WorldWideScience
2

Numerical calculation of the transient response of transmission systems using the natural spline functions, with applications on high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

To determine the transient response of linear and time-invariant transmission systems which are only described for discret frequencies, it is possible to find a good functional approximation by means of the generalized impulse method, combined with the most important natural spline-interpolation functions of the first and the third degree. This procedure has been applied to calculate the step response of the transient behaviour of the zero-sequence impedance system of the high voltage transmission line.

1981-10-01

3

Probability of backflashover in transmission lines due to lightning strokes using Monte-Carlo simulation  

Energy Technology Data Exchange (ETDEWEB)

A method, which estimates the lightning performance of high voltage transmission lines based on the Monte-Carlo simulation technique, is described in this paper. The average number of faults which occur in a transmission line, dividing them in single-phase and three-phase faults, as well as the average grounding resistances of the transmission lines are calculated. The method is applied, on several operating Greek transmission lines, showing good correlation between predicted and field observation results. The proposed method can be used as a useful tool in the design of electric power systems, aiding in the right insulation dimensioning of a transmission line.(author)

2003-02-01

4

Peculiarities of operation modes of 1200 kV AC long-distance transmission lines and some results of field tests thereon  

Energy Technology Data Exchange (ETDEWEB)

Since 1985 the operating sections of the 1200 kV AC Ekibastuz-Urals transmission system were used for a variety of field studies on a wide range of technological problems associated to high voltage transmission lines. The tests performed confirmed correctness of the main engineering and design decision made at development stage and demonstrated that such transmission lines are reliable and efficient. 3 figs.

1989-12-31

5

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

6

Southern receiver system: Environmental impact assessment status report: Conawapa to Winnipeg Power Transmission Complex  

Energy Technology Data Exchange (ETDEWEB)

The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.

1992-01-01

7

Combined heuristic with fuzzy system to transmission system expansion planning  

Energy Technology Data Exchange (ETDEWEB)

A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

2011-01-15

8

NAME=\\  

Wastenet

...Systems, UWA investigating rate uplift effects of shallow foundation systems associated with high voltage transmission line support towers. This work was funded by National Grid, ...

9

Electronics in mining symposium  

Energy Technology Data Exchange (ETDEWEB)

The symposium reviewed the use of electronics in mining today. Subjects covered include control systems; remote sensing; telemetry; data transmission; microprocessors and transportation systems. 15 papers have been abstracted separately.

1984-01-01

10

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine ...

2006-01-03

11

Calculation of the transmission capacity of long-distance EHV single-core submarine cable systems  

Energy Technology Data Exchange (ETDEWEB)

A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into ...

1981-11-01

12

Silicone-rubber washers soothe vibrating transmission lines  

Science.gov (United States)

Silicone-rubber washers function as damping and articulating elements in cast-aluminum spacers that separate bundle subconductors in each phase of extra-high-voltage transmission lines. Spacer/dampers are located every 3 ft. along transmission lines on Canada's first operational 500 and 735 kV system.

1965-01-01

13

Measurement of audible noise from transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.

1981-03-01

14

Need and specifications for a data transmission system for the mining industry  

Energy Technology Data Exchange (ETDEWEB)

The demands made on data transmission systems by modern mining companies are used to show why the currently used multiplexers cannot satisfy future requirement. The telecommunications department of Bergbau-Forschung GmbH is now developing a telecommunication system for underground work. The requirements made on this system are reported.

1980-02-01

15

Contribution to the compensation of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

An improved method to design suitable compensating schemes for extra high voltage transmission lines is presented. The technique is general and effective and will greatly facilitate the design of the optimal compensation scheme for extra high voltage transmission lines. The technique is illustrated for a typical 500 kV system. The equations developed here for voltage maxima and minima along the transmission line eliminate the need for point-to-point computation of the voltage profile. The controversy existing in the literature over the problem of making a choice between pi and tee configurations has been removed and it is established with a mathematical proof that the tee configuration requires compensating elements of lower ratings.

1987-04-01

16

Powertrain and apparatus using a continuously variable ratio transmission to improve fuel economy  

Energy Technology Data Exchange (ETDEWEB)

An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation ...

1981-07-28

17

Newer molecules in the treatment of schizophrenia: A clinical update  

UK PubMed Central (United Kingdom)

Schizophrenia is a heterogeneous psychiatric disorder in which multiple neurotransmitter systems have been implicated. Increased and decreased dopamine transmission in the subcortical meso-limbic and...Full Text Available

2011-04-01

18

Evidence from 12 geographically disparate power grids - NASA  

Science.gov (United States)

miles of high-voltage transmission lines with 12 intercon- nections to electricity systems in New York and Canada. As of 1 March 2003, ISO New England has ...

19

Single-pole switching schemes for EHV transmission systems  

Energy Technology Data Exchange (ETDEWEB)

Recognizing that a high percentage of transmission-line faults are single-phase to earth and temporary in nature, provides the impetus for considering single-pole switching as a means to enhance the reliability of EHV transmission systems. The effectiveness of single-pole switching schemes is largely determined by the speed with which the secondary arcs extinguish, and hence allow system restoration. Simulation techniques that enable better prediction of the faulted-system response are of obvious importance to the design and assessment of the various single-pole switching scheme applications. In this thesis, digital methods are developed to enable the faulted response of EHV systems to be simulated for a variety of different single-pole switching schemes. These include conventional single-pole switching, the hybrid method of autoreclosure, the neutral switched ...

1986-01-01

20

Induction effects of a 765 kV transmission line on a center pivot irrigator  

Energy Technology Data Exchange (ETDEWEB)

The use of irrigation systems in the proximity of high voltage transmission lines is increasing. This study examines the induced voltages and currents on a pivotal irrigation system operating under a 765 kV line. With a few simple precautions such as a system can be operated in complete safety. 1 ref.

1981-01-01

21

Project considerations and design of systems for wheeling cogenerated power  

Energy Technology Data Exchange (ETDEWEB)

Wheeling electric power, the transmission of electricity not owned by an electric utility over its transmission lines, is a term not generally recognized outside the electric utility industry. Investigation of the term`s origin is intriguing. For centuries, wheel has been used to describe an entire machine, not just individual wheels within a machine. Thus we have waterwheel, spinning wheel, potter`s wheel and, for an automobile, wheels. Wheel as a verb connotes transmission or modification of forces and motion in machinery. With the advent of an understanding of electricity, use of the word wheel was extended to be transmission of electric power as well as mechanical power. Today, use of the term wheeling electric power is restricted to utility transmission of power that it doesn`t own. Cogeneration refers to simultaneous production of electric and thermal power from an energy ...

1994-08-01

22

Accounting-related transmission issues  

Energy Technology Data Exchange (ETDEWEB)

Various initiatives have been undertaken by the Federal Energy Regulatory Commission (FERC) to deregulate wholesale electric energy markets. These initiatives have focused on restructuring the transmission systems in the US and recently have culminated in a proposal requiring formation of and participation in regional transmission organizations. The overall form of regulation selected to determine rates for transmission entities as well as underlying regulatory decisions reached on key issues will have profound implications for transmission entities. For example, traditional cost-based regulation would require one set of accounting and reporting rules, while incentive-based regulation may not be subject to those same rules. An overview of some of the major accounting and financial reporting issues that will need to be considered is presented.

1999-12-01

23

Proceedings of the Areva Technical Days. Session 5  

Energy Technology Data Exchange (ETDEWEB)

This document presents the proceedings of the Areva technical days, presented during the session 5 the 9 and 10 december 2004, at Istanbul. It deals with the operations of the transmission and distribution division. With manufacturing facilities in over 40 countries and a sales network in over 100, Areva offers customers technological solutions for nuclear power generation and electricity transmission and distribution (the Group also provides interconnect systems to the telecommunications, computer and automotive markets). It provides five topics: a general presentation of Areva, the strategic stakes for transmission and distribution by world-zone, economic and strategic stakes of business unit products, business unit systems and business unit automation. (A.L.B.)

2004-07-01

24

Application of activity on node network technique to monitor progress of transmission works in Himachal Pradesh  

Energy Technology Data Exchange (ETDEWEB)

Construction of high voltage transmission lines in a difficult hilly terrain within the limited time frame calls for the adoption of modern management tools for controlling the progress. The activity on node network system for such works, in which parallel and overlapping activities are involved is highly useful and is being used in Himachal Pradesh State Electricity Board. This network system has helped the Board to provide an effective and efficient mode of progress reporting at all levels of functioning. A remarkable example is the control of construction of 190 km - 200 kV dc transmission line within four years and six months.

1987-02-01

25

Electric loading of power transmission lines - statistical methodology and real time management; Carregamento eletrico de linhas de transmissao - metodologia estatistica e gerenciamento em tempo real  

Energy Technology Data Exchange (ETDEWEB)

This paper shows a computerized system, that adopt a statistical methodology and simultaneous measurements of wind velocity and environment temperature, as an experiences at the power transmission lines with environmental monitoring systems. 9 figs., 16 refs.

1991-12-31

26

The integration of renewable energy sources into electric power transmission systems  

Energy Technology Data Exchange (ETDEWEB)

Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmission lines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable sources can be integrated into existing ...

1995-07-01

27

Underground electric-power transmission-system environmental impact assessment  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy, Division of Electric Energy Systems, has undertaken to identify the environmental issues and potential impacts associated with the installation of underground electric power transmission systems. This study reports the results of investigations into the advanced cable technologies being considered for future underground applications, as part of the development oriented research program of the Division of Electric Energy Systems. While the technology involves a high level of sophistication, there are relatively few impacts to the environment that are potentially significant, and of these none are inherently non-mitigable. Route planning, system design, and methods of construction and accident response can be pursued in order to minimize impacts where strict constraints are appropriate.

1982-03-01

28

Maximum entropy probability method applied to assess voltage sag frequency due to transmission line fault in the electric power system  

British Library Electronic Table of Contents (United Kingdom)

Abstract Voltage sag caused by faults on an electric power transmission line is one of the most intractable power quality issues for both utility companies and customers. The fault in power system randomly exists along transmission lines due to the combination of many uncertain factors. To predict and assess the annual expected sag frequency (ESF) deriving from the faults along lines, a stochastic based method that employs maximum entropy principle, namely the maximum entropy probability method (MEPM), has been introduced in this paper. Moreover, various types of faults have been considered systematically. With the fault line intervals and the sample moments taken into account, the discrete values of distribution probability of fault locations along the transmission lines have been estimat...

2010-01-01

29

Curecanti-Blue Mesa-Salida 115-kV transmission lines access roads rehabilitation, maintenance, and construction project. Environmental Assessment  

Science.gov (United States)

Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.

1993-07-01

30

A multi-objective framework for dynamic transmission expansion planning in competitive electricity market  

Energy Technology Data Exchange (ETDEWEB)

Restructuring of power system has changed the traditional planning objectives and introduced challenges in the field of Transmission Expansion Planning (TEP). Due to these changes, new approaches and criteria are needed for transmission planning in deregulated environment. Therefore, in this paper, a dynamic expansion methodology is presented using a multi-objective optimization framework. Investment cost, congestion cost and reliability are considered in the optimization as three objectives. To overcome the difficulties in solving the non-convex and mixed integer nature of the optimization problems, a Non-Dominated Sorting Genetic Algorithm (NSGA II) approach is used followed by a fuzzy decision making analysis to obtain the final optimal solution. The planning methodology has been demonstrated on the IEEE 24-bus test system and north-east of Iran national 400 kV transmission grid ...

2010-10-15

31

Electricity transmission congestion costs: A review of recent reports  

Energy Technology Data Exchange (ETDEWEB)

Recently, independent system operators (ISOs) and others have published reports on the costs of transmission congestion. The magnitude of congestion costs cited in these reports has contributed to the national discussion on the current state of U.S. electricity transmission system and whether it provides an adequate platform for competition in wholesale electricity markets. This report reviews reports of congestion costs and begins to assess their implications for the current national discussion on the importance of the U.S. electricity transmission system for enabling competitive wholesale electricity markets. As a guiding principle, we posit that a more robust electricity system could reduce congestion costs; and thereby, (1) facilitate more vibrant and fair competition in wholesale electricity markets, and (2) enable consumers to seek out ...

2003-10-01

32

Multiple stress aging of solid-dielectric extruded dry-cured insulation systems for power transmission cables  

Energy Technology Data Exchange (ETDEWEB)

A detailed examination of the aging processes that may take place in solid-dielectric extruded-type high voltage transmission cables under dry conditions is presented. Particular emphasis is placed on the aging process as affected by the separate and simultaneous action of four main aging factors, namely the electrical, mechanical and thermal stresses, and the physical and chemical environment. A number of pertinent aging models are considered and their validity and applicability to accelerated aging tests on solid-type transmission cables are discussed.

1994-01-01

33

Accuracy of LLP system and lightning frequency map evaluated from transmission line faults; Rakurai ichi hyotei system no seido to rakurai hindo map no sodensen torippu jiko ni motozuku hyoka  

Energy Technology Data Exchange (ETDEWEB)

Accuracy of an LLP system and a lightning frequency map is evaluated by using transmission line faults in Hokuriku area from November in 1993 to October in 1996. The accuracy and efficiency of the system were calculated by statistical methods. From the above results, the lightning frequency map with 10 minutes meshes was proved capable of replacing the Isokeraunic Level Map with 15 minutes meshes used now for lightning protection design. However, the correlation between the number of detected lightning flashes and transmission line faults in each mesh was found to be week. This result suggests that more detailed analysis taking account of the length of transmission lines in each mesh is necessary. The correlation is stronger in winter than in summer, despite the fact that there is difference in the lightning current distribution in each mesh in winter. This characteristic can be ...

1997-10-20

34

System protection considerations related to single pole tripping of high-voltage transmission lines  

Science.gov (United States)

Single and selective pole tripping schemes may be used to maintain a desired level of system integrity while minimizing transmission line expenditures. In general, these schemes will be most effective on those portions of the system where relatively few interconnections exist. While selective pole tripping may superficially appear to provide more margin than single pole schemes in the preservation of system stability, it seems unlikely that in those actual applications where single pole tripping is warranted that selective pole tripping will provide any significant advantages.

1975-01-01

35

Trade curtailment schemes for the security control of the transmission network in a deregulated environment  

Energy Technology Data Exchange (ETDEWEB)

Due to deregulation, the electrical power industry is undergoing deep changes, moving towards an open market. Two kinds of parties are active in the new environment: the economical agents (producers, consumers, brokers) and the power system operator, the former interested in power exchanges and their economic value, the latter in bus injections and their threat to the security of the transmission network. The variables used to model the transmission network operation have to be meaningful to the power system operator as well as to the economical parties; the action rules followed by the power system operator to enforce network security have to be carefully designed to be equitable and non-discriminatory. In this paper, a modeling of the power exchanges is proposed in the form of multilateral trades, and some rules for the action of the power system operator are ...

2002-01-01

36

High voltage transmission lines studies with the use of artificial intelligence  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an ...

2009-12-15

37

Elk distribution and spatial overlap with livestock during the brucellosis transmission risk period  

British Library Electronic Table of Contents (United Kingdom)

Summary 1.-The presence of Brucella abortus within free-ranging wildlife populations is an important conservation and management issue because of the risk of brucellosis transmission between wildlife and livestock. Predicting wildlife distributions is necessary to forecast wildlife and livestock spatial overlap and the potential for brucellosis transmission. 2.-We used Global Positioning System data collected from telemetry-collared female elk Cervus elaphus to develop resource selection function (RSF) models during the brucellosis transmission risk period (the abortion and calving periods). We validated extrapolation of predictive models at two nearby elk ranges within the Greater Yellowstone Ecosystem. Additionally, we integrated extrapolated RSF maps and domestic livestock distributions...

2011-01-01

38

A novel wavelet transform aided neural network based transmission line fault analysis method  

Energy Technology Data Exchange (ETDEWEB)

In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmission line faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at different locations along the transmission line and an attempt has been made to correctly identify and locate the fault. ...

2009-06-15

39

Optimization of Hellenic overhead high-voltage transmission lines lightning protection  

Energy Technology Data Exchange (ETDEWEB)

It is well known that the lightning protection of transmission lines is exclusively relying on their correct initial design. Although detailed engineering studies are usually performed by electric power utilities for the design of new transmission lines, there are reported cases where the design is based simply on tradition or on utilities' standardization policy. In this paper, the lightning protection of high-voltage transmission lines is faced as an optimization problem where optimum design parameters are calculated for the lines, relating their cost with the lightning failures' cost, aiming to reduce or even eliminate lightning failures. The optimization method considers all the available protection means, i.e. ground wires and surge arresters. In order to validate the effectiveness of the proposed method, it is applied on several operating Hellenic transmission lines of 150 kV ...

2009-04-15

40

New concept in transmission line reclosure using high-frequency fault transients  

Energy Technology Data Exchange (ETDEWEB)

The authors present a new concept: 'adaptive optimal reclosure' under transmission line faults by integrating the adaptive and optimal reclosure techniques. Simulation studies prove that the proposed technique is able to first detect the persistence time of fault path arc and then capture the optimal reclosure time, thereby enhancing system stability. (author)

1997-07-01

41

Modeling dependent failures for the availability of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the calculation of availability for parallel transmission lines (two or more) in the same tower or on the same right of way. As in many studies, the development of mathematical models is an important step. The models are justified using historical data and known characteristics of power system elements. A statistical method was used to generalize the failure rate and repair rate from real operating data. Application of the new model (which combines common-mode, simultaneous independent, and dependent outages) is discussed.

1989-06-01

42

Highlights of technical support to the Department of Energy, Division of Electric Energy Systems, Electric Power and Transmission Programs. Final technical report, 1980-1981  

Energy Technology Data Exchange (ETDEWEB)

A broad-based, multidisciplinary research program is being conducted to study biological effects of electric and magnetic fields from high-voltage transmission lines. Assistance and technical support for this program are reported. (DLC)

1982-02-01

43

Electricity supply in the United Kingdom. Brief details and statistics  

Energy Technology Data Exchange (ETDEWEB)

Statistical detail is given of the electricity generation and transmission systems in the UK. Breakdown by type of station, by fuel and the proportion generated by others apart from the generating or area boards is presented. Figures are provided for the various high voltage transmission lines in terms of route and circuit length as well as the number of towers and the capacity of mains transformers.

1987-06-01

44

Prospective application of advanced series compensation to improve transmission system performance  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.

1994-12-31

45

Assessing the profitability of reactive power compensation devices  

Energy Technology Data Exchange (ETDEWEB)

A probabilistic method for assessing the profitability of reactive power compensation devices such as capacitors, static VAR compensators and generators, which improve network security, was described. Since network development is limited by environmental constraints, power networks are operated close to their limits. Because of this fact transmission network planning increasingly relies on techno-economic models to improve network security and profitability. The proposed method consists of analyzing large numbers of constrained power system states, extracted from power system simulation exercises. The paper describes details of the method and provides an example of a numerical application on a part of the French power transmission system. 10 refs., 8 figs.

1997-12-31

46

Validity of the CT to attenuation coefficient map conversion methods  

International Nuclear Information System (INIS)

The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.

2004-04-27

47

A Reduced Wind Power Grid Model for Research and Education  

Energy Technology Data Exchange (ETDEWEB)

A reduced grid model of a transmission system with a number of central power plants, consumption centers, local wind turbines and a large offshore wind farm is developed and implemented in the simulation tool PowerFactory (DIgSILENT). The reduced grid model is given by Energinet.dk, Transmission System Operator of Denmark (TSO) for Natural Gas and Electricity, to the Danish Universities and the Risoe National Laboratory. Its intended usage is education and studying of interaction between electricity-producing wind turbines and a realistic transmission system. Focus in these studies is on voltage stability issues and on the ride-through capability of different wind turbine concepts, equipped with advanced controllers, developed by the Risoe National Laboratory.

2006-07-01

48

An optimal design method for improving the lightning performance of overhead high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a method for the optimal design of high voltage transmission lines taking into consideration shielding and backflashover failure rates. The minimization of suitably defined performance indices, which relate the failures caused by lightning in a transmission line to both line insulation level and tower footing resistance, is aimed. Optimum values for both line insulation level and tower footing resistance are calculated. The method is applied on several operating Hellenic transmission lines of 150 and 400kV, respectively, carefully selected among others, due to their high failure rates during lightning thunderstorms. Special attention has been paid on open loop lines, where a possible failure could bring the system out of service causing significant problems. The obtained design parameters, which reduce the failure rates caused by lightning, are compared with the existing design ...

2006-04-15

49

System control and data acquisition of the two new FWCD RF systems at DIII-D  

Energy Technology Data Exchange (ETDEWEB)

The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and ...

1995-10-01

50

In vitro selection of RNA molecules that displace cocaine from the membrane-bound nicotinic acetylcholine receptor  

UK PubMed Central (United Kingdom)

The nicotinic acetylcholine receptor (AChR) controls signal transmission between cells in the nervous system. Abused drugs such as cocaine inhibit this receptor. Transient kinetic investigations indicate...Full Text Available

1998-11-24

51

Conawapa to Winnipeg Power Transmission Complex. Southern Receiver System: Environmental impact assessment status report  

International Nuclear Information System (INIS)

Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmission lines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations ...

1992-01-01

52

Dynamics of HVDC system under unbalanced AC transmission line faults and its stabilization. Koryukei fuheiko kosho ni taisuru chokuryu keito no odo tokusei to anteika seigyo  

Energy Technology Data Exchange (ETDEWEB)

The application of HVDC system to the trunk power supply system requires the transmission of DC power as much as possible to improve the stability of the whole AC/DC system. To meet this requirement, continued pulse system, which keeps sending a DC current even when an AC voltage lowers remarkably, has been used. The stability is much more improved by adding damping control which modulates converter active and/or reactive power. In order to make full use of such control effects, it is important that the HVDC system maintains stable operation during faults and reclosing of the AC system. In particular, it is necessary to prevent a repetitive commutation failure following the unbalanced AC transmission line faults. In this paper, the cause of the repetitive commutation failure is discussed by using the AC-DC power ...

1992-01-20

53

DYMAC communications system  

Energy Technology Data Exchange (ETDEWEB)

The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system ...

1980-01-01

54

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the ...

1993-03-01

55

Needs for Constructing and Possibilities of Nuclear Power Plants Interconnection to the Croatian Electricity Grid  

International Nuclear Information System (INIS)

Due to development of electric power system and considering an increase of electrical energy consumption, needs for larger units in new power plants are obvious. Connection of large nuclear power plants to the grid, depending on their power and location, usually requires significant investments in transmission network development and construction. Considering the capacity of the 400 kV transmission network in Croatia, this problem is evident. This paper deals with the possibilities of nuclear power plants construction, as one possible option in electric power system development, and their interconnection to the electricity grid. (author).

1998-06-15

56

Electrical equipment of the Marchtrenk power station on the river Traun  

Energy Technology Data Exchange (ETDEWEB)

By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.

1982-03-01

57

Power system stabilizer application in a two unit plant analytical studies and field tests  

Energy Technology Data Exchange (ETDEWEB)

The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the alternator rectifier ...

1983-02-01

58

Pricing of constraints - the England & Wales experience  

Energy Technology Data Exchange (ETDEWEB)

The existence, in real-time, of transmission constraints, demand forecasting errors, generator failures, and other factors impose additional costs through the need to run more expensive generation. These costs can appear as a significant component of the wholesale price to demand served by electricity markets operated over transmission networks. In the England & Wales Pool these costs are passed through directly to supply companies. The Transmission System Operator ({open_quotes}TSO{close_quotes}) can exert significant influence on these costs through improved availability of transmission circuits and through appropriate investment, but has no incentive to do so. Since the inception of the Pool, these costs have increased in level and volatility, and have proved difficult to hedge. In response, St Clements Services were instrumental in assisting Pool members to develop an ...

1996-03-01

59

Lightning performance assessment of Hellenic high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A methodology for assessing the lightning performance of Hellenic high voltage transmission lines has been developed. Its main advantage is that the analysed transmission line is divided into regions and the analysis is conducted separately for each one region, taking into account the individual characteristics, which exist in each one of them. The developed approach intends to offer more accuracy in the assessment of lightning performance of Hellenic high voltage transmission lines and of similar lines, where they run at the same time through a plain region, a coastline and/or a mountainous region. The aims of the paper are to describe in detail the proposed methodology and to present results obtained by its application on operating Hellenic transmission lines of 150 and 400 kV. The computed results are compared with the results produced by another software tool published in the technical literature ...

2008-04-15

60

Analysis of lightning fault detection, location and protection on short and long transmission lines using Real Time Digital Simulation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmission lines, more specifically in the 500 kV transmission lines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmission lines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are presented not only with the times of lightning faults elimination, but also all the ...

2007-07-01

61

Shared-memory performance of multiple computer terminals in parallel distributed information-processing systems  

Energy Technology Data Exchange (ETDEWEB)

A system model for transmission of computer user's data with a finite number of regular users in a resource-sharing mode in parallel distributed information-processing systems is considered. The mini/microcomputer included in the system model is considered to be receiving the mixed arrival data of the user from a picture-phone terminal with uniformly-distributed data arrivals and a teletypewriter terminal with Erlang-distributed data arrivals. The large-memory performance of the mini/microcomputer is analysed with the mixed input data, constant service-times, synchronous transmission and single server interruption through a first-order Markov process. A simple and general approach to calculate the data arrivals from picture-phone and teletypewriter terminals and their mixed data arrivals is presented. Expressions for memory content probability and average queueing delay are ...

1984-03-01

62

Proceedings, international symposium on mine mechanization and automation  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under the session headings: research in mechanical fragmentation; rock characterization, remote sensing and interface detection; monitoring, data transmission and communications; tunnel boring machines; minewide monitoring and expert systems for ground control; machine guidance; shaft and raise boring; automation of drilling equipment; machine automation and control; new developments in mechanical miners; materials handling; innovative mining systems; general minewide monitoring and expert systems; ground support; human factors; and extraterrestrial mining.

1991-01-01

63

High-temperature superconductivity (HTS): summary of case study results; Vorteile der Hochtemperatursupraleitung. Resultate von Fallstudie  

Energy Technology Data Exchange (ETDEWEB)

The system study 'High Temperature Superconductivity (HTS) in power systems' lists the technical and economical advantages for power generation, transmission and distribution systems using components made of HTS material as seen in the light of current knowledge in the superconductivity area. This report lists the advantages of using high-temperature superconductivity in the power industry area and summarises the results obtained in various case studies on the subject.

2000-07-01

64

Evaluation of routine telephone transmission of nuclear medicine studies  

Energy Technology Data Exchange (ETDEWEB)

Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.

1989-01-01

65

A novel wavelet transform aided neural network based transmission line fault analysis method  

British Library Electronic Table of Contents (United Kingdom)

In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmission line faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at differ...

2009-01-01

66

Integrated evolutionary neural network approach with distributed computing for congestion management  

British Library Electronic Table of Contents (United Kingdom)

Electric supply industry is facing deregulation all over the world. Under deregulated power supply scenario, power transmission congestion has become more intensified and recurrent, as compared to conventional regulated power system. Congestion may lead to violation of voltage or transmission capacity limits, thus threatens the power system security and reliability. Also the growing congestion may lead to unanticipated divergent electricity pricing. Owing to these facts congestion management has become a crucial issue in the deregulated power system scenario. Fast and precise prediction of nodal congestion prices in real time deregulated/spot power market may enable market participants and system operators to keep pace with the congestion by taking preventive measures like transaction resc...

2010-01-01

67

Development of a through-the-earth monitor system. Open file report (final) Oct 77-Dec 80  

Energy Technology Data Exchange (ETDEWEB)

The object of this program was to design and build a self-contained system for remote monitoring of the atmosphere in mines. The system developed uses the mine pager phone line as the primary communication channel and also has the capability of using 208 Hz in the ELF band for wireless transmission through the earth. The depth for through-the-earth transmission is expected to be about 80 to 90 meters in high conductivity soil and is limited by the noise level in the ELF band-pass filters. The underground components of the TEM System are energized by mine power through a battery charger-storage battery power supply. In the event of mine power failure the battery capacity is more than sufficient for 1 week's operation with interrogations every 4 hours.

1980-12-01

68

Leak detection on petroleum pipelines  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.

1984-04-01

69

HPOF transmission-system economic-evaluation program. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.

1983-01-01

70

Controlled serial compensator for load control and excess-current release. Geregelter Serienkompensator fuer Lastflussregelung und Ueberstrombegrenzung  

Energy Technology Data Exchange (ETDEWEB)

With the compensator-series equipment put into operation in 1992 - giving a performance of 330 Mvar - it was made possible for high-performance electronics to use a continuously variable, fully loaded power transmission line and to regulate the energy flow and minimise overcurrent losses. As well as these technical qualities, this system could offer environmental advantages for European implementation. This would avoid the need to plan and construct new high voltage transmission lines in order to meet increased demand. (orig.)

1994-06-01

71

5 GHz 200 Mbit/s radio over polymer fibre link with envelope detection at 650 nm wavelength  

DEFF Research Database (Denmark)

All-optical envelope detection of a 5 GHz 200 Mbit/s modulated radio frequency signal is achieved using a 650 nm resonant cavity light emitting diode. Error-free transmission is achieved over a 50 m-long link of 1 mm diameter graded index polymer optical fibre (POF). The presented system has potential applications in low cost and low complexity short range wireless and wireline POF-based transmission links.

2008-01-01

72

The development of a centralized automatic monitoring system for coal mines: composition and functions of the system  

Energy Technology Data Exchange (ETDEWEB)

A centralized, automatic monitoring system for coal mines has been developed. The system consists of newly-developed and improved sensors, transmission equipment, a minicomputer designed for scientific and technical calculations, and accompanying software (MOLES). MOLES performs six functions: input, computation, decision, memory, output and correction. Previously, centralized monitoring has been limited to single dimensional monitoring of the 'time and point' type. The present system carries out data analysis and processing with respect to time, space and item. It is also capable of simple automatic diagnosis of abnormalities. (In Japanese)

1983-01-01

73

Small and medium load supply - an approach to Brazilian central and north region  

Energy Technology Data Exchange (ETDEWEB)

Small electrical demand supply systems, to serve small communities close to high voltage transmission lines, have been examined to delineate their technical and economic characteristics. Parameters to measure system performance were outlined. Development of the Brazilian version of the Energy Overhead Ground Wires (EOHGW) system was described. This system has been supplying electricity to Rondonia and Mato Grosso states in central and northern Brazil, Operating experiences with this system were reviewed. 4 refs., 8 tabs.

1996-12-31

74

Broadband Local Area Network security monitoring--Magnovox CATV Systems Inc. Digital System Sentry product evaluation  

Energy Technology Data Exchange (ETDEWEB)

Use of a broadband Local Area Network (LAN) for transmission of classified and secure unclassified information requires monitoring capabilities which are sensitive to discrete segments of the network frequency spectrum. A viable monitoring system must be capable of detecting possible intrusion attempts or network malfunctions and alerting operating and security personnel. This report documents the results of an evaluation of the Magnavox CATV Systems Inc. Digital System Sentry software for network monitoring. Recommendations are made on its possible future role in broadband LAN security monitoring throughout the Nuclear Weapons Complex.

1991-01-01

75

Particle Swarm Optimization Based Reactive Power Optimization  

CERN Document Server

Reactive power plays an important role in supporting the real power transfer by maintaining voltage stability and system reliability. It is a critical element for a transmission operator to ensure the reliability of an electric system while minimizing the cost associated with it. The traditional objectives of reactive power dispatch are focused on the technical side of reactive support such as minimization of transmission losses. Reactive power cost compensation to a generator is based on the incurred cost of its reactive power contribution less the cost of its obligation to support the active power delivery. In this paper an efficient Particle Swarm Optimization (PSO) based reactive power optimization approach is presented. The optimal reactive power dispatch problem is a nonlinear optimization problem with several constraints. The objective of the proposed PSO is to minimize the total support cost ...

2010-01-01

76

Evaluation of improvements in the installation of rural underground transmission lines: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.

1987-10-01

77

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral ...

2011-05-05

78

Packet Drop Avoidance for High-speed network transmission protocol  

Energy Technology Data Exchange (ETDEWEB)

As network bandwidth continues to grow and longer paths are used to exchange large scientific data between storage systems and GRID computation, it has become increasingly obvious that there is a need to deploy a packet drop avoidance mechanism into network transmission protocols. Current end-to-end congestion avoidance mechanisms used in Transmission Control Protocol (TCP) have worked well on low bandwidth delay product networks, but with newer high-bandwidth delay networks they have shown to be inefficient and prone to unstable. This is largely due to increased network bandwidth coupled with changes in internet traffic patterns. These changes come from a variety of new network applications that are being developed to take advantage of the increased network bandwidth. This paper will examine the end-to-end congestion avoidance mechanism and perform a step-by-step analysis of its theory. In addition we will propose an ...

2004-05-01

79

Living and Working Safely Around High-Voltage Power Lines.  

Energy Technology Data Exchange (ETDEWEB)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

2001-06-01

80

Development of a new technology for preparing samples for transmission electron microscopy (TEM) on the basis of ion fine beam processing; Entwicklung einer neuen Technologie zur Probenpraeparation fuer die Transmissions-Elektronenmikroskopie (TEM) auf der Basis der Ionenfeinstrahlbearbeitung  

Energy Technology Data Exchange (ETDEWEB)

The goal of this project was to develop a new technology for preparing samples for transmission electron microscopy (TEM) on the basis of ion fine beam processing. For this purpose processes of ion-beam-assisted removal (sputtering), separation, sample handling and ion-beam-assisted chemical etching as well of system-inherent components were examined. As an alternative to a Ga-source a liquid-metal ion source based on a AuGeSi alloy was developed, characterised and used in the FIB 4400. [German] Aufgabe des Projektes war die Entwicklung einer neuen Technologie zur Probenpraeparation fuer die Transmissions-Elektronenmikroskopie (TEM) auf der Basis der Ionenfeinstrahlbearbeitung. Dazu wurden Prozesse der ionenstrahlgestuetzten Abtragung (Sputtern), der Abscheidung, des Probenhandling, des ionenstrahlgestuetzten chemischen Aetzens sowie systemeigener Komponenten untersucht. Als Alternative zur Ga-Quelle wurde eine ...

2001-08-01

81

Application of artificial neural network methods for the lightning performance evaluation of Hellenic high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Feed-forward (FF) artificial neural networks (ANN) and radial basis function (RBF) ANN methods were addressed for evaluating the lightning performance of high voltage transmission lines. Several structures, learning algorithms and transfer functions were tested in order to produce a model with the best generalizing ability. Actual input and output data, collected from operating Hellenic high voltage transmission lines, as well as simulated output data were used in the training, validation and testing process. The aims of the paper are to describe in detail and compare the proposed FF and RBF ANN models, to state their advantages and disadvantages and to present results obtained by their application on operating Hellenic transmission lines of 150kV and 400kV. The ANN results are also compared with results obtained using conventional methods and real records of outage rate showing a quite satisfactory agreement. The proposed ...

2007-01-15

82

Analysis of algorithms for ultra high speed relays for the protection of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British ...

1984-01-01

83

An artificial neural network for directional comparison relaying of transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Distance protection, differential protection and directional comparison schemes are presently used for protecting transmission lines. Directional comparison relays are set to respond to faults in the protection zone without intentional time delay and are, therefore, used where high-speed fault clearing is needed. Artificial Neural Networks (ANNs) can handle most situations which cannot be defined sufficiently for finding a deterministic solution. The design and testing of an ANN for directional comparison protection of transmission lines are presented in this paper. Training patterns were generated using voltage and current samples for faults at various locations along a transmission line. The faults were simulated using an electromagnetic transient program and a sample three-phase power system. The performance of the proposed discriminator was checked using data simulated for testing and the fault data ...

1997-12-31

84

Upgrading the ampacity of HPFF pipe-type cable circuits  

Energy Technology Data Exchange (ETDEWEB)

The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.

1994-12-31

85

Testing modern protective relays  

Energy Technology Data Exchange (ETDEWEB)

Modern microprocessor-based relays for the protection of the various power system components such as generators, transformers, feeders, and high voltage transmission lines are becoming more sophisticated as increasingly more complex functions and capabilities can be included in the microprocessor. With this increasing complexity, and the increasing complexity of the power system itself, there is even more value in testing the suitability of relaying equipment for the intended applications. This paper reviews the testing philosophy, experience, and capabilities developed at Ontario Hydro over more than 25 years of testing protective relays.

1994-01-01

86

Satellite power systems (SPS) concept definition study (Exhibit D). Solid-state amplifier investigation. Final report  

Energy Technology Data Exchange (ETDEWEB)

Data resulting from a continuing effort to provide system/subsystem definition data to aid in the evaluation of the SPS program concept is presented. The specific data described relate to the proposed use of solid state devices as microwave power amplifiers in the satellite microwave power transmission subsystem.

1981-04-01

87

New advances in mitigating environmental impact of pipe-type cables  

Energy Technology Data Exchange (ETDEWEB)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

1999-04-01

88

Environmentally inoffensive electric drive for the VW Golf  

Energy Technology Data Exchange (ETDEWEB)

Electric cars run silently and produce no exhaust fumes. In cooperation with other companies BBC has developed a compact drive system for the VW Golf comprising a battery-powered separately excited DC motor, transmission, control system and setpoint devices. With a range of 57 km and a top speed of 90 km/h, the electric Golf lends itself well to city driving.

1981-01-01

89

A New DC Breaker Used as Metallic Return Transfer Breaker.  

Energy Technology Data Exchange (ETDEWEB)

When a bipolar HVDC transmission system is operating monopolar using the earth as a return path, it is often desired to divert the return current from the earth to the line from the unused pole. To do so requires either that the system be shut down temporarily or that a dc circuit breaker be used. This paper describes the development of such a new dc circuit breaker, and its application on the Pacific Intertie as a Metallic Return Transfer Breaker (MRTB).

1982-10-01

90

Improvement of power system stability by high speed power control of adjustable speed machine; Kahensokuki no koshutsuryoku seigyo ni yoru denryoku keito no anteido kojo  

Energy Technology Data Exchange (ETDEWEB)

Large capacity adjustable speed machines (ASMs) at pumped storage power station have been put into full operation and the operating characteristics of ASM have been highly evaluated from the view point of power system operation. The output power (input power) of ASM can be controlled very quickly by applying a vector control scheme to the excitation control. This quick responsive feature of ASM can make it possible to improve the stability of the neighbor sub-power system. For improvement of transient stability, the output power of ASM is reduced very quickly in order to control the acceleration of neighbor generators during and after transmission line faults. For improvement of dynamic stability, the output power of ASM is modulated in accordance with the stabilizing signals detected from the swing of generator rotor or the power flow fluctuation on the transmission line. This paper describes the ...

1997-01-20

91

The European energy market and environmental considerations: Options for Norwegian industry  

Energy Technology Data Exchange (ETDEWEB)

The power industry is undergoing major changes. Deregulation and a competitive climate demand effective solutions. Costs and losses must be reduced, and overall efficiency must be raised. Industrial options connected to energy market and environmental considerations are discussed. Themes discussed in this paper are environmental challenges, the fuel factor, power plants in use today, the Norwegian power system, the European system, power exchange across borders, the transmission system, the future European system, and options for Norwegian industry. 27 figs.

1995-12-31

92

Simplified RF power system for Wideroe-type linacs  

Energy Technology Data Exchange (ETDEWEB)

The RF system for the SuperHILAC injector linac was designed and constructed for minimum system complexity, wide dynamic range, and ease of maintenance. The final amplifier is close coupled to the linac and operates in an efficient semilinear mode, eliminating troublesome transmission lines, modulators, and high level regulators. The system has been operated at over 250 kW, 23 MHz with good regulation. The low level RF electronics are contained in a single chassis adjacent to the RF control computer, which monitors all important operating parameters. A unique 360/sup 0/ phase and amplitude modular is used for precise control and regulation of the accelerating voltage.

1981-03-01

93

The market potential for SMES in electric utility applications. Final report  

Energy Technology Data Exchange (ETDEWEB)

Superconducting magnetic energy storage (SMES) is an emerging technology with features that are potentially attractive in electric utility applications. This study evaluates the potential for SMES technology in the generation, transmission, distribution, and use of electric energy; the time frame of the assessment is through the year 2030. Comparisons are made with other technology options, including both commercially available and advanced systems such as various peaking generation technologies, transmission stability improvement technologies, and power quality enhancement devices. The methodology used for this study focused on the needs of the market place, the capabilities of S and the characteristics of the competing technologies. There is widespread interest within utilities for the development of SMES technology, but there is no general consensus regarding the most attractive size. Considerable uncertainty exists ...

1994-06-01

94

Assessment of information impacts in power system security against malicious attacks in a general framework  

International Nuclear Information System (INIS)

In the analysis of power systems security, recently a new concern related to possible malicious attacks caught much attention. Coordination among different transmission system operators (TSO) in an interconnected power system to counteract such attacks has become an important problem. This paper presents a general framework for describing the physical, cyber and decision-making aspects of the problem and their interrelations; within this framework, an analytic tool for the assessment of information impacts in handling on-line security after a malicious attack is proposed and discussed. The model is based on the socially rational multi-agent systems and the equilibrium of a fictitious play is considered to analyze the impacts of various levels of information available to the interconnected system operators on the outcomes of the decision-making process under ...

2009-06-01

95

Adding channels with PSBT format at 40Gbit/s in an existing 10Gbit/s optical network  

British Library Electronic Table of Contents (United Kingdom)

Until recently, the wavelength-division-multiplexed (WDM) transmission system has reached record capacities and distances due to innovations such as FEC (Forward Error Correction), distributed Raman amplification, new transmission fiber and advanced optical format. Optical-communication systems exclusively employed conventional On-Off Keying signals in either Non-Return-To-Zero (NRZ) or Return-To-Zero (RZ) format. Recently a number of advanced modulation formats have attracted attention. Some of these formats carry information through On-Off-Keying but also modulate the optical phase in order to enhance the robustness of signal to chromatic dispersion, optical filtering and non-linearities. Through extensive sets of simulation results, we showed that it is possible to replace a channel wit...

2011-01-01

96

Impact of independent power producers in a deregulated system  

Energy Technology Data Exchange (ETDEWEB)

Independent power producers (IPPs) have had open access to existing power systems ever since the electric power industry was restructured and deregulated. IPPs are small-scale, distributed, and independently operated. Introducing an IPP to the power system can be beneficial to the existing power system because it can increase the security margin or reduce production cost and environmental pollution. The disadvantage is that some IPPs are not subject to dispatch control, consequently, they may reduce the network security. Often IPPs use co-generation, small-scale hydro, even fuel cells or other types of renewable energy sources. An evaluation of IPPs impact on an existing utility power system was determined in a modified IEEE 14 bus system. The total generating cost, environmental impact, transmission line margin, voltage profile, network congestion, security and ...

1997-04-01

97

Utility activities that create power quality problems  

Energy Technology Data Exchange (ETDEWEB)

Power quality problems are caused by activities normal to utility operations such as maintenance outages and capacitor switching or events that are abnormal such as lightning strikes and equipment failures. Disconnection and reconnection of transmission lines and transformers can cause switching surges, and are more severe on extra high voltage transmission lines than high voltage lines. Capacitor switching can cause transients and harmonics that may affect sensitive equipment, and are the source of 3rd, 5th, 7th and 9th harmonics in the hundreds of hertz ranges. Overload, sudden loss of generating capacity and transmission line faults are typical problems affecting system stability. Fault interruptions and reclosings can cause surges in the distribution system, and lightning strikes may cause voltage surges or dips due to arrester sparkover. Blackouts, brownouts, voltage ...

1992-02-01

98

Laboratory Evaluation of an Electrochemical Noise System for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines  

Energy Technology Data Exchange (ETDEWEB)

Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those ...

2003-03-16

99

Submarine 525 kV power transmission line for Vancouver island  

Energy Technology Data Exchange (ETDEWEB)

The studies undertaken by the B.C. Hydro company at the Canada showed that the existing system of hydroelectric power plants and transport cables will not be able to satisfy the increasing energy demand on the Vancouver island after 1985, and that the best solution will be the installation of a 525 kV transfer system from the continent. THe STK participated to the development and the immersion of this new system, the first in the world comprising submarine 525 kV transport parts. This paper presents the planning, the development, the submerging and the installation of two sections of submarine cable.

1985-01-01

100

Transient overvoltages and overcurrents during line fault tests on the Hokkaido-Honshu HVDC line  

Energy Technology Data Exchange (ETDEWEB)

A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmission line faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the ...

1982-08-01

101

Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV  

Energy Technology Data Exchange (ETDEWEB)

The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

1994-07-11

102

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

103

Revolutionary news on superconductivity  

Energy Technology Data Exchange (ETDEWEB)

A brief article gives an update on the commercial exploitation of superconductivity by the American Superconductor Corporation. Potential applications include transmission and distribution, motors, magnetic storage systems, current limiters and transport. The company have produced a kilometre long, ''wrappable'' cable capable of carrying thousands of amps when operating at a temperature of below -140[sup o]C. (UK)

1994-09-01

104

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

105

Program Status | Environmental Information Exchange Network & Grant Program | US EPA  

Wastenet

... Reduce partner costs, save time, and overcome delays in data transmission. Data Exchanges States are currently submitting data to each other and to the EPA in the exchanges listed below. Data Exchanges are typically referred to by their acronyms, which are listed below. To find out more about EPA data exchanges, please follow the links to EPA Web sites. AQS - Air Quality Sub-system (...

106

Plan-view transmission electron microscopy of crack tips in bulk materials  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system has been applied to prepare a thin foil specimen of Si, MgO and alumina which contained cracks in the plan of foil. It was possible to observe a much larger area at and near a crack tip than has been hitherto possible. FIB was also applied to observation of microstructure near a crack tip evolved during severe rolling contact fatigue in a steel.

1996-12-01

107

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

108

Leak location in fluid filled cables using the PFT method  

Energy Technology Data Exchange (ETDEWEB)

A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.

1999-01-01

109

High resolution transmission electron microscopy of a #beta#'-sialon-TiN nanocomposite  

International Nuclear Information System (INIS)

TEM and HRTEM have been used to characterise the microstructures of materials formed by hot-pressing silicon nitride with an Al_2O_3-SiO_2-TiO_2 densification aid system, to form #beta#'-sialon-TiN composites in which the TiN particles are of 20-100 nm dimension. (orig.).

1992-06-21

110

HVDC submarine cables for the Hokkaido Honshu linkage  

Energy Technology Data Exchange (ETDEWEB)

The direct-current submarine cable interconnecting Hokkaido and Honshu (hereafter called HH linkage) is an example of installation of an undersea cable for long-distance power transmission crossing a sea strait. In particular, the feature of this interconnection is that an oil-filled (OF) cable is used for the high-voltage side with crosslinked polyethylene (XPLE) cable adopted for the return to comprise a conductor return system. The details of the facilities, especially the design of the OF submarine cable are described. 3 refs.

1981-04-01

112

Corona effect in high voltage transmission lines; O efeito corona em linhas eletricas aereas de alta-tensao  

Energy Technology Data Exchange (ETDEWEB)

Corona from bare conductors of electrical overhead power lines is studied in this article. Its origin, as well as, its bad influences over communication systems are both studied, yet. Line`s models are defined, in order to be able the examination of Corona on line`s cables. Formulas for the surface electrical gradient calculations are shown. (author) 2 refs.

1993-12-01

113

Construction - laying and installation techniques for extruded and self contained fluid filled cable systems  

Energy Technology Data Exchange (ETDEWEB)

The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.

2001-07-01

114

A legal-historical consideration of links between Canadian and South African racial policies  

British Library Electronic Table of Contents (United Kingdom)

Significant recent writings have suggested strong parallels and actual links between the historical legal architectures of Canadian Aboriginal policy and South African apartheid. This article's further probing of these claims shows them to be very doubtful. At the same time, some more limited legal parallels between the two systems shows the importance of undertaking further analysis of the transmission and exchange of legal ideas and norms within the Commonwealth order.

2010-01-01

115

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

116

Fundamental aspects of fault location algorithms used in distance protection  

Energy Technology Data Exchange (ETDEWEB)

Considers fundamental problems involved in the precise location of faults on high-voltage transmission lines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmission line. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.

1986-09-01

117

Electrotransmission of high traffic capability. Elektroperedachi povyshennoi propusknoi sposobnosti  

Energy Technology Data Exchange (ETDEWEB)

Comparative indices are given for the efficiency of phase control of remote-controlled self-compensating high-voltage transmission lines, including a consideration of the power transfer effect between high-voltage line circuits. A description is given of certain circuit variations for performing the technical means of regulating phase shift, and their characteristics which make it possible to evaluate the effect of the phase regulators on the electrical transmission system are also given. An examination is made of problems concerned with the design of lines, relay protection, computation of transfer processes and dynamic stability as well as the computation of over-voltage when shutting off short circuits during amplified electromagnetic ties between line circuits.

1981-01-01

118

Detect and classify faults using neural nets  

Energy Technology Data Exchange (ETDEWEB)

The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.

1996-10-01

119

Seasonal characteristics of lightning channel and its relationship to transmission line faults; Kaminari hodenro no kisetsu tokusei to sodensen jiko no kankei  

Energy Technology Data Exchange (ETDEWEB)

In the Hokuriku area along the coast of the Japan Sea, thunderstorms often occurred not only in summer but also in winter, and this resulted in the shutdown of electricity supply or damage of equipment. This study was concerning the observation of the lightning channels in the Hokuriku area through a year by many still cameras equipped with liquid-crystal shutters. The following conclusions were obtained: Among 165 lightning incidents photographed during 2 years, there included 172 incidents of the falling thunderstorms and 23 incidents of simultaneously falling thunderstorms at multi-area. In the case of winter, frequency to occur simultaneously falling thunderstorms at multi-area was higher and the upward falling thunderstorms were more. There was a tendency that the duration time of the lightning current in winter was longer than in summer. In winter, frequency to occur the upward falling thunderstorms was higher, about 61% of the upward falling thunderstorms rose from the ...

1996-02-20

120

Synchronized sampling improves fault location  

Energy Technology Data Exchange (ETDEWEB)

Transmission line faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmission lines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmission line only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmission line ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several circumstances, such as varying switching and loading conditions, fault infeed from the ...

1995-04-01

121

Identification and characterization of populations living near high-voltage transmission lines: A pilot study  

Energy Technology Data Exchange (ETDEWEB)

Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 [mu]T, and sometimes over 2 [mu]T. Yet, populations studied in most epidemiologic investigations of the association between residential magnetic field exposure and cancer typically have exposures below 1 [mu]T and frequently below 0.5 [mu]T. To improve statistical power and precision, it would be useful to compare high exposure populations with low exposure population. Toward this end, we have developed an automated method for identifying populations living near high-voltage transmissions lines. These populations likely have more highly exposed individuals that the population at large. The method uses a geographic information system (GIS) to superimpose digitized transmission line locations on U.S. Census block location data and then extract relevant demographic data. Analysis of ...

1993-12-01

122

Assessment of audible noise from high voltage transmission lines and a high voltage transformer station  

Energy Technology Data Exchange (ETDEWEB)

The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have been identified and documented in a tape ...

1986-11-01

123

Performance of distance relays in a 150 kV grid in case of cross-country faults. Gedrag van distantiebeveiligingen in een 150 kV-net bij cross-country fouten  

Energy Technology Data Exchange (ETDEWEB)

In the 150 kV power system of the Dutch energy utility MEGA Limburg cross-country faults have caused problems in the protection of high voltage transmission lines. A cross-country fault is the simultaneous presence of two single-phase earth connections in different phases and places within the grid. These cross-country faults can lead to the incorrect operation of a number of distance relays, which could result in the faulty disconnection of high voltage transmission lines. To gain an insight into these problems, the transient phenomenon in the power system during cross-country faults were studied. For this purpose, the simulation program EMTP (ElectroMagnetic Transients Program) has been used. Simulation models of the 150 kV power system and the measuring system of a distance relay were developed within EMTP. 7 figs., 1 ill.

1994-11-01

124

Laboratory development of +- 600 kVdc pipe type cable systems  

Energy Technology Data Exchange (ETDEWEB)

In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe cable design was finally designated for ...

1982-07-01

125

Satellite power system (SPS) concept definition study (Exhibit D). Volume 2: systems/subsystems analyses. Final report  

Energy Technology Data Exchange (ETDEWEB)

Modifications to the reference concept were studied and the best approaches defined. The impact of the high efficiency multibandgap solar array on the reference concept design is considered. System trade studies for several solid state concepts, including the sandwich concept and a separate antenna/solar concept, are described. Two solid state concepts were selected and a design definition is presented for each. Magnetrons as an alternative to the reference klystrons for dc/rf conversion are evaluated. System definitions are presented for the preferred klystron and solid state concepts. Supporting systems are analyzed, with major analysis in the microwave, structures, and power distribution areas. Results of studies for thermal control, attitude control, stationkeeping, and details of a multibandgap solar cell study are included. Advanced laser concepts and the meteorological effects of a laser beam power ...

1981-01-01

126

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

127

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

128
129

Report on system operation - A background report prepared by the Nordel Operation Committee/OPG in the Nordel project on enhancing efficient functioning of the Nordic electricity market  

Energy Technology Data Exchange (ETDEWEB)

This report contains the operation procedures in extreme situations and lessons learned from blackouts, based on a mandate given by the Operations Committee. Nordic TSOs have had common rules and principles for system operation i.e. System Operation Agreement since the late 1990s. The rules have been revised according to the system security and market changes and needs. The collaboration between system operators is regular and fruitful. The knowledge and capability to manage extreme situations of the Nordic power system has continuously increased and the recent blackouts did not show major deficiencies in operation practices. Regardless of the existing good collaboration it is important to continue development in the future in order to ensure high system security. Important development areas are security of reserve supervision and coordination of calculation ...

2004-12-01

130

Request for an Analytical Transmission Electron Microscope.  

Science.gov (United States)

... Accession Number : ADA189111. Title : Request for an Analytical Transmission Electron Microscope. Descriptive Note : Final rept. ...

1987-10-16

131

A bright field scanning transmission electron microscope (STEM ...  

Science.gov (United States)

A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...

132

Optimal pole shifting controller for interconnected power system  

Energy Technology Data Exchange (ETDEWEB)

Research highlights: {yields} Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. {yields} Power system stabilizer was designed based on optimal pole shifting controller. {yields} The system performances was tested through load disturbances at different operating conditions. {yields} The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. {yields} The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is ...

2011-05-15

133

Optimal pole shifting controller for interconnected power system  

International Nuclear Information System (INIS)

Research highlights: ? Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. ? Power system stabilizer was designed based on optimal pole shifting controller. ? The system performances was tested through load disturbances at different operating conditions. ? The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. ? The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a ...

2011-05-01

134

Wind power data transmission challenges; Les defis de la transmission de donnees en eolien  

Energy Technology Data Exchange (ETDEWEB)

This presentation outlined the corporate history of the Ohmega Group, a small company from Gaspe, Quebec which offers consulting services to the automation and telecommunication sector. It was created in 1982 and has been involved with the wind power industry since 1996. The main services provided by Ohmega Group include electrical and mechanical construction and maintenance services. This paper also reviewed the benefits of using Supervisory Control and Data Acquisition (SCADA) systems in the wind power industry to monitor, control and collect data from wind turbines. The Ohmega Group has provided consulting services to Cartier Wind Energy Inc., a company that was awarded several wind turbine projects by Hydro-Quebec Distribution. The Ohmega Group applied the SCADA system at the Baie des Sables, Anse a Valleau and Carleton wind turbine arrays. The typical architecture of SCADA systems on a wind farm was presented along ...

2008-07-01

135

Unique approach to an old problem: New technology helps BC Hydro locate heat resistance  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro`s approach to improve the performance of its underground transmission lines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the cable line to within ...

1997-06-01

136

Ballard fuel cells and the changing energy landscape  

Energy Technology Data Exchange (ETDEWEB)

The numerous challenges facing the North American electric utility industry were discussed. In addition to competition, electric utilities are faced with low demand growth, public pressure to avoid adding transmission and distribution capacity, and strict environmental requirements. In view of these developments, large central generation additions that have been industry norm until recently, do not always make economic sense in the current environment. Instead, smaller, distributed additions to generating capacity is becoming the new norm. Small-scale on-site generating capacity has the added advantage of reducing the need for expensive high-voltage transmission lines. The Ballard generation system described here is a modular, efficient fuel cell-based solution to implementing distributed power concepts. The system is natural gas fueled, with low noise, vibration and emissions. Apart from its other ...

1997-02-01

137

Summary of research on microbiological processes. International Energy Agency Subtask D, final report  

Energy Technology Data Exchange (ETDEWEB)

Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES systems studied do not ...

1992-09-01

138

Summary of research on microbiological processes  

Energy Technology Data Exchange (ETDEWEB)

Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES systems studied do not ...

1992-09-01

139

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized ...

1983-11-01

140

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)

141

A microcontroller-based data-acquisition system for meteorological station monitoring  

International Nuclear Information System (INIS)

This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of ...

2008-12-01

142

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will ...

2007-10-29

143

Bridging SCADA islands: A solution for the distribution of information and commands among geographically separate control centers  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a gas transmission pipeline company with dissimilar local control and Supervisory Control and Data Acquisition (SCADA) systems that had formed over time, and the solution that was put into place to consolidate those systems. Great Lakes Gas Transmission Company (GLGT) had historically operated the pipeline from four geographically different locations with a combination of various local man-machine interface (MMI) control systems and an aging SCADA system. As new control systems were installed at compressor and meter stations, local and corporate data acquisition needs changed. It became apparent that the existing SCADA system which telemetered a minimal set of control data could no longer support growth requirements. The decision was made to replace the old SCADA system with a ...

1996-12-31

144

Multi-objective optimal generation scheduling considering operators' adaptability concept. Un prime yosha no manzokudo wo koryoshita hatsudenki shutsuryoku no tamokuteki saiteki haibun  

Energy Technology Data Exchange (ETDEWEB)

Demands for electric power system, which include not only minimization of generation cost but also protection of environmental condition and maintenance of transmission security, have been diversified The priority of these objectives may change according to load change, weather, and other conditions. Since these objectives are usually in a trade-off relationship and generally non-commensurable, it is difficult to handle by conventional optimization of a single objective function. This report describes multi-objective scheduling of thermal power system. The adaptability of three performance indicies, such as economic efficiency, NO{sub x} emission, and transmission security, to operators are defined by membership functions in fuzzy set theory. coordinated solution in which the adaptability of operators is maximized can be obtained by maximizing the fuzzy decision-making function composed of the ...

1992-01-20

145

Bonneville Power Administration, Office of Engineering 10-Year Plan, 1992-2001 : Draft.  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, the Bonneville Power Administration (BPA) has evolved to supply electric power to more than 170 customer utilities and direct service industries across 14,800 miles of high voltage transmission lines. BPA's Office of Engineering provides the planning, development, and engineering for the required expansion, upgrade, and replacement of the transmission system. The purpose of this 10-Year Plan is to present strategies to maintain a reliable energy delivery system within changing public, business, technological, and environmental climates. The issues and trends discussed in this document and our strategies for addressing them provide the background for the Office of Engineering programs and projects. With a budget in the hundreds of millions annually and increasing public concern, we welcome the opportunity to communicate with our customers. In addition to the factors, trends ...

1992-05-01

146

Bonneville Power Administration, Office of Engineering 10-Year Plan, 1992-2001 : Draft.  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, the Bonneville Power Administration (BPA) has evolved to supply electric power to more than 170 customer utilities and direct service industries across 14,800 miles of high voltage transmission lines. BPA`s Office of Engineering provides the planning, development, and engineering for the required expansion, upgrade, and replacement of the transmission system. The purpose of this 10-Year Plan is to present strategies to maintain a reliable energy delivery system within changing public, business, technological, and environmental climates. The issues and trends discussed in this document and our strategies for addressing them provide the background for the Office of Engineering programs and projects. With a budget in the hundreds of millions annually and increasing public concern, we welcome the opportunity to communicate with our customers. In addition to the factors, trends and issues ...

1992-05-01

147

HVDC submarine power cables systems state of the art and future developments  

Energy Technology Data Exchange (ETDEWEB)

The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, allowing a transmission of 500 MW each (i.e., 2 GW total). One of the peculiarities ...

1995-12-31

148

Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils  

Energy Technology Data Exchange (ETDEWEB)

An overview of BC Hydro`s review of its overhead transmission system to withstand earthquakes and its program of seismic upgrading, including the upgrading of tower pile foundations in liquefiable soils, was presented. BC Hydro`s system, geologic environment, seismic design criteria, investigations and analysis, treatment and alternatives and a case history of a seismic upgrade of a tall river crossing tower at the Pitt River in the Lower Mainland of B.C. were summarized. It was concluded that the inherent strength of towers, conductors, fittings and insulators was sufficient to withstand earthquakes. The towers most susceptible to slope and soil failure due to seismic activity were tall river crossing towers. It was suggested that soils investigations, seismicity, ground response, liquefaction and stability analyses be carried out at each site. The results of these tests would help to establish system ...

1995-12-31

149

STATUS OF THE DIELECTRIC WALL ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

2009-04-22

150

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

151

Ion-induced phase formation in metal-silicon systems  

International Nuclear Information System (INIS)

By using megaelectronvolt "4He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd_2Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni_2Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment. (Auth.).

152

How can natural gas markets be competitively organized  

International Nuclear Information System (INIS)

In this paper it will be discussed how to most effectively give room to competitive forces in natural gas markets, given the traditional merchant pipeline as point of departure. Alternative models of organizing the market will be reviewed: we first consider decreasing barriers to entry and then analyse advantages and drawbacks of a third party access system. In this context different forms of implementing a competitive market for transportation capacity and coordinating it with gas trade are discussed, among them a simultaneous auction of gas and transmission capacity. Finally a hub system of point markets will be suggested to improve the currently implemented third party access system and to allow for competitive markets for gas and transportation service. 33 refs., 6 figs.

153

Dynamic voltage control by remote voltage regulation for pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.

1988-08-01

154

An innovative method of providing total breaker failure protection  

Energy Technology Data Exchange (ETDEWEB)

Breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the utility`s breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting a circuit breaker from the failure described above, plus other failures that go unprotected with conventional schemes, this providing total ...

1996-09-01

155

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26

156

Smart Acquisition EELS  

Energy Technology Data Exchange (ETDEWEB)

Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.

2010-07-01

157

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

Energy Technology Data Exchange (ETDEWEB)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga{sup +} ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

158

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

International Nuclear Information System (INIS)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga"+ ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

159

Selected topics in transient response of aerial lines to high-altitude electromagnetic pulse  

International Nuclear Information System (INIS)

Aerial lines or cables, as one mainly energy transport path of electronic system when illuminated by HEMP, has been often modeled by field-to-transmission line model. However, in many cases, authors too often encounter some confusing statements to the lines effects during experimental procedure. The aim of this paper is to present and discuss these cases, such as the electromagnetic environment above the ground plane, the contribution of the different electromagnetic field component to the induced current and voltage, variations of the load current for different line heights and ground conductivities etc. (authors)

2005-11-01

160

Randomization of heavily damaged regions in annealed low energy Ge{sup +}-implanted (0 0 1)Si  

Energy Technology Data Exchange (ETDEWEB)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge{sup +}-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-15

161

Randomization of heavily damaged regions in annealed low energy Ge"+-implanted (0 0 1)Si  

International Nuclear Information System (INIS)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge"+-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-01

162

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

163

Integrated photonic qubit quantum computing on a superconducting chip  

International Nuclear Information System (INIS)

We study a quantum computing system using microwave photons in transmission line resonators on a superconducting chip as qubits. We show that linear optics and other controls necessary for quantum computing can be implemented by coupling to Josephson devices on the same chip. By taking advantage of the strong nonlinearities in Josephson junctions, photonic qubit interactions can be realized. We analyze the gate error rate to demonstrate that our scheme is realistic even for Josephson devices with limited decoherence times. As a conceptually innovative solution based on existing technologies, our scheme provides an integrated and scalable approach to the next key milestone for photonic qubit quantum computing.

2010-06-01

164

Damping of capacitance voltage substations ferroresonance using a suitable RLC filter  

Energy Technology Data Exchange (ETDEWEB)

The underlying theory and model of capacitive voltage substations and its associated problems are described. This system is intended to supply electricity to rural communities directly from high-voltage transmission lines. This technique leads to important cost reductions when compared with conventional alternatives. However, in several transient cases, some problems such as ferroresonance and overvoltages could occur in these substations. Using a developed capacitive substation model these transient cases are simulated. A suitable filter is designed to damp overvoltages clue to ferroresonance. Analytical aspects of filter design are presented and some computer simulation tests are provided to highlight the usefulness of the proposed filter. (author)

2004-11-01

165

Control device of a high voltage circuit breaker equipped with closing resistors  

Energy Technology Data Exchange (ETDEWEB)

A high voltage self-blowing circuit breaker with closing resistors is equipped with an auxiliary contact inserted in the trip control circuit of an electrical circuit breaker. The auxiliary contact is actuated by the mechanical control rod of the circuit breaker in such a way as to prevent any operator closing error. A high-speed mechanism is inserted in the link system connecting the control rod and the auxiliary contact, with dead travel to delay closing of the auxiliary contact when a closing operation takes place and to prevent a tripping order from being transmitted too early. Such an early transmission would be liable to cause a flashover on the inserter contacts and damage to the circuit breaker.

1991-02-12

166

Acoustic metamaterial exhibiting four different sign combinations of density and modulus  

CERN Document Server

We fabricated a double negative acoustic metamaterial which consisted of Helmholtz resonators and membranes. Experimental data on the transmission and dispersion relation are presented. The system exhibits three frequencies where the acoustic state makes sharp transitions from density negative ({\\rho} -NG) to double negative (DNG), modulus negative (B-NG), and double positive (DPS) in sequence with the frequency. We observed a wide range of negative refractive index from -0.06 to -3.7 relative to air, which will allow for new acoustic transformation techniques.

2011-01-01

167

A solution to add digital signatures to medical images according to the DICOM standard: embedded systems  

International Nuclear Information System (INIS)

Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)

2005-01-01

168

500-kV cable lines  

Energy Technology Data Exchange (ETDEWEB)

A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmission lines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.

1980-01-01

169

Evaluation of a Superconducting Fault Current Limiter Model for Electric Power System  

Science.gov (United States)

Fault current limiters (FCLs) are devices for to suppress current in electric power system. The FCL is extensively expected to suppress fault current, particularly required for trunk power systems heavily connected high-voltage transmission lines, such as 500 kV class power system. For this reason, FCLs based on various principles of operation have been developed. Most of the FCLs under development which employ superconductors are based on the quenching phenomenon peculiar to the superconducting state, that is, making use of a rapid transition to normal conducting state, an electrical resistance appears, and this resistance is used to suppress fault currents. However, this elevation of resistance, although increasing the fault current suppression effect, also tend to raise the overvoltage occurring FCL, the ascertainment of the overvoltage is important as regards the protection of the FCL as well as ...

2003-01-01

170

Dynamic Rating and Underground Monitoring System (DRUMS)  

Energy Technology Data Exchange (ETDEWEB)

Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical ...

1991-07-01

171

Effect of systemic blockade of ?(1)-noradrenergic receptors on sex behavior and vaginal-cervical stimulation-induced Fos in female rats.  

Science.gov (United States)

It is hypothesized that systemic ??-noradrenergic antagonists may interfere with the transmission of sensory stimulation, particularly vaginal--cervical stimulation (VCS), which is crucial for reproductive functioning. To determine if ??-noradrenergic transmission receptor activity is necessary for transmission of sensory information important for VCS-dependent events, we conducted an experiment using prazosin, a ??-noradrenergic receptor antagonist. First, three doses of prazosin (1.0, 0.5 or 0.1 mg/kg) or the 10% ETOH in sesame oil vehicle were administered i.p. and sexual receptivity was assessed 30 min later in ovariectomized, hormone-treated female rats. The 1 mg/kg dose of prazosin significantly inhibited lordosis quotients and lordosis ratings. This dose of prazosin (1.0 mg/kg) was then administered 30 min prior to VCS or control scapular stimulation (CSS) and Fos-IR was examined in the ...

2010-10-01

172

Fuzzy coordination of multi-objectives reflecting the operator's intention for dynamic generation rescheduling [of power systems  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a novel and efficient algorithm to obtain optimal generation dispatch reflecting the operator's intention in power system rescheduling. In optimal system operation, various objectives, such as economy, quality and transmission security, need to be achieved simultaneously. However, these objectives are often contradictory and in a trade-off relationship with respect to each other thus making it difficult to handle this class of problem by conventional approaches. In the proposed algorithm, optimal generation dispatch is formulated as a multi-objective optimization problem. A fuzzy coordination technique based on fuzzy set theory is used to obtain an optimal solution. Evaluation indices composed of fuel cost, transmission line overload and AFC regulation capacity margin are measured by the membership functions, and multi-objective optimization is solved by maximizing the ...

1992-10-01

173

Resistive cryogenic cable economic-viability evaluation. Final report, Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment ...

1980-03-31

174

MIMO (multi-input multi-output) adaptive power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A multivariate adaptive power system stabilizer is proposed. The advantages of using coordinated governor and excitation control are discussed, and the problems associated with constant parameter power system stabilizers (CPSS) are highlighted. The proposed multi-input multi-output (MIMO) power system stabilizer can coordinate the governor and excitation control and can overcome the problems associated with CPSS in power system stabilization. Selective multivariable state modelling, identification and control methods are investigated and the MIMO least squares technique with variable forgetting factor is used for system identification, guaranteeing good parameter tracking after a disturbance. Two multivariable self-tuning algorithms are investigated, the generalized minimum variance control and pole-shifting control algorithms. The multivariable self-searching pole-shifting ...

1988-01-01

175

EM-MWD technology; EM-MWD system jitsuyoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

A project on the title is a special study of TRC (Technology Research Center) Japan National Oil Corporation, which aims at developing a system collecting many data near well bottom while drilling. The project is a 3-year project from 1993 to 1995 succeeding to results of a project on real-time drilling control technology which was finished in fiscal 1992. This paper is a record in fiscal 1993. In 1993, the first year, TRC starts a joint study with relational enterprises aiming at utilizing an EM-MWD (electromagnetic-measurement while drilling) system practically. Based on the past fruit of the study, the EM-MWD system was applied to an highly inclined well or a horizontal well. A total system was constructed, which improved electromagnetic radiation transmission efficiency, and reliability, and workability. An electromagnetic radiation receiver system for an ...

1994-10-31

176

Development of a survey-design support sytem using soil data base; Doshitsu data base wo mochiita chosa sekkei shien system no kaihatsu ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as power plants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this system to the thermal power plant location program and to the ...

1994-09-05

177

Design of multifunction anti-terrorism robotic system based on police dog  

Science.gov (United States)

Aimed at some typical constraints of police dogs and robots used in the areas of reconnaissance and counterterrorism currently, the multifunction anti-terrorism robotic system based on police dog has been introduced. The system is made up of two parts: portable commanding device and police dog robotic system. The portable commanding device consists of power supply module, microprocessor module, LCD display module, wireless data receiving and dispatching module and commanding module, which implements the remote control to the police dogs and takes real time monitor to the video and images. The police dog robotic system consists of microprocessor module, micro video module, wireless data transmission module, power supply module and offence weapon module, which real time collects and transmits video and image data of the counter-terrorism sites, and gives military attack based on ...

2007-11-01

178

Scaling up prevention programmes to reduce the sexual transmission of HIV in China  

UK PubMed Central (United Kingdom)

Background Since 2007, sex has been the major mode of HIV transmission in China, accounting for 75% of new infections in 2009. Reducing sexual transmission is a major challenge for China...Full Text Available

2010-12-01

179

Relationship Between Exposure, Clinical Malaria, and Age in an Area of Changing Transmission Intensity  

UK PubMed Central (United Kingdom)

The relationship between malaria transmission intensity and clinical disease is important for predicting the outcome of control measures that reduce transmission. Comparisons of hospital data...Full Text Available

2008-08-01

180

Knowledge and behaviour of nurse/midwives in the prevention of vertical transmission of HIV in Owerri, Imo State, Nigeria: a cross-sectional study  

UK PubMed Central (United Kingdom)

BackgroundMother-to-Child Transmission (MTCT) of HIV remains the main mode of acquisition of HIV in children. Transmission of HIV may occur during pregnancy, delivery or breastfeeding....Full Text Available

181

On load flow control in electric power systems  

Energy Technology Data Exchange (ETDEWEB)

This dissertation deals with the control of active power flow, or load flow in electric power systems. During the last few years, interest in the possibilities to control the active power flows in transmission systems has increased significantly. There is a number of reasons for this, coming both from the application side - that is, from power system operations - and from the technological side. where advances in power electronics and related technologies have made new system components available. Load flow control is by nature a multi-input multi-output problem, since any change of load flow in one line will be complemented by changes in other lines. Strong cross-coupling between controllable components is to be expected, and the possibility of adverse interactions between these components cannot be rejected straightaway. Interactions with dynamic phenomena in the power ...

2000-01-01

182

Investigation of methods for improving models of ionospheric plasma-density irregularities and radio-frequency scintillation. Technical report  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.

1993-11-01

183

Interpolating atmospheric water vapor delay by incorporating terrain elevation information  

British Library Electronic Table of Contents (United Kingdom)

In radio signal-based observing systems, such as Global Positioning System (GPS) and Interferometric Synthetic Aperture Radar (InSAR), the water vapor in the atmosphere will cause delays during the signal transmission. Such delays vary significantly with terrain elevation. In the case when atmospheric delays are to be eliminated from the measured raw signals, spatial interpolators may be needed. By taking advantage of available terrain elevation information during spatial interpolation process, the accuracy of the atmospheric delay mapping can be considerably improved. This paper first reviews three elevation-dependent water vapor interpolation models, i.e., the Best Linear Unbiased Estimator in combination with the water vapor Height Scaling Model (BLUE?+?HSM), the Best Linear Unbiased Es...

2011-01-01

184

In situ strain measurements during the formation of palladium silicide films  

Energy Technology Data Exchange (ETDEWEB)

The evolution of strain in the Pd-Si system during the growth of Pd{sub 2}Si thin films on Si (100) substrate has been followed in situ using a double optical beam technique. As was observed for the Pt-Si system, the reaction to form Pd{sub 2}Si yields a compressive intrinsic surface film stress as well as for the silicon-rich suicides as proposed by Angilello et al. [Thin Film Interfaces and Interactions, edited by J. Baglin and J. Poate (The Electrochemical Society, Pennington, NJ, 1980)]. A transmission electron microscopy analysis has revealed grain growth during the formation of Pd{sub 2}Si which cannot account for the compressive film stresses. The formation of silicide at the interfaces rather than the overall change in volume agrees with the sign of the stresses formed. 29 refs., 4 figs., 3 tabs.

1993-03-01

185

Improved model of high-latitude F-region scintillation (WBMOD version 13). Final report, 1 September 1993-31 August 1994  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth`s ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can he used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the third year of this project, which includes completion of the new model for the high-latitude (auroral and polar cap) region of the WBMOD model.

1994-08-31

186

Genetic algorithm approach for the determination of the electrical parameters of railway traction lines  

British Library Electronic Table of Contents (United Kingdom)

The problem of electrical parameters identification in complex systems, and in particular in electric railway traction systems, is considered. Parameters are determined by an indirect approach: only the terminal variables (voltages and currents and, impedance and admittance, which can be readily calculated) are measured and the per-unit-length electrical parameters are determined using a multiconductor transmission line model of the track section under test. It will be shown that some parameters cannot be measured directly, that they are not constant with frequency and that they may depend on other external conditions. An indirect method for parameters identification is proposed through an adaptive algorithm (AA), so that the calculated terminal variables match the measured ones. The AA is...

2008-01-01

187

Field results using measurement-while-drilling directional systems in Long Beach, California  

Energy Technology Data Exchange (ETDEWEB)

One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.

1981-01-01

188

Dynamic construction of outage lists for safety analysis of power transmission lines. Dynamische Erstellung von Ausfallisten fuer die Sicherheitsanalyse elektrischer Energieuebertragungssysteme  

Energy Technology Data Exchange (ETDEWEB)

An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).

1990-04-23

189

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)

2002-03-01

190

Design of power system stabilizer through state variable feedback  

Energy Technology Data Exchange (ETDEWEB)

When the transmission line is very long or the generator is operated at a power factor nearly equal to 1.0, the machine regulated by an automatic voltage regulator (AVR) cannot be operated stably due to poor dynamic stability. To overcome this difficulty, the so called power system stabilizer (PSS) is very useful, in that output power or rotor speed of the generator is used as a feedback signal. The primary obective of the PSS is to damp the swing of the generator as quickly as possible. A method is proposed for designing PSS which yields a given eigenvalue. In the second method, the use of a Heffron-Phillips model is discussed. Next, a detailed procedure for the proposed design method is presented. A generalized method of a PSS design based on Park's equation and matrix operation is proposed.

1980-05-01

191

Analysis of even harmonics generation in an isolated electric power system  

British Library Electronic Table of Contents (United Kingdom)

Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmission line fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...

2009-01-01

192

An X-ray photoelectron spectroscopic study of B-N-Ti system  

International Nuclear Information System (INIS)

Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. in order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general interest.

1997-04-04

193

A trial of probabilistic simulation for reference case in the second progress report on research and development for the geological disposal of HLW in Japan  

International Nuclear Information System (INIS)

This paper presents a trial of probabilistic simulation for performance assessment of high-level waste (HLW) disposal using the Monte Carlo method. Based on the Reference Case conceptual model in H12, a new integrated simulation system which allowed us to rapidly evaluate the effect of data uncertainty was developed. The doses to hypothetical exposure group were compared with the results of H12 that were performed by using a point-wise approach, in terms of maximum total dose. This study showed that H12 results were consistent with results of probabilistic simulation and also showed that transmissivity had a strong influence for the uncertainty of the system performance in all simulation time. (author)

2000-12-01

194

A Generic Impact-Scoring System Applied to Alien Mammals in Europe  

British Library Electronic Table of Contents (United Kingdom)

Abstract: We present a generic scoring system that compares the impact of alien species among members of large taxonomic groups. This scoring can be used to identify the most harmful alien species so that conservation measures to ameliorate their negative effects can be prioritized. For all alien mammals in Europe, we assessed impact reports as completely as possible. Impact was classified as either environmental or economic. We subdivided each of these categories into five subcategories (environmental: impact through competition, predation, hybridization, transmission of disease, and herbivory; economic: impact on agriculture, livestock, forestry, human health, and infrastructure). We assigned all impact reports to one of these 10 categories. All categories had impact scores that ranged f...

2010-01-01

195

Point and transfer mobility of point-connected ribbed plates  

Science.gov (United States)

The work reported in this paper addresses the problem of structure-borne sound transmission between vibrating sources and ribbed-plate receiver structures. Vibrating sources, such as pumps, motors, fans, etc., transmit vibro-acoustic power, causing noise complaints by occupants in cars, trains, aircraft, buildings and/or material fatigue and damage. The transmission process is complicated in that sources transmit power through several contacts and by up to six components of excitation at each contact. The structure-borne sound power is a function of source activity, source mobility and receiver mobility, and all three quantities must be known to some degree. For non-homogeneous receiver structures, such as thin-plate cavity constructions or lightweight framed constructions, the sheathing plates are typically fastened to the framing members using bolts, screws or spot-welded joints. Hence the resulting system is a ...

2011-09-01

196

Market Brief : Turkey oil and gas pipelines  

International Nuclear Information System (INIS)

This report presented some quick facts about oil and gas pipelines in Turkey and presented opportunities for trade. The key players and customers in the oil and gas sector were described along with an export check list. Turkey is looking into becoming an energy bridge between oil and gas producing countries in the Middle East, Central Asia and Europe. The oil and gas sectors are dominated by the Turkish Petroleum Corporation, a public enterprise dealing with exploration and production, and the State Pipeline Corporation which deals with energy transmission. They are also the key buyers of oil and gas equipment in Turkey. There are several pipelines connecting countries bordering the Caspian Sea. Opportunities exist in the areas of engineering consulting as well as contracting services for oil and gas pipeline transmission and distribution. Other opportunities lie in the area of pipeline construction, rehabilitation, materials, equipment, ...

197

Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.  

Science.gov (United States)

A focused ion beam (FIB) technique was applied to cross-sectional specimen preparation to observe an interface between a plasma sprayed coating and an aluminum (Al) substrate by transmission electron microscopy (TEM). The surface of the sprayed coating film has a roughness of several tens of microns. Sputter rates for the coating film and the substrate are greatly different. The rough surface and the difference in sputter rate cause problems in making TEM specimens with smooth side walls. The top surface of the coating film was planerized by the FIB before fabricating the TEM specimen. The interfaces were investigated by TEM and energy-dispersive X-ray (EDX) analysis. The TEM observation revealed that there is a 10 nm thick amorphous layer at the interface between the coating film and substrate. The coating film consists of two kinds of sublayers with bright and dark contrast. The bright contrast sublayers were amorphous layers with thickness of 2 approximately 10 ...

2000-05-01

198

Combined Scanning Electron Microscope and Micro-InfraRed measurements on Interplanetary Dust Particles  

CERN Document Server

Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" ...

2007-01-01

199

A surface acoustic wave electric field strength meter for environmental studies of HV transmission lines  

International Nuclear Information System (INIS)

In recent years, there has been a significant increase in concern over the health and safety aspects of high voltage transmission lines (HVTL). The majority of research has focused on effects directly or indirectly involved with the central nervous system, including physiological, ultrastructural, and biochemical alterations, changes in blood composition, behaviour, reproduction, and development. Several recent epidemiological reports have presented preliminary data suggesting an increase in the incidence of cancer among children and adults exposed to magnetic fields through living close to various types of electrical power lines or devices. With the increase in environmental concerns there has been a concomitant consideration of biological effects and health implications related to presently existing HVTL and those planned in the future. It was concluded that the electric and magnetic field strengths and the electrical discharges are the most ...

1988-04-01

200

Loaded Transducer Fpr Downhole Drilling Component  

Energy Technology Data Exchange (ETDEWEB)

A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.

2005-07-05

201

When loss is more (for transmission towers) | SmartPlanet  

Wastenet

... ice, hurricanes, and trees (less likely on high voltage transmission lines ) can bring down above ground power lines. Flooding, Leeching ground ...

202

Transtelephonic Electrocardiographic Transmission in the Preparticipation Screening of Athletes  

UK PubMed Central (United Kingdom)

Transtelephonic electrocardiographic transmission (TET) is the most widespread form of telecardiology since it enables clinicians to assess patients at a distance. The purpose of this study was to assess...Full Text Available

2008-01-01

203

Defective Glycinergic Synaptic Transmission in Zebrafish Motility Mutants  

UK PubMed Central (United Kingdom)

Glycine is a major inhibitory neurotransmitter in the spinal cord and brainstem. Recently, in vivo analysis of glycinergic synaptic transmission has been pursued in zebrafish using...Full Text Available

204

Ultra high-speed (508 MHz) beam position digital feedback system  

Energy Technology Data Exchange (ETDEWEB)

The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters ...

1997-02-01

205

PILC cable technology and accessories  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it has proven to be effective over a wide range of pressure conditions. Test results ...

1996-08-01

206

Development of a leak location system for use on underground electric power transmission cable. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection ...

1982-10-01

207

Fiscal 1996 report on the results of the subsidy operation under the Sunshine Project on the development of a geothermal water use power plant, etc. Development of the binary cycle power plant (development of the measurement while drilling system for geothermal wells); 1996 nendo New Sunshine keikaku hojo jigyo seika hokokusho. Nessui riyo hatsuden plant nado kaihatsu (binary cycle hatsuden plant no kaihatsu (chinetsusei kussakuji kotei joho kenchi system no kaihatsu))  

Energy Technology Data Exchange (ETDEWEB)

The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. ...

1997-03-01

208

Direct energy conversion for IEC fusion for space applications  

Energy Technology Data Exchange (ETDEWEB)

The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a ...

2000-08-01

209

Determining the locations of faults in distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Location of transmission line faults are traditionally estimated by measuring the apparent impedance from a line terminal to the fault and converting the reactive component of the impedance to line length. None of the methods proposed to date address adequately the problems of fault location on distribution systems that have single or multiphase laterals and/or tapped loads. The research for this dissertation resulted in the development of a technique that estimates the location of a shunt fault on a radial distribution system that has several single and/or multiphase laterals. The technique takes into account load taps and non-homogeneity of the system, and has been tested for its ability to handle single-phase-to-ground, two-phase-to-ground, phase-to-phase and balanced three-phase faults. Computer simulations indicate that the technique is more accurate than the reactive component method. Results from ...

1998-12-01

210

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the ...

2009-06-17

211

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the ...

2007-08-21

212

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end ...

2007-08-21

213

Therapeutic Approaches to the Treatment of Botulism  

Science.gov (United States)

... above. In the initial round of experiments, the venom of Dendroaspis augustepsis was tested for its actions on neuromuscular transmission. ...

1989-10-01

220

Voltage and reactive power control by means of static compensators of vars in electric power systems; Control de voltaje y potencia reactiva mediante compensadores estaticos de Vars en sistemas electricos de potencia  

Energy Technology Data Exchange (ETDEWEB)

In this thesis a study is made of the of voltage characteristics and reactive power control in the transmission network of the Electric Power Systems (EPS) with static compensators of VARs (SCVs). The necessity of voltage and reactive power control and the application of SCVs as a solution means for three representative operation stages of the EPS, considering balanced operation conditions and fundamental frequency is analyzed: Operation in the presence of incremental voltage changes, quasi-stationary operation or steady state and behavior at the occurrence of big disturbances. The application of SCVs to systems of integral transmission is in general a closed loop control system, reason why the analysis of the interaction of the system EPS-SCV is considered as an essential part of the voltage and reactive power control study. Firstly, the response analysis of ...

1987-07-01

221

Study on vibration of transmission lines when gust is blowing (an interim report); Kyofuji no haiden senro no yodo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

As an interim report on the study on vibration of transmission lines when gust is blowing, this paper introduces events of confused and other contacts between transmission lines, photographing of transmission line vibration, physical measurement on transmission line response, and development of simulation software. Events of confused contacts of high-voltage transmission lines with overhead ground wires have the following common conditions: gust blows nearly perpendicularly to the line direction; no obstacles exist in upwind directions; the wind blows upward or downward against high-voltage transmission lines; and size of the high-voltage transmission lines is 25 mm{sup 2}. According to photographs of transmission line vibration, it appears that gust caused a high-voltage transmission line on the ...

1996-03-25

222

The antiviral action of common household disinfectants and antiseptics against murine hepatitis virus, a potential surrogate for SARS coronavirus  

British Library Electronic Table of Contents (United Kingdom)

Background The 2003 outbreak of severe acute respiratory syndrome (SARS) infected over 8000 people and killed 774. Transmission of SARS occurred through direct and indirect contact and large droplet nuclei. The World Health Organization recommended the use of household disinfectants, which have not been previously tested against SARS coronavirus (SARS-CoV), to disinfect potentially contaminated environmental surfaces. There is a need for a surrogate test system given the limited availability of the SARS-CoV for testing and biosafety requirements necessary to safely handle it. In this study, the antiviral activity of standard household products was assayed against murine hepatitis virus (MHV), as a potential surrogate for SARS-CoV. Methods A surface test method, which involves drying an amo...

2009-01-01

223

Sterically stabilized water based magnetic fluids: Synthesis, structure and properties  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluids (MFs), prepared by chemical co-precipitation followed by double layer steric and electrostatic (combined) stabilization of magnetite nanoparticles dispersed in water, are presented. Several combinations of surfactants with different chain lengths (lauric acid (LA), myristic acid (MA), oleic acid (OA) and dodecyl-benzene-sulphonic acid (DBS)) were used, such as LA+LA, MA+MA, LA+DBS, MA+DBS, OA+DBS, OA+OA and DBS+DBS. Static light scattering, transmission electron microscopy, small angle neutron scattering, magnetic and magneto-rheological measurements revealed that MFs with MA+MA or LA+LA biocompatible double layer covered magnetite nanoparticles are the most stable colloidal systems among the investigated samples, and thus suitable for biomedical applications.

2007-04-15

224

Status of electric power in the Missouri River Basin  

Energy Technology Data Exchange (ETDEWEB)

This third Missouri River Basin Commission report on Status of Electric Power in the Missouri River Basin provides information on the status of electric power generation, future needs, and potentials for meeting these needs. Information for this 1980 update is based upon available published information up to and including December 31, 1979. State and federal members of the Missouri River Basin Commission provided information for sections of the report and on legislative activities. Information is included on the planning and projected costs of hydro, nuclear and fossil-fuel power plants, pumped-storage plants, transmission systems, projected power demands, the environmental, socio-economic-cultural impacts of electric power generation, and regulations affecting energy development. (LCL)

1980-01-01

225

Silver nanoparticles prepared by chemical reduction-protection method, and their application in electrically conductive silver nanopaste  

Energy Technology Data Exchange (ETDEWEB)

Ag nanoparticles were prepared in a water-phase system with a mixture of silver-ammonia complex, sodium borohydride, and lauric acid according to molar feed ratio of approximately 6:3:1. The mechanism of preparation and separation by chemical reduction-protection method was explored. The as-synthesized Ag nanoparticles were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) and UV-vis spectroscopy, respectively. It was found that the size of high purity Ag particles was ranging from 30 to 50 nm with slight agglomeration. In addition, the as-synthesized wet Ag nanoparticles were dispersed stably in organic vehicle to formulate electrically conductive nanopaste. Upon direct-written and sintered, the array pattern of the nanopaste with the resolution of about 30 {mu}m was achieved with the electrical resistivity in the order of magnitude of 10{sup -5} {Omega} cm.

2010-04-02

226

Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro has been assessing and upgrading its facilities and implementing response alternatives to potential damage resulting from a major earthquake. This paper reviews the utility`s seismic evaluation of its overhead transmission system, focusing on the Lower Mainland area where most of the tall critical river-crossing towers are located. The paper gives an overview of the geologic environment of the Lower Mainland and outlines the criteria used for assessing existing structures for their ability to withstand design seismic loads. It then describes the investigation and analysis methods used in the assessment, including geotechnical field tests, ground response analysis, determination of soil liquefaction potential, and dynamic analysis of structures and piles. Options for seismic upgrades are discussed and illustrated by the case of the Pitt River crossing, where tower foundations were reinforced with steel pipe piles.

1995-12-31

227

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission lines as well as computer work-places. (orig.).

1993-01-01

228

Polymer Fuel Cells Challenge  

Wastenet

...Polymer Fuel Cells Challenge Publications News Events Login Register Search Content type All Web pages Case studies Publications News Video Home ...Buildings Carbon capture & storage Combined heat & power Electricity transmission & distribution Energy storage Fuel cells Geothermal Hydroelectric Hydrogen Industry Lighting Marine Metering Nuclear Solar Transport Wind ...Home Emerging technologies Current focus areas Polymer Fuel Cell Challenge Polymer Fuel Cells Challenge The objective of the Polymer Fuel Cells Challenge is to develop,...prove and commercialise novel polymer fuel cell technologies that have the potential to deliver a step-change in overall system cost. What are ...

229

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

230

PSPs at Bhira and Bhivpuri  

International Nuclear Information System (INIS)

Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.

1992-01-01

231

Magnetically applied pressure-shear : a new technique for direct strength measurement at high pressure (final report for LDRD project 117856).  

Energy Technology Data Exchange (ETDEWEB)

A new experimental technique to measure material shear strength at high pressures has been developed for use on magneto-hydrodynamic (MHD) drive pulsed power platforms. By applying an external static magnetic field to the sample region, the MHD drive directly induces a shear stress wave in addition to the usual longitudinal stress wave. Strength is probed by passing this shear wave through a sample material where the transmissible shear stress is limited to the sample strength. The magnitude of the transmitted shear wave is measured via a transverse VISAR system from which the sample strength is determined.

2010-09-01

232

High channel density wavelength division multiplexer with defined diffracting means positioning  

Energy Technology Data Exchange (ETDEWEB)

A wavelength division multiplexer/demultiplexer having optical path lengths between a fiber array and a Fourier transform lens, and between a dispersion grating and the lens equal to the focal length of the lens. The optical path lengths reduce losses due to angular acceptance mismatch in the multiplexer. Close orientation of the fiber array about the optical axis and the use of a holographic dispersion grating reduces other losses in the system. Multi-exposure holographic dispersion gratings enable the multiplexer/demultiplexer for extremely broad-band simultaneous transmission and reflection operation. Individual Bragg plane sets recorded in the grating are dedicated to and operate efficiently on discrete wavelength ranges.

1990-01-01

233

Flywheel rotor and containment technology development, FY83  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy decided to terminate the Flywheel Rotor and Containment Technology Development project during FY 1983. Activities this year included fabrication, inspection, and test evaluation of rotor and containment structures. A peak energy of 700 Wh was stored at an energy density of 70 Wh/kg. In cyclic tests, 10,000 cycles from design speed to half speed were logged without failure. The first test of a lightweight containment structure indicates the need for additional development. In complementary studies, production cost estimates were made for three flywheel designs. In a cooperative program with the University of Wisconsin, work began on construction of a flywheel/continuously variable transmission/heat engine car which promises fuel economy improvements of up to 100%. Suggestions are made for the direction of future work when interest in flywheel system reappears.

1983-09-12

234

Fault location observability analysis and optimal meter placement based on voltage measurements  

British Library Electronic Table of Contents (United Kingdom)

Various transmission line fault location algorithms have been proposed in the past depending on measurements available. These methods evince that if a sufficient number of meters are placed in a power network to record the fault measurements, then the fault location can be reliably estimated. A relevant question to ask may be: how many meters are sufficient in order to derive a reliable and unique fault location estimate for a given network? This paper addresses this question by defining and performing the fault location observability analysis. An optimal meter placement scheme is proposed for determining the optimal locations to place meters so as to make the system observable while minimizing the required number of meters to reduce costs. The proposed method is especially useful for powe...

2009-01-01

235

Evaluation of HVDC cables for the St. Lawrence crossing of Hydro-Quebec 500 kV DC Line. Part 1; Dielectric and accelerated aging tests on prototypes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.

1992-04-01

236

Economic study of a rural underground transmission system: A site-specific case study: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the data and results of a site specific case study comparing costs of an overhead line with an underground circuit traversing the same route. The costs used for the overhead line are actual numbers for a line scheduled to be built by a utility. The underground circuit costs were developed using the same criteria of line rating, contingencies, and location. Often cost comparisons between overhead and underground lines are made using figures taken from studies with widely varying assumptions. This project attempts to provide a comparison by studying the costs of overhead and underground lines following the same route and using the same design assumptions. Caution must be used, however, in extending the results of this study beyond its original intent. It is site-specific and may be representative of only one area of the country. 9 refs., 23 figs., 18 tabs.

1987-10-01

237

Disordered bcc γ-phase to δ-phase transformation in Zr-rich U-Zr alloy  

British Library Electronic Table of Contents (United Kingdom)

The transformation mechanism of hexagonal delta phase from the disordered bcc gamma phase has not been reported before in the Zr-rich U-Zr alloy system. With the help of X-ray diffraction, transmission electron microscopy (TEM) and high-resolution TEM analyses it was shown that the gamma to delta conversion takes place by the lattice collapse mechanism of omega transformation. It was also ascertained that a higher aging temperature or time promotes the growth of all four variants of the delta phase within a parent gamma grain. In addition, ab initio electronic structure calculations showed that the bcc to hexagonal transformation, involving partial ordering of the parent bcc phase followed by (111) plane collapse, is energetically favorable.

2011-01-01

238

De-icing technologies: Introduction to Manitoba Hydro's use of ice melting and ice rolling technologies to remove ice from subtransmission and 115 kV transmission lines  

International Nuclear Information System (INIS)

Manitoba Hydro's Ice Storm Management Program to reduce ice damage to overhead power lines in the voltage range of 8 kV to 115 kV is described. Overhead power lines are de-iced either by AC ice melting, which involves placing a three-phase short at a calculated point, or ice rolling, which is a process of mechanically stripping ice from conductors. Direct current heating and underground distribution systems are also accepted prevention measures. Advantages and disadvantages of each of these methods of de-icing are reviewed. Material for this paper has been extracted from a workshop manual prepared for the 1993 and 1998 Ice Storm Management workshops organized by Manitoba Hydro through the Canadian Electrical Association. 1 ref.

1999-03-29

239

Danger: high voltage  

Science.gov (United States)

Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmission lines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central nervous system. Full disclosure that possible risks are involved and the opportunity to avoid these risks is ...

1978-05-01

240

Coupled mechanical and chemical processes in engineered geothermal reservoirs with dynamic permeability  

British Library Electronic Table of Contents (United Kingdom)

A model is developed to represent mechanical strain, stress-enhanced dissolution, and shear dilation as innately hysteretic and interlinked processes in rough contacting fractures. The model is incorporated into a numerical simulator designed to examine permeability change and thermal exchange in chemically active and deformable fractured reservoirs. A candidate engineered geothermal reservoir system (EGS) is targeted. The mechanistic model is able to distinguish differences between the evolution of fluid transmission characteristics of (1) small scale, closely spaced fractures, and (2) large-scale, more widely spaced fractures. Alternate realizations of fracture frequency and scale, exhibiting identical initial bulk permeability, lead to significantly different conclusions regarding perme...

2010-01-01

241

Application of GIS for the evaluation of human exposure to magnetic field in the vicinity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.

1998-10-01

242

A free topology safeguards network  

Energy Technology Data Exchange (ETDEWEB)

Free Topology Network technology provides cost reduction benefits as well as flexibility in safeguards applications. Power line communications technologies have proven viability for transmission and reception of safeguards data, including surveillance photographs, the source of the largest data files. In the future, enhancements will be made to the technology that should boost both performance and flexibility. Work is already underway to achieve higher data rates over power line communications eventually, it should be possible to reach data rates of one million bits per second or higher. Also, the use of technologies such as Novell Embedded Systems Technology (NEST) and Echelon LON technology will allow a greater number of safeguards technologies to become resident on the Free Topology Safeguards Network.

1995-12-31

243

A free topology safeguards network  

International Nuclear Information System (INIS)

Free Topology Network technology provides cost reduction benefits as well as flexibility in safeguards applications. Power line communications technologies have proven viability for transmission and reception of safeguards data, including surveillance photographs, the source of the largest data files. In the future, enhancements will be made to the technology that should boost both performance and flexibility. Work is already underway to achieve higher data rates over power line communications eventually, it should be possible to reach data rates of one million bits per second or higher. Also, the use of technologies such as Novell Embedded Systems Technology (NEST) and Echelon LON technology will allow a greater number of safeguards technologies to become resident on the Free Topology Safeguards Network.

1995-07-09

244

Report on the Swedish National Energy Administration's program for energy efficiency 1998-2001; Redovisning av Energimyndighetens insatser foer energieffektivisering aaren 1998-2001  

Energy Technology Data Exchange (ETDEWEB)

Support for raising energy efficiency is reported for the following five areas during 1998-2001: 1. Fuel-based energy systems with the sub-areas: Sustainable production of biofuels, including ash recycling; Cogeneration; and Large scale heat production. 2. Transport with two sub-areas: Internal combustion engines; and Electric drive-lines. 3. Power production/Power technology with the sub-areas: Hydropower; Wind power; Power transmission and distribution; and Photovoltaic solar cells. 4. Industry with the sub-areas: Processes; and Support systems in industry. 5. Buildings with the sub-areas: Heating, cooling and climatic shields; and Components and support systems. In total, 1,800 M SEK (about 180 M USD) was contributed by the Energy Administration during this period. An overview of the projects is presented in this report.

2002-01-01

245

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average value of the void ...

1992-11-12

246

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of ...

247

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and measurements are explained.

2005-01-01

248

Difference Antenna Selection and Power Allocation for Wireless Cognitive Systems  

CERN Document Server

In this paper, we propose an antenna selection method in a wireless cognitive radio (CR) system, namely difference selection, whereby a single transmit antenna is selected at the secondary transmitter out of $M$ possible antennas such that the weighted difference between the channel gains of the data link and the interference link is maximized. We analyze mutual information and outage probability of the secondary transmission in a CR system with difference antenna selection, and propose a method of optimizing these performance metrics of the secondary data link subject to practical constraints on the peak secondary transmit power and the average interference power as seen by the primary receiver. The optimization is performed over two parameters: the peak secondary transmit power and the difference selection weight $\\delta\\in [0, 1]$. We show that, difference selection using the optimized parameters determined by the ...

2010-01-01

249

Cable-to-air terminations: The cable system's second weakest link  

Energy Technology Data Exchange (ETDEWEB)

Transmission terminations available today are very reliable, but they need to be. In the field, they are continually exposed to pollution and extremes of ambient temperature. In many cases, they are in the rifle sights of vandals. In contrast, cable joints - often cited as the weakest links from an electrical viewpoint - are generally protected from physical damage underground and many of the short cable systems being installed in the US today can be built without joints. All cable systems need terminations - mostly to air-insulated equipment. At 69 through 138 kV, there is intense competition among manufacturers to supply terminations for solid-dielectric cable that are low in cost, reliable, and require a minimum of skill to install. Some utilities are looking also for terminations that fit a range of cable sizes; terminations that do not contain liquid that can leak out; and terminations that are shatter-proof. All of ...

1994-12-01

250

Two-gigawatt burst-mode operation of the intense microwave prototype (IMP) free-electron laser (FEL) for the microwave tokamak experiment (MTX)  

Energy Technology Data Exchange (ETDEWEB)

The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the parameter space of the IMP FEL, and finally evaluate ...

1993-10-06

251

New trends in electricity pricing in Sweden from a utility perspective  

Energy Technology Data Exchange (ETDEWEB)

Sweden is facing a re-structured electricity market beginning January 1, 1996, implying full competition in the purchasing and selling of electricity. The transmission and distribution of electricity will remain as a franchised monopoly and this business has to be strictly separated from the electricity trading. In the monopolistic environment, pricing of electricity has been based on more or less relevant costs and a resonable rate of return. The energy charges have reflected the system short range marginal costs while the demand and fixed charges have been adapted to give a total cost level corresponding to the system average cost. Tariffs of this type, known as time-of-use tariffs, have stimulated peak shaving during peak load (high cost hours) and valley filling during low load (low cost hours), increasing the load factor. Restructuring will influence the pricing in several ways. Pricing of ...

1996-03-01

252

A MAC protocol for cognitive wireless sensor body area networking  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-critical health information and nodes of non-critical health information. The CR-MAC protocol prioritizes the critical packets access to the transmission medium by transmitting them with higher power while transmitting lower priority packets using lower transmission power. At the receiver, a higher priority packet experiences collision only when there are more than one critical packet transmission at the same transmission slot while non critical packets experience collision when there are more than one transmission at the same transmi...

2010-01-01

253

The intelligent communications platform, or putting the smart into the smart grid  

Energy Technology Data Exchange (ETDEWEB)

North American technologies designed to improve electricity transmission and distribution systems were discussed. Legislation in the United States and Canada is now being implemented to ensure the widespread adoption of advanced metering technologies. Grid technologies will also be expected to address carbon dioxide (CO{sub 2}) emissions, as governments are now encouraging investment in distributed generation technologies such as solar, wind, and biodiesel energy. It is expected that smart grid systems will provide increased reliability, interoperability, 2-way communications, risk management services, and have the capacity to support new power resources. Devices will be added to the overall system in order to support smart metering applications. Advanced metering infrastructure (AMI) will use automated measurements of time-of-use energy consumption. Improved outage management detection and restoration ...

2008-11-15

254

Energy analysis of a solar pre-water heating system; Analise energetica de um sistema de pre-aquecimento solar de agua  

Energy Technology Data Exchange (ETDEWEB)

Several technological alternatives have been studied taking into consideration that one of the biggest problems of the electric power companies is to provide electric power during the peak consumption periods, which largest contribution to the increase of the demand comes from the residential sector, especially by the use of electric showers. One of the most promising alternatives is the pre-water heating system for reduced power showers, developed by Universidade de Campinas and Companhia Paulista de Forca e Luz. The goal of this system is basically to reduce demand during the peak periods, in order to avoid heavy investments by the electric power companies in generation, transmission and distribution of electric power directed to low acquisitive power customers, a sector in which the electric power price is not enough to recover such investments. The objective of this paper is to evaluate the total energy required in the ...

1996-12-31

255

A decision support technique for the analysis of autonomous and grid-connected renewable energy systems  

International Nuclear Information System (INIS)

There is an increasing interest in using novel methods to generate electrical energy using wind and solar energy sources. Unfortunately, such energy sources are intermittent, and, therefore, conventional sources must still be available to meet demand during critical periods. In addition, renewable energy technologies are still expensive in general, although extensive research programs are being conducted to overcome this disadvantage. Hence, reliability, economic assessment and environmental impacts are three objectives to be satisfied simultaneously when designing either an autonomous or a grid-connected hybrid power generation system. The installation of any of these two systems should, undoubtedly, be preceded by an assessment of the available resources at the candidate site. In addition, many other factors are to be studied, including economics of transmission lines, site constraints, distances etc. In this thesis, the ...

256

The condition monitoring of fluid-filled taped cables employed in underground transmission through dissolved gas analysis  

Energy Technology Data Exchange (ETDEWEB)

There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal cable systems as demonstrated by DGA. The concept of wet tensile strength has been introduced to the ...

1994-12-31

257

Outlook for using wind energy for electrification of agriculture in Estonian SSR  

Energy Technology Data Exchange (ETDEWEB)

The developed electrical networks in the agricultural regions of the Estonian SSR make it possible to construct relatively powerful wind power plants at the sites of the most favorable wind conditions with small outlays for the power transmission lines. The wind power plant electricity can be used to electrify the production processes in agriculture, while the surplus can be supplied to the energy system. The inclusion of the wind power plants in the energy system makes it possible to improve the total generation of energy or reduce the consumption of fuel. With the efficient arrangement of the wind power plants, one can also reduce the energy losses during its transfer. Calculations indicated that in the coastal zones of the Estonian SSR, one can obtain specific power of 420-480 kW/km/sup 2/. For comparison it is indicated that the Estonian SSR in the agricultural regions now uses 8-12 kW/km/sup 2/. The wind-energy ...

1982-01-01

258

Modeling paraxial wave propagation in free-electron laser oscillators  

International Nuclear Information System (INIS)

Modeling free-electron laser (FEL) oscillators requires calculation of both the light-beam interaction within the undulator and the light propagation outside the undulator. We have developed a paraxial optical propagation code that can be combined with various existing models of gain media, for example, Genesis 1.3 for FELs, to model oscillators with full paraxial wave propagation within the resonator. A flexible scripting interface is used both to describe the optical resonator and to control the codes for propagation and amplification. To illustrate its capabilities, we numerically investigate two significantly different FEL oscillators: the free-electron laser for infrared experiments (FELIX) system and the vacuum-ultraviolet (VUV)-FEL oscillator of the proposed high-gain fourth generation light source. For the FELIX system, we find that diffraction losses are a considerable part of the single-pass cavity loss (at a wavelength of 40 #mu#m). ...

2006-11-01

259

Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis  

International Nuclear Information System (INIS)

The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including Fresnel lens and phase ...

2003-06-01

260

Energy-filtered electron microscopy for imaging core-shell nanostructures  

Energy Technology Data Exchange (ETDEWEB)

CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the core-shell arrangements in ...

2008-08-15

261

Electron flow in the SABRE linear induction adder in positive polarity  

International Nuclear Information System (INIS)

In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have ...

1993-05-17

262

Effects of extreme pressure additive chemistry on rolling element bearing surface durability  

Energy Technology Data Exchange (ETDEWEB)

Lubricant additives have been known to affect rolling element bearing surface durability for many years. Tapered roller bearings were used in fatigue testing of lubricants formulated with gear oil type additive systems. These systems have sulfur- and phosphoruscontaining compounds used for gear protection as well as bearing lubrication. Several variations of a commercially available base additive formulation were tested having modified sulfur components. The variations represent a range of ''active'' extreme pressure (EP) chemistries. The bearing fatigue test results were compared with respect to EP formulation and test conditions. Inner ring near-surface material in selected test bearings was evaluated on two scales: the micrometer scale using optical metallography and the nanometer scale using transmission electron microscopy (TEM). Focused-ion beam (FIB) techniques were used for TEM ...

2007-08-01

263

Abundance of West Nile virus mosquito vectors in relation to climate and landscape variables.  

Science.gov (United States)

It is currently unclear if the potential for West Nile virus transmission by mosquito vectors in the eastern United States is related to landscape or climate factors or both. We compared abundance of vector species between urban and suburban neighborhoods of Henrico County, VA, in relation to the following factors: temperature, precipitation, canopy cover, building footprint, and proximity to drainage infrastructure. Mosquitoes were collected throughout the 2005, 2006, and 2007 seasons and tested for West Nile virus (WNV) in pools of 10-50. Test results of mosquito pools were compared to average site abundance from 37 sites in Henrico County, VA; abundance was then examined in relation to ecological variables. Urban infrastructure was positively correlated with the abundance of Culex pipiens L./Cx. restuans, and our findings implicate combined sewer overflow systems as large contributors to Culex vector populations. No measure of urbanization ...

2011-06-01

264

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical model of simultaneous ...

1985-10-01

265

Modeling, Simulation Design and Control of Hybrid-Electric Vehicle Drives  

Energy Technology Data Exchange (ETDEWEB)

Ohio State University (OSU) is uniquely poised to establish such a center, with interdisciplinary emphasis on modeling, simulation, design and control of hybrid-electric drives for a number of reasons, some of which are: (1) The OSU Center for Automotive Research (CAR) already provides an infrastructure for interdisciplinary automotive research and graduate education; the facilities available at OSU-CAR in the area of vehicle and powertrain research are among the best in the country. CAR facilities include 31,000 sq. feet of space, multiple chassis and engine dynamometers, an anechoic chamber, and a high bay area. (2) OSU has in excess of 10 graduate level courses related to automotive systems. A graduate level sequence has already been initiated with GM. In addition, an Automotive Systems Engineering (ASE) program cosponsored by the mechanical and electrical engineering programs, had been formulated earlier at OSU, independent of the GATE ...

2005-09-30

266

The relationship between the Plasmodium falciparum parasite ratio in childhood and climate estimates of malaria transmission in Kenya  

UK PubMed Central (United Kingdom)

BackgroundPlasmodium falciparum morbid and fatal risks are considerably higher in areas supporting parasite prevalence ≥25%, when compared with low transmission...Full Text Available

267

The effects of high voltage transmission lines on the health of adjacent resident populations.  

UK PubMed Central (United Kingdom)

A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant...Full Text Available

1984-01-01

268

Risks of leukaemia among residents close to high voltage transmission electric lines.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To reassess the risk of leukaemia associated with residential exposure near high voltage transmission electric lines of 49 kV and above in view of the recent publications. METHODS: Through...Full Text Available

1997-09-01

269

Preliminary parasitological results of a pilot mollusciciding campaign to control transmission of Schistosoma mansoni in St Lucia*  

UK PubMed Central (United Kingdom)

A mollusciciding campaign was begun in Cul-de-Sac Valley, St Lucia, at the end of 1970, following several years of epidemiological studies in which transmission of Schistosoma mansoni...Full Text Available

1976-01-01

270

Nonlinear transmission of two successive ultrashort laser pulses by a thin semiconductor film under two-photon generation of biexcitons. Giant oscillator strength model  

International Nuclear Information System (INIS)

The possibility to compress and to split laser pulses at their nonlinear optical transmission through semiconductor films was investigated

2011-07-07

271

Mitochondrial transmission during mating in Saccharomyces cerevisiae is determined by mitochondrial fusion and fission and the intramitochondrial segregation of mitochondrial DNA.  

UK PubMed Central (United Kingdom)

To gain insight into the process of mitochondrial transmission in yeast, we directly labeled mitochondrial proteins and mitochondrial DNA (mtDNA) and observed their fate after the fusion of two cells....Full Text Available

1997-07-01

272

In situ nanoindentation in a transmission electron microscope  

Science.gov (United States)

This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.

2002-12-02

273

Entry and release of transmissible gastroenteritis coronavirus are restricted to apical surfaces of polarized epithelial cells.  

UK PubMed Central (United Kingdom)

The transmissible gastroenteritis coronavirus (TGEV) infects the epithelial cells of the intestinal tract of pigs, resulting in a high mortality rate in piglets. This study shows the interaction of...Full Text Available

1994-12-01

274

A nested case-control study of maternal-neonatal transmission of hepatitis B virus in a Chinese population  

UK PubMed Central (United Kingdom)

AIM: To examine the determinants of maternal-neonatal transmission of hepatitis B virus (HBV).METHODS: A nested case-control study was conducted in Changsha, Hunan, People’s Republic...Full Text Available

2011-08-21

275

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement ...

1997-02-28

276

Global positioning automatic vehicle location system  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global ...

1997-03-01

277

Early failure detection of damages of roller bearing in frequency variable wind power gears. Internal analysis methods in CM systems; Fehlerfrueherkennung von Waelzlagerschaeden in drehzahlvariablen Windgetrieben. Interne Analysemethoden in CM-Systemen  

Energy Technology Data Exchange (ETDEWEB)

In the past, Condition Monitoring Systems (CMS) still showed weaknesses during the employment in the damage diagnosis and/or early failure detection of damages of roller bearings in transmissions of wind power plants. This is not only due to the insufficient consideration of the variable frequency of the wind power plants during the internal processing. The presently used methods of analysis result from the communication technology and are used successfully for years at frequency solid systems. Usually, only too few information are at the disposal to the supplier of CMS in order to parametrize their systems on the respective application particularly. An exact knowledge of the internal structure of the object to be diagnosed is compellingly necessary for a successful diagnosis so that a loadable statement based on the acquired measuring data base becomes possible. Furthermore, one must clarify the ...

2010-07-01

278

Vibration Transmissibility Characteristics of Occupied ...  

Science.gov (United States)

... The relatively large, low frequency multi-axis motions observed at the chest may be a contributor to discomfort in locomotive engineers. ...

2006-09-01

279

The effect of high voltage transmission lines on agricultural land values in minnesota  

Energy Technology Data Exchange (ETDEWEB)

Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.

1981-04-01

280

The effect of high voltage transmission lines on agricultural land values in Minnesota  

Energy Technology Data Exchange (ETDEWEB)

Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.

1981-04-01

281

NEUROPLASTICITY and INNOVATION  

Science.gov (United States)

OF VOCALIZED SPEECH THROUGH. ANALYSIS OF NEURAL SIGNALS. " SYNTHETIC TELEPATHY- WIRELESS. TRANSMISSION OF DECODED. THOUGHTS. " IMPLANTABLE MEMORY-ELIMINATES ...

282

Microsoft Word - June 11 Profile.doc  

Wastenet

These pipeline networks transport gas from WA's major onshore transmission pipelines to commercial and residential customers in

283

High voltage transmission lines - what are the hazards  

International Nuclear Information System (INIS)

With the increasing use of high voltage alternating current (HVAC) transmission lines there is a growing concern among the public about possible human health effects resulting from exposure to the electric fields associated with these lines. While there is no definitive evidence of such effects, mounting public fear and activism over hypothesized health risks is already causing delays in the licensing and constuction of major power transmission facilities, and is encouraging the formation of regulatory policy. This paper briefly reviews the concerns, biological effects data and standards for HVAC transmission lines.

1984-07-01

284

Effects of gamma irradiation on the sperm transmission and oviposition response in Helicoverpa armigera (L. NOCTUIDAE)  

International Nuclear Information System (INIS)

Transmissions of sperm by unirradiated and irradiated cotton bollworm, Helicoverpa armigera, were studied by live dissection of females immediately after the initiation of mating. In cotton bollworm the sperm transfer was rather a complex process. In fact unirradiated males failed to transfer sperm in about 19% of their matings. When irradiated with 250 Gy and 400 Gy, aberrations of sperm transmission were about 21% and 50% respectively. The failure of spermatophore 'cap' location was an important reason of sperm transmission aberrations. When females mated to high-dose-irradiated males, their oviposition response appeared abnormal

2002-02-01

285

Basic Research Leading to Compact, Portable Pulsed Power  

Science.gov (United States)

... 1 ..... 14 High Dielectric Constant Ceramics for Use in Blumlein Transmission Lines ..... 14 ...

2007-03-31

286

An accurate fault location on mutually coupled transmission lines using synchronized sampling  

Energy Technology Data Exchange (ETDEWEB)

The mutual inductance between parallel transmission lines influences the locating of the transmission line faults. A fault location algorithm for parallel lines developed in this paper takes into account the magnetic coupling between parallel lines. The paper presents a detailed description of the developed algorithm and test results performed on a simplified real transmission line. The obtained error is less than 0.5 percent in most cases. Also, the developed algorithm is not sensitive to typical fault parameters, such as: resistance, type, location, and incidence angle. 7 refs, 4 figs, 12 tabs

1995-12-31

287

An Evaluation of the Severity of the January 1998 Ice Storm in ...  

Science.gov (United States)

... storm. There was little damage to high-voltage transmission lines and communication towers in northern New England. ...

1998-04-01

288

Peculiarities of Swift Proton Transmission through Tapered Glass Capillaries  

International Nuclear Information System (INIS)

A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)

2011-07-01

289

Fault prediction on high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The prediction of faults on high voltage transmission lines requires the detection of incipient faults, which is implemented by detection of the radio noise due to contaminated insulators, insulation deterioration, and improver connections. It is shown that the radio noise due to incipient faults is separable and identifiable from normal transmission line radio noise, hence faults can be predicted.

1982-12-01

290

Evaluation of lightning-induced overvoltages for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper presents some results of lightning induced over voltages for a typical high voltage transmission line configuration. The authors developed an elaborated electromagnetic coupling between the lightning channel and characteristics and the resulting induced overvoltage. The lightning current parameters, for local data, in order to determine the occurrence severity for high voltage transmission lines. (author)

2001-07-01

291

Optimizing an analytical dose calculation algorithm for fast 2D calculations  

International Nuclear Information System (INIS)

Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the dose calculation model is implemented in ...

292

Food packaging and radiation sterilization  

International Nuclear Information System (INIS)

Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The #gamma# ray and an electron beam are commonly used in radiation sterilization. The #gamma# ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing ...

1998-12-08

293

3D Atlas vertical plate oil transmission line field calculations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Because of questions regarding current density and inductance estimates of the Atlas oil transmission line in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for design 3 current density is 17MA/m. Maximum current density on the hot plates is 20MA/m for all 3 designs. These values assumed 1.2MA per VTL or ...

1997-09-18

294

Analysis of coupled neutron-gamma radiations by the multigroup Albedo method applied to multilayered slab shieldings  

International Nuclear Information System (INIS)

Full text: The principal nuclear design tools available to the shielding designer include diffusion approximation, transport theory, and Monte Carlo techniques. Full transport theory or Monte Carlo methods are routinely used for shielding analyses, where penetration investigations are more sensitive to directional aspects. However, the aim of this paper is to illustrate the coupled neutron-gamma Albedo method particularly as applied to problems of shielding analysis. The multigroup Albedo method is applied to coupled neutron-gamma radiations considering 'n' neutron energy groups and 'g' gamma energy groups to estimate the probabilities of transmission through, absorption in, and reflection from shieldings composed by multiple material layers, 'm' slabs, in which no fission occurs. In this study, these energy groups were selected in order to minimize upscattering effects of the radiation from lower energy groups to higher energy groups. However, neutrons of all ...

295

SSAC at Your Service: Promoting Co-operation Between IAEA and Finnish SSAC for Safeguards Implementation (Within the EU)  

International Nuclear Information System (INIS)

As the nuclear world is changing, the non-proliferation and safeguard systems have to change along the global development. Nuclear security as well as safety must be involved in all phases. Thus, modernization of thinking is a must. State system of accounting for and control of nuclear material (SSAC) is a basis, but now it is time to move ahead. Safeguards is not any more only to verify the declared nuclear materials but it is to inform the international safeguards society transparently but confidentially about the nuclear fuel cycle related activities and trade, and to confirm that there are no undeclared activities related to the nuclear fuel cycle in the states. Only strong SSAC with enhanced capabilities, activities and rights can meet the demand. The proliferation of nuclear weapons is a threat that also urges cooperation at all levels. International, regional and state systems must work closely together, and there is ...

2010-11-01

296

Radwaste Drum Assay Technology by Segmented Gamma Scanning System  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential ...

2009-01-15

297

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target ...

2010-05-01

298

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1996-11-01

299

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1995-10-01

300

Radio and television interference caused by corona discharges from high-voltage transmission lines  

International Nuclear Information System (INIS)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1996-04-09

301

Optimum arrangements of the phase conductors of overhead transmission lines for the electric field minimization  

Energy Technology Data Exchange (ETDEWEB)

The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.

1997-12-31

302

Optimum arrangements of the phase conductors of overhead transmission lines for the electric field minimization  

International Nuclear Information System (INIS)

The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.

1997-08-24

303

High-Voltage Transmission Lines: The Ongoing Search for Biological Effects.  

Energy Technology Data Exchange (ETDEWEB)

During the early 1970s, controversy developed over the possible biological effects of electric fields from new 500-kilovolt and 765-kilovolt transmission lines. This, along with growing interest in advancing transmission voltage into the ultrahigh-voltage range (1000 kilovolts and above), led to the initiation of numerous research projects. Several reviews of this research by scientists in the US and other countries indicate that transmission lines have not been proven to be a health hazard to people or animals. The issue remains controversial, however, because research has confirmed some subtle effects of electric fields, and because it is an inseparable part of the public opposition that often accompanies the siting of high-voltage transmission lines. In addition, there is renewed interest in magnetic fields, including a possible association between such fields and human cancers. 2 figures, 2 tables.

1984-12-20

304

Visible light emitting vertical cavity surface emitting lasers  

Science.gov (United States)

A vertical cavity surface emitting laser that emits visible radiation is built upon a substrate, then having mirrors, the first mirror on top of the substrate; both sets of mirrors being a distributed Bragg reflector of either dielectrics or other materials which affect the resistivity or of semiconductors, such that the structure within the mirror comprises a plurality of sets, each having a thickness of {lambda}/2n where n is the index of refraction of each of the sets; each of the mirrors adjacent to spacers which are on either side of an optically active bulk or quantum well layer; and the spacers and the optically active layer are from one of the following material systems: In{sub z}(Al{sub y}Ga{sub 1{minus}y}){sub 1{minus}z}P, InAlGaAs, AlGaAs, InGaAs, or AlGaP/GaP, wherein the optically active region having a length equal to m {lambda}/2n{sub eff} where m is an integer and n{sub eff} is the effective index of refraction of the laser cavity, and the spacer ...

1995-06-27

305

Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument  

International Nuclear Information System (INIS)

Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, which can be attached ...

2008-08-01

306

Underground high-power transmission: first results of testing a 110 kV lowpressure oil-filled cable with a water cooled conductor in Berlin (West), Germany  

Energy Technology Data Exchange (ETDEWEB)

The Berliner Kraft- u. Licht (BEWAG)AG have been conducting investigations during the last several years on a 110 kV low-pressure oil-filled high-power cable with a water cooled conductor and a load capacity of 950 MVA at 110 kV. After successful transport of the cable drums (weight: 16 metric tons; diameter: 4.9 m) from the manufacturing in Cologne, West Germany, to Berlin (West), and after laying of the cable over a 300 m stretch, the commissioning tests in accordance with IEC and VDE* standards have been concluded, and several loadings with a current of 5000 A have been performed. Now, after completion of various improvements in the test system, preparations are underway for initiation of long-term testing over a period of approx. 18 months.

1982-07-01

307

U. K. continental shelf due 800 miles of pipeline in 1993  

Science.gov (United States)

This paper reports that more than 800 miles of pipeline will come into service on the U.K. continental shelf during 1993, surpassing by 75% the previous record set in 1977. About 3,500 miles of pipeline is in place. Commissioning of the Miller natural gas pipeline and Scottish Area Gas Evacuation (SAGE) network this year and start-up of the Central Area Transmission System (CATS) next year will bring more than 600 miles of pipeline into use during 1993. The projects are part of a recent development boom in the central North Sea. In a review of U.K. offshore pipeline, analyst County Natwest Woodmac reported that projects totaling about 1,250 miles of pipeline have been sanctioned but are not yet operating. Two thirds of this total is gas pipeline, while 60s made up of main lines from shore to platform. County Natwest says that in most cases spur lines will be used to connect new fields with existing infrastructure. The analyst sees 57 ...

1992-08-17

308

The radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature  

International Nuclear Information System (INIS)

Generally, neutron, ion and electron Irradiations cause a substantial amount of hardening and significantly alter the deformation behavior of metals and alloys at relatively low irradiation temperatures. A radiation hardening is caused by the formation of microstructural defects such as dislocation loops, voids and precipitates under irradiation. Therefore, it is important to have a better knowledge of the irradiation induced microstructural defects under irradiation condition. As a part of the National mid- and long-term atomic energy R and D program, we are dealing with the radiation hardening behavior in Fe-Cr binary alloy. Fe-Cr binary alloy is a base alloy of Ferritic/Martensitic steel(F/M steel) planning to use for the Gen IV nuclear system. In this work, we investigated the radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature using nano-indentation measurement and ...

2009-05-01

309

The cooperative housing society Vaarst Vestervang - green building; Andelsboligforeningen Vaarst Vestervang - groent byggeri  

Energy Technology Data Exchange (ETDEWEB)

Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in relation to the forms of space and water heating ...

1993-10-01

310

The clustering and transmission dynamics of pandemic influenza A (H1N1) 2009 cases in Hong Kong  

British Library Electronic Table of Contents (United Kingdom)

Objectives: Human influenza A (H1N1) 2009 has caused severe epidemics in many countries, but its dynamics in spatial and temporal contexts have so far been poorly appreciated. Methods: A total of 24,414 laboratory confirmed human influenza A (H1N1) 2009 cases reported from May to September 2009 in Hong Kong were evaluated, using a Geographic Information System (GIS)-based approach. Spatio-temporal clustering was assessed after dividing Hong Kong into 4 geographic sectors, 18 districts and 500 m x 500 m cells. Global Moran's I, Local Moran's I and SaTScan(TM) were used in the exploration. Results: Spatio-temporal clusters first appeared on Hong Kong Island at week 3, alongside multiple foci suggestive of infection nidus introduced from abroad. The clusters grew rapidly and became confluent ...

2011-01-01

311

Photovoltaic Technologies Beyond the Horizon: Optical Rectenna Solar Cell, Final Report, 1 August 2001-30 September 2002  

Energy Technology Data Exchange (ETDEWEB)

ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were proposed to extend the rectennas into the IR and optical region of the ...

2003-02-01

312

Passive heat transfer augmentation in a cylindrical annulus utilizing multiple perturbations on the inner and outer cylinders  

Energy Technology Data Exchange (ETDEWEB)

The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise ...

1999-05-14

313

Passive heat transfer augmentation in a cylindrical annulus utilizing multiple perturbations on the inner and outer cylinders  

International Nuclear Information System (INIS)

The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise ...

1999-05-14

314

NOVA Corporation of Alberta annual report, 1992  

International Nuclear Information System (INIS)

Nova Corporation and its related businesses are involved in natural gas production, gas pipelines, consulting services, and upgrading of natural gas into chemicals and plastics. Nova owns Alberta Gas Transmission Division, the primary gas transportation system in Alberta, with 11,400 miles of pipeline and total deliveries in 1992 of 3.4 trillion ft"3. Nova also owns 50% of Foothills Pipe Lines Ltd., one of Canada's largest carriers of exported gas, and 50% of TQM Pipeline Partnership, which transports natural gas in Quebec. Nova conducts its chemicals business through Novacor Chemicals Ltd., which has plants in Alberta, Ontario, Quebec, and the USA. Novacor's major petrochemicals are methanol, ethylene, propylene, and styrene and its major plastics are polystyrene, polypropylene, and polyethylene. Nova's gas-producing branch Novalta Resources produced 26 billion ft"3 of natural gas in 1992 and has proven reserves of 334 billion ft"3. Nova's net ...

315

Micromachining using a focused ion beam miller  

International Nuclear Information System (INIS)

Full text: The focused ion beam (FIB) miller is becoming well established as a machine for the structural analysis of materials and for the rapid preparation of transmission electron microscope specimens. It has also been used for some time in the semiconducting materials industry for the analysis, repair and redesign of device materials. However, one emerging technique is the use of the FIB for micromachining. The FIB software can also be used to manufacture and machine components. This process can occur through converting software, typically in the form of bitmaps or TIF files, to proprietary 'stream' files. These files allow, often complex, patterns to be generated and milled into the specimen and thus the generation of micro-electromechanical systems. Frequently, this involves largely two-dimensional patterns and structures, however, more complex patterns and file types can be generated which allow, for example, device prototyping or the ...

2002-02-01

316

Medical image transmission via communication satellite. Evaluation of bone scintigraphy  

International Nuclear Information System (INIS)

As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and 93.2#+-#2.4% on the view box and there was no ...

317

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...

1976-05-21

318

Leveraging the power of mesh  

Energy Technology Data Exchange (ETDEWEB)

Mesh network applications are used by utilities for metering, demand response, and mobile workforce management. This presentation provided an overview of a multi-dimensional mesh application designed to offer improved scalability and higher throughput in advanced metering infrastructure (AMI) systems. Mesh applications can be used in AMI for load balancing and forecasting, as well as for distribution and transmission planning. New revenue opportunities can be realized through the application's ability to improve notification and monitoring services, and customer service communications. Mesh network security features include data encryption, data fragmentation and the automatic re-routing of data. In order to use mesh network applications, networks must have sufficient bandwidth and provide flexibility at the endpoint layer to support multiple devices from multiple vendors, as well as support multiple protocols. It was concluded that ...

2006-07-01

319

Induced current switching development work for the application of ground interrupter switches on the Hydro-Quebec H.V. system  

Energy Technology Data Exchange (ETDEWEB)

Phenomena associated with induced currents and voltages on high voltage transmission lines were discussed. Basic principles were reviewed. Action taken by Hydro-Quebec to assess the importance of associated problems on its grid was described. Hydro-Quebec`s findings and recommendations were compared with those of the International Standard, IEC 1129. It was concluded that for most cases, induced currents and voltages were higher than those listed under Class A recommendations of IEC 1129 as rated switching capabilities for ground switches assigned to this duty. For worst case scenarios, it was also found that, values of induced currents and voltages were lower than those of Class B recommendations. Hydro-Quebec and GEC Alsthom T and D collaborated to design and type test a full range of low cost and efficient ground interrupter switches tailored to Hydro-Quebec`s needs. A list of general application criteria of ground interrupter switches that evolved from that ...

1995-12-31

320

H2/Ar and vacuum annealing effect of ZnO thin films deposited by RF magnetron sputtering system  

British Library Electronic Table of Contents (United Kingdom)

The properties of ZnO films were investigated as functions of annealing temperatures in H2/Ar and vacuum. The resistivities and mobilities of ZnO films decreased with increase of annealing temperatures in vacuum and H2/Ar ambients. However, the carrier densities of ZnO films increased with increase of annealing temperatures in vacuum and H2/Ar ambients. The resistivities of ZnO2 films annealed at 300degreeC were 2186cm and 798cm in H2/Ar and vacuum ambients, respectively. The resistivities of ZnO films annealed in vacuum and H2/Ar ambients at 600degreeC were similar with 0.040cm and 0.035cm, respectively. The hydrogen donor was more dominant than the oxygen vacancy or Zn interstitial donor in ZnO films annealed in ambient H2/Ar at low temperatures. The average optical transmission was >82%...

2010-01-01

321

Electromagnetic fields and cancer: how ICNIRP has dealt with the issue  

International Nuclear Information System (INIS)

Whether exposure to electromagnetic fields (EMFs) cause cancer has been vigorously debated for many years and has been the most vexing issue with which ICNIRP has had to deal during its short existence. There have been three parts of the electromagnetic spectrum that the issue of cancer has raised: static (0 Hz) magnetic fields, extremely low frequency (ELF) fields (defined as > 0-300 Hz, but concerns have been raised almost exclusively at the power frequencies of 50/60 Hz), and radiofrequency (RF) fields (300 Hz -300 GHz). By far the major problems have arisen during the construction of new high voltage transmission lines and mobile telephone systems. Actions by protest groups concerned with possible health effects, especially with cancer in children, has now reached such a scale that it is costing electrical utilities and communications companies billions of dollars annually world-wide. With such high stakes, ICNIRP has had to be extremely ...

1996-04-01

322

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new insulator and broken insulator. A ...

1996-12-31

323

Dynamics of the changing utility world  

Energy Technology Data Exchange (ETDEWEB)

There are many factors contributing to the changes taking place within the electric utility industry. The environmental pressures on the industry are substantial and include the global warming issue, hazardous and nuclear waste challenges, air toxicities, and the electromagnetic field controversy. An issue of special concern is deregulation of the industry, which brought with it retail wheeling, wholesale wheeling, transmission access, and market-based pricing, all of which have greatly shaken the industry. The changes are expected to happen quickly. This is quite different from the 31 years it took to deregulate the telecommunications industry, the 15 to 20 years for railroads, the 9 years for the natural gas industry, and the 2 years for the airline industry. Historically there has been a general willingness among the utilites to share information through collaborative research. Research and development is viewed as a cost and not an investment in the electric ...

1996-01-01

324

Design of electron beam accelerators for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. Alternatively, a low voltage PFN ...

1988-07-01

325

Design of electron beam accelerator for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. Alternatively, a low voltage PFN followed ...

1988-01-01

326

Depth dependence of defect evolution and TED during annealing  

Energy Technology Data Exchange (ETDEWEB)

A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si{sup +} implant conditions have been considered. TEM analysis for the highest energy/dose shows that {l_brace}1 1 3{r_brace} defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, {l_brace}1 1 3{r_brace} defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical models to simulate ...

2004-02-01

327

Depth dependence of defect evolution and TED during annealing  

International Nuclear Information System (INIS)

A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si"+ implant conditions have been considered. TEM analysis for the highest energy/dose shows that #left brace#1 1 3#right brace# defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, #left brace#1 1 3#right brace# defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical models to ...

2004-02-01

328

Conference on reformation of regulation in OECD/IEA power sector - Conference on reformation of regulation in USA, Netherlands, Japan  

Energy Technology Data Exchange (ETDEWEB)

Since 1995, OECD started to examine the current situation of government regulation in each member country and discussed to recommend quality improvement of regulation to member countries. The conference on reformation of regulation in power industry was held in October and December 1998. In USA, enhancing competition in supplying electricity was recommended by eliminating differentiation in use of power network, transmission network and incidental facilities. The retail competition is also an important reformation. The reformation in Netherlands can be seen as following EU guide for revealing problems of the existing regulation in the power industry and for opening up a power market. The Dutch government passed the power act for opening up a market to the public between 1999 and 2007. In Japan, the entry of independent power provider (IPP) has been softened. With the opening of bid system in 1999, bids will be equally given to both power ...

1999-01-01

329

Comparative study of phase stability and film morphology in thin-film M/GaAs systems (M = Co, Rh, Ir, Ni, Pd, and Pt)  

Energy Technology Data Exchange (ETDEWEB)

To attain reproducible and stable contacts to compound semiconductor devices, it is necessary to achieve thermodynamically stable phases after the reaction of metals with the compound semiconductor. In this study, the final phases produced by the reactions between GaAs and thin metal films of Co, Rh, Ir, Ni, Pd, and Pt have been investigated. They are identified as MGa for M = Co, Rh, Ni, Pd, and Pt, monoarsenides of Co and Ni, diarsenides of Rh, Ir, Pd, and Pt, and Ir/sub 3/Ga/sub 5/. These phases, if deposited directly onto GaAs, will produce thermally stable contacts. In addition to the identification of these stable phases, analyses of the products of thin-film M/GaAs reactions by transmission electron microscopy, x-ray diffraction, and Rutherford backscattering spectrometry reveal the distribution, grain size, and crystallographic texture of these end phases. Trends in these observations across the six metal/GaAs reactions studied are explained by considering ...

1987-09-01

330

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their location regular maintenance coatings are also not feasible. ...

1999-11-22

331

Adsorption based processes as alternative to common gas conditioning at underground storage facilities using Sorbead; Procedes bases sur l'adsorption comme solution de rechange dans le conditionnement du gaz dans des lieux de stockage souterrains a l'aide de Sorbead  

Energy Technology Data Exchange (ETDEWEB)

The European gas market is continuing to expand due to increased industrial, domestic and power generation demand. As a result of this demand, and the trend toward liberalization of the market, the need for storage of gas is also increasing. One key segment of the large scale storage of gas is underground storage, either in partially depleted gas or oil fields, naturally occurring caverns, aquifers and salt cavities. In most cases the gas produced after storage requires conditioning to meet the water of hydrocarbon dew point specification of the gas transmission system. For that reason export gas from storage will require gas conditioning in order to meet pipeline specifications. Adsorption as a feasible and reliable process will be presented in detail and especially in regards to hydrocarbon dew-pointing compared with other process options. (author)

2000-07-01

332

The value of distributed generation: The PVUSA grid-support project serving Kerman Substation. Interim report, April 1994  

Energy Technology Data Exchange (ETDEWEB)

A common practice of electric utilities experiencing transmission and distribution (T and D) system overloads is to expand the substation, add lines, or upgrade equipment, all of which are capital intensive options. In 1988, it was hypothesized that strategically sited photovoltaics (PV) could benefit parts of T and D systems near or at overloaded conditions. An evaluation methodology was developed and applied to a test case (Kerman Substation near Fresno, California). Analytical results suggested that the value of PV to the T and D system could substantially exceed its energy and generation capacity value. The importance of this finding indicated the need for empirical validation. This led to the construction of a 0.5 MW PV demonstration plant by Pacific Gas and Electric Company (PG and E) at Kerman, California as part of the PVUSA (PV for Utility Scale Applications) project. PVUSA is a national ...

1994-07-01

333

A15 superconductors through direct solid-state precipitation: V/sub 3/Ga and Nb/sub 3/Al  

Energy Technology Data Exchange (ETDEWEB)

A solid-state precipitation process was used to prepare superconducting tapes containing an A15 phase, V/sub 3/Ga or Nb/sub 3/Al, in a ductile niobium or vanadium containing BCC matrix. Ingots weighing as large as 30 to 50 gms of V-(14 approx. 19 at. %) Ga and Nb-(13 approx. 22 at. %) Al were prepared by arc-melting, homogenized, quenched, warm-rolled over 99% into tape, and aged at temperatures in the range 600/sup 0/C to 1000/sup 0/C to precipitate the superconducting A15 phase. The features demonstrated by the process are very attractive for practical applications. In the V-Ga system, transmission electron microscopy (TEM) studies revealed the A15 precipitates in an elongated form. However, for the Nb-Al samples, deformed and aged at 750/sup 0/C, TEM studies revealed A15 precipitation in fine equi-axed particles which formed as a semi-continuous network over sub-grain boundaries formed by the recovery of deformation-induced dislocations. In ...

1980-09-01

334

Optical and electrochemical properties of CeO[sub 2] and CeO[sub 2]-TiO[sub 2] coatings  

Energy Technology Data Exchange (ETDEWEB)

Thin solid films of CeO[sub 2] and mixed CeO[sub 2]-TiO[sub 2] were prepared by the sol-gel route via the dip-coating technique. Particulate sols of ceria were made from inorganic ((NH[sub 4])[sub 2]Ce(NO[sub 3])[sub 6]) precursor which were used for preparation of CeO[sub 2] thin solid films while CeO[sub 2]-TiO[sub 2] coatings have been made by using mixed organic-inorganic (Ti(OiPr)[sub 4] and CeCl[sub 3].7H[sub 2]O) precursors. The solar transmission values (T[sub s]) of both coatings are in the range 0.6-0.8 and depend on coating thickness. Cyclic voltammetric (CV) measurements show that the CeO[sub 2]/LiOH system exhibits higher overall electrochemical reversibility when compared to the CeO[sub 2]-TiO[sub 2]/LiOH system. The CeO[sub 2]/LiOH system is also less sensitive with regard to the coating thickness. Coulometric measurements show that CeO[sub 2] exhibits a larger storage capability which ...

1993-11-01

335

Environmental data for sites in the national solar data network  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy's National Solar Data Program established solar energy systems in residential and commercial buildings across the United States. These solar sites are linked to Vitro Laboratories Division's computer in the National Solar Data Network (NSDN). Vitro collects and analyzes data from this network to determine the thermal performance of each of the solar systems. The network consists of: (1) sensors which measure key performance parameters at a selected site; (2) a Site Data Acquisition Subsystem (SDAS); (3) telephone transmission circuits; and (4) a Central Data Processing System (CDPS). For the majority of parameters, raw data is collected approximately every five minutes. Solar insolation and certain other parameters, which are subject to rapid variance, are sampled every 32 seconds. Environmental information collected at the sites for the reporting month are ...

1980-07-01

336

APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs  

Energy Technology Data Exchange (ETDEWEB)

A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified nuclide. The APSTNG also ...

1992-07-01

337

Electrical human-power transmission. The bicycle technology of the 21st century; Elektrische Muskelkrafttransmission. Fahrradtechnologie des 21. Jahrhunderts. Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Since 1994-95 the University of Applied Sciences Berne is working on weather-proof electric bicycles. The main drawbacks of bicycles, no weather-protection, little comfort of the saddle, the difficulty of climbing hills, are to be eliminated. The electro-mechanical drive-train of 'Ultraleichtmobil ULM BE 2000', developed in 1995-96, was mechanically complicated. This resulted in reduced energy-efficiency and intense maintenance. Too, the drive-train was expensive in production. A fully electrical human-power transmission seemed to be the solution to the problems mentioned above. It is appealing not only to the user of the vehicle, but also to the producer and to the persons doing the maintenance. Following an internal study showing the technical feasibility of such an electrical transmission, a controllable DC/DC-converter which allows to operate a pedal-driven generator at maximum efficiency has been developed. The electrical ...

1999-12-01

338

Predicting formula development of audible noise on a 765 kV AC transmission line 1  

Energy Technology Data Exchange (ETDEWEB)

Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500 kV and above. Therefore this paper describes audible noise characteristics of 6 X 480 mm{sup 2} conductor bundle in KEPRI 765 kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765 kV Transmission Line was developed using this results. (author). 4 refs., 4 figs., 4 tabs.

1996-04-01

339

New approach to compensation of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided design procedure has been developed for the series compensation of an extra high voltage line with a compensating network connected at one or the other end or both ends. Higher degree polynomial equations are derived in terms of compensating elements to compute the network parameters for optimum received power with constrained capacitor terminal voltage, safe line current, Ferranti voltage and transient stability. It is shown that series capacitors located at both ends provide the most effective means from the viewpoint of power transmission capability in either direction, transmission efficiency and series capacitor rating in comparison with a capacitor located at one or the other end.

1985-09-01

340

Environmental concerns for high-voltage transmission lines in UNIPEDE countries  

Energy Technology Data Exchange (ETDEWEB)

High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d`Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.

1996-11-01

341

Environmental concerns for high-voltage transmission lines in UNIPEDE countries  

International Nuclear Information System (INIS)

High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d'Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.

1996-01-01

342

Electric field exposure from electric blankets  

Energy Technology Data Exchange (ETDEWEB)

Comparisons of the 60 Hz electric field exposures associated with high voltage transmission lines to those associated with common household sources can provide an important input to regulatory decisions that involve transmission line fields. Electric blankets are of interest in this context because the exposures they produce are among the most intense and prolonged of any of the household sources of 60 Hz electric field exposure. This paper presents a theoretical analysis of the body surface fields induced by electric blankets. Electric blanket exposure intensities are compared to those associated with transmission lines.

1987-04-01

343

Terms Beginning With \\  

Wastenet

... Microwaves, radio waves, and low-frequency electromagnetic fields from high-voltage transmission lines . Non-Methane Hydrocarbon (NMHC): The sum of all hydrocarbon air ...

345

Residential proximity to high voltage transmission lines and depressive symptomatology  

Energy Technology Data Exchange (ETDEWEB)

A number of epidemiological studies indicate an association between depression and proximity to high voltage transmission lines. These studies have been criticized, however, for using surrogate measures of electromagnetic fields (EMFs) and unstandardized measures of depression. In an effort to overcome these limitations, the Center for Epidemiological Studies Depression (CES-D) scale was administered to 152 women living either adjacent to a transmission line or one block away. Results indicate that homes adjacent to the transmission lines have an average EMF level of 4.86 milligauss at their front door and those one block away have an average of 0.68 milligauss. There was no significant difference in CES-D scores between the groups, controlling for demographic variables. There appeared to be an increase in other health effects, including cancer and miscarriages, but these findings were preliminary and need further ...

1992-01-01

346

Opportunistic Cooperation in Cognitive Femtocell Networks  

CERN Document Server

We investigate opportunistic cooperation between unlicensed secondary users and legacy primary users in a cognitive radio network. Specifically, we consider a model of a cognitive network where a secondary user can cooperatively transmit with the primary user in order to improve the latter's effective transmission rate. In return, the secondary user gets more opportunities for transmitting its own data when the primary user is idle. This kind of interaction between the primary and secondary users is different from the traditional dynamic spectrum access model in which the secondary users try to avoid interfering with the primary users while seeking transmission opportunities on vacant primary channels. In our model, the secondary users need to balance the desire to cooperate more (to create more transmission opportunities) with the need for maintaining sufficient energy levels for their own ...

2011-01-01

347

Nutating Mechanical Transmission (Maroth Drive Principle)  

Science.gov (United States)

... d Diameter of ro.'ling element of a cylindrical roller bearing ... L Life (B-10) of a cyl.ndrical roller bearing LACA Contact ratio ...

1974-01-01

348

NASA - Hurricane Season 2008: Hurricane Ike (Atlantic Ocean)  

Science.gov (United States)

The company reports that with the help of outside companies, they completed all major fixes including high-voltage transmission lines to neighborhood ...

349

Microscopic-Observation Drug-Susceptibility Assay for the Diagnosis of TB  

UK PubMed Central (United Kingdom)

BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available

2006-10-12

350

Malaria transmission in two localities in north-western Argentina  

UK PubMed Central (United Kingdom)

BackgroundMalaria is one of the most important tropical diseases that affects people globally. The influence of environmental conditions in the patterns of temporal distribution...Full Text Available

351

Interaction of legionella pneumophila and helicobacter pylori with bacterial species isolated from drinking water biofilms  

UK PubMed Central (United Kingdom)

BackgroundIt is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission...Full Text Available

353

Documentation of Contact Precautions in an Electronic Health Record  

UK PubMed Central (United Kingdom)

Contact precautions are implemented to reduce transmission of multidrug-resistant organisms but may also increase hospital costs and patient complications. The goal of this study was to determine...Full Text Available

2011-07-01

354

Do pediatric emergency departments pose a risk of infection?  

UK PubMed Central (United Kingdom)

BackgroundThere is no data documenting the existence of a risk of infection transmission in ambulatory healthcare settings but concern remains. Our objective was to determine the...Full Text Available

355

Computer Controlled MHD Power Consolidation and Pulse ...  

Science.gov (United States)

... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...

1990-08-01

356

Cholinergic modulation of multivesicular release regulates striatal synaptic potency and integration  

UK PubMed Central (United Kingdom)

The pleiotropic actions of neuromodulators on pre- and postsynaptic targets present challenges to disentangling the mechanisms underlying regulation of synaptic transmission. Within the striatum,...Full Text Available

2009-09-01

357

Capturing energy in the air to power electronics | SmartPlanet  

Wastenet

...smart grid applications where you could place them very close to the high-voltage transmission lines , very close to transformers and so on. Photo:...

358

Airborne minerals and related aerosol particles: Effects on climate and the environment  

UK PubMed Central (United Kingdom)

Aerosol particles are ubiquitous in the troposphere and exert an important influence on global climate and the environment. They affect climate through scattering, transmission, and absorption of...Full Text Available

1999-03-30

359

Variations in humanized and defined culture conditions supporting derivation of new human embryonic stem cell lines  

DEFF Research Database (Denmark)

The evolution of "humanized" (i.e., free of animal sourced reagents) and ultimately chemically defined culture systems for human embryo stem cell (hESC) isolation and culture is of importance to improving their efficacy and safety in research and therapeutic applications. This can be achieved by integration of a multitude of individual approaches to replace or eliminate specific animal sourced reagents into a single comprehensive protocol. In the present study our objective was to integrate strategies obviating reliance on some of the most poorly defined and path-critical factors associated with hESC derivation, namely the use of animal immune compliment to isolate embryo inner cell mass, and animal sourced serum products and feeder cells to sustain hESC growth and attachment. As a result we report the derivation of six new hESC lines isolated by outgrowth from whole blastocysts on an extracellular matrix substrate of purified human laminin (Ln) with transitional ...

2006-01-01

360

The enhanced genomic instability was induced by alpha particle and low-energy ion irradiation in somatic cells of Arabidopsis thaliana  

International Nuclear Information System (INIS)

Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. The local alpha particle irradiation of root was performed. Result exhibited ...

2008-08-12

361

Study of implantation damage in germanium formed using Ga"+ FIB  

International Nuclear Information System (INIS)

Full text: It is known that the ion implantation of germanium single crystals at room temperature results in drastic alteration of the germanium surface and the formation of cellular relief. Voids were found into the near-surface damage layer. The intersection of these voids with the germanium surface, as result of sputter etching, forms cellular relief. However, exact mechanism responsible for formation of the voids is not known. A 10 and 30 keV Ga"+ irradiation of Ge #left brace#100#right brace# crystal at room temperature was carried out using a focused ion beam (FIB) system with a dose in the range 0.5x10"1"2 to 1.5x10"1"4 ion/cm"2. The topology of the modified germanium surface and the structure of the radiation damage was studied using imaging facilities of the FIB systems and transmission electron microscopy. The strong cellular structure of Ge was observed after an ion dose of 3x10"1"3 ion/cm"2. High-resolution TEM ...

362

Solid-state amorphization reaction in mechanically deformed Al_xHf_1_0_0_-_x multilayered composite powders and the effect of annealing  

International Nuclear Information System (INIS)

Single phase amorphous Al_xHf_1_0_0_-_x alloys with a wide amorphization range (33#<=#x#<=#75) were synthesized by the solid-state interdiffusion of pure polycrystalline Al and Hf powders at room temperature using a rod-milling technique. The mechanisms of metallic glass formation and competing crystallization processes in the mechanically deformed composite powders were investigated by means of X-ray diffraction, differential thermal analysis, scanning electron microscopy and transmission electron microscopy. The numerous intimate layered composite particles of the diffusion couples that formed during the first and intermediate stages of milling (0-173 ks) are intermixed to form amorphous phase(s) upon heating to about 980 K by so-called thermally assisted solid-state amorphization (TASSA). The amorphization heat formation for the binary Al_xHf_1_0_0_-_x system via TASSA, #DELTA#H"T"A"S"S"A_a, was measured directly as a function of the ...

1999-03-04

363

Sizes, graphitic structures and fractal geometry of light-duty diesel engine particulates.  

Energy Technology Data Exchange (ETDEWEB)

The particulate matter of a light-duty diesel engine was characterized in its morphology, sizes, internal microstructures, and fractal geometry. A thermophoretic sampling system was employed to collect particulates directly from the exhaust manifold of a 1.7-liter turbocharged common-rail direct-injection diesel engine. The particulate samples collected at various engine-operating conditions were then analyzed by using a high-resolution transmission electron microscope (TEM) and an image processing/data acquisition system. Results showed that mean primary particle diameters (dp), and radii of gyration (Rg), ranged from 19.4 nm to 32.5 nm and 77.4 nm to 134.1 nm, respectively, through the entire engine-operating conditions of 675 rpm (idling) to 4000 rpm and 0% to 100% loads. It was also revealed that the other important parameters sensitive to the particulate formation, such as exhaust-gas recirculation (EGR) rate, ...

2003-01-01

364

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and ...

2006-01-01

365

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The acoustic amplitude ...

366

Enterprise energy management : Part 1  

Energy Technology Data Exchange (ETDEWEB)

The needs of large industrial, commercial, and institutional energy consumers are more closely connected with the needs of power utilities and energy services companies, a result of the evolving global energy environment. Consumer choice, competition amongst energy suppliers, and increased demand are brought about in some regions by deregulation. Increasingly, large energy consumers expect high levels of quality and reliability from the energy delivered. As a result, management of the cost and the quality of the energy product and the energy assets that produce, deliver, control and consume it requires different strategies. Three major challenges must be overcome: (1) requirement to support economic and efficient delivery, purchasing and use of energy, (2) requirement to guarantee higher levels of power quality and reliability, and (3) requirement to supply the growing demand for energy while establishing a market-based pricing system. The solution is the ...

2001-09-01

367

Energy Conversion and Storage Program. 1990 annual report  

Energy Technology Data Exchange (ETDEWEB)

The Energy Conversion and Storage Program applies chemistry and materials science principles to solve problems in (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes, and (5) application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to develop advanced power systems for electric vehicle and stationary energy storage applications. Topics include identification of new electrochemical couples for advanced rechargeable batteries, improvements in battery and fuel-cell materials, and the establishment of engineering principles applicable ...

1992-03-01

368

Energy Conversion and Storage Program  

Energy Technology Data Exchange (ETDEWEB)

The Energy Conversion and Storage Program applies chemistry and materials science principles to solve problems in (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes, and (5) application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to develop advanced power systems for electric vehicle and stationary energy storage applications. Topics include identification of new electrochemical couples for advanced rechargeable batteries, improvements in battery and fuel-cell materials, and the establishment of engineering principles applicable ...

1992-03-01

369

China: output grows with modernization  

Science.gov (United States)

In 1978, China's coal mining industry achieved an output of 618,000,000 metric tons of raw hard coal, an increase of 128,000,000 tons compared with 1977. This has been achieved primarily by increased new mine development and the modernizaion and expansion of existing mines. While 96% of China's coal is currently produced from underground mines, only 33% of this output is from full mechanized operations, i.e., mechanized longwall retreat faces. Over 1% is produced by hydraulic mining. The current Ten-Year Plan (1975-1985) established that the major thrust of new development and activity should be made particularly in the Shandong, Anhui, Henan, Guizhou, and Yunnan provinces. China is presently concentrating on the construction/enlargement of eight major coal mining centers, mainly in the north and northeast of the country, each with a designed capacity in excess of 10,000,000 tons a year. China has elected to import large quantities of mining machinery and equipment, ...

1979-11-01

370

Power control for wind turbines in weak grids: Concepts development  

Energy Technology Data Exchange (ETDEWEB)

Presently, high wind potentials in remote areas may not be utilized for electricity production due to limited grid transmission capacity and/or difficulties in matching the electricity production with the demand. The overall project objective is to help overcome these bottlenecks, i.e. to identify and analyze methods and technologies for making it viable to utilize more of the wind potential in remote areas. The suggestion is to develop a power control concept for wind turbines which will even out the power fluctuations and make it possible to increase the wind energy penetration. The main options are to combine wind power with a pumped hydro power storage or with an AC/DC converter and battery storage. The AC/DC converter can either be an `add-on` type or it can be designed as an integrated part of a variable speed wind turbine. The idea is that combining wind power with the power control concept will make wind power more firm and possible to connect to weaker ...

1999-03-01

371

Field driven ferromagnetic phase evolution originating from the domain boundaries in antiferromagnetically coupled perpendicular anitsotropy films  

Energy Technology Data Exchange (ETDEWEB)

Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically coupled perpendicular anisotropy films. MXTM ...

2008-05-01

372

The effects of high voltage transmission lines on the health of adjacent resident populations  

Energy Technology Data Exchange (ETDEWEB)

A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant or consistent relationships between exposure to a high voltage DC power line and the perceived health problems that were measured. The sample was not, however, large enough to draw statistically significant conclusions regarding possible health effects with a very low incidence.

1984-01-01

373

Principles of ground relaying for high voltage and extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper is a tutorial discussion of the basic principles of ground relaying for high voltage and extra high voltage transmission lines. Three different HV configurations are considered: Long lines, lines with a weak mid-point station, and mutually-coupled lines. Application criteria for EHV circuits are also discussed, and specific setting calculations are included where appropriate.

1983-02-01

374

PRO2000 vaginal gel for prevention of HIV-1 infection (Microbicides Development Programme 301): a phase 3, randomised, double-blind, parallel-group trial  

UK PubMed Central (United Kingdom)

SummaryBackgroundInnovative prevention strategies for HIV-1 transmission are urgently needed. PRO2000 vaginal gel was efficacious against HIV-1 transmission in studies...Full Text Available

2010-10-16

375

Now try to explain network security  

Science.gov (United States)

Overloaded transmission lines are only part of the problem. The ability of the network to carry power is also limited by the supply of reactive power and by frequency stability. Reactive power problems must be corrected in minutes, frequency stability problems in seconds. There is no way that market forces can handle these problems. Reactive power must be supplied to all long transmission and distribution lines to compensate for the loss of reactive volt-amperes - and resulting voltage drop - in the reactance along the line`s length. 7 figs.

1996-10-01

376

Negative ion formation in magnetically insulated transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.

1982-05-01

377

MCNPX analysis of 68 MeV neutron transmission on iron  

Energy Technology Data Exchange (ETDEWEB)

A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.

1999-02-01

378

Identification and characterization of populations living near high-voltage transmission lines: a pilot study.  

UK PubMed Central (United Kingdom)

Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 microT, and sometimes over 2 microT. Yet, populations studied in most epidemiologic...Full Text Available

1993-12-01

379

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

380

Fuel ignition by high voltage capacitive discharges  

Energy Technology Data Exchange (ETDEWEB)

The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmission lines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmission lines.

1983-03-01

381

Fractal dimension determination of sol-gel powders using transmission electron microscopy images  

Energy Technology Data Exchange (ETDEWEB)

SiO{sub 2}, TiO{sub 2} and AlO(OH) powders obtained by the sol-gel method were investigated by transmission electron microscopy. The mass-radius relation was used to determine the fractal dimensions from the images. These fractal dimensions were corrected in order to obtain the powder fractal dimensions. The results indicate a good fractal behavior and high fractal dimensions.

2004-09-15

382

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

International Nuclear Information System (INIS)

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the ...

1999-05-01

383

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the ...

1995-05-01

384

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-12-31

385

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

International Nuclear Information System (INIS)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-08-24

386

Aspects of landscaping in case of constructing new HV transmission line. Landschaftsschutzaspekte beim Bau einer neuen Hochspannungsleitung  

Energy Technology Data Exchange (ETDEWEB)

When constructing new high-voltage transmission lines landscape aspects play a more and more important role. The project described is particularly interesting as it demonstrates that it is possible to find acceptable solutions for everyone if all partners are prepared to make concessions. The article also describes a new concept for the connection of concrete tower elements. (orig.).

1991-01-23

387

Analysis of microstructure of materials using a combination of a focused ion beam and transmission electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

Recent development in application of a focused ion beam (FIB) technique to preparation of thin foil specimens for transmission electron microscopy (TEM) observation has been reviewed. Combined technique of FIB/TEM enables one to analyze those microstructures which have been almost impossible or very difficult to analyze so far. (author)

2002-03-01

388

Altered GABAA receptor-mediated synaptic transmission disrupts the firing of gonadotropin-releasing hormone neurons in male mice under conditions that mimic steroid abuse  

UK PubMed Central (United Kingdom)

Gonadotropin–releasing hormone (GnRH) neurons are the central regulators of reproduction. GABAergic transmission plays a critical role in pubertal activation of pulsatile GnRH secretion....Full Text Available

2010-05-12

389

Active RF filter for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.

1993-07-01

390

A fuzzy logic based fault classification approach using current samples only  

Energy Technology Data Exchange (ETDEWEB)

An approach for classification of transmission line faults is presented. The approach is based on fuzzy logic and requires the consideration of the samples of three phase currents at one end of transmission line. To illustrate the effectiveness of the proposed approach extensive simulation studies, using EMTP and MATLAB, have been carried out for different types of fault considering wide variations in the operating conditions. (author)

2007-04-15

391

A comparison of methods for calculating audible noise of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.

1982-10-01

392

Groundwater travel time uncertainty analysis. Sensitivity of results to model geometry, and correlations and cross correlations among input parameters  

Energy Technology Data Exchange (ETDEWEB)

This study examines the sensitivity of the travel time distribution predicted by a reference case model to (1) scale of representation of the model parameters, (2) size of the model domain, (3) correlation range of log-transmissivity, and (4) cross correlations between transmissivity and effective thickness. The basis for the reference model is the preliminary stochastic travel time model previously documented by the Basalt Waste Isolation Project. Results of this study show the following. The variability of the predicted travel times can be adequately represented when the ratio between the size of the zones used to represent the model parameters and the log-transmissivity correlation range is less than about one-fifth. The size of the model domain and the types of boundary conditions can have a strong impact on the distribution of travel times. Longer log-transmissivity correlation ranges cause larger ...

1985-03-01

394

Properties and performance of new metastable Ti-B-C-N hard coatings prepared by magnetron sputtering  

Energy Technology Data Exchange (ETDEWEB)

Thin films of new metastable materials from the system Ti-B-C-N were deposited on metallic substrates by d.c. magnetron sputtering in different Ar+N{sub 2} atmospheres. The multiphase compound targets used were based on various compositions on the TiC-TiB{sub 2} and TiB{sub 2}-C tie lines of the Ti-B-C phase diagram. The structure and chemical composition of the films were characterized by electron microprobe analysis, depth profiling Auger electron spectroscopy, X-ray diffraction and transmission electron microscopy. The hardness, critical load of failure and the tribological behavior of the coatings were investigated. Superhard single-phase crystalline metastable Ti-B-C-N layers with hardness values exceeding 5000 HV{sub 0.05} and extremely low sliding wear against 100Cr6 and Al{sub 2}O{sub 3} counterparts could be produced by reactive sputtering of various TiC-TiB{sub 2} targets in Ar+N{sub 2} atmospheres with low nitrogen flows. In the case ...

1995-10-01

395

7. Kassel symposium on energy systems technology: Renewable energy sources and efficient utilization of energy; 7. Kasseler Symposium Energie-Systemtechnik: Erneuerbare Energien und rationelle Energieverwendung  

Energy Technology Data Exchange (ETDEWEB)

This proceedings volume comprises 17 papers on the following subjects: Methane hydrates, compounds of gas and water; Compressed air stroage gas turbine power plants / Scheduled application for load levelling between varying wind power production and power demand; Modern pumped storage power stations in the GW range - the PSW Goldisthal example; Lead batteries - new developments and future applications; Alkaline battery systems for hybrid electric road vehicles; Lighium systems and their applications; Zinc/air cells; Hydrogen storage - metal hydride storage, compressed gas storage, LNG storage; Carbon nanofibres for hydrogen storage; Double-layer condensers - technology, cost, perslpectives; Supercondensers in motor vehicles; Superconducting magnetic energy stores; Flywheel storage - status report; Decentralized energy storage in the European integrated supply grid - the EU project DISPOWER; Intercontinental integration of power supply - ...

2002-07-01

396

Sound transmission loss of composite sandwich panels  

Science.gov (United States)

Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and ...

2009-01-01

397

The neutron capture cross sections of {sup 237}Np(n,{gamma}) and {sup 240}Pu(n,{gamma}) and its relevance in the transmutation of nuclear waste  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF {sigma}(n,{gamma}) agrees within uncertainties with JENDL-3.3 and ...

2008-07-01

398

The neuronal nicotinic acetylcholine receptor {alpha}7 subunit gene: Cloning, mapping, structure, and targeting in mouse  

Energy Technology Data Exchange (ETDEWEB)

The neuronal nicotinic acetylcholine receptor {alpha}7 subunit is a member of a family of ligand-gated ion channels, and is the only subunit know to bind {alpha}-bungarotoxin in mammalian brain. {alpha}-Bungarotoxin binding sites are known to be more abundant in the hippocampus of mouse strains that are particularly sensitive to nicotine-induced seizures. The {alpha}7 receptor is highly permeable to calcium, which could suggest a role in synaptic plasticity in the nervous system. Auditory gating deficiency, an abnormal response to a second auditory stimulus, is characteristic of schizophrenia. Mouse strains that exhibit a similar gating deficit have reduced hippocampal expression of the {alpha}7 subunit. We have cloned and sequenced the full length cDNA for the mouse {alpha}7 gene (Acra-7) and characterized its gene structure. The murine {alpha}7 shares amino acid identity of 99% and 93% with the rat and human {alpha}7 subunits, respectively. Using an interspecies ...

1994-09-01

399

Synthesis of colloidal silver iron oxide nanoparticles--study of their optical and magnetic behavior.  

Science.gov (United States)

Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements reveal an interesting ...

2009-07-01

400

Optical Properties and Wave Propagation in Semiconductor-Based Two-Dimensional Photonic Crystals  

Energy Technology Data Exchange (ETDEWEB)

This work is a theoretical investigation on the physical properties of semiconductor-based two-dimensional photonic crystals, in particular for what concerns systems embedded in planar dielectric waveguides (GaAs/AlGaAs, GaInAsP/InP heterostructures, and self-standing membranes) or based on macro-porous silicon. The photonic-band structure of photonic crystals and photonic-crystal slabs is numerically computed and the associated light-line problem is discussed, which points to the issue of intrinsic out-of-lane diffraction losses for the photonic bands lying above the light line. The photonic states are then classified by the group theory formalism: each mode is related to an irreducible representation of the corresponding small point group. The optical properties are investigated by means of the scattering matrix method, which numerically implements a variable-angle-reflectance experiment; comparison with experiments is also provided. The analysis of surface ...

2002-12-31

401

Microstructural analysis of as-processed U-10 wt.%Mo monolithic fuel plate in AA6061 matrix with Zr diffusion barrier  

International Nuclear Information System (INIS)

For higher U-loading in low-enriched U-10 wt.%Mo fuels, monolithic fuel plate clad in AA6061 is being developed as a part of Reduced Enrichment for Research and Test Reactor (RERTR) program. This paper reports the first characterization results from a monolithic U-10 wt.%Mo fuel plate with a Zr diffusion barrier that was fabricated as part of a plate fabrication campaign for irradiation testing in the Advanced Test Reactor (ATR). Both scanning and transmission electron microscopy (SEM and TEM) were employed for analysis. At the interface between the Zr barrier and U-10 wt.%Mo, going from Zr to U(Mo), UZr_2, #gamma#-UZr, Zr solid-solution and Mo_2Zr phases were observed. The interface between AA6061 cladding and Zr barrier plate consisted of four layers, going from Al to Zr, (Al, Si)_2Zr, (Al, Si)Zr_3 (Al, Si)_3Zr, and AlSi_4Zr_5. Irradiation behavior of these intermetallic phases is discussed based on their constituents. Characterization of as-fabricated phase ...

2010-07-01

402

Methods for evaluating long-term changes in thermal resistance of vacuum insulation panels  

Energy Technology Data Exchange (ETDEWEB)

Vacuum insulation panels (VIP) offer excellent thermal resistance properties that can enhance the energy efficiency of insulating systems, save space and contribute to energy consumption reductions. However, VIPs are not used much in Canada, and new commitments to carbon dioxide reductions has created the need to study the prospect of using VIPs in various components of a building envelope. For that reason, assessment methods for the applicability and sustainability of VIPs for use in building envelope construction were developed. There are practical aspects regarding the long-term performance and application of VIPs in building construction. Air molecules and water molecules can permeate through the foil and seams of the VIPs, causing a reduction in thermal resistance. This paper addresses some of the test methods that may accelerate long term changes in thermal resistance. Results were presented from tests using elevated pressure, relative humidity and ...

2005-07-01

403

Manipulation of the loading and size of zero-valent iron nanoparticles immobilized in electrospun polymer nanofibers.  

Science.gov (United States)

A simple approach to controlling the loading percentage and size of zero-valent iron nanoparticles (ZVI NPs) immobilized within polyacrylic acid (PAA)/polyvinyl alcohol (PVA) nanofibrous mats for dye remediation applications is described. A functional "nanoreactor" comprised by electrospun PAA/PVA nanofibers served to bind ferric ions with the carboxyl groups of PAA, prior to their reduction to ZVI NPs. The resulting ZVI NP-immobilized hybrid polymer nanofibers were characterized using scanning electron microscopy, transmission electron microscopy, and thermogravimetric analysis. The morphology of the polymer nanofibers exhibited no appreciable change even after eight cycles of ferric ion binding/reduction, and the loading percentage and size of the ZVI NPs were controlled simply by varying the number of ferric ion binding/reduction cycles. Dye remediation experiments revealed that the decoloration effect of ZVI NPs immobilized within the polymer nanofibers is both ...

2011-06-01

404

Large sample NAA facility at GRR-1 research reactor: Design and applications  

International Nuclear Information System (INIS)

Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of large sample analysis of non-homogeneous ...

2003-06-09

405

Investigating the formation mechanism of soot-like materials present in blast furnace coke samples  

Science.gov (United States)

An attempt to gain an understanding of the formation mechanism of these 'soot-like' materials has been made by means of tracing the changes in the molecular-mass distribution and molecular structure of the NMP-extractable materials from an injectant coal as well as its partially gasified chars and its pyrolytic tars. Variations in the SEC chromatograms provide clues about changes in the apparent molecular-mass distributions of these NMP extracts. Results suggest that the build-up of 'soot-like' materials follows from the secondary reactions of tars evolved from the injectant coal. The likely secondary-reaction pathways have been probed by collating structural information on these NMP extracts. The time-resolved 13-16 and 22-25 min elution fractions from the SEC column have been characterized using UV fluorescence (UV F) spectroscopy. Greater concentrations of larger aromatic ring systems are found present in samples formed under ...

2008-09-15

406

Humidity impact on the thermal insulation in case of higher insulation levels; Feuchteeinfluesse auf den praktischen Waermeschutz bei erhoehtem Daemmniveau  

Energy Technology Data Exchange (ETDEWEB)

The article deals with the problem of a humidity addition to thermal conductivity, diffusion and latent heat effects in heat transfer through building components. It shows with examples humidity effects for exterior walls with core insulation, with composite insulation system as well as for insulated roof membrane assemblies. From these it can be summarized that - sorption humidity is for today`s construction conditions (good thermal insulation and humidity protection) a suitable reference quantity for the determination of practice-oriented, substance-specific and physically correct humidity additions to the thermal conductivity of hygroscopic components; - diffusion and latent heat effects are in case of good rain imperviousness and low water absorbing capacity of the exterior component layers of secondary importance for transmission heat losses; - an increase in insulating layer thickness in order to improve the thermal insulation is possible ...

1994-12-31

407

Heat management - a technique for resolving the conflicting aims between fuel consumption and comfort; Waermemanagement - ein Werkzeug zur Loesung der Zielkonflikte zwischen Verbrauch und Komfort  

Energy Technology Data Exchange (ETDEWEB)

In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are developed, and the advantages are presented in detail. [German] Abgeleitet aus den Trends in der Fahrzeugentwicklung wird auf den immer staerker werdenden ...

1999-07-01

408

Guidelines for the use of structural reliability and risk based techniques to justify the operation of onshore pipelines at design factors greater than 0.72; Directives concernant l'emploi des techniques de risque/fiabilite structurels afin de justifier l'exploitation de gazoducs terrestres a des coefficients de securite superieurs a 0,72  

Energy Technology Data Exchange (ETDEWEB)

Structural reliability and risk based techniques have recently been used to demonstrate safe operation of high-pressure pipelines at design factors greater than 0.72. In particular several pipelines are now operating on the Transco National Transmission System, in the UK, at design factors of 0.78 owing to the use of the techniques. The overall structural reliability and risk based approach for justifying safe operation of pipelines at these stress levels is thus now established. However, in order to establish cost effective and viable widespread use of the technique, formal guidelines are necessary which will allow analyses to be performed with minimal requirements for regulator liaison meetings, external audits and extensive reporting. Structured and comprehensive guidelines, which have recently been constructed based on extensive analytical consideration of the underlying issues, are presented in this paper. The guidelines enable a ...

2000-07-01

409

Gas Storage Technology Consortium  

Energy Technology Data Exchange (ETDEWEB)

Gas storage is a critical element in the natural gas industry. Producers, transmission and distribution companies, marketers, and end users all benefit directly from the load balancing function of storage. The unbundling process has fundamentally changed the way storage is used and valued. As an unbundled service, the value of storage is being recovered at rates that reflect its value. Moreover, the marketplace has differentiated between various types of storage services and has increasingly rewarded flexibility, safety, and reliability. The size of the natural gas market has increased and is projected to continue to increase towards 30 trillion cubic feet over the next 10 to 15 years. Much of this increase is projected to come from electric generation, particularly peaking units. Gas storage, particularly the flexible services that are most suited to electric loads, is crucial in meeting the needs of these new markets. To address the gas storage needs of the ...

2007-06-30

410

Fundamentals of focused ion beam nanostructural processing: below,at and above the surface  

Energy Technology Data Exchange (ETDEWEB)

This article considers the fundamentals of what happens in asolid when it is impacted with a medium energy gallium ion. The study ofthe ion/sample interaction at the nanometer scale is applicable to mostfocused ion beam (FIB) based work even if the FIB/sample interaction isonly a step in the process, e.g., micromachining or microelectronicdevice processing. Whereas the objective in other articles in this issueis to use the FIB tool to characterize a material or to machine a deviceor transmission electron microscopy (TEM) sample, the goal of the FIB inthis article is to have the FIB/sample interaction itself become theproduct. To that end, the FIB/sample interaction is considered in threecategories according to geometry: below, at, and above the surface.First, the FIB ions can penetrate the top atom layer(s) and interactbelow the surface. Ion implantation and ion damage on flat surfaces havebeen comprehensively examined; however, FIB applications require thefurther ...

2007-03-30

411

Evaluation of technologies to improve truck efficiency  

Energy Technology Data Exchange (ETDEWEB)

The fuel economy of different types of trucks was simulated. Preliminary vehicle simulation activity took place in order to determine a feasible range of vehicle fuel efficiency improvements that could be obtained. Another objective was to provide a start to the Systems Analysis road mapping process in order to identify significant improvements for future studies at minimal costs. Technology improvements to all types of trucks were categorized in relation to engine improvements, the incorporation of continuously variable transmissions, hybrid drivetrain technology and improvements in aerodynamic drag, rolling resistance and weight reduction. The trucks which had the largest national impact were identified from data on vehicles, miles driven, fuel consumption and exhaust gases. The study involved Class 2B utility trucks, Class 6 enclosed delivery trucks, Class 8 transit buses and Class 8 tractor trailer trucks because they best represented the ...

2000-07-01

412

Energy Conversion and Storage Program: 1992 Annual report  

Energy Technology Data Exchange (ETDEWEB)

This report is the 1992 annual progress report for the Energy Conversion and Storage Program, a part of the Energy and Environment Division of the Lawrence Berkeley Laboratory. Work described falls into three broad areas: electrochemistry; chemical applications; and materials applications. The Energy Conversion and Storage Program applies principles of chemistry and materials science to solve problems in several areas: (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes and chemical species, and (5) study and application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry ...

1993-06-01

413

Economic-efficiency considerations in restructuring electric markets  

Energy Technology Data Exchange (ETDEWEB)

In response to the Energy Policy Act of 1992 and the Federal Energy Regulatory Commission`s subsequent rulemaking on transmission access, many states are exploring options to restructure their electric industries. In their deliberations on restructuring, policymakers should consider (1) the reliability of the electric system; (2) income-distribution effects on ratepayers and utilities; (3) social consequences such as effects on energy conservation, renewable energy, and the environment; and (4) economic efficiency. We address economic-efficiency considerations in this study. Economic efficiency is important because it is one of the primary reasons that policymakers should consider restructuring in the first place: improving the electric-industry`s efficiency lowers costs and, hence, electric prices. In this study, we look at the sources of (in)efficiency in existing and proposed electric markets with the objective of guiding policymakers to ...

1996-12-01

414

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to thicknesses of only a ...

2002-09-23

415

An analysis of selected atmospheric icing events on test cables  

Energy Technology Data Exchange (ETDEWEB)

In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud icing, glaze caused by freezing rain, wet ...

1996-12-01

416

Allocation of risks in a competitive electric market  

Energy Technology Data Exchange (ETDEWEB)

To many, recent developments in electric markets are perplexing. Competition has appeared, often in the form of new players who do not own and operate generation or transmission facilities. Yet, these players happily enter into contracts obliging them to make or take delivery of power at set prices for months or even years into the future. They seem unconcerned about predicted capacity shortages, fuel price uncertainty or unpredictable plant outages. For the most part, these new players understand these risks quite well. They simply believe in the efficacy of markets. Until recently, price ensured recovery of cost. They foresee a true market where price makes supply equal demand and cost is not a factor in the short term at least. The appearance of such players is an augury of the new industry structure, one in which specialists in taking and managing distinct business risks evolve from within or enter from outside. They take and manage price risk in much the same ...

1996-03-01

417

A wavelet-fuzzy combined approach for classification and location of transmission line faults  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a real-time wavelet-Fuzzy combined approach for digital relaying. The algorithm for fault classification employs wavelet multi resolution analysis (MRA) to overcome the difficulties associated with conventional voltage and current based measurements due to effect of factors such as fault inception angle, fault impedance and fault distance. The proposed algorithm for fault location, different from conventional algorithms that are based on deterministic computations on a well-defined model to be protected, employs wavelet transform together with fuzzy logic. The wavelet transform captures the dynamic characteristics of the non-stationary transient fault signals using wavelet MRA coefficients. The fuzzy logic is employed to incorporate expert evaluation through fuzzy inference system (FIS) so as to extract important features from wavelet MRA coefficients for obtaining coherent conclusions regarding fault location. Computer simulations using MATLAB ...

2007-11-15

418

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own ...

2006-03-01

419

Transmission nuclear resonance fluorescence measurements of "2"3"8U in thick targets  

International Nuclear Information System (INIS)

Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.

2011-05-15

420

Performance of the exploding bridgewire detonator with PETN  

Energy Technology Data Exchange (ETDEWEB)

Exploding bridgewire detonators with fine PETN powder were fabricated by the almost same method as the assembling process of ordinary electric detonators and the relationship between the detonating condition (bridge current waveform) in the single detonator initiation and the transmission time was studied. In addition, its jitter was also examined by simultaneous initiation of the detonators connected in series. It was revealed that the transmission time varied almost linearly against the inverse number of the rate of current rise and this variation was mainly due to the time needed for the bridgewire explosion. The jitter of the transmission time was within 0.1 microsecond. Although the cause of the jitter could not be determined, it was considered feasible to reduce the time jitter further by minimizing dimentional tolerances of fixing plugs and improving the loading process of PETN powder. 11 refs., 6 figs.

1989-02-25

421

In situ ultrahigh vacuum transmission electron microscopy studies of palladium silicide island formation on silicon (111) 7x7 surface  

International Nuclear Information System (INIS)

Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.

2003-01-22

422

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...

1986-04-01

423

Evaluation of Reports on Environmental Measurements of Electromagnetic Fields Generated by High Voltage Transmission Lines and Substations  

International Nuclear Information System (INIS)

This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the report should include measurements of electromagnetic fields of 50 ...

2007-01-01

424

Environmental and health effects of electric and magnetic fields from transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Concerns are sometimes expressed about an alleged link between exposure to the extremely low frequency electromagnetic fields occurring in proximity to electricity networks or equipment. Transmission lines are specifically mentioned. The underlying physical mechanisms are described by which electric and magnetic fields exist, with particular reference to high voltage transmission lines. Epidemiological and laboratory studies are the two approaches used in research into the subject and the shortcomings inherent in many such studies and the inconsistencies in the results are mentioned. Some of the more recent epidemiological studies are referred to, also the possible interaction mechanisms between fields and the human body. The work of certain international and national bodies which were established to review the results of research into the alleged association between electromagnetic fields and ill-health are reported. (R.P.)

1996-12-31

425

An assessment of health impacts of electrical power transmission lines  

International Nuclear Information System (INIS)

The types of investigations undertaken to test for possible biological effects of extremely low frequency electric fields have been numerous. However, neither animal and plant experimentation nor clinical studies nor experience with operating extremely high voltage transmission lines have to date provided convincing evidence of a harmful effect from exposure to electric fields associated with transmission lines in spite of numerous attempts to find such effects. Analysis of internal fields and currents supports these observations as the levels appear to be too low to affect mammalian cells. Thus, while one can never prove the negative (i.e. that there is no effect), the overwhelming body of evidence indicates that the electric fields associated with high-voltage lines have no deleterious biological effects. (author).

1981-06-26

426

Investigations on the braking safety of utility vehicles with retarders; Untersuchungen zur Bremssicherheit von Nutzfahrzeugen mit Retardern  

Energy Technology Data Exchange (ETDEWEB)

When the use of retarders in utility vehicles increased in the middle of the 80s, the Forschungsvereinigung Automobiltechnik (FAT) commissioned a study on the safety aspect of this braking technology in trucks. Retarders are wear-free permanent brakes that are fitted in the drive transmission system of utility vehicles, thereby generating braking forces only at the wheels of the live shaft. The question of the possible overbraking of the live shafts was just as well investigated as the interaction between the retarder and service brake in so-called integrated braking systems, and both under conditions of low adhesion as well as in the border area of the dynamics of vehicle movement. This subject met with considerable joint interest on the part of the motor vehicle industry as well as of manufacturers of towed vehicles and unit sets. FAT, therefore, commissioned the Institut fuer Kraftfahrwesen of the University of Hannover ...

1996-12-31

427

Commission for Energy regulation (CRE) - Activity report june 2008; Commission de regulation de l'energie (CRE) - Rapport d'activite juin 2008  

Energy Technology Data Exchange (ETDEWEB)

CRE is the French commission for energy regulation. CRE's remit is to assist in ensuring the proper operation of the electricity and natural gas markets for the benefit of the end-user. In particular, CRE ensures that the conditions of access to electricity and natural gas transmission and distribution systems do not hinder the development of competition. It monitors, for the electricity and natural gas sectors, all transactions made between suppliers, traders and producers, all transactions made on the organised markets and cross-border trading. It ensures that suppliers, traders and producers propose offers that are consistent with their financial and technical constraints. It monitors the implementation of and compliance with regulations giving consumers the right to choose their supplier in a competitive market, and allowing new suppliers to enter the market. This document is the 2008 activity report of CRE. Content: A - How CRE ...

2008-07-01

428

Zoonoses-With Friends Like This, Who Needs Enemies?  

UK PubMed Central (United Kingdom)

Zoonoses are infections that are spread from animals to humans. Most often, humans are “dead-end” hosts, meaning that there is no subsequent human-to-human transmission. If one considers...Full Text Available

2008-01-01

429

Transmission of Salmonella mbandaka to cattle from contaminated feed.  

UK PubMed Central (United Kingdom)

Salmonella mbandaka was isolated from cattle on three dairy farms. The duration of infection was less than four weeks and none of the animals became clinically ill. The animals had all consumed a diet...Full Text Available

1982-04-01

430

Transmission cycles of Borrelia burgdorferi and B. bissettii in relation to habitat type in northwestern California  

UK PubMed Central (United Kingdom)

This study was undertaken to determine which rodent species serve as primary reservoirs for the Lyme disease spirochete Borrelia burgdorferi in commonly occurring woodland types...Full Text Available

2009-06-01

431

The influence of electromagnetic field irradiated by high-voltage transmission lines on properties of cells.  

Science.gov (United States)

The influence of low-frequency electromagnetic field irradiating by high-voltage transmission lines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmission lines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this electromagnetic field. The spectra of ...

2005-01-01

432

The Dynamics of Naturally Acquired Immune Responses to Plasmodium falciparum Sexual Stage Antigens Pfs230 & Pfs48/45 in a Low Endemic Area in Tanzania  

UK PubMed Central (United Kingdom)

BackgroundNaturally acquired immune responses against sexual stages of P. falciparum can reduce the transmission of malaria from humans to mosquitoes. These antigens...Full Text Available

433

Syndecan-Fc Hybrid Molecule as a Potent In Vitro Microbicidal Anti-HIV-1 Agent?  

UK PubMed Central (United Kingdom)

In the absence of a vaccine, there is an urgent need for the development of safe and effective topical microbicides to prevent the sexual transmission of human immunodeficiency virus type 1 (HIV-1)....Full Text Available

2010-07-01

434

Sex and Death: The Effects of Innate Immune Factors on the Sexual Reproduction of Malaria Parasites  

UK PubMed Central (United Kingdom)

Malaria parasites must undergo a round of sexual reproduction in the blood meal of a mosquito vector to be transmitted between hosts. Developing a transmission-blocking intervention to prevent parasites...Full Text Available

2011-03-01

435

Seasonal and Regional Dynamics of M. ulcerans Transmission in Environmental Context: Deciphering the Role of Water Bugs as Hosts and Vectors  

UK PubMed Central (United Kingdom)

BackgroundBuruli ulcer, the third mycobacterial disease after tuberculosis and leprosy, is caused by the environmental mycobacterium M. ulcerans. Various modes of...Full Text Available

436

Ross River Virus Transmission, Infection, and Disease: a Cross-Disciplinary Review  

UK PubMed Central (United Kingdom)

Ross River virus (RRV) is a fascinating, important arbovirus that is endemic and enzootic in Australia and Papua New Guinea and was epidemic in the South Pacific in 1979 and 1980. Infection with RRV...Full Text Available

2001-10-01

437

Reproductive Success of Cavity-nesting Birds Breeding under High-voltage Powerlines  

Science.gov (United States)

... biological effects of electromagnetic fields (EMFs) produced by high-voltage transmission lines have come under intense scrutiny, mostly with respect ... biological effects of electromagnetic fields (EMFs...

438

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

439

Question box: a tool for gathering information about HIV and AIDS  

UK PubMed Central (United Kingdom)

Previous studies on knowledge of HIV transmission and prevention have used surveys. This study used the question box method to create a safe environment for collecting information on knowledge...Full Text Available

2010-10-01

440

Pulmonary endothelial and bronchiolar epithelial lesions induced by 4-ipomeanol in mice.  

UK PubMed Central (United Kingdom)

The morphogenesis of pulmonary edema and bronchiolar injury induced by the toxic furan, 4-ipomeanol, was studied by combined light and transmission electron microscopy. Weanling male CD-1 mice received...Full Text Available

1985-01-01

441

Project resumes: biological effects from electric fields associated with high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

1980-01-01

442

Prevalence of sexually transmissible pathogens in semen from asymptomatic male infertility patients with and without leukocytospermia  

UK PubMed Central (United Kingdom)

ObjectiveTo determine the prevalence of pathogens that cause sexually transmitted infections (STIs) in semen from asymptomatic male infertility patients with and...Full Text Available

2007-05-01

443

Persistence in herpes simplex virus infections.  

UK PubMed Central (United Kingdom)

Diseases of man caused by the virus of herpes simplex fall into two broad categories. The primary disease occurs only once in any individual's life and is caused by transmission of virus from an already...Full Text Available

1978-09-01

444

Options available and perceived constraints to implementation  

Energy Technology Data Exchange (ETDEWEB)

The economics of renewable energy technologies when deployed in a decentralised manner are more favourable than the simple cost of the fossil fuel generated electricity displaced. They have capital and maintenance cost savings associated with the electrical transmission in infrastructures which are avoided. Worked examples are presented. (UK)

1995-12-31

445

OLFACTORY CUES ARE SUFFICIENT TO ELICIT SOCIAL APPROACH BEHAVIORS BUT NOT SOCIAL TRANSMISSION OF FOOD PREFERENCE IN C57BL/6J MICE  

UK PubMed Central (United Kingdom)

Mouse models for the study of autistic-like behaviors are increasingly needed to test hypotheses about the causes of autism, and to evaluate potential treatments. Both the automated 3-chambered...Full Text Available

2008-11-21

446

Multiplicity of Plasmodium falciparum infection in asymptomatic children in Senegal: relation to transmission, age and erythrocyte variants  

UK PubMed Central (United Kingdom)

BackgroundIndividuals living in malaria endemic areas generally harbour multiple parasite strains. Multiplicity of infection (MOI) can be an indicator of immune status. However,...Full Text Available

447

Mortality of persons resident in the vicinity of electricity transmission facilities.  

UK PubMed Central (United Kingdom)

Several studies have raised the possibility that exposure to electrical and/or magnetic fields may be injurious to health in particular by the promotion or initiation of cancer. To investigate whether...Full Text Available

1986-02-01

448

Morphology and Ultrastructure of Maternal Seed Tissues of Soybean in Relation to the Import of Photosynthate  

UK PubMed Central (United Kingdom)

Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available

1981-05-01

449

Malaria vectors and transmission dynamics in coastal south-western Cameroon  

UK PubMed Central (United Kingdom)

BackgroundMalaria is a major public health problem in Cameroon. Unlike in the southern forested areas where the epidemiology of malaria has been better studied prior to the implementation...Full Text Available

450

Low-frequency sound transmission through a g... [J Acoust Soc...  

Science.gov (United States)

and antibody responses of rhesus macaques exposed to the human gammaretrovirus XMRV. J Virol. 2011 May ;85(9):4547-57. Epub 2011 Feb 16 . PubMed Surgical staging of early...

2011-10-15

451

Living and Working Around High-Voltage Power Lines.  

Energy Technology Data Exchange (ETDEWEB)

This booklet presents safe practices that you should follow if your activities take you near high-voltage transmission lines. It documents information that has generally been available to the public.

1981-08-01

452

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. ...

1986-01-01

453

Intrinsic plasticity complements LTP in parallel fiber input gain control in cerebellar Purkinje cells  

UK PubMed Central (United Kingdom)

Synaptic gain control and information storage in neural networks are mediated by alterations in synaptic transmission, such as in long-term potentiation (LTP). Here, we show using both in...Full Text Available

2010-10-13

454

Infection dynamics and clinical manifestations following experimental inoculation of gilts at 90 days of gestation with a low dose of porcine reproductive and respiratory syndrome virus  

UK PubMed Central (United Kingdom)

Understanding the dynamics of porcine reproductive and respiratory syndrome virus (PRRSV) vertical transmission is important to enhance the accuracy of monitoring protocols for endemically infected...Full Text Available

2009-10-01

455

Infected foot ulcers in male and female diabetic patients: a clinico-bioinformative study  

UK PubMed Central (United Kingdom)

BackgroundThe study aimed at (i) characterizing the mode of transmission of blaCTX-M and blaTEM-1 among extended-spectrum-β-lactamase...Full Text Available

456

Induction and transmission of Bacillus thuringiensis tolerance in the flour moth Ephestia kuehniella  

UK PubMed Central (United Kingdom)

The use of Bacillus thuringiensis (Bt) endotoxins to control insect vectors of human diseases and agricultural pests is threatened by the possible evolution of resistance in major pest...Full Text Available

2004-03-02

457

Induced voltage in a shared corridor  

Energy Technology Data Exchange (ETDEWEB)

The induction of voltages on pipelines and railroad signal wires can be a problem when high-voltage transmission lines share the right of way. A handbook and two computer programs provide the analytic tools for utilities to avoid the problem.

1983-10-01

458

Inactivation of Ascaris Eggs in Source-Separated Urine and Feces by Ammonia at Ambient Temperatures?  

UK PubMed Central (United Kingdom)

Sustainable management of toilet waste must prevent disease transmission but allow reuse of plant nutrients. Inactivation of uterus-derived Ascaris suum eggs was studied in relation...Full Text Available

2009-02-01

459

In-Space Propulsion Program Advanced Sensor Project - NASA  

Science.gov (United States)

Aug 25, 2004 ... Current Developments in Future Planetary Probe Sensors: .... Data: Outgoing and incoming EIA RS-422 interface for serial data transmission (for electrical purposes only, .... Milos, et. al, Journal of Spacecraft & Rockets 1999 ...

460

Hypoglycaemia and severe plasmodium falciparum malaria among pregnant sudanese women in an area characterized by unstable malaria transmission  

UK PubMed Central (United Kingdom)

BackgroundPregnant women are more susceptible to severe Plasmodium falciparum malaria, which can lead to poor maternal and fetal outcomes. Few data exist on the...Full Text Available

461

Horizontal Transmissible Protection against Myxomatosis and Rabbit Hemorrhagic Disease by Using a Recombinant Myxoma Virus  

UK PubMed Central (United Kingdom)

We have developed a new strategy for immunization of wild rabbit populations against myxomatosis and rabbit hemorrhagic disease (RHD) that uses recombinant viruses based on a naturally attenuated field...Full Text Available

2000-02-01

462

Helical piles for power transmission lines : case study in northern Manitoba  

Energy Technology Data Exchange (ETDEWEB)

This document presented the results of a full-scale pile load tests conducted on helix pile foundations supporting power transmission towers in northern Manitoba. The site conditions were described along with pile installation and the performance of the foundations. The pile load tests were carried out in 2 different soil conditions, notably soft to firm clays and stiff high plastic clays with silt varves. The performance of the helix pile foundations were examined under axial compressive and axial tension (uplift) loading conditions. The results of the compressive load tests were presented in the form of load settlement curves while the results of the uplift load tests were presented in the form of load displacement curves. Both types of load tests in soft or stiff clays showed the suitability of helical pile foundations for power transmission lines in northern Manitoba. The cylindrical shear failure mechanism controlled the behaviour of ...

2008-07-15

463

Genetic Modulation of GABA Levels in the Anterior Cingulate Cortex by GAD1 and COMT  

UK PubMed Central (United Kingdom)

γ-Aminobutyric acid (GABA)-ergic transmission is critical for normal cortical function and is likely abnormal in a variety of neuropsychiatric disorders. We tested the in...Full Text Available

2010-07-01

464

From Leningrad to the day-care center. The ubiquitous Giardia lamblia.  

UK PubMed Central (United Kingdom)

Giardiasis is recognized as a worldwide public health problem. Seroprevalence data from both the developing and developed world show high rates of carriage in populations at risk for fecal-oral transmission,...Full Text Available

1990-08-01

465

Factors underlying diagnostic delay in tuberculosis patients in a rural area in Tanzania: a qualitative approach  

UK PubMed Central (United Kingdom)

BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available

2010-12-01

466

Electric and magnetic field exposures for people living near a 735-kilovolt power line.  

UK PubMed Central (United Kingdom)

The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available

1995-09-01

467

Development of Two PCR-Based Techniques for Detecting Helical and Coccoid Forms of Helicobacter pylori  

UK PubMed Central (United Kingdom)

The primary mode of transmission of Helicobacter pylori, a human pathogen carried by more than half the population worldwide, is still unresolved. Some epidemiological data suggest...Full Text Available

2004-08-01

468

Detection of Sub-Clinical CWD Infection in Conventional Test-Negative Deer Long after Oral Exposure to Urine and Feces from CWD+ Deer  

UK PubMed Central (United Kingdom)

BackgroundChronic wasting disease (CWD) of cervids is a prion disease distinguished by high levels of transmissibility, wherein bodily fluids and excretions are thought to play an...Full Text Available

469

Dengue Fever in Humanized NOD/SCID Mice  

UK PubMed Central (United Kingdom)

The increased transmission and geographic spread of dengue fever (DF) and its more severe presentation, dengue hemorrhagic fever (DHF), make it the most important mosquito-borne viral disease of humans...Full Text Available

2005-11-01

470

Coping with crowds: Density-dependent disease resistance in desert locusts  

UK PubMed Central (United Kingdom)

Parasite transmission generally exhibits some form of positive density dependence. Thus, as population density increases, so too does the per capita risk of becoming infected. Under...Full Text Available

2002-04-16

471

Control of intestinal parasitic infections in Seychelles: a comprehensive and sustainable approach.  

UK PubMed Central (United Kingdom)

Intestinal parasitic infections have been perceived as a public health problem in Seychelles for decades. A comprehensive strategy to reduce morbidity and, in the long term, transmission of intestinal...Full Text Available

1996-01-01

472

Cholinergic Interneurons Mediate Fast VGluT3-Dependent Glutamatergic Transmission in the Striatum  

UK PubMed Central (United Kingdom)

The neurotransmitter glutamate is released by excitatory projection neurons throughout the brain. However, non-glutamatergic cells, including cholinergic and monoaminergic neurons, express markers that...Full Text Available

473

Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators  

Energy Technology Data Exchange (ETDEWEB)

Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. Several ...

1992-03-01

474

Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators  

International Nuclear Information System (INIS)

Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. Several hundred men ...

1992-01-01

475

Biopersistence of nonfibrous mineral particles in the respiratory tracts of subjects following occupational exposure.  

UK PubMed Central (United Kingdom)

Transmission electron microscopy analysis (TEMA) was used to analyze the bronchoalveolar lavage fluid (BALF) of 262 subjects occupationally exposed (OE) to nonfibrous mineral particles (NFMP) and 42...Full Text Available

1994-10-01

476

A morphological and morphometric study of the prosimian lung: the lesser bushbaby Galago senegalensis.  

UK PubMed Central (United Kingdom)

The lung of the lesser bushbaby (Galago senegalensis) has been investigated morphologically and morphometrically using the transmission and scanning electron microscopes. Grossly and microscopically,...Full Text Available

1990-10-01

477

A high-speed network for cardiac image review.  

UK PubMed Central (United Kingdom)

A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available

1994-01-01

478

A Simple Colorimetric Assay for Specific Detection of Glutathione-S Transferase Activity Associated with DDT Resistance in Mosquitoes  

UK PubMed Central (United Kingdom)

BackgroundInsecticide-based methods represent the most effective means of blocking the transmission of vector borne diseases. However, insecticide resistance poses a serious threat...Full Text Available

479

A Research Agenda for Malaria Eradication: Drugs  

UK PubMed Central (United Kingdom)

Antimalarial drugs will be essential tools at all stages of malaria elimination along the path towards eradication, including the early control or “attack” phase to drive down transmission...Full Text Available

2011-01-01

480

A Rare Null Allele Potentially Encoding a Dominant-Negative TRIM5? Protein in Baka Pygmies  

UK PubMed Central (United Kingdom)

The global acquired immunodeficiency syndrome (AIDS) pandemic is thought to have arisen by the transmission of human immunodeficiency virus (HIV-1)-like viruses from chimpanzees in southeastern...Full Text Available

2009-08-15

481

A Habitat-Based Model for the Spread of Hantavirus Between Reservoir and Spillover Species  

UK PubMed Central (United Kingdom)

New habitat-based models for spread of hantavirus are developed which account for interspecies interaction. Existing habitat-based models do not consider interspecies pathogen transmission,...Full Text Available

2009-10-21

482

500 kV oil-filled cable installed on bridges  

Energy Technology Data Exchange (ETDEWEB)

The 220 kV Ch{bar u}si Trunk Line, now transmitting a maximum of 300 MW of electricity between the Ch{bar u}goku area of Honsh{bar u} and Shikoku island, is expected to be inadequate in the 1990's due to the rise in electrical demand. Therefore, to strengthen this interconnection, a new 500 kV transmission line was proposed. The most significant feature of this transmission line is the installation of 500 kV cables along the bridges (the Seto Ohashi Bridge) which span the Inland Sea (Seto). This is the first 500 kV long-distance transmission cable line. It is also the first large-scale cable line in the world installed along various types of bridges (ten bridges; route length of the bridge portion approximately 8 km). This paper gives an outline of the Honsh{bar u}---Shikoku interconnecting transmission line and also presents some technical features concerning 500 kV cables.

1990-04-01

484

Transmission electron microscopy of simulated DWPF high level nuclear waste glasses following gamma irradiation  

International Nuclear Information System (INIS)

Thermal analysis testing revealed slight weight changes, which were a function of gamma irradiation, in a highly reduced Defense Waste Processing Facility (DWPF) simulated waste glass. Transmission electron microscopy (TEM) was performed on this glass to determine if the weight change corresponded to microstructural variations. TEM analyses showed that no microstructural changes were attributable to gamma irradiation. Exposure of the samples to the electron beam in the TEM did cause changes in the glass microstructures in some cases. These changes were likely due to localized heating of the glass due to interactions with the transmitted electrons.

1994-04-25

485

Secondary stresses on transmission tower structures  

Energy Technology Data Exchange (ETDEWEB)

The power industry is moving toward the use of high-voltage transmission lines on tall, flexible towers. These towers are designed for heavier loadings than were previous towers, but the secondary effects of tower displacement tend to be ignored in the present day tower analysis. This paper examines the secondary effects from the large displacement of flexible towers, reviews the secondary stresses arising from joint rigidity and member continuity, and examines the reliability of tower strength predicted by the ASCE design guidelines. More realistic tower test acceptance criteria and a more reliable tower design methodology are suggested.

1984-06-01

486

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

Energy Technology Data Exchange (ETDEWEB)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.))

1994-06-01

487

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

International Nuclear Information System (INIS)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.)).

1994-01-01

488

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

489

MITL - A 2-D code to investigate electron flow through non-uniform field region of magnetically insulated transmission lines  

Science.gov (United States)

Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.

1979-01-01

490

MIMO APP Receiver Processing with Performance-Determined Complexity  

CERN Document Server

Typical receiver processing, targeting always the best achievable bit error rate performance, can result in a waste of resources, especially, when the transmission conditions are such that the best performance is orders of magnitude better than the required. In this work, a processing framework is proposed which allows adjusting the processing requirements to the transmission conditions and the required bit error rate. It applies a-posteriori probability receivers operating over multiple-input multiple-output channels. It is demonstrated that significant complexity savings can be achieved both at the soft, sphere-decoder based detector and the channel decoder with only minor modifications.

2010-01-01

491

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

492

Environmental and health effects of electric and magnetic fields from transmission lines  

International Nuclear Information System (INIS)

The paper outlines the underlying physical mechanisms by which electric and magnetic fields exist, with particular reference to high voltage transmission lines. Epidemiological and laboratory studies are the two approaches used in research into the subject and the shortcomings and inconstancies in the results are mentioned. Recent epidemiological results are presented together with possible mechanisms between fields and the human body. Attention is drawn to the work of certain international and national bodies concerning the alleged association between electromagnetic fields and ill-health, and their conclusions are reported. Finally, the policy of the Electricity Supply Board in Ireland is outlined. 2 figs.

1995-05-01

493

Electric induction on a trolley bus contact line, running parallel to a 138 KV overhead transmission line; Inducao em linha de contato de trolebus paralela a uma linha de transmissao de 138 kV  

Energy Technology Data Exchange (ETDEWEB)

Results obtained on induced current and voltage caused by a high voltage transmission lines running parallel at a trolley bus contact lines, are presented. A computer program in Basic language, was developed to calculate the electric induction, problems of safety, a theoretical development and mathematical model of the electric factors between two lines (inductor and induced) are also discussed. 11 figs., 1 tab., 8 refs.

1991-12-31

494

Manitoba Hydro long-term high-voltage transmission line magnetic field monitoring project  

International Nuclear Information System (INIS)

As part of the licensing process to construct a new 230 kV transmission line on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmission lines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission line was energized by Manitoba Hydro. This paper described the ...

2008-10-19

495

Interrelation between grain boundary characteristics and intergranular stress corrosion cracking of thermally treated alloy 690 and shot peened alloy 800 in high temperature acidic and alkaline solution  

International Nuclear Information System (INIS)

To clarify the acidic and alkaline Intergranular Stress Corrosion Cracking (IGSCC) mechanism of thermally treated alloy 690 (alloy 690 TT) and shot peened alloy 800 (alloy 800 SP), C-ring tests were conducted in deaerated HCl solutions and in deaerated NaOH solutions at 350degC, compared with the acidic and the alkaline IGSCC susceptibilities of mill-annealed alloy 600 (alloy 600 MA), full-sensitized one (alloy 600 FS) and thermally treated one (alloy 600 TT). Grain boundary characteristics, such as chromium depleted zone and chromium carbide precipitation, were examined using modified Huey test and Transmission Electron Microscopy. Potential-pH diagram for Ni, Cr, Fe-H_2O system at 350degC was constructed and the solubilities of NiO, Cr_2O_3 and Fe_3O_4 were also calculated to evaluate the stability of oxide films which were formed on the surfaces of alloy 690, 800 and 600. Under the acidic condition, the IGSCC susceptibility of alloy 800 SP ...

2001-05-01

496

Correlation between tensile property and micro-hardness in reduced activation ferritic/martensitic steel irradiated at 573 K  

International Nuclear Information System (INIS)

Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials used in this study were F82H IEA heat and F82H heat treatment variants. Neutron irradiation was ...

2007-12-10