The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.
The process of radiation induced electron capture by protons or deuterons producing new ultra low momentum neutrons and neutrinos may be theoretically described within the standard field theoretical model of electroweak interactions. For protons or deuterons in the neighborhoods of surfaces of condensed matter metallic hydride cathodes, such conversions are determined in part by the collective plasma modes of the participating charged particles, e.g. electrons and protons. The radiation energy required for such low energy nuclear reactions may be supplied by the applied voltage required to push a strong charged current across a metallic hydride surface employed as a cathode within a chemical cell. The electroweak rates of the resulting ultra low momentum neutron production are computed from these considerations.
Recently there has been growth, in interest in non-equilibrium interaction of half-period long optical pulses with matter. To date the optical pulses have been produced by chopping out a half-period long segment from a longer pulse using a semiconductor switch driven by a femtosecond laser. In this paper we present new methods for producing tunable ultra-short optical pulses as short as half an optical period using a free-electron laser driven by electron bunches with a duration a fraction of an optical period. Two different methods relying on the production of coherent spontaneous emission will be described. In the first method we show that when a train of ultra-short optical pulses as short as one half period. We present calculations which show that the small signal gain is unimportant in the early stages of radiation build up in the cavity when the startup process is dominated by coherent spontaneous emission. To support ...
Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.
Channel plasmon polaritons (CPPs) propagating along the bottom of subwavelength grooves cut into a metal surface were recently shown to exhibit strong confinement combined with low propagation loss, a feature that makes this guiding configuration very promising for the realisation of ultra-compact photonic components. Here, the results of our investigations of CPP guiding by V-grooves cut into gold are presented, demonstrating efficient large-angle bending and splitting of radiation as well as waveguide-ring resonators and Bragg grating filters.
Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and ...
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT ...
This short paper (abstract) describes the characteristics and performances of prototypes of ultra-thin lithium micro-batteries (thickness < 0.2 mm) which can be incorporated into microelectronic circuits. (J.S.)
This document presents the activity of KiloFarad International (KFI), a trade association for the promotion of the interests of the international ultra-capacitor industry through education and representation. KFI provides a forum for the ultra-capacitor industry to work on non-competitive activities (standards, working groups, test procedures etc..). The rest of the document presents some informations about ultra-capacitors technology and some advanced applications in the automotive and telecommunication industries. (J.S.)
Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials ...
Silicon carbide (SiC) based electronic devices are of great importance for applications under the condition of high temperature, high power and high radiation. Schottky diodes of Palladium/SiC are good candidates for hydrogen and hydrocarbon gas sensors at elevated temperature. The detection sensibility of the diodes has been found heavily temperature dependent. In this work, the electrical and chemical properties of Pd/SiC Schottky contacts were studied by XPS and AES at different annealing temperatures. Schottky diodes were made by depositing ultra-thin palladium films onto a silicon carbide substrate. No significant change in the Schottky barrier height of the Pd/SiC contact was found in the temperature range of 300-673K. Palladium diffusion into SiC and the formation of palladium silicides were observed at room temperature and became significant at 300^oC and higher temperature. The mechanism of diffusion and reaction at the Pd/SiC ...
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 by the irradiation. From these results we can find that ...
The 10.3-h /sup 165/Er, decaying by electron capture to stable /sup 165/Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in /sup 165/Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of /sup 169/Er and /sup 171/Er radioactive impurities in the reactor-produced /sup 165/Er sample are experimentally determined. Whole-body dose estimates for /sup 165/Er are given. These compare favorably with /sup 99/Tc dose.
The 10.3-h "1"6"5Er, decaying by electron capture to stable "1"6"5Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in "1"6"5Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of "1"6"9Er and "1"7"1Er radioactive impurities in the reactor-produced "1"6"5Er sample are experimentally determined. Whole-body dose estimates for "1"6"5Er are given. These compare favorably with "9"9Tc dose.
We present an approach for fabrication of intentionally positioned epitaxial InAs QDs in a micron sized light emitting diode. For site-selective growth, a combination of molecular beam epitaxy (MBE) and focused ion beam (FIB) implantation technology in an all-ultra-high-vacuum (UHV) setup has been employed. Single dot occupancy of almost 55 % on FIB patterned nano-depressions was successfully achieved. Thereafter, carrier injection and subsequent radiative recombination from the positioned InAs/GaAs self-assembled QDs was investigated by embedding these QDs in the intrinsic part of a GaAs-based micron sized p-i-n junction device. Few or single dot are expected to be electrically addressed in these devices. We report results from electroluminescence (EL) measurement which proves the single dot characteristics of our device. The EL spectra consist of sharp emission lines and their dependence on injection current shows linear behavior for exciton ...
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
The NREL Sensitized Solar Cell (SSC) Core Program supports the Solar America Initiative by: (1) targeting new devices and processes for commercialization by 2015 that are less expensive, more efficient, highly reliable, and environmentally benign; (2) collaborating with DOE OS/BES to conduct basic research targeting breakthroughs in key areas, such as ultra-high efficiency and/or ultra-low cost materials and devices.
This article described a full-scale green renovation project undertaken by a construction management firm in Newton, Massachusetts. Chapman Construction and Design began renovating its own office building in late 2007 and completed it in September 2008. The firm set out to achieve LEED Platinum certification from the United States Green Building Council. The project involved energy saving modifications to its mechanical systems; replacing plumbing fixtures with high efficiency alternatives to reduce water consumption by at least 40 per cent; installing skylights and additional windows to allow more natural light into the interior space; salvaging doors, lighting, metal studs and masonry whenever possible; and using sustainable products such as recyclable carpets, tiles and low-VOC paint. The main feature of the renovation was a new 47 kW (DC) photovoltaic (PV) solar power array installed on the rooftop. The PV array includes 208 panels and a SunPower SPR-225 system that produces 55,000 ...
A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...
This paper deals with an experimental study of ultra-precision diamond cutting of magnesium alloy (AZ31). In order to investigate the machinability such as the cutting force and the surface integrity and understand the problems in a micro cutting, the experiments on the diamond cutting of magnesium alloy and pure aluminum with an ultra-precision turning machine has been carried out. The machinability of magnesium alloy was compared with that of pure aluminum and discussed. Consequently, both the thrust force component and the surface roughness obtained by cutting of magnesium alloy became larger than that of pure aluminum. It was also found that the inclusions or the defects in the work material caused to generate the scratches on the finished surface and influenced the integrity of mirror surface. (orig.)
A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.
An Ultra-Low-Carbon 19% Cr-11% Ni Stainless Steels used in nuclear fuel reprocessing plants where highly corrosion resistance in nitric acid is required has been developed. This steel has optimized the chemistry composition to decrease inclusions and deformation-induced martensitic transformation. The formation of deformation-induced martensite has the potential danger of accelerating corrosion in nitric acid. In this paper, effects of cold reduction and martensitic transformation on corrosion resistance of Ultra-Low-Carbon Stainless Steels in nitric acid are discussed. The developed steel showed excellent corrosion resistance during long-term exposure to nitric acid. (author).
Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude density perturbation is assessed.
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic ...
Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is ...
The advanced technologies of Ka-Band systems such as high gain spot .... sometimes used based on link requirements for a specific application. .... received at NASA LeRC from a Ku-band satellite and retransmitted to the USAT at Ka-Band. .... and to the Office of Management and Budget, Paperwork Reduction Project ...
A railgun has an armature driven between two rail-like conductors. In other words, it is a linear drive device system that drives airframes by using the Lorentz`s force. The system is expected as a next-generation high-speed transport means, or as a means to create such ultimate fields as ultra-high pressures, ultra-high temperatures, and ultra-ferromagnetic fields. This paper is a report on investigations on the relevant technological trends as surveyed by the investigation committee at the Institute of Electrical Engineers of Japan using research reports published inside and outside the country. The reported themes cover explanations from the construction to the pulse power supply that forms the core of the technology, problems in switching, recent status of research and development, and to application fields. Compatibility in the high-level electrical and mechanical performances demanded in the railgun is not as easy as ...
In order to understand how matter 15 billion years ago in the form of quarks, gluons and leptons at a temperature of 2 (times) 10(sup 12) (degrees)K evolved to become today's Universe, the goal of relativistic and ultra-relativistic heavy ion physics is t...
BackgroundMimivirus, a giant dsDNA virus infecting Acanthamoeba, is the prototype of the mimiviridae family, the latest addition to the family of the nucleocytoplasmic...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
There is a growing interest in using {sup 242m}Am as a nuclear fuel. The advantages of {sup 242m}Am as a nuclear fuel derive from the fact that {sup 242m}Am has the highest thermal fission cross section. The thermal capture cross section is relatively low and the number of neutrons per thermal fission is high. These nuclear properties make it possible to obtain nuclear criticality with ultra-thin fuel elements. The possibility of having ultra-thin fuel elements enables the use of these fission products directly, without the necessity of converting their energy to heat, as is done in conventional reactors. There are three options of using such highly energetic and highly ionized fission products. - Using the fission products themselves for ionic propulsion. - Using the fission products in an MHD generator, in order to obtain electricity directly. - Using the fission products to heat a gas up to a high temperature for propulsion purposes. In this ...
The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of ...
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...
In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P{sup +}/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B{sup +} and BF{sub 2}{sup +} ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF{sub 3} as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit ...
In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P"+/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B"+ and BF_2"+ ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF_3 as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit coming from PLAD ...
Ultra-luminous infrared galaxies are among the most luminous objects in the local universe and are thought to be powered by intense star formation. It has been shown that in these objects the rotational spectral lines of molecular hydrogen observed at mid-infrared wavelengths are not affected by dust obscuration, leaving unresolved the source of excitation of this emission. Here I report an analysis of archival Spitzer Space Telescope data on ultra-luminous infrared galaxies and demonstrate that star formation regions are buried inside optically thick clouds of gas and dust, so that dust obscuration affects star-formation indicators but not molecular hydrogen. I thereby establish that the emission of H_2 is not co-spatial with the buried starburst activity and originates outside the obscured regions. This is rather surprising in light of the standard view that H_2 emission is directly associated with star-formation activity. Instead, I propose ...
The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V{sub GS} = V{sub DS}/2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted ...
The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V_G_S = V_D_S/2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted in ...
A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous energy Monte Carlo calculations. It was confirmed that ...
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B{sub 2}H{sub 6} plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B{sub 2}H{sub 6} plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for ...
We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B_2H_6 plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B_2H_6 plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for high-speed application ...
Tailor die quenching in the hot stamping of quenchable steel sheets was developed to produce ultra-high strength steel formed parts having strength distribution. Local portions of the heated sheet were quenched by holding grooved tools at the bottom dead centre during the stamping. Non-contact portions were generated in the sheet by grooving the tools, and thus the strength in the contact portions is high owing to the quenching and that in the non-contact portions is low owing to the lack of the quenching. Hat-shaped products having a tensile strength of approximately 1.5GPa only at four corners were formed.
Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint.
A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.
A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.
The conventional Calzination-Reduction-Carburization (CRC) process offers the potential to manufacture commercial WC powders with median SEM grain sizes below 0.5 pm (ultra fine grades). Strict process control and a high degree of automation have led to increased powder uniformity and high lot-to-lot reliability. The high potential and flexibility of the CRC process is shown by the development of tailor made WC powders with regard to subsequent alloy manufacturing. R and D powders have successfully been processed in full-scale units exhibiting SEM grain sizes of 0.15 - 0.20 pm. This paper discusses the powder characteristics of various ultra fine WC powder grades, stemming from the conventional CRC process. Analytical characterization include also field-emission SEM, bright field TEM, EDX analysis and XRD-line broadening. (author)
Mechanical properties of P-LDHA and V-ROL N steels of the Czech production are compared with other ultra-high strength steels produced in the world. The most important results can be summarized into following points: 1. Optimally heat treated P-LDHA steel exhibits substantially better strength characteristics then the V-ROL N steel. 2. Optimal tempering temperature of the P-LDHA steel is 300 C. 3. Basic mechanical properties of P-LDHA steel belong to the top of the UHS steels ranking and are well comparable with those of American 300 M steel. 4. In the low-cycle fatigue region, the P-LDHA steel exhibits slightly better fatigue resistance then the 300 M steel. On the other hand, the high-cycle fatigue resistance of 300 M steel is slightly better then that of the P-LDHA steel. (orig.)
This paper describes how hydrogen transport affects the severity of hydrogen embrittlement in 300 M and AerMet100 ultra high strength steels. Slow strain rate tests were carried out on specimens coated with electrodeposited cadmium and aluminium-based SermeTel 1140/962. Hydrogen diffusivities were measured using two-cell permeation and galvanostatic charging methods and values of 8.0 x 10{sup -8} and 1.0 x 10{sup -9} cm{sup 2} s{sup -1} were obtained for 300 M and AerMet100, respectively. A two-dimensional diffusion model was used to predict the hydrogen distributions in the SSR specimens at the time of failure. The superior embrittlement resistance of AerMet100 was attributed to reverted austenite forming around martensite laths during tempering.
We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.
In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.
Bacterial cellulose produced by the gram-negative bacterium Gluconacetobacter xylinum was found to be an excellent native starting material for preparing shaped ultra-lightweight cellulose aerogels. The procedure comprises thorough washing and sterilization of the aquogel, quantitative solvent exchange and subsequent drying with supercritical carbon dioxide at 40 degreeC and 100 bar. The average density of the obtained dry cellulose aerogels is only about 8 mg cm-3 which is comparable to the most lightweight silica aerogels and distinctly lower than all values for cellulosic aerogels obtained from plant cellulose so far. SEM, ESEM and nitrogen adsorption experiments at 77 K reveal an open-porous network structure that consists of a comparatively high percentage of large mesopores and small...
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...
The interpretation of solution hydrodynamic data in terms of macromolecular structural parameters is not a straightforward task. Over the years, several approaches have been developed to cope...Full Text Available
High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)
A cell calculation code SLAROM-UF was developed to improve calculation accuracy of effective cross sections for various fast reactor types. SLAROM-UF has a capability to calculate effective cross sections in ultra fine groups of about 100,000 below 50keV and in fine groups above the energy (maximum 900 groups). Resonance interaction among the fuel, the coolant, and the structure materials can be treated accurately even in a heterogeneous cell structure. Temperature can be set up freely in a cell by the ultra fine group calculation. Improvement in nuclear characteristics was observed in the analysis of JUPITER critical experiment, as 0.1% for criticality, 4% for sodium void reactivity, several % for radial reaction rate distribution, when SLAROM-UF was used instead of the typical cell calculation code. The effect of the ultra fine group calculation is remarkable in the non-leakage term of sodium void reactivity, and that of ...
Overcoming the limiting constraints of stimulated Raman scattering (SRS) and stimulated Brilluoin scattering (SBS) poses serious fibre design challenges for increasing the output power of optical amplifiers and lasers. New fibre amplifier designs are proposed to break out of these limitations to reach several kWs CW powers. (Author)
The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.
By means of an audio frequency plasma polymerisation ultra-thin gradient plasma polymer layers were deposited on zinc and zinc-coated iron. The aim was to generate an interfacial polymeric layer which bonds to an oxidised metal as well as to a subsequently applied organic coating and acts as an interfacial barrier layer for ions and water. Surface modifications were done in an in situ plasma cell with infrared reflection absorption spectroscopy (IRRAS). The zinc surface was first activated by an oxygen plasma to provide a freshly oxidised and contamination free oxide surface. The intermediate stages of the surface reactions could be revealed. Carbon dioxide molecules as oxidation products adsorbed on the growing zinc oxide and were desorbed at a later stage. An organosilicon plasma polymer was deposited directly on top of the oxide layer from a hexamethyldisilane (HMDS) plasma. Afterwards a cyclohexene (CHEX)/hexamethyldisilane co-plasma polymer was deposited. The ...
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.
A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].
An 'electron-bridge' mechanism of nuclear reaction in an atom or ion by ultra-intense laser fields is presented. A preliminary estimate of the intensity dependence of the rate of disintegration reaction of deuteron nucleus in deuterium atom is made for 800 nm laser fields. For intensities below 5x1021 W/cm2, the rate of disintegration by the 'electron-bridge' mechanism is found to be small, but it rises sharply and becomes large already for ?1022 W/cm2.
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
This report summarizes the findings of a five-month LDRD project funded through Sandia's NTM Investment Area. The project was aimed at providing the foundation for the development of advanced functional materials through the application of ultrathin coatings of microporous or mesoporous materials onto the surface of substrates such as silicon wafers. Prior art teaches that layers of microporous materials such as zeolites may be applied as, e.g., sensor platforms or gas separation membranes. These layers, however, are typically several microns to several hundred microns thick. For many potential applications, vast improvements in the response of a device could be realized if the thickness of the porous layer were reduced to tens of nanometers. However, a basic understanding of how to synthesize or fabricate such ultra-thin layers is lacking. This report describes traditional and novel approaches to the growth of layers of microporous materials on silicon wafers. The ...
This paper describes high speed rolling and gauge control in cold tandem mill for ultra-thin gauge strip at the Chiba Works of Kawasaki Steel Corporation. To improve the plate-out property of rolling oil, cationic polymeric coagulant was prepared. Rolling oil with cohesion independent of inorganic inclusions or phosphatide was developed, to improve the lubrication for cold rolling, remarkably. In addition, a low-cost Ti-enhanced work roll having high wear resistance and excellent grindability was developed. Rolling can be conducted at the optimal rolling roughness and operation can be performed at the highest rolling speed independent of the rolling treatment amount. Rolling speed at 2800 m/min was confirmed by developing the rolling oil with excellent lubrication and the work roll having high wear resistance. For the improvement of strip thickness accuracy at the steady state rolling, use of the backup roll as roller bearing was more effective rather than the ...
Potassium atoms in selected high-lying np Rydberg states (80 #<=# n #<=# 400) are being used as a tool to examine electron-polar molecule collisions at ultra-low energies (#approx#80 #mu#eV - 1 meV). This energy regime has not been investigated previously and is of interest because the corresponding electron de Broglie wavelength is large, #approx#1300 - 330 Angstrom, and because the collision time is comparable to the period of molecular rotation. A variety of target molecules has been studied, including simple rotors such as HF, and more complex species such as NH_3, CH_3I, CH_2Br_2 and C_6H_5NO_2. These targets encompass a range of dipole moments and rotational behavior, but analysis of the data shows that in each case the cross section #sigma#(#epsilon#) for rotationally-inelastic electron-polar molecule scattering varies approximately as 1/#epsilon# where #epsilon# is the electron energy. Such threshold behavior is not predicted by the Born approximation ...
Fluorine is known to have a beneficial role for the B diffusion reduction in preamorphized Si, and is promising for the realization of ultra-shallow junctions. Thus, we studied the F incorporation in Si during the solid phase epitaxy (SPE) process, pointing out the effects of the implanted F energy and fluence and the role played by the possible presence of dopants. The incorporation of fluorine proceeds by F segregation at the amorphous-crystalline interface, with a kinetics driven by the SPE rate. In fact, the quicker the SPE rate, the higher is the F fluence retained. Moreover, we demonstrated that F incorporated in Si layers does not appreciably affect the Is emission from spatially separated end-of-range (EOR) defects. The modification, induced by the presence of F, of the point defect density (Is and Vs) was also studied by means of B and Sb spike layers, used as local markers for Is and Vs, respectively. We showed that F is not only able to completely ...
In an attempt to enhance the electrical and mechanical properties of the high temperature superconducting oxides, high T(sub c) composites were prepared composed of the 123 compounds and AgO. The presence of extra oxygen due to the decomposition of AgO at high temperature is found to stabilize the superconducting 123 phase. Ag is found to serve as clean flux for grain growth and precipitates as pinning center. Consequently, almost two orders of magnitude enhancement in critical current densities were also observed in these composites. In addition, these composites also show much improvement in workability and shape formation. On the other hand, proper oxygen treatment of Y5Ba6Cu11Oy was found to possibly stabilize superconducting phase with T(sub c) near 250 K. I-V, ac susceptibility, and electrical resistivity measurements indicate the existence of this ultra high T(sub c) phase in this compound. Detailed structure, microstructure, electrical, magnetic and thermal ...
We have investigated and modeled the boron diffusion in silicon following ultra-low-energy implantation (500 eV). It is well known that reducing implant energies is an effective way to eliminate transient enhanced diffusion due to the excess of interstitials from the implant. However, for sub-keV B implants diffusion remains enhanced. This enhancement is linked to the presence of a silicon boride layer located at the silicon surface which creates interstitials. This phenomenon is named 'boron enhanced diffusion' (BED). The BED effect is of obvious interest since it counteracts the advantage obtained by reducing the ion implantation energy. For these reasons, we have investigated the diffusion of low-energy boron implanted in crystalline silicon and tested a complete simulation program, which takes into account the effect of boron precipitation and the effect of the silicon boride layer as a source of self-interstitials. Experimental results have ...
Supermetal with critical characteristics is under advanced investigation for further improvement of metal materials. Although iron is most frequently used as structural material among various metals, it should be used more carefully and effectively because of resource limitation and global environmental problem. It is essential to draw various excellent properties much more from iron and to improve recyclability. In particular, the best way to meet these requirements is achievement of more fine structure and higher purity. Since the lowest crystalline grain size is now limited to nearly 10{mu}m, metallic structure composed of grains below 1{mu}m is expected by mesoscopic control. Various methods have been studied to achieve ultra-fine crystalline structure, and study of precise heat treatment control and ultra-strength metallurgy is required. Heat treatment in magnetic field and layered structure by mechanical alloying are also promising. ...
Gamma-ray burst (GRB) is one of the candidates of high-energy cosmic-ray acceleration sites. They may be also ultra-high-energy (above 3 EeV) cosmic-ray (UHECR) sources. In this paper, we discuss possibilities and implications of high-energy cosmic-ray acceleration in GRBs. (1) First, we show that not only protons but also heavier nuclei can be accelerated up to ultra-high energies in both usual high-luminosity (HL) and low-luminosity (LL) GRBs by using the Geant4. LL GRBs may also make a significant contribution to the observed UHECR flux if they form a distinct population, and we investigate cosmic-ray acceleration in LL GRBs in detail. (2) Second, we discuss implications of the GRB-UHECR hypothesis (and Hypernova-UHECR hypothesis) to cosmic-ray astronomy. HL GRBs and LL GRBs will lead to different source number densities as UHECR sources, so that the determination of the number density of UHECR sources and strength of the mean extragalactic ...
Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which may be related to ...
A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated damage. (au)
In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that the ...
In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that the ...
Experimental discussions were given on effect of V and W addition on the high temperature strength properties of 12% Cr-15% Mn austenite steels. The test samples were added with W at 0% to 3.5% and V at 0% to 0.5% in addition to C and N, and were given aging treatment or solution treatment. This paper describes the following matters on the results of high-temperature strength measurements and structural observation: A remarkable trend was observed that M23 Cb type carbides precipitate in the aging treatment, wherein aging hardening appears prominently which is attributable to ultra-fine deposits of vanadium nitride (VN) in the V-added material; the V addition is very effective in increasing the high-temperature tensile strength and creep fracture strength as compared with single W addition, wherein the said carbides that accelerate the precipitation as a result of the V addition make a large contribution, in addition to that by ultra-fine VN ...
In the development of the specific mathematical modeling for heavy and ultra heavy petroleum fractions in a molecular distiller is very important the definition of physical and chemical parameters as density and specific heat of the mixture, the enthalpy of vaporization, among others, since they are used in the energy balance. Information on these properties and their variation with temperature are found in the open literature for mixture with few components (simple mixtures). However, for multicomponent solutions consisting of complex mixtures such as oil and its heavy and ultraheavy fractions, available data are few, or are limited to low temperatures. The specific heat is an important property in the energy balance. This property can be measured by Differential Scanning Calorimetry (DSC), which gives results with great sensitivity and accuracy. This paper presents the variation of specific heat with the temperature of ultra-heavy oil ...
In this work we present an ultra-low temperature method for the oxidation of an amorphous silicon-carbide-nitride (SiCN) material. The SiCN is deposited on silicon substrates by plasma enhanced chemical vapor deposition using CH{sub 4}, SiH{sub 4}, and N{sub 2} chemistry. The physical and chemical properties are characterized for the as-deposited SiCN and post-oxidized films are discussed. The SiCN film is exposed to oxygen plasma, where it undergoes a chemical transformation into a binary SiO{sub 2} material system. A 1.7 nm/min oxidation rate is typical for this process and compares favorably to oxidation methods utilizing much higher temperatures. The substrate temperature remains extremely low throughout the oxidation process, T{sub s} < 200 deg. C. Changes in film stress, optical constants, film thickness, surface roughness, and film density are measured. Chemical analysis by X-ray photoelectron spectroscopy is reported for both the as-deposited and ...
We report measurements for coherent rho^0 production, AuAu->AuAu rho^0, and coherent rho^0 and e^+e^- pair production accompanied by mutual nuclear Coulomb excitation, AuAu->Au*Au* rho^0 and AuAuee, in ultra-peripheral relativistic gold-gold collisions (UPC). We discuss transverse momentum, mass, and rapidity distributions. The two photon-process of e^+e^- pair production is an important probe of strong field QED because of the large coupling Z*alpha=0.6. At sqrt{s}=200GeV, the e^+e^- production cross section agrees with lowest order QED calculations. The cross sections for coherent rho^0 production at sqrt{s}=130 and 200GeV are in agreement with theoretical predictions. The calculations for both, coherent e^+e^- and rho^0 production treat nuclear excitation as independent process.
An extremely sensitive stripping voltammetric procedure for ultra-trace determination of iridium(III) is reported. The method is based on the interfacial accumulation of the iridium(III)-CTAB complex onto the glassy carbon electrode, followed by the catalytic reduction of the adsorbed complex in the presence of bromate. 0.3molL^-^1 acetate buffer pH 4.7+6.9x10^-^2molL^-^1 NaBrO3+2.7x10^-^5molL^-^1 cetyltrimethylammonium bromide (CTAB)+0.2molL^-^1 KCl was employed as the supporting electrolyte. The analytical procedure was verified by the analysis of the standard reference materials: Sea Water BCR-CRM 403 and Fresh Water NIST-SRM 1643d. The accuracy, expressed as relative error e%, was satisfactory, being lower than 6%, while precision as repeatability, expressed as relative standard deviat...
The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified version of the well known Electromagnetic ...
T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic advantages for MRT. (orig./MG).
The main driver in ultra-shallow formation for the 65 nm technology node and beyond is to find solutions that both reduce boron transient enhanced diffusion and can be integrated in the CMOS process flow. To this end, many studies have recently focused on using co-doping techniques with fluorine and most recently with carbon. In most cases, one or both of these is co-implanted with a dopant specie in pre-amorphized silicon. In this work, we show a comparative study of fluorine or carbon co-implanted with low-energy boron to form source and drain extension junctions for PMOS devices. We will show that by a systematic optimization of germanium, boron, fluorine or carbon energies and doses, spike annealing technology can be extended to the 65 nm node. These results will be used to discuss how the different formed junctions offer potential solutions for either low-power or high-performance PMOS device fabrication.
Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery is very desirable. Typically, this imagery has many thousands of pixels on a side and is characterized by lower resolutions (e.g. {approx}0.5 meters/pixel to {approx}2.0 meters/pixel) and lower frame rates (e.g. {approx} sub-Hz to several Hz). We describe our ultra-scale capable implementation of a multiple-vehicle tracking algorithm for overhead persistent surveillance imagery. This work builds upon an earlier report, where now the algorithm has been modified for improved performance and has been substantially improved to handle much larger datasets in a much shorter time.
A nuclear battery based on the direct energy conversion of the fission products is presented. Such energy conversion is possible by using a nuclear reactor with ultra-thin fuel elements of 0.2 {mu}m of {sup 242m}Am. The amount of nuclear fuel is 376 g and the dimensions of the battery are 2.4x2.4x2.4 m{sup 3} (including the vacuum spacing), with a BeO moderator and Be electrodes. The total power of the reactor is 10.6 MW and the electrical power is 0.652 MW.
There is growing interest in using {sup 242m}Am as a nuclear fuel for space reactors and nuclear batteries. In this paper, we discuss different {sup 242m}Am enrichments, as well as fuel weight requirements, to produce a critical reactor. It was found that relatively low enrichments of {sup 242m}Am, about 10 w/o, are enough to guarantee criticality. Such low enrichments might eliminate the need for a {sup 242m}Am enrichment process. It was also found that the best results for low {sup 242m}Am requirements are obtained with a moderator to fuel volume ratio of 10,000.
This is a study done in collaboration with Deidre Hunter at Lowell Observatory studying star formation in two luminous spiral galaxies NGC 801 and UGC 2885. We used ultra-deep H? images taken at the KPNO 2.1 m telescope. We compare these data to stellar images at various wavelengths and to HI maps to determine the extent of star formation activity into the outer disk in these galaxies and its relationship to the gas and older stars. TW is grateful for an REU internship during the summer of 2010 at Northern Arizona University, funded by NSF through grant AST-1004107.
Energy deposition process by relativistic fast electrons produced by ultra-intense laser pulses is discussed. The process is calculated with a two dimensional Fokker-Planck simulation code including binary and collective collisions coupled with electromagnetic field. We focused on Velocity Distribution Function (VDF) dependence in the simulation. The results show that the spread angle of the fast electrons distribution affects energy deposition area and deposited energy is concentrated in the vicinity of the propagation axis of the fast electrons. It may be also suggested that self-pinch effect of a fast electron beam causes large deposition energy. (author)
This feature articles described a concept and technical problems of geological disposal of high-level radioactive waste in the civil engineering. It consists of six papers such as the present statues and subjects of geological disposal by KITAYAMA Kazumi, the diastrophism, igneous activity, and upheaval and erosion by YAMAZAKI Haruo, the groundwater flow and evaluation of nuclear transfer by IJIRI Yuji, evaluation of alteration of cement materials in the ultra-long period by HAGA Kazuko, The Mizunami Underground Research Laboratory in course of construction by SAKAMAKI Masanori, and interview of the ninetieth president of JSCE (Japan Society of Civil Engineers), he places his hope on JSCE and civil engineers by KISHI Kiyoshi. (S.Y.)
Zeolite Y is the active component of most commercial cracking catalysts. Interaction of H[sub 3]PO[sub 4] with extraframework aluminum of ultra-stable zeolite (USY) leads to the formation of different types of aluminum phosphates, while there is no indication of the formation of SAPO zeotype structures. The total acidity of USY slightly decreases upon the H[sub 3]PO[sub 4] treatment, while the maximum in the distribution of acid strength is shifted to milder acidities. Dealumination of the zeolite and creation of POH sites associated with AIPO[sub 4] are responsible for the modifications observed. 37 refs., 8 figs., 3 tabs.
We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.
In this paper it is described how a martensitic steel sheet with tensile strength of 1400 MPa is heat treated locally. The sheet is then formed in the heat treated regions in a way that would be impossible with the untreated material. Mechanical properties and forming limit diagrams of the heat treated material are determined and the forming operations are simulated, which shows that the method can be used by designers. Although the method has been known for decades, it remains to be industrialised and the work presented here is to be seen as a contribution to this development. (orig.)
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of absorption and desorption systems can be ...
In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.
When searching for anisotropies in the arrival directions of Ultra High Energy Cosmic Rays, one must estimate the number of events expected in each direction of the sky in the case of a perfect isotropy. We present in this article a new method, developed for the Auger Observatory, based on a smooth estimate of the zenith angle distribution obtained from the data itself (which is essentially unchanged in the case of the presence of a large scale anisotropy pattern). We also study the sensitivity of several methods to detect large-scale anisotropies in the cosmic ray arrival direction distribution : Rayleigh analysis, dipole fitting and angular power spectrum estimation.
It is shown that all contracting, spatially homogeneous, orthogonal Bianchi cosmologies that are sourced by an ultra-stiff fluid with an arbitrary and, in general, varying equation of state asymptote to the spatially flat and isotropic universe in the neighbourhood of the big crunch singularity. This result is employed to investigate the asymptotic dynamics of a collapsing Bianchi type IX universe sourced by a scalar field rolling down a steep, negative exponential potential. A toroidally compactified version of M*-theory that leads to such a potential is discussed and it is shown that the isotropic attractor solution for a collapsing Bianchi type IX universe is supersymmetric when interpreted in an 11-dimensional context.
It is reported about the adsorptive stripping voltammetric determination of uranium, antimony, tin, vanadium and molybdenum using chloranilic acid as complex forming reagent. The determination limits are in the l{sup 1}-range. (orig.) [Deutsch] Es wird ueber die Bestimmung von Uran, Antimon, Zinn, Vanadium und Molybdaen durch Adsorptions-Stripping-Voltammetrie mit Chloranilsaeure als Komplexbildner berichtet. Die Bestimmungsgrenzen liegen im ng l{sup -1} Bereich. (orig.)
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...
Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and ...
Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, found at surfaces of ...
Current dewatering methods for ultra-fine coal suspensions are inadequate and usually require subsequent expensive thermal drying. This unique dewatering method is based on pressurized electroosmosis, the movement of water by an electrical field through a porous medium, under modest pressure, e.g., 110 psi. More ultra-fine coal can be utilized since an effective dewatering process can be realized by combining known filtration techniques with electroosmosis. The dewatering efficiency can be significantly improved, the residual moisture of the cake can be substantially reduced and handling problems can be eliminated. Bench-scale testing is being used to optimize the parameters which influence pressurized electroosmotic dewatering (PED) of ultra-fine coal suspensions. Particle size distribution is being addressed to obtain a maximum density for a given pressure such that pore saturation is maintained allowing electroosmosis to ...
The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).
The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.
drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...
...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...
... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...
When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...
... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
The following topics are discussed: insertion of incorrect bases in DNA; ability of DNA polymerase to copy uv-irradiated DNA; role of enzymes in repair of DNA; effects of uv radiation on molecular weight of DNA; photoreactivation; repair of DNA in Escherichia coli and xp cells following uv radiation; and synchrotron radiation studies on DNA repair. (HLW)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).
BackgroundTo compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated...Full Text Available
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge ...
The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking into account the effect of the field on ...
The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...
Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as ...
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation. (author).
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)
The methods introduced for the field of cleaning waste water can be classified under various processes. Chemical oxidation is done with ozone, hydrogen peroxide and ultraviolet irradiation with subsequent biological decomposition. Another method is ultra-filtration with recovery of valuable materials or waste water ponds with algae biomass to decompose ammonium compounds, nitrates and phosphates. (EF) [Deutsch] Die auf dem Gebiet der Abwasserreinigung vorgestellten Methoden kann man in verschiedene Verfahren einordnen. Die chemische Oxidation erfolgt mit Ozon, Wasserstoff-Peroxid, UV Bestrahlung und anschliessenden biologischen Abbau. Eine andere Methode ist die Ultrafiltration mit Rueckgewinnung von Wertstoffen oder Abwasserteiche mit Algenbiomasse zum Abbau von Ammoniumverbindungen, Nitraten und Phosphaten. (EF)
The formation, migration and agglomeration in silicon of fluorine-vacancy complexes have been monitored by single-detector Doppler broadening spectroscopy. After electronics engineers found that fluorine ion implantation effectively eliminated the transient-enhanced diffusion of dopants in the creation of ultra-shallow junctions, a vital step in the further miniaturization of device structures, positron beams have played a pivotal role in providing an insight into the mechanisms underlying this phenomenon, being able to detect FV complexes in implanted and annealed samples. Secondary Ion Mass Spectrometry has provided complementary information on fluorine concentrations so that the nature of the F{sub m}V{sub n} complexes can be further assessed. New results on Si and SiGe structures are presented.
Faserbewehrter Beton wird heute zunehmend auch bei Tunnelbauwerken (Tunnelinnenschalen, Tubbinge) eingesetzt. Wesentliche Vorteile sind das hohe Tragvermogen, das daraus entstehende Einsparungspotential an herkommlicher stabformiger Bewehrung (Biegebewehrung, Bugelbewehrung in der Randzone), die Aufnahme von Spaltzugbeanspruchungen durch die Fasern, Rissbreitenbegrenzung, erhohte Dauerhaftigkeit, verbesserter Brandwiderstand (insbesondere bei Verwendung von Kunststofffasern), Optimierung der Arbeitsablaufe etc. Neue Entwicklungen in der Betontechnologie haben in den letzten Jahrzehnten den faserbewehrten ultrahochfesten Beton (engl. UHPFRC - Ultra High Performance Fibre Reinforced Concrete) hervorgebracht. Im Rahmen dieser Arbeit wird der Einsatz des ultrahochfesten, stahlfaserbewehrten Be...
The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.
A new high strength titanium alloy has been developed primarily intended for fastener applications. While Ti-6Al-4V is used extensively as a fastener alloy in the aerospace industry, its shear strength allowable is limited to 655 MPa (95 ksi). For higher shear strength requirements, various steels or nickel-based alloys are used (up to 860 MPa (125 ksi)), but with the attendant density penalty. This new alloy is intended to provide the 860 MPa shear strength at roughly a 40% weight savings. After screening various alloy systems, the optimum chemistry has been selected as follows: Ti-6.0V-6.2Mo-5.7Fe-3Al. In light of its 125 ksi shear strength goal, the alloy has been designated TIMETAL reg-sign 125.
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
The conductive ultra thin films were fabricated from mixed monolayers containing stearic acid and Head-to-Tail poly(3-alkylthiophene). These films exhibited well-defined layered structures as determined by optical absorption and X-ray diffraction measurements. The UV-Vis absorption spectra of these films showed lower energy absorption shifts of 48 nm from that of the random poly(3-alkylthiophene)/stearic acid LB films. The blue shift of absorption maximum of the LB film is attributed to the increase of {pi}-conjugation length caused by no steric hindrance of alkyl side chains. The conductivity of the Head-to-Tail poly(3-hexylthiophene)/stearic acid LB films was greatly improved in the range of 67-100 S/cm. (orig.)
The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).
Accelerator mass spectrometry (AMS) represents a powerful technique for the detection of long-lived radionuclides through ultra-low isotope ratio measurements. In many cases, counting atoms rather than decays yields much higher sensitivities. The potential of AMS will be demonstrated on typical radionuclides of interest with half-lives between some tens of years up to a hundred million years. The precise measurement of the 27Al(n,2n)26Al excitation function will be exemplified. Lack of information exists for a list of nuclides as pointed out by nuclear data requests. A brief overview on detection limits and some applications for selected long-lived radionuclides is given.
After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.
A dense Pd-Ag membrane reactor (MR) with 100% hydrogen selectivity packed with either Rh/La2O3 or Rh/La2O3-SiO2 as catalysts was used to carry out the dry reforming of methane. The membrane reactor simulation was performed using a well-known reactor model. For this purpose, we employed the equations derived from complete kinetic studies of the dry reforming of methane reaction in connection with both catalysts. In addition, we developed the kinetic equation for the reverse water gas shift reaction (RWGS). The combination of detailed kinetic studies with the measured permeation flux for the Pd-Ag membrane allowed a complete comparison between experimental and simulated operation variables. The variables studied for both catalysts were methane conversion and hydrogen permeation as a function...
Pre-amorphization of ultrashallow implanted boron in Silicon-on-insulator is optimized to produce an abrupt box-like doping profile with negligible electrical deactivation and significantly reduced transient enhanced diffusion. The effect is achieved by positioning the as-implanted amorphous/crystalline interface close to the buried oxide interface, to minimize interstitials whilst leaving a single-crystal seed to support solid-phase epitaxy. Based on a simple physical model of our results, we estimate that the interface between the Si overlayer and the buried oxide is an efficient interstitial sink with a recombination length of the order of 10nm or less under our experimental conditions. (author)
The roughness length at air-sea interface during free convection (Z0fc) is mainly related to the convective velocity (w) rather than the friction velocity (u). The parameterization of Z0fc with (w)2/g as proposed by Abdella and D'Alessio (2003) is evaluated. It is shown that the field measurements at MM Lab, Tarapur Maharashtra Site (TMS) coastal site using Metek GmbH, Ultra sonic anemometers are consistent with the proposed formula. In order to avoid self-correlation by using u, a new parameterization of w with ?u and ?v and gustiness parameter as given by Fairall et al. (1996) is used. The mean values of w and Z0fc estimated using new parameterization were observed to be 0.97 m/s and 2.3E-4 m respectively for the year 2009 at TMS. (author)
Availability of a natural gas-powered van that meets California`s ultra low emission vehicle requirements and has a 300-km range was reported. A similar van with an electric system giving a range of 240 km was also within sight. Regarding the limitations of electric batteries it was suggested that a super capacitor may allow systems to achieve higher energy densities; a refuelable zinc-air battery could be considered for vehicle use. While the prospect for emissions improvement of gasoline vehicles has clearly improved in recent years, the relative costs of infrastructure, vehicle and fuel for the the alternative fuels compared with gasoline demonstrate the difficulty the alternative fuels have in taking market share from gasoline. For the next decade, gasoline, propane and CNG are expected to be the dominant fuels for vehicles. After that, the leading fuel will be the one that has been most extensively researched and developed during the decade. 17 refs.
Protein motions on all timescales faster than molecular tumbling are encoded in the spectral density. The dissection of complex protein dynamics is typically performed using relaxation rates determined at high and ultra-high field. Here we expand this range of the spectral density to low fields through field cycling using the nucleocapsid protein of the SARS coronavirus as a model system. The field-cycling approach enables site-specific measurements of R{sub 1} at low fields with the sensitivity and resolution of a high-field magnet. These data, together with high-field relaxation and heteronuclear NOE, provide evidence for correlated rigid-body motions of the entire {beta}-hairpin, and corresponding motions of adjacent loops with a time constant of 0.8 ns (mesodynamics). MD simulations substantiate these findings and provide direct verification of the time scale and collective nature of these motions.
Nanowires, films, and membranes comprising ordered porous manganese oxide-based octahedral molecular sieves, and methods of making, are disclosed. A single crystal ultra-long nanowire includes an ordered porous manganese oxide-based octahedral molecular sieve, and has an average length greater than about 10 micrometers and an average diameter of about 5 nanometers to about 100 nanometers. A film comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is stacked on a surface of a substrate, wherein the nanowires of each layer are substantially axially aligned. A free standing membrane comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is aggregately stacked, and wherein the nanowires of each layer are substantially axially aligned.
Ultra-thin, uniform, pinhole-free solid polymer electrolyte films having a fixed carboxylic ester group of approximately 1 {mu}m thickness were prepared by polymerization of methyl acrylate and tris(2-methoxyethoxy)vinylsilane in a glow discharge plasma. The carboxylic ester group of the plasma polymer were transformed to lithium carboxylate groups by treatment with lithium iodide. This process give a single lithium ion conductive film. These solid polymer electrolyte films showed ionic conductivities of the order of 10{sup -8} S cm{sup -1} (10{sup 4} {omega} cm{sup 2} resistance per unit area) at room temperature. (orig.).
ABSTRACT New observations from the Hubble Ultra Deep Field suggest that the star formation rate at Formula Not Shown drops off faster than previously thought. Using a newly determined star formation rate for the normal mode of Population II/I (PopII/I) stars, including this new constraint, we compute the Thomson scattering optical depth and find a result that is marginally consistent with Wilkinson Microwave Anisotropy Probe 5 results. We also reconsider the role of Population III (PopIII) stars in light of cosmological and stellar evolution constraints. While this input may be needed for reionization, we show that it is essential in order to account for cosmic chemical evolution in the early universe. We investigate the consequences of PopIII stars on the local metallicity distribution fu...
The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional and multi-component seismic area is being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with extended-reach jetting lance and other ultra-short radius lateral technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil-in-place will result in additional oil production by primary and enhanced recovery processes.
The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in Red River and Ratcliffe shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing three-dimensional and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with extended-reach jetting lance and other ultra-short-radius lateral technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil in place will result in additional oil recovery by primary and enhanced recovery processes.
The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in Red River and Ratcliffe shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing three-dimensional and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with extended-reach jetting lance and other ultra-short-radius lateral technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil in place will result in additional oil recovery by primary and enhanced recovery processes.
In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.
The automotive industry desires to optimize safety and lightweight construction for the production of cars and trucks. The resulting task for steel suppliers is to make steel grades available that can fulfil these requirements. Different projects have shown optimistic outlooks for optimization of safety and reduction of the weight of automobile bodies by using different high strength and ultra high strength steels. In the last group the dual phase steels play the lead. In recent years different steel grades have been developed and optimized for these applications. On one hand developing the mechanical properties as well as joining and forming of dual phase steels is one of the first steps. On the other hand different coated surfaces for various applications of dual phase steels is another step. Starting with characteristic production conditions for cold rolled hot dip galvanised dual phase steels, the mechanical properties for joining and forming will be deduced ...
Discovery of better biomarkers for diagnosis, prognosis, and therapy-response prediction is the most critical task of a scientific quest aimed at developing newly designed, tailor-made therapies for patients with cancer. Consequently, a proteome wide analysis, in addition to genomic studies, is an absolute requirement for a complete functional understanding of tumor biology. Ultra-sensitive, high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) currently holds an important role in fulfilling the demands of biomarker discovery. In this review, we describe the applicability of FTICR MS for breast cancer proteomics, particularly for the analysis of complex protein mixtures obtained from a limited number of cells typically available from clinical specimens.
In this book over 250 alloys are organized by AISI number into 10 major sections: Irons, Carbon Steels, Alloy Steels, Low Alloy Constructional Steels, Ultra High Strength Steels, Tool Steels, Maraging Steels, Wrought Stainless Steels, Heat Resistnat Casting Alloys, and Iron Based Rought Superalloys. Each alloy record lists the designation, specifications, UNS number, composition, product forms and a comment on the high-temperature properties and applications. Referenced data is then given for physical properties such as density, specific heat, thermal conductivity, thermal expansion, electrical conductivity, Poisson's ratio, moduli of elasticity and rigidity, etc. Mechanical properties follow, and include tensile properties, shearing and bearing properties, impact properties, creep, stress rupture and stress relaxation and fatigue properties. The last part of the alloy record gives other effects of temperature, such as hot hardness, corrosion, and growth.
A qualitative method, involving supported liquid?liquid extraction (SLE) and ultra high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS?MS), was developed for the rapid tentative identification of various drugs of abuse in urine. In this study, 28 drugs and metabolites were covered by the screening procedure. Before analysis, urine samples were extracted by SLE and good extraction recoveries were obtained for most investigated compounds. The UHPLC strategy was then selected for the rapid separation of amphetamines, cocaine, opiates and related compounds in urine. Using columns packed with sub-2??m particles, analysis time was reduced down to 2?min, while maintaining acceptable performance. Finally, the detection was by tandem MS operating in the single reaction...
In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...
Using ultra-high-frequency data extracted from the order flows of 23 stocks traded on the Shenzhen Stock Exchange, we study the empirical regularities of order placement in the opening call auction, cool period and continuous auction. The distributions of relative logarithmic prices against reference prices in the three time periods are qualitatively the same with quantitative discrepancies. The order placement behavior is asymmetric between buyers and sellers and between the inside-the-book orders and outside-the-book orders. In addition, the conditional distributions of relative prices in the continuous auction are independent of the bid-ask spread and volatility. These findings are crucial to build an empirical behavioral microscopic model based on order flows for Chinese stocks.
Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.
Objectives1. We will use reduction of lysosomal stability as an indicator of cell injury induced by C-60 fullerenes and carbon nanotubes in the liver analogue or digestive gland (hepatopancreas) of marine mussels. Molluscan hepatopancreatic digestive cells are key to normal function and are a sensitive key interface with the environment. Reduction of lysosomal stability is mechanistically linked with impaired health of the whole animal. 2. We will also test the hepatopancreatic digestive cells for evide [continued...]DescriptionNanotechnology is a major innovative scientific and economic growth area, which may present a variety of hazards for environmental and human health. The surface properties and very small size of nanoparticles and nanotubes provides surfaces that may bind and transport toxic chemical pollutants, as well as possibly being toxic in their own right by generating reactive oxygen species (ROS). There is a wealth of evidence for the harmful effects of nanoscale ...
We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area is given. The experience on the commissioning of the cooler ...
Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).
In the present study, human neonatal fibroblasts were isolated from a two-month-old human male. The purpose of the present investigation was the analysis of the morphology (light and transmission electron microscopy), karyotype and growth characteristics of the human neonatal fibroblast cell culture B-HNF-1. Moreover, STR typing and mitochondrial DNA amplification and sequencing was also performed. Analysis of chromosomes count showed that B-HNF-1 cell culture is diploid and has normal male karyotype 46, XY, which was stable during cultivation. The transmission electron microscopy demonstrated the ultra-structure of the B-HNF-1 cells; they have typical morphological features of proteosynthesis-active cells. Large number of fibroblasts bearing different shapes and surface characteristics ad...
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents will define and ...
The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...
Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron distribution. This leads to a ...
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and ...
The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined modality therapy ...
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and ...
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
The development of new steels is always a challenge for the manufacturer of filler metals. In many cases it is obvious that some properties of the base metal cannot be fulfilled with matching filler metals. In some cases, dissimilar filler metals can solve the problem in some cases, there is no chance to meet the requirements of the base metal (for example yield strengths of new ultra high strength steels). This paper deals with different kinds of new steels and the requirements for the weld metal with examples from motor car industry (Mangan Austenite), crane (Ultra high strength steels), earthmoving machinery (Wear-resistant steels) and offshore (Supermartensitic steels). Specific problems will be discussed and best solutions will be highlighted. These examples make clear that the success of new kinds of steels in the market depends on solving the joining problems of these steels. (Abstract Copyright [2007], Wiley Periodicals, Inc.) [German] ...
A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were acquired. (2) Short-term mechanical properties of Mod.9Cr-1Mo steel were evaluated based on the results of ...
Research highlights: {yields} The use of resonant photoemission in its 'core-hole clock' expression for the study of the dynamical charge transfer across hybrid organic-inorganic interfaces and for the intermolecular charge transfer in the bulk of organic thin films is reviewed. {yields} The electronic coupling to the substrate and the efficiency of charge transport across hybrid interfaces is different for individual electronic subsystems of the molecular adsorbate. {yields} The intermolecular charge transfer in the bulk of discotic liquid crystals occurs on the order of a few femtoseconds and is faster than expected from the macroscopic charge transport characteristics of the material. -- Abstract: The focus of this brief review is the use of resonant photoemission in its 'core-hole clock' expression for the study of two important problems relevant for the field of organic electronics: the dynamical charge transfer across hybrid organic-inorganic ...
The high-strength and ultra high-strength steels developed and produced by Thyssen Krupp Stahl make a major contribution to automotive lightweighting. Proven and newly-developed coatings are used to meet increasingly important corrosion protection requirements. Design for materials, optimized forming and joining processes and the use of modern simulation techniques help to exploit the potential of the new steels. Future development work will focus on reducing the density of steels without compromising their well-known advantages - in particular their strength. The use of high-strength and ultra high-strength steels in the automotive industry is on the increase. Steel will remain the material of choice for auto manufacture, above all due to its potential for cost-efficient lightweight construction and its full recyclability. (orig.) [German] Einen wesentlichen Beitrag zum Leichtbau im Automobil leisten die von Thyssen Krupp Stahl entwickelten ...
A simple and rapid laser fluorometric determination of trace and ultra trace level of uranium in a wide variety of low uranium content materials like soil, basic and ultra basic rocks, plant ash, coal fly ash and red mud samples is described. Interference studies of some common major, minor and trace elements likely to be present in different geological materials on uranium fluorescence are studied using different fluorescence enhancing reagents like sodium pyrophosphate, orthophosphoric acid, penta sodium tri-polyphosphate and sodium hexametaphosphate. The accurate determination of very low uranium content samples which are rich in iron, manganese and calcium, is possible only after the selective separation of uranium. Conditions suitable for the quantitative single step extraction of 25 ng to 20 #mu#g uranium with tri-n-octylphosphine oxide and single step quantitative stripping with dilute neutral sodium pyrophosphate, which also acts as ...
The steroidogenic factor 1 (SF-1, also known as NR5A1) is a transcription factor belonging to the nuclear receptor superfamily. Whereas most of the members of this family have been extensively characterized, the therapeutic potential and pharmacology of SF-1 still remains elusive. Described here is the identification and characterization of selective inhibitory chemical probes of SF-1 by a rational ultra-high-throughput screening (uHTS) strategy. A set of 64,908 compounds from the National Institute of Health's Molecular Libraries Small Molecule Repository was screened in a transactivation cell-based assay employing a chimeric SF-1 construct. Two analogous isoquinolinones, ethyl 2-[2-[2-(2,3-dihydro-1,4-benzodioxin-7-ylamino)-2-oxoethyl]-1-oxoisoquinolin-5-yl]oxypropanoate (SID7969543) and ethyl 2-[2-[2-(1,3-benzodioxol-5-ylmethylamino)-2-oxoethyl]-1-oxoisoquinolin-5-yl]oxypropanoate and (SID7970631), were identified as potent submicromolar inhibitors, yielding ...
A comprehensive understanding of dopant activation mechanisms in crystalline Si is required in order to form shallow junctions. In this paper, we will review several experimental assessments on boron clustering and novel methods to form shallow junctions. Boron marker-layer structures have been used to investigate the fundamental aspects of formation and ripening boron-interstitial clusters (BICs) and their influence on the associated transient enhanced diffusion (TED). The samples were damaged by Si implants at different doses in the sub-amorphizing range and annealed at high temperatures. We found that BICs act as a sink for interstitials at supersaturations values S(t)>10{sup 4}. This implies that silicon self-interstitial defects are the primary source of interstitials driving TED, and that BICs act as a secondary 'buffer' for the interstitial supersaturation. These clusters are less sensitive to the ripening process than pure interstitial clusters do, so ...
Ultra-low pure Pt-based electrodes (0.04-0.12 mg_P_t/cm"2) were prepared by dual ion-beam assisted deposition (dual IBAD) method on the surface of a non-catalyzed gas diffusion layer (GDL) substrate. Film thicknesses ranged between 250 and 750 A, these are compared with a control, a conventional Pt/C (1.0 mg_P_t_(_M_E_A_)/cm"2, E-TEK). The IBAD electrode constituted a significantly different morphology, where low density Pt deposits (largely amorphous) were formed with varying depths of penetration into the gas diffusion layer, exhibiting a gradual change towards increasing crystalline character (from 250 to 750 A). Mass specific power density of 0.297 g_P_t/kW is reported with 250 A IBAD deposit (0.04 mg_P_t/cm"2 for a total MEA loading of 0.08 mg_P_t/cm"2) at 0.65 V. This is contrasted with the commercial MEA with a loading of 1 mg_P_t_(_M_E_A_)/cm"2 where mass specific power density obtained was 1.18 g_P_t/kW (at 0.65 V), a value typical of current state of the ...
Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at 1.0 T is probably responsible for the higher intensity at 1.0 T. When MRI is performed after TAE with Lipiodol, the signal ...
Ultra low loading noble metal (0.04-0.12 mg_P_t/cm"2) based electrodes were obtained by direct metallization of non-catalyzed gas diffusion layers via dual ion beam assisted deposition (IBAD) method. Fuel cell performance results reported earlier indicate significant improvements in terms of mass specific power density of 0.297 g_P_t/kW with 250 A thick IBAD deposit (0.04 mg_P_t/cm"2 for a total MEA loading of 0.08 mg_P_t/cm"2) at 0.65 V in contrast to the state of the art power density of 1.18 g_P_t/kW using 1 mg_P_t_(_M_E_A_)/cm"2 at 0.65 V. In this article we report the peroxide radical initiated attack of the membrane electrode assembly utilizing IBAD electrodes in comparison to commercially available E-TEK (now BASF Fuel Cell GmbH) electrodes and find the pathway of membrane degradation as well. A novel segmented fuel cell is used for this purpose to relate membrane degradation to peroxide generation at the electrode/electrolyte interface by means of ...
The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The focus of this work is ...
The objective of this 3.5 year project is to develop a commercially competitive vehicle powered by ethanol (or ethanol blend) that can meet California`s ultra-low emission vehicle (ULEV) standards and equivalent corporate average fuel economy (CAFE) energy efficiency for a light-duty passenger car application. The definition of commercially competitive is independent of fuel cost, but does include technical requirements for competitive power, performance, refueling times, vehicle range, driveability, fuel handling safety, and overall emissions performance. This report summarizes a system design study completed after six months of effort on this project. The design study resulted in recommendations for ethanol-fuel blends that shall be tested for engine low-temperature cold-start performance and other criteria. The study also describes three changes to the engine, and two other changes to the vehicle to improve low-temperature starting, efficiency, and emissions. ...
To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the ...
Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main ...
In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, ...
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
A brief overview if provided of selected reports presented at the International Symposium on Molecular Mechanisms of Radiation- and Chemical Carcinogen-Induced Cell Transformation held at Mackinac Island, Michigan on September 19-23, 1993.
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
PurposeWe conducted a comparative study of Clinical Target Volume (CTV) definition of pelvic lymph nodes by multiple GU radiation oncologists looking at the levels...Full Text Available
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
We show that, in addition to radiation travelling at the speed of light, QED theory predicts a second type of radiation with an infinite velocity. We also show that charge, as it appears in the Dirac equation, may have a triune nature.
Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study
To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
BackgroundMicrovascular injury plays a key role in normal tissue radiation responses. Statins, in addition to their lipid-lowering effects, have vasculoprotective...Full Text Available
This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical ...
The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where ...
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
The radiation method has been employed for the modification of the surface of vascular prostheses by means of acrylamide. As a result of the treatment, the tightness of the prosthesis walls was improved as well as an increase of surface hydrophilicity. Upon autoclaving, stable binding of polyacrylamide to prostheses is achieved. (author).
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior ...
Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be ...
PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available
Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available
Adaptive radiation is the rapid origination of multiple species from a single ancestor as the result of concurrent adaptation to disparate environments. This fundamental evolutionary process is considered...Full Text Available
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.
Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available
The United Kingdom Atomic Energy Authority mortality study was designed to investigate the relation between exposure to ionising radiation and mortality among the authority's employees. The present...Full Text Available
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the ..beta.. chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the #beta# chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
Electron spin resonance spectroscopy can provide a powerful approach to the study of radiation effects in biological materials. This memorandum gives an overview of current and future research. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
Although skin is usually exposed during human exposures to ionizing radiation, there have been no thorough examinations of the transcriptional response of skin fibroblasts and keratinocytes...Full Text Available
Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available
PurposeA dosimetric comparison between multiple static-field intensity-modulated radiation therapy (IMRT), multi-arc intensity-modulated arc therapy (IMAT) and single-arc...Full Text Available
A compensatory response, viz. in vivo recovery from radiation damage to mitochondria, occurs in preclimacteric pear fruits (Pyrus communis L.) treated with ionizing...Full Text Available
This guidebook organizes the profusion of rules and regulations surrounding radiation protection into a single-volume reference. Employee and public protection, accident prevention, and emergency preparedness are included in this comprehensive coverage. Whenever possible, information is presented in convenient checklists, tables, or outlines that enable you to locate information quickly.
The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...
In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available
The mission includes a reflected solar instrument retrieving at-sensor .... incoming solar radiation. This direct aerosol radiative forcing (DARF) ... examining the behavior of geosynchronous rocket bodies and non-stabilized payloads as ...
The chapter presents the nuclear energy development in 20th century and the most important radiation accidents happened from the point of view of technological risk and high impact consequences: Three Mile Island and Chernobyl.
... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...
It may result in acute radiation syndrome after body is exposed to ionizing radiation. The one of long-term effects of irradiation injury is leukemia. The bone marrow cells (BMC) transplantation including stem cells is the only effective therapy for acute radiation syndrome patients. Recently, with the advancement of stem cell research that the stem cells have multipotential and can convert each other, it may supply the new stem source for the irradiation injury patients. At the same time with the further research of radioprotective reagents, the hematopoietic stem cells proliferation after irradiation injury is promoted
Transformation of row material to the consumption goods proceeds by the succession of various technologies using energy and chemicals. Relative contribution of both factors is broadly varied. The chemical reagents are not per se consumption goods and their production is auxiliary. Maximal usage of chemicals is observed in conventional technologies. On the contrary radiation technology does not need chemicals. Therefore usage of radiation technology leads to diminution of chemical processing and hence to the attenuation of the technological press on the environment. As examples the radiation technological methods in conversion of coal and biomass are considered. (author).
The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)
... Animal & Veterinary Cosmetics Radiation-Emitting Products Tobacco Products Drugs Home > Drugs > Resources for You > Information for Consumers (Drugs) Section ...
A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.
In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.
The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.
Death as a criterion (age distribution of occupational death; mean loss of life years due to radiation deaths); accidents at work (incidence of accidents of certain degrees of severity); total loss of working days due to accidents; occupational diseases; somatic and genetic radiation effects; radiation effects during pregnancy (incidence of pregnancies, ristes before implantation, hazards to the embryo, hazards to the foetus, total additional risk due to radiation exposure during pregnancy); age and sex dependence of risk figures; attempted formulation of an index of harm. (HP/orig.).
This book presents the basic ideas of the physics of non-gravitational perturbations and the mathematics required to compute their orbital effects. It conveys the relevance of the different problems that must be solved to achieve a given level of accuracy in orbit determination and in recovery of geophysically significant parameters. Selected Contents are: Orders of Magnitude of the Perturbing Forces, Tides and Apparent Forces, Tools from Celestial Mechanics, Solar Radiation Pressure-Direct Effects: Satellite-Solar Radiation Interaction, Long-Term Effects on Semi-Major Axis, Radiation Pressure-Indirect Effects: Earth-Reflected Radiation Pressure, Anisotropic Thermal Emission, Drag: Orbital Perturbations by a Drag-Like Force, and Charged Particle Drag.
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
Abstract Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from th...
... significant change of spontaneous radiation intensity. It is very sensitive technique allowing the observation of small changes of light absorption. ...
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
Experimental results on study of helium concentration influence on degree of molybdenum radiation hardening for various method of cyclotron doping differing in degree and damage character are presented. It is established that accumulation of helium atoms in molybdenum for simultaneous formation of radiation defects caused by low energetic primary-knocked atoms leads to higher degree of hardening than for high energetic ion irradiation. It is shown that with increase of helium atom concentration the degree of radiation hardening for the same level of damage increases. 4 refs.; 3 figs. (author).
The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.
Various particle-photon or beam-wave interactions are discussed. To be of use as intense radiation sources, it is necessary that these interactions produce coherent radiation. The free electron laser (FEL), developed on the basis of undulator radiation, is the result of many years of interaction between physics and technology. It has many features, such as continuous tunability over a wide wavelength range, excellent optical quality, high power and short pulse capability, and thus has many potential applications. FEL development in China and abroad are mentioned and the Beijing FEL presented to illustrate the physics and technology involved in an FEL project.
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
We consider the radiation of particles (electrons and positrons) undergoing planar channeling in a single crystal of small thickness L. We show that for Lapprox...pi..b/theta/sub L/, where b is the lattice constant and theta/sub L/ is the Lindhard angle, in addition to the principal maxima of spontaneous radiation of channeled particles in the spectrum there are additional interference maxima, and the positions of all maxima of the radiation intensity depend on L. We discuss the dependence of the intensity of radiation at various frequencies on the crystal thickness.
The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)
Treatment of food with low doses of gamma radiation has been recognized to have two main advantages. These consist of: (1) improvement of food safety by elimination of pathogens and (2) reduction of microbial spoilage and extension of shelf life of perishable items by reducing the number of viable spoilage organisms. Studies during the last few decades have conclusively proved the beneficial effects of radiation with respect to fishery products. The three potential areas of application to fish products include: (i) radurization for shelf life extension (ii) radicidation to eliminate food borne pathogens in the products and (iii) radiation treatment to dried products to control insects.
Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.
New non-collinear schemes are suggested for transverse velocity modulation of electron beams and for the generation of coherent spontaneous radiation by these transversely modulated beams. It is shown that due to the non-collinearity some orders of magnitude enhancement can be achieved for the coherent spontaneous radiation (CSR) power at both the fundamental and harmonic frequencies.
One requirement of a thermophotovoltaic (TPV) radiator is to efficiently emit photons at high temperatures to TPV cells for conversion to electric power. Because many candidate radiator materials with adequate structural properties display low emissivity, coatings or other surface modifications are required for enhancement of emissivity. Six plasma sprayed coatings and one textured surface demonstrated adequate thermal stability and emittance values of 0.8 or greater. Promising attributes of modified surfaces are identified.
The application of photopolymerisation (UV) and electron beams (EB) technologies in radiation rapid cure (PRC) processing is discussed. The chemistry associated with such reactions and the mechanisms of the processes are treated. The occurrence of concurrent grafting to substrate with radiation curing of films is shown to be an advantage in enhancing the properties of certain finished products. The parameters influencing the optimum grafting yield in such PRC processes are discussed. In many applications, the chemistry of such processes combined with the machine, specially for EB is shown. (author).
The effect on an oscillator moving in a medium produced by that part of the radiative force which does not perform work but creates and angular moment is considered. It is shown that the radiative torque turns the dipole toward the axis along which it is moving. Near the axis of motion the dipole executes small oscilltions. The frequency of the oscillations is determined. This effect leads to spontaneous alignment of the dipole moments on moving through the medium. The feasibility of observing the effect experimentally is discussed.
In this work, the principal continuum radiative emission processes, which occur during the penetration of ions in solids or gases, are resumed. The characteristics of the following processes are discussed: secondary electron bremsstrahlung (SEB), atomic bremsstrahlung (AB), and internuclear bremsstrahlung (INB). Recent advances of the ion channeling effects in crystal solids on the spontaneous radiative spectra are exposed. (A.C.A.S.).
A solar unit is described which contains a cavity radiation receiver, parabolic-cylindrical concentrator, and reflector arranged between the radiation receiver and the concentrator symmetrically in relation to the optical plane of the latter. In order to expand the range of use, it contains a pair of flat mirrors with 2 working surfaces installed at an angle and symmetrically to the optical plane of the parabolic cylindrical concentrator between them and the reflector, while the latter is made in the form of 2 flat mirrors installed at an angle on the cavity radiation receiver.
Thermal absorption with its combined thermal and mechanical loads in a solar receiver does depend significantly on the distribution of incident solar radiation. For a cavity receiver with paraboloid collectar a method is derived which enables the calculation of solar radiation distribution on the areas inside the receiver. The theoretical bases are presented first, and a subsequent example shows the influence of the most important geometric parameters on the distribution of solar radiation.
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
The influence of additionally injected short-wavelength photobleaching light on the radiation hardness of Ge-doped graded index fibers working at 1,300 nm wavelength is investigated. Predictions are complicated by the fact that more efficient shortwave bleaching light experiences higher radiation-induced loss. Promising results are found for low fiber temperatures (approx-lt -50 C) and bleaching light of about 835 nm wavelength.
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
Only a small number of radiation accidents in the United States have been severe enough to result in multi-organ failure (MOF). Medical details of selected medical misadministration and criticality cases are reviewed, with an emphasis on pathophysiology. The four criticality cases are particularly relevant for analysis of MOF, since medical treatment was supportive and did not appreciably alter the clinical evolution of radiation injury. PMID:15975871
The document, based on European guidelines, was jointly developed by radiation oncologists, radiation physicists and radiation technologists. It contains the aims of the guidelines, professional profiles, roles and responsibilities, personnel and equipment requirements, procedures.
The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.
Effect of single and chronic irradiation on factors of hamsters natural immunity such as complement, lysozyme and antibodies in norm and in the cestode invasion has been investigated. Significant phase changes in the complement activity level, lysozyme content and specific antibodies tite have been shown to occur in hamster blood under the influence of ionizing radiation. Cestode invasion in irradiated host organism increases the negative effect of ionizing radiation on the hamster immyne system.
This review briefly describes current efforts to develop superradiant sources of coherent radiation for the sub-nanometer range of wavelenghs, using nuclear rather than the atomic or molecular transitions that are stimulated in existing lasers. First the radiative (including Raman) interactions of nuclei with those of atoms and molecules are compared; then the present status of research on the fundamental problems involved in stimulating nuclear gamma radiation is described. (author). 20 refs.; 2 figs.
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
When an animal is exposed to a sufficient amount of radiation, there will be changes in many organs of the body, and as a result of either the effects in one particular organ or the interaction of effects in several organs, the animal as a whole will show...
A brief tutorial on the health effects of ionising radiation is presented. The distinction between somatic and genetic health effects is explained. The two types of somatic health effects, i.e., acute and chronic effects, are discussed, as well as the concepts of ''deterministic'' and ''stochastic'' (also called ''probabilistic'') health effects. The possibility of cancer caused by DNA damage is discussed. The document ends with the definition of some key radiation terms.
Dissipation of energy of #beta#"--radiation in polyvinylchloride (PVC) was analyzed. Change of PVC properties at irradiation by beta beams with energy 2,32 MeV was characterized using potentials of inter- and intramolecular interactions as well as Born potential. Correlation between some micro- and macroproperties of PVC was detected and ways of their controlled correction were proposed. (authors)
The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.
The article tries to assess the radiation effects as objectively as possible. In conclusion, some steps that should be taken in future are listed, as e.g.: continuous monitoring of the radioactivity levels in air and soil, and recording of data for complete information. Further, investigation and assessment of radiation exposure of children, especially in regions most heavily affected; radioactivity monitoring of the food and milk given to children, and scientific research into the problem by pediatrists, and determination of maximum acceptable radiation doses. (orig./HSCH).
The Guarantee Outline presents the technical demands of design and contents of assessment for radiation hardening in satellite engineering in China. It includes the basis of design in space environment of polar orbit, the contents of design for general radiation hardening, the requirements and assessments of the single-board computer, the requirements of design for circuits (including hardware and software), the choices and assessments for devices, and the primary stipulations for the requirements of design and assessments against the phenomenon of charge and discharge.
The philosophy of work management in radiation protection puts emphasis on the following up and management of overall process from work selection, planning, preparation, implementation till experience feedback, and overall optimization of production and safety management. This paper reports practices and experiences of Daya Bay nuclear power plant in the implementation of the philosophy during operational radiation protection through the practical examples
Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.
This paper describes the research and development activities in three areas of radiation processing, namely: food irradiation, medical product sterilization and wood plastic combination. Plans and efforts exerted to acquire a larger gamma source to augment our present 5,000 curie source are discussed. Cost estimates for a radiation facility are presented on the basis of the market potential of food irradiation and medical product sterilization. Existing local industries that can benefit from the adaptation of irradiation technology in their processing requirements are described.
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
This book examines the nonlinear optical properties of laser materials. The physical radiation effects on laser materials are also considered. Topics considered include: nonlinear optical properties; nonlinear and harmonic generation materials; two-photon absorption; nonlinear refractive index; stimulated Raman scattering; radiation damage; crystals; and glasses.
Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)
Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.
Cell death after irradiation occurs by apoptosis in certain cell populations in tissues. The phenomenon also occurs after high linear energy transfer (LET) irradiation, and the relative biological effectiveness (RBE) is 3 to 4 (with respect to low-LET radiation and apoptosis in intestinal crypts) for neutrons with energies of 14 MeV and up to 600 MeV. It is thought that p53 plays a role in the phenomenon, as radiation-induced apoptosis is not observed in p53-null animals. (orig.).
Self-amplifying spontaneous radiation free-electron lasers, such as the LCLS or the European X-FEL, rely on the incoherent, spontaneous radiation as the seed for the amplifying process. Though this method overcomes the need for an external seed source one drawback is the incoherence of the effective seed signal. The FEL process allows for a natural growth of the coherence because the radiation phase information is spread out within the bunch due to slippage and diffraction of the radiation field. However, at short wavelengths this spreading is not sufficient to achieve complete coherence. In this presentation we report on the results of numerical simulations of the LCLS X-ray FEL. From the obtained radiation field distribution the coherence properties are extracted to help to characterize the FEL as a light source.
The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different ...
Titanium base 'alpha'-alloys (Pt-7M, RK-20 and Ti-5Al-2Zr-1.5V) are considered for their behaviour under neutron irradiation. The role of alloying elements in radiation hardening is discussed depending of neutron fluence and irradiation temperature. For PK-20 alloy three stages of change in mechanical properties are revealed which are following: incubation period and weak hardening, intense radiation hardening, radiation hardening attenuation. Irradiation temperature rise results in an increase of incubation period and threshold neutron fluence. A special attention is paid to hydrogen absorption in #alpha#-titanium alloys under irradiation. It is concluded that titanium base 'alpha'-alloys are serviceable as structural materials in nuclear plants with allowance made for peculiar features of their radiation behaviour. 4 refs.; 7 figs.; 1 tab.
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and ...
The radiation hardening studies started in the mid decade 1960-1970. To survive the different military or space radiative environment, a new engineering science was born, to understand the degradation of electronics components. The different solutions to improve the electronic behavior in such environments have been named 'radiation hardening' of the technologies. Improvement of existing technologies, and qualification methods have been widely studied. However, on the other hand, specific technologies were developed: the Silicon On Insulator technologies for CMOS or Bipolar. The HSOI3HD technology offers today the highest hardening level for the integration density of hundreds of thousand transistors on the same silicon. Full complex systems could be produced on a single die with a technological radiation hardening and no more system hardening.
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified in German ...
Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.
A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of ...