WorldWideScience

Sample records for titration calorimetry study

  1. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    Science.gov (United States)

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  2. Thermodynamic investigations of protein's behaviour with ionic liquids in aqueous medium studied by isothermal titration calorimetry.

    Science.gov (United States)

    Bharmoria, Pankaj; Kumar, Arvind

    2016-05-01

    While a number of reports appear on ionic liquids-proteins interactions, their thermodynamic behaviour using suitable technique like isothermal titration calorimetry is not systematically presented. Isothermal titration calorimetry (ITC) is a key technique which can directly measure the thermodynamic contribution of IL binding to protein, particularly the enthalpy, heat capacities and binding stoichiometry. Ionic liquids (ILs), owing to their unique and tunable physicochemical properties have been the central area of scientific research besides graphene in the last decade, and growing unabated. Their encounter with proteins in the biological system is inevitable considering their environmental discharge though most of them are recyclable for a number of cycles. In this article we will cover the thermodynamics of proteins upon interaction with ILs as osmolyte and surfactant. The up to date literature survey of IL-protein interactions using isothermal titration calorimetry will be discussed and parallel comparison with the results obtained for such studies with other techniques will be highlighted to demonstrate the accuracy of ITC technique. Net stability of proteins can be obtained from the difference in the free energy (ΔG) of the native (folded) and denatured (unfolded) state using the Gibbs-Helmholtz equation (ΔG=ΔH-TΔS). Isothermal titration calorimetry can directly measure the heat changes upon IL-protein interactions. Calculation of other thermodynamic parameters such as entropy, binding constant and free energy depends upon the proper fitting of the binding isotherms using various fitting models. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Isothermal Titration Calorimetry in the Student Laboratory

    Science.gov (United States)

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  4. Use of isothermal titration calorimetry to study the interaction of short-chain alcohols with lipid membranes

    DEFF Research Database (Denmark)

    Trandum, Christa; Westh-Andersen, Peter; Jørgensen, Kent

    1999-01-01

    of short-chain alcohols on Lipid bilayers. isothermal titration calorimetry (ITC) has been used to determine the energy involved in the association of the alcohols with lipid bilayers. Pure unilamellar DMPC liposomes and DMPC liposomes incorporated with different amounts of cholesterol, sphingomyelin...... dependent on the lipid bilayer composition. In the presence of high concentrations of cholesterol, the binding enthalpy of ethanol is decreased, whereas the presence of ceramides enhances the enthalpic response of the lipid bilayer to ethanol. Isothermal titration calorimetry offers a new methodology...

  5. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    Science.gov (United States)

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  6. Titration calorimetry of surfactant–drug interactions: Micelle formation and saturation studies

    International Nuclear Information System (INIS)

    Waters, Laura J.; Hussain, Talib; Parkes, Gareth M.B.

    2012-01-01

    Highlights: ► Isothermal titration calorimetry can be used to monitor the saturation of micelles with pharmaceutical compounds. ► The number of drug molecules per micelle varies depending on the drug used and the temperature of the calorimeter. ► The change in enthalpy for the saturation of micelles with drugs can be endothermic or exothermic. ► The critical micellar concentration of an anionic surfactant (SDS) does not appear to vary in the presence of drugs. - Abstract: Isothermal titration calorimetry (ITC) was employed to monitor the addition of five model drugs to anionic surfactant based micelles, composed of sodium dodecyl sulfate (SDS), through to the point at which they were saturated with drug. Analysis of the resultant data using this newly developed method has confirmed the suitability of the technique to acquire such data with saturation limits established in all cases. Values for the point at which saturation occurred ranged from 17 molecules of theophylline per micelle at T = 298 K up to 63 molecules of caffeine per micelle at 310 K. Micellar systems can be disrupted by the presence of additional chemicals, such as the drugs used in this study, therefore a separate investigation was undertaken to determine the critical micellar concentration (CMC) for SDS in the presence of each drug at T = 298 K and 310 K using ITC. In the majority of cases, there was no appreciable alteration to the CMC of SDS with drug present.

  7. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    Science.gov (United States)

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  8. Ln(III)-malate complexation studies using TRLFS and micro titration calorimetry

    International Nuclear Information System (INIS)

    Taube, F.; Drobot, B.; Acker, M.; Taut, S.; Stumpf, Thorsten

    2017-01-01

    The complexation of trivalent lanthanides was studied using Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS) and Isothermal Titration Calorimetry (ITC). Formation constants, complexation enthalpies and fluorescence lifetimes are determined over a wide pH range at I = 0.5 m NaCl. This subject has the following background: Concrete is widely used as engineering barrier and for waste conditioning in waste repositories. Its binding agent is cement. Organic cement additives, which are used to improve the workability of fresh concrete, are complexation agents for radionuclides after they have been released during the concretes degradation. Thus, these additives might have an impact on the aqueous geochemistry of actinides. Here, the α-hydroxydicarboxylic acid or malic acid is examined. It is used in water-reducers or retarders in cement.

  9. Ln(III)-malate complexation studies using TRLFS and micro titration calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Taube, F.; Drobot, B. [Technische Univ. Dresden (Germany). Professorship Radiochemistry; Acker, M.; Taut, S. [Technische Univ. Dresden (Germany). Central Radionuclide Laboratory; Stumpf, Thorsten [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Inst. of Resource Ecology

    2017-06-01

    The complexation of trivalent lanthanides was studied using Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS) and Isothermal Titration Calorimetry (ITC). Formation constants, complexation enthalpies and fluorescence lifetimes are determined over a wide pH range at I = 0.5 m NaCl. This subject has the following background: Concrete is widely used as engineering barrier and for waste conditioning in waste repositories. Its binding agent is cement. Organic cement additives, which are used to improve the workability of fresh concrete, are complexation agents for radionuclides after they have been released during the concretes degradation. Thus, these additives might have an impact on the aqueous geochemistry of actinides. Here, the α-hydroxydicarboxylic acid or malic acid is examined. It is used in water-reducers or retarders in cement.

  10. Determination of the aggregation number for micelles by isothermal titration calorimetry

    DEFF Research Database (Denmark)

    Olesen, Niels Erik; Holm, Rene; Westh, Peter

    2014-01-01

    Isothermal titration calorimetry (ITC) has previously been applied to estimate the aggregation number (n), Gibbs free energy (ΔG), enthalpy (ΔH) and entropy (ΔS) of micellization. However, some difficulties of micelle characterization by ITC still remain; most micelles have aggregation numbers...... insight into optimal design of titration protocols for micelle characterization. By applying the new method, the aggregation number of sodium dodecyl sulphate and glycochenodeoxycholate was determined at concentrations around their critical micelle concentration (CMC)...

  11. Subsite binding energies of an exo-polygalacturonase using isothermal titration calorimetry

    Science.gov (United States)

    Thermodynamic parameters for binding of a series of galacturonic acid oligomers to an exo-polygalacturonase, RPG16 from Rhizopus oryzae, were determined by isothermal titration calorimetry. Binding of oligomers varying in chain length from two to five galacturonic acid residues is an exothermic proc...

  12. Enzyme-catalyzed and binding reaction kinetics determined by titration calorimetry.

    Science.gov (United States)

    Hansen, Lee D; Transtrum, Mark K; Quinn, Colette; Demarse, Neil

    2016-05-01

    Isothermal calorimetry allows monitoring of reaction rates via direct measurement of the rate of heat produced by the reaction. Calorimetry is one of very few techniques that can be used to measure rates without taking a derivative of the primary data. Because heat is a universal indicator of chemical reactions, calorimetry can be used to measure kinetics in opaque solutions, suspensions, and multiple phase systems and does not require chemical labeling. The only significant limitation of calorimetry for kinetic measurements is that the time constant of the reaction must be greater than the time constant of the calorimeter which can range from a few seconds to a few minutes. Calorimetry has the unique ability to provide both kinetic and thermodynamic data. This article describes the calorimetric methodology for determining reaction kinetics and reviews examples from recent literature that demonstrate applications of titration calorimetry to determine kinetics of enzyme-catalyzed and ligand binding reactions. A complete model for the temperature dependence of enzyme activity is presented. A previous method commonly used for blank corrections in determinations of equilibrium constants and enthalpy changes for binding reactions is shown to be subject to significant systematic error. Methods for determination of the kinetics of enzyme-catalyzed reactions and for simultaneous determination of thermodynamics and kinetics of ligand binding reactions are reviewed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Thermodynamic analysis of Bacillus subtilis endospore protonation using isothermal titration calorimetry

    Science.gov (United States)

    Harrold, Zoë R.; Gorman-Lewis, Drew

    2013-05-01

    Bacterial proton and metal adsorption reactions have the capacity to affect metal speciation and transport in aqueous environments. We coupled potentiometric titration and isothermal titration calorimetry (ITC) analyses to study Bacillus subtilis spore-proton adsorption. We modeled the potentiometric data using a four and five-site non-electrostatic surface complexation model (NE-SCM). Heats of spore surface protonation from coupled ITC analyses were used to determine site specific enthalpies of protonation based on NE-SCMs. The five-site model resulted in a substantially better model fit for the heats of protonation but did not significantly improve the potentiometric titration model fit. The improvement observed in the five-site protonation heat model suggests the presence of a highly exothermic protonation reaction circa pH 7 that cannot be resolved in the less sensitive potentiometric data. From the log Ks and enthalpies we calculated corresponding site specific entropies. Log Ks and site concentrations describing spore surface protonation are statistically equivalent to B. subtilis cell surface protonation constants. Spore surface protonation enthalpies, however, are more exothermic relative to cell based adsorption suggesting a different bonding environment. The thermodynamic parameters defined in this study provide insight on molecular scale spore-surface protonation reactions. Coupled ITC and potentiometric titrations can reveal highly exothermic, and possibly endothermic, adsorption reactions that are overshadowed in potentiometric models alone. Spore-proton adsorption NE-SCMs derived in this study provide a framework for future metal adsorption studies.

  14. Applications of isothermal titration calorimetry - the research and technical developments from 2011 to 2015.

    Science.gov (United States)

    Falconer, Robert J

    2016-10-01

    Isothermal titration calorimetry is a widely used biophysical technique for studying the formation or dissociation of molecular complexes. Over the last 5 years, much work has been published on the interpretation of isothermal titration calorimetry (ITC) data for single binding and multiple binding sites. As over 80% of ITC papers are on macromolecules of biological origin, this interpretation is challenging. Some researchers have attempted to link the thermodynamics constants to events at the molecular level. This review highlights work carried out using binding sites characterized using x-ray crystallography techniques that allow speculation about individual bond formation and the displacement of individual water molecules during ligand binding and link these events to the thermodynamic constants for binding. The review also considers research conducted with synthetic binding partners where specific binding events like anion-π and π-π interactions were studied. The revival of assays that enable both thermodynamic and kinetic information to be collected from ITC data is highlighted. Lastly, published criticism of ITC research from a physical chemistry perspective is appraised and practical advice provided for researchers unfamiliar with thermodynamics and its interpretation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Monitoring of an RNA Multistep Folding Pathway by Isothermal Titration Calorimetry

    OpenAIRE

    Reymond, Cédric; Bisaillon, Martin; Perreault, Jean-Pierre

    2009-01-01

    Isothermal titration calorimetry was used to monitor the energetic landscape of a catalytic RNA, specifically that of the hepatitis delta virus ribozyme. Using mutants that isolated various tertiary interactions, the thermodynamic parameters of several ribozyme-substrate intermediates were determined. The results shed light on the impact of several tertiary interactions on the global structure of the ribozyme. In addition, the data indicate that the formation of the P1.1 pseudoknot is the lim...

  16. Proton and Copper Binding to Humic Acids Analyzed by XAFS Spectroscopy and Isothermal Titration Calorimetry

    NARCIS (Netherlands)

    Xu, Jinling; Koopal, Luuk K.; Fang, Linchuan; Xiong, Juan; Tan, Wenfeng

    2018-01-01

    Proton and copper (Cu) binding to soil and lignite-based humic acid (HA) was investigated by combining X-ray absorption fine structure (XAFS) spectroscopy, isothermal titration calorimetry (ITC), and nonideal-competitive-adsorption (NICA) modeling. NICA model calculations and XAFS results showed

  17. Isothermal Titration Calorimetry and Macromolecular Visualization for the Interaction of Lysozyme and Its Inhibitors

    Science.gov (United States)

    Wei, Chin-Chuan; Jensen, Drake; Boyle, Tiffany; O'Brien, Leah C.; De Meo, Cristina; Shabestary, Nahid; Eder, Douglas J.

    2015-01-01

    To provide a research-like experience to upper-division undergraduate students in a biochemistry teaching laboratory, isothermal titration calorimetry (ITC) is employed to determine the binding constants of lysozyme and its inhibitors, N-acetyl glucosamine trimer (NAG[subscript 3]) and monomer (NAG). The extremely weak binding of lysozyme/NAG is…

  18. Understanding binding affinity : A combined isothermal titration calorimetry/molecular dynamics study of the binding of a series of hydrophobically modified benzamidinium chloride inhibitors to trypsin

    NARCIS (Netherlands)

    Talhout, Reinskje; Villa, Alessandra; Mark, AE; Engberts, JBFN

    2003-01-01

    The binding of a series of p-alkylbenzamidinium chloride inhibitors to the serine proteinase trypsin over a range of temperatures has been studied using isothermal titration (micro)calorimetry and molecular dynamics simulation techniques. The inhibitors have small structural variations at the para

  19. A survey of the year 2007 literature on applications of isothermal titration calorimetry

    OpenAIRE

    Bjelic, S; Jelesarov, I

    2008-01-01

    Elucidation of the energetic principles of binding affinity and specificity is a central task in many branches of current sciences: biology, medicine, pharmacology, chemistry, material sciences, etc. In biomedical research, integral approaches combining structural information with in-solution biophysical data have proved to be a powerful way toward understanding the physical basis of vital cellular phenomena. Isothermal titration calorimetry (ITC) is a valuable experimental tool facilitating ...

  20. Isothermal titration calorimetry and surface plasmon resonance allow quantifying substrate binding to different binding sites of Bacillus subtilis xylanase

    DEFF Research Database (Denmark)

    Cuyvers, Sven; Dornez, Emmie; Abou Hachem, Maher

    2012-01-01

    Isothermal titration calorimetry and surface plasmon resonance were tested for their ability to study substrate binding to the active site (AS) and to the secondary binding site (SBS) of Bacillus subtilis xylanase A separately. To this end, three enzyme variants were compared. The first...

  1. Thermodynamic profiling of Peptide membrane interactions by isothermal titration calorimetry: a search for pores and micelles

    DEFF Research Database (Denmark)

    Henriksen, Jonas Rosager; Andresen, Thomas Lars

    2011-01-01

    in mixed peptide-lipid micelles. We have investigated the mode of action of the antimicrobial peptide mastoparan-X using isothermal titration calorimetry (ITC) and cryo-transmission electron microscopy (cryo-TEM). The results show that mastoparan-X induces a range of structural transitions of POPC/POPG (3...

  2. Thermodynamics of ion binding to phosphatidic acid bilayers. Titration calorimetry of the heat of dissociation of DMPA.

    Science.gov (United States)

    Blume, A; Tuchtenhagen, J

    1992-05-19

    The heat of dissociation of the second proton of 1,2-dimyristoylphosphatidic acid (DMPA) was studied as a function of temperature using titration calorimetry. The dissociation of the second proton of DMPA was induced by addition of NaOH. From the calorimetric titration experiment, the intrinsic pK0 for the dissociation reaction could be determined by applying the Gouy-Chapman theory. pK0 decreases with temperature from ca. 6.2 at 11 degrees C to 5.4 at 54 degrees C. From the total heat of reaction, the dissociation enthalpy, delta Hdiss, was determined by subtracting the heat of neutralization of water and the heat of dilution of NaOH. In the temperature range between 2 and 23 degrees C, delta Hdiss is endothermic with an average value of ca. 2.5 kcal.mol-1 and shows no clear-cut temperature dependence. In the temperature range between 23 and 52 degrees C, delta Hdiss calculated after subtraction of the heat of neutralization and dilution is not the true dissociation enthalpy but includes contributions from the phase transition enthalpy, delta Htrans, as the pH jump induces a transition from the gel to the liquid-crystalline phase. The delta Cp for the reaction enthalpy observed in this temperature range is positive. Above 53 degrees C, the pH jump induces again only the dissociation of the second proton, and the bilayers stay in the liquid-crystalline phase. In this temperature range, delta Hdiss seems to decrease with temperature. The thermodynamic data from titration calorimetry and differential scanning calorimetry as a function of pH can be combined to construct a complete enthalpy-temperature diagram of DMPA in its two ionization states.

  3. Thermodynamics of biphasic lanthanide extraction by tripodal diglycolamide: a solution calorimetry study

    NARCIS (Netherlands)

    Ansari, S.A.; Mohapatra, P.K.; Verboom, Willem; Rao, L.

    2016-01-01

    Isothermal titration calorimetry was employed for the direct measurement of the enthalpy of extraction (ΔHextr) of Eu(NO3)3 by using a tripodal diglycolamide (T-DGA) ligand dissolved in n-dodecane containing 5% (v/v) 2-decanol. The enthalpy of extraction obtained by titration calorimetry was in good

  4. Kinetic properties of two Rhizopus exo-polygalacturonase enzymes hydrolyzing galacturonic acid oligomers using isothermal titration calorimetry

    Science.gov (United States)

    The kinetic characteristics of two Rhizopus oryzae exo-polygalacturonases acting on galacturonic acid oligomers (GalpA) were determined using isothermal titration calorimetry (ITC). RPG15 hydrolyzing (GalpA)2 demonstrated a Km of 55 uM and kcat of 10.3 s^-1^ while RPG16 was shown to have greater af...

  5. pytc: Open-Source Python Software for Global Analyses of Isothermal Titration Calorimetry Data.

    Science.gov (United States)

    Duvvuri, Hiranmayi; Wheeler, Lucas C; Harms, Michael J

    2018-05-08

    Here we describe pytc, an open-source Python package for global fits of thermodynamic models to multiple isothermal titration calorimetry experiments. Key features include simplicity, the ability to implement new thermodynamic models, a robust maximum likelihood fitter, a fast Bayesian Markov-Chain Monte Carlo sampler, rigorous implementation, extensive documentation, and full cross-platform compatibility. pytc fitting can be done using an application program interface or via a graphical user interface. It is available for download at https://github.com/harmslab/pytc .

  6. Study of asphaltene precipitation by Calorimetry

    DEFF Research Database (Denmark)

    Verdier, Sylvain Charles Roland; Plantier, Frédéric; Bessières, David

    2007-01-01

    Can calorimetry bring new input to the Current understanding of asphaltene precipitation? In this work, two types of precipitation were studied by means of calorimetry: addition of n-heptane into asphaltene solutions and temperature/pressure variations on a recombined live oil. The first series...... of experiments showed that weak forces determine precipitation. Indeed, isothermal titration calorimetry could not detect any clear signal although this technique can detect low-energy transitions such as liquid-liquid equilibrium and rnicellization. The second series of tests proved that precipitation caused...... by T and P variations is exothermic for this system. Furthermore, the temperature-induced precipitation is accompanied by an increase in the apparent thermal expansivity. Therefore, it seems that these two phase transitions exhibit different calorimetric behaviours and they may not be as similar...

  7. Single-experiment displacement assay for quantifying high-affinity binding by isothermal titration calorimetry.

    Science.gov (United States)

    Krainer, Georg; Keller, Sandro

    2015-04-01

    Isothermal titration calorimetry (ITC) is the gold standard for dissecting the thermodynamics of a biomolecular binding process within a single experiment. However, reliable determination of the dissociation constant (KD) from a single titration is typically limited to the range 100 μM>KD>1 nM. Interactions characterized by a lower KD can be assessed indirectly by so-called competition or displacement assays, provided that a suitable competitive ligand is available whose KD falls within the directly accessible window. However, this protocol is limited by the fact that it necessitates at least two titrations to characterize one high-affinity inhibitor, resulting in considerable consumption of both sample material and time. Here, we introduce a fast and efficient ITC displacement assay that allows for the simultaneous characterization of both a high-affinity ligand and a moderate-affinity ligand competing for the same binding site on a receptor within a single experiment. The protocol is based on a titration of the high-affinity ligand into a solution containing the moderate-affinity ligand bound to the receptor present in excess. The resulting biphasic binding isotherm enables accurate and precise determination of KD values and binding enthalpies (ΔH) of both ligands. We discuss the theoretical background underlying the approach, demonstrate its practical application to metal ion chelation, explore its potential and limitations with the aid of simulations and statistical analyses, and elaborate on potential applications to protein-inhibitor interactions. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Quantifying high-affinity binding of hydrophobic ligands by isothermal titration calorimetry.

    Science.gov (United States)

    Krainer, Georg; Broecker, Jana; Vargas, Carolyn; Fanghänel, Jörg; Keller, Sandro

    2012-12-18

    A fast and reliable quantification of the binding thermodynamics of hydrophobic high-affinity ligands employing a new calorimetric competition experiment is described. Although isothermal titration calorimetry is the method of choice for a quantitative characterization of intermolecular interactions in solution, a reliable determination of a dissociation constant (K(D)) is typically limited to the range 100 μM > K(D) > 1 nM. Interactions displaying higher or lower K(D) values can be assessed indirectly, provided that a suitable competing ligand is available whose K(D) falls within the directly accessible affinity window. This established displacement assay, however, requires the high-affinity ligand to be soluble at high concentrations in aqueous buffer and, consequently, poses serious problems in the study of protein binding involving small-molecule ligands dissolved in organic solvents--a familiar case in many drug-discovery projects relying on compound libraries. The calorimetric competition assay introduced here overcomes this limitation, thus allowing for a detailed thermodynamic description of high-affinity receptor-ligand interactions involving poorly water-soluble compounds. Based on a single titration of receptor into a dilute mixture of the two competing ligands, this competition assay provides accurate and precise values for the dissociation constants and binding enthalpies of both high- and moderate-affinity ligands. We discuss the theoretical background underlying the approach, demonstrate its practical application to metal ion chelation and high-affinity protein-inhibitor interactions, and explore its potential and limitations with the aid of simulations and statistical analyses.

  9. Characteristics and thermodynamics of the interaction of 6-shogaol with human serum albumin as studied by isothermal titration calorimetry

    Directory of Open Access Journals (Sweden)

    Shevin Rizal Feroz

    Full Text Available ABSTRACT The interaction between 6-shogaol, a pharmacologically active ginger constituent, and human serum albumin (HSA, the main in vivo drug transporter, was investigated using isothermal titration calorimetry (ITC. The value of the binding constant, Ka (5.02 ± 1.37 × 104 M−1 obtained for the 6-shogaol-HSA system suggested intermediate affinity. Analysis of the ITC data revealed feasibility of the binding reaction due to favorable enthalpy and entropy changes. The values of the thermodynamic parameters suggested involvement of van der Waals forces, hydrogen bonds and hydrophobic interactions in the 6-shogaol-HSA complex formation.

  10. Combined use of titration calorimetry and spectrofluorimetry for the screening of the acidity of solid catalysts in different liquids

    International Nuclear Information System (INIS)

    Gervasini, Antonella; Auroux, Aline

    2013-01-01

    Graphical abstract: Measurements of acidity of oxides of catalytic importance in various liquids open the possibility to know their effective acidity, which is related with their activity in liquid-heterogeneous catalysis. Titration-calorimetry alone or in connection with spectrofluorimetry is efficient for this scope. - Highlights: • Measurements of acidity of oxides of catalytic importance in various liquids. • Titration-calorimetry alone or in connection with spectrofluorimetry is efficient for this scope. • Effective acidities are expressed by given sample in various liquids. • Nb-containing samples are able to maintain acidity in protic liquids. - Abstract: The effective acid and base surface properties of selected acidic and basic samples of catalytic interest (alumina, titania, zirconia, silica–alumina, niobium oxide, niobium phosphate, boron nitride, and hydrotalcite) were measured by titration with basic and acidic molecular probes (aniline, 2-phenylethylamine, and phenol) in various liquids (cyclohexane, 1,4-dioxane, isopropanol, n-decane, and toluene) with different polar and protic characteristics. The combined use of a reaction calorimeter and a spectrofluorimeter has been performed. The set-up of the coupled technique and the most interesting results are shown here. The study confirmed that the acid–base properties of solids are deeply affected by the nature and properties of the liquid surrounding the samples. Few oxides are able to maintain their surface acidity in highly polar and protic solvents, in particular whose containing niobium. In general, the solvating and coordinative ability of the most polar and protic liquids caused remarkable loss of acidity/basicity of the oxide surfaces

  11. Combined use of titration calorimetry and spectrofluorimetry for the screening of the acidity of solid catalysts in different liquids

    Energy Technology Data Exchange (ETDEWEB)

    Gervasini, Antonella, E-mail: antonella.gervasini@unimi.it [Dipartimento di Chimica, Università degli Studi di Milano, via Camillo Golgi, 19, 20133 Milano (Italy); Auroux, Aline, E-mail: aline.auroux@ircelyon.univ-lyon1.fr [Université Lyon 1, CNRS, UMR 5256, Institut de Recherches sur la Catalyse et l‘Environnement de Lyon (IRCELYON), 2 Avenue A. Einstein, 69626 Villeurbanne (France)

    2013-09-10

    Graphical abstract: Measurements of acidity of oxides of catalytic importance in various liquids open the possibility to know their effective acidity, which is related with their activity in liquid-heterogeneous catalysis. Titration-calorimetry alone or in connection with spectrofluorimetry is efficient for this scope. - Highlights: • Measurements of acidity of oxides of catalytic importance in various liquids. • Titration-calorimetry alone or in connection with spectrofluorimetry is efficient for this scope. • Effective acidities are expressed by given sample in various liquids. • Nb-containing samples are able to maintain acidity in protic liquids. - Abstract: The effective acid and base surface properties of selected acidic and basic samples of catalytic interest (alumina, titania, zirconia, silica–alumina, niobium oxide, niobium phosphate, boron nitride, and hydrotalcite) were measured by titration with basic and acidic molecular probes (aniline, 2-phenylethylamine, and phenol) in various liquids (cyclohexane, 1,4-dioxane, isopropanol, n-decane, and toluene) with different polar and protic characteristics. The combined use of a reaction calorimeter and a spectrofluorimeter has been performed. The set-up of the coupled technique and the most interesting results are shown here. The study confirmed that the acid–base properties of solids are deeply affected by the nature and properties of the liquid surrounding the samples. Few oxides are able to maintain their surface acidity in highly polar and protic solvents, in particular whose containing niobium. In general, the solvating and coordinative ability of the most polar and protic liquids caused remarkable loss of acidity/basicity of the oxide surfaces.

  12. Application of a new method for data analysis of isothermal titration calorimetry in the interaction between human serum albumin and Ni{sup 2+}[Serum albumin; Nickel; Isothermal titration calorimetry; Calorimetric method

    Energy Technology Data Exchange (ETDEWEB)

    Saboury, Ali Akbar. E-mail: saboury@chamran.ut.ac.ir

    2003-12-01

    The interaction of human serum albumin (HAS) with divalent nickel ion was studied by isothermal titration calorimetry (ITC) in 30 mM Tris buffer, pH 7.0. There is a set of eight identical and independent binding sites for nickel ions on the protein at the temperature of 300 K. A new calorimetric data analysis allows the determination of the complete set of thermodynamic parameters. The binding isotherm for nickel-HSA interaction is easily obtained by carrying out two different ITC experiments. In the first experiment, the enthalpy of binding for one mole of nickel ion to one mole of binding site on HSA ({delta}H=-36.5 kJ) is obtained, and is used in a second experiment to determine the binding isotherm and to find the number of binding sites (g=8) and the equilibrium constant (K=0.57 {mu}M{sup -1})

  13. Thermodynamic signature of secondary nano-emulsion formation by isothermal titration calorimetry.

    Science.gov (United States)

    Fotticchia, Iolanda; Fotticchia, Teresa; Mattia, Carlo Andrea; Netti, Paolo Antonio; Vecchione, Raffaele; Giancola, Concetta

    2014-12-09

    The stabilization of oil in water nano-emulsions by means of a polymer coating is extremely important; it prolongs the shelf life of the product and makes it suitable for a variety of applications ranging from nutraceutics to cosmetics and pharmaceutics. To date, an effective methodology to assess the best formulations in terms of thermodynamic stability has yet to be designed. Here, we perform a complete physicochemical characterization based on isothermal titration calorimetry (ITC) compared to conventional dynamic light scattering (DLS) to identify polymer concentration domains that are thermodynamically stable and to define the degree of stability through thermodynamic functions depending upon any relevant parameter affecting the stability itself, such as type of polymer coating, droplet distance, etc. For instance, the method was proven by measuring the energetics in the case of two different biopolymers, chitosan and poly-L-lysine, and for different concentrations of the emulsion coated with poly-L-lysine.

  14. Van ‘t Hoff global analyses of variable temperature isothermal titration calorimetry data

    International Nuclear Information System (INIS)

    Freiburger, Lee A.; Auclair, Karine; Mittermaier, Anthony K.

    2012-01-01

    Highlights: ▶ We developed a global fitting strategy for ITC data collected at multiple temperatures. ▶ This method does not require prior knowledge of the binding mechanism. ▶ Monte Carlo simulations show that the approach improves the accuracy of extracted thermodynamic parameters. ▶ The method is used to study coupled folding/binding in aminoglycoside 6′-N-acetyltransferase-Ii. - Abstract: Isothermal titration calorimetry (ITC) can provide detailed information on the thermodynamics of biomolecular interactions in the form of equilibrium constants, K A , and enthalpy changes, ΔH A . A powerful application of this technique involves analyzing the temperature dependences of ITC-derived K A and ΔH A values to gain insight into thermodynamic linkage between binding and additional equilibria, such as protein folding. We recently developed a general method for global analysis of variable temperature ITC data that significantly improves the accuracy of extracted thermodynamic parameters and requires no prior knowledge of the coupled equilibria. Here we report detailed validation of this method using Monte Carlo simulations and an application to study coupled folding and binding in an aminoglycoside acetyltransferase enzyme.

  15. Efficient Isothermal Titration Calorimetry Technique Identifies Direct Interaction of Small Molecule Inhibitors with the Target Protein.

    Science.gov (United States)

    Gal, Maayan; Bloch, Itai; Shechter, Nelia; Romanenko, Olga; Shir, Ofer M

    2016-01-01

    Protein-protein interactions (PPI) play a critical role in regulating many cellular processes. Finding novel PPI inhibitors that interfere with specific binding of two proteins is considered a great challenge, mainly due to the complexity involved in characterizing multi-molecular systems and limited understanding of the physical principles governing PPIs. Here we show that the combination of virtual screening techniques, which are capable of filtering a large library of potential small molecule inhibitors, and a unique secondary screening by isothermal titration calorimetry, a label-free method capable of observing direct interactions, is an efficient tool for finding such an inhibitor. In this study we applied this strategy in a search for a small molecule capable of interfering with the interaction of the tumor-suppressor p53 and the E3-ligase MDM2. We virtually screened a library of 15 million small molecules that were filtered to a final set of 80 virtual hits. Our in vitro experimental assay, designed to validate the activity of mixtures of compounds by isothermal titration calorimetry, was used to identify an active molecule against MDM2. At the end of the process the small molecule (4S,7R)-4-(4-chlorophenyl)-5-hydroxy-2,7-dimethyl-N-(6-methylpyridin-2-yl)-4,6,7,8 tetrahydrIoquinoline-3-carboxamide was found to bind MDM2 with a dissociation constant of ~2 µM. Following the identification of this single bioactive compound, spectroscopic measurements were used to further characterize the interaction of the small molecule with the target protein. 2D NMR spectroscopy was used to map the binding region of the small molecule, and fluorescence polarization measurement confirmed that it indeed competes with p53.

  16. Evaluation of Staphylococcus aureus DNA aptamer by enzyme-linked aptamer assay and isothermal titration calorimetry.

    Science.gov (United States)

    Bayraç, Ceren; Öktem, Hüseyin Avni

    2017-02-01

    To monitor the specificity of Staphylococcus aureus aptamer (SA-31) against its target cell, we used enzyme-linked aptamer assay. In the presence of target cell, horseradish peroxidase-conjugated streptavidin bound to biotin-labeled SA-31 showed specific binding to S  aureus among 3 different bacteria with limit of detection of 10 3 colony-forming unit per milliliter. The apparent K a was 1.39 μM -1  ± 0.3 μM -1 . The binding of SA-31 to membrane proteins extracted from cell surface was characterized using isothermal titration calorimetry, and the effect of changes in binding temperature and salt concentrations of binding buffer was evaluated based on thermodynamic parameters (K a , ΔH, and ΔG). Since binding of aptamer to its targets solely depends on its 3-dimensional structure under experimental conditions used in selection process, the change in temperature and ion concentration changed the affinity of SA-31 to its target on surface of bacteria. At 4°C, SA-31 did not show an affinity to its target with poor heat change upon injection of membrane fraction to aptamer solution. However, the apparent association constants of SA-31 slightly varied from K a  = 1.56 μM -1  ± 0.69 μM -1 at 25°C to K a  = 1.03 μM -1  ± 0.9 μM -1 at 37°C. At spontaneously occurring exothermic binding reactions, affinities of S aureus aptamer to its target were also 9.44 μM -1  ± 0.38 μM -1 at 50mM, 1.60 μM -1  ± 0.11 μM -1 at 137mM, and 3.28 μM -1  ± 0.46 μM -1 at 200 mM of salt concentration. In this study, it was demonstrated that enzyme-linked aptamer assay and isothermal titration calorimetry were useful tools for studying the fundamental binding mechanism between a DNA aptamer and its target on the outer surface of S aureus. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Binding of Cu(II) ions to peptides studied by fluorescence spectroscopy and isothermal titration calorimetry

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-01-01

    Steady-state and time-resolved fluorescence quenching measurements supported by Isothermal Titration Calorimetry (ITC) were used to study the interactions of Cu2 + with four peptides. Two of them were taken from the N-terminal part of the FBP28 protein (formin binding protein) WW domain: Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr-NH2 (D9) and its mutant Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr-NH2 (D9_M) as well as two mutated peptides from the B3 domain of the immunoglobulin binding protein G derived from Streptococcus: Asp-Val-Ala-Thr-Tyr-Thr-NH2 (J1) and Glu-Val-Ala-Thr-Tyr-Thr-NH2 (J2). The measurements were carried out at 298.15 K in 20 mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution with a pH of 6. The fluorescence of all peptides was quenched by Cu2 + ions. The stoichiometry, conditional stability constants and thermodynamic parameters for the interactions of the Cu2 + ions with D9 and D9_M were determined from the calorimetric data. The values of the conditional stability constants were additionally determined from fluorescence quenching measurements and compared with those obtained from calorimetric studies. There was a good correlation between data obtained from the two techniques. On the other hand, the studies revealed that J1 and J2 do not exhibit an affinity towards metal ions. The obtained results prove that fluorescence quenching experiments may be successfully used in order to determine stability constants of complexes with fluorescent ligands. Finally, based on the obtained results, the coordinating properties of the peptides towards the Cu2 + ions are discussed.

  18. Binding of Cu(II) ions to peptides studied by fluorescence spectroscopy and isothermal titration calorimetry.

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-01-15

    Steady-state and time-resolved fluorescence quenching measurements supported by Isothermal Titration Calorimetry (ITC) were used to study the interactions of Cu(2+) with four peptides. Two of them were taken from the N-terminal part of the FBP28 protein (formin binding protein) WW domain: Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr-NH2 (D9) and its mutant Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr-NH2 (D9_M) as well as two mutated peptides from the B3 domain of the immunoglobulin binding protein G derived from Streptococcus: Asp-Val-Ala-Thr-Tyr-Thr-NH2 (J1) and Glu-Val-Ala-Thr-Tyr-Thr-NH2 (J2). The measurements were carried out at 298.15K in 20mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution with a pH of 6. The fluorescence of all peptides was quenched by Cu(2+) ions. The stoichiometry, conditional stability constants and thermodynamic parameters for the interactions of the Cu(2+) ions with D9 and D9_M were determined from the calorimetric data. The values of the conditional stability constants were additionally determined from fluorescence quenching measurements and compared with those obtained from calorimetric studies. There was a good correlation between data obtained from the two techniques. On the other hand, the studies revealed that J1 and J2 do not exhibit an affinity towards metal ions. The obtained results prove that fluorescence quenching experiments may be successfully used in order to determine stability constants of complexes with fluorescent ligands. Finally, based on the obtained results, the coordinating properties of the peptides towards the Cu(2+) ions are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Biomolecule-nanoparticle interactions: Elucidation of the thermodynamics by isothermal titration calorimetry.

    Science.gov (United States)

    Huang, Rixiang; Lau, Boris L T

    2016-05-01

    Nanomaterials (NMs) are often exposed to a broad range of biomolecules of different abundances. Biomolecule sorption driven by various interfacial forces determines the surface structure and composition of NMs, subsequently governs their functionality and the reactivity of the adsorbed biomolecules. Isothermal titration calorimetry (ITC) is a nondestructive technique that quantifies thermodynamic parameters through in-situ measurement of the heat absorption or release associated with an interaction. This review highlights the recent applications of ITC in understanding the thermodynamics of interactions between various nanoparticles (NPs) and biomolecules. Different aspects of a typical ITC experiment that are crucial for obtaining accurate and meaningful data, as well as the strengths, weaknesses, and challenges of ITC applications to NP research were discussed. ITC reveals the driving forces behind biomolecule-NP interactions and the effects of the physicochemical properties of both NPs and biomolecules by quantifying the crucial thermodynamics parameters (e.g., binding stoichiometry, ΔH, ΔS, and ΔG). Complimentary techniques would strengthen the interpretation of ITC results for a more holistic understanding of biomolecule-NP interactions. The thermodynamic information revealed by ITC and its complimentary characterizations is important for understanding biomolecule-NP interactions that are fundamental to the biomedical and environmental applications of NMs and their toxicological effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Uptake and release protocol for assessing membrane binding and permeation by way of isothermal titration calorimetry.

    Science.gov (United States)

    Tsamaloukas, Alekos D; Keller, Sandro; Heerklotz, Heiko

    2007-01-01

    The activity of many biomolecules and drugs crucially depends on whether they bind to biological membranes and whether they translocate to the opposite lipid leaflet and trans aqueous compartment. A general strategy to measure membrane binding and permeation is the uptake and release assay, which compares two apparent equilibrium situations established either by the addition or by the extraction of the solute of interest. Only solutes that permeate the membrane sufficiently fast do not show any dependence on the history of sample preparation. This strategy can be pursued for virtually all membrane-binding solutes, using any method suitable for detecting binding. Here, we present in detail one example that is particularly well developed, namely the nonspecific membrane partitioning and flip-flop of small, nonionic solutes as characterized by isothermal titration calorimetry. A complete set of experiments, including all sample preparation procedures, can typically be accomplished within 2 days. Analogous protocols for studying charged solutes, virtually water-insoluble, hydrophobic compounds or specific ligands are also considered.

  1. Titration calorimetry of anesthetic-protein interaction: negative enthalpy of binding and anesthetic potency.

    Science.gov (United States)

    Ueda, I; Yamanaka, M

    1997-04-01

    Anesthetic potency increases at lower temperatures. In contrast, the transfer enthalpy of volatile anesthetics from water to macromolecules is usually positive. The transfer decreases at lower temperature. It was proposed that a few selective proteins bind volatile anesthetics with negative delta H, and these proteins are involved in signal transduction. There has been no report on direct estimation of binding delta H of anesthetics to proteins. This study used isothermal titration calorimetry to analyze chloroform binding to bovine serum albumin. The calorimetrically measured delta H cal was -10.37 kJ.mol-1. Thus the negative delta H of anesthetic binding is not limited to signal transduction proteins. The binding was saturable following Fermi-Dirac statistics and is characterized by the Langmuir adsorption isotherms, which is interfacial. The high-affinity association constant, K, was 2150 +/- 132 M-1 (KD = 0.47 mM) with the maximum binding number, Bmax = 3.7 +/- 0.2. The low-affinity K was 189 +/- 3.8 M-1 (KD = 5.29 mM), with a Bmax of 13.2 +/- 0.3. Anesthetic potency is a function of the activity of anesthetic molecules, not the concentration. Because the sign of delta H determines the temperature dependence of distribution of anesthetic molecules, it is irrelevant to the temperature dependence of anesthetic potency.

  2. Higher Order Inclusion Complexes and Secondary Interactions Studied by Global Analysis of Calorimetric Titrations

    DEFF Research Database (Denmark)

    Schönbeck, Jens Christian Sidney; Holm, René; Westh, Peter

    2012-01-01

    This paper investigates the use of isothermal titration calorimetry (ITC) as a tool for studying molecular systems in which weaker secondary interactions are present in addition to a dominant primary interaction. Such systems are challenging since the signal pertaining to the stronger primary......). The results are validated by a 13C NMR titration and negative controls with a bile salt with no secondary binding site (glycocholate) (K = 2.96 ± 0.01 × 103 M–1). The method proved useful for detailed analysis of ITC data and may strengthen its use as a tool for studying molecular systems by advanced binding...

  3. Phosphate sorption by three potential filter materials as assessed by isothermal titration calorimetry.

    Science.gov (United States)

    Lyngsie, Gry; Penn, Chad J; Hansen, Hans C B; Borggaard, Ole K

    2014-10-01

    Phosphorus eutrophication of lakes and streams, coming from drained farmlands, is a serious problem in areas with intensive agriculture. Installation of phosphate (P) sorbing filters at drain outlets may be a solution. The aim of this study was to improve the understanding of reactions involved in P sorption by three commercial P sorbing materials, i.e. Ca/Mg oxide-based Filtralite-P, Fe oxide-based CFH-12 and Limestone in two particle sizes (2-1 mm and 1-0.5 mm), by means of isothermal titration calorimetry (ITC), sorption isotherms, sequential extractions and SEM-EDS. The results indicate that P retention by CFH is due to surface complexation by rapid formation of strong Fe-P bonds. In contrast, retention of P by Filtralite-P and Limestone strongly depends on pH and time and is interpreted due to formation of calcium phosphate precipitate(s). Consequently, CFH can unambiguously be recommended as P retention filter material in drain outlets, whereas the use of Filtralite-P and Limestone has certain (serious) limitations. Thus, Filtralite-P has high capacity to retain P but only at alkaline pH (pH ≥ 10) and P retention by Limestone requires long-time contact and a high ratio between sorbent and sorbate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Simultaneous determination of thermodynamic and kinetic parameters of aminopolycarbonate complexes of cobalt(II) and nickel(II) based on isothermal titration calorimetry data.

    Science.gov (United States)

    Tesmar, Aleksandra; Wyrzykowski, Dariusz; Muñoz, Eva; Pilarski, Bogusław; Pranczk, Joanna; Jacewicz, Dagmara; Chmurzyński, Lech

    2017-04-01

    The influence of the different side chain residues on the thermodynamic and kinetic parameters for complexation reactions of the Co 2 + and Ni 2 + ions has been investigated by using the isothermal titration calorimetry (ITC) technique supported by potentiometric titration data. The study was concerned with the 2 common tripodal aminocarboxylate ligands, namely, nitrilotriacetic acid and N-(2-hydroxyethyl) iminodiacetic acid. Calorimetric measurements (ITC) were run in the 2-(N-morpholino)ethanesulfonic acid hydrate (2-(N-morpholino) ethanesulfonic acid), piperazine-N,N'-bis(2-ethanesulfonic acid), and dimethylarsenic acid buffers (0.1 mol L -1 , pH 6) at 298.15 K. The quantification of the metal-buffer interactions and their incorporation into the ITC data analysis enabled to obtain the pH-independent and buffer-independent thermodynamic parameters (K, ΔG, ΔH, and ΔS) for the reactions under study. Furthermore, the kinITC method was applied to obtain kinetic information on complexation reactions from the ITC data. Correlations, based on kinetic and thermodynamic data, between the kinetics of formation of Co 2 + and Ni 2 + complexes and their thermodynamic stabilities are discussed. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Antihypertensive Effects, Molecular Docking Study, and Isothermal Titration Calorimetry Assay of Angiotensin I-Converting Enzyme Inhibitory Peptides from Chlorella vulgaris.

    Science.gov (United States)

    Xie, Jingli; Chen, Xujun; Wu, Junjie; Zhang, Yanyan; Zhou, Yan; Zhang, Lujia; Tang, Ya-Jie; Wei, Dongzhi

    2018-02-14

    The aim of this work is to explore angiotensin I-converting enzyme (ACE) inhibitory peptides from Chlorella vulgaris (C. vulgaris) and discover the inhibitory mechanism of the peptides. After C. vulgaris proteins were gastrointestinal digested in silico, several ACE inhibitory peptides with C-terminal tryptophan were screened. Among them, two novel noncompetitive ACE inhibitors, Thr-Thr-Trp (TTW) and Val-His-Trp (VHW), exhibited the highest inhibitory activity indicated by IC 50 values 0.61 ± 0.12 and 0.91 ± 0.31 μM, respectively. Both the peptides were demonstrated stable against gastrointestinal digestion and ACE hydrolysis. The peptides were administrated to spontaneously hypertensive rats (SHRs) in the dose 5 mg/kg body weight, and VHW could decrease 50 mmHg systolic blood pressure of SHRs (p < 0.05). Molecular docking displayed that both TTW and VHW formed six hydrogen bonds with active site pockets of ACE. Besides, isothermal titration calorimetry assay discovered that VHW could form more stable complex with ACE than TTW. Therefore, VHW was an excellent ACE inhibitor.

  6. Misuse of thermodynamics in the interpretation of isothermal titration calorimetry data for ligand binding to proteins.

    Science.gov (United States)

    Pethica, Brian A

    2015-03-01

    Isothermal titration calorimetry (ITC) has given a mass of data on the binding of small molecules to proteins and other biopolymers, with particular interest in drug binding to proteins chosen as therapeutic indicators. Interpretation of the enthalpy data usually follows an unsound protocol that uses thermodynamic relations in circumstances where they do not apply. Errors of interpretation include incomplete definitions of ligand binding and equilibrium constants and neglect of the non-ideality of the solutions under study, leading to unreliable estimates of standard free energies and entropies of binding. The mass of reported thermodynamic functions for ligand binding to proteins estimated from ITC enthalpies alone is consequently of uncertain thermodynamic significance and utility. ITC and related experiments to test the protocol assumptions are indicated. A thermodynamic procedure avoiding equilibrium constants or other reaction models and not requiring protein activities is given. The discussion draws attention to the fundamental but neglected relation between the thermodynamic activity and bioactivity of drugs and to the generally unknown thermodynamic status of ligand solutions, which for drugs relates directly to effective therapeutic dosimetry. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Synthesis of a ruthenium(II) bipyridyl complex coordinated by a functionalized Schiff base ligand: characterization, spectroscopic and isothermal titration calorimetry measurements of M2+ binding and sensing (M2+=Ca2+, Mg2+).

    Science.gov (United States)

    Dixit, Namrata; Mishra, Lallan; Mustafi, Sourajit M; Chary, Kandala V R; Houjou, Hirohiko

    2009-07-01

    Bis-[methylsalicylidine-4'benzoic acid]-ethylene (LH2) complexed with cis-Ru(bpy)2Cl(2).2H2O provides a complex of composition [Ru(bpy)2L].2NH4PF6 (1), which has been characterized spectroscopically. Its binding behaviour towards Mg2+ and Ca2+ ions is monitored using 1H NMR titration, isothermal titration calorimetry (ITC) and luminescence microscopy. The luminescent ruthenium complex binds Ca2+ in a more selective manner as compared to Mg2+.

  8. The use of isothermal titration calorimetry to determine the thermodynamics of metal ion binding to low-cost sorbents

    International Nuclear Information System (INIS)

    Karlsen, Vigdis; Heggset, Ellinor Baevre; Sorlie, Morten

    2010-01-01

    The thermodynamics of Al 3+ , Cr 3+ , and Pb 2+ binding to the abundant biopolymer chitin have been determined using isothermal titration calorimetry (ITC) and compared to what is observed for binding to activated carbon. The use of ITC enables the detection of two distinct binding sites on chitin for all three metal ions. For the relative strong binding sites, free energy changes ranges from -37.6 kJ/mol to -41.8 kJ/mol while the same values are from -30.1 kJ/mol to -31.8 kJ/mol for the relative weak binding sites. All binding reactions to chitin are entropically driven. Interactions of the metal ions to activated carbon are best fitted as a single-site binding with relative weak binding with free energy changes from -26.3 kJ/mol to -26.8 kJ/mol.

  9. Study of interactions between hyaluronan and cationic surfactants by means of calorimetry, turbidimetry, potentiometry and conductometry.

    Science.gov (United States)

    Krouská, J; Pekař, M; Klučáková, M; Šarac, B; Bešter-Rogač, M

    2017-02-10

    The thermodynamics of the micelle formation of the cationic surfactants tetradecyltrimethylammonium bromide (TTAB) and cetyltrimethylammonium bromide (CTAB) with and without the addition of hyaluronan of two molecular weights was studied in aqueous solution by titration calorimetry. Macroscopic phase separation, which was detected by calorimetry and also by conductometry, occurs when charges on the surfactant and hyaluronan are balanced. In contrast, turbidimetry and potentiometry showed hyaluronan-surfactant interactions at very low surfactant concentrations. The observed differences between systems prepared with CTAB and TTAB indicate that besides the electrostatic interactions, which probably predominate, hydrophobic effects also play a significant role in hyaluronan interactions with cationic surfactants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. A survey of the year 2007 literature on applications of isothermal titration calorimetry.

    Science.gov (United States)

    Bjelić, Sasa; Jelesarov, Ilian

    2008-01-01

    Elucidation of the energetic principles of binding affinity and specificity is a central task in many branches of current sciences: biology, medicine, pharmacology, chemistry, material sciences, etc. In biomedical research, integral approaches combining structural information with in-solution biophysical data have proved to be a powerful way toward understanding the physical basis of vital cellular phenomena. Isothermal titration calorimetry (ITC) is a valuable experimental tool facilitating quantification of the thermodynamic parameters that characterize recognition processes involving biomacromolecules. The method provides access to all relevant thermodynamic information by performing a few experiments. In particular, ITC experiments allow to by-pass tedious and (rarely precise) procedures aimed at determining the changes in enthalpy and entropy upon binding by van't Hoff analysis. Notwithstanding limitations, ITC has now the reputation of being the "gold standard" and ITC data are widely used to validate theoretical predictions of thermodynamic parameters, as well as to benchmark the results of novel binding assays. In this paper, we discuss several publications from 2007 reporting ITC results. The focus is on applications in biologically oriented fields. We do not intend a comprehensive coverage of all newly accumulated information. Rather, we emphasize work which has captured our attention with originality and far-reaching analysis, or else has provided ideas for expanding the potential of the method. Copyright (c) 2008 John Wiley & Sons, Ltd.

  11. Effect of pH on the complexation of kaempferol-4'-glucoside with three β-cyclodextrin derivatives: isothermal titration calorimetry and spectroscopy study.

    Science.gov (United States)

    Zheng, Yan; Dong, Li-Na; Liu, Min; Chen, Aiju; Feng, Shangcai; Wang, Bingquan; Sun, Dezhi

    2014-01-08

    The utilization of kaempferol and its glycosides in food and pharmaceutical industries could be improved by the formation of inclusion complexes with cyclodextrins at different pH. This study explores the complexation of kaempferol-4'-glucoside with sulfobutyl ether-β-cyclodextrin (SBE-β-CD), hydroxypropyl-β-cyclodextrin (HP-β-CD), and methylated-β-cyclodextrin (M-β-CD) in phosphate buffer solutions of different pH using isothermal titration calorimetry, UV-vis absorption and proton nuclear magnetic resonance spectroscopy at 298.2 K. Experimental results showed that kaempferol-4'-glucoside binds with the three β- cyclodextrins in the same 1:1 stoichiometry. The rank order of stability constants is SBE-β-CD > HP-β-CD > M-β-CD at the same pH level and pH 6.0 > pH 7.4 > pH 9.0 for the same cyclodextrin. The binding of kaempferol-4'-glucoside with the three β-cyclodextrin derivatives is synergistically driven by enthalpy and entropy at pH 6.0 and enthalpy-driven at pH 7.4 and 9.0. The possible inclusion mode was that in the cavity of β-CD is included the planar benzopyranic-4-one part of the kaempferol-4'-glucoside.

  12. The use of isothermal titration calorimetry to assess the solubility enhancement of simvastatin by a range of surfactants

    International Nuclear Information System (INIS)

    Patel, Rajesh; Buckton, Graham; Gaisford, Simon

    2007-01-01

    Surfactants are commonly used to increase the solubility of poorly water soluble drugs but the interactions between drug and surfactant can be complex and quantitative relationships can be hard to derive. One approach is to quantify the thermodynamics of interaction and relate these parameters to known solubility or dissolution rate enhancement data. Isothermal titration calorimetry (ITC) was used to measure the enthalpy and free energy of transfer of a model drug (simvastatin) to a number of surfactant (SDS, HTAB, SDCH and Brij 35) micelles. These data were then compared with the solubility enhancements determined for each surfactant using HPLC assays. As expected, there was correlation between the free energy of transfer for the drug to each surfactant and the solubility enhancement of that surfactant. Although the data set is limited, the results suggest that ITC screening of a range of surfactants against a poorly water soluble drug may allow the selection of the best potential solubilising surfactants

  13. Isothermal Titration Calorimetry and Fluorescence Spectroscopy Study Of Asphaltene Self-Association In Toluene And Interaction With A Model Resin

    DEFF Research Database (Denmark)

    Garcia, Daniel Merino; Andersen, Simon Ivar

    2002-01-01

    This article collects the work performed by Isothermal Titration Caloritnetry (ITC) in the study of the self-association of asphaltenes in toluene solutions. Calorimetric experiments show that asphaltenes, start self-associating at very low concentrations and that the existence of a Critical...... with the results of the titration of three model molecules: nonylphenol, which associates by means of hydrogen bond formation, and coronene and pyrene, which associates by stacking. The results obtained leave open the question about the model-stacking molecules, as it was not possible to elucidate whether they do...

  14. Application of a new method for data analysis of isothermal titration calorimetry in the interaction between human serum albumin and Ni2+

    International Nuclear Information System (INIS)

    Saboury, Ali Akbar.

    2003-01-01

    The interaction of human serum albumin (HAS) with divalent nickel ion was studied by isothermal titration calorimetry (ITC) in 30 mM Tris buffer, pH 7.0. There is a set of eight identical and independent binding sites for nickel ions on the protein at the temperature of 300 K. A new calorimetric data analysis allows the determination of the complete set of thermodynamic parameters. The binding isotherm for nickel-HSA interaction is easily obtained by carrying out two different ITC experiments. In the first experiment, the enthalpy of binding for one mole of nickel ion to one mole of binding site on HSA (ΔH=-36.5 kJ) is obtained, and is used in a second experiment to determine the binding isotherm and to find the number of binding sites (g=8) and the equilibrium constant (K=0.57 μM -1 )

  15. Isothermal titration calorimetric studies of the acid-base properties of poly(N-isopropylacrylamide-co-4-vinylpyridine) cationic polyelectrolyte colloidal microgels

    International Nuclear Information System (INIS)

    Seidel, J.; Pinkrah, V.T.; Mitchell, J.C.; Chowdhry, B.Z.; Snowden, M.J.

    2004-01-01

    Isothermal titration calorimetry (ITC) and potentiometric titration were used to study the protonation properties of the 4-vinylpyridine (4-VP) moiety in cationic poly(N-isopropylacrylamide-co-4-vinylpyridine) colloidal microgels [poly(NIPAM-co-4-VP)]. Calorimetric pH titrations were performed using microgels of different 4-VP content and the influence of ionic strength and counter ions have been examined. The calorimetric titration output consists of several thermal contributions reflecting the complex nature of the interactions in the aqueous microgel dispersions. In contrast to the potentiometric results, the calorimetric titration data could not be completely described by a theoretical model solely taking into account protonation equilibria. Deviations from the proposed model correlate with swelling or shrinking of the gel particles. The calorimetric results also reveal a pronounced counter-ion effect of perchlorate compared to chloride ions. In the presence of perchlorate ions, small secondary thermal effects accompany protonation of the 4-VP moiety due, in part, to kinetically limited conformational changes in the co-polymer microgel

  16. A Universal Method for Fishing Target Proteins from Mixtures of Biomolecules using Isothermal Titration Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, X.; Sun, Q; Kini, R; Sivaraman, J

    2008-01-01

    The most challenging tasks in biology include the identification of (1) the orphan receptor for a ligand, (2) the ligand for an orphan receptor protein, and (3) the target protein(s) for a given drug or a lead compound that are critical for the pharmacological or side effects. At present, several approaches are available, including cell- or animal-based assays, affinity labeling, solid-phase binding assays, surface plasmon resonance, and nuclear magnetic resonance. Most of these techniques are not easy to apply when the target protein is unknown and the compound is not amenable to labeling, chemical modification, or immobilization. Here we demonstrate a new universal method for fishing orphan target proteins from a complex mixture of biomolecules using isothermal titration calorimetry (ITC) as a tracking tool. We took snake venom, a crude mixture of several hundred proteins/peptides, as a model to demonstrate our proposed ITC method in tracking the isolation and purification of two distinct target proteins, a major component and a minor component. Identities of fished out target proteins were confirmed by amino acid sequencing and inhibition assays. This method has the potential to make a significant advancement in the area of identifying orphan target proteins and inhibitor screening in drug discovery and characterization.

  17. Thermodynamic insights into drug-surfactant interactions: Study of the interactions of naporxen, diclofenac sodium, neomycin, and lincomycin with hexadecytrimethylammonium bromide by using isothermal titration calorimetry.

    Science.gov (United States)

    Choudhary, Sinjan; Talele, Paurnima; Kishore, Nand

    2015-08-01

    The success of drug delivery depends on the efficiency of the route of administration, which in turn relies on properties of the drug and its transport vehicle. A quantitative knowledge of association of drugs with transport vehicles is lacking when the latter are in the category of self assembled structures. The work reported in this manuscript addresses the mechanism of partitioning of naproxen, diclofenac sodium, neomycin and lincomycin in the micelles of hexadecytrimethylammonium bromide and that is quantitatively based on the measurement of thermodynamic parameters of interactions by using isothermal titration calorimetry. The addressed mechanism of partitioning is based on the identification of the type of interactions of these drugs with the surfactant micelles and monomers, along with the effect of the former on the micellization properties of the surfactant. The conclusions are based on the interpretation of the values of partitioning constant, standard molar enthalpy change, standard molar entropy change and the stoichiometry of the interaction. The results of this study have implications for deriving guidelines for the target oriented synthesis of new drugs that are to be used for effective delivery via micellar media. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Molecular interaction studies of acetylcholinesterase with potential acetylcholinesterase inhibitors from the root of Rhodiola crenulata using molecular docking and isothermal titration calorimetry methods.

    Science.gov (United States)

    Li, Fa-Jie; Liu, Yuan; Yuan, Yuan; Yang, Bin; Liu, Zhen-Ming; Huang, Lu-Qi

    2017-11-01

    (-)-Epicatechin gallate ((-)-ECG), 1,2,3,4,6-O-pentagalloylglucose (PGG), rhodionin, herbacetin and rhodiosin isolated from the root of Rhodiola crenulata exhibited potent, dose-dependent inhibitory effects on acetylcholinesterase (AChE) with IC 50 ranged from 57.50±5.83 to 2.43±0.34μg/mL. With the aim of explaining the differences in activity of these active ingredients and clarifying how they inhibit AChE, the AChE-inhibitor interactions were further explored using molecular docking and isothermal titration calorimetry (ITC) methods in the present study. Molecular docking studies revealed that all compounds except PGG showed binding energy values ranging from -10.30 to -8.00kcal/mol while the binding energy of galantamine, a known AChE inhibitor, was -9.53kcal/mol; they inhibited the AChE by binding into the ligand pocket with the similar binding pattern to that of galantamine by interacting with Glu199 of AChE. Inhibition constant of these active ingredients had a positive correlation with binding energy. The interaction between AChE and PGG was further evaluated with the ITC method and the results indicated that the PGG-AChE interaction was relevant to AChE concentration. The results revealed a possible mechanism for the AChE inhibition activity of these bioactive ingredients, which may provide some help in lead compounds optimization in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Analysis of the interactions between human serum albumin/amphiphilic penicillin in different aqueous media: an isothermal titration calorimetry and dynamic light scattering study

    International Nuclear Information System (INIS)

    Barbosa, Silvia; Taboada, Pablo; Mosquera, Victor

    2005-01-01

    The complexation process of the amphiphilic penicillins sodium cloxacillin and sodium dicloxacillin with the protein human serum albumin (HSA) in aqueous buffered solutions of pH 4.5 and 7.4 at 25 o C was investigated through isothermal titration calorimetry (ITC) and dynamic light scattering. ITC experiments were carried out in the very dilute regime and showed that although hydrophobic interactions are the leading forces for complexation, electrostatic interactions also play an important role. The possibility of the formation of hydrogen bonds is also deduced from experimental data. The thermodynamic quantities of the binding mechanism, i.e, the enthalpy, ΔHITCi, entropy, ΔSITCi, Gibbs energy, ΔGITCi, binding constant, KITCi and the number of binding sites, n i , were obtained. The binding was saturable and is characterised by Langmuir adsorption isotherms. From ITC data and following a theoretical model, the number of bound and free penicillin molecules was calculated. From Scatchard plots, KITCi and n i were obtained and compared with those from ITC data. The interaction potential between the HSA-penicillin complexes and their stability were determined at pH 7.4 from the dependence of the diffusion coefficients on protein concentration by application of the DLVO colloidal stability theory. The results indicate decreasing stability of the colloidal dispersion of the drug-protein complexes with increase in the concentration of added drug

  20. Strategies for assessing proton linkage to bimolecular interactions by global analysis of isothermal titration calorimetry data

    International Nuclear Information System (INIS)

    Coussens, Nathan P.; Schuck, Peter; Zhao, Huaying

    2012-01-01

    Highlights: ► We demonstrate the usefulness of global analysis of ITC data for proton-linked binding study. ► Various experimental strategies are evaluated for their information content. ► Data at multiple temperatures might improve the precision of binding parameters. ► Methods for detailed error analysis of parameter uncertainties are discussed. ► By global modeling, an uncertainty in molecular concentrations can be accounted for. - Abstract: Isothermal titration calorimetry (ITC) is a traditional and powerful method for studying the linkage of ligand binding to proton uptake or release. The theoretical framework has been developed for more than two decades and numerous applications have appeared. In the current work, we explored strategic aspects of experimental design. To this end, we simulated families of ITC data sets that embed different strategies with regard to the number of experiments, range of experimental pH, buffer ionization enthalpy, and temperature. We then re-analyzed the families of data sets in the context of global analysis, employing a proton linkage binding model implemented in the global data analysis platform SEDPHAT, and examined the information content of all data sets by a detailed statistical error analysis of the parameter estimates. In particular, we studied the impact of different assumptions about the knowledge of the exact concentrations of the components, which in practice presents an experimental limitation for many systems. For example, the uncertainty in concentration may reflect imperfectly known extinction coefficients and stock concentrations or may account for different extents of partial inactivation when working with proteins at different pH values. Our results show that the global analysis can yield reliable estimates of the thermodynamic parameters for intrinsic binding and protonation, and that in the context of the global analysis the exact molecular component concentrations may not be required. Additionally

  1. Characterization of the kinetic and thermodynamic landscape of RNA folding using a novel application of isothermal titration calorimetry

    Science.gov (United States)

    Vander Meulen, Kirk A.; Butcher, Samuel E.

    2012-01-01

    A novel isothermal titration calorimetry (ITC) method was applied to investigate RNA helical packing driven by the GAAA tetraloop–receptor interaction in magnesium and potassium solutions. Both the kinetics and thermodynamics were obtained in individual ITC experiments, and analysis of the kinetic data over a range of temperatures provided Arrhenius activation energies (ΔH‡) and Eyring transition state entropies (ΔS‡). The resulting rich dataset reveals strongly contrasting kinetic and thermodynamic profiles for this RNA folding system when stabilized by potassium versus magnesium. In potassium, association is highly exothermic (ΔH25°C = −41.6 ± 1.2 kcal/mol in 150 mM KCl) and the transition state is enthalpically barrierless (ΔH‡ = −0.6 ± 0.5). These parameters are sigificantly positively shifted in magnesium (ΔH25°C = −20.5 ± 2.1 kcal/mol, ΔH‡ = 7.3 ± 2.2 kcal/mol in 0.5 mM MgCl2). Mixed salt solutions approximating physiological conditions exhibit an intermediate thermodynamic character. The cation-dependent thermodynamic landscape may reflect either a salt-dependent unbound receptor conformation, or alternatively and more generally, it may reflect a small per-cation enthalpic penalty associated with folding-coupled magnesium uptake. PMID:22058128

  2. Microcalorimetric and potentiometric titration studies on the adsorption of copper by extracellular polymeric substances (EPS), minerals and their composites.

    Science.gov (United States)

    Fang, Linchuan; Huang, Qiaoyun; Wei, Xing; Liang, Wei; Rong, Xinming; Chen, Wenli; Cai, Peng

    2010-08-01

    Equilibrium adsorption experiments, isothermal titration calorimetry and potentiometric titration techniques were employed to investigate the adsorption of Cu(II) by extracellular polymeric substances (EPS) extracted from Pseudomonas putida X4, minerals (montmorillonite and goethite) and their composites. Compared with predicted values of Cu(II) adsorption on composites, the measured values of Cu(II) on EPS-montmorillonite composite increased, however, those on EPS-goethite composite decreased. Potentiometric titration results also showed that more surface sites were observed on EPS-montmorillonite composite and less reactive sites were found on EPS-goethite composite. The adsorption of Cu(II) on EPS molecules and their composites with minerals was an endothermic reaction, while that on minerals was exothermic. The positive values of enthalpy change (Delta H) and entropy change (DeltaS) for Cu(II) adsorption on EPS and mineral-EPS composites indicated that Cu(II) mainly interacts with carboxyl and phosphoryl groups as inner-sphere complexes on EPS molecules and their composites with minerals. (c) 2010 Elsevier Ltd. All rights reserved.

  3. [Titration comparative study of TOPINA Tablets in patients with localization related epilepsy: double-blind comparative study by rapid and slow titration methods].

    Science.gov (United States)

    Kaneko, Sunao; Inoue, Yushi; Sasagawa, Mutsuo; Kato, Masaaki

    2012-04-01

    To compare the tolerability and efficacy of two titration methods (rapid and slow titration) for TOPINA Tablets with different dosages and periods of escalation, a double-blind comparative study was conducted in patients with localization-related epilepsy. A total of 183 patients were randomized to either rapid titration (initial dosage 100 mg/day increased by 100-200 mg at weekly intervals) or to slow titration (initial dosage 50 mg/day increased in 50 mg/day increments at weekly intervals). TOPINA Tablets were administered for 12 weeks to the maximum dosage of 400 mg/day. The incident of adverse events leading to treatment interruptions or withdrawals was 18.9% in rapid titration and 14.8% in slow titration, with no statistical significance (p = 0.554). The incident of adverse events and adverse reactions of slow titration was slightly lower than that of rapid titration. The common adverse events and adverse reactions reported in the two titration methods were comparable and were well tolerated. On the other hand, the efficacy of slow titration, percent reduction in seizure rate and responder rate, was comparable with that of rapid titration. In conclusion, there were no significant differences of therapeutic response to TOPINA Tablets between the two titration methods.

  4. Comparison of calorimetry and destructive analytical measurement techniques for excess plutonium powders

    International Nuclear Information System (INIS)

    Welsh, T.L.

    1996-01-01

    In Dec. 1994, IAEA safeguards were initiated on inventory of Pu- bearing materials, originating from the US nuclear weapons complex, at vault 3 of DOE's Plutonium Finishing Plant at Hanford. Because of the diversity and heterogeneity of the Pu, plant operators have increasingly used calorimetry for accountability measurements. During the recent commencement of IAEA safeguards at vault 3, destructive (electrochemical titration) methods were used to determine Pu concentrations in subsamples of inventory items with widely ranging chemical purities. The Pu concentrations in the subsamples were determined and contribution of heterogeneity to total variability was identified. Measurement results, gathered by PFP and IAEA laboratories, showed total measurement variability for calorimetry to be comparable with or lower than those of sampling and chemical analyses

  5. Thermodynamics of Surfactants, Block Copolymers and Their Mixtures in Water: The Role of the Isothermal Calorimetry

    Science.gov (United States)

    De Lisi, Rosario; Milioto, Stefania; Muratore, Nicola

    2009-01-01

    The thermodynamics of conventional surfactants, block copolymers and their mixtures in water was described to the light of the enthalpy function. The two methodologies, i.e. the van’t Hoff approach and the isothermal calorimetry, used to determine the enthalpy of micellization of pure surfactants and block copolymers were described. The van’t Hoff method was critically discussed. The aqueous copolymer+surfactant mixtures were analyzed by means of the isothermal titration calorimetry and the enthalpy of transfer of the copolymer from the water to the aqueous surfactant solutions. Thermodynamic models were presented to show the procedure to extract straightforward molecular insights from the bulk properties. PMID:19742173

  6. Exploring variation in binding of Protein A and Protein G to immunoglobulin type G by isothermal titration calorimetry

    DEFF Research Database (Denmark)

    Lund, L. N.; Christensen, T.; Toone, E.

    2011-01-01

    ligands and for the establishment of generic processes for the purification of various antibodies. In this paper, the interactions between the two IgG-binding proteins and IgG of two different subclasses, IgG1 and IgG4, as well as their analogous Fc fragments have been studied by isothermal titration...

  7. Continuing Studies on Lead/Scintillating Fibres Calorimetry (LFC)

    CERN Multimedia

    2002-01-01

    Starting from the results obtained in the framework of the LAA Project~2B, we propose a continuation of the R&D on lead/scintillating fibres calorimetry (``spaghetti calorimetry''), including further tests on the old calorimeter prototypes and the construction and testing of new prototypes. The main results we pursue concern the performances of a projective calorimeter built with new, cheaper, techniques and the radiation hardness of the scintillating fibres, the optimization of a preshower detector system is also studied.

  8. Thermodynamic signatures of fragment binding: Validation of direct versus displacement ITC titrations.

    Science.gov (United States)

    Rühmann, Eggert; Betz, Michael; Fricke, Marie; Heine, Andreas; Schäfer, Martina; Klebe, Gerhard

    2015-04-01

    Detailed characterization of the thermodynamic signature of weak binding fragments to proteins is essential to support the decision making process which fragments to take further for the hit-to-lead optimization. Isothermal titration calorimetry (ITC) is the method of choice to record thermodynamic data, however, weak binding ligands such as fragments require the development of meaningful and reliable measuring protocols as usually sigmoidal titration curves are hardly possible to record due to limited solubility. Fragments can be titrated either directly under low c-value conditions (no sigmoidal curve) or indirectly by use of a strong binding ligand displacing the pre-incubated weak fragment from the protein. The determination of Gibbs free energy is reliable and rather independent of the applied titration protocol. Even though the displacement method achieves higher accuracy, the obtained enthalpy-entropy profile depends on the properties of the used displacement ligand. The relative enthalpy differences across different displacement experiments reveal a constant signature and can serve as a thermodynamic fingerprint for fragments. Low c-value titrations are only reliable if the final concentration of the fragment in the sample cell exceeds 2-10 fold its K(D) value. Limited solubility often prevents this strategy. The present study suggests an applicable protocol to characterize the thermodynamic signature of protein-fragment binding. It shows however, that such measurements are limited by protein and fragment solubility. Deviating profiles obtained by use of different displacement ligands indicate that changes in the solvation pattern and protein dynamics most likely take influence on the resulting overall binding signature. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Mechanism of melatonin protection against copper-ascorbate-induced oxidative damage in vitro through isothermal titration calorimetry.

    Science.gov (United States)

    Ghosh, Arnab K; Naaz, Shamreen; Bhattacharjee, Bharati; Ghosal, Nirajan; Chattopadhyay, Aindrila; Roy, Souvik; Reiter, Russel J; Bandyopadhyay, Debasish

    2017-07-01

    Involvement of oxidative stress in cardiovascular diseases is well established. Melatonin's role as an antioxidant and free radical scavenger via its receptor dependent and receptor independent pathways is well known. The aim of this study is to identify and elaborate upon a third mechanism by which melatonin is able to abrogate oxidative stress. Oxidative stress was induced in vitro, by copper (0.2mM)-ascorbate (1mM) in isolated goat heart mitochondria, cytosol and peroxisomes and they were co-incubated with graded doses of melatonin. Similar experiments in a cell-free chemical system involving two pure antioxidant enzymes, Cu-Zn superoxide dismutase and catalase was also carried out. Biochemical changes in activity of these antioxidant enzymes were analysed. Isothermal titration calorimetric studies with pure Cu-Zn superoxide dismutase and catalase were also carried out. Incubation with copper-ascorbate led to alteration in activity of Cu-Zn superoxide dismutase and catalase which were found to be protected upon co-incubation with melatonin (80μM for catalase and 1μM for others). Results of isothermal titration calorimetric studies with pure Cu-Zn superoxide dismutase and catalase along with different combinations of copper chloride, ascorbic acid and melatonin suggest that when melatonin is present in the reaction medium along with copper-ascorbate, it restrains the copper-ascorbate molecules by binding with them physically along with scavenging the free radicals generated by them. The present study suggests that possibly, binding of melatonin with antioxidant enzymes masks the vulnerable sites of these antioxidant enzymes, thus preventing oxidative damage by copper-ascorbate molecules. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Isothermal titration calorimetry in nanoliter droplets with subsecond time constants.

    Science.gov (United States)

    Lubbers, Brad; Baudenbacher, Franz

    2011-10-15

    We reduced the reaction volume in microfabricated suspended-membrane titration calorimeters to nanoliter droplets and improved the sensitivities to below a nanowatt with time constants of around 100 ms. The device performance was characterized using exothermic acid-base neutralizations and a detailed numerical model. The finite element based numerical model allowed us to determine the sensitivities within 1% and the temporal dynamics of the temperature rise in neutralization reactions as a function of droplet size. The model was used to determine the optimum calorimeter design (membrane size and thickness, junction area, and thermopile thickness) and sensitivities for sample volumes of 1 nL for silicon nitride and polymer membranes. We obtained a maximum sensitivity of 153 pW/(Hz)(1/2) for a 1 μm SiN membrane and 79 pW/(Hz)(1/2) for a 1 μm polymer membrane. The time constant of the calorimeter system was determined experimentally using a pulsed laser to increase the temperature of nanoliter sample volumes. For a 2.5 nanoliter sample volume, we experimentally determined a noise equivalent power of 500 pW/(Hz)(1/2) and a 1/e time constant of 110 ms for a modified commercially available infrared sensor with a thin-film thermopile. Furthermore, we demonstrated detection of 1.4 nJ reaction energies from injection of 25 pL of 1 mM HCl into a 2.5 nL droplet of 1 mM NaOH. © 2011 American Chemical Society

  11. Characterization of the 1st and 2nd EF-hands of NADPH oxidase 5 by fluorescence, isothermal titration calorimetry, and circular dichroism

    Directory of Open Access Journals (Sweden)

    Wei Chin-Chuan

    2012-04-01

    Full Text Available Abstract Background Superoxide generated by non-phagocytic NADPH oxidases (NOXs is of growing importance for physiology and pathobiology. The calcium binding domain (CaBD of NOX5 contains four EF-hands, each binding one calcium ion. To better understand the metal binding properties of the 1st and 2nd EF-hands, we characterized the N-terminal half of CaBD (NCaBD and its calcium-binding knockout mutants. Results The isothermal titration calorimetry measurement for NCaBD reveals that the calcium binding of two EF-hands are loosely associated with each other and can be treated as independent binding events. However, the Ca2+ binding studies on NCaBD(E31Q and NCaBD(E63Q showed their binding constants to be 6.5 × 105 and 5.0 × 102 M-1 with ΔHs of -14 and -4 kJ/mol, respectively, suggesting that intrinsic calcium binding for the 1st non-canonical EF-hand is largely enhanced by the binding of Ca2+ to the 2nd canonical EF-hand. The fluorescence quenching and CD spectra support a conformational change upon Ca2+ binding, which changes Trp residues toward a more non-polar and exposed environment and also increases its α-helix secondary structure content. All measurements exclude Mg2+-binding in NCaBD. Conclusions We demonstrated that the 1st non-canonical EF-hand of NOX5 has very weak Ca2+ binding affinity compared with the 2nd canonical EF-hand. Both EF-hands interact with each other in a cooperative manner to enhance their Ca2+ binding affinity. Our characterization reveals that the two EF-hands in the N-terminal NOX5 are Ca2+ specific. Graphical abstract

  12. Microculture virus titration--a simple colourimetric assay for influenza virus titration.

    Science.gov (United States)

    Levi, R; Beeor-Tzahar, T; Arnon, R

    1995-03-01

    Influenza antigens can be detected by several well established methods. However, when it is important to determine the titre of infective virions, a bioassay should be employed. The standard and the most widely used tests for influenza infectivity are titration carried out in embryonated hen eggs, or the plaque assay employing tissue culture techniques. A simple colourimetric assay for influenza virus detection and titration is described. Samples of allantoic fluid or mice lung homogenates were used to infect MDCK cultures in microplate wells. After an incubation period, the tetrazolium (MTT) colourimetric assay was used to determine cell viability, and when compared to untreated culture control enabled the detection and titration of several influenza strains. When samples were assayed simultaneously in embryonated eggs and by the MCVT method, good correlation in determined titres was obtained. The availability of an additional method for influenza titration allows more flexibility in the choice of titration method according to the specific needs of the study. Furthermore, this method lends itself to full automatization. Similar procedures should also be applicable to titration of other cytopathic viruses.

  13. Thermodynamic study of the interaction between calcium and zoledronic acid by calorimetry

    International Nuclear Information System (INIS)

    Mostefa Side Larbi, Mohamed A.; Sauzet, Christophe; Piccerelle, Philippe; Cau, Pierre

    2016-01-01

    Bisphosphonates (BPs) are widely used to treat calcium disorders because of their structural and functional similarities with the organic pyrophosphates present in plasma and urine. BPs are well known for their strong interactions with calcium, and they have been shown to bind to hydroxyapatite or bone; however, no model exists for studying in greater detail how BPs and particularly amino-bisphosphonates (N-BPs) such as zolendronate (Zol) bind to free calcium. The aim of this work was to determine the effect of pH on Ca 2+ /Zol complex formation using isothermal titration calorimetry (ITC) because these effects might have important implications for the future development of a solid dosage form. In this study, using a predictive model, we can observe, the existence of three Ca 2+ /Zol complexes. Knowledge of the binding constant for each complex is helpful for predicting the predominance of the different species at different Ca 2+ /Zol ratios. Binding is due to ionic interaction between Ca 2+ and the negative charges formed by dissociated Zol as a function of the pKa. Ca 2+ fixation induces a strong rearrangement of the surrounding water molecules and causes proton release or uptake. The pH-dependent affinity of calcium for each site based on the model used in this work is proposed in detail, which might facilitate the development of new bisphosphonates and enable further elucidation of their mode of action.

  14. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    Science.gov (United States)

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  15. Isoperibolic titration calorimetry as a tool for the prediction of thermodynamic properties of cyclodextrins

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Pirajan, J. C. [Universidad de los Andes, Bogota, Grupo de investigacion en solidos porosos y calorimetria, Departamento de Quimica, Facultad de Ciencias / Carrera 1 No.18 A10, Bogota (Colombia); Giraldo, L. [Universidad Nacional de Colombia, Facultad de Ciencias, Departamento de Quimica / Ciudad Universitaria, Bogota (Colombia)

    2008-07-01

    The interaction of guest molecules ranging from pentan-1-ol to octan-1-ol with {alpha}-cyclodextrin ({alpha}-CD) in water of has been studied calorimetrically at 283.15, 288.15, 293.15, 298.15 and 308.15 K with an isoperibolic titration calorimeter designed in our laboratory. The calorimetric method employed allows the determination of the thermodynamic parameters characterizing the binding process, {delta}G {sup o}{sub m}, {delta}H {sup o}{sub m}, {delta}S {sup o}{sub m} and {delta}Cp {sup o}, namely free energy, enthalpy, and calorific capacity. These results show that in the temperature range investigated, the entropy change increased with chain length. This is in line with what is expected for a hydrophobic dehydration process. However, that effect is not expected to lead to the more pronounced negative CH{sub 2}-increment observed for n{sub c} > 5 or 6. As for many other ligand binding processes, we can observe a significant enthalpy - entropy compensation for this system, both with respect to temperature and structure. (author)

  16. Is automatic CPAP titration as effective as manual CPAP titration in OSAHS patients? A meta-analysis.

    Science.gov (United States)

    Gao, Weijie; Jin, Yinghui; Wang, Yan; Sun, Mei; Chen, Baoyuan; Zhou, Ning; Deng, Yuan

    2012-06-01

    It is costly and time-consuming to conduct the standard manual titration to identify an effective pressure before continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) patients. Automatic titration is cheaper and more easily available than manual titration. The purpose of this systematic review was to evaluate the effect of automatic titration in identifying a pressure and on the improvement of apnea/hyponea index (AHI) and somnolence, the change of sleep quality, and the acceptance and compliance of CPAP treatment, compared with the manual titration. A systematic search was made of the PubMed, EMBASE, Cochrane Library, SCI, China Academic Journals Full-text Databases, Chinese Biomedical Literature Database, Chinese Scientific Journals Databases and Chinese Medical Association Journals. Randomized controlled trials comparing automatic titration and manual titration were reviewed. Studies were pooled to yield odds ratios (OR) or mean differences (MD) with 95% confidence intervals (CI). Ten trials involving 849 patients met the inclusion criteria. It is hard to identify a trend in the pressures determined by either automatic or manual titration. Automatic titration can improve the AHI (MD = 0.03/h, 95% CI = -4.48 to 4.53) and Epworth sleepiness scale (SMD = -0.02, 95% CI = -0.34 to 0.31,) as effectively as the manual titration. There is no difference between sleep architecture under automatic titration or manual titration. The acceptance of CPAP treatment (OR = 0.96, 95% CI = 0.60 to 1.55) and the compliance with treatment (MD = -0.04, 95% CI = -0.17 to 0.10) after automatic titration is not different from manual titration. Automatic titration is as effective as standard manual titration in improving AHI, somnolence while maintaining sleep quality similar to the standard method. In addition, automatic titration has the same effect on the acceptance and compliance of CPAP treatment as manual titration. With the potential advantage

  17. Isoperibolic Titration Calorimetry as a Tool for the Prediction of Thermodynamic Properties of Cyclodextrins

    Directory of Open Access Journals (Sweden)

    Liliana Giraldo

    2008-10-01

    Full Text Available The interaction of guest molecules ranging from pentan-1-ol to octan-1-ol with α-cyclodextrin (α-CD in water of has been studied calorimetrically at 283.15, 288.15, 293.15, 298.15 and 308.15 K with an isoperibolic titration calorimeter designed in our laboratory. The calorimetric method employed allows the determination of the thermodynamic parameters characterizing the binding process, ΔG°m, ΔH°m, ΔS°mand ΔCp°, namely free energy, enthalpy, and calorific capacity. These results show that in the temperature range investigated, the entropy change increased with chain length. This is in line with what is expected for a hydrophobic dehydration process. However, that effect is not expected to lead to the more pronounced negative CH2-increment observed for nc > 5 or 6. As for many other ligand binding processes, we can observe a significant enthalpy - entropy compensation for this system, both with respect to temperature and structure.

  18. Calorimetry

    International Nuclear Information System (INIS)

    Pope, B.

    1983-01-01

    An overall review of properties of various types of calorimeters is given, with special attention given to the challenges of high luminosity and high energy. The calorimeters described include continuous calorimeters, scintillation sampling calorimetry, gas sampling calorimetry, and liquid ionization calorimeters. Next explored are some limiting factors involved in experiments at high luminosities (or at high energies), and some examples are offered of detectors capable of operating at the highest luminosities (energies). Specific areas where substantial research and development work is needed are itemized

  19. Calorimetry for the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, H.A.; Grannis, P.D.

    1984-01-01

    The activities related to calorimetry at Snowmass took place in three main areas. These were: (1) The performance criteria for SSC calorimetry, including the requirements on hermeticity, shower containment, segmentation and time resolution. The use of calorimetric means of particle identification was studied. (2) The study of triggering methods using calorimeter energy, angle and timing information. (3) A review of a wide variety of calorimeter materials for absorber and sampling, as well as several means of obtaining the readout of the energy deposits. 48 references, 10 figures, 1 table.

  20. Calorimetry for the SSC

    International Nuclear Information System (INIS)

    Gordon, H.A.; Grannis, P.D.

    1984-01-01

    The activities related to calorimetry at Snowmass took place in three main areas. These were: (1) The performance criteria for SSC calorimetry, including the requirements on hermeticity, shower containment, segmentation and time resolution. The use of calorimetric means of particle identification was studied. (2) The study of triggering methods using calorimeter energy, angle and timing information. (3) A review of a wide variety of calorimeter materials for absorber and sampling, as well as several means of obtaining the readout of the energy deposits. 48 references, 10 figures, 1 table

  1. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  2. Calorimetry of non-reacting systems

    CERN Document Server

    McCullough, John P

    2013-01-01

    Experimental Thermodynamics, Volume 1: Calorimetry of Non-Reacting Systems covers the heat capacity determinations for chemical substances in the solid, liquid, solution, and vapor states, at temperatures ranging from near the absolute zero to the highest at which calorimetry is feasible.This book is divided into 14 chapters. The first four chapters provide background information and general principles applicable to all types of calorimetry of non-reacting systems. The remaining 10 chapters deal with specific types of calorimetry. Most of the types of calorimetry treated are developed over a c

  3. Thermometric titration of sulphate.

    Science.gov (United States)

    Williams, M B; Janata, J

    1970-06-01

    Direct thermometric titration of sulphate with a solution of barium perchlorate is proposed. The stoichiometry of the titration is shown to be critically dependent on the concentration of ethanol in the titration medium. The titration is rapid and suffers from only a few interferences.

  4. Theory of titration curves-VII The properties of derivative titration curves for strong acid-strong base and other isovalent ion-combination titrations.

    Science.gov (United States)

    Meites, T; Meites, L

    1970-06-01

    This paper deals with isovalent ion-combination titrations based on reactions that can be represented by the equation M(n+) + X(n-) --> MX, where the activity of the product MX is invariant throughout a titration, and with the derivative titration curves obtained by plotting d[M(+)]/dfversus f for such titrations. It describes some of the ways in which such curves can be obtained; it compares and contrasts them both with potentiometric titration curves, which resemble them in shape, and with segmented titration curves, from which they are derived; and it discusses their properties in detail.

  5. The SimpleMix study with biphasic insulin aspart 30: a randomized controlled trial investigating patient-driven titration versus investigator-driven titration.

    Science.gov (United States)

    Gao, Yan; Luquez, Cecilia; Lynggaard, Helle; Andersen, Henning; Saboo, Banshi

    2014-12-01

    The study aimed to confirm the efficacy, through non-inferiority, of patient-driven versus investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) in terms of glycemic control assessed by HbA1c change. SimpleMix was a 20 week, open-label, randomized, two-armed, parallel-group, multicenter study in five countries (Argentina, China, India, Poland, and the UK). Patients with type 2 diabetes were randomized into either patient-driven or investigator-driven BIAsp 30 titration groups. Non-inferiority of patient-driven vs. investigator-driven titration based on change in HbA1c from baseline to week 20 could not be demonstrated. Mean (SE) estimated change from baseline to week 20 was -0.72 (0.08)% in the patient-driven group and -0.97 (0.08)% in the investigator-driven group; estimated difference 0.25% (95% CI: 0.04; 0.46). Estimated mean change (SE) in fasting plasma glucose from baseline to week 20 was similar between groups: -0.94 (0.21) mmol/L for patient-driven and -1.07 (0.22) mmol/L for investigator-driven (difference non-significant). Both treatment arms were well tolerated, and hypoglycemic episode rates were similar between groups, with a rate ratio of 0.77 (95% CI: 0.54; 1.09; p = 0.143) for all hypoglycemic episodes and 0.78 (95% CI: 0.42; 1.43; p = 0.417) for nocturnal hypoglycemic episodes. Non-inferiority of patient-driven versus investigator-driven titration with regard to change from baseline to end-of-treatment HbA1c could not be confirmed. It is possible that a clinic visit 12 weeks after intensification of treatment with BIAsp 30 in patients with type 2 diabetes inadequately treated with basal insulin may benefit patient-driven titration of BIAsp 30. A limitation of the study was the relatively small number of patients recruited in each country, which does not allow country-specific analyses to be performed. Overall, treatment with BIAsp 30 was well tolerated in both treatment groups.

  6. Contributions to the theory of catalytic titrations-III Neutralization catalytic titrations.

    Science.gov (United States)

    Gaál, F F; Abramović, B F

    1985-07-01

    Neutralization catalytic titrations of weak monoprotic adds and bases with both volumetric and coulometric addition of the titrant (strong base/acid) have been simulated by taking into account the equilibrium concentration of the catalyst during the titration. The influence of several factors on the shape of the simulated catalytic titration curve has been investigated and is discussed.

  7. Monte Carlo studies of uranium calorimetry

    International Nuclear Information System (INIS)

    Brau, J.; Hargis, H.J.; Gabriel, T.A.; Bishop, B.L.

    1985-01-01

    Detailed Monte Carlo calculations of uranium calorimetry are presented which reveal a significant difference in the responses of liquid argon and plastic scintillator in uranium calorimeters. Due to saturation effects, neutrons from the uranium are found to contribute only weakly to the liquid argon signal. Electromagnetic sampling inefficiencies are significant and contribute substantially to compensation in both systems. 17 references

  8. Micellization of bovine beta-casein studied by isothermal titration microcalorimetry and cryogenic transmission electron microscopy.

    Science.gov (United States)

    Portnaya, Irina; Cogan, Uri; Livney, Yoav D; Ramon, Ory; Shimoni, Karin; Rosenberg, Moshe; Danino, Dganit

    2006-07-26

    The association behavior, critical micellization concentration (CMC), and enthalpy of demicellization (DeltaHdemic) of bovine beta-casein were studied, for the first time by isothermal titration calorimetry, in a pH 7.0 phosphate buffer with 0.1 ionic strength and in pure water. In the buffer solutions, the CMC decreased asymptotically from 0.15 to 0.006 mM as the temperature was raised from 16 to 45 degrees C. DeltaHdemic decreased with increasing temperature between 16 and 28 degrees C but increased from 28 to 45 degrees C. Thermodynamic analysis below 30 degrees C is consistent with the Kegeles shell model, which suggests a stepwise association process. At higher temperatures, this model exhibits limitations, and the micellization becomes much more cooperative. The CMC values in water, measured between 17 and 28 degrees C, decreased with increasing temperature and, expectedly, were higher than those found in the buffer solutions. beta-Casein micelles were visualized and characterized, for the first time in their hydrated state, using advanced digital-imaging cryogenic transmission electron microscopy. The images revealed small, oblate micelles, about approximately 13 nm in diameter. The micelles shape and dimensions remained nearly constant in the temperature range of 24-35 degrees C.

  9. Probing the binding of Cu(2+) ions to a fragment of the Aβ(1-42) polypeptide using fluorescence spectroscopy, isothermal titration calorimetry and molecular dynamics simulations.

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Żmudzińska, Wioletta; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-09-01

    Steady-state and time-resolved fluorescence quenching measurements supported by isothermal titration calorimetry (ITC) and molecular dynamics simulations (MD), with the NMR-derived restraints, were used to investigate the interactions of Cu(2+) ions with a fragment of the Aβ(1-42) polypeptide, Aβ(5-16) with the following sequence: Ac-Arg-His-Asp-Ser-Gly-Tyr-Glu-Val-His-His-Gln-Lys-NH2, denoted as HZ1. The studies presented in this paper, when compared with our previous results (Makowska et al., Spectrochim. Acta A 153: 451-456), show that the affinity of the peptide to metal ions is conformation-dependent. All the measurements were carried out in 20mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution, pH6.0. The Stern-Volmer equations, along with spectroscopic observations, were used to determine the quenching and binding parameters. The obtained results unequivocally suggest that Cu(2+) ions quench the fluorescence of HZ1 only through a static quenching mechanism, in contrast to the fragment from the N-terminal part of the FPB28 protein, with sequence Ac-Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr- NH2 (D9) and its derivative with a single point mutation: Ac-Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr- NH2 (D9_M), where dynamic quenching occurred. The thermodynamic parameters (ΔITCH, ΔITCS) for the interactions between Cu(2+) ions and the HZ1 peptide were determined from the calorimetric data. The conditional thermodynamic parameters suggest that, under the experimental conditions, the formation of the Cu(2+)-HZ1 complex is both an enthalpy and entropy driven process. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  11. LIGHT TITRATIONS

    Science.gov (United States)

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  12. Microcalorimetric and potentiometric titration studies on the adsorption of copper by P. putida and B. thuringiensis and their composites with minerals

    International Nuclear Information System (INIS)

    Fang Linchuan; Cai Peng; Li Pengxiang; Wu Huayong; Liang Wei; Rong Xingmin; Chen Wenli; Huang Qiaoyun

    2010-01-01

    In order to have a better understanding of the interactions of heavy metals with bacteria and minerals in soil and associated environments, isothermal titration calorimetry (ITC), potentiometric titration and equilibrium sorption experiments were conducted to investigate the adsorption behavior of Cu(II) by Bacillus thuringiensis, Pseudomonas putida and their composites with minerals. The interaction of montmorillonite with bacteria increased the reactive sites and resulted in greater adsorption for Cu(II) on their composites, while decreased adsorption sites and capacities for Cu(II) were observed on goethite-bacteria composites. A gram-positive bacterium B. thuringiensis played a more important role than a gram-negative bacterium P. putida in determining the properties of the bacteria-minerals interfaces. The enthalpy changes (ΔH ads ) from endothermic (6.14 kJ mol -1 ) to slightly exothermic (-0.78 kJ mol -1 ) suggested that Cu(II) is complexed with the anionic oxygen ligands on the surface of bacteria-mineral composites. Large entropies (32.96-58.89 J mol -1 K -1 ) of Cu(II) adsorption onto bacteria-mineral composites demonstrated the formation of inner-sphere complexes in the presence of bacteria. The thermodynamic data implied that Cu(II) mainly bound to the carboxyl and phosphoryl groups as inner-sphere complexes on bacteria and mineral-bacteria composites.

  13. Recent developments in silicon calorimetry

    International Nuclear Information System (INIS)

    Brau, J.E.

    1990-11-01

    We present a survey of some of the recent calorimeter applications of silicon detectors. The numerous attractive features of silicon detectors are summarized, with an emphasis on those aspects important to calorimetry. Several of the uses of this technology are summarized and referenced. We consider applications for electromagnetic calorimetry, hadronic calorimetry, and proposals for the SSC

  14. An interaction of the functionalized closo-borates with albumins: The protein fluorescence quenching and calorimetry study

    International Nuclear Information System (INIS)

    Losytskyy, Mykhaylo Yu.; Kovalska, Vladyslava B.; Varzatskii, Oleg A.; Kuperman, Marina V.; Potocki, Slawomir; Gumienna-Kontecka, Elzbieta; Zhdanov, Andrey P.; Yarmoluk, Sergiy M.; Voloshin, Yan Z.; Zhizhin, Konstantin Yu.; Kuznetsov, Nikolai T.; Elskaya, Anna V.

    2016-01-01

    An interaction of the boron clusters closo-borates K 2 [B 10 H 10 ], K 2 [B 12 H 12 ] and their functionalized derivatives with serum proteins human (HSA) and bovine (BSA) albumins and immonoglobulin IgG as well as globular proteins β-lactoglobulin and lysozyme was characterized. The steady state and time resolved protein fluorescence quenching studies point on the binding of the closo-borate arylamine derivatives to serum albumins and discrimination of other proteins. The mechanism of the albumin fluorescence quenching by the closo-borate arylamine derivatives was proposed. The complex formation between albumin and the closo-borate molecules has been confirmed by isothermal titration calorimetry (ITC). The compound (K 2 [B 10 H 10 ]) and its arylamine derivative both interact with HSA, have close values of K a (1.4 and 1.2×10 3 M −1 respectively) and Gibbs energy (−17.9 and −17.5 kJ/mol respectively). However, the arylamine derivative forms complex with the higher guest/host binding ratio (4:1) comparing to the parent closo-borate (2:1). - Highlights: • Complex formation between boron clusters closo-borates and albumins was confirmed. • Functional substituent of closo-borate strongly affects its complex with albumins. • Binding of arylamine closo-borates essentially quench the albumin fluorescence. • Mechanism of tryptophan emission quenching by arylamine closo-borates was proposed.

  15. Microcalorimetric and potentiometric titration studies on the adsorption of copper by P. putida and B. thuringiensis and their composites with minerals

    Energy Technology Data Exchange (ETDEWEB)

    Fang Linchuan [State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070 (China); Key Laboratory of Subtropical Agriculture and Environment, Ministry of Agriculture, College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070 (China); Cai Peng; Li Pengxiang; Wu Huayong; Liang Wei; Rong Xingmin [Key Laboratory of Subtropical Agriculture and Environment, Ministry of Agriculture, College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070 (China); Chen Wenli [State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070 (China); Huang Qiaoyun, E-mail: qyhuang@mail.hzau.edu.cn [State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070 (China); Key Laboratory of Subtropical Agriculture and Environment, Ministry of Agriculture, College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070 (China)

    2010-09-15

    In order to have a better understanding of the interactions of heavy metals with bacteria and minerals in soil and associated environments, isothermal titration calorimetry (ITC), potentiometric titration and equilibrium sorption experiments were conducted to investigate the adsorption behavior of Cu(II) by Bacillus thuringiensis, Pseudomonas putida and their composites with minerals. The interaction of montmorillonite with bacteria increased the reactive sites and resulted in greater adsorption for Cu(II) on their composites, while decreased adsorption sites and capacities for Cu(II) were observed on goethite-bacteria composites. A gram-positive bacterium B. thuringiensis played a more important role than a gram-negative bacterium P. putida in determining the properties of the bacteria-minerals interfaces. The enthalpy changes ({Delta}H{sub ads}) from endothermic (6.14 kJ mol{sup -1}) to slightly exothermic (-0.78 kJ mol{sup -1}) suggested that Cu(II) is complexed with the anionic oxygen ligands on the surface of bacteria-mineral composites. Large entropies (32.96-58.89 J mol{sup -1} K{sup -1}) of Cu(II) adsorption onto bacteria-mineral composites demonstrated the formation of inner-sphere complexes in the presence of bacteria. The thermodynamic data implied that Cu(II) mainly bound to the carboxyl and phosphoryl groups as inner-sphere complexes on bacteria and mineral-bacteria composites.

  16. Microcalorimetric and potentiometric titration studies on the adsorption of copper by P. putida and B. thuringiensis and their composites with minerals.

    Science.gov (United States)

    Fang, Linchuan; Cai, Peng; Li, Pengxiang; Wu, Huayong; Liang, Wei; Rong, Xingmin; Chen, Wenli; Huang, Qiaoyun

    2010-09-15

    In order to have a better understanding of the interactions of heavy metals with bacteria and minerals in soil and associated environments, isothermal titration calorimetry (ITC), potentiometric titration and equilibrium sorption experiments were conducted to investigate the adsorption behavior of Cu(II) by Bacillus thuringiensis, Pseudomonas putida and their composites with minerals. The interaction of montmorillonite with bacteria increased the reactive sites and resulted in greater adsorption for Cu(II) on their composites, while decreased adsorption sites and capacities for Cu(II) were observed on goethite-bacteria composites. A gram-positive bacterium B. thuringiensis played a more important role than a gram-negative bacterium P. putida in determining the properties of the bacteria-minerals interfaces. The enthalpy changes (DeltaH(ads)) from endothermic (6.14 kJ mol(-1)) to slightly exothermic (-0.78 kJ mol(-1)) suggested that Cu(II) is complexed with the anionic oxygen ligands on the surface of bacteria-mineral composites. Large entropies (32.96-58.89 J mol(-1) K(-1)) of Cu(II) adsorption onto bacteria-mineral composites demonstrated the formation of inner-sphere complexes in the presence of bacteria. The thermodynamic data implied that Cu(II) mainly bound to the carboxyl and phosphoryl groups as inner-sphere complexes on bacteria and mineral-bacteria composites. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Radiation damage study for silicon calorimetry: Summary of first year's activity

    International Nuclear Information System (INIS)

    Russ, J.S.

    1988-01-01

    In the first contract year of this activity at Carnegie-Mellon we have had two major objectives. These were to devise and test a non-intrusive means to measure the energy and spatial profiles of the neutrons generated in a hadronic cascade at high energy; and to study the calibration systematics of silicon diode detectors as a prelude to their evaluation for SSC calorimetry. These objectives have been carried out, as are described in this paper. In addition we have recoded the ORNL detector simulation program HETC to operate on a VAX and are working on the conversion of the low energy neutron transport program MORSE. These programs are used heavily at Oak Ridge (Gabriel and coworkers) for cascade studies. For silicon calorimetry one wants to have more control over the energy deposition routines, especially in MORSE. Unfortunately, MORSE is heavily-laden with machine code, and its conversion is going slowly. 11 refs., 5 figs

  18. Scintillator plate calorimetry

    International Nuclear Information System (INIS)

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin

  19. Calorimetry

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    We have divided this study of calorimetry at the SLC into five topics: physics with calorimeters, readout geometries, performance of existing detectors, calorimeter technologies, and new calorimeter designs. The first topic is a review of the Z 0 physics in which calorimetry would be important. We discuss the Monte Carlo model and the general features of the events which it generates. We consider how the physics affects the design of the electromagnetic and hadron calorimeters in energy resolution, segmentation, solid angle coverage, and general performance. The two ways of reading out a calorimeter, strips and towers, are the basis of the second topic. We discuss a model which makes quantitative comparisons of these two schemes, with particular reference to electromagnetic calorimeters. These programs should be useful in other studies of calorimeter performance as well. There are six detectors at PEP and SPEAR with calorimetric elements. The third topic is a review of their performance at present energies and an evaluation of the problems which would arise at SLC energies. The new technologies which may be mature enough for use in an SLC detector are considered as the fourth topic. Some are now being built into anti pp detectors, others are in test beam stages, and others are still bright ideas. We review ten techniques and include references for further pursuit. The last section combines the physics goals, readout schemes, and present and future techniques into sensible calorimeter designs which sharpen the issues. Six models resulted. We discuss their strengths, weaknesses, feasibility, and rough costs

  20. Automated uranium titration system

    International Nuclear Information System (INIS)

    Takahashi, M.; Kato, Y.

    1983-01-01

    An automated titration system based on the Davies-Gray method has been developed for accurate determination of uranium. The system consists of a potentiometric titrator with precise burettes, a sample changer, an electronic balance and a desk-top computer with a printer. Fifty-five titration vessels are loaded in the sample changer. The first three contain the standard solution for standardizing potassium dichromate titrant, and the next two and the last two contain the control samples for data quality assurance. The other forty-eight measurements are carried out for sixteen unknown samples. Sample solution containing about 100 mg uranium is taken in a titration vessel. At the pretreatment position, uranium (VI) is reduced to uranium (IV) by iron (II). After the valency adjustment, the vessel is transferred to the titration position. The rate of titrant addition is automatically controlled to be slower near the end-point. The last figure (0.01 mL) of the equivalent titrant volume for uranium is calculated from the potential change. The results obtained with this system on 100 mg uranium gave a precision of 0.2% (RSD,n=3) and an accuracy of better than 0.1%. Fifty-five titrations are accomplished in 10 hours. (author)

  1. Electrophoretic separation of alginic sodium diester and sodium hexametaphosphate in chondroitin sulfate that interfere with the cetylpyridinium chloride titration assay.

    Science.gov (United States)

    Weiguo, Zhang; Giancaspro, Gabriel; Adams, Kristie M; Neal-Kababick, James; Hildreth, Jana; Li, Aishan; Roman, Mark C; Betz, Joseph M

    2014-01-01

    The most commonly used chondroitin sulfate (CS) assay method is cetylpyridinium chloride (CPC) titration. Cellulose acetate membrane electrophoresis (CAME) is the technique used for detection of impurities in the U.S. Pharmacopeia's CS monograph. Because CPC titration is a relatively nonspecific quantitative technique, the apparent amount of CS as determined by CPC titration alone may not reflect the true amount of CS due to possible interference with the CPC assay by impurities that contain CPC titratable functional groups. When CAME is used in conjunction with CPC titration, certain non-CS and adulterants can be visualized and estimated, and a true value for CS can be assigned once the presence of these non-CS impurities has been ruled out. This study examines conjunct application of CPC and CAME in ascertaining CS assay and purity in the presence of certain adulterants. These include propylene glycol alginate sulfate sodium, known in commerce as alginic sodium diester (ASD), and Zero One (Z1), a water-soluble agent newly reported in the CS marketplace and subsequently identified as sodium hexametaphosphate. ASD, Z1, and CS are similar in physical appearance and solubility in water and ethanol. They are also titratable anions and form ionic pairs with CPC, therefore interfering with the CPC titration assay for CS CAME separates these adulterants from each other and from CS by differences in their electrophoretic mobility. CAME is able to detect these impurities in CS at levels as low as 0.66% by weight. Although it is recommended that a method for detecting impurities (e.g., CAME) be used in cormbination with relatively nonspecific assay methods such as CPC titration, this is seldom done in practice. Assay results for CS derived fromn CPC titration may, therefore, be misleading, leaving the CS supply chain vulnerable to adulteration. In this study, the authors investigated ASD and Z1 adulteration of CS and developed an electrophoretic separation of these

  2. An interaction of the functionalized closo-borates with albumins: The protein fluorescence quenching and calorimetry study

    Energy Technology Data Exchange (ETDEWEB)

    Losytskyy, Mykhaylo Yu., E-mail: mlosytskyy@gmail.com [Institute of Molecular Biology and Genetics, NASU, 150 Zabolotnogo Street, 03143 Kyiv (Ukraine); Kovalska, Vladyslava B. [Institute of Molecular Biology and Genetics, NASU, 150 Zabolotnogo Street, 03143 Kyiv (Ukraine); Varzatskii, Oleg A. [V. I. Vernadsky Institute of General and Inorganic Chemistry, 32/34 Palladin Avenue, 03080 Kyiv (Ukraine); Kuperman, Marina V. [Institute of Molecular Biology and Genetics, NASU, 150 Zabolotnogo Street, 03143 Kyiv (Ukraine); Potocki, Slawomir; Gumienna-Kontecka, Elzbieta [Faculty of Chemistry, Wroclaw University, 14F. Joliot-Curie Street, 50-383 Wroclaw (Poland); Zhdanov, Andrey P. [Kurnakov Institute of General and Inorganic Chemistry, 31 Leninskii Avenue, 119991 Moscow (Russian Federation); Yarmoluk, Sergiy M. [Institute of Molecular Biology and Genetics, NASU, 150 Zabolotnogo Street, 03143 Kyiv (Ukraine); Voloshin, Yan Z. [Nesmeyanov Institute of Organoelement Compounds, 28 Vavilova Street, 119991 Moscow (Russian Federation); Zhizhin, Konstantin Yu.; Kuznetsov, Nikolai T. [Kurnakov Institute of General and Inorganic Chemistry, 31 Leninskii Avenue, 119991 Moscow (Russian Federation); Elskaya, Anna V. [Institute of Molecular Biology and Genetics, NASU, 150 Zabolotnogo Street, 03143 Kyiv (Ukraine)

    2016-01-15

    An interaction of the boron clusters closo-borates K{sub 2}[B{sub 10}H{sub 10}], K{sub 2}[B{sub 12}H{sub 12}] and their functionalized derivatives with serum proteins human (HSA) and bovine (BSA) albumins and immonoglobulin IgG as well as globular proteins β-lactoglobulin and lysozyme was characterized. The steady state and time resolved protein fluorescence quenching studies point on the binding of the closo-borate arylamine derivatives to serum albumins and discrimination of other proteins. The mechanism of the albumin fluorescence quenching by the closo-borate arylamine derivatives was proposed. The complex formation between albumin and the closo-borate molecules has been confirmed by isothermal titration calorimetry (ITC). The compound (K{sub 2}[B{sub 10}H{sub 10}]) and its arylamine derivative both interact with HSA, have close values of K{sub a} (1.4 and 1.2×10{sup 3} M{sup −1} respectively) and Gibbs energy (−17.9 and −17.5 kJ/mol respectively). However, the arylamine derivative forms complex with the higher guest/host binding ratio (4:1) comparing to the parent closo-borate (2:1). - Highlights: • Complex formation between boron clusters closo-borates and albumins was confirmed. • Functional substituent of closo-borate strongly affects its complex with albumins. • Binding of arylamine closo-borates essentially quench the albumin fluorescence. • Mechanism of tryptophan emission quenching by arylamine closo-borates was proposed.

  3. A calorimetric study of solute effects on the kinetic stability of a-amylase

    DEFF Research Database (Denmark)

    Olsen, Søren Nymand; Andersen, Kim Bruno; Øgendal, Lars Holm

    2009-01-01

    In this study we evaluated the applications of isothermal titration calorimetry (ITC) to Study solute effects on the kinetics of irreversible protein denaturation. More specifically, denaturation of Bacillus Halmapalus alpha-amylase (BHA) was initiated by addition of EDTA to the calorimetric cell...

  4. Thermodynamics of binding interactions between extracellular polymeric substances and heavy metals by isothermal titration microcalorimetry.

    Science.gov (United States)

    Yan, Peng; Xia, Jia-Shuai; Chen, You-Peng; Liu, Zhi-Ping; Guo, Jin-Song; Shen, Yu; Zhang, Cheng-Cheng; Wang, Jing

    2017-05-01

    Extracellular polymeric substances (EPS) play a crucial role in heavy metal bio-adsorption using activated sludge, but the interaction mechanism between heavy metals and EPS remains unclear. Isothermal titration calorimetry was employed to illuminate the mechanism in this study. The results indicate that binding between heavy metals and EPS is spontaneous and driven mainly by enthalpy change. Extracellular proteins in EPS are major participants in the binding process. Environmental conditions have significant impact on the adsorption performance. Divalent and trivalent cations severely impeded the binding of heavy metal ions to EPS. Electrostatic interaction mainly attributed to competition between divalent cations and heavy metal ions; trivalent cations directly competed with heavy metal ions for EPS binding sites. Trivalent cations were more competitive than divalent cations for heavy metal ion binding because they formed complexing bonds. This study facilitates a better understanding about the interaction between heavy metals and EPS in wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Calorimetry

    International Nuclear Information System (INIS)

    McDonald, J.C.

    1978-01-01

    The techniques and equipment currently employed for calorimetric dosimetry have been briefly surveyed and the status of some recent measurements presented. The problems which remain to be investigated are: the thermal defect, the suitability of A-150 plastic as a material for heavy charged particle calorimetry and calorimeter designs that are appropriate for specific radiation situations, including cryogenic calorimeters

  6. Up-titration of allopurinol in patients with gout.

    Science.gov (United States)

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Titration Curves: Fact and Fiction.

    Science.gov (United States)

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  8. Study of complex amalgams containing alkali metals by method of broken thermometric titration

    International Nuclear Information System (INIS)

    Filippova, L.M.; Zebreva, A.I.; Espenbetov, A.A.

    1977-01-01

    Complex potassium-cadmium and sodium-cadmium amalgams containing different amounts of the alkali metal nad cadmium have been studied by thermometric titration with mercury. The experiments have been carried out in argon atmosphere at 25 deg C. As evidenced by the titration of sodium-cadmium amalgams, in the range of concentrations studied (Csub(Na)=0.71-2.95, Csub(Cd)=4.38-6.45 g-at/lHg) no solid phase is formed in them. Potassium-cadmium amalgams where the metals content is no higher than their individual solubility in mercury, display, when being mercury-titrated, negative heat effects due to solid phase formation. An estimation is made of the solid phase composition, its solubility in mercury and the heat of dissolution. The solid phase appearing in complex K-Cd amalgams is likely to contain K and Cd in a ratio 1:1 its conventional solubility product is 5.4 g-at/l Hg, and the heat of dissolution in mercury at 25 deg is -21 +-4 kJ/g-at

  9. Potentiometric titration of plutonium

    International Nuclear Information System (INIS)

    Silver, G.L.

    1978-01-01

    In the potentiometric titration of plutonium(III), it has been customary to take the equivalence point as the inflection point on a plot of potential vs. volume of titrant. It have not been, however, demonstrated, that the stoichiometric end point corresponds to the inflection point. Suggestions are made according to which these points may not correspond in the potentiometric titration of plutonium(III), as these titrations are ordinarily concluded in a period of time which is short compared to the time required for valence state rearrangement through disproportionation. (T.G.)

  10. Calorimetry and thermal methods in catalysis

    CERN Document Server

    Auroux, Aline

    2013-01-01

    The book is about calorimetry and thermal analysis methods, alone or linked to other techniques, as applied to the characterization of catalysts, supports and adsorbents, and to the study of catalytic reactions in various domains: air and wastewater treatment, clean and renewable energies, refining of hydrocarbons, green chemistry, hydrogen production and storage. The book is intended to fill the gap between the basic thermodynamic and kinetics concepts acquired by students during their academic formation, and the use of experimental techniques such as thermal analysis and calorimetry to answ

  11. Potentiometric titration with polarized electrodes

    International Nuclear Information System (INIS)

    Chikryzova, E.G.

    1977-01-01

    Based on the analysis of the works carried out during 1911-75 consideration is given to the present state of the method of potentiometric titration with polarized electrodes. The material is generalized in the tabular form indicating the elments of interest, titration conditions and the objects to be analyzed. The list and classification of the potentiometric titration methods intended for determining organic and inorganic substances are presented

  12. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    Science.gov (United States)

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. End-point construction and systematic titration error in linear titration curves-complexation reactions

    NARCIS (Netherlands)

    Coenegracht, P.M.J.; Duisenberg, A.J.M.

    The systematic titration error which is introduced by the intersection of tangents to hyperbolic titration curves is discussed. The effects of the apparent (conditional) formation constant, of the concentration of the unknown component and of the ranges used for the end-point construction are

  14. The formation of amino acid and dipeptide complexes with α-cyclodextrin and cucurbit[6]uril in aqueous solutions studied by titration calorimetry

    International Nuclear Information System (INIS)

    Buschmann, H.-J.; Schollmeyer, E.; Mutihac, L.

    2003-01-01

    The complex stabilities and the thermodynamic data for the complexation of α-cyclodextrin and cucurbit[6]uril with some amino acids (glycine, L-alanine, L-valine, L-phenylalanine, 6-amino hexanoic acid, 8-amino octanoic acid, 11-amino undecanoic acid) and dipeptides (glycyl-glycine, glycyl-L-valine, glycyl-L-leucine and glycyl-L-phenylalanine) have been determined in aqueous solution by calorimetric titrations. The complex formation with α-cyclodextrin is mainly favoured by entropic contributions due to the release of water molecules from the cavity of the ligand. The values of the reaction enthalpies are small with the exception of 11-amino undecanoic acid. In case of the ligand cucurbit[6]uril, ion-dipole interactions between the protonated amino groups of the amino acids and the carbonyl groups take place. By steric reasons these interactions are lowered for native amino acids because the polar carboxylic groups are always located outside the hydrophobic cavity of cucurbit[6]uril. The complexes of both ligands with dipeptides in water are characterised by hydrophobic interactions and in case of cucurbit[6]uril by additional ion-dipole interactions

  15. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    Science.gov (United States)

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  16. Evaluation of an automatic uranium titration system

    International Nuclear Information System (INIS)

    Lewis, K.

    1980-01-01

    The titration system utilizes the constant current coulometric titration of Goldbeck and Lerner. U(VI) is reduced to U(IV) by Fe(II). V(V) is generated to titrate the U(IV), and the titration is followed potentiometrically. The evaluation shows that the recovery of uranium is 100% at the 40-mg level. The accuracy is generally +-0.10% or better. The smallest sample weight at which reliable results were obtained was 40 mg of uranium. Time for one analysis is 15 minutes. Advantages and disadvantages of the automated titrator are listed

  17. Automatic titrator for high precision plutonium assay

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hollen, R.M.

    1986-01-01

    Highly precise assay of plutonium metal is required for accountability measurements. We have developed an automatic titrator for this determination which eliminates analyst bias and requires much less analyst time. The analyst is only required to enter sample data and start the titration. The automated instrument titrates the sample, locates the end point, and outputs the results as a paper tape printout. Precision of the titration is less than 0.03% relative standard deviation for a single determination at the 250-mg plutonium level. The titration time is less than 5 min

  18. Determination of the thermodynamic properties of complexation and extraction by micro-calorimetry

    International Nuclear Information System (INIS)

    Charbonnel, M.Ch.; Flandin, J.L.

    2000-01-01

    The CEA is currently developing the DIAMEX process, the first step in the strategy for the separation of minor actinides from high-level radioactive waste. The extractant belongs to the diamide family of molecules and is able to co-extract trivalent actinides and lanthanides. This study focuses on the thermodynamic properties (ΔH, ΔG, ΔS) of lanthanide extraction by malonamide in order to better understand the mechanisms involved and to account for differences in the behavior of various diamide extractants. The main technique used is microcalorimetric titration. The Thermal Activity Monitor (TAM) microcalorimeter is a modular system with a highly stable (± 0.1 mK) temperature-controlled bath containing up to four calorimetry vessel units. The sensor bulbs inserted in the reaction vessel can measure heat flows in static or dynamic conditions. Micro-calorimetry, and calorimetric titration in particular, is a fast growing field due to technical improvements in both hardware and software. In the case of an equilibrium reaction, titration allows both Δ r G and Δ r H (and thus Δ r S) to be determined simultaneously. It was decided to initiate this thermochemical investigation with a homogeneous phase reaction, and the first study concerned the aqueous phase complexation of a trivalent lanthanide ion by a water-soluble diamide, tetraethyl-malonamide (TEMA: (C 2 H 5 ) 2 NCO-CH 2 CON(C 2 H 5 ) 2 ). In the test system, the heat of dilution of the diamide in water is preponderant over the heat arising from the complexation reaction; the result is a positive value corresponding to an endothermic reaction. However, the equilibration constant K and Δ H are both very small, and cannot be calculated from the resulting Q v f(n TEMA ) curves. Moreover, in aqueous phase, the reactions involved are different from those observed when neodymium(III) is extracted into an organic phase, and the medium must be further characterized before the calorimetry data can be fully

  19. Isothermal titration calorimetric and computational studies on the binding of chitooligosaccharides to pumpkin (Cucurbita maxima) phloem exudate lectin.

    Science.gov (United States)

    Narahari, Akkaladevi; Singla, Hitesh; Nareddy, Pavan Kumar; Bulusu, Gopalakrishnan; Surolia, Avadhesha; Swamy, Musti J

    2011-04-14

    The interaction of chitooligosaccharides [(GlcNAc)(2-6)] with pumpkin phloem exudate lectin (PPL) was investigated by isothermal titration calorimetry and computational methods. The dimeric PPL binds to (GlcNAc)(3-5) with binding constants of 1.26-1.53 × 10(5) M(-1) at 25 °C, whereas chitobiose exhibits approximately 66-fold lower affinity. Interestingly, chitohexaose shows nearly 40-fold higher affinity than chitopentaose with a binding constant of 6.16 × 10(6) M(-1). The binding stoichiometry decreases with an increase in the oligosaccharide size from 2.26 for chitobiose to 1.08 for chitohexaose. The binding reaction was essentially enthalpy driven with negative entropic contribution, suggesting that hydrogen bonds and van der Waals' interactions are the main factors that stabilize PPL-saccharide association. The three-dimensional structure of PPL was predicted by homology modeling, and binding of chitooligosaccharides was investigated by molecular docking and molecular dynamics simulations, which showed that the protein binding pocket can accommodate up to three GlcNAc residues, whereas additional residues in chitotetraose and chitopentaose did not exhibit any interactions with the binding pocket. Docking studies with chitohexaose indicated that the two triose units of the molecule could interact with different protein binding sites, suggesting formation of higher order complexes by the higher oligomers of GlcNAc by their simultaneous interaction with two protein molecules.

  20. Risks and Benefits of Rapid Clozapine Titration.

    Science.gov (United States)

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  1. Risks and benefits of rapid clozapine titration

    Directory of Open Access Journals (Sweden)

    Jeannie D. Lochhead

    2016-05-01

    Full Text Available Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  2. Automated back titration method to measure phosphate

    International Nuclear Information System (INIS)

    Comer, J.; Tehrani, M.; Avdeef, A.; Ross, J. Jr.

    1987-01-01

    Phosphate was measured in soda drinks and as an additive in flour, by a back titration method in which phosphate was precipitated with lanthanum, and the excess lanthanum was titrated with fluoride. All measurements were performed using the Orion fluoride electrode and the Orion 960 Autochemistry System. In most commercial automatic titrators, the inflection point of the titration curve, calculated from the first derivative of the curve, is used to find the equivalence polar of the titration. The inflection technique is compared with a technique based on Gran functions, which uses data collected after the end point and predicts the equivalence point accordingly

  3. Potentiometric titrations in anhydrous acetic acid

    International Nuclear Information System (INIS)

    Le Port, L.

    1966-03-01

    The method used for studying anhydrous acetic acid is potentiometry with a glass electrode. We have in this way studied the titration of common inorganic acids (HClO 4 - HBr - H 2 SO 4 - HCl - HNO 3 - H 3 PO 4 ) and of some metallic salts. Furthermore we have shown that complex acids are formed between HCl and some metallic chlorides. An analysis of the titration curves for the inorganic acids against pyridinium chloride has made it possible to calculate a certain number of values for the dissociation pK of these acids and of the corresponding pyridinium salts. The titration of metallic perchlorates constitutes a method of studying the stability of acetates; we have thus been able to draw up a classification for some of these acetates. The metallic chlorides studied fall into two groups according to their behaviour in weak or strong acids. The differences have been explained on the basis of the role played by solvolysis. In the third part we have studied the acidic properties of mixtures of HCl with certain metallic chlorides. This work has demonstrated the existence, in certain cases, of acid complexes of the type (HCl) m MCl n . (author) [fr

  4. Coulometric titration of niobium in EDTA complexing solution

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1976-01-01

    Constant current coulometry of Nb in EDTA was studied employing both potentiometric and amperometric end-point techniques. The titrations were based on the oxidation of Nb(IV)-EDTA with electrogenerated Fe(III) at a graphite anode. The rate of disproportionation of Nb(IV)-EDTA was found to be slow enough not to effect the accuracy sought for the titration. The coulometric titration of Nb in EDTA was found to be more accurate than in 1F sulfuric acid. The mean error in the titrations of 4.76 to 19.65 of Nb in a volume of about 100 ml of 0.02 to 0.04F EDTA was 0.13%. It was found that Ta may be tolerated to a ratio of 1:4, Ta:Nb, in a solution containing 13 mg of Nb. (author)

  5. Chemical kinetics on thermal decompositions of cumene hydroperoxide in cumene studied by calorimetry: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Duh, Yih-Shing, E-mail: yihshingduh@yahoo.com.tw [Department of Occupation Safety and Health, Jen-Teh Junior College of Medicine, Nursing and Management, Miaoli, 35664, Taiwan, ROC (China); Department of Safety, Health and Environmental Engineering, National United University, No. 1 Lien-Da, Miaoli, 36052, Taiwan, ROC (China)

    2016-08-10

    Highlights: • Chemical kinetics on thermal decompositions of CHP are conducted and summarized. • Kinetics agrees well between data from DSC and adiabatic calorimetry. • Ea is determined to be about 120 kJ mol{sup −1} by various calorimetry. • LogA (A in s{sup −1}) is determined to be about 11.8 by various calorimetry. - Abstract: Study on chemical kinetics related to the thermal decomposition of cumene hydoperoxide (CHP) in cumene is summarized in this work. It is of great importance to gather and compare the differences between these kinetic parameters for further substantial applications in the chemical industry and process safety. CHP has been verified to possess an autocatalytic behavior by using microcalorimetry (such as TAM and C-80) operated at isothermal mode in the temperature range from 70 °C to 120 °C. However, it exhibits a reaction of n-th order detected by non-isothermal DSC scanning and adiabatic calorimeter. By the isothermal aging tests, activation energy and frequency factor in logA(s{sup −1}) were averaged to be (117.3 ± 5.9) kJ mol{sup −1}and (11.4 ± 0.3), respectively. Kinetic parameters acquired from data of interlaboratories by using heat-flow calorimetry, the averaged activation energy and frequency factor in logA(s{sup −1}) were (119.3 ± 11.3) kJ mol{sup −1}and (12.0 ± 0.2), respectively. On the analogy of results from adiabatic calorimetry, the activation energy and frequency factor in logA(s{sup −1}) were respectively averaged to be (122.4 ± 9.2) kJ mol{sup −1}and (11.8 ± 0.8). Five sets of kinetic models in relation to autocatalytic reactions are collected and discussed as well.

  6. Review of MEMS differential scanning calorimetry for biomolecular study

    Science.gov (United States)

    Yu, Shifeng; Wang, Shuyu; Lu, Ming; Zuo, Lei

    2017-12-01

    Differential scanning calorimetry (DSC) is one of the few techniques that allow direct determination of enthalpy values for binding reactions and conformational transitions in biomolecules. It provides the thermodynamics information of the biomolecules which consists of Gibbs free energy, enthalpy and entropy in a straightforward manner that enables deep understanding of the structure function relationship in biomolecules such as the folding/unfolding of protein and DNA, and ligand bindings. This review provides an up to date overview of the applications of DSC in biomolecular study such as the bovine serum albumin denaturation study, the relationship between the melting point of lysozyme and the scanning rate. We also introduce the recent advances of the development of micro-electro-mechanic-system (MEMS) based DSCs.

  7. Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group.

    Science.gov (United States)

    Oshima, Taku; Berger, Mette M; De Waele, Elisabeth; Guttormsen, Anne Berit; Heidegger, Claudia-Paula; Hiesmayr, Michael; Singer, Pierre; Wernerman, Jan; Pichard, Claude

    2017-06-01

    This review aims to clarify the use of indirect calorimetry (IC) in nutritional therapy for critically ill and other patient populations. It features a comprehensive overview of the technical concepts, the practical application and current developments of IC. Pubmed-referenced publications were analyzed to generate an overview about the basic knowledge of IC, to describe advantages and disadvantages of the current technology, to clarify technical issues and provide pragmatic solutions for clinical practice and metabolic research. The International Multicentric Study Group for Indirect Calorimetry (ICALIC) has generated this position paper. IC can be performed in in- and out-patients, including those in the intensive care unit, to measure energy expenditure (EE). Optimal nutritional therapy, defined as energy prescription based on measured EE by IC has been associated with better clinical outcome. Equations based on simple anthropometric measurements to predict EE are inaccurate when applied to individual patients. An ongoing international academic initiative to develop a new indirect calorimeter aims at providing innovative and affordable technical solutions for many of the current limitations of IC. Indirect calorimetry is a tool of paramount importance, necessary to optimize the nutrition therapy of patients with various pathologies and conditions. Recent technical developments allow broader use of IC for in- and out-patients. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  8. Coulometric titration at low temperatures-nonstoichiometric silver selenide

    OpenAIRE

    Beck, Gesa K.; Janek, Jürgen

    2003-01-01

    A modified coulometric titration technique is described for the investigation of nonstoichiometric phases at low temperatures. It allows to obtain titration curves at temperatures where the conventional coulometric titration technique fails because of too small chemical diffusion coefficients of the mobile component. This method for indirect coulometric titration is applied to silver selenide between -100 and 100 °C. The titration curves are analyzed on the basis of a defect chemical model an...

  9. Study of gamma irradiated polyethylenes by temperature modulated differential scanning calorimetry

    International Nuclear Information System (INIS)

    Secerov, B.; Galovic, S.; Trifunovic, S.; Milicevic, D.; Suljovrujic, E.

    2011-01-01

    Complete text of publication follows. The various polyethylenes (PEs) and effects of high energy radiation on theirs structures were widely studied in the past using conventional Differential Scanning Calorimetry (DSC) measurements. In this work, we applied the Temperature Modulated Differential Scanning Calorimetry (TMDSC) technique in order to obtain more information about the influence of initial structural differences and gamma radiation on the evolution in structure and thermal properties of different polyethylenes. For this reason, low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) samples were exposed to gamma radiation, in air, to a wide range of absorbed doses (up to 2400 kGy). The separation of the total heat flow TMDSC signal into a reversing and nonreversing part enabled to observed the low temperature enthalpy relaxation (related to the existence of the 'rigid amorphous phase') and recrystallization processes as well as to follow their and/or radiation-induced evolution of melting in a more revealing manner compared to the case of the conventional DSC. Consequently, our results indicate that TMDSC could improve the understanding of radiation-induced effects in polymers.

  10. Potentiometric titration of metal ions in ethanol.

    Science.gov (United States)

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  11. Improving medication titration in heart failure by embedding a structured medication titration plan.

    Science.gov (United States)

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (pplan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Dose Titration of Pregabalin in Patients with Painful Diabetic Peripheral Neuropathy: Simulation Based on Observational Study Patients Enriched with Data from Randomized Studies.

    Science.gov (United States)

    Alexander, Joe; Edwards, Roger A; Manca, Luigi; Grugni, Roberto; Bonfanti, Gianluca; Emir, Birol; Whalen, Edward; Watt, Stephen; Parsons, Bruce

    2018-03-01

    Achieving a therapeutic response to pregabalin in patients with painful diabetic peripheral neuropathy (pDPN) requires adequate upward dose titration. Our goal was to identify relationships between titration and response to pregabalin in patients with pDPN. Data were integrated from nine randomized, placebo-controlled clinical trials as well as one 6-week open-label observational study conducted by 5808 physicians (2642 patients with pDPN) in standard outpatient settings in Germany. These studies evaluated pregabalin for treatment of pDPN. Using these data, we examined "what if" scenarios using a microsimulation platform that integrates data from randomized and observational sources as well as autoregressive-moving-average with exogenous inputs models that predict pain outcomes, taking into account weekly changes in pain, sleep interference, dose, and other patient characteristics that were unchanging. Final pain levels were significantly different depending on dose changes (P titration regardless of baseline pain severity. Altogether, 78.5% of patients with pDPN had 0-1 dose change, and 15.2% had ≥ 2 dose changes. Simulation demonstrated that the 4.8% of inadequately titrated patients who did not improve/very much improve their pain levels would have benefited from ≥ 2 dose changes. Patient satisfaction with tolerability (range 90.3-96.2%) was similar, regardless of baseline pain severity, number of titrations, or extent of improvement, suggesting that tolerability did not influence treatment response patterns. Upward dose titration reduced pain in patients with pDPN who actually received it. Simulation also predicted pain reduction in an inadequately titrated nonresponder subgroup of patients had they actually received adequate titration. The decision not to uptitrate must have been driven by factors other than tolerability. Pfizer, Inc.

  13. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    Science.gov (United States)

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  14. Theory of calorimetry

    CERN Document Server

    Zielenkiewicz, Wojciech

    2004-01-01

    The purpose of this book is to give a comprehensive description of the theoretical fundamentals of calorimetry. The considerations are based on the relations deduced from the laws and general equations of heat exchange theory and steering theory.

  15. Calorimetry end-point predictions

    International Nuclear Information System (INIS)

    Fox, M.A.

    1981-01-01

    This paper describes a portion of the work presently in progress at Rocky Flats in the field of calorimetry. In particular, calorimetry end-point predictions are outlined. The problems associated with end-point predictions and the progress made in overcoming these obstacles are discussed. The two major problems, noise and an accurate description of the heat function, are dealt with to obtain the most accurate results. Data are taken from an actual calorimeter and are processed by means of three different noise reduction techniques. The processed data are then utilized by one to four algorithms, depending on the accuracy desired to determined the end-point

  16. Students' integration of multiple representations in a titration experiment

    Science.gov (United States)

    Kunze, Nicole M.

    A complete understanding of a chemical concept is dependent upon a student's ability to understand the microscopic or particulate nature of the phenomenon and integrate the microscopic, symbolic, and macroscopic representations of the phenomenon. Acid-base chemistry is a general chemistry topic requiring students to understand the topics of chemical reactions, solutions, and equilibrium presented earlier in the course. In this study, twenty-five student volunteers from a second semester general chemistry course completed two interviews. The first interview was completed prior to any classroom instruction on acids and bases. The second interview took place after classroom instruction, a prelab activity consisting of a titration calculation worksheet, a titration computer simulation, or a microscopic level animation of a titration, and two microcomputer-based laboratory (MBL) titration experiments. During the interviews, participants were asked to define and describe acid-base concepts and in the second interview they also drew the microscopic representations of four stages in an acid-base titration. An analysis of the data showed that participants had integrated the three representations of an acid-base titration to varying degrees. While some participants showed complete understanding of acids, bases, titrations, and solution chemistry, other participants showed several alternative conceptions concerning strong acid and base dissociation, the formation of titration products, and the dissociation of soluble salts. Before instruction, participants' definitions of acid, base, and pH were brief and consisted of descriptive terms. After instruction, the definitions were more scientific and reflected the definitions presented during classroom instruction.

  17. A generalized approach for the calculation and automation of potentiometric titrations Part 2. Redox Titrations

    NARCIS (Netherlands)

    Stur, J.; Bos, M.; van der Linden, W.E.

    1984-01-01

    The very fast calculation procedure described earlier is applied to calculate the titration curves of complicated redox systems. The theory is extended slightly to cover inhomogeneous redox systems. Titrations of iodine or 2,6-dichloroindophenol with ascorbic acid are described. It is shown that

  18. An accurate potentiometric titration of 5-25 mg uranium

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Lingerak, W.A.

    1976-01-01

    A potentiometric titration of 5 to 25 mg uranium is described. Sulphamic and phosphoric acid are added to the sample (volume 1 ml), U VI is reduced to U IV by Fe 2+ and the excess of Fe 2+ is oxidized by a mixture of nitric acid, sulphamic acid and ammonium molybdate; vanadyl sulphate is added to ensure a sharp end-point of the titration. The resultant U IV is titrated automatically with 0.02500N potassiumdichromate using a platinum indicator electrode. The automatic titration is performed both with a commercial titrator (Mettler) and with an R.C.N. titrator which waits after each addition until the equilibrium is reached. Using the Mettler titrator an accuracy of 0.05% relative was reached. The R.C.N. setpoint titrator gave results with an accuracy of 0.04% relative at the 20-mg U level. Each titration takes 5 to 7 min. (author)

  19. Oxygen titration after resuscitation from out-of-hospital cardiac arrest: a multi-centre, randomised controlled pilot study (the EXACT pilot trial).

    Science.gov (United States)

    Bray, Janet E; Hein, Cindy; Smith, Karen; Stephenson, Michael; Grantham, Hugh; Finn, Judith; Stub, Dion; Cameron, Peter

    2018-04-20

    Recent studies suggest the administration of 100% oxygen to hyperoxic levels following return-of-spontaneous-circulation (ROSC) post-cardiac arrest may be harmful. However, the feasibility and safety of oxygen titration in the prehospital setting is unknown. We conducted a multi-centre, phase-2 study testing whether prehospital titration of oxygen results in an equivalent number of patients arriving at hospital with oxygen saturations SpO2 ≥ 94%. We enrolled unconscious adults with: sustained ROSC; initial shockable rhythm; an advanced airway; and an SpO2 ≥ 95%. Initially (Sept 2015-March 2016) patients were randomised 1:1 to either 2 litres/minute (L/min) oxygen (titrated) or >10 L/min oxygen (control) via a bag-valve reservoir. However, one site experienced a high number of desaturations (SpO2 titrated arm and this arm was changed (April 2016) to an initial reduction of oxygen to 4 L/min then, if tolerated, to 2 L/min, and the desaturation limit was decreased to titrated (n = 37: 2L/min = 20 and 2-4 L/min = 17) oxygen or control (n = 24). Patients allocated to titrated oxygen were more likely to desaturate compared to controls ((SpO2 titrated: 90% vs. control: 100%) and all patients had a SpO2 ≥ 90%. One patient (control) re-arrested. Survival to hospital discharge was similar. Oxygen titration post-ROSC is feasible in the prehospital environment, but incremental titration commencing at 4L/min oxygen flow may be needed to maintain an oxygen saturation >90% (NCT02499042). Copyright © 2018. Published by Elsevier B.V.

  20. Thermally decarboxylated sodium bicarbonate: Interactions with water vapour, calorimetric study

    Directory of Open Access Journals (Sweden)

    Natalia Volkova

    2013-06-01

    Full Text Available Isothermal titration calorimetry (ITC was used to study interactions between water vapour and the surface of thermally converted sodium bicarbonate (NaHCO3. The decarboxylation degree of the samples was varied from 3% to 35% and the humidity range was 54–100%. The obtained enthalpy values were all exothermic and showed a positive linear correlation with decarboxylation degrees for each humidity studied. The critical humidity, 75% (RHo, was determined as the inflection point on a plot of the mean−ΔHkJ/mole Na2CO3 against RH. Humidities above the critical humidity lead to complete surface dissolution. The water uptake (m was determined after each calorimetric experiment, complementing the enthalpy data. A mechanism of water vapour interaction with decarboxylated samples, including the formation of trona and Wegscheider’s salt on the bicarbonate surface is proposed for humidities below RHo. Keywords: Isothermal titration calorimetry, Sodium bicarbonate, Sodium carbonate, Trona salt, Wegscheider’s salt, Enthalpy, Relative humidity, Pyrolytic decarboxylation

  1. Scintillating-fibre calorimetry

    International Nuclear Information System (INIS)

    Livan, M.; Vercesi, V.; Wigmans, R.

    1995-01-01

    In the past decade, calorimetry based on scintillating plastic fibres as active elements was developed from a conceptual idea to a mature detector technology, which is nowadays widely applied in particle physics experiments. This development and the performance characteristics of representative calorimeters, both for the detection of electromagnetic and hadronic showers, are reviewed. We also discuss new information on shower development processes in dense matter and its application to calorimetric principles that has emerged from some very thorough studies that were performed in the framework of this development. (orig.)

  2. Origin of two time-scale regimes in potentiometric titration of metal oxides. A replica kinetic Monte Carlo study

    International Nuclear Information System (INIS)

    Zarzycki, Piotr P.; Rosso, Kevin M.

    2009-01-01

    Replica Kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface non-uniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation do not necessarily need to be invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic non-uniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.

  3. Origin of two time-scale regimes in potentiometric titration of metal oxides. A replica kinetic Monte Carlo study.

    Science.gov (United States)

    Zarzycki, Piotr; Rosso, Kevin M

    2009-06-16

    Replica kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface nonuniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton-binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation does not necessarily need to be invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic nonuniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed, and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.

  4. Comparison of VFA titration procedures used for monitoring the biogas process.

    Science.gov (United States)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  5. Thermodynamic study of complexation of thorium with pyridine monocarboxylates by calorimetry and DFT calculations

    International Nuclear Information System (INIS)

    Rama Mohana Rao, D.; Rawat, Neetika; Sawant, R.M.; Tomar, B.S.; Manna, D.; Ghanty, T.K.

    2013-01-01

    Stability constants of Th(IV) complexes with pyridine mono-carboxylates, namely, picolinate, nicotinate and isonicotinate have been determined following potentiometric titration of the metal ion and ligand mixtures with NaOH solution of known concentration. These data were used during the analysis of the calorimetric titration data to obtain the enthalpy of complexation reactions. The experimental data have been compared with that obtained from the DFT based theoretical calculations. (author)

  6. Application of calorimetry and thermodynamics to critical problems in materials science

    International Nuclear Information System (INIS)

    Atake, Tooru

    2009-01-01

    Calorimetry and thermodynamic studies have long been playing a very important role in the research fields of fundamental science and technology. Some topics and examples of thermodynamics studies are given, and the details are explained on the basis of the present author's experience, focusing attention to application of adiabatic calorimetry and thermodynamics to solve critical problems in materials science: (1) condensed gas calorimetry and third law entropy, (2) phase transition and polymorphism in simple molecular crystals, (3) incommensurate phase transitions, (4) particle size effects on the phase transitions in ferroelectric/ferroelastic crystals, (5) relaxor ferroelectrics and multi-ferroics, and some other topics in materials science and technology

  7. The CLEO-III Trigger: Calorimetry and tracking

    International Nuclear Information System (INIS)

    Bergfeld, T.J.; Gollin, G.D.; Haney, M.J.

    1996-01-01

    The CLEO-III Trigger provides a trigger decision every 42ns, with a latency of approximately 2.5μs. This paper describes the pipelined signal processing and pattern recognition schemes used by the calorimeter, and the axial and stereo portions of the drift chamber, to provide the information necessary to make these decisions. Field programmable gate arrays are used extensively to provide cluster filtering and location sorting for calorimetry, and path finding for tracking. Analog processing is also employed in the calorimetry to provide additional leverage on the problem. Timing information is extracted from both calorimetry and tracking

  8. Application of prediction of equilibrium to servo-controlled calorimetry measurements

    International Nuclear Information System (INIS)

    Mayer, R.L. II

    1987-01-01

    Research was performed to develop an endpoint prediction algorithm for use with calorimeters operating in the digital servo-controlled mode. The purpose of this work was to reduce calorimetry measurement times while maintaining the high degree of precision and low bias expected from calorimetry measurements. Data from routine operation of two calorimeters were used to test predictive models at each stage of development against time savings, precision, and robustness criteria. The results of the study indicated that calorimetry measurement times can be significantly reduced using this technique. The time savings is, however, dependent on parameters in the digital servo-control algorithm and on packaging characteristics of measured items

  9. Spectroscopic study on variations in illite surface properties after acid-base titration.

    Science.gov (United States)

    Liu, Wen-xin; Coveney, R M; Tang, Hong-xiao

    2003-07-01

    FT-IR, Raman microscopy, XRD, 29Si and 27Al MAS NMR, were used to investigate changes in surface properties of a natural illite sample after acid-base potentiometric titration. The characteristic XRD lines indicated the presence of surface Al-Si complexes, preferable to Al(OH)3 precipitates. In the microscopic Raman spectra, the vibration peaks of Si-O and Al-O bonds diminished as a result of treatment with acid, then increased after hydroxide back titration. The varied ratio of signal intensity between (IV)Al and (VI)Al species in 27Al MAS NMR spectra, together with the stable BET surface area after acidimetric titration, suggested that edge faces and basal planes in the layer structure of illite participated in dissolution of structural components. The combined spectroscopic evidence demonstrated that the reactions between illite surfaces and acid-leaching silicic acid and aluminum ions should be considered in the model description of surface acid-base properties of the aqueous illite.

  10. The Mobile Insulin Titration Intervention (MITI) for Insulin Glargine Titration in an Urban, Low-Income Population: Randomized Controlled Trial Protocol.

    Science.gov (United States)

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-03-13

    Patients on insulin glargine typically visit a clinician to obtain advice on how to adjust their insulin dose. These multiple clinic visits can be costly and time-consuming, particularly for low-income patients. It may be feasible to achieve insulin titration through text messages and phone calls with patients instead of face-to-face clinic visits. The objectives of this study are to (1) evaluate if the Mobile Insulin Titration Intervention (MITI) is clinically effective by helping patients reach their optimal dose of insulin glargine, (2) determine if the intervention is feasible within the setting and population, (3) assess patient satisfaction with the intervention, and (4) measure the costs associated with this intervention. This is a pilot study evaluating an approach to insulin titration using text messages and phone calls among patients with insulin-dependent type 2 diabetes in the outpatient medical clinic of Bellevue Hospital Center, a safety-net hospital in New York City. Patients will be randomized in a 1:1 ratio to either the MITI arm (texting/phone call intervention) or the usual-care arm (in-person clinic visits). Using a Web-based platform, weekday text messages will be sent to patients in the MITI arm, asking them to text back their fasting blood glucose values. In addition to daily reviews for alarm values, a clinician will rereview the texted values weekly, consult our physician-approved titration algorithm, and call the patients with advice on how to adjust their insulin dose. The primary outcome will be whether or not a patient reaches his/her optimal dose of insulin glargine within 12 weeks. Recruitment for this study occurred between June 2013 and December 2014. We are continuing to collect intervention and follow-up data from our patients who are currently enrolled. The results of our data analysis are expected to be available in 2015. This study explores the use of widely-available text messaging and voice technologies for insulin titration

  11. Study on the use of solid electrodes for potentiometric titrations in non-aqueous solvents-I

    International Nuclear Information System (INIS)

    Fatibello Filho, O.; Carvalho, W.M. de; Capelato, M.D.; Bulhoes, L.O.S.; Almeida Neves, E.F. de

    1984-01-01

    Fatty acids and ethanolamines were titrated potentiometrically with tetrabutylammnonium hydroxide in methyl isobutyl ketone-isopropyl alcohol and with perchloric acid in ethanol, respectively. A study of utilization of Sb, Sn, W, PbO 2 , Ti and 316L stainless steel oxides - Ag/AgBr/Bu 4 NBr (x M)/solvent electrode systems have been investigated in comparison with the glass - Ag/AgBr/Bu 4 NBr (x M)/solvent system. The best performance was obtained using W, Sb, PbO 2 and Ti electrodes have yielded a larger potential shift than glass electrode for acid-base titration. (C.L.B.) [pt

  12. Differential scanning calorimetry (DSC) of semicrystalline polymers.

    Science.gov (United States)

    Schick, C

    2009-11-01

    Differential scanning calorimetry (DSC) is an effective analytical tool to characterize the physical properties of a polymer. DSC enables determination of melting, crystallization, and mesomorphic transition temperatures, and the corresponding enthalpy and entropy changes, and characterization of glass transition and other effects that show either changes in heat capacity or a latent heat. Calorimetry takes a special place among other methods. In addition to its simplicity and universality, the energy characteristics (heat capacity C(P) and its integral over temperature T--enthalpy H), measured via calorimetry, have a clear physical meaning even though sometimes interpretation may be difficult. With introduction of differential scanning calorimeters (DSC) in the early 1960s calorimetry became a standard tool in polymer science. The advantage of DSC compared with other calorimetric techniques lies in the broad dynamic range regarding heating and cooling rates, including isothermal and temperature-modulated operation. Today 12 orders of magnitude in scanning rate can be covered by combining different types of DSCs. Rates as low as 1 microK s(-1) are possible and at the other extreme heating and cooling at 1 MK s(-1) and higher is possible. The broad dynamic range is especially of interest for semicrystalline polymers because they are commonly far from equilibrium and phase transitions are strongly time (rate) dependent. Nevertheless, there are still several unsolved problems regarding calorimetry of polymers. I try to address a few of these, for example determination of baseline heat capacity, which is related to the problem of crystallinity determination by DSC, or the occurrence of multiple melting peaks. Possible solutions by using advanced calorimetric techniques, for example fast scanning and high frequency AC (temperature-modulated) calorimetry are discussed.

  13. Non-aqueous titration of hydroxamic acids.

    Science.gov (United States)

    Stamey, T W; Christian, R

    1966-01-01

    Benzohydroxamic acid is titrated with 0.1M tetrabutyl-anunonium hydroxide in nine non-aqueous solvents with three different indicating electrodes. The best results are obtained using dimethylformamide as solvent and platinum-platinum electrodes. Four monoprotic and three diprotic hydroxamie acids and iron(III) benzohydroxamate have been successfully titrated with this system. The effect of quantitative additions of carbon dioxide to the titrant on its apparent molarity are found to be dependent on the amount added, the strength and sample size of acid titrated and the solvent used.

  14. A generalized approach for the calculation and automation of potentiometric titrations Part 1. Acid-Base Titrations

    NARCIS (Netherlands)

    Stur, J.; Bos, M.; van der Linden, W.E.

    1984-01-01

    Fast and accurate calculation procedures for pH and redox potentials are required for optimum control of automatic titrations. The procedure suggested is based on a three-dimensional titration curve V = f(pH, redox potential). All possible interactions between species in the solution, e.g., changes

  15. Studies of factors affecting uranium determinations by automated coulometric titration (New Brunswick Laboratory/Davies--Gray Method)

    International Nuclear Information System (INIS)

    Harrar, J.E.; Boyle, W.G.

    1976-01-01

    The method's errors are defined to ascertain its absolute accuracy. An analytical technique was developed to examine vanadyl sulfate diluent for vanadium (V). None could be found in any of the lots tested. Certain lots of reagent-grade phosphoric acid contained an unidentified impurity that caused high generator-electrode potentials and a positive error. The current-potential characteristics of the generator electrode were measured. The data indicated that a significant fraction of uranium (IV) was oxidized directly during the early stages of titration. Using equations theoretically applicable to such a titration, a negligible difference was found between the inflection point of the titration curve and the equivalence point in the titration. However, the actual experimental curves did not agree with the theoretical curves early in the titration. Measurements of the background current indicated a level equivalent to approximately 0.2 mg uranium. The evaluation of the reagent delivery system used in the automated analyzer revealed adequate reproducibility. 8 tables

  16. Application of prediction of equilibrium to servo-controlled calorimetry measurements

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1987-01-01

    Research was performed to develop an endpoint prediction algorithm for use with calorimeters operating in the digital servo-controlled mode. The purpose of this work was to reduce calorimetry measurement times while maintaining the high degree of precision and low bias expected from calorimetry measurements. Data from routine operation of two calorimeters were used to test predictive models at each stage of development against time savings, precision, and robustness criteria. The results of the study indicated that calorimetry measurement times can be significantly reduced using this technique. The time savings is, however, dependent on parameters in the digital servo-control algorithm and on packaging characteristics of measured items. 7 refs., 4 figs., 1 tab

  17. Carbon dioxide titration method for soil respiration measurements

    OpenAIRE

    Martín Rubio, Luis

    2017-01-01

    This thesis was commissioned by Tampere University of Applied Sciences, which was interested in studying and developing a titration measurement method for soil respiration and biodegradability. Some experiments were carried out measuring soil respiration for testing the method and others adding some biodegradable material like polylactic acid compressed material and 100% biodegradable plastic bags to test its biodegradability and the possibility to measure it via titration. The thesi...

  18. Liquid ionization calorimetry: review and preview

    International Nuclear Information System (INIS)

    Fabjan, C.W.

    1995-01-01

    The experimental requirements at existing and planned accelerators, and new facilities for underground or space-borne experimentation have stimulated a wide-ranging R and D programme in liquid ionization calorimetry. Precision sampling calorimetry is approaching ''crystal'' energy resolution whilst their rate capabilities will be able to cope with the highest LHC luminosities. (Quasi)-homogeneous noble-liquid calorimeters are under construction or in the planning stage to address some of the most fundamental physics questions. (orig.)

  19. Calorimetry at industrial electron accelerators

    DEFF Research Database (Denmark)

    Miller, Arne; Kovacs, A.

    1985-01-01

    Calorimetry is a convenient way to measure doses at industrial electron accelerators, where high absorbed doses (1-100 kGy) are delivered at dose rates of 102-105 Gy s-1 or even higher. Water calorimeters have been used for this purpose for several years, but recently other materials such as grap......Calorimetry is a convenient way to measure doses at industrial electron accelerators, where high absorbed doses (1-100 kGy) are delivered at dose rates of 102-105 Gy s-1 or even higher. Water calorimeters have been used for this purpose for several years, but recently other materials...

  20. A study of gamma-irradiated polyethylenes by temperature modulated differential scanning calorimetry

    Science.gov (United States)

    Galovic, S.; Secerov, B.; Trifunovic, S.; Milicevic, D.; Suljovrujic, E.

    2012-09-01

    Various polyethylenes (PEs) and the effects of high-energy radiation on their structures were widely studied in the past using conventional Differential Scanning Calorimetry (DSC) measurements. In this work, we used the Temperature Modulated Differential Scanning Calorimetry (TMDSC) technique in order to obtain more information about the influence of the initial structural differences and gamma radiation on the evolution in structure and thermal properties of different polyethylenes. For this reason, low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) samples were exposed to gamma radiation, in air, to a wide range of absorbed doses (up to 2400 kGy). The separation of the total heat flow TMDSC signal into a reversing and non-reversing part enabled us to observe the low-temperature enthalpy relaxation (related to the existence of the "rigid amorphous phase") and recrystallisation processes, as well as to follow their radiation-induced evolution and/or that of melting in a more revealing manner compared to the case of the conventional DSC. Consequently, our results indicate that TMDSC could improve the understanding of radiation-induced effects in polymers.

  1. Study of Liquid Argon Dopants for LHC Hadron Calorimetry

    CERN Multimedia

    2002-01-01

    Hadron calorimetry based on the Liquid Argon Ionisation Chamber technique is one of the choice techniques for LHC-experimentation. A systematic study of the effect of selected dopants on Liquid Argon (LAr) will be carried out with the aim to achieve an improvement on: \\item (i)~``Fast Liquid Argon'' search and study of dopants to increase the drift velocity. It has been already shown that CH&sub4. added at a fraction of one percent increases the drift velocity by a factor of two or more. \\item (ii)~``Compensated Liquid Argon'' search and study of dopants to increase the response to densely ionising particles, resulting in improved compensation, such as photosensitive dopants. \\end{enumerate}\\\\ \\\\ Monitoring of the parameters involved in understanding the response of a calorimeter is essential. In case of doped LAr, the charge yield, the non-saturated drift velocity and the electron lifetime in the liquid should be precisely and simultaneously monitored as they all vary with the level of dopant concentrati...

  2. Impact of systolic blood pressure on the safety and tolerability of initiating and up-titrating sacubitril/valsartan in patients with heart failure and reduced ejection fraction: insights from the TITRATION study.

    Science.gov (United States)

    Senni, Michele; McMurray, John J V; Wachter, Rolf; McIntyre, Hugh F; Anand, Inder S; Duino, Vincenzo; Sarkar, Arnab; Shi, Victor; Charney, Alan

    2018-03-01

    The TITRATION trial investigated two strategies to initiate and up-titrate sacubitril/valsartan (LCZ696) to the same target dose, over a condensed (3-week) or conservative (6-week) period, in patients with heart failure with reduced ejection fraction (HFrEF) and systolic blood pressure (SBP) of ≥100 mmHg. This post hoc analysis examined the relationship between baseline SBP at screening and achievement of the target dose of sacubitril/valsartan of 97 mg/103 mg (also termed 'LCZ696 200 mg') twice per day during the study. Patients (n = 498) were categorized in four groups based on SBP at screening: 100-110 mmHg (n = 70); 111-120 mmHg (n = 93); 121-139 mmHg (n = 168) and ≥140 mmHg (n = 167). Overall, 72.7%, 76.1%, 85.6% and 82.9%, respectively, of patients in these SBP categories achieved and maintained the target dose of sacubitril/valsartan without down-titration/dose interruption over 12 weeks ('treatment success'). Compared with patients with SBP of 100-110 mmHg, rates of treatment success among patients in the higher SBP groups [111-120 mmHg (P = 0.96); 121-139 mmHg (P = 0.06) and ≥140 mmHg (P = 0.25)] did not differ significantly. A higher percentage of patients with lower SBP (100-110 mmHg) achieved treatment success with gradual up-titration (6 weeks) (∼80%) than with rapid up-titration (∼69%). Similar findings were observed with regard to 'tolerability success' (maintenance of the target dose for at least the final 2 weeks prior to study completion). Hypotension occurred more frequently in patients with lower SBP. The majority of patients (>80%) with SBP of ≥100 mmHg achieved and maintained the target dose of sacubitril/valsartan if the treatment was titrated gradually. These findings suggest that low SBP should not prevent clinicians from considering the initiation of sacubitril/valsartan. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of

  3. Determination of substances by radiothermometric titration

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.

    1976-01-01

    For determination, nitrogen is bubbled through a solution containing radioactive Kr, Xe, Rn or another aerogen in addition to the substance determined. A continuous or intermittent addition of the titrating solution results in the release of reaction heat, thus increasing the temperature of the reaction mixture, which releases a radioactive gas. Upon reaching the equivalence point, the cold titrating reagent cools the reaction mixture, thus reducing the radioactive substance release. The equivalence point lies at the point of intersection of the extended linear parts of the curve of the dependence of released radioactivity on the volume of the titrating solution added. (M.K.)

  4. Potentiometric Titration Method for Quantitative Determination of Hydrogen Peroxide

    National Research Council Canada - National Science Library

    Bessette, Russell R

    2005-01-01

    An electrochemical potentiometric titration method that entails titration of a known volume of a catholyte containing an unknown amount of hydrogen peroxide in a titration cell having two electrodes...

  5. Determination of milligram amounts of neptunium by potentiometric titration

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Solntseva, L.F.

    1981-01-01

    Two procedures of potentiometric titration of about 1 mg Np are reported which are based on its oxidation to neptunium (6) with silver (2) oxide followed by titration with iron (2) to neptunium (5) in one case and to neptunium (4) in the alternative one. The error is not greater than 0.2% rel. Ten-fold uranium excess does not interfere. Up to 1% of plutonium relative to neptunium does not interfere in the case of the titration to neptunium (5). In the titration to neptunium (4), plutonium is titrated stoichiometrically [ru

  6. Calorimetry energy measurement in particle physics

    CERN Document Server

    Wigmans, Richard

    2017-01-01

    Particle physics is the science that pursues the age-old quest for the innermost structure of matter and the fundamental interactions between its constituents. Modern experiments in this field rely increasingly on calorimetry, a detection technique in which the particles of interest are absorbed in the detector. Calorimeters are very intricate instruments. Their performance characteristics depend on subtle, sometimes counter-intuitive design details. This book, written by one of the world's foremost experts, is the first comprehensive text on this topic. It provides a fundamental and systematic introduction to calorimetry. It describes the state of the art in terms of both the fundamental understanding of calorimetric particle detection, and the actual detectors that have been or are being built and operated in experiments. The last chapter discusses landmark scientific discoveries in which calorimetry has played an important role. This book summarizes and puts into perspective the work described in some 900...

  7. A Tabular Approach to Titration Calculations

    Science.gov (United States)

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  8. Symmetry Properties of Potentiometric Titration Curves.

    Science.gov (United States)

    Macca, Carlo; Bombi, G. Giorgio

    1983-01-01

    Demonstrates how the symmetry properties of titration curves can be efficiently and rigorously treated by means of a simple method, assisted by the use of logarithmic diagrams. Discusses the symmetry properties of several typical titration curves, comparing the graphical approach and an explicit mathematical treatment. (Author/JM)

  9. Forward calorimetry in the upgraded UA1 experiment

    International Nuclear Information System (INIS)

    Alvarez-Taviel, F.J.; Diez-Hedo, F.; Doncel, P.; Marquina, M.A.; Rodrigo, T.; Bacci, C.; Petrolo, E.; Tusi, A.; Ferrando, A.; Givernaud, A.; Rubbia, C.; Vuillemin, V.

    1989-01-01

    The major improvement in the upgraded UA1 calorimetry at the Santi ppS is the general use of ionization chambers filled with tetramethylpentane (TMP) as a detection medium interspersed with uranium plates as absorber. To achieve overall uniformity of detection down to very small angles, an identical solution is proposed for the forward calorimetry. Forward calorimetry is essential for good total and missing energy measurement at high luminosity in view of the increasing rate of multiple collisions. Both designs for forward and very forward calorimeters are presented along with expected resolutions. (orig.)

  10. Percent relative cumulative frequency analysis in indirect calorimetry: application to studies of transgenic mice.

    Science.gov (United States)

    Riachi, Marc; Himms-Hagen, Jean; Harper, Mary-Ellen

    2004-12-01

    Indirect calorimetry is commonly used in research and clinical settings to assess characteristics of energy expenditure. Respiration chambers in indirect calorimetry allow measurements over long periods of time (e.g., hours to days) and thus the collection of large sets of data. Current methods of data analysis usually involve the extraction of only a selected small proportion of data, most commonly the data that reflects resting metabolic rate. Here, we describe a simple quantitative approach for the analysis of large data sets that is capable of detecting small differences in energy metabolism. We refer to it as the percent relative cumulative frequency (PRCF) approach and have applied it to the study of uncoupling protein-1 (UCP1) deficient and control mice. The approach involves sorting data in ascending order, calculating their cumulative frequency, and expressing the frequencies in the form of percentile curves. Results demonstrate the sensitivity of the PRCF approach for analyses of oxygen consumption (.VO2) as well as respiratory exchange ratio data. Statistical comparisons of PRCF curves are based on the 50th percentile values and curve slopes (H values). The application of the PRCF approach revealed that energy expenditure in UCP1-deficient mice housed and studied at room temperature (24 degrees C) is on average 10% lower (p lower environmental temperature, there were no differences in .VO2 between groups. The latter is likely due to augmented shivering thermogenesis in UCP1-deficient mice compared with controls. With the increased availability of murine models of metabolic disease, indirect calorimetry is increasingly used, and the PRCF approach provides a novel and powerful means for data analysis.

  11. Automated titration method for use on blended asphalts

    Science.gov (United States)

    Pauli, Adam T [Cheyenne, WY; Robertson, Raymond E [Laramie, WY; Branthaver, Jan F [Chatham, IL; Schabron, John F [Laramie, WY

    2012-08-07

    A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

  12. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules.

    Science.gov (United States)

    Hamidi-Asl, Ezat; Daems, Devin; De Wael, Karolien; Van Camp, Guy; Nagels, Luc J

    2014-12-16

    In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.

  13. Analyzing Protein Denaturation using Fast Differential Scanning Calorimetry

    NARCIS (Netherlands)

    Splinter, R.; Van Herwaarden, A.W.; Iervolino, E.; Vanden Poel, G.; Istrate, D.; Sarro, P.M.

    2012-01-01

    This paper investigates the possibility to measure protein denaturation with Fast Differential Scanning Calorimetry (FDSC). Cancer can be diagnosed by measuring protein denaturation in blood plasma using Differential Scanning Calorimetry (DSC). FDSC can reduce diagnosis time from hours to minutes,

  14. Error assessment in recombinant baculovirus titration: evaluation of different methods.

    Science.gov (United States)

    Roldão, António; Oliveira, Rui; Carrondo, Manuel J T; Alves, Paula M

    2009-07-01

    The success of baculovirus/insect cells system in heterologous protein expression depends on the robustness and efficiency of the production workflow. It is essential that process parameters are controlled and include as little variability as possible. The multiplicity of infection (MOI) is the most critical factor since irreproducible MOIs caused by inaccurate estimation of viral titers hinder batch consistency and process optimization. This lack of accuracy is related to intrinsic characteristics of the method such as the inability to distinguish between infectious and non-infectious baculovirus. In this study, several methods for baculovirus titration were compared. The most critical issues identified were the incubation time and cell concentration at the time of infection. These variables influence strongly the accuracy of titers and must be defined for optimal performance of the titration method. Although the standard errors of the methods varied significantly (7-36%), titers were within the same order of magnitude; thus, viral titers can be considered independent of the method of titration. A cost analysis of the baculovirus titration methods used in this study showed that the alamarblue, real time Q-PCR and plaque assays were the most expensive techniques. The remaining methods cost on average 75% less than the former methods. Based on the cost, time and error analysis undertaken in this study, the end-point dilution assay, microculture tetrazolium assay and flow cytometric assay were found to be the techniques that combine all these three main factors better. Nevertheless, it is always recommended to confirm the accuracy of the titration either by comparison with a well characterized baculovirus reference stock or by titration using two different methods and verification of the variability of results.

  15. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    Science.gov (United States)

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements

  16. Potentiometric titration of molybdenum (6) with a cathode-polarized solid electrode

    International Nuclear Information System (INIS)

    Boeva, L.V.; Kimstach, V.A.; Bagdasarov, K.N.

    1980-01-01

    The possibility has been studied of using solid electrodes for potentiometric precipitation titration of molybdenum (6). A cathode-polarized electrode, electrochemically covered with a molybdenum blue layer, can be used as indicator electrode. The best results were obtained during deposition of molybdenum blue on a tungsten electrode. The mechanism of electrode work during titration has been investigated. A procedure has been developed of titration of molybdenum (6) in acid solutions using hydroxylamine N-aryl derivatives as titrants

  17. Affinity between TBC1D4 (AS160 phosphotyrosine-binding domain and insulin-regulated aminopeptidase cytoplasmic domain measured by isothermal titration calorimetry

    Directory of Open Access Journals (Sweden)

    SangYoun Park*, Keon Young Kim, Sunmin Kim & Young Seok Yu

    2012-06-01

    Full Text Available Uptake of circulating glucose into the cells happens via the insulin-mediated signalling pathway, which translocates the glucosetransporter 4 (GLUT4 vesicles from the intracellular compartmentto the plasma membrane. RabㆍGTPases are involvedin this vesicle trafficking, where RabㆍGTPase-activatingproteins (RabGAP enhance the GTP to GDP hydrolysis.TBC1D4 (AS160 and TBC1D1 are functional RabGAPs in theadipocytes and the skeletonal myocytes, respectively. Theseproteins contain two phosphotyrosine-binding domains (PTBsat the amino-terminus of the catalytic RabGAP domain. Thesecond PTB has been shown to interact with the cytoplasmicregion of the insulin-regulated aminopeptidase (IRAP of theGLUT4 vesicle. In this study, we quantitatively measured the∼μM affinity (KD between TBC1D4 PTB and IRAP using isothermaltitration calorimetry, and further showed that IRAP residues1-49 are the major region mediating this interaction. Wealso demonstrated that the IRAP residues 1-15 are necessarybut not sufficient for the PTB interaction.

  18. An Olfactory Indicator for Acid-Base Titrations.

    Science.gov (United States)

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  19. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    Science.gov (United States)

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  20. Simple home-made sensors for potentiometric titrations

    International Nuclear Information System (INIS)

    Selig, W.

    1982-04-01

    A sensor for potentiometric titrations was prepared by coating a spectroscopic graphite rod with a solution of poly(vinyl chloride) and dioctyphthalate in tetrahydrofuran. The reference electrode was an Ag/AgCl single-junction electrode. The sensor was used in precipitation, acid-base, compleximetric, and redox titrations. Preparation of the coated-graphite sensor is simple and rapid. Moreover, it is quite inexpensive. A limitation is its applicability in aqueous media only, because organic solvents will dissolve the membrane. Various uncoated types of graphite have also been investigated as sensors, particularly in two applications of interest in the analysis of propellants: the titration of nitroform and perchlorate. Obviously, these sensors can be used also in nonaqueous, or partially nonaqueous media. These sensors may also find use in the potentiometric titration of fluoride vs La(III) or Th

  1. Linear Titration Curves of Acids and Bases.

    Science.gov (United States)

    Joseph, N R

    1959-05-29

    The Henderson-Hasselbalch equation, by a simple transformation, becomes pH - pK = pA - pB, where pA and pB are the negative logarithms of acid and base concentrations. Sigmoid titration curves then reduce to straight lines; titration curves of polyelectrolytes, to families of straight lines. The method is applied to the titration of the dipeptide glycyl aminotricarballylic acid, with four titrable groups. Results are expressed as Cartesian and d'Ocagne nomograms. The latter is of a general form applicable to polyelectrolytes of any degree of complexity.

  2. Novel titration method for surface-functionalised silica

    Energy Technology Data Exchange (ETDEWEB)

    Hofen, Kai; Weber, Siegfried [Department of Biotechnology, University of Applied Sciences, Mannheim (Germany); Chan, Chiu Ping Candace [School of Advanced Manufacturing and Mechanical Engineering, Mawson Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes 5095 (Australia); Majewski, Peter, E-mail: peter.majewski@unisa.edu.au [School of Advanced Manufacturing and Mechanical Engineering, Mawson Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes 5095 (Australia)

    2011-01-15

    This paper describes three inexpensive and fast analytical methods to characterise grafted particle surfaces. The reaction of silica with (3-aminopropyl)triethoxysilane, (3-mercaptopropyl)trimethoxysilane and N-(phosphonomethyl)iminodiacetic acid hydrate, respectively, leads to NH{sub 2}-, SO{sub 3}H- or COOH-functionalised silica, which were characterised by X-ray photoelectron spectrometry and titration in nonaqueous media as well as with two titration methods in a water-based environment. In the work presented, factors influencing the titrations are pointed out and solutions are presented to overcome these limiting factors are shown.

  3. Novel titration method for surface-functionalised silica

    International Nuclear Information System (INIS)

    Hofen, Kai; Weber, Siegfried; Chan, Chiu Ping Candace; Majewski, Peter

    2011-01-01

    This paper describes three inexpensive and fast analytical methods to characterise grafted particle surfaces. The reaction of silica with (3-aminopropyl)triethoxysilane, (3-mercaptopropyl)trimethoxysilane and N-(phosphonomethyl)iminodiacetic acid hydrate, respectively, leads to NH 2 -, SO 3 H- or COOH-functionalised silica, which were characterised by X-ray photoelectron spectrometry and titration in nonaqueous media as well as with two titration methods in a water-based environment. In the work presented, factors influencing the titrations are pointed out and solutions are presented to overcome these limiting factors are shown.

  4. Titrated Misoprostol Versus Dinoprostone for Labor Induction

    African Journals Online (AJOL)

    Aim: This study designed to compare titrated misoprostol regarding its safety and efficacy with dinoprostone for induction of labor. ... Statistical analysis done using Student's t-test for quantitative data and ..... induction: A pilot study. Rev Bras ...

  5. Digital movie-based on automatic titrations.

    Science.gov (United States)

    Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C

    2016-01-15

    This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Potentiometric titration and equivalent weight of humic acid

    Science.gov (United States)

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  7. Effect of Body Position on Energy Expenditure of Preterm Infants as Determined by Simultaneous Direct and Indirect Calorimetry.

    Science.gov (United States)

    Bell, Edward F; Johnson, Karen J; Dove, Edwin L

    2017-04-01

    Background  Indirect calorimetry is the standard method for estimating energy expenditure in clinical research. Few studies have evaluated indirect calorimetry in infants by comparing it with simultaneous direct calorimetry. Our purpose was (1) to compare the energy expenditure of preterm infants determined by these two methods, direct calorimetry and indirect calorimetry; and (2) to examine the effect of body position, supine or prone, on energy expenditure. Study Design  We measured energy expenditure by simultaneous direct (heat loss by gradient-layer calorimeter corrected for heat storage) and indirect calorimetry (whole-body oxygen consumption and carbon dioxide production) in 15 growing preterm infants during two consecutive interfeeding intervals, once in the supine position and once in the prone position. Results  The mean energy expenditure for all measurements in both positions did not differ significantly by the method used: 2.82 (standard deviation [SD] 0.42) kcal/kg/h by direct calorimetry and 2.78 (SD 0.48) kcal/kg/h by indirect calorimetry. The energy expenditure was significantly lower, by 10%, in the prone than in the supine position, whether examined by direct calorimetry (2.67 vs. 2.97 kcal/kg/h, p  Direct calorimetry and indirect calorimetry gave similar estimates of energy expenditure. Energy expenditure was 10% lower in the prone position than in the supine position. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Potentiometric titration of free acid in uranium solutions

    International Nuclear Information System (INIS)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors' researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors' researches are appended. (author). 26 refs., 54 figs

  9. Potentiometric titration of free acid in uranium solutions

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors` researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors` researches are appended. (author). 26 refs., 54 figs.

  10. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    Science.gov (United States)

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P CPAP titration level (P CPAP titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  11. Electroconvulsive therapy stimulus titration: Not all it seems.

    Science.gov (United States)

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  12. Calorimetry at the SSC

    International Nuclear Information System (INIS)

    Wigmans, R.

    1987-09-01

    The state of the art, and our present understanding of the basic limitations in hadron calorimetry, are briefly described. The various options for SSC calorimeters are discussed, and the R and D needed for the ones that look most promising is outlined. 13 refs.; 8 figs

  13. NBL-Davies-Gray weight titration method

    International Nuclear Information System (INIS)

    Hassell, C.

    1981-01-01

    The titration method for uranium consists of the following basic steps: reduction of U +6 to U +4 by Fe +2 ; selective oxidation of excess Fe +2 by HNO 3 with Mo +6 catalyst, all in strong phosphoric acid solution; and titration of the U +4 with standard dichromate after dilution. In this paper, detailed procedure of the NBL method, its modification to a gravimetric system or weight titration technique, and miniaturization of the NBL titrimetric method are discussed. Improved precisions and accuracy (2 to 3 times), of the gravimetric titrant delivery has made it possible to reduce the amount of uranium taken for each analysis. At present, using gravimetric delivery, most samples are titrated in the 30 to 50 mg range. Improved precision has led to investigating the possibility of a scaled-down version of the basic method so as to reduce the volume of phosphoric acid waste generated. Because all reactions are carried out in the same vessel, this method can be automated. Analysts at NBL have been able to restrict error to 0.05% or better in the 30 to 100 mg range using the basic procedure

  14. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    Science.gov (United States)

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  15. Thermometric titration in investigation of the formation of polyanions of molybdenum(VI), tungsten(VI), vanadium(V), and chromium (VI)-I: comparison of thermometric and potentiometric titration curves.

    Science.gov (United States)

    Kiba, N; Takeuchi, T

    1973-09-01

    A new twin-cell thermometric titrator has been devised and used for thermometric titration of solutions of sodium molybdate, sodium tungstate, sodium orthovanadate, ammonium metavanadate, and potassium chromate with perchloric acid. The thermometric titration curves were compared with corresponding pH-titration curves for elucidation of the reactions occurring in the titrations. Thermometric titrimetric methods have been developed for the determination of tungsten, vanadium and chromium.

  16. Quick titration of pergolide in cotreatment with domperidone is safe and effective

    NARCIS (Netherlands)

    Jansen, PAF; Herings, RMC; Samson, MM; Schuurmans-Daemen, LMPJ; Hovestadt, A; Verhaar, HJJ; Van Laar, T; de Vreede, P.

    2001-01-01

    The purpose of the study was to analyze efficacy and safety of quick pergolide titration combined with domperidone. In an open-label prospective study, pergolide was titrated in 16 days to a maximum of 3 mg/d doses as adjunctive treatment to L-Dopa in 10 elderly patients with Parkinson's disease.

  17. Liquid Argon Calorimetry with LHC-Performance Specifications

    CERN Multimedia

    2002-01-01

    % RD-3 Liquid Argon Calorimetry with LHC-Performance Specifications \\\\ \\\\Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. Among the techniques used so far, or under development, the liquid argon sampling calorimetry offers high radiation resistence, good energy resolution (electromagnetic and hadronic), excellent calibration stability and response uniformity. Its rate capabilities, however, do not yet match the requirements for LHC. \\\\ \\\\The aim of this proposal is to improve the technique in such a way that high granularity, good hermiticity and adequate rate capabilities are obtained, without compromising the above mentioned properties. To reach this goal, we propose to use a novel structure, the $^{\\prime\\prime}$accordion$^{\\prime\\prime}$, coupled to fast preamplifiers working at liquid argon temperature. Converter and readout electrodes are no longer planar and perpendicular to particles, as usual, but instead they are wiggled around a plane containing particles. ...

  18. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    Science.gov (United States)

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    Science.gov (United States)

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  20. Two-phase titration of cerium(III) by permanganate

    International Nuclear Information System (INIS)

    Lazarev, A.I.; Lazareva, V.I.; Gerko, V.V.

    1987-01-01

    This paper presents a method for the two-phase titrimetric determination of cerium(III) with permanganate which does not require an expenditure of sugar and preliminary removal of chlorides and nitrates. The interaction of cerium(III) with permanganate at room temperature was studied as a function of the pH, the concentration of pyrophosphate, tetraphenylphosphonium (TPP), permanganate, and extraneous compounds, the rate of titration, and the time of stay of the solution in air before titration. The investigations were conducted according to the following methodology: water, solution of cerium(III) pyrophosphate, and TPP were introduced into an Erlenmeyer flask with a side branch near the bottom for clearer observation of the color of the chloroform phase. The authors established the given pH value, poured the water into a volume of 50 ml, and added chloroform. The result was titrated with permanganate solutions of various concentrations until a violet color appeared in the chloroform phase

  1. A computer controlled potentiometric titrator for quantitative determination of uranium

    International Nuclear Information System (INIS)

    Verdingh, V.; Michiels, A.

    1988-01-01

    The modified Davies and Gray methods is frequently used for the potentiometric titration of uranium. It is based upon the reduction of U(VI) to U(IV) with a reductant (e.g. Fe ++ ) followed by a selective oxidation of the excess of reductant and subsequent titration of U(IV) with potassium dichromate (K 2 Cr 2 O 7 ). Interference from other elements is low, but the method is rather cumbersome due to the number of reactants to be added before the titration is started. The timing of these additions also plays a role. In order to render the titration less dependent on human factors and with the aim of reaching high reproducibility, a computer controlled system has been designed and set-up. Reagents are added by five computer controlled burettes. A program allows the choice of volumes and waiting times, and commands the start of the final titration which is followed by the microprocessor of the automatic potentiometric titrator. In this way a routine uranium titration can be completed in about twelve minutes. Reproducibilities of the order of ±15% are achievable in routine operation. For high precision work, the titrator is used as an end-point detector. Titrant is added manually by mass, so as to react with > 99% of the uranium. The residual uranium is then titrated automatically by colume with diluted titrant. The precision can be improved by a factor of approximately ten. (orig.)

  2. Non-aqueous titration of benzotrifuroxan (BTF)

    Energy Technology Data Exchange (ETDEWEB)

    Selig, W.

    1978-01-01

    This compound can be titrated potentiometrically as an acid with tetrabutylammonium hydroxide in dimethylformamide, dimethylsulfoxide, acetone, pyridine, tetramethylguanidine. The solvent of choice is dimethylformamide which yields the steepest titration curve and the lowest standard deviation. The equivalent weight of benzotrifuroxan is dependent on the solvent used indicating a strong interaction with the solvent. In dimethylformamide, the equivalent weight of benzotrifuroxan is 151.3, corresponding to 1.67 equivalents per mole.

  3. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    Science.gov (United States)

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  4. Interactions between poly(acrylic acid) and sodium dodecyl sulfate: isothermal titration calorimetric and surfactant ion-selective electrode studies.

    Science.gov (United States)

    Wang, C; Tam, K C

    2005-03-24

    Interaction between a monodispersed poly(acrylic acid) (PAA) (M(W) = 5670 g/mol, M(w)/M(n) = 1.02) with sodium dodecyl sulfate (SDS) was investigated using isothermal titration calorimetry (ITC), ion-selective electrode (ISE), and dynamic light scattering measurements. Contrary to previous studies, we report for the first time evidence of interaction between SDS and PAA when the degree of neutralization (alpha) of PAA is lower than 0.2. Hydrocarbon chains of SDS cooperatively bind to apolar segments of PAA driven by hydrophobic interaction. The interaction is both enthalpy and entropy favored (deltaH is negative but deltaS is positive). In 0.05 wt % PAA solution, the SDS concentration corresponding to the onset of binding (i.e., CAC) is approximately 2.4 mM and the saturation concentration (i.e., C(S)) is approximately 13.3 mM when alpha = 0. When PAA was neutralized and ionized, the binding was hindered by the enhanced electrostatic repulsion between negatively charged SDS and PAA chains and improved solubility of the polymer. With increasing alpha to 0.2, CAC increases to approximately 6.2 mM, C(S) drops to 8.6 mM, and the interaction is significantly weakened where the amount of bound SDS on PAA is reduced considerably. The values of CAC and C(S) derived from different techniques are in good agreement. The binding results in the formation of mixed micelles on apolar PAA coils, which then expands and dissociates into single PAA chains. The majority of unneutralized PAA molecules exist as single polymer chains stabilized by bound SDS micelles in solution after the saturation concentration.

  5. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  6. Monitoring Acid–Base Titrations on Wax Printed Paper Microzones Using a Smartphone

    Directory of Open Access Journals (Sweden)

    Sandro A. Nogueira

    2017-05-01

    Full Text Available This study describes the use of a smartphone for monitoring acid–base titrations on wax printed paper microzones. An array of twelve microzones of 5 mm diameter each was wax printed on filter paper. The analytical performance of the proposed devices was explored with acid–base titrations examples, where jaboticaba peel extract was used as a natural pH indicator. The color intensity was captured using a smartphone and analyzed through a free App named Photometrix®. Before titrations, color intensity versus pH was calibrated to be used as a reference in titrations as (i strong acid versus strong base; (ii strong base versus strong acid; and (iii weak acid versus strong base. In all examples, images were obtained after the addition of each aliquot of titrant solutions. The obtained titration curves showed the same behavior as the conventional titration curves. After evaluating the feasibility of the proposed methodology, the concentration level of acetic acid was obtained in three vinegar samples. Although the obtained values ranged from 5% to 8% compared to the concentrations on the conventional method, the proposed methodology presented high analytical reliability. The calculated concentrations of acetic acid in three samples ranged from 3.87% to 3.93%, and the proposed methodology did not significantly differ from classic acid–base titration at a confidence level of 95%. The acid–base titration on paper-based devices is outstanding, since any titration can be completed within 5 min using 20 µL volumes. Besides, the use of a smartphone to capture images followed by analysis in a free app offers simplicity to all users. The proposed methodology arises as a new strand to be exploited in the diffusion of the analytical chemistry education field as well as an alternative for quantitative analysis with extremely simplified instrumentation.

  7. Aqueous solutions of proline and NaCl studied by differential scanning calorimetry at subzero temperatures

    DEFF Research Database (Denmark)

    Rasmussen, Peter Have; Jørgensen, Bo; Nielsen, Jette

    1997-01-01

    The hydration properties of proline are studied by differential scanning calorimetry (DSC) in aqueous solutions during freezing to -60 degrees C and subsequent heating to +20 degrees C. The concentration of proline in the freeze concentrated solution was estimated to approximately 50 wt% (w/w) in...... plants and insects living under water stress conditions is discussed. (C) 1997 Elsevier Science B.V....

  8. Acid/base titrations of simulated PWR crevice environments

    International Nuclear Information System (INIS)

    Pang, J.; Macdonald, D.D.; Millett, P.J.

    1993-01-01

    The construction and operation of a titration system that is capable of exploring the acid/base properties of aqueous systems at temperatures solution is measured using YSZ sensors of the type Hg/HgO/ZrO 2 (Y 2 O 3 )/Solution in conjunction with a suitable reference electrode. The use of the system for measuring the pH of the titrated solutions (NaOH/H 2 SO 4 ) is discussed, and we show that the YSZ pH sensor is capable of consistent and precise pH measurements at elevated temperature (275-325 degrees C) and pressures (100-150 bars). However, the accuracy of the measured pH depends critically on the performance of the reference electrode. In the present work, we ensure the viability of the reference electrode. In the present work, we ensure the viability of the reference electrode by periodically calibrating it in situ using the pH sensor and a standard solution of known pH versus temperature characteristics. The titration data obtained in this study are compared with predictions from EPRI's MULTEQ code, and are found to be in satisfactory agreement in the alkaline pH region. Observed discrepancies in the acidic pH region between the two sets of data are attributed to corrosion of the alloys used to fabricate the titration system

  9. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  10. Isothermal titration calorimetry of sorption processes. A promising approach

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Norbert; Foerstendorf, Harald [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Surface Processes; Drobot, B. [Technische Univ. Dresden (Germany); Fahmy, Karim [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Biophysics; Reder, Christian

    2017-06-01

    As a consequence of nuclear waste disintegration heat, elevated temperatures in the near field may influence radionuclide retention significantly. However, there is a nearly complete lack of spectroscopic investigations of sorption processes at elevated temperatures. In addition, experimental data on free Gibbs energy (Δ{sub R}G), enthalpy (Δ{sub R}H) and entropy (Δ{sub R}S) of reactions of most radionuclides including fission products such as {sup 79}Se are sparse. Using the Se(IV)/hematite system, we show that microcalorimetry can provide these thermodynamic parameters with high accuracy and in a manner that allows studying various radionuclides.

  11. Implementation of a pharmacist-managed heart failure medication titration clinic.

    Science.gov (United States)

    Martinez, Amanda S; Saef, Jerold; Paszczuk, Anna; Bhatt-Chugani, Hetal

    2013-06-15

    The development, implementation, and initial results of a pharmacist-managed heart failure (HF) medication titration clinic are described. In a quality-improvement initiative at a Veterans Affairs health care system, clinical pharmacists were incorporated into the hospital system's interprofessional outpatient HF clinic. In addition, a separate pharmacist-managed HF medication titration clinic was established, in which pharmacists were granted an advanced scope of practice and prescribing privileges, enabling them to initiate and adjust medication dosages under specific protocols jointly established by cardiology and pharmacy staff. Pharmacists involved in the titration clinic tracked patients' daily body weight, vital signs, and volume status using telephone-monitoring technology and via patient interviews. A retrospective chart review comparing achievement of target doses of angiotensin-converting enzyme inhibitor (ACEI), angiotensin-receptor blocker (ARB), and β-blocker therapies in a group of patients (n = 28) whose dosage titrations were carried out by nurses or physicians prior to implementation of the pharmacist-managed HF medication titration clinic and a group of patients (n = 27) enrolled in the medication titration clinic during its first six months of operation indicated that target ACEI and ARB doses were achieved in a significantly higher percentage of pharmacist-managed titration clinic enrollees (52.9% versus 31%, p = 0.007). Patients enrolled in the pharmacist-managed HF medication titration clinic also had a significantly higher rate of attainment of optimal β-blocker doses (49% versus 24.7%, p = 0.012). Implementation of a pharmacist-managed HF medication titration clinic increased the percentage of patients achieving optimal ACEI, ARB, and β-blocker dosages.

  12. Development of Resistive Micromegas for Sampling Calorimetry

    Science.gov (United States)

    Geralis, T.; Fanourakis, G.; Kalamaris, A.; Nikas, D.; Psallidas, A.; Chefdeville, M.; Karyotakis, I.; Koletsou, I.; Titov, M.

    2018-02-01

    Resistive micromegas is proposed as an active element for sampling calorimetry. Future linear collider experiments or the HL-LHC experiments can profit from those developments for Particle Flow Calorimetry. Micromegas possesses remarkable properties concerning gain stability, reduced ion feedback, response linearity, adaptable sensitive element granularity, fast response and high rate capability. Recent developments on Micromegas with a protective resistive layer present excellent results, resolving the problem of discharges caused by local high charge deposition, thanks to its RC-slowed charge evacuation. Higher resistivity though, may cause loss of the response linearity at high rates. We have scanned a wide range of resistivities and performed laboratory tests with X-rays that demonstrate excellent response linearity up to rates of (a few) times 10MHz/cm2, with simultaneous mitigation of discharges. Beam test studies at SPS/CERN with hadrons have also shown a remarkable stability of the resistive Micromegas and low currents for rates up to 15MHz/cm2. We present results from the aforementioned studies confronted with MC simulation

  13. Computer controlled titration with piston burette or peristaltic pump - a comparison.

    Science.gov (United States)

    Hoffmann, W

    1996-09-01

    The advantages and problems of the use of piston burettes and peristaltic pumps for dosage of titrant solutions in automatic titrations are shown. For comparison, only the dosing devices were exchanged and all other components and conditions remained unchanged. The results of continuous acid base titration show good agreement and comparable reproducibility. Potentiometric sensors (glass electrodes) with different equilibration behaviour influence the results. The capability of such electrodes was tested. Conductometric measurements allow a much faster detection because there is no equilibration of electrodes. Piston burettes should be used for titration with very high precision, titration with organic solvents and slow titrations. Peristaltic pumps seem to be more suitable for continuous titrations and long time operation without service.

  14. Pilot study of a new device to titrate oxygen flow in hypoxic patients on long-term oxygen therapy.

    Science.gov (United States)

    Cirio, Serena; Nava, Stefano

    2011-04-01

    The O(2) Flow Regulator (Dima, Bologna, Italy) is a new automated oxygen regulator that titrates the oxygen flow based on a pulse-oximetry signal to maintain a target S(pO(2)). We tested the device's safety and efficacy. We enrolled 18 subjects with chronic lung disease, exercise-induced desaturation, and on long-term oxygen therapy, in a randomized crossover study with 2 constant-work-load 15-min cycling exercise tests, starting with the patient's previously prescribed usual oxygen flow. In one test the oxygen flow was titrated manually by the respiratory therapist, and in the other test the oxygen flow was titrated by the O(2) Flow Regulator, to maintain an S(pO(2)) of 94%. We measured S(pO(2)) throughout each test, the time spent by the respiratory therapist to set the device or to manually regulate the oxygen flow, and the total number of respiratory-therapist titration interventions during the trial. There were no differences in symptoms or heart rate between the exercise tests. Compared to the respiratory-therapist-controlled tests, during the O(2) Flow Regulator tests S(pO(2)) was significantly higher (95 ± 2% vs 93 ± 3%, P = .04), significantly less time was spent below the target S(pO(2)) (171 ± 187 s vs 340 ± 220 s, P less respiratory therapist time (5.6 ± 3.7 min vs 2.0 ± 0.1 min, P = .005). The O(2) Flow Regulator may be a safe and effective alternative to manual oxygen titration during exercise in hypoxic patients. It provided stable S(pO(2)) and avoided desaturations in our subjects.

  15. Titration in the treatment of the more troubled patient.

    Science.gov (United States)

    Winer, J A; Ornstein, E D

    2001-01-01

    This article defines and discusses a modification of technique recommended by the authors in the psychoanalytic treatment of more troubled patients--a modification they call titration. Titration is defined as a conscious decision by the analyst to increase or decrease assistance (or gratification) gradually, in order to facilitate the analytic process. The authors emphasize the complexity of decisions in treatment by focusing on the decision-making processes that titration requires. Guidelines and a case vignette are presented. The authors conclude by considering some of the politics involved in the introduction of technique modifications, the salience of the titration concept, and directions for further exploration.

  16. Rapid clozapine titration in treatment-refractory bipolar disorder.

    Science.gov (United States)

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Kinetic Titration Series with Biolayer Interferometry

    Science.gov (United States)

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  18. Potentiometric determination of milligram amounts of uranium by semiautomatic titrator

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Stepanov, A.V.; Preobrazhenskaya, L.D.; Solntseva, L.F.; Gromova, E.A.

    1978-01-01

    A semiautomatic titrator is described which allows gravimetriotentiometricc-p titrat mg amounts of substances. Milligram amounts of uranium (absolute contents and oxygen/uranium ratio) in U 3 O 8 were determined as an example of the titrator action. The relative standard deviation was less than 0.001

  19. Thermodynamics and structure of inclusion compounds of tauro- and glyco-conjugated bile salts and beta-cyclodextrin

    DEFF Research Database (Denmark)

    Holm, Rene; Shi, Wei; Andersen Hartvig, Rune

    2009-01-01

    The interaction between natural beta-cyclodextrin and bile salts common in rat, dog and man, taurocholate, tauro-beta-muricholate, taurodeoxycholate, taurochenodeoxycholate, glycocholate, glycodeoxycholate and glycochenodeoxycholate, was studied using isothermal titration calorimetry, and the str......The interaction between natural beta-cyclodextrin and bile salts common in rat, dog and man, taurocholate, tauro-beta-muricholate, taurodeoxycholate, taurochenodeoxycholate, glycocholate, glycodeoxycholate and glycochenodeoxycholate, was studied using isothermal titration calorimetry......, and the structural differences in the interaction were investigated by H-1-ROESY NMR and molecular modeling. The beta-cyclodextrin was selected based upon its frequent use in preformulation and drug formulation as oral excipients for the solubilization of drug substances with low aqueous solubility. All...

  20. Kinetics of enzymatic high-solid hydrolysis of lignocellulosic biomass studied by calorimetry.

    Science.gov (United States)

    Olsen, Søren N; Lumby, Erik; McFarland, Kc; Borch, Kim; Westh, Peter

    2011-03-01

    Enzymatic hydrolysis of high-solid biomass (>10% w/w dry mass) has become increasingly important as a key step in the production of second-generation bioethanol. To this end, development of quantitative real-time assays is desirable both for empirical optimization and for detailed kinetic analysis. In the current work, we have investigated the application of isothermal calorimetry to study the kinetics of enzymatic hydrolysis of two substrates (pretreated corn stover and Avicel) at high-solid contents (up to 29% w/w). It was found that the calorimetric heat flow provided a true measure of the hydrolysis rate with a detection limit of about 500 pmol glucose s(-1). Hence, calorimetry is shown to be a highly sensitive real-time method, applicable for high solids, and independent on the complexity of the substrate. Dose-response experiments with a typical cellulase cocktail enabled a multidimensional analysis of the interrelationships of enzyme load and the rate, time, and extent of the reaction. The results suggest that the hydrolysis rate of pretreated corn stover is limited initially by available attack points on the substrate surface (conversion) but becomes proportional to enzyme dosage (excess of attack points) at later stages (>10% conversion). This kinetic profile is interpreted as an increase in polymer end concentration (substrate for CBH) as the hydrolysis progresses, probably due to EG activity in the enzyme cocktail. Finally, irreversible enzyme inactivation did not appear to be the source of reduced hydrolysis rate over time.

  1. Kinetics of bacterial potentiometric titrations: the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions.

    Science.gov (United States)

    Kapetas, Leon; Ngwenya, Bryne T; Macdonald, Alan M; Elphick, Stephen C

    2011-07-15

    Several recent studies have made use of continuous acid-base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titrations and test the effect they have on the derivation of functional group concentrations and acidity constants. We titrated suspensions of Pantoea agglomerans by varying the equilibration time between successive titrant additions until stability of 0.1 or 0.001 mV s(-1) was attained. We show that under longer equilibration times, titration results are less reproducible and suspensions exhibit marginally higher buffering. Fluorescence images suggest that cell lysis is not responsible for these effects. Rather, high DOC values and titration reversibility hysterisis after long equilibration times suggest that variability in buffering is due to the presence of bacterial exudates, as demonstrated by titrating supernatants separated from suspensions of different equilibration times. It is recommended that an optimal equilibration time is always determined with variable stability control and preliminary reversibility titration experiments. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Molybdenum (6) determination by the method of high-frequency and pH titration

    International Nuclear Information System (INIS)

    Lukianets, I.G.; Kulish, N.G.

    1981-01-01

    A possibility to determine Mo(6) using the method of high frequency and pH-metric titration is investigated. By means of the high frequency contact R-cell Mo(6) titration is performed using different precipitators: 8-oxiquinoline, lead nitrate and acetate and silver nitrate. It is established that the best conditions are achieved during titration of 67.2-1343 mg/10 ml Mo(6) with lead acetate (pH 4.5-6.5). Relative standard deviation Ssub(r) constitutes 0.005 pH-metric titration of Mo(6) with complexone 3 is studied. The range of Mo(6) concentrations determined constitutes 13.43-134.3 mg at pH initial value of 3.5-5.5. Relative standard deviation Ssub(r) constitutes 0.003. Techniques of molybdenum determination in ferromolybdenum using the method of high frequency and pH-metric titration are developed [ru

  3. Synergy of molecular dynamics and isothermal titration calorimetry in studies of Allostery

    Czech Academy of Sciences Publication Activity Database

    Strawn, R.; Stockner, T.; Melicherčík, Milan; Jin, L.; Xue,, W. F.; Carey, J.; Ettrich, Rüdiger

    2011-01-01

    Roč. 492, - (2011), s. 151-188 ISSN 0076-6879 R&D Projects: GA MŠk(CZ) LC06010; GA ČR GAP207/10/1934 Institutional research plan: CEZ:AV0Z60870520 Keywords : hexameric arginine repressor * DNA-binding domain * escherichia-coli * ligand-binding * bacillus-stearothhermophilus * proteins * systems * model * simulations * operator Subject RIV: EH - Ecology, Behaviour Impact factor: 2.042, year: 2011

  4. Methodology of hot nucleus calorimetry and thermometry produced by nuclear reactions around Fermi energies; Methodologie de la calorimetrie et de la thermometrie des noyaux chauds formes lors de collisions nucleaires aux energies de Fermi

    Energy Technology Data Exchange (ETDEWEB)

    Vient, E

    2006-12-15

    This work deals with the calorimetry and thermometry of hot nuclei produced in collisions Xe + Sn between 25 and 100 MeV/u. The apparatus for hot nucleus physical characterization is the 4{pi} detector array Indra. This study was made by using the event generators Gemini, Simon and Hipse and a data-processing filter simulating the complete operation of the multi-detector. The first chapter presents the different ways of producing hot nuclei. In the second and third chapters, the author presents a critical methodological study of calorimetry and thermometry applied to hot nuclei, different methods are reviewed, their accuracy and application range are assessed. All the calorimetry methods rely on the assumption that we are able to discriminate decay products of the hot nucleus from evaporated particles. In the fourth chapter, the author gives some ways of improving calorimetry characterization of the hot nucleus. An alternative method of calorimetry is proposed in the fifth chapter, this method is based on the experimental determination of an evaporation probability that is deduced from the physical characteristics of the particles present in a restricted domain of the space of velocities.

  5. Detectors for Linear Colliders: Calorimetry at a Future Electron-Positron Collider (3/4)

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    Calorimetry will play a central role in determining the physics reach at a future e+e- collider. The requirements for calorimetry place the emphasis on achieving an excellent jet energy resolution. The currently favoured option for calorimetry at a future e+e- collider is the concept of high granularity particle flow calorimetry. Here granularity and a high pattern recognition capability is more important than the single particle calorimetric response. In this lecture I will describe the recent progress in understanding the reach of high granularity particle flow calorimetry and the related R&D efforts which concentrate on test beam demonstrations of the technological options for highly granular calorimeters. I will also discuss alternatives to particle flow, for example the technique of dual readout calorimetry.

  6. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  7. Barriers to and enablers of insulin self-titration in adults with Type 2 diabetes: a qualitative study.

    Science.gov (United States)

    McBain, H; Begum, S; Rahman, S; Mulligan, K

    2017-02-01

    To identify the barriers to and enablers of effective insulin self-titration in people with Type 2 diabetes. A qualitative semi-structured interview approach was used. Questions were structured according to the Theoretical Domains Framework, which outlines 14 domains that can act as barriers to and enablers of changing behaviour. Interviews were audio-recorded and transcribed verbatim. The data were coded according to the 14 domains, belief statements were created within each domain, and a frequency count of the most reported barriers and enablers was then carried out. Analyses were conducted by two researchers, and discrepancies agreed with a third researcher. A total of 18 adults with Type 2 diabetes took part in an interview. The majority were of South-Asian ethnicity (n = 8) and were men (n = 12). Their mean age was 61 years old. The mean duration of diabetes was 16 years and time on insulin 9 years. Inter-rater reliability for each of the domains varied (29-100%). The most frequently reported domains were Social Influence and Beliefs about Consequences; the least frequently reported were Optimism and Reinforcement. Interviewees reported receiving support to self-titrate from a range of sources. Self-titrating was perceived to have a range of both positive and negative consequences, as was not titrating. The findings highlight that those interviewed experienced a range of barriers and enablers when attempting to self-titrate. Improved education and training when initiating insulin treatment among adults with Type 2 diabetes, and throughout their journey on insulin therapy could help identify and address these barriers in order to optimize self-titration. © 2016 Diabetes UK.

  8. Safety and tolerability of different titration rates of retigabine (ezogabine) in patients with partial-onset seizures.

    Science.gov (United States)

    Biton, Victor; Gil-Nagel, Antonio; Brodie, Martin J; Derossett, Sarah E; Nohria, Virinder

    2013-11-01

    Retigabine (RTG; international nonproprietary name)/ezogabine (EZG; US adopted name) is an antiepileptic drug (AED) that prolongs neuronal voltage-gated potassium-channel KCNQ2-5 (Kv 7.2-7.5) opening. This double-blind study evaluated different RTG/EZG dose-titration rates. Patients (N=73) with partial-onset seizures receiving concomitant AEDs were randomized to one of three titration groups, all of which were initiated at RTG/EZG 300mg/day divided into three equal doses. Fast-, medium-, and slow-titration groups received dose increments of 150mg/day every 2, 4, and 7 days, respectively, achieving the target dose of 1200mg/day after 13, 25, and 43 days, respectively. Safety assessments were performed throughout. Discontinuation rates due to treatment-emergent adverse events (TEAEs) were numerically higher in the fast- (10/23) and medium- (7/22) titration groups than in the slow-titration group (3/23) but statistical significance was achieved only for the high-titration group compared with the low-titration group (p=0.024). Stratified analysis, with concomitant AEDs divided into enzyme inducers (carbamazepine, phenytoin, oxcarbazepine) or noninducers, showed that the risk of discontinuation due primarily to TEAEs was significantly higher in the fast- (p=0.010) but not in the medium-titration group (p=0.078) when compared with the slow-titration group. Overall, the slow-titration rate appeared to be best tolerated and was used in further efficacy and safety studies with RTG/EZG. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    Science.gov (United States)

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  10. Developing a Physiotherapy-Specific Preliminary Clinical Decision-Making Tool for Oxygen Titration: A Modified Delphi Study

    Science.gov (United States)

    Duong, Michelle; Bertin, Kendra; Henry, Renee; Singh, Deepti; Timmins, Nolla; Brooks, Dina; Mathur, Sunita

    2014-01-01

    ABSTRACT Purpose: To develop and evaluate a preliminary clinical decision-making tool (CDMT) to assist physiotherapists in titrating oxygen for acutely ill adults in Ontario. Methods: A panel of 14 experienced cardiorespiratory physiotherapists was recruited. Factors relating to oxygen titration were identified using a modified Delphi technique. Four rounds of questionnaires were conducted, during which the goals were to (1) generate factors, (2) reduce factors and debate contentious factors, (3) finalize factors and develop the preliminary CDMT, and (4) evaluate the usability of the tool in a clinical context. Results: The panel reached consensus on a total of 89 factors, which were compiled to create the preliminary CDMT. The global tool reached consensus for sensibility, receiving a mean score of 6/7 on a 7-point Likert-type scale (1=unacceptable; 7=excellent). Five of the nine individual components of evaluation of the tool achieved scores ≥6.0; the remaining four had mean scores between 5.4 and 5.9. Conclusion: This study produced a preliminary CDMT for oxygen titration, which the panel agreed was highly comprehensible and globally sensible. Further research is necessary to evaluate the sensibility and applicability of the tool in a clinical setting. PMID:25125782

  11. Differential scanning calorimetry techniques: applications in biology and nanoscience.

    Science.gov (United States)

    Gill, Pooria; Moghadam, Tahereh Tohidi; Ranjbar, Bijan

    2010-12-01

    This paper reviews the best-known differential scanning calorimetries (DSCs), such as conventional DSC, microelectromechanical systems-DSC, infrared-heated DSC, modulated-temperature DSC, gas flow-modulated DSC, parallel-nano DSC, pressure perturbation calorimetry, self-reference DSC, and high-performance DSC. Also, we describe here the most extensive applications of DSC in biology and nanoscience.

  12. Differential Scanning Calorimetry Techniques: Applications in Biology and Nanoscience

    OpenAIRE

    Gill, Pooria; Moghadam, Tahereh Tohidi; Ranjbar, Bijan

    2010-01-01

    This paper reviews the best-known differential scanning calorimetries (DSCs), such as conventional DSC, microelectromechanical systems-DSC, infrared-heated DSC, modulated-temperature DSC, gas flow-modulated DSC, parallel-nano DSC, pressure perturbation calorimetry, self-reference DSC, and high-performance DSC. Also, we describe here the most extensive applications of DSC in biology and nanoscience.

  13. Biocoordination chemistry. pH-metry titration method during study of biometal complexing with bioligands

    International Nuclear Information System (INIS)

    Dobrynina, N.A.

    1992-01-01

    Position of bioinorganic chemistry in the system of naturl science, as well as relations between bioinorganic and biocoordination chemistry, were considered. The content of chemical elements in geosphere and biosphere was analyzed. Characteristic features of biometal complexing with bioligands were pointed out. By way of example complex equilibria in solution were studie by the method of pH-metric titration using mathematical simulation. Advantages of the methods totality, when studying biosystems, were emphasized

  14. A Closer Look at Acid-Base Olfactory Titrations

    Science.gov (United States)

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  15. Calorimetry at the SSC

    International Nuclear Information System (INIS)

    Wigmans, R.

    1988-01-01

    The state of the art, and the present understanding of the basic limitations in hadron calorimetry, are briefly described. The various options for SSC calorimeters are discussed, and the R ampersand D needed for the ones that look most promising is outlined. The most promising candidates are (1) lead/scintillating fibers and (2) lead (or uranium)/TMS (or other warm liquids)

  16. Safety of the Up-titration of Nifedipine GITS and Valsartan or Low-dose Combination in Uncontrolled Hypertension: the FOCUS Study.

    Science.gov (United States)

    Park, Jeong Bae; Shin, Joon-Han; Kim, Dong-Soo; Youn, Ho-Joong; Park, Seung Woo; Shim, Wan Joo; Park, Chang Gyu; Kim, Dong-Woon; Lee, Hae-Young; Choi, Dong-Ju; Rim, Se-Joong; Lee, Sung-Yun; Kim, Ju-Han

    2016-04-01

    Doubling the dose of antihypertensive drugs is necessary to manage hypertension in patients whose disease is uncontrolled. However, this strategy can result in safety issues. This study compared the safety and efficacy of up-titration of the nifedipine gastrointestinal therapeutic system (GITS) with up-titration of valsartan monotherapy; these were also compared with low-dose combinations of the two therapies. This prospective, open-label, randomized, active-controlled, multicenter study lasted 8 weeks. If patients did not meet the target blood pressure (BP) after 4 weeks of treatment with low-dose monotherapy, they were randomized to up-titration of the nifedipine GITS dose from 30 mg (N30) to 60 mg or valsartan from 80 mg to 160 mg or they were randomized to receive a low-dose combination of N30 and valsartan 80 mg for another 4 weeks. BP variability was assessed by using the SD or the %CV of the short-term BP measured at clinic. Of the 391 patients (20~70 years with stage II or higher hypertension) screened for study inclusion, 362 patients who had 3 BP measurements were enrolled. The reduction in the mean systolic/diastolic BP from baseline to week 4 was similar in both low-dose monotherapy groups with either N30 or valsartan 80 mg. BP variability (SD) was unchanged with either therapy, but the %CV was slightly increased in the N30 group. There was no significant difference in BP variability either in SD or %CV between responders and nonresponders to each monotherapy despite the significant difference in the mean BP changes. The up-titration effect of nifedipine GTS from 30 to 60 mg exhibited an additional BP reduction, but this effect was not shown in the up-titration of valsartan from 80 to 160 mg. Although the difference in BP was obvious between high-dose nifedipine GTS and valsartan, the BP variability was unchanged between the 2 drugs and was similar to the low-dose combinations. There was a low rate of adverse events in all treatment groups. In addition

  17. Spectrophotometric titration of sulfates in the presence of zirconium

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Kotova, S.S.; Molokanova, L.G.; Chekmarev, A.M.; Yagodin, G.A.

    1978-01-01

    The procedure has been proposed for express determination of sulphate ions in the presence of zirconium by spectrophotometric titration with the use of barium chloride and nitrochromazo as an indicator. The procedure is based on bonding zirconium into a more stable complex with EDTA (ethylenediaminotetraacetic acid). The presence of excess of EDTA and zirconium (4) complexonate in the solution being titrated does not affect the titration curve shape and the character of break on the curve in the equivalence point. A complete demasking of SO 4 2- is observed in the case of 1O-fold excess of EDTA with respect to zirconium (4). Statistic evaluation of the method has shown that the results of titration can be distorted by chance errors only

  18. Green chemistry volumetric titration kit for pharmaceutical formulations: Econoburette

    Directory of Open Access Journals (Sweden)

    Man Singh

    2009-08-01

    Full Text Available Stopcock SC and Spring Sp models of Econoburette (Calibrated, RTC (NR, Ministry of Small Scale Industries, Government of India, developed for semimicro volumetric titration of pharmaceutical formulations are reported. These are economized and risk free titration where pipette is replaced by an inbuilt pipette and conical flask by inbuilt bulb. A step of pipetting of stock solution by mouth is deleted. It is used to allow solution exposure to user’s body. This risk is removed and even volatile and toxic solutions are titrated with full proof safety. Econoburette minimizes use of materials and time by 90 % and prevent discharge of polluting effluent to environment. Few acid and base samples are titrated and an analysis of experimental expenditure is described in the papers.

  19. Method for linearizing the potentiometric curves of precipitation titration in nonaqueous and aqueous-organic solutions

    International Nuclear Information System (INIS)

    Bykova, L.N.; Chesnokova, O.Ya.; Orlova, M.V.

    1995-01-01

    The method for linearizing the potentiometric curves of precipitation titration is studied for its application in the determination of halide ions (Cl - , Br - , I - ) in dimethylacetamide, dimethylformamide, in which titration is complicated by additional equilibrium processes. It is found that the method of linearization permits the determination of the titrant volume at the end point of titration to high accuracy in the case of titration curves without a potential jump in the proximity of the equivalent point (5 x 10 -5 M). 3 refs., 2 figs., 3 tabs

  20. The physics of compensating calorimetry and the new CALOR89 code system

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Brau, J.E.; Bishop, B.L.

    1989-03-01

    Much of the understanding of the physics of calorimetry has come from the use of excellent radiation transport codes. A new understanding of compensating calorimetry was introduced four years ago following detailed studies with a new CALOR system. Now, the CALOR system has again been revised to reflect a better comprehension of high energy nuclear collisions by incorporating a modified high energy fragmentation model from FLUKA87. This revision will allow for the accurate analysis of calorimeters at energies of 100's of GeV. Presented in this paper is a discussion of compensating calorimetry, the new CALOR system, the revisions to HETC, and recently generated calorimeter related data on modes of energy deposition and secondary neutron production (E < 50 MeV) in infinite iron and uranium blocks. 38 refs., 5 figs., 5 tabs

  1. Study of the interactions of PAMAM-NH2 G4 dendrimer with selected natural amino acids in aqueous solutions

    International Nuclear Information System (INIS)

    Buczkowski, Adam; Palecz, Bartlomiej

    2014-01-01

    Highlights: • Calorimetric titration and dilution calorimetry show strong interactions between PAMAM-NH 2 G4 dendrimer and amino acids. • The more polar the amino acid side chain, the more exothermic the effects of the direct interactions with dendrimer. • Macromolecule of PAMAM-NH 2 G4 dendrimer can coordinate 20 to 40 molecules of amino acid. -- Abstract: The interactions of PAMAM-NH 2 G4 dendrimer with selected natural amino acids (Gly, Ala, Val, Leu, Ile, Phe, Ser, Thr, Met, Asn, Gln, Pro and Trp) in aqueous solutions were measured with the use of the techniques of calorimetric titration and dilution calorimetry. The results of calorimetric measurements show strong interactions between PAMAM-NH 2 G4 dendrimer and amino acids with polar substituents. A macromolecule of PAMAM-NH 2 G4 dendrimer can coordinate 20 to 40 molecules of amino acid

  2. Synthesized cellulose/succinic anhydride as an ion exchanger. Calorimetry of divalent cations in aqueous suspension

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Julio C.P. [Institute of Chemistry, University of Campinas, UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil); Silva Filho, Edson C. [LIMAV, Federal University of Piaui, 64049-550 Teresina, Piaui (Brazil); Santana, Sirlane A.A. [Departamento de Quimica/CCET, Universidade Federal do Maranhao, Av. dos Portugueses S/N, Campus do Bacanga, 65080-540 Sao Luiz, MA (Brazil); Airoldi, Claudio, E-mail: airoldi@iqm.unicamp.br [Institute of Chemistry, University of Campinas, UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil)

    2011-09-20

    Highlights: {yields} Synthetic route based on anhydride melting point. {yields} Cellulosic biopolymer/anhydride as ion exchanger. {yields} Calorimetry of cation exchange at solid/liquid interface. {yields} Favorable thermodynamic data of exchanging process. - Abstract: A synthetic route to a biopolymer/anhydride ion exchanger adds cellulose directly to molten succinic anhydride in a quasi solvent-free procedure. An amount of 3.07 {+-} 0.05 mmol of pendant groups incorporated onto the polymeric structure, which was characterized by elemental analysis, solid state carbon NMR, infrared, X-ray and thermogravimetry. The new polysaccharide is able to exchange cations from aqueous solution through a batchwise methodology, to obtain 2.46 {+-} 0.09 mmol g{sup -1} for divalent cobalt and nickel cations. The net thermal effects obtained from calorimetric titrations gave endothermic values of 3.81 {+-} 0.02 and 2.35 {+-} 0.01 kJ mol{sup -1}. The spontaneity of this ion-exchange process reflected in negative Gibbs energies and also a positive entropic contribution. These thermodynamic data at the solid/liquid interface suggests a favorable ion exchange process for this anchored biopolymer, for cation removal from the environment.

  3. High frequency titration in non-aqueous solvents. Application to HF and UF6

    International Nuclear Information System (INIS)

    Neveu, Claude

    1965-01-01

    In this research thesis, the author first presents the main theoretical notions regarding high frequency titration, notably by studying characteristic curves, i.e. the titration meter indication with respect to conductibility. He reports the use of this method for the study of various reactions in non-aqueous medium: reaction of AlCl 3 with pyridine in acetonitrile, of AlCl 3 with HCl in tetrachloroethane and in nitromethane. He also reports the attempt of application of this method to the titration of HF in presence of UF 6 in CCl 4 as solvent, or by using F acceptors like BF 3 , PF 5 or ClF 3 as reactants [fr

  4. New applications of corrosion measurements by titration (CMT)

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers

    1998-01-01

    . It is shown that when aluminium dissolves in alkali, CMT measurements can also be applied, but in this case requiring titration with alkali. Titration with alkali is also required in a special situation, where corrosion of nickel in an acid solution and subsequent formation of a nickel complex results...

  5. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    International Nuclear Information System (INIS)

    Asakai, Toshiaki; Hioki, Akiharu

    2011-01-01

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  6. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    Energy Technology Data Exchange (ETDEWEB)

    Asakai, Toshiaki, E-mail: t-asakai@aist.go.jp [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3-9, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563 (Japan); Hioki, Akiharu [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3-9, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563 (Japan)

    2011-03-09

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  7. The Potentiometric Titration of Filtrates from the Bachmann Process

    Science.gov (United States)

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  8. A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.

    Science.gov (United States)

    Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics

  9. ''Titration'' polymerization of monovinylacetylene

    NARCIS (Netherlands)

    Mavinkurve, A; Visser, S; vandenBroek, W; Pennings, AJ

    1996-01-01

    A polymer consisting of a saturated carbon backbone with pendent acetylenic groups was prepared from monovinylacetylene. A titration was performed between the monomer and tertiary butyllithium, its lithiating agent. The charge transfer complex formed between the solvent THF and the tertiary

  10. Coulometric titration of niobium in 1F sulfuric acid

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1975-01-01

    A coulometric titration at constant current has been devised for Nb in 1F sulfuric acid. The titration was based on the oxidation of Nb(III) to Nb(V) by Fe(III) electrogenerated at a graphite anode. Both potentiometric and amperometric end points were used. The Nb(V) was prior reduced at a mercury cathode by exhaustive electrolysis at a current density of 15 ma/mc 2 for at least 10 hr. Ta,V,Ti and a working platinum anode interfered, but the separation of the potentials of Nb(V)/Nb(III) and Ti(IV)/Ti(III) permitted the titration of first Nb and then Ti. The average error for the titration of 0.30 to 13.00 mg of niobium in 100 ml of 1F sulfuric acid was + 0.57%. (author)

  11. Calorimetry and thermodynamics of living systems

    International Nuclear Information System (INIS)

    Lamprecht, Ingolf

    2003-01-01

    Calorimetry of living systems and classical thermodynamics developed in parallel, from Lavoisier's early ice calorimeter experiments on guinea pigs, followed by Dubrunfaut's macrocalorimetric research of fermentation processes and Atwater-Rosa's whole-body calorimetry on humans and domestic animals, to the introduction of the famous Tian-Calvet instrument that found entrance into so many different fields of biology. In this work, six examples of living-system calorimetry and thermodynamics are presented. These are: (i) glycolytic oscillations far off the thermodynamic equilibrium; (ii) growth and energy balances in fermenting and respiring yeast cultures; (iii) direct and indirect calorimetric monitoring of electrically stimulated reptile metabolism; (iv) biologic and climatic factors influencing the temperature constancy and distribution in the mound of a wood ant colony as an example of a complex ecological system; (v) energetic considerations on the clustering of European honeybees in winter as a means to save energy and stored food as well as for their Japanese counterparts in defending against hornet predators; and (vi) energetic and evolutionary aspects of the mass specific entropy production rate, the so-called bound dissipation or psiu-function. The examples presented here are just a very personal selection of living systems from a broad spectrum at all levels of complexity. Common for all of them is that they were investigated calorimetrically on the background of classical and irreversible thermodynamics

  12. Particle flow calorimetry at the international linear collider

    Indian Academy of Sciences (India)

    Particle flow calorimetry at the international linear ... It is widely believed that the most promising strategy for achieving a jet ... this level of performance for two main reasons. Firstly ... (i) Tracking: For the studies presented in this paper, the track pattern ... that particles propagating outward from the interaction region will cross ...

  13. Acid-base titrations by stepwise addition of equal volumes of titrant with special reference to automatic titrations-III Presentation of a fully automatic titration apparatus and of results supporting the theories given in the preceding parts.

    Science.gov (United States)

    Pehrsson, L; Ingman, F

    1977-02-01

    This paper forms Part III of a series in which the first two parts describe methods for evaluating titrations performed by stepwise addition of equal volumes of titrant. The great advantage of these methods is that they do not require an accurate calibration of the electrode system. This property makes the methods very suitable for routine work. e.g., in automatic analysis. An apparatus for performing such titrations automatically is presented. Further, results of titrations of monoprotic acids, a diprotic acid, an ampholyte, a mixture of an acid with its conjugate base, and mixtures of two acids with a small difference between the stability constants are given. Most of these titrations cannot be evaluated by the Gran or Hofstee methods but yield results having errors of the order of 0.1% if the methods proposed in Parts I and II of this series are employed. The advantages of the method of stepwise addition of equal volumes of titrant combined with the proposed evaluation methods, in comparison with common methods such as titration to a preset pH, are that all the data are used in the evaluation, permitting a statistical treatment and giving better possibilities for tracing systematic errors.

  14. Colloid Titration--A Rapid Method for the Determination of Charged Colloid.

    Science.gov (United States)

    Ueno, Keihei; Kina, Ken'yu

    1985-01-01

    "Colloid titration" is a volumetric method for determining charged polyelectrolytes in aqueous solutions. The principle of colloid titration, reagents used in the procedure, methods of endpoint detection, preparation of reagent solutions, general procedure used, results obtained, and pH profile of colloid titration are considered. (JN)

  15. Potentiometric titration curves of aluminium salt solutions and its ...

    African Journals Online (AJOL)

    Potentiometric titration curves of aluminium salt solutions and its species conversion ... of aluminium salt solutions under the moderate slow rate of base injection. ... silicate radical, and organic acid radical on the titration curves and its critical ...

  16. Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study.

    Science.gov (United States)

    D'Onofrio, Antonio; Palmisano, Pietro; Rapacciuolo, Antonio; Ammendola, Ernesto; Calò, Leonardo; Ruocco, Antonio; Bianchi, Valter; Maresca, Fabio; Del Giorno, Giuseppe; Martino, Annamaria; Mauro, Ciro; Campari, Monica; Valsecchi, Sergio; Accogli, Michele

    2017-06-01

    Many patients fail to receive β-blockers before cardiac resynchronization therapy defibrillator (CRT-D) implantation, or receive them at a suboptimal dose, and require optimization after implantation. We assessed the effectiveness of a structured program for β-blocker titration in CRT-D patients followed up by means of conventional in-clinic visits or remote monitoring. 130 patients undergoing CRT implantation and treated according to the standard practice of the centers were included as a control group. A second group of 124 CRT-D candidates (Study Group) underwent up-titration visits every 2weeks after implantation (target dose: 10mg/day of bisoprolol or 50mg/day of carvedilol). In the Study Group, remote monitoring was undertaken in 66 patients, who received additional equipment for daily transmission of weight and blood pressure data, and scheduled titration telephone calls. In the Control Group, the maximal dose of β-blockers was being administered to 12 (9%) patients on implantation and 21 (16%) on 6-month follow-up examination (p>0.05). In the Study Group, 25 (20%) patients were receiving the maximal dose of β-blockers on implantation and 72 (58%) on follow-up examination (ptitration (versus 38% of patients followed up conventionally, ptitration increased the number of patients reaching the target dose and improved the response to the therapy. The use of remote monitoring and daily transfer of weight and blood pressure data facilitated β-blocker titration. URL: http://clinicaltrials.gov/ Identifier: NCT02173028. Copyright © 2017. Published by Elsevier B.V.

  17. A new sensor for thermometric titrations.

    Science.gov (United States)

    Najib, Fadhil M; Zewar, Sardir; Abdulla, Ahmad M

    2007-01-15

    A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32micromol of HCl and 26.4micromol of H(3)BO(3)in a final 20ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK(1)=2.18, pK(2)=7.20 and pK(3)=12.32) as well as for a very weak acid of uncertain pK values H(3)BO(3) (pK(1)=9.20, pK(2)=12.7 and pK(3)=13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.

  18. Photometric micro-determination of scandium and lanthanides by direct and successive titration using semi-xylenol orange

    International Nuclear Information System (INIS)

    Hafez, M.A.E.H.; Eman, M.E.S.M.

    1986-01-01

    The precision and accuracy attainable in direct titrations of the Sc 3+ , La 3+ or Er 3+ ion with a 0.001 M solution of the disodium salt of EDTA using semi-xylenol orange (SXO) as a metallochromic indicator were studied. Accurate results can be achieved by successive titration. The Sc 3+ ion is titrated at pH 2.4, the pH is adjusted to 5.6-5.9 by adding hexamethylenetetramine buffer solution and the La 3+ ion (or Er 3+ ion) is then titrated. A comparison of SXO and xylenol orange indicators for the successive titration of the Sc 3+ ion and lanthanum or erbium was carried out. (author)

  19. The fluorimetric titration of zirconium in the ppm-range

    International Nuclear Information System (INIS)

    Linden, W.E. von der; Boef, G. den; Ozinga, W.

    1976-01-01

    A fluorimetric titration of zirconium(IV) with EDTA is proposed. The fluorescence intensity of the zirconium-morin complex is used to indicate the end-point. More than twenty other cations were investigated and it was found that they did not interfere, neither did common anions. Mercury(II) can only be tolerated in amount not exceeding that of zirconium. Bismuth(III) interferes and hafnium(IV0 is titrated together with zirconium. The relative standard deviation of the titration of 10ml of a solution containing 1 ppm of zirconium does not exceed 1.5%

  20. Potentiometric titrations of molybdenum and vanadium in aqueous and mixed so lvents

    International Nuclear Information System (INIS)

    Das, S.K.; Dhaneshwar, R.G.

    1990-01-01

    Potentiometric titration method was developed for molybdenum, employing different electrode systems. Molybdenum(VI) is reduced to molybdenum(V) by ferrous solution in presence of phosphoric acid and then titrated with potassium dichromate. It was found that ferrous concentration should be five times more than molybdenum and phosphoric acid should be 1.0 ml for 0.1N titration and 0.5 ml for lower concentration titrations. The method is also applicable to vanadium titrations. Employing Au/SCE and Pt/SCE systems, it was observed that generally curve heights obtained for platinum electrode are higher than those for gold electrode. Also for both the electrode systems, the curve heights for vanadium titrations were found to be more than those for molybdenum. Lower limits of titrations for Au/SCE system are 0.01N for molybdenum and 0.0001N for vanadium, whereas for Pt/SCE system, the lower limits obtained were 0.01N for both molybdenum and vanadium titrations. In order to improve the sensitivities of the method, the bimetallic electrode systems Au/Pt and Pt/Au were employed. Au/Pt system was found to give better results than Pt/Au systems. Addition of organic solvent was found to have beneficial effects for titrations of 0.001N and below. Methanol was found to be a better solvent than ethanol. Molybdenum titrations, at 0.0001N level could be performed in methanol with Au/Pt system, which is to b e generally preferred than Pt/Au system. (author). 7 refs., 3 tabs

  1. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    OpenAIRE

    E. L. Artanova; E. V. Saleeva; I. M. Sokolov; Y. G. Shvarts

    2011-01-01

    Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR) were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, a...

  2. Studies on sampling and homogeneous dual readout calorimetry with meta-crystals

    CERN Document Server

    Mavromanolakis, G; Lecoq, P

    2011-01-01

    The meta-crystals concept is an approach that consists of using both undoped and properly doped heavy crystal fibers of identical material as the active medium of a calorimeter. The undoped fibers behave as Cherenkov radiators while the doped ones behave as scintillators. A dual readout calorimeter can be built with its sensitive volume composed of a mixture of both types of crystals. In addition if the calorimeter is adequately finely segmented it can also function as a particle flow calorimeter at the same time. In this way one could possibly combine the advantages of both the particle flow concept and the dual readout scheme. We discuss the approach of dual readout calorimetry with meta-crystals made of Lutetium Aluminium Garnet (LuAG). We brie fly present studies on the material development and first testbeam activities and then focus on performance expectation studies based on simulation. We discuss in more detail the results from generic systematic scannings of the design parameters of a dual readout ca...

  3. Analysis of the Purity of Cetrimide by Titrations

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Nielsen, Hans/Boye

    2006-01-01

    . Titration by perchloric acid showed a 99.69 ± 0.05 % purity of cetrimide and titration by silver nitrate showed a 99.85% ± 0.05 % purity while the traditional assay method predicted a purity of only 97.1 ± 0.4. It was found that the discrepancy could be identified as differences in selectivity during...

  4. Stabilization of the initial electrochemical potential for a metal-based potentiometric titration study of a biosorption process.

    Science.gov (United States)

    Naja, Ghinwa; Mustin, Christian; Volesky, Bohumil; Berthelin, Jacques

    2006-01-01

    An interactive metal-based potentiometric titration method has been developed using an ion selective electrode for studying the sorption of metal cations. The accuracy of this technique was verified by analyzing the metal sorption mechanism for the biomass of Rhizopus arrhizus fungus and diatomite, two dissimilar materials (organic and mineral, strong sorbent and weak sorbent) of a different order of cation exchange capacity. The problem of the initial electrochemical potential was addressed identifying the usefulness of a Na-sulfonic resin as a strong chelating agent applied before the beginning of sorption titration experiments so that the titration curves and the sorption uptake could be quantitatively compared. The resin stabilized the initial electrochemical potential to -405+/-5 mV corresponding to 2 micro gl(-1) of lead concentration in solution. The amounts of lead sorbed by R. arrhizus biomass and diatomite were 0.9 mmol g(-1) (C(e)=5.16 x 10(-2)mM) and 0.052 mmol g(-1) (C(e)=5.97 x 10(-2) mM), respectively. Lead sorption by the fungal biomass was pinpointed to at least two types of chemical active sites. The first type was distinguished by high reactivity and a low number of sites whereas the other was characterized by their higher number and lower reactivity.

  5. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    Science.gov (United States)

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  6. Indirect calorimetry: assessing animal response to heat and cold stress

    NARCIS (Netherlands)

    Gaughan, J.B.; Heetkamp, M.J.W.; Hendriks, P.

    2015-01-01

    Calorimetric thermal stress studies where indirect calorimetry is used as a tool to estimate energy expenditure have been undertaken since this technique was developed. Some examples of these studies are presented in this chapter. The measurement of gas exchange by means of an open-circuit

  7. Implementation of 'Davies and Gray/NBL Method' for potentiometric titration of uranium in the Safeguards Laboratory of CNEN by the use of a DL-67 mettler titrator

    International Nuclear Information System (INIS)

    Araujo, Radier Mario Silveira de; Barros, Pedro Dionisio de

    2005-01-01

    To meet the requirements of the Brazilian State System of Accounting for and Control of Nuclear Materials - SSAC, the Safeguards Laboratory of CNEN - LASAL has been applying the 'Davies and Gray/NBL' method for potentiometric determination of total uranium concentration in uranium samples taken during safeguards inspections at nuclear facilities since 1984, using a Radiometer ETS 822 titrator. In order to improve the analytical capability and the procedures related to the titration methodology, the same method was also implemented by using a METTLER DL - 67 titrator. This equipment is microprocessor - controlled and can be connected to additional devices such as printers, analytical balances, etc. It also provides accurate and reproducible results for end-point titrations, providing analytical performance according to the current international safeguards requirements. The implementation of the method in such equipment included the addition of analytical data as well as the improvement of the equipment parameters for uranium determination. Parameters like predispensing volume; titrant data and end-point value were studied. Some uranium samples (solids and solutions) were used during the initial tests with the titrator. A solution of pure uranyl nitrate was used as reference sample for this paper. From this, aliquots were analyzed in both Radiometer ETS-822 and METTLER DL-67. Results obtained from each equipment were compared with the reference value of the sample. The comparison showed that results from METTLER DL-67 meets the precision and accuracy requirements for this kind of analysis and led to the conclusion that the performance of this titrator is adequate for the determination of total uranium content in samples of nuclear materials for safeguards purposes. (author)

  8. Thermometric titrations of amines with nitrosyl perchlorate in acetonitrile solvent.

    Science.gov (United States)

    Gündüz, T; Kiliç, E; Cakirer, O

    1996-05-01

    Thirteen aliphatic and four aromatic amines, namely diethylamine, triethylamine, n-propylamine, di-n-propylamine, tri-n-butylamine, isopropylamine, di-isopropylamine, n-butylamine, di-n-butylamine, tri-n-butylamine, isobutylamine, sec-butylamine, tert-butylamine, aniline, N,N-dimethylaniline, 2-nitroaniline and 4-nitroaniline were titrated thermometrically with nitrosyl perchlorate in acetonitrile solvent. All the aliphatic amines gave very well-shaped thermometric titration curves. The calculated recovery values of the amines were very good. In comparison, the aromatic amines, aniline and N,N-dimethylaniline gave rather well-shaped titration curves, but the recovery values were fairly low. 2-Nitro- and 4-nitro anilines gave no thermometric response at all. The heats of reaction of the amines with nitrosyl perchlorate are rather high. However, the average heat of reaction of the aromatic amines is approximately two-thirds that of the average heat of the aliphatic amines. To support this method all the amines were also titrated potentiometrically and very similar results to those obtained with the thermometric method are seen. The nitrosyl ion is a Lewis acid, strong enough to titrate quantitatively aliphatic amines in acetonitrile solvent, but not strong enough to titrate aromatic amines at the required level in the same solvent.

  9. Gran method for end point anticipation in monosegmented flow titration

    Directory of Open Access Journals (Sweden)

    Aquino Emerson V

    2004-01-01

    Full Text Available An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second derivative procedure. In this case, additional volumes of titrant are added until the vicinity of the end point and three points before and after the stoichiometric point are used for end point calculation. The performance of the system was assessed by the determination of chloride in isotonic beverages and parenteral solutions. The system employs a tubular Ag2S/AgCl indicator electrode. A typical titration, performed according to the IUPAC definition, requires only 60 mL of sample and about the same volume of titrant (AgNO3 solution. A complete titration can be carried out in 1 - 5 min. The accuracy and precision (relative standard deviation of ten replicates are 2% and 1% for the Gran and 1% and 0.5% for the Gran/derivative end point determination procedures, respectively. The proposed system reduces the time to perform a titration, ensuring low sample and reagent consumption, and full automatic sampling and titrant addition in a calibration-free titration protocol.

  10. Amperometric titration of thorium and some lanthanoids in acetic-acid medium using two indicator electrodes

    International Nuclear Information System (INIS)

    Khadeev, V.A.; Gevorgyan, A.M.; Talipov, Sh.T.; Kostylev, V.S.

    1979-01-01

    The votammetric behaviour of nitriletrimethylphosphonic acid (NTMP) in the medium of anhydrous acetic acid with different backgrounds in the anode region of polarization of a platinum microdisk electrode, is studied. The optimal conditions are found for the amperometric titration with two indicator electrodes of thorium and same lanthanides by a NTMP solution in anhydrous acetic medium. The influence of foreign anions and cations on the results of titration by the NTPM solution in anhydrous acetic acid is studied. The selectivity of titration in anhydrous medium is higher than in aqueous

  11. Biophysical and electrochemical studies of protein-nucleic acid interactions

    Czech Academy of Sciences Publication Activity Database

    Bowater, R. P.; Cobb, A:M.; Pivoňková, Hana; Havran, Luděk; Fojta, Miroslav

    2015-01-01

    Roč. 146, č. 5 (2015), s. 723-739 ISSN 0026-9247 R&D Projects: GA ČR(CZ) GBP206/12/G151; GA ČR(CZ) GAP301/11/2076 Institutional support: RVO:68081707 Keywords : ISOTHERMAL TITRATION CALORIMETRY * OSMIUM-TETROXIDE COMPLEXES * SURFACE-PLASMON RESONANCE Subject RIV: BO - Biophysics Impact factor: 1.131, year: 2015

  12. A study of salt effects on the complexation between beta-cyclodextrins and bile salts based on the Hofmeister series

    DEFF Research Database (Denmark)

    Holm, Rene; Schonbeck, Christian; Somprasirt, Pitchayanun

    2014-01-01

    bound drug molecules. The influence of Hofmeister ions on the binding constants of complexes between CDs (β-CD and hydroxypropylated β-CD) and bile salts (glycocholate and glycochenodeoxycholate) were examined by isothermal titration calorimetry. The chaotropic anions tended to weaken these inclusion...

  13. Thermometric Titration for Rapid Determination of Trace Water in Jet Fuel

    Directory of Open Access Journals (Sweden)

    Jian-Qiang Hu

    2017-01-01

    Full Text Available Water content in jet fuels is detected by thermometric titration (TMT, and the optimal detected system is 2,2-dimethoxypropane as titrant, cyclohexane and isopropanol as titration solvents, and methanesulfonic acid as catalyst in this method. The amounts of oil, concentration and delivery rate of titrant, volumes, and the reliability and accuracy of thermometric titration were emphasized. The results show that the accuracy, validity, and reliability of TMT are excellent by different indicated spiked water contents. The obtained results between TMT and Karl Fischer titration have been proven to be in accord. But, the duration of titration merely spends 3–5 min in the whole process, greatly shortening the detected time. Therefore, rapid and accurate determination of trace water in a jet fuel can be realized by TMT.

  14. Filtrates & Residues: Olfactory Titration.

    Science.gov (United States)

    Wood, John T.; Eddy, Roberta M.

    1996-01-01

    Presents an experiment that uses a unique acid-base indicator--the odor of raw onion--to indicate the end point of the titration of sodium hydroxide with hydrochloric acid. Allows the student to detect the completion of the neutralization reaction by olfaction rather than sight. (JRH)

  15. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    Directory of Open Access Journals (Sweden)

    Lorentz JÄNTSCHI

    2002-12-01

    Full Text Available The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titrations/v1.1/ The method allows expressing the value of pH in any point of titration process and permits to observe the equivalence point of titration.

  16. A reliable and feasible qPCR strategy for titrating AAV vectors.

    Science.gov (United States)

    Wang, Feng; Cui, Xiuling; Wang, Mingxi; Xiao, Weidong; Xu, Ruian

    2013-07-05

    Previous studies have revealed that traditional real-time quantitative PCR (qPCR) underestimates adeno-associated virus (AAV) titer. Because the inverted terminal repeat (ITR) exists in all AAV vectors, the only remaining element from the wild genome could form special configurations to interfere with qPCR titration. To solve this problem, a modified and universal qPCR method was tested and established. In this work, there was a great variation in titration of ssAAV2-EGFP (Enhanced Green Fluorescence Protein) and scAAV2-EGFP genome by traditional qPCR. For ssAAV2-EGFP, the highest titer was found by using the targeting EGFP primers and the lowest titer was measured by those targeting bovine growth hormone polyA element (pBGH) primers. Experimental data were reverse for ssAAV2-EGFP and scAAV2-EGFP. Here we report an improved and universal SmaI qPCR method, based on cleaving all ITRs in AAV2 genome by SmaI with several advantages: (1) impact of all ITRs in ssAAV2 and scAAV2 was dismissed; (2) titers increased remarkably, up to 7-fold, especially for scAAV2; (3) the variation of titers was reduced when different primers were applied. A similar phenomenon was also observed in other ssAAV2 and scAAV2 products when the range of titration was at 3×107 to 7×109 V.G/µl in this study. This modified qPCR strategy can increase rAAV' titer and reduce titration variance, possibly become a universal method for titrating AAV vectors.

  17. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    Science.gov (United States)

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  18. Amperometric, Bipotentiometric, and Coulometric Titration.

    Science.gov (United States)

    Stock, John T.

    1980-01-01

    Discusses recent review articles in various kinds of titration. Also discusses new research in apparatus and methodology, acid-base reactions, precipitation and complexing reactions, oxidation-reduction reactions, and nomenclature. Cites 338 references. (CS)

  19. The use of calorimetry for plutonium assay

    International Nuclear Information System (INIS)

    Mason, J.A.

    1982-12-01

    Calorimetry is a technique for measuring the thermal power of heat-producing substances. The technique may be applied to the measurement of plutonium-bearing materials which evolve heat as a result of alpha and beta decay. A calorimetric measurement of the thermal power of a plutonium sample, combined with a knowledge or measurement of the plutonium isotopic mass ratios of the sample provides a convenient and accurate, non-destructive measure of the total plutonium mass of the sample. The present report provides a description, and an assessment of the calorimetry technique applied to the assay of plutonium-bearing materials. Types and characteristics of plutonium calorimeters are considered, as well as calibration and operating procedures. The instrumentation used with plutonium calorimeters is described and the use of computer control for calorimeter automation is discussed. A critical review and assessment of plutonium calorimetry literature since 1970 is presented. Both fuel element and plutonium-bearing material calorimeters are considered. The different types of plutonium calorimeters are evaluated and their relative merits are discussed. A combined calorimeter and gamma-ray measurement assay system is considered. The design principles of plutonium assay calorimeters are considered. An automatic, computer-based calorimeter control system is proposed in conjunction with a general plutonium assay calorimeter design. (author)

  20. New crystals for dual-readout calorimetry

    Czech Academy of Sciences Publication Activity Database

    Akchurin, N.; Bedeschi, F.; Cardini, A.; Carosi, R.; Ciapetti, G.; Ferrari, R.; Franchino, S.; Fraternali, M.; Gaudio, G.; Hauptman, J.; Incagli, M.; Korzhik, M.; Lacava, F.; La Rotonda, L.; Livan, M.; Meoni, E.; Nikl, Martin; Pinci, D.; Policicchio, A.; Popescu, S.; Scuri, F.; Sill, A.; Vandelli, W.; Vedda, A.; Venturelli, T.; Voena, C.; Volobouev, I.; Wigmans, R.

    2009-01-01

    Roč. 604, č. 3 (2009), s. 512-526 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10100521 Keywords : calorimetry * Cherenkov light * high-Z scintillating crystals Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.317, year: 2009

  1. Interaction of molybdenum (6) with potassium benzyldithiocarbaminate during amperometric titration

    International Nuclear Information System (INIS)

    Galushko, S.V.; Usatenko, Yu.I.

    1975-01-01

    The paper is an amperometric study of the mechanism of interaction between molybdenum (VI) and potassium benzyl dithiocarbamate [BDTC] which was based on the use of voltamperometry, electron paramagnetic resonance, infrared spectroscopy, potentiometry and elemental analysis. In amperometric titration Mo(VI) with BDTC (pH 4-2) forms a red compound of low solubility. In more acidic media the intensity of coloration is increased and a violet hue develops. On the basis of the data obtained it is concluded that in the amperometric titration of Mo(VI) with potassium BDTC there is first formation of a Mo(VI) compound, which subsequently acquires a red colour as a result of the reduction of Mo(VI) to Mo(V). It was also established that the degree of reduction is small where titration is carried out in the range pH 4.8-0.1. Quantitative determination of Mo is performed most effectively in slightly acidic media. Mo reacts with potassium BDTC in a ratio of 1:2. (E.P.)

  2. Chemical calibration of Isothermal Titration Calorimeters: An evaluation of the dilution of propan-1-ol into water as a test reaction using different calorimeters, concentrations, and temperatures

    International Nuclear Information System (INIS)

    Adão, Regina; Bai, Guangyue; Loh, Watson; Bastos, Margarida

    2012-01-01

    Highlights: ► We address the importance of test reactions in Isothermal Titration Calorimetry. ► We re-evaluate a test reaction and provide a new value for it at 308.15 K. ► Different concentrations are tested to account for instrument sensitivity. ► We compare the performance of two very sensitive calorimeters of different design. ► We suggest appropriate experimental conditions for the use of this test reaction. - Abstract: The use of a good chemical calibration or test reaction in Isothermal Titration Calorimetry is crucial for getting reliable enthalpy values that can be compared across different laboratories. Indeed most titration calorimeters are used to measure both equilibrium constants and molar enthalpies of reaction. But a necessary prerequisite for such measurements is to first perform the enthalpy measurement accurately and precisely. The values of the equilibrium constant(s) are then calculated by regression from an appropriate model. As such, we found it timely to extensively test a previously proposed test reaction, the dilution of propan-1-ol into water, using two calorimeters of different design (heat conduction and power compensation calorimeters) and sensitivity. Experiments were performed at 298.15 K for the previously suggested 10% mass fraction propan-1-ol solution, as well as for the lower concentrations of 5% and 2% mass fractions. Due to our capacity to use insertion heaters with one of the used calorimeters, which allows for very accurate calibration constants to be obtained, we also determined a value for the enthalpy of dilution of 10% mass fraction solution at 308.15 K, previously not available, and closer to the temperatures commonly used in titration experiments involving biological samples. The observed change in the enthalpy of dilution was found to decrease in absolute value, but to an extent that did not justify the determination of new values for the less concentrated solutions. The values obtained with the two

  3. Interaction Between Some Monosaccharides and Aspartic Acid in Dilute Aqueous Solutions

    OpenAIRE

    Kulikova, Galina A.; Parfenyuk, Elena V.

    2007-01-01

    Interaction between aspartic acid and d-glucose, d-galactose, and d-fructose has been studied by isothermal titration calorimetry, calorimetry of dissolution, and densimetry. It has been found that d-glucose and d-fructose form thermodynamically stable associates with aspartic acid, in contrast to d-galactose. The selectivity in the interaction of aspartic acid with monosaccharides is affected by their stereochemical structures.

  4. Evaluation of the amorphous content of lactose by solution calorimetry and Raman spectroscopy.

    Science.gov (United States)

    Katainen, Erja; Niemelä, Pentti; Harjunen, Päivi; Suhonen, Janne; Järvinen, Kristiina

    2005-11-15

    Solution calorimetry can be used to determine the amorphous content of a compound when the solubility and dissolution rate of the compound in the chosen solvent are reasonably high. Sometimes, it can be difficult find a solvent in which a sample is freely soluble. The present study evaluated the use of solution calorimetry for the assessment of the amorphous content of a sample that is poorly soluble in a solvent. Physical mixtures of lactose and spray-dried lactose samples (the amorphous content varied from 0 to 100%) were analyzed by a solution calorimeter and the results were compared with Raman spectroscopy determinations. The heat of solvation of the samples was determined by solution calorimetry in organic solvents MeOH, EtOH, ACN, THF, acetone (400mg sample/100ml solvent). Lactose is virtually insoluble in ACN, THF and acetone and very slightly soluble in EtOH and MeOH. The amorphous content of the samples could not be determined by solution calorimetry in EtOH, ACN, THF or acetone. However, an excellent correlation was observed between the heat of solvation and the amorphous content of the samples in MeOH. Furthermore, the heat of solvation values of the samples in MeOH showed a linear correlation with the Raman quantifications. Therefore, our results demonstrate that solution calorimetry may represent a rapid and simple method for determining the amorphous content also in samples that are not freely soluble in the solvent.

  5. Patient-led versus physician-led titration of insulin glargine in patients with uncontrolled type 2 diabetes: a randomized multinational ATLAS study.

    Science.gov (United States)

    Garg, Satish K; Admane, Karim; Freemantle, Nick; Odawara, Masato; Pan, Chang-Yu; Misra, Anoop; Jarek-Martynowa, Iwona R; Abbas-Raza, Syed; Mirasol, Roberto C; Perfetti, Riccardo

    2015-02-01

    Self-adjustment of insulin dose is commonly practiced in Western patients with type 2 diabetes but is usually not performed in Asian patients. This multinational, 24-week, randomized study compared patient-led with physician-led titration of once-daily insulin glargine in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering agents. Patient-led (n = 275) or physician-led (n = 277) subjects followed the same dose-titration algorithm guided by self-monitored fasting blood glucose (FBG; target, 110 mg/dL [6.1 mmol/L]). The primary endpoint was change in mean glycated hemoglobin (HbA1c) at week 24 in the patient-led versus physician-led titration groups. Patient-led titration resulted in a significantly higher drop in HbA1c value at 24 weeks when compared with physician-led titration (-1.40% vs. -1.25%; mean difference, -0.15; 95% confidence interval, -0.29 to 0.00; P = .043). Mean decrease in FBG was greatest in the patient-led group (-2.85 mmol/L vs. -2.48 mmol/L; P = .001). The improvements in HbA1c and FBG were consistent across countries, with similar improvements in treatment satisfaction in both groups. Mean daily insulin dose was higher in the patient-led group (28.9 units vs. 22.2 units; Ptitration achieved near-target blood glucose levels in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering drugs, demonstrating that Asian patients can self-uptitrate insulin dose effectively when guided.

  6. The role of titration schedule of topiramate for the development of depression in patients with epilepsy.

    Science.gov (United States)

    Mula, Marco; Hesdorffer, Dale C; Trimble, Michael; Sander, Josemir W

    2009-05-01

    To determine whether a fast titration schedule of topiramate (TPM) has different effects on the occurrence of depression, in relation to other risk factors for TPM-induced depression, including history of depression (HxDEP), febrile seizures (FS), and hippocampal sclerosis (HS). Using data from a large case registry of patients prescribed TPM, two models were constructed: Model 1 examined the independent effect of rapid TPM titration after separate adjustment for FS, HxDEP, and HS. Model 2 examined effect of the cooccurrence of rapid titration on the development of depression with each of these risk factors. A total of 423 patients were included (51.8% females), mean age (SD) 35.5 (11.8) years, mean duration of epilepsy of 22.2 (11.5) years. Forty-four patients (10.4%) developed depression during TPM therapy. A rapid TPM titration was associated with 5-fold increased risk of depression that increased to 12.7-fold in the presence of both FS and rapid TPM titration, 23.3-fold in the presence of both HxDEP and rapid TPM titration, and 7.6-fold in the presence of both HS and rapid TPM titration schedule. Our study suggests that a rapid titration schedule is associated with an increased risk of developing depression during TPM therapy. HxDEP and FS are major contraindications to the use of a rapid titration, with a 23.3-fold and 12.7 fold increased risk, respectively.

  7. Measuring titratable alkalinity by single versus double endpoint titration: An evaluation in two cyprinodont species and implications for characterizing net H+ flux in aquatic organisms.

    Science.gov (United States)

    Brix, Kevin V; Wood, Chris M; Grosell, Martin

    2013-01-01

    In this study, Na(+) uptake and acid-base balance in the euryhaline pupfish Cyprinodon variegatus variegatus were characterized when fish were exposed to pH 4.5 freshwater (7mM Na(+)). Similar to the related cyprinodont, Fundulus heteroclitus, Na(+) uptake was significantly inhibited when exposed to low pH water. However, it initially appeared that C. v. variegatus increased apparent net acid excretion at low pH relative to circumneutral pH. This result is opposite to previous observations for F. heteroclitus under similar conditions where fish were observed to switch from apparent net H(+) excretion at circumneutral pH to apparent net H(+) uptake at low pH. Further investigation revealed disparate observations between these studies were the result of using double endpoint titrations to measure titratable alkalinity fluxes in the current study, while the earlier study utilized single endpoint titrations to measure these fluxes (i.e.,. Cyprinodon acid-base transport is qualitatively similar to Fundulus when characterized using single endpoint titrations). This led to a comparative investigation of these two methods. We hypothesized that either the single endpoint methodology was being influenced by a change in the buffer capacity of the water (e.g., mucus being released by the fish) at low pH, or the double endpoint methodology was not properly accounting for ammonia flux by the fish. A series of follow-up experiments indicated that buffer capacity of the water did not change significantly, that excretion of protein (a surrogate for mucus) was actually reduced at low pH, and that the double endpoint methodology does not properly account for NH(3) excretion by fish under low pH conditions. As a result, it overestimates net H(+) excretion during low pH exposure. After applying the maximum possible correction for this error (i.e., assuming that all ammonia is excreted as NH(3)), the double endpoint methodology indicates that net H(+) transport was reduced to

  8. When acid-base titrations are carried out in unusual conditions

    Directory of Open Access Journals (Sweden)

    Domenico De Marco

    2012-12-01

    Full Text Available Uncommon aspects in acid-base titrations are presented, which occur in titrations between both mono- and/or poly-functional acid and bases but are rarely introduced in ordinary analytical chemistry courses.

  9. Plutonium titration by controlled potential coulometry; Dosage du plutonium par coulometrie a potentiel impose

    Energy Technology Data Exchange (ETDEWEB)

    Leguay, N.

    2011-07-01

    The LAMMAN (Nuclear Materials Metrology Laboratory) is the support laboratory of the CETAMA (Analytical Method Committee), whose two main activities are developing analytic methods, and making and characterizing reference materials. The LAMMAN chose to develop the controlled potential coulometry because it is a very accurate analytical technique which allows the connection between the quantity of element electrolysed to the quantity of electricity measured thanks to the Faraday's law: it does not require the use of a chemical standard. This method was first used for the plutonium titration and was developed in the Materials Analysis and Metrology Laboratory (LAMM), for upgrading its performances and developing it to the titration of other actinides. The equipment and the material used were developed to allow the work in confined atmosphere (in a glove box), with all the restrictions involved. Plutonium standard solutions are used to qualify the method, and in particular to do titrations with an uncertainty better than 0.1 %. The present study allowed making a bibliographic research about controlled potential coulometry applied to the actinides (plutonium, uranium, neptunium, americium and curium). A full procedure was written to set all the steps of plutonium titration, from the preparation of samples to equipments storage. A method validation was done to check the full procedure, and the experimental conditions: working range, uncertainty, performance... Coulometric titration of the plutonium from pure solution (without interfering elements) was developed to the coulometric titration of the plutonium in presence of uranium, which allows to do accurate analyses for the analyses of some parts of the reprocessing of the spent nuclear fuel. The possibility of developing this method to other actinides than plutonium was highlighted thanks to voltammetric studies, like the coulometric titration of uranium with a working carbon electrode in sulphuric medium. (author)

  10. Potentiometric and spectrophotometric titration study of interaction of tungstovanadophosphoric heteropolyacids with sodium hydroxide

    International Nuclear Information System (INIS)

    Borkoyakov, S.A.; Fisun, L.A.

    1988-01-01

    The methods of potentiometric and spectrophotometric titration are used to study H s+n PW 12-n V n O 40 (n=1,2) (P-W-V HPA) decomposition by sodium hydroxide. It is shown that at the first stage of heteropolyanion interaction with alkali (pH) > 4 P-W-V HPA structural reconstruction takes place. It is accompanied by the formation of complexes with a higher content of vanadium atoms stable at pH 4-7/ P-W-V HPA decomposition to initial salts occurs at pH > 8

  11. Spectrophotometric titrations: Application to the determination of some elements in uranium solutions

    International Nuclear Information System (INIS)

    L'Her, M.

    1967-01-01

    The aim of this work is the application of spectrophotometric titrations to the analysis of uranium-containing solutions. We have been led to examine the general principles involved in these titrations, and we give a brief outline of these principles. In the first part we deal therefore with spectrophotometric titrations from a general point of view, examining their fundamental principle, their practical execution as well as the various possibilities of the method. The advantage of the titration are examined, in particular that of lending itself simultaneous determination of two species. The possibility of applying these spectrophotometric titrations to the analysis of uranium-containing solutions is the subject of the second part of this report: the dosage of a few species in uranium (VI) solutions is described. To this second part is added an experimental appendix consisting of a description of the apparatus, as well as of the operational techniques used for certain titrations, in particular those involving solutions containing uranium. (author) [fr

  12. Fluorescence-Based Comparative Binding Studies of the Supramolecular Host Properties of PAMAM Dendrimers Using Anilinonaphthalene Sulfonates: Unusual Host-Dependent Fluorescence Titration Behavior

    Directory of Open Access Journals (Sweden)

    Natasa Stojanovic

    2010-04-01

    Full Text Available This work describes the fluorescence enhancement of the anilinonaphthalene sulfonate probes 1,8-ANS, 2,6-ANS, and 2,6-TNS via complexation with PAMAM dendrimer hosts of Generation 4, 5 and 6. The use of this set of three very closely related probes allows for comparative binding studies, with specific pairs of probes differing only in shape (1,8-ANS and 2,6-ANS, or in the presence of a methyl substituent (2,6-TNS vs. 2,6-ANS. The fluorescence of all three probes was significantly enhanced upon binding with PAMAM dendrimers, however in all cases except one, a very unusual spike was consistently observed in the host fluorescence titration plots (fluorescence enhancement vs. host concentration at low dendrimer concentration. This unprecedented fluorescence titration curve shape makes fitting the data to a simple model such as 1:1 or 2:1 host: guest complexation very difficult; thus only qualitative comparisons of the relative binding of the three guests could be made based on host titrations. In the case of G4 and G5 dendrimers, the order of binding strength was qualitatively determined to be 1,8-ANS < 2,6-ANS indicating that the more streamlined 2,6-substituted probes are a better match for the dendrimer cavity shape than the bulkier 1,8-substituted probe. This order of binding strength was also indicated by double fluorometric titration experiments, involving both host and guest titrations. Further double fluorometric titration experiments on 2,6-ANS in G4 dendrimer revealed a host concentration-dependent change in the nature of the host: guest complexation, with multiple guests complexed per host molecule at very low host concentrations, but less than one guest per host at higher concentrations.

  13. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    Directory of Open Access Journals (Sweden)

    E. L. Artanova

    2011-01-01

    Full Text Available Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, amiodarone therapy were considered among clinical characteristics. Results. Adjusted warfarin dose was significantly higher in obesity , and it was lower in case of experienced myocardial infarction. The INR highest levels and maximal amplitudes of its fluctuations were observed in patients with thyroid gland nodes and smokers. Period of warfarin dose titration was longer in patients treated with amiodarone. Conclusion. Warfarin dose titration in patients with atrial fibrillation depends on the presence of myocardial infarction, obesity , thyroid nodular changes, smoking and amiodarone treatment.

  14. Polymer-surfactant interactions studied by titration microcalorimetry : Influence of polymer hydrophobicity, electrostatic forces, and surfactant aggregational state

    NARCIS (Netherlands)

    Kevelam, J; van Breemen, J.F.L.; Blokzijl, W.; Engberts, J.B.F.N.

    1996-01-01

    Isothermal titration microcalorimetry has been applied to investigate the interactions between hydrophobically-modified water-soluble polymers and surfactants. The following polymers were used in this study: poly(sodium acrylate-co-n-alkyl methacrylate) (A), where n-alkyl = C9H19, C12H25, and C18H37

  15. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study

    NARCIS (Netherlands)

    Aten, J.J.; Oudega, M.L.; van Exel, E.; Stek, M.L.; van Waarde, J.A.

    2015-01-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment

  16. Phase behavior and micellar properties of carboxylic acid end group modified pluronic surfactants

    NARCIS (Netherlands)

    Custers, J.P.A.; Broeke, van den L.J.P.; Keurentjes, J.T.F.

    2007-01-01

    The micellar behavior of three different carboxylic acid end standing (CAE) surfactants has been characterized using conductometry, differential scanning calorimetry, isothermal titration calorimetry, and dynamic light scattering. The CAE surfactants are modified high molecular weight Pluronic

  17. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    International Nuclear Information System (INIS)

    Janot, N.; Benedetti, M. F.; Janot, N.; Reiller, P. E.; Korshin, G. V.

    2010-01-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM (≥1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  18. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Janot, N.; Benedetti, M. F. [Univ Paris Diderot, Lab Geochim Eaux, UMR CNRS 7154, IPGP, F-75025 Paris 13 (France); Janot, N.; Reiller, P. E. [CE Saclay, CEA DEN DANS DPC SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Korshin, G. V. [Univ Washington, Dept Civil and Environm Engn, Seattle, WA 98195 (United States)

    2010-07-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM ({>=}1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  19. A single-beam titration method for the quantification of open-path Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Sung, Lung-Yu; Lu, Chia-Jung

    2014-01-01

    This study introduced a quantitative method that can be used to measure the concentration of analytes directly from a single-beam spectrum of open-path Fourier Transform Infrared Spectroscopy (OP-FTIR). The peak shapes of the analytes in a single-beam spectrum were gradually canceled (i.e., “titrated”) by dividing an aliquot of a standard transmittance spectrum with a known concentration, and the sum of the squared differential synthetic spectrum was calculated as an indicator for the end point of this titration. The quantity of a standard transmittance spectrum that is needed to reach the end point can be used to calculate the concentrations of the analytes. A NIST traceable gas standard containing six known compounds was used to compare the quantitative accuracy of both this titration method and that of a classic least square (CLS) using a closed-cell FTIR spectrum. The continuous FTIR analysis of industrial exhausting stack showed that concentration trends were consistent between the CLS and titration methods. The titration method allowed the quantification to be performed without the need of a clean single-beam background spectrum, which was beneficial for the field measurement of OP-FTIR. Persistent constituents of the atmosphere, such as NH 3 , CH 4 and CO, were successfully quantified using the single-beam titration method with OP-FTIR data that is normally inaccurate when using the CLS method due to the lack of a suitable background spectrum. Also, the synthetic spectrum at the titration end point contained virtually no peaks of analytes, but it did contain the remaining information needed to provide an alternative means of obtaining an ideal single-beam background for OP-FTIR. - Highlights: • Establish single beam titration quantification method for OP-FTIR. • Define the indicator for the end-point of spectrum titration. • An ideal background spectrum can be obtained using single beam titration. • Compare the quantification between titration

  20. Benefit of slow titration of paroxetine to treat depression in the elderly.

    Science.gov (United States)

    Olgiati, Paolo; Bajo, Emanuele; Serretti, Alessandro

    2014-11-01

    Paroxetine is commonly used to treat depression in the elderly; however, titration issues have been raised. Rapid titration may lead to increased anxiety and early dropout. The aim of this cost-utility analysis was to compare the potential benefit of standard (10 mg the first day) versus slow titration (2.5 mg gradually increased). Clinical analysis was based on a naturalistic trial integrated with a decision-analytic model representing second treatments for those who initially did not respond and for dropout cases. Treatment setting was a public outpatient center for mental disorders in Italy. Service use data were estimated from best practice guidelines, whereas costs (Euros; 2012) were retrieved from Italian official sources. Slow titration approach produced 0.031 more quality-adjusted life years (remission rate: 57% vs 44% in standard titration group) at an incremental cost of €5.53 (generic paroxetine) and €54.54 (brand paroxetine syrup). Incremental cost-effectiveness ratio (ICER) values were €159 and €1768, respectively, in favor of slow titration approach. Cost-effectiveness threshold, defined as ICER titration of paroxetine in older depressed patients. However, these findings, in part based on simulated data, need to be replicated in clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Graphical evaluation of complexometric titration curves.

    Science.gov (United States)

    Guinon, J L

    1985-04-01

    A graphical method, based on logarithmic concentration diagrams, for construction, without any calculations, of complexometric titration curves is examined. The titration curves obtained for different kinds of unidentate, bidentate and quadridentate ligands clearly show why only chelating ligands are usually used in titrimetric analysis. The method has also been applied to two practical cases where unidentate ligands are used: (a) the complexometric determination of mercury(II) with halides and (b) the determination of cyanide with silver, which involves both a complexation and a precipitation system; for this purpose construction of the diagrams for the HgCl(2)/HgCl(+)/Hg(2+) and Ag(CN)(2)(-)/AgCN/CN(-) systems is considered in detail.

  2. Determination of uranium by direct titration with dipicolinic acid

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1984-01-01

    Direct titration of uranium with dipicolinic acid, in the presence of Arsenazo I, is a simple, precise, and accurate method for uranium determination. The method is particularly attractive because it can be totally automated. Detecting the end point (color change from blue to pink) depends on the concentration range. For the Micro Method (1 to 20 ppM U in the solution titrated), the gradual color change is monitored spectrophotometrically. For the Macro Method (20 to 300 ppM), the end point is determined either visually or spectrophotometrically. The spectrophotometric end point is computed by fitting the titration curve. The relative standard deviation is +-1 to 3% for the Micro Method and +-0.3% for the Macro Method

  3. Calorimetric approach of ions adsorption; Approche calorimetrique de l'absorption d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Lantenois, S. [Montpellier-2 Univ., 34 (France)

    2006-07-01

    The aim of this work is to obtain experimentally thermodynamic data of ions adsorption by micro-calorimetry. Different thermal effects can be measured on different silicon oxides (Spherosil or SBA-15) and with different cations (Cd{sup 2+} and Pb{sup 2+}). The solids are studied in the same experimental conditions in a NaNO{sub 3} solution (10{sup -1} M) at pH of 5 or 7 (adjusted by addition of NaOH or HNO{sub 3}) in terms of the hydrolysis pH of the adsorbed cation. The aqueous solution is a NaNO{sub 3} (10{sup -1} M) solution containing Cd(NO{sub 3}){sub 2} (pH 7.0) or Pb(NO{sub 3}){sub 2} (pH 5.0) at different concentrations (between 5*10{sup -4} and 10{sup -2} M). The thermal effect due to the addition of this solution is measured by titration calorimetry and by flux calorimetry. The complementarity of these two techniques is developed during this study where the titration calorimetry has been used for studying the thermal effects at low concentrations in metallic cations. The flux calorimetry has allowed to analyze systems at stronger concentration in metallic cations and to study the desorption of these cations. This study shows that the thermal effect bound to the surfaces reactivity is composed of a combination of factors. Factors such as surface charges density (pH and protonation deprotonation reactions), the samples preparation (previous calcination) or the capacity of cations to hydrolyze can be revealed by micro-calorimetry. (O.M.)

  4. A new titration system of a novel split-type superconducting magnet NMR spectrometer.

    Science.gov (United States)

    Kitagawa, Isao; Tanaka, Hideki; Okada, Michiya; Kitaguchi, Hitoshi; Kohzuma, Takamitsu

    2008-12-01

    A new titration system for studying protein-ligand interactions has been developed. In this system, the sample solution is circulated in the route formed by an access path in a split superconducting magnet to maintain a constant protein concentration during the titration experiments. A concentration-control procedure for the ligand/protein ratio is devised, and the ligand/protein ratio is well controlled by this apparatus.

  5. A Brief Survey of Patients' First Impression after CPAP Titration Predicts Future CPAP Adherence: A Pilot Study

    Science.gov (United States)

    Balachandran, Jay S.; Yu, Xiaohong; Wroblewski, Kristen; Mokhlesi, Babak

    2013-01-01

    Background: CPAP adherence patterns are often established very early in the course of therapy. Our objective was to quantify patients' perception of CPAP therapy using a 6-item questionnaire administered in the morning following CPAP titration. We hypothesized that questionnaire responses would independently predict CPAP adherence during the first 30 days of therapy. Methods: We retrospectively reviewed the CPAP perception questionnaires of 403 CPAP-naïve adults who underwent in-laboratory titration and who had daily CPAP adherence data available for the first 30 days of therapy. Responses to the CPAP perception questionnaire were analyzed for their association with mean CPAP adherence and with changes in daily CPAP adherence over 30 days. Results: Patients were aged 52 ± 14 years, 53% were women, 54% were African American, the mean body mass index (BMI) was 36.3 ± 9.1 kg/m2, and most patients had moderate-severe OSA. Four of 6 items from the CPAP perception questionnaire— regarding difficulty tolerating CPAP, discomfort with CPAP pressure, likelihood of wearing CPAP, and perceived health benefit—were significantly correlated with mean 30-day CPAP adherence, and a composite score from these 4 questions was found to be internally consistent. Stepwise linear regression modeling demonstrated that 3 variables were significant and independent predictors of reduced mean CPAP adherence: worse score on the 4-item questionnaire, African American race, and non-sleep specialist ordering polysomnogram and CPAP therapy. Furthermore, a worse score on the 4-item CPAP perception questionnaire was consistently associated with decreased mean daily CPAP adherence over the first 30 days of therapy. Conclusions: In this pilot study, responses to a 4-item CPAP perception questionnaire administered to patients immediately following CPAP titration independently predicted mean CPAP adherence during the first 30 days. Further prospective validation of this questionnaire in different

  6. Thermometric Titration for Rapid Determination of Trace Water in Jet Fuel

    OpenAIRE

    Hu, Jian-Qiang; Zhang, Jian-Jian; Yang, Shi-Zhao; Xin, Yong-Liang; Guo, Li; Yao, Ting

    2017-01-01

    Water content in jet fuels is detected by thermometric titration (TMT), and the optimal detected system is 2,2-dimethoxypropane as titrant, cyclohexane and isopropanol as titration solvents, and methanesulfonic acid as catalyst in this method. The amounts of oil, concentration and delivery rate of titrant, volumes, and the reliability and accuracy of thermometric titration were emphasized. The results show that the accuracy, validity, and reliability of TMT are excellent by different indicate...

  7. Liquid argon calorimetry for the SSC

    International Nuclear Information System (INIS)

    Gordon, H.A.

    1990-01-01

    Liquid argon calorimetry is a mature technique. However, adapting it to the challenging environment of the SSC requires a large amount of R ampersand D. The advantages of the liquid argon approach are summarized and the issues being addressed by the R ampersand D program are described. 18 refs

  8. Evaluation of aluminosilicate glass sintering during differential scanning calorimetry

    International Nuclear Information System (INIS)

    Souza, Juliana Pereira de

    2015-01-01

    In this work a difference in the baseline in differential scanning calorimetry analyses, observed in a work where aluminosilicate glasses microspheres containing Ho were studied for application in selective internal radiotherapy as hepatocellular carcinoma treatment, was studied. The glasses with nominal composition 53,7 SiO 2 .10,5 Al 2 O 3 . 35,8 MgO in %mol were produced from traditional melting. The first obtained were milled and sieved in the range of 45 a 63 μm. The material was used to produce glass microspheres by the gravitational fall method. The glass powder and the microspheres were characterized by X ray fluorescence spectrometry, laser diffraction, X ray diffraction, differential scanning calorimetry, differential thermal analysis, thermogravimetry, mass spectrometry, and scanning electron microscopy. After the thermal analyses, pellets were formed in the crucibles and were analyzed by scanning electron microscopy, X ray diffraction, and He pycnometry. The difference in the baseline was associated to the viscous flow sintering process and happens because of the decrease in the detected heat flow due to the sample shrinkage. Other events as concurrent crystallization with the sintering process were also studied. (author)

  9. Determination of the protonation enthalpy of humic acid by calorimetric titration technique

    International Nuclear Information System (INIS)

    Kimuro, Shingo; Kirishima, Akira; Sato, Nobuaki

    2015-01-01

    Graphical abstract: The thermodynamic quantities of protonation of humic acid were determined by the combination of potentiometric titration and calorimetric titration. It was observed that the protonation enthalpy and Gibbs free energy had been affected by pH of solution. As a result, the thermodynamics of the protonation reaction of humic acid is influenced by the polyelectrolyte effect and the heterogeneity. - Highlights: • We applied calorimetric titration technique to the protonation of humic acid. • The thermodynamic quantities of protonation of humic acid were determined. • The protonation enthalpy of humic acid is affected by the heterogeneity. • Gibbs free energy of the protonation is affected by the polyelectrolyte effect. - Abstract: In this study, the calorimetric titration technique was used to determine the protonation enthalpy of two reference humic acids and polyacrylic acid. First, we obtained the apparent protonation constant of two kinds of humic acid purchased from IHSS (International Humic Substances Society) and polyacrylic acid by potentiometric titration. Second, we obtained the protonation enthalpy of them by calorimetric titration. The protonation enthalpy of humic acid was affected by pH and the ionic strength of bulk solution. From the comparison of ΔH between humic acid and polyacrylic acid, it was concluded that the pH dependence of ΔH is attributed to the heterogeneity of humic acid. And ΔH of phenolic hydroxyl group in humic acid is strongly influenced by the electric double layer of humic acid’s surface. This is considered to be a reason of the ionic strength dependence of ΔH. On the other hand, Gibbs free energy of the protonation of humic acid is affected by the electrostatic attraction with the progress of dissociation of functional groups such as carboxyl group and phenolic hydroxyl group. Consequently, the thermodynamics of the protonation of humic acid is affected by the polyelectrolyte effect and the

  10. What does calorimetry and thermodynamics of living cells tell us?

    Science.gov (United States)

    Maskow, Thomas; Paufler, Sven

    2015-04-01

    This article presents and compares several thermodynamic methods for the quantitative interpretation of data from calorimetric measurements. Heat generation and absorption are universal features of microbial growth and product formation as well as of cell cultures from animals, plants and insects. The heat production rate reflects metabolic changes in real time and is measurable on-line. The detection limit of commercially available calorimetric instruments can be low enough to measure the heat of 100,000 aerobically growing bacteria or of 100 myocardial cells. Heat can be monitored in reaction vessels ranging from a few nanoliters up to many cubic meters. Most important the heat flux measurement does not interfere with the biological process under investigation. The practical advantages of calorimetry include the waiver of labeling and reactants. It is further possible to assemble the thermal transducer in a protected way that reduces aging and thereby signal drifts. Calorimetry works with optically opaque solutions. All of these advantages make calorimetry an interesting method for many applications in medicine, environmental sciences, ecology, biochemistry and biotechnology, just to mention a few. However, in many cases the heat signal is merely used to monitor biological processes but only rarely to quantitatively interpret the data. Therefore, a significant proportion of the information potential of calorimetry remains unutilized. To fill this information gap and to motivate the reader using the full information potential of calorimetry, various methods for quantitative data interpretations are presented, evaluated and compared with each other. Possible errors of interpretation and limitations of quantitative data analysis are also discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The determination of titratable acidity and total tannins in red wine

    OpenAIRE

    Rajković Miloš B.; Sredović Ivana D.

    2009-01-01

    Titration acidity and content of total tannins in mass-market red wines are analyzed in this paper. The content of total acids in wine, expressed through wine acid, was analyzed by potentiometric titration on 7.00 pH value. According to titratable acidity in analyzed wines, all wines (only) with analyzed parameters according to Regulations about wine quality. The analysis of differential potentiometric curves shows that these curves can give the answer to the question if non organic substance...

  12. Ionic liquids. Combination of combustion calorimetry with high-level quantum chemical calculations for deriving vaporization enthalpies.

    Science.gov (United States)

    Emel'yanenko, Vladimir N; Verevkin, Sergey P; Heintz, Andreas; Schick, Christoph

    2008-07-10

    In this work, the molar enthalpies of formation of the ionic liquids [C2MIM][NO3] and [C4MIM][NO3] were measured by means of combustion calorimetry. The molar enthalpy of fusion of [C2MIM][NO3] was measured using differential scanning calorimetry. Ab initio calculations of the enthalpy of formation in the gaseous phase have been performed for the ionic species using the G3MP2 theory. We have used a combination of traditional combustion calorimetry with modern high-level ab initio calculations in order to obtain the molar enthalpies of vaporization of a series of the ionic liquids under study.

  13. Tritium inventory measurements by 'in-bed' gas flowing calorimetry

    International Nuclear Information System (INIS)

    Hayashi, T.; Suzuki, T.; Yamada, M.; Okuno, K.

    1996-01-01

    In order to establish the 'in-bed' tritium accounting technology for the ITER scale tritium storage system, a gas flowing calorimetry has been studied using a scaled ZrCo bed (25 g tritium capacity). The basic calorimetric characteristics, steady state temperature raise of He gas stream flowing through a secondary coil line fixed in the ZrCo tritide, was measured and correlated with the stored tritium inventory. The results shows that about 4 degrees raise of He stream temperature can be detected for each gram of tritium storage. The sensitivity of this calorimetry is about 0.05 g of tritium, calculated by 0.2 degrees of temperature sensor error. The accuracy is better than 0.25 g of tritium on 25 g storage, evaluated by 2 times of standard deviation from the repeat measurements. This accuracy of < 1% on full storage capacity is satisfied the target accountability to measure ± 1 gram of tritium on 100 g storage for ITER. 13 refs., 7 figs

  14. Hydroxylamine nitrate self-catalytic kinetics study with adiabatic calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Liu Lijun [Mary Kay O' Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States); Wei Chunyang [BASF Corporation, Wyandotte, MI 48192 (United States); Guo Yuyan; Rogers, William J. [Mary Kay O' Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States); Sam Mannan, M. [Mary Kay O' Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States)], E-mail: mannan@tamu.edu

    2009-03-15

    Hydroxylamine nitrate (HAN) is an important member of the hydroxylamine compound family with applications that include equipment decontamination in the nuclear industry and aqueous or solid propellants. Due to its instability and autocatalytic behavior, HAN has been involved in several incidents at the Hanford and Savannah River Site (SRS) [Technical Report on Hydroxylamine Nitrate, US Department of Energy, 1998]. Much research has been conducted on HAN in different areas, such as combustion mechanism, decomposition mechanism, and runaway behavior. However, the autocatalytic decomposition behavior of HAN at runaway stage has not been fully addressed due to its highly exothermic and rapid decomposition behavior. This work is focused on extracting HAN autocatalytic kinetics and analyzing HAN critical behavior from adiabatic calorimetry measurements. A lumped autocatalytic kinetic model for HAN and associated model parameters are determined. Also the storage and handling critical conditions of diluted HAN solution without metal presence are quantified.

  15. Hydroxylamine nitrate self-catalytic kinetics study with adiabatic calorimetry

    International Nuclear Information System (INIS)

    Liu Lijun; Wei Chunyang; Guo Yuyan; Rogers, William J.; Sam Mannan, M.

    2009-01-01

    Hydroxylamine nitrate (HAN) is an important member of the hydroxylamine compound family with applications that include equipment decontamination in the nuclear industry and aqueous or solid propellants. Due to its instability and autocatalytic behavior, HAN has been involved in several incidents at the Hanford and Savannah River Site (SRS) [Technical Report on Hydroxylamine Nitrate, US Department of Energy, 1998]. Much research has been conducted on HAN in different areas, such as combustion mechanism, decomposition mechanism, and runaway behavior. However, the autocatalytic decomposition behavior of HAN at runaway stage has not been fully addressed due to its highly exothermic and rapid decomposition behavior. This work is focused on extracting HAN autocatalytic kinetics and analyzing HAN critical behavior from adiabatic calorimetry measurements. A lumped autocatalytic kinetic model for HAN and associated model parameters are determined. Also the storage and handling critical conditions of diluted HAN solution without metal presence are quantified

  16. Construction and use of an optical semi-automatic titrator employing the technique of reflectance photometry

    International Nuclear Information System (INIS)

    Hwang, Hoon

    2001-01-01

    An optical semi-automatic titrator was constructed employing the technique of the reflectance spectrometry and was tested for the determination of the end points of the acid-base, precipitation, and EDTA titrations. And since the current optical semi-automatic titrator built on the principle of the reflectance spectrometry could be successfully used even for the determination of the end of the end point in the precipitation titration where the solid particles are formed during the titration process, it was found to be feasible that a completely automated optical titrator would be designed and built based on the current findings

  17. Laser-flash calorimetry

    International Nuclear Information System (INIS)

    Takahashi, Y.; Nakamura, J.-I.

    1982-01-01

    The heat capacity of vanadium has been measured by laser-flash calorimetry in the temperature region from 80 to 1000 K. The results are compared with available low- and high-temperature heat capacities, and revised thermodynamic values of vanadium are given. No heat-capacity anomaly has been found in the pure vanadium sample over the temperature range investigated, while a small heat-capacity discontinuity, less than 1.2 J.K -1 .mol -1 , has been observed at 220 to 230 K on the same sample but electropolished before measurement. This anomaly disappeared after annealing at 1000 K in vacuo for 1 h and is attributable to the introduction of a small amount of hydrogen during electropolishing. (author)

  18. Amperometric titration of indium with edta solution in propanol

    International Nuclear Information System (INIS)

    Gevorgyan, A.M.; Talipov, Sh.T.; Khadeev, V.A.; Kostylev, V.S.; Khadeeva, L.A.

    1980-01-01

    Optimum conditions have been chosen for titration of indium with EDTA solution in anhydrous propanol and its mixtures with some aprotic solvents using amperometric and point detection. A procedure is suggested of determining indium microcontents in the presence of large amounts of other elements. The procedure is based on its extraction preseparation followed by direct titration in the extract with a standard EDTA solution [ru

  19. Determination of boron as boric acid by automatic potentiometric titration

    International Nuclear Information System (INIS)

    Midgley, D.

    1988-06-01

    Boron in PWR primary coolant and related waters may be determined as boric acid by titration with sodium hydroxide, using a glass electrode as a pH indicator. With a modern automatic titrator, the analysis is quick, convenient, accurate and precise. In the titration of 8 mg B (e.g. 4 ml of 2000 mg 1 -1 solution), no significant bias was observed and relative standard deviations were about 0.25%. With 0.8 g B, a bias of about 2% appears, although this could be reduced by restandardizing the titrant, but the relative standard deviation was still -1 B, depending on the stage of the fuel cycle. (author)

  20. Comparison of methods for accurate end-point detection of potentiometric titrations

    Science.gov (United States)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  1. Comparison of methods for accurate end-point detection of potentiometric titrations

    International Nuclear Information System (INIS)

    Villela, R L A; Borges, P P; Vyskočil, L

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper

  2. Ruthenium determination in new composite materials by coulometric titration with generated iron(2)

    International Nuclear Information System (INIS)

    Butakova, N.A.; Oganesyan, L.B.

    1983-01-01

    A coulometric technique is developed for ruthenium (4) titration with generated iron (2) in a mixture of hydrochloric-, sulfuric- and phosphoric acids with potentiometric and biammetric indication of the final titration point. Bi (3), Pd (2), Nb (5), Pt (4) Pb (2), Rh (3) do not interfere with the titration. Together with Ru (4) titrated are Ir (4), V (5), Au (3). The method is applied to analyze commercial samples of ruthenium dioxides, lead- and bismuth ruthenites, ruthenium pentafluorides containing 30-80% of ruthenium. The Ssub(r) values do not exceed 0.002

  3. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    Science.gov (United States)

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  4. Titrated flow versus fixed flow Bubble Nasal CPAP for respiratory distress in preterm neonates.

    Directory of Open Access Journals (Sweden)

    Srinivas eMurki

    2015-10-01

    Full Text Available Background: The clinical effects of a pre-fixed flow of air-oxygen versus a flow titrated according to visible bubbling are not well understood.Objective: To compare the effects of a fixed flow (5 L/min and titrated flow ( flow just enough to ensure bubbling at different set pressures on delivered intra-prong pressure, gas exchange and clinical parameters in preterm infants on bubble CPAP for respiratory distress.Methods: Preterm infants less than 35 weeks gestation on bubble CPAP and less than 96 h of age, were enrolled in this cross over study. They were subjected to 30 minute periods of titrated flow and fixed flow. At the end of both epochs, gas flow rate, set pressure, FiO2, SpO2, Silverman retraction score, respiratory rate , abdominal girth, and blood gases were recorded. The delivered intra-prong pressure was measured by an electronic manometer. Results: Sixty nine recordings were made in 54 infants. For each of the set CPAP pressures (4, 5 and 6 cm H2O, the mean delivered pressure with a fixed flow of 5 L/min was higher than that delivered by the titrated flow. During the fixed flow epoch, the delivered pressure was closer to and higher than the set pressure resulting in higher PaO2 and lower PaCO2 as compared to titrated flow epoch. In the titrated flow period, the delivered pressure was consistently lower than the set pressure. Conclusion: In preterm infants on bubble CPAP with set pressures of 4 to 6 cm H2O, a fixed flow of 5 L/min is more effective than a flow titrated to ensure adequate visible bubbling. It achieves higher delivered pressures, better oxygenation and ventilation.

  5. Study of phase transition in hard microcrystalline waxes and wax blends by differential scanning calorimetry

    Czech Academy of Sciences Publication Activity Database

    Kumar, S.; Agrawal, K. M.; Khan, H. U.; Sikora, Antonín

    2004-01-01

    Roč. 22, 3 & 4 (2004), s. 337-345 ISSN 1091-6466 R&D Projects: GA AV ČR KSK4050111 Institutional research plan: CEZ:AV0Z4050913 Keywords : phase transition * hard microscrystalline waxes * differential scanning calorimetry Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.312, year: 2004

  6. A rapid method for titration of ascovirus infectivity.

    Science.gov (United States)

    Han, Ningning; Chen, Zishu; Wan, Hu; Huang, Guohua; Li, Jianhong; Jin, Byung Rae

    2018-05-01

    Ascoviruses are a recently described family and the traditional plaque assay and end-point PCR assay have been used for their titration. However, these two methods are time-consuming and inaccurate to titrate ascoviruses. In the present study, a quick method for the determination of the titer of ascovirus stocks was developed based on ascovirus-induced apoptosis in infected insect cells. Briefly, cells infected with serial dilutions of virus (10 -2 -10 -10 ) for 24 h were stained with trypan blue. The stained cells were counted, and the percentage of nonviable cells was calculated. The stained cell rate was compared between virus-infected and control cells. The minimum-dilution group that had a significant difference compared with control and the maximum-dilution group that had no significant difference were selected and then compared each well of the two groups with the average stained cell rate of control. The well was marked as positive well if the stained cell rate was higher than the average stained cell rate of control wells; otherwise, the well was marked as negative wells. The percentage of positive wells were calculated according to the number of positive. Subsequently, the virus titer was calculated through the method of Reed and Muench. This novel method is rapid, simple, reproducible, accurate, and less material-consuming and eliminates the subjectivity of the other procedures for titrating ascoviruses. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Scintillating Fibre Calorimetry at the LHC

    CERN Multimedia

    2002-01-01

    Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. The lead/scintillating fibre calorimeter technique provides a fast signal response well matched to the LHC rate requirements. It can be made to give equal response for electrons and hadrons (compensation) with good electromagnetic and hadronic energy resolutions.\\\\ \\\\ The aim of this R&D proposal is to study in detail the aspects that are relevant for application of this type of calorimeter in an LHC environment, including its integration in a larger system of detectors, e.g.~projective geometry, radiation hardness, light detection, calibration and stability monitoring, electron/hadron separation.....

  8. The ion-sensitive field effect transistor in rapid acid-base titrations

    NARCIS (Netherlands)

    Bos, M.; Bergveld, Piet; van Veen-Blaauw, A.M.W.

    1979-01-01

    Ion-sensitive field effect transistors (ISFETs) are used as the pH sensor in rapid acid—base titrations. Titration speeds at least five times greater than those with glass electrodes are possible for accuracies better than ±1%.

  9. Extensive studies on CeF3 crystals, a good candidate for electromagnetic calorimetry at future accelerators

    International Nuclear Information System (INIS)

    Auffray, E.; Baccaro, S.; Beckers, T.; Benhammou, Y.; Belsky, A.N.; Borgia, B.; Boutet, D.; Chipaux, R.; Dafinei, I.; De Notaristefani, F.; Depasse, P.; Dujardin, C.; El Mamouni, H.; Faure, J.L.; Fay, J.; Goyot, M.; Gupta, S.K.; Gurtu, A.; Hillemanns, H.; Ille, B.; Kirn, T.; Lebeau, M.; Lebrun, P.; Lecoq, P.; Mares, J.A.; Martin, J.P.; Mikhailin, V.V.; Moine, B.; Nelissen, J.; Nikl, M.; Pedrini, C.; Raghavan, R.; Sahuc, P.; Schmitz, D.; Schneegans, M.; Schwenke, J.; Tavernier, S.; Topa, V.; Vasil'ev, A.N.; Vivargent, M.; Walder, J.P.

    1996-01-01

    In the framework of its search for new heavy, fast and radiation hard scintillators for calorimetry at future colliders, the Crystal Clear Collaboration performed a systematic investigation of the properties and of the scintillation and radiation damage mechanisms of CeF 3 monocrystals. Many samples of various dimensions up to 3 x 3 x 28 cm 3 were produced by industry and characterised in the laboratories by different methods such as: optical transmission, light yield and decay time measurements, excitation and emission spectra, gamma and neutron irradiations. The results of these measurements are discussed. The measured light yield is compared to the theoretical expectations. Tests in high energy electron beams on a crystal matrix were also performed. The suitability of CeF 3 for calorimetry at high rate machines is confirmed. Production and economical considerations are discussed. (orig.)

  10. Coulometrische titration von hypochloriten und chloraten.

    Science.gov (United States)

    Gründler, P; Holzapfel, H

    1970-03-01

    Hypochlorite was determined by direct coulometric titration with iron(II) in an acetate buffered solution. Chlorate was titrated with titanium(III) in 2M hydrochloric acid. Amperometric indication with one and two electrodes, respectively, was used. Mixtures of hypochlorites and chlorates, e.g., in industrial electrolytes, may be analysed. On a déterminé l'hypochlorite par titrage coulométrique direct avec le fer(II) dans une solution tamponnée à l'acétate. On a titré le chlorate avec le titane(III) en acide chlorhydrique 2M. On a utilisé l'indication ampérométrique une et deux électrodes respectivement. On peut analyser des mélanges d'hypochlorites et de chlorates, par exemple dans des électrolytes industriels.

  11. The Effect of Metal Concentration on the Parameters Derived from Complexometric Titrations of Trace Elements in Seawater—A Model Study

    Directory of Open Access Journals (Sweden)

    Martha Gledhill

    2017-08-01

    Full Text Available In this study we examine the impact of dissolved metal concentrations on the parameters that are commonly determined from complexometric titrations in seawater. We use the non-ideal competitive adsorption (NICA model within the framework of the chemical speciation program visual MINTEQ with iron as a model metal. We demonstrate that dissolved iron concentrations effect the determined parameters for a heterogeneous binding site distribution with a fixed concentration of dissolved organic carbon. The commonly used terms “ligand concentration” and “binding constant” are therefore dependent on metal concentration, so we adopt the terminology suggested by Town and Filella (2000 and use the terms ligand quotient and stability quotient here. The systematic increase in the ligand quotient with dissolved iron concentration likely contributes toward the trend of increasing ligand quotient with dissolved iron concentration observed in field studies, and makes it hard to assign an objective meaning to the parameter. We suggest that calculation of the side reaction coefficient, a parameter that describes the probability that any added metal will be complexed, could be less prone to bias and misinterpretation than calculation of conditional stability and ligand quotients. We explore the impact of experimental design on side reaction coefficients by applying different detection windows, and multiwindow and reverse titration approaches. We identify the method that results in the best estimates of side reaction coefficients over a range of iron concentrations between 0.1 and 1.5 nmol L−1. We find that single window titrations can only reliably estimate side reaction coefficients over a limited range of iron concentrations. Multiwindow titrations provided estimates of side reaction coefficients within the 99% confidence interval of the values calculated directly from the NICA model at all iron concentrations examined here. We recommend that future

  12. The coulometric titration of acids and bases in dimethylsulfoxide media

    NARCIS (Netherlands)

    Bos, M.; IJpma, S.T.; Dahmen, E.A.M.F.

    1976-01-01

    The coulometric titration of 20–200 μeq of acids and bases in DMSO media is described. In the titration of bases, the electro-oxidation of hydrogen at a platinized platinum electrode is used as the source of protons. The conditions for 100 % current efficiency at this electrode are low current

  13. Titration of thorium and rare earths with ethylenediaminetetraacetic acid using semimethylthymol blue by visual end-point indication

    International Nuclear Information System (INIS)

    Hafez, M.A.H.; Kenawy, I.M.M.; Ramadan, M.A.M.

    1994-01-01

    The precision and accuracy attainable in direct complexometric titrations of Thsup(4+) consecutively with either lighter (La 3+ , Nd 3+ , Sm 3+ , Eu 3+ or Gd 3+ ) or heavier lanthanides (Dy 3+ ) in different proportions using Semimethylthymol Blue (SMTB) as a metallochromic indicator and disodium dihydrogen ethylenediaminetetraacetate were studied. Thorium (IV) was titrated at pH 2, the Ph was adjusted to 5.5-6.0 by adding hexamethylenetetramine (hexamine) buffer and acetylacetone-acetone solution and La 3+ (or Nd 3+ , Sm 3+ , Eu 3+ , Gd 3+ or Dy 3+ ) was then titrated. A comparison of the indicators SMTB and Methylthymol Blue (MTB) for successive titrations of Th 4+ and any of the rare earth ions was carried out. The proposed titration method was applied successfully to some naturally occurring ores and minerals containing thorium and some lanthanides and the results were satisfactory. (Author)

  14. Comparison of the clinical outcomes between unattended home APAP and polysomnography manual titration in obstructive sleep apnea patients.

    Science.gov (United States)

    Wongsritrang, Krongthong; Fueangkamloon, Sumet

    2013-09-01

    To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.

  15. Influence of Multi-Valency, Electrostatics and Molecular Recognition on the Adsorption of Transition Metal Complexes on Metal Oxides: A Molecular Approach to Catalyst Synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Rioux, Robert M. [Pennsylvania State Univ., University Park, PA (United States)

    2017-03-31

    In this work, we have primarily utilized isothermal titration calorimetry (ITC) and complimentary catalyst characterization techniques to study and assess the impact of solution conditions (i.e., solid-liquid) interface on the synthesis of heterogeneous and electro-catalysts. Isothermal titration calorimetry is well-known technique from biochemistry/physics, but has been applied to a far lesser extent to characterize buried solid-liquid interfaces in materials science. We demonstrate the utility and unique information provided by ITC for two distinct catalytic systems. We explored the thermodynamics associated catalyst synthesis for two systems: (i) ion-exchange or strong electrostatic adsorption for Pt and Pd salts on silica and alumina materials (ii) adsorption to provide covalent attachment of metal and metal-oxo clusters to Dion-Jacobsen perovskite materials.

  16. Ultra-Fast Hadronic Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Denisov, Dmitri [Fermilab; Lukić, Strahinja [VINCA Inst. Nucl. Sci., Belgrade; Mokhov, Nikolai [Fermilab; Striganov, Sergei [Fermilab; Ujić, Predrag [VINCA Inst. Nucl. Sci., Belgrade

    2017-12-18

    Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations w.r.t. the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 3 ns providing opportunity for ultra-fast calorimetry. Simulation results for an "ideal" calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.

  17. Simultaneous determination of equivalence volumes and acid dissociation constants from potentiometric titration data.

    Science.gov (United States)

    Papanastasiou, G; Ziogas, I

    1995-06-01

    New iterative methods for analysis of potentiometric titration data of (a) mixtures of weak monoprotic acids with their conjugate bases, (b) solutions of polyprotic (di- and triprotic) acids, and (c) mixtures of two diprotic acids are presented. These methods, using data exclusively resulting from the acidic region of the titration curve permits the accurate determination of the analytical concentration of one or more acids even if the titration is stopped well before the end point of the titration. For the titration of a solution containing a conjugate acid/base pair, the proposed procedure enables the extraction of the initial composition of the mixture, as well as the dissociation constant of the concerned acid. Thus, it is possible by this type of analysis to distinguish whether a weak acid has been contaminated by a strong base and define the extent of the contamination. On the other hand, for the titration of polyprotic acids, the proposed approach enables the extraction of the accurate values of the equivalence volume and the dissociation constants K(i) even when the ionization stages overlap. Finally, for the titration of a mixture of two diprotic acids the proposed procedure enables the determination of the composition of the mixture even if the sum of the concentrations of the acids is not known. This method can be used in the analysis of solutions containing two diastereoisomeric forms of a weak diprotic acid. The test of the proposed procedures by means of ideal and Monte Carlo simulated data revealed that these methods are fairly applicable even when the titration data are considerably obscured by 'noise' or contain an important systematic error. The proposed procedures were also successfully applied to experimental titration data.

  18. Complex coacervates of hyaluronic acid and lysozyme

    DEFF Research Database (Denmark)

    Water, Jorrit J.; Schack, Malthe M.; Velazquez-Campoy, Adrian

    2014-01-01

    stoichiometry was determined using solution depletion and isothermal titration calorimetry. The binding stoichiometry of lysozyme to hyaluronic acid (870 kDa) determined by solution depletion was found to be 225.9 ± 6.6 mol, or 0.1 bound lysozyme molecules per hyaluronic acid monomer. This corresponded well...... with that obtained by isothermal titration calorimetry of 0.09 bound lysozyme molecules per hyaluronic acid monomer. The complexation did not alter the secondary structure of lysozyme measured by Fourier-transform infrared spectroscopy overlap analysis and had no significant impact on the Tm of lysozyme determined...

  19. Thermodynamics of the interaction of γ-cyclodextrin and tauro- and glyco-conjugated bile salts

    DEFF Research Database (Denmark)

    Schönbeck, Jens Christian Sidney; Westh, Peter; Holm, René

    2013-01-01

    The structural differences in the interaction between natural γ-cyclodextrin and bile salts common in rat, dog and man was were investigated by 1H-ROESY and 13C NMR and molecular modeling and the thermodynamic parameters of the reaction by isothermal titration calorimetry. The γ-cyclodextrin was ......The structural differences in the interaction between natural γ-cyclodextrin and bile salts common in rat, dog and man was were investigated by 1H-ROESY and 13C NMR and molecular modeling and the thermodynamic parameters of the reaction by isothermal titration calorimetry. The γ...

  20. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    Directory of Open Access Journals (Sweden)

    Grace Wu

    Full Text Available Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration.To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia.Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration.Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3, respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute.Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  1. Scintillating glasses for total absorption dual readout calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bonvicini, V. [INFN, Trieste; Driutti, A. [Udine U.; Cauz, D. [Udine U.; Pauletta, G. [Udine U.; Rubinov, P. [Fermilab; Santi, L. [Udine U.; Wenzel, H. [Fermilab

    2012-01-01

    Scintillating glasses are a potentially cheaper alternative to crystal - based calorimetry with common problems related to light collection, detection and processing. As such, their use and development are part of more extensive R&D aimed at investigating the potential of total absorption, combined with the readout (DR) technique, for hadron calorimetry. A recent series of measurements, using cosmic and particle beams from the Fermilab test beam facility and scintillating glass with the characteristics required for application of the DR technique, serve to illustrate the problems addressed and the progress achieved by this R&D. Alternative solutions for light collection (conventional and silicon photomultipliers) and signal processing are compared, the separate contributions of scintillation and Cherenkov processes to the signal are evaluated and results are compared to simulation.

  2. flower extract as an improvised indicator in acid – base titration

    African Journals Online (AJOL)

    USER

    laboratory practical with an instructional material that is useful, economical, simple and accurate for the said titration. Therefore, it is recommended for integrated science and chemistry instructions. Keywords: Flower, acid, base, indicator, titration. INTRODUCTION. In Nigeria, factors militating against science education.

  3. Nucleation behavior of melted Bi films at cooling rates from 101 to 104 K/s studied by combining scanning AC and DC nano-calorimetry techniques

    International Nuclear Information System (INIS)

    Xiao, Kechao; Vlassak, Joost J.

    2015-01-01

    Highlights: • We proposed a general data reduction scheme that combines scanning AC and DC calorimetry results for the study of reaction kinetics. • Calorimetry measurements at cooling rates ranging from 30 K/s to 20,000 K/s were achieved. • Upon initial melting, the Bi thin-film sample breaks up into thousands of isolated islands, and highly repeatable nucleation behavior is observed. • The nucleation rate of melted Bi is calculated, which can be well described by classical nucleation theory over a wide range of cooling rates. - Abstract: We study the nucleation behavior of undercooled liquid Bi at cooling rates ranging from 10 1 to 10 4 K/s using a combination of scanning DC and AC nano-calorimetry techniques. Upon initial melting, the Bi thin-film sample breaks up into silicon nitride-coated isolated islands. The number of islands in a typical sample is sufficiently large that highly repeatable nucleation behavior is observed, despite the stochastic nature of the nucleation process. We establish a data reduction technique to evaluate the nucleation rate from DC and AC calorimetry results. The results show that the driving force for the nucleation of melted Bi is well described by classical nucleation theory over a wide range of cooling rates. The proposed technique provides a unique and efficient way to examine nucleation kinetics with cooling rates over several orders of magnitude. The technique is quite general and can be used to evaluate reaction kinetics in other materials

  4. Null-point titration measurements of free magnesium in stored erythrocytes

    International Nuclear Information System (INIS)

    Bock, J.L.; Yusuf, Y.; Puntillo, E.

    1987-01-01

    Free intracellular magnesium concentration (Mg/sub i/) was measured in stored human erythrocytes, using null-point titration with ionophore A23187. For cells stored 31 P NMR spectroscopy, which showed a decrease in Mg/sub i/ with storage. However, the NMR measurements are performed with no pretreatment of the cells, while the null-point method requires an initial washing step, which alters pH/sub i/ and may also alter Mg/sub i/. The titration-measured Mg/sub i/ values are still surprisingly low for long-stored cells, considering that depletion of ATP and 2,3-DPG should release bound Mg. Using the titration-measured Mg/sub i/ values along with measurements of total Mg, ATP, and 2,3-DPG, they estimate that an additional buffer contains about 47% of total Mg in cells stored 21 days. Mg/sub i/ determinations by both 31 P NMR and null-point titration thus indicate that erythrocyte Mg is largely bound to a high-capacity, low-affinity buffer whose relative importance increases during cell storage. Discrepancies between the methods require further investigation

  5. Correct titration of non-drugs and some other methodological issues.

    Science.gov (United States)

    Beneke, M; Rasmus, W; Rød, I S; Fritze, J

    1994-01-01

    Doctors' prescription and dosing behaviour was investigated using data from 9 clinical trials in 550 patients treated with psychotropics. 7 trials were conducted under double- and 2 under single-blind conditions. In 3 of these trials, oral and i.m. preparations were used demanding a double-dummy design. All patients were evaluated on a weekly or 2-week basis using psychopathological rating scales (i.e. Hamilton Anxiety Scale, Hamilton Depression Scale, Clinical Global Impressions, Simpson and Angus EPS). It was found that (a) oral-medication titration was 3- to 4-fold more broad-ranging than i.m. medication titration, (b) oral placebo was titrated to the same extent as the oral investigational drugs, and (c) the titration schedule did not follow protocol requirements. Moreover, the average doses in all drug and placebo groups were the same. Concomitant medication like sleep inducers was found to be more closely related to doctors' habits than to actual medical need. Independent of trial and investigational drug, 10-33% of all patients received additional sleep inducers.

  6. Acidity titration curves - a versatile tool for the characterisation of acidic mine waste water

    International Nuclear Information System (INIS)

    Fyson, A.

    2000-01-01

    Acidity titrations with NaOH are valuable tools for characterisation of acidic mine waters. - Titrations can be used to estimate metal concentrations. - Titrations can be carried out in the field, minimising changes in water chemistry due to sample handling time and procedure. (orig.)

  7. Protometric thermometric titrations of sparingly soluble compounds in water in the presence of n-octanol.

    Science.gov (United States)

    Burgot, G; Burgot, J-L

    2002-10-15

    Thermometric titrimetry permits titration of acido-basic compounds in water in the presence of n-octanol. n-Octanol permits the solubilization of protolytes and moreover may also displace the equilibria of the titration reactions. Hydrochlorides of highly insoluble derivatives such as phenothiazine derivatives can be titrated with satisfactory accuracy and precision by sodium hydroxide despite their high pK(a) values. Likewise barbiturate salts can be titrated by hydrochloric acid. In the case of some salts, the methodology may permit the sequential titration of the ion and counter ion. Copyright 2002 Elsevier Science B.V.

  8. A study of the use of lead fluoride for electromagnetic calorimetry

    International Nuclear Information System (INIS)

    Woody, C.L.; Kierstead, J.A.; Levy, P.W.; Stoll, S.; Weingarten, A.B.; Anderson, D.F.; Ramberg, E.J.; Kuno, Y.; Macdonald, J.A.; Konaka, A.; Hutcheon, D.A.

    1992-01-01

    A study has been made on the properties of lead fluoride as a Cherenkov material for use in electromagnetic calorimetry. A prototype calorimeter module consisting of a 5 x 5 array of 2.1 x 2.1 x 18.5 cm 3 crystals has been built and tested in a test beam at the Brookhaven AGS. Results are given on energy resolution, shower size and e/π separation for electrons and pions in the range from 1--4 GeV. The light output has been measured to give approx-gt 1000 photoelectrons per MeV in good quality crystals, and to provide useful signals down to as low as 32 MeV. Measurements were also made on radiation damage in lead fluoride using 60 Co gamma rays and high energy ionizing particles, as well as on thermoluminescence after irradiation. It was found that only modest damage occurs up to a level of ∼ 30 Krad in large, calorimeter size crystals, and that the damage can be easily removed by optical bleaching

  9. Protocol adherence for continuously titrated interventions in randomized trials: an overview of the current methodology and case study.

    Science.gov (United States)

    Lauzier, F; Adhikari, N K; Seely, A; Koo, K K Y; Belley-Côté, E P; Burns, K E A; Cook, D J; D'Aragon, F; Rochwerg, B; Kho, M E; Oczkowksi, S J W; Duan, E H; Meade, M O; Day, A G; Lamontagne, F

    2017-07-17

    The standard definition for protocol adherence is the proportion of all scheduled doses that are delivered. In clinical research, this definition has several limitations when evaluating protocol adherence in trials that study interventions requiring continuous titration. Building upon a specific case study, we analyzed a recent trial of a continuously titrated intervention to assess the impact of different definitions of protocol deviations on the interpretation of protocol adherence. The OVATION pilot trial was an open-label randomized controlled trial of higher (75-80 mmHg) versus lower (60-65 mmHg) mean arterial pressure (MAP) targets for vasopressor therapy in shock. In this trial, potential protocol deviations were defined as MAP values outside the targeted range for >4 consecutive hours during vasopressor therapy without synchronous and consistent adjustments of vasopressor doses. An adjudication committee reviewed each potential deviation to determine if it was clinically-justified or not. There are four reasons for this contextual measurement and reporting of protocol adherence. First, between-arm separation is a robust measure of adherence to complex protocols. Second, adherence assessed by protocol deviations varies in function of the definition of deviations and the frequency of measurements. Third, distinguishing clinically-justified vs. not clinically-justified protocol deviations acknowledges clinically sensible bedside decision-making and offers a clear terminology before the trial begins. Finally, multiple metrics exist to report protocol deviations, which provides different information but complementary information on protocol adherence. In trials of interventions requiring continuous titration, metrics used for defining protocol deviations have a considerable impact on the interpretation of protocol adherence. Definitions for protocol deviations should be prespecified and correlated with between-arm separation, if it can be measured.

  10. Calorimetric Evidence about the Application of the Concept of CMC to Asphaltene Self-Association

    DEFF Research Database (Denmark)

    Garcia, Daniel Merino; Andersen, Simon Ivar

    2005-01-01

    that asphaltenes may also have a concentration at which self-association occurs (CMC). This article presents evidence found by calorimetry and spectroscopic techniques, that suggest that this concept may not be adequate for asphaltene self-association in toluene solutions. Isothermal titration calorimetry has been...

  11. [Research on determination of chemical purity of andrographolide by coulometric titration method].

    Science.gov (United States)

    Yang, Ning; Yang, Dezhi; Xu, Lishen; Lv, Yang

    2010-04-01

    The determination of chemical purity of andrographolide by coulometric titration method is studied in this paper. The coulometric titration was carried out in a mixture composed of 4 mol x L(-1) hydrochloric acid and 1 mol x L(-1) potassium bromide solution and 1 mol x L(-1) potassium nitrate solution (1:1). Bromine is electrogenerated at the anode and reacts with the andrographolide. The number of electrons involved in the eleatrode reaction is 2. Purity of andrographolide is 99.76% compared with 99.77% utilizing area normalization method by HPLC. The RSD are 0.33% and 0.02% respectively. The results from two methods are consistent, so the determination of chemical purity of andrographolide by coulometric titration method is scientific and feasible. The method is rapid, simple, convenient, sensitive and accurate. The reference material is not essential in the method. The method is suitable for determination of chemical purity of andrographolide.

  12. pH-metric solubility. 3. Dissolution titration template method for solubility determination.

    Science.gov (United States)

    Avdeef, A; Berger, C M

    2001-12-01

    The main objective of this study was to develop an effective potentiometric saturation titration protocol for determining the aqueous intrinsic solubility and the solubility-pH profile of ionizable molecules, with the specific aim of overcoming incomplete dissolution conditions, while attempting to shorten the data collection time. A modern theory of dissolution kinetics (an extension of the Noyes-Whitney approach) was applied to acid-base titration experiments. A thermodynamic method was developed, based on a three-component model, to calculate interfacial, diffusion-layer, and bulk-water reactant concentrations in saturated solutions of ionizable compounds perturbed by additions of acid/base titrant, leading to partial dissolution of the solid material. Ten commercial drugs (cimetidine, diltiazem hydrochloride, enalapril maleate, metoprolol tartrate, nadolol, propoxyphene hydrochloride, quinine hydrochloride, terfenadine, trovafloxacin mesylate, and benzoic acid) were chosen to illustrate the new titration methodology. It was shown that the new method is about 10 times faster in determining equilibrium solubility constants, compared to the traditional saturation shake-flask methods.

  13. Spasmodic dysphonia: a seven-year audit of dose titration and demographics in the Indian population.

    Science.gov (United States)

    Nerurkar, N K; Banu, T P

    2014-07-01

    This study aimed to evaluate the demographics of spasmodic dysphonia in the Indian population and to analyse the optimum dose titration of botulinum toxin type A in this group. A comparative analysis with international studies was also performed. The study involved a retrospective analysis and audit of botulinum toxin type A dose titration in spasmodic dysphonia patients who visited our voice clinic between January 2005 and January 2012. The average total therapeutic dose required for patients with adductor spasmodic dysphonia was 4.2 U per patient per vocal fold (total 8.4 U per patient), and for patients with abductor spasmodic dysphonia, it was 4.6 U per patient. Our audit revealed that 80 per cent of the spasmodic dysphonia patients were male, which contrasts dramatically with international studies, wherein around 80 per cent of spasmodic dysphonia patients were female. Our study also revealed a higher dose titration of botulinum toxin for the Indian spasmodic dysphonia population in both adductor and abductor spasmodic dysphonia cases.

  14. Determination of acid–base properties of HCl acid activated palygorskite by Potentiometrie titration

    OpenAIRE

    N. FriniSrasra; E.Srasra

    2008-01-01

    The surface acidity of raw and acid activated palygorskite clay were studied by acid-base potentiometric titration. The Gran plot method was applied for the hydroxide titration and the total surface site (Hs) and the average number of protons reacted per surface site (Z) of palygorskite samples at a given ionic strength were calculated. Acid treatment increases the clay acidity and modifies its surface charge. The point of zero charge value, determined by the common crossing point of Z vs pH ...

  15. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey.

    Science.gov (United States)

    Berard, Lori; Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2018-02-01

    Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such "clinical inertia" results in poor glycaemic control and high risk of long-term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. An online survey (July-August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%-42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self-titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. A disconnect exists between HCP- and patient-perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP-patient communication, and provide support and educational tools. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  16. The binding of aluminum to mugineic acid and related compounds as studied by potentiometric titration.

    Science.gov (United States)

    Yoshimura, Etsuro; Kohdr, Hicham; Mori, Satoshi; Hider, Robert C

    2011-08-01

    The phytosiderophores, mugineic acid (MA) and epi-hydroxymugineic acid (HMA), together with a related compound, nicotianamine (NA), were investigated for their ability to bind Al(III). Potentiometric titration analysis demonstrated that MA and HMA bind Al(III), in contrast to NA which does not under normal physiological conditions. With MA and HMA, in addition to the Al complex (AlL), the protonated (AlLH) and deprotonated (AlLH(-1)) complexes were identified from an analysis of titration curves, where L denotes the phytosiderophore form in which all the carboxylate functions are ionized. The equilibrium formation constants of the Al(III) phytosiderophore complexes are much smaller than those of the corresponding Fe(III) complexes. The higher selectivity of phytosiderophores for Fe(III) over Al(III) facilitates Fe(III) acquisition in alkaline conditions where free Al(III) levels are higher than free Fe(III) levels.

  17. Physicochemical characterization of pitches by differential scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lahaye, J.; Ehrburger, P.; Saint-Romain, J.L.; Couderc, P.

    1987-11-01

    The glass transition characterization of pitches has been studied by differential scanning calorimetry (d.s.c.). Experimental results and theoretical considerations indicate that: (1) the average molecular mass of pitches can be characterized by the apparent activation energy of the relaxation phenomenon of pitch molecules; (2) the molecular polydispersity is correlated with the width of the glass transition. Characterization of pitch by d.s.c. is well adapted to follow pitch transformation during heat treatment. 6 refs., 6 figs., 4 tabs.

  18. The Effect of Metal Concentration on the Parameters Derived from Complexometric Titrations of Trace Elements in Seawater—A Model Study

    NARCIS (Netherlands)

    Gledhill, M.; Gerringa, L.J.A.

    2017-01-01

    In this study we examine the impact of dissolved metal concentrations on the parametersthat are commonly determined from complexometric titrations in seawater. We use thenon-ideal competitive adsorption (NICA) model within the framework of the chemicalspeciation program visual MINTEQ with iron as a

  19. A fully automatic system for acid-base coulometric titrations

    OpenAIRE

    Cladera, A.; Caro, A.; Estela, J. M.; Cerdà, V.

    1990-01-01

    An automatic system for acid-base titrations by electrogeneration of H+ and OH- ions, with potentiometric end-point detection, was developed. The system includes a PC-compatible computer for instrumental control, data acquisition and processing, which allows up to 13 samples to be analysed sequentially with no human intervention. The system performance was tested on the titration of standard solutions, which it carried out with low errors and RSD. It was subsequently applied to the analysis o...

  20. Application of »Mass Titration« to Determination of Surface Charge of Metal Oxides

    OpenAIRE

    1998-01-01

    The mass titration method, used for the point of zero charge determination, was extended to the measurement of the surface charge density. The results agree with the common method, which is the acid-base titration of the colloidal suspension. The advantage of mass titration is that one does not need to perform blank titration, instead one simply adds metal oxide powder to the electrolyte aqueous solution of known pH. To cover the pH range above and below the point of zero charge, two experime...

  1. Study of phase changing characteristics of granular composites using differential scanning calorimetry

    International Nuclear Information System (INIS)

    Rady, Mohamed

    2009-01-01

    Characterization of the phase changing behavior of granular materials is an important issue for design and optimization of latent heat thermal energy storage (LHTES) systems. In the present work, differential scanning calorimetry (DSC) has been used to study the phase changing behavior of granular composites consisting of ceramic encapsulated phase change material (EPCM) with particle diameters of 1-3 mm. The obtained DSC curves characterizing melting and solidification of the composite material are shown to be dependent upon the values of heating and cooling rates. Direct utilization of the measured DSC curves could result in an inexact representation of the sample enthalpy change. A simple procedure has been advised to obtain accurate quantitative results from the DSC measurements based on the estimation of the thermal resistance between the sample and its enclosure. Analysis of the evolution of latent heat of EPCM with temperature at different values of cooling/heating rates is presented.

  2. The Critical Micelle Concentration of Asphaltenes as Measured by Calorimetry

    DEFF Research Database (Denmark)

    Andersen, Simon Ivar; Christensen, S. D.

    2000-01-01

    Micellization of asphaltenes in solution has been investigated using a micro calorimetric titration procedure (Andersen, S. I.; Birdi, K. S. J Colloid Interface Sci. 1991, 142, 497). The method uses the analysis of heat of dissociation and dilution of asphaltene micelles when a pure solvent (or...... solvent mixture) is titrated with a solution of asphaltene in the same solvent. The asphaltene concentration of the injected solution is at a level above the critical micelle concentration (CMC). In the present paper the procedure is applied in investigation of asphaltenes as well as subfractions...

  3. A study on the alkalimetric titration with gran plot in noncomplexing media for the determination of free acid in spent fuel solutions

    International Nuclear Information System (INIS)

    Suh, Moo Yul; Lee, Chang Heon; Sohn, Se Chul; Kim, Jung Suk; Kim, Won Ho; Eom, Tae Yoon

    1999-01-01

    Based on the study of hydrolysis behaviour of U(VI) ion and major fission product metal ions such as Cs(I), Ce(III), Nd(III), Mo(VI), Ru(II), and Zr(VI) in the titration media, the performance of noncomplexing-alkalimetric titration method for the determination of free acid in the presence of these metal ions was investigated and its results were compared to those from the complexing methods. The free acidities could be determined as low as 0.05 meq in uranium solutions in which the molar ratio of U(VI)/H + was less than 5, when the end-point of titration was estimated by Gran plot. The biases in the determinations were less than ±1% and about +3% respectively for 0.4 meq and 0.05 meq of free acid at the U(VI)/H + molar ratio of up to 5. Applicability of this method to the determination of free acid in spent fuel solutions was confirmed by the analysis of nitric acid content in simulated spent fuel solutions and in a real spent fuel solution

  4. Subject-driven titration of biphasic insulin aspart 30 twice daily is non-inferior to investigator-driven titration in Chinese patients with type 2 diabetes inadequately controlled with premixed human insulin: A randomized, open-label, parallel-group, multicenter trial.

    Science.gov (United States)

    Yang, Wenying; Zhu, Lvyun; Meng, Bangzhu; Liu, Yu; Wang, Wenhui; Ye, Shandong; Sun, Li; Miao, Heng; Guo, Lian; Wang, Zhanjian; Lv, Xiaofeng; Li, Quanmin; Ji, Qiuhe; Zhao, Weigang; Yang, Gangyi

    2016-01-01

    The present study was to compare the efficacy and safety of subject-driven and investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) twice daily (BID). In this 20-week, randomized, open-label, two-group parallel, multicenter trial, Chinese patients with type 2 diabetes inadequately controlled by premixed/self-mixed human insulin were randomized 1:1 to subject-driven or investigator-driven titration of BIAsp 30 BID, in combination with metformin and/or α-glucosidase inhibitors. Dose adjustment was decided by patients in the subject-driven group after training, and by investigators in the investigator-driven group. Eligible adults (n = 344) were randomized in the study. The estimated glycated hemoglobin (HbA1c) reduction was 14.5 mmol/mol (1.33%) in the subject-driven group and 14.3 mmol/mol (1.31%) in the investigator-driven group. Non-inferiority of subject-titration vs investigator-titration in reducing HbA1c was confirmed, with estimated treatment difference -0.26 mmol/mol (95% confidence interval -2.05, 1.53) (-0.02%, 95% confidence interval -0.19, 0.14). Fasting plasma glucose, postprandial glucose increment and self-measured plasma glucose were improved in both groups without statistically significant differences. One severe hypoglycemic event was experienced by one subject in each group. A similar rate of nocturnal hypoglycemia (events/patient-year) was reported in the subject-driven (1.10) and investigator-driven (1.32) groups. There were 64.5 and 58.1% patients achieving HbA1c titration of BIAsp 30 BID was as efficacious and well-tolerated as investigator-titration. The present study supported patients to self-titrate BIAsp 30 BID under physicians' supervision.

  5. Clozapine Titration for People in Early Psychosis: A Chart Review and Treatment Guideline.

    Science.gov (United States)

    Ballon, Jacob S; Ashfaq, Hera; Noordsy, Douglas L

    2018-06-01

    The use of clozapine, particularly in young people, is often limited by early treatment-emergent adverse effects including drowsiness and lethargy. Concerns about adverse effects, medication adherence, and the need for blood monitoring often impede the use of clozapine in this population, leading to repeated trials of less effective medications. Current clozapine dosing recommendations are based on people further in the course of their illness and thus reflect different responsiveness and sensitivities to antipsychotic medication. As such, there is a need for evidence-based guidelines for titration and dosing of clozapine among people in early psychosis. We performed a chart review of 14 people treated with clozapine within our early psychosis team. Data regarding dose titration, response, time to discontinuation, symptom severity, weight gain, and other adverse effects were gathered at clozapine initiation, 3 months, and last available visit on clozapine. People treated with slow titration within their first year of psychosis onset achieved sustained response at very low maintenance doses (mean dose = 81 mg/d, mean duration of treatment = 200 weeks) compared with slow titration with longer duration of illness (mean dose = 350 mg/d, mean duration of treatment = 68 weeks) or standard dose titration in early psychosis (mean dose = 112 mg/d, mean duration of treatment = 38 weeks). The most common adverse effects in all groups were weight gain and sedation, with the groups requiring higher mean doses reporting a broader range of adverse effects. There was no apparent difference in the clinical global impression for severity or improvement between the slow titration and standard titration groups in people with early psychosis. These observations are synthesized into a proposed treatment guideline for use of clozapine among people in early psychosis. We describe development of a slow titration approach to initiating clozapine among people in early psychosis. This

  6. End-point detection in potentiometric titration by continuous wavelet transform.

    Science.gov (United States)

    Jakubowska, Małgorzata; Baś, Bogusław; Kubiak, Władysław W

    2009-10-15

    The aim of this work was construction of the new wavelet function and verification that a continuous wavelet transform with a specially defined dedicated mother wavelet is a useful tool for precise detection of end-point in a potentiometric titration. The proposed algorithm does not require any initial information about the nature or the type of analyte and/or the shape of the titration curve. The signal imperfection, as well as random noise or spikes has no influence on the operation of the procedure. The optimization of the new algorithm was done using simulated curves and next experimental data were considered. In the case of well-shaped and noise-free titration data, the proposed method gives the same accuracy and precision as commonly used algorithms. But, in the case of noisy or badly shaped curves, the presented approach works good (relative error mainly below 2% and coefficients of variability below 5%) while traditional procedures fail. Therefore, the proposed algorithm may be useful in interpretation of the experimental data and also in automation of the typical titration analysis, specially in the case when random noise interfere with analytical signal.

  7. Immersion calorimetry as a tool to evaluate the catalytic performance of titanosilicate materials in the epoxidation of cyclohexene.

    Science.gov (United States)

    Vernimmen, Jarian; Guidotti, Matteo; Silvestre-Albero, Joaquin; Jardim, Erika O; Mertens, Myrjam; Lebedev, Oleg I; Van Tendeloo, Gustaaf; Psaro, Rinaldo; Rodríguez-Reinoso, Francisco; Meynen, Vera; Cool, Pegie

    2011-04-05

    Different types of titanosilicates are synthesized, structurally characterized, and subsequently catalytically tested in the liquid-phase epoxidation of cyclohexene. The performance of three types of combined zeolitic/mesoporous materials is compared with that of widely studied Ti-grafted-MCM-41 molecular sieve and the TS-1 microporous titanosilicate. The catalytic test results are correlated with the structural characteristics of the different catalysts. Moreover, for the first time, immersion calorimetry with the same substrate molecule as in the catalytic test reaction is applied as an extra means to interpret the catalytic results. A good correlation between catalytic performance and immersion calorimetry results is found. This work points out that the combination of catalytic testing and immersion calorimetry can lead to important insights into the influence of the materials structural characteristics on catalysis. Moreover, the potential of using immersion calorimetry as a screening tool for catalysts in epoxidation reactions is shown.

  8. Determination of organic bases in non-aqueous solvents by catalytic thermometric titration.

    Science.gov (United States)

    Vajgand, V J; Kiss, T A; Gaál, F F; Zsigrai, I J

    1968-07-01

    Catalytic thermometric titrations have been developed for bases (brucine, diethylaniline, potassium acetate and triethylamine) in acetic acid by continuous and discontinuous addition of the standard solution and automatic temperature recording. The determination of weak bases, e.g., antipyrine, unsuccessful in acetic acid by catalytic thermometric titration, has been achieved by using nitromethane or acetic anhydride as solvent. Catalytic thermometric titrations were also performed by coulometric generation of hydrogen ions for the determination of micro amounts of weak bases in a mixture of acetic anhyride and acetic acid.

  9. Simple modification of karl-Fischer titration method for determination of water content in colored samples.

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R(2) = 0.997).

  10. Linear regression analysis of potentiometric titration data for asymmetric redox reactions

    International Nuclear Information System (INIS)

    Mar'yanov, B.M.; Gavrilenko, M.A.

    1997-01-01

    A statistical method of processing the curves of potentiometric titration for homogeneous asymmetric redox reactions has been suggested. The method was tested using a model titrimetric system Mohr's salt-K 2 Cr 2 O 7 and was employed for Te determination in an individual solution, semiconductor alloy and CdTe ceramics. Random error of the equivalence point evaluation by the data of a specific titration of 0.1-0.01 M solutions does not exceed 0.3% in case of titration of 0.001 M solutions it increases up to 1.2%. The value of s r varies from 0.0006 to 0.007

  11. Synthesis and binding affinity analysis of α1-2- and α1-6-O/S-linked dimannosides for the elucidation of sulfur in glycosidic bonds using quartz crystal microbalance sensors

    DEFF Research Database (Denmark)

    Norberg, Oscar; Wu, Bin; Thota, Niranjan

    2017-01-01

    with the cognate lectin concanavalin A. Mannose-presenting QCM sensors were produced using photoinitiated, nitrene-mediated immobilization methods, and the subsequent binding study was performed in an automated flow-through instrumentation, and correlated with data from isothermal titration calorimetry...

  12. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    Science.gov (United States)

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  13. Determination of free acid in U(VI)-Al(III) solution by Gran plot titration

    International Nuclear Information System (INIS)

    Suh, Moo Yul; Lee, Chang Heon; Sohn, Se Chul; Kim, Jung Suk; Kim, Won Ho; Eom, Tae Yoon

    1999-01-01

    The determination method of free acid in spent U-Al nuclear fuel solutions by Gran plot titration was described. Effect of U(VI) and Al(III) on the alkalimetric titration of nitric acid was investigation in oxalate complexing media as well as in noncomplexing media. Positive biases were observed in both titration media when the end-point was estimated by the Gran plot method. It was found that the cause of the bias was U(VI) in the oxalate complexing media, but Al(III) in the noncomplexing media. The relative error was less than 1% in the titration of 0.1 M HNO 3 at a U(VI):Al(III):H + mole ratio of up to 2:12:1 as long as the pH of the oxalate titration media was sustained to be below 5.0 at the beginning of titration. The method was successfully applied to the determination of nitric acid in a solution of HANARO reactor fuel with U:Al mole ratio of 1:6

  14. A microcomputer-controlled system for titration analysis

    NARCIS (Netherlands)

    Boelema, Gerrit Jan

    1982-01-01

    This thesis deals with the results of the implementation of microprocessor technology in automatic titration equipment to obtain a versatile system for pharmaceutical, chemical analytical and optimization research purposes. ... Zie: Summary

  15. Feasibility and Association of Neurohumoral Blocker Up-titration After Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Martens, Pieter; Verbrugge, Frederik H; Nijst, Petra; Bertrand, Philippe B; Dupont, Matthias; Tang, Wilson H; Mullens, Wilfried

    2017-08-01

    Cardiac resynchronization therapy (CRT) improves mortality and morbidity on top of optimal medical therapy in heart failure with reduced ejection fraction (HFrEF). This study aimed to elucidate the association between neurohumoral blocker up-titration after CRT implantation and clinical outcomes. Doses of angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), and beta-blockers were retrospectively evaluated in 650 consecutive CRT patients implanted from October 2008 to August 2015 and followed in a tertiary multidisciplinary CRT clinic. All 650 CRT patients were on a maximal tolerable dose of ACE-I/ARB and beta-blocker at the time of CRT implantation. However, further up-titration was successful in 45.4% for ACE-I/ARB and in 56.8% for beta-blocker after CRT-implantation. During a mean follow-up of 37 ± 22 months, a total of 139 events occurred for the combined end point of heart failure admission and all-cause mortality. Successful, versus unsuccessful, up-titration was associated with adjusted hazard ratios of 0.537 (95% confidence interval 0.316-0.913; P = .022) for ACE-I/ARB and 0.633 (0.406-0.988; P = .044) for beta-blocker on the combined end point heart failure admission and all-cause mortality. Patients in the up-titration group exhibited a similar risk for death or heart failure admission as patients treated with the maximal dose (ACE-I/ARB: P = .133; beta-blockers: P = .709). After CRT, a majority of patients are capable of tolerating higher dosages of neurohumoral blockers. Up-titration of neurohumoral blockers after CRT implantation is associated with improved clinical outcomes, similarly to patients treated with the guideline-recommended target dose at the time of CRT implantation. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Extensive studies on CeF{sub 3} crystals, a good candidate for electromagnetic calorimetry at future accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Auffray, E.; Baccaro, S.; Beckers, T.; Benhammou, Y.; Belsky, A.N.; Borgia, B.; Boutet, D.; Chipaux, R.; Dafinei, I.; De Notaristefani, F.; Depasse, P.; Dujardin, C.; El Mamouni, H.; Faure, J.L.; Fay, J.; Goyot, M.; Gupta, S.K.; Gurtu, A.; Hillemanns, H.; Ille, B.; Kirn, T.; Lebeau, M.; Lebrun, P.; Lecoq, P.; Mares, J.A.; Martin, J.P.; Mikhailin, V.V.; Moine, B.; Nelissen, J.; Nikl, M.; Pedrini, C.; Raghavan, R.; Sahuc, P.; Schmitz, D.; Schneegans, M.; Schwenke, J.; Tavernier, S.; Topa, V.; Vasil`ev, A.N.; Vivargent, M.; Walder, J.P. [CERN, Geneva (Switzerland)]|[ENEA Casaccia, INFN Rome, Rome (Italy)]|[VUB, Vrije Universiteit Brussels, Brussels (Belgium)]|[IPN of Lyon, IN2P3-CNRS and Universite Claude Bernard, Villeurbanne (France)]|[Synchrotron Radiation Laboratory, Moscow State University, Moscow (Russian Federation)]|[INFN Rome, Rome (Italy)]|[LPCML of Lyon, CNRS and Universite Claude Bernard, Villeurbanne (France)]|[CEA DSM/DAPNIA, CE-Saclay (France)]|[Tara Institute of Fundamental Research, Bombay (India)]|[Physics Institute, RWTH Aachen, Aachen (Germany)]|[LAPP, IN2P3-CNRS, Annecy-le-Vieux (France)]|[Institute of Physics, Academy of Sciences of Czech Republic, Prague (Czech Republic)]|[Institute of Atomic Physics (IFA), Bucharest (Romania)

    1996-12-11

    In the framework of its search for new heavy, fast and radiation hard scintillators for calorimetry at future colliders, the Crystal Clear Collaboration performed a systematic investigation of the properties and of the scintillation and radiation damage mechanisms of CeF{sub 3} monocrystals. Many samples of various dimensions up to 3 x 3 x 28 cm{sup 3} were produced by industry and characterised in the laboratories by different methods such as: optical transmission, light yield and decay time measurements, excitation and emission spectra, gamma and neutron irradiations. The results of these measurements are discussed. The measured light yield is compared to the theoretical expectations. Tests in high energy electron beams on a crystal matrix were also performed. The suitability of CeF{sub 3} for calorimetry at high rate machines is confirmed. Production and economical considerations are discussed. (orig.).

  17. Protocol adherence for continuously titrated interventions in randomized trials: an overview of the current methodology and case study

    Directory of Open Access Journals (Sweden)

    F. Lauzier

    2017-07-01

    Full Text Available Abstract Background The standard definition for protocol adherence is the proportion of all scheduled doses that are delivered. In clinical research, this definition has several limitations when evaluating protocol adherence in trials that study interventions requiring continuous titration. Discussion Building upon a specific case study, we analyzed a recent trial of a continuously titrated intervention to assess the impact of different definitions of protocol deviations on the interpretation of protocol adherence. The OVATION pilot trial was an open-label randomized controlled trial of higher (75–80 mmHg versus lower (60–65 mmHg mean arterial pressure (MAP targets for vasopressor therapy in shock. In this trial, potential protocol deviations were defined as MAP values outside the targeted range for >4 consecutive hours during vasopressor therapy without synchronous and consistent adjustments of vasopressor doses. An adjudication committee reviewed each potential deviation to determine if it was clinically-justified or not. There are four reasons for this contextual measurement and reporting of protocol adherence. First, between-arm separation is a robust measure of adherence to complex protocols. Second, adherence assessed by protocol deviations varies in function of the definition of deviations and the frequency of measurements. Third, distinguishing clinically-justified vs. not clinically-justified protocol deviations acknowledges clinically sensible bedside decision-making and offers a clear terminology before the trial begins. Finally, multiple metrics exist to report protocol deviations, which provides different information but complementary information on protocol adherence. Conclusions In trials of interventions requiring continuous titration, metrics used for defining protocol deviations have a considerable impact on the interpretation of protocol adherence. Definitions for protocol deviations should be prespecified and correlated

  18. Determination of thermodynamic parameters for complexation of calcium and magnesium with chondroitin sulfate isomers using isothermal titration calorimetry: Implications for calcium kidney-stone research

    Science.gov (United States)

    Rodgers, Allen L.; Jackson, Graham E.

    2017-04-01

    Chondroitin sulfate (CS) occurs in human urine. It has several potential binding sites for calcium and as such may play an inhibitory role in calcium oxalate and calcium phosphate (kidney stone disease by reducing the supersaturation (SS) and crystallization of these salts. Urinary magnesium is also a role player in determining speciation in stone forming processes. This study was undertaken to determine the thermodynamic parameters for binding of the disaccharide unit of two different CS isomers with calcium and magnesium. These included the binding constant K. Experiments were performed using an isothermal titration calorimeter (ITC) at 3 different pH levels in the physiological range in human urine. Data showed that interactions between the CS isomers and calcium and magnesium occur via one binding site, thought to be sulfate, and that log K values are 1.17-1.93 and 1.77-1.80 for these two metals respectively. Binding was significantly stronger in Mg-CS than in Ca-CS complexes and was found to be dependent on pH in the latter but not in the former. Furthermore, binding in Ca-CS complexes was dependent on the location of the sulfate binding site. This was not the case in the Mg-CS complexes. Interactions were shown to be entropy driven and enthalpy unfavourable. These findings can be used in computational modeling studies to predict the effects of the calcium and magnesium CS complexes on the speciation of calcium and the SS of calcium salts in real urine samples.

  19. Hydrolysis-precipitation studies of aluminum (III) solutions. I. Titration of acidified aluminum nitrate solutions

    NARCIS (Netherlands)

    Vermeulen, A.C.; Geus, John W.; Stol, R.J.; Bruyn, P.L. de

    Acidified aluminum nitrate solutions were titrated with alkali (NaOH or KOH) over a temperature range of 24°C to 90°C. A homogeneous distribution of added base was achieved by: (i) in situ decomposition of urea (90°C); and (ii) a novel method involving injection through a capillary submerged in the

  20. Thermodynamics of ligand binding to acyl-coenzyme A binding protein studied by titration calorimetry

    DEFF Research Database (Denmark)

    Færgeman, Nils J.; Sigurskjold, B W; Kragelund, B B

    1996-01-01

    Ligand binding to recombinant bovine acyl-CoA binding protein (ACBP) was examined using isothermal microcalorimetry. Microcalorimetric measurements confirm that the binding affinity of acyl-CoA esters for ACBP is strongly dependent on the length of the acyl chain with a clear preference for acyl-...

  1. Titratable acidity of beverages influences salivary pH recovery.

    Science.gov (United States)

    Tenuta, Livia Maria Andaló; Fernández, Constanza Estefany; Brandão, Ana Carolina Siqueira; Cury, Jaime Aparecido

    2015-01-01

    A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control) were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively) and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and pH 5.5, respectively). Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  2. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  3. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Directory of Open Access Journals (Sweden)

    Eva Tavčar

    2012-01-01

    Full Text Available The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD=4.3%, accuracy, and linearity (2=0.997.

  4. Determination of trace amounts of thorium and lanthanides by successive titrations using semi-xylenol orange with spectrophotometric end-point indication

    International Nuclear Information System (INIS)

    Hafez, M.A.E.; Abdallah, A.M.A.; El-Gany, N.E.A.

    1990-01-01

    The precision and accuracy attainable in successive titrations of Th 4+ and either La 3+ , Nd 3+ or Gd 3+ with a 0.001 M solution of disodium ethylenediaminetetraacetate using Semi-xylenol Orange (SXO) as a metallochromic indicator were studied. Thorium (IV) was titrated at pH 2, the pH was adjusted to 5.5-5.9 by adding hexamethylenetetramine buffer and La 3+ (or Nd 3+ or Gd 3+ ) was then titrated. A comparison of the indicators SXO and Xylenol Orange for successive titrations of Th 4+ and either La 3+ , Nd 3+ or Gd 3+ was carried out. (author)

  5. An RCT Investigating Patient-Driven Versus Physician-Driven Titration of BIAsp 30 in Patients with Type 2 Diabetes Uncontrolled Using NPH Insulin.

    Science.gov (United States)

    Chraibi, Abdelmjid; Al-Herz, Shoorook; Nguyen, Bich Dao; Soeatmadji, Djoko W; Shinde, Anil; Lakshmivenkataraman, Balasubramanian; Assaad-Khalil, Samir H

    2017-08-01

    The aim of this study was to confirm the efficacy of patient-driven titration of BIAsp 30 in terms of glycemic control, by comparing it to physician-driven titration of BIAsp 30, in patients with type 2 diabetes in North Africa, the Middle East, and Asia. A 20-week, open-label, randomized, two-armed, parallel-group, multicenter study in Egypt, Indonesia, Morocco, Saudi Arabia, and Vietnam. Patients (n = 155) with type 2 diabetes inadequately controlled using neutral protamine Hagedorn (NPH) insulin were randomized to either patient-driven or physician-driven BIAsp 30 titration. The noninferiority of patient-driven compared to physician-driven titration with respect to the reduction in HbA1c was confirmed. The estimated mean change in HbA1c from baseline to week 20 was -1.27% in the patient-driven arm and -1.04% in the physician-driven arm, with an estimated treatment difference of -0.23% (95% confidence interval: -0.54; 0.08). After 20 weeks of treatment, the proportions of patients achieving the target of HbA1c titration arms; the proportions of patients achieving the target of ≤6.5% were also similar. Both titration algorithms were well tolerated, and hypoglycemic episode rates were similar in both arms. Patient-driven titration of BIAsp 30 can be as effective and safe as physician-driven titration in non-Western populations. Overall, the switch from NPH insulin to BIAsp 30 was well tolerated in both titration arms and led to improved glycemic control. A limitation of the study was the relatively small number of patients recruited in each country. ClinicalTrials.gov NCT01589653. Novo Nordisk A/S, Denmark.

  6. Water calorimetry: The heat defect

    International Nuclear Information System (INIS)

    Klassen, N.V.; Ross, C.K.

    1997-01-01

    Domen developed a sealed water calorimeter at NIST to measure absorbed dose to water from ionizing radiation. This calorimeter exhibited anomalous behavior using water saturated with gas mixtures of H 2 O 2 . Using computer simulations of the radiolysis of water, the authors show that the observed behavior can be explained if, in the gas mixtures, the amount-of-substance of H 2 and of O 2 differed significantly from 50%. The authors also report the results of simulations for other dilute aqueous solutions that are used for water calorimetry--pure water, air-saturated water, and H 2 -saturated water. The production of H 2 O 2 was measured for these aqueous solutions and compared to simulations. The results indicate that water saturated with a gas mixture containing an amount-of-substance of H 2 of 50% and of O 2 of 50% is suitable for water calorimetry if the water is stirred and is in contact with a gas space of similar volume. H 2 -saturated water does not require a gas space but O 2 contamination must be guarded against. The lack of a scavenger for OH radicals in pure water means that, depending on the water purity, some pure water might require a large priming dose to remove reactive impurities. The experimental and theoretical problems associated with air-saturated water and O 2 -saturated water in water calorimeters are discussed

  7. Influence of kinetics on the determination of the surface reactivity of oxide suspensions by acid-base titration.

    Science.gov (United States)

    Duc, M; Adekola, F; Lefèvre, G; Fédoroff, M

    2006-11-01

    The effect of acid-base titration protocol and speed on pH measurement and surface charge calculation was studied on suspensions of gamma-alumina, hematite, goethite, and silica, whose size and porosity have been well characterized. The titration protocol has an important effect on surface charge calculation as well as on acid-base constants obtained by fitting of the titration curves. Variations of pH versus time after addition of acid or base to the suspension were interpreted as diffusion processes. Resulting apparent diffusion coefficients depend on the nature of the oxide and on its porosity.

  8. Further investigation on the degree of deacetylation of chitosan determined by potentiometric titration

    OpenAIRE

    Kamal Sweidan; Abdel-Motalleb Jaber; Nawzat Al-jbour; Rana Obaidat; Mayyas Al- Remawi; Adnan Badwan

    2011-01-01

    The degree of deacetylation (DDA) of various low molecular weight chitosan (LMWC) species as the hydrochloride and free base (amine form) was determined by direct and back potentiometric titration, respectively. The DDA values obtained for the chitosan hydrochloride by direct titration were greater than 93% for all oligomers tested (Molecular weight (Mwt) between about 1.3 to 30.0 kDa). However, the DDA values obtained for chitosan amine oligomers using back titration were significantly lower...

  9. Evaluation of modified boehm titration methods for use with biochars.

    Science.gov (United States)

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  10. Acid-base titrations by stepwise addition of equal volumes of titrant with special reference to automatic titrations-II Theory of titration of mixtures of acids, polyprotic acids, acids in mixture with weak bases, and ampholytes.

    Science.gov (United States)

    Pehrsson, L; Ingman, F; Johansson, S

    A general method for evaluating titration data for mixtures of acids and for acids in mixture with weak bases is presented. Procedures are given that do not require absolute [H]-data, i.e., relative [H]-data may be used. In most cases a very rough calibration of the electrode system is enough. Further, for simple systems, very approximate values of the stability constants are sufficient. As examples, the titration of the following are treated in some detail: a mixture of two acids, a diprotic acid, an acid in presence of its conjugate base, and an ampholyte.

  11. A brief survey of patients' first impression after CPAP titration predicts future CPAP adherence: a pilot study.

    Science.gov (United States)

    Balachandran, Jay S; Yu, Xiaohong; Wroblewski, Kristen; Mokhlesi, Babak

    2013-03-15

    CPAP adherence patterns are often established very early in the course of therapy. Our objective was to quantify patients' perception of CPAP therapy using a 6-item questionnaire administered in the morning following CPAP titration. We hypothesized that questionnaire responses would independently predict CPAP adherence during the first 30 days of therapy. We retrospectively reviewed the CPAP perception questionnaires of 403 CPAP-naïve adults who underwent in-laboratory titration and who had daily CPAP adherence data available for the first 30 days of therapy. Responses to the CPAP perception questionnaire were analyzed for their association with mean CPAP adherence and with changes in daily CPAP adherence over 30 days. Patients were aged 52 ± 14 years, 53% were women, 54% were African American, the mean body mass index (BMI) was 36.3 ± 9.1 kg/m(2), and most patients had moderate-severe OSA. Four of 6 items from the CPAP perception questionnaire- regarding difficulty tolerating CPAP, discomfort with CPAP pressure, likelihood of wearing CPAP, and perceived health benefit-were significantly correlated with mean 30-day CPAP adherence, and a composite score from these 4 questions was found to be internally consistent. Stepwise linear regression modeling demonstrated that 3 variables were significant and independent predictors of reduced mean CPAP adherence: worse score on the 4-item questionnaire, African American race, and non-sleep specialist ordering polysomnogram and CPAP therapy. Furthermore, a worse score on the 4-item CPAP perception questionnaire was consistently associated with decreased mean daily CPAP adherence over the first 30 days of therapy. In this pilot study, responses to a 4-item CPAP perception questionnaire administered to patients immediately following CPAP titration independently predicted mean CPAP adherence during the first 30 days. Further prospective validation of this questionnaire in different patient populations is warranted.

  12. Fast sampling calorimetry with solid argon ionization chambers

    International Nuclear Information System (INIS)

    Clark, E.; Linn, S.; Piekarz, H.; Wahl, H.; Womersley, J.; Hansen, S.; Hurh, P.; Rivetta, C.; Sanders, R.; Schmitt, R.; Stanek, R.; Stefanik, A.

    1992-01-01

    A proposal for the fast sampling calorimetry with solid argon as active medium and the preliminary results from the solid argon test cell are presented. The proposed test calorimeter module structure, the signal routing and the mechanical and cryogenic arrangements are also discussed

  13. A study of the growth for the microalga Chlorella vulgaris by photo-bio-calorimetry and other on-line and off-line techniques

    NARCIS (Netherlands)

    Patino, R.; Janssen, M.G.J.; Stockar, von U.

    2007-01-01

    Calorimetry and other on-line techniques are used for the first time as complement to the traditional off-line methods in order to follow the growth of the green Chlorella vulgaris microalgae. A 2-L photo-bio-reactor was adapted from a commercial calorimeter used previously to study heterotrophic

  14. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    OpenAIRE

    Lorentz JÄNTSCHI; Horea Iustin NAŞCU

    2002-01-01

    The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titra...

  15. Hydrogen Bonding in Phosphine Oxide/Phosphate-Phenol Complexes

    NARCIS (Netherlands)

    Cuypers, R.; Sudhölter, E.J.R.; Zuilhof, H.

    2010-01-01

    To develop a new solvent-impregnated resin (SIR) system for the removal of phenols and thiophenols from water, complex formation by hydrogen bonding of phosphine oxides and phosphates is studied using isothermal titration calorimetry (ITC) and quantum chemical modeling. Six different computational

  16. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  17. Evaluation of the 5 and 8 pH point titration methods for monitoring anaerobic digesters treating solid waste.

    Science.gov (United States)

    Vannecke, T P W; Lampens, D R A; Ekama, G A; Volcke, E I P

    2015-01-01

    Simple titration methods certainly deserve consideration for on-site routine monitoring of volatile fatty acid (VFA) concentration and alkalinity during anaerobic digestion (AD), because of their simplicity, speed and cost-effectiveness. In this study, the 5 and 8 pH point titration methods for measuring the VFA concentration and carbonate system alkalinity (H2CO3*-alkalinity) were assessed and compared. For this purpose, synthetic solutions with known H2CO3*-alkalinity and VFA concentration as well as samples from anaerobic digesters treating three different kind of solid wastes were analysed. The results of these two related titration methods were verified with photometric and high-pressure liquid chromatography measurements. It was shown that photometric measurements lead to overestimations of the VFA concentration in the case of coloured samples. In contrast, the 5 pH point titration method provides an accurate estimation of the VFA concentration, clearly corresponding with the true value. Concerning the H2CO3*-alkalinity, the most accurate and precise estimations, showing very similar results for repeated measurements, were obtained using the 8 pH point titration. Overall, it was concluded that the 5 pH point titration method is the preferred method for the practical monitoring of AD of solid wastes due to its robustness, cost efficiency and user-friendliness.

  18. Conductimetric and Potentiometric Titration of Some Hydroxylated Cinnamic Acids with Tetrabutylammonium Hydroxide in Non-Aqueous Media

    OpenAIRE

    AKTAŞ, A. Hakan; YAŞAR, Gülsüm; ALSANCAK, Güleren ÖZKAN

    2001-01-01

    In this study, four hydroxycinnamic acids, namely 3,4-dihydroxycinnamic acid, 4-hydroxycinnamic acid, 4-hydroxy --3- methoxycinnamic acid and 4-hydroxy-3,5-dimethoxycinnamic acid, were titrated conductimetrically and potentiometrically using triethylamine and tetrabutylammonium hydroxide in acetonitrile, 2-propanol, and pyridine solvents under a nitrogen atmosphere at 25 oC. In conductimetric titration with tetrabutylammonium hydroxide all of the compounds exhibited conventional s...

  19. A 24-Week, Randomized, Controlled Study to Evaluate the Tolerability, Safety and Efficacy of 2 Different Titration Schemes of the Rivastigmine Patch in Japanese Patients with Mild to Moderate Alzheimer's Disease

    Directory of Open Access Journals (Sweden)

    Yu Nakamura

    2015-09-01

    Full Text Available Aim: To investigate whether 1-step titration of the rivastigmine patch (initiated at 5 cm2 and titrated to 10 cm2 after 4 weeks is well tolerated in Japanese patients with Alzheimer's disease (AD as compared to 3-step titration (initiated at 2.5 cm2 and titrated by 2.5 cm2 every 4 weeks to 10 cm2. Methods: A 24-week, multicenter, randomized, double-blind study was conducted in Japan between July 2012 and May 2014. Patients with mild to moderate AD aged 50-85 years were randomized 1:1 to 1-step or 3-step titration of the rivastigmine once-daily patch. The primary endpoint was the proportion of patients with adverse events leading to discontinuation. Results: Of 216 patients randomized, 215 (1-step, n = 107; 3-step, n = 108 were included in the safety analysis. The primary endpoint outcome was 15.0% in the 1-step group and 18.5% in the 3-step group. The observed treatment difference was −3.6% (95% confidence interval: −17.0, 9.6, falling within the prespecified acceptance range. Conclusion: The tolerability of two different titration schemes was similar in Japanese patients with AD.

  20. Titration Calculations with Computer Algebra Software

    Science.gov (United States)

    Lachance, Russ; Biaglow, Andrew

    2012-01-01

    This article examines the symbolic algebraic solution of the titration equations for a diprotic acid, as obtained using "Mathematica," "Maple," and "Mathcad." The equilibrium and conservation equations are solved symbolically by the programs to eliminate the approximations that normally would be performed by the student. Of the three programs,…

  1. Binding of the biogenic polyamines to deoxyribonucleic acids of varying base composition: base specificity and the associated energetics of the interaction.

    Science.gov (United States)

    Kabir, Ayesha; Suresh Kumar, Gopinatha

    2013-01-01

    The thermodynamics of the base pair specificity of the binding of the polyamines spermine, spermidine, putrescine, and cadaverine with three genomic DNAs Clostridium perfringens, 27% GC, Escherichia coli, 50% GC and Micrococcus lysodeikticus, 72% GC have been studied using titration calorimetry and the data supplemented with melting studies, ethidium displacement and circular dichroism spectroscopy results. Isothermal titration calorimetry, differential scanning calorimetry, optical melting studies, ethidium displacement, circular dichroism spectroscopy are the various techniques employed to characterize the interaction of four polyamines, spermine, spermidine, putersine and cadaverine with the DNAs. Polyamines bound stronger with AT rich DNA compared to the GC rich DNA and the binding varied depending on the charge on the polyamine as spermine>spermidine >putrescine>cadaverine. Thermodynamics of the interaction revealed that the binding was entropy driven with small enthalpy contribution. The binding was influenced by salt concentration suggesting the contribution from electrostatic forces to the Gibbs energy of binding to be the dominant contributor. Each system studied exhibited enthalpy-entropy compensation. The negative heat capacity changes suggested a role for hydrophobic interactions which may arise due to the non polar interactions between DNA and polyamines. From a thermodynamic analysis, the AT base specificity of polyamines to DNAs has been elucidated for the first time and supplemented by structural studies.

  2. Potentiometric titrations of para and nitro substituted aromatic acids and their mixtures in methylethyl ketone

    International Nuclear Information System (INIS)

    Ozeroglu, C.; Karahan, M.

    2011-01-01

    In this study, it was the purpose to examine the potentiometric titrations of para and nitro substituted aromatic acids in methylethyl ketone (MEK) as a non-aqueous solvent. Good analytical results were obtained in determining the amount of each acid and the amounts of acids in their ternary mixtures by using 0.0964 N tetrabuthylammoniumhydroxyde (TBAH) as a standard titrant. Methylethyl ketone (MEK) which is a good solvent for many organic compounds and has a convenient liquid range of -86 to 80 deg. C was used for titration of the para and nitro substituted aromatic acids. A linear relationship has been found between pKa values of the para and nitro substituted aromatic acids in water and the half neutralization potential (HNP) values determined by potentiometric titration curves of the same acids in MEK. (author)

  3. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    Energy Technology Data Exchange (ETDEWEB)

    Pesavento, Maria; Profumo, Antonella; Biesuz, Raffaela

    1987-09-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO/sub 3/-,I+,1/sub 2/ or I-) and a mixture, and is equal to 2 x 10/sup -7/ M. Chloride and bromide, even at very high concentrations, do not interfere.

  4. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    International Nuclear Information System (INIS)

    Pesavento, Maria; Profumo, Antonella

    1987-01-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO 3 -,I+,1 2 or I-) and a mixture, and is equal to 2 x 10 -7 M. Chloride and bromide, even at very high concentrations, do not interfere. (author)

  5. Thermometric titration of cadmium with sodium diethyldithiocarbamate, with oxidation by hydrogen peroxide as indicator reaction.

    Science.gov (United States)

    Hattori, T; Yoshida, H

    1987-08-01

    A new method of end-point indication is described for thermometric titration of cadmium with sodium diethyldithiocarbamate (DDTC). It is based on the redox reaction between hydrogen peroxide added to the system before titration, and the first excess of DDTC. Amounts of cadmium in the range 10-50 mumoles are titrated within 1% error.

  6. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    Science.gov (United States)

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  7. Irreversible denaturation of maltodextrin glucosidase studied by differential scanning calorimetry, circular dichroism, and turbidity measurements.

    Science.gov (United States)

    Goyal, Megha; Chaudhuri, Tapan K; Kuwajima, Kunihiro

    2014-01-01

    Thermal denaturation of Escherichia coli maltodextrin glucosidase was studied by differential scanning calorimetry, circular dichroism (230 nm), and UV-absorption measurements (340 nm), which were respectively used to monitor heat absorption, conformational unfolding, and the production of solution turbidity. The denaturation was irreversible, and the thermal transition recorded at scan rates of 0.5-1.5 K/min was significantly scan-rate dependent, indicating that the thermal denaturation was kinetically controlled. The absence of a protein-concentration effect on the thermal transition indicated that the denaturation was rate-limited by a mono-molecular process. From the analysis of the calorimetric thermograms, a one-step irreversible model well represented the thermal denaturation of the protein. The calorimetrically observed thermal transitions showed excellent coincidence with the turbidity transitions monitored by UV-absorption as well as with the unfolding transitions monitored by circular dichroism. The thermal denaturation of the protein was thus rate-limited by conformational unfolding, which was followed by a rapid irreversible formation of aggregates that produced the solution turbidity. It is thus important to note that the absence of the protein-concentration effect on the irreversible thermal denaturation does not necessarily means the absence of protein aggregation itself. The turbidity measurements together with differential scanning calorimetry in the irreversible thermal denaturation of the protein provided a very effective approach for understanding the mechanisms of the irreversible denaturation. The Arrhenius-equation parameters obtained from analysis of the thermal denaturation were compared with those of other proteins that have been reported to show the one-step irreversible thermal denaturation. Maltodextrin glucosidase had sufficiently high kinetic stability with a half-life of 68 days at a physiological temperature (37°C).

  8. Titratable acidity of beverages influences salivary pH recovery

    Directory of Open Access Journals (Sweden)

    Livia Maria Andaló TENUTA

    2015-01-01

    Full Text Available A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and < 0.005 mmols OH- to reach pH 5.5, respectively. Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  9. [A double antibody sandwich ELISA based assay for titration of severe fever with thrombocytopenia syndrome virus].

    Science.gov (United States)

    Liu, Lin; Zhang, Quan-Fu; Li, Chuan; Li, Jian-Dong; Jiang, Xiao-Lin; Zhang, Fu-Shun; Wu, Wei; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    To develop an assay for titration of severe fever with thrombocytopenia syndrome virus (SFTSV) based on double antibody sandwich ELISA. A double antibody sandwich ELISA was developed for detection of SFTSV based on SFTSV nucleocapsid (N) protein specific poly- and monoclonal antibodies, procedures were optimized and evaluated. This ELISA based titration assay was compared with fluorescence assasy and plaque assay based titration method. The results suggested that the titers obtained by ELISA based method are consistent with those obtained by IFA based method (R = 0.999) and the plaque assay titration method (R = 0.949). The novel ELISA based titration method with high sensitivity and specificity is easy to manage and perform, and can overcome the subjectivity associated with result determination of the fluorescence assay and plaque assay based methods. The novel ELISA based titration method can also be applied to high throughput detection.

  10. Optical calorimetry in microfluidic droplets.

    Science.gov (United States)

    Chamoun, Jacob; Pattekar, Ashish; Afshinmanesh, Farzaneh; Martini, Joerg; Recht, Michael I

    2018-05-29

    A novel microfluidic calorimeter that measures the enthalpy change of reactions occurring in 100 μm diameter aqueous droplets in fluoropolymer oil has been developed. The aqueous reactants flow into a microfluidic droplet generation chip in separate fluidic channels, limiting contact between the streams until immediately before they form the droplet. The diffusion-driven mixing of reactants is predominantly restricted to within the droplet. The temperature change in droplets due to the heat of reaction is measured optically by recording the reflectance spectra of encapsulated thermochromic liquid crystals (TLC) that are added to one of the reactant streams. As the droplets travel through the channel, the spectral characteristics of the TLC represent the internal temperature, allowing optical measurement with a precision of ≈6 mK. The microfluidic chip and all fluids are temperature controlled, and the reaction heat within droplets raises their temperature until thermal diffusion dissipates the heat into the surrounding oil and chip walls. Position resolved optical temperature measurement of the droplets allows calculation of the heat of reaction by analyzing the droplet temperature profile over time. Channel dimensions, droplet generation rate, droplet size, reactant stream flows and oil flow rate are carefully balanced to provide rapid diffusional mixing of reactants compared to thermal diffusion, while avoiding thermal "quenching" due to contact between the droplets and the chip walls. Compared to conventional microcalorimetry, which has been used in this work to provide reference measurements, this new continuous flow droplet calorimeter has the potential to perform titrations ≈1000-fold faster while using ≈400-fold less reactants per titration.

  11. Thermodynamic and kinetic aspects of coassembly of PEO-PMAA block copolymer and DPCl surfactants into ordered nanoparticles in aqueous solutions studied by ITC, NMR, and time-resolved SAXS techniques

    Czech Academy of Sciences Publication Activity Database

    Uchman, M.; Gradzielski, M.; Angelov, Borislav; Tošner, Z.; Oh, J.; Chang, T.; Štěpánek, M.; Procházka, K.

    2013-01-01

    Roč. 46, č. 6 (2013), s. 2172-2181 ISSN 0024-9297 R&D Projects: GA ČR GAP208/10/0353; GA ČR GCP205/11/J043 Institutional support: RVO:61389013 Keywords : isothermal titration calorimetry * SAXS * soft matter Subject RIV: CD - Macromolecular Chemistry Impact factor: 5.927, year: 2013

  12. A stable and convenient protein electrophoresis titration device with bubble removing system.

    Science.gov (United States)

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Data processing for potentiometric precipitation titration of mixtures of isovalent ions by linear regression analysis

    International Nuclear Information System (INIS)

    Mar'yanov, B.M.; Shumar, S.V.; Gavrilenko, M.A.

    1994-01-01

    A method for the computer processing of the curves of potentiometric differential titration using the precipitation reactions is developed. This method is based on transformation of the titration curve into a line of multiphase regression, whose parameters determine the equivalence points and the solubility products of the formed precipitates. The computational algorithm is tested using experimental curves for the titration of solutions containing Hg(2) and Cd(2) by the solution of sodium diethyldithiocarbamate. The random errors (RSD) for the titration of 1x10 -4 M solutions are in the range of 3-6%. 7 refs.; 2 figs.; 1 tab

  14. Number of independent parameters in the potentiometric titration of humic substances.

    Science.gov (United States)

    Lenoir, Thomas; Manceau, Alain

    2010-03-16

    With the advent of high-precision automatic titrators operating in pH stat mode, measuring the mass balance of protons in solid-solution mixtures against the pH of natural and synthetic polyelectrolytes is now routine. However, titration curves of complex molecules typically lack obvious inflection points, which complicates their analysis despite the high-precision measurements. The calculation of site densities and median proton affinity constants (pK) from such data can lead to considerable covariance between fit parameters. Knowing the number of independent parameters that can be freely varied during the least-squares minimization of a model fit to titration data is necessary to improve the model's applicability. This number was calculated for natural organic matter by applying principal component analysis (PCA) to a reference data set of 47 independent titration curves from fulvic and humic acids measured at I = 0.1 M. The complete data set was reconstructed statistically from pH 3.5 to 9.8 with only six parameters, compared to seven or eight generally adjusted with common semi-empirical speciation models for organic matter, and explains correlations that occur with the higher number of parameters. Existing proton-binding models are not necessarily overparametrized, but instead titration data lack the sensitivity needed to quantify the full set of binding properties of humic materials. Model-independent conditional pK values can be obtained directly from the derivative of titration data, and this approach is the most conservative. The apparent proton-binding constants of the 23 fulvic acids (FA) and 24 humic acids (HA) derived from a high-quality polynomial parametrization of the data set are pK(H,COOH)(FA) = 4.18 +/- 0.21, pK(H,Ph-OH)(FA) = 9.29 +/- 0.33, pK(H,COOH)(HA) = 4.49 +/- 0.18, and pK(H,Ph-OH)(HA) = 9.29 +/- 0.38. Their values at other ionic strengths are more reliably calculated with the empirical Davies equation than any existing model fit.

  15. CALOR2012 XVth International Conference on Calorimetry in High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Akchurin, Nural .

    2015-05-04

    The International Conferences on Calorimetry in High Energy Physics, or the CALOR series, have always been where the calorimeter experts come together to review the state of calorimetry and bring forth new ideas every two years. The fteenth conference, CALOR2012, in Santa Fe was no exception. Although they were built roughly a decade ago, we are now witnessing the exceptional power of the LHC calorimeters and the crucial role they have been playing in the discovery of the 125 GeV Higgs-like boson. As we ruminate on the coming generation of experiments at the next (linear) collider and on the upgrades at the LHC, we are heartened by the substantial advances we made in calorimetry in the last decade. These advances will certainly help uncover new physics in the years to come, not only at colliders but also in astroparticle experiments that take advantage of natural elements such as air, water, and ice. The proceedings were published by the IOP in Journal of Physics, Vol 404 2011. The conference web site is calor2012.ttu.edu.

  16. Potentiometric titration of selenic and telluric acids with titanium(III) chloride in nonaqueous solvents

    International Nuclear Information System (INIS)

    Yoshimura, Chozo; Miyamoto, Kiyoshige

    1985-01-01

    Selenic and Telluric acids were titrated potentiometrically with titanium(III) chloride solution by using Pt-Cu · Hg bimetallic electrodes in nonaqueous solvents such as N, N-dimethyl-formamide (DMF), dimethyl sulfoxide (DMSO), isopropyl alcohol (IPA) and the mixtures of these solvents. It was found that selenic and telluric acids were titrated directly at room temperature in DMF solution without hydrochloric acid. The molar ratios of selenic and telluric acids to titanium(III) chloride was 1 : 6. However, the corresponding reactions to SeO 4 2- → SeO 3 2- or TeO 4 2- → TeO 3 2- were not confirmed in the titration curve in DMF. In the titration of selenic acid in mixed solvents of DMF and IPA in 1 : 1 or 1 : 2 ratio, two steps were observed. The first and the second steps were appeared on the titration curve at molar ratios of 1 : 2 and 1 : 6, respectively. It was interpreted that the first step corresponded to the intermediate reaction of SeO 4 2- → SeO 3 2- . Mixed solution of selenic and telluric acids were determined by the proposed method. Three steps were observed on the titration curve. It was interpreted that the first, second and third steps corresponded to the reaction of SeO 4 2- → SeO 3 2- , SeO 3 2- → Se(0), and TeO 4 2- → Te(0), respectively. Less than 5 % of water gave no influence on the titration. (author)

  17. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    Directory of Open Access Journals (Sweden)

    Moro M

    2016-07-01

    Full Text Available Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA, also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management.Methods: We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split night; n=306 two-night. Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI ≥5 during split PSG (SN-PSG versus full-night PSG (FN-PSG titrations.Results: CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients.Conclusion: Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the

  18. Theoretical studies of hadronic calorimetry for high luminosity, high energy colliders

    Energy Technology Data Exchange (ETDEWEB)

    Brau, J.E.; Gabriel, T.A.

    1989-01-01

    Experiments at the high luminosity, high energy colliders of the future are going to demand optimization of the state of the art of calorimetry design and construction. During the past few years, the understanding of the basic phenomenology of hadron calorimeters has advanced through paralleled theoretical and experimental investigations. The important underlying processes are reviewed to set the framework for the presentation of recent calculations of the expected performance of silicon detector based hadron calorimeters. Such devices employing uranium are expected to achieve the compensation condition (that is, e/h approx. 1.0) based on the understanding that has been derived from the uranium-liquid argon and uranium-plastic scintillator systems. In fact, even lead-silicon calorimeters are found to achieve the attractive value for the e/h ratio of 1.16 at 10 GeV. 62 refs., 22 figs., 3 tabs.

  19. Theoretical studies of hadronic calorimetry for high luminosity, high energy colliders

    International Nuclear Information System (INIS)

    Brau, J.E.; Gabriel, T.A.

    1989-01-01

    Experiments at the high luminosity, high energy colliders of the future are going to demand optimization of the state of the art of calorimetry design and construction. During the past few years, the understanding of the basic phenomenology of hadron calorimeters has advanced through paralleled theoretical and experimental investigations. The important underlying processes are reviewed to set the framework for the presentation of recent calculations of the expected performance of silicon detector based hadron calorimeters. Such devices employing uranium are expected to achieve the compensation condition (that is, e/h ∼ 1.0) based on the understanding that has been derived from the uranium-liquid argon and uranium-plastic scintillator systems. In fact, even lead-silicon calorimeters are found to achieve the attractive value for the e/h ratio of 1.16 at 10 GeV. 62 refs., 22 figs., 3 tabs

  20. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.

    Science.gov (United States)

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D

    2010-04-15

    Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations.

  1. Determination of quaternary ammonium compounds by potentiometric titration with an ionic surfactant electrode: single-laboratory validation.

    Science.gov (United States)

    Price, Randi; Wan, Ping

    2010-01-01

    A potentiometric titration for determining the quaternary ammonium compounds (QAC) commonly found in antimicrobial products was validated by a single laboratory. Traditionally, QACs were determined by using a biphasic (chloroform and water) manual titration procedure. Because of safety considerations regarding chloroform, as well as the subjectivity of color indicator-based manual titration determinations, an automatic potentiometric titration procedure was tested with quaternary nitrogen product formulations. By using the Metrohm Titrando system coupled with an ionic surfactant electrode and an Ag/AgCl reference electrode, titrations were performed with various QAC-containing formulation products/matrixes; a standard sodium lauryl sulfate solution was used as the titrant. Results for the products tested are sufficiently reproducible and accurate for the purpose of regulatory product enforcement. The robustness of the method was measured by varying pH levels, as well as by comparing buffered versus unbuffered titration systems. A quantitation range of 1-1000 ppm quaternary nitrogen was established. Eight commercially available antimicrobial products covering a variety of matrixes were assayed; the results obtained were comparable to those obtained by the manual titration method. Recoveries of 94 to 104% were obtained for spiked samples.

  2. Determination of Titratable Acidity in Wine Using Potentiometric, Conductometric, and Photometric Methods

    Science.gov (United States)

    Volmer, Dietrich A.; Curbani, Luana; Parker, Timothy A.; Garcia, Jennifer; Schultz, Linda D.; Borges, Endler Marcel

    2017-01-01

    This experiment describes a simple protocol for teaching acid-base titrations using potentiometry, conductivity, and/or photometry to determine end points without an added indicator. The chosen example examines the titratable acidity of a red wine with NaOH. Wines contain anthocyanins, the colors of which change with pH. Importantly, at the…

  3. The efficacy of three different mask styles on a PAP titration night.

    Science.gov (United States)

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Individualized toxicity-titrated 6-mercaptopurine increments during high-dose methotrexate consolidation treatment of lower risk childhood acute lymphoblastic leukaemia. A Nordic Society of Paediatric Haematology and Oncology (NOPHO) pilot study

    DEFF Research Database (Denmark)

    Frandsen, Thomas L; Abrahamsson, Jonas; Lausen, Birgitte

    2011-01-01

    This study explored the feasibility and toxicity of individualized toxicity-titrated 6-mercaptopurine (6MP) dose increments during post-remission treatment with High-dose methotrexate (HDM) (5000 mg/m(2), ×3) in 38 patients with Childhood (ALL). Patients were increased in steps of 25 mg 6MP/m(2...... the remaining patients (P = 0·03). This study shows individualized toxicity-titrated 6MP dosing during consolidation is feasible without increased risk of toxicity....

  5. Constant-pH molecular dynamics using stochastic titration

    Science.gov (United States)

    Baptista, António M.; Teixeira, Vitor H.; Soares, Cláudio M.

    2002-09-01

    A new method is proposed for performing constant-pH molecular dynamics (MD) simulations, that is, MD simulations where pH is one of the external thermodynamic parameters, like the temperature or the pressure. The protonation state of each titrable site in the solute is allowed to change during a molecular mechanics (MM) MD simulation, the new states being obtained from a combination of continuum electrostatics (CE) calculations and Monte Carlo (MC) simulation of protonation equilibrium. The coupling between the MM/MD and CE/MC algorithms is done in a way that ensures a proper Markov chain, sampling from the intended semigrand canonical distribution. This stochastic titration method is applied to succinic acid, aimed at illustrating the method and examining the choice of its adjustable parameters. The complete titration of succinic acid, using constant-pH MD simulations at different pH values, gives a clear picture of the coupling between the trans/gauche isomerization and the protonation process, making it possible to reconcile some apparently contradictory results of previous studies. The present constant-pH MD method is shown to require a moderate increase of computational cost when compared to the usual MD method.

  6. Three different up-titration regimens of ponesimod, an S1P1 receptor modulator, in healthy subjects.

    Science.gov (United States)

    Scherz, Michael W; Brossard, Patrick; D'Ambrosio, Daniele; Ipek, Murat; Dingemanse, Jasper

    2015-06-01

    Ponesimod is a selective S1P1 receptor modulator, and induces dose-dependent reduction of circulating lymphocytes upon oral dosing. Previous studies showed that single doses up to 75 mg or multiple doses up to 40 mg once daily are well tolerated, and heart rate (HR) reduction and atrio-ventricular conduction delays upon treatment initiation are reduced by gradual up-titration to the maintenance dose. This single-center, open-label, randomized, multiple-dose, 3-treatment, 3-way crossover study compared the tolerability, safety, pharmacokinetics, cardiodynamics, and effects on lymphocytes of 3 different up-titration regimens of ponesimod in healthy male and female subjects. Up-titration regimens comprised escalating periods of b.i.d. dosing (2.5 or 5 mg) and q.d. dosing (10 or 20 mg or both). After the third up-titration period a variable-duration washout period of 1-3 days was followed by re-challenge with a single 20-mg dose of ponesimod. Adverse events were transient and mild to moderate in intensity, not different between regimens. HR decrease after the first dose was greater than after all subsequent doses, including up-titration doses. Little or no HR change was observed with morning doses of b.i.d. regimens, suggesting that 2.5 and 5 mg b.i.d. are sufficient to sustain cardiac desensitization for the 12-hours dosing interval. © 2015, The American College of Clinical Pharmacology.

  7. Non-euclidean simplex optimization. [Application to potentiometric titration of Pu

    Energy Technology Data Exchange (ETDEWEB)

    Silver, G.L.

    1977-08-15

    Geometric optimization techniques useful for studying chemical equilibrium traditionally rely upon principles of euclidean geometry, but such algorithms may also be based upon principles of a non-euclidean geometry. The sequential simplex method is adapted to the hyperbolic plane, and application of optimization to problems such as the potentiometric titration of plutonium is suggested.

  8. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

    Science.gov (United States)

    Martens, Pieter; Verbrugge, Frederik H; Boonen, Levinia; Nijst, Petra; Dupont, Matthias; Mullens, Wilfried

    2018-01-01

    Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process. Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5). Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Clinical, polysomnographic, and CPAP titration features of obstructive sleep apnea: Mixed versus purely obstructive type.

    Science.gov (United States)

    Lee, Sang-Ahm; Lee, Gha-Hyun; Chung, Yoo-Sam; Kim, Woo Sung

    2015-08-15

    To determine whether obstructive sleep apnea syndrome (OSAS) patients with mixed sleep apnea (MSA) have different clinical, polysomnographic, and continuous positive airway pressure (CPAP) titration findings compared to OSAS patients without MSA. We retrospectively reviewed the records of OSAS patients who had undergone CPAP titration and categorized them into pure-OSA and mixed-OSA groups. Demographic features, daytime sleepiness, and apnea severity were compared between the two groups using univariate and multivariate analyses. CPAP titration findings were also compared between the two groups. One hundred and ninety-five subjects (n=126 pure-OSA; n=69 mixed-OSA) were included in the analysis. Compared to the pure-OSA group, the mixed-OSA group had a higher percentage of males (p=0.003) and a higher body mass index (p=0.044), Epworth Sleepiness Scale score (p=0.028), and apnea-hypopnea index (AHI) (ptitration, and a higher titrated pressure than the pure-OSA group. Severe OSA, older age, male sex, obesity, and daytime sleepiness were related to mixed-OSA. Complex sleep apnea, less optimal titration, and a higher titrated CPAP were also associated with MSA in OSAS patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Glass transition of anhydrous starch by fast scanning calorimetry.

    Science.gov (United States)

    Monnier, Xavier; Maigret, Jean-Eudes; Lourdin, Denis; Saiter, Allisson

    2017-10-01

    By means of fast scanning calorimetry, the glass transition of anhydrous amorphous starch has been measured. With a scanning rate of 2000Ks -1 , thermal degradation of starch prior to the glass transition has been inhibited. To certify the glass transition measurement, structural relaxation of the glassy state has been investigated through physical aging as well as the concept of limiting fictive temperature. In both cases, characteristic enthalpy recovery peaks related to the structural relaxation of the glass have been observed. Thermal lag corrections based on the comparison of glass transition temperatures measured by means of differential and fast scanning calorimetry have been proposed. The complementary investigations give an anhydrous amorphous starch glass transition temperature of 312±7°C. This estimation correlates with previous extrapolation performed on hydrated starches. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    Science.gov (United States)

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level

    International Nuclear Information System (INIS)

    Sahoo, P.; Ananthanarayanan, R.; Malathi, N.; Rajiniganth, M.P.; Murali, N.; Swaminathan, P.

    2010-01-01

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 μg L -1 levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L -1 levels, with modification in methodology for accurate detection of end point even at 10.0 μg L -1 levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 μg L -1 O 2 . Finally, several water samples containing dissolved oxygen from mg L -1 to μg L -1 levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 μg L -1 O 2 level is 0.14 (n = 5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 μg L -1 levels.

  13. A randomised controlled trial evaluating IGF1 titration in contrast to current GH dosing strategies in children born small for gestational age: the North European Small-for-Gestational-Age Study.

    Science.gov (United States)

    Jensen, Rikke Beck; Thankamony, Ajay; O'Connell, Susan M; Kirk, Jeremy; Donaldson, Malcolm; Ivarsson, Sten-A; Söder, Olle; Roche, Edna; Hoey, Hilary; Dunger, David B; Juul, Anders

    2014-10-01

    Short children born small for gestational age (SGA) are treated with a GH dose based on body size, but treatment may lead to high levels of IGF1. The objective was to evaluate IGF1 titration of GH dose in contrast to current dosing strategies. In the North European Small-for-Gestational-Age Study (NESGAS), 92 short pre-pubertal children born SGA were randomised after 1 year of high-dose GH treatment (67 μg/kg per day) to three different regimens: high dose (67 μg/kg per day), low dose (35 μg/kg per day) or IGF1 titration. The average dose during the second year of the randomised trial did not differ between the IGF1 titration group (38 μg/kg per day, s.d. 0.019) and the low-dose group (35 μg/kg per day, s.d. 0.002; P=0.46), but there was a wide variation in the IGF1 titration group (range 10-80 μg/kg per day). The IGF1 titration group had significantly lower height gain (0.17 SDS, s.d. 0.18) during the second year of the randomised trial compared with the high-dose group (0.46 SDS, s.d. 0.25), but not significantly lower than the low-dose group (0.23 SDS, s.d. 0.15; P=0.17). The IGF1 titration group had lower IGF1 levels after 2 years of the trial (mean 1.16, s.d. 1.24) compared with both the low-dose (mean 1.76, s.d. 1.48) and the high-dose (mean 2.97, s.d. 1.63) groups. IGF1 titration of GH dose in SGA children proved less effective than current dosing strategies. IGF1 titration resulted in physiological IGF1 levels with a wide range of GH dose and a poorer growth response, which indicates the role of IGF1 resistance and highlights the heterogeneity of short SGA children. © 2014 European Society of Endocrinology.

  14. Determination of uranium and plutonium by sequential potentiometric titration

    International Nuclear Information System (INIS)

    Kato, Yoshiharu; Takahashi, Masao

    1976-01-01

    The determination of uranium and plutonium in mixed oxide fuels has been developed by sequential potentiometric titration. A weighed sample of uranium and plutonium oxides is dissolved in a mixture of nitric and hydrofluoric acids and the solution is fumed with sulfuric acid. After the reduction of uranium and plutonium to uranium(IV) and plutonium(III) by chromium(II) sulfate, 5 ml of buffer solution (KCl-HCl, pH 1.0) is added to the solution. Then the solution is diluted to 30 ml with water and the pH of the solution is adjusted to 1.0 -- 1.5 with 1 M sodium hydroxide. The solution is stirred until the oxidation of the excess of chromium(II) by air is completed. After the removal of dissolved oxygen by bubbling nitrogen through the solution for 10 minutes, uranium (IV) is titrated with 0.1 N cerium(IV) sulfate. Then, plutonium is titrated by 0.02 N cerium(IV) sulfate. When a mixture of uranium and plutonium is titrated with 0.1 N potassium dichromate potentiometrically, the potential change at the end point of plutonium is very small and the end point of uranium is also unclear when 0.1 N potassium permanganate is used as a titrant. In the present method, nitrate, fluoride and copper(II) interfere with the determination of plutonium and uranium. Iron interferes quantitatively with the determination of plutonium but not of uranium. Results obtained in applying the proposed method to 50 mg of mixtures of plutonium and uranium ((7.5 -- 50))% Pu were accurate to within 0.15 mg of each element. (auth.)

  15. Characterization of antibody-chelator conjugates: Determination of chelator content by terbium fluorescence titration

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, K.D.; Schnobrich, K.E.; Johnson, D.K. (Abbott Laboratories, Department 90M, Abbott Park, IL (United States))

    1991-01-01

    Fluorescence titrations were performed by adding varying mole ratios of terbium(III) to antibody conjugates formed by benzyl isothiocyanate derivatives of three different polyaminopolycarboxylate chelators (NTA, EDTA, and DTPA) and the results compared to values for average chelator content obtained by cobalt-57 binding assays. For two different murine monoclonal antibodies, the average chelator content obtained by terbium fluorescence titration correlated closely with that measured by the cobalt-57 binding assay. It is concluded that lanthanide fluorescence titrations provide a useful alternative to radiometal binding assays for the determination of chelator content in protein-chelator conjugates.

  16. Characterization of antibody-chelator conjugates: Determination of chelator content by terbium fluorescence titration

    International Nuclear Information System (INIS)

    Brandt, K.D.; Schnobrich, K.E.; Johnson, D.K.

    1991-01-01

    Fluorescence titrations were performed by adding varying mole ratios of terbium(III) to antibody conjugates formed by benzyl isothiocyanate derivatives of three different polyaminopolycarboxylate chelators (NTA, EDTA, and DTPA) and the results compared to values for average chelator content obtained by cobalt-57 binding assays. For two different murine monoclonal antibodies, the average chelator content obtained by terbium fluorescence titration correlated closely with that measured by the cobalt-57 binding assay. It is concluded that lanthanide fluorescence titrations provide a useful alternative to radiometal binding assays for the determination of chelator content in protein-chelator conjugates

  17. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial.

    Science.gov (United States)

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2013-11-01

    Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40-67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22-48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49-70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients

  18. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial

    Science.gov (United States)

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; GrÜnwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2014-01-01

    Summary Background Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. Methods In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. This ongoing trial is registered with ClinicalTrials.gov, number NCT00835978. Findings Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40–67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22–48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49–70) of non

  19. The determination of the enthalpy of formation and the enthalpy increment of Cd0.5 Te0.5 by Calvet calorimetry

    International Nuclear Information System (INIS)

    Agarwal, R.; Venugopal, V.; Sood, D.D.

    1993-01-01

    In the present study the enthalpy of formation of Cd 0.5 Te 0.5 compound at 785 K were determined from the two elements by direct reaction calorimetry using two different types of set-ups. The enthalpy increment values were measured by drop technique in Calvet calorimetry. (author). 3 refs., 4 tabs

  20. Determination of polyhexamethylene biguanide hydrochloride using photometric colloidal titration with crystal violet as a color indicator.

    Science.gov (United States)

    Masadome, Takashi; Miyanishi, Takaaki; Watanabe, Keita; Ueda, Hiroshi; Hattori, Toshiaki

    2011-01-01

    A solution of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was titrated with a standard solution of potassium poly(vinyl sulfate) (PVSK) using crystal violet (CV) as an photometric indicator cation. The end point was detected by a sharp absorbance change due to an abrupt decrease in the concentration of CV. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant existed in the concentration range from 2 to 10 × 10(-6) eq mol L(-1). Back-titration was based on adding an excess amount of PVSK to a sample solution containing CV, which was titrated with a standard solution of poly(diallyldimethylammonium chloride) (PDADMAC). The calibration curve of the PHMB-HCl concentration to the end point volume of the titrant was also linear in the concentration range from 2 to 8 × 10(-6) eq mol L(-1). Both photometric titrations were applied to the determination of PHMB-HCl in a few contact-lens detergents. Back-titration showed a clear end point, but direct titration showed an unclear end point. The results of the back-titration of PHMB-HCl were compared with the content registered in its labels. 2011 © The Japan Society for Analytical Chemistry

  1. Hadronic shower development in iron-scintillator tile calorimetry

    Czech Academy of Sciences Publication Activity Database

    Amaral, P.; Amorim, A.; Anderson, K.; Lokajíček, Miloš; Němeček, Stanislav

    2000-01-01

    Roč. 443, - (2000), s. 51-70 ISSN 0168-9002 R&D Projects: GA MPO RP-4210/69 Institutional research plan: CEZ:AV0Z1010920 Keywords : ATLAS Iron-Scintillator * hadron calorimeter * shower parametrisation * calorimetry * computer data analysis Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.964, year: 2000

  2. Optimization of crystals for applications in dual-readout calorimetry

    Czech Academy of Sciences Publication Activity Database

    Akchurin, N.; Bedeschi, F.; Cardini, A.; Carosi, R.; Ciapetti, G.; Fasoli, M.; Ferrari, R.; Franchino, S.; Fraternali, M.; Gaudio, G.; Hauptman, J.; Incagli, M.; Lacava, F.; La Rotonda, L.; Lee, S.; Livan, M.; Meoni, E.; Nikl, Martin; Pinci, D.; Policicchio, A.; Popescu, S.; Scuri, F.; Sill, A.; Susinno, G.; Vandelli, W.; Vedda, A.; Venturelli, T.; Voena, C.; Volobouev, I.; Wigmans, R.

    2010-01-01

    Roč. 621, 1-3 (2010), 212-221 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10100521 Keywords : calorimetry * Cherenkov light * High-Z scintillating crystals Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.142, year: 2010

  3. Optical fibre temperature sensor technology and potential application in absorbed dose calorimetry

    International Nuclear Information System (INIS)

    Allen, P.D.; Hargrave, N.J.

    1992-09-01

    Optical fibre based sensors are proposed as a potential alternative to the thermistors traditionally used as temperature sensors in absorbed dose calorimetry. The development of optical fibre temperature sensor technology over the last ten years is reviewed. The potential resolution of various optical techniques is assessed with particular reference to the requirements of absorbed dose calorimetry. Attention is drawn to other issues which would require investigation before the development of practical optical fibre sensors for this purpose could occur. 192 refs., 5 tabs., 4 figs

  4. Direct calorimetry of free-moving eels with manipulated thyroid status

    Science.gov (United States)

    van Ginneken, Vincent; Ballieux, Bart; Antonissen, Erik; van der Linden, Rob; Gluvers, Ab; van den Thillart, Guido

    2007-02-01

    In birds and mammals, the thyroid gland secretes the iodothyronine hormones of which tetraiodothyronine (T4) is less active than triiodothyronine (T3). The action of T3 and T4 is calorigenic and is involved in the control of metabolic rate. Across all vertebrates, thyroid hormones also play a major role in differentiation, development and growth. Although the fish thyroidal system has been researched extensively, its role in thermogenesis is unclear. In this study, we measured overall heat production to an accuracy of 0.1 mW by direct calorimetry in a free-moving European eel ( Anguilla anguilla L.) with different thyroid status. Hyperthyroidism was induced by injection of T3 and T4, and hypothyroidism was induced with phenylthiourea. The results show for the first time at the organismal level, using direct calorimetry, that neither overall heat production nor overall oxygen consumption in eels is affected by hyperthyroidism. Therefore, we conclude that the thermogenic metabolism-stimulating effect of thyroid hormones (TH) is not present with a cold-blooded fish species like the European eel. This supports the concept that TH does not stimulate thermogenesis in poikilothermic species.

  5. [Predictive methods versus clinical titration for the initiation of lithium therapy. A systematic review].

    Science.gov (United States)

    Geeraerts, I; Sienaert, P

    2013-01-01

    When lithium is administered, the clinician needs to know when the lithium in the patient’s blood has reached a therapeutic level. At the initiation of treatment the level is usually achieved gradually through the application of the titration method. In order to increase the efficacy of this procedure several methods for dosing lithium and for predicting lithium levels have been developed. To conduct a systematic review of the publications relating to the various methods for dosing lithium or predicting lithium levels at the initiation of therapy. We searched Medline systematically for articles published in English, French or Dutch between 1966 and April 2012 which described or studied a method for dosing lithium or for predicting the lithium level reached following a specific dosage. We screened the reference lists of relevant articles in order to locate additional papers. We found 38 lithium prediction methods, in addition to the clinical titration method. These methods can be divided into two categories: the ‘a priori’ methods and the ‘test-dose’ methods, the latter requiring the administration of a test dose of lithium. The lithium prediction methods generally achieve a therapeutic blood level faster than the clinical titration method, but none of the methods achieves convincing results. On the basis of our review, we propose that the titration method should be used as the standard method in clinical practice.

  6. Titration of uranium trace amounts in waters environment

    International Nuclear Information System (INIS)

    Larabi-Gruet, N.; Ithurbide, A.; Poulesquen, A.; Beaucaire, C.; Peulon, S.; Chausse, A.

    2007-01-01

    In the framework of studies concerning the uranium migration in soils and rocks, it seems necessary to quantify the uranium(VI) dissolved in solution. In the environmental conditions, the uranium(VI) is present at trace amounts. The most adapted method to this study and easy to carry out is the Adsorptive Stripping Voltammetry. By addition of a compound (ligand) with a reducing and strong complexing power, the uranium(VI) present in solution is reduced into a U(VI)-ligand complex. This specie is then oxidized and adsorbed on the mercury droplet where an electrolytic pre-concentration of the element to determine the quantity of is carried out. At last, a cathodic re-dissolution of the specie adsorbed in the U(IV)-ligand complex is carried out. The chosen analytical method is the differential impulsional voltammetry. With this method, it is possible to quantify low electro-active species quantities (sensitivity ∼25 ppt (10 -10 mol.L -1 ) for the uranium). This titration method in solution has been optimized, at first, in a non complexing medium. Then, the uranium in solution has been titrated in media whose composition has been progressively complexed (additions of CO 3 2- , SO 4 2- , Cl - ..) for being at last representative of the environmental interstitial waters. At last, this study has been carried out too by ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) in order to compare the analysis sensitivity of these two detection methods. (O.M.)

  7. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    OpenAIRE

    Eva Tavčar; Erika Turk; Samo Kreft

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes p...

  8. Clinical predictors of central sleep apnea evoked by positive airway pressure titration.

    Science.gov (United States)

    Moro, Marilyn; Gannon, Karen; Lovell, Kathy; Merlino, Margaret; Mojica, James; Bianchi, Matt T

    2016-01-01

    Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%-15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management. We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split-night; n=306 two-night). Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG) data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI) ≥5 during split-night PSG (SN-PSG) versus full-night PSG (FN-PSG) titrations. CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients. Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the laboratory setting, even as PSG remains the gold standard for characterizing primary central apnea and TECSA.

  9. Fast Proton Titration Scheme for Multiscale Modeling of Protein Solutions.

    Science.gov (United States)

    Teixeira, Andre Azevedo Reis; Lund, Mikael; da Silva, Fernando Luís Barroso

    2010-10-12

    Proton exchange between titratable amino acid residues and the surrounding solution gives rise to exciting electric processes in proteins. We present a proton titration scheme for studying acid-base equilibria in Metropolis Monte Carlo simulations where salt is treated at the Debye-Hückel level. The method, rooted in the Kirkwood model of impenetrable spheres, is applied on the three milk proteins α-lactalbumin, β-lactoglobulin, and lactoferrin, for which we investigate the net-charge, molecular dipole moment, and charge capacitance. Over a wide range of pH and salt conditions, excellent agreement is found with more elaborate simulations where salt is explicitly included. The implicit salt scheme is orders of magnitude faster than the explicit analog and allows for transparent interpretation of physical mechanisms. It is shown how the method can be expanded to multiscale modeling of aqueous salt solutions of many biomolecules with nonstatic charge distributions. Important examples are protein-protein aggregation, protein-polyelectrolyte complexation, and protein-membrane association.

  10. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    Science.gov (United States)

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  11. Theoretical problems associated with the use of acetic anhydride as a co-solvent for the non-aqueous titration of hydrohalides of organic bases and quaternary ammonium salts.

    Science.gov (United States)

    Völgyi, Gergely; Béni, Szabolcs; Takács-Novák, Krisztina; Görög, Sándor

    2010-01-05

    A potentiometric titration study of organic base hydrohalides and quaternary ammonium salts using perchloric acid as the titrant and a mixture of acetic anhydride and acetic acid as the solvent was carried out and the titration mixture was analysed by NMR in order to clarify the chemistry of the reactions involved. It was found that in contrast to the general belief the formation of acetyl halides and titratable free acetate ion does not take place prior to the titration but NMR spectra proved the formation of acetyl halides in the course of the titration. This observation and the fact that the shape of the titration curves depends on the nature of the hydrohaloic acid bound to the base or of the anion in the quaternary ammonium salts led to the conclusion that the titrating agent is acetyl perchlorate formed in situ during the titration. Equations of the reactions involved in the titration process are shown in the paper.

  12. The Mobile Insulin Titration Intervention (MITI) for Insulin Adjustment in an Urban, Low-Income Population: Randomized Controlled Trial.

    Science.gov (United States)

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-07-17

    Diabetes patients are usually started on a low dose of insulin and their dose is adjusted or "titrated" according to their blood glucose levels. Insulin titration administered through face-to-face visits with a clinician can be time consuming and logistically burdensome for patients, especially those of low socioeconomic status (SES). Given the wide use of mobile phones among this population, there is the potential to use short message service (SMS) text messaging and phone calls to perform insulin titration remotely. The goals of this pilot study were to (1) evaluate if our Mobile Insulin Titration Intervention (MITI) intervention using text messaging and phone calls was effective in helping patients reach their optimal insulin glargine dose within 12 weeks, (2) assess the feasibility of the intervention within our clinic setting and patient population, (3) collect data on the cost savings associated with the intervention, and (4) measure patient satisfaction with the intervention. This was a pilot study evaluating an intervention for patients requiring insulin glargine titration in the outpatient medical clinic of Bellevue Hospital Center in New York City. Patients in the intervention arm received weekday SMS text messages from a health management platform requesting their fasting blood glucose values. The clinic's diabetes nurse educator monitored the texted responses on the platform website each weekday for alarm values. Once a week, the nurse reviewed the glucose values, consulted the MITI titration algorithm, and called patients to adjust their insulin dose. Patients in the usual care arm continued to receive their standard clinic care for insulin titration. The primary outcome was whether a patient reached his/her optimal insulin glargine dose within 12 weeks. A total of 61 patients consented and were randomized into the study. A significantly greater proportion of patients in the intervention arm reached their optimal insulin glargine dose than patients in

  13. Potentiometric Measurement of Transition Ranges and Titration Errors for Acid/Base Indicators

    Science.gov (United States)

    Flowers, Paul A.

    1997-07-01

    Sophomore analytical chemistry courses typically devote a substantial amount of lecture time to acid/base equilibrium theory, and usually include at least one laboratory project employing potentiometric titrations. In an effort to provide students a laboratory experience that more directly supports their classroom discussions on this important topic, an experiment involving potentiometric measurement of transition ranges and titration errors for common acid/base indicators has been developed. The pH and visually-assessed color of a millimolar strong acid/base system are monitored as a function of added titrant volume, and the resultant data plotted to permit determination of the indicator's transition range and associated titration error. Student response is typically quite positive, and the measured quantities correlate reasonably well to literature values.

  14. Calorimetry exchange program annual data report for 1992

    International Nuclear Information System (INIS)

    Barnett, T.M.

    1992-01-01

    The goals of the Calorimetry Sample Exchange Program are: discuss measurement differences; review and improve analytical measurements and methods; discuss new measurement capabilities; provide data to DOE on measurement capabilities to evaluate shipper-receiver differences; provide characterized or standard materials as necessary for exchange participants; and provide a measurement control program for plutonium analysis. A sample of PuO 2 powder is available at each participating site for NDA measurement, including either or both calorimetry and high-resolution gamma-ray spectroscopy, the elements which are typically combined to provide a calorimetric assay of plutonium. The facilities measure the sample as frequently and to the level of precision which they desire, and then submit the data to the Exchange for analysis. The data report includes summary tables for each measurement and charts showing the performance of each laboratory. Comparisons are made to the accepted values for the exchange sample and to data previously reported by that laboratory. This information is presented, in the form of quarterly and annual reports, intended for use by Exchange participants in measurement control programs, or to indicate when bias corrections may be appropriate. No attempt, however, has been made to standardize methods or frequency of data collection, calibration, or operating procedures. Direct comparisons between laboratories may, therefore, be misleading since data have not been collected to the same precision or for the same time periods. A meeting of the participants of the Calorimetry Exchange is held annually at EG ampersand G Mound Applied Technologies. The purposes of this meeting are to discuss measurement differences, problems, and new measurement capabilities, and to determine the additional activities needed to fulfill the goals of the Exchange. This document provides data for 1992

  15. A knowledge based advisory system for acid/base titrations in non-aqueous solvents

    NARCIS (Netherlands)

    Bos, M.; van der Linden, W.E.

    1996-01-01

    A computer program was developed that could advice on the choice of solvent and titrant for acid/base titrations in nonaqueous media. It is shown that the feasibility of a titration in a given solvent can be calculated from solvent properties and intrinsic acid/base properties of the sample

  16. pH and Titratable Acidity of different Cough Syrups in Nigeria ...

    African Journals Online (AJOL)

    Background: Cough linctuses are liquid oral medicines widely used in children to treat cough and related conditions. Some of their constituents are acidic and dental erosive. Objectives: This in vitro study aimed to evaluate the endogenous pH and titratable acidity of Nigerian cough syrups and also determine their erosive ...

  17. Effects of pH, titratable acidity and calcium concentration of non ...

    African Journals Online (AJOL)

    It has also been reported that experimental addition of calcium in beverages can reduce the progression of erosion. This study was carried out to investigate effects the of pH, titratable acidity and calcium concentration of non alcoholic carbonated beverages on enamel erosion of extracted human premolar teeth. Method: ...

  18. The Davies-Gray titration for the assay of uranium in nuclear materials: a performance study

    International Nuclear Information System (INIS)

    Bickel, M.

    1997-01-01

    An interlaboratory comparison in two phases was organized to assess the precision and accuracy concerning the assay of uranium in nuclear materials by the potentiometric titration method. This contribution presents the results of this exercise in terms of method performance. Variations to be expected between different laboratories and within a single laboratory are estimated. In general, the method proved again very reliable. (orig.)

  19. Potentiometric Titrations for Measuring the Capacitance of Colloidal Photodoped ZnO Nanocrystals.

    Science.gov (United States)

    Brozek, Carl K; Hartstein, Kimberly H; Gamelin, Daniel R

    2016-08-24

    Colloidal semiconductor nanocrystals offer a unique opportunity to bridge molecular and bulk semiconductor redox phenomena. Here, potentiometric titration is demonstrated as a method for quantifying the Fermi levels and charging potentials of free-standing colloidal n-type ZnO nanocrystals possessing between 0 and 20 conduction-band electrons per nanocrystal, corresponding to carrier densities between 0 and 1.2 × 10(20) cm(-3). Potentiometric titration of colloidal semiconductor nanocrystals has not been described previously, and little precedent exists for analogous potentiometric titration of any soluble reductants involving so many electrons. Linear changes in Fermi level vs charge-carrier density are observed for each ensemble of nanocrystals, with slopes that depend on the nanocrystal size. Analysis indicates that the ensemble nanocrystal capacitance is governed by classical surface electrical double layers, showing no evidence of quantum contributions. Systematic shifts in the Fermi level are also observed with specific changes in the identity of the charge-compensating countercation. As a simple and contactless alternative to more common thin-film-based voltammetric techniques, potentiometric titration offers a powerful new approach for quantifying the redox properties of colloidal semiconductor nanocrystals.

  20. Protofit: A program for determining surface protonation constants from titration data

    Science.gov (United States)

    Turner, Benjamin F.; Fein, Jeremy B.

    2006-11-01

    Determining the surface protonation behavior of natural adsorbents is essential to understand how they interact with their environments. ProtoFit is a tool for analysis of acid-base titration data and optimization of surface protonation models. The program offers a number of useful features including: (1) enables visualization of adsorbent buffering behavior; (2) uses an optimization approach independent of starting titration conditions or initial surface charge; (3) does not require an initial surface charge to be defined or to be treated as an optimizable parameter; (4) includes an error analysis intrinsically as part of the computational methods; and (5) generates simulated titration curves for comparison with observation. ProtoFit will typically be run through ProtoFit-GUI, a graphical user interface providing user-friendly control of model optimization, simulation, and data visualization. ProtoFit calculates an adsorbent proton buffering value as a function of pH from raw titration data (including pH and volume of acid or base added). The data is reduced to a form where the protons required to change the pH of the solution are subtracted out, leaving protons exchanged between solution and surface per unit mass of adsorbent as a function of pH. The buffering intensity function Qads* is calculated as the instantaneous slope of this reduced titration curve. Parameters for a surface complexation model are obtained by minimizing the sum of squares between the modeled (i.e. simulated) buffering intensity curve and the experimental data. The variance in the slope estimate, intrinsically produced as part of the Qads* calculation, can be used to weight the sum of squares calculation between the measured buffering intensity and a simulated curve. Effects of analytical error on data visualization and model optimization are discussed. Examples are provided of using ProtoFit for data visualization, model optimization, and model evaluation.

  1. Acid-base titrations using microfluidic paper-based analytical devices.

    Science.gov (United States)

    Karita, Shingo; Kaneta, Takashi

    2014-12-16

    Rapid and simple acid-base titration was accomplished using a novel microfluidic paper-based analytical device (μPAD). The μPAD was fabricated by wax printing and consisted of ten reservoirs for reaction and detection. The reaction reservoirs contained various amounts of a primary standard substance, potassium hydrogen phthalate (KHPth), whereas a constant amount of phenolphthalein was added to all the detection reservoirs. A sample solution containing NaOH was dropped onto the center of the μPAD and was allowed to spread to the reaction reservoirs where the KHPth neutralized it. When the amount of NaOH exceeded that of the KHPth in the reaction reservoirs, unneutralized hydroxide ion penetrated the detection reservoirs, resulting in a color reaction from the phenolphthalein. Therefore, the number of the detection reservoirs with no color change determined the concentration of the NaOH in the sample solution. The titration was completed within 1 min by visually determining the end point, which required neither instrumentation nor software. The volumes of the KHPth and phenolphthalein solutions added to the corresponding reservoirs were optimized to obtain reproducible and accurate results for the concentration of NaOH. The μPADs determined the concentration of NaOH at orders of magnitude ranging from 0.01 to 1 M. An acid sample, HCl, was also determined using Na2CO3 as a primary standard substance instead of KHPth. Furthermore, the μPAD was applicable to the titrations of nitric acid, sulfuric acid, acetic acid, and ammonia solutions. The μPADs were stable for more than 1 month when stored in darkness at room temperature, although this was reduced to only 5 days under daylight conditions. The analysis of acidic hot spring water was also demonstrated in the field using the μPAD, and the results agreed well with those obtained by classic acid-base titration.

  2. A quantitative mechanistic description of Ni, Zn and Ca sorption on Na-Montmorillonite. Part I: Physico-chemical characterisation and titration measurements

    International Nuclear Information System (INIS)

    Baeyens, B.; Bradbury, M.H.

    1995-07-01

    The work presented in this report is primarily concerned with characterisation studies and titration measurements on conditioned Na-montmorillonite. The starting material, SWy-1 Na-montmorillonite (Crook County, Wyoming, USA), contains background metal impurities, soluble salts and sparingly soluble minerals which can influence titration and sorption measurements and thereby lead to difficulties in the interpretation of the data. A conditioning procedure is described which yielded a purified clay material in the homoionic sodium form with a particle size 4 . The reasons for choosing a batch method, coupled with back titration of the supernatant solutions, instead of a continuous procedure, are fully discussed. Chemical analyses data for the supernatant solutions are presented in detail. The influence of background impurities, not removed by the conditioning, and cation exchange processes on the form of the titration curves were investigates. Net Na-montmorillonite titration curves at two different ionic strengths were derived which are considered to reflect only the acid/base behaviour of ≡SOH type surface sites. The acid end point in the titration data was used to estimate an ≡SOH site capacity of 0.08 moles per kg conditioned Na-montmorillonite. (author) 8 figs., 19 tabs., refs

  3. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts.

    Science.gov (United States)

    Doi, K

    1980-11-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDTA has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, DeltaH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at mu --> 0 and mu = 0.5 (NaClO(4)), respectively. The -DeltaH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni.

  4. Optical ph sensing material prepared from doped sol-gel film for use in acid-base titration

    Directory of Open Access Journals (Sweden)

    Musa Ahmad

    2017-11-01

    Full Text Available An optical pH sensing material has been prepared in this study by using sol-gel technique. Bromothymol blue, bromophenol blue and thymol blue were chosen in this study as acidbase indicators for strong acid-strong base, strong acid-weak base and weak acid-strong base titration, respectively. The results show that these indicators could be successfully entrapped inside the sol-gel film and still maintain its chemical behaviour as in solution. The entrapped acid-base indicators respond well to any pH changes and could be used to determine the end-point of the acid-base titration.

  5. Acid Rain Analysis by Standard Addition Titration.

    Science.gov (United States)

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  6. A General Simulator for Acid-Base Titrations

    Science.gov (United States)

    de Levie, Robert

    1999-07-01

    General formal expressions are provided to facilitate the automatic computer calculation of acid-base titration curves of arbitrary mixtures of acids, bases, and salts, without and with activity corrections based on the Davies equation. Explicit relations are also given for the buffer strength of mixtures of acids, bases, and salts.

  7. The acid-base titration of montmorillonite

    Science.gov (United States)

    Bourg, I. C.; Sposito, G.; Bourg, A. C.

    2003-12-01

    Proton binding to clay minerals plays an important role in the chemical reactivity of soils (e.g., acidification, retention of nutrients or pollutants). If should also affect the performance of clay barriers for waste disposal. The surface acidity of clay minerals is commonly modelled empirically by assuming generic amphoteric surface sites (>SOH) on a flat surface, with fitted site densities and acidity constant. Current advances in experimental methods (notably spectroscopy) are rapidly improving our understanding of the structure and reactivity of the surface of clay minerals (arrangement of the particles, nature of the reactive surface sites, adsorption mechanisms). These developments are motivated by the difficulty of modelling the surface chemistry of mineral surfaces at the macro-scale (e.g., adsorption or titration) without a detailed (molecular-scale) picture of the mechanisms, and should be progressively incorporated into surface complexation models. In this view, we have combined recent estimates of montmorillonite surface properties (surface site density and structure, edge surface area, surface electrostatic potential) with surface site acidities obtained from the titration of alpha-Al2O3 and SiO2, and a novel method of accounting for the unknown initial net proton surface charge of the solid. The model predictions were compared to experimental titrations of SWy-1 montmorillonite and purified MX-80 bentonite in 0.1-0.5 mol/L NaClO4 and 0.005-0.5 mol/L NaNO3 background electrolytes, respectively. Most of the experimental data were appropriately described by the model after we adjusted a single parameter (silanol sites on the surface of montmorillonite were made to be slightly more acidic than those of silica). At low ionic strength and acidic pH the model underestimated the buffering capacity of the montmorillonite, perhaps due to clay swelling or to the interlayer adsorption of dissolved aluminum. The agreement between our model and the experimental

  8. Binding of the biogenic polyamines to deoxyribonucleic acids of varying base composition: base specificity and the associated energetics of the interaction.

    Directory of Open Access Journals (Sweden)

    Ayesha Kabir

    Full Text Available BACKGROUND: The thermodynamics of the base pair specificity of the binding of the polyamines spermine, spermidine, putrescine, and cadaverine with three genomic DNAs Clostridium perfringens, 27% GC, Escherichia coli, 50% GC and Micrococcus lysodeikticus, 72% GC have been studied using titration calorimetry and the data supplemented with melting studies, ethidium displacement and circular dichroism spectroscopy results. METHODOLOGY/PRINCIPAL FINDINGS: Isothermal titration calorimetry, differential scanning calorimetry, optical melting studies, ethidium displacement, circular dichroism spectroscopy are the various techniques employed to characterize the interaction of four polyamines, spermine, spermidine, putersine and cadaverine with the DNAs. Polyamines bound stronger with AT rich DNA compared to the GC rich DNA and the binding varied depending on the charge on the polyamine as spermine>spermidine >putrescine>cadaverine. Thermodynamics of the interaction revealed that the binding was entropy driven with small enthalpy contribution. The binding was influenced by salt concentration suggesting the contribution from electrostatic forces to the Gibbs energy of binding to be the dominant contributor. Each system studied exhibited enthalpy-entropy compensation. The negative heat capacity changes suggested a role for hydrophobic interactions which may arise due to the non polar interactions between DNA and polyamines. CONCLUSION/SIGNIFICANCE: From a thermodynamic analysis, the AT base specificity of polyamines to DNAs has been elucidated for the first time and supplemented by structural studies.

  9. Laboratory Automatic Titration of Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    2001-01-01

    .... The analytical chemistry literature lacks an adequate automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric acids...

  10. A titration model for evaluating calcium hydroxide removal techniques

    Directory of Open Access Journals (Sweden)

    Mark PHILLIPS

    2015-02-01

    Full Text Available Objective Calcium hydroxide (Ca(OH2 has been used in endodontics as an intracanal medicament due to its antimicrobial effects and its ability to inactivate bacterial endotoxin. The inability to totally remove this intracanal medicament from the root canal system, however, may interfere with the setting of eugenol-based sealers or inhibit bonding of resin to dentin, thus presenting clinical challenges with endodontic treatment. This study used a chemical titration method to measure residual Ca(OH2 left after different endodontic irrigation methods. Material and Methods Eighty-six human canine roots were prepared for obturation. Thirty teeth were filled with known but different amounts of Ca(OH2 for 7 days, which were dissolved out and titrated to quantitate the residual Ca(OH2 recovered from each root to produce a standard curve. Forty-eight of the remaining teeth were filled with equal amounts of Ca(OH2 followed by gross Ca(OH2 removal using hand files and randomized treatment of either: 1 Syringe irrigation; 2 Syringe irrigation with use of an apical file; 3 Syringe irrigation with added 30 s of passive ultrasonic irrigation (PUI, or 4 Syringe irrigation with apical file and PUI (n=12/group. Residual Ca(OH2 was dissolved with glycerin and titrated to measure residual Ca(OH2 left in the root. Results No method completely removed all residual Ca(OH2. The addition of 30 s PUI with or without apical file use removed Ca(OH2 significantly better than irrigation alone. Conclusions This technique allowed quantification of residual Ca(OH2. The use of PUI (with or without apical file resulted in significantly lower Ca(OH2 residue compared to irrigation alone.

  11. A Geochemical Reaction Model for Titration of Contaminated Soil and Groundwater at the Oak Ridge Reservation

    Science.gov (United States)

    Zhang, F.; Parker, J. C.; Gu, B.; Luo, W.; Brooks, S. C.; Spalding, B. P.; Jardine, P. M.; Watson, D. B.

    2007-12-01

    This study investigates geochemical reactions during titration of contaminated soil and groundwater at the Oak Ridge Reservation in eastern Tennessee. The soils and groundwater exhibits low pH and high concentrations of aluminum, calcium, magnesium, manganese, various trace metals such as nickel and cobalt, and radionuclides such as uranium and technetium. The mobility of many of the contaminant species diminishes with increasing pH. However, base additions to increase pH are strongly buffered by various precipitation/dissolution and adsorption/desorption reactions. The ability to predict acid-base behavior and associated geochemical effects is thus critical to evaluate remediation performance of pH manipulation strategies. This study was undertaken to develop a practical but generally applicable geochemical model to predict aqueous and solid-phase speciation during soil and groundwater titration. To model titration in the presence of aquifer solids, an approach proposed by Spalding and Spalding (2001) was utilized, which treats aquifer solids as a polyprotic acid. Previous studies have shown that Fe and Al-oxyhydroxides strongly sorb dissolved Ni, U and Tc species. In this study, since the total Fe concentration is much smaller than that of Al, only ion exchange reactions associated with Al hydroxides are considered. An equilibrium reaction model that includes aqueous complexation, precipitation, ion exchange, and soil buffering reactions was developed and implemented in the code HydroGeoChem 5.0 (HGC5). Comparison of model results with experimental titration curves for contaminated groundwater alone and for soil- water systems indicated close agreement. This study is expected to facilitate field-scale modeling of geochemical processes under conditions with highly variable pH to develop practical methods to control contaminant mobility at geochemically complex sites.

  12. FLUKA studies of hadron-irradiated scintillating crystals for calorimetry at the High-Luminosity LHC

    CERN Document Server

    Quittnat, Milena Eleonore

    2015-01-01

    Calorimetry at the High-Luminosity LHC (HL-LHC) will be performed in a harsh radiation environment with high hadron fluences. The upgraded CMS electromagnetic calorimeter design and suitable scintillating materials are a focus of current research. In this paper, first results using the Monte Carlo simulation program FLUKA are compared to measurements performed with proton-irradiated LYSO, YSO and cerium fluoride crystals. Based on these results, an extrapolation to the behavior of an electromagnetic sampling calorimeter, using one of the inorganic scintillators above as an active medium, is performed for the upgraded CMS experiment at the HL-LHC. Characteristic parameters such as the induced ambient dose, fluence spectra for different particle types and the residual nuclei are studied, and the suitability of these materials for a future calorimeter is surveyed. Particular attention is given to the creation of isotopes in an LYSO-tungsten calorimeter that might contribute a prohibitive background to the measu...

  13. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    International Nuclear Information System (INIS)

    Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.

    2017-01-01

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration was determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.

  14. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, Daniel H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-23

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration was determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.

  15. Inherent limitations of fixed time servo-controlled radiometric calorimetry

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Duff, M.F.; Lemming, J.F.

    1987-01-01

    There has been some interest in low precision, short run time calorimetry measurements. This type of calorimetry measurement has been proposed for use when high precision measurements are not required, for example, to screen scrap containers to determine if there is enough material to be measured more accurately of for confirmatory measurements that only require low precision results. The equipment needed to make these measurements is a servo-controlled calorimeter with a sample preequilibration bath. The preequilibration bath temperature is set to the internal temperature of the calorimeter running at a fixed servo-controlled wattage level. The sample power value is determined at a fixed time form the sample loading into the calorimeter. There are some limitations and areas of uncertainties in the use of data obtained by this method. Data collected under controlled conditions demonstrate the limitations. Sample packaging, preequilibration time, and item wattage were chosen as the variables most likely to be encountered in a plant environment

  16. Inherent limitations of fixed-time, servo-controlled radiometric calorimetry

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Lemming, J.F.; Duff, M.F.

    1987-01-01

    Interest has been shown in using fixed-time, servo-controlled calorimetry to shorten the measurement times for certain samples that require low precision values (3 to 5%). This type of calorimeter measurement could be particularly useful for screening scrap samples to determine whether there is a need for a more accurate measurement or for certain confirmatory measurements for which low precision numbers are sufficient. The equipment required for this type of measurement is a servo-controlled calorimeter and a preconditioning unit. Samples to be measured are placed in the preconditioning unit, which is maintained at the internal temperature of the calorimeter. The power value for the sample is determined at a fixed time after loading into the calorimeter, for example, 30 min. When a calorimeter is operated using a fixed cutoff time, there are additional sources of uncertainty that need to be considered. The major factors affecting the uncertainty of the calorimetry power values are discussed. 2 refs., 4 figs

  17. Using Spreadsheets to Produce Acid-Base Titration Curves.

    Science.gov (United States)

    Cawley, Martin James; Parkinson, John

    1995-01-01

    Describes two spreadsheets for producing acid-base titration curves, one uses relatively simple cell formulae that can be written into the spreadsheet by inexperienced students and the second uses more complex formulae that are best written by the teacher. (JRH)

  18. Kinetics of Enzymatic High-Solid Hydrolysis of Lignocellulosic Biomass Studied by Calorimetry

    DEFF Research Database (Denmark)

    Olsen, Søren Nymand; Rasmussen, Erik Lumby; McFarland, K.C.

    2011-01-01

    analysis of the interrelationships of enzyme load and the rate, time, and extent of the reaction. The results suggest that the hydrolysis rate of pretreated corn stover is limited initially by available attack points on the substrate surface (conversion) but becomes proportional to enzyme dosage......Enzymatic hydrolysis of high-solid biomass (>10% w/w dry mass) has become increasingly important as a key step in the production of second-generation bioethanol. To this end, development of quantitative real-time assays is desirable both for empirical optimization and for detailed kinetic analysis...... rate with a detection limit of about 500 pmol glucose s−1. Hence, calorimetry is shown to be a highly sensitive real-time method, applicable for high solids, and independent on the complexity of the substrate. Dose–response experiments with a typical cellulase cocktail enabled a multidimensional...

  19. Determination of uranium by a gravimetric-volumetric titration method

    International Nuclear Information System (INIS)

    Krtil, J.

    1998-01-01

    A volumetric-gravimetric modification of a method for the determination of uranium based on the reduction of uranium to U (IV) in a phosphoric acid medium and titration with a standard potassium dichromate solution is described. More than 99% of the stoichiometric amount of the titrating solution is weighed and the remainder is added volumetrically by using the Mettler DL 40 RC Memotitrator. Computer interconnected with analytical balances collects continually the data on the analyzed samples and evaluates the results of determination. The method allows to determine uranium in samples of uranium metal, alloys, oxides, and ammonium diuranate by using aliquot portions containing 30 - 100 mg of uranium with the error of determination, expressed as the relative standard deviation, of 0.02 - 0.05%. (author)

  20. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts

    International Nuclear Information System (INIS)

    Doi, K.

    1980-01-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDT has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, ΔH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at μ → 0 and μ = 0.5 (NaClO 4 ), respectively. The -ΔH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni. (author)

  1. Thermometric titration of acids in pyridine.

    Science.gov (United States)

    Vidal, R; Mukherjee, L M

    1974-04-01

    Thermometric titration of HClO(4), HI, HNO(3), HBr, picric acid o-nitrobenzoic acid, 2,4- and 2,5-dinitrophenol, acetic acid and benzoic acid have been attempted in pyridine as solvent, using 1,3-diphenylguanidine as the base. Except in the case of 2,5-dinitrophenol, acetic acid and benzoic acid, the results are, in general, reasonably satisfactory. The approximate molar heats of neutralization have been calculated.

  2. Determination of nitric acid in highly radioactive solutions by the method of coulometric titration

    International Nuclear Information System (INIS)

    Gromov, V.S.; Kuperman, A.Ya.; Smirnov, Yu.A.

    1988-01-01

    A procedure, a cell, and an electronic block have been developed for a long-distance determination of nitric acid in highly radioactive industrial solutions by coulometric titration under hot chamber conditions. A solution of a mixture of ammonium and potassium oxalates was used for the background and anoide electrolytes. This solution prevents the hydrolysis of the metal ions and appreciably decreases the rate of accumulation of the acid in the anode chamber of the cell. Titration with 0.1-0.5 A currents is carried out with internal generation of hydroxyl ions. The cell was prepared from a radiation-resistant and transparent material, poly(methyl methacrylate). The anode and cathode chambers were separated by a cellophane membrane, reinforced by a porous glass filter. By using the electronic coulometric block working together with a pH-meter (EV-74 or I-130) and with an automatic titration block (BAT-15), the titration can be carried out automatically, and the determination results can be obtained in a digital form

  3. Assessment of Knowledge of Self Blood Glucose Monitoring and Extent of Self Titration of Anti-Diabetic Drugs among Diabetes Mellitus Patients - A Cross Sectional, Community Based Study.

    Science.gov (United States)

    Krishnan, V; Thirunavukkarasu, J

    2016-03-01

    Self blood glucose monitoring is an important context of self care in the management of diabetes mellitus. All the guidelines must be followed while performing self blood glucose monitoring and tracking of values is essential to facilitate the physician while titrating the drugs and /or doses of anti diabetes medication. Self titration by patients following self monitoring must be discouraged. To assess the knowledge and practice of self blood glucose monitoring among diabetes patients and extent of self titration of anti diabetes medicines among diabetes patients based on self blood glucose monitoring. This pilot, cross-sectional, observational study was conducted using a validated questionnaire among adult male and female diabetes patients performing self blood glucose monitoring at home. Diabetes patients with complications and juvenile diabetes patients were excluded. Out of 153 patients surveyed, only 37 (24.1%) (20 males, 17 females) patients were aware and have been following self blood glucose monitoring appropriately. About 116 (75.8%) (64 males, 52 females) of patients were devoid of adequate knowledge and did not practice self blood glucose monitoring in a proper way. Ninety eight (64.05%) accepted that they self titrate their anti diabetic medicines based on self monitoring. Self monitoring of blood glucose should be encouraged and patients should be taught importance of following correct steps and tracking of self monitoring by physician or diabetes educator.

  4. Accurate and precise determination of 2-25mg amounts of uranium by means of a special automatic potentiometric titration

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Groen, A.J.P.; Lingerak, W.A.

    1978-01-01

    A precise and accurate potentiometric titration of 2-25 mg of uranium is described. The uranium is reduced to U(IV) according to the method of Eberle et al. [3], and titrated with 0.05 N potassium dichromate, using a platinum indicator electrode. During the sample preparation the walls of the titration vessel are cleaned by centrifugation. To avoid overshoot of the set point a special differentiator is described, that interrupts the titration until equilibrium is reached. The precision of the method is 0.02%, the accuracy is better than 0.04% rel. Each titration takes 5 min. (orig.) [de

  5. A Titration Technique for Demonstrating a Magma Replenishment Model.

    Science.gov (United States)

    Hodder, A. P. W.

    1983-01-01

    Conductiometric titrations can be used to simulate subduction-setting volcanism. Suggestions are made as to the use of this technique in teaching volcanic mechanisms and geochemical indications of tectonic settings. (JN)

  6. Linear titration plot for the determination of boron in the primary coolant of a pressurized water reactor

    International Nuclear Information System (INIS)

    Midgley, D.; Gatford, C.

    1992-01-01

    A linear titration plot method has been devised for the determination of boron as boric acid in partly neutralized solution, such as occurs in the primary coolant of pressurized water reactors. The total boron and the alkali in the sample are determined simultaneously. Although it is not essential to add mannitol in this method, it is more accurate when the solution is saturated with mannitol. Comparisons are made with other modes of titration: Gran plots, first and second differential potentiometric titrations and indicator titrations. None of these gives the total boron directly in partly neutralized solutions. (author)

  7. Optimizing Glycemic Control Through Titration of Insulin Glargine 100 U/mL: A Review of Current and Future Approaches with a Focus on Asian Populations.

    Science.gov (United States)

    Deerochanawong, Chaicharn; Bajpai, Shailendra; Dwipayana, I Made Pande; Hussein, Zanariah; Mabunay, Maria Aileen; Rosales, Reynaldo; Tsai, Shih-Tzer; Tsang, Man Wo

    2017-12-01

    Various data have demonstrated inadequate glycemic control amongst Asians with type 2 diabetes mellitus (T2DM), possibly on account of suboptimal titration of basal insulin-an issue which needs to be further examined. Here we review the available global and Asia-specific data on titration of basal insulin, with a focus on the use of insulin glargine 100 U/mL (Gla-100). We also discuss clinical evidence on the efficacy and safety of titrating Gla-100, different approaches to titration, including some of the latest technological advancements, and guidance on the titration of basal insulin from international and local Asian guidelines. The authors also provide their recommendations for the initiation and titration of basal insulin for Asian populations. Discussion of the data included in this review and in relation to the authors' clinical experience with treating T2DM in Asian patients is also included. Briefly, clinical studies demonstrate the achievement of adequate glycemic control in adults with T2DM through titration of Gla-100. However, studies investigating approaches to titration, specifically in Asian populations, are lacking and need to be conducted. Given that the management of insulin therapy is a multidisciplinary team effort involving endocrinologists, primary care physicians, nurse educators, and patients, greater resources and education targeted at these groups are needed regarding the optimal titration of basal insulin. Technological advancements in the form of mobile or web-based applications for automated dose adjustment can aid different stakeholders in optimizing the dose of basal insulin, enabling a larger number of patients in Asia to reach their target glycemic goals with improved outcomes.

  8. Microchemical analysis of materials based on Y-Ba-Cu by spectrophotometric titration

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.; Zakharov, Eh.K.

    1990-01-01

    A complex method for analysis of superconductor and similar materials on Y-Ba-Cu basis has been developed, which comprises yttrium and copper determination by their indicator spectrophotometric titration by EDTA and/or complexone 4 in the presence of arsenazo 3. The use of complexone 4 is more favourable. Titration is carried out at λ=650 nm. The method has a sufficient accuracy, provides for rapid determination and does not reguire preliminary separation of components

  9. Molecular Weight Measurement of Biobased Furan Polyamides via Non-Aqueous Potentiometric Titration

    Science.gov (United States)

    2013-06-01

    electromagnetic fields, all titrations were completed in a chemical hood, which acted as a Faraday cage (a shield used to blocks external static and...while using DMF as a solvent. Additionally, no Faraday cage was used in the experimental setup, so the titrations were conducted inside the chemical...monomer was becoming more soluble in glacial acetic acid and the amount of chlorobenzene had less of an effect on the solution properties (i.e

  10. Boehm Titration Revisited (Part I: Practical Aspects for Achieving a High Precision in Quantifying Oxygen-Containing Surface Groups on Carbon Materials

    Directory of Open Access Journals (Sweden)

    Jan Schönherr

    2018-04-01

    Full Text Available Practical aspects of the Boehm titration method are evaluated for obtaining reliable results in the quantification of oxygen-containing surface groups in a short time. Analytical criteria such as accuracy, repeatability, precision, and robustness are applied. Oxidized multi-walled carbon nanotubes (MWCNTs are used as the model substance. Different reaction bases (NaHCO3(aq, Na2CO3(aq, NaOH(aq are applied and treatment times are studied. We also show that smaller amounts of carbon material can be reliably analyzed by using an autotitrator combined with a pH electrode. We find that indirect titration with Na2CO3 results in the highest titration precision and accuracy despite the lower base strength compared with NaOH. Therefore, CO2 impurities do not have to be removed and only 7 min is necessary for one titration. The titration error with respect to the proposed method is 0.15% of the aliquot volume. The mixing method during the carbon treatment with bases (stirring, shaking, ultrasound treatment has no influence on the result as long as one allows a few hours for the reaction to complete. Finally, we provide a standard operating procedure for obtaining results with high precision during Boehm titration.

  11. Macromolecular Competition Titration Method: Accessing Thermodynamics of the Unmodified Macromolecule–Ligand Interactions Through Spectroscopic Titrations of Fluorescent Analogs

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J.

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand–macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein–nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein–nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein–nucleic acid interactions, it can generally be applied to any ligand–macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. PMID:21195223

  12. Macromolecular competition titration method accessing thermodynamics of the unmodified macromolecule-ligand interactions through spectroscopic titrations of fluorescent analogs.

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand-macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein-nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein-nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein-nucleic acid interactions, it can generally be applied to any ligand-macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Accuracy and precision of protein–ligand interaction kinetics determined from chemical shift titrations

    International Nuclear Information System (INIS)

    Markin, Craig J.; Spyracopoulos, Leo

    2012-01-01

    NMR-monitored chemical shift titrations for the study of weak protein–ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K D ) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K D value of a 1:1 protein–ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125–138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of 1 H– 15 N 2D HSQC NMR spectra acquired using precise protein–ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k off ). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k off ∼ 3,000 s −1 in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k off from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k off values over a wide range, from 100 to 15,000 s −1 . The validity of line shape analysis for k off values approaching intermediate exchange (∼100 s −1 ), may be facilitated by more accurate K D measurements from NMR

  14. Accuracy and precision of protein-ligand interaction kinetics determined from chemical shift titrations.

    Science.gov (United States)

    Markin, Craig J; Spyracopoulos, Leo

    2012-12-01

    NMR-monitored chemical shift titrations for the study of weak protein-ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K ( D )) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K ( D ) value of a 1:1 protein-ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125-138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of (1)H-(15)N 2D HSQC NMR spectra acquired using precise protein-ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k ( off )). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k ( off ) ~ 3,000 s(-1) in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k ( off ) from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k ( off ) values over a wide range, from 100 to 15,000 s(-1). The validity of line shape analysis for k ( off ) values approaching intermediate exchange (~100 s(-1)), may be facilitated by more accurate K ( D ) measurements

  15. Common Standards of Basal Insulin Titration in T2DM

    Science.gov (United States)

    Arnolds, Sabine; Heise, Tim; Flacke, Frank; Sieber, Jochen

    2013-01-01

    Type 2 diabetes mellitus has become a worldwide major health problem, and the number of people affected is steadily increasing. Thus, not all patients suffering from the disease can be treated by specialized diabetes centers or outpatient clinics, but by primary care physicians. The latter, however, might have time constraints and have to deal with many kinds of diseases or with multimorbid patients, so their focus is not so much on lowering high blood glucose values. Thus, the physicians, as well as the patients themselves, are often reluctant to initiate and adjust insulin therapy, although basal insulin therapy is considered the appropriate strategy after oral antidiabetic drug failure, according to the latest international guidelines. A substantial number of clinical studies have shown that insulin initiation and optimization can be managed successfully by using titration algorithms—even in cases where patients themselves are the drivers of insulin titration. Nevertheless, tools and strategies are needed to facilitate this process in the daily life of both primary health care professionals and patients with diabetes. PMID:23759411

  16. Assessment of two theoretical methods to estimate potentiometric titration curves of peptides: comparison with experiment.

    Science.gov (United States)

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A

    2006-03-09

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH), and dimethyl sulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the electrostatically driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, molecular dynamics (MD) simulations are run with the AMBER force field and the generalized Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethylamine and propylamine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach and the titration curve in water calculated using the MD-based approach have smooth shapes characteristic of the titration of weak multifunctional acids with small differences

  17. Isothermal calorimetry of enzymatic biodiesel reaction

    DEFF Research Database (Denmark)

    Fjerbæk Søtoft, Lene; Westh, Peter; Christensen, Knud Villy

    2010-01-01

      Isothermal calorimetry ITC has been used to investigate enzymatic biodiesel production. The transesterification of rapeseed oil with methanol and ethanol was catalyzed by the immobilized lipase Novozym 435 at 40°C. The ITC-experiments clearly demonstrate the possibilities of investigating complex...... and composition change in the system, the heat of reaction at 40°C for the two systems has been determined to -9.8 ± 0.9 kJ/mole biodiesel formed from rapeseed oil and methanol, and - 9.3 ± 0.7 kJ/mole when rapeseed oil and ethanol is used....

  18. Individualized toxicity-titrated 6-mercaptopurine increments during high-dose methotrexate consolidation treatment of lower risk childhood acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Frandsen, Thomas Leth; Abrahamsson, Jonas; Lausen, Birgitte Frederiksen

    2011-01-01

    This study explored the feasibility and toxicity of individualized toxicity-titrated 6-mercaptopurine (6MP) dose increments during post-remission treatment with High-dose methotrexate (HDM) (5000 mg/m2, ×3) in 38 patients with Childhood (ALL). Patients were increased in steps of 25 mg 6MP/m2 per...... the remaining patients (P = 0·03). This study shows individualized toxicity-titrated 6MP dosing during consolidation is feasible without increased risk of toxicity....

  19. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    Science.gov (United States)

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  20. Raman spectral titration method: an informative technique for studying the complexation of uranyl with uranyl(vi)-DPA/oxalate systems as examples.

    Science.gov (United States)

    Liu, Qian; Zhang, Qianci; Yang, Suliang; Zhu, Haiqiao; Liu, Quanwei; Tian, Guoxin

    2017-10-10

    The Raman band at about 870 cm -1 originating from the symmetric stretch vibration (ν 1 ) of uranyl, UO 2 2+ , has proven to be very informative for investigating the complexation of uranyl using perchlorate or nitrate of known concentration as internal standards. The concentration of uranyl can be conveniently calculated by using the ratio of the directly read band intensities of uranyl and the added reference, ClO 4 - , with a factor of 1.72. While with NO 3 - of concentration lower than 1.8 M as the reference, a factor of 0.85 should be used. Furthermore, with added internal standards, the linear relationship between the Raman intensity and the concentration of the corresponding species is illustrated by the spectral titration of U(vi) with a very strong ligand, dipicolinic acid (DPA); and the application of a spectral titration method with Raman spectroscopy in studying the complexation of uranyl is demonstrated by the titration of U(vi) with oxalate. The stepwise changes in the Raman shift of 18, 17, and 6 cm -1 , corresponding to the three oxalate anions successively bonding to UO 2 2+ , imply that the coordination modes are different. In the 1 : 1 and 1 : 2 ratios of metal to ligand complexes, the oxalate anions bond to the uranyl ion in side-on bidentate mode, but in the 1 : 3 complex the third oxalate bonds in head-on mode, which is much weaker than the first two.