, processes, and manufacturing that will provide safe, .... advanced energy conversion techniques, and pulsed inductive and ... duration antimatter storage and transportation, and methods for utilizing ...... EVA systems can be found in the EVA Technology Roadmap of the EVA Project Plan. ...
The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which enhances the neutron exposure capabilities over those of the former ACPR Facility.
The traveling-wave mode in ring lasers is achieved by two methods: by a reversing mirror, and by using an intracavity nonreciprocal device. This paper is devoted to realization of the traveling-wave mode in a mode-locked YAG-Nd ring laser by a method proposed by Tomov et al. This method uses two intracavity Q-switches. In mode-locked operation, pulses are generated that can be considered short compared with the period of modulation T = L/C (where L is the length of the perimeter of the cavity). Analysis shows that if the shift of the switching signals corresponds to the time of travel of a light pulse between Q-switches, the pulse in one direction will pass the Q-switches at instants of zero losses, while losses in the other direction will be maximized for a distance between Q-switches of L/4, and will be zero for a distance L/2. Experimental verification of the proposed method gave unidirectional lasing with an intensity ...
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
A case of {beta}-thalassemia intermedia with spinal cord compression due to extramedullary hematopoiesis, which was successfully treated by blood transfusion, is presented. Emphasis was made on the MRI appearance of extramedullary hematopoiesis on different pulse sequences. The theories that aimed to explain the involvement of the epidural space by extramedullary hematopoiesis are discussed.
twenty 350 V, 2.5 mF aluminum electrolytic capacitors with 10.8 mH inductors made of multi-strand wire. The PFN discharge was controlled using an silicon ...
The photon rupture method, by which oxide film and metal are removed by focused pulsed Nd-YAG laser beam irradiation, was applied to form artificial micro-pits in Zn-5 mass% Al alloy-coated steel. The zinc alloy-coated layer was removed by pulsed laser irradiation treatment for about one second in a neutral buffer solution with NaCl. The rest potential transient with the laser treatment was measured. In the early stage of the laser treatment the rest potential of zinc alloy-coated steel changed to the negative direction immediately after every irradiation of a laser pulse and then returned to the previous value. However, after the steel substrate was exposed to the solution, the rest potential moved to the positive direction immediately after every irradiation of a laser pulse and then returned to the previous value. The amplitude and duration of the potential change after the laser irradiation ...
The use of dendritic cells (DCs) as a cellular adjuvant is a promising approach to the immunotherapy of cancer. It has previously been demonstrated that DCs pulsed ex vivo with Toxoplasma gondii...Full Text Available
Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available
First structural wall material (FSW) materials in inertial fusion energy (IFE) power reactors will be irradiated under typical repetition rates of 1-10 Hz, for an operation time as long as the total reactor lifetime. The main objective of the present work is to determine whether a continuous-pulsed (CP) approach can be an efficient method in modeling the pulsed activation process for operating conditions of FSW materials. The accuracy and practicability of this method was investigated both analytically and (for reaction/decay chains of two and three nuclides) by computational simulation. It was found that CP modeling is an accurate and practical method for calculating the neutron-activation of FSW materials. Its use is recommended instead of the equivalent steady-state method or the exact pulsed modeling. Moreover, the applicability of this method to components of an IFE power plant subject to repetition rates lower than ...
The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.
The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.
Normal reproductive functioning may require secretion of LH independently of FSH. Variation in GnRH pulse frequency and inhibin negative feedback are mechanisms for differential gonadotropin regulation;...Full Text Available
Atomic oxygen is measured in a pulsed dielectric barrier discharge (DBD) using two-photon absorption laser-induced fluorescence (TALIF). The ground-level atomic oxygen is excited to the 3p "3P state by two-photon absorption at 226 nm. Negative (-40 kV) or positive (+30 kV) pulsed DBD occurs in an O_2-N_2 mixture at atmospheric pressure. The pulse width of the DBD current is approximately 50 ns. The TALIF experiment shows that the decay rate of atomic oxygen increases linearly with O_2 concentration. This result proves that atomic oxygen decays mainly by the third-body reaction, O + O_2 + M #-># O_3 + M. The rate coefficient of the third-body reaction is estimated to be 2.2 x 10"-"3"4 cm"6 s"-"1 in the negative DBD and 0.89 x 10"-"3"4 cm"6 s"-"1 in the positive DBD. It is shown that the decay rate of atomic oxygen increases linearly with humidity. This can explain the well-known fact that ozone production in DBD is ...
A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available
In a mass casualty situation, medical personnel at the disaster site and other field treatment settings may need to monitor the vital signs of hundreds of seriously injured patients with minimal staffing....Full Text Available
The effects of thiol-specific reagents on the amplitude of the electro-olfactogram (E.O.G.) responses elicited from frog olfactory mucosa by pulses of odorant vapours was studied. The impermeant thiol-specific...Full Text Available
In this work, the effects of the focus ion beam (FIB) milling process on the optical properties of semiconductor nanostructures were investigated. With this aim, a sensitive materials system based on InGaAs/GaAs quantum dots with well known and excellent optical properties was selected for the FIB treatment. The FIB technique was used to locally remove a metallic mask deposited on top of the quantum dot sample. The photoluminescence (PL) signal, collected from the circular openings, was used to infer the possible damage effects of the ion beam on the properties of the dots.
The optical pressure exerted o a thin film, which is locked in the evanescent field formed at the plane interface with a totally-reflected Gaussian beam, is investigated. Some calculations of the pressure on the film caused by the evanescent field are presented in the different conditions of film thickness, film position, incident angle and polarization of a gaussian beam. The results show that the pressure exertion on the thin film can change from pushing to pulling as the parameters are varied. In particular, we find that the direction of optical pressure can act oppositely at the different positions of the film surface in the evanescent field.
One of the major scientific and technological challenges for the production of flexible organic electronic devices is the device protection against atmospheric molecule permeation, which causes corrosion reducing its operation and lifetime. In this work, Spectroscopic Ellipsometry has been implemented to investigate the influence of silicon dioxide nanoparticles on the optical properties of hybrid polymers. The spectra analysis revealed valuable information about the electronic and vibrational response as well as the cross-linking mechanisms of these materials. The correlation of the optical properties with the synthesis parameters and the barrier response will contribute towards their optimization in order to be used as high barrier coatings for flexible organic electronics applications.
Individual laser cooled atoms are delivered on demand from a single atom magneto-optic trap to a high-finesse optical cavity using an atom conveyor. Strong coupling of the atom with the cavity field allows simultaneous cooling and detection of individual atoms for time scales exceeding 15 s. The single atom scatter rate is studied as a function of probe-cavity detuning and probe Rabi frequency, and the experimental results are in good agreement with theoretical predictions. We demonstrate the ability to manipulate the position of a single atom relative to the cavity mode with excellent control and reproducibility.
The subband structure and optical properties of a cylindrical quantum well wire under intense non-resonant laser field are investigated by taking into account the correct dressing effect for the confinement potential. The energy levels and wave functions are calculated within the effective mass- approximation using a finite element method. It is found that the absorption coefficient and the saturation intensity are strongly affected by the laser amplitude and frequency as well as by the incident light polarization. As a key result, a large anisotropy in the linear and nonlinear optical absorptions for very intense laser field is predicted. These effects can be useful for the design of polarization sensitive devices.
This paper reports on the results of experiments into efficient higher-order anti-Stokes Raman conversion of tunable short-pulse XeCl laser radiation. The maximum output energy of the pumping laser, in which the radiation of a frequency-doubled dye laser is amplified by two XeCl laser amplifiers, is 55 mJ with a pulse duration of 1 ns FWHM. Using hydrogen gas as a Raman medium, a series of anti-Stokes lines up to the 12th order (121.5 nm) is generated in the vacuum ultraviolet (VUV) region. 16 references.
Lupus pernio of the nose is the most characteristic cutaneous lesion of sarcoidosis. It is cosmetically disfiguring and can be the cause of significant morbidity. In particular, the affected skin is often red or purple due to increased vasculature. It is particularly resistant to both surgical and medical therapy. We describe a patient with lupus pernio affecting her nose, which showed a dramatic improvement following treatment with the pulse dye laser (PDL). A biopsy taken after treatment showed the continued presence of sarcoidal granulomas. We therefore feel that treatment with the PDL is an effective tool in improving the cosmetic appearance of lupus pernio, but does not influence the underlying disease process. PMID:11360426
Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.
Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed
Processing techniques utilizing low temperature depositions and pulsed lasers allow the fabrication of polysilicon thin film transistors (TFT`s) on plastic substrates. By limiting the silicon, SiO2, and aluminum deposition temperatures to 100(degrees)C, and by using pulsed laser crystallization and doping of the silicon, we have demonstrated functioning polysilicon TFT`s fabricated on polyester substrates with channel mobilities of up to 7.5 cm2/V-sec and Ion/Ioff current ratios of up to 1x10(to the 6th power).
The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).
We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.
The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.
The grain boundary crystallographic misorientations of magnetic-pulse-welded (MPW) aluminum alloy (AA) 6061-T6 in linear and tubular configurations were examined using the electron backscattered diffraction (EBSD) technique. A refined structure of heavily deformed grains with higher grain boundary angles was observed in linear welds. Significant spalling was observed away from the joints, in the interior of tubular welds. The results show the complex interaction of shock waves with the materials during this impact welding process.
Ascochyta blight causes significant yield loss in pulse crops worldwide. Integrated disease management is essential to take advantage of cultivars with partial resistance to this disease. The most effective practices, established by decades of research, use a combination of disease-free seed, destruction or avoidance of inoculum sources, manipulation of sowing dates, seed and foliar fungicides, and cultivars with improved resistance. An understanding of the pathosystems and the inter-relationship between host, pathogen and the environment is essential to be able to make correct decisions for disease control without compromising the agronomic or economic ideal. For individual pathosystems, some components of the integrated management principles may need to be given greater consideration tha...
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
Two hypotheses are in the centre of this investigation, on the one hand the question, whether microwaves as exogenous fields alone are able to stimulate human muscle cells above-threshold, and on the other hand, whether microwaves as conditioning to cathodical electrical pulses can modify the excitation threshold and form. No excitation through the application of microwaves alone can be introduced at any subject. The conditioning of above-threshold cathodical electrical pulses with UMTS-microwaves leads not to a transgression of the threshold or the electrical muscle response (EMG) depending on the amplitude, the duration or the dose rate. (orig.)
Experiments are described on a plasma cathode with biased grids to prevent entry of ions into the electron extraction gap. The cathode has potential applications to the generation of high-current pulsed electron beams. Operation at 20 A/cm"2 is theoretically possible. The source combines the low average power consumption of a plasma cathode with many of the attractive features of thermionic cathodes, such as space-charge-limited extractor gap electron flow, fast turn-on, and no diode closure. Initial experiments are reported at the 2 A/cm"2 level for pulse lengths to 160 #mu#s.
Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.
In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.
We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.
Conduction-band electrons, formed by pulse radiolysis of Degussa P25 TiO_2 particles, have been monitored by time-resolved microwave conductivity and found to undergo equilibrium localization and eventual recombination at the particle surface. In the presence of isopropyl alcohol recombination is retarded due to surface hole scavenging. The particle bulk can then be pumped with mobile electrons, which survive for seconds.
A new method is described for the analysis of high precision pulse annealing data obtained using IRSL measurements on potassium feldspars using a Risoe reader. Presenting the data as the percentage of the signal lost per annealing phase permits more detailed comparisons to be made between samples. In addition, it is possible to directly compare the temperatures at which the TL and IRSL signals are released, thus giving information about the relationship between them. This method of analysis is applied to pulse annealing data for natural, irradiated, preheated and IR bleached aliquots. (author).
BackgroundVisual acuity, the ability of the visual system to distinguish two separate objects at a given angular distance, is influenced by the optical and neuronal properties of...Full Text Available
A method is described for determining the particulate contamination in miniature ball bearings in which the bearing is flushed with a solvent that is then filtered. The particles that are collected on the filter are examined by optical microscopy.
Polycrystalline ZnO doped with Mn (5 and 10at%) was prepared by the co-precipitation method. The effect of Mn doping on the photocatalytic, antibacterial activities and the influence of doping concentration on structural, optical properties of nanoparticles were studied. Structural and optical properties of the particles elucidated that the Mn2+ ions have substituted the Zn2+ ions without changing the Wurtzite structure of ZnO. The optical spectra showed a blue shift in the absorbance spectrum with increasing dopant concentration. The photocatalytic activities of ZnO powders were evaluated by measuring the degradation of methylene blue (MB) in water under the UV region. It was found that undoped ZnO bleaches MB much faster than manganese doped ZnO upon its exposure to the U...
The structural, electronic and optical properties of ZnX and CdX (X = Se, Te and S) are studied using density functional theory by the Wien2k package. The energy band gap, real and imaginary parts of the dielectric function, energy loss function, optical absorption coefficient and reflectivity spectra of these compounds are calculated. The Engel-Vosko approach improves the energy band gaps of ZnX and CdX compounds. The calculated optical parameters are in good agreement with available experimental results, particularly in the Engel-Vosko approach. Furthermore the effect of hydrostatic pressure on the energy band gap, the real and imaginary parts of the dielectric function of these compounds is studied. The first and second order pressure coefficient for the energy band gaps, the static dielectric function and the static reflectivity spectra are calculated.
A major goal in optomechanics is to observe and control quantum behavior in a system consisting of a mechanical resonator coupled to an optical cavity. Work towards this goal has focused on increasing the strength of the coupling between the mechanical and optical degrees of freedom; however, the form of this coupling is crucial in determining which phenomena can be observed in such a system. Here we demonstrate that avoided crossings in the spectrum of an optical cavity containing a flexible dielectric membrane allow us to realize several different forms of the optomechanical coupling. These include cavity detunings that are (to lowest order) linear, quadratic, or quartic in the membrane's displacement, and a cavity finesse that is linear in (or independent of) the membrane's displacement. All these couplings are realized in a single device with extremely low optical loss and can be tuned over a wide ...
The operating principle is examined for an optical sensor for the angle of rotation of the drag ODUP-1 developed and manufactured by the VNII-1. Basic technical data are presented for the experimental model.
The inverse problem of interpreting the SS 433 optical light curves is solved for a geometrically thick model accretion disk around the compact relativistic object: most likely a black hole.
drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
... Secondly, the electrode- tissue interface may have ... stimulation of the optic nerve in a ... Ocular Electronic Vision Prosthesis, Australasian Ophthalmic ...
There is a mismatch between the documentation of the visually guided behaviors and visual physiology of decapods (Malacostraca, Crustacea) and knowledge about the neural architecture of their...Full Text Available
A new technique to monitor light diffraction patterns electrically is applied to frog semitendinosus muscle fibers at various levels of stretch. The intensity of the diffraction lines, sarcomere length...Full Text Available
In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic temperature sensing based on the technique of surface plasmon resonance (SPR). The metals considered for the present analysis are silver, gold and aluminium. The analysis is derived mainly from the thermo-optic effect along with some fundamental concepts of metal optics such as surface scattering, phonon-electron scattering and electron-electron scattering. The performance of the sensor with three different bimetallic nanoparticle alloy combinations is evaluated and compared, numerically, in terms of its sensitivity and accuracy. On the basis of the comparison and some logistic criterion, we predict the best possible bimetallic alloy combination along with a requisite alloy composition ratio that simultaneously provides higher values of both sensitivity and accuracy which is not possible with ...
effect of central star evolution would be to produce a thinner boundary, but the results of ... indicate that central star evolution may be neglected when ...
and Watkins,. W.B.: Further. Development of the Dynamic. Gas Temperature. Measurement ...... Grover, ed.,. SPIE. Proc. Vol. 954, Society of Photo-Optical ...
INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...
Light Weight Composite Mirrors for Science Instruments. Composite Optics, Inc. San Diego, CA. INNOVATION. Light weight, large aperture reflectors of graphite ...
We investigate the possibility of implementing a given projection measurement using linear optics and arbitrarily fast feedforward based on the continuous detection of photons. In particular, we systematically derive the so-called Dolinar scheme that achieves the minimum-error discrimination of binary coherent states. Moreover, we show that the Dolinar-type approach can also be applied to projection measurements in the regime of photonic-qubit signals. Our results demonstrate that for implementing a projection measurement with linear optics, in principle, unit success probability may be approached even without the use of expensive entangled auxiliary states, as they are needed in all known (near-)deterministic linear-optics proposals.
Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.
An innovative hybrid powder prepared using computer simulation allowed development of a new foundation having a fine, smooth texture that has never been achieved before. The optical structure/design of the powder was based on the results of measurements and analyses conducted on the optical characteristics of a baby's delicate skin, which is the envy of many women. To obtain the optimal optical characteristics, the finite differential time domain (FDTD) method for solving Maxwell's differential equation by difference and time domain was applied to the computer simulation method. For synthesis of the hybrid powder based on the optical model, a proprietary shape regulation coating technology was used in which flaky substrates were coated with microspherical forms of barium sulfate crystals. ...
switch when this cavity matching condition is determined. This results is a ... MHz offset is provided by an acousto-optic modulator. (AOM). The AOM will be shut ...
Cambridge scientists in the late 1980's. This same team, then headed by Professor John Baldwin, built the world's first separated-element optical/infrared aperture synthesis...
... Mineral and Organic Matter in the Coastal and Near-Coastal Ocean. ... Personal Author(s) : Stavn, Robert H. ; Spiering, Bruce A. ; Gould, Richard W ...
... reliability of fiber optics in preference over space-based systems. ... STC web site at www.aiaa.org/tc ... and improve lethalities of US weapon systems 3 ...
Dy doped #alpha#-SiAlON ceramics prepared by the hot-pressing method show a high optical transmittance value, >70%, in the infrared region of 1.5-4.5 #mu#m. First principles calculations have been carried out to reveal the underlying transparency mechanism. It is found that the valence shell of doped Dy atoms interacts strongly with the doping states of #alpha#-SiAlON, resulting in the increase in the optical gap from 0.4 to 1.1 eV, which suppresses the photoabsorption in the wavelength region longer than 1.0 #mu#m and leads to the good transparency property. The calculated optical transmission spectra are in good agreement with the corresponding experiments.
Ruthenium(II) and Iridium(III) polypyridyl complexes have been intensively investigated due to their use in energy conversion and light-emitting devices and materials for non-linear optics. Quantum mechanical computer simulations of molecules and materials have become increasingly popular in the scientific community. Along with experimental investigations, such computational analyses can provide complementary information on the electronic and optical properties of transition metal compounds of interest for optoelectronic applications. Here, we provide a unified review of recent work carried out on computational investigations of a large series of Ruthenium(II) and Iridium(III) polypyridyl complexes, discussing the relations between their electronic structure and optical properties and thei...
From the COMBO-17 digital sky survey data, 1,231 faint blue galaxies with photometric redshifts of 0.1optical data and by using both optical and near-infrared data. The results indicate that there are 183 galaxies whose photometric redshifts derived from both optical and infrared data are greater than 1.2, that the rms error of the derived photometric redshifts is 0.046, and that to increase the photometric SNR is also helpful for discriminating those misjudged low-redshift galaxies by using only the optical data. We have studied a...
The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to ...
Biosorption of uranium by residual biomass from The Old Bushmill`s Distillery Co. Ltd., Bushmills, Co. Antrim, Northern Ireland, following exposure to short and intense electric pulses has been examined. The biomass was prepared from the distillery spent wash and consisted of non-viable yeast and bacterial cells. As shown previously, untreated biomass had a maximum biosorption capacity of 170 mg uranium/g dry weight biomass. When biosorption reactions were placed between two electrodes and exposed to electric pulses with field strengths ranging from 1.25-3.25 kV/cm at a capacitance of 25 {mu}F, biosorption increased from 170 mg of uranium to 275 mg uranium/g dry weight biomass. The data were obtained from biosorption isotherm analyses and taken as the degree of biosorption at residual uranium concentrations of 3 mM. In addition, when the capacitance of the electric pulses increased from 0.25 {mu}F to 25 {mu}F at a fixed ...
Activation dose rates have been computed for the Poloidal Divertor Experiment Tokamak at the Princeton Plasma Physics Laboratory. Dose rates were computed in one-dimensional (cylindrical) geometry using the ANISN S/sub n/ transport theory code and the DKR radioactivity code. The EPR (DLC37F) 121-group coupled neutron-gamma cross section library was used with ANISN. For DKR, the 46-group neutron library of DCDLIB was employed. Dose rates were calculated for 1 minute, 1 hour, 6 hours, 24 hours, 1 week, and 1 month following a single pulse yielding 10/sup 15/ neutrons and for 2 hypothetical pulsing sequences. First, it was assumed that 10 pulses were conducted each day (1 hour apart) for 5 days. Second, it was assumed that 100 pulses were conducted each day (6 minutes apart) for 5 days. It was found that /sup 56/Mn and /sup 64/Cu are the main contributors to the dose at short time periods after shutdown, ...
The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of ...
Previous in vitro studies have demonstrated that Ho:YLF laser is capable of inducing physical and chemical changes on dental surfaces treated for caries prevention. The temperature in the pulp chamber was in vitro evaluated to as a function of the power and frequency of the laser irradiation. The purpose of this work is to verify the occurrence of pulp inflammation after Ho:YLF laser irradiation using different parameters in rabbits' teeth. The premolars and molars of ten rabbits (NZB) were divided in two groups according to the irradiation energy values of a Ho:YLF laser prototype operating at 2.065{mu}m wave length, frequency of O,5Hz and pulse length of 250{mu}s. An group A teeth were irradiated with using ten pulses of 334mJ/pulse of a Ho:YLF laser prototype operating at O.5Hz, and group B, with 512mJ/pulse. Animals were killed by transcardiac perfusion and the samples were prepared for ...
The paper discusses recent results on the development of localized arc filament plasma actuators and their use in controlling high-speed and high Reynolds number jet flows. Multiple plasma actuators (up to 8) are controlled using a custom-built 8-channel high-voltage pulsed plasma generator. The plasma generator independently controls pulse repetition rate (0-200 kHz), duty cycle and phase for each individual actuator. Current and voltage measurements demonstrated the power consumption of each actuator to be quite low (20 W at 20% duty cycle). Emission spectroscopy temperature measurements in the pulsed arc filament showed rapid temperature increase over the first 10-20 ?s of arc operation, from below 1000 deg. C to up to about 2000 deg. C. At longer discharge pulse durations, 20-100 ?s, the plasma temperature levels off at approximately 2000 deg. C. Modelling calculations using an unsteady, ...
A new optics providing an emittance close to the minimum theoretical value has been proposed for the Super-ACO storage ring with a reduced value of the momentum compaction factor and non-zero dispersive function in the Free-Electron Laser (FEL) section. It has been adapted to the FEL operation mode, with two RF cavities at 100 and 500 MHz. The obtained results concerning this new optics and the FEL oscillation are presented.
Correlations of the Woods-Saxon four-parameter optical potential of scattering of 38 MeV #alpha# particles on sup(68)Zn have been analyzed. A search for discrete sets of potential parameters and functional ratios between different parameters is carried out.
Refractive indices of some mixed compound semiconductors below the bandgap are presented on the basis of some fundamental parameters and the effect of lattice mismatch on the refractive index step is also studied. The results help to design a variety of opto-electronic devices for the use in optical fiber communication and heterostructure lasers. The calculated values agree well with available experimental values thus justifying the approach. (author).
A solar unit is described which contains a cavity radiation receiver, parabolic-cylindrical concentrator, and reflector arranged between the radiation receiver and the concentrator symmetrically in relation to the optical plane of the latter. In order to expand the range of use, it contains a pair of flat mirrors with 2 working surfaces installed at an angle and symmetrically to the optical plane of the parabolic cylindrical concentrator between them and the reflector, while the latter is made in the form of 2 flat mirrors installed at an angle on the cavity radiation receiver.
We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.
The polarization characteristics of spontaneous radiation from relativistic electrons moving through helical and planar wiggler fields are evaluated for imperfect beam injection. Maximum coherent gain in free-electron laser systems are seen to occur in optical fields having these polarization characteristics rather than those of the wiggler magnets. Coupling coefficients for an electron beam skewed at an angle to the optical mode are presented.
The optical properties of uranium monochalcogenides and monopnictides are discussed in terms of their electronic structure. A comparison is made with corresponding rare earth compounds. It is shown that there are close similarities to mixed valence CeN. the results support the occurrence of a dip in the density of d states near Esub(F), where the f density of states has its maximum. Empirical energy level schemes are derived which are found to agree with the existing information from XPS measurements and recent theories. (orig.).
Optical absorption measurements show that substitutional H"- ions, that is, protons with two electrons on anion sites, are thermally more stable than anion vacancies when thermochemically reduced CaO crystals are annealed in a reducing atmosphere. The H"- ions are identified by the infrared vibrational modes observed at 880 and 911 cm"-"1.
We show that the size of a lanthanide-ion doped nanoparticle can be accurately determined from its luminosity. The optically determined size distribution is in very good agreement with the distribution obtained from transmission electron microscopy. These data confirm that single nanoparticles are visualized in microscopy experiments. Nanoparticles as small as 13 nm are detectable with integration times of 500 ms.
PurposeOptic nerve aplasia (ONA, OMIM 165550) is a very rare unilateral or bilateral condition that leads to blindness in the affected eye, and is usually associated with other ocular...Full Text Available
A new magnetic electron microscope, UEMB-100, was designed with an increased electron-optical parameter. The electron-optical system consists of an electron canon (the high voltage is supplied by armored lead) and condensed, objective, intermediate, and projection lenses. In contrast to other native apparatuses, the microscope has a high resolving property (up to 20A) snnd great universality. (tr-auth)
We describe a liquid hydrogen droplet as an optical cavity via whispering gallery modes. We show that the droplet leads to an ultrahigh-cavity-Q value of 2.5x10{sup 9} in visible region. We show also that the high-Q droplet results in a huge Raman nonlinearity, generating a stimulated Raman comb series covering whole visible region.
Materials with high electrical conductivity and optical transparency are needed for future flat panel display, solar energy, and other opto-electronic technologies. InxCd1-xO...Full Text Available
We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the $^1S_0\\leftrightarrow^3P_0$ transition has been determined through comparisons with optical and microwave standards at NIST. The weighted mean of the evaluations is $\
Biofuels will have more intense impact on the energetic grid of the planet, because known fossil fuels reserves are being exhausted. The biofuel production relies on the transformation process of some organic material in the desired hydrocarbon product. Because of the natural characteristics of the related processes, fibre optic sensors appear to be adequate candidates to be used.
Visible laser light output from an electrically injected vertical cavity surface emitting laser (VSCEL) diode is enabled by the addition of phase-matching spacer layers on either side of the active region to form the optical cavity. The spacer layers comprise InAlP which act as charge carrier confinement means. Distributed Bragg reflector layers are formed on either side of the optical cavity to act as mirrors. 5 figs.
The application of differential optical absorption (DOA) techniques for the in-situ determination of the chemical composition of coal gasification process streams is investigated. Absorption spectra of relevant molecular species and the temperature and pressure effects on DOA-determined spectral characteristics of these species will be determined and cataloged. A system will be configured, assembled, and tested.
A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.
This report deals with the selection of a data communication system for a remote metering system. It covers the following three types of systems: fiber optic, telephone line, and radio packet. It provides a methodology for selecting a communication system for a given remote metering system and a method for comparing costs.
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
This work deals with a time-resolved optical study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen. The authors present the results obtained for nitrogen, from experiments and two-dimensional model simulations. This model is used to obtain a better insight in the relevant mechanisms and processes by a comparison of measurements and simulation data. The trends of externally measured quantities correspond with those predicted by the model.