WorldWideScience
2

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

3

Simulation on energy deposition process due to anisotropic fast electron transport in high density plasma  

International Nuclear Information System (INIS)

Energy deposition process by relativistic fast electrons produced by ultra-intense laser pulses is discussed. The process is calculated with a two dimensional Fokker-Planck simulation code including binary and collective collisions coupled with electromagnetic field. We focused on Velocity Distribution Function (VDF) dependence in the simulation. The results show that the spread angle of the fast electrons distribution affects energy deposition area and deposited energy is concentrated in the vicinity of the propagation axis of the fast electrons. It may be also suggested that self-pinch effect of a fast electron beam causes large deposition energy. (author)

2008-03-01

4

A two-stage sequential linear programming approach to IMRT dose optimization  

UK PubMed Central (United Kingdom)

The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available

2010-02-07

5

Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems  

Energy Technology Data Exchange (ETDEWEB)

We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.

2006-03-06

6

Non-Linear Dose-Response Relationships in Biology, Toxicology and Medicine - An International Conference  

Energy Technology Data Exchange (ETDEWEB)

Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.

2002-05-28

7

Development of a fine and ultra-fine group cell calculation code SLAROM-UF for fast reactor analyses  

International Nuclear Information System (INIS)

A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous energy Monte Carlo calculations. It was ...

2006-08-01

8

Determination of heavy metals in welders' working environment using nuclear analytical methods  

International Nuclear Information System (INIS)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).

1985-01-01

9

Determination of heavy metals in welders' working environment using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.

1985-01-03

10

SLAROM-UF: Ultra fine group cell calculation code for fast reactor  

International Nuclear Information System (INIS)

A cell calculation code SLAROM-UF was developed to improve calculation accuracy of effective cross sections for various fast reactor types. SLAROM-UF has a capability to calculate effective cross sections in ultra fine groups of about 100,000 below 50keV and in fine groups above the energy (maximum 900 groups). Resonance interaction among the fuel, the coolant, and the structure materials can be treated accurately even in a heterogeneous cell structure. Temperature can be set up freely in a cell by the ultra fine group calculation. Improvement in nuclear characteristics was observed in the analysis of JUPITER critical experiment, as 0.1% for criticality, 4% for sodium void reactivity, several % for radial reaction rate distribution, when SLAROM-UF was used instead of the typical cell calculation code. The effect of the ultra fine group calculation is remarkable in the non-leakage term of sodium void ...

11

A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model  

International Nuclear Information System (INIS)

Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from ...

1997-08-01

12

Study of dose variation in various body parts with respect to chest dose in the working environment  

International Nuclear Information System (INIS)

Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)

2011-02-22

13

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT colonography also ...

2003-06-01

14

Verification of a nuclear analysis system for fast reactors using BFS-62 critical experiment  

International Nuclear Information System (INIS)

Critical experiments have been analyzed to verify a nuclear analysis system for fast reactors used in Japan Nuclear Cycle Development Institute (JNC). The experiments were performed in a collaboration work between JNC and the Institute of Physics and Power Engineering of Russia to dispose Russian surplus weapons plutonium, focusing on the effect of the introduction of uranium-plutonium mixed-dioxide (MOX) fuel and stainless steel reflector into the current BN-600 core that is comprised of UO_2 fuel and blanket. The analysis results agreed well with measured values on most of the nuclear characteristics. The accuracies are comparable to those obtained for the conventional MOX fueled fast reactors. It suggests that the JNC analysis system can analyze accurately nuclear characteristics in uranium fueled cores as well. A significant improvement was achieved on the sodium void reactivity by employing an ultra fine group cell ...

2004-12-01

15

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).

16

High-dose neutron-irradiation effects in fcc metals at 4.6 K  

International Nuclear Information System (INIS)

The rate of residual-resistivity increase and the isochronal recovery have been studied on the fcc metals Al, Ni, Cu, Pd, Ag, Pt, and Au irradiated at 4.6 K with reactor neutrons to a dose of about 10"1"9 (fast neutrons)/cm"2. The rate of resistivity increase is nonlinear as a function of irradiation-induced resistivity; computer analysis shows that the data are best fitted with an erxpression having up to third-order terms in #DELTA#rho. There are deviations from simple damage-rate theory in all cases, but an anomalous negative deviation from a linear law (convex curvature) is observed in Ni, Pd, Pt (and Fe). This behavior is most probably caused by a decrease of the specific Frenkel-defect resistivity due to defect clustering, an effect which should contribute in all metals after fast-neutron irradiation to high doses. Saturation values of resistivity and defect concentration as well as recombination ...

1977-12-01

17

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

18

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

21

Friction in ultra-thin conjunction of valve seals of pressurised metered dose inhalers  

British Library Electronic Table of Contents (United Kingdom)

In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...

2010-01-01

22

Fluence-convolution broad-beam (FCBB) dose calculation  

International Nuclear Information System (INIS)

IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple ...

2010-12-07

23

A comparative study on ultra-shallow junction formation using co-implantation with fluorine or carbon in pre-amorphized silicon  

Energy Technology Data Exchange (ETDEWEB)

The main driver in ultra-shallow formation for the 65 nm technology node and beyond is to find solutions that both reduce boron transient enhanced diffusion and can be integrated in the CMOS process flow. To this end, many studies have recently focused on using co-doping techniques with fluorine and most recently with carbon. In most cases, one or both of these is co-implanted with a dopant specie in pre-amorphized silicon. In this work, we show a comparative study of fluorine or carbon co-implanted with low-energy boron to form source and drain extension junctions for PMOS devices. We will show that by a systematic optimization of germanium, boron, fluorine or carbon energies and doses, spike annealing technology can be extended to the 65 nm node. These results will be used to discuss how the different formed junctions offer potential solutions for either low-power or high-performance PMOS device fabrication.

2005-12-05

24

Radiological operating experience at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.

1987-04-22

25

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for ...

1988-10-01

26

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

27

Ultra-fast charge transfer in organic electronic materials and at hybrid interfaces studied using the core-hole clock technique  

Energy Technology Data Exchange (ETDEWEB)

Research highlights: {yields} The use of resonant photoemission in its 'core-hole clock' expression for the study of the dynamical charge transfer across hybrid organic-inorganic interfaces and for the intermolecular charge transfer in the bulk of organic thin films is reviewed. {yields} The electronic coupling to the substrate and the efficiency of charge transport across hybrid interfaces is different for individual electronic subsystems of the molecular adsorbate. {yields} The intermolecular charge transfer in the bulk of discotic liquid crystals occurs on the order of a few femtoseconds and is faster than expected from the macroscopic charge transport characteristics of the material. -- Abstract: The focus of this brief review is the use of resonant photoemission in its 'core-hole clock' expression for the study of two important problems relevant for the field of organic electronics: the dynamical charge transfer across hybrid organic-inorganic ...

2011-01-15

28

CyberKnife SRS: new technologies that enhance the treatment of cancer  

International Nuclear Information System (INIS)

The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision

2008-11-26

29

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

30

Boron-enhanced-diffusion of boron: The limiting factor for ultra-shallow junctions  

Energy Technology Data Exchange (ETDEWEB)

Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).

1997-12-01

31

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

Mechanical properties of vanadium, irradiated with fast neutrons up to 8.6x10"-"4 dpa depending on postirradiation annealing temperature, are studied. It is shown that radiation-annealing hardening (RAH) is observed at 300 deg C, which agrees with earlier performed studies. It is first stated that RAH is accompanied by plasticity decrease. Phenomenological model permitting to explain RAH dependence on irradiation temperature and dose and also on content of chemically active alloying impurities is suggested.

32

Achieving cholesterol targets by individualizing starting doses of statin according to baseline low-density lipoprotein cholesterol and coronary artery disease risk category: The CANadians Achieve Cholesterol Targets Fast with Atorvastatin Stratified Titration (CanACTFAST) study  

UK PubMed Central (United Kingdom)

BACKGROUND:Despite an increasing body of evidence on the benefit of lowering elevated levels of low-density lipoprotein cholesterol (LDL-C), there is still considerable concern that...Full Text Available

2010-02-01

33

Ultra-thin lithium micro-batteries. Performances and applications; Microaccumulateurs ultra minces au lithium. Performances et applications  

Energy Technology Data Exchange (ETDEWEB)

This short paper (abstract) describes the characteristics and performances of prototypes of ultra-thin lithium micro-batteries (thickness < 0.2 mm) which can be incorporated into microelectronic circuits. (J.S.)

1996-12-31

34

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

35

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

36

Ultra High Strength Beta Titanium Alloy for Fasteners.  

Science.gov (United States)

... Accession Number : ADD151811. Title : Ultra High Strength Beta Titanium Alloy for Fasteners. Descriptive Note : Journal article,. ...

37

Dosimetric Implications of Atmospheric Dispersal of Tritium Near a Heavy-water Research Reactor Facility  

Energy Technology Data Exchange (ETDEWEB)

An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. Tritiated water ...

2001-07-01

38

Study of silicon damage caused by ultra-low energy boron implantation  

International Nuclear Information System (INIS)

Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as ...

39

Radiations emitted in the decay of /sup 165/Er: A promising medical radionuclide  

Science.gov (United States)

The 10.3-h /sup 165/Er, decaying by electron capture to stable /sup 165/Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in /sup 165/Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of /sup 169/Er and /sup 171/Er radioactive impurities in the reactor-produced /sup 165/Er sample are experimentally determined. Whole-body dose estimates for /sup 165/Er are given. These compare favorably with /sup 99/Tc dose.

1977-05-01

40

Radiations emitted in the decay of "1"6"5Er: A promising medical radionuclide  

International Nuclear Information System (INIS)

The 10.3-h "1"6"5Er, decaying by electron capture to stable "1"6"5Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in "1"6"5Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of "1"6"9Er and "1"7"1Er radioactive impurities in the reactor-produced "1"6"5Er sample are experimentally determined. Whole-body dose estimates for "1"6"5Er are given. These compare favorably with "9"9Tc dose.

41

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO_2 films  

International Nuclear Information System (INIS)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to obtain very shallow junctions. On the ...

42

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO[sub 2] films  

Energy Technology Data Exchange (ETDEWEB)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to obtain very shallow junctions. On the ...

1993-07-16

43

Activity patterns in elementary and high school students exposed to oxidant pollution  

Energy Technology Data Exchange (ETDEWEB)

We investigated activity patterns of 17 elementary school students aged 10-12, and 19 high school students aged 13-17, in suburban Los Angeles during the oxidant pollution season. Individuals' relationships between ventilation rate (VR) and heart rate (HR) were calibrated' in supervised outdoor walking/jogging. Log VR was consistently proportional to HR; although calibrations' were limited by a restricted range of exercise, and possibly by artifact due to mouthpiece breathing, which may cause overestimation of VR at rest. Each subject then recorded activities in diaries, and recorded HR once per minute by wearing Heart Watches, over 3 days (Saturday-Monday). For each activity the subject estimated a breathing rate--slow (slow walking), medium (fast walking), or fast (running). VR ranges for each breathing rate and activity type were estimated from HR recordings. High-school students' diaries showed their ...

1992-07-01

44

Improving T D reliability. How pumped storage can boost network security  

Energy Technology Data Exchange (ETDEWEB)

The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, provides 5000 acre-ft of active storage volume ...

1994-03-01

45

High-performance hybrid pervaporation membranes with superior hydrothermal and acid stability  

Energy Technology Data Exchange (ETDEWEB)

A new organic-inorganic hybrid membrane has been prepared with exceptional performance in dewatering applications. The only precursor used in the sol-gel synthesis of the selective layer was organically linked 1,2-bis(triethoxysilyl)ethane (BTESE). The microporous structure of this layer enables selective molecular sieving of small molecules from larger ones. In the dehydration of n-butanol with 5% of water, the membrane shows a high separation factor of over 4000 and ultra-fast water transport at a rate of more than 20 kg m{sup -2} h{sup -1} at 150C. This can be related to the high adsorption capacity of the material and the sub-micron thickness of the selective layer. The selectivity has now remained constant over almost one and a half years under continuous process testing conditions. Apart from the hydrothermal stability, the membrane exhibits a high tolerance for acid contamination. A slow performance decline in flux and separation factor is only observed at a ...

2009-05-15

46

The growth factor from plerocercoid larvae of the tapeworm, Spirometra mansonoides, stimulates growth but is not diabetogenic.  

Science.gov (United States)

A factor produced by plerocercoids of the tapeworm Spirometra mansonoides is similar to human growth hormone (hGH) in that it stimulates body growth, binds to hGH receptors, cross-reacts with anti-hGH antibodies, and has lactogenic and insulin-like activities. The purpose of this study was to determine whether plerocercoid growth factor (PGF) is similar to hGH in expressing diabetogenic activity in the genetically obese (ob/ob) mouse. To determine an effective dose for use in the obese mice, the ability of daily injections of PGF to stimulate growth of phenotypically normal mice of the same strain was assessed in a 10-day weight gain assay. Injections of PGF stimulated a dose-dependent weight gain (r = 0.83) and 25 ng eq/day of PGF stimulated a response not significantly different from that produced by 100 micrograms of bovine growth hormone/day. Diabetogenicity was assessed using fasting blood glucose and glucose tolerance ...

1989-06-01

50

Fostering the commercialization of ultra capacitors  

Energy Technology Data Exchange (ETDEWEB)

This document presents the activity of KiloFarad International (KFI), a trade association for the promotion of the interests of the international ultra-capacitor industry through education and representation. KFI provides a forum for the ultra-capacitor industry to work on non-competitive activities (standards, working groups, test procedures etc..). The rest of the document presents some informations about ultra-capacitors technology and some advanced applications in the automotive and telecommunication industries. (J.S.)

2004-07-01

52

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the ...

2007-03-15

53

Optimizing an analytical dose calculation algorithm for fast 2D calculations  

International Nuclear Information System (INIS)

Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the dose calculation model ...

54

The influence of treatment with thiotepa, thyroxine and D3 vitamin and the effect of fast neutron radiolysis on walker tumor chromatin  

International Nuclear Information System (INIS)

Anticancer drug thyotepa (10 mg/ kg) hormonal compound thyroxine (40 mg / kg) and D3 vitamin (30,000 IU / kg) have been administrated simply or associated to Wistar rats bearing Walker carcinosarcoma. The chromatin (the complex of DNA and proteins from nuclei) has been extracted from Walker tumor and submitted to fast neutron beams produced by deuterons (13 MeV) on thick Be target at an IPNE U-120 Cyclotron, in doses of 5-100 Gy. Thermal transition of chromatin fluorescence intensity of chromatin-ethidium bromide complexes and intrinsic fluorescence of chromatin have been analysed. Association of thiotepa with thyroxine and D3 vitamin produced a diminution of chromatin lesions induced by the cytostatic. Thus in the effects of fast neutrons radiolysis in chromatin significant differences occurred. These results could help to improve the methodology of associated chemotherapy-radiotherapy in clinical applications. (author).

1995-12-02

55

Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).

1996-12-31

56

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

57

FFTF shield and gamma ray measurements  

Energy Technology Data Exchange (ETDEWEB)

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

1984-08-01

58

CORE OF FAST BREEDER REACTOR  

J-STORE (Japan)

Full Text Available

2006-06-02

59

Issues on boron electrical activation in silicon: Experiments on boron clusters and shallow junctions formation  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive understanding of dopant activation mechanisms in crystalline Si is required in order to form shallow junctions. In this paper, we will review several experimental assessments on boron clustering and novel methods to form shallow junctions. Boron marker-layer structures have been used to investigate the fundamental aspects of formation and ripening boron-interstitial clusters (BICs) and their influence on the associated transient enhanced diffusion (TED). The samples were damaged by Si implants at different doses in the sub-amorphizing range and annealed at high temperatures. We found that BICs act as a sink for interstitials at supersaturations values S(t)>10{sup 4}. This implies that silicon self-interstitial defects are the primary source of interstitials driving TED, and that BICs act as a secondary 'buffer' for the interstitial supersaturation. These clusters are less sensitive to the ripening process than pure ...

2002-01-01

60

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the ...

2007-06-05

61

Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs  

International Nuclear Information System (INIS)

Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently interpolated into finer ...

2008-09-07

62

Optimization of advanced PMOS junctions using Ge, B and F co-implants  

International Nuclear Information System (INIS)

The main challenges for PMOS ultra shallow junction formation remain the transient enhanced diffusion (TED) and the solid solubility limit of boron in silicon. It has been demonstrated that low energy boron implantation and spike annealing are key in meeting the 90nm technology node ITRS requirements. To meet the 65nm technology requirements many studies have used fluorine co-implantation with boron and Si"+ or Ge"+ pre-amorphization (PAI) and spike annealing. Although using BF_2"+ can be attractive for its high throughput, self-amorphization and the presence of fluorine, many studies have shown that the fluorine successfully reduce TED, its energy needs to be well optimized with respect to the boron's, therefore BF_2"+ does not present the right fluorine/boron energy ratio for the optimum junction formation. In this work we optimize the fluorine energy for boron energies down to 200eV. We show the dependence of optimized junction on Ge"+ energies of 2keV and ...

2005-08-01

63

Mechanism of ageing in irradiated polymers  

Energy Technology Data Exchange (ETDEWEB)

Samples of ultra-high molecular weight polyethylene (UHMWPE) and nylon 66, of grades suitable for use in medical prostheses, were subjected to irradiation using a /sup 60/Co source. The effects of a 10 Mrad dose on percentage crystallinity, tensile behaviour and dynamic mechanical response were established 3 days after irradiation at intervals over a one year period. Crystallinity in UHMWPE was found to increase progressively during this period with consequent changes in mechanical behaviour. It is proposed that the observed ageing process arises from the breakdown of metastable groups in the polymer, which are formed on irradiation, with consequent release of long inter-lamella tie chains. This removes an inhibition to crystal perfection processes, which can occur at room temperature in polyethylene. Infra-red spectroscopic evidence supports the proposal that the metastable species is peroxy or hydroperoxy and that this decomposes on ageing to ...

1988-01-01

66

Remote tool applications at the FFTF [Fast Flux Test Facility] and the FFTF IEM [Interim Examination and Maintenance] Cell  

International Nuclear Information System (INIS)

Many types of maintenance activities are performed on contaminated (radioactive) machines and components at the Fast Flux Test Facility (FFTF). When personnel dose levels are within permissible limits, maintenance is performed in contaminated work areas or in gloveboxes. Otherwise, maintenance is performed in the Interim Examination and Maintenance (IEM) Cell, a hot cell that is used to perform tasks that require remote operation. Maintenance is often a combination of manual and remote operation. One such operation was the cleaning of the closed loop ex-vessel machine (CLEM) core component grapple (CCG). The CLEM is used to transfer core components in and out of the reactor vessel. The CCG had not been operating properly due to buildups of metallic sodium and sodium compounds on the outside surface and internal moving parts. This paper tells how the CCG was disassembled and cleaned. Part of this task was done in a glovebox and part in the IEM ...

1990-11-11

67

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light transmittance of the ...

1992-10-25

68

Low temperature irradiations in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The fusion materials program has little irradiation effects data at temperatures from 100 to 350 degree C. Near-term machines such as the International Thermonuclear Engineering Reactor (ITER) will expose materials to neutron doses of 38 to 50 dpa at 150 degree C or less. The data base for structural materials must be extended into this range. Also, lower temperatures are needed to investigate the lower bound for tritium release from solid breeder materials. A low temperature test vehicle is proposed for the Fast Flux Test Facility (FFTF), which will provide test temperatures of 100 to 350 degree C. An 8.5-cm dia. by 100-cm test volume will be instrumented to collect temperature data and provide feedback for control. The spectrum and flux will provide accelerated damage accumulation for structural materials testing and the best available approximation of fusion reactor conditions for solid breeder materials testing. Breeder samples can be ...

1988-10-09

69

Investigating of composition, structure and properties of Si modification under variable dose ions implantation influence  

International Nuclear Information System (INIS)

Interest to thin film of metals' silicides first of all is conditioned intrinsic al them unique physical properties. On their basis of it is possible to produce extremely sophisticated devices of solid-state electronics, production which needs the controlled change of physics, chemical and electrical properties with high-level of accuracy. On the present time most are in detail investigated composition, structure and properties of three-dimensional samples of metals' silicides. In the last years the intensive are led to researches in the direction of creation and study of physical-chemical properties thin (500-1000 Angstroms) and ultrafine (100-120 Angstroms) films silicides. It has information about composition, morphology of surface and emission of properties of thin film of silicides of barium, of cobalt and of palladium, was obtained in conditions of ultra-high vacuum. Low energy ion implantation and further annealing on composition, electronic and crystalline ...

70

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

71

Determination of fast neutron flux distribution in irradiation sites of the Malaysian Nuclear Agency research reactor  

British Library Electronic Table of Contents (United Kingdom)

Determination of thermal to fast neutron flux ratio (ffast) and fast neutron flux (phi-fast) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The ffast and subsequently phi-fast were determined using the absolute method. The ffast ranged from 48 to 155, and the phi-fast was found in the range 1.03x1010-4.89x1010 n cm-2 s-1. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.

2011-01-01

72

Ultra shallow P+/N junctions using plasma immersion ion implantation and laser annealing for sub 0.1#mu#m CMOS devices  

International Nuclear Information System (INIS)

Classical beam line ion implantation is limited to low energies and cannot achieve P+/N junctions requested for <45nm ITRS node. RTA (rapid thermal annealing) needs to be improved for dopants activation and damage reductions. Spike annealing process also induces a large diffusion mainly due to TED (transient enhanced diffusion). Compared to conventional beam line ion implantation limited to a minimum energy implantation of 200eV, plasma immersion ion implantation (PIII) is an emerging technique to get ultimate shallow profiles (as-implanted) due to no lower limitation of energy and high dose rate. On the another hand, laser thermal processing (LTP) allows to obtain very shallow junction with no TED, abrupt profile and activated depth control. In this paper, we show the implementation of the BF_3 PIII associated with the LTP. Ions from BF_3"+ plasma have been implanted in 200mm n-type silicon wafers with energies from 100eV to 1keV and doses ...

2005-08-01

73

Quantification of the influence of the choice of the algorithm and planning system on the calculation of a treatment plan  

International Nuclear Information System (INIS)

In this work an analysis of the influence of the choice of the algorithm or planning system, on the calculus of the same treatment plan is introduced. For this purpose specific software has been developed for comparing plans of a series of IMRT cases of prostate and head and neck cancer calculated using the convolution, superposition and fast superposition algorithms implemented in the XiO 4.40 planning system (CMS). It has also been used for the comparison of the same treatment plan for lung pathology calculated in XiO with the mentioned algorithms, and calculated in the Plan 4.1 planning system (Brainlab) using its pencil beam algorithm. Differences in dose among the treatment plans have been quantified using a set of metrics. The recommendation for the dosimetrist of a careful choice of the algorithm has been numerically confirmed. (Author).

74

Neutron and gamma-ray penetrations in thick iron  

Energy Technology Data Exchange (ETDEWEB)

Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.

1980-03-01

75

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

76

FFTF reactor characterization program  

International Nuclear Information System (INIS)

Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.

77

Degredation of superconductive properties in type A 15 compounds after irradiation  

International Nuclear Information System (INIS)

The influence of irradiation with 2.6 MeV H and He nuclei on the superconducting properties (critical temperature Tsub(c), critical current Isub(c)) of the intermetallic compound Nb_3Sn was studied. Irradiation led to a significant lowering of Tsub(c), while Isub(c) is increasing with the radiation dose. This is assumed to be due to the formation of active pinning centres in the lattice. There is a fast drop of Isub(c) after a peak value has been reached. Annealing of the samples (600-1,000"0C) led to an almost complete recovery of the initial value of Tsub(c). X-ray diffraction showed that irradiation causes considerable distortions of the lattice while the A15 crystal structure is retained. The causes of the radiation effects related to structural defects are discussed. (GSCH).

78

SERAPHIM: A propulsion technology for fast trains  

Energy Technology Data Exchange (ETDEWEB)

The Segmented Rail Phased Induction Motor (SERAPHIM) is a compact, pulsed linear induction motor (LIM) offering a unique capability for very high speed train propulsion. It uses technology developed for the Sandia coilgun, an electromagnetic launcher designed to accelerate projectiles to several kilometers per second. Both aluminum cylinders and plates were accelerated to a kilometer per second (Mach 3) by passing through a sequence of coils which were energized at the appropriate time. Although this technology was developed for ultra-high velocity, it can be readily adapted to train propulsion for which, at sea level, the power required to overcome air resistance limits the operational speed to a more modest 300 mph. Here, the geometry is reversed. The coils are on the vehicle and the ``projectiles`` are fixed along the roadbed. SERAPHIM operates not by embedding flux in a conductor, but by excluding it. In this propulsion scheme, pairs of closely spaced coils on ...

1995-06-01

79

Recovery of Tsub(c) by annealing of irradiated A-15 compounds  

International Nuclear Information System (INIS)

Data on the recovery of Tsub(c) for several neutron irradiated A-15 compounds are presented. A model for the mechanism of recovery is suggested and has been applied to isothermal annealing data at 550"0C on a sample of Nb_3Ge and to isochronal annealing (200"0C-900"0C) data on V_3Si, Nb_3Ge and Nb_3Sn subjected to varying doses of fast neutrons and on Nb_3Al of various compositions subjected to the same dose. The recovery is assumed to take place by vacancy assisted reordering and occurs in several stages. The major low temperature stage is attributed to irradiation induced vacancies, while at high temperatures there are depleted and recovery is ascribed to the motion of thermal equilibrium vacancies. Activation energies deduced for these processes, approximately 1 eV for vacancy motion and approximately 1-2 eV for vacancy formation, are consistent with what is known about diffusion in the A-15 structure. (Auth.).

80

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...

2007-04-01

84

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...

1983-01-01

85

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...

1983-01-01

86

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...

1983-01-01

87

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic ...

1989-08-15

88

Laser flash effects on chromatic discrimination in monkeys. Final report, April 1986-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Detecting a camouflaged target in a visually noisy background depends on the ability of the observer to discriminate the target from the surrounding terrain. Visible laser irradiation at less than damage levels can act as a masking source by compromising or reducing the observer's ability to resolve differences in the visual scene. Previous research has examined this concept by investigating laser flash effects on: acuity (size discrimination); tracking (motion discrimination); visual sensitivity (color); and contrast sensitivity functions (luminance contrast). In all cases, flashes from continuous-wave (CW) sources have proven more effective visually than pulsed (Q-switched) sources, when compared on peak-energy criteria (i.e., MPE), even though Q-switched lasers induce damage at lower energy doses. Additionally, the inherent safety of ultra-short laser pulses has been questioned. Past animal research has shown that, on the measures ...

1987-10-01

89

Defect engineering via ion implantation to control B diffusion in Si  

International Nuclear Information System (INIS)

The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the technological process to focus on the ...

2009-03-15

90

Ingestion dose for molybdenum: dependence on the administration form; Ingestionsdosis fuer Molybdaen: Abhaengigkeit von der verabreichten Form  

Energy Technology Data Exchange (ETDEWEB)

Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer Lebewesen essentielles Spurenelement, ...

1998-12-31

91

Biological Effects after Prenatal Irradiation  

International Nuclear Information System (INIS)

A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental retardation after exposures during the 8th to 15th week post conception in ...

92

A study on the development of hypo-stoichiometric Zr-based hydrogen storage alloys with ultra-high capacity for anode material of Ni/MH secondary battery  

Energy Technology Data Exchange (ETDEWEB)

Some hypo-stoichiometric Zr-based Laves phase alloys were prepared and studied from a viewpoint of discharge capacity for electrochemical application. After careful alloy design of ZrMn{sub 2}-based hydrogen storage alloys through changing their stoichiometry while substituting or adding some alloying elements, the Zr(Mn{sub 0.2}V{sub 0.2}Ni{sub 0.6}){sub 1.8} alloy reveals relatively good properties with regard to hydrogen storage capacity, hydrogen equilibrium pressure and electrochemical discharge capacity. In order to improve the discharge capacity and rate-capability, Zr is partially replaced by Ti. The discharge capacity of Zr{sub 1-x}Ti{sub x}(Mn{sub 0.2}V{sub 0.2}Ni{sub 0.6}){sub 1.8} (x=0.0, 0.2, 0.3, 0.4, 0.6) alloy electrodes at 30 C reaches a maximum value and decreases as the Ti fraction increases. In view of electrochemical and thermodynamic characteristics, the occurrence of a maximal phenomenon of the electrochemical discharge capacity of the alloy is attributed to a ...

2000-08-10

93

PV Conversion Technologies, Session: OPV, Sensitized, Seed (Presentation)  

Energy Technology Data Exchange (ETDEWEB)

The NREL Sensitized Solar Cell (SSC) Core Program supports the Solar America Initiative by: (1) targeting new devices and processes for commercialization by 2015 that are less expensive, more efficient, highly reliable, and environmentally benign; (2) collaborating with DOE OS/BES to conduct basic research targeting breakthroughs in key areas, such as ultra-high efficiency and/or ultra-low cost materials and devices.

2008-04-01

94

Individual monitoring of internal exposure to uranium oxides in two fuel fabrication plants. La surveillance individuelle de l'exposition interne aux oxydes d'uranium dans deux usines de fabrication du combustible  

Energy Technology Data Exchange (ETDEWEB)

Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of aerosol liable to intake with an ...

1989-01-01

95

Flowcytometry of {gamma}-ray irradiated mouse ovary  

Energy Technology Data Exchange (ETDEWEB)

This study was carried out to evaluate the biochemical and morphological effects of ionizing radiation on ovary. Immature mice (ICR, 3 week-old) were irradiated at a dose of LD{sub 80(30)} at KAERI. The ovaries were collected after 6 hours, 12 hours, 1 day, and 2 days post irradiation. To analyze the morphological changes, histological staining with hematoxylin-eosin, immuno- histochemical preparation using in situ 3'-end labeling was performed. DNA fragmentation analysis and flowcytometric evaluation of DNA extracted from whole ovary were performed. As a result of DNA fragmentation analysis, DNA fragments with 185, 370, and 555 base pairs were clearly shown at 6 hours post irradiation. The percentage of A{sub 0} cell cycle was significantly increased in the irradiated group than control. In situ 3'-end labeled follicles were increased at 6 hours post irradiation. The radiation-induced follicular atresia was taken place via an apoptotic ...

1998-10-01

96

The p14 FAST Protein of Reptilian Reovirus Increases Vesicular Stomatitis Virus Neuropathogenesis?  

UK PubMed Central (United Kingdom)

The fusogenic orthoreoviruses express nonstructural fusion-associated small transmembrane (FAST) proteins that induce cell-cell fusion and syncytium formation. It has been speculated that the FAST proteins...Full Text Available

2009-01-01

97

Complement-inhibiting and anti-inflammatory properties of chlorazole fast pink 2BL.  

UK PubMed Central (United Kingdom)

Chlorazole fast pink 2BL inhibited the classical complement pathway in rat serum both in vivo and in vitro. The in vitro potency of chlorazole fast pink against the alternative pathway could not be...Full Text Available

1981-02-01

98

Nitride Fuel for Fast Neutron Nuclear Reactors  

International Science & Technology Center (ISTC)

Development of Technology for Producing High-Effective Nitride Fuel UN with Controlled Microstructure for Advanced Fast Neutron Nuclear Reactors

100

Application of dose factors for decay chains  

International Nuclear Information System (INIS)

... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor

101

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

102

Machinability of magnesium alloy in ultra-precision diamond cutting  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with an experimental study of ultra-precision diamond cutting of magnesium alloy (AZ31). In order to investigate the machinability such as the cutting force and the surface integrity and understand the problems in a micro cutting, the experiments on the diamond cutting of magnesium alloy and pure aluminum with an ultra-precision turning machine has been carried out. The machinability of magnesium alloy was compared with that of pure aluminum and discussed. Consequently, both the thrust force component and the surface roughness obtained by cutting of magnesium alloy became larger than that of pure aluminum. It was also found that the inclusions or the defects in the work material caused to generate the scratches on the finished surface and influenced the integrity of mirror surface. (orig.)

2003-07-01

103

Identification of oxidation states of ultra-trace elements by radiation detection  

International Nuclear Information System (INIS)

The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.

1989-11-01

104

Corrosion resistance of Ultra-Low-Carbon 19% Cr-11% Ni stainless steel for nuclear fuel reprocessing plants in nitric acid  

International Nuclear Information System (INIS)

An Ultra-Low-Carbon 19% Cr-11% Ni Stainless Steels used in nuclear fuel reprocessing plants where highly corrosion resistance in nitric acid is required has been developed. This steel has optimized the chemistry composition to decrease inclusions and deformation-induced martensitic transformation. The formation of deformation-induced martensite has the potential danger of accelerating corrosion in nitric acid. In this paper, effects of cold reduction and martensitic transformation on corrosion resistance of Ultra-Low-Carbon Stainless Steels in nitric acid are discussed. The developed steel showed excellent corrosion resistance during long-term exposure to nitric acid. (author).

105

A numerical study of ultra-short-pulse reflectometry  

Energy Technology Data Exchange (ETDEWEB)

Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude density perturbation is assessed.

1994-05-01

106

Radiation resistance of flexible graphites  

International Nuclear Information System (INIS)

Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure natural graphite were found to be ...

107

"3H thymidine an indicator of benzo(a)pyrene induced lung carcinogenesis: role of quercetin and curcumin  

International Nuclear Information System (INIS)

Full text: Lung cancer is responsible for most of the cancer related deaths and calls for new approaches to control the menace. In the present study chemopreventive efficacy of curcumin and quercetin was investigated against benzo(a)pyrene (BP) induced lung carcinogenesis. The mice were segregated into five groups which included normal control, BP treated, BP+curcumin treated, BP+quercetin treated and BP+curcumin+quercetin treated groups. The morphological and histological analyses of tumor nodules confirmed lung carcinogenesis, after 22 weeks of single i.p. injection of BP at a dose of 100 mg/Kg body weight to mice. Tumor incidence and tumor multiplicity were observed to be 88% and 1.75, respectively in the BP treated mice. A statistically significant increase in the uptake of "3H thymidine indicative of increased DNA synthesis which in turn is the marker of uncontrolled cancer cell proliferation, was observed in the lung slices of BP treated mice. Further, BP ...

110

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is ...

111

System Design and Applications of the Ultra Small ... - GLTRS - NASA  

Science.gov (United States)

The advanced technologies of Ka-Band systems such as high gain spot .... sometimes used based on link requirements for a specific application. .... received at NASA LeRC from a Ku-band satellite and retransmitted to the USAT at Ka-Band. .... and to the Office of Management and Budget, Paperwork Reduction Project ...

112

Railgun. Challenge to ultra-high speed; Railgun. Chokosoku eno chosen  

Energy Technology Data Exchange (ETDEWEB)

A railgun has an armature driven between two rail-like conductors. In other words, it is a linear drive device system that drives airframes by using the Lorentz`s force. The system is expected as a next-generation high-speed transport means, or as a means to create such ultimate fields as ultra-high pressures, ultra-high temperatures, and ultra-ferromagnetic fields. This paper is a report on investigations on the relevant technological trends as surveyed by the investigation committee at the Institute of Electrical Engineers of Japan using research reports published inside and outside the country. The reported themes cover explanations from the construction to the pulse power supply that forms the core of the technology, problems in switching, recent status of research and development, and to application fields. Compatibility in the high-level electrical and mechanical performances demanded in the railgun is not as easy as ...

1995-09-12

113

Mesozoic Era of relativistic heavy ion physics and beyond.  

Science.gov (United States)

In order to understand how matter 15 billion years ago in the form of quarks, gluons and leptons at a temperature of 2 (times) 10(sup 12) (degrees)K evolved to become today's Universe, the goal of relativistic and ultra-relativistic heavy ion physics is t...

1994-01-01

114

Breaking the 1000-gene barrier for Mimivirus using ultra-deep genome and transcriptome sequencing  

UK PubMed Central (United Kingdom)

BackgroundMimivirus, a giant dsDNA virus infecting Acanthamoeba, is the prototype of the mimiviridae family, the latest addition to the family of the nucleocytoplasmic...Full Text Available

115

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

116

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

117

A fast multipole transformation for global climate calculations  

Energy Technology Data Exchange (ETDEWEB)

A fast multipole transformation is adapted to the evaluation of summations that occur in global climate calculations when transforming between spatial and spherical harmonic representations. For each summation, the timing of the fast multipole transformation scales linearly with the number of latitude gridpoints, but the timing for direct evaluations scales quadratically. In spite of a larger computational overhead, this scaling advantage renders the fast multipole method faster than direct evaluation for transformations involving greater than approximately 300 to 500 gridpoints. Convergence of the fast multipole transformation is accurate to machine precision. As the resolution in global climate calculations continues to increase, an increasingly large fraction of the computational work involves the transformation between spatial and spherical harmonic representations. The fast ...

1996-01-01

118

A Neuro-Fuzzy Multi Swarm FastSLAM Framework  

CERN Document Server

FastSLAM is a framework for simultaneous localization using a Rao-Blackwellized particle filter. In FastSLAM, particle filter is used for the mobile robot pose (position and orientation) estimation, and an Extended Kalman Filter (EKF) is used for the feature location's estimation. However, FastSLAM degenerates over time. This degeneracy is due to the fact that a particle set estimating the pose of the robot loses its diversity. One of the main reasons for loosing particle diversity in FastSLAM is sample impoverishment. It occurs when likelihood lies in the tail of the proposal distribution. In this case, most of particle weights are insignificant. Another problem of FastSLAM relates to the design of an extended Kalman filter for landmark position's estimation. The performance of the EKF and the quality of the estimation depends heavily on correct a priori knowledge of the process ...

2010-01-01

119

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

121

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

122

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

123

Use of the fast flux test facility for tritium production  

Energy Technology Data Exchange (ETDEWEB)

This report provides the results of a JASON review of the technical feasibility of using the Department of Energy`s (DOE`s) Fast Flux Test Facility (FFTF) to generate tritium needed for the enduring United States nuclear weapons stockpile.

1996-10-25

124

Plantago ovata Mucilage in the Design of Fast Disintegrating Tablets  

UK PubMed Central (United Kingdom)

In the present work, fast disintegrating tablets of prochlorperazine maleate were designed with a view to enhance patient compliance by direct compression method. In this method mucilage of Plantago...Full Text Available

2009-01-01

125

Fasting plasma magnesium concentrations and glucose disposal in diabetes.  

UK PubMed Central (United Kingdom)

Fasting plasma concentrations of magnesium were measured by neutron activation analysis in 30 non-diabetics and 87 diabetics (55 non-insulin-treated, 32 insulin treated). Plasma concentrations of magnesium...Full Text Available

1984-04-07

126

Fast-growing tropical hardwoods  

Energy Technology Data Exchange (ETDEWEB)

Forest research on fast growing Eucalyptus hybrids in the Congo, using coppice shoots for propagation, is described. The hybrids can grow 20 ft in 15 months and it is suggested that the application of such methods in Britain may increase the growth rates of hardwoods such as oak or walnut.

1980-07-01

127

Anisotropy of fission of /sup 242//sup m/Am by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

Careful measurements do not confirm an anomalous anisotropy in the angular distribution of fission fragments from the fast neutron fission of Americium 242. The energy range covered was 1.60-3.15 MeV. (AIP)

1985-10-01

128

Half-period optical pulse generation using a free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Recently there has been growth, in interest in non-equilibrium interaction of half-period long optical pulses with matter. To date the optical pulses have been produced by chopping out a half-period long segment from a longer pulse using a semiconductor switch driven by a femtosecond laser. In this paper we present new methods for producing tunable ultra-short optical pulses as short as half an optical period using a free-electron laser driven by electron bunches with a duration a fraction of an optical period. Two different methods relying on the production of coherent spontaneous emission will be described. In the first method we show that when a train of ultra-short optical pulses as short as one half period. We present calculations which show that the small signal gain is unimportant in the early stages of radiation build up in the cavity when the startup process is dominated by coherent spontaneous emission. To support our proposed method ...

1995-12-31

129

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...

2008-11-19

130

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

131

THIN FILM ACOUSTO-OPTIC DEVICES - REVIEW AND ...  

Science.gov (United States)

... Abstract : MANY THIN FILM ACOUSTO-OPTIC INTERACTION EXPERIMENTS FOR ... CONVERTERS, AND FOR FAST SWITCHES HAVE BEEN ...

1974-11-01

135

Fuel cycle of reactor SVBR-100  

International Nuclear Information System (INIS)

... fast reactors fbr type reactors fuels liquid metal cooled reactors materials nuclear

136

FAST LABORATORY DIAGNOSIS BY MEANS OF ...  

Science.gov (United States)

... negative diplooocci, to determine the type of pneumococi, to study staphylococa proteas, ehigla, sallmnefla, pasteurella, brucela, linters, leptosp ,s ...

1963-05-07

137

Nuclear medicine progress report for quarter ending March 31, 1985  

Energy Technology Data Exchange (ETDEWEB)

Radioiodinated 15-(p-iodophenyl)-3,3-dimethylpentadecanoic acid (DMIPP) has been prepared as a new terminal iodophenyl-substituted fatty acid containing dimethyl-branching at the beta-position. Iodine-125-labeled DMIPP showed rapid, high myocardial uptake (min, mean % injected dose/g) in fasted rats (5, 4.67; 30, 5.06; 60, 4.79; 120, 4.37), and also exhibited high heart:blood ratios (min, ratio) 5, 3:1; 30, 12:1; 60, 12:1; 120, 13:1. These data demonstrate an unanticipated much longer myocardial residence time with DMIPP (+/sub 1/2/ 7-8 h) than observed with either the 3-monomethyl (BMIPP) analogue (+/sub 1/2/ 30-45 min) or the rapidly metabolized straight-chain (IPP) analogue (+/sub 1/2/ 10-15 min). The (/sup 123/I)DMIPP is thus an excellent candidate for clinical evaluation of regional fatty acid metabolism under conditions where the uptake of energy substrates can be assessed independent of regional blood delivery. Studies with the new ...

1985-07-01

138

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

139

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

140

FastBit -- Helps Finding the Proverbial Needle in a Haystack  

Energy Technology Data Exchange (ETDEWEB)

FastBit is a software package designed to meet the searching and filtering needs of data intensive sciences. In these applications, scientists are trying to find nuggets of information from petabytes of raw data. FastBit has been demonstrated to be an order of magnitude faster than comparable technologies. In this brief report, we highlight how we work with a visualization team, a network security team and a DNA sequencing center to find the nuggets in their data.

2006-07-05

141

Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).

1987-01-01

142

Ultra-thin {sup 242m}Am fuel elements in nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

There is a growing interest in using {sup 242m}Am as a nuclear fuel. The advantages of {sup 242m}Am as a nuclear fuel derive from the fact that {sup 242m}Am has the highest thermal fission cross section. The thermal capture cross section is relatively low and the number of neutrons per thermal fission is high. These nuclear properties make it possible to obtain nuclear criticality with ultra-thin fuel elements. The possibility of having ultra-thin fuel elements enables the use of these fission products directly, without the necessity of converting their energy to heat, as is done in conventional reactors. There are three options of using such highly energetic and highly ionized fission products. - Using the fission products themselves for ionic propulsion. - Using the fission products in an MHD generator, in order to obtain electricity directly. - Using the fission products to heat a gas up to a high temperature for propulsion purposes. In this ...

2000-12-01

143

Ultra-high pressure water jet: Baseline report  

International Nuclear Information System (INIS)

The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of ...

1997-07-01

144

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...

2001-01-01

145

Investigation on boron transient enhanced diffusion induced by the advanced P{sup +}/N ultra-shallow junction fabrication processes  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P{sup +}/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B{sup +} and BF{sub 2}{sup +} ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF{sub 3} as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit ...

2005-08-01

146

Investigation on boron transient enhanced diffusion induced by the advanced P"+/N ultra-shallow junction fabrication processes  

International Nuclear Information System (INIS)

In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P"+/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B"+ and BF_2"+ ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF_3 as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit coming from PLAD ...

2005-08-01

147

H_2 emission arises outside photodissociation regions in ultra-luminous infrared galaxies  

CERN Document Server

Ultra-luminous infrared galaxies are among the most luminous objects in the local universe and are thought to be powered by intense star formation. It has been shown that in these objects the rotational spectral lines of molecular hydrogen observed at mid-infrared wavelengths are not affected by dust obscuration, leaving unresolved the source of excitation of this emission. Here I report an analysis of archival Spitzer Space Telescope data on ultra-luminous infrared galaxies and demonstrate that star formation regions are buried inside optically thick clouds of gas and dust, so that dust obscuration affects star-formation indicators but not molecular hydrogen. I thereby establish that the emission of H_2 is not co-spatial with the buried starburst activity and originates outside the obscured regions. This is rather surprising in light of the standard view that H_2 emission is directly associated with star-formation activity. Instead, I propose ...

2010-01-01

148

Effects of DC gate and drain bias stresses on the degradation of excimer laser crystallized polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V{sub GS} = V{sub DS}/2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted ...

2005-01-01

149

Effects of DC gate and drain bias stresses on the degradation of excimer laser crystallized polysilicon thin film transistors  

International Nuclear Information System (INIS)

The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V_G_S = V_D_S/2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted in ...

2005-01-01

150

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. Limitations of prevalent film dosimeters ...

151

Ultrashallow P{sup +}/N junction formation by plasma ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B{sub 2}H{sub 6} plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B{sub 2}H{sub 6} plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for ...

2000-12-01

152

Ultrashallow P"+/N junction formation by plasma ion implantation  

International Nuclear Information System (INIS)

We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B_2H_6 plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B_2H_6 plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for high-speed application ...

2000-12-01

153

NAME=\\  

Wastenet

...Synthesis of low-temperature, fast, single-firing body for porcelain stoneware tiles with coal gangue Synthesis of low-temperature, fast, single-firing body for porcelain stoneware ... tiles with coal gangue Synthesis of low-temperature, fast, single-firing body for porcelain stoneware tiles with coal gangue Wei et al.,... Article Synthesis of low-temperature, fast, single-firing body for porcelain stoneware tiles with coal gangue Qiangwei Wei1, Wenyuan Gao1*, and Xinguo ...According to phase diagram theory, a low-temperature, fast, single-firing body mix for porcelain stoneware tiles was designed in the quaternary system CaO-MgO-Al2O3-SiO2, using ...

154

Theoretical Standard Model Rates of Proton to Neutron Conversions Near Metallic Hydride Surfaces  

CERN Document Server

The process of radiation induced electron capture by protons or deuterons producing new ultra low momentum neutrons and neutrinos may be theoretically described within the standard field theoretical model of electroweak interactions. For protons or deuterons in the neighborhoods of surfaces of condensed matter metallic hydride cathodes, such conversions are determined in part by the collective plasma modes of the participating charged particles, e.g. electrons and protons. The radiation energy required for such low energy nuclear reactions may be supplied by the applied voltage required to push a strong charged current across a metallic hydride surface employed as a cathode within a chemical cell. The electroweak rates of the resulting ultra low momentum neutron production are computed from these considerations.

2006-01-01

155

Tailor die quenching in hot stamping for producing ultra-high strength steel formed parts having strength distribution  

British Library Electronic Table of Contents (United Kingdom)

Tailor die quenching in the hot stamping of quenchable steel sheets was developed to produce ultra-high strength steel formed parts having strength distribution. Local portions of the heated sheet were quenched by holding grooved tools at the bottom dead centre during the stamping. Non-contact portions were generated in the sheet by grooving the tools, and thus the strength in the contact portions is high owing to the quenching and that in the non-contact portions is low owing to the lack of the quenching. Hat-shaped products having a tensile strength of approximately 1.5GPa only at four corners were formed.

2010-01-01

156

Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint.

2007-11-15

157

Separation of rubidium from irradiated aluminum-encapsulated uranium  

International Nuclear Information System (INIS)

A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.

1993-05-01

158

Separation of rubidium from irradiated aluminum-encapsulated uranium  

Energy Technology Data Exchange (ETDEWEB)

A procedure was developed for separating rubidium from irradiated aluminum encapsulated uranium. The separations procedure produces a final ultra-high purity RbCl product for subsequent high performance mass spectrometric analysis. The procedure involves first removing most of the macro-components and fission products by strong base anion exchange using, first, concentrated HCl, then oxalic acid media and second, selectively separating rubidium from alkaline-earth ions and other alkali-metal ions, including cesium, using Bio-Rex-40 cation-exchange resin. The resultant RbCl is then put through a final vacuum sublimation step. Ultra-pure reagents and specially clean glassware are used throughout the procedure to minimize contamination by naturally-occurring rubidium.

1982-01-01

159

Production and characterization of ultrafine WC powders  

International Nuclear Information System (INIS)

The conventional Calzination-Reduction-Carburization (CRC) process offers the potential to manufacture commercial WC powders with median SEM grain sizes below 0.5 pm (ultra fine grades). Strict process control and a high degree of automation have led to increased powder uniformity and high lot-to-lot reliability. The high potential and flexibility of the CRC process is shown by the development of tailor made WC powders with regard to subsequent alloy manufacturing. R and D powders have successfully been processed in full-scale units exhibiting SEM grain sizes of 0.15 - 0.20 pm. This paper discusses the powder characteristics of various ultra fine WC powder grades, stemming from the conventional CRC process. Analytical characterization include also field-emission SEM, bright field TEM, EDX analysis and XRD-line broadening. (author)

2001-05-01

160

Mechanical properties and structure of low-alloy ultra-high strength steels  

Energy Technology Data Exchange (ETDEWEB)

Mechanical properties of P-LDHA and V-ROL N steels of the Czech production are compared with other ultra-high strength steels produced in the world. The most important results can be summarized into following points: 1. Optimally heat treated P-LDHA steel exhibits substantially better strength characteristics then the V-ROL N steel. 2. Optimal tempering temperature of the P-LDHA steel is 300 C. 3. Basic mechanical properties of P-LDHA steel belong to the top of the UHS steels ranking and are well comparable with those of American 300 M steel. 4. In the low-cycle fatigue region, the P-LDHA steel exhibits slightly better fatigue resistance then the 300 M steel. On the other hand, the high-cycle fatigue resistance of 300 M steel is slightly better then that of the P-LDHA steel. (orig.)

2000-07-01

161

Hydrogen transport and embrittlement in 300 M and AerMet100 ultra high strength steels  

Energy Technology Data Exchange (ETDEWEB)

This paper describes how hydrogen transport affects the severity of hydrogen embrittlement in 300 M and AerMet100 ultra high strength steels. Slow strain rate tests were carried out on specimens coated with electrodeposited cadmium and aluminium-based SermeTel 1140/962. Hydrogen diffusivities were measured using two-cell permeation and galvanostatic charging methods and values of 8.0 x 10{sup -8} and 1.0 x 10{sup -9} cm{sup 2} s{sup -1} were obtained for 300 M and AerMet100, respectively. A two-dimensional diffusion model was used to predict the hydrogen distributions in the SSR specimens at the time of failure. The superior embrittlement resistance of AerMet100 was attributed to reverted austenite forming around martensite laths during tempering.

2010-05-15

162

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

163

Aerogels from Unaltered Bacterial Cellulose: Application of scCO2 Drying for the Preparation of Shaped, Ultra-Lightweight Cellulosic Aerogels  

British Library Electronic Table of Contents (United Kingdom)

Bacterial cellulose produced by the gram-negative bacterium Gluconacetobacter xylinum was found to be an excellent native starting material for preparing shaped ultra-lightweight cellulose aerogels. The procedure comprises thorough washing and sterilization of the aquogel, quantitative solvent exchange and subsequent drying with supercritical carbon dioxide at 40 degreeC and 100 bar. The average density of the obtained dry cellulose aerogels is only about 8 mg cm-3 which is comparable to the most lightweight silica aerogels and distinctly lower than all values for cellulosic aerogels obtained from plant cellulose so far. SEM, ESEM and nitrogen adsorption experiments at 77 K reveal an open-porous network structure that consists of a comparatively high percentage of large mesopores and small...

2010-01-01

164

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of ...

2008-08-01

165

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

1981-06-01

166

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

167

Absorbed dose and dose reduction in mammography  

International Nuclear Information System (INIS)

First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).

1986-01-01

168

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

169

Evaluation of transient dose in conveyor type low dose irradiator  

International Nuclear Information System (INIS)

In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)

2003-03-05

170

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

171

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

172

Stochastic risk estimate for barium radiological examinations in Malaga (Spain)  

International Nuclear Information System (INIS)

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...

2000-01-01

173

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

174

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...

2001-04-01

175

Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.  

UK PubMed Central (United Kingdom)

Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available

1982-03-01

176

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

177

Effects of small doses of ionizing radiation on human health  

Energy Technology Data Exchange (ETDEWEB)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-12-01

178

Effects of small doses of ionizing radiation on human health  

International Nuclear Information System (INIS)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-01-01

179

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

180

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

181

The implementation of SOMO (SOlution MOdeller) in the UltraScan analytical ultracentrifugation data analysis suite: enhanced capabilities allow the reliable hydrodynamic modeling of virtually any kind of biomacromolecule  

UK PubMed Central (United Kingdom)

The interpretation of solution hydrodynamic data in terms of macromolecular structural parameters is not a straightforward task. Over the years, several approaches have been developed to cope...Full Text Available

2010-02-01

182

Steel microstructure engineering for large diameter tubes; Engenharia de microestrutura de acos para tubos de grande diametro  

Energy Technology Data Exchange (ETDEWEB)

High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)

2008-05-15

183

New designs for Ultra High High-Power Single Transverse Mode Cw fibre lasers  

International Nuclear Information System (INIS)

Overcoming the limiting constraints of stimulated Raman scattering (SRS) and stimulated Brilluoin scattering (SBS) poses serious fibre design challenges for increasing the output power of optical amplifiers and lasers. New fibre amplifier designs are proposed to break out of these limitations to reach several kWs CW powers. (Author)

2009-04-01

184

Nanophotonic components utilizing channel plasmon polaritons  

Science.gov (United States)

Channel plasmon polaritons (CPPs) propagating along the bottom of subwavelength grooves cut into a metal surface were recently shown to exhibit strong confinement combined with low propagation loss, a feature that makes this guiding configuration very promising for the realisation of ultra-compact photonic components. Here, the results of our investigations of CPP guiding by V-grooves cut into gold are presented, demonstrating efficient large-angle bending and splitting of radiation as well as waveguide-ring resonators and Bragg grating filters.

2008-08-01

185

Method of defining features on materials with a femtosecond laser  

Energy Technology Data Exchange (ETDEWEB)

The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.

2006-05-23

186

In situ spectroscopic and corrosion studies of ultra-thin gradient plasma polymer layers on zinc  

International Nuclear Information System (INIS)

By means of an audio frequency plasma polymerisation ultra-thin gradient plasma polymer layers were deposited on zinc and zinc-coated iron. The aim was to generate an interfacial polymeric layer which bonds to an oxidised metal as well as to a subsequently applied organic coating and acts as an interfacial barrier layer for ions and water. Surface modifications were done in an in situ plasma cell with infrared reflection absorption spectroscopy (IRRAS). The zinc surface was first activated by an oxygen plasma to provide a freshly oxidised and contamination free oxide surface. The intermediate stages of the surface reactions could be revealed. Carbon dioxide molecules as oxidation products adsorbed on the growing zinc oxide and were desorbed at a later stage. An organosilicon plasma polymer was deposited directly on top of the oxide layer from a hexamethyldisilane (HMDS) plasma. Afterwards a cyclohexene (CHEX)/hexamethyldisilane co-plasma polymer was deposited. The ...

2003-07-15

187

Determination of [sup 99]Tc in sea water at ultra low levels  

Energy Technology Data Exchange (ETDEWEB)

A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].

1994-01-20

188

A Theory of Laser Induced Nuclear Reaction in Single Atoms  

International Nuclear Information System (INIS)

An 'electron-bridge' mechanism of nuclear reaction in an atom or ion by ultra-intense laser fields is presented. A preliminary estimate of the intensity dependence of the rate of disintegration reaction of deuteron nucleus in deuterium atom is made for 800 nm laser fields. For intensities below 5x1021 W/cm2, the rate of disintegration by the 'electron-bridge' mechanism is found to be small, but it rises sharply and becomes large already for ?1022 W/cm2.

2010-02-02

189

On the Impact of Longitudinal Breathing Motion Randomness for Tomotherapy Delivery  

UK PubMed Central (United Kingdom)

The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available

2008-09-21

190

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) ...

2003-07-01

191

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

192

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and 64-detector row ...

2004-09-01

193

Development of Fast Spectrum Irradiation Facility for Fuels Development in the High Flux Isotope Reactor  

Energy Technology Data Exchange (ETDEWEB)

A concept for a fast spectrum irradiation facility has been developed for insertion in the High Flux Isotope Reactor at Oak Ridge National Laboratory. The design is based on the very large fast flux that is available in this reactor combined with the use of a strongly-absorbing thermal neutron shield. The preferred concept from the several considered consists of a three-pin design surrounded by a Eu{sub 2}O{sub 3} thermal neutron shield located in the reactor flux trap. Preliminary analyses showed that this concept can provide a fast flux larger than 1x10{sup 15} n/cm{sup 2}{center_dot}s and a fast-to-thermal flux ratio greater than 300 while having an acceptable impact on the HFIR operation. Additional analyses are necessary to confirm that this design is feasible and meets the requirements for fast fuel irradiation. If the design proves to be suitable, it can provide a relatively ...

2008-03-01

194

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...

2002-12-01

195

Effects of Multi-ion Irradiation on Microstructural Changes in Lithium Titanate  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Li{sub 2}TiO{sub 3} is regarded as one of the most suitable candidates for the solid tritium breeder material of D-T fusion reactors. It is known that, in an operating fusion reactor, the radiation damage in Li{sub 2}TiO{sub 3} will be caused by fast neutrons, energetic tritons and helium ions generated in {sup 6}Li(n,{alpha}){sup 3}H reaction. The irradiation damage caused by such radiation may result in the microstructural changes, and the changes may affect the characteristics of Li{sub 2}TiO{sub 3} such as tritium release behavior. Thus the study of irradiation defects and microstructural changes caused by irradiation in Li{sub 2}TiO{sub 3} is essential to evaluate its irradiation performance. Simulation of the fusion reactor environment and hence the study of a synergistic effect of atomic displacement damage in Li{sub 2}TiO{sub 3} are approached by a simultaneous irradiation with 'triple' ion beams which ...

2007-07-01

196

The interaction of fast N"+_2 ions with a Ni(111) surface  

International Nuclear Information System (INIS)

In the context of sputtering experiments, studying the back-scattering of fast ion beams is a useful way to study inelastic ion-surface interactions, since then the trajectories and energies of the particles are well defined. This same argument holds for the scattering of fast molecular ions. We give a short account of our experiment where N"+_2 was scattered from a Ni(111) surface. The measured energy distributions of scattered N atoms are discussed with regard to vibrational and rotational energy transfer during scattering. (G.Q.).

1986-02-01

197

Reactor physics results from fast flux test facility operation  

International Nuclear Information System (INIS)

Criticality was first achieved with the Fast Flux Test Facility (FFTF) a little more than 10 yr ago on February 9, 1980. Although the FFTF was designed and built primarily for testing fuels, materials, and components for the liquid-metal fast breeder reactor program, it has, over its first 10 yr of operation, provided valuable information in many other areas. This paper provides a summary of the contributions to the physics of liquid-metal reactors (LMRs) obtained from operation of and testing in the FFTF, with emphasis on some of the more significant and interesting accomplishments.

1990-11-11

198

Formation and decay of secondary actinides in water reactor and fast neutron reactors  

International Nuclear Information System (INIS)

Actinides other than the main uranium or plutonium isotopes take a growing part in the different stages of the nuclear cycle. For the French nuclear power program based on the development of light water reactors and fast breeders, many evaluations of the secondary actinides build up are made for the both reactor types using mainly the existing reactor codes. The comparison of these foreseen compositions with experimental results allows to perform some adjustments of the neutronic data. The secondary actinide compositions are given for some typical fuels and their consequences on the nuclear cycle are discussed. An hypothetical burning of these wastes in fast reactors has been studied and the main conclusions are reported.

199

Fast Neutral Pressure Measurements in NSTX  

Energy Technology Data Exchange (ETDEWEB)

Several fast neutral pressure gauges have been installed on NSTX [National Spherical Torus Experiment] to measure the vessel and divertor pressure during inductive and coaxial helicity injected (CHI) plasma operations. Modified, PDX [Poloidal Divertor Experiment]-type Penning gauges have been installed on the upper and lower divertors. Neutral pressure measurements during plasma operations from these and from two shielded fast Micro ion gauges at different toroidal locations on the vessel mid-plane are described. A new unshielded ion gauge, referred to as the In-vessel Neutral Pressure (INP) gauge is under development.

2002-08-06

200

FFTF operating experience 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 MWt sodium-cooled fast reactor operated by Westinghouse Hanford Company for the US Department of Energy to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor programme. Early in 1982, the FFTF began its first 100 day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94 per cent in the most recent irradiation cycle. The authors describe the results achieved in the first three cycles of operation and carrying through to the fourth reactor cycle which began in January 1984. (author).

201

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

202

An overview of FFTF [Fast Flux Test Facility] contributions to Liquid Metal Reactor Safety  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has provided a very useful framework for testing the advances in Liquid Metal Reactor Safety Technology. During the licensing phase, the switch from a nonmechanistic bounding technique to the mechanistic approach was developed and implemented. During the operational phase, the consideration of new tests and core configurations led to use of the anticipated-transients-without-scram approach for beyond design basis events and the move towards passive safety. The future role of the Fast Flux Test Facility may involve additional passive safety and waste transmutation tests. 26 refs.

1990-11-11

203

To Possibility of Usage of FMW Plasma Heating Scenarios in the ICR Frequency Range in the Torsatron Reactor  

International Nuclear Information System (INIS)

The problem of fast wave plasma heating in reactor-torsatron at the ICRF range in scenarios, optimal for fusion reactor, is numerically studied.

2006-01-01

204

Target stations and beam dumps for the CERN SPS  

International Nuclear Information System (INIS)

The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.

1977-03-16

206

Structural Response of Marine Sandwich Panels to Uniform ...  

Science.gov (United States)

... Composite sandwich panels with fiber reinforced plastic (FRP) faces and low 3 density foam cores are fast becoming the structural material of ...

1990-06-01

207

SPARSE SUPERPIXEL UNMIXING FOR EXPLORATORY - NASA  

Science.gov (United States)

Fast automated analysis of hyperspectral imagery can inform ... hyperspectral image analysis. .... atmospheric correction with the Crism Analysis Tool [11]. ...

208

Program for personnel protection from oxygen deficiency in a Fast Breeder Reactor Test Facility (FFTF)  

Science.gov (United States)

The FFTF reactor is described. Procedures and equipment used to protect personnel from potential hazards of oxygen deficient environments are described.

1979-12-12

209
210

Magnetohydrodynamic structure of a plasmoid in fast ... - NASA  

Science.gov (United States)

We set a symmetric boundary at x=200 and a conducting wall at z=150. The domain of 0200. 0150 is resolved by 60004500 grid cells. Harris sheet ...

213

Fast-Burning Rate/High Slope Propellant Technology ...  

Science.gov (United States)

... technique aBF n-Butyiferrocene P-33 Thermal carbon black PAP Porous Amnmonium Perchlorate Plastinox 711 Antioxidant ...

1971-04-01

215

Fast Flux Test Facility performance monitoring management information, April 1988  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators.

1988-05-01

216

Extension of the implicit curve-fitting method for fast calculation of thermodynamic properties of refrigerants in supercritical region  

Energy Technology Data Exchange (ETDEWEB)

The implicit curve-fitting method has been used for fast and stable calculations of thermodynamic properties of subcritical refrigerants, and it has to use the saturated liquid or vapor state as the reference state. In order to extend the application range of this method in supercritical region, an isothermal state in the supercritical region is used as the reference state, and the implicit equations for supercritical refrigerants in this state and out of this state are established, respectively. The new calculation method can be used in the entire supercritical region. With the new method, thermodynamic properties of supercritical CO{sub 2} and R410A are predicted and compared with REFPROP 8. It shows that the total mean relative deviations of the fast calculation formulae from REFPROP 8 are less than 1%, while the mean calculation speeds of the fast calculation formulae are more than 100 times faster than those of REFPROP ...

2009-11-15

217

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.

2011-02-01

218

Congodoma zairensis  

Science.gov (United States)

... zariensis is restricted to fast flowing water between Matadi and Kinshasa on the Zaire River. Although it ... region, where it was known from DRC at Matadi. DBL collections have recently extended its know...

219

Brief summary of reactor core component welding for the Fast Flux Test Facility (FFTF)  

International Nuclear Information System (INIS)

Included are descriptions of welding methods and joint design, welding equipment, and qualification tests.

1974-04-25

220

Actinide transmutation in nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.

1993-12-31

221

Actinide transmutation in nuclear reactors  

International Nuclear Information System (INIS)

Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.

1992-09-14

222

Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications  

International Nuclear Information System (INIS)

A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.

1996-07-15

225

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

226

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

227

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

228

Software means of dose consumption planning  

International Nuclear Information System (INIS)

Russian 2009 p. 118 Ukraine Mazilov, AV Stadnik, IA NSC 'Kharkiv

2009-02-23

230

Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses  

Energy Technology Data Exchange (ETDEWEB)

Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.

2007-11-15

231

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

233

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

Energy Technology Data Exchange (ETDEWEB)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.

1980-10-01

234

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

International Nuclear Information System (INIS)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).

1980-01-01

235

Effective dose equivalent in nuclear medicine investigations  

International Nuclear Information System (INIS)

... radiation hazards hazards health hazards MEDICINE. SOMATICALLY

1984-05-07

236

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

Energy Technology Data Exchange (ETDEWEB)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...

1993-05-01

237

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

International Nuclear Information System (INIS)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...

1993-01-01

240

Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV  

Energy Technology Data Exchange (ETDEWEB)

Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).

1989-01-01

241

Mammary carcinogenesis in the rat after low-dose irradiation  

International Nuclear Information System (INIS)

Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated ...

1992-07-12

242

Effect of dose on lead retention and distribution in suckling and adult female mice  

Energy Technology Data Exchange (ETDEWEB)

Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...

1980-01-01

243

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

244

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

245

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...

2006-04-01

246

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

247

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...

2006-04-01

248

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

249

The results of investigations in connection with development of methods for integrated optimization of fast reactors parameters  

International Nuclear Information System (INIS)

The results for development of methods and computer programs for integrated optimization of parameters of perspective fast reactors are given. The possibilities of the program for the reactor campaign calculation are analysed. This program is based on utilisation of the Bubnov-Galerkin method and Wigner disturbance theory. The possibility of application of approximation methods for the optimization researches is discussed. The results of development of the programs for complex reactor computations with account of control rods system and change of physical parameters in the reactor campaign are discussed. (author).

1974-07-01

250

Testing of evaluated transactinium isotope neutron data and remaining data requirements  

International Nuclear Information System (INIS)

The paper reviews the formation of minor actinides in light water and fast reactors, as well as the current status and recent improvements in the nuclear data for minor actinides, and compares recently evaluated data with experimental results. The paper also describes the qualification of nuclear data by post-irradiation analysis and integral measurements in fast critical assemblies. (author).

1985-05-01

251

Structure of fragment energy spectra in spontaneous fission of sup 242 Cm and fast-neutron fission of sup 242 m Am  

Energy Technology Data Exchange (ETDEWEB)

A technique for measurement of the energy spectra of fission fragments is discussed. The fine structure found in the spectra of fragments from spontaneous fission of {sup 242}Cm and fast-neutron fission of {sup 242{ital m}}Am is analyzed. The quantitative parameters of the structure and their analogy with the characteristics of cold fission are discussed.

1989-05-01

252

Searches for Fast Radio Transients  

CERN Document Server

We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.

2003-01-01

253

Radionuclide buildup in FFTF [Fast Flux Test Facility] heat transport system cells  

International Nuclear Information System (INIS)

The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.

1989-11-26

254

Liquid metal cooled fast breeder reactor comprising electromagnetic braking systems of the coolant flow  

International Nuclear Information System (INIS)

The liquid-metal-cooled fast breeder reactor presented includes a fuel assembly made up of several long sub-assemblies rising side by side. Each of the sub-assemblies of an external area of the fuel assembly comprises an electromagnetic braking system for regulating the flow of coolant in the sub-assembly, the magnetic fields of the braking systems being temperature sensitive.

255

Irradiation test program for FFTF  

International Nuclear Information System (INIS)

Four unique deisgn features are described which make the Fast Flux Test Facility eminently suitable for irradiation test programs. These features are a fast flux level of 7 x 10"1"5 neutrons/cm"2/sec, a 36-inch reference (breeder reactor) core height, test volumes suitable for testing of statistical quantities of materials, and the capability for direct (contact) or indirect (proximity) instrumentation of active core experiments.

256

HLMC Fast Reactor With Complete Natural Circulation  

Science.gov (United States)

To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute (JNC) and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. The Pb-Bi cooled complete natural circulation reactor concept may attain high safety level and construction cost goal (Yen 200,000/kWe) (authors)

2002-07-01

257

Foshan. A fast track combined cycle for Guangdong  

Energy Technology Data Exchange (ETDEWEB)

To meet growth in the fast developing Pearl River Delta economic zone in China`s Guangdong province, a 270 MW oil-fired combined cycle at Foshan was built and commissioned in only 22 months from financial closure. This article describes the Foshan power station, specifications, design, procurement, construction and operating concerns. 5 figs.

1995-03-01

258

Fast reactor fuel pin performance requirements for off-normal events  

International Nuclear Information System (INIS)

HEDL is conducting an experimental transient testing program to evaluate the performance of prototypic Fast Flux Test Facility (FFTF) fuel pins up to the cladding integrity limit. The relationship is described of the HEDL/TREAT transient overpower test program to the confirmation of FFTF fuel pin design bases via the FFTF fuel pin design procedure.

259

Development of LMFBR safety testing in FFTF  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) will provide a prototypic test environment for advanced fuels and materials development within the U. S. LMFBR program. As a fast test reactor, the FFTF also provides a potentially unique capability for conduct of safety experimentation relevant to selected LMFBR safety issues associated with postulated core disruption events. The utility and feasibility of possible extension of FFTF testing into the area of safety research is being investigated. 5 fig.

1976-10-01

260

Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system  

UK PubMed Central (United Kingdom)

The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available

2009-01-01

261

Calculation of neutron source strength in Fast Flux Test Facility fuel as a function of irradiation  

Energy Technology Data Exchange (ETDEWEB)

A method of calculating the neutron source strength in irradiated Fast Flux Test Facility (FFTF), fuel has been developed and is presented in this paper. This method has been used to perform calculations in support of the reactivity monitoring of the FFTF reactor by the modified source multiplication method during refueling operations. 31 refs.

1981-08-01

262

Analysis of a Fast Spectrum Irradiation Facility in the High Flux Isotope Reactor  

Energy Technology Data Exchange (ETDEWEB)

The Global Nuclear Energy Partnership (GNEP) is proposing to develop a sodium-cooled fast-spectrum reactor (SFR) to transmute and consume actinides from discharged nuclear fuel. To meet performance objectives, new and advanced fuels and targets need to be developed. The fuels to be irradiated include metal and oxide mixed actinides (U-Np-Pu-Am-Cm); for the target concept, Am-Cm has been considered. A significant part of the development process is the irradiation of the fuel and cladding in a prototypic fast reactor environment to determine the performance under irradiation. Analysis results are presented in this paper for a fast-neutron irradiation facility design based on the large fast neutron flux available in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) combined with the use of a strongly-absorbing thermal neutron shield. Several designs were assessed; the preferred ...

2008-09-01

263

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

Energy Technology Data Exchange (ETDEWEB)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 {mu}s) after reaching the stop band of the resonance. Dedicated experiments of fast failures of the main power converters ...

2010-07-01

264

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

International Nuclear Information System (INIS)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 #mu#s) after reaching the stop band of the resonance. Dedicated experiments of fast failures of the main power converters ...

2010-03-15

265

FastFlow: Efficient Parallel Streaming Applications on Multi-core  

CERN Document Server

Shared memory multiprocessors come back to popularity thanks to rapid spreading of commodity multi-core architectures. As ever, shared memory programs are fairly easy to write and quite hard to optimise; providing multi-core programmers with optimising tools and programming frameworks is a nowadays challenge. Few efforts have been done to support effective streaming applications on these architectures. In this paper we introduce FastFlow, a low-level programming framework based on lock-free queues explicitly designed to support high-level languages for streaming applications. We compare FastFlow with state-of-the-art programming frameworks such as Cilk, OpenMP, and Intel TBB. We experimentally demonstrate that FastFlow is always more efficient than all of them in a set of micro-benchmarks and on a real world application; the speedup edge of FastFlow over other solutions might be bold for fine grain ...

2009-01-01

266

Ultrathin coatings of nanoporous materials as property enhancements for advanced functional materials  

International Nuclear Information System (INIS)

This report summarizes the findings of a five-month LDRD project funded through Sandia's NTM Investment Area. The project was aimed at providing the foundation for the development of advanced functional materials through the application of ultrathin coatings of microporous or mesoporous materials onto the surface of substrates such as silicon wafers. Prior art teaches that layers of microporous materials such as zeolites may be applied as, e.g., sensor platforms or gas separation membranes. These layers, however, are typically several microns to several hundred microns thick. For many potential applications, vast improvements in the response of a device could be realized if the thickness of the porous layer were reduced to tens of nanometers. However, a basic understanding of how to synthesize or fabricate such ultra-thin layers is lacking. This report describes traditional and novel approaches to the growth of layers of microporous materials on silicon wafers. The ...

267

Technologies for high speed rolling and control of gauge in cold tandem mill for ultra-thin gauge strip; Gokuusu reikan atsuenki ni okeru kosoku atsuen gijutsu oyobi itaatsu seigyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

This paper describes high speed rolling and gauge control in cold tandem mill for ultra-thin gauge strip at the Chiba Works of Kawasaki Steel Corporation. To improve the plate-out property of rolling oil, cationic polymeric coagulant was prepared. Rolling oil with cohesion independent of inorganic inclusions or phosphatide was developed, to improve the lubrication for cold rolling, remarkably. In addition, a low-cost Ti-enhanced work roll having high wear resistance and excellent grindability was developed. Rolling can be conducted at the optimal rolling roughness and operation can be performed at the highest rolling speed independent of the rolling treatment amount. Rolling speed at 2800 m/min was confirmed by developing the rolling oil with excellent lubrication and the work roll having high wear resistance. For the improvement of strip thickness accuracy at the steady state rolling, use of the backup roll as roller bearing was more effective rather than the ...

1996-09-01

268

Studies of ultra-low energy electron-molecule collisions using very-high-n Rydberg atoms  

International Nuclear Information System (INIS)

Potassium atoms in selected high-lying np Rydberg states (80 #<=# n #<=# 400) are being used as a tool to examine electron-polar molecule collisions at ultra-low energies (#approx#80 #mu#eV - 1 meV). This energy regime has not been investigated previously and is of interest because the corresponding electron de Broglie wavelength is large, #approx#1300 - 330 Angstrom, and because the collision time is comparable to the period of molecular rotation. A variety of target molecules has been studied, including simple rotors such as HF, and more complex species such as NH_3, CH_3I, CH_2Br_2 and C_6H_5NO_2. These targets encompass a range of dipole moments and rotational behavior, but analysis of the data shows that in each case the cross section #sigma#(#epsilon#) for rotationally-inelastic electron-polar molecule scattering varies approximately as 1/#epsilon# where #epsilon# is the electron energy. Such threshold behavior is not predicted by the Born approximation ...

1993-05-16

269

Point defect engineering in preamorphized silicon enriched with fluorine  

International Nuclear Information System (INIS)

Fluorine is known to have a beneficial role for the B diffusion reduction in preamorphized Si, and is promising for the realization of ultra-shallow junctions. Thus, we studied the F incorporation in Si during the solid phase epitaxy (SPE) process, pointing out the effects of the implanted F energy and fluence and the role played by the possible presence of dopants. The incorporation of fluorine proceeds by F segregation at the amorphous-crystalline interface, with a kinetics driven by the SPE rate. In fact, the quicker the SPE rate, the higher is the F fluence retained. Moreover, we demonstrated that F incorporated in Si layers does not appreciably affect the Is emission from spatially separated end-of-range (EOR) defects. The modification, induced by the presence of F, of the point defect density (Is and Vs) was also studied by means of B and Sb spike layers, used as local markers for Is and Vs, respectively. We showed that F is not only able to completely ...

2006-12-01

270

Oxygen stabilization induced enhancement in superconducting characteristics of high-Tc oxides  

International Nuclear Information System (INIS)

In an attempt to enhance the electrical and mechanical properties of the high temperature superconducting oxides, high T(sub c) composites were prepared composed of the 123 compounds and AgO. The presence of extra oxygen due to the decomposition of AgO at high temperature is found to stabilize the superconducting 123 phase. Ag is found to serve as clean flux for grain growth and precipitates as pinning center. Consequently, almost two orders of magnitude enhancement in critical current densities were also observed in these composites. In addition, these composites also show much improvement in workability and shape formation. On the other hand, proper oxygen treatment of Y5Ba6Cu11Oy was found to possibly stabilize superconducting phase with T(sub c) near 250 K. I-V, ac susceptibility, and electrical resistivity measurements indicate the existence of this ultra high T(sub c) phase in this compound. Detailed structure, microstructure, electrical, magnetic and thermal ...

1991-01-01

271

Modelisation of boron diffusion from ultra-low-energy implantation in crystalline silicon  

Energy Technology Data Exchange (ETDEWEB)

We have investigated and modeled the boron diffusion in silicon following ultra-low-energy implantation (500 eV). It is well known that reducing implant energies is an effective way to eliminate transient enhanced diffusion due to the excess of interstitials from the implant. However, for sub-keV B implants diffusion remains enhanced. This enhancement is linked to the presence of a silicon boride layer located at the silicon surface which creates interstitials. This phenomenon is named 'boron enhanced diffusion' (BED). The BED effect is of obvious interest since it counteracts the advantage obtained by reducing the ion implantation energy. For these reasons, we have investigated the diffusion of low-energy boron implanted in crystalline silicon and tested a complete simulation program, which takes into account the effect of boron precipitation and the effect of the silicon boride layer as a source of self-interstitials. Experimental results have ...

2003-12-31

272

Leading research on supermetal. Part 1. Large-scale materials (iron system); Super metal no sendo kenkyu. 1. Ogata sozai (tetsukei)  

Energy Technology Data Exchange (ETDEWEB)

Supermetal with critical characteristics is under advanced investigation for further improvement of metal materials. Although iron is most frequently used as structural material among various metals, it should be used more carefully and effectively because of resource limitation and global environmental problem. It is essential to draw various excellent properties much more from iron and to improve recyclability. In particular, the best way to meet these requirements is achievement of more fine structure and higher purity. Since the lowest crystalline grain size is now limited to nearly 10{mu}m, metallic structure composed of grains below 1{mu}m is expected by mesoscopic control. Various methods have been studied to achieve ultra-fine crystalline structure, and study of precise heat treatment control and ultra-strength metallurgy is required. Heat treatment in magnetic field and layered structure by mechanical alloying are also promising. ...

1996-03-01

273

High-energy cosmic-ray nuclei from high- and low-luminosity gamma-ray bursts and implications for multi-messenger astronomy  

CERN Document Server

Gamma-ray burst (GRB) is one of the candidates of high-energy cosmic-ray acceleration sites. They may be also ultra-high-energy (above 3 EeV) cosmic-ray (UHECR) sources. In this paper, we discuss possibilities and implications of high-energy cosmic-ray acceleration in GRBs. (1) First, we show that not only protons but also heavier nuclei can be accelerated up to ultra-high energies in both usual high-luminosity (HL) and low-luminosity (LL) GRBs by using the Geant4. LL GRBs may also make a significant contribution to the observed UHECR flux if they form a distinct population, and we investigate cosmic-ray acceleration in LL GRBs in detail. (2) Second, we discuss implications of the GRB-UHECR hypothesis (and Hypernova-UHECR hypothesis) to cosmic-ray astronomy. HL GRBs and LL GRBs will lead to different source number densities as UHECR sources, so that the determination of the number density of UHECR sources and strength of the mean extragalactic ...

2008-01-01

274

High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A  

CERN Document Server

Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which may be related to ...

2009-01-01

275

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex D - Full-scale test of wind turbine blade, using sensors and NDT  

Energy Technology Data Exchange (ETDEWEB)

A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated damage. (au)

2002-05-01

276

Electrical properties of ultra-thin oxynitrided layer using N{sub 2}O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

Energy Technology Data Exchange (ETDEWEB)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that the ...

2007-06-04

277

Electrical properties of ultra-thin oxynitrided layer using N_2O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

International Nuclear Information System (INIS)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that the ...

2007-06-04

278

Effect of V and W addition on the high temperature strength properties of 12%Cr-15%Mn austenitic steels. 12%Cr-15%Mn austenite ko no ondo kyodo ni oyobosu V to W tenka no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Experimental discussions were given on effect of V and W addition on the high temperature strength properties of 12% Cr-15% Mn austenite steels. The test samples were added with W at 0% to 3.5% and V at 0% to 0.5% in addition to C and N, and were given aging treatment or solution treatment. This paper describes the following matters on the results of high-temperature strength measurements and structural observation: A remarkable trend was observed that M23 Cb type carbides precipitate in the aging treatment, wherein aging hardening appears prominently which is attributable to ultra-fine deposits of vanadium nitride (VN) in the V-added material; the V addition is very effective in increasing the high-temperature tensile strength and creep fracture strength as compared with single W addition, wherein the said carbides that accelerate the precipitation as a result of the V addition make a large contribution, in addition to that by ultra-fine VN ...

1992-11-01

279

Determination of the specific heat petroleum derivates; Determinacao do calor especifico de derivados ultrapesados de petroleo  

Energy Technology Data Exchange (ETDEWEB)

In the development of the specific mathematical modeling for heavy and ultra heavy petroleum fractions in a molecular distiller is very important the definition of physical and chemical parameters as density and specific heat of the mixture, the enthalpy of vaporization, among others, since they are used in the energy balance. Information on these properties and their variation with temperature are found in the open literature for mixture with few components (simple mixtures). However, for multicomponent solutions consisting of complex mixtures such as oil and its heavy and ultraheavy fractions, available data are few, or are limited to low temperatures. The specific heat is an important property in the energy balance. This property can be measured by Differential Scanning Calorimetry (DSC), which gives results with great sensitivity and accuracy. This paper presents the variation of specific heat with the temperature of ultra-heavy oil ...

2008-07-01

280

Conversion of a plasma enhanced chemical vapor deposited silicon-carbon-nitride thin film at ultra-low temperature by oxygen plasma  

Energy Technology Data Exchange (ETDEWEB)

In this work we present an ultra-low temperature method for the oxidation of an amorphous silicon-carbide-nitride (SiCN) material. The SiCN is deposited on silicon substrates by plasma enhanced chemical vapor deposition using CH{sub 4}, SiH{sub 4}, and N{sub 2} chemistry. The physical and chemical properties are characterized for the as-deposited SiCN and post-oxidized films are discussed. The SiCN film is exposed to oxygen plasma, where it undergoes a chemical transformation into a binary SiO{sub 2} material system. A 1.7 nm/min oxidation rate is typical for this process and compares favorably to oxidation methods utilizing much higher temperatures. The substrate temperature remains extremely low throughout the oxidation process, T{sub s} < 200 deg. C. Changes in film stress, optical constants, film thickness, surface roughness, and film density are measured. Chemical analysis by X-ray photoelectron spectroscopy is reported for both the as-deposited and ...

2008-01-30

281

Coherent Electromagnetic Processes in Ultra-Peripheral Heavy-Ion Collisions  

CERN Document Server

We report measurements for coherent rho^0 production, AuAu->AuAu rho^0, and coherent rho^0 and e^+e^- pair production accompanied by mutual nuclear Coulomb excitation, AuAu->Au*Au* rho^0 and AuAuee, in ultra-peripheral relativistic gold-gold collisions (UPC). We discuss transverse momentum, mass, and rapidity distributions. The two photon-process of e^+e^- pair production is an important probe of strong field QED because of the large coupling Z*alpha=0.6. At sqrt{s}=200GeV, the e^+e^- production cross section agrees with lowest order QED calculations. The cross sections for coherent rho^0 production at sqrt{s}=130 and 200GeV are in agreement with theoretical predictions. The calculations for both, coherent e^+e^- and rho^0 production treat nuclear excitation as independent process.

2004-01-01

282

Catalytic-adsorptive stripping voltammetric determination of ultra-trace iridium(III). Application to fresh- and sea-water  

British Library Electronic Table of Contents (United Kingdom)

An extremely sensitive stripping voltammetric procedure for ultra-trace determination of iridium(III) is reported. The method is based on the interfacial accumulation of the iridium(III)-CTAB complex onto the glassy carbon electrode, followed by the catalytic reduction of the adsorbed complex in the presence of bromate. 0.3molL^-^1 acetate buffer pH 4.7+6.9x10^-^2molL^-^1 NaBrO3+2.7x10^-^5molL^-^1 cetyltrimethylammonium bromide (CTAB)+0.2molL^-^1 KCl was employed as the supporting electrolyte. The analytical procedure was verified by the analysis of the standard reference materials: Sea Water BCR-CRM 403 and Fresh Water NIST-SRM 1643d. The accuracy, expressed as relative error e%, was satisfactory, being lower than 6%, while precision as repeatability, expressed as relative standard deviat...

2011-01-01

283

Analysis of algorithms for ultra high speed relays for the protection of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified version of the well known Electromagnetic ...

1984-01-01

284

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic advantages for MRT. (orig./MG).

285

"Mtrack 2.0": An ultra-scale tracking algorithm for low-resolution overhead imagery  

Energy Technology Data Exchange (ETDEWEB)

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery is very desirable. Typically, this imagery has many thousands of pixels on a side and is characterized by lower resolutions (e.g. {approx}0.5 meters/pixel to {approx}2.0 meters/pixel) and lower frame rates (e.g. {approx} sub-Hz to several Hz). We describe our ultra-scale capable implementation of a multiple-vehicle tracking algorithm for overhead persistent surveillance imagery. This work builds upon an earlier report, where now the algorithm has been modified for improved performance and has been substantially improved to handle much larger datasets in a much shorter time.

2008-09-26

286

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...

1991-01-01

287

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...

1991-11-01

288

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

Energy Technology Data Exchange (ETDEWEB)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...

2003-10-01

289

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

International Nuclear Information System (INIS)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...

2003-10-01

290

Medical irradiation and the use of the 'effective dose equivalent' concept  

International Nuclear Information System (INIS)

By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...

1980-03-01

291

{sup 242m}Am fueled nuclear battery  

Energy Technology Data Exchange (ETDEWEB)

A nuclear battery based on the direct energy conversion of the fission products is presented. Such energy conversion is possible by using a nuclear reactor with ultra-thin fuel elements of 0.2 {mu}m of {sup 242m}Am. The amount of nuclear fuel is 376 g and the dimensions of the battery are 2.4x2.4x2.4 m{sup 3} (including the vacuum spacing), with a BeO moderator and Be electrodes. The total power of the reactor is 10.6 MW and the electrical power is 0.652 MW.

2004-10-01

292

Ultra-thin {sup 242m}Am fuel elements in nuclear reactors. II  

Energy Technology Data Exchange (ETDEWEB)

There is growing interest in using {sup 242m}Am as a nuclear fuel for space reactors and nuclear batteries. In this paper, we discuss different {sup 242m}Am enrichments, as well as fuel weight requirements, to produce a critical reactor. It was found that relatively low enrichments of {sup 242m}Am, about 10 w/o, are enough to guarantee criticality. Such low enrichments might eliminate the need for a {sup 242m}Am enrichment process. It was also found that the best results for low {sup 242m}Am requirements are obtained with a moderator to fuel volume ratio of 10,000.

2004-04-21

293

Star Formation in the Outer Disks of Spiral Galaxies  

Science.gov (United States)

This is a study done in collaboration with Deidre Hunter at Lowell Observatory studying star formation in two luminous spiral galaxies NGC 801 and UGC 2885. We used ultra-deep H? images taken at the KPNO 2.1 m telescope. We compare these data to stellar images at various wavelengths and to HI maps to determine the extent of star formation activity into the outer disk in these galaxies and its relationship to the gas and older stars. TW is grateful for an REU internship during the summer of 2010 at Northern Arizona University, funded by NSF through grant AST-1004107.

2011-01-01

294

Problems and approach to geological disposal of radioactive waste  

International Nuclear Information System (INIS)

This feature articles described a concept and technical problems of geological disposal of high-level radioactive waste in the civil engineering. It consists of six papers such as the present statues and subjects of geological disposal by KITAYAMA Kazumi, the diastrophism, igneous activity, and upheaval and erosion by YAMAZAKI Haruo, the groundwater flow and evaluation of nuclear transfer by IJIRI Yuji, evaluation of alteration of cement materials in the ultra-long period by HAGA Kazuko, The Mizunami Underground Research Laboratory in course of construction by SAKAMAKI Masanori, and interview of the ninetieth president of JSCE (Japan Society of Civil Engineers), he places his hope on JSCE and civil engineers by KISHI Kiyoshi. (S.Y.)

2006-11-01

295

Orthophosphoric acid interactions with ultrastable zeolite Y: Infrared and NMR studies  

Energy Technology Data Exchange (ETDEWEB)

Zeolite Y is the active component of most commercial cracking catalysts. Interaction of H[sub 3]PO[sub 4] with extraframework aluminum of ultra-stable zeolite (USY) leads to the formation of different types of aluminum phosphates, while there is no indication of the formation of SAPO zeotype structures. The total acidity of USY slightly decreases upon the H[sub 3]PO[sub 4] treatment, while the maximum in the distribution of acid strength is shifted to milder acidities. Dealumination of the zeolite and creation of POH sites associated with AIPO[sub 4] are responsible for the modifications observed. 37 refs., 8 figs., 3 tabs.

1994-01-01

296

Multilayer ultra high gradient insulator technology  

Energy Technology Data Exchange (ETDEWEB)

We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.

1998-03-27

297

Improved formability of ultra high strength steels through local heat treatment  

Energy Technology Data Exchange (ETDEWEB)

In this paper it is described how a martensitic steel sheet with tensile strength of 1400 MPa is heat treated locally. The sheet is then formed in the heat treated regions in a way that would be impossible with the untreated material. Mechanical properties and forming limit diagrams of the heat treated material are determined and the forming operations are simulated, which shows that the method can be used by designers. Although the method has been known for decades, it remains to be industrialised and the work presented here is to be seen as a contribution to this development. (orig.)

2005-07-01

298

Enhancement of Heat and Mass Transfer in Mechanically Contstrained Ultra Thin Films  

Energy Technology Data Exchange (ETDEWEB)

Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of absorption and desorption systems can be ...

2005-01-01

299

Direct dark matter identification with a hybrid detection technique  

CERN Document Server

In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.

2008-01-01

300

Coverage and large scale anisotropies estimation methods for the Pierre Auger Observatory  

Energy Technology Data Exchange (ETDEWEB)

When searching for anisotropies in the arrival directions of Ultra High Energy Cosmic Rays, one must estimate the number of events expected in each direction of the sky in the case of a perfect isotropy. We present in this article a new method, developed for the Auger Observatory, based on a smooth estimate of the zenith angle distribution obtained from the data itself (which is essentially unchanged in the case of the presence of a large scale anisotropy pattern). We also study the sensitivity of several methods to detect large-scale anisotropies in the cosmic ray arrival direction distribution : Rayleigh analysis, dipole fitting and angular power spectrum estimation.

2005-07-01

301

Cosmic no hair for collapsing universes  

Energy Technology Data Exchange (ETDEWEB)

It is shown that all contracting, spatially homogeneous, orthogonal Bianchi cosmologies that are sourced by an ultra-stiff fluid with an arbitrary and, in general, varying equation of state asymptote to the spatially flat and isotropic universe in the neighbourhood of the big crunch singularity. This result is employed to investigate the asymptotic dynamics of a collapsing Bianchi type IX universe sourced by a scalar field rolling down a steep, negative exponential potential. A toroidally compactified version of M*-theory that leads to such a potential is discussed and it is shown that the isotropic attractor solution for a collapsing Bianchi type IX universe is supersymmetric when interpreted in an 11-dimensional context.

2006-05-21

302

Chloranilic acid as complex forming reagent for the ultra trace analysis of elements by adsorptive stripping voltammetry; Chloranilsaeure als Komplexbildner fuer die Ultraspurenanalyse von Elementen durch Adsorptions-Stripping-Voltammetrie  

Energy Technology Data Exchange (ETDEWEB)

It is reported about the adsorptive stripping voltammetric determination of uranium, antimony, tin, vanadium and molybdenum using chloranilic acid as complex forming reagent. The determination limits are in the l{sup 1}-range. (orig.) [Deutsch] Es wird ueber die Bestimmung von Uran, Antimon, Zinn, Vanadium und Molybdaen durch Adsorptions-Stripping-Voltammetrie mit Chloranilsaeure als Komplexbildner berichtet. Die Bestimmungsgrenzen liegen im ng l{sup -1} Bereich. (orig.)

1996-12-01

303

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the ...

2001-02-01

304

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...

2006-02-07

305

Ultra high vacuum test setup for electron gun  

Energy Technology Data Exchange (ETDEWEB)

Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and ...

2008-05-01

306

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, found at surfaces of ...

2005-04-01

307

Pressurized electroosmotic dewatering (PED) of fine coal suspensions  

Science.gov (United States)

Current dewatering methods for ultra-fine coal suspensions are inadequate and usually require subsequent expensive thermal drying. This unique dewatering method is based on pressurized electroosmosis, the movement of water by an electrical field through a porous medium, under modest pressure, e.g., 110 psi. More ultra-fine coal can be utilized since an effective dewatering process can be realized by combining known filtration techniques with electroosmosis. The dewatering efficiency can be significantly improved, the residual moisture of the cake can be substantially reduced and handling problems can be eliminated. Bench-scale testing is being used to optimize the parameters which influence pressurized electroosmotic dewatering (PED) of ultra-fine coal suspensions. Particle size distribution is being addressed to obtain a maximum density for a given pressure such that pore saturation is maintained allowing electroosmosis to ...

1985-01-01

308

The development of thyroid dose assessment software for nuclear or radiological emergency  

International Nuclear Information System (INIS)

Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)

2006-12-01

309

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the ...

310

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

311

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

312

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

313

Effect of Nordic diets on ECOSYS model predictions of ingestion doses  

British Library Electronic Table of Contents (United Kingdom)

The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...

2010-01-01

314

Dose enhancement in bone in electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

1984-05-01

315

Dose enhancement in bone in electron beam therapy  

International Nuclear Information System (INIS)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

316

Analysis of photon beam exit dose using photon point kernels  

International Nuclear Information System (INIS)

The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).

317

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let ...

2006-07-01

318

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed ...

2007-08-01

319

Fast breeder reactor safety : a perspective  

International Nuclear Information System (INIS)

Taking into consideration India's limited reserves of natural and vast reserves of thorium, the fast reactor route holds a great promise for India's energy supply in future. The fast reactor fueled with "2"3"9Pu/"2"3"8U (unused or depleted) produces (breeds) more fissionable fuel material "2"3"9Pu than it consumes. Calculations show that a fast breeder reactor (FBR) increases energy potential of natural uranium by about 60 times. As the fast reactor can also convert "2"3"2Th into "2"3"3U which is a fissionable material, it can make India's thorium reserves a source of almost inexhaustible energy supply for a long time to come. Significant advantage of FBR plants cooled by sodium and their world-wide operating experience are reviewed. There are two main safety issues of FBR, one nuclear and the other non-nuclear. The nuclear issue concerns core disruptive accident and the non-nuclear one concerns the ...

320

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

321

The antihypertensive efficacy and tolerability of a low dose combination of ramipril and felodipine ER in mild to moderate essential hypertension.  

UK PubMed Central (United Kingdom)

1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available

1993-10-01

322

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator ...

1996-12-01

323

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...

1976-01-01

324

Single-dose pharmacokinetics of ceftriaxone in healthy Chinese adults.  

UK PubMed Central (United Kingdom)

The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available

1985-02-01

325

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

326

Results of single and repeat dose studies of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers  

UK PubMed Central (United Kingdom)

AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available

1998-01-01

327

Range and modulation dependencies for proton beam dose per monitor unit calculations  

UK PubMed Central (United Kingdom)

Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available

2009-02-01

328

Radiation risks for medical applications  

International Nuclear Information System (INIS)

The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).

1980-05-31

329

Pneumocystis carinii pneumonia complicating low dose methotrexate treatment for rheumatoid arthritis.  

UK PubMed Central (United Kingdom)

Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available

1991-03-01

330

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

331

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

332

Milk residues and performance of lactating dairy cows administered high doses of monensin  

UK PubMed Central (United Kingdom)

AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available

2005-07-01

333

Methodology used to compute maximum potential doses from ingestion of edible plants and wildlife found on the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...

1990-10-01

334

Method of risk estimates for genetic, leukemogenic and carcinogenic effects from medical and occupational exposures  

International Nuclear Information System (INIS)

For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...

1980-01-01

335

Metabolism of iodomethane in the rat  

UK PubMed Central (United Kingdom)

1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available

1966-01-01

336

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient ...

1991-06-01

337

Low-Dose, Off-Label Drotrecogin Alfa (Xigris) In Severe Sepsis  

UK PubMed Central (United Kingdom)

Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available

2008-08-01

338

Low dose subcutaneous adrenaline to prevent acute adverse reactions to antivenom serum in people bitten by snakes: randomised, placebo controlled trial  

UK PubMed Central (United Kingdom)

ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available

1999-04-17

339

Long-term effects of inhaled uranyl nitrate in rats  

International Nuclear Information System (INIS)

Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.

1977-05-01

340

Isochron measurements of naturally irradiated K-feldspar grains  

International Nuclear Information System (INIS)

The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...

2007-09-01

341

Inhibition of exercise-induced asthma by nifedipine: a dose-response study.  

UK PubMed Central (United Kingdom)

1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available

1987-10-01

342

Induction of tumors by screening mammography  

International Nuclear Information System (INIS)

Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.

1983-01-01

343

Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983  

International Nuclear Information System (INIS)

Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10"4 man Sv. ...

1988-01-01

344

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

345

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...

1984-06-01

346

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...

1996-12-31

347

Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose  

UK PubMed Central (United Kingdom)

PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available

348

Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury  

UK PubMed Central (United Kingdom)

IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available

2009-01-01

349

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow ...

1980-10-31

350

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

351

A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers  

UK PubMed Central (United Kingdom)

Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available

2007-04-01

352

Transmutation of americium in fission reactors  

Energy Technology Data Exchange (ETDEWEB)

To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a heavy water reactor (HWR) has preference above irradiation in a PWR or in a high temperature gas-cooled reactor (HTGR). (authors) 4 refs.

1995-12-31

353

Transmutation of americium in fission reactors  

Energy Technology Data Exchange (ETDEWEB)

To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a HWR has preference above irradiation in a PWR or in a HTGR. (orig.).

1995-06-01

354

Radiological considerations of the reactor cover gas processing system at the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).

1986-09-24

355

Monte Carlo optimization technique applied to "2"3"8Pu production in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

An accurate neutronics calculation of a local thermal environment within a fast reactor presents a major challenge. A method was previously described that used Monte Carlo techniques within a macrocell to make accurate and reasonably efficient design calculations for such an environment. This method is now being further optimized for the calculation of "2"3"8Pu production in the Fast Flux Test Facility (FFTF). Here, it is not only important to determine the "2"3"8Pu production from neutron capture in "2"3"7Np, but also to calculate the production of the contamination isotope "2"3"6Pu from high-energy (n,2n) and (#gamma#,n) reactions. The power of the Monte Carlo method to automatically include geometry and energy self-shielding is retained by optimization using fission neutron source biasing in both space and energy.

1989-11-26

356

Five years operating experience at the Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.

1987-04-01

357

Five years operating experience at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.

1987-09-13

358

Fabrication of core demonstration experiments for irradiation in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

A major initiative to develop and irradiate a long-life, mixed-oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the US Department of Energy. The FFTF, shown in Figures 1 and 2, is a 400 megawatt thermal, fast liquid metal reactor that tests liquid metal, space and fusion fuels and materials. The new fuel system, called the Core Demonstration Experiment (CDE) demonstrates the capability of achieving a three- to four-year life in a prototypic heterogeneous reactor environment under prototypic power and temperature conditions. This fuel system will greatly increase fuel performance and lifetime from the current standard FFTF driver fuel. New design features, fabrication development, CDE assembly fabrication, and irradiation status have been described.

1990-06-10

359

FFTF scale-model characterization of flow-induced vibrational response of reactor internals  

International Nuclear Information System (INIS)

As an integral part of the Fast Test Reactor Vibration Program for Reactor Internals, the flow-induced vibrational characteristics of scaled Fast Test Reactor core internal and peripheral components were assessed under scaled and simulated prototype flow conditions in the Hydraulic Core Mockup. The Hydraulic Core Mockup, a 0.285 geometric scale model, was designed to model the vibrational and hydraulic characteristics of the Fast Test Reactor. Model component vibrational characteristics were measured and determined over a range of 36 percent to 111 percent of the scaled prototype design flow. Selected model and prototype components were shaker tested to establish modal characteristics. The dynamic response of the Hydraulic Core Mockup components exhibited no anomalous flow-rate dependent or modal characteristics, and prototype response predictions were adjudged acceptable.

360

FFTF operating experience, 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some in excess of 80 MWd/Kg.

1984-04-09

361

Development of linear sensitivity matrix method for fast evaluation of CANDU refuelling schemes  

International Nuclear Information System (INIS)

In order to develop a numerical tool for the fast evaluation of CANDU refuelling schemes, a Linear Sensitivity Matrix method (LSM) is developed. It assumes that all the effects caused by various perturbations to the core state are independent to each other and the core response to a perturbation is proportional to its magnitude. In this way, the main core parameters of a refuelling scheme can be derived by simple algebraic operations with the use of pre-calculated sensitivity matrices, without resorting to the complicated and time-consuming 3D core calculation. Verification against the Qinshan CANDU reactor operation history demonstrates that LSM is capable of generating accurate results and running very fast for evaluating a refuelling scheme. (authors)

2009-06-01

362

Cross-section libraries and analysis of fast reactor benchmarks  

International Nuclear Information System (INIS)

Using indigenously developed computer program, coupled neutron gamma multi-group libraries have been generated from MA TXS-NJOY files. The MATXS format contains all the details for each reaction. Temperature and dilution factor dependent cross-sections have been generated and used in discrete ordinates method for benchmark studies of fast critical experiments. We have analyzed criticality benchmarks, which includes CSEWG fast critical benchmarks, "2"3"3U and Pu spheres and enriched uranium spheres using 30-group neutron cross-sections. Neutron and gamma spectra for spheres with point neutron source at the center, are also calculated with 42-group coupled neutron gamma cross-sections. (author)

2005-11-01

363

Bimodal colloidal mixtures: From fast to slow aggregation regions  

British Library Electronic Table of Contents (United Kingdom)

A Brownian dynamics simulation has been used to investigate the aggregation kinetics of bimodal colloidal mixtures with similar surface chemistries but different sizes, driven by the DLVO interaction potential. The time evolution of structural formation is examined by the mean number of neighbors under fast and slow aggregation regions. It was found that the electrolyte ionic strength affects the kinetic pattern of colloidal aggregation. Under the high electrolyte ionic strength conditions (fast aggregation), the selective aggregation of the least stable single component can take place in the early stage, while the other component is enriched in this least stable component in the later stage. With the ionic strength decreasing (towards the slow aggregation), the hybrid aggregation (selecti...

2011-01-01

364

A Fast Ionization Chamber for Fission Cross-Section Measurements at n(_)TOF  

International Nuclear Information System (INIS)

An ionization chamber with fast timing properties was built at CERN for measuring fission cross-sections of minor actinides at the n(_)TOF neutron beam. The design of this new chamber and of the front-end electronics was optimized to match the innovative features of the n(_)TOF facility, in particular the high instantaneous neutron flux and low background. For the most radioactive isotopes, a special version of the chamber, designed according to the ISO2919 standards, was built in order to comply with the radioprotection requirements at CERN. The detector and front-end electronics are here described, together with the simulated and measured response to fission fragments and #alpha#-particles. The performances of the chamber during the first measurement campaign at n(_)TOF are presented, focusing in particular on the fast time response, the good background rejection capability, low-background and high detection efficiency.

2008-09-01

365

The circadian rhythm for the number and sensitivity of radiation-induced apoptosis in the crypts of mouse small intestine  

Energy Technology Data Exchange (ETDEWEB)

Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).

1990-07-01

367

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

368

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

369

Serum Creatine Phosphokinase Activity after Intramuscular ...  

Science.gov (United States)

... Title : Serum Creatine Phosphokinase Activity after Intramuscular Injection: The Effect of Dose, Concentration, and Volume. ...

1974-01-01

370

Savannah River Site dose control  

Energy Technology Data Exchange (ETDEWEB)

Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.

1992-01-01

371

Savannah River Site dose control  

Energy Technology Data Exchange (ETDEWEB)

Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.

1992-06-01

372

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

373

Retrospective Monte Carlo dose calculations with limited beam weight information  

International Nuclear Information System (INIS)

An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography densities. Validation ...

2007-01-01

374

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

375

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

376

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

377

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

378

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

379

Measuring relative probability of Am-242 #beta#-decay  

International Nuclear Information System (INIS)

... americium 241 americium 242 beta decay chain reactions integral doses mass

381

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue  

International Nuclear Information System (INIS)

Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...

2003-10-01

382

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

384

CHAPTER 1 - NASA  

Science.gov (United States)

However, market based pricing doses not apply where the pricing .... the reimbursable work, market based pricing does not apply. 040202. ...

385

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

386

A marine compartment model for collective dose assessment of liquid radioactive effluents  

International Nuclear Information System (INIS)

A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).

1982-01-01

388

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

389

Population exposure to external natural radiation background in the United States  

Energy Technology Data Exchange (ETDEWEB)

This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.

1981-04-01

390

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three ...

1981-01-01

391

Phase I Study of Conformal Radiotherapy and Concurrent Full-Dose Gemcitabine with Erlotinib for Unresected Pancreatic Cancer.  

Science.gov (United States)

PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting ...

2011-05-01

392

Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT  

International Nuclear Information System (INIS)

With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of absorbed dose, the ...

2007-08-01

393

Occupational exposure information system in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)

2005-07-01

394

Non-linearity of pre-dose response and its effects on TL dating  

Energy Technology Data Exchange (ETDEWEB)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-15

395

Non-linearity of pre-dose response and its effects on TL dating  

International Nuclear Information System (INIS)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-01

396

Mechanism of radiation induced carcinogenesis: does a threshold exist?  

International Nuclear Information System (INIS)

Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).

1996-10-23

397

Howard Hughes Medical Institute dose assessment survey  

Energy Technology Data Exchange (ETDEWEB)

Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs.

1996-12-01

398

Estimations of population doses and risk estimates from occupational exposures in Japan, 1978, 2  

International Nuclear Information System (INIS)

The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 man rem for non-destructive inspectional, ...

1981-01-01

399

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

400

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography  

International Nuclear Information System (INIS)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.

1999-05-01

401

Development of a site-specific following accident dose assessment system  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project to interface the site-specific real-time radiological dose assessment system FADAS(Following Accident Dose Assessment System) to CARE. In this study, the results of the field tracer experiments conducted on the Younggwang site have been analysed. And the experimental procedure on Ulchin site has been introduced. The environmental characteristics on Ulchin and Wolsung has been investigated.

1997-12-15

402
403

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed ...

2004-12-01

404

27: Development of a convolution/superposition method for photon beams  

International Nuclear Information System (INIS)

The implementation of the convolution/superposition method in real dose planning situations is considered. The modelling of photon spectra, the use of patient and treatment setup information, and the calculation of the photon energy released in a patient are detailed. A comparison is made between the approaches of calculating the relative dose directly and using a factor derived from measurements to correct the calculated relative dose. 13 refs.; 7 figs.

405

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a ...

2004-12-01

406

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels  

International Nuclear Information System (INIS)

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes ...

2005-02-21

407

Yes, Virginia, There Is a Paper Record!  

UK PubMed Central (United Kingdom)

This tongue-in-cheek essay hopes to prompt discussion among health information management (HIM) professionals of all levels with regard to the fast-changing HIM landscape, particularly the electronic...Full Text Available

408

Why were "starvation diets" promoted for diabetes in the pre-insulin period?  

UK PubMed Central (United Kingdom)

In the decade before the discovery of insulin, the prominent American physicians Frederick Allen and Elliott Joslin advocated severe fasting and undernutrition to prolong the lives of diabetic patients....Full Text Available

409

Web report.qxd  

Wastenet

the exchange of experience and ideas in the social, political and economic areas. ...the fast-changing, high-risk and short-term nature of these network relationships is seen to conflict with the slow ...incremental process of change characteristic of the German social-market model.

410

The Non-linear Relationship between Gait Speed and Falls: The MOBILIZE Boston Study  

UK PubMed Central (United Kingdom)

OBJECTIVESAlthough several studies suggest that slow gait speed is a predictor of falls, it may also be a protective mechanism to prevent falls. Further, fast walking...Full Text Available

2011-06-01

411

The Genetic Basis of Cellular Morphogenesis in the Filamentous Fungus Neurospora crassa  

UK PubMed Central (United Kingdom)

Cellular polarity is a fundamental property of every cell. Due to their extremely fast growth rate (≥1 μm/s) and their highly elongated form, filamentous fungi represent a prime example...Full Text Available

2003-11-01

412

Studies of neutron dosimetry  

Energy Technology Data Exchange (ETDEWEB)

A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).

1997-04-01

413

Stable Isotope-Coded Quaternization for Comparative Quantification of Estrogen Metabolites by High-Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry  

UK PubMed Central (United Kingdom)

A fast and sensitive LC-ESI-MS method is described for the comparative quantification of 16 estrogen metabolites based on the derivatization of estrogens with a novel derivatizing reagent, N-methyl-nicotinic...Full Text Available

2008-07-15

414

Shield-verification survey of a large hot cell at the FFTF  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.

1980-01-01

415

SEE Characterization of the Samsung K4F660812 DRAM ... - NEPP - NASA  

Science.gov (United States)

the Samsung K4F660812 DRAM were measured by the JPL Radiation Effects. Group [1] . ... The Samsung K4F660812 is a 8 x 223 bit Fast Page CMOS DRAM. The two- ...

416

SCALER WITH RESOLUTION TIME EQUAL TO 10 NANOSECONDS  

Science.gov (United States)

In systems of fast decimal counters, there are three problems to be resolved: to study a bistable having a short switching time, to form with the aid of three bistables a circuit divisible by 5, and to normalize the input pulses. The solutions to these problems for the nonsecond scaler are presented. (J.S.R.)

1960-01-01

417

Revised neutron dosimetry results for the MOTA-2A experiment in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.

1994-09-01

418

Review of integral data on higher transactinides  

International Nuclear Information System (INIS)

A review of the status of integral measurements is presented for "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"1Am and "2"4"3Am. This review includes integral measurements pertinent to thermal reactor systems, i.e., thermal cross sections and resonance integrals, as well as measurements for fast reactor systems. It appears that for these nuclides the data for thermal reactors are in good shape; however, more work is recommended in defining the branching ratio of the capture cross section of "2"4"1Am to the isomeric and ground states of "2"4"2Am. Also, benchmark irradiation data are needed for cross section data testing using depletion/production codes. For fast reactors, experiments are in progress, in the UK, in France, and also in the US, with partial results available at this time. Fast integral data obtained from these measurements will be very beneficial. The recommendation pertaining to "2"4"1Am and proper benchmarks for thermal ...

1979-05-01

419

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained ...

0854-01-01

420

Preparation and Evaluation of Microencapsulated Fast Melt Tablets of Ambroxol Hydrochloride  

UK PubMed Central (United Kingdom)

Natural resources in general and plant materials in particular are receiving more attention due to their safety as pharmaceutical excipients. Present work assessed the potential of a natural polysaccharide,...Full Text Available

2009-05-01

421

Phenothiazine-N-carbonyl chloride, a specific inactivator of chymotrypsin  

UK PubMed Central (United Kingdom)

Phenothiazine-N-carbonyl chloride inactivated chymotrypsin and trypsin by means of a 1:1 stoicheiometric reaction. Its reaction with chymotrypsin was 29 times as fast as that with...Full Text Available

1970-07-01

422

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

423

New approach to study fast and slow motions in lipid bilayers: application to dimyristoylphosphatidylcholine-cholesterol interactions.  

UK PubMed Central (United Kingdom)

Natural abundance 13C solid-state nuclear magnetic resonance spectroscopy was used to investigate the effect of the incorporation of cholesterol on the dynamics of dimyristoylphosphatidylcholine (DMPC)...Full Text Available

1995-05-01

424

Monitoring digoxin therapy: I. Plasma concentrations and an in vitro assay of tissue response.  

UK PubMed Central (United Kingdom)

1 An in vitro technique is described for measuring the uptake of 86Rb by human erythrocytes. 2 Fifteen patients were treated with digoxin for atrial fibrillation and other fast arrhythmias. 3 86Rb uptake...Full Text Available

1977-04-01

425

Mass spectrometric characterization of high-temperature outgassing of anisotropic pyrolytic boron nitride  

International Nuclear Information System (INIS)

This paper describes a system for fast mass spectrometric characterization of high-temperature outgassing measurements and measuring the total quantity of gas evolved for boron nitride. 2 references, 1 figure, 2 tables.

426

Large plasmids of fast-growing rhizobia: homology studies and location of structural nitrogen fixation (nif) genes.  

UK PubMed Central (United Kingdom)

A single large plasmid was isolated from multiplasmid-harboring strains Rhizobium leguminosarum 1001 and R. trifolii 5. These single plasmids, as well as the largest plasmid detectable in R. phaseoli...Full Text Available

1981-03-01

427

Insulin increases glucose transfer across the blood-brain barrier in man.  

UK PubMed Central (United Kingdom)

The influence of insulin on unidirectional flux of glucose across the blood-brain barrier and on net uptake of glucose by the brain was investigated in seven fasting patients. The unidirectional extraction,...Full Text Available

1981-03-01

428

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

429

Gas-Cooled Fast Breeder Reactor preliminary safety information document, Amendment 9. GCFR fuel cladding PC-5 (faulted) temperature limit  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning GCFR design and limiting faulted events; selection of PC-5 temperature limit; and verification test programs.

1980-02-01

430

Finding Answers: Information Needs of a Multidisciplinary Patient Care Team in an Emergency Department  

UK PubMed Central (United Kingdom)

Emergency Departments (ED) are fast-paced, information-intensive environments where patient care team members must address their information needs quickly and accurately. We conducted a qualitative...Full Text Available

2006-01-01

431

Fast, Scalable, Bayesian Spike Identification for Multi-Electrode Arrays  

UK PubMed Central (United Kingdom)

We present an algorithm to identify individual neural spikes observed on high-density multi-electrode arrays (MEAs). Our method can distinguish large numbers of distinct neural units, even when spikes...Full Text Available

432

Fast Flux Test Facility Reactor Vessel Removal Study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of removing the FFTF reactor vessel from its current location in the reactor cavity inside the Containment vessel to a transporter for relocation to a burial pit in the 200 Area.

2002-10-23

433

Drug Susceptibility Testing of Mycobacterium tuberculosis by a Nitrate Reductase Assay Applied Directly on Microscopy-Positive Sputum Samples  

UK PubMed Central (United Kingdom)

Current methods for drug susceptibility testing of Mycobacterium tuberculosis are either costly or slow. As the prevalence of multidrug-resistant strains increases, the need for fast,...Full Text Available

2005-07-01

434

Differential stain for mycobacteria that does not require heat.  

UK PubMed Central (United Kingdom)

A stain of 0.1% toluidine blue in a 1.0% aqueous solution of triethylene glycol followed by decolorization with acid-alcohol resulted in mycobacteria retaining the stain (violet), whereas non-acid-fast...Full Text Available

1981-01-01

435

DECOMP: A PDB decomposition tool on the web  

UK PubMed Central (United Kingdom)

The protein databank (PDB) contains high quality structural data for computational structural biology investigations. We have earlier described a fast tool (the decomp_pdb tool) for identifying and...Full Text Available

436

Comprehensive SNP-chip for retinitis pigmentosa-Leber congenital amaurosis diagnosis: new mutations and detection of mutational founder effects  

UK PubMed Central (United Kingdom)

Fast and efficient high-throughput techniques are essential for the molecular diagnosis of highly heterogeneous hereditary diseases, such as retinitis pigmentosa (RP). We had previously approached RP...Full Text Available

2010-01-01

437

Complete tree utilization of a fast growing species - eucalyptus hybrid  

Energy Technology Data Exchange (ETDEWEB)

Potential uses of foliage and bark wastes of E. ('Mysore') hybrid in southern India for the production of cineole and oxalic acid respectively are discussed. Only certain strains are cineole-rich and these are being successfully propagated vegetatively at the authors' laboratory.

1981-01-01

438

Comparison of McAuley/fasting insulin indices with ATP III clinical criteria for the diagnosis of insulin resistance in type 2 diabetes mellitus  

UK PubMed Central (United Kingdom)

Objective:To estimate the prevalence of insulin resistant syndrome (IRS) among newly diagnosed patients with type 2 diabetes and to test their validity against two indices...Full Text Available

2011-07-01

439

Cholinergic Interneurons Mediate Fast VGluT3-Dependent Glutamatergic Transmission in the Striatum  

UK PubMed Central (United Kingdom)

The neurotransmitter glutamate is released by excitatory projection neurons throughout the brain. However, non-glutamatergic cells, including cholinergic and monoaminergic neurons, express markers that...Full Text Available

440

Boundary value problem for an elliptic equation with rapidly oscillating coefficients in a rectangle  

British Library Electronic Table of Contents (United Kingdom)

An elliptic equation in a rectangle with coefficients depending on a fast variable and with its period being a small parameter is considered. An asymptotic expansion of the solution up to an arbitrary degree of the small parameter is constructed and substantiated by applying the two-scale expansion method.

2011-01-01

441

BFL: a node and edge betweenness based fast layout algorithm for large scale networks  

UK PubMed Central (United Kingdom)

BackgroundNetwork visualization would serve as a useful first step for analysis. However, current graph layout algorithms for biological pathways are insensitive to biologically...Full Text Available

442

Application of robotics in remote fuel fabrication operations  

International Nuclear Information System (INIS)

The Secure Automated Fabrication (SAF) line, an automated and remotely controlled manufacturing process, is scheduled for startup in 1987 and will produce mixed uranium/plutonium oxide fuel pins for the Fast Flux Test Facility (FFTF). The application of robotics in the fuel fabrication and supporting operations is described.

443

Analyzing the simplicial decomposition of spatial protein structures  

UK PubMed Central (United Kingdom)

BackgroundThe fast growing Protein Data Bank contains the three-dimensional description of more than 45000 protein- and nucleic-acid structures today. The large majority of the data...Full Text Available

444

An implicit curve-fitting method for fast calculation of thermal properties of pure and mixed refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Calculations of refrigerant thermal properties are desired to be very fast and stable in cases of simulation of refrigeration system, etc. The traditional method based on equation of state cannot meet such requirement because of unavoidable iterations in calculation. In this paper, a new calculation method for refrigerant thermal properties is presented. Low order implicit polynomial equations are got by using curve-fitting method at first, and then explicit formulae for calculating refrigerant thermal properties quickly are obtained by getting the analytical solution of these implicit equations. Explicit fast calculation formulae for thermal properties of R22 and R407C, covering the saturated temperature of -60{approx}80 {sup o}C and superheat of 0-65 {sup o}C, are presented as examples. The calculation speeds of the formulae of R22 are about 140 times faster than those of REFPROP 6.01 while the formulae of R407C are about 1000 times faster. ...

2005-09-01

445

Age at the onset of senescence in birds and mammals is predicted by early-life performance  

UK PubMed Central (United Kingdom)

Life-history theory predicts that traits involved in maturity, reproduction and survival correlate along a fast–slow continuum of life histories. Evolutionary theories and empirical results...Full Text Available

2010-09-22

446

A comparative analysis of phenylpropanoid metabolism, N utilization, and carbon partitioning in fast- and slow-growing Populus hybrid clones  

UK PubMed Central (United Kingdom)

The biosynthetic costs of phenylpropanoid-derived condensed tannins (CTs) and phenolic glycosides (PGs) are substantial. However, despite reports of negative correlations between leaf phenolic content...Full Text Available

2009-08-01

447

A TUNNEL DIODE UNIVIBRATOR AND PULSE HEIGHT DISCRIMINATOR  

Science.gov (United States)

A univibrator and a pulse height discriminator using tunnel diodes and backward diodes are described, along with their applications in pulse shaping and fast coincidence technique. The main advantages achieved are simplicity of design and speed. The characteristics of the two diodes are shown. (auth)

1961-03-01

448

Worker radiation doses in the United States at the dawn of the atomic era (1940--1960)  

Energy Technology Data Exchange (ETDEWEB)

Radiation doses to workers at the Manhattan Engineer District (MED) and US Atomic Energy Commission (AEC) sites due to external irradiation during 1940--1960 are reviewed. Categorized radiation dose data were available from AEC annual reports for some years. Annual individual radiation dose data for ten MED/AEC sites for all years were available from the US Department of Energy`s (DOE) Comprehensive Epidemiologic Data Resource (CEDR). These data are combined to produce an estimate of external collective dose equivalent to 172,000 person-rems (1720 person-Sv) for 1940--1960. During this period there were 41 overexposures, 19 criticality incidents, and 3 deaths due to acute radiation syndrome among several hundred thousand workers.

1994-06-01

449

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different ...

1984-01-01

450

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

451

Optimizing the conditioning regimen for allogeneic stem-cell transplantation in acute myeloid leukemia; dose intensity is still in need  

British Library Electronic Table of Contents (United Kingdom)

Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...

2011-01-01

452

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...

1996-12-31

453

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...

1996-11-10

454

On the applicability of the AAPM TG-60/TG-43 dose calculation formalism to intravascular line sources: Proposal for an adapted formalism  

International Nuclear Information System (INIS)

Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.

2001-04-01

455

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

456

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

457

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) ...

1988-01-01

458

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.

1987-01-01

459

United States Department of Energy breeder reactor staff training domestic program  

Energy Technology Data Exchange (ETDEWEB)

Two US DOE projects in the Pacific Northwest offer unique on-the-scene training opportunities at sodium-cooled fast-reactor plants: the Fast Flux Test Facility (FFTF) near Richland, Washington, which has operated successfully in a wide range of irradiation test programs since 1980; and the Experimental Breeder Reactor II (EBR-II) near Idaho Falls, Idaho, which has been in operation for approximately 20 years. Training programs have been especially designed to take advantage of this plant experience. Available courses are described.

1984-01-01

460

Risk-orientated analysis of the SNR 300. Technical report 1. Risk assessment of the fast breeder reactor. Risikoorientierte Analyse zum SNR 300. Fachbericht 1. Risikobewertung des Schnellen Brueters  

Energy Technology Data Exchange (ETDEWEB)

The study required by the West German Ministry of Research and Technology (RS 605) for the Committee on 'Future Nuclear Energy Policy' of the 9th German Parliament is concerned with the following main points: 1) Assessment of technical risks from the social aspect; 2) Discussion of terms and quantification of risks; 3) 'Engineering judgment' and 'questionable' methods in the Fast Breeder analysis of the Society for Reactor Safety (GRS); 4) Assessment criteria of potential damage.

1983-09-01

461

Production of polarized negative ion beams by collisional pumping  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1983-01-01

462

Production of polarized negative ion beams by ''collisional pumping''  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1984-03-01

463

Numerical prediction of flow field and particle trajectory in a hard disk drive  

Energy Technology Data Exchange (ETDEWEB)

A flow field and particle trajectory in a HDD (Hard Disk Drive) between two rotating disks in axisymmetric enclosures is investigated using CFD code FLUENT/UNS. The RNG k-{epsilon} model is used as a turbulent model. In this study, the flow field between two disks are symmetric, and the flow field near the enclosure is very complex. Cross stream vectors are shown both for blowing and no blowing from the hub. The larger a particle, the more fast the particle deposits at the walls. In the case of blowing from the hub, the more fast the particle deposits at the walls. (author). 9 refs., 12 figs., 1 tab.

1999-11-01

464

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

465

Modelling of Aquitaine II pipe whipping test with the EUROPLEXUS fast dynamics code  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a numerical simulation with the EUROPLEXUS fast dynamics software of a pipe whipping phenomenon occurring in the thermal hydraulic conditions of a loss of coolant accident in a PWR primary circuit. Different physical phenomena take place simultaneously during the rupture and the whipping of the pipe such as plasticity, contact, large displacements, two-phase flow regime and fluid structure interaction. Two kinds of numerical models - a simplified pipeline model and a mixed 1D/3D model - are considered and compared throughout modelling and computation. Numerical results are compared with experimental data belonging to the Aquitaine II test campaign.

2005-08-01

466

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

467

FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

468

FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

469

Effect of improved target designs on the "2"3"8Pu production at the Fast Flux Test Reactor  

International Nuclear Information System (INIS)

This paper present the results of a series of calculations made to determine the "2"3"8Pu production potential of several advanced target assembly designs in the Fast Flux Test Facility (FFTF). These calculations show that by using advanced target designs the intimately mix the "2"3"7Np target material with an yttrium hydride moderator, the FFTF has the potential of producing up to 30 kg of high-quality "2"3"8Pu per year.

1991-11-10

470

Analysis of JET LCHD/ICRH synergy experiments in terms of relativistic current drive theory  

Energy Technology Data Exchange (ETDEWEB)

The present analysis shows that the observed efficiency of current drive with synergy between LHCD and ICRH is in good agreement with the relativistic theory of Karney and Fisch for Landau damped waves. The predicted power absorption from the fast wave by the electron tail is within 30% of the measured value. In the presence of significant fast electron diffusion within a slowing down time it would be possible to produce central current drive using multiple ICRF resonances even when the LHCD deposition is at half radius, as in an ITER type device. (authors). 4 refs., 6 figs.

1994-07-01

471

Advanced Fuel Cycle Economic Sensitivity Analysis  

Energy Technology Data Exchange (ETDEWEB)

A fuel cycle economic analysis was performed on four fuel cycles to provide a baseline for initial cost comparison using the Gen IV Economic Modeling Work Group G4 ECON spreadsheet model, Decision Programming Language software, the 2006 Advanced Fuel Cycle Cost Basis report, industry cost data, international papers, the nuclear power related cost study from MIT, Harvard, and the University of Chicago. The analysis developed and compared the fuel cycle cost component of the total cost of energy for a wide range of fuel cycles including: once through, thermal with fast recycle, continuous fast recycle, and thermal recycle.

2006-12-01

472

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

473

A fast production scheduler for generation expansion planning in a hydro-thermal system  

Energy Technology Data Exchange (ETDEWEB)

A fast production scheduling algorithm suitable for generation expansion studies is described in this paper. It can handle several independent rivers, thermal plants, pumped storage plants, import, export, and internal non-firm markets. Inflows and load are deterministic and a one-reservoir limit is imposed on each river. The scheduling problem is formulated as a generalized network problem which is efficiently solved by an adaption of the simplex method. The algorithm is part of a program developed by Hydro-Quebec to conduct preliminary evaluations of alternative expansion plans. The program and the scheduling algorithm are presented.

1986-01-01

474

A fast production scheduler for generation expansion planning in a hydro-thermal system  

Energy Technology Data Exchange (ETDEWEB)

A fast production scheduling algorithm suitable for generation expansion studies is described in this paper. It can handle several independent rivers, thermal plants, pumped storage plants, import, export, and internal non-firm markets. Inflows and load are deterministic and a one-reservoir limit is imposed on each river. The scheduling problem is formulated as a generalized network problem which is efficiently solved by an adaption of the simplex method. The algorithm is part of a program developed by Hydro-Quebec to conduct preliminary evaluations of alternative expansion plans. The program and the scheduling algorithm are presented.

1987-02-01

475

Differential rod worth profile affected by axial blankets in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The central feature of the Fast Flux Test Facility (FFTF) is the fast test reactor (FTR), which is a liquid-sodium-cooled fast reactor providing high fast-neutron flux for irradiation testing of fuels and materials. The FTR also provides a means to develop breeder reactor core components and to gain reactor systems operating experience for future liquid-metal fast breeder reactors (LMFBRs). In the FTR core, there are 82 incore positions (within rows 1 through 6) available for driver fuel assemblies and/or test assemblies. In addition, there are three safety rods and six control rods located in rows 3 and 5, respectively, in the three symmetric core sectors. The FFTF has been successfully and continuously operated for more than 11 reactor cycles. For the first 8 cycles, the core loadings were composed of the mixed-oxide driver fuel assemblies and some test assemblies. These ...

1990-06-10

476

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single ...

2007-09-15

477

Enjebi Island dose assessment  

Energy Technology Data Exchange (ETDEWEB)

We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and /sup 137/Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body ...

1987-07-01

478

Dose proportionality and the effect of food on vildagliptin, a novel dipeptidyl peptidase IV inhibitor, in healthy volunteers.  

Science.gov (United States)

Vildagliptin is a potent and selective dipeptidyl peptidase IV inhibitor in development for the treatment of type 2 diabetes that improves glycemic control by enhancing alpha- and beta-cell responsiveness to glucose. Two open-label, single-dose, randomized, crossover studies in healthy subjects (ages 18-45 years) investigated the dose proportionality of vildagliptin pharmacokinetics (n = 20) and the effect of food (n = 24) on vildagliptin pharmacokinetics. There was a linear relationship (r(2) = 0.999) between vildagliptin doses of 25, 50, 100, and 200 mg and area under the plasma concentration-time curve from time zero to infinity (AUC(0-infinity)) and maximum plasma concentration (C(max)). Dose proportionality was assessed using a statistical power model [X = alpha x (dose)(beta)]. The 90% confidence intervals of the proportionality coefficient, beta, for AUC(0-infinity) ...

2007-07-26

479

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences ...

2011-01-01

480

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two ...

2008-10-01

481

Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2  

International Nuclear Information System (INIS)

Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per person for ...

1979-01-01

482

Development of a generic analysis code of dynamic compartment model for evaluation of doses in terrestrial biosphere  

International Nuclear Information System (INIS)

The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the evaluation of ...

1999-02-01

483

Calculating electron dose using a convolution/superposition method. 120  

International Nuclear Information System (INIS)

The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on paths from the interaction site to all the ...

484

AIDE: internal dosimetry software.  

Science.gov (United States)

AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides ...

2008-03-12

485

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

486

Is uniform target dose possible in IMRT plans in the head and neck?  

International Nuclear Information System (INIS)

Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...

2002-04-01

487

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...

488

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means ...

2007-05-01

489

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...

490

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

491

Manganese oxide nanowires, films, and membranes and methods of making  

Energy Technology Data Exchange (ETDEWEB)

Nanowires, films, and membranes comprising ordered porous manganese oxide-based octahedral molecular sieves, and methods of making, are disclosed. A single crystal ultra-long nanowire includes an ordered porous manganese oxide-based octahedral molecular sieve, and has an average length greater than about 10 micrometers and an average diameter of about 5 nanometers to about 100 nanometers. A film comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is stacked on a surface of a substrate, wherein the nanowires of each layer are substantially axially aligned. A free standing membrane comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is aggregately stacked, and wherein the nanowires of each layer are substantially axially aligned.

2008-10-21

492

Ionically conductive thin polymer films prepared by plasma polymerization. Pt. 7. Preparation and characterization of solid polymer electrolyte having fixed carboxylic acid groups with single mobile species  

Energy Technology Data Exchange (ETDEWEB)

Ultra-thin, uniform, pinhole-free solid polymer electrolyte films having a fixed carboxylic ester group of approximately 1 {mu}m thickness were prepared by polymerization of methyl acrylate and tris(2-methoxyethoxy)vinylsilane in a glow discharge plasma. The carboxylic ester group of the plasma polymer were transformed to lithium carboxylate groups by treatment with lithium iodide. This process give a single lithium ion conductive film. These solid polymer electrolyte films showed ionic conductivities of the order of 10{sup -8} S cm{sup -1} (10{sup 4} {omega} cm{sup 2} resistance per unit area) at room temperature. (orig.).

1990-08-01

493

Influence of Population III stars on cosmic chemical evolution  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT New observations from the Hubble Ultra Deep Field suggest that the star formation rate at Formula Not Shown drops off faster than previously thought. Using a newly determined star formation rate for the normal mode of Population II/I (PopII/I) stars, including this new constraint, we compute the Thomson scattering optical depth and find a result that is marginally consistent with Wilkinson Microwave Anisotropy Probe 5 results. We also reconsider the role of Population III (PopIII) stars in light of cosmological and stellar evolution constraints. While this input may be needed for reionization, we show that it is essential in order to account for cosmic chemical evolution in the early universe. We investigate the consequences of PopIII stars on the local metallicity distribution fu...

2009-01-01

494

Hot dip galvanised dual phase steels for automotive applications  

Energy Technology Data Exchange (ETDEWEB)

The automotive industry desires to optimize safety and lightweight construction for the production of cars and trucks. The resulting task for steel suppliers is to make steel grades available that can fulfil these requirements. Different projects have shown optimistic outlooks for optimization of safety and reduction of the weight of automobile bodies by using different high strength and ultra high strength steels. In the last group the dual phase steels play the lead. In recent years different steel grades have been developed and optimized for these applications. On one hand developing the mechanical properties as well as joining and forming of dual phase steels is one of the first steps. On the other hand different coated surfaces for various applications of dual phase steels is another step. Starting with characteristic production conditions for cold rolled hot dip galvanised dual phase steels, the mechanical properties for joining and forming will be deduced ...

2005-07-01

495

High-temperature property data: Ferrous alloys  

Energy Technology Data Exchange (ETDEWEB)

In this book over 250 alloys are organized by AISI number into 10 major sections: Irons, Carbon Steels, Alloy Steels, Low Alloy Constructional Steels, Ultra High Strength Steels, Tool Steels, Maraging Steels, Wrought Stainless Steels, Heat Resistnat Casting Alloys, and Iron Based Rought Superalloys. Each alloy record lists the designation, specifications, UNS number, composition, product forms and a comment on the high-temperature properties and applications. Referenced data is then given for physical properties such as density, specific heat, thermal conductivity, thermal expansion, electrical conductivity, Poisson's ratio, moduli of elasticity and rigidity, etc. Mechanical properties follow, and include tensile properties, shearing and bearing properties, impact properties, creep, stress rupture and stress relaxation and fatigue properties. The last part of the alloy record gives other effects of temperature, such as hot hardness, corrosion, and growth.

1987-01-01

496

High-Throughput Screening of Drugs of Abuse in Urine by Supported Liquid?Liquid Extraction and UHPLC Coupled to Tandem MS  

British Library Electronic Table of Contents (United Kingdom)

A qualitative method, involving supported liquid?liquid extraction (SLE) and ultra high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS?MS), was developed for the rapid tentative identification of various drugs of abuse in urine. In this study, 28 drugs and metabolites were covered by the screening procedure. Before analysis, urine samples were extracted by SLE and good extraction recoveries were obtained for most investigated compounds. The UHPLC strategy was then selected for the rapid separation of amphetamines, cocaine, opiates and related compounds in urine. Using columns packed with sub-2??m particles, analysis time was reduced down to 2?min, while maintaining acceptable performance. Finally, the detection was by tandem MS operating in the single reaction...

2009-01-01

497

Empirical regularities of order placement in the Chinese stock market  

CERN Document Server

Using ultra-high-frequency data extracted from the order flows of 23 stocks traded on the Shenzhen Stock Exchange, we study the empirical regularities of order placement in the opening call auction, cool period and continuous auction. The distributions of relative logarithmic prices against reference prices in the three time periods are qualitatively the same with quantitative discrepancies. The order placement behavior is asymmetric between buyers and sellers and between the inside-the-book orders and outside-the-book orders. In addition, the conditional distributions of relative prices in the continuous auction are independent of the bid-ask spread and volatility. These findings are crucial to build an empirical behavioral microscopic model based on order flows for Chinese stocks.

2007-01-01

498

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)