WorldWideScience
 
 
2

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

3

Course and Curriculum Development Program, Evaluation Report  

Science.gov (United States)

... grants to adopt or adapt courses and materials developed by CCD projects at other institutions, and ... to adopt or adapt CCD-developed courses and materials. -iv- Accomplishments The CCD program has ...

4

Effect of triple ion beams in ferritic/martensitic steel on swelling behavior  

Energy Technology Data Exchange (ETDEWEB)

The synergistic effects of displacement damage and atomic hydrogen and helium on swelling of the ferritic/martensitic steel, F82H, has been investigated. The irradiation was performed at temperatures between 470 and 600 deg. C to 50 dpa (displacement per atoms) under conditions of simultaneous ion beams consisting of Fe{sup 3+}, He{sup +} and H{sup +} ions or Fe{sup 3+} and He{sup +} ions. The swelling of F82H steel under triple beams with 18 appm He/dpa and 70 appm H/dpa was larger than that under dual beams with 18 appm He/dpa. The swelling in F82H under triple beams increased with decreasing irradiation temperature from 0.1% to 3.2%, while swelling under dual beams was between 0.04% and 0.08%. On the other hand, in the case of triple beam irradiation with a high ratio of gas/dpa, the swelling tended to increase with irradiation temperature. The swelling in ...

2002-12-01

5

Effect of triple ion beams in ferritic/martensitic steel on swelling behavior  

International Nuclear Information System (INIS)

The synergistic effects of displacement damage and atomic hydrogen and helium on swelling of the ferritic/martensitic steel, F82H, has been investigated. The irradiation was performed at temperatures between 470 and 600 deg. C to 50 dpa (displacement per atoms) under conditions of simultaneous ion beams consisting of Fe"3"+, He"+ and H"+ ions or Fe"3"+ and He"+ ions. The swelling of F82H steel under triple beams with 18 appm He/dpa and 70 appm H/dpa was larger than that under dual beams with 18 appm He/dpa. The swelling in F82H under triple beams increased with decreasing irradiation temperature from 0.1% to 3.2%, while swelling under dual beams was between 0.04% and 0.08%. On the other hand, in the case of triple beam irradiation with a high ratio of gas/dpa, the swelling tended to increase with irradiation temperature. The swelling in ferritic/martensitic ...

2002-12-01

6

Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems  

Energy Technology Data Exchange (ETDEWEB)

We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.

2006-03-06

8

Swelling behavior of a simple ferritic alloy  

International Nuclear Information System (INIS)

The swelling behavior which results from simulated fusion environment irradiation of Fe-10% Cr has been characterized with transmission electron microscopy. Specimens were bombarded at 850 K with: a ''triple-beam'' of He"+, D_2"+, and 4 MeV Fe"+"+ ions to 0.3, 1, 3, 10, 30, and 100 dpa (displacement per atom); a ''dual-beam'' of He"+ and 4 MeV Fe"+"+ ions to 30 and 100 dpa; and a ''single-beam'' of 4 MeV Fe"+"+ ions to 30 dpa. The helium and hydrogen injection rates were approx. =10 appm He/dpa and approx. =40 appm D/dpa. Cavities were observed for damage levels of 3 dpa and greater. The swelling was <0.1% for damage levels <30 dpa, but at 100 dpa, there was an increase in the swelling to 2.5% for the ''triple-beam'' irradiation and 1.2% for the ''dual-beam'' irradiation. The swelling rates between 30 and 100 dpa correlate well with calculated values assuming a steady-state swelling-rate regime has been reached. Calculations show the ...

9

Effect of helium and hydrogen production on hardness of F82H steel irradiated by dual/triple ion beams  

International Nuclear Information System (INIS)

Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation was harder than that ...

2003-03-01

10

Iao: The New Adaptive Optics Visible Imaging and ...  

Science.gov (United States)

... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...

2008-09-01

11

Triple ion-beam studies of radiation damage in 9Cr2WVTa ferritic/martensitic steel  

Energy Technology Data Exchange (ETDEWEB)

To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa ...

1997-11-01

12

Effect of helium and hydrogen production on irradiation hardening of F82H steel irradiated by ion beams  

International Nuclear Information System (INIS)

Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, respectively, by dual ion beams. The hardness of the specimens ...

2007-06-01

13

Ultra-fast charge transfer in organic electronic materials and at hybrid interfaces studied using the core-hole clock technique  

Energy Technology Data Exchange (ETDEWEB)

Research highlights: {yields} The use of resonant photoemission in its 'core-hole clock' expression for the study of the dynamical charge transfer across hybrid organic-inorganic interfaces and for the intermolecular charge transfer in the bulk of organic thin films is reviewed. {yields} The electronic coupling to the substrate and the efficiency of charge transport across hybrid interfaces is different for individual electronic subsystems of the molecular adsorbate. {yields} The intermolecular charge transfer in the bulk of discotic liquid crystals occurs on the order of a few femtoseconds and is faster than expected from the macroscopic charge transport characteristics of the material. -- Abstract: The focus of this brief review is the use of resonant photoemission in its 'core-hole clock' expression for the study of two important problems relevant for the field of organic electronics: the dynamical charge transfer across hybrid organic-inorganic ...

2011-01-15

14

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

15

Improving T D reliability. How pumped storage can boost network security  

Energy Technology Data Exchange (ETDEWEB)

The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, provides 5000 acre-ft of active storage volume ...

1994-03-01

16

High-performance hybrid pervaporation membranes with superior hydrothermal and acid stability  

Energy Technology Data Exchange (ETDEWEB)

A new organic-inorganic hybrid membrane has been prepared with exceptional performance in dewatering applications. The only precursor used in the sol-gel synthesis of the selective layer was organically linked 1,2-bis(triethoxysilyl)ethane (BTESE). The microporous structure of this layer enables selective molecular sieving of small molecules from larger ones. In the dehydration of n-butanol with 5% of water, the membrane shows a high separation factor of over 4000 and ultra-fast water transport at a rate of more than 20 kg m{sup -2} h{sup -1} at 150C. This can be related to the high adsorption capacity of the material and the sub-micron thickness of the selective layer. The selectivity has now remained constant over almost one and a half years under continuous process testing conditions. Apart from the hydrothermal stability, the membrane exhibits a high tolerance for acid contamination. A slow performance decline in flux and separation factor is only observed at a ...

2009-05-15

17

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

18

Color recognition system for urine analyzer  

Science.gov (United States)

In order to increase the speed of photoelectric conversion, a linear CCD is applied as the photoelectric converter instead of the traditional photodiode. A white LED is used as the light source of the system. The color information of the urine test strip is transferred into the CCD through a reflecting optical system. It is then converted to digital signals by an A/D converter. The test results of urine analysis are obtained by a data processing system. An ARM microprocessor is selected as the CPU of the system and a CPLD is employed to provide a driving timing for the CCD drive and the A/D converter. Active HDL7.2 and Verilog HDL are used to simulate the driving timing of the CPLD. Experimental results show that the correctness rate of the test results is better than 90%. The system satisfies the requirements of the color information collection of urine analyzer.

2010-08-01

19

PKC expression is regulated by dietary K intake and mediates internalization of SK channels in the CCD  

UK PubMed Central (United Kingdom)

We have used Western blot analysis and immunocytochemistry to determine the effect of dietary K intake on the expression of protein kinase C (PKC) isoforms in the kidney. Western blot has demonstrated...Full Text Available

2004-06-01

20

Ionizing radiation hardening procedure of CCD's  

International Nuclear Information System (INIS)

The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.

 
 
 
 
21

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

22

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

23

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise ...

2004-12-07

24

The stellar content of central dominant galaxies. I. CCD surface photometry  

International Nuclear Information System (INIS)

UBVRI CCD surface photometry and color gradients are presented for 10 central dominant galaxies (CDGs), comprising gE, D, and cD morphological types and covering the range of Bautz-Morgan cluster types. The mean magnitude of the color gradients to a radius of 20 kpc is in agreement with those found in recent CCD studies of bright ellipticals in Virgo. The size of the gradients are consistent with N-body model predictions in which these galaxies are formed or enhanced by merger events. Parameters such as ellipticity, position angle of the major axis, and deviation from ellipticity for eight single-nucleus CDGs are also given. All galaxies show large changes in ellipticity and position angle with radius, and can be considered similar to Kormendy's T3 class of galaxies, in which tidal effects on isophotal structure are very probable. Three out of eight single-nucleus CDGs, NGC 1399, NGC 6876 and IC 1860, show evidence of isochromal flattening ...

25

The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)  

CERN Document Server

The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was released at the IAU General Assembly on 2009 August 10. It is the first all-sky release in this series and contains just over 100 million objects, about 95 million of them with proper motions, covering about R = 8 to 16 magnitudes. Current epoch positions are obtained from the observations with the 20 cm aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates from the SPM program (YSJ1) form the basis for proper motions. These data are supplemented by all-sky Schmidt plate survey astrometry and photometry obtained from the SuperCOSMOS project, as ...

2010-01-01

26

Surface modification with BSA blocking based on in situ synthesized gold nanoparticles in poly(dimethylsiloxane) microchip  

British Library Electronic Table of Contents (United Kingdom)

A stable BSA blocking poly(dimethylsiloxane) (PDMS) microchannel was prepared based on in situ synthesized PDMS-gold nanoparticles composite films. The modified microchip could successfully suppress protein adsorption. The assembly was followed by contact angle, charge-coupled device (CCD) imaging, electroosmotic flow (EOF) measurements and electrophoretic separation methods. Contact angle measurements revealed the coated surface was hydrophilic, water contact angle for coated chips was 45.2^o compared to a water contact angle for native PDMS chips of 88.5^o. The coated microchips exhibited reproducible and stable EOF behavior. With FITC-labeled myoglobin incubation in the coated channel, no fluorescence was observed with CCD image, and the protein exhibited good electrophoretic effect in ...

2010-01-01

27

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

28

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

29

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

30

Optimization of alkaline hydrolysis of paddy straw for ferulic acid extraction  

British Library Electronic Table of Contents (United Kingdom)

Response Surface Methodology (RSM) via Central Composite Design (CCD) was used to optimize the alkaline hydrolysis of paddy straw to improve ferulic acid extraction. The parameters involved, namely temperature (^oC), concentration of NaOH (M) and duration of extraction (h) are screened by Full Factorial Studies (FFD). The result obtained from FFD was 0.518% (5.18mg/g). The interactions between each parameters involved were studied using Central Composite Design (CCD). Upon optimization, the percentage of ferulic acid improved from 0.518% to 0.817% (8.17mg/g). The optimum conditions obtained from this study are 125^oC, 3.90M, 2.30h for temperature, concentration of NaOH and extraction time, respectively. This result shows a significant improvement than the previous published work. Details o...

2011-01-01

31

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

32

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

33

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-15

34

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-01

35

Characterization of Adaptive Optics at Keck Observatory  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.

2003-07-24

36

A Brief History of Astronomical Brightness Determination Methods at Optical Wavelengths  

CERN Document Server

In this brief article I review the history of astronomical photometry, touching on observations made by the ancient Chinese, Hipparchus and Ptolemy, the development of the concept (and definition) of magnitude, the endeavors of Argelander and Zoellner, work at Harvard at the end of the 19th century, and the development of photography, photomultipliers, and CCD's and their application to astronomy.

2001-01-01

37

Rayleigh Laser Guide Star Systems UnISIS Bow Tie Shutter and CCD39 Wavefront Camera  

CERN Document Server

Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie arrangement.

2002-01-01

38

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and ...

1997-12-31

39

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and ...

2008-04-01

40

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

 
 
 
 
41

Numerical simulation and experiment research of radiation performance in a dish solar collector system  

British Library Electronic Table of Contents (United Kingdom)

The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.

2010-01-01

42

Low cost, low power, high sensitivity, real time neutron detection microsystem  

International Nuclear Information System (INIS)

A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.

2002-10-10

43

Laser ray-tracing method for optical testing.  

Science.gov (United States)

We have developed a novel laser ray-tracing method to measure aberrations in optical systems. It consists of delivering narrow laser pencils (by a laser scanner), recording the spots that are formed on the image plane (with a CCD camera), and computing the position of each centroid. This approach could be considered an experimental (approximate) implementation of standard numerical ray tracing. Several tests and experiments, including a direct comparison with a Hartmann-Shack wave-front sensor, provided highly satisfactory results that confirmed the validity of the method and revealed potential advantages. PMID:18073906

1999-07-15

44

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

45

Cores of early-type galaxies - the nature of dwarf spheroidal galaxies  

International Nuclear Information System (INIS)

The characteristics and evolution of dwarf spheroidal galaxies (DSGs) are modeled on the basis of high-resolution CCD photometry obtained with the Canada-France-Hawaii telescope and reported by Kormendy (1986). The data and the results of core-parameter correlation studies are presented in extensive graphs and discussed. It is inferred that at least some DSGs are formed by the stripping of gas from dwarf spiral and irregular galaxies, although internal gas processes may also be important. The hypothesis that DSGs represent the faint end of the elliptical-galaxy sequence appears to be ruled out. 50 references.

46

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

47

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide ...

1993-12-01

48

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

49

Two-step biodiesel production from Calophyllum inophyllum oil: Optimization of modified b-zeolite catalyzed pre-treatment  

British Library Electronic Table of Contents (United Kingdom)

In this study, a two-step process was developed to produce biodiesel from Calophyllum inophyllum oil. Pre-treatment with phosphoric acid modified b-zeolite in acid catalyzed esterification process preceded by transesterification which was done using conventional alkali catalyst potassium hydroxide (KOH). The objective of this study is to investigate the relationship between the reaction temperatures, reaction time and methanol to oil molar ratio in the pre-treatment step. Central Composite Design (CCD) and Response Surface Methodology (RSM) were utilized to determine the best operating condition for the pre-treatment step. Biodiesel produced by this process was tested for its fuel properties.

2011-01-01

50

Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)

1996-12-31

51

Sejong Open Cluster Survey. I. NGC 2353  

CERN Document Server

UBVI CCD photometry of NGC 2353 is obtained as part of the "Sejong Open cluster Survey" (SOS). Using the photometric membership criteria we selelct probable members of the cluster. We derive the reddening and distance to the cluster, i.e. E(B-V) = 0.10 +/- 0.02 mag and 1.17 +/- 0.04 kpc, respectively. We find that the projected distribution of the probable members on the sky is elliptical in shape rather than circular. The age of the cluster is estimated to be log(age)=8.1 +/- 0.1, older than what was found in previous studies. The minimum value of binary fraction is estimated to be about 48 +/- 5 percent from a Gaussian function fit to the distribution of the distance moduli of the photometric members. Finally, we also obtain the luminosity function and the initial mass function (IMF). The slope of the IMF is Gamma = -1.3 +/- 0.2.

2011-01-01

52

Rapid optical variability of TeV blazars  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this first systematic attempt to characterize the intranight optical variability (INOV) of TeV-detected blazars, we have monitored a well-defined set of nine TeV blazars on total 26 nights during 2004-10. In this R- or V-band-monitoring programme only one blazar was monitored per night and the minimum duration was close to 4-h, the average being 5.3 h per night. Using the CCD for strictly simultaneous photometry of the blazar and nearby reference stars (N-star photometry), an INOV detection threshold of -1-2-per cent was achieved in the densely sampled differential light curves derived from our data. We have further expanded the sample by including another 13 TeV blazars, taking advantage of the availability in the literature of INOV data, including those published earlier in o...

2011-01-01

53

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

54

Ovis aries CR4 is involved in Mannheimia haemolytica leukotoxin-induced cytotoxicity  

British Library Electronic Table of Contents (United Kingdom)

Pneumonia caused by Mannheimia haemolytica is an important disease of domestic sheep (DS, Ovis aries) and cattle (BO). M. haemolytica is a normal commensal of the upper respiratory tract in ruminants, but during stress and viral infection it breaches the host innate mucosal defense and descents into lungs causing fibrinous pleuropneumonia. Leukotoxin (Lkt) produced by M. haemolytica is cytolytic to all subsets of ruminant leukocytes. Earlier, we and others have shown that DS and BO LFA-1 (CD11a/CD18) and Mac-1 (CD11b/CD18) can mediate Lkt-induced cytolysis. It is not clear whether CR4 (CD11c/CD18), which is involved in chemotaxis, phagocytosis and regulates host immune response can also mediate Lkt-induced cytolysis in ruminants. The host innate immune response to M. haemolytica is poorly ...

2010-01-01

55

Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam  

CERN Document Server

TRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION RADIATION) SCREEN AND A FAST CCD (CHARGED COUPLED DEVICE) CAMERA, THE PHASE SPACE MATCHING AT INJECTION IS MONITORED BY AN OTR BASED MISMATCH MONITOR IN THE SPS RING. ORTHOGONAL TUNING KNOBS WERE DEVELOPED TO TUNE INDEPENDENTLY TWISS PARAMETERS, DISPERSION AND DISPERSION DERIVATIVE. IN THIS PAPER WE DESCRIBE THE MISMATCH CORRECTION MECHANISM AS WELL AS THE TWO MONITORING SYSTEMS. WE REPORT ON FIRST MEASUREMENTS WHICH WERE CARRIED OUT DURING THE 1998 SPS RUN.

1999-01-01

56

Ionized gas and radio emission in the barred Seyfert galaxy NGC 5728  

International Nuclear Information System (INIS)

This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.

57

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

58

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

59

Evaluation of cortical current density imaging methods using intracranial electrocorticograms and functional MRI  

British Library Electronic Table of Contents (United Kingdom)

Objective:EEG source imaging provides important information regarding the underlying neural activity from noninvasive electrophysiological measurements. The aim of the present study was to evaluate source reconstruction techniques by means of the intracranial electrocorticograms (ECoGs) and functional MRI.Methods:Five source imaging algorithms, including the minimum norm least square (MNLS), LORETA with Lp-norm (p equal to 1, 1.5 and 2), sLORETA, the minimum Lp-norm (p equal to 1 and 1.5; when p=2, the MNLS method is mathematically equivalent to the minimum Lp-norm) and L1-norm (the linear programming) methods, were evaluated in a group of 10 human subjects, in a paradigm with somatosensory stimulation. Cortical current density (CCD) distributions were estimated from the scalp somatosensor...

2007-01-01

60

Enhancement of bioleaching of a spent Ni/Mo hydroprocessing catalyst by Penicillium simplicissimum  

British Library Electronic Table of Contents (United Kingdom)

Statistically based experimental designs were applied to screen and optimize the bioleaching of spent hydrocracking catalyst by Penicillium simplicissimum. Eleven factors were examined for their significance on bioleaching using a Plackett-Burman factorial design. Four significant variables (pulp density, sucrose, NaNO"3, and yeast extract concentrations) were selected for the optimization studies. The combined effect of these variables on metal bioleaching was studied using a central composite design (CCD). Second-order polynomials were established to identify the relationship between the recovery percent of the metals and the four significant variables. The optimal values of the variables for maximum metals bioleaching were as follows: pulp density (4.0%, w/v), sucrose (90g/L), NaNO"3 (2...

2011-01-01

 
 
 
 
61

Effects of cultivar and culture conditions on g-aminobutyric acid accumulation in germinated fava beans (Vicia faba L.)  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: High levels of g-aminobutyric acid (GABA) accumulate in plant tissues under various stresses. GABA accumulation is also influenced by cultivar. This aim of this study was to select the most promising cultivar of fava bean for GABA accumulation and to optimise the culture conditions for GABA production in germinated fava beans by response surface methodology based on central composite design (CCD). RESULTS: GABA content and glutamate decarboxylase activity in germinated seeds of cultivar S2 were significantly higher than those in other cultivars (P < 0.05). A significant negative correlation (r = -0.765, P < 0.05) between germination percentage and 1000-kernel weight was observed. There was a linear relationship between GABA content and sprout length (R2 = 0.816). The regression...

2010-01-01

62

A six-axes robot for deep water applications  

Energy Technology Data Exchange (ETDEWEB)

The six-axes industrial robot MANUTEC r15 UW was modified to work underwater and successfully tested down to the simulated water depth of 1100 m. Next step in the program was to use this robot as a handling tool for inspection tasks at the welding seam of an underwater structure conducted with CCD-cameras and distance sensors. This was also to demonstrate the possibility to assist and later on to replace divers from this work. Additional research was focussed on the stiffness and rigidity of the robot during the precise guiding of tools and workpieces under current water conditions up to a flow velocity of 1.1 m/s. Present work is concentrated on the application of this subsea robot on a maintenance task at the Brazilian underwater template OCTOS-1000. For this experiments the robot is integrated in a large mock-up which simulates a quarter section of this template. (orig.)

1994-01-01

63

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...

1990-12-20

64

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...

1990-12-01

65

[Improvement of the recognition probability about camouflage target based on BP neural network].  

Science.gov (United States)

Using static Michelson interferometer to get the spectrum information of measurement targets for spectrum identification, under the condition that the interference length is constant, the system can be optimized by BP neural network algorithm for the mixed spectral separation process. Thereby it can realize improving the recognition probability of camouflage target. Collecting the spectrum information in field of view (FOV) by the interferometer and linear array CCD detector, composing the set of mixed spectrum data, with known absorption spectrum of the material as a hidden layer of rules, it used BP neural network to separate the mixed spectrum data. Experiment with different distances, different combinations of mixed background spectrum as the initial data, using steel target (size: 1.5 m x 1.5 m) made of four kinds, the recognition probability of non-camouflage target is about 90% by BP neural network algorithm or the traditional algorithm, while the ...

2010-12-01

66

Two dimensional power spectral density measurements of X-rayoptics with the Micromap interferometric microscope  

Energy Technology Data Exchange (ETDEWEB)

A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's CCD camera. The correction function has only ...

2005-05-12

67

The design and performance of a capacitance sensor for two-phase flow concentration measurements in a square duct  

Energy Technology Data Exchange (ETDEWEB)

The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated for a stratified liquid ...

1995-12-31

68

The Magdalena Ridge Observatory 2.4 m Telescope  

Science.gov (United States)

EOS Technologies has been commissioned to design and build a unique 2.4m astronomical telescope for the Magdalena Ridge Observatory. This telescope utilizes a high quality primary mirror and cell from a now decommissioned military application. This paper describes the project and gives an overview of the telescope design. The Magdalena Ridge Observatory (MRO) 2.4 meter telescope will be primarily utilized to observe, track, and characterize solar system astronomical targets, Earth satellites, space vehicles, and terrestrial military targets. The telescope's rapid tracking (slew rates are 10o/sec) will allow it to move to any target and acquire data within one minute of receipt of notice. In this way, the telescope will be used to capitalize on targets of opportunity that occur in asteroid studies (e.g., Near Earth Objects) and in astrophysics, such as gamma ray bursts and other transient phenomena. Planned instrumentation includes a CCD imager, and a ...

2006-07-01

69

Short wave length and high qualification of free-electron laser  

International Nuclear Information System (INIS)

The oscillation experiment of free-electron laser (FEL) was carried at the wave length 488 nm. The space and time properties and power of FEL were investigated. The typical macropulse structure indicated the time interval 20 ms and the pulse width 2 to 3 ms. About 1 ns was necessary to build up FEL. The space distribution of FEL showed beautiful TEM_0_0 mode, TEM_0_1 and TEM_0_2 mode. On the basis of data, 39 #mu#W average power was calculated at 2.9 mA accumulated current per bunch by integrating each response of pixel of CCD camera. The peak power was 1.2 W. In the oscillator, FEL power was average 1.2 W, peak 38 kW. On the electron beam, the stability of head tail was controlled by 6-pole-Quadrupole-6-pole (SQS) system made by an experimental basis. We succeeded the single set test, setting up single set in the ring. The characteristic properties of electron beam evaporation mirror of photo oscillator were studied and then new type photo oscillator to obtain ...

1998-02-01

70

Research and development of neutron radiography in IAERU  

Energy Technology Data Exchange (ETDEWEB)

In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the main equipments for NR, the imaging apparatuses of cooled type CCD, SIT and superhigh sensitivity, the image processors of ...

1995-03-01

71

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a slope measurement of a ...

2008-07-14

72

Morphological classification and structural parameters for early-type galaxies in the Coma cluster  

CERN Document Server

We present the results of an isophotal shape analysis of three samples of galaxies in the Coma cluster. Quantitative morphology, together with structural and photometric parameters, is given for each galaxy. Special emphasis has been placed on the detailed classification of early-type galaxies. The three samples are: i) a sample of 97 early-type galaxies brighter than m_B = 17.00 falling within one degree from the center of the Coma cluster; these galaxies were observed with CCD cameras, mostly in good to excellent resolution conditions; ii) a magnitude complete sample of 107 galaxies of all morphological types down to m_B = 17.00 falling in a circular region of 50 arcmin diameter, slightly offcentered to the North-West of the cluster center; the images for this and the next sample come from digitized photographic plates; iii) a complete comparison sample of 26 galaxies of all morphological types down to m_R = 16.05 (or m_B \\simeq 17.5), also in a region of 50 ...

1995-01-01

73

Electrical resistivity and thermal expansion coeffcient of carbon-black-filled compounds around T_g  

International Nuclear Information System (INIS)

A Michelson interferometer and a CCD detector were used to measure the number of interference fringes related to the expansion length of rubber sample. The sample was situated in a microcryostat, and the temperature of the sample was varied from -200 .deg. C to +80 .deg. C. Various types of carbon black filled rubber (Duradene, Sn-SSBR) samples were used to determine the glass transition temperatures (T_g) and the thermal coeffcients (#alpha#). The mixing ratio was 0, 10, 30, 40, 50, or 70 parts per hundred of carbon black to Sn-SSBR rubber. For the unfilled rubber of Sn-SSBR, the T_g was about -24 .deg. C, and the thermal coeffcient was 1.18 X 10"-"4 .deg. C"-"1. The thermal coeffcients sharply increased around T_g for all samples, and decreased with increasing doping ratio of carbonblack from 0 .deg. C to 30 .deg. C. The volume resistivity was measured for natural rubber and EPDM rubber. They had maximum volume resistivities of 1.5 X 10"6 #OMEGA#m and 8.0 X 10"6 ...

2004-04-01

74

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

75

A heterogeneous dose distribution in simultaneous integrated boost: the role of the clonogenic cell density on the tumor control probability  

Energy Technology Data Exchange (ETDEWEB)

IMRT with inverse planning allows simultaneous integrated boost strategies that exploit the heterogeneous dose distribution within the planning target volumes (PTVs). In this scenario, the location of cold spots within the target becomes a crucial issue and has to be related to the distribution of the clonogenic cell density (CCD). The main aim of this work is to provide the means to calculate the optimal prescription dose in a relative inhomogeneous dose distribution. To achieve this, the prescription dose has to be assigned to obtain the same tumor control probability (TCP) as the ideal homogeneous distribution, taking into account different CCDs in different PTVs (i.e. visible and subclinical regions). An adapted formulation of the linear-quadratic model, within the F-factor formalism, has been derived to preserve a chosen TCP value for the whole target volume. The F-factor has been investigated to show its potential applications in clinical practice.

2008-10-07

76

Measuring q sub 0 using supernovae at z approx 0. 3  

Energy Technology Data Exchange (ETDEWEB)

The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should find one supernova in every 105--139 images (about two nights ...

1992-07-01

77

Families of ellipsoidal stellar systems adn the formation of dwarf elliptical galaxies  

International Nuclear Information System (INIS)

Core radii and central surface brightnesses of bulges and elliptical galaxies are measured using CCD photometry obtained with the Canada-France-Hawaii Telescope (scale = 0''.22 pixel"-"1; seeing = 0''.45--1''.0 FWHM). The correlations between core parameters are derived and compared for ellipticals, bulges, dwarf spheroidal galaxies, dwarf irregular galaxies, and globular clusters. The results are as follows. 1. Ihe data confirm the existence of well-defined correlations between the core parameters of elliptical galaxies. More luminous ellipticals have larger core radii r/sub c/ and lower central surface brightnesses #mu#/sub 0v/. Galaxies with larger core radii have larger central velocity dispersions. The small, bright core of M32 is normal for a galaxy of M/sub B/ = -15.2. Radio ellipticals and brightest cluster galaxies satisfy the correlations. 2. The bulges of disk galaxies are basically similar to elliptical galaxies. Their cores have slightly smaller r/sub ...

78

Computer vision algorithms in DNA ploidy image analysis  

Science.gov (United States)

The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate from the field of Mathematical Morphology, focusing on region-based watershed segmentation. First biomedical ...

2006-03-01

79

Biosorption of Cd(II), Ni(II) and Pb(II) from aqueous solution by dried biomass of aspergillus niger: application of response surface methodology to the optimization of process parameters  

Energy Technology Data Exchange (ETDEWEB)

In this study, the biosorption of Cd(II), Ni(II) and Pb(II) on Aspergillus niger in a batch system was investigated, and optimal condition determined by means of central composite design (CCD) under response surface methodology (RSM). Biomass inactivated by heat and pretreated by alkali solution was used in the determination of optimal conditions. The effect of initial solution pH, biomass dose and initial ion concentration on the removal efficiency of metal ions by A. niger was optimized using a design of experiment (DOE) method. Experimental results indicated that the optimal conditions for biosorption were 5.22 g/L, 89.93 mg/L and 6.01 for biomass dose, initial ion concentration and solution pH, respectively. Enhancement of metal biosorption capacity of the dried biomass by pretreatment with sodium hydroxide was observed. Maximal removal efficiencies for Cd(II), Ni(III) and Pb(II) ions of 98, 80 and 99% were achieved, respectively. The biosorption capacity of A. ...

2009-10-15

80

Laser: a Tool for Optimization and Enhancement of Analytical Methods  

Energy Technology Data Exchange (ETDEWEB)

In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation enables reliable determination of plume velocities even when ...

1997-01-01

 
 
 
 
81

Boundary Migration in Rutile  

Energy Technology Data Exchange (ETDEWEB)

TiO{sub 2} is a vital material in several technologies including, photocatalysis, gas sensing, biomaterials and optical coatings. Among the several crystal structures of this oxide, rutile has the highest density and microhardness, the highest index of refraction and the highest temperature stability. The processing of dense polycrystalline materials often includes the addition of a liquid-forming phase at higher temperatures. This technique is known as liquid-phase sintering and has been studied extensively. Rutile boundaries containing an amorphous phase have been used to study boundary migration and grain-boundary grooving. Visible-light (VLM), scanning electron (SEM) and transmission electron microscopy (TEM) in addition to electron-backscatter diffraction (EBSD) and a focused-ion beam (FIB) tool were used to characterize boundary migration in rutile. EBSD analysis was carried out on a Philips XL30 FEG SEM equipped with a DigiView 1612 high-resolution, high-speed ...

2003-08-01