WorldWideScience
1

Ultra High Strength Beta Titanium Alloy for Fasteners.  

Science.gov (United States)

... Accession Number : ADD151811. Title : Ultra High Strength Beta Titanium Alloy for Fasteners. Descriptive Note : Journal article,. ...

8

A comparative study on ultra-shallow junction formation using co-implantation with fluorine or carbon in pre-amorphized silicon  

Energy Technology Data Exchange (ETDEWEB)

The main driver in ultra-shallow formation for the 65 nm technology node and beyond is to find solutions that both reduce boron transient enhanced diffusion and can be integrated in the CMOS process flow. To this end, many studies have recently focused on using co-doping techniques with fluorine and most recently with carbon. In most cases, one or both of these is co-implanted with a dopant specie in pre-amorphized silicon. In this work, we show a comparative study of fluorine or carbon co-implanted with low-energy boron to form source and drain extension junctions for PMOS devices. We will show that by a systematic optimization of germanium, boron, fluorine or carbon energies and doses, spike annealing technology can be extended to the 65 nm node. These results will be used to discuss how the different formed junctions offer potential solutions for either low-power or high-performance PMOS device fabrication.

2005-12-05

9

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

10

Study of silicon damage caused by ultra-low energy boron implantation  

International Nuclear Information System (INIS)

Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as ...

11

Radiations emitted in the decay of /sup 165/Er: A promising medical radionuclide  

Science.gov (United States)

The 10.3-h /sup 165/Er, decaying by electron capture to stable /sup 165/Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in /sup 165/Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of /sup 169/Er and /sup 171/Er radioactive impurities in the reactor-produced /sup 165/Er sample are experimentally determined. Whole-body dose estimates for /sup 165/Er are given. These compare favorably with /sup 99/Tc dose.

1977-05-01

12

Radiations emitted in the decay of "1"6"5Er: A promising medical radionuclide  

International Nuclear Information System (INIS)

The 10.3-h "1"6"5Er, decaying by electron capture to stable "1"6"5Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in "1"6"5Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of "1"6"9Er and "1"7"1Er radioactive impurities in the reactor-produced "1"6"5Er sample are experimentally determined. Whole-body dose estimates for "1"6"5Er are given. These compare favorably with "9"9Tc dose.

13

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO_2 films  

International Nuclear Information System (INIS)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to obtain very shallow junctions. On the ...

14

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO[sub 2] films  

Energy Technology Data Exchange (ETDEWEB)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to obtain very shallow junctions. On the ...

1993-07-16

15

Issues on boron electrical activation in silicon: Experiments on boron clusters and shallow junctions formation  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive understanding of dopant activation mechanisms in crystalline Si is required in order to form shallow junctions. In this paper, we will review several experimental assessments on boron clustering and novel methods to form shallow junctions. Boron marker-layer structures have been used to investigate the fundamental aspects of formation and ripening boron-interstitial clusters (BICs) and their influence on the associated transient enhanced diffusion (TED). The samples were damaged by Si implants at different doses in the sub-amorphizing range and annealed at high temperatures. We found that BICs act as a sink for interstitials at supersaturations values S(t)>10{sup 4}. This implies that silicon self-interstitial defects are the primary source of interstitials driving TED, and that BICs act as a secondary 'buffer' for the interstitial supersaturation. These clusters are less sensitive to the ripening ...

2002-01-01

16

PV Conversion Technologies, Session: OPV, Sensitized, Seed (Presentation)  

Energy Technology Data Exchange (ETDEWEB)

The NREL Sensitized Solar Cell (SSC) Core Program supports the Solar America Initiative by: (1) targeting new devices and processes for commercialization by 2015 that are less expensive, more efficient, highly reliable, and environmentally benign; (2) collaborating with DOE OS/BES to conduct basic research targeting breakthroughs in key areas, such as ultra-high efficiency and/or ultra-low cost materials and devices.

2008-04-01

17

Non-Linear Dose-Response Relationships in Biology, Toxicology and Medicine - An International Conference  

Energy Technology Data Exchange (ETDEWEB)

Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.

2002-05-28

18

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ...

19

Optimization of advanced PMOS junctions using Ge, B and F co-implants  

International Nuclear Information System (INIS)

The main challenges for PMOS ultra shallow junction formation remain the transient enhanced diffusion (TED) and the solid solubility limit of boron in silicon. It has been demonstrated that low energy boron implantation and spike annealing are key in meeting the 90nm technology node ITRS requirements. To meet the 65nm technology requirements many studies have used fluorine co-implantation with boron and Si"+ or Ge"+ pre-amorphization (PAI) and spike annealing. Although using BF_2"+ can be attractive for its high throughput, self-amorphization and the presence of fluorine, many studies have shown that the fluorine successfully reduce TED, its energy needs to be well optimized with respect to the boron's, therefore BF_2"+ does not present the right fluorine/boron energy ratio for the optimum junction formation. In this work we optimize the fluorine energy for boron energies down to 200eV. We show the dependence of optimized junction on Ge"+ ...

2005-08-01

20

Mechanism of ageing in irradiated polymers  

Energy Technology Data Exchange (ETDEWEB)

Samples of ultra-high molecular weight polyethylene (UHMWPE) and nylon 66, of grades suitable for use in medical prostheses, were subjected to irradiation using a /sup 60/Co source. The effects of a 10 Mrad dose on percentage crystallinity, tensile behaviour and dynamic mechanical response were established 3 days after irradiation at intervals over a one year period. Crystallinity in UHMWPE was found to increase progressively during this period with consequent changes in mechanical behaviour. It is proposed that the observed ageing process arises from the breakdown of metastable groups in the polymer, which are formed on irradiation, with consequent release of long inter-lamella tie chains. This removes an inhibition to crystal perfection processes, which can occur at room temperature in polyethylene. Infra-red spectroscopic evidence supports the proposal that the metastable species is peroxy or hydroperoxy and that this decomposes on ageing to ...

1988-01-01

21

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

22

Railgun. Challenge to ultra-high speed; Railgun. Chokosoku eno chosen  

Energy Technology Data Exchange (ETDEWEB)

A railgun has an armature driven between two rail-like conductors. In other words, it is a linear drive device system that drives airframes by using the Lorentz`s force. The system is expected as a next-generation high-speed transport means, or as a means to create such ultimate fields as ultra-high pressures, ultra-high temperatures, and ultra-ferromagnetic fields. This paper is a report on investigations on the relevant technological trends as surveyed by the investigation committee at the Institute of Electrical Engineers of Japan using research reports published inside and outside the country. The reported themes cover explanations from the construction to the pulse power supply that forms the core of the technology, problems in switching, recent status of research and development, and to application fields. Compatibility in the high-level electrical and mechanical performances ...

1995-09-12

23

System Design and Applications of the Ultra Small ... - GLTRS - NASA  

Science.gov (United States)

The advanced technologies of Ka-Band systems such as high gain spot .... sometimes used based on link requirements for a specific application. .... received at NASA LeRC from a Ku-band satellite and retransmitted to the USAT at Ka-Band. .... and to the Office of Management and Budget, Paperwork Reduction Project ...

24

Investigating of composition, structure and properties of Si modification under variable dose ions implantation influence  

International Nuclear Information System (INIS)

Interest to thin film of metals' silicides first of all is conditioned intrinsic al them unique physical properties. On their basis of it is possible to produce extremely sophisticated devices of solid-state electronics, production which needs the controlled change of physics, chemical and electrical properties with high-level of accuracy. On the present time most are in detail investigated composition, structure and properties of three-dimensional samples of metals' silicides. In the last years the intensive are led to researches in the direction of creation and study of physical-chemical properties thin (500-1000 Angstroms) and ultrafine (100-120 Angstroms) films silicides. It has information about composition, morphology of surface and emission of properties of thin film of silicides of barium, of cobalt and of palladium, was obtained in conditions of ultra-high vacuum. Low energy ion implantation and further annealing on composition, ...

25

Corrosion resistance of Ultra-Low-Carbon 19% Cr-11% Ni stainless steel for nuclear fuel reprocessing plants in nitric acid  

International Nuclear Information System (INIS)

An Ultra-Low-Carbon 19% Cr-11% Ni Stainless Steels used in nuclear fuel reprocessing plants where highly corrosion resistance in nitric acid is required has been developed. This steel has optimized the chemistry composition to decrease inclusions and deformation-induced martensitic transformation. The formation of deformation-induced martensite has the potential danger of accelerating corrosion in nitric acid. In this paper, effects of cold reduction and martensitic transformation on corrosion resistance of Ultra-Low-Carbon Stainless Steels in nitric acid are discussed. The developed steel showed excellent corrosion resistance during long-term exposure to nitric acid. (author).

26

Ultra shallow P+/N junctions using plasma immersion ion implantation and laser annealing for sub 0.1#mu#m CMOS devices  

International Nuclear Information System (INIS)

Classical beam line ion implantation is limited to low energies and cannot achieve P+/N junctions requested for <45nm ITRS node. RTA (rapid thermal annealing) needs to be improved for dopants activation and damage reductions. Spike annealing process also induces a large diffusion mainly due to TED (transient enhanced diffusion). Compared to conventional beam line ion implantation limited to a minimum energy implantation of 200eV, plasma immersion ion implantation (PIII) is an emerging technique to get ultimate shallow profiles (as-implanted) due to no lower limitation of energy and high dose rate. On the another hand, laser thermal processing (LTP) allows to obtain very shallow junction with no TED, abrupt profile and activated depth control. In this paper, we show the implementation of the BF_3 PIII associated with the LTP. Ions from BF_3"+ plasma have been implanted in 200mm n-type silicon wafers with energies from 100eV to 1keV and ...

2005-08-01

27

Ultra-high pressure water jet: Baseline report  

International Nuclear Information System (INIS)

The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is ...

1997-07-01

28

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT colonography also ...

2003-06-01

29

Ultra-thin {sup 242m}Am fuel elements in nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

There is a growing interest in using {sup 242m}Am as a nuclear fuel. The advantages of {sup 242m}Am as a nuclear fuel derive from the fact that {sup 242m}Am has the highest thermal fission cross section. The thermal capture cross section is relatively low and the number of neutrons per thermal fission is high. These nuclear properties make it possible to obtain nuclear criticality with ultra-thin fuel elements. The possibility of having ultra-thin fuel elements enables the use of these fission products directly, without the necessity of converting their energy to heat, as is done in conventional reactors. There are three options of using such highly energetic and highly ionized fission products. - Using the fission products themselves for ionic propulsion. - Using the fission products in an MHD generator, in order to obtain electricity directly. - Using the fission products to heat ...

2000-12-01

30

Tailor die quenching in hot stamping for producing ultra-high strength steel formed parts having strength distribution  

British Library Electronic Table of Contents (United Kingdom)

Tailor die quenching in the hot stamping of quenchable steel sheets was developed to produce ultra-high strength steel formed parts having strength distribution. Local portions of the heated sheet were quenched by holding grooved tools at the bottom dead centre during the stamping. Non-contact portions were generated in the sheet by grooving the tools, and thus the strength in the contact portions is high owing to the quenching and that in the non-contact portions is low owing to the lack of the quenching. Hat-shaped products having a tensile strength of approximately 1.5GPa only at four corners were formed.

2010-01-01

31

Production and characterization of ultrafine WC powders  

International Nuclear Information System (INIS)

The conventional Calzination-Reduction-Carburization (CRC) process offers the potential to manufacture commercial WC powders with median SEM grain sizes below 0.5 pm (ultra fine grades). Strict process control and a high degree of automation have led to increased powder uniformity and high lot-to-lot reliability. The high potential and flexibility of the CRC process is shown by the development of tailor made WC powders with regard to subsequent alloy manufacturing. R and D powders have successfully been processed in full-scale units exhibiting SEM grain sizes of 0.15 - 0.20 pm. This paper discusses the powder characteristics of various ultra fine WC powder grades, stemming from the conventional CRC process. Analytical characterization include also field-emission SEM, bright field TEM, EDX analysis and XRD-line broadening. (author)

2001-05-01

32

Mechanical properties and structure of low-alloy ultra-high strength steels  

Energy Technology Data Exchange (ETDEWEB)

Mechanical properties of P-LDHA and V-ROL N steels of the Czech production are compared with other ultra-high strength steels produced in the world. The most important results can be summarized into following points: 1. Optimally heat treated P-LDHA steel exhibits substantially better strength characteristics then the V-ROL N steel. 2. Optimal tempering temperature of the P-LDHA steel is 300 C. 3. Basic mechanical properties of P-LDHA steel belong to the top of the UHS steels ranking and are well comparable with those of American 300 M steel. 4. In the low-cycle fatigue region, the P-LDHA steel exhibits slightly better fatigue resistance then the 300 M steel. On the other hand, the high-cycle fatigue resistance of 300 M steel is slightly better then that of the P-LDHA steel. (orig.)

2000-07-01

33

Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems  

Energy Technology Data Exchange (ETDEWEB)

We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.

2006-03-06

34

Defect engineering via ion implantation to control B diffusion in Si  

International Nuclear Information System (INIS)

The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the ...

2009-03-15

35

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...

2001-01-01

36

Steel microstructure engineering for large diameter tubes; Engenharia de microestrutura de acos para tubos de grande diametro  

Energy Technology Data Exchange (ETDEWEB)

High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)

2008-05-15

37

New designs for Ultra High High-Power Single Transverse Mode Cw fibre lasers  

International Nuclear Information System (INIS)

Overcoming the limiting constraints of stimulated Raman scattering (SRS) and stimulated Brilluoin scattering (SBS) poses serious fibre design challenges for increasing the output power of optical amplifiers and lasers. New fibre amplifier designs are proposed to break out of these limitations to reach several kWs CW powers. (Author)

2009-04-01

38

Separation of rubidium from irradiated aluminum-encapsulated uranium  

International Nuclear Information System (INIS)

A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.

1993-05-01

39

Separation of rubidium from irradiated aluminum-encapsulated uranium  

Energy Technology Data Exchange (ETDEWEB)

A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.

1982-01-01

40

Hydrogen transport and embrittlement in 300 M and AerMet100 ultra high strength steels  

Energy Technology Data Exchange (ETDEWEB)

This paper describes how hydrogen transport affects the severity of hydrogen embrittlement in 300 M and AerMet100 ultra high strength steels. Slow strain rate tests were carried out on specimens coated with electrodeposited cadmium and aluminium-based SermeTel 1140/962. Hydrogen diffusivities were measured using two-cell permeation and galvanostatic charging methods and values of 8.0 x 10{sup -8} and 1.0 x 10{sup -9} cm{sup 2} s{sup -1} were obtained for 300 M and AerMet100, respectively. A two-dimensional diffusion model was used to predict the hydrogen distributions in the SSR specimens at the time of failure. The superior embrittlement resistance of AerMet100 was attributed to reverted austenite forming around martensite laths during tempering.

2010-05-15

41

Effects of DC gate and drain bias stresses on the degradation of excimer laser crystallized polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V{sub GS} = V{sub DS}/2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted ...

2005-01-01

42

Effects of DC gate and drain bias stresses on the degradation of excimer laser crystallized polysilicon thin film transistors  

International Nuclear Information System (INIS)

The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V_G_S = V_D_S/2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted in ...

2005-01-01

45

Friction in ultra-thin conjunction of valve seals of pressurised metered dose inhalers  

British Library Electronic Table of Contents (United Kingdom)

In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...

2010-01-01

46

Aerogels from Unaltered Bacterial Cellulose: Application of scCO2 Drying for the Preparation of Shaped, Ultra-Lightweight Cellulosic Aerogels  

British Library Electronic Table of Contents (United Kingdom)

Bacterial cellulose produced by the gram-negative bacterium Gluconacetobacter xylinum was found to be an excellent native starting material for preparing shaped ultra-lightweight cellulose aerogels. The procedure comprises thorough washing and sterilization of the aquogel, quantitative solvent exchange and subsequent drying with supercritical carbon dioxide at 40 degreeC and 100 bar. The average density of the obtained dry cellulose aerogels is only about 8 mg cm-3 which is comparable to the most lightweight silica aerogels and distinctly lower than all values for cellulosic aerogels obtained from plant cellulose so far. SEM, ESEM and nitrogen adsorption experiments at 77 K reveal an open-porous network structure that consists of a comparatively high percentage of large mesopores and small...

2010-01-01

47

High-energy cosmic-ray nuclei from high- and low-luminosity gamma-ray bursts and implications for multi-messenger astronomy  

CERN Document Server

Gamma-ray burst (GRB) is one of the candidates of high-energy cosmic-ray acceleration sites. They may be also ultra-high-energy (above 3 EeV) cosmic-ray (UHECR) sources. In this paper, we discuss possibilities and implications of high-energy cosmic-ray acceleration in GRBs. (1) First, we show that not only protons but also heavier nuclei can be accelerated up to ultra-high energies in both usual high-luminosity (HL) and low-luminosity (LL) GRBs by using the Geant4. LL GRBs may also make a significant contribution to the observed UHECR flux if they form a distinct population, and we investigate cosmic-ray acceleration in LL GRBs in detail. (2) Second, we discuss implications of the GRB-UHECR hypothesis (and Hypernova-UHECR hypothesis) to cosmic-ray astronomy. HL GRBs and LL GRBs will lead to different source number densities as UHECR sources, so that the determination of the number ...

2008-01-01

48

Development of a fine and ultra-fine group cell calculation code SLAROM-UF for fast reactor analyses  

International Nuclear Information System (INIS)

A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous energy Monte Carlo calculations. It was ...

2006-08-01

49

Ultra high vacuum test setup for electron gun  

Energy Technology Data Exchange (ETDEWEB)

Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra ...

2008-05-01

50

Method of defining features on materials with a femtosecond laser  

Energy Technology Data Exchange (ETDEWEB)

The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.

2006-05-23

51

Ultrashallow P{sup +}/N junction formation by plasma ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B{sub 2}H{sub 6} plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B{sub 2}H{sub 6} plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for ...

2000-12-01

52

Ultrashallow P"+/N junction formation by plasma ion implantation  

International Nuclear Information System (INIS)

We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B_2H_6 plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B_2H_6 plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for ...

2000-12-01

53

Oxygen stabilization induced enhancement in superconducting characteristics of high-Tc oxides  

International Nuclear Information System (INIS)

In an attempt to enhance the electrical and mechanical properties of the high temperature superconducting oxides, high T(sub c) composites were prepared composed of the 123 compounds and AgO. The presence of extra oxygen due to the decomposition of AgO at high temperature is found to stabilize the superconducting 123 phase. Ag is found to serve as clean flux for grain growth and precipitates as pinning center. Consequently, almost two orders of magnitude enhancement in critical current densities were also observed in these composites. In addition, these composites also show much improvement in workability and shape formation. On the other hand, proper oxygen treatment of Y5Ba6Cu11Oy was found to possibly stabilize superconducting phase with T(sub c) near 250 K. I-V, ac susceptibility, and electrical resistivity measurements indicate the existence of this ultra high T(sub c) phase in ...

1991-01-01

54

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated ...

2003-07-01

55

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

56

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

57

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...

2001-04-01

58

Technologies for high speed rolling and control of gauge in cold tandem mill for ultra-thin gauge strip; Gokuusu reikan atsuenki ni okeru kosoku atsuen gijutsu oyobi itaatsu seigyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

This paper describes high speed rolling and gauge control in cold tandem mill for ultra-thin gauge strip at the Chiba Works of Kawasaki Steel Corporation. To improve the plate-out property of rolling oil, cationic polymeric coagulant was prepared. Rolling oil with cohesion independent of inorganic inclusions or phosphatide was developed, to improve the lubrication for cold rolling, remarkably. In addition, a low-cost Ti-enhanced work roll having high wear resistance and excellent grindability was developed. Rolling can be conducted at the optimal rolling roughness and operation can be performed at the highest rolling speed independent of the rolling treatment amount. Rolling speed at 2800 m/min was confirmed by developing the rolling oil with excellent lubrication and the work roll having high wear resistance. For the improvement of strip thickness accuracy at the steady state rolling, use of the backup ...

1996-09-01

59

Effect of V and W addition on the high temperature strength properties of 12%Cr-15%Mn austenitic steels. 12%Cr-15%Mn austenite ko no ondo kyodo ni oyobosu V to W tenka no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Experimental discussions were given on effect of V and W addition on the high temperature strength properties of 12% Cr-15% Mn austenite steels. The test samples were added with W at 0% to 3.5% and V at 0% to 0.5% in addition to C and N, and were given aging treatment or solution treatment. This paper describes the following matters on the results of high-temperature strength measurements and structural observation: A remarkable trend was observed that M23 Cb type carbides precipitate in the aging treatment, wherein aging hardening appears prominently which is attributable to ultra-fine deposits of vanadium nitride (VN) in the V-added material; the V addition is very effective in increasing the high-temperature tensile strength and creep fracture strength as compared with single W addition, wherein the said carbides that accelerate the precipitation as a result of the V addition make a large ...

1992-11-01

60

Boron-enhanced-diffusion of boron: The limiting factor for ultra-shallow junctions  

Energy Technology Data Exchange (ETDEWEB)

Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).

1997-12-01

61

Studies of ultra-low energy electron-molecule collisions using very-high-n Rydberg atoms  

International Nuclear Information System (INIS)

Potassium atoms in selected high-lying np Rydberg states (80 #<=# n #<=# 400) are being used as a tool to examine electron-polar molecule collisions at ultra-low energies (#approx#80 #mu#eV - 1 meV). This energy regime has not been investigated previously and is of interest because the corresponding electron de Broglie wavelength is large, #approx#1300 - 330 Angstrom, and because the collision time is comparable to the period of molecular rotation. A variety of target molecules has been studied, including simple rotors such as HF, and more complex species such as NH_3, CH_3I, CH_2Br_2 and C_6H_5NO_2. These targets encompass a range of dipole moments and rotational behavior, but analysis of the data shows that in each case the cross section #sigma#(#epsilon#) for rotationally-inelastic electron-polar molecule scattering varies approximately as 1/#epsilon# where #epsilon# is the electron energy. Such threshold behavior is not predicted by ...

1993-05-16

62

Analysis of algorithms for ultra high speed relays for the protection of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified version of the well known ...

1984-01-01

63

Ultra-thin lithium micro-batteries. Performances and applications; Microaccumulateurs ultra minces au lithium. Performances et applications  

Energy Technology Data Exchange (ETDEWEB)

This short paper (abstract) describes the characteristics and performances of prototypes of ultra-thin lithium micro-batteries (thickness < 0.2 mm) which can be incorporated into microelectronic circuits. (J.S.)

1996-12-31

64

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations ...

2007-08-01

65

Mammary carcinogenesis in the rat after low-dose irradiation  

International Nuclear Information System (INIS)

Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after ...

1992-07-12

66

Milk residues and performance of lactating dairy cows administered high doses of monensin  

UK PubMed Central (United Kingdom)

AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available

2005-07-01

67

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

68

High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A  

CERN Document Server

Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which ...

2009-01-01

69

Electrical properties of ultra-thin oxynitrided layer using N{sub 2}O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

Energy Technology Data Exchange (ETDEWEB)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics ...

2007-06-04

70

Electrical properties of ultra-thin oxynitrided layer using N_2O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

International Nuclear Information System (INIS)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics ...

2007-06-04

71

Dosimetric Implications of Atmospheric Dispersal of Tritium Near a Heavy-water Research Reactor Facility  

Energy Technology Data Exchange (ETDEWEB)

An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. Tritiated water ...

2001-07-01

72

Simulation on energy deposition process due to anisotropic fast electron transport in high density plasma  

International Nuclear Information System (INIS)

Energy deposition process by relativistic fast electrons produced by ultra-intense laser pulses is discussed. The process is calculated with a two dimensional Fokker-Planck simulation code including binary and collective collisions coupled with electromagnetic field. We focused on Velocity Distribution Function (VDF) dependence in the simulation. The results show that the spread angle of the fast electrons distribution affects energy deposition area and deposited energy is concentrated in the vicinity of the propagation axis of the fast electrons. It may be also suggested that self-pinch effect of a fast electron beam causes large deposition energy. (author)

2008-03-01

73

Problems and approach to geological disposal of radioactive waste  

International Nuclear Information System (INIS)

This feature articles described a concept and technical problems of geological disposal of high-level radioactive waste in the civil engineering. It consists of six papers such as the present statues and subjects of geological disposal by KITAYAMA Kazumi, the diastrophism, igneous activity, and upheaval and erosion by YAMAZAKI Haruo, the groundwater flow and evaluation of nuclear transfer by IJIRI Yuji, evaluation of alteration of cement materials in the ultra-long period by HAGA Kazuko, The Mizunami Underground Research Laboratory in course of construction by SAKAMAKI Masanori, and interview of the ninetieth president of JSCE (Japan Society of Civil Engineers), he places his hope on JSCE and civil engineers by KISHI Kiyoshi. (S.Y.)

2006-11-01

74

Multilayer ultra high gradient insulator technology  

Energy Technology Data Exchange (ETDEWEB)

We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.

1998-03-27

75

Improved formability of ultra high strength steels through local heat treatment  

Energy Technology Data Exchange (ETDEWEB)

In this paper it is described how a martensitic steel sheet with tensile strength of 1400 MPa is heat treated locally. The sheet is then formed in the heat treated regions in a way that would be impossible with the untreated material. Mechanical properties and forming limit diagrams of the heat treated material are determined and the forming operations are simulated, which shows that the method can be used by designers. Although the method has been known for decades, it remains to be industrialised and the work presented here is to be seen as a contribution to this development. (orig.)

2005-07-01

76

Coverage and large scale anisotropies estimation methods for the Pierre Auger Observatory  

Energy Technology Data Exchange (ETDEWEB)

When searching for anisotropies in the arrival directions of Ultra High Energy Cosmic Rays, one must estimate the number of events expected in each direction of the sky in the case of a perfect isotropy. We present in this article a new method, developed for the Auger Observatory, based on a smooth estimate of the zenith angle distribution obtained from the data itself (which is essentially unchanged in the case of the presence of a large scale anisotropy pattern). We also study the sensitivity of several methods to detect large-scale anisotropies in the cosmic ray arrival direction distribution : Rayleigh analysis, dipole fitting and angular power spectrum estimation.

2005-07-01

77

Mesodynamics in the SARS nucleocapsid measured by NMR field cycling  

Energy Technology Data Exchange (ETDEWEB)

Protein motions on all timescales faster than molecular tumbling are encoded in the spectral density. The dissection of complex protein dynamics is typically performed using relaxation rates determined at high and ultra-high field. Here we expand this range of the spectral density to low fields through field cycling using the nucleocapsid protein of the SARS coronavirus as a model system. The field-cycling approach enables site-specific measurements of R{sub 1} at low fields with the sensitivity and resolution of a high-field magnet. These data, together with high-field relaxation and heteronuclear NOE, provide evidence for correlated rigid-body motions of the entire {beta}-hairpin, and corresponding motions of adjacent loops with a time constant of 0.8 ns (mesodynamics). MD simulations substantiate these findings and provide direct verification of the time scale and collective nature of these motions.

2009-09-15

78

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high ...

1976-01-01

79

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL ...

1991-06-01

80

Leading research on supermetal. Part 1. Large-scale materials (iron system); Super metal no sendo kenkyu. 1. Ogata sozai (tetsukei)  

Energy Technology Data Exchange (ETDEWEB)

Supermetal with critical characteristics is under advanced investigation for further improvement of metal materials. Although iron is most frequently used as structural material among various metals, it should be used more carefully and effectively because of resource limitation and global environmental problem. It is essential to draw various excellent properties much more from iron and to improve recyclability. In particular, the best way to meet these requirements is achievement of more fine structure and higher purity. Since the lowest crystalline grain size is now limited to nearly 10{mu}m, metallic structure composed of grains below 1{mu}m is expected by mesoscopic control. Various methods have been studied to achieve ultra-fine crystalline structure, and study of precise heat treatment control and ultra-strength metallurgy is required. Heat treatment in magnetic field and layered structure by mechanical alloying are also promising. ...

1996-03-01

81

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

82

Dose enhancement in bone in electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for ...

1984-05-01

83

Dose enhancement in bone in electron beam therapy  

International Nuclear Information System (INIS)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for ...

84

Howard Hughes Medical Institute dose assessment survey  

Energy Technology Data Exchange (ETDEWEB)

Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs.

1996-12-01

85

High-temperature property data: Ferrous alloys  

Energy Technology Data Exchange (ETDEWEB)

In this book over 250 alloys are organized by AISI number into 10 major sections: Irons, Carbon Steels, Alloy Steels, Low Alloy Constructional Steels, Ultra High Strength Steels, Tool Steels, Maraging Steels, Wrought Stainless Steels, Heat Resistnat Casting Alloys, and Iron Based Rought Superalloys. Each alloy record lists the designation, specifications, UNS number, composition, product forms and a comment on the high-temperature properties and applications. Referenced data is then given for physical properties such as density, specific heat, thermal conductivity, thermal expansion, electrical conductivity, Poisson's ratio, moduli of elasticity and rigidity, etc. Mechanical properties follow, and include tensile properties, shearing and bearing properties, impact properties, creep, stress rupture and stress relaxation and fatigue properties. The last part of the alloy record gives other effects of temperature, ...

1987-01-01

86

Embedded systems for vacuum control at PEFP  

International Nuclear Information System (INIS)

Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.

2005-05-26

87

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)

89

Fostering the commercialization of ultra capacitors  

Energy Technology Data Exchange (ETDEWEB)

This document presents the activity of KiloFarad International (KFI), a trade association for the promotion of the interests of the international ultra-capacitor industry through education and representation. KFI provides a forum for the ultra-capacitor industry to work on non-competitive activities (standards, working groups, test procedures etc..). The rest of the document presents some informations about ultra-capacitors technology and some advanced applications in the automotive and telecommunication industries. (J.S.)

2004-07-01

90

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...

2006-04-01

91

Methylisothiazolinone contact allergy and dose-response relationships  

DEFF Research Database (Denmark)

Methylisothiazolinone (MI) used alone is a new preservative causing a high prevalence of contact allergy. The eliciting threshold of MI is unknown. The combination of MI and phenoxyethanol enhances the antimicrobial efficacy of MI.

2011-01-01

92

High-dose insulin: A consecutive case series in toxin-induced cardiogenic shock  

British Library Electronic Table of Contents (United Kingdom)

Context. Cardiovascular medication overdoses can be difficult to treat. Various treatment modalities are currently recommended. Objective. To describe patient outcomes and adverse events of high-dose insulin therapy in consecutive overdose patients in cardiogenic shock after implementation of a high-dose insulin protocol (1-10 U/kg/h, while avoiding or tapering off vasopressors). Methods. This is an observational consecutive case series of patients identified from a registry. Data were collected by retrospective chart review of patients treated by our toxicology service with this protocol from February 2007 until March 2010. Results. Twelve patients were treated with high-dose insulin. The mean age was 36.5 years (SD 11.7). Seven patients had pre-existing vasopressor therapy, and all were ...

2011-01-01

93

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data ...

2007-09-15

94

The circadian rhythm for the number and sensitivity of radiation-induced apoptosis in the crypts of mouse small intestine  

Energy Technology Data Exchange (ETDEWEB)

Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).

1990-07-01

95

Study of dose variation in various body parts with respect to chest dose in the working environment  

International Nuclear Information System (INIS)

Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)

2011-02-22

96

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped ...

2006-02-07

97

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, found at surfaces of ...

2005-04-01

98

Enhancement of Heat and Mass Transfer in Mechanically Contstrained Ultra Thin Films  

Energy Technology Data Exchange (ETDEWEB)

Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of absorption and desorption systems can be ...

2005-01-01

99

Ultratrace determination in high purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 2; Ultra trace analysis using ion chromatography. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 2; Ionenchromatographische Ultraspurenanalyse  

Energy Technology Data Exchange (ETDEWEB)

The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.

1992-01-31

100

Ultra high strength beta titanium alloy for fasteners  

International Nuclear Information System (INIS)

A new high strength titanium alloy has been developed primarily intended for fastener applications. While Ti-6Al-4V is used extensively as a fastener alloy in the aerospace industry, its shear strength allowable is limited to 655 MPa (95 ksi). For higher shear strength requirements, various steels or nickel-based alloys are used (up to 860 MPa (125 ksi)), but with the attendant density penalty. This new alloy is intended to provide the 860 MPa shear strength at roughly a 40% weight savings. After screening various alloy systems, the optimum chemistry has been selected as follows: Ti-6.0V-6.2Mo-5.7Fe-3Al. In light of its 125 ksi shear strength goal, the alloy has been designated TIMETAL reg-sign 125.

1993-02-21

101

Hot dip galvanised dual phase steels for automotive applications  

Energy Technology Data Exchange (ETDEWEB)

The automotive industry desires to optimize safety and lightweight construction for the production of cars and trucks. The resulting task for steel suppliers is to make steel grades available that can fulfil these requirements. Different projects have shown optimistic outlooks for optimization of safety and reduction of the weight of automobile bodies by using different high strength and ultra high strength steels. In the last group the dual phase steels play the lead. In recent years different steel grades have been developed and optimized for these applications. On one hand developing the mechanical properties as well as joining and forming of dual phase steels is one of the first steps. On the other hand different coated surfaces for various applications of dual phase steels is another step. Starting with characteristic production conditions for cold rolled hot dip galvanised dual phase steels, the mechanical properties ...

2005-07-01

102

High-throughput proteomics of breast carcinoma cells: a focus on FTICR-MS  

Energy Technology Data Exchange (ETDEWEB)

Discovery of better biomarkers for diagnosis, prognosis, and therapy-response prediction is the most critical task of a scientific quest aimed at developing newly designed, tailor-made therapies for patients with cancer. Consequently, a proteome wide analysis, in addition to genomic studies, is an absolute requirement for a complete functional understanding of tumor biology. Ultra-sensitive, high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) currently holds an important role in fulfilling the demands of biomarker discovery. In this review, we describe the applicability of FTICR MS for breast cancer proteomics, particularly for the analysis of complex protein mixtures obtained from a limited number of cells typically available from clinical specimens.

2008-06-05

103

High-Throughput Screening of Drugs of Abuse in Urine by Supported Liquid?Liquid Extraction and UHPLC Coupled to Tandem MS  

British Library Electronic Table of Contents (United Kingdom)

A qualitative method, involving supported liquid?liquid extraction (SLE) and ultra high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS?MS), was developed for the rapid tentative identification of various drugs of abuse in urine. In this study, 28 drugs and metabolites were covered by the screening procedure. Before analysis, urine samples were extracted by SLE and good extraction recoveries were obtained for most investigated compounds. The UHPLC strategy was then selected for the rapid separation of amphetamines, cocaine, opiates and related compounds in urine. Using columns packed with sub-2??m particles, analysis time was reduced down to 2?min, while maintaining acceptable performance. Finally, the detection was by tandem MS operating in the single reaction...

2009-01-01

104

COSY synchrotron and storage ring for medium energy physics  

Energy Technology Data Exchange (ETDEWEB)

At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area is given. The ...

1993-01-01

105

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

106

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the ...

2007-06-05

107

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

108

Optimizing the conditioning regimen for allogeneic stem-cell transplantation in acute myeloid leukemia; dose intensity is still in need  

British Library Electronic Table of Contents (United Kingdom)

Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...

2011-01-01

109

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let ...

2006-07-01

110

High-dose neutron-irradiation effects in fcc metals at 4.6 K  

International Nuclear Information System (INIS)

The rate of residual-resistivity increase and the isochronal recovery have been studied on the fcc metals Al, Ni, Cu, Pd, Ag, Pt, and Au irradiated at 4.6 K with reactor neutrons to a dose of about 10"1"9 (fast neutrons)/cm"2. The rate of resistivity increase is nonlinear as a function of irradiation-induced resistivity; computer analysis shows that the data are best fitted with an erxpression having up to third-order terms in #DELTA#rho. There are deviations from simple damage-rate theory in all cases, but an anomalous negative deviation from a linear law (convex curvature) is observed in Ni, Pd, Pt (and Fe). This behavior is most probably caused by a decrease of the specific Frenkel-defect resistivity due to defect clustering, an effect which should contribute in all metals after fast-neutron irradiation to high doses. Saturation values of resistivity and defect concentration as well as recombination volumes have veen ...

1977-12-01

111

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized ...

2010-10-01

112

High current implantation of negative copper ions into silica glasses  

Energy Technology Data Exchange (ETDEWEB)

High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.

1997-12-01

113

Tertiary-Butanol: A toxicological review  

British Library Electronic Table of Contents (United Kingdom)

Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...

2010-01-01

114

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional ...

1981-01-01

115

Preparation of wood-polymer composites using radiation  

International Nuclear Information System (INIS)

Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there was no improvement in the mechanical ...

1976-11-25

116

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

117

Status and potential of materials development as reflected in steels for the automotive industry; Stand und Potential der Werkstoffentwicklung am Beispiel der Staehle fuer die Automobilindustrie  

Energy Technology Data Exchange (ETDEWEB)

The high-strength and ultra high-strength steels developed and produced by Thyssen Krupp Stahl make a major contribution to automotive lightweighting. Proven and newly-developed coatings are used to meet increasingly important corrosion protection requirements. Design for materials, optimized forming and joining processes and the use of modern simulation techniques help to exploit the potential of the new steels. Future development work will focus on reducing the density of steels without compromising their well-known advantages - in particular their strength. The use of high-strength and ultra high-strength steels in the automotive industry is on the increase. Steel will remain the material of choice for auto manufacture, above all due to its potential for cost-efficient lightweight construction and its full recyclability. (orig.) [German] Einen wesentlichen ...

1999-04-01

118

Use of fuel cells to meet military requirements for mobile power  

International Nuclear Information System (INIS)

'Full text:' The use of fuel cell technology in military applications will depend on safe, high energy density systems being developed. An important part of using this technology is also the development of alternative hydrogen producing fuels with high energy densities and are easy to transport. Fuel cells are now a very large R and D effort for several military applications around the world. The major reason is because of the high power demands needed requires electrical energy sources that far exceed the capabilities of batteries currently being fielded for portable applications. Fuel cells are regarded as highly efficient, tactical energy converters that can be adapted for wide range of power requirements. They are potentially the lowest weight power source when coupled with batteries or capacitors to form hybrid systems. Generally electrical power is needed to support a number of applications from ...

2004-09-25

119

High-performance hybrid pervaporation membranes with superior hydrothermal and acid stability  

Energy Technology Data Exchange (ETDEWEB)

A new organic-inorganic hybrid membrane has been prepared with exceptional performance in dewatering applications. The only precursor used in the sol-gel synthesis of the selective layer was organically linked 1,2-bis(triethoxysilyl)ethane (BTESE). The microporous structure of this layer enables selective molecular sieving of small molecules from larger ones. In the dehydration of n-butanol with 5% of water, the membrane shows a high separation factor of over 4000 and ultra-fast water transport at a rate of more than 20 kg m{sup -2} h{sup -1} at 150C. This can be related to the high adsorption capacity of the material and the sub-micron thickness of the selective layer. The selectivity has now remained constant over almost one and a half years under continuous process testing conditions. Apart from the hydrothermal stability, the membrane exhibits a high tolerance for acid contamination. A slow ...

2009-05-15

120

Untersuchungen zur Anwendung von UHPFRC-Tubbingen bei der zweischaligen Tunnelbauweise  

British Library Electronic Table of Contents (United Kingdom)

Faserbewehrter Beton wird heute zunehmend auch bei Tunnelbauwerken (Tunnelinnenschalen, Tubbinge) eingesetzt. Wesentliche Vorteile sind das hohe Tragvermogen, das daraus entstehende Einsparungspotential an herkommlicher stabformiger Bewehrung (Biegebewehrung, Bugelbewehrung in der Randzone), die Aufnahme von Spaltzugbeanspruchungen durch die Fasern, Rissbreitenbegrenzung, erhohte Dauerhaftigkeit, verbesserter Brandwiderstand (insbesondere bei Verwendung von Kunststofffasern), Optimierung der Arbeitsablaufe etc. Neue Entwicklungen in der Betontechnologie haben in den letzten Jahrzehnten den faserbewehrten ultrahochfesten Beton (engl. UHPFRC - Ultra High Performance Fibre Reinforced Concrete) hervorgebracht. Im Rahmen dieser Arbeit wird der Einsatz des ultrahochfesten, stahlfaserbewehrten Be...

2010-01-01

121

Pulsed laser deposition of titanium-carbonitride thin films  

Energy Technology Data Exchange (ETDEWEB)

The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).

1997-05-15

122

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

123

Optimized pre-amorphization conditions for the formation of highly activated ultra shallow junctions in silicon-on insulator  

International Nuclear Information System (INIS)

Pre-amorphization of ultrashallow implanted boron in Silicon-on-insulator is optimized to produce an abrupt box-like doping profile with negligible electrical deactivation and significantly reduced transient enhanced diffusion. The effect is achieved by positioning the as-implanted amorphous/crystalline interface close to the buried oxide interface, to minimize interstitials whilst leaving a single-crystal seed to support solid-phase epitaxy. Based on a simple physical model of our results, we estimate that the interface between the Si overlayer and the buried oxide is an efficient interstitial sink with a recombination length of the order of 10nm or less under our experimental conditions. (author)

2008-12-01

124

Empirical regularities of order placement in the Chinese stock market  

CERN Document Server

Using ultra-high-frequency data extracted from the order flows of 23 stocks traded on the Shenzhen Stock Exchange, we study the empirical regularities of order placement in the opening call auction, cool period and continuous auction. The distributions of relative logarithmic prices against reference prices in the three time periods are qualitatively the same with quantitative discrepancies. The order placement behavior is asymmetric between buyers and sellers and between the inside-the-book orders and outside-the-book orders. In addition, the conditional distributions of relative prices in the continuous auction are independent of the bid-ask spread and volatility. These findings are crucial to build an empirical behavioral microscopic model based on order flows for Chinese stocks.

2007-01-01

125

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

126

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

127

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made ...

2000-01-01

128

Is uniform target dose possible in IMRT plans in the head and neck?  

International Nuclear Information System (INIS)

Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition ...

2002-04-01

129

Influence of wood extractives in the polymerization of methyl methacrylate by gamma irradiation  

International Nuclear Information System (INIS)

Those materials that can be extracted from pine or oak by ether, ethanol, methyl methacrylate (MMA), or benzene--alcohol all act as inhibitors in the #gamma# polymerization of MMA--wood composites. It was found that preirradiation of either the wood or of the wood--monomer combination reduces or eliminates the inhibitory effect. The most practical industrial solution to this problem is to increase the dose, thereby achieving high molecular polymer in the composite. However, the presence of a maximum in the molecular weight--dose curves means that each wood--monomer pair may have a different optimum dose.

1975-01-01

130

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

131

A dose computation algorithm used in MLC conformal treatment  

International Nuclear Information System (INIS)

A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)

2007-12-01

132

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a ...

2004-12-01

133

Ultra-high temperature strength properties on Mod.9Cr-1Mo steel  

Energy Technology Data Exchange (ETDEWEB)

A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were acquired. (2) Short-term mechanical properties of Mod.9Cr-1Mo steel were evaluated ...

2000-03-01

134

Dose proportionality and the effect of food on vildagliptin, a novel dipeptidyl peptidase IV inhibitor, in healthy volunteers.  

Science.gov (United States)

Vildagliptin is a potent and selective dipeptidyl peptidase IV inhibitor in development for the treatment of type 2 diabetes that improves glycemic control by enhancing alpha- and beta-cell responsiveness to glucose. Two open-label, single-dose, randomized, crossover studies in healthy subjects (ages 18-45 years) investigated the dose proportionality of vildagliptin pharmacokinetics (n = 20) and the effect of food (n = 24) on vildagliptin pharmacokinetics. There was a linear relationship (r(2) = 0.999) between vildagliptin doses of 25, 50, 100, and 200 mg and area under the plasma concentration-time curve from time zero to infinity (AUC(0-infinity)) and maximum plasma concentration (C(max)). Dose proportionality was assessed using a statistical power model [X = alpha x (dose)(beta)]. The 90% confidence intervals of the proportionality coefficient, beta, for AUC(0-infinity) ...

2007-07-26

135

Hybrid electric vehicles and electrochemical storage systems - a technology push-pull couple  

Energy Technology Data Exchange (ETDEWEB)

In the advance of fuel cell electric vehicles (EV), hybrid electric vehicles (HEV) can contribute to reduced emissions and energy consumption of personal cars as a short term solution. Trade-offs reveal better emission control for series hybrid vehicles, while parallel hybrid vehicles with different drive trains may significantly reduce fuel consumption as well. At present, costs and marketing considerations favor parallel hybrid vehicles making use of small, high power batteries. With ultra high power density cells in development, exceeding 1 kW/kg, high power batteries can be provided by adapting a technology closely related to consumer cell production. Energy consumption and emissions may benefit from regenerative braking and smoothing of the internal combustion engine (ICE) response as well, with limited additional battery weight. High power supercapacitors may assist the ...

1999-12-01

136

Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE  

International Nuclear Information System (INIS)

A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.

1990-07-16

137

[Single and 4-week oral toxicity studies of prulifloxacin (NM441) in aged dogs].  

Science.gov (United States)

Single-dose and repeated dose toxicity studies of prulifloxacin, a new antibacterial agent, were conducted in aged beagle dogs. I. A single-dose toxicity study Prulifloxacin was administered orally to aged female dogs at a single dose of 2500 and 5000 mg/kg. No death occurred in any group. Vomiting was observed in one of two animals at 2500 mg/kg and in both animals at 5000 mg/kg 3-4 hr after dosing. At 5000 mg/kg, vomiting was observed in both animals after feeding on the day after dosing. One animal also showed soft stool. Thereafter, no abnormalities were observed in any animal. No test article related changes were noted in food consumption, water consumption, body weight or pathological examination in any group. The results show that the lethal dose of prulifloxacin is judged to be greater than 5000 mg/kg in aged female dogs. II. A ...

1996-06-01

138

Treatment of uteral cancer by the brake irradiation (25 MeV)  

International Nuclear Information System (INIS)

The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.

139

Report of National Cancer Institute symposium: comparison of mechanisms of carcinogenesis by radiation and chemical agents. I. Common molecular mechanisms  

Science.gov (United States)

Some aspects of molecular mechanisms common to radiation and chemical carcinogenesis are discussed, particularly the DNA damage done by these agents. Emphasis is placed on epidemiological considerations and on dose-response models used in risk assessment to extrapolate from experimental data obtained at high doses to the effects from long-term, low-level exposures. 3 references, 6 figures. (ACR)

1984-01-01

140

Comparison of the genetic effects of equimolar doses of ENU and MNU: While the chemicals differ dramatically in their mutagenicity in stem-cell spermatogonia, both elicit very high mutation rates in differentiating spermatogonia  

UK PubMed Central (United Kingdom)

Mutagenic, reproductive, and toxicity effects of two closely related chemicals, ethylnitrosourea (ENU) and methylnitrosourea (MNU), were compared at equimolar and near-equimolar doses in the...Full Text Available

2007-03-01

141

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and ...

142

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron  

International Nuclear Information System (INIS)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak of precipitated dopants produced during ...

143

Weld metal as strong as base metal?; Schweisszusatzwerkstoffe koennen/muessen nicht immer die Anforderungen der Grundwerkstoffe erfuellen  

Energy Technology Data Exchange (ETDEWEB)

The development of new steels is always a challenge for the manufacturer of filler metals. In many cases it is obvious that some properties of the base metal cannot be fulfilled with matching filler metals. In some cases, dissimilar filler metals can solve the problem in some cases, there is no chance to meet the requirements of the base metal (for example yield strengths of new ultra high strength steels). This paper deals with different kinds of new steels and the requirements for the weld metal with examples from motor car industry (Mangan Austenite), crane (Ultra high strength steels), earthmoving machinery (Wear-resistant steels) and offshore (Supermartensitic steels). Specific problems will be discussed and best solutions will be highlighted. These examples make clear that the success of new kinds of steels in the market depends on solving the joining problems of these steels. (Abstract Copyright ...

2007-07-15

144

Potent, selective and cell penetrant inhibitors of SF-1 by functional ultra-high-throughput screening.  

Science.gov (United States)

The steroidogenic factor 1 (SF-1, also known as NR5A1) is a transcription factor belonging to the nuclear receptor superfamily. Whereas most of the members of this family have been extensively characterized, the therapeutic potential and pharmacology of SF-1 still remains elusive. Described here is the identification and characterization of selective inhibitory chemical probes of SF-1 by a rational ultra-high-throughput screening (uHTS) strategy. A set of 64,908 compounds from the National Institute of Health's Molecular Libraries Small Molecule Repository was screened in a transactivation cell-based assay employing a chimeric SF-1 construct. Two analogous isoquinolinones, ethyl 2-[2-[2-(2,3-dihydro-1,4-benzodioxin-7-ylamino)-2-oxoethyl]-1-oxoisoquinolin-5-yl]oxypropanoate (SID7969543) and ethyl 2-[2-[2-(1,3-benzodioxol-5-ylmethylamino)-2-oxoethyl]-1-oxoisoquinolin-5-yl]oxypropanoate and (SID7970631), were identified as potent submicromolar inhibitors, yielding ...

2008-03-11

145

Edge biasing in the WEGA stellarator  

Energy Technology Data Exchange (ETDEWEB)

The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The focus of this work is ...

2009-02-27

146

Analysis and design of an ultra-high-temperature, hydrogen-fueled MHD generator as an open cycle power supply  

Energy Technology Data Exchange (ETDEWEB)

The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation, and through the ...

1990-01-01

147

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

148

Effect of energy and dose on transient-enhanced diffusion and defect microstructure in low energy high dose As{sup +} implanted Si  

Energy Technology Data Exchange (ETDEWEB)

(001) CZ silicon wafers were implanted with arsenic (As{sup +}) at energies of 10--50 keV to doses of 2 {times} 10{sup 14} to 5 {times} 10{sup 15}/cm{sup 2}. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including ...

1997-11-01

149

Effect of energy and dose on transient-enhanced diffusion and defect microstructure in low energy high dose As"+ implanted Si  

International Nuclear Information System (INIS)

(001) CZ silicon wafers were implanted with arsenic (As"+) at energies of 10--50 keV to doses of 2 x 10"1"4 to 5 x 10"1"5/cm"2. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of point ...

1996-12-02

150

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % ...

2005-11-23

151

Characterization of arsenic dose loss at the Si/SiO{sub 2} interface  

Energy Technology Data Exchange (ETDEWEB)

Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the ...

2000-03-01

152

Characterization of arsenic dose loss at the Si/SiO_2 interface  

International Nuclear Information System (INIS)

Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the ...

2000-03-01

153

Studies on inherited sterility induced in the progeny of gamma irradiated cotton leaf worm, Spodoptera littorals (Boisd.)  

International Nuclear Information System (INIS)

Full - grown pupae of the cotton leaf worm Spodoptera littorals (Boisd.) were gamma - irradiated with low doses of 25,50,75, or 100 Gy for male line and with 50 or 100 Gy for female line . The effects on reproduction, development and sex ratio were the biological aspects studied among P1,F1,F2 and F 3 generations . Also, the effects of dose accumulation applied grown male pupae through two or three filial generations and the retarded influence on their F1,F2,and F 3 progeny were examined. In another trial the histological examinations for ovaries and testes of irradiated parents and for their generation were made . The F1 males were more sterile than irradiated parental males while F1 females were more fertile than their irradiated parental females. Irradiation of P1 males did not clearly affect neither the percentage of mated females nor the average number of spermatophores per mated female among the individuals of P1,F1,F2 and F 3 ...

154

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance ...

2010-06-15

155

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values ...

2010-06-01

156

XPS/AES Study of Electrical and Chemical Properties of Pd/SiC Interface  

Science.gov (United States)

Silicon carbide (SiC) based electronic devices are of great importance for applications under the condition of high temperature, high power and high radiation. Schottky diodes of Palladium/SiC are good candidates for hydrogen and hydrocarbon gas sensors at elevated temperature. The detection sensibility of the diodes has been found heavily temperature dependent. In this work, the electrical and chemical properties of Pd/SiC Schottky contacts were studied by XPS and AES at different annealing temperatures. Schottky diodes were made by depositing ultra-thin palladium films onto a silicon carbide substrate. No significant change in the Schottky barrier height of the Pd/SiC contact was found in the temperature range of 300-673K. Palladium diffusion into SiC and the formation of palladium silicides were observed at room temperature and became significant at 300^oC and higher temperature. The mechanism of ...

1997-11-01

157

Ultra high-speed (508 MHz) beam position digital feedback system  

Energy Technology Data Exchange (ETDEWEB)

The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters ...

1997-02-01

158

The effects of sacrificial coatings on hydrogen embrittlement and re-embrittlement of ultra high strength steels  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an investigation of electrodeposited Zn-14% Ni and aluminium-based SermeTel 1140/962 coatings as possible replacements for cadmium. Slow strain rate tests were performed to measure the extent of direct hydrogen embrittlement of a high strength steel substrate as a result of the coating process and of hydrogen re-embrittlement caused by coating corrosion. The level of re-embrittlement was shown to depend on both the electrochemical potential of the coating and its barrier properties. Zn-14% Ni coatings caused the most re-embrittlement as they had the most active potential and contained through-thickness defects which left the steel exposed to hydrogen uptake. The microstructure of the high strength steel was also shown to be an important factor affecting the extent of embrittlement. AerMet 100 steel was more resistant than 300M steel and this was attributed to the presence of reverted austenite surrounding the martensite ...

2008-04-15

159

Reducing the costs of ultrapure water production - a case study  

Energy Technology Data Exchange (ETDEWEB)

The 380 MW combined cycle gas turbine power station in Peterborough changed its water supply from town mains to high purity reverse osmosis permeate in October 2000. The high purity water is produced from secondary treated sewage effluent using advanced membrane technology. Alpheus Environmental and British Gas staff have recently completed a study of the power station's demineralization plant to identify the differences in operating costs associated with the change in feedwater. The results show that the ultrapure water produced after the change to a high purity feed is of improved quality and that the demineralization plant regeneration operating costs have been reduced by over 90%. The demineralization plant availability has increased from 78 to 98% enabling almost 20% more ultra pure water to be produced. The change in feedwater has also improved the local environment by significantly ...

2002-02-01

160

Microstructural and mechanical characterization of high energy ball milled and sintered WC-10wt%Co-xTaC nano powders  

British Library Electronic Table of Contents (United Kingdom)

Ultra fine tungsten carbide and cobalt powders were milled by high energy planetary ball mill at different ball to powder weight ratios (BPR) to produce particles of WC-10wt%Co hard metal in nanometer scale size. Microstructural characterizations by TEM show that the particle size of tungsten carbide was achieved to 32nm after milling at 15 BPR during 10h. In order to reduce the WC grain growth during the sintering process, tantalum carbide was added to the hard metal as a WC grain growth inhibitor. The nano hard metal powders were compacted at 200MPa pressure and sintered at 1370-1450degreeC temperatures in a high purity hydrogen atmosphere. The results show that the addition of 0.6wt% of TaC improves the hardness and fracture toughness from 1493 HV30 and 11.8MPam (for TaC free sample) to...

2009-01-01

161

Acidic and neutral polar NSO compounds in Smackover oils of different thermal maturity revealed by electrospray high field Fourier transform ion cyclotron resonance mass spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Negative ion electrospray ionization (ESI) coupled with high field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) allows for the direct detection of acidic NSO compounds in petroleum. The technique requires no chromatographic separation, is able to distinguish 18 different compound classes (e.g., neutral nitrogen, carboxylic acids and oxygenates), and can identify {approx}14,000 distinct masses by ultra-high mass resolution and mass accuracy. We previously studied three crude oils from different geological origins [Organic Geochemistry 33 (2002b) 743-759]. Here, we expand our research by comparing two source-equivalent Smackover oils of different levels of thermal maturity. We observe clear differences in the distribution of NSO compound classes, types (number of rings plus double bonds within a class), and number of alkyl carbons. With increasing thermal stress, the relative amount of sulfur and oxygen containing ...

2004-07-01

162

Radiotherapy in the management of Kaposi's sarcoma: comparison of 8 Gy versus 6 Gy.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To evaluate prospectively the efficacy of a single fraction of high-dose radiotherapy in patients with Kaposi's sarcoma. PATIENTS: Between 1994 and 2004, 47 patients with Kaposi's sarcoma...Full Text Available

2006-07-01

163

Hepatotoxicity of High Oral Dose (-)-Epigallocatechin-3-Gallate in Mice  

UK PubMed Central (United Kingdom)

The tea polyphenol (-)-epigallocatechin-3-gallate (EGCG) has been studied for chronic disease preventive effects, and is marketed as part of many dietary supplements. However, case reports have...Full Text Available

2010-01-01

165

Interstitial injection in silicon after high-dose, low-energy arsenic implantation and annealing  

International Nuclear Information System (INIS)

In this work, we investigate the interstitial injection into the silicon lattice due to high-dose, low-energy arsenic implantation. The approach consists in monitoring the diffusion of the arsenic profile as well as of the boron profile in buried #delta#-doped layers, when amounts of the as-implanted arsenic profile are removed by low-temperature wet silicon etching. The experimental results indicate that the contribution of the implantation damage to the transient enhanced diffusion of boron, and thus the interstitial injection, is not the main one. On the contrary, interstitial generation due to arsenic clustering seems to be more important for the present conditions.

2005-11-14

166

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

167

Inhibition of Metabolism of Diethylene Glycol Prevents Target Organ Toxicity in Rats  

British Library Electronic Table of Contents (United Kingdom)

Diethylene glycol (DEG) is an industrial chemical, the misuse of which has led to numerous epidemic poisonings worldwide. The mechanism of its toxicity has not been defined as to the precise relationship between the metabolism of DEG and target organ toxicity. The purpose of this study was to investigate the mechanism for the acute toxicity of DEG, and the effect of the alcohol dehydrogenase inhibitor 4-methylpyrazole (fomepizole), by determining the relationship between accumulation of DEG or its metabolites and the resulting kidney and liver toxicity. Rats were treated by oral gavage with water, 2 g/kg DEG (low dose), 10 g/kg DEG (high dose), or 10 g/kg DEG + fomepizole, and blood and urine were collected over 48 h. Rats treated with high-dose DEG had metabolic acidosis, increased BUN an...

2010-01-01

168

A 4-week oral toxicity study of an antiviral drug combination consisting of arbidol and acetaminophen in rats.  

Science.gov (United States)

The antiviral drug combination consisting of arbidol and acetaminophen was investigated for its 4-week repeated oral administration in Sprague-Dawley rats. Groups of rats (10/sex in low-dose group, 15/sex in other three groups) were given at doses of 0, 200, 400, and 800 mg/kg/day. Clinical signs, mortality, body weight, food consumption, hematology, clinical biochemistry, macroscopic findings, organ weights, and histopathology were examined. The administration resulted in increased incidence of piloerection in most of the high-dose females and in some of the high-dose males and mid-dose females. Histopathological examinations revealed minor treatment-related change in the stomach of the high-dose animals. A decrease in body-weight gains and an increase in liver weight were observed in the mid- and high-dose groups. These treatment-related ...

2010-07-01

169

COMPARISON OF NATURAL BACKGROUND DOSE RATES FOR RESIDENTS OF THE AMARGOSA VALLEY, NV, TO THOSE IN LEADVILLE, CO, AND THE STATES OF COLORADO AND NEVADA  

Energy Technology Data Exchange (ETDEWEB)

In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the dose rate in the ...

2006-02-24

170

High performance polymer electrolyte fuel cells with ultra-low Pt loading electrodes prepared by dual ion-beam assisted deposition  

International Nuclear Information System (INIS)

Ultra-low pure Pt-based electrodes (0.04-0.12 mg_P_t/cm"2) were prepared by dual ion-beam assisted deposition (dual IBAD) method on the surface of a non-catalyzed gas diffusion layer (GDL) substrate. Film thicknesses ranged between 250 and 750 A, these are compared with a control, a conventional Pt/C (1.0 mg_P_t_(_M_E_A_)/cm"2, E-TEK). The IBAD electrode constituted a significantly different morphology, where low density Pt deposits (largely amorphous) were formed with varying depths of penetration into the gas diffusion layer, exhibiting a gradual change towards increasing crystalline character (from 250 to 750 A). Mass specific power density of 0.297 g_P_t/kW is reported with 250 A IBAD deposit (0.04 mg_P_t/cm"2 for a total MEA loading of 0.08 mg_P_t/cm"2) at 0.65 V. This is contrasted with the commercial MEA with a loading of 1 mg_P_t_(_M_E_A_)/cm"2 where mass specific power density obtained was 1.18 g_P_t/kW (at 0.65 V), a value typical of current state of the ...

2006-06-05

171

Strategy for population protection at the end of the emergency phase: the C.o.d.i.r.p.a. view; Strategie de protection des populations a l'issue de la phase d'urgence: reflexions du Codirpa  

Energy Technology Data Exchange (ETDEWEB)

In the case of a serious accident and as a precautionary measure, several protection actions can be implemented by the prefect during the emergency phase. In France the levels of intervention are given by a ministerial decree of the 13. october 2003, resuming recommendations of the International Atomic Energy Agency. The selected values are: an efficient dose of 10 mSv for the stake under cover and in the listening: the concerned persons have to put under cover in a building, any openings carefully closed and stay in the listening of the orders of the prefect; an efficient dose of 50 mSv for evacuation; an efficient dose to the thyroid of 100 mSv for the taking of stable iodine tablets. In order to help the authorities to choose between the keeping of populations at their place or immediate evacuation the decision criteria are: if the forecasted efficient dose of the first month is under 1 mSv, the ...

2008-07-15

172

Strategy for population protection at the end of the emergency phase: the C.o.d.i.r.p.a. view  

International Nuclear Information System (INIS)

In the case of a serious accident and as a precautionary measure, several protection actions can be implemented by the prefect during the emergency phase. In France the levels of intervention are given by a ministerial decree of the 13. october 2003, resuming recommendations of the International Atomic Energy Agency. The selected values are: an efficient dose of 10 mSv for the stake under cover and in the listening: the concerned persons have to put under cover in a building, any openings carefully closed and stay in the listening of the orders of the prefect; an efficient dose of 50 mSv for evacuation; an efficient dose to the thyroid of 100 mSv for the taking of stable iodine tablets. In order to help the authorities to choose between the keeping of populations at their place or immediate evacuation the decision criteria are: if the forecasted efficient dose of the first month is under 1 mSv, the ...

2008-07-01

173

Weldability of high strength Ni-based alloy USC141 as boiler tube for 700 C USC plant  

Energy Technology Data Exchange (ETDEWEB)

Recently the increase of steam temperature and pressure of power plant is required to enhance the thermal efficiency and reduce the CO{sub 2} emission. For the application to advanced USC (Ultra Super Critical) boiler with steam temperature around 700 C, the application of Ni-based alloy such as Alloy617 will be necessary. A new Ni-based alloy USC141 (20Cr-10Mo-2Ti-Al-bal.Ni) with excellent creep rupture strength and low thermal expansion has been developed by Hitachi Ltd. and Hitachi Metals Ltd. as the candidate material for 700 C USC turbine components. In present work, to investigate the possibility for boiler tube application of USC141, its weldability and high temperature strength properties were experimentally examined. The tested material as solution-treated condition shows higher creep rupture strength than that of Alloy617. GTAW (Gas Tungsten Arc Welding) trials of tubular specimen using NIMONIC263 filler wire were conducted ...

2007-07-01

174

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new set of transducers, ...

2009-09-14

175

Review of Central Research Institute of Electric Power Industry. Coal utilization technology harmonious with the environment. Kankyou ni yasashii sekitann riyo gijyutu. Kankyo ni yasashii sekitan riyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Studies are made on coal in terms of its effective utilization, coal cleaning, fluidization and production of new fuel, and issues globally raised. Coal is abundant in reserves and high in supply stability and economic efficiency. However, it is much in CO2 emission per calorific value. To control as much CO2 emission as possible, effective utilization such as increasing of power generation efficiency has been proceeded with. In addition to ultra supercritical pressure and fluidized bed combustion, cited are coal gasification combined cycle power generation and high temperature type fuel cell. Coal has 5-20% ash and impurities like sulfur/nitrogen. Coal should be used clean by pollution abatement measures such as dust collecting, desulfurization and denitrification. Japan is at a world top level of these technologies. Coal is solid, and therefore, is more difficult to handle than liquid fuel. To use it easily, coal is ...

1994-04-25

176

Research and development project in fiscal 1989 for fundamental technologies for next generation industries. Achievement report on research and development on photoreactive materials (Research on function separating type photochromic materials); 1989 nendo hikari hanno zairyo no kenkyu kaihatsu seika hokokusho. Kino bunrigata photochromic zairyo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Research and development has been performed on photochromic materials expected to be used in ultra-high density recording, high resolution indication and photoswitches. With regard to molecular orientation in the ternary system mixed LB film, the result of structural analysis by XPM spectrum revealed that the acceptor constituent in the LB film is so structured that it is separated and laminated with two other constituents, and that the sensitizer constituent and the donor constituent are not recognized of being separated definitely. Regarding the electron movement reaction in the solid phase system, a photo-current measuring experiment was carried out on the laminated film which is vacuum-deposited with the ternary system comprising of the donor, sensitizer, and acceptor. It was concluded that the observed photo-current reflects the electron movement reaction in the solid phase as it is. For the photo-current in the LB film, increase in the ...

1990-03-01

177

Production of ultra high strength steels by turbulent water cooling equipment (TWICE); Production d'aciers haute resistance par un dispositif de refroidissement a turbulence controlee  

Energy Technology Data Exchange (ETDEWEB)

A new industrial process allowing to reach very high cooling rates in the cooling section after soaking of a continuous annealing line for steel sheets is presented. This process constitutes the successful conclusion of a long term research programme, jointly carried out at CRM and Arcelor Cockerill-Sambre for three years, including laboratory experiments, pilot scale trials and several industrial campaigns. It is running on from developments performed in the framework of the HOWAQ (Hot Water Quench) process. The process successively combines a moderate cooling step (600 deg C/s for 0.8 mm thick strips), in boiling water, and a faster cooling step (above 700 deg C/s), by impinging turbulent cold water in a box. Its main features are simplicity, resulting from advanced developments, soundness, flexibility and cooling homogeneity. As treated steel products are characterized by improved mechanical properties, outstanding surface quality (corrosion resistance) and ...

2003-08-01

178

Potentials of biofuels  

Energy Technology Data Exchange (ETDEWEB)

This paper discussed the potential of biofuels with particular reference to the situation in Germany and Europe. Emphasis was on technical potential, such as biofuel production, utilization and environmental aspects. The Institute of Agricultural Technology and Biosystems Engineering ran vTI emission tests on diesel engines to evaluate the environmental impacts of biofuels. This testing facility is able to drive heavy-duty diesel engines in both stationary and dynamic test cycles, such as the European ESC and ETC. Additional analyses were conducted to determine the fine and ultra-fine particles, polycyclic aromatic hydrocarbons (PAH), aldehydes, ketones, and the usual regulated exhaust gas compounds. Ames tests were conducted to assess the mutagenic potential of tailpipe emissions. Previous study results showed that neat vegetable oils can render the exhaust high in mutagenic potency. Some of the non-regulated exhaust gas compounds were found ...

2010-07-01

179

Fiscal 1997 report of the R and D result of industrial science and technology. R and D on synergy ceramics (development of rational energy use technology); 1997 nendo sangyo kagaku gijutsu kenkyu kaihatsu seika hokokusho. Synergy ceramics no kenkyu kaihatsu (energy shiyo gorika gijutsu kaihatsu)  

Energy Technology Data Exchange (ETDEWEB)

For rational use of energy resources, the process technology which allows harmonization and multiplication of conflicting characteristics was developed for development of new ceramic system materials. This paper summarizes the result in fiscal 1997. On a structural reaction process among creation technologies of ultra-reliable structure, study was made on structure control and hot-working technology through atmosphere control in ceramics synthesis. On basic technology for analysis and evaluation, study was made on the effect of particle bridging on strengthening and toughening of ceramic materials. Study was also made on a toughness expression mechanism, FEM model analysis of particle bridging, and crack growth resistance of ceramics. On control of solid solution precipitation, new alumina ceramics with high strength, hardness and wear resistance was obtained by transgranularly precipitating nano-size particles from a fine-grain ...

1998-03-01

180

Energy-filtered electron microscopy for imaging core-shell nanostructures  

Energy Technology Data Exchange (ETDEWEB)

CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the core-shell arrangements in the nanoparticle ...

2008-08-15

181

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in ...

2003-10-01

182

Atomistic modeling of the effects of dose and implant temperature on dopant diffusion and amorphization in Si  

International Nuclear Information System (INIS)

We discuss atomistic simulations of ion implantation and annealing of Si over a wide range of ion dose and substrate temperatures. The DADOS Monte Carlo model has been extended to include the formation of amorphous regions, and this allows simulations of dopant diffusion at high doses. As the dose of ions increases, the amorphous regions formed by cascades eventually overlap, and a continuous amorphous layer is formed. In that case, most of the excess interstitials generated by the implantation are swept to the surface as the amorphous layer regrows, and do not diffuse in the crystalline region. This process reduces the amount of transient enhanced diffusion (TED) during annealing. This model also reproduces the dynamic annealing during high temperature implants. In this case, the local amorphous regions regrow as the implant proceeds, without the formation of a continuous amorphous ...

2001-06-01

183

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at ...

1976-01-01

184

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the ...

2007-03-15

185

Chain radiation-chemical cross-linking of polyethylene under high pressures. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Regularities in the radiation cross-linking of low-density polyethylene under various conditions of ..gamma..-irradiation were studied. It is shown that at the 0.5 GPa pressure and 450 K the gel formation is initiated at doses of about 1 kGy, i.e. at doses 10 times as low as compared to normal conditions. Abnormally high rate of radiation cross-linking at high temperature and high pressure is an evidence of changes in the mechanism of polyethylene, radiation cross-linking, i.e. of the process transition from nonchain to chain conditions. Decrease in the potential barriers of macroradical reactions with macromolecules is the most probable reason of change in the polymer cross-linking nature.

1984-01-01

186

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...

187

Experimental and theoretical studies of nuclear generation of ozone from oxygen and oxygen--sulfur hexafluoride mixtures  

International Nuclear Information System (INIS)

A series of experimental measurements of the yield of O_3 in nuclear-induced O_2 and O_2-SF_6 discharges are reported. The discharges were created by bombardment with energetic particles from the "1"0B(n,#alpha#)"7Li reaction. Continuous irradiation at dose rates of 10"1"5--10"1"7 eV cm"-"3 s"-"1 and pulsed irradiation (--10 ms FWHM) at a peak dose rate of --10"2"0 eV cm"-"3 s"-"1 were conducted. At the lower dose rates, the addition of SF_6 generally increased the ozone yield due to the slowing of ozone destruction by negative oxygen and ozone ions. In contrast, at the high dose rates, the ozone concentration decreased due to SF_6 suppression of atomic oxygen formation by ion--ion recombination. A numerical model was developed and tested against experimental conditions. This model indicates that the steady-state ozone concentration was limited by the reaction ...

188

Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was ...

2005-11-23

189

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic ...

1989-08-15

190

Multiple courses of high-dose total skin electron beam therapy in the management of mycosis fungoides  

International Nuclear Information System (INIS)

Purpose: A retrospective analysis was undertaken to determine the indications for, the efficacy of, and the long-term complications of two courses of total skin electron beam therapy for mycosis fungoides. Methods and Materials: A retrospective analysis of 15 patients with the pathologic diagnosis of mycosis fungoides treated in the Department of Radiation Oncology at Stanford University Medical Center between 1968 and 1990 was performed. All patients received two courses of high-dose electron beam therapy to the skin. The mean dose for the total skin treatment for the first course was 32.6 Gy and 23.4 Gy for the second course of treatment. Results: Following the first course of total skin electron beam therapy, 11 of 15 had a complete response, with a mean duration of 11.6 months. All patients received adjuvant therapies between the first and second courses of high-dose total skin electron beam therapy. The mean interval ...

1995-07-30

191

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are ...

1999-05-01

192

Optimizing an analytical dose calculation algorithm for fast 2D calculations  

International Nuclear Information System (INIS)

Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the ...

193

Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection  

Energy Technology Data Exchange (ETDEWEB)

To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ambient neural activity during radiation ...

1990-05-01

194

Intracavity irradiation with deferred radioactive load technique, remote control high activity sources  

Energy Technology Data Exchange (ETDEWEB)

From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via ...

1988-01-01

195

The use of steroids in the treatment of severe sepsis and septic shock  

British Library Electronic Table of Contents (United Kingdom)

Sepsis and septic shock remain major causes of mortality and morbidity worldwide. Previously, high dose corticosteroids were used to dampen the inflammatory response but studies and meta-analyses showed this to be of no benefit and possibly detrimental. Subsequently, low dose corticosteroids were used in the treatment of sepsis and septic shock with the hypothesis that these conditions are associated with relative adrenal insufficiency. Although some studies showed promising results larger studies and meta-analyses have failed to reproduce these effects and the use of corticosteroids in the treatment of sepsis and septic shock remains controversial. We review the current literature and guidelines regarding low dose corticosteroid use in the management of sepsis and septic shock.

2011-01-01

196

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

197

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

198

Inflammatory Biomarkers of Sulfur Mustard Analog 2-Chloroethyl Ethyl Sulfide-Induced Skin Injury in SKH-1 Hairless Mice  

British Library Electronic Table of Contents (United Kingdom)

Sulfur mustard (HD) is an alkylating and cytotoxic chemical warfare agent, which inflicts severe skin toxicity and an inflammatory response. Effective medical countermeasures against HD-caused skin toxicity are lacking due to limited knowledge of related mechanisms, which is mainly attributed to the requirement of more applicable and efficient animal skin toxicity models. Using a less toxic analog of HD, chloroethyl ethyl sulfide (CEES), we identified quantifiable inflammatory biomarkers of CEES-induced skin injury in dose- (0.05-2 mg) and time- (3-168 h) response experiments, and developed a CEES-induced skin toxicity SKH-1 hairless mouse model. Topical CEES treatment at high doses caused a significant dose-dependent increase in skin bi-fold thickness indicating edema. Histopathological e...

2009-01-01

199

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

200

A radiation monitoring system for nuclear fusion devices  

International Nuclear Information System (INIS)

Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)

2005-12-01

201

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations  

International Nuclear Information System (INIS)

The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam ...

2006-09-01

202

Formation of high resistivity regions in [ital p]-type Al[sub 0. 5]In[sub 0. 5]P by ion implantation  

Science.gov (United States)

Ion implantation has been applied to magnesium-doped Al[sub 0.5]In[sub 0.5]P to produce high resistivity regions for the first time. Hydrogen, oxygen, and argon ions were implanted at a base dose ranging from 5[times]10[sup 12] to 5[times]10[sup 14] cm[sup [minus]2] and annealed from 400 to 900 [degree]C. Hydrogen did not appreciably compensate the In[sub 0.5]Al[sub 0.5]P layer while oxygen and argon produced sheet resistances up to 1[times]10[sup 9] [Omega]/[open square]. After annealing at 800 [degree]C, regions with high dose oxygen implants maintained a sheet resistance above 1[times]10[sup 7] [Omega]/[open square], while regions with high dose argon implants recovered most of the unimplanted conductivity.

1993-12-06

203

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

204

On the effects of low radiation doses  

International Nuclear Information System (INIS)

The prevailing hypothesis of linear extrapolation from high to low radiation doses without any threshold level is being questioned more and more strongly for radiobiological and epidemiological reasons and, consequently, also on socio-economic and ethical grounds. A cost-benefit analysis based on scientific facts and made plausible to the general public, concentrating on a comparison with demonstrable natural and manmade risks, most probably would result not only in the permissible limits being raised by a considerable margin, but also in billions of costs saved, and in greater acceptance of all peaceful uses of radiation, nuclear power included. (orig.)

1998-10-01

205

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

206

Gastrointestinal absorption of transuranic elements by rats  

International Nuclear Information System (INIS)

Absorption of ''organically bound'' "2"3"3U and "2"4"1Am from gastrointestinal tracts of adult rats was twice that of the inorganic nitrate form. There was no difference between transport of "2"3"2U and "2"3"3U by adult rats, but "2"3"2U absorption by newborn rats was four times that of "2"3"3U. Absorption of "2"3"8Pu nitrate through the gut of the newborn is relatively insensitive to dose but incorporation in the gut mucosa saturates at high dose levels. Absorption of "2"3"8Pu is greater at 4 hr of age than at 24 hr.

1977-05-01

207

Application of high energy ion beam for the control of boron diffusion  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10{sup 15} to 1 x 10{sup 16} cm{sup -2}. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.

2006-01-15

208

Application of high energy ion beam for the control of boron diffusion  

International Nuclear Information System (INIS)

For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10"1"5 to 1 x 10"1"6 cm"-"2. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.

2006-01-01

209

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

210

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in ...

2010-01-01

211

Ultra-high tritium decontamination of simulated fusion fuel exhaust using a 2-stage palladium membrane reactor  

Energy Technology Data Exchange (ETDEWEB)

A 2-stage cold (non-tritium) PMR system was tested with the ITER mix in61 days of continuous operation. No decrease in performance was observed over the duration of the test. Decontamination factor (DF) was found to increase with decreasing inlet rate. Decontamination factors in excess of 1.4 {times} 10{sup 5} were obtained, but the exact value of the highest DF could not be determined because of analysis limitations. Results of the 61-day test were used to design a 2-stage PMR system for use in tritium testing. The PMR system was scaled up by a factor of 6 and built into a glovebox in the Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory. This system is approximately 1/5th of the expected full ITER scale. The ITER mix was injected into the PMR system for 31 hours, during which 4.5 g of tritium were processed. The 1st stage had DF = 200 and the 2nd stage had DF = 2.9 {times} 10{sup 6}. The overall DF = 5.8 {times} 10{sup 8}, which is greater than ITER ...

1996-12-31

212

Ultra-high tritium decontamination of simulated fusion fuel exhaust using a 2-stage palladium membrane reactor  

International Nuclear Information System (INIS)

A 2-stage cold (non-tritium) PMR system was tested with the ITER mix in 61 days of continuous operation. No decrease in performance was observed over the duration of the test. Decontamination factor (DF) was found to increase with decreasing inlet rate. Decontamination factors in excess of 1.4x10"5 were obtained, but the exact value of the highest DF could not be determined because of analysis limitations. Results of the 61-day test were used to design a 2-stage PMR system for use in tritium testing. The PMR system was scaled up by a factor of 6 and built into a glovebox in the Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory. This system is approximately 1/5"t"h of the expected full ITER scale. The ITER mix was injected into the PMR system for 31 hours, during which 4.5 g of tritium were processed. The 1"s"t stage had DF =200 and the 2"n"d stage had DF=2.9x10"6. The overall DF=5.8x10"8, which is greater than ITER requirements. 3 refs., 10 figs.

1996-06-16

213

Research on deformation characteristic of AZ31Mg alloy and its constitutive equations  

Energy Technology Data Exchange (ETDEWEB)

Superplasticity of polycrystalline metallic materials is a phenomenon which shows hundreds to thousands of percents of large plastic deformation without necking in a steady state of low stress, when the uni-axial tensile loading is done in some special thermo-mechanical conditions (some limited ranges of properly high temperature and low strain rate). The main mechanism of superplastic phenomenon is the grain boundary sliding, while the main mechanism of usual plastic deformation is the trans-granular sliding. In this research, the possibility of superplastic deformation in a magnesium alloy (AZ31Mg alloy) was experimentally investigated, because generally speaking, the magnesium alloy whose atomic structure is hexagonal does not have enough formability in a form of trans-granular sliding mechanism. In this paper, the detail of experimental results are shown and discussed. Moreover, the constitutive equations of Mg alloy are proposed on the basis of the ...

2004-07-01

214

Monitoring power plant fireside corrosion using corrosion probes  

Energy Technology Data Exchange (ETDEWEB)

The ability to monitor the corrosion degradation of key components in fossil fuel power plants is of utmost importance for Futuregen and ultra-supercritical power plants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive conditions. In such a case, corrosion rate could become a process control variable that directs the operation of a coal combustion or ...

2005-01-01

215

Mechanical properties of Fe -10Ni -7Mn martensitic steel subjected to severe plastic deformation via cold rolling and wire drawing  

Energy Technology Data Exchange (ETDEWEB)

Fe-Ni-Mn martensitic steels are one of the major groups of ultra-high strength steels that have good mechanical properties and ductility in as annealed condition but they suffer from severe inter-granular embitterment after aging. In this paper, the effect of heavy shaped cold rolling and wire drawing on the mechanical properties of Fe-Ni-Mn steel was investigated. This process could provide a large strain deformation in this alloy. The total strain was {epsilon} {approx}7. Aging behavior and tensile properties of Fe-10Ni-7Mn were studied after aging at 753 K. The results showed that the ultimate tensile strength and ductility after cold rolling, wire drawing and aging increased up to 2540 MPa and 7.1 %, respectively, while the conventional steels show a premature fracture stress of 830 MPa with about zero ductility after aging.

2010-07-01

216

Mechanical properties of Fe -10Ni -7Mn martensitic steel subjected to severe plastic deformation via cold rolling and wire drawing  

International Nuclear Information System (INIS)

Fe-Ni-Mn martensitic steels are one of the major groups of ultra-high strength steels that have good mechanical properties and ductility in as annealed condition but they suffer from severe inter-granular embitterment after aging. In this paper, the effect of heavy shaped cold rolling and wire drawing on the mechanical properties of Fe-Ni-Mn steel was investigated. This process could provide a large strain deformation in this alloy. The total strain was #epsilon# #approx#7. Aging behavior and tensile properties of Fe-10Ni-7Mn were studied after aging at 753 K. The results showed that the ultimate tensile strength and ductility after cold rolling, wire drawing and aging increased up to 2540 MPa and 7.1 %, respectively, while the conventional steels show a premature fracture stress of 830 MPa with about zero ductility after aging.

2010-07-01

217

Lyman-alpha emitters as tracers of the transitioning Universe  

CERN Document Server

Of the many ways of detecting high redshift galaxies, the selection of objects due to their redshifted Ly-alpha emission has become one of the most successful. But what types of galaxies are selected in this way? Until recently, Ly-alpha emitters were understood to be small star-forming galaxies, possible building-blocks of larger galaxies. But with increased number of observations of Ly-alpha emitters at lower redshifts, a new picture emerges. Ly-alpha emitters display strong evolution in their properties from higher to lower redshift. It has previously been shown that the fraction of ultra-luminous infrared galaxies (ULIRGs) among the Ly-alpha emitters increases dramatically between redshift three and two. Here, the fraction of AGN among the LAEs is shown to follow a similar evolutionary path. We argue that Ly-alpha emitters are not a homogeneous class of objects, and that the objects selected with this method reflect the general star forming ...

2011-01-01

218

Laser stabilization at 1536 nm using regenerative spectral hole burning  

International Nuclear Information System (INIS)

Laser frequency stabilization giving a 500-Hz Allan deviation for a 2-ms integration time with drift reduced to 7 kHz/min over several minutes was achieved at 1536 nm in the optical communication band. A continuously regenerated spectral hole in the inhomogeneously broadened "4I_1_5_/_2(1)#->#"4I_1_3_/_2(1) optical absorption of an Er"3"+:Y_2SiO_5 crystal was used as the short-term frequency reference, while a variation on the locking technique allowed simultaneous use of the inhomogeneously broadened absorption line as a long-term reference. The reported frequency stability was achieved without vibration isolation. Spectral hole burning frequency stabilization provides ideal laser sources for high-resolution spectroscopy, real-time optical signal processing, and a range of applications requiring ultra-narrow-band light sources or coherent detection; the time scale for stability and the compatibility with spectral hole burning devices make ...

2001-04-15

219

Iridium and PGE in sedimentary rocks; Iridium et platinoides dans les roches sedimentaires  

Energy Technology Data Exchange (ETDEWEB)

The detection limit of Instrumental Neutron Activation Analysis (INAA), about a few microgram per kg, is not sufficient to determine iridium concentrations in most geological samples. Use of the coincidence counting of the 316 and 468 keV gamma-rays emitted during the decay of {sup 192}Ir, improved the sensitivity (0.01 microgram per kg). The high iridium content of the clay layers from the Cretaceous-Tertiary transition (KTB) has been considered as an evidence of the extra-terrestrial origin of the KTB mass extinction. However some results indicate that a significant part of the iridium content in sediments has a volcanic origin. Radiochemical Neutron Activation Analysis (RNAA) in some KTB samples and in basic and ultra-basic rocks show that, unlike in volcanic products, no PGE (platinoids) fractionation appears in KTB samples. The nearby chondritic PGE pattern supports an extra-terrestrial origin for the KTB iridium anomaly. 2 figs., 2 tabs., ...

1994-12-31

220

High temperature aluminum electrolytic capacitors for ULEV inverters  

Energy Technology Data Exchange (ETDEWEB)

A comparison between the concepts of the hybrid electric vehicle (HEV) and the ultra low emission vehicle (ULEV) was presented. The ULEV uses a much larger engine compared to the HEV, but it uses a lower Kw generator/motor and inverter/charger to use the latest engine and battery technology. The underlying goal of the ULEV is to supply auxiliary power under start-up and heavy load conditions and to remove indirect systems such as steering, starting and blower control from the engine via small electric drives. The challenge is to build a ULEV that is robust enough to withstand any environmental conditions. Since the ULEV engine is larger, it can experience compartment temperatures greater than 125 degrees C, which limits the use of conventional filter capacitors. Nippon Chemi-Con has recently developed U787D, the world's first continuous 150 degrees C rated aluminum electrolytic capacitor designed to meet the ambient, ripple currents and vibration ...

2000-07-01

221

High performance ultra-steels with recyclable design  

Energy Technology Data Exchange (ETDEWEB)

The global production of steel is predicted to increase rapidly to meet future demands. In order to conserve the natural resources, certain measures must be taken. These include perfecting the recycling of steel, improving the performance to extend the life of the material, and reduce the need for massive production of steel by increasing the strength of the material. This paper presented a design concept for ultrafine complex microstructure steel. The National Research Institute for Metals in Japan has worked on a project which investigated 800 MPa ferrite steel for welded structures with a chemical composition similar to 400 MPa-class plain carbon steel. The doubled strength was attributed to grain refinement. Novel welding techniques were also used for joining the ultrafine microstructure. In this study, low carbon Si-Mn ferrite-pearlite steels were subjected to a thermo-mechanical treatment to produce a microstructure of 1 micron order ultrafine grain ferrite plus finely dispersed ...

2000-07-01

222

Hard, infrared black coating with very low outgassing  

Energy Technology Data Exchange (ETDEWEB)

Infrared astronomical instruments require absorptive coatings on internal surfaces to trap scattered and stray photons. This is typically accomplished with any one of a number of black paints. Although inexpensive and simple to apply, paint has several disadvantages. Painted surfaces can be fragile, prone to shedding particles, and difficult to clean. Most importantly, the vacuum performance is poor. Recently a plasma enhanced chemical vapor deposition (PECVD) process was developed to apply thick (30 {micro}m) diamond-like carbon (DLC) based protective coatings to the interior of oil pipelines. These DLC coatings show much promise as an infrared black for an ultra high vacuum environment. The coatings are very robust with excellent cryogenic adhesion. Their total infrared reflectivity of < 10% at normal incidence approaches that of black paints. We measured outgas rates of <10{sup -12} Torr liter/sec cm{sup 2}, comparable to bare ...

2008-06-02

223

Future limits on isotropic Lorentz violation in the photon sector from UHECRs and TeV gamma rays  

CERN Document Server

Present and future ultra-high-energy-cosmic-ray facilities (e.g., the Pierre Auger Observatory with South and North components) and TeV-gamma-ray telescope arrays (e.g., HESS/VERITAS and CTA) have the potential to set stringent indirect bounds on the nine Lorentz-violating parameters of nonbirefringent modified Maxwell theory minimally coupled to standard Dirac theory. Theoretically, the most interesting case is isotropic Lorentz violation, which is described by a single parameter [taken to vanish for the case of the standard Lorentz-invariant theory]. It appears possible to obtain in the future an upper (lower) indirect bound on this single isotropic Lorentz-violating parameter at the +10^{-21} (-10^{-17}) level. Comparison is made with existing and future direct bounds from laboratory experiments. The possible physics implications of upper bounds at the 10^{-21} level are also briefly discussed.

2011-01-01

224

First plasma experiment on spherical tokamak device UTST  

International Nuclear Information System (INIS)

The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasma obtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma obtained 10 kA by using only outer PF coils and single ST was generated at the lower area (z=-0.3 - -1.0[m]) close to a washer gun. This result suggests that another washer gun on the top of ...

2009-04-01

225

FIB implantation induced site-selectively grown self-assembled InAs QDs in a light emitting #mu#-diode  

International Nuclear Information System (INIS)

We present an approach for fabrication of intentionally positioned epitaxial InAs QDs in a micron sized light emitting diode. For site-selective growth, a combination of molecular beam epitaxy (MBE) and focused ion beam (FIB) implantation technology in an all-ultra-high-vacuum (UHV) setup has been employed. Single dot occupancy of almost 55 % on FIB patterned nano-depressions was successfully achieved. Thereafter, carrier injection and subsequent radiative recombination from the positioned InAs/GaAs self-assembled QDs was investigated by embedding these QDs in the intrinsic part of a GaAs-based micron sized p-i-n junction device. Few or single dot are expected to be electrically addressed in these devices. We report results from electroluminescence (EL) measurement which proves the single dot characteristics of our device. The EL spectra consist of sharp emission lines and their dependence on injection current shows linear behavior for exciton and quadratic ...

2010-03-21

226

Autosolvent effect of bitumen in thermal cracking; Netsubunkai hanno ni okeru bitumen no jiko yobai koka  

Energy Technology Data Exchange (ETDEWEB)

Tar sand bitumen is petroleum-based ultra-heavy oil, and has a great amount of reserve like coal. However, there are still a lot of problems for its highly effective utilization. This paper discusses whether the light components in bitumen show independent behavior during the thermal cracking of heavy components, or not. Solvent effect and reaction mechanism during the thermal cracking are also derived from the change of their chemical structures. Athabasca tar sand bitumen was separated into light and heavy fractions by vacuum distillation based on D-1660 of ASTM. Mixtures of the both fractions at various ratios were used as samples. Negative effect of the light fraction on cracking of the heavy fraction was observed with dealkylation and paraffin formation Polymerization of the dealkylated light fraction to the heavy fraction was suggested due to lack of hydrogen in the thermal cracking under nitrogen atmosphere, which resulted in the ...

1996-10-28

227

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

228

The denoising of Monte Carlo dose distributions using convolution superposition calculations  

International Nuclear Information System (INIS)

Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to ...

2007-09-07

229

Laser flash effects on chromatic discrimination in monkeys. Final report, April 1986-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Detecting a camouflaged target in a visually noisy background depends on the ability of the observer to discriminate the target from the surrounding terrain. Visible laser irradiation at less than damage levels can act as a masking source by compromising or reducing the observer's ability to resolve differences in the visual scene. Previous research has examined this concept by investigating laser flash effects on: acuity (size discrimination); tracking (motion discrimination); visual sensitivity (color); and contrast sensitivity functions (luminance contrast). In all cases, flashes from continuous-wave (CW) sources have proven more effective visually than pulsed (Q-switched) sources, when compared on peak-energy criteria (i.e., MPE), even though Q-switched lasers induce damage at lower energy doses. Additionally, the inherent safety of ultra-short laser pulses has been questioned. Past animal research has shown that, on the measures ...

1987-10-01

230

SERAPHIM: A propulsion technology for fast trains  

Energy Technology Data Exchange (ETDEWEB)

The Segmented Rail Phased Induction Motor (SERAPHIM) is a compact, pulsed linear induction motor (LIM) offering a unique capability for very high speed train propulsion. It uses technology developed for the Sandia coilgun, an electromagnetic launcher designed to accelerate projectiles to several kilometers per second. Both aluminum cylinders and plates were accelerated to a kilometer per second (Mach 3) by passing through a sequence of coils which were energized at the appropriate time. Although this technology was developed for ultra-high velocity, it can be readily adapted to train propulsion for which, at sea level, the power required to overcome air resistance limits the operational speed to a more modest 300 mph. Here, the geometry is reversed. The coils are on the vehicle and the ``projectiles`` are fixed along the roadbed. SERAPHIM operates not by embedding flux in a conductor, but by excluding it. In this propulsion scheme, pairs of ...

1995-06-01

231

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide ...

2006-08-15

232

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

International Nuclear Information System (INIS)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide ...

2006-08-01

233

Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics  

Energy Technology Data Exchange (ETDEWEB)

The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance to ionizing radiation. Ny 6 and Ny 66 calendered fabrics are ...

2010-03-15

234

Enhanced spectral discrimination through the exploitation of interface effects in photon dose data  

International Nuclear Information System (INIS)

The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a ...

2004-02-01

235

Early and Late Bowel Complication Following Irradiation of Cancer of the Uterine Cervix-Whole Pelvis External Irradiation end High-Dose-Rate Interactively Irradiation  

International Nuclear Information System (INIS)

Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still 44% of patient will develop recurrent cancer This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen which is 500-1000 cGy higher than other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was 46%, but only 1 patient (1%) had operative treatment ...

1989-06-01

236

Comparison of 6 MV and 18 MV photons for IMRT treatment of lung cancer  

International Nuclear Information System (INIS)

Background and purpose: To compare 6 MV and 18 MV photon intensity modulated radiotherapy (IMRT) for non-small cell lung cancer. Materials and methods: Doses for a cohort of 10 patients, typical for our department, were computed with a commercially available convolution/superposition (CS) algorithm. Final dose computation was also performed with a dedicated IMRT Monte Carlo dose engine (MCDE). Results: CS plans showed higher D _9_5_% (Gy) for the GTV (68.13 vs 67.36, p = 0.004) and CTV (67.23 vs 66.87, p = 0.028) with 18 than with 6 MV photons. MCDE computations demonstrated higher doses with 6 MV than 18 MV in D _9_5_% for the PTV (64.62 vs 63.64, p = 0.009), PTV_o_p_t_i_m (65.48 vs 64.83, p = 0.014) and CTV (66.22 vs 65.64, p = 0.027). Dose inhomogeneity was lower with 18 than with 6 MV photons for GTV (0.08 vs 0.09, p = 0.007) and CTV (0.10 vs 0.11, p = 0.045) in CS but not MCDE ...

2007-01-01

237

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

International Nuclear Information System (INIS)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...

2009-10-01

238

Stereotactic body radiotherapy for unresectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical ...

2010-01-01

239

Radiation grafting processes and properties of leathers modified with butyl acrylate  

International Nuclear Information System (INIS)

Conditions for radiation induced grafting with butyl acrylate dispersed in water emulsion onto chrome-tanned pig skins have been worked out for #gamma#-rays and electron beam irradiations. The highest yield of grafting was observed at monomer concentration approximately 25% (w/w), dose equal to 25 kGy and dose rate not exceeding 10 MGy/h. At these conditions the yield of grafting attained a value approximately 25% and content of homopolymer in the leather amounted to 6%. The efficiency of monomer to polymer conversion decreases when the concentration of monomer in emulsion and dose rate increases. Yield of homopolymer is independent of the dose rate. An explanation of the observed relations has been proposed. The physical and used properties of grafted leathers were tested. Radiation processed leathers were found superior to samples finished by traditional methods. One has to point to better tolerance ...

1982-01-01

240

Mechanisms of renal handling of lead  

International Nuclear Information System (INIS)

The relative roles of glomerular filtration, tubular reabsorption and tubular secretion in lead handling were evaluated using renal clearance technique, stop-flow analysis, and renal lead accumulation. In addition, the effect of altering acid-base status on renal handling of Pb was determined. Clearance of ultrafilterable lead was measured in anesthetized dogs during infusion of "2"0"3Pb with small doses of carrier Pb(0.5 to 50 #mu#g/kg/h). Filterable lead concentration was estimated by in vitro ultrafiltration of non-anticoagulated plasma. Fractional excretion of Pb was calculated using creatinine clearance to estimate glomerular filtration rate. Dogs in acute metabolic acidosis had the lowest fractional excretion of ultrafilterable Pb (< 0.1); those in alkalosis had high fractional Pb excretion (0.75 to 2.5) while normal dogs were intermediate (0.1 to .4). The fractional excretion of Pb during metabolic alkalosis varied with the ...

241

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron. [Rapid Thermal Annealing  

Energy Technology Data Exchange (ETDEWEB)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak of precipitated dopants produced during ...

1993-01-01

242

Adaptive response of the chicken embryo to low doses of x-irradiation  

Energy Technology Data Exchange (ETDEWEB)

Chicken embryos were x-irradiated in ovo with 5-30 cGy (=priming dose) at the 13th-15th day of development. After 3-48 h, brain- and liver-cell suspensions were x-irradiated in vitro with (challenge) doses of 4-32 Gy. Significantly less radiation damage was observed when the radiation response was measured by scheduled DNA synthesis, nucleoid sedimentation and viscosity of alkaline cell lysates 12-36 h after the priming exposure. In vivo, pre-irradiation with 10 cGy enhanced regeneration as evidenced by the DNA content of chicken embryo brain and liver 24 h following a challenge dose of 4 Gy. From nucleoid sedimentation analyses in brain and liver cells immediately after irradiation with 16 Gy and after a 30-min repair period in the presence of aphidicolin, dideoxythymidine and 3-aminobenzamide or in the absence of these DNA repair inhibitors, it is concluded that a reduction of the initial radiation damage is the dominant ...

1995-08-01

243

Secondary hazards of high power laser beam welding  

International Nuclear Information System (INIS)

Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)

1996-01-01

244

Demonstration experiment on improved radwaste evaporator  

Energy Technology Data Exchange (ETDEWEB)

High conductivity liquid waste, which is produced in nuclear power plants, is now processed with radwaste evaporator. The concentrated liquid waste in the evaporator is so highly radioactive and corrosive that the improvement on maintenability and reduction of exposure dose rate are desirable as well as high decontamination factor (DF). Fuji Electric constructed the improved experimental facility of evaporator and carried out an experiment to demonstrate DF, maintenability and controllability of system. As the results, DF, maintenability and controllability were proved to be excellent and its applicability to nuclear power plant was well established.

1988-07-01

245

Vacuum container for use in a thermonuclear device  

International Nuclear Information System (INIS)

Purpose: To enable the use of a vacuum container under a relatively high temperature or a high level radioactive dose. Constitution: Vacuum sealing materials for use in a vacuum container are made of resins such as polyimide and polyamide. The sealing materials are joined to the both surfaces of a plate-like insulator by means of adhesives or sealants, or the sealing materials are joined between two plate-like insulators by means of adhesives or sealants. They are situated within grooves of both of flanges, which are clamped tightly by insulation bolt and nut. Since the vacuum sealing materials are joined to the insulator by means of the adhesives or sealants, the reliability of the vacuum sealing can be improved without impairing the electrical insulation. The resin of the vacuum sealing material can be used for the radiation dose up to 10"8 rad, temperature up to 250"0C or more. (Seki, K.).

1982-04-30

246

Monte Carlo characterization of an ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty  

International Nuclear Information System (INIS)

An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.

2006-01-01

247

Long-term mortality and cancer risk in irradiated rhesus monkeys. Interim report, 30 September 1983-15 July 1989  

Energy Technology Data Exchange (ETDEWEB)

Lifetime observations on a group of 358 rhesus monkeys indicate that life expectancy loss from exposure to protons in the energy range encountered in the Van Allen belts and solar proton events is influenced primarily by the dose rather than the energy of radiation. After 24 years, life expectancy losses from similar surface doses of low-LET (138-2300 MeV) and high-LET (32-55 MeV) protons are not significantly different, but the high-LET protons are associated with more deaths in the early years, while the low-LET protons contribute more to mortality in later years. In males, the most significant cause of life shortening is nonleukemia cancers.

1990-05-01

248

Dutch distribution zones of stable iodine tablets based on atmospheric dispersion modelling of accidental releases from nuclear power plants.  

Science.gov (United States)

Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distribution of stable iodine tablets is advised. PMID:20332130

2010-03-23

249

Dutch distribution zones of stable iodine tablets based on atmospheric dispersion modelling of accidental releases from nuclear power plants  

British Library Electronic Table of Contents (United Kingdom)

Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distrib...

2010-01-01

250

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

251

ISDD: A Computational Model of Particle Sedimentation, Diffusion and Target Cell Dosimetry for In Vitro Toxicity Studies  

Energy Technology Data Exchange (ETDEWEB)

Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene ...

2010-11-30

252

Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion  

International Nuclear Information System (INIS)

We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT plan was recalculated ...

2006-10-21

253

Long-term high temperature fatigue properties of new structural materials for nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

This study aims to evaluate fatigue strength properties at long-term high temperature of 316FR steels developed for structural materials applied to high temperature components in the 21st Century such as Demonstration FBR, and to obtain design indicators on high temperature strength properties arranged on chemical composition and grain size on a base of 316FR stainless steels. As results obtained by the study, it could be found that as a result of systematic examinations on temperatures and strain rate dependence on symmetric triangular strain waveform of 316FR steels between 500 to 600degC, temperature of fatigue life, and strain rate dependence can be integrally evaluated by a parameter analysis method developed by authors and life prediction at ultra low strain rate of less than 10{sup -6}/s and its experimental verification could be carried out. And, it was also found that as a result of evaluation ...

2003-01-01

254

Long-term high temperature fatigue properties of new structural materials for nuclear reactors  

International Nuclear Information System (INIS)

This study aims to evaluate fatigue strength properties at long-term high temperature of 316FR steels developed for structural materials applied to high temperature components in the 21st Century such as Demonstration FBR, and to obtain design indicators on high temperature strength properties arranged on chemical composition and grain size on a base of 316FR stainless steels. As results obtained by the study, it could be found that as a result of systematic examinations on temperatures and strain rate dependence on symmetric triangular strain waveform of 316FR steels between 500 to 600degC, temperature of fatigue life, and strain rate dependence can be integrally evaluated by a parameter analysis method developed by authors and life prediction at ultra low strain rate of less than 10"-"6/s and its experimental verification could be carried out. And, it was also found that as a result of evaluation of ...

2003-01-01

255

A study of radiation embrittlement using simulation irradiation  

International Nuclear Information System (INIS)

Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeV electrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage provides additional cluster nucleation sites to compensate for lower free point defect production. High ...

2008-10-13

256

Modeling human risk: Cell & molecular biology in context  

Energy Technology Data Exchange (ETDEWEB)

It is anticipated that early in the next century manned missions into outer space will occur, with a mission to Mars scheduled between 2015 and 2020. However, before such missions can be undertaken, a realistic estimation of the potential risks to the flight crews is required. One of the uncertainties remaining in this risk estimation is that posed by the effects of exposure to the radiation environment of outer space. Although the composition of this environment is fairly well understood, the biological effects arising from exposure to it are not. The reasons for this are three-fold: (1) A small but highly significant component of the radiation spectrum in outer space consists of highly charged, high energy (HZE) particles which are not routinely experienced on earth, and for which there are insufficient data on biological effects; (2) Most studies on the biological effects of radiation to date have been ...

1997-06-01

257

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

258

Population exposure to power-frequency fields: concepts, components, and control  

Energy Technology Data Exchange (ETDEWEB)

There are many sources of population exposures to power-frequency (50/60 Hz) electric and magnetic fields including household appliances and wiring, neighborhood distribution circuits, and high-voltage transmission lines. Bioeffects studies were unable to demonstrate that exposures to power-frequency fields can affect public health. Researcher have likewise been unable to show that the health effects of such exposures are negligible. State and federal regulatory agencies are, therefore, grappling with questions of whether and how to regulate the sitting or design of new extra high-voltage transmission lines so as to control the ground-level fields to which people are exposed. The purpose of this dissertation is to illuminate some of the exposure-related aspects of these question. A taxonomy of the relationship between field encounter and effect is developed to clarify the meaning of terms such as exposure and dose in the ...

1986-01-01

259

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture ...

2006-01-01

260

Luminescence geochronology and evaluation of the environmental dose rate for the Neanderthal deposits at Vindija Cave (Northern Croatia)  

International Nuclear Information System (INIS)

Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at Vindija Cave, a key ...

2008-04-13

261

Historical Doses from Tritiated Water and Tritiated Hydrogen Gas Released to the Atmosphere from Lawrence Livermore National Laboratory (LLNL). Part 2. LLNL Annual Site-specific Data, 1953 - 2003  

Energy Technology Data Exchange (ETDEWEB)

It is planned to use the tritium dose model, DCART (Doses from Chronic Atmospheric Releases of Tritium), to reconstruct dose to the hypothetical maximally exposed individual from annual routine releases of tritiated water (HTO) and tritiated hydrogen gas (HT) from all Lawrence Livermore National Laboratory (LLNL) facilities and from the Sandia National (SNL) Laboratory's Tritium Research Laboratory over the last fifty years. DCART has been described in Part 1 of ''Historical Doses From Tritiated Water And Tritiated Hydrogen Gas Released To The Atmosphere from Lawrence Livermore National Laboratory (LLNL)'' (UCRL-TR-205083). This report (Part 2) summarizes information about annual routine releases of tritium from LLNL (and SNL) since 1953. Historical records were used to derive facility-specific annual data (e.g., source terms, dilution factors, ambient air ...

2005-03-07

262

Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning  

International Nuclear Information System (INIS)

This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of the patient density ...

2003-09-07

263

Cell death (apoptosis) in mouse intestine after continuous irradiation with gamma rays and with beta rays from tritiated water  

Energy Technology Data Exchange (ETDEWEB)

Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose vs incidence of ...

1989-04-01

264

The influence of inclusion spacing and microstructure on the fracture toughness of the secondary hardening steel AF1410  

Energy Technology Data Exchange (ETDEWEB)

An approach to the ductile fracture of ultra high strength steels has been evaluated. According to this approach the critical crack tip opening, delta/sub IC/, will scale with X/sub 0/(R/sub V//R/sub I/vertical bar/sub R//sub 0/. X/sub 0/ is an average inclusion spacing and (R/sub V/R/sub I/)vertical bar/sub R//sub 0/ is the void radius divided by the radius of the inclusion nucleating the void evaluated at the average inclusion size. AF1410 was selected to test this approach because it has exceptionally high fracture toughness on aging at 510/sup 0/C and because its toughness varies markedly with aging temperature. The results from this and earlier work showed a linear relationship exists between delta/sub IC/ and X/sub 0/(R/sub V//R/sub I/)vertical bar /sub R//sub 0/ for values of delta/sub IC/ ranging from about 8 ..mu..m to 60 ..mu..m. The values of (R/sub V//R/sub I/)vertical bar /sub R//sub 0/ for AF1410 aged at ...

1987-07-01

265

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or ...

2008-02-21

266

Unusual resistance to ionizing radiation of the viruses of kuru, Creutzfeldt-Jakob disease, and scrapie.  

UK PubMed Central (United Kingdom)

The titers of several preparations of kuru. Creutzfeldt-Jacob disease, and scrapie viruses were reduced by only 1/10th or less by high doses of gamma radiation of 50 kGy and by only 1/10th-1/1000th...Full Text Available

1978-12-01

267

The results of treatment of localized Ewing's sarcoma and reticulosarcoma in pediatric patients  

International Nuclear Information System (INIS)

The results of treatment of 53 cases of pediatric localized Ewing's sarcoma and bone reticulosarcoma were analized. Chemoradiotherapy is a procerdure of choice in bone marrow sarcoma treatment: while overall five-year survival was 28.4#+-#6.2%, it was as high as 64.9% in cases of combined treatment (total focal dose of at least 50 Gy+polychemotherapy). Two cases of osteo- and chondrosarcoma development in exposed bone are described.

268

Simulation of arsenic diffusion during rapid thermal annealing of silicon layers doped with low-energy high-dose ion implantation  

International Nuclear Information System (INIS)

The model of transient enhanced diffusion of ion-implanted As is formulated and the finite-difference method for numerical solution of the system of equations obtained is developed. The nonuniform distribution of point defects near the interface and more accurate description of arsenic clustering are simultaneously taken into account. Simulation of As diffusion during rapid annealing gives a reasonable agreement with the experimental data. (authors)

2005-09-01

269

Serum and salivary responses to oral tetravalent reassortant rotavirus vaccine in newborns.  

UK PubMed Central (United Kingdom)

Serum and salivary responses of 95 infants to either a standard (4 x 10(4) plaque-forming units (PFU), 47 neonates) or a high dose (4 x 10(5) PFU, 48 neonates) of tetravalent reassortant rhesus rotavirus...Full Text Available

1993-05-01

270

Radiation hazards from medical applications  

International Nuclear Information System (INIS)

An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).

1980-05-31

271

Radiation hardening of a high voltage IC technology (BCDMOS)  

International Nuclear Information System (INIS)

A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.

1990-07-16

272

Intensive combined modality therapy including low-dose TBI in high-risk Ewing's sarcoma patients  

International Nuclear Information System (INIS)

Twenty-four high-risk Ewing's sarcoma patients were treated on an intensive combined modality protocol including low-dose fractionated total body irradiaiton (TBI) and autologous bone marrow infusion (ABMI). Twenty patients (83%) achieved a complete clinical response to the primary and/or metastatic sites following induction therapy. The median disease-free interval was 18 months, and nine patients remain disease-free with a follow-up of 22 to 72 months. Local failure as a manifestation of initial relapse occurred in only three patients (15%), each having synchronous distant failure. Eight patients failed initially with only distant metastases, usually within 1-2 years following a complete clinical response. Two patterns of granulocyte recovery following consolidative therapy (including TBI and ABMI) were recognized. The time to platelet recovery was different for the groups with early and late granulocyte recovery. Patients with late recovery ...

273

Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur  

International Nuclear Information System (INIS)

Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting

2010-02-03

275

Application of dose factors for decay chains  

International Nuclear Information System (INIS)

... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor

276

On-site radiation exposure in severe reactor accidents: Scoping study  

Energy Technology Data Exchange (ETDEWEB)

The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation doses possibly received by control room personnel for ...

1990-09-01

277

Helium ion implantation in SiAlON: Characterisation of cavity structures using TEM and IBA  

International Nuclear Information System (INIS)

Highly swollen nanoporous layers produced in material surfaces by He implantation are of special interest for applications such as catalysis. Here we investigate whether nanoporous layers can be produced in the covalently bonded insulating ceramic, SiAlON. The retention of highly swollen porous structures in thinned TEM sections prepared from such hard brittle materials is particularly challenging. We have successfully prepared such sections both parallel to, and perpendicular to, the implanted surface. At intermediate doses the bubble structures are very similar to those found in metals. At high helium doses local swellings at depths around the mean projected range of the He ions (#approx#360 nm) are estimated to be well in excess of 200%. Bubble structures are stable under heating to temperatures up to 1200 deg. C. It is found that the highly cavitated layer ...

2000-05-02

278

PROBABILISTIC SAFETY ASSESSMENT OF OPERATIONAL ACCIDENTS AT THE WASTE ISOLATION PILOT PLANT  

Energy Technology Data Exchange (ETDEWEB)

This report presents a probabilistic safety assessment of radioactive doses as consequences from accident scenarios to complement the deterministic assessment presented in the Waste Isolation Pilot Plant (WIPP) Safety Analysis Report (SAR). The International Council of Radiation Protection (ICRP) recommends both assessments be conducted to ensure that ''an adequate level of safety has been achieved and that no major contributors to risk are overlooked'' (ICRP 1993). To that end, the probabilistic assessment for the WIPP accident scenarios addresses the wide range of assumptions, e.g. the range of values representing the radioactive source of an accident, that could possibly have been overlooked by the SAR. Routine releases of radionuclides from the WIPP repository to the environment during the waste emplacement operations are expected to be essentially zero. In contrast, potential accidental releases from postulated accident ...

2000-09-01

279

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

280

Machinability of magnesium alloy in ultra-precision diamond cutting  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with an experimental study of ultra-precision diamond cutting of magnesium alloy (AZ31). In order to investigate the machinability such as the cutting force and the surface integrity and understand the problems in a micro cutting, the experiments on the diamond cutting of magnesium alloy and pure aluminum with an ultra-precision turning machine has been carried out. The machinability of magnesium alloy was compared with that of pure aluminum and discussed. Consequently, both the thrust force component and the surface roughness obtained by cutting of magnesium alloy became larger than that of pure aluminum. It was also found that the inclusions or the defects in the work material caused to generate the scratches on the finished surface and influenced the integrity of mirror surface. (orig.)

2003-07-01

281

Identification of oxidation states of ultra-trace elements by radiation detection  

International Nuclear Information System (INIS)

The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.

1989-11-01

282

A numerical study of ultra-short-pulse reflectometry  

Energy Technology Data Exchange (ETDEWEB)

Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude density perturbation is assessed.

1994-05-01

283

Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines  

Energy Technology Data Exchange (ETDEWEB)

Four /sup 125/I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported /sup 75/Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).

1982-07-01

284

SIMS analysis of silicon on insulator structures formed by high-dose O/sup +/ implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis ...

1983-12-15

285

"3H thymidine an indicator of benzo(a)pyrene induced lung carcinogenesis: role of quercetin and curcumin  

International Nuclear Information System (INIS)

Full text: Lung cancer is responsible for most of the cancer related deaths and calls for new approaches to control the menace. In the present study chemopreventive efficacy of curcumin and quercetin was investigated against benzo(a)pyrene (BP) induced lung carcinogenesis. The mice were segregated into five groups which included normal control, BP treated, BP+curcumin treated, BP+quercetin treated and BP+curcumin+quercetin treated groups. The morphological and histological analyses of tumor nodules confirmed lung carcinogenesis, after 22 weeks of single i.p. injection of BP at a dose of 100 mg/Kg body weight to mice. Tumor incidence and tumor multiplicity were observed to be 88% and 1.75, respectively in the BP treated mice. A statistically significant increase in the uptake of "3H thymidine indicative of increased DNA synthesis which in turn is the marker of uncontrolled cancer cell proliferation, was observed in the lung slices of BP treated mice. Further, BP ...

286

Treatment of hematological malignancies with nonmyeloablative, HLA-haploidentical bone marrow transplantation and high dose, post-transplantation cyclophosphamide  

British Library Electronic Table of Contents (United Kingdom)

Hematopoietic stem cell transplantation provides the only potential curative option in many patients with hematological malignancies. Finding a suitably matched donor in a timely manner is often difficult. However, most patients have a partially HLA-mismatched (HLA-haploidentical) first-degree relative readily available. Historically, HLA-haploidentical bone marrow transplantation (BMT) has been considered extremely high risk due to high rates of life-threatening graft-versus-host disease (GVHD) and non-relapse mortality (NRM). Modifications of the stem cell graft, such as T-cell depletion, have resulted in poor rates of engraftment. We have recently completed a phase II clinical trial of nonmyeloablative HLA-haploidentical hematopoietic BMT followed by post-transplantation high-cyclophosp...

2011-01-01

287

Studies on natural radioactivity of some egyptian building materials  

International Nuclear Information System (INIS)

Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.

2004-02-24

288

Role of Intravenous Omeprazole in Patients with High-Risk Peptic Ulcer Bleeding After Successful Endoscopic Epinephrine Injection: A Prospective Randomized Comparative Trial  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: Epinephrine injection is the most common endoscopic therapy for peptic ulcer bleeding. Controversy exists concerning the optimal dose of proton pump inhibitors (PPI) for patients with bleeding peptic ulcers after successful endoscopic therapy. The objective of this study was to determine the optimal dose of PPI after successful endoscopic epinephrine injection in patients with bleeding peptic ulcers. METHODS: A total of 200 peptic ulcer patients with active bleeding or nonbleeding visible vessels (NBVV) who had obtained initial hemostasis with endoscopic injection of epinephrine were randomized to receive omeprazole 40 mg infusion every 6 h, omeprazole 40 mg infusion every 12 h or cimetidine (CIM) 400 mg infusion every 12 h. Outcomes were checked at 14 days after enrollment. RE...

2006-01-01

289

Radioexposure of children in cranial examinations with new-generation CT equipment  

Energy Technology Data Exchange (ETDEWEB)

Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.

1983-04-01

290

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

291

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

292

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

293

Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy  

International Nuclear Information System (INIS)

Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.

294

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

295

Ion-induced phase formation in metal-silicon systems  

International Nuclear Information System (INIS)

By using megaelectronvolt "4He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd_2Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni_2Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment. (Auth.).

296

Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator  

Energy Technology Data Exchange (ETDEWEB)

The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.

2004-12-15

297

Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator  

International Nuclear Information System (INIS)

The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.

2004-12-15

298

Exclusion, exemption and clearance in the mining and minerals industry - A review of the concepts from a South African perspective  

International Nuclear Information System (INIS)

The risks from mining and processing of ores is reviewed on a generic basis with particular reference to some of the confusions which can arise due to lack of consistency or common logic in the use of exclusion, exemption and clearance. The difference in exclusion and exemption are challenged by comparing doses received in high background radiation areas and the doses received from a mining practice. The common principle of risk to the human species is not applied consistently. The differences between IAEA recommendations and local regulatory conditions are compared, and the use of exemption levels as clearance levels is considered. A case study on management of mine tailings is presented with special focus on the use of clearance levels. In all areas of review the interpretation of regulation is subject to confusion resulting from inconsistencies which can distort free market economics. (author).

1997-05-06

299

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

300

Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).

1996-12-31

301

Coloring of cultured pearls by gamma-rays irradiation  

International Nuclear Information System (INIS)

Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for cultured blue pearls. ...

302

Chemical Analysis of Solid-State Irradiated Human Insulin  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...

2006-01-01

303

Atomic scale simulations of arsenic ion implantation and annealing in silicon  

International Nuclear Information System (INIS)

We present results of multiple-time-scale simulations of 5, 10 and 15 keV low temperature ion implantation of arsenic on silicon (100), followed by high temperature anneals. The simulations start with a molecular dynamics (MD) calculation of the primary state of damage after 10ps. The results are then coupled to a kinetic Monte Carlo (MC) simulation of bulk defect diffusion and clustering. Dose accumulation is achieved considering that at low temperatures the damage produced in the lattice is stable. After the desired dose is accumulated, the system is annealed at 800 degrees C for several seconds. The results provide information on the evolution for the damage microstructure over macroscopic length and time scales and affords direct comparison to experimental results. We discuss the database of inputs to the MC model and how it affects the diffusion process.

2004-12-15

304

Asymmetry effect of particle size distribution on content uniformity and over-potency risk in low-dose solid drugs  

British Library Electronic Table of Contents (United Kingdom)

Most active pharmaceutical ingredients (API) exhibit particle size distributions with some degrees of asymmetry deviating from log-normality. A new log-skew-normal (L-S-N) distribution model is proposed for a systematic comparison of the asymmetry effect on content uniformity. The new model originated from the S-N model used by Azzalini gives a close approximation to real API particle size distribution. Monte-Carlo method was employed to simulate the dosage potency distribution. A high risk of over potency is uncovered when either the dose is low or API particle size distribution is positively skewed. This is due to the formation of pseudo heavy tail in potency distribution that decays slower than exponentially. Nomographs of API particle size versus dosage strength were constructed with a...

2010-01-01

305

A trial of probabilistic simulation for reference case in the second progress report on research and development for the geological disposal of HLW in Japan  

International Nuclear Information System (INIS)

This paper presents a trial of probabilistic simulation for performance assessment of high-level waste (HLW) disposal using the Monte Carlo method. Based on the Reference Case conceptual model in H12, a new integrated simulation system which allowed us to rapidly evaluate the effect of data uncertainty was developed. The doses to hypothetical exposure group were compared with the results of H12 that were performed by using a point-wise approach, in terms of maximum total dose. This study showed that H12 results were consistent with results of probabilistic simulation and also showed that transmissivity had a strong influence for the uncertainty of the system performance in all simulation time. (author)

2000-12-01

306

A routine chemical dosimetric system using the modified ceric sulphate dosimeter  

International Nuclear Information System (INIS)

The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.

1994-10-01

307

Surface Roughness of Stainless Steel Bender Mirrors for FocusingSoft X-rays  

Energy Technology Data Exchange (ETDEWEB)

We have used polished stainless steel as a mirror substrate to provide focusing of soft x-rays in grazing incidence reflection. The substrate is bent to an elliptical shape with large curvature and high stresses in the substrate require a strong elastic material. Conventional material choices of silicon or of glass will not withstand the stress required. The use of steel allows the substrates to be polished and installed flat, using screws in tapped holes. The ultra-high-vacuum bender mechanism is motorized and computer controlled. These mirrors are used to deliver focused beams of soft x-rays onto the surface of a sample for experiments at the Advanced Light Source (ALS). They provide an illumination field that can be as small as the mirror demagnification allows, for localized study, and can be enlarged, under computer control,for survey measurements over areas of the surface up to several millimeters. The critical issue of the quality of the ...

2005-10-11

308

Simulation of dopant diffusion and activation during flash lamp annealing  

International Nuclear Information System (INIS)

A set of advanced models implemented into the simulator Sentaurus Process was applied to simulate ultra shallow junction formation by flash lamp annealing (FLA). The full path transient enhanced diffusion model includes equations for small interstitial clusters (I_2, I_3, I_4), #left brace#3 1 1#right brace# defects and dislocation loops. A dopant-point defect clustering model is used for dopant activation simulation. Several cluster types are considered: B_2, B_2I, B_2I_2, B_3I, B_3I_2, B_3I_3 for boron and As_2, As_2V, As_3, As_3V, As_4, As_4V for arsenic. Different point defect and dopant-point defect pair charge states are taken into account to obtain accurate results in the high doping level region. The flux expressions in the three-phase segregation model include a dependence on the doping level and point defect supersaturation. The FLA process was performed at various peak temperatures in a Mattson Millios"T"M fRTP"T"M system. The ...

2008-12-05

309

New processing technique for forming flexible A-15 superconducting tapes with extremely high critical current densities  

Energy Technology Data Exchange (ETDEWEB)

A-15 compounds are extremely brittle and difficult to process for practical applications. A novel processing technique was developed to greatly improve the mechanical and superconducting properties of A-15 alloys. The new processing technique can be described as follows: (1) to select compounds that can form the A-15 phase (the selected A-15 compounds in this research were Ti3Nb6Mo3Si4 and Nb99.5-(x + y)AlxSiyB0.5 alloys); (2) to rapidly solidify them into the amorphous state; (3) to anneal the quenched amorphous products into ultra fine-grained single A-15 phase. The extreme grain refinement greatly improved the flexibility and the critical current density of the alloys. The melt spinning technique was used to rapidly solidify Ti3Nb6Mo3Si4 and Nb99.5-(x + y)AlxSiyB0.5 alloys. Ti3Nb6Mo3Si4 alloys were relatively easily formed into the amorphous state. Nb3Al alloys required the addition of glass forming elements Si and B. It was found that, without boron, the ...

1986-01-01

310

New processing technique for forming flexible A-15 superconducting tapes with extremely high critical current densities  

International Nuclear Information System (INIS)

A-15 compounds are extremely brittle and difficult to process for practical applications. A novel processing technique was developed to greatly improve the mechanical and superconducting properties of A-15 alloys. The new processing technique can be described as follows: (1) to select compounds that can form the A-15 phase (the selected A-15 compounds in this research were Ti3Nb6Mo3Si4 and Nb99.5-(x + y)AlxSiyB0.5 alloys); (2) to rapidly solidify them into the amorphous state; (3) to anneal the quenched amorphous products into ultra fine-grained single A-15 phase. The extreme grain refinement greatly improved the flexibility and the critical current density of the alloys. The melt spinning technique was used to rapidly solidify Ti3Nb6Mo3Si4 and Nb99.5-(x + y)AlxSiyB0.5 alloys. Ti3Nb6Mo3Si4 alloys were relatively easily formed into the amorphous state. Nb3Al alloys required the addition of glass forming elements Si and B. It was found that, without boron, the ...

311

Electrochemical and surface analytical studies of the interaction of nitrogen with key alloying elements in stainless steels  

Energy Technology Data Exchange (ETDEWEB)

Surface analytical studies of high nitrogen austenitic stainless steels exposed to deaerated 0.1M HCl have revealed that nitrogen alloying additions influence the composition of salt layers and the passive film/alloy interface. In this study the authors employ electrochemical techniques and variable angle X-ray Photoelectron Spectroscopy (XPS) to examine the passive films formed on a series of austenitic stainless steels, Fe18Cr8Ni, Fe18Cr8Ni0.2N, Fe20Cr20Ni, Fe20Cr20Ni6Mo and Fe20Cr20Ni6Mo0.2N, in acidic chloride aqueous solution. In addition, several other model alloys, Fe19Cr, Fe19Cr9Ni, Fe19Cr2.5Mo, and Fe19Cr9Ni2.5Mo, were examined before and after electrochemical surface nitriding, a technique proven to have an effect analogous to N alloying. It was shown that nitrogen, nickel and molybdenum additions independently and in certain combinations stimulate selective dissolution of iron, resulting in a significant enrichment of chromium beneath the passive film. ...

1995-12-01

312

Electrochemical and surface analytical studies of the interaction of nitrogen with key alloying elements in stainless steels  

International Nuclear Information System (INIS)

Surface analytical studies of high nitrogen austenitic stainless steels exposed to deaerated 0.1M HCl have revealed that nitrogen alloying additions influence the composition of salt layers and the passive film/alloy interface. In this study the authors employ electrochemical techniques and variable angle X-ray Photoelectron Spectroscopy (XPS) to examine the passive films formed on a series of austenitic stainless steels, Fe18Cr8Ni, Fe18Cr8Ni0.2N, Fe20Cr20Ni, Fe20Cr20Ni6Mo and Fe20Cr20Ni6Mo0.2N, in acidic chloride aqueous solution. In addition, several other model alloys, Fe19Cr, Fe19Cr9Ni, Fe19Cr2.5Mo, and Fe19Cr9Ni2.5Mo, were examined before and after electrochemical surface nitriding, a technique proven to have an effect analogous to N alloying. It was shown that nitrogen, nickel and molybdenum additions independently and in certain combinations stimulate selective dissolution of iron, resulting in a significant enrichment of chromium beneath the passive film. ...

1995-03-26

313

Demonstrating leadership inside and out : green building project trains employees, educates clients  

Energy Technology Data Exchange (ETDEWEB)

This article described a full-scale green renovation project undertaken by a construction management firm in Newton, Massachusetts. Chapman Construction and Design began renovating its own office building in late 2007 and completed it in September 2008. The firm set out to achieve LEED Platinum certification from the United States Green Building Council. The project involved energy saving modifications to its mechanical systems; replacing plumbing fixtures with high efficiency alternatives to reduce water consumption by at least 40 per cent; installing skylights and additional windows to allow more natural light into the interior space; salvaging doors, lighting, metal studs and masonry whenever possible; and using sustainable products such as recyclable carpets, tiles and low-VOC paint. The main feature of the renovation was a new 47 kW (DC) photovoltaic (PV) solar power array installed on the rooftop. The PV array includes 208 panels and a SunPower SPR-225 system ...

2009-01-15

314

DEEP DESULFURIZATION OF DIESEL FUELS BY A NOVEL INTEGRATED APPROACH  

Energy Technology Data Exchange (ETDEWEB)

Due to the increasingly stricter regulations for deep reduction of fuel sulfur content, development of new deep desulfurization processes for liquid transport fuels has become one of the major challenges to the refining industry and to the production of hydrocarbon fuels for fuel cell applications. The sulfur compounds in the current transport fuels corresponding to the S level of 350-500 ppm account for only about 0.12-0.25 wt % of the fuel. The conventional hydrotreating approaches will need to increase catalyst bed volume at high-temperature and high-pressure conditions for treating 100 % of the whole fuel in order to convert the fuel mass of less than 0.25 wt %. In the present study, we are exploring a novel adsorption process for desulfurization at low temperatures, which can effectively reduce the sulfur content in gasoline, jet fuel and diesel fuel at low investment and operating cost to meet the needs for ...

2001-09-01

315

Chemistry of transuranium elements and compounds  

International Nuclear Information System (INIS)

Studies are made in this program to enhance our understanding of the role of 5f electrons in chemical bonding. Most of our studies on the macroscopic scale emphasize certain isotopes available from the National Transplutonium Production Program centered at HFIR/TRU -namely, _9_6"2"4"8Cm, _9_7"2"4"9Bk, _9_8"2"4"9Cf, _9_9"2"5"3Es, and _9_9"2"5"4Es. Particular classes of compounds, such as hydrides, chalcogenides, and pnictides are often selected for study on the basis of their utility in bringing out significant chemical differences between the lanthanides and the actinides. High temperature/high pressure experiments on actinide metals and compounds reveal characteristics about the degree of 5f electron localization as a function of atomic number in the series. Magnetic properties of metals and compounds are investigated using ultra-sensitive methods and hydration numbers of ions in solution are investigated by neutron ...

1986-05-01

316

A wirelessly powered and controlled device for optical neural control of freely-behaving animals.  

Science.gov (United States)

Optogenetics, the ability to use light to activate and silence specific neuron types within neural networks in vivo and in vitro, is revolutionizing neuroscientists' capacity to understand how defined neural circuit elements contribute to normal and pathological brain functions. Typically, awake behaving experiments are conducted by inserting an optical fiber into the brain, tethered to a remote laser, or by utilizing an implanted light-emitting diode (LED), tethered to a remote power source. A fully wireless system would enable chronic or longitudinal experiments where long duration tethering is impractical, and would also support high-throughput experimentation. However, the high power requirements of light sources (LEDs, lasers), especially in the context of the extended illumination periods often desired in experiments, precludes battery-powered approaches from being widely applicable. We have developed a headborne device weighing 2 g ...

2011-06-23

317

Using of beam spoilers in linear accelerators with photons of 10 MV  

International Nuclear Information System (INIS)

This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm"2, 8 x 8 cm"2 and 10 x 10 cm"2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically ...

1998-11-22

318

Role of accelerator mass spectrometry in biological dosimetry  

International Nuclear Information System (INIS)

Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying ...

1992-04-05

319

Radiation factors specifying safety in reactor compartments handling in the process of decommissioning nuclear-powered submarines  

International Nuclear Information System (INIS)

The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...

1996-03-10

320

Radiation decontamination of dry food ingredients and processing aids  

International Nuclear Information System (INIS)

Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be irradiated in its final packaging. Irradiation ...

321

Quantitative assessment of cancer risk from exposure to diesel engine emissions  

Energy Technology Data Exchange (ETDEWEB)

Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were developed using either a time-to-tumor or a ...

1993-02-01

322

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-12-01

323

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-01-01

324

Effects of ionizing radiation on properties of monolayer and multilayer flexible food packaging materials  

International Nuclear Information System (INIS)

Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon irradiation. These products may affect organoleptic properties and thus ...

1999-05-01

325

Effects of epidermal growth factor on bone formation and resorption in vivo  

Energy Technology Data Exchange (ETDEWEB)

The effects of mouse epidermal growth factor (EGF) on bone formation and resorption were examined in male mice. EGF administration (2-200 ng.g-1.day-1 ip for 7 days) induced a dose-dependent rise in plasma EGF levels that remained within physiological range. Histomorphometric analysis of caudal vertebrae showed that EGF (20 and 200 ng.g-1.day-1) reduced the endosteal matrix and mineral appositional rates after 5 days of treatment as measured by double (3H)proline labeling and double tetracycline labeling, respectively. This effect was transitory and was not observed after 7 days of EGF administration. EGF administered for 7 days induced a dose-dependent increase in the periosteal osteoblastic and tetracycline double-labeled surfaces. At high dosage (200 ng.g-1.day-1) EGF administration increased the osteoclastic surface and the number of acid phosphatase-stained osteoclasts, although plasma calcium remained normal. The ...

1990-02-01

326

Effects of carbon monoxide on myocardial ischemia  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. A significant dose-response relationship was found for the individual differences in the time to ST end point and ...

1991-02-01

327

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major ...

1986-01-01

328

Comparison of intrinsic and extrinsic tracer methods for estimating calcium bioavailability to rats from dairy foods  

International Nuclear Information System (INIS)

Dairy products doubly labeled with 45Ca and 47Ca were used to evaluate an extrinsic labeling procedure for calcium bioavailability determination. Nonfat milk, yogurt, and fresh cheese curd were prepared from caprine milk that was intrinsically labeled with 45Ca. The products were then labeled extrinsically with 47Ca and administered to rats by gavage. The 47Ca to 45Ca ratio in bone and teeth averaged about 1.00 with either milk, yogurt, or CaCl2, but the ratio was about 1.04 when dosed with cheese curd. Ca absorption, determined by whole-body counting of 47Ca, was lower (P less than 0.05) in cheese curd (59%) than in either milk (69%), yogurt (72%), or CaCl2 (72%). Expressed as percent of dose, the absorption of 47Ca was highly correlated with bone 47Ca (r = 0.973) and with bone 45Ca (r = 0.946). Correlation between tibia 47Ca and tibia 45Ca was r = 0.923. For the dairy products tested, our results indicated that extrinsic ...

329

A new plateau in the dose-survival-time response of the golden hamster (Mesocricetus auratus) from whole body irradiation  

International Nuclear Information System (INIS)

The survival time of golden hamsters (Mesocricetus auratus) after whole-body "6"0Co-#gamma#-irradiation in the range of 600 to 200 000 rad was investigated. The two plateaus of the dose-survival curve which correspond to bone marrow and gastrointestinal death are similar to those of other species such as mice, rats and mongolian gerbils. A new plateau occurring 40-57 hours after doses of 30 000-60 000 rad, where there is a little reduction in survival time, has been found. It is in addition to the well recognized central nervous system (CNS) syndrome. This plateau is observed only in golden hamsters, presumably because of their relatively high resistance to CNS syndrome. Experiments involving partial body irradiation of the animals indicate that the target is in the cephalic one-third of abdomen. The new segment may well indicate a new type of acute somatic radiation injury different from the well known bone marrow, ...

1981-01-01

330

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. ...

2006-11-13

331

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical ...

2010-07-07

332

Mesozoic Era of relativistic heavy ion physics and beyond.  

Science.gov (United States)

In order to understand how matter 15 billion years ago in the form of quarks, gluons and leptons at a temperature of 2 (times) 10(sup 12) (degrees)K evolved to become today's Universe, the goal of relativistic and ultra-relativistic heavy ion physics is t...

1994-01-01

333

Breaking the 1000-gene barrier for Mimivirus using ultra-deep genome and transcriptome sequencing  

UK PubMed Central (United Kingdom)

BackgroundMimivirus, a giant dsDNA virus infecting Acanthamoeba, is the prototype of the mimiviridae family, the latest addition to the family of the nucleocytoplasmic...Full Text Available

334

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 ...

2006-01-01

335

Effect of hydrostatic pressure on photoluminescence spectra from structures with Si nanocrystals fabricated in SiO_2 matrix  

International Nuclear Information System (INIS)

The effect of hydrostatic pressure applied at high temperature on photoluminescence of Si-implanted SiO_2 films was studied. A 'blue'-shift of PL spectrum from the SiO_2 films implanted with Si"+ ions to total dose of 1.2x10"1"7 cm"-"2 with increase in hydrostatic pressure was observed. For the films implanted with Si"+ions to a total dose of 4.8x10"1"6 cm"-"2 high temperature annealing under high hydrostatic pressure (12 kbar) causes a 'red'-shift of photoluminescence spectrum. The 'red' photoluminescence bands are attributed to Si nanocrystals while the 'blue' ones are related to Si nanocrystals of reduced size or chains of silicon atoms or Si-Si defects. A decrease in size of Si nanocluster occurs in result of the pressure-induced decrease in the diffusion of silicon atoms. (author)

2001-09-23

336

The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations  

International Nuclear Information System (INIS)

Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose re-buildup, which occurs ...

2002-07-01

337

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers  

International Nuclear Information System (INIS)

Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for ...

2001-11-01

338

CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging  

Energy Technology Data Exchange (ETDEWEB)

To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P = 0.02). Across all regimens, stool tagging quality was ...

2008-01-15

339

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This dosimeter can give a rough estimation of the ...

1983-06-01

340

Updated estimates of the proportion of childhood leukaemia incidence in Great Britain that may be caused by natural background ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to update the previous results. Using the newer dosimetry we ...

2009-12-01

341

Gamma radiation effects at color, antioxidant capacity and fatty acid profile in peanut (Arachis hypogaea L.)  

International Nuclear Information System (INIS)

Irradiation is efficient at extinction fungi contamination in peanuts. Peanuts have high biologic value protein, minerals, vitamin E, complex B, and high concentration of lipids. The objective of this research is to evaluate the gamma irradiation effect on color, total phenolic, antioxidant activity, and fatty acid profile in peanuts (Arachis hypogaea L.). Cultivars IAC-Tatu ST and IAC-Runner 886 were submitted to gamma radiation with doses of 5.0; 7.5; 10.0, and 15.0 kGy and storage at room temperature. There was no significant difference in the color of IAC-Tatu ST. However, significant difference was found in the luminosity and Chroma in IAC-Runner 886. Total fenolics differed from the control with 33.27 mg.g-1 and treatment dose of 10.0 kGy with 58.60 mg.g-1 in IAC-Tatu ST. This parameter not had significant difference in IAC-Runner 886 and the control with 51.59 mg.g-1. The antioxidant activity did ...

2011-01-01

342

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-06-01

343

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-01-01

344

Evaluation of Beta-Absorbed Fractions in a Mouse Model for 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177Lu Radionuclides  

Energy Technology Data Exchange (ETDEWEB)

Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and ...

2005-08-01

345

Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled ...

2006-11-15

346

Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation  

International Nuclear Information System (INIS)

Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled ...

2006-11-01

347

Migration of strontium in the food chain of plants, animals and man - problems and risks  

International Nuclear Information System (INIS)

The aims of investigation were to follow the Sr transport in the food chain from the flora to the fauna and humans, and its dependence on the geological origin og the plant site, industrial emissions, the age and site of plants, the part of plant used for nutrition and the strontium content in the drinking water, to determine the Sr intake of humans with the help of the duplicate method, and to estimate the apparent absorption rate and balance of strontium depending on of the form of diet (mixed or ovolactovegetarian), sex, season, age, region (geological origin of the living space) and method of intake measurement (duplicate or basket method). Strontium, an ultra trace element widespread in the earth's crust, is not essential and only mildly toxic for plants, animals and man according to current knowledge. The biological essentiality of Sr has not been investigated yet. Amoeba species living in sea water use Sr for the formation of their skeleton instead of Ca. ...

2008-10-15

348

Effect of decrease of molybdenum radiation hardening at high energy proton irradiation  

International Nuclear Information System (INIS)

By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.

1990-05-22

349

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63  

International Nuclear Information System (INIS)

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical ...

2003-06-01

350

Materials research and beam line operation utilizing NSLS. Progress report  

Energy Technology Data Exchange (ETDEWEB)

MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year the full 242 operational days were utilized. Beam line test and evaluation consumed 21 days with eight MATRIX groups combining to use 170 days. General user demand for use of the beam line continues to be strong and three groups were provided 51 operating days. Research production has been growing as NSLS and the beam line become a more stable type of operation. For 1990 the MATRIX group published nine articles. To ...

1991-10-01

351

Energy efficient soil disinfestation by microwaves  

Energy Technology Data Exchange (ETDEWEB)

A major obstacle prohibiting the use of microwaves for soil disinfection and disinfestation is the large amount of energy required to obtain sufficient results. The present work presents an experimental study of the effect of initial soil temperature and soil moisture on energy consumption by application of microwaves for soil disinfection. All experiments were carried out by using a microwave generator of a nominal power output of 900 W. The ultra-high-frequency field (2450{+-}2 MHZ) was produced by a magnetron tube and channelled through a metal waveguide. The output opening of the waveguide was placed directly on the soil surface. It was found that a soil with 15% moisture content (w.b.) and an initial temperature of 20degC requires energy to be heated at a depth of 10 cm up to 61degC which is 3.2 times more than the energy required to heat the soil up to 5 cm depth at the same initial temperature. In general, the conversion of electric energy to useful ...

2000-02-01

352

Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.  

Science.gov (United States)

In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 (held in Coeur d'Alene, Idaho) to use ...

2009-02-19

353

Experimental and theoretical studies of nuclear generation of ozone and its photolysis into singlet delta oxygen  

International Nuclear Information System (INIS)

A series of measurements of O_3 yield in nuclear induced O_2 and O_2-SF_6 discharges created by bombardment with energetic particles from the "1"0B(n,#alpha#)"7Li reaction are reported. Continuous irradiation at dose ratios of 10"1"5-10"1"7 eV.cm"-"3.s"-"1 and pulsed irradiation (approx.10 ms FWHM) at a peak dose rate of approx.10"2"0 eV.cm"-"3.s"-"1 were conducted. At the lower dose rates, SF_6 addition generally increased the ozone yield, which at the high dose rates, SF_6 addition decreased the observed ozone concentration. A numerical model was developed and applied to experimental conditions. The steady-state ozone concentration was found to be limited by the reaction O_3"- + O_3 #-># 2O_2 + O_2"-. A simplified analytical model of steady-state conditions was used to predict model sensitivity to various parameters. In addition to dose rate effects, ...

354

Transient enhanced diffusion of Sb and B due to MeV silicon implants  

Energy Technology Data Exchange (ETDEWEB)

We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si{sup +} ion implants at very high doses ({approx}10{sup 16}cm{sup {minus}2}). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation ({approx}700 at 740{degree}C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of {l_brace}311{r_brace} defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial ...

1997-06-01

355

Transient enhanced diffusion of Sb and B due to MeV silicon implants  

International Nuclear Information System (INIS)

We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si"+ ion implants at very high doses (#approx#10"1"6cm"-"2). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation (#approx#700 at 740 degree C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of #left brace#311#right brace# defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial supersaturation is ...

356

The effect of irradiation on packaging materials  

International Nuclear Information System (INIS)

Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation doses used for the control of contaminants in cosmetic products are quite ...

357

Mechanism for transient-enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

High-dose ion implantation followed by solid-phase-epitaxial (SPE) growth is now a well-established technique for the production of supersaturated silicon alloys. However, these alloys also contain a high supersaturation of silicon interstitials, which give rise to transient, greatly enhanced dopant diffusion with subsequent heating. In this contribution, the authors present a study of a series of Si-Sb alloys of various concentrations which were made by Sb implantation under various conditions to deduce the origin of the observed transient diffusion. A multiple implant scheme was employed to produce samples with an approximately uniform dopant concentration from 40 to 150 nm in depth, but with the amorphous layer extending to a depth of 380 nm. By scaling the implant doses, alloys with different concentrations in the uniform region were produced, allowing an accurate measure of diffusion coefficients as a function of ...

1985-03-01

358

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science ...

2008-05-01

359

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

360

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

361

The role of lesions of DNA in senescence of seeds of Lupinus polyphyllus L. induced by chronic low-intensity irradiation  

International Nuclear Information System (INIS)

A nonlinear relationship between the time of accelerated aging of Lupine seeds and the indices of its survival as well as the single-strand DNA amount in cells from these seeds is established. The character of this relationship is essentially altered in chronically irradiated lupine seeds from the Chernobyl NPP exclusion zone and seems more complicated. The possible role of repair systems in these effects is discussed. The fact that chronic irradiation in low doses can modify the course of senescence in lupine seeds reflects its high biological efficiency comparing with acute irradiation.

2000-08-01

362

Superconductivity of neutron irradiated Mo_3Os  

International Nuclear Information System (INIS)

The effect of high energy neutron irradiation (E > 1 MeV) on the superconducting transition temperature, Tsub(c), of the A-15 compound Mo_3Os is reported. Tsub(c) was found to decrease with increasing neutron dose, but at a rate considerably less than observed in other A-15 compounds composed of non-transition metals. The results lend support to the idea that the effect of ordering on Tsub(c) is smaller for A-15 compounds composed only of transition metals than those composed of transition and non-transition metals. (author).

363

Smart Acquisition EELS  

Energy Technology Data Exchange (ETDEWEB)

Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.

2010-07-01

364

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

365

Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.

366

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

367

Neutron irradiation effects in austenitic alloys  

International Nuclear Information System (INIS)

The post (neutron) -irradiation high-temperature tensile and creep-rupture properties, deformation and fracture characteristics of austenitic alloys, particularly solution annealed Type 316 steel, are surveyed and correlated with the damage structures developed as a function of irradiation temperature (and dose). The mechanisms proposed to explain the irradiation-induced changes in properties and behaviour are summarised. The factors responsible for the observed differences in the post-irradiation and 'in-reactor' creep-rupture properties and behaviour of an austenitic steel are discussed in terms of the helium gas and stress driven growth of small intergranular bubbles and the atom plating associated with their growth and coalescence. (author).

1980-03-01

368

Inactivation of aflatoxin B1 by using the synergistic effect of hydrogen peroxide and gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Inactivation of aflatoxin B1 was studied by using gamma radiation and hydrogen peroxide. A 100-krad dose of gamma radiation was sufficient to inactivate 50 micrograms of aflatoxin B1 in the presence of 5% hydrogen peroxide, and 400 krad was required for total degradation of 100 micrograms of aflatoxin in the same system. Degradation of aflatoxin B1 was confirmed by high-pressure liquid chromatographic and thin-layer chromatographic analysis. Ames microsomal mutagenicity test showed loss of aflatoxin activity. This method of detoxification also reduces the toxin levels effectively in artificially contaminated groundnuts.

1989-02-01

369

Employment of /sup 203/Pb isotoic solution without a carrier for erythrocyte tracing  

Energy Technology Data Exchange (ETDEWEB)

Possibilities of applying the Pb/sup 203/ isotonic solution without a carrier as a label of blood erythrocytes, are found. There is a number of advantages in the Pb/sup 203/ isotonic solution without a carrier, such as a high label efficiency (above 95%), a short half-life (52 hours), and a low radiation dose. These factors prove to be favourable as compared with Cr/sup 51/ widely used for these purposes. Besides, of all preparations used up to now to treat erythrocytes and to scan the spleen, it is only in the case of Pb/sup 203/ isotonic solution without a carrier that no weight amounts of chemical substances do not enter the organism.

1981-08-01

370

Effects of gamma irradiation on the sperm transmission and oviposition response in Helicoverpa armigera (L. NOCTUIDAE)  

International Nuclear Information System (INIS)

Transmissions of sperm by unirradiated and irradiated cotton bollworm, Helicoverpa armigera, were studied by live dissection of females immediately after the initiation of mating. In cotton bollworm the sperm transfer was rather a complex process. In fact unirradiated males failed to transfer sperm in about 19% of their matings. When irradiated with 250 Gy and 400 Gy, aberrations of sperm transmission were about 21% and 50% respectively. The failure of spermatophore 'cap' location was an important reason of sperm transmission aberrations. When females mated to high-dose-irradiated males, their oviposition response appeared abnormal

2002-02-01

371

Computerized tomography in the diagnosis and follow up in three observations of primitive suprasellar germinoma  

International Nuclear Information System (INIS)

Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.

1986-01-01

372

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

374

Disposal of De-ionizer Vessels Highly Contaminated with 14Carbon at SRS  

International Nuclear Information System (INIS)

At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high 14C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the 14C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous 14C. This investigation implemented a more ...

2008-01-01

375

High dose rate /sup 60/Co remote afterloading irradiation in cancer of the cervix in Haiti, 1977-1984  

Energy Technology Data Exchange (ETDEWEB)

From 1977 through 1984, 293 previously untreated patients with biopsy proven carcinoma of the uterine cervix were treated by whole pelvis irradiation and high intensity 60Co remote afterloading (RAL) intrauterine tandem techniques in Haiti. The treatment results were analyzed retrospectively to evaluate the therapeutic results and prognostic factors of a strict protocol involving 40 Gy to the whole pelvis (2 Gy/day, 5 days/week). In addition, on the 5th day of the 3rd week, the first outpatient 60Co remote afterloading intracavitary insertion, delivering 7.5 Gy to point A with each insertion, repeated 3 times by a week separation for a total of 4 times. The total TDF for external beam plus RAL was 158 and 175 for early and late effects respectively. One hundred-four patients were evaluable after 1 year or more follow-up, with a median of 26.5 months. No evidence of disease (NED) by Stage at 1 year was: Stage I of 100% (3/3), Stage II of 82% (9/11), Stage III of 80% ...

1988-06-01

376

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

377

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

378

The radioecological risk of decommissioning of nuclear submarines. Possible accidents and normal conditions  

International Nuclear Information System (INIS)

In the report the results of the estimations of radiological risk of various stages of decommissioning of nuclear submarines are presented. At occurrence on nuclear submarine the heavy failure, relating to the class hypotetical volume of acting of radionuclides in atmosphere can reach 1.6E(15) Bq. Results of estimations probable doses on an axis of a trace of a radioactive loop show, that at distribution of radionuclides during atmospheric carry to 'agreed' settlement (500-1000 m) the maximum doses on its territory can make: about 6.0E(-3) Sv (for the whole body); 3.0E(-3) Gy for the leather (basal layer); 6.3E(-2) Gy for the lungs (acute exposure) and up to 1.8 Gy for the thyroid gland. Hypotetical failure for the estimation of the greatest possible radioecological consequences for hydrobiocenosis is considering, connected with single discharge of liquid radioactive waste (LRW) in water area. At navigating failure of the tanker with LRW in ...

2000-05-01

379

The influence of different chemical elements in the hardening/embrittlement of RPV steels  

International Nuclear Information System (INIS)

The hardening and embrittlement of reactor pressure vessel (RPV) steels is of great concern in the actual nuclear power plant life assessment. This embrittlement is caused by irradiation-induced damage, like vacancies, interstitials, solutes and their clusters. The current procedure to estimate material properties for the irradiated pressure vessels is based on Charpy-V tests of identical material located at the inner shell of the reactor. But the reason for the embrittlement of the materials is not yet totally known. The real nature of the irradiation damage should thus be examined as well as its evolution in time. Fe-Cu binary alloys are often used to mimic the behaviour of such steels. Their study allows. Identifying some of the defects responsible of the hardening, especially when compared to pure iron or C-micro-alloyed iron. More recently the influence of manganese and nickel in low-Cu RPV steels has become a significant topic. Thus in contrast with the existing models in the ...

2007-06-04

380

The helical tomotherapy thread effect  

International Nuclear Information System (INIS)

Inherent to helical tomotherapy is a dose variation pattern that manifests as a 'ripple' (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of 1/n where n is an integer. A convolution-superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near p=0.86(1/n). The 0.86 factor is empirical and caused by a beam junctioning of the off-axis dose profiles ...

2005-05-01

381

Radiation hardening technologies facing total dose, S.E.U. and S.E.L. in spatial environment  

International Nuclear Information System (INIS)

Space particles act on semiconductor devices by creating charges (electrons, holes) in the silicon and the silicon dioxide, and by creating displacement damage. These primary phenomena alter the electrical parameters of MOS and bipolar devices (threshold voltage V_t, mobility #mu#, conductivity #sigma#, current gain #beta#). The dose rate is not important in space (a few rad (Si)/h) but as the durations of space expeditions are on average from seven to twelve years, the total dose is an aggravating factor in the behaviour of the electrical parameters and also in device operation. The total dose effect from the beginning of charge creation (ionization) to the parameter shifts is reviewed. One can note that this effect is permanent because there will almost always be charge creation in space. Another important phenomenon is called the Single Event Upset (S.E.U.) and caused by the heavy ions and the protons which come from the ...

382

Medical consequences of radiation accidents  

International Nuclear Information System (INIS)

Since 1945, more than 1.8 x 10"2"1 Bq of artificial radionuclides have been released into the atmosphere. Approximately 2.04 x 10"1"8B, i.e. approx. 0.11%, are the result of accidents at nuclear industrial facilities. This percentage is causing increased interest among researchers. This is due to the fact that in the wake of accidental release radionuclides become distributed unevenly across the Earth's surface, and the associated exposures, fluctuating from background level to several grays, an induce both stochastic and deterministic effects in the irradiated population. A comparative analysis of the medical consequences of the twentieth century's most serious nuclear events, namely the authorized dumping of high level radioactive waste into the river Techa in 1950, the explosion of a storage tank containing long lived radioactive waste in the Southern Urals in 1957, the fire at Sellafield in 1957 and the accident at the Chernobyl nuclear power plant in 1986, has ...

1995-10-01

383

Inherited sterility progeny gamma irradiated male Spiny Bollworm Earias Insulana Boisd  

International Nuclear Information System (INIS)

The present work studies the fecundity, egg batching and mating of normal females of Earias Insulana Boisd. crossed with males irradiated as 24 h adult moths with two doses (80 and 100 Gy.) of gamma radiation. The male progeny were out bred or inbred with untreated individuals for two successive generations F_1and F_2 and their progeny was observed for any inherited deleterious effects on reproduction. The female fecundity and egg hatch were significantly reduced among P1,F1 and F2 generations by increasing the dosages applied to P_1 males as compared with the untreated control. The percentage of mating of P_1 females was significantly reduced at the two doses as compared to the untreated control. The average number of spermatophores per mated female was reduced among P_1,F_1 and F_2 generations when parental males were irradiated with 100 Gy. The larval and pupal mortality a,o mg F_1, F_2 and F_3 generations was high and ...

2003-01-01

384

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all ...

2003-12-01

385

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were ...

2003-12-01

386

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of {sup 40}K, {sup 238}U and {sup 232}Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of {sup 40}K, {sup 238}U and {sup 232}Th in local prepared diets ranged between 60 and 494 Bq kg{sup -1}, between BDL and 48 Bq kg{sup -1} and between BDL and 17 Bq kg{sup -1}, respectively. The internal effective dose to individuals from the consumption of ...

2007-04-15

387

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

International Nuclear Information System (INIS)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of "4"0K, "2"3"8U and "2"3"2Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of "4"0K, "2"3"8U and "2"3"2Th in local prepared diets ranged between 60 and 494 Bq kg"-"1, between BDL and 48 Bq kg"-"1 and between BDL and 17 Bq kg"-"1, respectively. The internal effective dose to individuals from the consumption of the food types was estimated on ...

2007-04-01

388

Dose dependent transfer of [sup 203]lead to milk and tissue uptake in suckling offspring studied in rats and mice  

Energy Technology Data Exchange (ETDEWEB)

The dose-dependent transfer of [sup 203]Pb to milk and uptake in suckling rats and mice during a three-day nursing period was studied. On day 14 of lactation, the dams were administered a single intravenous dose of lead, labelled with [sup 203]Pb, in four or five doses from 0.0005 to 2.0 mg Pb/kg b.wt. There was a linear relationship between Pb levels in plasma and milk of both species. The Pb milk: plasma ratios at 24 hr after administration were 119 and 89 in mice and rats, respectively. At 72 hr the Pb milk: plasma ratio had decreased to 72 in mice and 35 in rats. The tissue levels of lead in the suckling rats and mice were also linearly correlated with lead concentration in milk at 72 hr, showing that milk could be used as an indicator of lead exposure to the suckling offspring. It is concluded that lead is transported into rat and mouse milk to a very high extent and the excretion into milk is more ...

1993-09-01

389

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, ...

2007-09-21

390

Depuration of shellfish by irradiation: Final technical report, October 1, 1987--March 31, 1989  

International Nuclear Information System (INIS)

Studies by the University of Lowell Radiation Laboratory and the US National Marine Fisheries Service N.E. Laboratory in Gloucester, MA on softshelled clams (Mya arenaria) demonstrated the effectiveness of low to medium doses of Cobalt 60 source gamma irradiation in the inactivation of Escherichia coli, Salmonella typhimurium, Staphylococcus aureus and Streptococcus faecalis. Post-irradiation survival and organoleptic studies when extended to hardshelled clams (Mercinaria mercenaria) and American oysters (Crassostrea virginica) showed no significant decline in consumer qualities or 6 day post irradiation survival in oysters at doses of up to 3.0 kGy. The capacities of the American oyster to sustain relatively high doses of gamma irradiation were demonstrated by 6 day post-exposure survivorship values of greater than 90% for samples receiving 3.0, 5.0 and 7.0 kGy. Initial studies of inactivation of Polio ...

391

Comparison of bone cancer risks in beagle dogs for inhaled plutonium-238 dioxide, inhaled strontium-90 chloride, and injected strontium-90  

Energy Technology Data Exchange (ETDEWEB)

There is a continuing need to understand dose-response relationships for ionizing radiation in order to protect the health of the public and nuclear workers from undue exposures. However, relatively few human populations have been exposed to doses of radiation high enough to cause observable, long-term health effects from which to derive dose-response relationships. This is particularly true for internally deposited radionuclides, although much effort has been devoted to epidemiological studies of the few types of exposures available, including lung cancers in uranium miners form the inhalation of the radioactive decay products of Ra, liver cancers in patients injected with Thorotrast X-ray contrast medium containing Th, bone cancers in radium dial painters who ingested Ra, and bone cancers in patients who received therapeutic doses of Ra. These four types of exposures to internally ...

1995-12-01

392

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

393

Half-period optical pulse generation using a free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Recently there has been growth, in interest in non-equilibrium interaction of half-period long optical pulses with matter. To date the optical pulses have been produced by chopping out a half-period long segment from a longer pulse using a semiconductor switch driven by a femtosecond laser. In this paper we present new methods for producing tunable ultra-short optical pulses as short as half an optical period using a free-electron laser driven by electron bunches with a duration a fraction of an optical period. Two different methods relying on the production of coherent spontaneous emission will be described. In the first method we show that when a train of ultra-short optical pulses as short as one half period. We present calculations which show that the small signal gain is unimportant in the early stages of radiation build up in the cavity when the startup process is dominated by coherent spontaneous emission. To support our proposed method ...

1995-12-31

394

Correlation between tensile property and micro-hardness in reduced activation ferritic/martensitic steel irradiated at 573 K  

International Nuclear Information System (INIS)

Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials used in this study were F82H IEA heat and F82H heat treatment variants. Neutron ...

2007-12-10

395

A study on the development of hypo-stoichiometric Zr-based hydrogen storage alloys with ultra-high capacity for anode material of Ni/MH secondary battery  

Energy Technology Data Exchange (ETDEWEB)

Some hypo-stoichiometric Zr-based Laves phase alloys were prepared and studied from a viewpoint of discharge capacity for electrochemical application. After careful alloy design of ZrMn{sub 2}-based hydrogen storage alloys through changing their stoichiometry while substituting or adding some alloying elements, the Zr(Mn{sub 0.2}V{sub 0.2}Ni{sub 0.6}){sub 1.8} alloy reveals relatively good properties with regard to hydrogen storage capacity, hydrogen equilibrium pressure and electrochemical discharge capacity. In order to improve the discharge capacity and rate-capability, Zr is partially replaced by Ti. The discharge capacity of Zr{sub 1-x}Ti{sub x}(Mn{sub 0.2}V{sub 0.2}Ni{sub 0.6}){sub 1.8} (x=0.0, 0.2, 0.3, 0.4, 0.6) alloy electrodes at 30 C reaches a maximum value and decreases as the Ti fraction increases. In view of electrochemical and thermodynamic characteristics, the occurrence of a maximal phenomenon of the electrochemical discharge capacity of the alloy is attributed to a ...

2000-08-10

396

VARIATION IN SIZE, DEVELOPMENT, AND HOOK NUMBER AMONG THE ONCOSPHERES OF NORMAL AND IRRADIATED HYMENOLEPIS DIMINUTA  

Science.gov (United States)

Oncospheres produced by a nonirradiated worm and oncospheres produced by a worm that had been subjected to high gamma radiation (successive generations of cysticercoids were irradiated with 15,000 r until a cumulative dose of 120,000 r was obtained) were compared. Radiation had no effect on the sizes of the embryos, the shell, and the median hooks. Radiation may have resulted in certain large, hookless embryos that did not occur in the normal worm. Two anomalies, reduced hook number and failure of growth, were more frequent in the normal than in the irradiated worm. This result, although surprising, can be explained by the high selection pressure operating under the experimental conditions. (auth)

1962-01-01

397

Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines  

International Nuclear Information System (INIS)

Four "1"2"5I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported "7"5Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).

398

Radiosensitization of human lung fibroblasts by chemicals that decrease ATP levels  

International Nuclear Information System (INIS)

Radiosensitization by lactate, pyruvate, nalidixic acid and novobiocin was studied in exponentially growing SH-18L human lung fibroblasts. All the chemicals had a slight radiosensitizing effect at a low concentration and a definite effect at a higher one. Decreases in the D_0 and/or Dq values were present in each dose survival curve. Fibroblasts incubated with the low concentration of each chemical for 24 hrs after X irradiation showed no reduction in intracellular ATP content, whereas, the higher concentration produced a significant decrease. These observations suggest that the decrease in the ATP content may be involved in the radiosensitization of human fibroblasts at high concentrations of these chemicals. In contrast, radiosensitization at a low concentration is not explained by a relationship to ATP content. Different mechanisms may be involved in radiosensitization at low and high concentrations of these chemicals. ...

399

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

400

Propagation of Surface Ripples on Pyrochlore Single Crystals Induced by Ion Beam Bombardment  

Energy Technology Data Exchange (ETDEWEB)

The morphological evolution of ripples formed on the surface of Cd2Nb2O7 pyrochlore single crystals by focused ion beam (FIB) bombardment was investigated using in situ electron microscopy. At high ion fluences and off-normal bombardment angles, faceted surface ripples with a terrace-like structure were observed. The ripple propagation direction was oriented along the projected ion beam direction at incident angles ranging from 35 to 65 following high-dose ion bombardment. One side of the terrace was found to be perpendicular to the incident ion beam direction, while the other side was parallel to the ion beam. The terrace propagation velocity and direction were determined and interpreted on the basis of this asymmetric structure. A model based on the propagation of a shock wave that effectively self-selects a stable slope, was developed in order to explain the observed faceted ripple formation.

2009-08-01

401

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

402

New [{sup 99m}Tc]-cytectrene amine compounds as specific brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Lipophilic tertiary amines attached to cylcopentadienyl technetium-99m tricarbonyl (cytectrene) have been prepared with high radiochemical yield and purity. Biodistribution studies in mice showed that [{sup 99m}Tc]-cytectrenes, containing in their structure an N-methylpiperidine, were accumulated in the brain up to 2.8% of injected dose with high brain-to-blood ratios at 15 min p.i. They therefore indicate some potential as brain imaging agents. It has to be pointed out that the N-methylpiperidine ester showed similar biological behaviour as the keto derivatives. This indicates that the conversion to polar metabolite(s) via hydrolysis of the ester group - as described for [{sup 99m}Tc]-ECD -is not essential for brain retention. (Author).

1995-02-01

403

New ["9"9"mTc]-cytectrene amine compounds as specific brain imaging agents  

International Nuclear Information System (INIS)

Lipophilic tertiary amines attached to cylcopentadienyl technetium-99m tricarbonyl (cytectrene) have been prepared with high radiochemical yield and purity. Biodistribution studies in mice showed that ["9"9"mTc]-cytectrenes, containing in their structure an N-methylpiperidine, were accumulated in the brain up to 2.8% of injected dose with high brain-to-blood ratios at 15 min p.i. They therefore indicate some potential as brain imaging agents. It has to be pointed out that the N-methylpiperidine ester showed similar biological behaviour as the keto derivatives. This indicates that the conversion to polar metabolite(s) via hydrolysis of the ester group - as described for ["9"9"mTc]-ECD -is not essential for brain retention. (Author).

404

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

405

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

Energy Technology Data Exchange (ETDEWEB)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of {approximately}2E13cm{sup {minus}2}. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

1995-12-31

406

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

International Nuclear Information System (INIS)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of #approx#2E13cm"-"2. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

407

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...

2008-11-19

408

Study of the mineral variation of two varieties of pigeonpea (Cajanus cajan (L.) Millsp) submitted to different doses of fertilizers by the neutron activation analysis; Acompanhamento da variacao mineral de duas cultivares de guandu (Cajanus cajan (L.) Millsp) submetidas a diferentes doses de fertilizantes, pelo metodo de analise por ativacao com neutrons  

Energy Technology Data Exchange (ETDEWEB)

Instrumental neutron activation analysis (INAA) followed by gamma-ray spectrometry was used to determine the concentrations of As, Ca, Co, Cr, Cu, Eu, Fe, K, La, Mg, Mn, Mo, Na, Pr, Sb, Se, Th, U, V and Z, in 82 leaf samples belonging to two cultivars of pigeonpea (Cajanus cajan (L.) Millsp). Pigeonpea, an easy cultivation legume species, probably originated from Africa and adapted to brazilian conditions, is a very promising and unconventional source of food, mainly to the grain production intended for human feeding, and that even can be used in flour products. It is an excellent proteic supplement for ruminants, due to its large potential of forage production and its high nutritive value, or in addition it can be used in the recuperation of exhausting soils either by means of its utilization as green manure or by taking free Nitrogen from the atmosphere to produce nitrates which can be utilized by the plants. However, in spite of the several possibilities and ...

2001-07-01

409

Natural background radiation induces cytogenetic radioadaptive response more effectively than occupational exposure in human peripheral blood lymphocytes  

Science.gov (United States)

Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 ...

2003-01-01

410

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD) (follicle-stimulating hormone (FSH), 10 +/- 15 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 ..beta..-estradiol (E/sub 2/) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developd persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 109 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E/sub ...

1981-12-01

411

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD (follicle-stimulating hormone (FSH), 10 +/- 5 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 beta-estradiol (E2) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developed persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 108 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E2 (19 +/- 8 ...

1981-12-01

412

Effective use of optimized, high-dose (50 kGy) gamma irradiation for pathogen inactivation of human bone allografts.  

Science.gov (United States)

The safety of tissue allografts has come under increased scrutiny due to recent reports of allograft-associated bacterial and viral infections in tissue recipients. We report that 50 kGy of gamma irradiation, nearly three times the dose currently used, is an effective pathogen inactivation method when used under optimized conditions that minimize damage to the tissue. Cancellous bone dowels treated with a radioprotectant solution and 50 kGy of optimized irradiation had an ultimate compressive strength and modulus of elasticity equal to conventionally irradiated (18 kGy) and non-irradiated control bone grafts. We subjected bone dowels treated with this pathogen inactivation method to an in vitro cytotoxicity test using three different mammalian cell lines and concluded that the treated grafts were not cytotoxic. The log reduction of nine pathogens spiked into radioprotectant-treated bone irradiated to 50 kGy was also tested. We achieved 4.9 logs of inactivation of a ...

2005-05-01

413

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and exposure ...

1985-01-01

414

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

Energy Technology Data Exchange (ETDEWEB)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, ...

2007-11-15

415

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

International Nuclear Information System (INIS)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. ...

2007-11-01

416

Investigation on boron transient enhanced diffusion induced by the advanced P{sup +}/N ultra-shallow junction fabrication processes  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P{sup +}/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B{sup +} and BF{sub 2}{sup +} ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF{sub 3} as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit ...

2005-08-01

417

Investigation on boron transient enhanced diffusion induced by the advanced P"+/N ultra-shallow junction fabrication processes  

International Nuclear Information System (INIS)

In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P"+/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B"+ and BF_2"+ ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF_3 as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit coming from PLAD ...

2005-08-01

418

H_2 emission arises outside photodissociation regions in ultra-luminous infrared galaxies  

CERN Document Server

Ultra-luminous infrared galaxies are among the most luminous objects in the local universe and are thought to be powered by intense star formation. It has been shown that in these objects the rotational spectral lines of molecular hydrogen observed at mid-infrared wavelengths are not affected by dust obscuration, leaving unresolved the source of excitation of this emission. Here I report an analysis of archival Spitzer Space Telescope data on ultra-luminous infrared galaxies and demonstrate that star formation regions are buried inside optically thick clouds of gas and dust, so that dust obscuration affects star-formation indicators but not molecular hydrogen. I thereby establish that the emission of H_2 is not co-spatial with the buried starburst activity and originates outside the obscured regions. This is rather surprising in light of the standard view that H_2 emission is directly associated with star-formation activity. Instead, I propose ...

2010-01-01

419

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

420

Mechanical Engineering and Design of the LHC Phase II Collimators  

CERN Document Server

Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are ...

2010-01-01

421

Test of electron beam technology on Savannah River Laboratory low-activity aqueous waste for destruction of benzene, benzene derivatives, and bacteria  

Energy Technology Data Exchange (ETDEWEB)

High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of irradiation on those populations was also ...

1993-08-01

422

Some thoughts on stem cells and carcinogenesis. The thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this review is to consider the hypothesis that cancer frequently originates from stem cells. Using the spleen transplantation assay where stem cells were transplanted in the spleen of mice lethally irradiated by ionizing radiation, the author undertook a study aimed at defining the risk of radiogenic cancer per susceptible cells with use of rat radiogenic mammary and thyroid cancers because of the high incidences of these cancers in a-bomb survivors. Measured were the number of cancer-susceptible cells initially present in the tissue, the number of such cells that survived at a given dose and the number of cancers that developed per surviving cell. Thyroid cell differentiation and proliferation in rats transplanted with thyroid cells were enhanced by thyroidectomy and low iodine diet. Further, the relationship between the low LET radiation dose and thyroid clonogen survival was also investigated. Data showed ...

2000-07-01

423

Shellfish depuration by gamma irradiation: Final report for the period October 1, 1985-September 30, 1986  

International Nuclear Information System (INIS)

Irradiation of live bivalve molluscs is a promising new technique to reduce the public health threats of viral and bacterial pathogens in the consumption of raw shellfish. In studies conducted within the past year, live hardshelled clams and oysters were innoculated with Simian Rotavirus SA-11, Poliovirus I, and Hepatitis-A virus and treated with gamma ray ionizing radiation from University of Lowell/DOE 800,000 Curie "6"0Co source over a dose range of 0.5--10 kiloGray (50--1000 kilorad) to determine the effectiveness of the process in eliminating viral activity and thus easing the potential viral health threats associated with uncooked bivalves. Two viral strains, SA-11 and Poliovirus I, were employed as models to perfect laboratory technique and to estimate the most appropriate range of dose exposures necessary for optimal inactivation of the infectious pathogen, Hepatitis A. Post-irradiation survivorship of the oysters and quahogs was ...

424

Recovery of {sup 15}N-urea in soil-plant system of tanzania grass pasture; Recuperacao de {sup 15}N-ureia no sistema solo-planta de pastagem de capim-Tanzania  

Energy Technology Data Exchange (ETDEWEB)

The economic attractiveness and negative environmental impact of nitrogen (N) fertilization in pastures depend on the N use efficiency in the soil-plant system. However, the recovery of urea-{sup 15}N by Panicum maximum cv. Tanzania pastures, one of the most widely used forage species in intensified pastoral systems, is still unknown. This experiment was conducted in a randomized complete block design with four treatments (0, 40, 80 and 120 kg ha-1 of N-urea) and three replications, to determine the recovery of {sup 15}N urea by Tanzania grass. Forage production, total N content and N yield were not affected by fertilization (p > 0.05), reflecting the high losses of applied N under the experimental conditions. The recovery of {sup 15}N urea (% of applied N) in forage and roots was not affected by fertilization levels (p > 0.05), but decreased exponentially in the soil and soil-plant system (p < 0.05) with increasing urea ...

2009-01-15

425

Recovery of Tsub(c) by annealing of irradiated A-15 compounds  

International Nuclear Information System (INIS)

Data on the recovery of Tsub(c) for several neutron irradiated A-15 compounds are presented. A model for the mechanism of recovery is suggested and has been applied to isothermal annealing data at 550"0C on a sample of Nb_3Ge and to isochronal annealing (200"0C-900"0C) data on V_3Si, Nb_3Ge and Nb_3Sn subjected to varying doses of fast neutrons and on Nb_3Al of various compositions subjected to the same dose. The recovery is assumed to take place by vacancy assisted reordering and occurs in several stages. The major low temperature stage is attributed to irradiation induced vacancies, while at high temperatures there are depleted and recovery is ascribed to the motion of thermal equilibrium vacancies. Activation energies deduced for these processes, approximately 1 eV for vacancy motion and approximately 1-2 eV for vacancy formation, are consistent with what is known about diffusion in the A-15 structure. (Auth.).

426

Recovery of "1"5N-urea in soil-plant system of tanzania grass pasture  

International Nuclear Information System (INIS)

The economic attractiveness and negative environmental impact of nitrogen (N) fertilization in pastures depend on the N use efficiency in the soil-plant system. However, the recovery of urea-"1"5N by Panicum maximum cv. Tanzania pastures, one of the most widely used forage species in intensified pastoral systems, is still unknown. This experiment was conducted in a randomized complete block design with four treatments (0, 40, 80 and 120 kg ha-1 of N-urea) and three replications, to determine the recovery of "1"5N urea by Tanzania grass. Forage production, total N content and N yield were not affected by fertilization (p > 0.05), reflecting the high losses of applied N under the experimental conditions. The recovery of "1"5N urea (% of applied N) in forage and roots was not affected by fertilization levels (p > 0.05), but decreased exponentially in the soil and soil-plant system (p < 0.05) with increasing urea doses. The amount of "1"5N ...

427

Radon measurements in the Catalagzi Thermal Power Plant, Turkey  

Energy Technology Data Exchange (ETDEWEB)

The Catalagzi Thermal Power Plant (CTPP) is located at nearly 13 km North-east of Zonguldak city, which is located at the West Black Sea coast in Turkey. The middling products with high ash content of bituminous coals are used in this plant. Seasonal radon concentration measurements have been carried out by using CR-39 plastic track detectors in and around the CTPP. The annual average radon concentration has been found to vary from a minimum of 39.8 {+-} 28.9 Bq m{sup -3}) in the ash area to a maximum of about to 75.0 {+-} 15.7 Bq m{sup -3} in the service building of the power plant. The annual average radon concentration in the dwellings of the thermal power plant colony of the plant is 71.0 {+-} 33.4 Bq m{sup -3}. The effective dose has been found to vary from 0.38 to 0.71 mSv y{sup -1} with a mean value of 0.56 mSv y{sup -1}, which is lower than the effective dose values 3-10 mSv given as the range of action levels ...

2008-01-15

428

Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania  

Energy Technology Data Exchange (ETDEWEB)

In the Harghita volcanic range (Romania) there are many occurrences of dry CO{sub 2} emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m{sup 3} while within the gas pools' values between 3210 and 32 781 Bq/m{sup 3} have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major ...

2008-12-15

429

Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania  

International Nuclear Information System (INIS)

In the Harghita volcanic range (Romania) there are many occurrences of dry CO2 emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m3 while within the gas pools' values between 3210 and 32 781 Bq/m3 have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major seasonal variations of the radon ...

2008-12-01

430

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient tools for these ...

2009-06-15

431

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in ...

2006-11-13

432

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been possible by the newer insights gained in the mechanism of biological effects of ...

433

Radiation inactivation target size of rat adipocyte glucose transporters in the plasma membrane and intracellular pools  

Energy Technology Data Exchange (ETDEWEB)

The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior to and after insulin treatment, ...

1987-06-15

434

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

Energy Technology Data Exchange (ETDEWEB)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic manipulation as much as ...

1990-05-01

435

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

International Nuclear Information System (INIS)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic manipulation as much as ...

1990-01-01

436

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of radiotherapy of ...

1983-01-01

437

Local composition analysis of SiC microstructures formed by ion projection in silicon using energy filtered TEM in combination with FIB specimen preparation  

International Nuclear Information System (INIS)

Buried silicon carbide (SiC) microstructures with lateral dimensions in the #mu#m range were formed by high-dose projection of 1.5 MeV C"2"+ ions in Si(100) at different doses and temperatures and subsequent annealing for 10 h at 1250 deg. C. Sections of individual SiC microstructures were prepared for cross-sectional transmission electron microscopy (TEM) analysis using a focused ion beam (FIB). Besides the possibility to select an individual microstructure, the FIB technique has the advantage of producing specimen foils of uniform thickness. Therefore, it was possible to map the carbon concentration of microstructures by energy filtered TEM (EFTEM) using the C_K absorption edge without the need of any sample thickness correction. Local overstoichiometric (>50%) carbon concentrations are shown to be correlated to the formation of an amorphous phase in the SiC and to significant swelling visible at the Si wafer surface 2 #mu#m above.

2003-09-15

438

Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study  

International Nuclear Information System (INIS)

Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral ...

2010-01-01

439

Identifying primary stressors impacting macroinvertebrates in the Salinas River (California, USA): Relative effects of pesticides and suspended particles  

International Nuclear Information System (INIS)

Laboratory dose-response experiments with organophosphate and pyrethroid pesticides, and dose-response experiments with increasing particle loads were used to determine which of these stressors were likely responsible for the toxicity and macroinvertebrate impacts previously observed in the Salinas River. Experiments were conducted with the amphipod Hyalella azteca, the baetid mayfly Procloeon sp., and the midge Chironomus dilutus (Shobanov, formerly Chironomus tentans). The results indicate the primary stressor impacting H. azteca was pesticides, including chlorpyrifos and permethrin. The mayfly Procloeon sp. was sensitive to chlorpyrifos and permethrin within the range of concentrations of these pesticides measured in the river. Chironomus dilutus were sensitive to chlorpyrifos within the ranges of concentrations measured in the river. None of the species tested were affected by turbidity as high as 1000 NTUs. The current ...

2006-06-01

440

IRIS Simplified LERF Model  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS). One of the key aspects of the IRIS design is its safety-by-designTM philosophy and within this framework the PRA is being used as an integral part of the design process. The most ambitious risk-related goal for IRIS is to reduce the Emergency Planning Zone (EPZ) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. As a first step, a model has been developed to provide a first order approximation of the Large Early Release Frequency (LERF) as a surrogate predictor of the off-site doses. A key-aspect of the LERF model development is the characterization of the possible paths of release. Four main categories have been historically ...

2004-10-06

441

Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis  

International Nuclear Information System (INIS)

The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including ...

2003-06-01

442

Effect of gamma irradiation on tensile properties of low molecular weight polyethylene samples  

International Nuclear Information System (INIS)

Three high density polyethylene (PE) samples of different origins, with weight average molar masses ranging from 38 to 63 kg mol"-"1 and displaying a semi-ductile behavior with strain at break ?_R values of the order of 100-140%, were gamma irradiated under nitrogen for doses up to 33.3 kGy. Steric exclusion chromatography and rheometry allowed to quantify the crosslink density X. This later reached values ranging from 4.6 to 9.0x10"-"3 mol kg"-"1, i.e. situated below the gelation point. Differential calorimetry, density measurement and small angle X-rays scattering showed the absence of significant changes in the crystalline morphology, especially lamellar dimensions. Tensile testing revealed an unexpected trend towards brittle regime of fracture while yield stress increases significantly at low doses. It appeared that branching disfavors cavitation during yielding, but this effect is not favorable to ductility.

2011-08-01

443

Theoretical Standard Model Rates of Proton to Neutron Conversions Near Metallic Hydride Surfaces  

CERN Document Server

The process of radiation induced electron capture by protons or deuterons producing new ultra low momentum neutrons and neutrinos may be theoretically described within the standard field theoretical model of electroweak interactions. For protons or deuterons in the neighborhoods of surfaces of condensed matter metallic hydride cathodes, such conversions are determined in part by the collective plasma modes of the participating charged particles, e.g. electrons and protons. The radiation energy required for such low energy nuclear reactions may be supplied by the applied voltage required to push a strong charged current across a metallic hydride surface employed as a cathode within a chemical cell. The electroweak rates of the resulting ultra low momentum neutron production are computed from these considerations.

2006-01-01

444

Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint.

2007-11-15

445

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

446

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of ...

2008-08-01

447

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

1981-06-01

448

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

449

Absorbed dose and dose reduction in mammography  

International Nuclear Information System (INIS)

First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).

1986-01-01

450

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum ...

2010-11-24

451

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

452

Evaluation of transient dose in conveyor type low dose irradiator  

International Nuclear Information System (INIS)

In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)

2003-03-05

453

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

454

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

455

Stochastic risk estimate for barium radiological examinations in Malaga (Spain)  

International Nuclear Information System (INIS)

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...

2000-01-01

456

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

457

Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.  

UK PubMed Central (United Kingdom)

Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available

1982-03-01

458

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

459

Effects of small doses of ionizing radiation on human health  

Energy Technology Data Exchange (ETDEWEB)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-12-01

460

Effects of small doses of ionizing radiation on human health  

International Nuclear Information System (INIS)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-01-01

461

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

462

A two-stage sequential linear programming approach to IMRT dose optimization  

UK PubMed Central (United Kingdom)

The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available

2010-02-07

463

Long-term IL-2 therapy after transplantation of T cell depleted stem cells from alternative donors in children  

British Library Electronic Table of Contents (United Kingdom)

The aim of this pilot study was to evaluate the feasibility of long-term subcutaneous application of low-dose IL-2 in children with malignancies at very high risk of relapse who underwent highly T cell and B cell depleted HLA-identical (MUD) or full haplotype mismatched related hematopoetic stem cell transplantation. We studied 11 patients with acute leukemias/myelodysplastic syndrome and juvenile myelomonocytic leukemia (active disease and/or second stem cell transplantation, n = 8; >=CR 2, n = 2) and relapsed or progressive Ewings sarcoma (n = 2) who received prophylactic IL-2 treatment for a high probability of disease recurrence after allo-HSCT. Toxicities from IL-2 were transient fever, fatigue and local inflammation. In one patient GvHD grade III with no clear association to IL-2 adm...

2011-01-01

464

Boron-enhanced diffusion of boron from ultralow-energy ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050&hthinsp;{degree}C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1{percent} and 10{percent}, though it appears to be closer to 1{percent} for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3{times}10{sup 14} and 1{times}10{sup 15} cm{sup {minus}2}. It is proposed that the excess interstitials responsible for BED are produced during ...

1999-04-01

465

Boron-enhanced diffusion of boron from ultralow-energy ion implantation  

International Nuclear Information System (INIS)

We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050 ampersand hthinsp;degree C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1% and 10%, though it appears to be closer to 1% for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3x10"1"4 and 1x10"1"5 cm"-"2. It is proposed that the excess interstitials responsible for BED are produced during the formation of a silicon boride phase in the ...

1999-04-01

466

HDR and MDR intracavitary treatment for carcinoma of the uterine cervix. A prospective randomized study  

Energy Technology Data Exchange (ETDEWEB)

Aim: Treatment of carcinoma of the uterine cervix by remote afterloading brachytherapy has been accompanied with new isotopes having dose rates different from the classical low-dose rate (LDR) radium source. The dose rate conversion factor from LDR to high-dose rate (HDR) found to be around 0.54 in most studies. As regards medium-dose rate (MDR) brachytherapie, the published data are very few and the experience is still short. In this study the experience of Osaka University Hospital with micro-HDR-Selectron and Selectron-MDR, as a preliminary report of the clinical trial, is presented. Results: The 3-year survival and loco-regional control rates for both modalities were nearly equivalent (62% and 67% for HDR and 68% and 74% for MDR)(totally 45 patients). The cumulative rectal and bladder complication rates were the same in both groups (29% at 3 years), with only 1 patient ...

1997-03-01

467

Spectral sensitivity study of dose distributions for a commercial convolution/superposition algorithm  

International Nuclear Information System (INIS)

The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p ...

2004-09-21

468

Simulation for position determination of distal and proximal edges for SOBP irradiation in hadron therapy by using the maximum likelihood estimation method  

Energy Technology Data Exchange (ETDEWEB)

In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the ...

2005-12-21

469

Role of radiation therapy in the management of nonmetastatic Ewing's sarcoma of bone. Report of the intergroup Ewing's sarcoma study  

International Nuclear Information System (INIS)

The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in ...

470

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, shipment and storage. Radiation treatment of food may be classified broadly into two categories: 1. Processes requiring ...

471

Induction and use of sex linked lethal mutations in the pink bollworm  

International Nuclear Information System (INIS)

The sterile insect release technique can often be improved by removal of females before release. Rearing efficiencies can also be increased if removal of the females occurs at early developmental stages. In order to begin to develop genetic sexing strains for the pink bollworm, Pectinophora gossypiella (Saunders), it was necessary to determine the best dosage of radiation for induction of viable sex linked recessive lethal mutations and to see if stocks containing induced sex linked lethals could be maintained in culture. Sex linked recessive lethal mutations can be detected by distorted sex ratios in the progeny of treated adults. However, in the pink bollworm, highly distorted sex ratios are common even in the absence of induced mutations. Therefore, a visible sex linked trait, purple eye, was used as a marker for the untreated X-chromosomes in crosses. Thus, the presence of a recessive sex linked lethal mutation induced by the radiation treatment may be detected ...

1987-11-16

472

Comparative tissue distribution and excretion of orally administered ["3H]diacetoxyscirpenol (anguidine) in rats and mice  

International Nuclear Information System (INIS)

A quantitative comparison of tissue distribution and excretion of an orally administered sublethal dose of [3H]diacetoxyscirpenol (anguidine) was made in rats and mice 90 min, 24 hr, and 7 days after treatment. Total recoveries of 95-100% were obtained. Approximately 90% of the dose was excreted in urine and feces during the first 24 hr with a feces:urine ratio of about 1:4.5 in both species. Carcass and tissue radioactivity dropped rapidly during the first 24 hr but remained relatively constant at low, but detectable, levels over the course of the experiment. Few substantive interspecies differences were noted in tissue distribution. At 90 min the highest percentage of dose was in tissues involved in sequestering diacetoxyscirpenol because of high body water/lipid content or the absorption, metabolism, or excretion of the toxin. The rank order of these tissues was generally stable over the course of ...

473

Biological Effects after Prenatal Irradiation  

International Nuclear Information System (INIS)

A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental retardation after exposures during the 8th to 15th week post conception in ...

474

Biokinetic and dosimetric studies of {sup 188}Re-hyaluronic acid: a new radiopharmaceutical for treatment of hepatocellular carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and aspartate aminotranferase ...

2009-08-15

475

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

476

The implementation of SOMO (SOlution MOdeller) in the UltraScan analytical ultracentrifugation data analysis suite: enhanced capabilities allow the reliable hydrodynamic modeling of virtually any kind of biomacromolecule  

UK PubMed Central (United Kingdom)

The interpretation of solution hydrodynamic data in terms of macromolecular structural parameters is not a straightforward task. Over the years, several approaches have been developed to cope...Full Text Available

2010-02-01

477

SLAROM-UF: Ultra fine group cell calculation code for fast reactor  

International Nuclear Information System (INIS)

A cell calculation code SLAROM-UF was developed to improve calculation accuracy of effective cross sections for various fast reactor types. SLAROM-UF has a capability to calculate effective cross sections in ultra fine groups of about 100,000 below 50keV and in fine groups above the energy (maximum 900 groups). Resonance interaction among the fuel, the coolant, and the structure materials can be treated accurately even in a heterogeneous cell structure. Temperature can be set up freely in a cell by the ultra fine group calculation. Improvement in nuclear characteristics was observed in the analysis of JUPITER critical experiment, as 0.1% for criticality, 4% for sodium void reactivity, several % for radial reaction rate distribution, when SLAROM-UF was used instead of the typical cell calculation code. The effect of the ultra fine group calculation is remarkable in the non-leakage term of sodium void reactivity, and that of ...

478

Nanophotonic components utilizing channel plasmon polaritons  

Science.gov (United States)

Channel plasmon polaritons (CPPs) propagating along the bottom of subwavelength grooves cut into a metal surface were recently shown to exhibit strong confinement combined with low propagation loss, a feature that makes this guiding configuration very promising for the realisation of ultra-compact photonic components. Here, the results of our investigations of CPP guiding by V-grooves cut into gold are presented, demonstrating efficient large-angle bending and splitting of radiation as well as waveguide-ring resonators and Bragg grating filters.

2008-08-01

479

In situ spectroscopic and corrosion studies of ultra-thin gradient plasma polymer layers on zinc  

International Nuclear Information System (INIS)

By means of an audio frequency plasma polymerisation ultra-thin gradient plasma polymer layers were deposited on zinc and zinc-coated iron. The aim was to generate an interfacial polymeric layer which bonds to an oxidised metal as well as to a subsequently applied organic coating and acts as an interfacial barrier layer for ions and water. Surface modifications were done in an in situ plasma cell with infrared reflection absorption spectroscopy (IRRAS). The zinc surface was first activated by an oxygen plasma to provide a freshly oxidised and contamination free oxide surface. The intermediate stages of the surface reactions could be revealed. Carbon dioxide molecules as oxidation products adsorbed on the growing zinc oxide and were desorbed at a later stage. An organosilicon plasma polymer was deposited directly on top of the oxide layer from a hexamethyldisilane (HMDS) plasma. Afterwards a cyclohexene (CHEX)/hexamethyldisilane co-plasma polymer was deposited. The ...

2003-07-15

480

Determination of heavy metals in welders' working environment using nuclear analytical methods  

International Nuclear Information System (INIS)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).

1985-01-01

481

Determination of heavy metals in welders' working environment using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.

1985-01-03

482

Determination of [sup 99]Tc in sea water at ultra low levels  

Energy Technology Data Exchange (ETDEWEB)

A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].

1994-01-20

483

A Theory of Laser Induced Nuclear Reaction in Single Atoms  

International Nuclear Information System (INIS)

An 'electron-bridge' mechanism of nuclear reaction in an atom or ion by ultra-intense laser fields is presented. A preliminary estimate of the intensity dependence of the rate of disintegration reaction of deuteron nucleus in deuterium atom is made for 800 nm laser fields. For intensities below 5x1021 W/cm2, the rate of disintegration by the 'electron-bridge' mechanism is found to be small, but it rises sharply and becomes large already for ?1022 W/cm2.

2010-02-02

484

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...

2002-03-01

485

Effect of propylbenzilylcholine mustard on contraction and radioligand binding parameters of muscarinic receptors in guinea pig ileum  

Energy Technology Data Exchange (ETDEWEB)

The receptor occupancy-biological effect relationship for muscarinic receptors in guinea pig ileal smooth muscle has been studied by comparison of radioligand binding and contractile response. Muscarinic receptors in homogenates of ileal smooth muscle were labeled with (/sub 3/H)-1-Quinuclidinyl benzilate. Treatment with propylbenzilylcholine mustard (PrBCM), to inactivate irreversibly muscarinic receptors, caused a large dose dependent rightward shift of the dose-response curve to three agonistic furtrethonium derivatives with a concomitant decrease in maximal response. Using those data, the fraction of receptors remaining unoccupied (q-values) and true affinity constants (-log K/sub A/-values) were calculated. Exposure to 20 or 60 nM PrBCM for 15 minutes resulted in a 39% and a 61% reduction in specific (/sup 3/H)-1-Quinuclidinyl benzilate binding sites respectively to be compared with a 62% and a 85% decrease expected from calculated ...

1987-10-26

486

Development of methods of forecasting properties of polymer packaging materials which do not cause any changes in medicinal preparations during sterilization  

International Nuclear Information System (INIS)

The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physico-mechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl acrylate (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5 - 20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the ...

1974-12-09

487

Development of methods for forecasting properties of polymer packaging materials which do not cause any change in medicinal preparation during their sterilization  

International Nuclear Information System (INIS)

The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physicomechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5-20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the ...

1975-01-01

488

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...

2009-09-01

489

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

490

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

491

Polymers and paper as packaging materials of irradiated food  

International Nuclear Information System (INIS)

Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)

2000-03-01

492

Long-Term Follow-Up of Patients with Breast Cancer Transplanted with Autologous Ex Vivo Expanded Peripheral Blood Progenitor Cells  

British Library Electronic Table of Contents (United Kingdom)

Ex vivo expanded peripheral blood progenitor cells (PBPC) have been shown to provide rapid neutrophil engraftment, and in some patients, to eliminate neutropenia after transplantation to support high-dose chemotherapy. However, the effect of expansion culture on stem cell content and potential loss of stem cells caused by induction of differentiation remains a concern. We have transplanted 21 patients with breast cancer with expanded autologous PBPC, with 11 patients receiving expanded PBPC as their sole hematopoietic cell source. In these studies, the CD34+ cells were selected and cultured for 10 days in defined media containing 100 ng/mL each of recombinant human stem cell factor (rhSCF), recombinant human granulocyte colony stimulating factor (rhG-CSF), and recombinant human megakaryocy...

2006-01-01

493

Effect of the GnRH antagonist, acyline, on canine testicular characteristics.  

Science.gov (United States)

The primary objective was to assess the effects and clinical safety of a single high-dose of the third generation GnRH antagonist, acyline, on testicular characteristics in male dogs. Seven dogs were followed up weekly for six, 2-week periods (-2, -1, 1, 2, 3 and 4). At the end of the second period, they were given acyline (330 microg/kg sc). Responses to treatment varied among individual animals. Testicular consistency and scrotal diameter were slightly diminished (P>0.05) in Periods 1, 2, and 3. Libido and erection decreased during Periods 1 and 2 (Pdecreased semen quality with no adverse effects. PMID:17586037

2007-06-21

494

DNA repair: As influenced by age, nutrition, and exposure to toxic substances  

International Nuclear Information System (INIS)

In evaluating the risk associated with low levels of exposure to toxicants, it is clear that DNA repair, one of the main defenses against agent damage, is not a constant. It can be modified by age, time of day, and physiological state. Nutrition, especially caloric restriction (CR), can modify almost every step in the process of protecting genomic integrity. And history of exposure can modify DNA repair. Thus, the conditions of exposure are almost as important to toxicity as the exposure itself, even at the level of DNA repair. Extrapolation from high to low dose, to be consistent with what is known, should be less a mathematical exercise than an exercise in toxicological judgement, which puts the exposure in proper perspective. This appears to be true at almost every level in the process including a response with a toxic stimulus, even those thought to be very basic, such as DNA repair.

495

Cryo-irradiation as a terminal method for the sterilization of drug aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study is to evaluate the specificities of the irradiation of drugs in frozen aqueous solution. The structures of the degradation products were determined to gain insight into the radiolysis mechanisms occurring in frozen aqueous solutions. Metoclopramide hydrochloride and metoprolol tartrate were chosen as models. The frozen solutions were irradiated at dry ice temperature by high energy electrons at various doses. The drug purity (chemical potency) and the radiolysis products were quantified by HPLC-DAD. Characterization of the degradation products was performed by LC-APCI-MS-MS. The structures of the radiolysis products detected in irradiated frozen aqueous solutions were compared to those detected in solid-state and aqueous solutions (previous studies). For both metoclop...

2008-01-01

496

A comparative 90-day toxicity study of allyl acetate, allyl alcohol and acrolein  

British Library Electronic Table of Contents (United Kingdom)

Allyl acetate (AAC), allyl alcohol (AAL), and acrolein (ACR) are used in the manufacture of detergents, plastics, pharmaceuticals, and chemicals and as agricultural agents. A metabolic relationship exists between these chemicals in which allyl acetate is metabolized to allyl alcohol and subsequently to the highly reactive, a,b-unsaturated aldehyde, acrolein. Due to the weaker reactivity of the protoxicants, allyl acetate and allyl alcohol, relative to acrolien we hypothesized the protoxicants would attain greater systemic exposure and therefore deliver higher doses of acrolein to the internal organs. By extension, the higher systemic exposure to acrolein we hypothesized should lead to more internal organ toxicity in the allyl acetate and allyl alcohol treated animals relative to those trea...

2008-01-01