WorldWideScience
1

Comparison of the UHF Follow-on and MILSTAR Satellite Communication Systems.  

Science.gov (United States)

The author compares the UHF Follow-on and MILSTAR satellite communication systems. The comparison uses an analytical hierarchy process. Although the two systems have been tasked with different missions, a comparison of cost, capability, and orbit is condu...

1991-01-01

2

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...

2003-03-04

3

Experimental measurement of low-energy antiprotons in the cosmic radiation  

Energy Technology Data Exchange (ETDEWEB)

Researchers report results from the Low Energy Antiproton Experiment (LEAP), a balloon-borne instrument which was flown in August, 1987. They found a value of 4.2 by 10-6 for the antiproton to proton ratio in the energy range from 120 MeV to 600 MeV at the top of the atmosphere. In particular, this experiment places an upper limit on the flux almost an order of magnitude below the reported flux of Buffington et al. This upper limit allows us to place significant constraints on both the primordial black hole and weakly interacting Majorana Fermion hypothesis, as well as on the low energy processes in more conventional models of galactic cosmic ray antiproton production.

1990-01-01

4

Temperature stabilization, ocean heat uptake and radiative forcing overshoot profiles  

British Library Electronic Table of Contents (United Kingdom)

Political leaders in numerous nations argue for an upper limit of the global average surface temperature of 2 K above the pre-industrial level, in order to attempt to avoid the most serious impacts of climate change. This paper analyzes what this limit implies in terms of radiative forcing, emissions pathways and abatement costs, for a range of assumptions on rate of ocean heat uptake and climate sensitivity. The primary aim is to analyze the importance of ocean heat uptake for radiative forcing pathways that temporarily overshoot the long-run stabilization forcing, yet keep the temperature increase at or below the 2 K limit. In order to generate such pathways, an integrated climate-economy model, MiMiC, is used, in which the emissions pathways generated represent the least-cost solution o...

2011-01-01

5

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

6

EVIDENCE FOR EVOLUTION AMONG PRIMORDIAL DISKS IN THE 5 Myr OLD UPPER SCORPIUS OB ASSOCIATION  

International Nuclear Information System (INIS)

Moderate-resolution, near-infrared spectra between 0.8 and 5.2 #mu#m were obtained for 12 late-type (K0-M3) disk-bearing members of the #approx#5 Myr old Upper Scorpius OB association using SpeX on the NASA Infrared Telescope Facility. For most sources, continuum excess emission first becomes apparent between #approx#2.2 and 4.5 #mu#m and is consistent with that produced by single-temperature blackbodies having characteristic temperatures ranging from #approx#500 to 1300 K. The near-infrared spectra for 5 of 12 Upper Scorpius sources exhibit Pa#gamma#, Pa#beta#, and Br#gamma# emission, indicators of disk accretion. Using a correlation between Pa#beta# and Br#gamma# emission line luminosity and accretion luminosity, mass accretion rates ( M-dot ) are derived for these sources that range from M-dot = 3.5x10"-"1"0 to 1.5 x 10"-"8 M_s_u_n yr"-"1. Merging the SpeX observations with Spitzer Space Telescope ...

2010-11-01

7

Magnetospheric Emissions from the Planet Orbiting tau Boo: A Multi-Epoch Search  

CERN Document Server

All of the solar system gas giants produce electron cyclotron masers, driven by the solar wind impinging on their magnetospheres. Extrapolating to the planet orbiting tau Boo, various authors have predicted that it may be within the detection limits of the 4-meter wavelength (74 MHz) system on the Very Large Array. This paper reports three epochs of observations of tau Boo. In no epoch do we detect the planet; various means of determining the upper limit to the emission yield single-epoch limits ranging from 135 to 300 mJy. We develop a likelihood method for multi-epoch observations and use it to constrain various radiation properties of the planet. Assuming that the planet does radiate at our observation wavelength, its typical luminosity must be less than about 10^{16} W, unless its radiation is highly beamed into a solid angle Omega << 1 sr. While within the ...

2007-01-01

8

Neutrino bilarge mixing and flavor physics in the flipped SU(5) model  

International Nuclear Information System (INIS)

We have constructed a specific supersymmetric flipped SU(5) GUT model in which bilarge neutrino mixing is incorporated. Because the up-type and down-type quarks in the model are flipped in the representations ten and five with respect to the usual SU(5), the radiatively generated flavor mixing in squark mass matrices due to the large neutrino mixing has a pattern different from those in the conventional SU(5) and SO(10) supersymmetric GUTs. This leads to phenomenological consequences quite different from SU(5) or SO(10) supersymmetric GUT models. That is, it has almost no impact on B physics. On the contrary, the model has effects in top and charm physics as well as lepton physics. In particular, it gives promising prediction on the mass difference, #DELTA#M_D, of the D-D-bar mixing which for some ranges of the parameter space with large tan#beta# can be at the order of 10"9 #Planck constant# s"-"1, one order of magnitude smaller than the ...

2003-11-24

9

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

10

Some properties of low-mass stellar models with chemically inhomogeneous neutral-stability zones  

Energy Technology Data Exchange (ETDEWEB)

Several low-mass models with an inhomogeneous radiative core and a convective envelope are investigated, the entire core or its upper portion being treated as a zone of neutral stability. Mixing by convective overshoot will then give rise to unstable structure.

1983-03-01

11

A comparison of the UHF Follow-On and MILSTAR satellite communication systems  

Science.gov (United States)

The author compares the UHF Follow-On and MILSTAR satellite communication systems. The comparison uses an analytical hierarchy process. Although the two systems have been tasked with different missions, a comparison of cost, capability, and orbit is conducted. UFO provides many of the same capabilities as MILSTAR, but on a smaller scale. Since UFO is also a new space system acquisition, it is used to compare dollars spent to field a viable communication system. A review of frequency bands, losses, and problems is conducted to establish the relationship. Cost data is provided to establish the major difference in the systems. While MILSTAR does possess more total capability than UFO, it is 10 times more costly. Additionally, UFO is a satellite that will evolve with new technology while MILSTAR is built to full capability immediately. In the author's opinion, the incremental performance of MILSTAR does not justify its incremental cost.

1991-09-01

12

Study of e{sup +}e{sup -}{yields}pp using initial state radiation with BABAR  

Science.gov (United States)

The e{sup +}e{sup -}{yields}pp cross section is determined over a range of pp masses, from threshold to 4.5 GeV/c{sup 2}, by studying the e{sup +}e{sup -}{yields}pp{gamma} process. The data set corresponds to an integrated luminosity of 232 fb{sup -1}, collected with the BABAR detector at the PEP-II storage ring, at an e{sup +}e{sup -} center-of-mass energy of 10.6 GeV. The mass dependence of the ratio of electric and magnetic form factors, G{sub E}/G{sub M}, is measured for pp masses below 3 GeV/c{sup 2}; its value is found to be significantly larger than 1 for masses up to 2.2 GeV/c{sup 2}. We also measure J/{psi}{yields}pp and {psi}(2S){yields}pp branching fractions and set an upper limit on Y(4260){yields}pp production and decay.

2006-01-01

13

Officer in Tactical Command and Tactical Data Information Exchange Systems (OTCIXS/TADIXS) and the Transition to the Military Strategic and Tactical Relay System (MILSTAR).  

Science.gov (United States)

The purpose of this thesis is to explore possible difficulties and their solutions in transitioning the OTCIXS/TADIXS subsystems from the present Navy UHF Fleetwide Satellite System to the EHF/SHF MILSTAR System. The research provides a description of the...

1987-01-01

14

Cutaneous and subcutaneous Ewing's sarcoma: an indolent disease  

International Nuclear Information System (INIS)

Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy ...

2000-01-15

15

Chinese Journal of Lasers (Selected Articles)  

Science.gov (United States)

... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...

1991-12-10

16

Two- and three-phonon states in "8"8Sr  

International Nuclear Information System (INIS)

... de-excitation excited states gamma radiation inelastic scattering mev range

17

The structure of the 4.743 MeV state in "8"8Sr  

International Nuclear Information System (INIS)

... states gamma radiation mev range 01-10 photonuclear reactions polarization

18

Lifetime of 2.734 mev Sr"8"8 level  

International Nuclear Information System (INIS)

... range 01-10 nuclei photons radiation sources recoils resonance scattering

20

Biological effects of electromagnetic radiation in the microwave range  

Energy Technology Data Exchange (ETDEWEB)

The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave ...

1980-01-01

21

Dynamics of spontaneous radiation of atoms scattered by a resonance standing light wave  

International Nuclear Information System (INIS)

The scattering of atoms by a resonance standing light wave is considered under conditions when the lower of two resonance levels is metastable, while the upper level rapidly decays due to mainly spontaneous radiative transitions to the nonresonance levels of an atom. The diffraction scattering regime is studied, when the Rabi frequency is sufficiently high and many diffraction maxima are formed due to scattering. The dynamics of spontaneous radiation of an atom is investigated. It is shown that scattering slows down substantially the radiative decay of the atom. The regions and characteristics of the power and exponential decay are determined. The adiabatic and nonadiabatic scattering regimes are studied. It is shown that the wave packets of atoms in the metastable and resonance excited states narrow down during scattering. A limiting (minimal) size of the wave packets is found, which is achieved upon ...

2003-09-01

22

Microwaves (including RADAR) and radiation protection  

Energy Technology Data Exchange (ETDEWEB)

The Commission of the European Communities has submitted a directive for the protection against microwaves. According to this directive, exposures above the upper limit established for the protection of individuals and the general population are permissible only if the respective individuals are required to submit to occupational medical control. An introductory overview is presented giving information on microwaves, applied techniques and available protective means.

1981-02-01

23

Commentary  

International Nuclear Information System (INIS)

1. It is not possible to give a threshold value for the dose - nor for genetic neither for somatic late effects. 2. The linear dose-effect exprapolation is not conservative in the sense of 'fying on the safe side'. 3. There has been found no relative reduction of the effects at chronic radiation exposure in man. 4 The numbers given by authorities and utilities for damage rates per rem received, that are called upper limits, are by far too low. (orig./HP).

1980-02-01

24

The electric Earth: Cosmic influences on the atmosphere  

DEFF Research Database (Denmark)

The universe is full of exotic particles and waves. Some, such as neutrinos, pass through our neighbourhood unnoticed; others, such as extreme uv radiation, are absorbed by the upper atmosphere before they are able to do too much damage. For a long time, any systematic attempt to understand how our weather can be affected by extra-terrestrial sources other than solar visible and infrared radiation has been a lively and often controversial diversion from mainstream research. But recent scientific and technological breakthroughs and concern over long-term climate change have brought this subject into the spotlight.

2002-01-01

25

Spontaneous radiation and lamb shift in three-dimensional photonic crystals  

Science.gov (United States)

Spontaneous emission in photonic crystals with anisotropic three-dimensional dispersion relation is studied. If the upper level is below a characteristic frequency omega(1), or above omega(2), or between omega(1) and omega(2), the radiation is a localized field with a frequency in the band gap, or a propagating field with a frquency in the band, or a diffusion field, respectively. An analytical expression for the Lamb shift is obtained. The Lamb shift for the current case is small compared to that in an ordinary vacuum or in one- or two-dimensional photonic crystals due to lower density of states. PMID:11017227

2000-03-01

26

Estimated values of the genetic and somatic radiation exposure of the Bulgarian population in 1976  

International Nuclear Information System (INIS)

The genetically and leukemia-significant doses (GSD and LSD) were calculated from the average gonad and bone marrow doses caused by the most frequently applied radiopharmaceuticals in Bulgaria in 1976. Because of the lack of information about the age groups of the patients examined assumptions have been made which led to estimated values of 0.97 mrad for GSD and 2.0 mrad for LSD which must be considered as the upper limit of the real GSD and LSD. The influence of the different radiopharmaceuticals on the average radiation exposure of the population is discussed. (author).

1976-01-01

27
28

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...

2008-05-01

29

Study of implantation damage in germanium formed using Ga"+ FIB  

International Nuclear Information System (INIS)

Full text: It is known that the ion implantation of germanium single crystals at room temperature results in drastic alteration of the germanium surface and the formation of cellular relief. Voids were found into the near-surface damage layer. The intersection of these voids with the germanium surface, as result of sputter etching, forms cellular relief. However, exact mechanism responsible for formation of the voids is not known. A 10 and 30 keV Ga"+ irradiation of Ge #left brace#100#right brace# crystal at room temperature was carried out using a focused ion beam (FIB) system with a dose in the range 0.5x10"1"2 to 1.5x10"1"4 ion/cm"2. The topology of the modified germanium surface and the structure of the radiation damage was studied using imaging facilities of the FIB systems and transmission electron microscopy. The strong cellular structure of Ge was observed after an ion dose of 3x10"1"3 ion/cm"2. High-resolution TEM showed a complex ...

30

Spatially resolved methane band photometry of Jupiter. III - Cloud vertical structures for several axisymmetric bands and the Great Red Spot  

Energy Technology Data Exchange (ETDEWEB)

The paper presents cloud structure models for Jupiter's Great Red Spot, Equatorial and North Tropical Zones, North and South Temperate Zones, and North and South Polar Regions. The models are based on images of Jupiter in three methane bands and nearby continuum radiative transfer calculations include multiple scattering and absorption from three aerosol layers. The model results include the transition in the upper-cloud altitude to 3 km lower altitude from the tropical zones to temperate zones and polar regions, a N/S asymmetry in cloud thickness in the tropical and temperature zones, and the presence of aerosols up to about 0.3 bar in the Great Red Spot and Equatorial Zone. It is concluded that polarization data are sensitive to aerosols in and above the upper cloud layer but insensitive to deeper cloud structure.

1980-02-01

31

Flashlamp radiation recycling for enhanced pumping efficiency and reduced thermal load  

Energy Technology Data Exchange (ETDEWEB)

A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.

1989-01-01

32

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

33

Radiation hardening in neutron-irradiated polycrystalline copper: Barrier strength of defect clusters  

International Nuclear Information System (INIS)

Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).

1989-12-04

34

Ultraviolet radiation in Finland  

Energy Technology Data Exchange (ETDEWEB)

Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities ...

1996-12-31

35

On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta  

International Nuclear Information System (INIS)

... gamma radiation l conversion m conversion mev range 10-100 mixing ratio

1987-04-14

36

Studies on the superconducting properties of A-15 type intermetallic compounds  

International Nuclear Information System (INIS)

The influence of 3d-transition metal impurities on the superconducting properties of the A-15 compounds V_3Si and V_3Ga have been investigated. In the case of V_3Si, the Fe impurities replacing V were found to have a local moment. A compensation effect was found in this case, resulting in a 20KOe increase in the upper critical field at dilute concentrations of Fe. It was demonstrated that long range order V_3Ga possessed higher transition temperature and upper critical field than found hitherto. Investigations on Nb_3Ge/sub 1-x/Ga/sub x/ films obtained by chemical vapor deposition has clearly shown the relation between the transition temperature and structural characteristics. The influence of generalized defects on the superconducting properties in A-15 type Nb_3X compounds has been discussed.

37

An Upper Limit on the Albedo of HD 209458b: Direct Imaging Photometry with the MOST Satellite  

CERN Document Server

We present space-based photometry of the transiting exoplanetary system HD 209458 obtained with the MOST (Microvariablity and Oscillations of STars) satellite, spanning 14 days and covering 4 transits and 4 secondary eclipses. The HD 209458 photometry was obtained in MOST's lower-precision Direct Imaging mode, which is used for targets in the brightness range $6.5 < V < 13$. We describe the photometric reduction techniques for this mode of observing, in particular the corrections for stray Earthshine. We do not detect the secondary eclipse in the MOST data, to a limit in depth of 0.053 mmag (1 \\sigma). We set a 1 \\sigma upper limit on the planet-star flux ratio of 4.88 x 10^-5 corresponding to a geometric albedo upper limit in the MOST bandpass (400 to 700 nm) of 0.25. The corresponding numbers at the 3 \\sigma level are 1.34 x 10^-4 and 0.68 respectively. HD 209458b is half as bright as Jupiter in the MOST ...

2006-01-01

38

Sphincter-saving procedure for radiation-injuried rectum. A report of four cases with special reference to pull-through procedure  

Energy Technology Data Exchange (ETDEWEB)

Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus ...

1982-09-01

39

Solar aircraft  

Energy Technology Data Exchange (ETDEWEB)

This invention is concerned with a solar energy system for propelling aircraft. Obtained are forces for aerodynamic lift and impetus. The lifted body had a transparent upper surface for the sun light, but black or reflecting for IR-radiation and high thermal insulation properties. Inside of the lifted body, the air temperature increases and is lifted by convection influence. The air resistance of this body is low in horizontal direction and higher in vertical position. The payload could be shifted, so that the positive or negative angle of the whole body can be selected. By this principal it is possible to transform the static lifting force in a dynamic impetus.

1981-07-30

40

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

41

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

42

Drug eruptions presenting at sites of prior radiation damage (sunlight and electron beam)  

Energy Technology Data Exchange (ETDEWEB)

Two patients are described in whom sunburn and electron beam radiodermatitis, respectively, were critical determinants in localizing the initial presentation of drug eruptions. In the first instance, a severe sunburn of the back and thighs was followed 7 months later by the appearance of a toxic epidermal necrolysis drug reaction to trimethoprim-sulfamethoxazole in the exact sites of the previous bullous sunburn reaction. In the second patient, a radiodermatitis of the left upper arm due to electron beam therapy for metastatic breast cancer was followed 7 weeks later by a codeine drug reaction confined to the area of the radiodermatitis. In both instances, oral rechallenge with the offending drug reproduced the eruption.

1984-07-01

43

Solar unit  

Energy Technology Data Exchange (ETDEWEB)

A solar unit is described which contains a cavity radiation receiver, parabolic-cylindrical concentrator, and reflector arranged between the radiation receiver and the concentrator symmetrically in relation to the optical plane of the latter. In order to expand the range of use, it contains a pair of flat mirrors with 2 working surfaces installed at an angle and symmetrically to the optical plane of the parabolic cylindrical concentrator between them and the reflector, while the latter is made in the form of 2 flat mirrors installed at an angle on the cavity radiation receiver.

1982-01-01

44

Nuclear Raman processes and the development of gamma-ray lasers  

International Nuclear Information System (INIS)

This review briefly describes current efforts to develop superradiant sources of coherent radiation for the sub-nanometer range of wavelenghs, using nuclear rather than the atomic or molecular transitions that are stimulated in existing lasers. First the radiative (including Raman) interactions of nuclei with those of atoms and molecules are compared; then the present status of research on the fundamental problems involved in stimulating nuclear gamma radiation is described. (author). 20 refs.; 2 figs.

45

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal ...

2008-11-19

46

Closed-form solutions for some metric perturbations from a closed Friedmann model and the distortion of the universe  

International Nuclear Information System (INIS)

We consider perturbations of a particular type (homogeneous of Bianchi type IX) from a closed Friedmann-Robertson-Walker model. By considering a perfect fluid, we obtain closed-form solutions for the perturbations in three interesting cases: stiff matter, radiation, and dust. As a cosmological application, we obtain an upper limit on the relative shear, (sigma/theta)_0 < b/sub 0exp/, if the microwave background radiation was last scattered at a mean red-shift element of [7,10"3] and the density parameter is #OMEGA# element of (1,10), where b/sub 0exp/ is the relative root-mean-square deviation of the temperature over the whole sky.

47

Television interference and acoustic emissions associated with the operation of the Darrieus VAWT  

Science.gov (United States)

Field surveys were conducted to assess the community annoyance potential from electromagnetic interference to television reception (TVI) and acoustic emissions associated with the operation of a Darrieus-type, vertical axis wind turbine (VAWT). The type and extent of interference to nearby television reception was evaluated using a 17 meter VAWT. A series of measurements of observed interference levels were made at a number of sites in the turbine vicinity employing the locally available VHF and UHF television signals as sources. A simple theoretical model was developed for analyzing the TVI produced by the Darrieus turbine. Using this model in conjunction with the field measurements, it was found the Darrieus/VAWT produces the same amount of interference on the lower VHF channels as a horizontal axis turbine with a comparably sized blade scattering area, but less on all other channels.

1981-01-01

48

Ionizing Radiation and Life  

British Library Electronic Table of Contents (United Kingdom)

Abstract Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from th...

2011-01-01

49

Free electron radiation and the Beijing Free Electron Laser  

International Nuclear Information System (INIS)

Various particle-photon or beam-wave interactions are discussed. To be of use as intense radiation sources, it is necessary that these interactions produce coherent radiation. The free electron laser (FEL), developed on the basis of undulator radiation, is the result of many years of interaction between physics and technology. It has many features, such as continuous tunability over a wide wavelength range, excellent optical quality, high power and short pulse capability, and thus has many potential applications. FEL development in China and abroad are mentioned and the Beijing FEL presented to illustrate the physics and technology involved in an FEL project.

50

Searching for modifications to the exponential radioactive decay law with the Cassini spacecraft  

CERN Document Server

Data from the power output of the radioisotope thermoelectric generators aboard the Cassini spacecraft are used to test the conjecture that small deviations observed in terrestrial measurements of the exponential radioactive decay law are correlated with the Earth-Sun distance. No significant deviations from exponential decay are observed over a range of 0.7 - 1.6 A.U. A 90% Cl upper limit of 0.84 x 10^-4 is set on a term in the decay rate of Pu-238 proportional to 1/R^2 and 0.99 x 10^-4 for a term proportional to 1/R.

2008-01-01

51

A regional evaluation of coal quality in the northern foothills/mountains region of Alberta  

Energy Technology Data Exchange (ETDEWEB)

The report is the second of three describing the geology of coal quality variations in the foothills and mountains region of Alberta. The Lower Cretaceous Luscar Group, Lower Paleocene Coalspur Formation, and the Upper Paleocene Paskapoo Formation (Obed-Marsh coal zone, which is classified as a foothills deposit) are evaluated. Data on proximate and ultimate analysis variables, calorific analysis, vitrinite reflectance, maceral analyses, and coal quality relationships are presented. The coals range from low volatile bituminous to subbituminous A. Regional and local in seam coal quality variations are examined. 49 refs., 39 figs., 6 tabs.

1989-12-31

52

Regulation of the Low Dose Radiation Paracrine-Specific Anchorage-Independent Growth Response by Annexin A2  

Energy Technology Data Exchange (ETDEWEB)

ABSTRACT-Here we identify release of annexin A2 into the culture medium in response to low dose X-ray radiation exposure and establish functional linkages to an established paracrine factor-mediated anchorage-independent growth response. Using a standard bicameral coculture model, we observe that annexin A2 levels associated with non-irradiated neighboring cells seeded in the lower chamber (annexin A2 silenced [shRNA] JB6 cells) are increased upon coculture with irradiated (10-50 cGy) JB6 cells seeded in the upper chamber, relative to coculture with sham exposed JB6 cells seeded in the upper chamber, suggesting that annexin A2 released into the medium is capable of communicating in a paracrine fashion. Using a previously established coculture model, we observed that the paracrine factor-mediated anchorage-independent growth response to low dose X-ray radiation is markedly reduced when irradiated annexin ...

2009-07-13

53

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...

2008-05-01

54

Effect of decrease of molybdenum radiation hardening at high energy proton irradiation  

International Nuclear Information System (INIS)

By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.

1990-05-22

55

Radiation hardening revisited: role of intracascade clustering  

International Nuclear Information System (INIS)

Experimental observations related to the initiation of plastic deformation in metals and alloys irradiated with fission neutrons have been analyzed. The experimental results, showing irradiation-induced increase in the upper yield stress followed by a yield drop and plastic instability, cannot be explained in terms of conventional dispersed-barrier hardening because (a) the grown-in dislocations are not free, and (b) irradiation-induced defect clusters are not rigid indestructible Orowan obstacles. A new model called 'cascade-induced source hardening' is presented where glissile loops produced directly in cascades are envisaged to decorate the grown-in dislocations so that they cannot act as dislocation sources. The upper yield stress is related to the breakaway stress which is necessary to pull the dislocation away from the clusters/loops decorating it. The magnitude of the breakaway stress has been estimated and is found to be in good ...

56

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

57

Neutron induced disorder in superconducting A-15 compounds  

International Nuclear Information System (INIS)

The effect of high energy neutron (E greater than 1 MeV) irradiation at 60"0C on the superconducting critical temperature, T/sub c/, the upper critical field, H/sub c2/, the lattice parameter, a_0, and the degree of Long Range Order has been measured for Nb and V based A-15 superconducting compounds. Large reductions in T/sub c/"0 and H/sub c2/ are observed for fluences up to 5.0 x 10"1"9 n/cm"2. For Nb_3Al, a_0 increases and the degree of Long Range Order is significantly reduced as T/sub c/ is depressed. Results are discussed in terms of atomic ordering in the A-15 structure.

1974-09-30

58

Measurement of the antiproton/proton ratio in the few-TeV energy range with ARGO-YBJ  

CERN Document Server

Cosmic ray antiprotons provide an important probe for the study of cosmic ray propagation in the interstellar space and to investigate the existence of Galactic dark matter. The ARGO-YBJ experiment is observing the Moon shadow with high statistical significance at an energy threshold of a few hundred GeV. Using all the data collected until November 2009, we set two upper limits on the antip/p flux ratio: 5% at an energy of 1.4 TeV and 6% at 5 TeV with a confidence level of 90%. In the few-TeV range the ARGO-YBJ results are the lowest available, useful to constrain models for antiproton production in antimatter domains.

2010-01-01

59

New oil exploration play in Florida: The upper Fredericksberg Dollar Bay Formation  

Energy Technology Data Exchange (ETDEWEB)

The Fredericksberg of South Florida may have a great oil potential that has been overlooked as a primary target in past decades. Previous exploration in the area has targeted the Lower Cretaceous oil-producing Sunniland Formation lower in the stratigraphic section. The Fredericksberg Dollar Bay Formation has hydrocarbon shows in many wells occurring in limestone biohermal deposits as well as in an upper dolomitic section. The Dollar Bay Formation is part of the Big Cypress Group of the Comanchean Series of the Lower Cretaceous. The Lower Cretaceous lithology is composed of evaporitic-carbonate cycles consisting of anhydrites, dolomites, and limestones. There are also present some calcareous shales, mudstones, salt, lignitic material, and carbonaceous material, especially in the anhydrite and limestone intervals. The limestones are usually micritic, chalky, calcarenitic, sometimes argillaceous, containing skeletal particles of gastropods, pelecypods, ostracods, ...

1990-09-01

60

Limiting values of radionuclide intake and air concentration and dose conversion factors for inhalation, submersion, and ingestion: Federal guidance report No. 11  

Energy Technology Data Exchange (ETDEWEB)

Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived guides that are consistent with current ...

1988-09-01

61

Application of multi-stage, multi-disk type downhole seismic source; Tadanshiki taso enbangata koseinai shingen no tekiyosei  

Energy Technology Data Exchange (ETDEWEB)

A multi-stage, multi-disk type seismic source was developed as a downhole seismic source. The seismic source is an improved version of the downhole seismic source of a system in which an elastic wave is generated by a weight accelerated by restitutive force of a spring striking the upper part of a laminated structure consisted of metal disks and elastic bodies installed in water in a well. Enhancing the vibration exciting efficiency requires impedance radiated from the disks to be increased. The multi-disk structure was adopted because of restrictions on the disk area under the limiting condition of being inside the well. Further limitation has still existed, which led to finally structuring the multi-disk type to a multi-stage construction to increase the radiated impedance. In order to increase average velocity on the radiation surface, mass relationship between the hammer and the anvil was sought so ...

1997-05-27

62

On Sensitivity of Spectral Radiative Fluxes to Atmospheric Water Vapor in the 940 nm Region (Numerical Simulation)  

Energy Technology Data Exchange (ETDEWEB)

Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...

2005-03-18

63

Measurements of x-ray radiation dose levels during radiological examination in Jos university teaching hospital and Plateau state specialist hospital  

International Nuclear Information System (INIS)

In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.

2008-10-15

64

Health risks arising from ionizing radiation and chemical pollutants  

International Nuclear Information System (INIS)

In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified ...

1979-10-03

65

Seasonal and Annual Variation in Activity in Wild Male Meadow Voles (Microtus Pennsylvanicus).  

Science.gov (United States)

Project ZEUS was designed to characterize the effects of long-term gamma irradiation on free-ranging meadow voles, and to determine the lowest level of radiation at which biological effects are discernible in the population. Behavioural tests are consider...

1980-01-01

66

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

67

Uranium studies in the Tims Branch and Steed Pond system  

Energy Technology Data Exchange (ETDEWEB)

During the weekend of September 2--3, 1984, a part of the wooden spillway for Steed Pond gave way and the pond slowly drained. Consideration is being given to leaving Steed Pond dry. Steed Pond has accumulated some of the uranium discharged from 300 Area operations and past surveys have shown that the uranium concentration in the sediments ranges between 20 and 531 pCi/gm. The recently completed aerial survey of the exposed area of Steed Pond showed that the uranium was widely spread in the sediments of Steed Pond. Until ground cover is established over the exposed pond sediments, they will be subject to erosion. As much as 90 tons of sediment could be eroded from the exposed sediments in Steed Pond the first year, but the erosion could be reduced to 5--15 tons by establishing a ground cover such as rye grass. Only about 40% of the eroded sediment would be delivered to Upper Three Runs Creek, because most of the eroded sediment deposited before ...

1984-11-01

68

Spontaneous radiation decay of weakly bound system in externa field  

International Nuclear Information System (INIS)

A new channel of nonlinear ionization of quantum system in a strong laser field is discussed. The probability of spontaneous radiation decay from the ground state in a short-range potential to the final Volkov wave function, is calculated by the first order of the perturbation theory. It is shown that this process at high intensities of the laser field will be comparable with the high harmonic generation. (orig.)

2001-02-01

69

Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children  

Energy Technology Data Exchange (ETDEWEB)

During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session ...

1996-03-01

70

Proton beam therapy for cancer in deep-seated organs  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.

1988-10-01

71

Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses  

Energy Technology Data Exchange (ETDEWEB)

Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.

2007-11-15

72

Radiation hardening of semiconductor parts  

International Nuclear Information System (INIS)

This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.

73

Upper bound for a three-photon excitation cross section in atomic argon in the ultraviolet regime  

International Nuclear Information System (INIS)

A scheme of evaluating a generalized three-photon excitation cross section #sigma#/sub (3)/ in neutral atomic argon at 3144.67 A is outlined. Three photons at this wavelength can excite the neutral argon atoms from the ground 3p"6 "1S_0 state to the 3p"54s'[1/2]_1"0 state. The fourth photon will ionize the argon atoms. Assuming linear polarization of the incident laser radiation, contributions from several channels in various energy-level schemes are summed in the evaluation of the transition probability. For a laser linewidth of #DELTA##lambda#/sub L/ = 1 A, our maximum numerical value of the computed result for the three-photon excitation cross section is #sigma#/sub (3)/ = 1.414 x 10/sup -80/ cm"6 s"2. .AE.

8800-01-01

74

Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)  

Energy Technology Data Exchange (ETDEWEB)

The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV ({lambda} {congruent} 40{Angstrom}) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 {mu}. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component.

1993-05-01

75

Dosimetry of iodine-123 iomazenil in humans  

International Nuclear Information System (INIS)

The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).

76

Daytime Raman lidar measurements of water vapor during the ARM 1997 water vapor intensive observation period  

Energy Technology Data Exchange (ETDEWEB)

Because of the importance of water vapor, the ARM program initiated a series of three intensive operating periods (IOPs) at its CART (Cloud And Radiation Testbed) site. The goal of these IOPs is to improve and validate the state-of-the-art capabilities in measuring water vapor. To date, two of the planned three IOPs have occurred: the first was in September of 1996, with an emphasis on the lowest kilometer, while the second was conducted from September--October 1997 with a focus on both the upper troposphere and lowest kilometer. These IOPs provided an excellent opportunity to compare measurements from other systems with those made by the CART Raman lidar. This paper addresses primarily the daytime water vapor measurements made by the lidar system during the second of these IOPs.

1998-04-01

77

CFD analysis and overheating control of a turbine  

Energy Technology Data Exchange (ETDEWEB)

The thermal analysis of a turbine stack discharging exhaust gases to the atmosphere is presented. The examined turbine stack belongs to a gas lift plant for oil extraction located in the Gulf area. The analysis has been performed because an overheating of the anchor flange/bolts and of the concrete foundation occurred and caused small cracks in the upper layer of the foundation. A qualitative thermal analysis of the stack has pointed out that the main cause of the overheating was the thermal radiation in the air-filled region underneath the stack bottom plate. Detailed calculations performed by using a CFD code (Fluent ver. 6.0.12), cross-checked with measurements taken from site, have shown that a significant reduction of the heat flux to the foundation could be obtained by filling the above mentioned air region with an insulating material. The benefits of this solution are prevailing over those achievable with the installation of external ...

2004-11-01

78

DISTRIBUTION AND RANGE OF RADIONUCLIDE SORPTION COEFFICIENTS IN A SAVANNAH RIVER SITE SUBSURFACE: STOCHASTIC MODELING CONSIDERATIONS  

Energy Technology Data Exchange (ETDEWEB)

The uncertainty associated with the sorption coefficient, or K{sub d} value, is one of the key uncertainties in estimating risk associated with burying low-level nuclear waste in the subsurface. The objective of this study was to measure >648 K{sub d} values and provide a measure of the range and distribution (normal or log-normal) of radionuclide K{sub d} values appropriate for the E-Area disposal site, within the Savannah River Site, near Aiken South Carolina. The 95% confidence level for the mean K{sub d} was twice the mean in the Aquifer Zone (18-30.5 m depth), equal to the mean for the Upper Vadose Zone (3.3-10 m depth), and half the mean for the Lower Vadose Zone (3.10-18 m depth). The distribution of K{sub d} values was log normal in the Upper Vadose Zone and Aquifer Zone, and normal in the Lower Vadose Zone. To our knowledge, this is the first report of natural radionuclide Kd variability in the literature. ...

2010-01-11

79

Radiation thermocatalytic processes of hydrogen production from water  

International Nuclear Information System (INIS)

The results of studies of radiation-thermocatalytic water decomposition in the 673-773 K temperature range in the presence of BeO and titanium Y-type zeolite are presented. It is found that radiation-thermocatalytic processes of hydrogen production from water are characterized by a lower activation energy (55.4 kJ/mole) as compared with thermocatalytic processes (88.4 kJ/mole). The radiation-thermocatalytic process rate in the presence of oxide systems is not an additive sum of rates of radiation-catalytic (at 296-300 K) and thermocatalytic processes of water decomposition. On the basis of obtained results the conclusion is made that during radiation-catalytic decomposition of water in a heterogeneous system BeO + H_2O the main contribution into this process is made by excitons, radiation-chemical yields of excitons and non-equilibrium ...

80

Modulating factors in the expression of radiation-induced oncogenic transformation  

Energy Technology Data Exchange (ETDEWEB)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-08-01

81

Modulating factors in the expression of radiation-induced oncogenic transformation  

International Nuclear Information System (INIS)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-01-01

82

Testing and design of radon resisting membranes based on the experience from the Czech Republic  

International Nuclear Information System (INIS)

Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10"-"1"5 m"2/s to 10"-"8 m"2/s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by setting of the ...

83

Alloy 800: Low cycle fatigue curves as the basis for design against fatigue failure of HTR components  

Energy Technology Data Exchange (ETDEWEB)

For a reliable design against fatigue failure of high-temperature components of different types of the heat resistant material Alloy 800, verified parameters of the low-cycle fatigue (LCF) behaviour are required. These parameters were obtained by a scatterband evaluation of the results of low-cycle fatigue tests, using a computerized data bank which includes all available actual data sets. The results of the evaluation are presented as mean fatigue curves with the upper and lower boundary limits of the scatterbands. For the type Alloy 800 in the recrystallization annealed condition, the results cover a temperature range from 20 to 750deg C; for the solution annealed types they cover a temperature range from 20 to 950deg C. Specimens tested in HTR helium at high temperatures had longer lives than specimens tested in air. This effect was represented quantitatively by the ratio of the total strain ranges ...

1990-05-01

84

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide ...

2003-01-01

85

Spontaneous radiation from relativistic electrons in a taper undulator. Technical report  

Science.gov (United States)

The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser ...

1983-06-01

86

Radiation oxidation of phenol in petrochemical waste water. II  

International Nuclear Information System (INIS)

The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and inorganic additions. (B.S.).

1981-01-01

87

Effect of ionizing radiation on the properties of PLA packaging materials  

International Nuclear Information System (INIS)

Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)

88

Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band ...

1987-05-01

89

Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band ...

1985-01-01

90

A radiation monitoring system for nuclear fusion devices  

International Nuclear Information System (INIS)

Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)

2005-12-01

91

Seismic stratigraphy in the South Cretan fault valley system: A comparison with the upper Quaternary gravitative sedimentation of the region  

Energy Technology Data Exchange (ETDEWEB)

A synthesis of the sedimentation processes as deduced from the seismic stratigraphy and the deduced facies associations suggests the following. Small fans developed along the northern major fault line of the SCFVS and contains sediment fed directly from Crete through a series of small canyons, most of which trend perpendicular to the coast. However, the main east-west-trending valley transects the mid- and lower fan sectors and contains several intravalley basinal areas, converging toward the main Messara basin. Thus much of the suprafan sediment is reworked and longitudinally transported into the deeper basins. In these deeper intrabasinal and main basinal areas the thickness of the post-Messinian sediments generally exceeds 800 m and in places exceeds 1,500 m. Toward the south the SCFVS receives additional sediment from the Ptolemy Mountains and the Gavdos rise. Cores recovered along the SCFVS contain a remarkable association of sedimentary sequences which are interpreted as deposits ...

1988-08-01

92

Magnetobiostratigraphy of the continental Paleocene upper Coalspur and Paskapoo formations near Hinton, Alberta  

Energy Technology Data Exchange (ETDEWEB)

A chronology for Paleocene strata of the Hinton area of west-central Alberta was developed from the integration of a magnetostratigraphic and palynostratigraphic study of the upper Coalspur and middle to upper Paskapoo strata in the Coal Valley to Obed Mountain area. The study resulted in the compilation of a complete section of 1100 m of strata with a maximum sediment accumulation rate of 250 m/m.y. Four new informal biostratigraphic units were used to highlight stratigraphically useful bioevents not previously recognized in existing zonations. These strata range in age from magnetochron 29r to 24r and palynozones Wodehouseia spinata Zone, Aquilapollenites reticulatus Subzone through the Pistillipollenite mcgregorii Zone. The 3 intervals with the most rapid changes in the palynoflora were the earliest Paleocene; the transition from the early to middle Paleocene; and in the late Paleocene. Each coincides with critical times ...

2008-06-15

93

Lithology and evolution of the crust-mantle boundary region in the southwestern Basin and Range province  

Energy Technology Data Exchange (ETDEWEB)

Seismic transects in this area show a strongly reflective Moho of generally low relief, which, in the area of modern transects, consists of a thin zone (< 2 km thick) of short reflectors. The upper mantle is transparent and has a P{sub n} of 7.8-8.0 km/s similar to much of the western US. A lower crustal zone, 2-13 km thick, has variable internal reflectivity and a relatively low velocity of 6.6-6.8 km/s. Upper mantle peridotite xenoliths show both ductile and brittle deformational features and have structures and composition affected by magmatic intrusion; intrusions form complex dike systems and extensive zones of grain boundary infiltration in peridotite xenoliths. Whereas melt infiltration preceded and followed ductile deformation, brittle deformation, represented by closely spaced joint systems and faults, followed ductile deformation and is related to the youngest magmatic episodes. Lower crustal xenoliths are dominantly ...

1990-01-10

94

Fission-track age of a bentonitized ash bed and mammalian fauna from Nagrota formation (Upper Siwalik) of Jammu District, J and K, India  

International Nuclear Information System (INIS)

Fission-track age of a bentonitized volcanic ash bed occurring in the middle part of Nagrota Formation. Upper Siwalik, north of Uttarbaini, Jammu district, Jammu and Kashmir, has been determined to be 1.6 #+-# 0.2 m.y. B.P. The radiometric age obtained for the sample roughly coincides with the Olduvai Event (1.6-1.8 m.y.). However, the lithological and paleoclimatic changes in the Upper Siwalik success ion are indicated at the contact between Parmandal Sandstone and Nagrota Formation, i.e. about 1100 m below the 1.6 #+-# 0.2 m.y. datum line in this part. Vertebrat e fauna was studied from 16 sites beneath and 12 above the volcanic ash bed to interpret the biological and palaeoenvironmental aspects of the Nagrota Formation. The assemblage represented in the collection is similar to that of the Pinjor Biozone (Villafranchian) and is assigned a probable age ranging from about 2.9 m.y. to 1.0 m.y. B.P. The stratigraphic ...

95

Fish Research Project Oregon; Aspects of Life History and Production of Juvenile Oncorhynchus Mykiss in the Grande Ronde River Basin, Northeast Oregon, 1995-1999 Summary Report.  

Energy Technology Data Exchange (ETDEWEB)

Rotary screw traps, located at four sites in the Grande Ronde River basin, were used to characterize aspects of early life history exhibited by juvenile Onchorhychus mykiss during migration years 1995-99. The Lostine, Catherine Creek and upper Grande Ronde traps captured fish as they migrated out of spawning areas into valley rearing habitats. The Grande Ronde Valley trap captured fish as they left valley habitats downstream of Catherine Creek and upper Grande Ronde River rearing habitats. Dispersal downstream of spawning areas was most evident in fall and spring, but movement occurred during all seasons that the traps were fished. Seaward migration occurred primarily in spring when O. mykiss smolts left overwintering area located in both spawning area and valley habitats. Migration patterns exhibited by O. mykiss suggest that Grande Ronde Valley habitats are used for overwintering and should be considered critical rearing habitat. We were ...

2001-07-01

96

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

97

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)

98

Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study  

British Library Electronic Table of Contents (United Kingdom)

AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...

2011-01-01

99

Total cross sections for electron scattering by oxides of iron  

Energy Technology Data Exchange (ETDEWEB)

Total (elastic+inelastic) cross sections for electron impact on FeO, Fe{sub 2}O{sub 3} and Fe{sub 3}O{sub 4} have been calculated in the energy range 20-5000 eV by employing the additivity rule which expresses the total cross section of a molecule as an incoherent sum over the total cross sections of the constituent atoms of the molecule. The electron-atom cross sections have been obtained by a complex optical potential method through partial-wave analysis. The total cross sections for all the oxides of iron exhibit a maximum around 30 eV. The inelastic cross sections are upper bounds to the corresponding ionisation cross sections. Bethe parameters for inelastic cross sections are given. ((orig.))

1995-02-27

100

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

Energy Technology Data Exchange (ETDEWEB)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.

1984-03-01

101

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

International Nuclear Information System (INIS)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).

1983-07-01

102

Radioactivity in local and imported kaolin types used in Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials are present in all geological rocks in varying amounts, they are easily mobilized in the environment, and can reach hazardous radiological levels under certain conditions, requiring precautions to be taken. The present study deals with 50 geological samples of local (Tushki and Kalabsha in upper Egypt) and imported (southeast Asia and Turkey) kaolin types. The samples were analyzed by gamma-ray spectroscopy using a HPGe detector. The activity concentrations of {sup 232}Th and {sup 238}U series and {sup 40}K and the contents (in ppm) are given. The radium equivalent activity varied from 187.8 to 10185.19 Bq/kg. {sup 137}Cs was found in a range of 0.23-8.53 Bq/kg, for the local samples. The kaolin in Tushki area was suitable for industrial use.

2004-01-01

103

Optical-Model Description of Time-Reversal Violation  

CERN Document Server

A time-reversal-violating spin-correlation coefficient in the total cross section for polarized neutrons incident on a tensor rank-2 polarized target is calculated by assuming a time-reversal-noninvariant, parity-conserving ``five-fold" interaction in the neutron-nucleus optical potential. Results are presented for the system $n + {^{165}{\\rm Ho}}$ for neutron incident energies covering the range 1--20 MeV. From existing experimental bounds, a strength of $2 \\pm 10$ keV is deduced for the real and imaginary parts of the five-fold term, which implies an upper bound of order $10^{-4}$ on the relative $T$-odd strength when compared to the central real optical potential.

1994-01-01

104

On the disrupted magnetic braking model for the period gap of cataclysmic variables  

International Nuclear Information System (INIS)

The disrupted magnetic braking theory for the period gap of cataclysmic variable systems is used to study the binary evolution of low-mass main-sequence-like stars with white dwarf companions. The model is able to reproduce the observed location and width of the gap provided that the average mass transfer rates above the upper edge of the gap are greater than about 1.9 x 10 to the -9th solar masses/yr. For the case of angular momentum loss by magnetic braking, the slope of the mass transfer rate with respect to orbital period is shown to range from 3.4 to 3.7. For the evolutionary sequences considered, the He-3 abundance at the surface of the secondary exceeds 0.0015 after the complete mixing phase, resulting in modifications in the nuclear burning development of nova explosions. 31 refs.

105

Geology, physical properties, and surface effects at Discus Thrower Site, Yucca Flat, Nevada Test Site  

International Nuclear Information System (INIS)

Geologic studies in connection with Project Discus Thrower have furnished detailed stratigraphic and structural information about northwestern Yucca Flat, Nevada Test Site. The Paleozoic rocks consist of a lower carbonate sequence, argillite of the Eleana Formation, and an upper carbonate sequence. The distribution of these rocks suggests that both top and bottom of the Eleana are structural contacts, probably thrusts or reverse faults. The overlying tuff includes several units recognized in the subsurface, such as the Fraction Tuff and tuff of Redrock Valley. Other units recognized include bedded tuff associated with the Grouse Canyon Member of Belted Range Tuff, and the Rainier Mesa and Ammonia Tanks Members of the Timber Mountain Tuff. The Timber Mountain and Grouse Canyon are extensively altered to montmorillonite (a swelling clay), possibly as a result of ponding of alkaline water. The overlying alluvium locally contains at the base a ...

106

Gastric juice acidity in upper gastrointestinal diseases  

UK PubMed Central (United Kingdom)

AIM: To search the independent factors determining gastric juice acidity and to investigate the acidity of gastric juices in various benign and malignant upper gastrointestinal diseases.METHODS:...Full Text Available

2010-11-21

107

Chronic Pain Associated with Upper-Limb Loss  

UK PubMed Central (United Kingdom)

ObjectiveTo describe the prevalence, intensity, and functional impact of the following types of pain associated with upper-limb loss: phantom limb, residual limb,...Full Text Available

2009-09-01

108

Association of upper gastrointestinal symptoms with functional and clinical charateristics in elderly  

UK PubMed Central (United Kingdom)

AIM: To evaluate the prevalence of upper gastrointestinal symptoms and their association with clinical and functional characteristics in elderly outpatients.METHODS: The study involved 3238 outpatients...Full Text Available

2011-07-07

109

Upper Paleozoic petroleum system, Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The Ordos Basin is a typical lapped basin, including three sequences of strata: early Paleozoic, late Paleozoic and Mesozoic, with a total thickness of 4000-6000m. Impermeable sealing beds are well developed at the top and base of the upper Paleozoic sequence, separating it from the Mesozoic and the lower Paleozoic strata to form an independent petroleum system. In this petroleum system, the source rocks are widely distributed coals and dark mudstones occurring in the Carboniferous-lower Permian coal measures, with a thickness of 10-15 and 40-60m, respectively. The reservoirs are mainly early Permian tight sandstones, mostly with a porosity of 4-8% and a permeability of 0.1-1.0x10{sup -3}{mu}m{sup 2}. The regional cap rock is a 100-150m thick mudstone in the upper Permian strata. The structural framework of the basin is a huge asymmetric syncline, dipping gently toward the east and north, and steeply toward the south and west. Well data show ...

2005-09-01

110

The effect of irradiation on packaging materials  

International Nuclear Information System (INIS)

Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation doses used for the control of ...

111

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...

2007-07-01

112

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...

2007-05-10

113

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was ...

2010-12-01

114

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the ...

2004-07-19

115

Quaternary faults near the proposed Eagle Flat low-level radioactive waste repository, Trans-Pecos Texas  

Science.gov (United States)

The Eagle Flat basin, an intermontane basin in Trans-Pecos Texas, is being considered as a possible site for the Texas repository of low-level radioactive wastes. Intermontane basins and associated normal faults formed in response to Basin and Range tectonism that began about 24 Ma ago. The most active late Tertiary and Quaternary faults occur within the Hueco Bolson (HB) and the Salt Basin/Salt Flat/Lobo Valley, west and east, respectively, of the proposed repository. Several faults of the southeast HB which are within 50 km of the site, displace middle Pleistocene deposits 10 to 24 m. The most recent surface rupture in the southeast HB probably occurred on the Amargosa fault during the Holocene. Upper Pleistocene deposits are offset 2.5 to 4.5 m, and middle Pleistocene deposits are displaced 24 m. Fault scarps within 50 km east of the proposed repository are associated with faults bounding the Salt Basin/Salt Flat/Lobo Valley. In the southern ...

1992-01-01

116

Methionine kinetics and balance at the 1985 FAO/WHO/UNU intake requirement in adult men studied with L-[2H3-methyl-1-13C]methionine as a tracer  

International Nuclear Information System (INIS)

The upper range of the requirement for methionine plus cystine in healthy adults was proposed in 1985 by FAO/WHO/UNU to be 13 mg.kg body wt-1.d-1. To explore the validity of this estimate, five healthy, young adult men were given for 7 d a diet based on an L-amino acid mixture supplying 13 mg methionine.kg-1.d-1 (87 mumol.kg-1.d-1) without cystine. Constant intravenous infusions of L-[2H3-methyl-1-13C]methionine were given on days 5 and 7 while subjects were in the fed and postabsorptive states, respectively. Estimates were made of methionine oxidation, and daily methionine balance was derived from the intake-oxidation data. For the five subjects, methionine balances were -0.9, +0.7, +3.5, -3.1, and -3.8 mg kg-1.d-1, or -6, +5, +23, -21, and -26 mumol.kg-1.d-1. These findings lead to the conclusion that the upper range of the requirement for methionine plus cystine probably exceeds 13 mg.kg-1.d-1 in ...

117

SLAP Tears  

Science.gov (United States)

... your upper arm bone (humerus), your shoulder blade (scapula), and your collarbone (clavicle). The head of your ...

119

The circadian rhythm for the number and sensitivity of radiation-induced apoptosis in the crypts of mouse small intestine  

Energy Technology Data Exchange (ETDEWEB)

Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).

1990-07-01

120

Results of regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).

1986-01-01

121

Photon angular distribution of radiative electron capture into the M shell of He-like uranium ions at 110-140 MeV/u  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the photon angular distribution of Radiative Electron Capture into the M shell have been performed with He-like uranium ions in the range 110-140 MeV/u. In addition, L REC was studied at a projectile energy of 140 MeV/u. In both cases, the experimental data show an asymmetry around 90 and agree well with a fully relativistic theory. (orig.) 15 refs.

1995-10-01

122

Forward directed Smith-Purcell radiation from relativistic electrons  

International Nuclear Information System (INIS)

The requirements for the generation of forward directed Smith-Purcell emission from relativistic electrons are introduced, and the first experimental evidence of this phenomenon is presented. The experiments were conducted with a 2.8 MeV/c electron beam interacting with a 1 cm period grating. Radiation emitted in two bands with wavelengths ranging from 600 to 650 #mu#m and 1.2 to 1.7 mm were measured. Grating period to wavelength ratios were as high as 16. The measured intensities are higher than that predicted by incoherent emission.

123

Quantitative evaluation of bile diversion surgery utilizing /sup 99m/Tc HIDA scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

This is a report of 21 patients presenting with epigastric pain, bilious vomiting, upper gastrointestinal bleeding, iron-deficiency anemia, and weight loss, who had undergone Billroth II gastrectomy from 3 to 35 yr earlier. Eighteen of 21 patients were found to have significant enterogastric reflux indices varying from 60% to 95% demonstrated by /sup 99m/Tc HIDA scintigraphy. Thirteen patients had diversion antireflux surgery in the form of a Roux-en-Y procedure, and 1 patient had a Henley loop jejunal interposition. Postoperative /sup 99m/Tc HIDA scintigraphic studies showed the enterogastric reflux indices to have decreased significantly to a range of 2%-26% (p less than 0.00001). There was marked improvement of symptoms, including correction of anemia and weight gain in those patients who had been anemic or who had sustained earlier weight loss. The enterogastric reflux indices of 10 asymptomatic control patients after Billroth II ...

1983-02-01

124

Local and regional ozone production: Chemistry and transport  

International Nuclear Information System (INIS)

The EUROTRAC sub-project ''Tropospheric Ozone Research'' (TOR) follows a dual strategy: - Observation of the chemical processes contributing to the oxygen balance directly in the atmosphere; - Establishment of a validated data base for model calculations. Both tasks require simultaneous measurements of a wide range of chemical and meteorological components. In the case of the investigation of the chemical processes, it is also desirable to measure the free radicals directly involved in ozone production. In the project described, a measuring station was set up. For a period of two years and a half, continuous measurements were made of ozone and its chemical precursors (NO, NO_2, NO_y, VOC, CO), as well as other photooxidants (H_2O_2 and organic hydroperoxides, organic nitrates), the photolysis frequency of NO_2, and meteorological parameters (wind, temperature, moisture, aerosols). The station was located on the Schauinsland mountain in the southern Black Forest, at ...

125

Effect of gamma radiation on electrical and optical properties of (TeO_2)_0_._9 (In_2O_3)_0_._1 thin films  

International Nuclear Information System (INIS)

We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. ...

2011-02-01

126

Empirically Consistent Electroweak Radiative Corrections with the Two-Higgs Doublet Model  

CERN Document Server

The electroweak radiative correction, which turned out to be marginal within the standard electroweak model having the minimal Higgs sector in view of the present experimental information, fits well the experiment when the Higgs sector is extended to have two Higgs doublets. We predict the range where the charged and CP odd Higgs boson masses would lie, taking the two CP even neutral Higgs boson masses to be degenerate which makes the analysis in multiparameter space feasible. It is shown that the mass of neutral Higgs doublet boson can arbitrarily be large consistently with the $W$ mass, if the charged Higgs boson is present and it's mass lies in some appropriate ranges.

2008-01-01

127

Radiative Breaking of Gauge Symmetries in the MSSM and in its Extensions  

CERN Document Server

The radiative electroweak symmetry breaking, the b-\\tau Yukawa and gauge couplings unification in the MSSM and its SU(5) extensions are studied in detail. In the framework of the two-loop renormalization group equations both low- and high-energy threshold effects are included. In the case of the minimal SU(5), the values of \\alpha_s obtained are somewhat larger than the experimental average. The Peccei-Quinn version of the missing-doublet SU(5) model generally predicts smaller values of \\alpha_s and b-\\tau unification, in excellent agreement with all low energy experimental data. We also study the generation of the GUT scale through radiative corrections in the context of an R-symmetric ``flipped" SU(5) x U(1)_X model and we find that this is possible in a certain range of values of the parameter space.

1998-01-01

128

Detection of irradiated chicken by ESR spectroscopy of bone  

Energy Technology Data Exchange (ETDEWEB)

Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).

1995-10-01

129

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...

1984-10-01

130

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...

1984-10-01

131

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

132

Radiation processed sawdust-clay-plastic composite. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Wood sawdust has been applied to manufacture the sawdust-clay-plastic composite (SDCPC) by radiation process for the purpose of disposing large amount of wood sawdust waste material. The process comprises the impregnation of liquid vinyl monomers into the completely dried molded sawdust-clay specimens followed by exposure to Co-60 gamma-radiation to induce graft-copolymerization of the impregnated vinyl monomers onto the sawdust-clay matrix. The comonomer system of unsaturated polyester and vinyl compounds was found to be the ideal impregnating monomer for the preparation of the SDCPC from the viewpoint of the technological and economical advantages. The SDCPC material has a variety of the sawdust content which enables the composite to have wide range of mechanical properties, e.g., 410 to 1100 kg/cm/sup 2/ in compressive strength, 120 to 380 kg/cm/sup 2/ in tensile strength and 0.32 to 4.41 kg/mm/sup 2/ in static bending ...

1983-01-01

133

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It ...

2004-12-01

134

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised ...

1996-01-01

135

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of ...

1997-05-01

136

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

137

Upper bound for a three-photon excitation cross section in atomic argon in the ultraviolet regime  

Energy Technology Data Exchange (ETDEWEB)

A scheme of evaluating a generalized three-photon excitation cross section sigma/sub (3)/ in neutral atomic argon at 3144.67 A is outlined. Three photons at this wavelength can excite the neutral argon atoms from the ground 3p/sup 6/ /sup 1/S/sub 0/ state to the 3p/sup 5/4s'(1/2)/sub 1//sup 0/ state. The fourth photon will ionize the argon atoms. Assuming linear polarization of the incident laser radiation, contributions from several channels in various energy-level schemes are summed in the evaluation of the transition probability. For a laser linewidth of ..delta..lambda/sub L/ = 1 A, our maximum numerical value of the computed result for the three-photon excitation cross section is sigma/sub (3)/ = 1.414 x 10/sup -80/ cm/sup 6/ s/sup 2/. .AE

1989-04-15

138

The jet-powered optical nebula of Cygnus X-1  

CERN Document Server

We present H-alpha and [O III] (5007 Angstroms) images of the nebula powered by the jet of the black hole candidate and microquasar Cygnus X-1, observed with the 2.5m Isaac Newton Telescope (INT). The ring-like structure is luminous in [O III] and there exists a thin outer shell with a high [O III] / H-alpha flux ratio. This outer shell probably originates in the collisionally excited atoms close to the front of the bow shock. Its presence indicates that the gas is shock excited as opposed to photoionised, supporting the jet-powered scenario. The shock velocity was previously constrained at 20 = 100 km/s (1 sigma confidence) based on a comparison of the observed [O III] / H-alpha ratio in the bow shock with a number of radiative shock models. From this we further constrain the time-averaged power of the jet: P_Jet = (4 - 14)*10^36 erg/s. The H-alpha flux behind the shock front is typically 4*10^-15 erg/s/cm^2/arcsec^2, and we estimate an upper ...

2007-01-01

139

The behaviour of stratospheric and upper tropospheric ozone in high and mid latitudes; the role of ozone as a climate gas  

Energy Technology Data Exchange (ETDEWEB)

During the past few years, the dual role that ozone plays in climate change has been becoming increasingly obvious. First, continuous thinning of the ozone layer has been evident, even in the high and middle latitudes in the northern hemisphere. Secondly, ozone is also a greenhouse gas, affecting radiative transfer. Increases in tropospheric ozone have a positive forcing, whereas decreases in stratospheric ozone cause a negative forcing. During the last six years, measurements on total ozone and the vertical distribution of ozone have been performed at the Sodankylae Observatory. At Jokioinen Observatory, measurements on total ozone have been performed since 1990 and measurements on the vertical distribution of ozone since 1993. The overall project has focused on extending the national data series on total ozone and the vertical distribution of ozone. At the same time, the study has contributed to the study of interannual variability of the ozone layer. This SILMU ...

1996-12-31

140

Structural transformations in Sc/Si multilayers irradiated by EUVlasers  

Energy Technology Data Exchange (ETDEWEB)

Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers adjacent tothe ...

2007-08-21

141

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and analysis presented ...

2011-01-01

142

HD 75289Ab revisited - Searching for starlight reflected from a hot Jupiter  

CERN Document Server

Aims. We attempt to detect starlight reflected from a hot Jupiter, orbiting the main-sequence star HD 75289Ab. We report a revised analysis of observations of this planetary system presented previously by another research group. Methods. We analyse high-precision, high-resolution spectra, collected over four nights using UVES at the VLT/UT2, by way of data synthesis. We try to interpret our data using different atmospheric models for hot Jupiters. Results. We do not find any evidence for reflected light, and, therefore, establish revised upper limits to the planet-to-star flux ratio at the 99.9% significance level. At high orbital inclinations, where the best sensitivity is attained, we can limit the relative reflected radiation to be less than e = 6.7 x 10-5 assuming a grey albedo, and e = 8.3 x 10-5 assuming an Class IV function, respectively. This implies a geometric albedo smaller than p = 0.46 and p = 0.57, for the grey albedo and the ...

2008-01-01

143

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps that were taken to fulfill the imposed ...

2006-02-15

144

Correlations for the yearly or seasonally optimum salt-gradient solar pond in Greece  

Energy Technology Data Exchange (ETDEWEB)

Simple correlations and corresponding nomographs are presented, which express the maximum useful heat received from salt-gradient solar ponds throughout the year or during a specified season of the year, and the corresponding optimum depth of the nonconvective zone in terms of the thickness of the upper convective zone and the temperature under which the maximum useful heat is received. The correlations are valid for the Athens (Greece) area or for regions with a similar climate, because solar radiation and ambient temperature values for Athens have been employed, obtained by a statistical process of hourly measurements over a period of about 20 years. For other climates, it is easy to develop similar correlations using the same methodology, Development of the proposed correlations is based on a method, which simulates the transient operation of the salt-gradient pond using finite-differences, and calculates the useful heat received hourly ...

1993-05-01

145

Correction for loss of track density due to overlapping track on SSNTD  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This method also provides the privilege of ...

1990-06-01

146

Viscosity changes in hyaluronic acid: Irradiation and rheological studies  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly ...

2010-04-15

147

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

148

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

149

Mechanism of radiation induced carcinogenesis: does a threshold exist?  

International Nuclear Information System (INIS)

Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).

1996-10-23

150

Heat transfer  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.

1999-07-01

151

Electronic structure of the Ru(0001) surface  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the electronic structure of ruthenium. Synchrotron radiation in the range from 15 to 45 eV and angle-resolved ultraviolet photoemission are used to map the energies of the electronic states. The Fermi surface of Ru is determined using angle-resolved ultraviolet photoemission spectroscopy. The experimental results are compared with calculated photoemission spectra obtained within the framework of the one-step model of photoemission. (author)

2000-03-13

152

Electromagnetic effects in relativistic electron beam plasma interactions  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic effects excited by intense relativistic electron beams in plasmas are investigated using a two-dimensional particle code. The simulations with dense beams show large magnetic fields excited by the Weibel instability as well as sizeable electromagnetic radiation over a significant range of frequencies. The possible relevance of beam plasma instabilities to the laser acceleration of particles is briefly discussed. 6 refs., 4 figs.

1985-02-13

153

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...

1983-06-01

154

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a result of the low doses of radiation but also by preventing some of the endogenous ...

2006-04-01

155

Radiation-induced reduction of ditetrazolium salt in aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a ...

2002-04-01

156

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 ...

2006-02-01

157

Local Radiation MHD Instabilities in Magnetically Stratified Media  

CERN Document Server

We study local radiation magnetohydrodynamic instabilities in static, optically thick, vertically stratified media with constant flux mean opacity. We include the effects of vertical gradients in a horizontal background magnetic field. Assuming rapid radiative diffusion, we use the zero gas pressure limit as an entry point for investigating the coupling between the photon bubble instability and the Parker instability. Apart from factors that depend on wavenumber orientation, the Parker instability exists for wavelengths longer than a characteristic wavelength lambda_{tran}, while photon bubbles exist for wavelengths shorter than lambda_{tran}. The growth rate in the Parker regime is independent of the orientation of the horizontal component of the wavenumber when radiative diffusion is rapid, but the range of Parker-like wavenumbers is extended if there exists strong horizontal shear between field lines ...

2011-01-01

158

Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data  

Science.gov (United States)

The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an appropriate maximum of ...

2010-01-01

159

Chromosomal study in lymphocytes from subjects living or working in buildings constructed with radioactively contaminated rebar  

Energy Technology Data Exchange (ETDEWEB)

It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or ...

1997-07-03

160

Chromosomal study in lymphocytes from subjects living or working in buildings constructed with radioactively contaminated rebar  

International Nuclear Information System (INIS)

It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or ...

161

Augmentation of radiative heat transfer in an infinite cylindrical pipe enclosing a participating gas  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the ...

1992-10-01

162

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

Energy Technology Data Exchange (ETDEWEB)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...

1993-12-31

163

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

International Nuclear Information System (INIS)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...

164

TS-1 and TS-2 transient overpower tests on FFTF fuel  

International Nuclear Information System (INIS)

The TS-1 and TS-2 TREAT transient experiments subjected a low burnup (2 MWd/kg) and a medium burnup (58 MWd/kg), respectively, FFTF irradiated fuel pin to unprotected 5 cents/s overpower transient conditions. The fuel pin failure response was similar in the two tests, which demonstrated a large margin to failure (P/P_0 > 3) and a favorable upper level failure location. Thus, for these transient conditions, burnup effects on transient performance appeared to be minimal in the range tested. Pin disruption in the medium burnup TS-2 test was more severe due to the higher fission gas pressurization, but failure occurred at only a 5% lower power level than for the low burnup TS-1 fuel pin. Both tests exhibited axial extrusion of molten fuel to the region above the fuel column several seconds before pin failure, demonstrating a potentially beneficial inherent safety mechanism to delay failure and mitigate accident consequences.

1985-11-10

165

Surface tension of a coal extract in an organic solvent; Sekitan chushutsu seibun no kaigo to hyomen choryoku  

Energy Technology Data Exchange (ETDEWEB)

The behavior and properties of associated bodies were studied through measurement of surface tension considering acetone-soluble fraction relatively light among various solvent extracts of coal. In experiment, the acetone-soluble fraction was extracted from the substances extracted from Upper Freeport coal as standard specimen using the mixed solvent of carbon disulfide (CS2) and N-methyl-2-pyrrolidinone (NMP), and it was dissolved into NMP after drying. Surface tension was measured by Wilhelmy method. The experimental results are as follows. Equilibrium surface tension is equal to the surface tension of pure solvent in a low concentration range of solution, and decreases with an increase in concentration approaching a fixed value at 0 in log concentration, nearly showing an S curve. Adsorption of species with non-polar aromatic ring of the acetone-soluble fraction on a solution surface probably decreases surface tension. Change with time in ...

1996-10-28

166

Single-pulse excimer laser nanostructuring of silicon: A heat transfer problem and surface morphology  

Science.gov (United States)

We present computer modeling along with experimental data on the formation of sharp conical tips on silicon-based three-layer structures that consist of a single-crystal Si layer on a 1 {mu}m layer of silica on a bulk Si substrate. The upper Si layers with thicknesses in the range of 0.8-4.1 {mu}m were irradiated by single pulses from a KrF excimer laser focused onto a spot several micrometers in diameter. The computer simulation includes two-dimensional time-dependent heat transfer and phase transformations in Si films that result from the laser irradiation (the Stefan problem). After the laser pulse, the molten material self-cools and resolidifies, forming a sharp conical structure, the height of which can exceed 1 {mu}m depending on the irradiation conditions. We also performed computer simulations for experiments involving single-pulse irradiation of bulk silicon, reported by other groups. We discuss conditions under which different types ...

2008-05-01

167

SEAFP-2 bounding accident analyses  

Energy Technology Data Exchange (ETDEWEB)

Analyses have been performed of the potential consequences to the public of hypothetical loss-of-coolant accidents in conceptual fusion power plant designs. In order to establish upper bounds to the consequences of such events, a case has been studied in which total loss of all active cooling has been assumed, with no remedial intervention for the duration of the accident sequence. The analyses are based on three conceptual power plant designs, two of them similar to those assumed in the earlier safety and environmental assessment of fusion power (SEAFP) study (Raeder et al., 1995), with updating of assumed structural materials. The three models studied provide a broad range of design options. In all cases the decay-heat driven temperature transients are well below the level at which structural melting would begin. Based on conservative assumptions, mobilisation, release and dose calculations show that potential maximum doses to the public are ...

2000-09-01

168

Oil shale resonances of the Green River formation in the northeastern part of the Green River Basin, Wyoming  

Energy Technology Data Exchange (ETDEWEB)

Oil shale resource data are provided for a 1300-square mile area around Farson, Wyoming. The data were derived from analyses of samples from 14 core holes drilled by the US Bureau of Mines and the Department of Energy, plus 4 core holes drilled by private companies. Fischer assay oil yield data for nine stratigraphic resource units are tabulated, correlated, and contoured to provide an assessment of shale oil potential in the area. Oil shale resources in the northeastern part of the Green River Basin occur in the Laney Member and the upper part of the Wilkins Peak Member of the Eocene Green River Formation. A total in-place shale oil resource of 137 billion barrels was calculated for the area. Four stratigraphic resource units have average oil yields of 12 to 20+ gallons per ton within the area of investigation, and in some parts a section up to 275 feet thick averages as much as 15.9 gallons per ton. The thickness of overburden on the richest resource unit ...

1988-03-01

169

Non-Detection of Polarized, Scattered Light from the HD 189733b Hot Jupiter  

CERN Document Server

Using the POLISH instrument, I am unable to reproduce the large-amplitude polarimetric observations of Berdyugina et al. (2008) to the >99.99% confidence level. I observe no significant polarimetric variability in the HD 189733 system, and the upper limit to variability from the exoplanet is Delta_P < 7.9 x 10^(-5) with 99% confidence in the 400 nm to 675 nm wavelength range. Berdyugina et al. (2008) report polarized, scattered light from the atmosphere of the HD 189733b hot Jupiter with an amplitude of two parts in 10^4. Such a large amplitude is over an order of magnitude larger than expected given a geometric albedo similar to other hot Jupiters. However, my non-detection of polarimetric variability phase-locked to the orbital period of the exoplanet, and the lack of any significant variability, shows that the polarimetric modulation reported by Berdyugina et al. (2008) cannot be due to the exoplanet.

2009-01-01

170

New fuzzy dynamic programming approach for solving the hydrothermal scheduling problem  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new approach for solving multistage decision problems in power system operation by using a new fuzzy dynamic programming technique. To investigate its validity, the hydrothermal scheduling problem is used as an example problem. Within this problem, uncertainty elements exist such as load demand and natural hydraulic inflows to reservoirs exist which can be expressed by fuzzy numbers. Two new fuzzy decision making techniques for selecting the optimal operating states at each stage are introduced. Further, the hydrothermal scheduling solution obtained had an operating band defined by upper and lower bounds. To further enhance the information that this operating band provides, a midpoint operation technique that applies both forward and backward fuzzy DP is also introduced. This allows the system operator to consider current operating conditions to determine a suitable stage by stage operation policy within the bounds of the initial solution. By ...

1997-03-20

171

New constraints on the primordial black hole number density from Galactic gamma-ray astronomy  

CERN Document Server

Primordial black holes are unique probes of cosmology, general relativity, quantum gravity and non standard particle physics. They can be considered as the ultimate particle accelerator in their last (explosive) moments since they are supposed to reach, very briefly, the Planck temperature. Upper limits on the primordial black hole number density of mass $M_{\\star} = 5 10^{14}$ g, the Hawking mass (born in the big-bang terminating their life presently), is determined comparing their predicted cumulative $\\gamma$-ray emission, galaxy-wise, to the one observed by the EGRET satellite, once corrected for non thermal $\\gamma$-ray background emission induced by cosmic ray protons and electrons interacting with light and matter in the Milky Way. A model with free gas emissivities is used to map the Galaxy in the 100 MeV photon range, where the peak of the primordial black hole emission is expected. The best gas emissivities and additional model ...

2009-01-01

172

Microrheological Studies of Regenerated Silk Fibroin Solution by Video Microscopy  

CERN Document Server

We have carried out studies on the rheological properties of regenerated silk fibroin (RSF) solution using video microscopy. The degummed silk from the Bombyx mori silkworm was used to prepare RSF solution by dissolving it in calcium nitrate tetrahydrate-methanol solvent. Measurements were carried out by tracking the position of an embedded micron-sized polystyrene bead within the RSF solution through video imaging. The time dependent mean squared displacement (MSD) of the bead in solution and hence, the complex shear modulus of this solution was calculated from the bead's position information. An optical tweezer was used to transport and locate the bead at any desired site within the micro-volume of the sample, to facilitate the subsequent free-bead video analysis. We present here the results of rheological measurements of the silk polymer network in solution over a frequency range, whose upper limit is the frame capture rate of our camera, at ...

2007-01-01

173

Influence of long-time stress relief treatments on the dynamic fracture toughness properties of ASME SA508 C1 2a and ASME SA533 GR B C12 pressure vessel steels  

Energy Technology Data Exchange (ETDEWEB)

Dynamic fracture toughness tests were performed on materials which had been subjected to one of three long-time post weld type stress relief heat treatments: 48 hours at 1000/degree/F (538/degree/C), 24 hours at 1125/degree/F (607/degree/C), and 48 hours at 1125/degree/F (607/degree/C). Linear elastic K/sub Id/ results were obtained at low temperatures while J-integral techniques were utilized to evaluate dynamic fracture toughness over the transition and upper shelf temperature ranges. Tensile, Charpy impact, and drop weight nil-ductility transition tests as well as room temperature, air environment fatigue crack growth rate tests (SA508 Cl 2a only) were also performed. The fracture toughness of both materials exceeded the ASME specified minimum reference toughness K/sub IR/ curve. 17 refs.

1982-03-01

174

Influence of long-time stress relief treatments on the dynamic fracture toughness properties of ASME SA508 C1 2a and ASME SA533 GR B C12 pressure vessel steels  

International Nuclear Information System (INIS)

Dynamic fracture toughness tests were performed on materials which had been subjected to one of three long-time post weld type stress relief heat treatments: 48 hours at 1000/degree/F (538/degree/C), 24 hours at 1125/degree/F (607/degree/C), and 48 hours at 1125/degree/F (607/degree/C). Linear elastic K/sub Id/ results were obtained at low temperatures while J-integral techniques were utilized to evaluate dynamic fracture toughness over the transition and upper shelf temperature ranges. Tensile, Charpy impact, and drop weight nil-ductility transition tests as well as room temperature, air environment fatigue crack growth rate tests (SA508 Cl 2a only) were also performed. The fracture toughness of both materials exceeded the ASME specified minimum reference toughness K/sub IR/ curve. 17 refs.

175

Fast Flooding over Manhattan  

CERN Document Server

We consider a Mobile Ad-hoc NETwork (MANET) formed by n agents that move at speed V according to the Manhattan Random-Way Point model over a square region of side length L. The resulting stationary (agent) spatial probability distribution is far to be uniform: the average density over the "central zone" is asymptotically higher than that over the "suburb". Agents exchange data iff they are at distance at most R within each other. We study the flooding time of this MANET: the number of time steps required to broadcast a message from one source agent to all agents of the network in the stationary phase. We prove the first asymptotical upper bound on the flooding time. This bound holds with high probability, it is a decreasing function of R and V, and it is tight for a wide and relevant range of the network parameters (i.e. L, R and V). A consequence of our result is that flooding over the sparse and highly-disconnected suburb can be as fast as ...

2010-01-01

176

Polymeric radioactive waste disposal containers: an investigation into the application of polymers vice metals to house low and intermediate level radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The research carried out in Canada in the design of containers for the disposal of radioactive waste has focussed on spent nuclear fuel, even though the quantities of other currently stored radioactive wastes are substantially greater. Research carried out at the Royal Military College of Canada on the effects of mixed fields of radiation on high polymer adhesives and composite materials has shown that some polymers are quite resistant to radiation and could well serve in the fabrication of radioactive waste disposal containers. The purpose of this research was to determine if thermoplastic polymers could be used as superior materials to replace metals in the application of low and intermediate level radioactive waste disposal containers. Polymers have the advantage that they do not corrode like metals. The experimental methods, used in this research, focused on the effects of radiation on the properties of the materials. ...

2001-07-01

177

Synergism between Prior Anisakis simplex Infections and Intake of NSAIDs, on the Risk of Upper Digestive Bleeding: A Case-Control Study  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to investigate the relationship between prior Anisakis infections and upper gastrointestinal bleeding (UGIB), and its interaction...Full Text Available

178

Prosthesis use in persons with lower- and upper-limb amputation  

UK PubMed Central (United Kingdom)

This study identified clinical (e.g., etiology) and demographic factors related to prosthesis use in persons with upper- and lower-limb amputation (ULA and LLA, respectively) and the effect...Full Text Available

2008-01-01

179

Prolonged Airway Obstruction after Posterior Occipitocervical Fusion: A Case Report and Literature Review  

UK PubMed Central (United Kingdom)

The purpose of this paper was to inform the reader that prolonged upper airway obstruction after posterior cervical spine surgery is a possible complication for patients with metastatic tumor of upper...Full Text Available

2011-01-01

180

Comprehensive Management of Upper Tract Urothelial Carcinoma  

UK PubMed Central (United Kingdom)

Urothelial carcinoma of the upper urinary tract represents only 5% of all urothelial cancers. The 5-year cancer-specific survival in the United States is roughly 75% with grade and stage being the most...Full Text Available

2009-01-01

181

Association of Nasophyaryngeal Bacterial Colonization during Upper Respiratory Tract Infection and the Development of Acute Otitis Media  

UK PubMed Central (United Kingdom)

Acute Otitis Media occurs mostly after upper respiratory tract infection; the causative bacteria are those colonized in the nasopharynx. We studied 709 URI episodes and found that children with...Full Text Available

2008-02-15

182

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

183

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

184
185

Blood cadmium concentrations in the general population of Umbria, Central Italy  

Energy Technology Data Exchange (ETDEWEB)

The aims of this study were (a) to assess blood cadmium (B-Cd) concentrations and to establish a tentative reference interval; (b) to identify significant determinants of B-Cd, in a population from Umbria, Central Italy, which was not occupationally exposed to cadmium (Cd). Four hundred and thirty-four healthy blood-donors volunteered to answer a questionnaire and provide a blood sample for B-Cd analysis, which was performed by graphite furnace atomic absorption spectrophotometry. Blood Cd concentrations ranged from non-detectable values, i.e. below 0.1 {mu}g/l up to 3.4 {mu}g/l and were not normally distributed. The median values and the 95th percentiles were 0.7 and 2.0 {mu}g/l, respectively. Concentrations of B-Cd were more than double in smokers than in non-smokers, median values being 1.1 {mu}g/l and 0.5 {mu}g/l, respectively. In current smokers, B-Cd values correlated with the number of cigarettes smoked daily (r{sub s}=0.40, P=0.0001) and with the cumulative ...

1999-02-02

187

System integration of pattern recognition, adaptive aided, upper limb prostheses  

Science.gov (United States)

The requirements for successful integration of a computer aided control system for multi degree of

1975-01-01

188

Coblation Assisted Tonsillectomy  

Medline Plus

... which extend beyond the upper airway. These include attention deficit hyperactivity disorder, learning disorders, failure to thrive, and enuresis. Tonsillectomies ...

189

About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

The presentation gives a brief insight on possibility of using the VEERA facility in studying the stratification phenomenon. The idea for such experiments is to use the facility upper plenum part to simulate the conditions in upper part of horizontal steam generator hot collector. The upper part of steam generator hot collector is one of the locations where the stratification can take part during natural circulation mode. 4 refs.

1997-12-31

190

Thermal and tectonic history of the Ordos Basin, China: Evidence from apatite fission track analysis, vitrinite reflectance, and K-Ar dating  

Energy Technology Data Exchange (ETDEWEB)

Apatite fission track analysis, vitrinite reflectance data, and K-Ar dating of Permian-Carboniferous and Mesozoic core samples have been successfully integrated to reconstruct the thermal and tectonic history of the Ordos basin, China. Apatite fission track ages of Carboniferous-Jurassic sedimentary rocks range between 3 and 137 Ma, and are significantly younger than the stratigraphic ages. Confined fission track lengths demonstrate exclusively mixed length distribution, indicating complex thermal history. The data suggest that the samples must have all experienced higher paleotemperatures in the past. Mean virtinite reflectance values (R{sub o}) of the Triassic rocks range from 0.61 to 1.06%, giving a high coalification gradient of 0.36%/km and suggesting a high paleothermal gradient of 57{degrees}C/km. Permian-Carboniferous rocks have R{sub o} values on the order of 1.0-3.0%, and locally up to 4.0-6.0%. Some high R{sub o} values coincide with ...

1996-07-01

191

Style and magnitude of Mesozoic thrust faulting in the hinterland of the Sevier thrust belt Pequop Mountains-Wood Hills-East Humboldt Range region, northeast Nevada  

Energy Technology Data Exchange (ETDEWEB)

The Pequop Mountains (PM), Wood Hills (WH) and East Humboldt Range (EHR), NE Nevada, provide evidence that the hinterland of the Sevier thrust belt experienced large-magnitude Mesozoic shortening ([>=]55 km) and crustal thickening ([>=] 30 km). These ranges expose a structurally continuous crustal cross section of unmetamorphosed to high pressure upper amphibolite facies Triassic to Precambrian miogeoclinal strata. This sequence lies structurally beneath unmetamorphosed extensional klippen that omit metamorphic grade and crustal section, but also repeat stratigraphic units. Because they repeat stratigraphic units, the underlying miogeoclinal section, or footwall, must have once lain beneath a thrust fault (herein named the Windermere thrust). The footwall of the Windermere thrust was exhumed by two generations of top-to-the-W-NW low-angle normal faults that are distinguished by whether they are depositionally ...

1993-04-01

192

Analysis of the direct contamination pathway of "8"5Sr, "1"0"3Ru and "1"3"4Cs in radish  

International Nuclear Information System (INIS)

For analyzing the direct contamination pathway of the radionuclide in radish, a solution containing "8"5Sr, "1"0"3Ru and "1"3"4Cs was sprayed to the aerial part of the plant in a greenhouse at 5 different times before harvest. Plant interception factor showed little difference among radionuclides and increased with decreasing time interval between application and harvest with the maximum value of 0.86. The fractions of the initial deposition that remained in the radish plant at harvest were in the range of 16#approx#37% for "8"5Sr, 15#approx#68% for "1"0"3Ru and 35#approx#58% for "1"3"4Cs. The remaining fraction was the highest in "1"3"4Cs at earlier applications while it was the highest in "1"0"3Ru at later applications. Translocation factors of "8"5Sr, "1"0"3Ru and "1"3"4Cs were in the range of 3.2x10"-"3#approx#1.7x10"-"2 , 7.3x10"-"4#approx#2.6x10"-"2 and 6.6x10"-"2#approx#1.7x10"-"2, respectively, in upper root and in ...

2000-05-01

193

Effect of elevated temperatures on the performance of an InP cell illuminated by a selective emitter  

Energy Technology Data Exchange (ETDEWEB)

The thermophotovoltaic (TPV) option was not selected for further deep space mission technology development in NASA for several reasons. Chief among them was the large radiator required to keep the photovoltaic cells at a sufficiently low operating temperature. This led to significant integration problems with the spacecraft and limited sensor view angles. It is clear that the issue of cell temperature is crucial for space applications because of radiator size and system impact. Many efforts have focused on matching cell band gap to appropriate emitters in the 1 to 2 {mu}m range, resulting in band gaps in the 0.5 to 0.8 eV range. However, low band gaps lead to low open circuit voltages ({approximately}0.25 to 0.45 V) caused by high intrinsic carrier concentrations (n{sub i}{sup 2}). Thus, in order to obtain high performance. Photovoltaic cell temperatures must be kept near room temperature. This leads to ...

1999-03-01

194

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical ...

2008-07-01

195

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was ...

1982-01-01

196

Regulation of naturally occurring radioactive materials in Australia  

British Library Electronic Table of Contents (United Kingdom)

In order to promote uniformity between jurisdictions, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has developed the National Directory for Radiation Protection, which is a regulatory framework that all Australian governments have agreed to adopt. There is a large and diverse range of industries involved in mining or mineral processing, and the production of fossil fuels in Australia. Enhanced levels of naturally occurring radionuclides can be associated with mineral extraction and processing, other industries (e.g. metal recycling) and some products (e.g. plasterboard). ARPANSA, in conjunction with industry and State regulators, has undertaken a review and assessment of naturally occurring radioactive material (NORM) management in Australian industries. This rev...

2011-01-01

197

Proposal for a free electron laser driven by the 7 MeV NILPRP linac  

International Nuclear Information System (INIS)

The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeV electron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)

198

Phenomenological models  

Energy Technology Data Exchange (ETDEWEB)

The biological effects of ionizing radiation exposure are the result of a complex sequence of physical, chemical, biochemical, and physiological interactions. One way to begin a search for an understanding of health effects of radiation is through the development of phenomenological models of the response. Many models have been presented and tested in the slowly evolving process of characterizing cellular response. A range of models covering different endpoints and phenomena has developed in parallel. Many of these models employ similar assumptions about some underlying processes while differing about the nature of others. An attempt is made to organize many of the models into groups with similar features and to compare the consequences of those features with the actual experimental observations. It is assumed that by showing that some assumptions are inconsistent with experimental observations, the job of devising and ...

1990-09-01

199

Nuclear Battery As An Alternative Source Of Direct Current Electricity  

International Nuclear Information System (INIS)

Nuclear battery produces electricity by converting radiation energy into electrical energy. Energy carried by particles emitted by a radioisotope nuclei is much higher than that released in chemical reaction. Reaction with nuclei can potentially produce electricity thousand to million times higher than that of chemical reaction. Unlike NPP that produces large scale alternating current using thermodynamic cycle such as Rankine or Brayton cycles, nuclear battery is designed like other battery or fuel cell, to produce direct current (DC). However, both battery utilize the energy or particles radiating from nuclei of a radioisotope. In this paper, several types of nuclear battery as an energy converter are discussed, including their working mechanisms and examples. Nuclear battery is potential to become a long-life power source for use in wide range of applications, including in medical areas and for instruments in remote areas ...

2000-11-01

200

Free electron laser inertial thermonuclear synthesis  

International Nuclear Information System (INIS)

The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.

201

Fast neutron irradiation induced changes in the optical and thermal properties of modified polyvinyl chloride  

International Nuclear Information System (INIS)

The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10"9 n/cm"2. The optical energy gap E_o_p exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C_p showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author).

1994-11-01

202

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

203

Effect of some chemicals on the radiation-induced lipid peroxidation  

International Nuclear Information System (INIS)

The effect of exposure to gamma rays on LPO contents in liver, spleen and kidney of mice and the anti-lipid-peroxidation of preparations of chinonin, tannic acid and squalene were reported. All these preparations were given by intragastric perfusion. For LPO, a modified method of TBA spectrophotometry was used for determination. The results show that LPO contents in tissues increased 72 h after whole-body exposure of mice to gamma rays, that in range of 0-4 Gy, there was a linear relationship between radiation doses and LPO contents, and that all three preparations were effective in reduction of the LPO content in liver, spleen and kidney of mice, with chinonin (at dose of 0.35 mg/mouse#centre dot#day) being more effective than tannic acid (at dose of 15 mg/mouse#centre dot#day) and squalene (at dose of 0.6 mg/mouse#centre dot#day).

204

Deep-level defects and numerical simulation of radiation damage in GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).

1991-09-01

205

Atomic processes in high temperature plasmas  

International Nuclear Information System (INIS)

Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.

1990-01-01

206

A radiation hardening model of 9%Cr-martensitic steels including dpa and helium  

British Library Electronic Table of Contents (United Kingdom)

This paper provides a physically-based engineering model to estimate radiation hardening of 9%Cr-steels under both displacement damage (dpa) and helium. The model is essentially based on the dispersed barrier hardening theory and the dynamic re-solution of helium under displacement cascades but incorporating a number of assumptions and simplifications [Trinkaus, J. Nucl. Mater. 318 (2003) 234-340]. As a result, the kinetics of the damage accumulation kept fixed, its amplitude is fitted on one experimental condition. The model was rationalized on an experimental database that mainly consists of 9%Cr-steels irradiated in the range of 50-600degreeC up to 50dpa and with a He-content up to 5000appm. The test temperature effect is taken into account through a normalization procedure based on the...

2009-01-01

207

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01

208

The efficacy of low-dose radiation therapy and surgical resection for Ewing's sarcoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis received whole-lung irradiation to 1400 cGy in 10 fractions. ...

1996-09-01

209

New short-range electromagnetic current in the deuteron  

International Nuclear Information System (INIS)

A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a clear physical meaning), is able to describe, in very good agreement with the ...

2007-02-01

210

Upper limb dysfunction following selective neck dissection: A retrospective questionnaire study  

British Library Electronic Table of Contents (United Kingdom)

Background. To determine total upper limb function following selective neck dissection over a mean follow-up of 1.6 years. Methods. A retrospective questionnaire study in a tertiary head and neck surgical unit. One hundred forty-eight patients who underwent selective neck dissection for head and neck cancer from January 2000 to December 2005 were invited to participate. The main outcome measure was ipsilateral upper limb dysfunction as measured by the Disability of Arm, Shoulder and Hand (DASH) questionnaire. Results. Sixty-five patients responded to the invitation to join the study from 148 invited. Despite accessory nerve conserving surgery for all the selective neck dissections studied, 23% reported no upper limb dysfunction, 54% reported mild upper limb dysfunction, 15% reported modera...

2009-01-01

211

The enhanced genomic instability was induced by alpha particle and low-energy ion irradiation in somatic cells of Arabidopsis thaliana  

International Nuclear Information System (INIS)

Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. The local alpha ...

2008-08-12

212

Radiation hardening and radiation-induced chromium depletion effects on intergranular stress corrosion cracking in austenitic stainless steels  

International Nuclear Information System (INIS)

Radiation hardening and radiation-induced chromium (Cr) depletion were related to intergranular stress corrosion cracking (IGSCC) response among various stainless steels (SS). Available data on neutron-irradiated materials were analyzed and correlations developed between fluence, yield strength, grain-boundary Cr concentration, and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 neutrons/cm"2 to 2.5 x 10"2"1 neutrons/cm"2) for IGSCC were documented. Variability often was consistent with yield strength differences among irradiated materials. IGSCC correlated better to yield strength than to fluence for most heats, suggesting a possible role for radiation-induced hardening (and microstructure) on cracking. However, isolated heats revealed a wide range of yield strengths (450 MPa to 800 MPa) necessary to promote IGSCC which could ...

213

Development of a pump-probe facility combining a far-infrared source with laser-like characteristics and a VUV free electron laser  

International Nuclear Information System (INIS)

The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR ...

2001-12-21

214

The radon therapy - radon inhalatorium in Kowary  

International Nuclear Information System (INIS)

In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)

215

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

216

Simple calculation of daily photosynthesis by means of five photosynthesis-light equations  

Energy Technology Data Exchange (ETDEWEB)

The performance of five well-known photosynthesis-light equations is compared by presenting a wide range of solutions in the form of dimensionless nomographs for the case where photosynthetically available radiation (PAR) reduces exponentially down the water column and is distributed sinusoidally through the photoperiod. These provide a simple means of calculating daily photosynthesis at any depth (e.g. at a benthic layer), or through a water column, avoiding the need to perform complex integrations. An examination is made of the accuracy of common approximate methods for calculating daily photosynthesis, assuming constant PAR. For optically deep water a modification is proposed to Talling's planimetric solution, to enable daily photosynthesis to be calculated more accurately, yet simply, over the whole range of possible PAR values. The errors induced by approximating the daily PAR distribution as a half-sinusoid ...

1992-12-01

217

Ewing's sarcoma of the vertebral column  

International Nuclear Information System (INIS)

Twenty-two patients with vertebral primaries were registered in the Intergroup Ewing's Sarcoma Study between 1973 and 1977. The radiation doses to the primary tumors ranged between 3800 and 6200 rad. All patients received intensive combination chemotherapy. After a followup ranging between 14 and 62 months, 14 patients remained disease-free. All patients with primary tumor of the cervical and dorsal spine remained disease-free. Of eight patients with lesions in the distal spine, (sacrococcygeal region) six developed recurrence, in three a local recurrence was observed despite doses of 6000 rad or higher. Doses of 5000 rad or less (in addition to combination chemotherapy as used in the Intergroup Ewing's Study) appear adequate in controlling the primary tumors of the proximal segments of the spinal column.

218

Efficient, low emissions gas range cooktop  

Energy Technology Data Exchange (ETDEWEB)

Disclosed is a gas-fired cooktop for a range which provides high thermal efficiency and low emissions of air pollutants, particularly low levels of NO{sub x}. The cooktop includes a perforated tile burner which radiates infrared energy upward at a high flux rate to rapidly quench burner gas temperatures and inhibit the formation of NO{sub x}. A perforated glass-ceramic jet plate positioned between the burner and a cooking vessel transmits most of the radiant infrared energy from the burner to the vessel and also forms jets of combustion products which are directed against the bottom of the vessel fo convective heating. Thermal efficiencies of up to about 70% and NO{sub x} emissions as low as about 15ppM are achieved by the cooktop.

1990-01-09

219

Thermal expansion of gamma irradiated nylon 66 from 10 K to 340 K  

Energy Technology Data Exchange (ETDEWEB)

Samples of nylon 66 rods were irradiated using a cobalt-60 gamma ray source at a dose rate of 0.25 Mrad h[sup -1] in air at room temperature to a maximum dose of 500 Mrad. The linear coefficient of thermal expansion ([alpha]) was measured using a three-terminal capacitance technique reported previously. The variation of [alpha] with temperature between 10 K and 340 K was investigated for an unirradiated sample and two samples irradiated to 300 Mrad and 500 Mrad. In the range 10K to 160K, [alpha] is almost invariant with radiation dose and there is little difference between the values for the unirradiated and the 300 Mrad irradiated samples above 160 K. The sample irradiated to 500 Mrad does show a 6% increase in [alpha] over the other samples in the higher temperature range. All samples show an increase overall in the value of [alpha] with temperature. The melting point of each sample was also determined and was shown to ...

1994-08-15

220

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have ...

1995-08-21

221

Radiation processing as a post-harvest quarantine control for raisins, dried figs and dried apricots  

International Nuclear Information System (INIS)

The commercially packed samples of raisins, dried figs and dried apricots were irradiated using doses in the range of 0.5-1.0 kGy for disinfestation and 0.5-5.0 kGy for sensory analysis with the dose rate ranging from 1.44 to 1.92 kGy/h. Pests on dried fruits were evaluated after 0, 1, 2 and 3 months of storage for irradiated dried figs and 1, 3, 6 and 12 months of storage for raisins and dried apricots. Sensory analysis of dried figs, dried apricots and raisins were carried out after 0, 1, 3, 6 and 12 months of storage. The results indicated that radiation processing at low doses (#approx#1.0 kGy) is an effective post-harvest treatment and quarantine control for these products with no adverse effects on sensory (marketing) attributes.

2006-03-01

222

Broad-band stigmatic spectrograph for the soft x-ray range  

International Nuclear Information System (INIS)

We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)

1998-09-30

223

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area ...

2002-01-01

224

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution ...

1991-06-01

225

Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus  

International Nuclear Information System (INIS)

Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.

1987-08-01

226

Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis  

International Nuclear Information System (INIS)

The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including ...

2003-06-01

227

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires ...

1997-07-01

228

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major ...

1986-01-01

229

Biological effects of low level exposures to chemicals and radiation  

International Nuclear Information System (INIS)

In May 1990 a group of scientists representing several federal agencies, the International Society of Regulatory Toxicology and Pharmacology, the private sector, and academia met to develop a strategy to encourage the study of the biological effects of low level exposures (BELLE) to chemical agents and radioactivity. A workshop was held in 1991 with seven invited speakers focusing on the toxicological implications of biological adaptations. The selection of topics and speakers was designed to consider critically the concept of hormesis, not only in a broad, conceptual manner, but also at the molecular and biochemical levels. These presentations offered a complementary perspective on the diverse range of molecular mechanisms that can become activated at low levels of toxicant exposure. In addition to chemical toxicology research, an overview of current research on 'Effects of low-dose radiation on the immune response' was presented as well as ...

230

Additive effects common to radiation grafting and wood plastic composite formation  

Energy Technology Data Exchange (ETDEWEB)

A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium ...

1996-08-01

231

Towards optimal use of available technical resources for regulatory purposes. The Syrian experience  

International Nuclear Information System (INIS)

The Atomic Energy commission of Syria (AECS) is nominated by Syrian legislation as the regulatory authority in respect of radiation protection and safety and security of radioactive sources. In addition AECS is providing a wide range of Technical Services (TS) through its various departments. In this paper, the cooperation and coordination between the regulatory authority and the providers of technical services in Syria are described. The adjustment of the regulatory programme as to make maximal use of the available technical resources is presented. It was shown that this relationship does not jeopardize the effective independency of the regulatory authority which is maintained by keeping the regulatory decisions based on pure regulatory considerations. (author)

2007-08-01

232

Properties of composite materials on the base of radiation-hardening binders and metal powders  

International Nuclear Information System (INIS)

Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.

233

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy X-rays  

International Nuclear Information System (INIS)

A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)

2010-12-01

234

Interplay between the ray and mode effects in electromagnetic behavior of small-size hemielliptic dielectric lenses  

CERN Document Server

Focusing and resonance properties of two-dimensional small-size hemielliptic lenses made of different materials are studied numerically in order to estimate the influence of internal reflections on the radiation characteristics of dielectric lens antennas. Accuracy of in-house made algorithms based on combination of geometrical and physical optics and FDTD in the analysis of optical and modal effects in the behavior of such lenses is tested by comparison with the exact solution obtained using the Muller boundary integral equations. The range of applicability for the approaches is discussed.

2010-01-01

235

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

236

Induction of sterility in adults of Earias vittella Fabricius through late pupal irradiation  

International Nuclear Information System (INIS)

Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).

237

EXAFS Study of Semimetal-Semiconductor Transition of Bismuth Clusters  

International Nuclear Information System (INIS)

Extended X-ray absorption fine structure (EXAFS) measurements of bismuth clusters in the temperature range of 23 -300 K have been performed using synchrotron radiation in order to investigate the size dependent phase transition. The inter-atomic distances around 3.0 A and 3.6 A are attributed to the nearest neighbors within the layer and between layers, respectively. EXAFS functions were analysed by the curve fitting method within a symmetric distribution approximation. The nearest neighbor distance of the 0.5 nm thick films is shorter than that of the 300 nm thick films at all the temperatures, which is related to the reduction of the inter-layer correlation.

2007-02-02

238

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

239

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

240

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

241

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well ...

2005-09-01

242

Pitting corrosion of copper. Further model studies  

Energy Technology Data Exchange (ETDEWEB)

The work presented in this report is a continuation and expansion of a previous study. The aim of the work is to provide background information about pitting corrosion of copper for a safety analysis of copper canisters for final deposition of radioactive waste. A mathematical model for the propagation of corrosion pits is used to estimate the conditions required for stationary propagation of a localised anodic corrosion process. The model uses equilibrium data for copper and its corrosion products and parameters for the aqueous mass transport of dissolved species. In the present work we have, in the model, used a more extensive set of aqueous and solid compounds and equilibrium data from a different source. The potential dependence of pitting in waters with different compositions is studied in greater detail. More waters have been studied and single parameter variations in the composition of the water have been studied over wider ranges of concentration. The ...

2002-08-01

243

Modification of ion-exchange resin composition for the removal of gadolinium from moderator system of 540 MWe PHWRs  

International Nuclear Information System (INIS)

Gadolinium removal during the first approach to criticality of TAPP-4 540 MWe reactor using mixed bed resin (strong acid cation resin and weak base anion resin) topped with strong acid cation exchange resin yielded IX column outlet pH of >6 during the first 6 h of run during which [Gd] decreased from 2.1 to 1 mg/kg. However, the main moderator system pH was between 5.0-5.5. Technical specification for pH of moderator is in the range 5.0-5.5 as long as Gd is present. This is to avoid any precipitation of Gd in the core and a pH of 5.8 or even a pH of 5.6 when carbonate is present is specified as the upper limit of the moderator system pH for this purpose. The situation of IX column outlet pH being #>=# 6 mixing with a system water having Gd results in local mixing zone pH in the range of 6- 5.4. In order to have an iso-pH regime (5-5.5) both with respect to the IX outlet as well as in the system, studies were conducted ...

2005-11-01

244

Light charged particles and intermediate mass fragments from the reactions 486, 550, 640, and 730 MeV [sup 86]Kr + [sup 63]Cu  

Energy Technology Data Exchange (ETDEWEB)

A study has been made of the reaction [sup 86]Kr + [sup 63]Cu at incident energies of 486, 550, 640, and 730 MeV. Measurements include cross sections, angular distributions, and energy spectra for light charged particles ([sup 1,2,3]H and [sup 4]He), intermediate mass fragments (IMF) (4 [le] Z [le] 17), and heavy fragments (Z [ge] 18). Coincidences between light charged particles and between particles and fragments have been measured to obtain cross sections, energy spectra, and angular distributions. Statistical model analysis of the energy spectra for [sup 1]H and [sup 4]He detected in coincidence with the fragments has allowed estimation of [sup 1]H and [sup 4]He multiplicities associated with the evaporation residues, fragments, and composite nuclei prior to scission. A comparison of cross sections, energy spectra, angular distributions, and particle multiplicities for these matched entrance channels has provided the means for a detailed test of the Bohr Independence Hypothesis. ...

1992-01-01

245

Geology And Radioactivity of Gabal Halal, Northern Sinai, Egypt  

International Nuclear Information System (INIS)

Gabal Ralal is one of the major asymmetrical doubly- plunging anticlinal fold belts (50 Km length) related to the Syrian Arc System in northern Sinai, Egypt. The exposed rock units at Gabal Ralal range from Cretaceous to Quaternary and are divided into eight formations which are from base to top: Malha, Ralal, Wata, Themed, Sudr, Beida, Egma and Quaternary wadi deposits. The image processing is applied using Landsat-7 satellite data to discriminate structure and lithology for defining the horizons of the radioactive anomalies of each rock unit. The extracted structural lineaments, using Ge Analyst-PCl package, from digital ETM data showed that the main structural trends are NE-SW and NW-SE normal faults which originated as extensional fractures with lateral dip-slip displacement. The axial trace of Gabal Ralal fold is curved and plunging to Wand SW directions while the northeastern part (Gabal Dalfa) is plunging to NE direction. The use of remote sensing data and ...

246

Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel  

Energy Technology Data Exchange (ETDEWEB)

AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water reactors (PWRs) ...

2008-07-01

247

The effect of perinatal "6"0Co gamma radiation on brain weight in beagles  

International Nuclear Information System (INIS)

Beagle dogs were given single, whole-body "6"0Co gamma-radiation exposures at one of three prenatal (8, 28, or 55 days postcoitus) or three postnatal (2, 70, or 365 days postpartum) ages to evaluate the relative radiosensitivity of various stages of brain development. A total of 387 dogs received mean doses ranging from 0.16 to 3.83 Gy, and 120 dogs were sham-irradiated. Groups of dogs were sacrificed at preselected times from 70 days to 11 years of age. Brain weight decreased significantly with increasing dose in dogs irradiated at 28 or 55 days postcoitus or at 2 days postpartum. Irradiations at 28 days postcoitus were dramatically more effective in causing a reduction in brain weight than those at 55 days postcoitus or 2 days postpartum. Among dogs given 1.0 Gy or more and followed for up to 4 years, there was a radiation effect evident at all three sensitive exposure ages. Among dogs given lower doses and followed for ...

248

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. This is due to the low ...

2002-03-01

249

Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante  

Energy Technology Data Exchange (ETDEWEB)

The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in ...

2006-07-01

250

Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects  

Energy Technology Data Exchange (ETDEWEB)

Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...

1996-12-31

251

Combined therapy of localized Ewing's sarcoma of bone: Analysis of results in 100 patients  

International Nuclear Information System (INIS)

From 1979 to 1986, 182 patients with biopsy proven diagnosis of Ewing's sarcoma of bone were observed. One hundred of the 182 patients (72 males, 28 females, median age 15.8 years) with localized disease and no previous treatment were treated with chemotherapy (VCR, ADM, CTX, D-ACT) for 15-18 months. Local treatment was radiotherapy (42 patients), surgery (31 patients), or a combination of both (27 pts). Radiation doses ranged from 45 to 64 Gy given with conventional fractionation. Median follow-up was 51.2 months (24-106). Overall and disease-free survival were, respectively, 58.7 and 42.6%. Resected patients tended to have a better local control (Surgery 93.6%, Surgery + Radiation therapy 92.6%, Radiation therapy 69.1%). Disease-free survival was significantly related to the volume of the primary tumor (bulky: 33.2%, not-bulky: 57.7%), to site (extremities 54.6%, central sites 16.6%, other sites ...

252

Calculated doses from inhaled transuranium radionuclides and potential risk equivalence to whole-body radiation  

International Nuclear Information System (INIS)

The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable size range, a useful ...

1975-11-17

253

Shellfish depuration by gamma irradiation: Final report for the period October 1, 1985-September 30, 1986  

International Nuclear Information System (INIS)

Irradiation of live bivalve molluscs is a promising new technique to reduce the public health threats of viral and bacterial pathogens in the consumption of raw shellfish. In studies conducted within the past year, live hardshelled clams and oysters were innoculated with Simian Rotavirus SA-11, Poliovirus I, and Hepatitis-A virus and treated with gamma ray ionizing radiation from University of Lowell/DOE 800,000 Curie "6"0Co source over a dose range of 0.5--10 kiloGray (50--1000 kilorad) to determine the effectiveness of the process in eliminating viral activity and thus easing the potential viral health threats associated with uncooked bivalves. Two viral strains, SA-11 and Poliovirus I, were employed as models to perfect laboratory technique and to estimate the most appropriate range of dose exposures necessary for optimal inactivation of the infectious pathogen, Hepatitis A. Post-irradiation survivorship of the oysters ...

254

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

256
257

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

258

Proceedings of a specialist meeting on regulatory approaches for the control of environmental residues containing naturally occurring radioactive material. Working material  

International Nuclear Information System (INIS)

Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic consequences. The ...

2002-09-23

259

Aspiration cover for the loading site of a belt conveyer  

Energy Technology Data Exchange (ETDEWEB)

An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.

1982-01-01

260

Salt decontamination demonstration test results  

International Nuclear Information System (INIS)

The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less than 10"3 d/m/ml versus a goal of less than ...

261

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal ...

2007-04-07

262

Origin of {gamma}-rays from young open clusters  

Energy Technology Data Exchange (ETDEWEB)

The young open cluster Berkeley 87 was predicted to be associated with the COS B {gamma}-ray source 2CG 075+00 on the basis of the experimental evidence of the presence of a shock front around the Wolf - Rayet star ST3 placed in the inner part of the cluster. The CGRO phase-1 data confirm this identification. Protons accelerated at the shock boundary can produce {pi} deg. via p-p interactions and then {gamma}-rays. With the measured flux F{sub {gamma}} (E > 100 MeV) {approx_equal} 9x10{sup -7} ph cm{sup -2} s{sup -1} and the power-law proton spectrum with spectral index {gamma} = 2, the cosmic-ray-energy-density in the inner part ({approx} 0.8 pc radius) of Berk 87 is about 100 times greater than that in the vicinity of the Earth. We have calculated {gamma}-ray spectra expected from the decay of {pi}{sup d}eg. produced in p-p interactions. The spectra have been normalized to the observed flux of Berk 87 by using different input proton spectra. The comparison of these normalized ...

1996-08-01

263

Measurement of the cosmic-ray antiproton flux and a search for an antihelium  

Energy Technology Data Exchange (ETDEWEB)

A balloon-borne instrument has measured the cosmic-ray antiproton flux between 130 and 320 MeV and searched for antihelium between 130 and 370 MeV per nuclear. These particles were selected from the background of normal-matter cosmic rays by combining a selective trigger with a detailed spark chamber visualization of each recorded event. Antiprotons are identified by their characteristic annihilatin radiation. Residue from background processes meeting the selection criteria is small. The observed 14 antiprotons yield a measured differential flux of 1.7 +- 0.5 x 10/sup -4/ antiprotons m/sup -2/ sr/sup -1/ s/sup -1/ MeV/sup -1/ at the top of the atmosphere. The corresponding antiproton/proton ratio is 2.2 +- 0.6 x 10/sup -4/,, only slightly smaller than the ratio observed by other experiments at higher energies. Thus the antiprotons have a spectral shape similar to the protons, at least down to about 100 MeV. The expected flux of these particles can be calculated ...

1981-09-15

264

Luminescence geochronology and evaluation of the environmental dose rate for the Neanderthal deposits at Vindija Cave (Northern Croatia)  

International Nuclear Information System (INIS)

Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at Vindija Cave, a key archaeological site in central Europe that contains a 12 m-thick ...

2008-04-13

265

Extratropical Forcing of Convectively Coupled Kelvin Waves during Austral Winter.  

Science.gov (United States)

Observations are presented that link extratropical Rossby wave disturbances excited in the Southern Hemisphere subtropical jet to the initiation of convectively coupled Kelvin waves in the Pacific intertropical convergence zone (ITCZ) during austral winter. A baroclinic, zonal wavenumber 6, eastward-propagating Rossby wave train in the subtropical jet turns northeastward in the vicinity of Australia, inducing upper tropospheric divergence and vertical motion fields that spread equatorward and induce cloudiness anomalies in the Tropics. Lower tropospheric pressure surges excited from the extratropics also induce Kelvin wave-like geopotential height and temperature anomalies at the surface, providing additional lower tropospheric convergence and vertical motion forcing. The tropical outgoing longwave radiation (OLR) and circulation fields propagate eastward in tandem with the extratropical Rossby wave train at approximately 17 m s-1. Kelvin wave ...

2003-02-01

266

Wing-surface-jet interaction characteristics of an upper-surface ...  

Science.gov (United States)

Engine flow simulation was provided by four separately mounted air ejectors connected to a high-pressure air supply. The engine nacelle center lines were ...

267

UARS Particle Environment Monitor (PEM) Level 3AT - Mirador - NASA  

Science.gov (United States)

May 11, 2011 ... The Particle Environment Monitor (PEM) on NASA's Upper Atmosphere Research Satellite (UARS) measures the type, amount, energy, and ...

268

UARS PEM Level 2 VMAG AC - Mirador - NASA  

Science.gov (United States)

May 11, 2011 ... The Particle Environment Monitor (PEM) on NASA's Upper Atmosphere Research Satellite (UARS) measures the type, amount, energy, and ...

269

Numerical Simulation of Cirrus Clouds - Fire Case Study and ...  

Science.gov (United States)

... being pulled out of water, the movement is restricted ... This heating depended on the particle size ... hydrometeor injection into the upper tropopause. ...

1991-08-12

270

MAIN RESULTS OF ATMOSPHERIC FINE STRUCTURE PARAMETER OBSERVATION ...  

Science.gov (United States)

results of motion energy spectral density measurements in the upper atmosphere for the time interval of 5 minutes to 12 hours, in ...

271

CHANEXTDFS - Chandra Extended Deep Field South Survey Point Source ...  

Science.gov (United States)

Jan 25, 2006 ... Source positions are determined using matched-filter and centroiding .... The upper 1-sigma statistical error in the full-band counts. ...

272

Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations  

International Nuclear Information System (INIS)

This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in pearl oyster, gulfweed and cuttlefish were ...

2004-05-01

273

Local thermodynamic equilibrium and related metrological issues involving collisional-radiative model in laser-induced aluminum plasmas  

Energy Technology Data Exchange (ETDEWEB)

We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al{sup 0}, Al{sup +} and Al{sup ++}). The calculations were carried for stationary plasmas, with input parameters (n{sub e} and T{sub e}) ranging respectively between 10{sup 13-18} cm{sup -3} and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to ...

2009-10-15

274

Local thermodynamic equilibrium and related metrological issues involving collisional-radiative model in laser-induced aluminum plasmas  

International Nuclear Information System (INIS)

We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al0, Al+ and Al++). The calculations were carried for stationary plasmas, with input parameters (ne and Te) ranging respectively between 1013-18 cm-3 and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to stand, the Boltzmann plot outputs of this ...

2009-10-01

275

Dose and temporary characteristics of the changes in the amount of nucleic acids in leucocytes of irradiated rats  

International Nuclear Information System (INIS)

An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early dose-dependent changes in NA content. The nature of their post-irradiation dynamics also depended on the ...

276

A study on the recovery of radiation hardening of PWR pressure vessel steel using microhardness and positron annihilation  

International Nuclear Information System (INIS)

A post-irradiation annealing study was conducted with use of reactor pressure vessel(RPV) steel A533B C1.1 base metal irradiated to a dose of 4.84x10"1"8 n/cm"2 at about 380 deg C. Microhardness and positron annihilation (PA) methods were used to obtain better understanding of the recovery of radiation hardening. Isochronal anneal experiments indicated that two recovery processes occur during annealing of irradiated specimens. The first recovery process occurs in the temperature of 280-305 deg C. The variations of Ip, Iw and R parameters indicated that the formation of vacancy clusters by vacancy aggromeration and the annihilation parameters measured indicated that the dissolution of carbon atoms decorated around vacancy-type defects and possible precipitates, and the annihilation of monovacancies give rise to the second recovery process. It was further indicated that radiation anneal hardening (RAH) in the range of 305-405 ...

277

Repeat Stereotactic Radiosurgery for Acoustic Neuromas  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second ...

2010-02-01

278

Shelf-life extension and decontamination of fish fillets (Trachurus picturatus murphyi and Mugil cephalus) and shrimp tails (Penaeus vannamei) inoculated with toxigenic Vibrio cholerae O1 El Tor using gamma radiation  

International Nuclear Information System (INIS)

The radiation decimal reduction dose (D_1_0) of toxigenic Vibrio cholerae O1 El Tor, Inaba was determined in vitro (0.13 kGy) and in inoculated fresh fillets of saurel (Trachurus picturatus murphyi) (0.12 kGy) and another Pacific fish species known in Peru as ''lisa'', Mugil cephalus (0.13 kGy), both of which are frequently consumed raw in ''ceviche''. The D_1_0 value was similarly determined in tails of the shrimp species Penaeus vannamei (0.13 kGy). In a second phase of the study, radiation doses in the range 1.0-4.0 kGy were evaluated for use in microbiological shelf-life extension of the selected seafood, and for adverse effects on various sensory attributes (appearance, odor, flavor, and texture). A dose of 1.0 kGy doubled the microbiological shelf-life of fish fillets during post-irradiation storage at 0-1 deg. C to approximately 30 days. This dose was deemed optimal also for preserving all sensory characteristics ...

2001-04-01

279

Radiotherapy in Ewing's sarcoma and PNET of the chest wall: results of the trials CESS 81, CESS 86 and EICESS 92  

International Nuclear Information System (INIS)

Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...

1998-12-01

280

Isolating the effect of radiation-induced segregation in irradiation-assisted stress corrosion cracking of austenitic stainless steels  

International Nuclear Information System (INIS)

Post-irradiation annealing was used to help identify the role of radiation-induced segregation (RIS) in irradiation-assisted stress corrosion cracking (IASCC) by preferentially removing dislocation loop damage from proton-irradiated austenitic stainless steels while leaving the RIS of major and minor alloying elements largely unchanged. The goal of this study is to better understand the underlying mechanisms of IASCC. Simulations of post-irradiation annealing of RIS and dislocation loop microstructure predicted that dislocation loops would be removed preferentially over RIS due to both thermodynamic and kinetic considerations. To verify the simulation predictions, a series of post-irradiation annealing experiments were performed. Both a high purity 304L (HP-304L) and a commercial purity 304 (CP-304) stainless steel alloy were irradiated with 3.2 MeV protons at 360 deg. C to doses of 1.0 and 2.5 dpa. Following irradiation, post-irradiation anneals were performed at ...

2002-04-01

281

Biological Effects after Prenatal Irradiation  

International Nuclear Information System (INIS)

A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental retardation after ...

282

Benchmarks and models for 1-D radiation transport in stochastic participating media  

Energy Technology Data Exchange (ETDEWEB)

Benchmark calculations for radiation transport coupled to a material temperature equation in a 1-D slab and 1-D spherical geometry binary random media are presented. The mixing statistics are taken to be homogeneous Markov statistics in the 1-D slab but only approximately Markov statistics in the 1-D sphere. The material chunk sizes are described by Poisson distribution functions. The material opacities are first taken to be constant and then allowed to vary as a strong function of material temperature. Benchmark values and variances for time evolution of the ensemble average of material temperature energy density and radiation transmission are computed via a Monte Carlo type method. These benchmarks are used as a basis for comparison with three other approximate methods of solution. One of these approximate methods is simple atomic mix. The second approximate model is an adaptation of what is commonly called the Levermore-Pomraning model and ...

2000-08-21

283

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

284

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

286

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

288

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

289

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

290

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

291

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

292

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

293

Ultraviolet radiation for the sterilization of contact lenses  

Energy Technology Data Exchange (ETDEWEB)

Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials ...

1990-10-01

294

Ultraviolet radiation for the sterilization of contact lenses  

International Nuclear Information System (INIS)

Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials ...

295

Studies on radiation induced changes in bovine hemoglobin type A  

International Nuclear Information System (INIS)

In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO_2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction and an increase of affinity for oxygen. Differences observed in oxygen-dissociation curves seem to be correlated with the radiation induced destruction of amino acid ...

296

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of ...

1990-03-01

297

Radiation Chemistry of Aqueous Solutions Related to Nuclear Reactor Systems and Spent Fuel Management  

International Nuclear Information System (INIS)

In this thesis the rate constants for a number of radical reactions in aqueous solution have been studied in a wide temperature range. The reactions of H with H_2O_2, OH and HO_2 and the reactions of HO_2 with OH, Fe"2"+ and Cu"2"+ have been studied. For each reaction rate constants have been determined as a function of temperature using the technique of high temperature, high pressure (HTP) pulse radiolysis. The rate constants were obtained by fitting a kinetic computer model to the experimental data. From an Arrhenius plot the activation energy of each reaction was determined. The data determined in this way are important for modeling of radiolysis in nuclear light water reactors. A previously developed model for calculation of the effect of water radiolysis products on oxidation and dissolution of spent nuclear fuel has been improved. In the new model, called TraRaMo, simultaneous transport by diffusion and chemical reactions induced by radiolysis can be ...

2003-01-01

298

Production of wood plastic properties using gamma radiation as a polimerization agent  

International Nuclear Information System (INIS)

The properties of wood plastic composites (WPC) based on Pinus Radiata D. Don impregnated with methylmethacrylate and subsequently polymerized with gamma radiation were studied. Different systems of impregnation were utilized, in order to obtain partial and shell loads. The minimum irradiation dose uses was 16 kGy. The following tests were made to the material: static bending, compression strenght parallel to grain, hardness, sheer strength, toughness, water absorption, dimensional stability and flame propagation index. To evaluate the testing, the results of the samples were separated according final density in the ranges: R_1 = 429-483 kg/m3 (without treatment); R_2 = 500-650 kg/m3 and R3 = 651-850 kg/m3. In general, the best results were obtained for samples of high density. The most important results were achieved for dimensional stability, water absorption and hardness. (Author).

1984-01-01

299

Possible preparation of wood-plastic materials based on unsaturated polyester resins and methyl metacrylate, by radiation and chemical methods in combination  

Energy Technology Data Exchange (ETDEWEB)

The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture ...

1982-04-01

300

Possible preparation of wood-plastic materials based on unsaturated polyester resins and methyl metacrylate, by radiation and chemical methods in combination  

International Nuclear Information System (INIS)

The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture ...

1982-01-01

301

Parametric study of radiative cooling of solid antihydrogen. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and hydrogen's thermal-impulse response time ...

1989-03-01

302

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...

303

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

304

Laser eye protection. Interim report, July 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against both nuclear and laser radiation. At the ...

1990-01-01

305

Jacobi stability of the vacuum in the static spherically symmetric brane world models  

International Nuclear Information System (INIS)

We analyze the stability of the structure equations of the vacuum in the brane world models, by using both the linear (Lyapunov) stability analysis, and the Jacobi stability analysis, the Kosambi-Cartan-Chern theory. In the brane world models the four-dimensional effective Einstein equations acquire extra terms, called dark radiation and dark pressure, respectively, which arise from the embedding of the three-brane in the bulk. Generally, the spherically symmetric vacuum solutions of the brane gravitational field equations have properties quite distinct as compared to the standard black hole solutions of general relativity. We close the structure equations by assuming a simple linear equation of state for the dark pressure. In this case the vacuum is Jacobi stable only for a small range of values of the proportionality constant relating the dark pressure and the dark radiation. The unstable trajectories on the brane behave ...

2008-05-15

306

Interaction of free fatty acids with the erythrocyte membrane as affected by hyperthermia and ionizing radiation  

Energy Technology Data Exchange (ETDEWEB)

The interference of hyperthermia and ionizing radiation, respectively, with the effects of capric (10:0), lauric (12:0), myristic (14:0), oleic (cis-18:1) and elaidic (trans-18:1) acids on the osmotic resistance of human erythrocytes was investigated. The results are summarized as follows: (A) not only at 37 degrees, but also at 42 and 47{degrees}C lauric acid (12:0) represents the minimum chain length for the biphasic behaviour of protecting against hypotonic hemolysis at a certain lower concentration range and hemolysis promotion at subsequent higher concentrations; (B) with increasing temperatures the protecting as well as the hemolytic effects occur at lower concentrations of the fatty acids; (C) the increase of temperature promotes the extent of hemolysis and reduces the extent of protection against hypotonic hemolysis; (D) Gamma-irradiation of erythrocytes selectively affects the concentration of oleic acid at which maximum protection ...

1990-04-01

307

Influence of the circadian rhythm in cell division on radiation-induced mitotic delay in vivo  

Energy Technology Data Exchange (ETDEWEB)

Mitotic delay is described as a classical response to radiation; however, circadian rhythmicity in cell division in vivo has not been considered by many authors. The present study investigated the relation between fluctuations reported as mitotic delay and recovery in vivo and circadian oscillations in mitotic index in mouse corneal epithelium. One aspect involved single doses (approximately 600 rad) given to mice at different circadian stages. The normal circadian rhythm in cell division was never obliterated. Inhibition of mitosis was evident but unpredictable, ranging from 6 to 15 hr after irradiation. Recovery was evident only during the daily increase in mitotic index of controls. The classical interpretation of recovery from mitotic delay may be in an in vitro phenomenon not reflecting in vivo responses, which are apparently strongly circadian stage dependent. The second portion of the study demonstrated a dose-response effect on length ...

1982-01-01

308

Environmental data for sites in the National Solar Data Network  

Energy Technology Data Exchange (ETDEWEB)

The environmental data for the NSDN are presented in the form of tables for each solar site. The solar sites are grouped into 12 zones, each of which consists of several adjacent states. The solar energy sites are in alphabetical sequence within each zone. The tables provide available meteorological data for reporting sites in the NSDN as follows: Insolation - the insolation table presents the total, diffuse, direct, maximum, and extra-terrestrial radiation for the solar site. It also shows the ratio of total extra-terrestrial radiation, as a percent. Temperature - the temperature table gives the average, daytime, nightime, maximum, minimum and inlet-water temperatures for the solar site. Additional tables are presented for some of these NSDN sites, supplying either wind or relative humidity data, or both. Wind - all of the passive and some of the active solar sites are equipped with wind sensors. These provide information for two wind tables. ...

1980-12-01

309

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

310

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...

2010-10-01

311

A radiation hardening model of 9%Cr-martensitic steels including dpa and helium  

International Nuclear Information System (INIS)

This paper provides a physically-based engineering model to estimate radiation hardening of 9%Cr-steels under both displacement damage (dpa) and helium. The model is essentially based on the dispersed barrier hardening theory and the dynamic re-solution of helium under displacement cascades but incorporating a number of assumptions and simplifications [Trinkaus, J. Nucl. Mater. 318 (2003) 234-340]. As a result, the kinetics of the damage accumulation kept fixed, its amplitude is fitted on one experimental condition. The model was rationalized on an experimental database that mainly consists of ?9%Cr-steels irradiated in the range of 50-600 deg. C up to 50 dpa and with a He-content up to 5000 appm. The test temperature effect is taken into account through a normalization procedure based on the change of the Young's modulus and the anelastic deformation that occurs at high temperature. Despite the large experimental scatter, inherent to the ...

2009-04-30

312

THE M-#sigma# AND M-L RELATIONS IN GALACTIC BULGES, AND DETERMINATIONS OF THEIR INTRINSIC SCATTER  

International Nuclear Information System (INIS)

We derive improved versions of the relations between supermassive black hole mass (M _B_H) and host-galaxy bulge velocity dispersion (#sigma#) and luminosity (L; the M-#sigma# and M-L relations), based on 49 M _B_H measurements and 19 upper limits. Particular attention is paid to recovery of the intrinsic scatter (#epsilon#_0) in both relations. We find log(M _B_H/M _s_u_n) = #alpha# + #beta#log(#sigma#/200 km s"-"1) with (#alpha#, #beta#, #epsilon#_0) = (8.12 #+-# 0.08, 4.24 #+-# 0.41, 0.44 #+-# 0.06) for all galaxies and (#alpha#, #beta#, #epsilon#_0) = (8.23 #+-# 0.08, 3.96 #+-# 0.42, 0.31 #+-# 0.06) for ellipticals. The results for ellipticals are consistent with previous studies, but the intrinsic scatter recovered for spirals is significantly larger. The scatter inferred reinforces the need for its consideration when calculating local black hole mass function based on the M-#sigma# relation, and further implies that there may be substantial selection bias in ...

2009-06-10

313

Submarine tsunamigenic landslides at Stromboli Volcano: characterization and estimation of recurrence time  

Science.gov (United States)

Seafloor mapping and morphometric analysis of landslide scars can provide useful insights for marine geo-hazard assessment, as demonstrated by several studies performed on different geological settings. The availability of high-resolution multibeam bathymetry and long-range side scan sonar data on the submarine portions of Stromboli Volcano allow us to map and characterize the main mass-wasting features that affect, on the whole, about the 90% of its submarine extension. In particular, two main kinds of tsunamigenic landslides have been recognized and analyzed. Large-scale sector collapses (Fig. 1) are catastrophic events that mobilize 1-2 cubic kilometers of material, generating huge tsunami waves that may affect Stromboli and propagate in surrounding areas; related hazard is not very high, as they show recurrence periods of some (or more) thousand years. Conversely, medium-scale landslides are more hazardous, as they occur at higher frequency with respect to the ...

2010-12-01

314

Reduction of RF-sheaths potentials by compensation or suppression of parallel RF currents on ICRF antennas  

International Nuclear Information System (INIS)

Radio frequency (RF) sheaths are suspected of limiting the performance of present-day ion cyclotron range of frequencies (ICRFs) antennas over long pulses and should be minimized in future fusion devices. Within the simplest models, RF-sheath effects are quantified by the integral VRF = ? E|| ? dl where the parallel RF field E|| is linked with the slow wave. On 'long open field lines' with large toroidal extension on both sides of the antenna it was shown that VRF is excited by parallel RF currents j|| flowing on the antenna structure. In this paper, the validity of this simple sheath theory is tested experimentally on the Tore Supra (TS) ITER-like antenna prototype (ILP), together with antenna simulation and post-processing codes developed to compute VRF. The predicted poloidal localization of high-|VRF| zones is confronted to that inferred from experimental data analysis. Surface temperature distribution on ILP front face, as well as ILP-induced modifications of ...

2010-02-01

315

Recovery and reconnaissance of the Leading Creek watershed, Meigs County, Ohio, following a dewatering of Meigs number-sign 31 coal mine  

International Nuclear Information System (INIS)

A database has been developed before and after the dewatering of the Meigs number-sign 31 deep coal mine in Meigs County, Ohio, three years ago. This strategy was to compare potential recovery of the watershed in the mainstem of Leading Creek as well as to reconnaissance the tributaries for point-source input into the creek. After the dewatering process, #approx# half of the 31-mile Leading Creek mainstem received a discharge of conductivity, low pH, high metals (iron, manganese, copper, aluminum), and total suspended solids (TSS). Most forms of aquatic life in the creek were depleted in the impacted areas, but recovery has been encouraging. Relative fish abundance has returned to pre-event levels, while benthic macroinvertebrates show recovery in two key stream segments. Reconnaissance of the watershed indicated that the system is uniquely segregated with high sedimentation from agricultural input in the upper half and abandoned mined land (AML) discharges in the ...

1996-11-17

316

Preliminary Simulations of CO2 Transport in the Dolostone Formations in the Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes preliminary 2-D reactive-transport simulations on the injection, storage and transport of supercritical CO{sub 2} in dolostone formations in the Ordos Basin in China. The purpose of the simulations was to evaluate the role that basin heterogeneity, permeability, CO{sub 2} flux, and geochemical reactions between the carbonate geology and the CO{sub 2} equilibrated brines have on the evolution of porosity and permeability in the storage reservoir. The 2-D simulation of CO{sub 2} injection at 10{sup 3} ton/year corresponds to CO{sub 2} injection at a rate of 3 x 10{sup 5} ton/year in a 3-D, low permeable rock. An average permeability of 10 md was used in the simulation and reflects the upper range of permeability reported for the Ordos Basin Majiagou Group. Transport and distribution of CO{sub 2} between in the gas, aqueous, and solid phases were followed during a 10-year injection phase and a 10-year post injection phase. ...

2009-04-30

317

Initial review of the treatment operations at the Installation Logistics Center, Fort Lewis, Washington  

Energy Technology Data Exchange (ETDEWEB)

An initial review was conducted of the current treatment operations for remediation of groundwater contaminated with trichloroethene (TCE) at the Fort lewis Logistics Center. Results from this review indicate the two pump-and-treat systems are effectively containing the TCE plume within the upper unconfined aquifer (Vashon Drift). However, mass balance calculations show the existing treatment systems alone will not accomplish the remedial action objective of cleaning up the aquifer to drinking water standards within 30 years as specified in the Record of Decision (ROD). This conclusion is based on the estimated mass of TCE at the source term (51,000 kg), the calculated mass of TCE in the aquifer (4,900 kg), and the removal rate of the pump-and-treat systems that currently ranges from 324 to 667 kg of TCe per year. Four areas within the TCE plume have been identified where enhancements could be made to the existing treatment operations. These ...

1998-07-01

318

High resolution sequence stratigraphy of Miocene deep-water clastic outcrops, Taranaki coast, New Zealand  

Energy Technology Data Exchange (ETDEWEB)

Approximately 700m of deep water clastic deposits of Mt. Messenger Formation are superbly exposed along the Taranaki coast of North Island, New Zealand. Biostratigraphy indicates the interval was deposited during the time span 10.5-9.2m.y. in water depths grading upward from lower bathyal to middle-upper bathyal. This interval is considered part of a 3rd order depositional sequence deposited under conditions of fluctuating relative sea-level, concomitant with high sedimentation rates. Several 4th order depositional sequences, reflecting successive sea-level falls, are recognized within the interval. Sequence boundaries display a range of erosive morphologies from metre-wide canyons to scours several hundred metres across. All components of a generic lowstand systems tract--basin floor fan, channel-levee complex and progading complex--are present in logical and temporal order. They are repetitive through the interval, with the relatively ...

1995-08-01

319

Galactic evolution of D and "3He including stellar production of "3He  

International Nuclear Information System (INIS)

New stellar models which track the production and destruction of "3He (and D) have been evolved for a range of stellar masses (0.65#<=#M/M_c_i_r_c_l_e_-_d_o_t#<=#100), metallicities (0.01#<=#Z/Z_c_i_r_c_l_e_-_d_o_t#<=#1), and initial (main-sequence) "3He mass fractions (10"-"5#<=#X_3_,_M_S#<=#10"-"3). Armed with the "3He yields from these stellar models we have followed the evolution of D and "3He using a variety of chemical evolution models with and without infall of primordial or processed material. Production of new "3He by the lower mass stars overwhelms any reasonable primordial contributions and leads to predicted abundances in the presolar nebula and/or the present interstellar medium in excess of the observationally inferred values. This result, which obtains even for zero primordial D and "3He, and was anticipated by Rood, Steigman, ampersand Tinsley is insensitive to the choice of chemical evolution model; it is driven by the large "3He ...

320

Development of lead-free copper alloy-graphite castings. Technical report, January 1994--December 1994  

Energy Technology Data Exchange (ETDEWEB)

Water model experiments were conducted to develop a two-stage stirring method for obtaining higher yields and a more uniform distribution of graphite particles in copper alloys. This was followed by several melts for synthesis of copper-graphite alloys in which Ti was used as a wetting agent to improve the wettability of graphite in the copper melt. In the first stage, a vortex method was employed to facilitate the addition of graphite particles into the copper melt. In the second stage, a specially designed stirrer was used for uniform particle distribution while avoiding the formation of vortex in the melt. The two-stage stirring was found to considerably improve the recovery of graphite, over those obtained with the prior practice of single-stage stirring and resulting in a more uniform particle distribution. In addition, graphite recoveries increased with increasing Ti content in the range investigated. Floatation, fluidity, and directional solidification ...

1995-07-01

321

Coal rank and coalbed methane potential of Cretaceous/Tertiary coals in the Canadian Rocky Mountain Foothills and adjacent Foreland. 1: Hinton and Grand Cache areas, Alberta  

Energy Technology Data Exchange (ETDEWEB)

The coal rank, coal distribution, and coalbed methane of four major coal zones in the Hinton and Grande Cache areas of Alberta were investigated. Coal rank in the study area ranges from subbituminous and high volatile C bituminous at surface for the Upper Cretaceous/Tertiary coal measures and semianthracite for the Lower Cretaceous Luscar Group in the Alberta Syncline. In the Rocky Mountain Foothills, maximum cumulative coal thicknesses occur in the Smoky River, Cadomin-Luscar, and Coal Valley coalfields. Cumulative coal thicknesses generally decrease east of the deformed belt; however, coal isopach maps indicate local cumulative coal thicknesses in excess of 25 m. A regional coalbed methane assessment for strata east of the deformed belt shows favorable coalbed methane adsorption capacities in Luscar Group coals. These coals occur, however, at depth levels [gt]2500 m. In contrast, Brazeau and Coalspur Formation coals occur at favorable depth ...

1994-12-01

322

Coal compilation project - Pierre Greys Lakes NTS 83E/15  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of the pilot Coal Compilation Project is to provide coal resource maps to stimulate and support industry exploration programs, and assist government in matters of resource management. An essential feature of the program is the use of cost effective Geoscience Information System (GSIS) technology that allows the database and various thematic maps to be analyzed, updated, and displayed with complete flexibility at any scale. This report describes the main features (geology, resource management, coal occurrences, etc.) of the study area, mapsheet NTS 83E/15 (Pierre Greys Lakes), and includes a copy of the 1:50,000 scale map produced. The study area is located in west-central Alberta and contains coal measures deposited amid thick successions of sandstones, siltstones, shales and conglomerates. These coal-bearing sequences are part of the Lower Cretaceous Luscar Group, Upper Cretaceous Brazeau Formation and Paleocene Coalspur Formations. Within the ...

1990-01-01

323

Clinical studies on cancer of the tongue  

Energy Technology Data Exchange (ETDEWEB)

Thirty-nine previously untreated patients with squamous cell carcinoma of the tongue were treated by irradiation or a combination of irradiation and surgery, with or without chemotherapy, between January 1971 and December 1980. All of the patients had a follow-up period of at least nine years. Twenty-two patients were men and 17 were women. The average age was 50.1 years, with a range of 30 to 74 years. The absolute five-year survival rate was 82.1% and the cumulative ten-year survival rate 76.9% for these 39 patients. Cervical node metastases were clinically found on admission in 14 patients whose five-year survival rate was 64.3%, whereas it was 92.0% for 25 patients without metastasis. The absolute five-year survival rate decreased from 92.3% for patients with stage I lesions to 90.9%, 87.5% and 42.9% for those with stage II, stage III and stage IV lesions, respectively. Most of the patients received external irradiation and intraoral electron beam therapy. ...

1990-12-01

324

Carbon isotope stratigraphy of the upper Kharaib and Shuaiba formations: Implications for the Early Cretaceous evolution of the Arabian Gulf Region  

Energy Technology Data Exchange (ETDEWEB)

The carbon isotope profiles of shallow-marine carbonates from the Barremian-Aptian Kharaib and Shuaiba formations of the Arabian Gulf region range between 0.5 and 7{per_thousand} {delta}{sup 13}C PDB (Peedee belemnite). Systematic variations can be correlated with isotope profiles reported from Tethyan pelagic limestone sequences. The detailed correspondence between the isotopic signature of the relatively well-dated pelagic limestones and the poorly dated shallow-water limestones from the Arabian Gulf region suggests that global marine carbon isotope changes apparently affected deep-sea and shallow-water carbonate sediments similarly and at a similar time resolution. Although oxygen isotopes have been reset during diagenesis, carbon isotopes appear to have maintained their primary marine signature through time. No evidence has been found to connect carbon isotope trends to subaerial exposure or later meteoric diagenesis. In combination with other data, the ...

1996-05-01

325

Monitoring of the Water Levels in the Wetlands of Fourmile Branch near the F and H Areas of SRS: January - December 2000  

Energy Technology Data Exchange (ETDEWEB)

In 2000, a network of twenty-three piezometers was used to measure hydraulic head in the water-table aquifer (Upper Aquifer Zone of the Upper Three Runs Aquifer, or UAZ of the UTRA) along the ground water outcrops (i.e. seeplines) near the F- and H-Areas.

2001-07-10

326

Determining the upper limit of Gamma_{ee} for the Y(4260)  

CERN Document Server

By fitting the R values between 3.7 and 5.0 GeV measured by the BES collaboration, the upper limit of the electron width of the newly discovered resonance Y(4260) is determined to be 240 eV at 90% C.L., together with the BABAR measurement on the product of Gamma_{ee} and BR(Y(4260) --> pi+pi- J/psi), this implies a large decay width of Y(4260) --> pi+pi- J/psi final states.

2006-01-01

327

Coolant stratification and its thermohydrodynamic specificity under natural circulation in horizontal steam generator collectors  

Energy Technology Data Exchange (ETDEWEB)

The experiments and the test facilities for the study of the stratification phenomenon in the hot plenum of reactor and the upper parts of the steam generator collectors in a nuclear power plant are described. The aim of the experiments was to define the conditions of the stratification initiation, to study the temperature field in the upper part, the definition of the characteristics in the stratification layer, and also to study the factors which cause the intensity of the stagnant volume cooling.

1997-12-31

328

Program plan for development of underground hydroelectric pumped storage technology  

Science.gov (United States)

The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, ...

1976-03-01

329

Evolution of the triangle zone in the Rocky Mountains Foothills near Coalspur, Central Alberta  

Energy Technology Data Exchange (ETDEWEB)

A triangle zone, which commonly occurs along the external margin of a foreland thrust and fold belt with a buried thrust front, is underlain by a subhorizontal, blind, foreland-verging thrust that ends against a foreland-dipping, hinterland-verging thrust. These contemporaneous thrusts, active towards the end of orogenesis, enclose an intercutaneous wedge that moved towards the foreland. During orogenesis, a triangle zone evolves through periodic replacement of faults bounding the active wedge. Replacements occur in cycles during each of which a lower fault tends to be replaced by one in a lower stratigraphic horizon, an upper fault by one farther away from the foreland. Each cycle ends with the lower fault moving to a younger horizon where it joins a new, more external upper fault. Near Coalspur, the triangle zone exposes the remnants of several wedges involving Upper Cretaceous and Palaeocene molasse. Most of these wedges ...

1987-08-01

330

Wave electromagnetic fields induced by instantaneous braking of charges  

International Nuclear Information System (INIS)

Exact expressions for wave electromagnetic fields during instantaneous braking of two differently charged discs uniformly moving in the opposite directions have been derived. Analysis of their properties has been made. It is shown that electromagnetic wave fields during instantaneous braking of charges have a tearing nature and the Umov-Poynting theorem in the integral form is realized only at a certain value of parameter #alpha# which determines charges rates at the moment of braking. The value of parameter #alpha# is in the ranges from 0.5 to #sq root#3/2. The wave field is formed already in the absence of motion of charged discs. It is a good example confirming the conclusion that in the case of nonstationary electromagnetic fields, performance of reaction force of the wave field can differ fram radiation energy.

331

Venus surface power and cooling systems  

British Library Electronic Table of Contents (United Kingdom)

A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...

2007-01-01

332

Treatment of hepatocellular carcinoma (HCC) with radiolabeled Lipiodol: a preliminary report  

Energy Technology Data Exchange (ETDEWEB)

Fatty acid esters such as Lipiodol or Ethiodol are known to selectively localize in vascular hepatocellular carcinomas (HCC), following intraarterial hepatic administration. Lipiodol was labeled with radioactive /sup 131/I and administered in 47 patients with HCC for both imaging and therapy. The short term preliminary results suggest radiolabeled Lipiodol is effective in eliminating ascites, shrinking the tumor by a high internal radiation dose, and in improving symptomatology of these tumors. In the future, /sup 90/Y, which is a stronger pure beta-emitter (maximum beta energy of 2.27 MeV, a half life of 64 h, and a maximum penetration or beta range of 11mm), than /sup 131/I will be used for more effective treatment of HCC.

1987-12-01

333

The impact of solar flares and magnetic storms on humans  

International Nuclear Information System (INIS)

Three classes of solar emanations, namely, photon radiation from solar flares, solar energetic particles, and inhomogeneities in the solar wind that drive magnetic storms, are examined, and their effects on humans and technological systems are discussed. Solar flares may disrupt radio communications in the HF and VLF ranges. Energetic particles pose a special hazard at low-earth orbit and above, where they can penetrate barriers such as spacesuits and aluminum and destroy cells and solid state electronics. Energetic solar particles also influence terrestrial radio waves propagating through polar regions. Magnetic storms may disturb the operation of navigation instruments, power lines and pipelines, and satellites; they give rise to ionospheric storms which affect radio communication at all latitudes. There is also a growing body of evidence that changes in the geomagnetic field affect biological systems. 3 refs.

334

The ground state well depth position R {sub m} of Van der Waals molecules and the spectral line shapes  

Energy Technology Data Exchange (ETDEWEB)

As the ground state potential curve is strongly related to spectral line shapes, the minumum position of the ground state potential is obtained from the experiemental absorption profile k({delta}{nu}, T) at high density of the radiating atoms. The temperature dependence of the absorption processes of Hg and Cd lines 253.65 and 326.1 nm, respectively perturbed by inert gases (Xe, Kr, Ar and Ne) had been carefully studied over a wide spectral range. Using the point of the maximum temperature dependence {delta}{nu} {sub m} in each case, we are able to calculate the position of the ground state potential R {sub m} using a simple formula.

2006-09-15

335

The duke XUV FEL storage ring facility  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present status and developments of the Duke storage ring facility. The Duke storage ring facility provides the unique combination of phase-locked light sources ranging from high power OK-4 XUV FEL to quasimonochromatic {gamma}-ray beam and IR/X-ray spontaneous radiation. The XUV OK-4 FEL, which is collaborative project with BlNP, Novosibirsk, is in operation since November, 1996. The OK-4 UV FEL is also used for production of nearly monochromatic {gamma}-ray s with tunable energy. We present the results of UV lasing with the OK4 FEL and selected results of its applications. We will discuss our future plans for extension of this source and status of the construction of dedicated used facility adjacent to the FEL building. (author)

1998-11-01

336

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

337

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

338

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

339

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

340

Radiation imposed limits on superconducting magnets: A data base for copper stabilizers  

Energy Technology Data Exchange (ETDEWEB)

Two of eight differently prepared copper stabilizer samples, previously irradiated in the RTNS-II at LLNL, the IPNS-1 and the BSR at ORNL, have been irradiated to a fluence of 1.33 /times/ 10/sup 22/ n/m/sup 2/ at RTNS-II. During the course of the irradiation the samples were periodically removed (without warming) for measurements of the transverse magnetoresistance and returned for continued irradiation. This experiment extends the range of neutron-irradiation-induced resistivity by a factor of five over the previous experiments. A simple model is developed which reproduces the magnetoresistance results of all the experiments to an accuracy of 2.5%. 13 refs., 6 figs.

1987-10-28

341

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

342

Photosynthesis responses to various soil moisture in leaves of Wisteria sinensis  

British Library Electronic Table of Contents (United Kingdom)

A study was conducted to determine the fitting soil moisture for the normal growth of two-year-old W. sinensis (Sims) Sweets by using gas exchange technique. Remarkable threshold values of net photosynthetic rate (Pn), transpiration rate (Tr) and water use efficiency (WUE) were observed in the W. sinensis leaves treated by various soil moisture and photosynthetic available radiation (PAR). The fitting soil moisture for maintaining a high level of Pn and WUE was in range of 15.3%?26.5% of volumetric water content (VWC), of which the optimal VWC was 23.3%. Under the condition of fitting soil moisture, the light saturation point of leaves occurred at above 800?mol?m?2?s?1, whereas under the condition of water deficiency (VWC, 11.9% and 8.2%) or oversaturation (VWC, 26.5%), the light saturatio...

2007-01-01

343

Personal nuclear accident dosimetry at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.

1996-09-01

344

Long-term mortality and cancer risk in irradiated rhesus monkeys. Interim report, 30 September 1983-15 July 1989  

Energy Technology Data Exchange (ETDEWEB)

Lifetime observations on a group of 358 rhesus monkeys indicate that life expectancy loss from exposure to protons in the energy range encountered in the Van Allen belts and solar proton events is influenced primarily by the dose rather than the energy of radiation. After 24 years, life expectancy losses from similar surface doses of low-LET (138-2300 MeV) and high-LET (32-55 MeV) protons are not significantly different, but the high-LET protons are associated with more deaths in the early years, while the low-LET protons contribute more to mortality in later years. In males, the most significant cause of life shortening is nonleukemia cancers.

1990-05-01

345

Interactions of SO{sub x} and NO{sub x} with soot  

Energy Technology Data Exchange (ETDEWEB)

Studies of the adsorption of oxides of sulfur and nitrogen, and their coadsorption, on black carbon in the form of n-hexane soot have been carried out by microgravimetry, EPR and FTIR spectroscopy over a wide range of experimental conditions. The mechanisms of adsorption of O{sub 2} and NO{sub 2} are entirely different, as reflected by adsorption isotherms, the behavior of carbon`s unpaired electrons, the spectral features of surface species formed, mass changes during adsorption-desorption cycles, and an essential lack of competition for surface sites. Significant effects of temperature, water, SO{sub 2} and NO{sub 2} concentration, O{sub 2}, simulated solar radiation, and the presence of trace metals, have been observed and interpreted.

1996-10-01

346

Immobilization of bacteria in microgel grafted onto macroporous polyethylene  

Energy Technology Data Exchange (ETDEWEB)

The development of 'Green Chemistry' requires new materials to replace the conventional organic chemistry by biological catalysts, to produce fine chemicals in an environmentally friendly manner. Microbial whole cells can be directly used as biocatalysts, providing a simple and cheap methodology since enzyme isolation and purification are avoided. High-density polyethylene (HDPE) is a very stable polymer though it can be activated by gamma radiation to induce grafting. Glycidyl methacrylate was grafted onto macroporous HDPE and PP in the range of 1-6%, proportional to the initial monomer concentration. Grafted polymers were further chemically modified with ethylenediamine to generate a cationic hydrogel of micron-size thickness onto the internal polymer surfaces. Modified polymers were able to immobilize Gram-positive and Gram-negative bacteria that can catalyze a chemical reaction as efficient as free cells do.

2010-03-15

347

Human climatic comfort within enclosing walls with varying strengths of infrared radiation reflection  

Energy Technology Data Exchange (ETDEWEB)

An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% saving in heating energy. (orig./BWI).

1985-06-01

348

Evapotranspiration estimation using the Landsat-5 Thematic Mapper image over the Gyungan watershed in Korea  

British Library Electronic Table of Contents (United Kingdom)

Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...

2011-01-01

349

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-12-01

350

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

International Nuclear Information System (INIS)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-01-01

351

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).

1993-06-01

352

Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).

1991-01-01

353

ESR dating of fault rocks  

Energy Technology Data Exchange (ETDEWEB)

Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then trow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs grain size shows a plateau for grains below critical size : these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected from the Yangsan fault system. ESR dates from the this fault system range from 870 to 240 ka. Results of this research suggest that long-term cyclic fault activity continued into the pleistocene.

2002-03-15

354

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

355

Determining concentration distribution of admixture from count ratemeter response in continuous analyses  

International Nuclear Information System (INIS)

A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).

1983-01-01

356

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

British Library Electronic Table of Contents (United Kingdom)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200?mm and 300?mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of ...

2008-01-01

357

Dependence of ion-induced Pd-silicide formation on nuclear energy deposition density  

Energy Technology Data Exchange (ETDEWEB)

Pd/sub 2/Si formation at the Pd-Si interface induced by irradiation with ions having a wide range of nuclear energy of deposition density has been investigated. It is found that the thickness of the silicide layer formed by irradiation is proportional to the ion fluence for irradiation with ions having low energy-deposition densities, while it is proportional to the square root of the fluence for irradiation with ions having energy-deposition densities. The results indicate that Pd/sub 2/Si formation is reaction limited when the energy-deposition density at the interface is low and is diffusion limited when it is high. The results are compared with the phenomenological theory developed by Horino et al. and it is shown that such a dependence of the limiting processes on the energy depositon density is induced when the diffusion is thermally activated while the reaction at the interface is radiation-enhanced.

1986-05-01

358

Dark Matter and Electroweak Symmetry Breaking from $SO(10)$  

CERN Document Server

We consider a minimal model of GUT scalar dark matter (DM) stabilized by the discrete gauge matter parity $P_{X}$ that arises from breaking of $SO(10)$. The dark sector comprises the complex singlet $S$ and the inert doublet $H_{2}$. GUT scale parameters are evaluated to the electroweak scale via Renormalization Group Equations (RGEs). Experimental and theoretical constraints limit the DM mass to the 80 GeV to 2 TeV range. The EW symmetry breaking is radiative and can occur via RGE running and 1-loop matching corrections from integrating out DM. Because the next-to-lightest scalar is almost degenerate with DM, it gives a background free displaced decay vertex at the LHC.

2010-01-01

359

Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap  

Energy Technology Data Exchange (ETDEWEB)

Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)

1994-07-01

360

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

361

Are There Enough Ionizing Photons to Reionize the Universe by z=6?  

CERN Document Server

An estimate for the number of ionizing photons per baryon as a function of redshift is computed based on the plausible extrapolation of the observed galaxy UV luminosity function and the latest results on the properties of the escape fraction of ionizing radiation. It is found that, if the escape fraction for low mass galaxies (Mtot<10^{11}Msun) is assumed to be negligibly small, as indicated by numerical simulations, then there are not enough ionizing photons to reionize the universe by z=6 for the cosmology favored by the WMAP 3rd year results, while the WMAP 1st year cosmology is marginally consistent with the reionization requirement. The escape fraction as a function of galaxy mass would have to be constant to within a factor of two for the whole mass range of galaxies for reionization to be possible within the WMAP 3rd year cosmology.

2007-01-01

362

Ar/sup +/ ion beam induced silicide formation mechanism at the Pf-Si interface  

Energy Technology Data Exchange (ETDEWEB)

Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.

1989-01-01

363

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

364

Advanced oxidation process based on ozone/electron beam irradiation for treating groundwater  

International Nuclear Information System (INIS)

There are several methods of generating OH free radicals from ozone and/or hydrogen peroxide and ultraviolet light. They all have in common that the OH free radicals originate in one single source only whereas in the combination of ozone with ionizing radiation two simultaneous working sources for the OH free radicals exist. The resulting higher OH free radical concentration makes this process especially apt for the remediation of low level contaminated groundwater as for example trichloroethylene (TCE) contamination in the sub-ppm range. A cost comparison between O_3/UV and O_3/electron beam for remediation of a groundwater contaminated with 100 ppb TCE indicated that for a throughput of about 5 million gallons/day the O_3/electron beam process is more cost-effective. (authors).

365

A routine chemical dosimetric system using the modified ceric sulphate dosimeter  

International Nuclear Information System (INIS)

The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.

1994-10-01

366

Strong-field quantum-electrodynamic processes in aligned crystals  

Energy Technology Data Exchange (ETDEWEB)

When a highly collimated beam of particles is aimed along the atomic rows of an aligned single crystal, the averaging effect of high speed motion results, to the lowest order of approximation, in crystal electric fields which are transverse to the atomic rows. The enormous magnitude of the crystal transverse electric fields is unsurpassed by any other known earth-bound macroscopic sources. For example, the field strengths along the <100> axis of tungsten at 77 K approach 9{center dot}10{sup 13}V/m. Thus quantum electrodynamic (QED) processes in strong fields which are thought to occur only in the extra-terrestrial environment can now be investigated in the laboratory. Here we review the results of measurements performed at the SPS facility in CERN using highly collimated beams of electrons, positrons and photons in the 20-200 GeV range, and germanium crystals cooled to 77 K with thicknesses ranging from 0.07 mm to 1.40 mm. The focus is on ...

1989-01-01

367

Spectral energy effects in ESR bone dosimetry: photons and electrons  

International Nuclear Information System (INIS)

The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference ...

368

Research and development program on solar thermal use in the high temperature range. Forschungs- und Entwicklungsprogramm zur solarthermischen Nutzung im Hochtemperaturbereich  

Energy Technology Data Exchange (ETDEWEB)

In the context of the research project, the physical basis of the direct decoupling of highly concentrated solar radiation in materials without the detour via absorbing heat exchanger walls was examined. Also, the first chemical processes suitable for the effective long-term storage of solar energy were analysed, relevant experiments were carried out and the necessary receiver techniques for high temperature applications were provided. The principle of direct coupling was examined on fluidized beds on the one hand and on cavity receivers, on the other hand. The contribution shows the results achieved in detail. It is recorded that first processes for storing solar energy in chemical reactions were able to be examined. Alkaline earth hydroxides accommodated in ceramic honeycomb structures seem to be possible as stores for medium temperature ranges around 500deg C. Investigations on receiver structure materials are also making progress. Highly ...

1988-03-01

369

Radon-mitigation in buildings  

International Nuclear Information System (INIS)

From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. Applicable mitigation ...

370

High frequency limit of vacuum microelectronic grating free-electron laser  

International Nuclear Information System (INIS)

The dependencies that limit high frequency operation of a vacuum microelectronic grating free-electron laser are examined. The important parameters are identified as the electron beam energy, emittance, and generalized perveance. The scaling of power with emittance and frequency is studied in the far-infrared spectral range using a modified scanning electron microscope (SEM) and submillimeter diffraction gratings. The SEM is suited to the task of generating and positioning a low emittance (10"-"2#pi#-mm-mrad), low current (100 #mu#A), but high current density (50-500 A cm"-"2) electron beam. It has been used to demonstrate the spontaneous emission process known as the Smith-Purcell effect. A vacuum microelectronic grating free-electron laser has the potential of generating radiation throughout the entire far-infrared spectral range which extends from approximately 10 to 10"3#mu#m. An introduction to the theory, initial ...

1995-08-21

371

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer ...

2003-06-01

372

Evaluating Parameterizations in General Circulation Models: Climate Simulation Meets Weather Prediction  

Energy Technology Data Exchange (ETDEWEB)

To significantly improve the simulation of climate by general circulation models (GCMs), systematic errors in representations of relevant processes must first be identified, and then reduced. This endeavor demands that the GCM parameterizations of unresolved processes, in particular, should be tested over a wide range of time scales, not just in climate simulations. Thus, a numerical weather prediction (NWP) methodology for evaluating model parameterizations and gaining insights into their behavior may prove useful, provided that suitable adaptations are made for implementation in climate GCMs. This method entails the generation of short-range weather forecasts by a realistically initialized climate GCM, and the application of six-hourly NWP analyses and observations of parameterized variables to evaluate these forecasts. The behavior of the parameterizations in such a weather-forecasting framework can provide insights on how these schemes ...

2004-05-06

373

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

374

A clinical perspective on common forms of acquired heterotopic ossification  

Energy Technology Data Exchange (ETDEWEB)

The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury ...

1991-02-01

375

A clinical perspective on common forms of acquired heterotopic ossification  

International Nuclear Information System (INIS)

The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury ...

376

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...

2003-09-15

377

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

378

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

380

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

381

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

382

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

383

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

384

The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core  

Energy Technology Data Exchange (ETDEWEB)

This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall temperature distribution in pebble bed core shows ...

2006-07-15

385

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its accuracy of ...

2001-03-01

386

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using ...

2003-08-17

387

Production of high-q ions by laser bombardment method  

International Nuclear Information System (INIS)

The expanding plasma produced when an intense pulse of laser radiation is focused in vacuum onto a solid target has been used as a source of highly stripped ions for collision cross-section measurements. Usable fluxes of carbon nuclei at energies of a few hundred eV/charge have been obtained by irradiation of graphite with pulses of CO"2 laser radiation at a focused power density of 3 x 10_1_0 W/cm_2. Bombardment of aluminum and iron targets at comparable power levels have yielded ions of maximum charges of 9 and 16 respectively. A time-of-flight apparatus has been constructed to utilize the laser source for measurement of electron capture cross sections for highly stripped ions in gases at energies in the few hundred eV/charge range. Apertures collimate an ion beam from the plasma blowoff, and an electrostatic analyzer selects ions from the expanding plasma which have the same energy per charge. The beam is directed ...

1981-01-01

388

Evaluation of a process for the decontamination of radioactive hotspots due to activated stellite particles  

International Nuclear Information System (INIS)

Some of the Indian pressurized heavy water reactors (PHWRs) which use Stellite balls in the ball and screw mechanism of the adjustor rod drive mechanism in the moderator circuit have encountered high radiation fields in the moderator system due to "6"0Co. Release of particulate Stellite is responsible for the hotspots in addition to the general uniform contamination of internal surfaces with "6"0Co. Extensive laboratory studies have shown that it is possible to dissolve these Stellite particles by adopting a three-step redox process with permanganic acid as the oxidizing agent. These investigations with inactive Stellite in powder form helped to optimize the process conditions. Permanganic acid was found to have the highest dissolution efficiency as compared to alkaline and nitric acid permanganate. The susceptibility of Stellite to corrode or dissolve was found to depend on the concentration of the permanganate, pH and temperature of the process and microstructure ...

2011-06-01

389

Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any significant differences among ...

2007-11-15

390

Carbon dioxide absorption of He--Ne laser radiation at 4. 2. mu. m: characteristics of self and nitrogen broadened cases  

Energy Technology Data Exchange (ETDEWEB)

A laser resonance absorption spectrometer is used to investigate the characteristics of both self and nitrogen collision broadened carbon dioxide in resonance with He--Ne laser radiation at 4.2 ..mu..m. The absorption coefficient in these broadening conditions has contributions from the R(28) to R(34) absorption lines of the ..nu../sub 3/ CO/sub 2/ spectrum. The Fletcher-Powell optimization method is used to reduce the raw absorption data and to find the best value average collision broadening coefficient and laser emission frequency for a Lorentzian line shape model of the contributing lines. Pure carbon dioxide absorption in a pressure range of from 0.0016 atm (1.25 Torr) to 0.33 atm (250 Torr) is described well by the model with an average self broadening coefficient of 0.084 +- 0.008 cm/sup -1/ atm/sup -1/ for laser frequencies located at either 2370.591 +- 0.020 cm/sup -1/ or 2371.135 +- 0.019 cm/sup -1/. Nitrogen broadened carbon dioxide ...

1989-03-01

391

Thermal performance of automotive aluminium plate radiator  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat transfer whilst ...

2005-06-01

392

Smith-Purcell free-electron laser  

International Nuclear Information System (INIS)

The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using permanent magnet undulators to couple the electron beam with the ...

1995-08-21

393

Radiation resistance of flexible graphites  

International Nuclear Information System (INIS)

Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure natural graphite were found to be radiation-resistant and suitable for use as seals ...

394

Irradiation with and without razoxane in the treatment of incompletely resected or inoperable recurrent rectal cancer. Results of a small randomized multicenter study  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, ...

2007-07-15

395

Induction and use of sex linked lethal mutations in the pink bollworm  

International Nuclear Information System (INIS)

The sterile insect release technique can often be improved by removal of females before release. Rearing efficiencies can also be increased if removal of the females occurs at early developmental stages. In order to begin to develop genetic sexing strains for the pink bollworm, Pectinophora gossypiella (Saunders), it was necessary to determine the best dosage of radiation for induction of viable sex linked recessive lethal mutations and to see if stocks containing induced sex linked lethals could be maintained in culture. Sex linked recessive lethal mutations can be detected by distorted sex ratios in the progeny of treated adults. However, in the pink bollworm, highly distorted sex ratios are common even in the absence of induced mutations. Therefore, a visible sex linked trait, purple eye, was used as a marker for the untreated X-chromosomes in crosses. Thus, the presence of a recessive sex linked lethal mutation induced by the radiation ...

1987-11-16

396

Analysis of Result of Treatment of Ewing's Sarcoma  

International Nuclear Information System (INIS)

Total 125 patients with primary and metastatic Ewing's sarcoma were treated in various ways between 1963 to 1977. Patients were divided into 3 groups according to the treatment methods. Group 1 was nonprotocol patients with or without chemotherapy. Total 58 patients were entered. Group 1 was divided into 2 subgroups. 33 patients were treated locally without chemotherapy and 25 patients were treated with local therapy and nonprotocol chemotherapy. Group 2 was treated with local therapy and plus T-2 regimen multiagent chemotherapy. 29 patients were entered. Group 3 was treated with local therapy and T-6 regimen multiagent chemotherapy. 38 patients were entered. Local treatments for primary tumor were surgery and/or radiation therapy. Radiation dose ranged between 2,000 and 8,000 rad. Patients with pulmonary metastases received bilateral pulmonary RT. Local recurrence rate was analyzed according to treatment groups and was ...

1984-06-01

397

Virtual reality in acquired brain injury upper limb rehabilitation: Evidence-based evaluation of clinical research  

British Library Electronic Table of Contents (United Kingdom)

Primary objective: Acquired brain injury (ABI) is associated with significant cognitive, behavioural, psychological and physical impairment. Hence, it has been important to leverage assessment approaches in rehabilitation by using current and emerging technologies, including virtual reality (VR). A number of VR rehabilitation programmes have been designed in recent years, mainly to improve upper limb function. However, before this technology gains widespread use, evaluation of the scientific evidence supporting VR-assisted rehabilitation is needed. The present review aimed to assess the rationale, design and methodology of research investigating the clinical impact of VR on ABI upper-limb rehabilitation. Research design: A total of 22 studies were surveyed using a Cochrane-style review. Re...

2009-01-01

398

Physical findings in the upper airways related to obstructive sleep apnea in men and women  

British Library Electronic Table of Contents (United Kingdom)

Conclusions. There are gender differences when it comes to the risk factors for sleep apnea. Large tonsils, a high tongue and a wide uvula are risk factors for sleep apnea in men, while large tonsils and a retrognathic mandible are risk factors in women. Upper airway abnormalities including mandibular retrognathia are, however, unable to predict sleep apnea among snorers being investigated for suspected sleep apnea. Objectives. To identify gender-specific risk factors for obstructive sleep apnea and the diagnostic performance from physical upper airway examinations among snoring men and women investigated because of suspected sleep apnea. Patients and methods. The dimensions of the uvula, tonsils, velopharynx and tongue, and nasal septal deviation, mandibular position, neck circumference, ...

2007-01-01

399

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the cooling water. Since the liquid membrane is formed on the entire surface of the container with no drying of the outer surface, the area of cooling ...

1993-05-07

402

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

410

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

413

Environmental survey of former royal artillery range hebrides  

International Nuclear Information System (INIS)

Full text of publication follows: The former UK Royal Artillery Range, Hebrides had been used to store and use radioactive miss distance indicators (R.A.M.D.I.) in the testing of Rapier missiles. As part of the testing, missiles were fired out to sea between about 1970 and 1981. Concerns were expressed in early 2004 by some within the local community that there was an unknown, ongoing hazard to them from the impact on the local environment resulting from the use radioactive material in these trials. Accordingly Defence Science and Technology Laboratory, Environmental Science Department (D.s.t.l. E.S.D.) were tasked by the Ministry of Defence to carry out an Environmental Survey of the former Royal Artillery Range, Hebrides and surrounding areas; the environmental survey was carried between the dates of 18 28 May 2004. D.s.t.l. E.S.D. environmental survey focussed upon buildings and areas within and immediately adjacent to the ...

2006-05-15

415

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...

416

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

418

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

420

Upper reactor core supporting structure of highly earthquake-proof type  

International Nuclear Information System (INIS)

Fuel assemblies in a reactor pressure vessel are disposed in a reactor core shroud. The own weight of the fuel assembly is supported by a reactor core support plate, and is supported, for the horizontal direction, by an upper lattice plate and the reactor core support plate. A support portion for the upper portion of the fuel assembly is disposed above the fuel assembly, and a support portion for the support portion described above is joined to a shroud head by welding. The support portion for the upper portion of the fuel assembly has a network-like portion which absorbs and disperses rising force which exerted on the fuel assembly when the fuel assembly is risen by seismic forces. The rising force exerted on the fuel assembly absorbed by the network-like portion is effectively transferred to the shroud head by the support portion. With such a constitution, rising of the fuel assembly can be prevented against the seismic ...

1993-05-14

421

Unbiased cut selection for optimal upper limits in neutrino detectors the model rejection potential technique  

CERN Document Server

We present a method for optimising experimental cuts in order to place the strongest constraints (upper limits) on theoretical signal models. The method relies only on signal and background expectations derived from Monte-Carlo simulations, so no bias is introduced by looking at actual data, for instance by setting a limit based on expected signal above the ``last remaining data event.'' After discussing the concept of the ``average upper limit,'' based on the expectation from an ensemble of repeated experiments with no true signal, we show how the best model rejection potential is achieved by optimising the cuts to minimise the ratio of this ``average upper limit'' to the expected signal from the model. As an example, we use this technique to determine the limit sensitivity of kilometre scale neutrino detectors to extra-terrestrial neutrino fluxes from a variety of models, e.g. active galaxies and gamma-ray bursts. We ...

2003-01-01

422

The strength of the Inner Model Hypothesis  

CERN Document Server

The Inner Model Hypothesis (IMH) and the Strong Inner Model Hypothesis (SIMH) were introduced by the first author in ``Internal consistency and the inner model hypothesis'', Bulletin of Symbolic Logic, December 2006. In this article we establish some upper and lower bounds for their consistency strength.

2007-01-01

423

The effect of lecithin on intestinal cholesterol uptake by rat intestine in vitro  

UK PubMed Central (United Kingdom)

1. Sacs 20 cm long were obtained from the upper half of the small intestine of bile fistula rats (bile duct cannulated 48 hours previously). The sacs were everted, filled with oxygenated phosphate...Full Text Available

1973-03-01

424

Studies on micellar fatty acid uptake by rat intestine in vitro with reference to the role of bile  

UK PubMed Central (United Kingdom)

1. The uptake and esterification to trigylceride of oleic acid in micellar form was studied in rat intestine in vitro. Sacs of the upper half of the everted intestine taken from bile...Full Text Available

1973-03-01

425

Reflood experiments with simultaneous upper and lower plenum injection in the REWET-II rod bundle facility  

International Nuclear Information System (INIS)

A series of 27 reflood experiments has been carried out in a full-length electrically heated rod bundle facility. The primary objective of these tests was to study the effects of a simultaneous upper plenum and downcomer coolant injection and to provide data for the verification of computer codes. The experimental results indicate that an upper plenum injection alone cools the test rods slowly, a simultaneous coolant injection to the downcomer improves cooling significantly, and a downcomer injection alone cools the test rod bundle best if the total value of the coolant flow rate is the same in these three different cases. If the coolant injected to the upper plenum increases the total flow rate, the quench time of the test rods decreases at all elevations. Quenching time and clad temperature histories calculated with the computer codes NORCOOL-I and FLOOD4 are in a reasonable quantitative agreement with experiments in the ...

1983-02-01

426

Predictive Value of Kushida Index and Acoustic Pharyngometry for the Evaluation of Upper Airway in Subjects With or Without Obstructive Sleep Apnea  

UK PubMed Central (United Kingdom)

Acoustic pharyngometry is a relatively new noninvasive method that quantifies geometrically complexed pharyngeal dimensions. Our study aimed to investigate the predictability and usefulness of acoustic...Full Text Available

2004-10-01

427

Phytochrome-mediated Electric Potential Changes in Oat Seedlings 1  

UK PubMed Central (United Kingdom)

Brief exposures to red light induce far red-reversible changes of 5 to 10 millivolts magnitude in the upper 1 centimeter of etiolated Avena coleoptiles. The changes begin within 15...Full Text Available

1972-12-01

428

Natural Variation of Drug Susceptibility in Wild-Type Human Immunodeficiency Virus Type 1  

UK PubMed Central (United Kingdom)

Wild-type viruses from the ViroLogic phenotype-genotype database were evaluated to determine the upper confidence limit of the drug susceptibility distributions, or “biological cutoffs,”...Full Text Available

2004-02-01

429

MARINE INFLUENCE IN THE UPPER ORDOVICIAN JUNIATA FORMATION (POTTERS MILLS, PENNSYLVANIA): IMPLICATIONS FOR THE HISTORY ...  

Science.gov (United States)

... on a transgressive surface; examples from the Silurian Whirlpool Sandstone of southern Ontario, Canada. Journal of Sedimentary ... and C. J. Salas. 1991. The Lower Silurian Whirlpool Sandstone. in Cheel, ...

430

Lesson 5: How Can You  

Wastenet

Pumped storage plants 20 are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.That is,

431

Lesson 5: How Can You  

Wastenet

Pumped storage plants are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.

432

Hypothesis for induction and propagation of chemical sensitivity based on biopsy studies.  

UK PubMed Central (United Kingdom)

The reactive airways dysfunction syndrome (RADS), the reactive upper airways dysfunction syndrome (RUDS), the sick building syndrome (SBS), and the multiple chemical sensitivity syndrome (MCS) are overlapping...Full Text Available

1997-03-01

433

Gastric carcinoids: Between underestimation and overtreatment  

UK PubMed Central (United Kingdom)

Gastric carcinoids (GCs), which originate from gastric enterochromaffin-like (ECL) mucosal cells and account for 2.4% of all carcinoids, are found increasingly in the course of upper gastrointestinal...Full Text Available

2009-05-14

434

Clinical Features and Treatments of Upper Lumbar Disc Herniations  

UK PubMed Central (United Kingdom)

ObjectiveDisc herniations at the L1-L2 and L2-L3 levels are different from those at lower levels of the lumbar spine with regard to clinical characteristics and surgical outcome....Full Text Available

2010-08-01

435

CHANDFS2MS - Chandra Deep Field South 2 ... - HEASARC - NASA  

Science.gov (United States)

This table contains point-source catalogs for the ~2 Ms exposure of the Chandra Deep ... Source positions are determined using centroid and matched-filter techniques; .... The 1-sigma upper statistical error (Gehrels 1986, ApJ, 303, ...

436

Bragg curves of fission fragments in gases  

Energy Technology Data Exchange (ETDEWEB)

An unexpectedly high probability of collisions between the fission particles and the atoms in an ionization chamber along the entire particle track causes a strong fluctuation of the shapes of the Bragg curves. This fluctuation imposes an upper limit of the charge resolution ..delta..Z/Z which can be achieved.

1986-03-01

437

Augmenting Clinical Evaluation of Hemiparetic Arm Movement With a Laboratory-Based Quantitative Measurement of Kinematics as a Function of Limb Loading  

UK PubMed Central (United Kingdom)

BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available

2008-01-01

438

A New Suchian Archosaur From The Upper Triassic Of North Carolina  

Science.gov (United States)

... rugose ridge along dorsolateral edge of skull; s, scapula; sc, supinator crest; sls, surface for articulation with ... robust supraglenoid buttress of the scapulocoracoid; immediately narrowing scapula po...

439

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

440

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

441

Vulnerability of soil resources to heavy metals contamination in Central Bekaa-Lebanon  

International Nuclear Information System (INIS)

Full text.Changes in land use and urbanization yield more pressure put on limited soil and water resources, including the risk of pollution with toxic heavy metals. The study area lies in the Bekaa valley totaling about 12753 ha. The valley receives from the west torrential fan deposits and a mixture of colluvial and alluvial material. The principal soil classes are Fluvisols, Cambisols, Regosols, Vertisols and Luvisols. The area is populated and also the most important agricultural part of the plain. Agriculture in the plain is being practiced mainly with cash, field crops and vegetables. The western surrounding area is being used mainly for terraced fruit trees. This Arab-German Technical Cooperation Project (ACSAD-BGR) aimed, following the ISO standards and Eikman-Klocke recommendations, at investigating the nature of the extends of soil pollution by heavy metals in two pilot areas: The central Bekaa-Lebanon and Ghouta-Damascus. Different institutions cooperate in the implementation ...

2000-11-23

442

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The ...

2003-05-01

443

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

Energy Technology Data Exchange (ETDEWEB)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a {sup 137}Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data. The average biodiffusion coefficient, at 1.8 {+-} 0.9 cm{sup 2} y{sup -1}, is in good agreement with the values quoted by other workers on the bioturbation effects of this polychaete species. ...

2010-11-15

444

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

International Nuclear Information System (INIS)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a "1"3"7Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data. The average biodiffusion coefficient, at 1.8 #+-# 0.9 cm"2 y"-"1, is in good agreement with the values quoted by other workers on the bioturbation effects of this polychaete species. The ...

2010-11-01

445

Analysis of the role of the planetary boundary layer schemes during a severe convective storm  

Energy Technology Data Exchange (ETDEWEB)

The role played by planetary boundary layer (PBL) in the development and evolution of a severe convective storm is studied by means of meso-scale modeling and surface and upper air observations. The severe convective precipitation event that occurred on 14 September 1999 in the northeast of the Iberian Peninsula was simulated by means of the mesoscale model MM5 (version 3) using three different PBL schemes. The numerical results show a large impact of the PBL schemes on the precipitation fields associated to the convective storm. The schemes are based on different physical assumptions: the nonlocal first order medium-range forecast (MRF) and blackadar (BLA) scheme and the local, one-and-a-half order ETA scheme. Surface and radar observations are used to validate the model results. The comparison focuses on three aspects: the evolution, the spatial distribution and the 24-h accumulated precipitation. The comparison with rain gauge observations ...

2004-07-01

446

Short rotation coppice harvesting: an evaluation of the Salix Maskiner Bender III  

Energy Technology Data Exchange (ETDEWEB)

Version III of the Salix Maskiner ``Bender`` coppice harvester was used to successfully harvest 11.2 hectares of short rotation poplar and willow coppice in February 1997. On a wide range of typical UK crop and site conditions, the Swedish harvester was shown to have productivity rates ranging from 4.28 to 7.97 odt/smh. Based on a total system cost of Pound 81.26 per scheduled machine hour, the Bender III is able to produce wood chip for between Pound 10.20 and pound 18.97 per dry tonne. The variation in machine productivity is dependent on crop productivity and working method, emphasising the importance of site design in optimising system efficiency. In willow crops the wood chip produced by the Bender III contained a significant amount of material greater than 75mm in length. The bulk of the chips however, fell into the 5-45mm category with only a very limited amount of fine materials less than 5mm in length. The chips from poplar crops were ...

1997-12-31

447

Radiofrequency electromagnetic fields in the Cookridge area of Leeds  

Energy Technology Data Exchange (ETDEWEB)

On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency ...

2002-07-01

448

Neutron induced reaction cross-sections of iron in the energy range 1 to 20 MeV: A work programme  

International Nuclear Information System (INIS)

Iron is one of the main constituents of stainless steel which is used as a structural material in nuclear reactors. In fast and conceptual fusion and fusion-fission hybrid systems the primary energy range of neutron interaction lies between 1 and 20 MeV which opens up several reaction channels. The reaction cross-sections in this energy range are important for dosimetry, radiation damage, neutronics and safety studies of nuclear reactors. Keeping this in view Nuclear Data Section of the International Atomic Energy Agency has sponsored a Research Co-ordination Programme on Methods for the Calculation of Fast Neutron Nuclear Data for Structural Elements. Under this programme we propose to study (n,n'), (n,2n), (n,3n), (n,p), (n,np), (n,pn), (n,#alpha#), (n,n#alpha#), (n,#alpha#n) and (n,#gamma#) reaction cross-sections. Besides these, total, elastic and discrete level inelastic scattering cross-sections, angular distributions ...

1988-01-01

449

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that a treatment planning ...

2001-02-01

450

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of {sup 40}K, {sup 238}U and {sup 232}Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of {sup 40}K, {sup 238}U and {sup 232}Th in local prepared diets ranged between 60 and 494 Bq kg{sup -1}, between BDL and 48 Bq kg{sup -1} and between BDL and 17 Bq kg{sup -1}, respectively. The internal effective dose to individuals from the consumption of the food types was ...

2007-04-15

451

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

International Nuclear Information System (INIS)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of "4"0K, "2"3"8U and "2"3"2Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of "4"0K, "2"3"8U and "2"3"2Th in local prepared diets ranged between 60 and 494 Bq kg"-"1, between BDL and 48 Bq kg"-"1 and between BDL and 17 Bq kg"-"1, respectively. The internal effective dose to individuals from the consumption of the food types was estimated on the basis of the ...

2007-04-01

452

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the ...

2005-10-15

453

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO_4  

International Nuclear Information System (INIS)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the artificially ...

2005-10-01

454

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The ...

2007-07-01

455

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also ...

1994-02-01

456

A radiation hardening model of 9Cr-martensitic steels including Dpa and helium  

International Nuclear Information System (INIS)

Full text of publication follows: Low activation ferritic/martensitic steels are receiving a high priority in the European long term materials research. Although extensively investigated, the available experimental data do not cover all required parameter ranges and cannot unambiguously be used to produce hardening/embrittlement trend curves. Therefore, the main objective of this work is to provide a physically-based engineering model offering a rational to experimental observations. From the literature, experimental data were selected to establish a database that mainly consists of 8 to 9Cr-steels irradiated in the range of 50 to 600 deg. C up to 30 dpa and with a He-content up to 5000 appm. The database includes neutron and proton irradiations, He-implanted as well as B- and Ni-doped steels. Because of the difficulty of interpretation inherent to the Charpy impact test, only tensile data were considered. The difficulty stems from the large ...

2007-12-10

457

Stratigraphy and sedimentary environment of the Coalspur Formation  

Energy Technology Data Exchange (ETDEWEB)

The Coalspur Formation is a continental succession of interbedded mudstone, siltstone and fine grained sandstone with subordinate coarser grained sandstone layers and channel lag deposits. Chert-pebble conglomerate (the Entrance conglomerate) occurs at the base of the formation, and coal beds interbedded with coaly shale and numerous thin bentonites occur in the upper part of the formation. An economically significant amount of high-quality thermal coal occurs within the upper, Paleocene part of the formation named the Coalspur coal zone. Coal from this zone, also known as the Coal Valley coal zone is being exploited in the Coal Valley Mine. 17 refs., 4 figs.

1990-01-01

458

Short term relative sea-level oscillations in Upper Devonian Nisku Formation (Alberta, Canada): application to hydrocarbon exploration and recent discoveries  

Energy Technology Data Exchange (ETDEWEB)

The relationship between short term relative sea-level oscillations and the reef, off-reef deposits geometry of an Upper Devonian third order sequence highstand of the Nisku Formation in west central Alberta was studied through the analysis of high resolution sequence stratigraphy. Hydrocarbon generation was reconstructed by total organic carbon values and migration patterns that were dependent on the geometry of three fourth order sequences. This stratigraphic reconstruction provided the key to recent hydrocarbon discoveries such as in the Brazeau southern reef margin.

1997-09-01

459

Principal geological results of petroleum and gas prospecting on Southern Sakhalin  

Energy Technology Data Exchange (ETDEWEB)

Results are given for deep-level petroleum and gas drilling probes in various coastal zones of Southern Sakhalin covering the Poronai depression and the Aniv Bay trough. The exploratory probes indicate that the Middle Miocence deposits of the Boundary trough contain commercial-size deposits of petroleum, that commercial-size gas deposits are in the upper Myocene deposits of the Aliv Bay trough, and that the upper Cretaceous and Cenozoic deposits of the eastern section of Southern Sakhalin lack folded deformations. 7 references, 2 figures.

1981-01-01

460

Insulated letter drop plate  

Energy Technology Data Exchange (ETDEWEB)

An insulated letter drop plate comprises a back plate having an opening for the mail having two hinges at its upper part to attach a cover to; a frame for retaining a first insulation around its perimeter and around the opening; and suitable insulation. This back plate is also provided with an upper curved extension to cover and conceal said hinges. A cover is provided with two complementary hinges to be articulated with the first hinges on the back plate, and with a frame around the perimeter for the retention of a second insulation. A wire joins the first and second hinges, and a coil spring on the wire keeps the cover normally closed.

1988-09-06

461

Increase in the upper critical magnetic field in structurally inhomogeneous superconductors  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the temperature dependence of the upper critical magnetic field, Hc2(T), of structurally inhomogeneous superconductors (e.g., ternary molybdenum chalcogenides, A-15 compounds, transition metal alloys, and amorphous films) are investigated analytically. The MWGH equation for Hc2(T) is generalized to the case of weakly inhomogeneous systems with a characteristic inhomogeneity scale much smaller than the effective coherence length. It is shown that an increase in the dispersion of the diffusion coefficient leads to an increase in the slope and width of the linear section of the Hc2(T) curve. 11 references.

1987-11-01

462

A wrench for screwing and unscrewing lock connections  

Energy Technology Data Exchange (ETDEWEB)

A wrench is proposed for screwing and unscrewing lock connections, which includes a spring loaded base, a faceplate with low moment and high moment mechanisms and subassemblies for moving them. In order to increase the operational reliability, the wrench is equipped with uprights evenly disposed along the perimeter of the base with hinged suspensions for linking the base, the hinged suspension is made in the form of interconnected links for the upper and lower traverses with the hinges. One of the hinges is positioned between the upper traverse and the upright, while the other is located between the lower traverse and the base.

1983-01-01

463

Survey of Radiation Protection Education and Training in Finland in 2003  

Energy Technology Data Exchange (ETDEWEB)

The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...

2004-07-01

464

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. ...

465

The mobility of anthropogenic {sup 129}I in a shallow sand aquifer at Sturgeon Falls, Ontario, Canada  

Energy Technology Data Exchange (ETDEWEB)

The transport and partitioning of {sup 129}I has been examined for a shallow groundwater flow system at Sturgeon Falls in northeastern Ontario. Recharge into a sandy surficial postglacial deltaic aquifer occurs in the vicinity of a seasonally-wet boreal forest. Concentrations of stable iodine, {sup 129}I, tritium, radiocarbon, stable isotopes and major ions were measured on samples of groundwater and precipitation. The present-day tritium profile delineates the position of the early 1960's above-ground nuclear weapons pulse at a depth of approximately 12 m. The concentrations of stable iodine for groundwaters above, near and below the above-ground nuclear weapons pulse range from 0.07 to 1.7 ppb. Over that same interval {sup 129}I concentrations decreased from 1.9 x 10{sup 6} atoms/L at 9 m, to approximately 1.9 x 10{sup 5} atoms/L in tritium-depleted waters at 35 m, below the present-day depth of the recharging above-ground nuclear weapons peak at ...

2005-07-01

466

Shedding Synchrotron Light on a Puzzle of Glasses  

ScienceCinema

...introduced english ...the range of simple english ...the range of simple english ...

467

The benefits of low level radiation  

Energy Technology Data Exchange (ETDEWEB)

The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).

1997-06-01

468

Stimulated radiation of high - current relativistic electron beams  

International Nuclear Information System (INIS)

The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.

1987-01-01

469

Synthesis, characterization and optical properties of a high NIR reflecting yellow inorganic pigment: Mo"6"+ doped Y_2Ce_2O_7 as a cool colorant  

International Nuclear Information System (INIS)

Full text: Pigments possessing the ability to confer high solar reflectance have received considerable attention in recent years. The inorganic class of NIR reflective pigments are mainly metal oxides and are primarily employed in two applications: (i) visual camouflage and (ii) reducing heat build up. More than half of the solar radiation consists of near-infrared radiation (52%), the remaining being 43% visible light and 5% ultraviolet radiation. Over heating due to solar radiation negatively affects comfort in the built environment and contributes substantially to electrical consumption for air conditioning and release of green house gases. A pigment which has strong reflections in the NIR region (780-2500 nm) can be referred to as a 'cool' pigment. However, most of the NIR reflective inorganic pigments particularly yellow (eg. cadmium yellow, lead chromate, chrome titanate yellow etc.) contain toxic ...

2010-11-24

470

XPS/AES Study of Electrical and Chemical Properties of Pd/SiC Interface  

Science.gov (United States)

Silicon carbide (SiC) based electronic devices are of great importance for applications under the condition of high temperature, high power and high radiation. Schottky diodes of Palladium/SiC are good candidates for hydrogen and hydrocarbon gas sensors at elevated temperature. The detection sensibility of the diodes has been found heavily temperature dependent. In this work, the electrical and chemical properties of Pd/SiC Schottky contacts were studied by XPS and AES at different annealing temperatures. Schottky diodes were made by depositing ultra-thin palladium films onto a silicon carbide substrate. No significant change in the Schottky barrier height of the Pd/SiC contact was found in the temperature range of 300-673K. Palladium diffusion into SiC and the formation of palladium silicides were observed at room temperature and became significant at 300^oC and higher temperature. The mechanism of diffusion and reaction at the Pd/SiC ...

1997-11-01

471

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low temperature cooling water have been drained off into the sea, it ...

472

Spectral dependence of absorption photoinduced in a Bi{sub 12}TiO{sub 20} crystal by 532-nm laser pulses  

Science.gov (United States)

The spectral dependences of absorption photoinduced in a pure bismuth titanium oxide crystal by 532-nm laser pulses are studied. It is shown that optical absorption in the crystal in the range from 492 to 840 nm increases with increasing exposure. The photoinduced absorption relaxes in the dark for more than 60 hours. A model of photoinduced absorption is proposed which assumes the population of two trap centres with the normal energy distribution law for the concentrations of electrons photoexcited from donors to the conduction band. This model well describes the spectral dependences of photoinduced absorption by using the average ionisation energies of the traps E{sub 1} = 1.60 eV and E{sub 2} = 2.57 eV. The model is used to estimate the increase in the photorefractive sensitivity of a bismuth titanium oxide crystal in the near IR region, which was earlier observed after exposing the crystal to visible radiation. It is predicted that the ...

2007-11-30

473

Solar syngas production from CO"2 and H"2O in a two-step thermochemical cycle via Zn/ZnO redox reactions: Thermodynamic cycle analysis  

British Library Electronic Table of Contents (United Kingdom)

Solar syngas production from CO"2 and H"2O is considered in a two-step thermochemical cycle via Zn/ZnO redox reactions, encompassing: 1) the ZnO thermolysis to Zn and O"2 using concentrated solar radiation as the source of process heat, and 2) Zn reacting with mixtures of H"2O and CO"2 yielding high-quality syngas (mainly H"2 and CO) and ZnO; the ZnO is recycled to the first, solar step, resulting in net reaction @bCO"2 + (1 - @b)H"2O -> @bCO + (1 - @b)H"2. Syngas is further processed to liquid hydrocarbon fuels via Fischer-Tropsch or other catalytic processes. Second-law thermodynamic analysis is applied to determine the cycle efficiencies attainable with and without heat recuperation for varying molar fractions of CO"2:H"2O and solar reactor temperatures in the range 1900-2300 K. Conside...

2011-01-01

474

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for ...

1988-01-01

475

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for ...

1988-08-01

476

Radiation damage and hardening of molybdenum in 29 MeV alpha particle straggling zone  

International Nuclear Information System (INIS)

Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.

477

Planar excilamp on rare gas chlorides pumped by a transverse self-sustained discharge  

Science.gov (United States)

The design and parameters of a UV-VUV spontaneous radiation source - an excilamp operating on chlorides of rare gases ArCl{sup *}, KrCl{sup *} and XeCl{sup *} in the wavelength range 175-308 nm are presented. The Ne-Xe(Kr, Ar)-HCl mixtures were excited by a high-pressure self-sustained discharge with spark preionisation. It is shown that upon pumping mixtures of rare gases and halogens by a transverse discharge, the intensities of the B-X emission band of molecules ArCl{sup *}, KrCl{sup *} and XeCl{sup *} are comparable and up to 90% of the emission energy of excilamps can be concentrated in the UV region. The peak UV power density at 222 and 308 nm on the output window of the excilamp was {approx}2 kW cm{sup -2} for the pulse energy up to {approx} 3 mJ. The output emission energy of the excilamp at 175 nm achieved {approx}0.6 mJ and the peak power density was {approx}0.4 kW cm{sup -2}. (laser applications and other topics in quantum ...

2006-02-28

478

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...

2007-04-01

479

Observations on the contributions of environmental restraints and innate stem cell ability to hematopoietic regeneration  

Energy Technology Data Exchange (ETDEWEB)

A competitive repopulation assay utilizing chromosome markers was used to assay the reconstituting potential of hematopoietic populations. The test populations consisted of tibial murine marrow locally irradiated with doses ranging from 1.5 Gy to 8.5 Gy and of marrow generated from either murine splenic or marrow stem cells. The purpose of this assay was to assess the innate proliferative potential and microenvironmental influences on the ability to repopulate. Regardless of origin, spleen repopulating ability consistently agreed with spleen colony-forming unit (CFU-s) content. Doses of radiation from 5 Gy to 8.5 Gy diminished, by a factor of 2, the ability to repopulate marrow despite maintenance of CFU-s levels. Marrow generated from splenic stem cells had one-fifth the repopulating ability of marrow derived from marrow stem cells, even though CFU-s levels were equivalent. The results imply that the splenic environment can only maintain stem ...

1988-03-01

480

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

Energy Technology Data Exchange (ETDEWEB)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a ...

2000-07-01

481

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

International Nuclear Information System (INIS)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a ...

1999-06-13

482

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

483

Home radon levels and seasonal correction factors for the Isle of Man  

Energy Technology Data Exchange (ETDEWEB)

Ionizing radiation dose levels due to home radon can rise to levels that would be illegal for workers in the nuclear industry. It is well known that radon levels within homes and from home to home, and also from month to month, vary considerably. To define an Isle of Man radon seasonal correction factor, readings were taken in eight homes over a 12 month period. An average island indoor exposure of 48 Bq m{sup -3} (range 4-518 Bq m{sup -3}) was determined from 285 homes selected from a cohort of 1300 families participating in the European Longitudinal Study of Pregnancy and Childhood (ELSPAC) in the Isle of Man. This compares with a UK home average of 20 Bq m{sup -3} and a European Union average (excluding UK) of 68 Bq m{sup -3}. Ten homes of those measured were found to have radon levels above the National Radiological Protection Board 200 Bq m{sup -3} action level. There are 29 377 homes on the Isle of Man, suggesting that there could be some ...

2000-08-01

484

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the observations.

2003-05-15

485

Experimental determination of the thermal diffusivity of molten alkali halides by the forced Rayleigh scattering method. I. Molten LiCl, NaCl, KCl, RbCl, and CsCl  

Energy Technology Data Exchange (ETDEWEB)

As a series of experimental determinations of the thermal diffusivity of molten alkali halides, this paper describes measurements on five molten alkali metal chlorides (LiCl, NaCl, KCl, RbCl, and CsCl) in the temperature range up to 1440 K by the forced Rayleigh scattering method. K[sub 2]Cr[sub 2]O[sub 7] is employed as a dye substance to color the transparent molten salts. In comparison with the present results converted into thermal conductivity, most of the previous experimental data obtained by steady-state methods show larger values, up to about five times, which may be due to the systematic error caused by the presence of convection and radiation. It is found that the thermal conductivity of these series of molten alkali metal chlorides decreases with increasing molecular weight, and their temperature coefficients are weakly negative. 24 refs., 9 figs., 6 tabs.

1992-07-01

486

ESR dating of fault rocks  

Energy Technology Data Exchange (ETDEWEB)

Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then grow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs. grain size shows a plateau for grains below critical size; these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected near the Gori nuclear reactor. Most of the ESR signals of fault rocks collected from the basement are saturated. This indicates that the last movement of the faults had occurred before the Quaternary period. However, ESR dates from the Oyong fault zone ...

2003-02-15

487

Development of HT-9 for liquid-metal reactor components  

International Nuclear Information System (INIS)

Alloy HT-9 is being used for both duct and cladding applications in advanced liquid-metal reactor (LMR) experiments. This tempered martensitic steel was selected for use as an LMR core component material primarily because of its excellent resistance to radiation-induced swelling. Experiments conducted in the Fast Flux Test Facility (FFTF) at 410 degree C and exposures in the range of 150 to 175 displacements per atom (dpa) have shown that Ht-9 exhibits only a 0.2 to 0.3% increase in volume. Cold-worked austenitic steels exhibit volumetric increases of 20 to 30% at 410 degree C, Alloy HT-9 is being used for a series of fuel pin experiments in the FFTF, and these tests have achieved a burnup of 175 MWd/kg metal and a fluence of 25 x 10"2"2 n/cm"2 (E > 0.1 MeV) without fuel pin breach. The high confidence placed in HT-9 is based on a wide series of in- and ex-reactor experiments. Test results for these experiments are summarized in this paper.

1989-11-26

488

Design and experimental results on a terawatt magnetically controlled plasma opening switch  

Energy Technology Data Exchange (ETDEWEB)

The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load voltage ranged from one to two megavolts. The experiments ...

1998-05-01

489

Demonstration of a wide-band compact free electron laser to the THZ imaging of bio samples  

International Nuclear Information System (INIS)

We have developed a compact terahertz (THz) free electron laser (FEL). The FEL operates in the wavelength range of 100-1200 #mu#m, which corresponds to 0.3-3 THz. THz radiation from the FEL shows much higher power of 100 W compared to the power level, <100 mW, of the table-top sources by conventional lasers. The THz FEL beam shows good performance in pulse-energy stability, polarization, spectrum and spatial distribution. The main application of the FEL is THz imaging for bio-medical researches. We demonstrated the THz imaging of bugs for living condition at 3 THz. The bugs were died just before experiments, so they were not dried. We could get transmitted information through the samples by using the THz FEL beam. In this paper, we will estimate and discuss the required power level of the THz source for the practical application of the imaging.

2007-05-21

490

Control of population dose equivalent from naturally occurring radionuclides in building materials  

International Nuclear Information System (INIS)

Naturally occurring radionuclides in building materials are a source of external and interal radiation exposure to essentially the entire US population. Although detailed data are not available, estimates are that the average contribution from such sources to the external dose equilvaent rate in brick and masonry houses is about 5 to 10 mrem/year. For critical population groups, values reported in the literature for the contribution from such sources range up to a hundred mrem/year or more. Dose equivalent rates to the lungs are even higher and, for abnormal situations, it would appear that control measures, either on a voluntary or mandatory (legislative) basis should be considered. Such measures include: (1) material substitution; (2) improved manufacturing standards; (3) changes in basic building designs; (4) application of surface sealants; and (5) increased ventilation accompanied by processes for the adsorption and/or filtration of ...

491

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic response of the graphite chamber is nearly ...

2000-03-01

492

Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?  

CERN Document Server

Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with the dependence of ...

2008-01-01

493

Atmospheric scintillations and laser safety  

Science.gov (United States)

Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much greater than that ...

2011-09-01

494

A new plateau in the dose-survival-time response of the golden hamster (Mesocricetus auratus) from whole body irradiation  

International Nuclear Information System (INIS)

The survival time of golden hamsters (Mesocricetus auratus) after whole-body "6"0Co-#gamma#-irradiation in the range of 600 to 200 000 rad was investigated. The two plateaus of the dose-survival curve which correspond to bone marrow and gastrointestinal death are similar to those of other species such as mice, rats and mongolian gerbils. A new plateau occurring 40-57 hours after doses of 30 000-60 000 rad, where there is a little reduction in survival time, has been found. It is in addition to the well recognized central nervous system (CNS) syndrome. This plateau is observed only in golden hamsters, presumably because of their relatively high resistance to CNS syndrome. Experiments involving partial body irradiation of the animals indicate that the target is in the cephalic one-third of abdomen. The new segment may well indicate a new type of acute somatic radiation injury different from the well known bone marrow, gastrointestinal and CNS ...

1981-01-01

495

A hierarchical framework for coupling surface fluxes to atompsheric general circulation models: The homogeneity test  

Energy Technology Data Exchange (ETDEWEB)

The atmosphere and the biosphere are inherently coupled to one another. Atmospheric surface state variables such as temperature, winds, water vapor, precipitation, and radiation control biophysical, biogeochemical, and ecological processes at the surface and subsurface. At the same time, surface fluxes of momentum, moisture, heat, and trace gases act as time-dependent boundary conditions providing feedback on atmospheric processes. To understand such phenomena, a coupled set of interactive models is required. Costs are still prohibitive for computing surface/subsurface fluxes directly for medium-resolution atmospheric general circulation models (AGCMs), but a technique has been developed for testing large-scale homogeneity and accessing surface parameterizations and models to reduce this computational cost and maintain accuracy. This modeling system potentially bridges the observed spatial and temporal ranges yet allows the incorporation of ...

1993-12-31

496

A Measurement of the Spatial Distribution of Diffuse TeV Gamma Ray Emission from the Galactic Plane with Milagro  

Energy Technology Data Exchange (ETDEWEB)

Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l {element_of} [65{sup o}, 85{sup o}]). For the Cygnus region, the ...

2008-05-14